ez meter-pak meter centers - dds (distributor data solutions) · 2020. 7. 7. · ez meter-pak...

76
Class 4100 EZ Meter-Pak ® Meter Centers EZMH114125 EZM32000CB CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Dimensions and Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Catalog 4100CT0701 2008

Upload: others

Post on 05-Nov-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

Class 4100

EZ Meter-Pak® Meter Centers

EZMH114125

EZM32000CB

CONTENTS

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page

Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Dimensions and Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Catalog4100CT0701

2008

Page 2: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersTable of Contents

2© 2008 Schneider Electric All Rights Reserved 07/2008

Table of Contents

EZ METER-PAK METER CENTERS

UL Listed Meter Center Short Circuit Current Ratings . . . . . . . . . . . . . . . . .4EZM Typical Equipment Lineups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

EZ Meter-Pak (EZM) Meter Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Utility Company Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Equipment Short Circuit Current Ratings . . . . . . . . . . . . . . . . . . . . . . . . .6Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Main Device Ampere Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Main Circuit Breaker Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Main Fusible Switch Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Terminal Box Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Branch Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9125 A Maximum Residential Branch Units . . . . . . . . . . . . . . . . . . . . . . . .9225 A Maximum Residential Branch Units . . . . . . . . . . . . . . . . . . . . . . . .9225 A Maximum Commercial Branch Units . . . . . . . . . . . . . . . . . . . . . .10400 A Maximum Commercial Branch Units . . . . . . . . . . . . . . . . . . . . . .10

Bussed Extension Sections (NEMA Type 3R) . . . . . . . . . . . . . . . . . . . . . .11Bussed Corner Sections for Indoor (NEMA Type 1) Construction Only . . .11

Mounting Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Rotating Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Main Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Single-Phase Branch Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Three-Phase Branch Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Closing Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Closing Plates—Main Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Closing Plates—Branch Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Closing Plates—Main Devices and Branch Units . . . . . . . . . . . . . . . . . .17

Horizontal Cross Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Equipment Grounding Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Visi-Tite® Nut Horizontal Cross Bus Connectors . . . . . . . . . . . . . . . . . .19Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Sealing Rings for Ring-Type Meter Sockets . . . . . . . . . . . . . . . . . . . . . .20Circuit Breaker Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Individual Meter Socket Closing Plates. . . . . . . . . . . . . . . . . . . . . . . . . .20Branch Unit Outer Covers for Tenant Circuit Breaker and Individual Meter Socket Compartments . . . . . . . . . . . . . . . . . . . . . . . . .21Branch Unit Load Neutral Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Branch Unit Load Equipment Grounding Terminals . . . . . . . . . . . . . . . .22

Meter Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23Branch Unit Tenant Circuit Breaker Types and Meter Socket Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23Ring-Type Residential Meter Socket Compartment Standard Features .23

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26125 A Tenant Circuit Breaker Compartment . . . . . . . . . . . . . . . . . . . . . .26225 A Tenant Circuit Breaker Compartment . . . . . . . . . . . . . . . . . . . . . .26Optional Ringless Residential Meter Socket Features . . . . . . . . . . . . . .26400 A Tenant Circuit Breaker Compartment . . . . . . . . . . . . . . . . . . . . . .28Optional Ringless Commercial Meter Socket Features . . . . . . . . . . . . .30

Factory Phase Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Phase Balancing Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

EZM Main Device Types and Configurations . . . . . . . . . . . . . . . . . . . . . . .33Dimensions and Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

Page 3: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

307/2008 © 2008 Schneider Electric All Rights Reserved

NEMA 3R Construction 240 Vac Maximum, for use on AC systems, suitable for use as Service Equipment.Utility Company Requirements: Review local utility requirements to ensure that metering equipment meets their standards.EZ Meter-Pak meter center enclosures meet NEC wire bending requirements, and are designed for wall mounting only (not suitable for floor mounting). All unmetered conductor compartments may be sealed by the utility company.EZ Meter-Pak meter centers have UL Listed short circuit current ratings up to 100 kA at 240 Vac when properly applied. For three-tier series ratings, refer to Data Bulletin 4100DB0301 and Instruction Bulletin 80043-303-19.Suitable incoming services for an EZM main device and available outgoing feeder(s) to downstream panelboards from EZM branch section(s)—Incoming Service to Main Device 120/240 Vac, 1Ø3WAvailable outgoing feeder(s) to downstream panelboards:• 120/240 Vac, 1Ø3W

(four-jaw ring type meter sockets, two-pole circuit breakers)(five-jaw ringless meter sockets, two-pole circuit breakers)

Incoming Service to Main Device 240/120 Vac, 3Ø4W DeltaAvailable outgoing feeder(s) to downstream panelboards:• 120/240 Vac, 1Ø3W (Fed from transformer’s “A-Phase” and

“C-Phase” only.) NOTE: Connection to High-Leg “B-Phase” not permitted for this service.(four-jaw ring type meter sockets, two-pole circuit breakers)(five-jaw ringless meter sockets, two-pole circuit breakers)Standard 3Ø IN/1Ø OUT branch units are not suitable for use on this Delta System. Special branch units are available for this System by adding suffix: “CA” to catalog number (Typical Examples: EZM313125CA, EZM313125XCA, EZM313125CUXCA, EZM314225CA, EZM314225XCA, EZM314225CUXCA, EZM315225CA, EZM314225CUCA, etc.).

• 240/120 Vac, 3Ø4W Delta (seven-jaw meter sockets, three-pole circuit breakers)

Incoming Service to Main Device 208Y/120 Vac, 3Ø4WAvailable outgoing feeder(s) to downstream panelboards:• 120/208 Vac, 1Ø3W (five-jaw meter sockets, two-pole circuit

breakers)• 208Y/120 Vac, 3Ø4W (seven-jaw meter sockets, three-pole

circuit breakers)

Main Devices:• 400, 600 and 800 A main disconnects may be end mounted

with branch units having 800 A or 1200 A continuous horizontal cross bus.

• 1000 and 1200 A main disconnect or terminal box must be center mounted when used with branch devices with main bus rated 800 A continuous.

• 1600 A main disconnect or terminal box must be center mounted.

• 2000 A main disconnect or terminal box must be center mounted and requires use of branch units having 1200 A continuous horizontal cross bus.

• 400, 800 and 1200 A Type EZM-TBU tap boxes supplied with lug landings to meet EUSERC requirements.

Main Circuit Breaker, ratings: 400, 600, 800, 1000, 1200, 1600 and 2000 AMain Fusible Switch, ratings: 400, 600, 800, and 1200 A (1Ø3W only)Main Lugs Terminal Box, ratings: 225, 400, 600, 800, 1200, 1600 and 2000 A

Branch Units:• 125 A and 225 A residential branch units are available

in ring type or ringless type construction and are supplied with 800 A continuous aluminum horizontal cross bus as standard (Example: EZM314125). For optional 1200 A continuous copper horizontal cross bus with aluminum vertical connectors, add suffix “X” to catalog number (Example: EZM314125X). For optional 1200 A continuous all-copper bussing, add suffix “CUX” to catalog number (Example: EZM314125CUX). NOTE: Five-gang 225 A EZM, EZMR and EZMH residential branch units are supplied with 1200 A continuous cross bus as standard, do not add suffix “X” or “CUX” to these units (Examples: EZMR315225 or EZMR315225CU). Plug-in style residential meter sockets are available as ring type EZM without bypass, ringless type EZMR without bypass, and ringless type EZMH with horn bypass.

Tenant circuit breakers must be ordered separately for these branch units. 125 A max. units make use of Type QO, QO-VH or QO-H two-pole tenant circuit breakers (40–125 A). 225 A max. units make use of Type QDP-TM, QBP-TM, QGP-TM and QJP-TM two-pole tenant circuit breakers (70–225 A), and may also make use of two-pole Type QO (40–125 A at 10 kA max.), two-pole Type QO-VH (40–60 A at 100 kA max.), or two-pole Type QO-H (40–60 A at 100 kA max.) tenant circuit breakers.

• 225 A commercial branch units are available in ring type or ringless type construction and are supplied with 1200 A copper horizontal cross bus with aluminum vertical connectors as standard (Example: EZML314225). For optional 1200 A continuous all-copper bussing, add suffix “CU” to catalog number (Example: EZML314225CU). Plug-in style commercial meter sockets are available as ring type EZMT with test block bypass (meets EUSERC requirements), ringless type EZMR without bypass, and ringless type EZML with lever bypass.

225 A max. units make use of type QDP-TM, QBP-TM, QGP-TM and QJP-TM two-pole or three-pole tenant circuit breakers (70– 225 A), and may also make use of two-pole type QO (40–125 A at 10 kA max.), two-pole type QO-VH (40–60 A at 100 kA max.), or two-pole type QO-H (40–60 A at 100 kA max.) tenant circuit breakers.

Note: QO, QO-VH and QO-H tenant circuit breakers used in 225 A branch units require the use of adapter EZM125QOA (purchased separately). • 400 A branch units are available in ringless type

construction only, and are supplied with 1200 A continuous all-copper bussing as standard (Example: EZML332400). These branch units are supplied with factory-installed type DJM tenant circuit breakers that have a field adjustable ampere rating trip setting from 160 A min. to 400 A max. A tamper-evident seal kit is available where needed, order seal kit 29375 (refer to NEC 240-6 [c]). 400 A branch units are available as Type EZML with plug-in style lever bypass type meter sockets, or Type EZMK with bolt-on style with manual bypass type meter sockets.

• Units having 800 A continuous horizontal cross bus WILL CONNECT with units having 1200 A continuous horizontal cross bus.

• Single phase units (three bus bars in horizontal cross bus) WILL NOT CONNECT with three phase units (four bus bars in horizontal cross bus).

For Load Center Three-Tiered Series Ratings used downstream from Metering Equipment, refer to Data Bulletins 4100DB0301 and 2700DB9901.

Page 4: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

4© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers • Review local utility requirements to ensure that metering

equipment meets their standards.• Check local utility to determine available fault current at the

meter center.

• Using the SCCR table:— Select meter center configuration, main lugs only (Six

Disconnect Rule), or remote main, main circuit breaker, or main fusible switch.

— Read down to select SCCR equal to, or greater than desired rating.

— Read across to select branch unit tenant circuit breaker type.— Continue reading across to select EZM main device type.

UL Listed Meter Center Short Circuit Current Ratings (SCCR) Tenant circuit breakers of same frame size having higher AIR values may replace tenant circuit breakers as listed in tables below and maintain the series rating.

Figures

Short Circuit Current Rating

(240 Vac Maximum) a b

EZM Meter Center Overcurrent Protection Devices

EZM Branch Unit Tenant Circuit Breaker Types Available (Branch Unit Amperes max.,

Number of Poles, Tenant Circuit BreakerAmperes Rating Range)

EZM Main Device with Integral Mounted Main, Remote Mounted Main or without an Upstream Mounted Main

(Six Disconnect Rule)

EZ Meter-Pak (Six Disconnect Rule Applications)—See Figure 1

10 kAQO (125 A, 2P, 40–125 A)

400–2000 A Main Lugs Terminal Box (Tenant Circuit Breakers used as Service Disconnects—6 maximum)

QO (225 A, 2P, 40–125 A) d

QB (225 A, 2P or 3P, 70–225 A)

22 kA QO-VH (125 A, 2P, 40–125 A )QO-VH (225 A, 2P, 40–60 A) d

25 kA QD (225 A, 2P or 3P, 70–225 A)

42 kA QOH (125 A, 2P, 40–125 A)QOH (225 A, 2P, 40–60 A) d

65 kA QG (225 A, 2P or 3P, 70–225 A)

100 kA QJ (225 A, 2P or 3P, 70–225 A) c

DJM (400 A, 2P or 3P, 160–400 A) c e

EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure 2

10 kA

QO (125 A, 2P, 40–125 A)

Must be protected by an upstream disconnecting means rated 10 k AIR minimumQO (225 A, 2P, 40–125 A) d

QB (225 A 2P or 3P, 70–225 A)DJM (400 A, 2P or 3P 160–400 A) e

22 kAQO-VH (125 A, 2P, 40–125 A)

Must be protected by an upstream disconnecting means rated 22 k AIR minimumQO-VH (225 A, 2P, 40–60 A) d

DJM (400 A, 2P or 3P, 160–400 A) e

25 kA QD (225 A 2P or 3P, 70–225 A) Must be protected by an upstream disconnecting means rated 25 k AIR minimumDJM (400 A, 2P or 3P, 160–400 A)e

42 kA

QOH (125 A, 2P, 40–125 A)Must be protected by an upstream disconnecting means rated 42 k AIR minimumQOH (225 A, 2P, 40–60 A) d

DJM (400 A, 2P or 3P, 160–400 A) e

QO-VH (125 A, 2P, 40–125 A) Must be protected by a Square D circuit breaker Type LA (400 A max.) or MA (1000 A max.) Rated 42 k AIR minimum QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P or 3P, 70–225 A)

65 kA

QG (225 A 2P or 3P, 70–225 A) Must be protected by an upstream disconnecting means rated 65 k AIR minimumDJM (400 A, 2P or 3P, 160–400 A) e

QO-VH (125 A, 2P, 40–125 A) Must be protected by a Square D circuit breaker Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) rated 65 k AIR minimum QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P or 3P, 70–225 A)

QD (225 A 2P or 3P, 70–225 A) Must be protected by a Square D circuit breaker Type MG (800 A max.), PG (1200 A max.) or RG (2000 A max.) rated 65 k AIR minimum

100 kA

QJ (225 A 2P or 3P, 70–225 A ) c Must be protected by an upstream disconnecting means rated 100 k AIR minimumDJM (400 A 2P or 3P, 160–400 A) c e

QO-VH (125 A, 2P, 40–125 A) Must be protected by an upstream disconnection means with Class R (600 A max.), or Class T (300 Vac, 800 A maximum) fuses.QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P only, 70–225 A) Must be protected by an upstream disconnection means with Class J (600 A max.), Class L (1200 A max.), Class R (600 A max.), Class T (300 Vac, 1200 A max.) or Class T (600 Vac, 800 A maximum) fuses; or protected by a Square D circuit breaker Type MJ (800 A max.), PJ (1200 A max.), PH (1600 A max.) or RJ (2000 A max.) rated 100 k AIR minimum.

QD (225 A 3P only, 70–225 A) c

EZ Meter-Pak—Main Circuit Breaker Applications—See Figure 3

10 kAQO (125 A, 2P, 40–125 A)

400–1600 A EZM Main Device with Type LH (400 A Max.), MH (1000 A max.) or PA (1600 A max.) circuit breaker.

QO (225 A, 2P, 40–125 A) d

QB (225 A 2P or 3P, 70–225 A)

65 kA

QO-VH (125 A, 2P, 40–125 A)QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P or 3P, 70–225 A)DJM (400 A, 2P or 3P, 160–400 A) e

65 kA QD (225 A, 3P, 70–225 A)

1000–1200 A Main Device with catalog number suffix "CBU" supplied with Type MHF circuit breaker.

100 kA

QO-VH (125 A, 2P, 40–125 A)QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P only, 70–225 A)QD (225 A 3P only, 70–225 A) c

DJM (400 A, 2P or 3P, 160–400 A) c e

QD (225 A 2P only, 70–225 A)2000 A EZM Main Device with Type RJ (2000 A) circuit breakerQD (225 A 3P only, 70–225 A) c

DJM (400 A 2P or 3P, 160–400 A) c e

EZ Meter-Pak—Main Fusible Switch Applications—See Figure 3

10 kAQO (125 A, 2P, 40–125 A) 400–800 A EZM Main Device (1Ø or 3Ø) with Class T (300 Vac) fuses installed. 1200 A EZM

Main Device (1Ø only) with Class T (300 Vac) fuses installed.QO (225 A, 2P, 40–125 A) d

QB (225 A 2P or 3P, 70–225 A)

42 kA QO-VH (125 A, 2P, 40–125 A)

1200 A EZM Main Device (1Ø only) with Class T (300 Vac) fuses installed.QO-VH (225 A, 2P, 40–60 A) d

100 kA DJM (400 A, 2P, 160–400 A) e

QD (225 A 2P, 70–225 A)

100 kA

QO-VH (125 A, 2P, 40–125 A)

400–800 A EZM Main Device (1Ø or 3Ø) with Class T (300 Vac) fuses installed.QO-VH (225 A, 2P, 40–60 A) d

QD (225 A 2P, only, 70–225 A)QD (225 A 3P only, 70–225 A) c

DJM (400 A, 2P or 3P, 160–400 A) c e

a Meter center short circuit current rating is equal to the lowest short circuit current rating given in table for any circuit breaker installed in any meter panelboard in the meter center.b Short circuit current rating is measured at the LINE SIDE terminals of the integral mounted or remote mounted main providing overcurrent protection for the EZM metering equipment lineup.c Three-pole only tenant circuit breaker(s) are limited to 208Y/120 Vac maximum.d Requires use of EZM125QOA adapter (order separately). e Supplied with factory installed circuit breaker(s), with an adjustable trip range of 160–400 A.

For three-tier series ratings refer to Data Bulletin 4100DB0301 and Instruction Bulletin 80043-303-19.

LoadCenters

(Main Lugs)

T ransformer

ServiceDisconnects

(6 Max.)

EZM Main Lugs Terminal Box

EZM Branch Units

Figure 1

TenantCircuit

Breakers

LoadCenters

(Main Lugs)Transformer

EZM Main Lugs Terminal Box

EZM Branch Units

Upstream DisconnectionMeans and OvercurrentProtection as required

Figure 2

LoadCenters

(Main Lugs)

Transformer

EZM Circuit Breaker Mainor EZM Main Fusible Switch

TenantCircuit

Breakers

EZM Branch Units

Figure 3

Page 5: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

507/2008 © 2008 Schneider Electric All Rights Reserved

EZM Typical Equipment Lineups

EZM1800TB

EZM114125

Typical Tenant Circuit Breakers

QO2100Two-Pole, Plug-On QO Circuit Breaker

EZM1800CB

EZM114225

EZML311400EZM31600CB

QDP22200TM Two-Pole Circuit Breaker (shown)

DJM32400E20 Circuit Breaker

EZML334225

NOTE: 1600 A main circuit breaker must be center mounted with branch units mounted on both sides.

NOTE: The Q-Frame circuit breaker used with EZM devices comes without line side lugs.

Page 6: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersApplication Data

6© 2008 Schneider Electric All Rights Reserved 07/2008

Application Data

EZ Meter-Pak (EZM) Meter Centers

• Enclosures are indoor/rainproof NEMA Type 3R meter centers for use on ac systems.

• Finish: ANSI gray, baked powder-coat epoxy electrodeposited over cleaned phosphatized steel.

• 240 Vac maximum.

• Suitable for use as service equipment and suitable for use on the line side of service equipment.

• Enclosures meet NEC® wire bending space requirements.

• Designed to be wall mounted only (not suitable for floor mounting).

• All unmetered conductor compartments may be sealed by the utility company.

• EZ Meter-Pak meter centers are UL Listed under File E-10582 and File E-131840.

Utility Company Requirements

Review local utility requirements to ensure that the metering equipment selected meets local standards.

EZ Meter-Pak meter centers, to be complete, must include:

• EZM main device, or terminal box;

• EZM branch section(s), and

• Square D® brand branch circuit breakers (tenant mains).

Equipment Short Circuit Current Ratings

Available up to 100,000 RMS symmetrical amperes. Refer to pages 3 and 4.

Systems

Utility systems suitable for use as an incoming service to an EZM main device:

• System: 120/240 Vac, 1Ø3W

Available incoming service to main device:

120/240 Vac, 1Ø3W

• System: 240/120 Vac, 3Ø4W delta

Available incoming services to main device: 240/120 Vac, 3Ø4W delta 120/240 Vac, 1Ø3W (fed from transformer’s AØ and CØ only).

NOTE: Connection to High-Leg BØ not permitted for this service. Standard 3-phase IN/1-phase OUT branch units are NOT suitable for use on this DELTA System. Special branch units are available for this system by adding suffix "CA" to catalog number (examples: EZM313125CA, EZM314225CA etc.)

• System: 208Y/120 Vac, 3Ø4W

Available incoming services to main device:

120/208 Vac, 1Ø3W or 208Y/120 Vac, 3Ø4W

EZM1800CB

EZM3800FS

EZM1800TB

Page 7: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersApplication Data

707/2008 © 2008 Schneider Electric All Rights Reserved

Services

The following are incoming services for an EZM main device and available outgoing feeder(s) to downstream panelboards from EZM branch section(s):

• 120/240 Vac, 1Ø3W to main device. Available outgoing feeder(s) to downstream panelboards 120/240 Vac, 1Ø3W.

• 120/208 Vac, 1Ø3W to main device (derived from a 208Y/120 Vac, 3Ø4W network). Available outgoing feeder(s) to downstream panelboards 120/208 Vac, 1Ø3W.

• 240/120 Vac, 3Ø4W delta to main device. Available outgoing feeder(s) to downstream panelboards:

— 120/240 Vac, 1Ø3W (fed from transformer’s AØ and CØ only). Special branch units are available for this system by adding suffix “CA” to catalog number, for example: EZM313125CA.

