2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
TECHNICAL PUBLICATION
FALCON
- 2013 -
THALES
- CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de la République – B. P. n° 53 - 78401 CHATOU CEDEX - FRANCE
Tel : 33 1 34.80.73.46 Fax : 33 1 34.80.75.95 E-Mail : [email protected]
THALES AVIONICS ELECTRICAL SYSTEMS
2
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
APPLICABLE TECHNICAL PUBLICATION
1. General conditions 2. List of LRU’s 3. Details of evolutions 4. Statement of agreement
3
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
1. GENERAL CONDITIONS CMM : Component Maintenance Manual. TCMS : Technical Characteristics Maintenance Sheet. SB : Service Bulletin. SIL : Service Information Letter.
Technical Publications (CMM/SB/SIL) are available. To obtain the sale conditions, contact your Commercial Contact. Prior to the delivery of a CMM, the customer shall sign a Statement of Agreement.
4
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
2. LIST OF LRU’S THALES vendor code
TAES P/N DESCRIPTION Electronic Rotable Quantity par A/C
F 1 0
F 2 0
F 2 0 - 5
F 2 0 0
F 5 0
F 5 0 E X
F 9 0 0
F 9 0 0 E X
F 2 0 0 0
F0296 12800-2 Alternator R 2 F0296 12800-2-1 Alternator R 2 F0296 12900-6 GCU E 3 F0296 8040A Starter Gen. R 1 1 F0296 8040C Starter Gen. R 1 1 F0296 8060-140 Starter Gen. R 3 3 1 F0296 8060-141 Starter Gen. R 3 3 1 F0296 8060-141-1 Starter Gen. R 2 3 3 1 F0296 8060-150 Starter Gen. R 2 3 3 1 F0296 8060-160 Starter Gen. R 2 3 3 1 F0296 8060-3 Starter Gen. R 3 3 F0296 8060-300 Starter Gen. R 3 3 F0296 8060-320 Starter Gen. R 3 3 F0296 8060-320-1 Starter Gen. R 3 3 F0296 8060-360 Starter Gen. R 3 3 F0296 D22 GCU E 1 1 F0296 D22-010 GCU E 3 F0296 D22-010-1 GCU E 3 F0296 D22-011 GCU E 3 F0296 D22-011-1 GCU E 3 F0296 D22-022 GCU E 3 3 F0296 D22-032 GCU E 3 F0296 D22-04 GCU E 3 3 F0296 D22-041 GCU E 3 3 F0296 D22-04-1 GCU E 3 3 F0296 D22-041-1 GCU E 3 3 F0296 D22-100 GCU E 3 3 F0296 D22-500 GCU E 3 F0296 D22-500-1 GCU E 3 F0296 D22-501 GCU E 3 F0296 D22-501-1 GCU E 3 F0296 D22-600 GCU E 2 3 3
5
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
3. DETAILS OF EVOLUTIONS
ALTERNATOR P/N 12800-2 CMM reference : 24-30-50 Revision 1 : Date of update June, 15th 2000
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
Amendment A Insulation varnish improvement
/ 1995
Amendment B Identification plate location modification
/ 1995
12800-2-1 Asbestos deletion
Mandatory during repair or
overhaul 2000 SB12800-2-24-001
dated 25/03/1999
ALTERNATOR P/N 12800-2-1 CMM reference : 24-30-50 Revision 1 : Date of update June, 15th 2000
Evolution Reason Application In
Productionsince
SB SIL
/ Packaging for Alternator
Recommended for shipment /
SIL12800-2-1-001Rev. 1
dated 14/04/2012
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
6
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
Amendment C
Power bridge corosion protection improvement
Systematically during repair or
overhaul 2005
SB12800-2-1-24-001
dated 25/01/2006
Amendment D Maintainability improvement
During repair if component has to be replaced
2011 SB12800-2-1-24-
002 dated 22/11/2010
GENERATOR CONTROL UNIT P/N 12900-6 CMM reference : 24-30-51 Revision 1 : Date of update April,15th 1998
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment A
Thresholds of currents and overloads limitations
Mandatory during repair 1997 SB12900-24-002
dated 02/12/1997
Amendment B Improvement of reliability
Mandatory during repair 2002
Amendment C Improvement of reliability
Mandatory during repair 2004
Amendment D PMG fuse value modification
Mandatory during repair 2008 SB12900-24-003
dated 17/03/2008
/ To guaranty solder quality
Mandatory during repair 2009 SB12900-6-24-004
dated 26/03/2009
7
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
STARTER GENERATOR P/N 8040A
Evolution Reason Application In
Productionsince
SB SIL
/ / / / / /
STARTER GENERATOR P/N 8040C
Evolution Reason Application In
Productionsince
SB SIL
/ / / / / /
STARTER GENERATOR P/N 8060-140 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ To improve electrical bonding
Recommended / SIL8060-140-001dated 2/10/1989
/ Improvement of reliability Recommended / SIL8060-140-002
dated 1/11/1991
8
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
8060-141 Improvement of ripple voltage level