NOTE: Connection to High-Leg BØ not permitted for this service.Standard 3Ø IN/1Ø OUT branch units are not suitable for use on this delta system.

— 240/120 Vac, 3Ø4W delta

• 208Y/120 Vac, 3Ø4W to main device. Available outgoing feeder(s) to downstream panelboards:

— 120/208 Vac, 1Ø3W (Fifth jaw required)

— 208Y/120 Vac, 3Ø4W

EZM314125

EZM114225

EZMR332225

EZML311400

Page 8: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersMain Device Ampere Ratings

8© 2008 Schneider Electric All Rights Reserved 07/2008

Main Device Ampere Ratings

Main Circuit Breaker Ratings

• 400, 600, 800,1000, 1200,1600, and 2000 A combination overhead/underground

• 400, 600, 800, 1000, and 1200 A underground only (meets EUSERC standards)

• 1600 and 2000 A underground only (does not meet EUSERC standards).

Main Fusible Switch Ratings

• 400, 600, and 800 A (1Ø3W and 3Ø4W) and 1200 A (1Ø3W only) combination overhead/underground

• 400, 600, and 800 A (1Ø3W and 3Ø4W) and 1200 A (1Ø3W only) underground only (meets EUSERC standards).

Terminal Box Ratings

225, 400, 600, 800, 1600, and 2000 A combination overhead/underground.

400, 800, and 1200 A underground only (meets EUSERC standards).

Mounting Restrictions for Main Devices:

• 400, 600, and 800 A main disconnects may be end mounted with branch units having 800 or 1200 A continuous horizontal cross bus.

• 1000 and 1200 A main disconnect or terminal box must be center mounted when used with branch devices with main bus rated 800 A continuous.

• 1600 A main disconnect or terminal box must be center mounted.

• 2000 A main disconnect or terminal box must be center mounted and requires use of branch units having 1200 A continuous horizontal cross bus.

• 400, 800, and 1200 A type EZM-TBU tap boxes supplied with lug landings to meet EUSERC standards.

EZM31600CB

EZM1800CBU

EZM32000CBEZM3800FS EZM1800TB

Page 9: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersBranch Units

907/2008 © 2008 Schneider Electric All Rights Reserved

Branch Units

UL Listed meter center short circuit current ratings (RMS symmetrical amperes) are listed on pages 3 and 4.

125 A Maximum Residential Branch Units

• Available in two cross bus configurations: 1Ø IN/1Ø OUT (includes three horizontal cross bus bars), and 3Ø IN/1Ø OUT (includes four horizontal cross bus bars).

• Accepts 40–125 A, two-pole, plug-on type QO, QO-VH, or QOH circuit breakers (order circuit breakers separately).

• Ring-type EZM branch units supplied with four-jaw (1Ø IN units), and with five-jaw (3Ø IN units), 100 A continuous duty rated meter sockets, without bypass (manual slider type bypass kit MM200MB can be ordered separately and field-installed).

• Ringless-type EZMR branch units supplied with five-jaw, 100 A continuous duty rated meter sockets, without bypass (horn type bypass kit MMHB can be ordered separately and field-installed).

• Ringless-type EZMH branch units supplied with five-jaw, 100 A continuous duty rated meter sockets and horn type bypass.

• Supplied with 800 A horizontal main cross bus.

• 1000, 1200, or 1600 A main devices must be center located when used with 125 A branch units with 800 A main cross bus.

• 2000 A main device must be center located when used with 125 A branch units with 1200 A main horizontal cross bus.

225 A Maximum Residential Branch Units

• Available in two cross bus configurations: 1Ø IN/1Ø OUT (includes three horizontal cross bus bars), and 3Ø IN/1Ø OUT (includes four horizontal cross bus bars).

• Accepts 70–225 A, 2-pole, bolt-on type QB, QD, QG or QJ circuit breakers, or with the use of plug-on adapter catalog number EZM125QOA, these units will accept 40–125 A, two-pole plug-on type QO, 40-60 A two-pole plug-on type circuit breakers QO-VH or QOH (order circuit breakers and adapters separately).

• Ring-type EZM branch units supplied with four-jaw (1Ø IN units), and with five-jaw (3Ø IN units), 200 A continuous duty rated meter sockets, without bypass (manual slider type bypass kit MM200MB can be ordered separately and field-installed).

• Ringless-type EZMR branch units supplied with five-jaw, 200 A continuous duty rated meter sockets without bypass (horn type bypass kit MMHB can be ordered separately and field-installed).

• Ringless-type EZMH branch units supplied with five-jaw, 200 A continuous duty rated meter sockets and horn type bypass.

• Two- through four-position units supplied with 800 A horizontal main cross bus and five-position supplied with 1200 A horizontal cross bus.

• 1000, 1200, and 1600 A main device must be center located when used with 225 A branch units with 800 A main horizontal cross bus.

• 2000 A main device must be center located when used with 225 A branch units with 1200 A main horizontal cross bus.

EZM316125

EZM115125

EZMH114125 EZM113125

EZM114225

Page 10: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersBranch Units

10© 2008 Schneider Electric All Rights Reserved 07/2008

225 A Maximum Commercial Branch Units

• Available in two cross bus configurations: 1Ø IN/1Ø OUT (includes three horizontal cross bus bars), 3Ø IN/1Ø OUT, and 3Ø IN/3Ø OUT (includes four horizontal cross bus bars).

• 1Ø OUT branch units accept 70–225 A type QB, QD, QG, and QJ, two-pole, bolt-on circuit breakers (order circuit breakers separately).

• 3Ø OUT branch units accept 70–225 A type QB, QD, QG, and QJ, three-pole, bolt-on circuit breakers (order circuit breakers separately).

• 1Ø OUT ringless-type EZML branch units are supplied with five-jaw, 200 A continuous duty 1Ø meter sockets with lever type bypass.

• 1Ø OUT ring-type EZMT branch units are supplied with five-jaw, 200 A continuous duty 1Ø meter sockets with test block bypass (meets EUSERC standards).

• 3Ø OUT ringless-type EZML branch units are supplied with seven-jaw, 200 A continuous duty 3Ø meter sockets with lever bypass.

• 3Ø OUT ringless-type EZMR branch units are supplied with seven-jaw, 200 A continuous duty 3Ø meter sockets without bypass.

• 3Ø OUT Ring-type EZMT branch units are supplied with seven-jaw, 200 A continuous duty 3Ø meter sockets with test block bypass (meets EUSERC standards).

• Supplied with 1200 A horizontal main cross bus.

• 1600 and 2000 A main devices must be center located when used with 225 A commercial branch units.

400 A Maximum Commercial Branch Units

• Available in two cross bus configurations: 1Ø IN/1Ø OUT (includes three horizontal cross bus bars), and 3Ø IN/1Ø OUT (includes four horizontal cross bus bars).

• 1Ø OUT branch units are supplied with factory-installed 400 A Type DJM two-pole circuit breaker(s). DJM circuit breaker has adjustable trip settings from 160–400 A (seal kit catalog number 29375 available separately).

• 3Ø OUT branch units are supplied with factory-installed 400 A Type DJM three-pole circuit breaker(s). DJM circuit breaker has adjustable trip settings from 160–400 A (seal kit catalog number 29375 available separately).

• Supplied with 1200 A horizontal main cross bus.

• 1600 and 2000 A main devices must be center located when used with 400 A commercial branch units.

EZMR333225

EZML334225

EZMT EZML331400

Page 11: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersBussed Extension Sections (NEMA Type 3R)

1107/2008 © 2008 Schneider Electric All Rights Reserved

Bussed Extension Sections (NEMA Type 3R)Bussed extensions provide separation between enclosures where needed to avoid building obstructions. The bussed extension occupies an area 19.25 in. (489 mm) H x 12.0 in. (304 mm) or 6.0 in. (152 mm) W positioned vertically in line with the horizontal cross bus of main and branch unit enclosures. Extensions provide additional space between the main device and the branch unit where needed to meet local utility requirements. In this case the main device is deeper than the branch unit, and the dimension between the side of the main device and the centerline of the branch unit meter socket is too close to meet minimum “clear space” requirements.

• Bussed extensions are also used with bussed corner sections to provide additional working space in inside corner areas.

• Use EZM1EXT6 (6.0 in.) or EZM1EXT (12.0 in.) wide.

• Use EZM3EXT6 (6.0 in.) or EZM3EXT (12.0 in.) wide.

• Supplied with 1200 A horizontal main cross bus.

• Provisions for padlocking or sealing by the utility.

Bussed Corner Sections for Indoor (NEMA Type 1) Construction Only• Enables mounting of metering enclosures on two adjacent walls.

• NEMA Type 1 construction for use indoors only.

• Designed for “inside and outside corners”.

• Use EZM1CORNER (inside corner) with 1Ø cross bus equipment.

• Use EZM1ELBOW (outside corner) with 1Ø cross bus equipment.

• Use EZM3CORNER (inside corner) with 3Ø cross bus equipment.

• Use EZM3ELBOW (outside corner) with 3Ø cross bus equipment.

• Supplied with 1200 A horizontal main cross bus.

• Provisions for padlocking or sealing by the utility.

Mounting Channel (see page 12)

• EZM main and branch units are each supplied with a wall mounting channel.

• Mounting channel is packed externally to each device on top surface of front cover inside each carton for easy access. Covers do not need to be removed from device to access mounting channel.

Rotating Mounting Brackets (see page 12)

• EZM sections are equipped with permanently attached swinging mounting brackets that are easily rotated out of the way after marking wall for drilling mounting holes. The rotating feature of the mounting brackets will accommodate slight mounting hole misalignment.

• Rotate mounting brackets to extended position before lifting device onto mounting channel for ease of installation.

• Rotating mounting brackets are provided at top and bottom of each unit to secure device to the wall.

EZM3EXT

EZM3CORNER

EZM3ELBOW

21.79[553]

7.09[180]

8.02[204]

14.88[378]

15.41[391]

8.50[216]

Common Corner Application to Meet Utility Clearance Requirements

Common Wall Application to Meet Utility Clearance

Requirementsin.

[mm]Dimensions:

Page 12: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersBussed Extension Sections (NEMA Type 3R)

12© 2008 Schneider Electric All Rights Reserved 07/2008

Determine Mounting Channel Height for Metering Equipment Lineup

• Contact your local utility to determine the following branch unit meter socket mounting height restrictions:

— Maximum dimension, centerline of top meter socket to floor or finished grade level

— Minimum dimension, centerline of bottom meter socket to floor or finished grade level

— Total branch unit meter socket height window (maximum dimension less minimum dimension).

• Contact your local utility to determine minimum dimension from bottom of main device to floor or finished grade level.

• Refer to drawings of main devices and branch units starting on page 40 and determine proper height to install mounting channels. Ensure branch unit meter sockets are positioned within total branch unit meter socket height window, and main device bottom is positioned far enough above floor or finished grade level to comply with local requirements.

• Once the mounting channel height is determined, chalk a level line on wall at proper height.

• Align top edge of mounting channels for each unit to wall in the order that they will be installed.

• Some EZM branch sections (five-position and six-position branch units) may not fit within utility’s meter height window for outdoor applications, although could be acceptable for use in indoor installations.

ChalkLine

56.51[14.35]

Chalk line on wall at proper height and secure mounting channel to wall.Mounting channel is secured to wall and device is hung on channel by bracket attached to rear of unit.

Mounting Channel

Rotating Mounting Brackets

in.[mm]Dimensions:

Top of Mounting Channel

in.[mm]Dimensions:

Maximum Meter Socket

Height Requirement

Total Meter Socket Window Height

Minimum Meter Socket Height Requirement

Mounting Channel

Main Circuit Breaker Device (Typical)

125 A and 225 A Residential Branch Units (Typical)

225 A Commercial Branch Units (Typical)

Minimum Height Requirement to Bottom of Main

14.00[356]

Typical Maximum Meter Socket

Height RequirementTotal Meter

Socket Window Height

Minimum Meter Socket Height Requirement

Floor or Finished Grade Level

Mounting Channel Height Requirements Detail

9.00[229]

Typical

C C

NOTE: See pages 14–16 for dimension “C” for each catalog number.

See note below.

Page 13: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersMain Devices

1307/2008 © 2008 Schneider Electric All Rights Reserved

Width

Height

Mounting Channel

T

B 56.51[1435]

Mounting Channel

in.[mm]Dimensions:

Main Device (Typical)

NOTE: Mounting channel height of 56.51 in. (1435 mm) is for reference only. Consult local utility for minimum and maximum meter socket height requirements to properly position mounting channel above grade level.

Main DevicesCatalog Number

Height Width Depth B T M 1

1 If channel height is 56.51 in. (1435 mm) then M =

in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm]

EZM11000CBEZM11000CBUEZM11200CBEZM11200CBUEZM11200FS

53.9770.0561.1970.0561.19

13711779155417791554

18.6634.1930.1934.1930.19

474868767868767

11.5018.3318.3318.3318.33

292466466466466

34.3046.9938.1346.9938.13

87111949691194969

19.6723.0623.0623.0623.06

500586586586586

22.219.52

18.389.52

18.38

564242467242467

EZM11200FSUEZM11600CBUEZM11200TBUEZM11600CB

70.0571.1944.7161.19

1779180811361554

34.1930.1933.1630.19

868767842767

18.3318.3311.1218.33

466466282466

46.9948.1231.1738.13

11931222792969

23.0723.0713.5423.06

586586344586

9.538.39

25.3418.38

242213644467

EZM11600TBEZM12000CBEZM12000CBUEZM12000TBEZM1225TBEZM1400CB

51.5868.9168.9171.1321.8153.97

1310175017501807554

1371

22.3330.1930.1930.1911.5018.66

567767767767292474

13.0018.3318.3321.465.81

11.50

330466466545148292

27.9244.2544.2537.6213.002

34.30

2 Device supplied without mounting channel, secure to wall by use of rotating mounting feet.

70911241124956330871

23.6624.6624.6633.518.81

19.67

601626626851224500

28.5912.2612.2618.8943.5122.21

7253113114801105564

EZM1400CBUEZM1400FSEZM1400FSUEZM1400TBEZM1400TBU

69.0353.9769.0330.4635.71

175313711753774907

20.4618.6620.4617.0017.16

520474520432436

11.5011.5011.506.538.00

292292292166203

49.3734.3049.3716.2927.17

12548711254414690

19.6619.6719.6614.178.54

499500499360217

7.1422.217.14

40.2229.34

1815641811022745

EZM1600CBEZM1600CBUEZM1600FSEZM1600FSUEZM1600TB

53.9769.0353.9769.0328.43

1371175313711753722

18.6620.4618.6620.4617.00

474520474520432

11.5011.5011.5011.506.53

292292292292166

34.3049.3734.3049.3716.29

87112548711254414

19.6719.6619.6719.6612.14

500499500499308

22.217.14

22.217.14

40.22

5641815641811022

EZM1800CBEZM1800CBUEZM1800FSEZM1800FSUEZM1800TB

53.9769.0353.9769.0353.97

13711753137117531371

18.6620.4618.6620.4618.66

474520474520474

11.5011.5011.5011.5011.50

292292292292292

34.3049.3734.3049.3734.30

87112548711254871

19.6719.6619.6719.6619.67

500499500499500

22.217.14

22.217.14

22.21

564181564181564

EZM1800TBCUEZM1800TBUEZM1EXTEZM1EXT6

51.7639.9619.3419.34

13151015491491

23.9325.0611.666.00

608637296152

6.4111.126.376.37

163282162162

28.0131.1711.852

11.852

711792301301

23.758.79——

603223——

28.5025.34

——

724644——

EZM1CORNER(indoor only) 3

19.50 495 14.40 366 8.02 204 11.852 301 — — — —

EZM1ELBOW(indoor only) 4

19.50 495 14.52 369 8.01 204 11.852 301 — — — —

EZM31000CBEZM31000CBUEZM31200CBEZM31200CBU

53.9770.0561.1970.05

1371177915541779

18.6634.1930.1934.19

474868767868

11.5018.3318.3318.33

292466466466

34.3046.9938.1346.99

87111949691194

19.6723.0623.0623.06

500586586586

22.219.52

18.389.52

564242467242

EZM31200TBUEZM31600CBEZM31600CBUEZM31600TBEZM32000CB

44.7161.1968.6955.1268.91

11361554174514001750

33.1630.1927.6922.4030.19

842767707569767

11.1218.3318.4512.9418.33

282466471329466

31.1738.1349.1229.6744.25

79296912557541124

13.5423.0619.5725.4524.66

344586525646626

25.3418.387.39

26.8412.26

644467189682311

EZM32000CBUEZM32000TBEZM3225TBEZM3400CBEZM3400CBUEZM3400FS

68.9171.1321.8153.9769.0353.97

17501807554

137117531371

30.1930.1911.5018.6620.4618.66

767767292474520474

18.3321.465.81

11.5011.5011.50

466545148292292292

44.2537.6213.002

34.3049.3734.30

11249563308711254871

24.6633.518.81

19.6719.6619.67

626851224500499500

12.2618.8943.5122.217.14

22.21

3114801105564181564

EZM3400FSUEZM3400TBEZM3400TBUEZM3600CBEZM3600CBU

69.0330.4635.7153.9769.03

1753774907

13711753

20.4617.1517.1618.6626.19

520436436474665

11.507.098.00

11.5011.65

292180203292296

49.3716.2927.1734.3049.37

12544146908711254

19.6614.178.54

19.6719.66

499360217500499

7.1440.2229.3422.217.14

1811022745564181

EZM3600FSEZM3600FSUEZM3600TBEZM3800CBEZM3800CBU

53.9769.0330.4653.9769.03

13711753774

13711753

18.6626.1917.1518.6626.19

474665436474665

11.5011.657.09

11.5011.65

292296180292296

34.3049.3716.2934.3049.37

87112544148711254

19.6719.6614.1719.6719.66

500499360500499

22.217.14

40.2222.217.14

5641811022564181

EZM3800FSEZM3800FSUEZM3800TBEZM3800TBCUEZM3800TBU

53.9769.0353.9751.7639.96

13711753137113151015

18.6626.1918.6623.9325.06

474665474608637

11.5011.6511.506.41

11.12

292296292163282

34.3049.3734.3028.0131.17

8711254871711792

19.6719.6619.6723.758.79

500499500603223

22.217.14

22.2128.5025.34

564181564724644

EZM3EXTEZM3EXT6

19.3419.34

491491

11.666.00

296152

6.376.37

162162

11.852

11.852301301

— — — —

EZM3CORNER(indoor only)3

3 Each leg of this corner section measures 14.72 in. (373.89 mm) from wall to start of next enclosure.

19.50 495 14.40 366 8.02 204 11.852 301 — — — —

EZM3ELBOW(indoor only)4

4 Each leg of elbow section measures 6.17 in. (156.72 mm) corner of wall to start of next enclosure.

19.50 495 14.52 369 8.01 204 11.852 301 — — — —

Page 14: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersMain Devices

14© 2008 Schneider Electric All Rights Reserved 07/2008

Single-Phase Branch Devices

Catalog Number (available suffix)

Height Width Depth AMtg.

Channel (B)

C T Top Meter (U)

Bottom Meter

(L)(R)

if “S Min.” for Bottom Meter = 30 then...

Top Meter is...