Mandatory during Overhaul / SIL8060-140-003
dated 15/10/1995
/ Brush check and brush replacement
Recommended / SIL8060-14*-24-001dated 24/10/2003
Amendment A Protection improvement Recommended 1986
Amendment B Improvement of reliability Mandatory 1986
Amendment C Improvement of reliability Mandatory 1987 SB8060-140-24-01
dated 01/05/1987
Amendment D Improvement of reliability Mandatory 1987
Amendment E Improvement of reliability Mandatory 1993
Amendment H Cooling improvement
In case of frame replacement 1999
Amendment J Production improvement
In case of End Bell Housing
repair or replacement
1999
8060-140-1 Asbestos deletion
Mandatory during repair 1999 SB8060-14*-24-002
dated 06/07/1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-1**-24-003 Rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-141 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
9
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush check and brush replacement
Recommended / SIL8060-14*-24-001dated 24/10/2003
Amendment C Cooling improvement
In case of frame replacement 1999
Amendment D Production improvement
In case of End Bell Housing
repair or replacement
1999
8060-141-1 Asbestos deletion
Mandatory during repair 1999 SB8060-14*-24-002
dated 06/07/1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-1**-24-003 Rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-141-1 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush check and brush replacement
Recommended / SIL8060-14*-24-001dated 24/10/2003
Amendment C Cooling improvement
In case of frame replacement 1999
10
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment D Production improvement
In case of End Bell Housing
repair or replacement
1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-1**-24-003 Rev. 2
dated 14/11/2003
Amendment E Improvement of reliability
Mandatory during repair 1999
SB8060-1**-24-005 Rev. 1
dated 10/01/2005
Amendment F Improvement of reliability Recommended 2006 SB8060-1**-24-006
dated 28/04/2006
Amendment G Improvement of reliability Recommended 2006
SB8060-1**-24-007 Rev. 1
dated 03/08/2007
8060-150 Improvement of maintenance
On customer request 2000
SB8060-141-1-24-001
Rev. 1 dated 25/01/2006
STARTER GENERATOR P/N 8060-150 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush bedding procedure Recommended / SIL8060-***-24-001
dated 06/03/2009
11
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
/ Packaging for Statrter Generator
Recommended / SIL8060-***-24-002dated 01/09/2009
Amendment A Residual voltage improvement Recommended 2001
Amendment B Improvement of reliability Recommended 2004
SB8060-1**-24-005 Rev. 1
dated 10/01/2005
Amendment C Improvement of reliability Recommended 2006 SB8060-1**-24-006
dated 28/04/2006
Amendment D Improvement of reliability Recommended 2006
SB8060-1**-24-007 Rev. 1
dated 03/08/2007
8060-160 Improvement of maintenance Recommended 2003
SB8060-150-24-001
dated 30/03/2004
8060-160 Amendment A
Improvement of maintenance Recommended 2003
SB8060-150-24-001
dated 30/03/2004
/ Overhaul procedure
Mandatory during overhaul /
SB8060-1**-24-003 Rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-160 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
12
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
/ Brush bedding procedure Recommended / SIL8060-***-24-001
dated 06/03/2009
/ Packaging for Statrter Generator
Recommendedfor shipment / SIL8060-***-24-002
dated 01/09/2009
Amendment B Improvement of reliability Recommended 2006 SB8060-1**-24-006
dated 28/04/2006
Amendment C Improvement of reliability Recommended 2006
SB8060-1**-24-007 Rev. 1
dated 03/08/2007
STARTER GENERATOR P/N 8060-3 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Improvement of electrical bonding
Recommended / SIL8060-2/300-001
rev. 2 dated 02/10/1989
/ Tightening brush ckeck Recommended /
SIL8060-300/-03-002
dated 01/11/1990
Amendment A Improvement of reliability Recommended 1977
Amendment B Improvement of reliability Recommended 1978
13
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment C Improvement of reliability Recommended 1978
Amendment D Improvement of reliability Recommended 1978
Amendment E Improvement of reliability
On customer request 1978
Amendment F Improvement of reliability Recommended 1978