Mounting Channel Height

in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm]

EZM112225 (X, CUX)EZM113125 (X, CUX)EZM113225 (X, CUX)EZM114125 (X, CUX)EZM114225 (X, CUX)

43.4142.3743.4148.1252.00

11031076110312221321

17.3812.2517.3812.2517.38

441311441311441

8.097.098.097.098.09

205180205180205

9.009.009.009.009.00

229229229229229

32.3431.3032.3431.3032.34

821795821795821

20.1120.1120.1120.1120.11

511511511511511

11.0711.0711.0716.8219.66

281281281427499

22.1813.1813.189.9312.77

563335335252324

12.2311.1912.2311.1912.23

311284311284311

9.0018.0018.0027.0027.00

229457457686686

39.0048.0048.0057.0057.00

9911219121914481448

50.1150.1150.1150.1150.11

12731273127312731273

EZM115125 (X, CUX)EZM115225 (CU)EZM116125 (X, CUX)EZMH112225 (X, CUX)EZMH113125 (X, CUX)

57.1261.0066.1243.4142.37

14511549167911031076

12.2517.3812.2517.3812.25

311441311441311

7.098.097.098.097.09

180205180205180

9.009.009.009.009.00

229229229229229

31.3032.3540.3032.3431.30

7958211024821795

20.1120.1229.1120.1120.11

511511739511511

25.8228.6525.8211.0711.07

656728656281281

9.9312.779.9322.1813.18

252324252563335

11.1912.2311.1912.2311.19

284311284311284

36.0036.0045.009.0018.00

9149141143229457

66.0066.0075.0039.0048.00

1676167619059911219

50.1150.1259.1150.1150.11

12731273150112731273

EZMH113225 (X, CUX)EZMH114125 (X, CUX)EZMH114225 (X, CUX)EZMH115125 (X, CUX)EZMH115225 (CU)

43.4148.1252.0057.1261.00

11031222132114511549

17.3812.2517.3812.2517.38

441311441311441

8.097.098.097.098.09

205180205180205

9.009.009.009.009.00

229229229229229

32.3431.3032.3431.3032.35

821795821795822

20.1120.1120.1120.1120.12

511511511511511

11.0716.8219.6625.8228.65

281427499656728

13.189.9312.779.9312.77

335252324252324

12.2311.1912.2311.1912.23

311284311284311

18.0027.0027.0036.0036.00

457686686914914

48.0057.0057.0066.0066.00

12191448144816761676

50.1150.1150.1150.1150.12

12731273127312731273

EZMH116125 (X, CUX)EZMK111400EZMK112400EZML111225 (CU)EZML11225D

66.1245.5572.9939.0639.06

167911571854992992

12.2527.5627.5619.4419.44

311700700494494

7.099.749.749.449.44

180247247240240

9.00—

29.69——

229—

754——

40.3037.8137.8125.5125.51

1024960960648648

29.1116.7716.7712.1212.12

739426426308308

25.827.7435.1813.5513.55

656197894344344

9.9324.5122.2625.6725.67

252622565652652

11.1921.0421.0413.3913.39

284534534340340

45.00—

29.69——

1143—

754——

75.0030.0059.6930.0030.00

19057621516762762

59.1146.7746.7742.1242.12

15011188118810701070

EZML111400EZML112225 (CU)EZML11225DEZML112400EZML113225 (CU)

44.5539.0639.0669.6153.06

113299299217681348

23.2119.4419.4423.2119.44

590494494590494

9.449.449.449.449.44

240240240240240

—14.0014.0027.4414.00

—356356697356

37.8125.5125.5137.8139.50

9606486489601003

16.2812.1212.1216.2826.16

414308308414664

6.7413.5513.5531.8013.56

171344344808344

24.0211.6711.6720.6411.72

610296296524298

21.5313.3913.3921.5313.34

547340340547339

—14.0014.0027.4428.00

—356356697711

30.0044.0044.0057.4458.00

7621118111814591473

46.2842.1242.1246.2856.17

11761070107011751427

EZML113225DEZML114225 (CU)EZML114225DEZMR112225 (X, CUX)EZMR113125 (X, CUX)

53.0667.0667.0643.4142.37

13481703170311031076

19.4419.4419.4417.3812.25

494494494441311

9.449.449.448.097.09

240240240205180

14.0014.0014.009.009.00

356356356229229

39.5039.5039.5032.3431.30

100310031003821795

26.1626.1626.1620.1120.11

664664664511511

13.5627.5627.5611.0711.07

344700700281281

11.7211.7211.7222.1813.18

298298298563335

13.3413.3413.3412.2311.19

339339339311284

28.0042.0042.009.0018.00

71110671067229457

58.0072.0072.0039.0048.00

1473182918299911219

56.1756.1756.1750.1150.11

14271427142712731273

EZMR113225 (X, CUX)EZMR114125 (X, CUX)EZMR114225 (X, CUX)EZMR115125 (X, CUX)EZMR115225 (X, CUX)

43.4148.1252.0057.1261.00

11031222132114511549

17.3812.2517.3812.2517.38

441311441311441

8.097.098.097.098.09

205180205180205

9.009.009.009.009.00

229229229229229

32.3431.3032.3431.3032.35

821795821795822

20.1120.1120.1120.1120.12

511511511511511

11.0716.8219.6625.8228.65

281427499656728

13.189.9312.779.9312.77

335252324252324

12.2311.1912.2311.1912.23

311284311284311

18.0027.0027.0036.0036.00

457686686914914

48.0057.0057.0066.0066.00

12191448144816761676

50.1150.1150.1150.1150.12

12731273127312731273

EZMR116125 (X, CUX)EZMT111225EZMT112225EZMT113225

66.1225.1260.5679.56

167963815382021

12.2522.4222.4222.42

311570570570

7.099.389.389.38

180238238238

9.00—

19.0019.00

229—

483483

40.3016.1943.6348.25

102441111081226

29.11—

14.7419.36

739—

374492

25.828.9316.9331.31

656227430795

9.934.6712.6712.67

252119322322

11.1920.4528.8928.89

284519734734

45.00—

19.0038.00

1143—

483965

75.0030.0049.0068.00

190576212451727

59.1125.7444.7449.36

150165411361254

U

T

C

R

BS

Max.

SMin.

MountingChannel

L

125 A and 225 A Residential Branch Units (Typical)

Main Device (Typical)

AT

B

225 A CommercialBranch Units (Typical)

U

A

C

L

T

B

MountingChannel

SMin.

SMax.

R

MFloor or Finished Grade Level

Determine Height for Mounting Channel

NOTE: S Max., S Min., and M dimensions are based on local utility requirements and will determine proper height for mounting channel.

Page 15: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersMain Devices

1507/2008 © 2008 Schneider Electric All Rights Reserved

Three-Phase Branch Devices

Catalog Number (available suffix)

Height Width Depth AMtg.

Channel (B)

C T Top Meter (U)

Bottom Meter

(L)(R)

if “S Min.” for Bottom Meter = 30 then...

Top Meter is...

Mounting Channel Height

in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm]

EZM312225 (X, CUX, CA, XCA, CUXCA) 43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 22.18 563 12.23 311 9.00 229 39.00 991 50.11 1273

EZM313125 (X, CUX, CA, XCA, CUXCA) 42.37 1076 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 11.07 281 13.18 335 11.19 284 18.00 457 48.00 1219 50.11 1273

EZM313125M10 42.37 1076 12.25 311 7.09 180 10.00 254 24.29 617 12.10 307 18.08 459 10.18 259 12.19 310 20.00 508 50.00 1270 42.10 1069EZM313225 (X, CUX, CA, XCA, CUXCA) 43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 13.18 335 12.23 311 18.00 457 48.00 1219 50.11 1273

EZM314125 (X, CUX, CA, XCA, CUXCA) 48.12 1222 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 16.82 427 9.93 252 11.19 284 27.00 686 57.00 1448 50.11 1273

EZM314125M10 52.12 1324 12.25 311 7.09 180 10.00 254 34.29 871 22.10 561 17.83 453 9.93 252 12.19 310 30.00 762 60.00 1524 52.10 1323EZM314225 (X, CUX, CA, XCA, CUXCA)

52.00 1321 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 19.66 499 12.77 324 12.23 311 27.00 686 57.00 1448 50.11 1273

EZM315125 (X, CUX, CA, XCA, CUXCA)

57.12 1451 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 25.82 656 9.93 252 11.19 284 36.00 914 66.00 1676 50.11 1273

EZM315125M10 62.12 1578 12.25 311 7.09 180 10.00 254 34.29 871 22.10 561 27.83 707 9.93 252 12.19 310 40.00 1016 70.00 1778 52.10 1323EZM315225 (CU, CA, CUCA)

61.00 1549 17.38 441 8.09 205 9.00 229 32.35 822 20.12 511 28.65 728 12.77 324 12.23 311 36.00 914 66.00 1676 50.12 1273

EZM316125 (X, CUX, CA, XCA, CUXCA)

66.12 1679 12.25 311 7.09 180 9.00 229 40.30 1024 29.11 739 25.82 656 9.93 252 11.19 284 45.00 1143 75.00 1905 59.11 1501

EZMH312225 (X, CUX, CA, XCA, CUXCA)

43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 22.18 563 12.23 311 9.00 229 39.00 991 50.11 1273

EZMH313125 (X, CUX, CA, XCA, CUXCA)

42.37 1076 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 11.07 281 13.18 335 11.19 284 18.00 457 48.00 1219 50.11 1273

EZMH313225 (X, CUX, CA, XCA, CUXCA)

43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 13.18 335 12.23 311 18.00 457 48.00 1219 50.11 1273

EZMH314125 (X, CUX, CA, XCA, CUXCA)

48.12 1222 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 16.82 427 9.93 252 11.19 284 27.00 686 57.00 1448 50.12 1273

EZMH314225 (X, CUX, CA, XCA, CUXCA)

52.00 1321 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 19.66 499 12.77 324 12.23 311 27.00 686 57.00 1448 50.11 1273

EZMH315125 (X, CUX, CA, XCA, CUXCA)

57.12 1451 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 25.82 656 9.93 252 11.19 284 36.00 914 66.00 1676 50.11 1273

EZMH315225 (CU, CA, CUCA)

61.00 1549 17.38 441 8.09 205 9.00 229 32.35 822 20.12 511 28.65 728 12.77 324 12.23 311 36.00 914 66.00 1676 50.12 1273

EZMH316125 (X, CUX, CA, XCA, CUXCA)

66.12 1679 12.25 311 7.09 180 9.00 229 40.30 1024 29.11 739 25.82 656 9.93 252 11.19 284 45.00 1143 75.00 1905 59.11 1501

EZMK311400 (CA) 45.55 1157 27.56 700 9.74 247 — — 30.60 777 16.77 426 7.74 197 24.51 623 21.04 534 — — 30.00 762 46.77 1188

U

T

C

R

B

SMax.

SMin.

MountingChannel

L

125 A and 225 A Residential Branch Units (Typical)

Main Device (Typical)

AT

B

225 A CommercialBranch Units (Typical)

U

A

C

L

T

B

MountingChannel

SMin.

SMax.

R

MFloor or Finished Grade Level

Determine Height for Mounting Channel

NOTE: S Max., S Min., and M dimensions are based on local utility requirements and will determine proper height for mounting channel.

Page 16: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersMain Devices

16© 2008 Schneider Electric All Rights Reserved 07/2008

EZMK312400 (CA) 72.99 1854 27.56 700 9.74 247 29.69 754 37.81 960 16.77 426 35.18 894 22.26 565 21.04 534 29.69 754 59.69 1516 46.77 1188EZMK331400 45.55 1157 27.56 700 9.74 247 — — 30.60 777 16.77 426 7.74 197 24.51 623 21.04 534 — — 30.00 762 46.77 1188EZMK332400 72.99 1854 27.56 700 9.74 247 29.69 754 37.81 960 16.77 426 35.18 894 22.26 565 21.04 534 29.69 754 59.69 1516 46.77 1188EZML311400 (CA) 45.55 1157 23.21 589 9.44 240 — — 37.81 960 16.28 414 7.74 197 24.02 610 21.53 547 — — 30.00 762 46.28 1175EZML312225 (CU, CA, CUCA)

39.06 992 19.44 494 9.44 240 14.00 356 25.50 648 12.17 309 13.56 344 11.73 298 13.33 339 14.00 356 44.00 1118 42.17 1071

EZML31225D (CA) 39.06 992 19.44 494 9.44 240 14.00 356 25.50 648 12.17 309 13.56 344 11.73 298 13.33 339 14.00 356 44.00 1118 42.17 1071EZML312400 (CA) 69.61 1768 23.21 589 9.44 240 27.44 697 37.81 960 16.28 414 31.80 808 20.64 524 21.53 547 27.44 697 57.44 1459 46.28 1176EZML313225 (CU, CA, CUCA)

53.06 1348 19.44 494 9.44 240 14.00 356 39.50 1003 26.17 665 13.56 344 11.72 298 13.34 339 28.00 711 58.00 1473 56.17 1427

EZML313225D (CA) 53.06 1348 19.44 494 9.44 240 14.00 356 39.50 1003 26.17 665 13.56 344 11.72 298 13.34 339 28.00 711 58.00 1473 56.17 1427EZML314225 (CU, CA, CUCA)

67.06 1703 19.44 494 9.44 240 14.00 356 39.50 1003 26.17 665 27.56 700 11.73 298 13.34 339 42.00 1067 72.00 1829 56.17 1427

EZML314225D (CA) 67.06 1703 19.44 494 9.44 240 14.00 356 39.50 1003 26.17 665 27.56 700 11.73 298 13.34 339 42.00 1067 72.00 1829 56.17 1427EZML331225 (CU) 39.06 992 19.44 494 9.44 240 — — 25.50 648 12.17 309 13.56 344 25.73 654 13.33 339 — — 30.00 762 42.17 1071EZML331225D 39.06 992 19.44 494 9.44 240 — — 25.50 648 12.17 309 13.56 344 25.73 654 13.33 339 — — 30.00 762 42.17 1071EZML331400 45.55 1157 23.21 590 9.44 240 — — 37.81 960 16.28 414 7.74 197 24.02 610 21.53 547 — — 30.00 762 46.28 1176EZML332225 (CU) 39.06 992 19.44 494 9.44 240 14.00 356 25.50 648 12.17 309 13.56 344 11.74 298 13.33 339 13.99 355 43.99 1117 42.17 1071EZML332225D 39.06 992 19.44 494 9.44 240 14.00 356 25.50 648 12.17 309 13.56 344 11.74 298 13.33 339 13.99 355 43.99 1117 42.17 1071EZML332400 (CU) 69.61 1768 23.21 590 9.44 240 27.44 697 37.81 960 16.28 414 31.80 808 20.64 524 21.53 547 27.44 697 57.44 1459 46.28 1176EZML333225 (CU) 53.06 1348 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 13.56 344 11.72 298 13.34 339 28.00 711 58.00 1473 56.17 1427EZML333225D 53.06 1348 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 13.56 344 11.72 298 13.34 339 28.00 711 58.00 1473 56.17 1427EZML334225 (CU) 67.06 1703 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 27.56 700 11.72 298 13.34 339 42.00 1067 72.00 1829 56.17 1427EZML334225D 67.06 1703 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 27.56 700 11.72 298 13.34 339 42.00 1067 72.00 1829 56.17 1427EZMR312225 (X, CUX, CA, XCA, CUXCA)

43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 22.18 563 12.23 311 9.00 229 39.00 991 50.11 1273

EZMR313125 (X, CUX, CA, XCA, CUXCA)

42.37 1076 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 11.07 281 13.18 335 11.19 284 18.00 457 48.00 1219 50.11 1273

EZMR313225 (X, CUX, CA, XCA, CUXCA)

43.41 1103 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 11.07 281 13.18 335 12.23 311 18.00 457 48.00 1219 50.11 1273

EZMR314125 (X, CUX, CA, XCA, CUXCA)

48.12 1222 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 16.82 427 9.93 252 11.19 284 27.00 686 57.00 1448 50.11 1273

EZMR314225 (X, CUX, CA, XCA, CUXCA)

52.00 1321 17.38 441 8.09 205 9.00 229 32.34 821 20.11 511 19.66 499 12.77 324 12.23 311 27.00 686 57.00 1448 50.11 1273

EZMR315125 (X, CUX, CA, XCA, CUXCA)

57.12 1451 12.25 311 7.09 180 9.00 229 31.30 795 20.11 511 25.82 656 9.93 252 11.19 284 36.00 914 66.00 1676 50.11 1273

EZMR315225 (CU, CA, CUXCA)

60.94 1548 17.37 441 8.09 205 9.00 229 32.35 822 20.14 512 28.59 726 12.73 323 12.21 310 36.00 914 66.00 1676 50.14 1274

EZMR316125 (X, CUX, CA, XCA, CUXCA)

66.12 1679 12.25 311 7.09 180 9.00 229 40.30 1024 29.11 739 25.82 656 9.93 252 11.19 284 45.00 1143 75.00 1905 59.11 1501

EZMR332225 (CU) 39.06 992 19.44 494 9.44 240 14.00 356 25.50 648 12.17 309 13.56 344 11.74 298 13.33 339 13.99 355 43.99 1117 42.17 1071EZMR333225 (CU) 53.06 1348 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 13.56 344 11.72 298 13.34 339 28.00 711 58.00 1473 56.16 1426EZMR334225 (CU) 67.06 1703 19.44 494 9.44 240 14.00 356 39.50 1003 26.16 664 27.56 700 11.72 298 13.34 339 42.00 1067 72.00 1829 56.16 1426EZMT311225 (CA) 25.12 638 22.42 569 9.38 238 — — 16.19 411 — — 8.93 227 4.67 119 20.45 519 — — 30.00 762 25.74 654EZMT312225 (CA) 60.56 1538 22.42 569 9.38 238 19.00 483 43.63 1108 14.74 374 16.93 430 12.67 322 28.89 734 19.00 483 49.00 1245 44.74 1136EZMT313225 (CA) 79.56 2021 22.42 569 9.38 238 19.00 483 48.25 1226 19.36 492 31.31 795 12.67 322 28.89 734 38.00 965 68.00 1727 49.36 1254EZMT331225 25.12 638 22.42 569 9.38 238 — — 16.19 411 — — 8.93 227 4.67 119 20.45 519 — — 30.00 762 25.74 654EZMT332225 60.56 1538 22.42 569 9.38 238 19.00 483 43.63 1108 14.74 374 16.93 430 12.67 322 28.89 734 19.00 483 49.00 1245 44.74 1136EZMT333225 79.56 2021 22.42 569 9.38 238 19.00 483 48.25 1226 19.36 492 31.31 795 12.67 322 28.89 734 38.00 965 68.00 1727 49.36 1254

Three-Phase Branch Devices

Catalog Number (available suffix)

Height Width Depth AMtg.

Channel (B)

C T Top Meter (U)

Bottom Meter

(L)(R)

if “S Min.” for Bottom Meter = 30 then...

Top Meter is...

Mounting Channel Height

in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm] in. [mm]

Page 17: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersClosing Plates

1707/2008 © 2008 Schneider Electric All Rights Reserved

Closing Plates

Closing Plates—Main Devices

• EZM main devices are supplied with two closing plates, one on each side of the enclosure, to cover and seal openings for horizontal cross bus.

• Right-side closing plate is one inch deep and secured to the box side using three 1/4-20 captive screws and three 1/4-inch hex nuts. Two sealing wing nuts for this side are provided in the bag assembly packed with each main device. Holes in wing nuts and lanced ears in closing plates are provided to seal the closing plate to the box sides. Install one wing nut on screw extending through closing plate at bottom of center and the other wing nut on screw extending through the closing plate at the top front to seal.

• Left-side closing plate is two inches deep and secured to box side using three 1/4-20 carriage head screws and three 1/4-inch hex nuts. Two sealing wing nuts for this side are provided in the bag assembly packed with each device. Holes in wing nuts and lanced ears in closing plates are provided to seal the closing plate to the box sides. Install one wing nut on screw extending through the closing plate at bottom center and the other wing nut on screw extending through closing plate at the top rear to seal. Where sealing is not required, install screws from outside to inside of unit and secure with hex nuts.

Closing Plates—Branch Units

EZM branch units are shipped without closing plates, but are designed to receive one from a main device. To install, remove closing plate from side of main device before connecting branch unit to main device. After last branch unit is installed in lineup, follow closing plate installation instructions for main devices.

Closing Plates—Main Devices and Branch Units

When adding on to an existing EZM metering equipment line up, repeat the above procedure by moving closing plate to end of lineup.

Closing Plates Provided with Main Device for use at Each End of Metering Line-Up

Page 18: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersHorizontal Cross Bus

18© 2008 Schneider Electric All Rights Reserved 07/2008

Horizontal Cross Bus800 A aluminum horizontal cross bus is standard for the following devices:

• 400, 600, 800, and 1000 A main circuit breaker devices

• 400, 600, and 800 A main fusible switches

• 225, 400, 600, and 800 A main lugs terminal boxes

• 125 and 225 A residential branch units

• Right end of each horizontal cross bus bar is supplied with 1/2-13 captive bolt and Visi-Tite® nut

• Left end of each horizontal cross bus bar has a slotted end

• 800 A horizontal cross bussed units will connect with 1200 A horizontal cross bussed units

• 1Ø main and branch units have 3 horizontal cross bus bars (Ø, Ø and neutral)

• 3Ø main and branch units have 4 horizontal cross bus bars (AØ, BØ, CØ, and neutral)

• 1Ø main or branch units will not interconnect with 3Ø main or branch units.

1200 A copper horizontal cross bus is standard in the following devices:

• 1000 A “CBU” suffix main circuit breaker devices

• 1200 A “CB” and “CBU” suffix main circuit breaker devices (must be center mounted when used with branch devices with main bus rated 800 A)

• 1600 A “CB” and “CBU” suffix main circuit breaker devices (must always be center mounted)

• 1200 A “TBU” suffix main lug terminal devices (must be center mounted when used with branch devices with main bus rated 800 A)

• 1600 A “TB” suffix main lug terminal devices (must always be center mounted)

• 2000 A "TB" suffix main lug terminal devices (must always be center mounted and require the use of branch devices having 1200 A horizontal cross bus)

• 125 A and 225 A “CUX” suffix residential branch devices

• 225 A commercial branch units

• 400 A commercial branch units

• Right end of each horizontal cross bus bar is supplied with 1/2-13 captive bolt and Visi-Tite nut

• Left end of each horizontal cross bus bar has a slotted end

• 1200 A horizontal cross bussed units will connect with 800 A horizontal cross bussed units

• 1Ø main and branch units have 3 horizontal cross bus bars (Ø, Ø and neutral)

• 3Ø main and branch units have 4 horizontal cross bus bars (AØ, BØ, CØ, and neutral)

• 1Ø main or branch units will not interconnect with 3Ø main or branch units.