Amendment G Improvement of reliability Recommended 1978
Amendment H Improvement of reliability Recommended 1978
Amendment J Improvement of reliability Mandatory 1978
Amendment K Improvement of reliability Mandatory 1979
Amendment L Improvement of reliability Mandatory 1979
Amendment M Improvement of reliability Mandatory 1979
Amendment N Improvement of reliability Recommended 1979
Amendment P To increase the reliability Recommended 1981 SB8060-24-001
dated 05/05/1981
Amendment R Improvement of reliability Recommended 1981
Amendment S Improvement of reliability Recommended 1981
Amendment T Improvement of reliability Recommended 1983
Amendment U Improvement of reliability Recommended 1985
Amendment V Improvement of reliability
Recommendedduring repair or
overhaul 1985 SB8060-24-002
dated 01/11/1986
Amendment W Improvement of reliability Recommended 1985
14
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment Y Improvement of insulation Recommended 1987 SB8060-3-24-05
dated 01/05/1987
Amendment Z Improvement of reliability Recommended 1987
8060-300 Improvement of reliability Recommended 1985
SB8060-24-003 rev. 2
dated 02/01/1990
8060-3-1 Asbestos deletion
Mandatory during repair 1998 SB8060-3*-24-001
dated 06/07/1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-3*-24-002 rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-300 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Improvement of electrical bonding
Recommended / SIL8060-2/300-001
rev. 2 dated 02/10/1989
/ Tightening brush ckeck Recommended /
SIL8060-300/-03-002
dated 01/11/1990
8060-320 Improvement of reliability Recommended / SIL8060-300-003
dated 15/07/1995
Amendment A Improvement of insulation Recommended 1987 SB8060-300-24-01
dated 01/05/1987
Amendment B Improvement of reliability Recommended 1987
Amendment C Improvement of reliability Recommended 1993
15
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
8060-300-1 Asbestos deletion
Mandatory during repair 1998 SB8060-3*-24-001
dated 06/07/1999
Amendment F Cooling improvement
In case of frame replacement 1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-3*-24-002 rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-320 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush bedding procedure Recommended / SIL8060-***-24-001
dated 06/03/2009
/ Packaging for Statrter Generator
Recommendedfor shipment / SIL8060-***-24-002
dated 01/09/2009
8060-320-1 Asbestos deletion
Mandatory during repair 1998 SB8060-3*-24-001
dated 06/07/1999
Amendment C Cooling improvement
In case of frame replacement 1999
Amendment D Production improvement
In case of End Bell Housing
repair or replacement
1999
/ Overhaul procedure
Mandatory during overhaul /
SB8060-3*-24-002 rev. 2
dated 14/11/2003
16
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush bedding procedure Recommended / SIL8060-***-24-001
dated 06/03/2009
/ Packaging for Starter Generator
Recommendedfor shipment / SIL8060-***-24-002
dated 01/09/2009
Amendment C Cooling improvement
In case of frame replacement 1999
Amendment D Production improvement
In case of End Bell Housing
repair or replacement
1999
Amendment E Improvement of reliability Recommended 2000
Amendment F Improvement of reliability Recommended 2001
Amendment G Improvement of reliability Recommended 2004
SB8060-3*-24-004 rev. 1
dated 10/01/2005
Amendment H Improvement of reliability Recommended 2006 SB8060-3*-24-005
dated 28/04/2006
Amendment J Improvement of reliability Recommended 2006
SB8060-3*-24-006 rev. 1
dated 04/06/2007
8060-360 Improvement of scheduled maintenance
On customer request 2003
SB8060-320-1-24-001
dated 13/04/2004
8060-360 Amendment A
Improvement of scheduled maintenance
On customer request 2003
SB8060-320-1-24-001
dated 13/04/2004
/ Overhaul procedure
Mandatory during overhaul /
SB8060-3*-24-002 rev. 2
dated 14/11/2003
STARTER GENERATOR P/N 8060-320-1
17
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
STARTER GENERATOR P/N 8060-360 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / SIL24-99-003 dated 05/09/2012
/ Brush bedding procedure Recommended / SIL8060-***-24-001
dated 06/03/2009
/ Packaging for Statrter Generator
Recommendedfor shipment / SIL8060-***-24-002
dated 01/09/2009
Amendment B Improvement of reliability Recommended 2006 SB8060-3*-24-005
dated 28/04/2006
Amendment C Improvement of reliability Recommended 2006
SB8060-3*-24-006 rev. 1
dated 04/06/2007
GENERATOR CONTROL UNIT P/N D22 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment A Improvement of reliability Recommended 1977
Amendment B Improvement of reliability Recommended 1977
Amendment C Improvement of reliability Recommended 1977
18
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment D Improvement of reliability Recommended 1981
Amendment E Improvement of reliability Recommended 1978
Amendment F Improvement of reliability Recommended 1979
Amendment G Improvement of reliability Recommended 1979
SBD22-24-008 rev. 1
dated 01/01/1987
Amendment H Improvement of reliability Recommended 1979
Amendment J Improvement of reliability Recommended 1979
SBD22-24-001 rev. 1
dated 01/01/1986
Amendment K Improvement of reliability Recommended 1983 SBD22-24-003
dated 01/12/1984
D22-010 Improvement of reliability Recommended 1981 SBD22-24-002
dated 01/03/1983
Amendment L Improvement of reliability Recommended 1983
SBD22-24-004 rev. 1
dated 01/03/1986
Amendment M Improvement of reliability Recommended 1986
SBD22-24-007 rev. 1
dated 01/11/1986
D22-011 Amendment M-N-Q-R-S
Improvement of reliability
On customer request 1996
SBD22-24-017 rev. 1
dated 23/09/1996
GENERATOR CONTROL UNIT P/N D22-010 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment K Improvement of reliability Recommended 1983 SBD22-24-003
dated 01/12/1984
19
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment L Improvement of reliability Recommended 1985
Amendment M Improvement of reliability Recommended 1985
SBD22-24-007 rev. 1
dated 01/11/1986
Amendment N Improvement of reliability
Recommendedon repair 1989
Amendment P Improvement of reliability
Recommendedon repair 1990
SBD22-24-010 rev. 1
dated 01/12/1991
Amendment Q Improvement of reliability
Recommendedon repair 1990 SBD22-24-011
dated 01/10/1990
Amendment S Improvement of reliability
Recommendedon repair 1993
D22-010-1 Integration Amendments K-L-M-N-Q-R
Recommended 1990
D22-011 Amendment M-N-Q-S
Improvement of reliability
Recommendedon repair 1997
SBD22-24-017 rev. 1
dated 23/09/1996
GENERATOR CONTROL UNIT P/N D22-010-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment A Improvement of reliability Recommended 1993
Amendment B Improvement of reliability Recommended 1997
20
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
D22-011-1 Improvement of reliability Recommended 1997
SBD22-24-017 rev. 1
dated 23/09/1996
D22-100 Improvement of reliability Recommended 1998 SBD22-24-018
dated 01/09/1998
GENERATOR CONTROL UNIT P/N D22-011 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment T Improvement of reliability Recommended 1996
GENERATOR CONTROL UNIT P/N D22-011-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
21
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment A Improvement of reliability Recommended 1997
D22-100 Improvement of reliability Recommended 1998 SBD22-24-018
dated 01/09/1998
GENERATOR CONTROL UNIT P/N D22-022 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
D22-030 Improvement of reliability Recommended 1980
Amendment H Improvement of reliability Recommended 1980
SBD22-24-001 rev. 1
dated 01/01/1986
Amendment J Improvement of reliability Recommended 1984 SBD22-24-003
dated 01/12/1984
22
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
GENERATOR CONTROL UNIT P/N D22-032 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment J Improvement of reliability Recommended 1983 SBD22-24-003
dated 01/12/1984
Amendment K Improvement of reliability Recommended 1982
D22-04 Improvement of reliability Recommended 1985
SBD22-24-006 rev. 1
dated 01/01/1987
GENERATOR CONTROL UNIT P/N D22-04 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
23
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment K Improvement of reliability Recommended 1982
Amendment L Improvement of reliability Recommended 1985 SBD22-24-003
dated 01/12/1984
Amendment M Improvement of reliability Recommended 1985
SBD22-24-007 rev; 1
dated 01/11/1986
Amendment N Improvement of reliability Recommended 1991 SBD22-24-013
dated 01/01/1992
Amendment P Improvement of reliability Recommended 1991 SBD22-24-014
dated 01/01/1992
Amendment Q Improvement of reliability Recommended 1991 SBD22-24-016