Right End of 3Ø Horizontal Cross Bus,

Shown with Visi-Tite Nuts

Left End of 3Ø Horizontal Cross Bus, Shown with Slotted End Bus Bars

Page 19: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEquipment Grounding Procedure

1907/2008 © 2008 Schneider Electric All Rights Reserved

Equipment Grounding Procedure

1. Install mounting channels to wall at proper height (refer to “Mounting Channel” on page 11).

2. Remove closing plates from sides of EZM main device next to where EZM branch sections are to be installed.

3. Position units on mounting channel next to each other, but do not secure rotating mounting brackets to wall at this time.

4. Remove outer covers EZM main device and exterior covers from EZM branch sections (refer to page 21 for outer covers on branch devices).

5. Remove individual meter socket cover from over horizontal cross bus area of EZM branch sections (refer to “Individual Meter Socket Covers” on page 21).

6. Bond enclosures together by sliding three captive screws from the RIGHT side of unit through holes in box side (closing plate holes), and through LEFT side of adjacent enclosure. Install three 1/4-20 hex nuts with star washer provided onto 1/4-20 captive screws and torque to 50 lb-in. (5.6 N•m). Bonding for equipment ground path is complete, and enclosure gaskets are compressed to seal connection between units.

7. Replace closing plates at each end of metering equipment lineup (refer to “Closing Plates” on page 17).

At this point, the enclosures are connected together and a bonded equipment ground path is established. The next installation step involves connection of the horizontal cross bus assemblies.

Visi-Tite® Nut Horizontal Cross Bus Connectors

• The Visi-Tite nut horizontal cross bus connector is a high-strength 1/2-13 UNC double-headed torque indicating nut. Installed as an integral part of the horizontal cross bus structure in every EZM main and branch device, this unique nut makes it possible to ensure proper torque at each connection without the need for a torque wrench.

• The torque indicating Visi-Tite nut assembly also makes it possible to reduce equipment installation time over other designs requiring the use of a torque wrench.

• When making EZM metering equipment cross bus connections, there is no need for a torque wrench. Use a socket wrench with a long handle to tighten the outer Visi-Tite nut head until it twists off and releases the RED plastic warning disc.

• If the RED disc remains visible during inspection, the horizontal cross bus assembly has not yet been tightened.

• Once the outer Visi-Tite nut head is twisted off, an inner hex-head nut remains for use with a torque wrench on maintenance checks or relocation of equipment (torque 50 lb-ft./600 lb-in. [68 N•m]).

• All phase and neutral connections to the horizontal cross bus structure are now completed.

• The final step is to secure the rotating mounting brackets to the wall at top and bottom of each EZM main and branch unit enclosure.

Captive Equipment Bonding Screws are Located on Right Side of Each EZM Main and

Branch Device

Install Hex Nuts with Star Washers onto

Captive Screws

Tighten Until Outer Head Twists Off and RED Indicating Disc Falls Away

Shown with RED Indicating Disc in Place

Shown with Outer Head and RED Indicating Disc

Falling Away

Shown After Installation of Cross Bus Structure is Complete

Page 20: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

20© 2008 Schneider Electric All Rights Reserved 07/2008

Accessories

Sealing Rings for Ring-Type Meter Sockets

Standard Snap-Type Aluminum Sealing Ring, catalog number 29209-100-01, is the standard sealing ring for all ring-type EZM branch sections. Replacement sealing rings may be ordered separately.

Snap-Type Stainless Steel Sealing Ring, catalog number ARP00026, is a non-standard sealing ring. Order separately and install when required by the local utility.

Screw-Type Aluminum Sealing Ring, catalog number 29008W, is a non-standard sealing ring. Order separately and install when required by the local utility.

Circuit Breaker Doors

125, 225, and 400 A EZM branch sections are supplied with factor-installed circuit breaker doors constructed of durable impact-resistant material. The following replacement kits are available:

• BCV replacement door for vertically operated circuit breaker handles:

— 125 A ring and ringless residential branch sections

— 225 A ring and ringless residential branch sections

— 225 A ringless commercial branch sections

— Supplied with built-in latch with padlock provisions.

• BCM replacement door for vertically operated circuit breaker handles:

— 400 A ringless commercial branch sections

— 400–800 A standard and EUSERC fusible switch main devices

— 400–1000 A standard circuit breaker main devices

— 400–1200 A EUSERC circuit breaker main devices

— Supplied with built-in latch with padlock provisions.

Individual Meter Socket Closing Plates

LEXAN® Meter Socket Closing Plate for Residential Branch Units:

• Order separately (catalog number 29007)

• For use with 125 and 200 A residential branch units

• Molded of LEXAN #141-112 polycarbonate resin

• LEXAN offers high-impact and tensile strength characteristics and contains an ultra-violet inhibitor to ensure years of clear visibility

• Closing plates have four LEXAN blades as a part of the molding used to engage meter socket jaws.

Metal Meter Socket Closing Plate for Ringless-Type Branch Units:

• Order separately (catalog number RSG4)

• For use with ringless-type branch units

• Metal closing plate attaches to individual meter socket cover from the backside with four hold-down screws

• Closing plate cannot be removed from individual meter socket cover with meter socket cover installed on branch unit.

Snap-Type Sealing Ring

Screw-Type Sealing Ring

BCV Circuit Breaker Door Shown with Door Closed

BCM Circuit Breaker Cover Shown with Door Open

LEXAN Closing Plate

Ringless-Type Metal Closing Plate

Page 21: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

2107/2008 © 2008 Schneider Electric All Rights Reserved

Branch Unit Outer Covers for Tenant Circuit Breaker and Individual Meter Socket Compartments

125 and 225 A Ring-Type Residential Branch Unit Outer Covers for Tenant Circuit Breaker Compartments and Individual Meter Socket Covers:

• Outer tenant circuit breaker covers can be removed without disturbing sealed utility meters mounted to the individual meter socket cover.

• All unmetered conductor compartments remain sealed and isolated when outer tenant circuit breaker covers are removed.

• Outer tenant circuit breaker covers are supplied with individual tenant circuit breaker doors that may be locked with a padlock.

• An individual meter socket cover is supplied for each meter socket position.

• Each ring-type meter socket cover has a rim formed into the cover to support the base of the utility meter.

• Aluminum snap-type sealing rings are standard and are used to attach the base of the utility meter to the rim. A slot is provided in the tab of the sealing ring for the local utility to install their seal to lock the meter into place.

125, 225, and 400 A Ringless-Type Branch Unit Outer Covers for Tenant Circuit Breaker Compartments and Individual Meter Socket Covers:

• Outer tenant circuit breaker covers can be removed without disturbing sealed utility meters secured under individual meter socket covers.

• All unmetered conductor compartments remain sealed and isolated when outer tenant circuit breaker covers are removed.

• Outer tenant circuit breaker covers are supplied with individual tenant circuit breaker doors that may be locked with a padlock.

• Individual ringless-type meter socket covers are supplied with stainless steel hasps that extend through cover and stainless steel latches for sealing covers to branch unit while utility meter or closing plate is mounted in meter socket.

• Ringless meter socket covers have provisions to accept utility seals including plastic padlocks, lead and wire seals, padlocks, and barrel locks, to prevent unauthorized access to meter socket compartment.

EZM113125 (Ring-Type) Outer Tenant Circuit Breaker

Cover and Individual Meter Socket Covers

EZM113200 (Ring-Type) Outer Tenant Circuit Breaker

Cover and Individual Meter Socket Covers

EZML113200 (Ringless-Type)

Outer Tenant Circuit Breaker Cover and

Individual Meter Socket Covers

EZML332200 (Ringless-Type)

Outer Tenant Circuit Breaker Cover and

Individual Meter Socket Covers

Page 22: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

22© 2008 Schneider Electric All Rights Reserved 07/2008

Branch Unit Load Neutral Terminals

125 A branch unit load neutral terminals accept one 14-2/0 AWG copper or one 12-2/0 AWG aluminum conductor per meter socket position.

225 A branch unit load neutral terminals accept one 6 AWG-300 kcmil aluminum or copper conductor per meter socket position.

400 A branch unit load neutral terminals will accept one 1/0 AWG-600 kcmil or two 1/0 AWG-250 kcmil aluminum or copper conductor(s) per meter socket position.

Branch Unit Load Equipment Grounding Terminals

Branch units are supplied with load equipment grounding terminals for feeds to downstream panelboards.

Grounding terminals on 125 and 225 A branch devices have provisions to accept one 14-2/0 AWG copper, or one 12-2/0 AWG aluminum conductor per meter socket position.

Grounding terminals on 400 A branch devices have provisions to accept one 4 AWG-300 kcmil copper or aluminum conductor per meter socket position.

Grounding terminals are factory-installed at the bottom of the wiring gutter compartment, but may be relocated to the top of the wiring gutter compartment when exiting out the top of the device.

225 A Branch Unit Load Neutral Terminals

225 A Branch Unit Load Neutral Terminals

400 A Branch Unit Load Neutral Terminals

Branch Unit Load Equipment Grounding Terminals

Page 23: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

2307/2008 © 2008 Schneider Electric All Rights Reserved

Meter Sockets

Branch Unit Tenant Circuit Breaker Types and Meter Socket Configurations

EZM branch units are supplied with meter sockets and provisions for mounting tenant circuit breakers to feed downstream type QO or HOM load centers or type NQOD panelboards. The following table includes standard and optional branch unit features along with tenant circuit breaker types and meter socket configurations.

Ring-Type Residential Meter Socket Compartment Standard Features

• 1Ø IN, 1Ø OUT branch sections include three horizontal cross bus bars and a four-jaw meter socket.

• 3Ø IN, 1Ø OUT branch sections include four horizontal cross bus bars and a five-jaw meter socket.

— 120/208 Vac, 1Ø3W (derived from a 208Y/120 Vac, 3Ø4W network). Standard 3Ø IN/1Ø OUT branch units are suitable for use on this system.

— 120/240 Vac, delta, 1Ø3W (fed from transformer’s AØ and CØ only). Connection to high-leg BØ not permitted for use on this system. Standard 3Ø IN/1Ø OUT branch units are not suitable for use on this system. Special branch units are available for this system by adding suffix “CA” to catalog number; for example: EZM313125CA.

• Meter socket jaws are front removable and spring reinforced.

• Meter blade guides are supplied as standard on both line and load side meter socket jaws.

• 200 A continuous duty rated meter socket jaws supplied without bypass.

• Aluminum snap-type sealing ring supplied with each meter socket as standard.

EZM115125 EZM113225

125 A and 225 A Ring-Type Meter Socket, Four-Jaw

without Bypass

125 A and 225 A Ring-Type Individual Meter Socket Cover Shown without Sealing Ring

125 A and 225 A Ring-Type EZM Residential Branch Units (1Ø OUT)

Meter Socket Ring-Type (Quantity)

Four-Jaw Meter Socket 1Ø IN

Five-Jaw Meter Socket 3Ø IN

Circuit Breaker Type

(Two-Pole Only)Catalog Number Catalog Number

125 A Ring-Type Residential without Bypass

Three-PositionEZM113125—EZM113125CUX

EZM313125EZM313125M10EZM313125CUX

QO, QO-VH, QOH

Four-PositionEZM114125—EZM114125CUX

EZM314125EZM314125M10EZM314125CUX

QO, QO-VH, QOH

Five-PositionEZM115125—EZM115125CUX

EZM315125EZM315125M10EZM315125CUX

QO, QO-VH, QOH

Six-Position EZM116125EZM116125CUX

EZM316125EZM316125CUX QO, QO-VH, QOH

225 A Ring-Type Residential without Bypass

Two-Position EZM112225EZM112225CUX

EZM312225EZM312225CUX QB, QD, QG, QJ

Three-Position EZM113225EZM113225CUX

EZM313225EZM313225CUX QB, QD, QG, QJ

Four-Position EZM114225EZM114225CUX

EZM314225EZM314225CUX QB, QD, QG, QJ

Five-Position EZM115225EZM115225CU

EZM315225EZM315225CU QB, QD, QG, QJ

Page 24: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

24© 2008 Schneider Electric All Rights Reserved 07/2008

125 A Tenant Circuit Breaker Compartment

• 125 A maximum branch units will accept 40–125 A two-pole plug-on type QO, QO-VH, or QOH circuit breakers (order circuit breakers separately).

• Refer to pages 3 and 4 for meter center available short circuit current ratings with the above tenant circuit breakers installed.

225 A Tenant Circuit Breaker Compartment

• 225 A maximum branch units listed in this section will accept 100–225 A two-pole bolt-on type QB, QD, QG, or QJ circuit breakers.

• With the use of plug-on adapter catalog number EZM125QOA, these units will accept 40–125 A two-pole plug-on type QO, and 40–60 A two-pole plug-on type QO-VH and QOH circuit breakers. (Order circuit breakers and adapters separately.)

• Refer to pages 3 and 4 for meter center available short circuit current ratings with the above tenant circuit breakers installed.

Optional Ring-Type Residential Meter Socket Features

• Five-jaw kit catalog number 5J (one kit required per meter socket) is available for field installation and can be mounted on the meter socket base assembly at three, six, or nine o’clock positions. Used to convert a four-jaw 125 A or 225 A ring-type branch unit meter socket to a five-jaw meter socket.

• Five-jaw meter sockets are required for a 120/208 Vac, 1Ø3W service derived from a 208Y/120 Vac, 3Ø4W system.

• Manual slider type bypass kit catalog number MM200MB is available for field installation. It includes manual slider-type bypass and replacement individual meter socket cover (cover is notched to allow handle of slider bypass to pass through rim with meter installed). Slider-type bypass is intended for temporary use only (not continuous duty rated). Available short circuit current rating of metering equipment is limited to 10,000 RMS symmetrical amperes with slider-type bypass kits installed.

• Plug-on adapter kit catalog number EZM125QOA available for use in 225 A branch units that use bolt-on type QB, QD, QG, or QJ two-pole tenant circuit breakers. Kit will accept 40–125 A two-pole plug-on type QO, and 40–60 A two-pole plug-on type QO-VH and QOH circuit breakers. (Order circuit breakers and adapters separately.)

125 A Tenant Circuit Breaker Base (Two-Pole)

QO2100 Tenant Circuit Breaker Installed

225 A Q2M Tenant Circuit Breaker Base

(Two-Pole)

Five-Jaw Kit (5J) Installed at the 9 O’Clock Position

Manual Slider-Type Bypass Shown in

Closed Position with Handle Extending

through Notch in Rim of Meter Socket Cover

Manual Slider-Type Bypass Shown in Open

Position with Handle Secured by Notch Meter

Socket Sealing Ring

EZM125QOA Two-Pole Plug-On Adapter Kit for use in QB, QD, QG, or QJ Bolt-On Tenant Circuit Breaker Compartments

Page 25: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersAccessories

2507/2008 © 2008 Schneider Electric All Rights Reserved

Ringless Residential Meter Socket Compartment Standard Features

• 1Ø IN, 1Ø OUT branch sections (includes three horizontal cross bus bars). Five-jaw meter sockets supplied as standard.

• 3Ø IN, 1Ø OUT branch sections (includes four horizontal cross bus bars).Five-jaw meter sockets supplied as standard.

— 120/208 Vac, 1Ø3W (derived from a 208Y/120 Vac, 3Ø4W service).Standard 3Ø IN/1Ø OUT branch units are suitable for use on this system.

— 120/240 Vac, 1Ø3W (fed from transformer’s AØ and CØ only). Connection to high-leg BØ not permitted for use on this system. Standard 3Ø IN/1Ø OUT branch units are available for this system by adding suffix “CA” to catalog number (Examples: EZMR313125CA, EZMH314125CA, EZMR313225CA and EZMH312225CA).

EZMH114125

125 A and 225 A Ringless Meter Socket

with Horn Bypass

125 A and 225 A Ringless-Type Individual Meter Socket Cover

Shown with Stainless Steel Hasp and Latch for use with

Utility Seals

125 A and 225 A Ringless-Type EZMR and EZMH Residential Branch Units (1Ø OUT)

Meter Socket Ringless-Type

(Qty.)

Five-Jaw Meter Socket1Ø IN

Five-Jaw Meter Socket 3Ø IN

Circuit Breaker Type

(Two-Pole Only)Catalog Number Catalog Number

125 A Ringless without Bypass

Three-Position EZMR113125EZMR113125CUX

EZMR313125EZMR313125CUX QO, QO-VH or QOH

Four-Position EZMR114125EZMR114125CUX

EZMR314125EZMR314125CUX QO, QO-VH or QOH

Five-Position EZMR115125EZMR115125CUX

EZMR315125EZMR315125CUX QO, QO-VH or QOH

Six-Position EZMR116125EZMR116125CUX

EZMR316125EZMR316125CUX QO, QO-VH or QOH

225 A Ringless without Bypass

Two-Position EZMR112225EZMR112225CUX

EZMR312225EZMR312225CUX QB, QD, QG or QJ

Three-Position EZMR113225EZMR113225CUX

EZMR313225EZMR313225CUX QB, QD, QG or QJ

Four-Position EZMR114225EZMR114225CUX

EZMR314225EZMR314225CUX QB, QD, QG or QJ

Five-Position EZMR115225EZMR115225CU

EZMR315225EZMR315225CU QB, QD, QG or QJ

125 A Ringless with Horn Bypass

Three-Position EZMH113125EZMH113125CUX

EZMH313125EZMH313125CUX QO, QO-VH or QOH

Four-Position EZMH114125EZMH114125CUX

EZMH314125EZMH314125CUX QO, QO-VH or QOH

Five-Position EZMH115125EZMH115125CUX

EZMH315125EZMH315125CUX QO, QO-VH or QOH

Six-Position EZMH116125EZMH116125CUX

EZMH316125EZMH316125CUX QO, QO-VH or QOH

225 A Ringless with Horn Bypass

Two-Position EZMH112225EZMH112225CUX

EZMH312225EZMH312225CUX QB, QD, QG or QJ

Three-Position EZMH113225EZMH113225CUX

EZMH313225EZMH313225CUX QB, QD, QG or QJ

Four-Position EZMH114225EZMH114225CUX

EZMH314225EZMH314225CUX QB, QD, QG or QJ

Five-Position EZMH115225EZMH115225CU

EZMH315225EZMH315225CU QB, QD, QG or QJ

Page 26: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

26© 2008 Schneider Electric All Rights Reserved 07/2008

General Information:• Meter socket jaws are removable from the front and spring-reinforced.

• Meter blade guides supplied as standard on both line and load side meter socket jaws.

• 200 A continuous duty rated meter socket jaws supplied with fifth jaw.

• Individual ringless-type meter socket covers are provided with stainless steel hasps that extend through cover, and stainless steel latches for sealing covers to branch unit. The utility meter or closing plate is mounted in meter socket.

• Ringless meter socket covers have provisions to accept utility seals including plastic padlocks, lead and wire seals, and barrel locks to prevent unauthorized access to meter socket compartment.

125 A Tenant Circuit Breaker Compartment

• 125 A maximum residential branch units will accept 40–125 A, two-pole, plug-on type QO, QO-VH, or QOH circuit breakers (order circuit breakers separately).

• Refer to pages 3 and 4 for meter center available short circuit current ratings with the above tenant.

225 A Tenant Circuit Breaker Compartment

• 225 A maximum branch units listed in this section will accept 100–225 A, two-pole, bolt-on type QB, QD, QG, or QJ circuit breakers.

• Or with the use of plug-on adapter catalog number EZM125QOA, these units will accept 40–125 A, two-pole plug-on type QO, and 40–60 A two-pole plug-on type QO-VH and QOH circuit breakers. (Order circuit breakers and adapters separately.)

• Refer to pages 3 and 4 for meter center available short circuit current ratings with the above tenant circuit breakers installed.

Optional Ringless Residential Meter Socket Features

• Barrel lock head protector kit, catalog number MMBLC (one kit covers six meter sockets) is available for field-installation.

— Knockout in individual meter socket cover is provided for barrel lock head protector kit.

— Secure head protector kit to cover with lock nut supplied.

— Barrel lock not supplied.

• Horn bypass kit catalog number MMHB (one kit required per meter socket) is available for field-installation.

— To install horn bypass kit remove one of four 1/4-inch hex nuts from meter socket jaw assemblies and position horn bypass bus bar connector on top of meter jaw. Secure with hex nut and torque to 75 lb-in. (8.5 N•m). Repeat this process for remaining three jaw positions.

— Horn bypass bus bars are of different shapes, and must be installed as shown (refer to instructions provided with each kit).

— Horn bypass factory-installed on EZMH device.

125 A QO Tenant Circuit Breaker Base

(Two-Pole)

QO2100 Tenant Circuit Breaker

Installed

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Head Protector

(Catalog Number MMBLC)

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Installed through Cover and

Lock Bracket (Reverse View)

Residential Horn Type Bypass Kit Available for Use on EZMR Ringless Branch Units, and Standard on EZMH Ringless Branch Units

225 A Q-Frame Tenant Circuit Breaker Base

(Three-Pole)

Page 27: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

2707/2008 © 2008 Schneider Electric All Rights Reserved

NOTE: EZMT devices are supplied with Test Block Bypass, which meets EUSERC requirements.

Ringless Commercial Meter Socket Compartment Standard Features

• 1Ø IN, 1Ø OUT branch units (include three horizontal cross bus bars). Five-jaw meter sockets supplied as standard. Not available in 400 A branch unit.

• 3Ø IN, 1Ø OUT branch units (include four horizontal cross bus bars). Five-jaw meter sockets supplied as standard.

— 120/208 Vac, 1Ø3W (derived from a 208Y/120 Vac, 3Ø4W service). Standard 3Ø IN/1Ø OUT branch units are suitable for use on this system.

— 120/240 Vac, 1Ø3W (fed from transformer’s AØ and CØ only). Connection to high-leg BØ not permitted for use on this system. Standard 3Ø IN/1Ø OUT branch units are not suitable for use on this Delta system. Special branch units are available for this system by adding suffix: “CA” to catalog number (Examples: EZML313125CA and EZML312400CA).

• 320 A continuous duty rated meter sockets supplied with lever bypass.

• Lever bypass meter sockets are supplied with jaw release.

EZML113225

EZMT311225

225 A Ring-Type EZMT Commercial Branch Units (1Ø OUT)

Meter Socket Ringless-Type

(Qty)

Five-Jaw Meter Socket 1Ø IN

Five-Jaw Meter Socket 3Ø IN

Circuit Breaker Type

(Two-Pole Only)Catalog Number Catalog Number

225 A Ring-Type with Test Block Bypass

One-Position EZMT111225 EZMT311225 QB, QD, QG, or QJ

Two-Position EZMT112225 EZMT312225 QB, QD, QG, or QJ

Three-Position EZMT113225 EZMT313225 QB, QD, QG, or QJ

225 A and 400 A Ringless-Type EZML and EZMK Commercial Branch Units (1Ø OUT)

Meter Socket Ringless-Type

(Qty)

Five-Jaw Meter Socket 1Ø IN

Five-Jaw Meter Socket 3Ø IN

Circuit Breaker Type

(Two-Pole Only)Catalog Number Catalog Number

225 A Ringless with Lever Type Bypass and Jaw Release

One-PositionEZML111225EZML111225CUEZML111225D

— QB, QD, QG, or QJ

Two-PositionEZML112225EZML112225CUEZML112225D

EZML312225EZML312225CUEZML312225D

QB, QD, QG, or QJ

Three-PositionEZML113225EZML113225CUEZML113225D

EZML313225EZML313225CUEZML313225D

QB, QD, QG, or QJ

Four-PositionEZML114225EZML114225CUEZML114225D

EZML314225EZML314225CUEZML314225D

QB, QD, QG, or QJ

400 A Ringless with Lever Type Bypass and Jaw Release

One-Position EZML111400 EZML311400 DJM36400E201

1 Factory-installed.

Two-Position EZML112400 EZML312400 DJM36400E201

400 A Ringless Type K Bolt-On with Manual Bypass

One-Position EZMK1114002

2 Contains one four-jaw meter socket.

EZMK311400 DJM36400E201

Two-Position EZMK1124002 EZMK312400 DJM36400E201

225 A Ringless-Type Meter Socket, Seven-Jaw with

Lever Type Bypass Shown with Lexan Shield over Line

and Load Meter Jaws

400 A Ringless-Type Meter Socket, Five-Jaw with Lever

Type Bypass Shown with Lexan Shield over Line and

Load Meter Jaws

Page 28: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

28© 2008 Schneider Electric All Rights Reserved 07/2008

• Lever bypass meter sockets are supplied with a Lexan shield as an integral part of the meter socket assembly and used as a guide to assist mounting of utility meter.

• Ringless type K bolt-on meter sockets have a four-jaw socket and only accept a bolt-on watt-hour meter.

• Type K bolt-on meter sockets are supplied with a manual bypass.

• Individual ringless-type meter socket covers are supplied with a stainless steel hasp that extends through cover and stainless steel latches for sealing covers to branch unit while utility meter or closing plate is mounted in meter socket.

• Ringless meter socket covers have provisions to accept utility seals including plastic padlocks, lead and wire seals, padlocks, and barrel locks to prevent unauthorized access to meter socket compartment.

225 A Tenant Circuit Breaker Compartment

225 A maximum commercial branch units accept 70–225 A, two-pole, bolt-on type QB, QD, QG, or QJ circuit breakers (order circuit breakers separately). Refer to pages 3 and 4 for meter center available short circuit current ratings.

400 A Tenant Circuit Breaker Compartment

• DJM36400E20 circuit breakers are factory-installed into 400 A maximum commercial branch units. Refer to pages 3 and 4 for meter center available short circuit current ratings.

• DJM circuit breaker has adjustable trip settings from 160–400 A for field adjustment.

Optional Ringless Commercial Meter Socket Features

Barrel lock head protector kit, catalog number MMBLC (one kit covers six meter sockets) is available for field-installation.

• DJM circuit breaker seal kit, catalog number 29375, is available for field-installation.

• Knockout in individual meter socket cover is provided for barrel lock head protector kit.

• Secure head protector kit to cover with lock nut provided.

• Barrel lock not provided.

400 A EZMK Bolt-On Meter Socket

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Head Protector

(Catalog Number MMBLC)

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Installed through Cover and

Lock Bracket (Reverse View)

Page 29: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter Centers

2907/2008 © 2008 Schneider Electric All Rights Reserved

Ring-Type Commercial Meter Socket Compartment Standard Features• 3Ø IN, 3Ø OUT branch units (include four horizontal cross bus bars). Seven-jaw

meter sockets supplied as standard.• EZMT meter sockets are supplied with Test Block Bypass.• EZMT branch devices are bondable to meet EUSERC specifications.

Ringless Commercial Meter Socket Compartment Standard Features• 3Ø IN, 3Ø OUT branch units (include four horizontal cross bus bars). Seven-jaw

meter sockets supplied as standard.• 320 A continuous duty rated meter sockets are supplied with lever-type bypass.• Lever-type bypass meter socket is supplied with jaw release.• Lexan shield supplied as an integral part of meter socket assembly and used as a

guide to assist mounting of utility meter.• Individual ringless-type meter socket covers are supplied with stainless steel hasps

that extend through cover and stainless steel latches for sealing covers to branch unit while utility meter or closing plate is mounted in meter socket.

• Ringless meter socket covers have provisions to accept utility seals including plastic padlocks, lead and wire seals, and barrel locks to prevent unauthorized access to meter socket compartment.

• 400 A continuous duty rated meter sockets are supplied with a K-base bolt-on.

• 400 A K-base bolt-on are supplied with manual bypass provision.

225 A Ringless-Type Meter Socket, Seven-Jaw without Bypass Shown with Line and Load Side

Blade Guides

225 A Ringless-Type Individual Meter Socket

Cover Shown with Stainless Steel Hasp and Latch for

Use with Utility Seals

400 A Ringless-Type Meter Socket, Five-Jaw with

Lever Type Bypass Shown with Lexan Shield over

Line and Load Meter Jaws

400 A Ringless-Type Individual Meter

Socket Cover

EZMT311225

EZML334225 EZML311400

225 A Ring-Type EZMT Commercial Branch Units (3Ø OUT)

Meter Socket Ringless-Type (Qty)

Seven-Jaw Meter Socket 3Ø IN Circuit Breaker Type (Three-Pole Only)Catalog Number

225 A Ring Type with Test Block Bypass

One-Position EZMT331225 QB, QD, QG, or QJ

Two-Position EZMT332225 QB, QD, QG, or QJ

Three-Position EZMT333225 QB, QD, QG, or QJ

225 A and 400 A Ringless-Type Commercial Branch Units (3Ø OUT)

Meter Socket Ringless-Type (Qty)

Seven-Jaw Meter Socket 3Ø IN Circuit Breaker Type (Three-Pole Only)Catalog Number

225 A Ringless without Bypass

Two-Position EZMR332225EZMR332225CU QB, QD, QG, or QJ

Three-Position EZMR333225EZMR333225CU QB, QD, QG, or QJ

Four-Position EZMR334225EZMR334225CU QB, QD, QG, or QJ

225 A Ringless with Lever Type Bypass and Jaw Release

One-PositionEZML331225

EZML331225CUEZML331225D

QB, QD, QG, or QJ

Two-PositionEZML332325

EZML332225CUEZML332225D

QB, QD, QG, or QJ

Three-PositionEZML333225

EZML333225CUEZML333225D

QB, QD, QG, or QJ

Four-PositionEZML334225

EZML334225CUEZML334225D

QB, QD, QG, or QJ

400 A Ringless with Lever Type Bypass and Jaw Release

One-Position EZML331400 DJM36400E20 1

1 Factory-installed.

Two-Position EZML332400 DJM36400E20 1

400 A Ringless Type K with Manual Bypass Provision

One-Position EZMK331400 DJM36400E20 1

Two-Position EZMK332400 DJM36400E20 1

Page 30: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

30© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers

225 A Tenant Circuit Breaker Compartment

225 A maximum commercial branch units will accept 70–225 A three-pole bolt-on type QB, QD, QG, or QJ circuit breakers. (Order circuit breakers separately.) Refer to pages 3 and 4 for meter center available short circuit current ratings.

400 A Tenant Circuit Breaker Compartment

• DJM36400E20 circuit breakers are factory-installed into 400 A maximum commercial branch units. Refer to pages 3 and 4 for meter center available short circuit current ratings.

• DJM circuit breaker has adjustable trip settings from 160–400 A.

Optional Ringless Commercial Meter Socket Features

Barrel lock head protector kit, catalog number MMBLC, (one kit covers six meter sockets), is available for field-installation.

• Knockout in individual meter socket cover is provided for barrel lock head protector kit.

• Secure head protector kit to cover with lock nut, provided.

• Barrel lock not provided.

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Head Protector

(Catalog Number MMBLC)

Ringless-Type Individual Meter Socket Cover

Shown with Barrel Lock Installed through Cover and

Lock Bracket (Reverse View)

Q-Frame Circuit Breaker Installed

DJM Circuit Breaker Installed

Page 31: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersFactory Phase Balancing

3107/2008 © 2008 Schneider Electric All Rights Reserved

Factory Phase Balancing

Branch unit meter sockets are phase balanced at the factory according to the following table:

NOTE: Refer to page 27 for branch units in the field.

EZM314125

Meter Socket (Quantity)

Catalog Number

AØ—BØ(Quantity)

AØ—CØ(Quantity)

BØ—CØ(Quantity)

125 A Branch Units (used on 120/208 Vac, 1Ø3W service derived from a 208Y/120 Vac, 3Ø4W system)

Three-Position EZM313125 1 1 1

Four-Position EZM314125 1 2 1

Five-Position EZM315125 2 1 2

Six-Position EZM316125 2 2 2

Three-Position EZMR313125 1 1 1

Four-Position EZMR314125 1 2 1

Five-Position EZMR315125 2 1 2

Six-Position EZMR316125 2 2 2

Three-Position EZMH313125 1 1 1

Four-Position EZMH314125 1 2 1

Five-Position EZMH315125 2 1 2

Six-Position EZMH316125 2 2 2

225 A Branch Units (used on 120/208 Vac, 1Ø3W service derived from a 208Y/120 Vac, 3Ø4W system)

Two-Position EZM312225 1 0 1

Three-Position EZM313225 1 1 1

Four-Position EZM314225 1 2 1

Two-Position EZMR312225 1 0 1

Three-Position EZMR313225 1 1 1

Four-Position EZMR314225 1 2 1

Two-Position EZMH312225 1 0 1

Three-Position EZMH313225 1 1 1

Four-Position EZMH314225 1 2 1

Two-Position EZML312225 1 0 1

Three-Position EZML313225 1 1 1

Four-Position EZML314225 1 2 1

400 A Branch Units (used on 120/208 Vac, 1Ø3W service derived from a 208Y/120 Vac, 3Ø4W system)

One-Position EZML311400 0 1 0

Two-Position EZML312400 1 0 1

Page 32: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

32© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Factory Phase Balancing

Phase Balancing Flexibility

The major benefit of factory phase balancing is that most jobs will not require field phase balancing. To see if meter socket phase balancing in the field is required (refer to wiring diagram for complete instructions):

A. Determine if the load in amperes on each phase of the transformer using handle rating of tenant circuit breakers installed at each number of meter sockets. Use Phase Balancing Chart to determine total number of connections each meter socket makes on each phase of transformer.

B. If phase balancing is required, determine which meter sockets should be changed to properly phase balance metering equipment lineup.

C. Once meter socket(s) is selected to be phase balanced, remove individual meter socket cover from each meter socket to be phase balanced. The vertical bus bars running top to bottom in the branch unit behind each meter socket are phased: AØ, BØ, CØ, left to right.

D. By moving only the line side meter socket “Z” shaped connectors per meter socket to be changed, phase balancing can easily be accomplished on-site:

To change an AØ and CØ meter socket to a BØ and CØ meter socket:

Starting PositionPossible Ending Position

(by moving only one “Z” connector)

AØ and BØ can be changed to AØ and CØ

AØ and CØ can be changed to AØ and BØ or BØ and CØ

BØ and CØ can be changed to AØ and CØ

Page 33: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

3307/2008 © 2008 Schneider Electric All Rights Reserved

EZM Main Device Types and Configurations

EZM main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes; for use in single-phase or three-phase applications. An EZM main device is required upstream from EZM branch units even in the case of the NEC six Disconnect rule. EZM main devices ending in “-CB”, “-FS”, or “-TB” are configured for overhead (top feed) or underground (bottom feed) service, and are supplied with lugs. EZM main devices ending in “-CBU”, “-FSU”, or “-TBU” are configured for underground (bottom feed) service only, and are equipped with lug landing pads (lugs must be ordered separately).

EZM1800CB

EZM31600CB

EZM32000CB

Circuit Breaker Main Devices (Fed from Overhead or Underground Service)

Service Type

Ampere Rating

Catalog Number

Circuit Breaker1

1 Supplied factory-installed.

Line Phase Terminal

Wire Range (AWG-kcmil,

Al/Cu)

Line Neutral Terminal

Wire Range (AWG-kcmil,

Al/Cu)

Service Grounding Terminal

Wire Range (AWG-kcmil,

Al/Cu)

1Ø IN Circuit Breaker Main Devices (Fed from Overhead or Underground Service)

1Ø3W, 120/240

Vac

400 EZM1400CB LHP264002

2 Handle extension available, order kit AHEXLI. Handle is hinged, allowing it to be tucked under door on cover.

(1) 1/0–600 or (2) 1/0–2503

3 Alternate lug kits are available for use on line side of circuit breaker (refer to most current Digest).

(1) 1/0–600 or (2) 1/0–2504

4 Alternate neutral lug available, order one MMLK500 for use of two 3/0 AWG–500 kcmil Al/Cu (includes three two-barrel lugs). Neutral will accommodate one two-barrel lug only.

(1) 6–300

600 EZM1600CB MHP266002 (3) 3/0–5003 (4) 3/0–5005

5 Alternate neutral lugs available, order one MMLK250 for use of one 1/0 AWG–600 kcmil Al/Cu or two 1/0 AWG–250 kcmil Al/Cu (includes three two-barrel lugs). Neutral will accommodate two two-barrel lugs only.

(1) 6–300

800 EZM1800CB MHP268002 (3) 3/0–5003 (4) 3/0–5005 (1) 6–300

1000 EZM11000CB MHP2610002 (3) 3/0–5003 (4) 3/0–5005 (1) 6–300

1200 EZM11200CB PAF2026 with PA21200RC

(4) 1/0–750 or (8) 1/0–250

(4) 1/0–750 or (8) 1/0–250 (1) 6–300

1600 EZM11600CB PAF2026 with PA21600RC

(6) 1/0–750 or (12) 1/0–250

(6) 1/0–750 or (12) 1/0–250 (1) 6–300

2000 EZM12000CB RJF26200 (6) 1/0–750 or (12) 1/0–250

(6) 1/0–750 or (12) 1/0–250 (1) 6–300

3Ø IN Circuit Breaker Main Devices (Fed from Overhead or Underground Service)

3Ø4W, 208Y/120

Vac or

240/120 Vac

Delta

400 EZM3400CB LHP364002 (1) 1/0–600 or (2) 1/0–2503

(1) 1/0–600 or (2) 1/0–2504 (1) 6–300

600 EZM3600CB MHP366002 (3) 3/0–5003 (4) 3/0–5005 (1) 6–300

800 EZM3800CB MHP368002 (3) 3/0–5003 (4) 3/0–5005 (1) 6–300

1000 EZM31000CB MHP3610002 (3) 3/0–5003 (4) 3/0–5005 (1) 6–300

1200 EZM31200CB PAF2036 with PA31200RC

(4) 1/0–750 or (8) 1/0–250

(4) 1/0–750 or (8) 1/0–250 (1) 6–300

1600 EZM31600CB PAF2036 with PA31600RC

(6) 1/0–750 or (12) 1/0–250

(6) 1/0–750 or (12) 1/0–250 (1) 6–300

2000 EZM32000CB RJF36200 (6) 1/0–750 or (12) 1/0–250

(6) 1/0–750 or (12) 1/0–250 (1) 6–300

Page 34: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

34© 2008 Schneider Electric All Rights Reserved 07/2008

Grounding Provisions

Service Grounding

• Each main device is equipped with a service grounding lug and provisions to bond the neutral to the enclosure when required.

• EZM main devices are suitable for use as service equipment.

EZM1800CBU

EZM1800CBU

EZM32000CBU

Circuit Breaker Main Devices (Fed from Underground Service Only)

Service Type Ampere Rating Catalog Number Circuit

Breaker 1

1 Supplied factory-installed.

Line Phase and Neutral Lug Landing

Pads provided for use with Crimp-Type Lugs (Two-Hole Mounting)

Quantity of Lugs permitted per Pad

Service Grounding Terminal

Wire Range (AWG-kcmil, Al/Cu)

1Ø IN Circuit Breaker Main Devices (Fed from Underground Service Only)

1Ø3W, 120/240 Vac

400 EZM1400CBU 2

2 Meets Electrical Utility Service Equipment Requirements Committee (EUSERC) Standards for West Coast based utilities.

LHF26400 3

3 Handle extension available, order kit AHEXLI. Handle is hinged, allowing it to be tucked under door on cover.

1 4

4 Order lugs separately.

(1) 6–300

600 EZM1600CBU 2 MHF26600 3 2 4 (1) 6–300

800 EZM1800CBU 2 MHF26800 3 2 4 (1) 6–300

1000 EZM11000CBU 2 MHF2210003 3 4 (1) 6–300

1200 EZM11200CBU 2 MHF2212003 3 4 (1) 6–300

1600 EZM11600CBU 5

5 Does not meet EUSERC Standards.

PA2026 with PA21600RC 6 4 (1) 6–300

2000 EZM12000CBU 5 RJF26200 (6) 1/0–750 or (12) 1/0–250 (1) 6–300

3Ø IN Circuit Breaker Main Devices (Fed from Underground Service Only)

3Ø4W, 208Y/120 Vac

or 240/120 Vac Delta

400 EZM3400CBU 2 LHF36400 3 1 4 (1) 6–300

600 EZM3600CBU 2 MHF36600 3 2 4 (1) 6–300

800 EZM3800CBU 2 MHF36800 3 2 4 (1) 6–300

1000 EZM31000CBU 2 MHF3210003 3 4 (1) 6–300

1200 EZM31200CBU 2 MHF3212003 3 4 (1) 6–300

1600 EZM31600CBU 5 PAF2036 with PA31600RC 6 4 (1) 6–300

2000 EZM32000CBU 5 RJF36200 (6) 1/0–750 or (12) 1/0–250 (1) 6–300

Grounding Lug and Isolated Main Neutral Bus as Installed at Factory on Main Devices

Service Grounding Lug, Bonding Strap, and Bonded Main Neutral Bus as

installed on Main Devices at Job Site as Required for use as Service Equipment

Page 35: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

3507/2008 © 2008 Schneider Electric All Rights Reserved

EZM3800FS

EZM3800FS

Fusible Switch Main Devices (Fed from Overhead or Underground Service)

Service Type

Ampere Rating

Catalog Numbers 1

1 Fuses not included. Order 300 V Class T fuses.

Molded Case Switch 2

2 Supplied factory-installed.

Line Phase Terminal

Wire Range (AWG-kcmil,

Al/Cu)

Line Neutral Terminal

Wire Range (AWG-kcmil,

Al/Cu)

Service Grounding Terminal

Wire Range (AWG-kcmil,

Al/Cu)

1Ø IN Fusible Switch Main Devices (Fed from Overhead or Underground Service)

1Ø3W, 120/240

Vac

400 EZM1400FS LHP26000M 3

3 Handle extension available, order kit AHEXLI. Handle is hinged, allowing it to be tucked under door on cover.

(1) 1/0–600 or (2) 1/0–250 4

4 Alternate lug kits are available for use on line side of molded case switch (refer to most current Digest).

(1) 1/0–600 or (2) 1/0–250 5

5 Alternate neutral lug available, order one MMLK500 for use of two 3/0 AWG-500 kcmil Al/Cu (includes three two-barrel lugs). Neutral will accommodate one two-barrel lug only.