dated 01/01/1992
D22-04-1 Improvement of reliability Recommended 1991
D22-041 Improvement of reliability Recommended 2003 SBD22-04-24-001
dated 08/07/2004
GENERATOR CONTROL UNIT P/N D22-041 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
24
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
GENERATOR CONTROL UNIT P/N D22-04-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
D22-041-1 Improvement of reliability Recommended 2003 SBD22-04-1-24-001
dated 08/07/2004
GENERATOR CONTROL UNIT P/N D22-041-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
GENERATOR CONTROL UNIT P/N D22-100 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
25
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment A Improvement of reliability Recommended 1999 SBD22-100-24-001
dated 20/01/2009
GENERATOR CONTROL UNIT P/N D22-500 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
/ Modification of test setup Recommended / SILD22-500-001
dated 01/02/1992
Amendment A Improvement of reliability Recommended 1985 SBD22-500-24-004
dated 01/03/1991
Amendment B Improvement of reliability Recommended 1989 SBD22-500-24-005
dated 01/03/1991
Amendment C Improvement of reliability Recommended 1990
SBD22-500-24-001 rev. 1
dated 01/03/1991
Amendment D Improvement of reliability Recommended 1990
SBD22-500-24-002 rev. 1
dated 01/03/1991
Amendment E Improvement of reliability Recommended 1991 SBD22-500-24-006
dated 01/03/1991
26
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
Evolution Reason Application In
Productionsince
SB SIL
Amendment F Improvement of reliability Recommended 1996 SBD22-500-24-009
dated 03/02/2003
D22-500-1 Integration
Amendments A-B-D-E
Recommended 1990 SBD22-500-24-007 dated 15/07/1995
D22-501 Improvement of reliability Recommended 1995 SBD22-500-24-007
dated 15/07/1995
GENERATOR CONTROL UNIT P/N D22-500-1 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
/ Modification of test setup Recommended / SILD22-500-001
dated 01/02/1992
Amendment A Improvement of reliability Recommended 1996 SBD22-500-24-009
dated 03/02/2003
D22-501-1 Improvement of reliability Recommended 1995 SBD22-500-24-007
dated 15/07/1995
D22-600 Improvement of reliability Recommended 1998 SBD22-500-24-008
dated 20/04/1998
27
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
GENERATOR CONTROL UNIT P/N D22-501 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment F Improvement of reliability Recommended 1996 SBD22-500-24-009
dated 03/02/2003
GENERATOR CONTROL UNIT P/N D22-501-1 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
D22-600 Improvement of reliability Recommended 1996 SBD22-500-24-008
dated 20/04/1998
Amendment A Improvement of reliability Recommended 1996 SBD22-500-24-009
dated 03/02/2003
28
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
GENERATOR CONTROL UNIT P/N D22-600 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005
Evolution Reason Application In
Productionsince
SB SIL
/ Order consumables products
Recommended / SIL24-99-001 dated 03/01/2011
/
Electrostatic Discharge Sensitive components
Recommended / SIL24-99-002 dated 09/12/2010
Amendment A Improvement of reliability Recommended 1996 SBD22-600-24-001
dated 20/04/1998
Amendment B Improvement of reliability Recommended 1999 SBD22-600-24-002
dated 20/01/2009
29
2013 TAES – TECHNICAL PUBLICATION
Issued: January 2013
FALCON
4. STATEMENT OF AGREEMENT Statement of Agreement to Terms and Conditions of Sale of Thales Technical Publications Thales Component Maintenance Manual 24-XX-XX is intended solely for use by Company Name. Copying, reproducing or redistribution of this or any Thales Component Maintenance Manual (CMM) or Service Bulletin (SB), to any other party or location is strictly prohibited without Thales prior written consent. Thales retains all intellectual property rights, title and interest in the CMMs and/or SBs provided, including all rights under applicable patents, copyrights, trademarks and trade secrets, and all renewals and extensions thereto. Company Name shall not alter or remove any patent, copyright, trademark, or proprietary rights notice. Agreed to and Accepted by: ____________________________ __________________________ (Print Name) (Title) ____________________________ __________________________ (Signature) (Date)