(1) 6–300

600 EZM1600FS MHP260006M 3 (3) 3/0–500 4 (4) 3/0–500 6

6 Alternate neutral lugs available, order one MMLK250 for use on 1/0 AWG-600 kcmil Al/Cu or two 1/0 AWG-250 kcmil Al/Cu (includes three two-barrel lugs). Neutral will accommodate two two-barrel lugs only.

(1) 6–300

800 EZM1800FS MHP260008M 3 (3) 3/0–500 4 (4) 3/0–500 6 (1) 6–300

1200 EZM11200FS PHF260000M (4) 1/0–750 or (8) 1/0–250

(4) 1/0–750 or (8) 1/0–250 (1) 6–300

3Ø IN Fusible Switch Main Devices (Fed from Overhead or Underground Service)

3Ø4W, 208Y/120

Vac or 240/120

Vac Delta

400 EZM3400FS LHP36000M 3 (1) 1/0–600 or (2) 1/0–250 4

(1) 1/0–600 or (2) 1/0–250 5 (1) 6–300

600 EZM3600FS MHP360006M 3 (3) 3/0–500 4 (4) 3/0–500 6 (1) 6–300

800 EZM3800FS MHP360008M 3 (3) 3/0–500 4 (4) 3/0–500 6 (1) 6–300

Fusible Switch Main Devices (Fed from Underground Service Only)

Service Type

Ampere Rating

Catalog Numbers 1

1 Fuses not included. Order 300 V Class T fuses.

Molded Case Switch 2

2 Supplied factory-installed.

Line Phase and Neutral Lug Landing Pads

provided for use with Crimp-Type Lugs

(Two-Hole Mounting) Quantity of Lugs

Permitted per Pad

Service Grounding Terminal

Wire Range (AWG-kcmil, Al/Cu)

1Ø IN Fusible Switch Main Devices (Fed from Underground Service Only)

1Ø3W, 120/240

Vac

400 EZM1400FSU 3

3 Meets Electrical Utility Service Equipment Requirements Committee (EUSERC) Standards for West Coast based utilities.

LHF26000M 4

4 Handle extension available, order kit AHEXLI. Handle is hinged, allowing it to be tucked under door on cover.

1 5

5 Order lugs separately.

(1) 6–300

600 EZM1600FSU 3 MHF260006M 4 2 5 (1) 6–300

800 EZM1800FSU 3 MHF260008M 4 2 5 (1) 6–300

1200 EZM11200FSU 3 PHF260000M 3 5 (1) 6–300

3Ø IN Fusible Switch Main Devices (Fed from Underground Service Only)

3Ø4W, 208Y/120

Vac or 240/120

Vac Delta

400 EZM3400FSU 3 LHF36000M 4 1 5 (1) 6–300

600 EZM3600FSU 3 MHF360006M 4 2 5 (1) 6–300

800 EZM3800FSU 3 MHF360008M 4 2 5 (1) 6–300

Page 36: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

36© 2008 Schneider Electric All Rights Reserved 07/2008

EZM1800TB

EZM1800TB

EZM32000TB

Main Lugs Terminal Boxes (Fed from Overhead or Underground Service)

Service Type

Ampere Rating

Catalog Number

Line Phase Neutral Terminal Wire Range (AWG-kcmil, Al/Cu)

Service Ground Terminal Wire Range (AWG-kcmil, Al/Cu)

1Ø IN Main Lugs Terminal Boxes (Fed from Overhead or Underground Service)

1Ø3W, 120/240

Vac

225 EZM1225TB (1) 4–300 (1) 6–300

400 EZM1400TB (2) 3/0–500 1

1 Alternate lug kits available with the use of lug landing kit EZMSK2.

(1) 6–300

600 EZM1600TB (2) 1/0–750 or (4) 1/0–300 (1) 6–300

800 EZM1800TB and EZM1800TBCU (4) 3/0–500 2

2 Alternate lug kit available, order MMLK250 kits for two 1/0 AWG–600 kcmil or four 1/0 AWG–250 kcmil Al/Cu (each kit includes three two-barrel lugs) each bus bar will accept two two-barrel lugs. For 1Ø applications, order two kits. For 3Ø applications, order three kits.

(1) 6–300

1600 EZM11600TB (6) 1/0–600 or(12) 1/0–300 (1) 6–300

2000 EZM12000TB (6) 3

3 Order lugs separately. Device provided with 6 lug landing pads per phase and neutral for use with mechanical or crimp type lugs.

(1) 6–300

3Ø IN Main Lugs Terminal Boxes (Fed from Overhead or Underground Service)

3Ø4W, 208Y/120

Vac or 240/120

Vac Delta

225 EZM3225TB (1) 4–300 (1) 6–2/0

400 EZM3400TB (2) 3/0–500 1 (1) 6–300

600 EZM3600TB (2) 1/0–750 or(4) 1/0–300 (1) 6–300

800 EZM3800TB (4) 3/0–500 2 (1) 6–300

1600 EZM31600TB (6) 2–600 (1) 6–300

2000 EZM32000TB (6) 3 (1) 6–300

Main Lugs Terminal Boxes (Fed from Underground Service)

Service Type

Ampere Rating

Catalog Number1 2 3

1 For mechanical lugs (3/0 AWG–600 kcmil) order kit CMELK4, kit includes four lugs only; multiple kits may be required.

2 Meets Electrical Utility Service Equipment Requirements Committee (EUSERC) Standards for West-coast based utilities.

3 Tap box is suitable for use on Line or Load side of service equipment. Supplied with isolated neutral and provided with neutral bonding kit for use as required.

Line Phase and Neutral Lug Landing

Pads provided for use with Crimp-type Lugs (Two-hole Mounting)

Quantity of Lugs Permitted per Pad

Service Ground Terminal Wire Range (AWG-kcmil, Al/Cu)

1Ø IN Main Lugs Terminal Boxes (Fed from Underground Service Only)

1Ø3W, 120/240

Vac

400 EZM1400TBU 1 (order lugs separately) (1) 6–300

800 EZM1800TBU 2 (order lugs separately) (1) 6–300

1200 EZM11200TBU 4

4 Supplied with copper horizontal bus bars and aluminum vertical bus bars.

3 (order lugs separately) (1) 6–300

3Ø IN Main Lugs Terminal Boxes (Fed from Underground Service Only)

3Ø4W, 208Y/120

Vac or 240/120

Vac Delta

400 EZM3400TBU 1 (order lugs separately) (1) 6–300

800 EZM3800TBU 2 (order lugs separately) (1) 6–300

1200 EZM31200TBU 4 3 (order lugs separately (1) 6–300

Page 37: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

3707/2008 © 2008 Schneider Electric All Rights Reserved

EZM Main Device Standard and Alternate Lugs

Catalog Number

Standard Lugs (Factory-Installed)

Alternate Lugs by Manufacturer, Catalog Number, Wire Range AWG-kcmil, Crimping Tool, and Quantity Per Line Side Phase and Neutral (Order Lugs Separately)

ANDERSON ILSCO CMC

Line Side Phase

Terminals

Line Side Neutral

Terminals VH

CL

-600

-12B

N

VH

CL

-750

-12B

N

VA

CL

-100

0-12

BN

LID

2-60

0

LID

2-80

0

2AC

L-6

00

TA

-600

-2N

1

1 This lug is available from Schneider Electric. Order catalog number CMELK4; kit includes four lugs.

TA

-800

-2N

AU

-600

-2N

(Tw

o-B

arre

l)

A1B

2-60

0-2

2AB

2-60

0(T

wo

-Bar

rel

L1D

2-60

0

L1D

2-80

0

250-600 Cu

500-750 Cu

750-1000 Al

2-600 Al/Cu

300-800Al/Cu

250-600 Al/Cu

2-600 Al/Cu

300-800Al/Cu

(2) 2-600 Al/Cu

(2) 2-600 Al/Cu

2-600Al/Cu

(2) 2-600Al/Cu

300-800Al/Cu

VC-6 VC-7 VC-8 Mechanical IDT-12 Mechanical Mechanical Mechanical Mechanical

EZM1400CB2 3

2 Alternate lug kits are available for use on line side terminals of molded case circuit breaker or molded case switch (refer to most current Digest).3 Alternate neutral lugs available, order one kit MMLK500 for two 3/0 AWG–500 kcmil Al/Cu (kit includes three two-barrel lugs). Neutral will accommodate one two-barrel lug only.

(1) AL400LA (1) MMLK250 — — — — — — — — — — — — —

EZM1600CB2 4

4 Alternate neutral lugs available, order one kit MMLK250 for one 1/0 AWG–600 kcmil Al/Cu or two 1/0 AWG–250 kcmil (kit includes three two-barrel lugs). Neutral will accommodate two two-barrel lugs only.

(1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM1800CB2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM11000CB2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM11200CB5

5 Lugs are supplied factory-installed on the lug landing pads of this device. Alternate lugs are available.

(4) 40251-136-50 (4) 40251-136-50 4 4 — 4 — — 4 — 2 4 2 — —

EZM11600CB5 (6) 40251-136-50 (6) 40251-136-50 6 6 — 6 — — 6 — 3 6 3 — —

EZM12000CB5 (6) 40251-136-50 (6) 40251-136-50 6 6 — — — 6 — — — — — — —

EZM3400CB2 3 (1) AL400LA (1) MMLK250 — — — — — — — — — — — — —

EZM3600CB2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM3800CB2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM31000CB2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM31200CB5 (4) 40251-136-50 (4) 40251-136-50 4 4 — 4 — — 4 — 2 4 2 — —

EZM31600CB5 (6) 40251-136-50 (6) 40251-136-50 6 6 — 6 — — 6 — 3 6 3 — —

EZM32000CB5 (6) 40251-136-50 (6) 40251-136-50 6 6 — — — 6 — — — — — — —

EZM1400CBU Studs (1 lug) Studs (1 lug) 1 1 1 1 — — 1 — 1 1 1 — —

EZM1600CBU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM1800CBU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM11000CBU Studs (3 lugs) Studs (3 lugs) 3 3 — 3 — — 3 — 2 3 2 — —

EZM11200CBU Studs (3 lugs) Studs (3 lugs) 3 3 — 3 — — 3 — 2 3 2 — —

EZM11600CBU Studs (6 lugs) Studs (6 lugs) 6 6 — 6 — 6 6 6 3 6 3 6 6

EZM12000CBU Studs (6 lugs) Studs (6 lugs) 6 6 — 6 6 6

6 Wire range is limited to 750 kcmil max. in this device to comply with wire bending space requirements.

6 6 6 6 — 6 — 6 6 6

EZM3400CBU Studs (1 lug) Studs (1 lug) 1 1 1 1 — — 1 — 1 1 1 — —

EZM3600CBU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM3800CBU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM31000CBU Studs (3 lugs) Studs (3 lugs) 3 3 — 3 — — 3 — 2 3 2 — —

EZM31200CBU Studs (3 lugs) Studs (3 lugs) 3 3 — 3 — — 3 — 2 3 2 — —

EZM31600CBU Studs (6 lugs) Studs (6 lugs) 6 6 — 6 — 6 6 6 3 6 3 6 6

EZM32000CBU Studs (6 lugs) Studs (6 lugs) 6 6 6 — 6 6 6 6 6 6 6 — 6 — 6 6 6

EZM1400FS2 3 (1) AL400LA (1) MMLK250 — — — — — — — — — — — — —

EZM1600FS2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM1800FS2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM11200FS5 (4) 40251-136-50 (4) 40251-136-50 4 4 — 4 — 4 4 — 2 4 2 — —

EZM3400FS2 3 (1) AL400LA (1) MMLK250 — — — — — — — — — — — — —

EZM3600FS2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM3800FS2 4 (1) AL900MA (2) MMLK500 — — — — — — — — — — — — —

EZM1400FSU Studs (1 lug) Studs (1 lug) 1 1 1 1 — — 1 — 1 1 1 — —

EZM1600FSU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM1800FSU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM11200FSU Studs (3 lugs) Studs (3 lugs) 3 3 — 3 — 3 3 — 2 3 2 — —

EZM3400FSU Studs (1 lug) Studs (1 lug) 1 1 1 1 — — 1 — 1 1 1 — —

Page 38: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

38© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers EZM Main Device Types and Configurations

Catalog Number

Standard Lugs (Factory-Installed)

Alternate Lugs by Manufacturer, Catalog Number, Wire Range AWG-kcmil, Crimping Tool, and Quantity Per Line Side Phase and Neutral (Order Lugs Separately)

ANDERSON ILSCO CMC

Line Side Phase Terminals

Line Side Neutral

Terminals VH

CL

-600

-12B

N

VH

CL

-750

-12B

N

VA

CL

-100

0-12

BN

LID

2-60

0

LID

2-80

0

2AC

L-6

00

TA

-600

-2N

1

TA

-800

-2N

AU

-600

-2N

(Tw

o-B

arre

l)

A1B

2-60

0-2

2AB

2-60

0(T

wo

-Bar

rel

L1D

2-60

0

L1D

2-80

0

250-600 Cu

500-750 Cu

750-1000 Al

2-600 Al/Cu 300-800 250-600

Al/Cu2-600 Al/Cu 300-800 (2) 2-600

Al/Cu(2) 2-600

Al/Cu2-600Al/Cu

(2) 2-600Al/Cu

300-800Al/Cu

VC-6 VC-7 VC-8 Mechanical IDT-12 Mechanical Mechanical Mechanical Mechanical

EZM3600FSU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM3800FSU Studs (2 lugs) Studs (2 lugs) 2 2 — 2 — — 2 — 1 2 1 — —

EZM1225TB (1) 40251-052-50 (1) 40251-052-50 — — — — — — — — — — — — —

EZM1400TB2 3 4 (1) MMLK500 (1) MMLK500 1 1 — 1 1 — 1 1 — 1 — — 1

EZM1600TB2 5 (2) 40251-136-50 (2) 40251-136-50 — — — — — — — — — — — — —

EZM1800TB6 (2) MMLK500 (2) MMLK500 — — — — — — — — — — — — —

EZM11600TB (6) 40251-136-50 (6) 40251-136-50 — — — — — — — — — — — — —

EZM3225TB (1) 40251-052-50 (1) 40251-052-50 — — — — — — — — — — — — —

EZM3400TB2 3 7 (1) MMLK500 (1) MMLK500 1 1 — 1 1 — 1 1 — 1 — — 1

EZM3600TB2 5 (2) 40251-136-50 (2) 40251-136-50 — — — — — — — — — — — — —

EZM3800TB8 (2) MMLK500 (2) MMLK500 — — — — — — — — — — — — —

EZM12000TB Studs (6 lugs) Studs (6 lugs) 6 6 6 6 6 — 6 6 6 6 6 6 6

EZM31600TB (6) 40251-136-50 (6) 40251-136-50 — — — — — — — — — — — — —

EZM32000TB Studs (6 lugs) Studs (6 lugs) 6 6 6 6 6 — 6 6 6 6 6 6 6

EZM1400TBU5 Studs (1 lug) Studs (1 lug) 1 1 — 1 1 — 1 1 — 1 — — 1

EZM1800TBU5 Studs (2 lugs) Studs (2 lugs) 2 2 2 2 — 2 2 — 2 — — 2

EZM11200TBU5 Studs (3 lugs) Studs (3 lugs) 3 3 3 3 — 3 3 — 3 — — 3

EZM3400TBU/CU5 Studs (1 lug) Studs (1 lug) 1 1 1 1 — 1 1 — 1 — — 1

EZM3800TBU/CU5 Studs (2 lugs) Studs (2 lugs) 2 2 2 2 — 2 2 — 2 — — 2

EZM31200TBU/CU5 Studs (3 lugs) Studs (3 lugs) 3 3 3 3 — 3 3 — 3 — — 3

1 This lug kit is available from Schneider Electric. Order catalog number CMELK4; kit includes four lugs.2 Alternate lug requires the use of lug landing kit part number EZMSK2 (order separately).3 See pad drawing or wiring diagram for additional alternate lugs.4 Alternate lug kit available from Schneider Electric. Order one kit MMLK250 for one 1/0 AWG–600 kcmil or 2 1/0 AWG–250 kcmil Al/Cu (kit includes three two-barrel lugs) each bus bar will accept

one two-barrel lug.5 See pad drawing for additional alternate lugs.6 Alternate lug kit available from Schneider Electric. Order two MMLK250 kits for two 1/0 AWG–600 kcmil or four 1/0 AWG–250 kcmil Al/Cu (each kit includes three two-barrel lugs) each bus bar will

accept two two-barrel lugs.7 Alternate lug kit available. order two MMLK250 kits for one 1/0 AWG–250kcmil or two 1/0 AWG–250kcmil Al/Cu (each kit includes three two-barrel lugs) each bus bar will accept one two-barrel lug.8 Alternate lug kit available. Order three MMLK250 kits for two 1/0 AWG–600 kcmil or four 1/0 AWG–250 kcmil Al/Cu (each kit includes three two-barrel lugs) each bus bar will accept two two-barrel lugs.

Page 39: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersEZM Main Device Types and Configurations

3907/2008 © 2008 Schneider Electric All Rights Reserved

EZM Mains Devices

Number Segment Character Description EZM 1 1000 CB U CU

Device Name EZM EZ Meter-Pak Meter Center

Service Feed1 1Ø3W

3 3Ø4W

Mains Rating

225 A

400 A

600 A

800 A

1000 A

1200 A

1600 A

2000 A

Main Type

CB Main Circuit Breaker

FS Main Fusible Switch

TB Terminal Box

Feed DirectionBlank Overhead/Underground

U Underground Only, Meets EUSERC Standards up to 1200 A max.

Special ConstructionBlank Aluminum Horizontal Cross Bus Bar up to 1000 A max.

CU Copper Horizontal Cross Bus Bar

EZM Branch Units

Number Segment Character Description EZM R 1 1 3 125 CU

Device Name EZM EZ Meter-Pak Meter Center

Socket/Bypass Type

Blank Ring Type

R Ringless Type with 5th Jaw

H Ringless with Horn Bypass and 5th Jaw

L Lever Bypass with 5th Jaw, 7th Jaw if Three-Phase

T Ring Type Test-Block Bypass EUSERC

K K-Base Bolt-On Type

Service Feed1 1Ø3W

3 3Ø4W

Load Feed1 1Ø3W

3 3Ø4W

Number of Meter Sockets

Meter Sockets Available

1, 2, 3, 4, 5, or 6

Maximum Tenant Circuit Breaker Amperage

125 A

225 A

400 A

Special Construction

Blank Aluminum Horizontal Cross Bus Bar

CA For 240/120 Vac Delta Systems

CU Copper Horizontal Cross Bus Bar

D Removable Drip Hood with Indoor Top Endwall with Knockouts

M10 10-Inch Meter Centers

X 1200 A Copper Horizontal Cross Bus Bar

Page 40: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

40© 2008 Schneider Electric All Rights Reserved 07/2008

Dimensions and Knockouts18.66[474]14.50[368]

Omitted on1Ø Units

3.44[87]

Omitted on1Ø Units

Line Phase Lugs Line

Neutral

14.50[368]

5.09[129]

11.50[292]

Hanging Mounting Rail

53.97[1371]

24.75[629]

34.30[871]

9.13[232]11.06[281]18.48

[469]E, F, G, H, I, J

3.00[76]

2.92[74]

11.06[281]

A, B

1.12[28]

0.91[23]

5.61[142]

5.61[142]

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

1.00[25.5]

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

Left Side Closing Cap

Gasket

Captive Screw

BoxSide

Right

Sealing Wing Nut

Closing Cap

GasketRight Side Closing Cap

30.19[767]

24.00[610]

18.33[466]

Omitted on1Ø Units

Hanging Mounting Rail

38.13[969]

61.19[1554]

17.83[453]

3.44[87]

Omitted on1Ø Units

19.38[492]

24.00[610]

21.91[557]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

in.[mm]Dimensions:

30.00[762]

17.83[453]A, B

E, F, G, H, I, J3.07[78]

4.81[122]

1.16[29]

0.92[23]

6.75[171]

6.75[171]

6.75[171]

EZM1400CB, EZM3400CBEZM1600CB, EZM3600CBEZM1800CB, EZM3800CB

EZM11000CB, EZM31000CB

EZM11200CB, EZM31200CBEZM11600CB, EZM31600CB

Line Phase Lugs

Line Neutral

(1)

(1)(1)

(1)

(2)

Hex Nut (2)

(1)

(1)(1)

Top View

Page 41: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

4107/2008 © 2008 Schneider Electric All Rights Reserved

30.19[767]24.00[610]

27.35[695]

3.44[87]Typ.

24.00[610]

Grounding Lug

31.35[796]

30.00[762]

17.89[454]

68.91[1750]

18.31[465]

0.31[8]

44.50[1130]

17.89[454]

Hanging Mounting Rail

Line Neutral

Line Phase Lugs

EZM12000CB, EZM32000CB

NOTE: No knockouts provided.

in.[mm]Dimensions:

Omitted on1Ø Units

Omitted on 1Ø Units

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

1.00[25.5]

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

Left Side Closing Cap

Gasket

Captive Screw

BoxSide

Right

Gasket

Right Side Closing Cap

(1)

(1)

(1)(1)

(2)

(1)

Top View

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Box Side

NOTE: No knockouts provided.

EZM12000TB, EZM32000TB

30.19[767]24.00[610]

Omitted on 1Ø Units

21.46[545]

0.20[5]

0.34[9]Top of Mounting Channel

3.44[87]

30.39[772]

71.09[1806]

37.62[956]

20.73[527]

1.81[46]

See Detail B

Lug Landing Pad Detail

1/2-13 in. studs and keps nuts provided.

1.75[44]

2.69[68]

Typical30.67[779]

30.67[779]

Page 42: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

42© 2008 Schneider Electric All Rights Reserved 07/2008

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

18.66[474]14.50[368]

11.50[292]

17.72[450]

Hanging Mounting Rail3.44

[87]

Omitted on1Ø Units

53.97[1371]

34.30[871]

16.50[419]

11.06[281]

Line Phase Lugs

14.50[368]

18.48[469]

11.06[281]

3.01[76]

1.12[28]

2.92[74]

5.61[142]

5.61[142]

0.91[23]

A, B

18.48[469]

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Top View

Gasket

Left Side Closing CapGasket

Right Side Closing Cap

30.19[767]24.00[610]

18.33[465]

Hanging Mounting Rail

3.44[87]

38.13[968]

17.83[453]

24.00[610]

19.38[492]

61.19[1554]

21.91[556]

30.00[762]

3.07[78]

4.81[122]

17.83[453]A, B

1.16[29]

0.92[23]

6.75[171]

6.75[171]

6.75[171]

EZM1400FS, EZM3400FSEZM1600FS, EZM3600FSEZM1800FS, EZM3800FS

EZM11200FS

E, F, G, H, I, J

in.[mm]Dimensions:

E, F, G, H, I, J

Omitted on1Ø Units

5.09[129]

Line Neutral Lugs

Line Phase Lugs

Line Neutral Lugs

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 43: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

4307/2008 © 2008 Schneider Electric All Rights Reserved

Top View

Left Side Closing Cap Right Side Closing Cap

11.66[296]

5.85[149] 1.74

[44]

See detail C

3.44[87]

5.74[146] See detail A

11.50[292]

6.37[162]

5.81[148]

0.27[7]1.80

[46]

21.81[554]

1.21[31]

0.75[19] 4.45

[113]3.62[92]

11.38[289]

See detail B

A

D, E, F, G

See detail BE, F, G, H, I, J

AA, B

17.15[436]

13.00[330]

1.68[43]

30.46[774]

3.44[87]

9.03[229]

17.00[432]

See detail A

1.80[46]

7.09[180]

0.34[9]

0.32[8]

Top of Mounting Channel

16.29[414]

6.53[166]

0.34[9]

3.25[83]

2.00[51]

0.89[23] 5.75

[146]5.50[140]

17.00[432]

6.53[166]

2.86[73]2.84

[72]

EZM1400TB, EZM3400TBEZM1600TB, EZM3600TB

EZM1225TB, EZM3225TB

See detail C

Omitted on1Ø Units

Omitted on1Ø Units

0.34[9]

Detail ABottom Mounting Bracket

R 0.19[5]

1.50[38]

0.78[20]

1.08[27]

1.00[25]

0.25[6]

1.50[38]

0.40[10]

0.38[10]

R 0.13[3]

R 0.25[6]

Detail BCover Sealing Latch

Detail CTop Mounting Bracket

NOTE: For knockout dimensions, see table on opposite page.

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Gasket

Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 44: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

44© 2008 Schneider Electric All Rights Reserved 07/2008

EZM1800TBEZM3800TB

18.66[474]14.50[368]

3.44[87]

Omitted on 1Ø Units

Line Phase Lugs

Line Neutral

14.50[368]18.48[469]

3.00[76]

E, F, G, H, I, J

11.06[281]

1.12[28]

2.92[74]

5.61[142]

5.61[142]

0.91[23]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

A, B

11.50[292]

16.12[409]

Hanging Mounting Rail

53.97[1371]

34.30[871]

26.59[675]

11.06[281]

9.13[232]

24.00[610]

19.93[506]

1.68[43]

51.76[1315]

3.44[87]

20.71[526]

See detail C on page 43

See detail A on page 43

23.93[608] 1.81

[46]

7.09[180]

0.33[8]

Top of Mounting Channel

28.01[712]

0.34[9]

6.53[166]

See detail B on page 43E, F, G, H, I, J

2.97[75]

3.00[76]

5.61[143]Typ.

A, B

0.87[22]

3.12[79]

EZM1800TBCUEZM3800TBCU

in.[mm]Dimensions:

Omitted on 1Ø Units

Line Phase Lugs

Line Neutral

Top View

Left Side Closing Cap Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

GasketGasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 45: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

4507/2008 © 2008 Schneider Electric All Rights Reserved

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

22.48[571]

18.33[466]

21.06[535]

55.12[1400]

3.44[87]

22.37[568]

See detail C on page 43

See detail A on page 43

12.38[314]

1.81[46]

Omitted on 1Ø Units

Line Phase Lugs Line

Neutral

12.94[329]

0.33[8]

Top of Mounting Channel

29.67[754]

3.80[97]

2.97[75] 1.06

[27]

1.56[40] 5.06

[129]

6.61[168]

6.61[168]

3.90[99]

22.33[567]

See detail B on page 43E, F, G, H, I, J

A, B

5.53[140]

0.34[9]

in.[mm]Dimensions:

EZM11600TBEZM31600TB

Top View

Left Side Closing Cap

Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Gasket

Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 46: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

46© 2008 Schneider Electric All Rights Reserved 07/2008

20.46[520]16.30[414]

3.44[87]

Omitted on 1Ø Units

30.25[768]

Omitted on 1Ø Units

16.30[414]

11.50[292]

69.03[1753]

4.00[102]

11.06[281]

Hanging Mounting Rail

20.28[515]

3.03[77]

E, F, G, H, I, J

11.06[281]

A, B

1.12[28]

0.91[23]

5.80[147]

5.80[147]

4.34[110]

EZM1400CBUEZM3400CBU

49.37[1254]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

20.46[520]16.30[414]

3.44[87]

31.16[791]

16.30[414]

11.50[292]

69.03[1753]

4.00[102]

11.06[281]

Hanging Mounting Rail

49.36[1254]

Line Phase Pads

Line Phase Pads

Line Neutral Pad

Line Neutral Pad

20.28[515]

3.03[77]

E, F, G, H, I, J

11.06[281]

A, B

1.12[28]

0.91[23]

5.80[147]

5.80[147]

4.34[110]

EZM1600CBUEZM1800CBU

in.[mm]Dimensions:

Top View

Left Side Closing Cap Right Side Closing Cap

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Gasket

Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Box Side

Page 47: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

4707/2008 © 2008 Schneider Electric All Rights Reserved

34.19[868]24.00[610]

18.33[466]

Omitted on 1Ø Units

Hanging Mounting Rail

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

26.19[665]20.00[508]

11.65[296]

Hanging Mounting Rail3.44

[87]

31.16[791]

20.00[508]

69.03[1753]

4.00[102]

11.10[282]

26.00[660]

3.04[77]

E, F, G, H, I, J

11.10[282]

A, B

49.36[1254]Line

Phase Pads

Line Neutral Pad

0.92[23]

8.25[209]

8.25[209]

4.75[121]

1.13[29]

EZM3600CBUEZM3800CBU

3.44[87]

70.07[1780]

26.08[662]

Line Phase Pads

Line Neutral Pad

4.28[109]

46.99[1193]

24.00[610]34.00[864]

3.06[78]

17.83[453]

17.83[453]

1.16[29]

0.92[23]

7.75[197]

7.75[197]

7.75[197]

5.37[136]

E, F, G, H, I, J

A, B

in.[mm]Dimensions:

Omitted on 1Ø Units

EZM11000CBU, EZM31000CBU, EZM11200CBU, EZM31200CBU

Top View

Left Side Closing Cap Right Side Closing Cap

Captive Screw

Nut

Torque to 50 lb-in.

Gasket

Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Box Side

Gasket

Page 48: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

48© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

30.19[767]

0.86[22]

1.88[48]

17.61[447]

71.16[1807]

29.04[738]

1.75[44]

4.73[120]

6.75[171]

2.00[51]

6.40[163]

5.32[135] 33.16

[842]

1.75[44]

37.08[942]

18.34[466]

1.75[44]

0.97[25]

0.69[18]

2.00[51]

2.00[51]

0.62[16]

1.75[51]

30.19[767]

24.00[610]

3.44[87]Typ.

26.13[664]

24.00[610]

30.00[762]

17.89[454]

NOTE: No knockouts provided.

17.89[454]

68.91[1750]

31.35[796]

Grounding Lug

18.31[465]

0.31[8]

Hanging Mounting Rail

44.50[1130]

1.00[25]

EZM11600CBUEZM31600CBU

NOTE: No knockouts provided.

EZM12000CBU, EZM32000CBU

Line Lug Pads

Line Neutral

in.[mm]Dimensions:

30.00[762]

17.89[454]

Omitted on 1Ø Units

Omitted on 1Ø Units

Top View

Left Side Closing Cap Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

GasketGasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

2.00[51]0.69[18]

0.62[16]

Page 49: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

4907/2008 © 2008 Schneider Electric All Rights Reserved

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

20.46[520]16.30[414]

11.50[292]

Hanging Mounting Rail

49.37[1254]

69.03[1753]

22.00[559]

11.06[281]

20.29[515]

16.31[414]

E, F, G, H, I, J

A, B3.03[77] 11.06

[281]

1.12[28]

0.91[23]

4.34[110]

5.80[147]

5.80[147]

20.46[520]

16.30[414]

11.50[292]

3.44[87]

26.06[662]

Hanging Mounting Rail

49.36[1254]

69.03[1753]

4.75[121]

11.06[281]

16.30[414]20.28[515]

E, F, G, H, I, J

A, B3.03[77] 11.06

[281]

1.12[28]

0.91[23]

4.34[110]

5.80[147]

5.80[147]

EZM1400FSUEZM3400FSU

EZM1600FSUEZM1800FSU

Line Phase Pads

Line Neutral Pad

5.00[127]

in.[mm]Dimensions:

3.44[87]

Omitted on 1Ø Units

Omitted on 1Ø Units

Line Phase Pads

Line Neutral Pad

0.69[18]

2.00[51]

0.62[16]

1.75[51]

Top View

Left Side Closing Cap Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Gasket Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 50: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

50© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts\

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

26.19[665]20.00[508]

11.65[296]

3.44[87]

Hanging Mounting Rail

26.06[662]

69.03[1753]

Line Phase Pads

Line Neutral Pad

49.36[1254]

4.75[121]

20.00[508]

11.10[282]

26.00[660]

3.04[77]

E, F, G, H, I, J

11.10[282]

A, B

0.92[23]

8.25[209]

8.25[209]

4.75[121]

1.13[29]

EZM3600FSUEZM3800FSU

EZM11200FSU

34.26[870]

24.00[610]

18.32[465]

3.44[87]

Line Phase Pads

Line Neutral Pad

Hanging Mounting Rail

70.05[1779]

46.99[1193]6.25

[159]

17.83[453]

24.00[610]

26.08[662]

34.00[864]E, F, G,

H, I, J

A, B17.83[453]

0.92[23]

1.16[29]

3.09[78]

5.37[136]

7.75[197]

7.75[197]

7.75[197]

in.[mm]Dimensions:

0.69[18]

2.00[51]

1.75[51]

Top View

Left Side Closing Cap Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

GasketGasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut

Box Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 51: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

5107/2008 © 2008 Schneider Electric All Rights Reserved

17.16[436]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118in.

[mm]Dimensions:

13.00[330]

2.08[53]

35.72[907]

22.36[568]

1.75[44]

3.44[87]

19.88[505]

13.00[330]

2.00[51]

17.00[432]

8.00[203]

0.34[9]

Top of Mounting Channel

0.33[8]

27.17[690]

7.44[189]

E, F, G, H, I, J

A, B3.09[78]

1.18[30] 1.14

[29]5.88[149]

5.40[137]

8.00[203]

8.72[221] 25.16

[639]21.00[533]

11.68[297]

Top of Mounting Channel

3.44[87]

23.88[607]

39.97[1015]

26.44[672]

31.17[792]

0.33[8]

2.00[51]

21.00[533]

25.00[635]

11.12[283]

E, F, G, H, I, J

A, B 11.68[297]

12.05[306]

3.09[79]

1.19[30] 1.19

[30]9.92[252]

5.40[137]

EZM1400TBU, EZM3400TBU

EZM1800TBU, EZM3800TBU

Omitted on 1Ø Units

Omitted on 1Ø Units

Omitted on 1Ø Units

Omitted on 1Ø Units

1.75[44]

2.00[51]

0.69[18]

2.00[51]

0.62[16]

1.75[51]

Top View

Left Side Closing Cap Right Side Closing Cap

Box Side

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

GasketGasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Page 52: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

52© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

33.16[842]

29.00[737]

11.68[297]

3.44[87]

23.88[607]

1.75[44]

2.00[51] 4.00

[102]

44.71[1136]

26.74[679]

31.17[792]

11.12[283]

29.00[737]

33.00[838]

2.00[51]

3.09[79]

Top of MountingChannel

E, F, G, H, I, J

A, B

1.19[30]

1.19[30]

11.22[285]

5.40[137]

5.40[137]

EZM11200TBU, EZM31200TBUin.

[mm]Dimensions:

Omitted on 1Ø Units

Omitted on 1Ø Units

Top View

Left Side Closing Cap Right Side Closing Cap

Captive Screw

Gasket

Nut

Torque to 50 lb-in.

Gasket

Gasket

2.00[51]Hex

Nut (2)

Sealing Wing Nut Box

Side Left

ClosingCap

Square Neck Bolt

(1)

(1)(1)

(1)

(2)

1.00[25.5]

Captive Screw

BoxSide

Right

(1)

(1)

Sealing Wing Nut

Closing Cap

Hex Nut (2)

Box Side

Page 53: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

5307/2008 © 2008 Schneider Electric All Rights Reserved

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

12.25[311]

in.[mm]Dimensions:

2.21[56]

3.75[95]

3.44[87]Typ.

5.20[132]Typ.

Omitted on 1Ø Units

Omitted on 1Ø Units

9.00[229]Typ.

11.19[284]7.10

[180] 4.79[122]

2.48[63]4.59

[117]7.54[192]10.48[266]

1.65[42]

C, D, E

7.09[180]

42.37[1076]

1.56[40]Typ.

Hanging Mounting Rail

31.30[795]

6.59[167]

12.12[308]

8.50[216]

5.75[146] 2.44

[62]

A, B

6.59[167]

3.00[76]1.78

[45]

1.62[41]1.67

[42]2.72[69]

C, D, E

EZM113125 / X / CUX, EZM313125 / X / CUXEZMR113125 / X / CUX, EZMR313125 / X / CUXEZMH113125 / X / CUX, EZMH313125 / X / CUX

12.25[311]

2.21[56]

3.75[95]

3.44[87]Typ.

5.20[132]Typ.

7.10[180] 4.79

[122]

2.48[63] 4.59

[117] 7.54[192]10.48[266]12.12[308]

8.50[216]

5.75[146] 2.44

[62]

A, B

6.59[167]

3.00[76]1.78

[45]

1.62[41]1.67

[42]2.72[69]

C, D, E

7.09[180]

48.12[1222]

1.56[40]Typ.

Hanging Mounting Rail

31.30[795]

6.59[167]

EZM114125 / X / CUX, EZM314125 / X / CUXEZMR114125 / X / CUX, EZMR314125 / X / CUXEZMH114125 / X / CUX, EZMH314125 / X / CUX

9.00[229]Typ.

11.19[284]

C, D, E1.65[42]

Page 54: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

54© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

12.25[311]

2.21[56]

3.75[95]

3.44[87]Typ.

5.20[132]Typ.

Omitted on 1Ø Units

9.00[229]Typ.

11.19[284]7.10

[180] 4.79[122]

2.48[63]

4.59[117] 7.54

[192]10.48[266]

1.65[42]

C, D, E

7.09[180]

57.12[1451]

1.56[40]Typ.

6.59[167]

12.12[308]

8.50[216]

5.75[146] 2.44

[62]

A, B

6.59[167]

3.00[76]1.78

[45]

1.62[41]1.67

[42]2.72[69]

C, D, E

EZM115125 / X / CUX, EZM315125 / X / CUXEZMR115125 / X / CUX, EZMR315125 / X / CUXEZMH115125 / X / CUX, EZMH315125 / X / CUX

in.[mm]Dimensions:

Omitted on 1Ø Units

12.25[311]

2.21[56]

3.75[95]

3.44[87]Typ.

5.20[132]Typ.

7.10[180] 4.79

[122]

2.48[63]

4.59[117] 7.54

[192]10.48[266]12.12[308]

8.50[216]

5.75[146] 2.44

[62]

A, B

6.59[167]

3.00[76]1.78

[45]

1.62[41]1.67

[42]2.72[69]

C, D, E

7.09[180]

66.12[1679]

1.56[40]Typ.

Hanging Mounting Rail

40.30[1024]

6.59[167]

EZM116125 / X / CUX, EZM316125 / X / CUXEZMR116125 / X / CUX, EZMR316125 / X / CUXEZMH116125 / X / CUX, EZMH316125 / X / CUX

Hanging Mounting Rail

31.30[795]

9.00[229]Typ.

11.19[284]

C, D, E1.65[42]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

Page 55: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

5507/2008 © 2008 Schneider Electric All Rights Reserved

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

17.38[441] 3.75

[95]

12.23[311]

2.12[54]

6.00[152]

2.18[55]

8.30[211]

5.75[146]6.75[171]

10.50[267]

15.00[381]

2.25[57]

9.00[229]Typ.

17.25[438]

6.59[167] A, B

C, D, E, F

4.12[105]

7.50[190]

1.61[41]

3.34[85]

1.93[49]

EZM112225 / X / CUX, EZM312225 / X / CUXEZM113225 / X / CUX, EZM313225 / X / CUX

EZMR112225 / X / CUX, EZMR312225 / X / CUXEZMR113225 / X / CUX, EZMR313225 / X / CUX|EZMH112225 / X / CUX, EZMH312225 / X / CUXEZMH113225 / X / CUX, EZMH313225 / X / CUX

Omitted on 1Ø Units

Top Meter Position Omitted on 2-Position Devices

3.44[87]Typ.

C, D, E, F

8.09[205]

1.56[40]Typ.

Hanging Mounting Rail

32.34[821]

43.41[1103]

7.50[190]

17.38[442] 3.75

[95]8.09[205]

1.56[40]Typ.

Hanging Mounting Rail

52.00[1321]

3.44[87]Typ. Omitted on

1Ø Units

12.23[311]

2.18[55]

9.00[229]Typ.

C, D, E, F

32.34[821]

7.50[190]

2.12[54]

6.00[152]

5.75[146]6.75[171]

10.50[267]

15.00[381]

2.25[57]

17.25[438]6.59

[167] A, BC, D, E, F

4.18[106]

7.50[190]

1.61[41]3.34[85]

1.93[49]

EZM114225 / X / CUX, EZM314225 / X / CUXEZMR114225 / X / CUX, EZMR314225 / X / CUXEZMH114225 / X / CUX, EZMH314225 / X / CUX

in.[mm]Dimensions:

5.30[211]

Page 56: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

56© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

17.37[441]8.69

[221]1.74[44]

12.73[323]

9.00[229]Typ.

12.21[310]

60.94[1548]

3.44[87]Typ.

25.09[837]

17.25[438]

C, D, E, FKnockouts in Rear of Box

7.53[191]

8.09[208]

28.59[728]

32.35[822]

Top of Mounting Channel

A, B

C, D, E, F2.27[58]

2.18[55]

1.72[44]3.32

[84] 1.66[42] 1.67

[42]

3.32[84]

3.33[85]

2.35[60]

NOTE: Shown with covers removed.

EZM115225 / CU, EZM315225 / CUEZMR115225 / CU, EZMR315225 / CUEZMH115225 / CU, EZMH315225 / CU

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118in.

[mm]Dimensions:

Omitted on 1Ø Units

Page 57: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

5707/2008 © 2008 Schneider Electric All Rights Reserved

19.44[494]12.09[307] 5.50

[140]

6.00[152]

3.44[87]Typ.

3.20[81]

6.62[168]

13.99[355]

13.34[339]

D, E, F, G

Omitted on 1Ø Units

Top Meter Position Omitted on Single Position Device

2.07[53]

3.97[101] 5.86

[149]9.65[245]13.45[342]

17.24[438]

12.09[307]

(See Typical Bottom View)

EZML111225 / CU / D, EZML312225 / CU / DEZML112225 / CU / D, EZML331225 / CU / DEZMR332225 / CU / D, EZML332225 / CU / D

9.44[240]

39.06[992]

Top of Mounting Channel

25.50[648]

8.83[224]

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

19.44[494]12.09[307]

3.44[87]Typ.

14.00[356]Typ.

Omitted on 1Ø Units

5.50[140]

13.34[339]

3.20[81]

6.62[168]

12.09[307]2.07

[53]3.97[101]

5.86[149]

9.65[245]

13.45[342]

17.24[438]

EZML113225 / CU / D, EZML313225 / CU / DEZMR333225 / CU, EZML333225 / CU / D

9.44[240]

53.06[1348]

Top of Mounting Channel

39.50[1003]

8.83[224]

19.44[494]12.09[307] 9.44

[240]

3.44[87]Typ.

5.50[140]

Omitted on 1Ø Units

14.00[356]Typ.

Top of Mounting Channel

67.06[1703]

39.50[1003]

8.83[224]

12.09[307]

3.20[81]

6.62[168]

D, E, F, G

2.07[53]3.97[101] 5.86

[149]9.65[245]

13.45[342]

17.24[438]19.31[490]

A, BD, E, F, G3.91

[99]

4.60[117]

2.00[51]

3.79[96]

2.24[57]

8.83[224]

EZML114225 / CU / D, EZML314225 / CU / DEZMR334225 / CU, EZML334225 / CU / D

(See Typical Bottom View)

Typical Bottom View in.[mm]Dimensions:

13.34[339]

D, E, F, G

Page 58: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

58© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

Knockouts

SymbolConduit Size Hole Diameter

in. [mm] in. [mm]

A 0.50 13 0.88 22

B 0.75 19 1.25 32

C 1.00 25 1.38 35

D 1.25 32 1.75 44

E 1.50 38 2.00 51

F 2.00 51 2.50 64

G 2.50 64 3.00 76

H 3.00 76 3.63 92

I 3.50 89 4.13 105

J 4.00 102 4.63 118

22.42[570]

18.31[465]

2.06[52]

20.45[519]

25.12[638]

9.16[233]

3.44[87]Typ.

C, D, E, F,G, HKnockouts in Rear of Box

9.38[238] 0.38

[10]Top of Mounting Channel

16.19[411]

8.97[228]

1.81[46]

2.77[70]

5.15[131] 22.31

[567]

7.25[184]

8.94[227]

A, B C, D, E, F, G, H

2.30[58]

1.00[25] 3.09

[79]5.78[147]

22.42[570]

18.31[465]

2.06[52]

9.16[233]

3.44[87]Typ.

8.80[224]

1.68[43]

60.56[570]

36.40[925]

C, D, E, F,G, H Knockouts in Rear of Box

4.31[110]

4.27[108]

2.41[61]

22.31[567]

1.80[46]

8.44[214]

28.89[734]

19.00[483]

9.38[238]

0.38[10]

Top of Mounting Channel

43.63[1108]

8.94[227]

2.36[60]

A, BC, D, E, F, G, H

2.41[61] 4.27

[108]

1.40[36]

2.47[63]4.27

[108]

EZMT111225, EZMT311225, EZMT331225

Typical endwall for 2 and 3 positions.

22.42[570] 18.31

[465]

8.80[224]

2.06[52]

19.00[483]

79.56[2021]

3.44[87]Typ.

41.03[1042]

19.00[483]

28.89[734]

8.44[214]

1.81[46]7.25

[184]22.31[567]

4.31[110]

C, D, E, F,G, HKnockouts in Rear of Box

2.41[61] 4.27

[108]Typ.

8.94[227]

48.25[1226]

9.38[238] 0.38

[10]

EZMT113225, EZMT313225, EZMT333225 in.[mm]Dimensions:

1.68[43]

Omitted on 1Ø Units

EZMT112225, EZMT312225, EZMT332225

9.16[233]

Omitted on 1Ø Units

Page 59: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersDimensions and Knockouts

5907/2008 © 2008 Schneider Electric All Rights Reserved

23.21[590]12.09[307] 5.50

[140]

3.44[87]

(Typ.)

21.53[547]16.60

[422]

10.11[257]

9.44[590]

45.55[1157]

37.81[960]

Top of Mounting Channel

23.21[590]12.09[307] 9.44

[240]

14.58[370]

5.50[140]

27.44[697]

3.44[87]

(Typ.)

16.60[422]

10.11[257]

21.53[547]

37.81[960]

Top of Mounting Channel

27.56[700]

15.68[398]

5.82[148]

11.12[282]

1.68[43]

45.55[1157]

21.04[534]

3.44[87]Typ.

30.58[777]

27.48[698]

1.80[46]

9.74[247]

0.34[9]

Top of Mounting Channel

37.81[960]

9.23[235]

Top of MountingChannel

27.56[700]

15.68[398]

11.12[282]

5.82[148]

3.44[87]Typ.

30.58[777]

7.59[193]

72.99[1854]

1.68[43]

29.69[754]

21.04[534]

1.80[46]27.44

[697]

9.74[247]

37.81[960]

9.23[235]

EZMK112400, EZMK312400, EZMK332400

EZMK111400, EZMK311400, EZMK331400

EZML112400, EZML312400, EZML332400

EZML111400, EZML311400, EZML331400

in.[mm]Dimensions:

Omitted on 1Ø Units

69.61[1768]

Omitted on 1Ø Units

0.34[9]

Omitted on 1Ø Units

Omitted on 1Ø Units

NOTE: No knockouts provided on EZMK and 400 A EZML devices.

Page 60: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

60© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Dimensions and Knockouts

14.40[366]

8.02[204] 14.40

[366]

1.80[46] 7.20

[183]

1.69[43]

19.50[495]

Omitted on 1Ø Units

Omitted on 1Ø Units

Omitted on 1Ø Units

Omitted on 1Ø Units

in.[mm]Dimensions:

1.71[43] 11.66

[296]

19.34[491]

1.74[44]

11.50[292]

5.87[149]

6.37[162]

EZM1CORNEREZM3CORNERNEMA Type 1(Indoor Only)

EZM1EXTEZM3EXT

8.07[205]

6.51[165]

6.48[165]

8.06[205]

1.80[46]

1.67[42] 0.34

[9]

EZM1ELBOWEZM3ELBOW

6.00[152]

6.37[162]

5.87[149]

1.71[43]

19.34[491]

1.74[44]

11.50[292]

EZM1EXT6EZM3EXT6

Page 61: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

6107/2008 © 2008 Schneider Electric All Rights Reserved

Wiring Diagrams

AB

CN

N

A B C

N

N

N

N

A

BCN

A B C

N

N

N

A

B

C

A

B

C

N

N

A B C

N

N

Load

Load

Load

Load

Load

Load

Load

Load

Load

Load

CircuitBreaker

CircuitBreaker

CircuitBreaker

CircuitBreaker

CircuitBreaker

CircuitBreaker

Omitted on 400 A DeviceMain Bonding Jumper (when required)

Main Bonding Jumper (when required)

Main Bonding Jumper (when required)

Main Bonding Jumper (when required)

Main Bonding Strap (when required)

Main Bonding Strap (when required)

Omitted on 400 A Device

Omitted on 1200 A Device

Omitted on 1200 A Device

Ground (when required)

Ground (when required)

Ground (when required)

Ground (when required)

Ground (when required)

EZM1400CB, EZM1600CB, EZM1800CB, EZM11000CB

EZM3400CB, EZM3600CB, EZM3800CB, EZM31000CB

Line

Omitted on 1200 A Device

Omitted on 1200 A Device

Line

Line

Line

EZM11200CB, EZM11600CB,

EZM31200CB, EZM31600CB

Load

Ground (when required)

EZM12000CB

Line

EZM32000CB

Load

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Line

Omitted on 400 A DeviceMain Bonding Jumper (when required)

Ground (when required)

EZM1400FS, EZM1600FS, EZM1800FS

Load Load

Line

Page 62: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

62© 2008 Schneider Electric All Rights Reserved 07/2008

ABC

N

N

A B C

N

N

N

N

A

B

C

A B C

N

N

A

BC

A B C N

N

N

N

N

N

Load

Ground (when required)

Ground (when required)

Load

Load

Omitted on 400 A DeviceMain Bonding Jumper (when required)

EZM3400FS, EZM3600FS, EZM3800FS

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Line

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Load

Line

Ground (when required)

Main Bonding Jumper (when required)

EZM11200FS

Ground (when required)

EZM1225TB

Ground (when required)

EZM3225TB

Omitted on 400 Aand 600 A Devices

Ground (when required)

Main Bonding Jumper (when required)

EZM1400TB, EZM1600TB, EZM1800TB, EZM1800TBCU

Omitted on 400 Aand 600 A Devices

Ground (when required)

Main Bonding Jumper (when required)

EZM3400TB, EZM3600TB, EZM3800TB

Main Bonding Jumper (when required)

EZM11600TB

Page 63: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

6307/2008 © 2008 Schneider Electric All Rights Reserved

A

BC

A B C

N

N

N

N

AB

C

N

A B CN

N

N

ABC

N

A B CN

Ground (when required)

Main Bonding Jumper (when required)

EZM31600TB

Load

CircuitBreaker

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Line

Service Grounding Lugs (when required)

EZM1400CBU

CircuitBreaker

Line

EZM3400CBU

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load Load

Load

CircuitBreaker

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM1600CBU, EZM1800CBU

CircuitBreaker

Line

EZM3600CBU, EZM3800CBU

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load Load

Load

Page 64: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

64© 2008 Schneider Electric All Rights Reserved 07/2008

N

N

ABCN

A B CN

N

N

A

B

C

N

A B C

N

N

N

ABC

N

A B C

N

Load

CircuitBreaker

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM11000CBU, EZM11200CBU

CircuitBreaker

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load Load

EZM31000CBU, EZM31200CBU

Load

CircuitBreaker

Load

Ground (when required)

Main Bonding Strap (when required)

EZM11600CBU, EZM12000CBU

CircuitBreaker

Load

Line

Ground (when required)

Main Bonding Strap (when required)

Load

EZM31600CBU, EZM32000CBU

Load

Use 300 VClass T Fuses

(order separately)Molded Case

Switch

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM1400FSU

Load

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM3400FSU

Page 65: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

6507/2008 © 2008 Schneider Electric All Rights Reserved

N

N

AB

CN

A B C

N

N

N

N

N

ABCN

A B C N

N

N

A B C

ABCN

N

A B C

Load

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM1600FSU, EZM1800FSU

Load

Use 300 VClass T Fuses

(order separately)Molded Case

Switch

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM3600FSU, EZM3800FSU

Load

Use 300 VClass T Fuses

(order separately)

Molded CaseSwitch

Line

NeutralDisconnect

LinkBox

Bonding(when

required)Ground

(whenrequired)

Service Grounding Lugs (when required)

Load

EZM11200FSU

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment Grounding Terminal

EZM1400TBU, EZM1800TBU, EZM11200TBU, EZM12000TB

EZM3400TBU, EZM3800TBU, EZM31200TBU, EZM32000TB

Equipment Grounding Terminal

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

LineTorque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

125 A Max.

EZM113125 / X / CUXEZMR113125 / X / CUXEZMH113125 / X / CUX

Equipment Grounding

Equipment Grounding

Neutral andService Ground

Neutral andService Ground

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

125 A Max.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB, BC, and AC, top to bottom.

EZM313125 / X / CUXEZMR313125 / X / CUXEZMH313125 / X / CUX

Box Bonding (when required)

Box Bonding (when required)

Page 66: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

66© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Wiring Diagrams

N

N

N

N

A B C

ABCN

N

A B C

A B C

A B C

A

BCN

N

Line Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

125 A Max.

Equipment GroundingNeutral

EZM114125 / X / CUXEZMR114125 / X / CUXEZMH114125 / X / CUX

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

125 A Max.

Equipment GroundingNeutral

EZM314125 / X / CUXEZMR314125 / X / CUXEZMH314125 / X / CUX

Line Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

125 A Max.

Equipment Grounding

Neutral

EZM115125 / X / CUXEZMR115125 / X / CUXEZMH115125 / X / CUX

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB, BC, AC, and AC, top to bottom.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leavesthe factory phased AB, BC, AC, AB and BC, top to bottom.

TenantCircuit Breaker

125 A Max.

Neutral

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Line

Equipment Grounding

EZM315125 / X / CUXEZMR315125 / X / CUXEZMH315125 / X / CUX

Page 67: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

6707/2008 © 2008 Schneider Electric All Rights Reserved

N

N

ABCN

N

A B C

A B C

N

N

N

N

ABCN

A B C

A B C

N

Line

Line

TenantCircuit Breaker

125 A Max.

TenantCircuit Breaker

125 A Max.

TenantCircuit Breaker

225 A Max.

Line

TenantCircuit Breaker

225 A Max.Tenant

Circuit Breaker225 A Max.

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment GroundingNeutral Equipment

Grounding

Equipment Grounding

Equipment Grounding

Equipment Grounding

EZM116125 / X / CUXEZMR116125 / X / CUXEZMH116125 / X / CUX

EZM316125 / X / CUXEZMR316125 / X / CUXEZMH316125 / X / CUX

EZM112225 / X / CUXEZMR112225 / X / CUXEZMH112225 / X / CUX

EZM113225 / X / CUXEZMR113225 / X / CUXEZMH113225 / X / CUX

EZM312225 / X / CUXEZMR312225 / X / CUXEZMH312225 / X / CUX

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leavesthe factory phased AB, BC, AC, AB, BC and AC, top to bottom.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leavesthe factory phased AB and BC, top to bottom.

Neutral

Neutral

Neutral

Neutral

Page 68: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

68© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Wiring Diagrams

A B C

ABCN

N

A B C

N

A B C

ABCN

N

A B C

N

A B C

A

B

C

N

A B C

Line

TenantCircuit Breaker

225 A Max.

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment Grounding

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leavesthe factory phased AB, BC, AC and AC, top to bottom.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB, BC, and AC, top to bottom.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leavesthe factory phased AB, BC, AC, AB and BC, top to bottom.

EZM313225 / X / CUXEZMR313225 / X / CUXEZMH313225 / X / CUX

EZM114225 / X / CUXEZMR114225 / X / CUXEZMH114225 / X / CUX

EZM115225 / CUEZMR115225 / CUEZMH115225 / CU

EZM315225 / CUEZMR315225 / CUEZMH315225 / CU

EZM314225 / X / CUXEZMR314225 / X / CUXEZMH314225 / X / CUX

Line

Line

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)Line

Equipment Grounding

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Equipment Grounding

TenantCircuit Breaker

225 A Max.

TenantCircuit Breaker

225 A Max.

Neutral

Neutral

Neutral

NeutralNeutral

Page 69: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

6907/2008 © 2008 Schneider Electric All Rights Reserved

N

N

ABCN

A B C

A B C

A

BC

A B

N

C

A C B

ABCN

CBA

CBA

A

BCN

A BC

A B C

A B C

CA B

A

BCN

A B C

A B C

A B C

N

Line

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

EZML112225 / CU / D

Line

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

EZML111225 / CU / D

Line

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Line

TenantCircuit Breaker

225 A Max.

Equipment Grounding

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB and BC,top to bottom.

EZML312225 / CU / D

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

TenantCircuit Breaker

225 A Max.

Line

Equipment Grounding

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB, BC, and AC, top to bottom.

EZML331225 / CU / D

EZML313225 / CU / D

High Leg (Power Leg)for 3φ4W Delta System

(All Tenant CircuitBreaker Positions)

Line

TenantCircuit Breaker

225 A Max.

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

Equipment Grounding

EZML33225 / CU / DEZML33225 / CU

High Leg(Power Leg) for

3φ4W DeltaSystem (All

Tenant CircuitBreaker

Positions)

Line

TenantCircuit Breaker

225 A Max.

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

Equipment Grounding

EZML333225 / CU / DEZMR333225 / CU

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment Grounding

TenantCircuit Breaker

225 A Max.

EZML113225 / CU / D

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

NeutralNeutral

Page 70: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

70© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Wiring Diagrams

N

A B C

ABC

N A B C

A BC

A

BCN

A B C

A B C

A B C

A B C

N

N

A B C

ABCN

A B C

A B C

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment Grounding

TenantCircuit Breaker

225 A Max.

EZML114225 / CU / D

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Line

Equipment Grounding

EZML314225 / CU / D

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Line

Equipment Grounding

EZML334225 / CU / DEZMR334225 / CU

TenantCircuit Breaker

225 A Max.

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

High Leg (PowerLeg) for 3φ4W

Delta System (AllTenant Circuit

BreakerPositions)

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB, BC, and AC, top to bottom.

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AC.

LineTorque to 50 lb-ft. (600 lb-in. or 68 N•m)

Equipment Grounding Terminal

Service Grounding Lugs when Required

Neutral Terminals

Box Bonding (when required)

EZMT111225

Line

Equipment Grounding Terminal

Service Grounding Lugs when Required

Neutral Terminals

Box Bonding (when required)

NOTE: This device is shipped with line side meter socket bus connectors phased Aφ and Cφ. These connectors may be moved to balance loading for Bφ and Cφ, or for Aφ and Bφ phasing in the field.

EZMT311225

TenantCircuit Breaker

225 A Max.

TenantCircuit Breaker

225 A Max.

TenantCircuit Breaker

225 A Max.

NeutralNeutral

Neutral

Page 71: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

7107/2008 © 2008 Schneider Electric All Rights Reserved

CA B

ABCN

CA B

CA B

C

AB

NA B C

N

N

N

LINE

LINE

LINE

LINE

LOAD

LOAD

LOAD

LOAD

ABCN

A C B

A BC

A B C

LINE

LINE

LINE

LOAD

LOAD

LOAD

Line

Line Line

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

400 A Max.

TenantCircuit Breaker

400 A Max.

Equipment Grounding

Equipment Grounding

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AC.

EZML311400

High Leg (Power Leg) for 3φ4W Delta System

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

EZML331400

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)LineHigh Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System

Equipment GroundingTerminal

Service Ground Lugs (when required)

Neutral TerminalBox Bonding (when required)

EZMT331225

Box Bonding (when required)

Service Ground Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Equipment GroundingTerminal

EZMT112225

TenantCircuit Breaker

225 A Max.

Neutral

N

NeutralN

Page 72: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

72© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Wiring Diagrams

A B CABCN

A B C

N

A B

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

B CN

A B C

ABCN

A C B

A B

C

N

A B

C

N

A BC

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

A B C

A B C

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

LineTorque to 50 lb-ft. (600 lb-in. or 68 N•m)

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. This device leaves the factory phased AB and BC top to bottom.

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System (All Tenant Circuit Breaker Positions)

Box Bonding (when required)

Service Ground Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Equipment GroundingTerminal

High Leg (Power Leg) for 3φ4W Delta System

EZMT312225

High Leg (Power Leg) for 3φ4W Delta System (All Meter Positions)

Box Bonding (when required)Service Ground Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Equipment Grounding Terminal

EZMT332225

TenantCircuit Breaker

225 A Max.

TenantCircuit Breaker

225 A Max.

Page 73: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

7307/2008 © 2008 Schneider Electric All Rights Reserved

N

N

N

N

LINE

LINE

LOAD

LOAD

LINE

LINE

LOAD

LOAD

LINE

LINE

LOAD

LOAD

A CB

A B

A B

N

ABCN

B CN

B C

BA C

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

A C

B CA

A CN

A B

A B

A B

ABCN

C

C

C

N

N

N

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

LINE

LOAD

A B C

A B C

A B C

N

Line Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Box Bonding (when required)

Service Grounding Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Box Bonding (when required)

Service Grounding Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Box Bonding (when required)

Service Grounding Lugs (when required)

Neutral Disconnect Link

Neutral Terminals

Equipment Grounding Terminal

EZMT113225

Each socket line connector may be moved to balance loading. Phase AC, BC or AB. This device leaves the factory phased AB, BC and AC top to bottom.

EZMT313225

Equipment Grounding Terminal

Line LineTorque to 50 lb-ft. (600 lb-in. or 68 N•m)

EZML111400

EZMT333225

High Leg (Power Leg) for 3φ4W Delta System (All Tenant Circuit Breaker Positions)

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System (All Meter Positions)

Tenant Circuit Breaker 225 A Max.

High Leg (Power Leg) for 3φ4W Delta System

Line

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Tenant Circuit Breaker 225 A Max. Equipment Grounding Terminal

EquipmentGrounding

Line

LineTorque to 50 lb-ft. (600 lb-in. or 68 N•m)

TenantCircuit Breaker

225 A Max.

TenantCircuit Breaker

225 A Max.

TenantCircuit

Breaker400 AMax.

Neutral

Page 74: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

74© 2008 Schneider Electric All Rights Reserved 07/2008

EZ Meter-Pak® Meter Centers Wiring Diagrams

N

ABCN

AC

B

A CB

N

N

ABC

A C

N

N

A B C

ABCN

AB

C

C BA

A B C

A B C

ABCN

AC

B

EZML112400

EZMK331400

EZMK311400

EZMK111400

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

Line Line

Line Line

Line Line

Line Line

High Leg (Power Leg) for 3φ4W Delta System

Equipment GroundingTerminal

Equipment Grounding Terminal

Equipment GroundingTerminal

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)High Leg (Power Leg) for 3φ4W Delta System

K-7 Bolt-On Meter Socket

K-4 Bolt-On Meter Socket

K-5 Bolt-On Meter Socket

Each socket line connector may be moved to balance loading. Phase AC, BC, or AB. (B phase line connector is provided). This device leaves the factory phased AC.

K-4 Bolt-On Meter Socket

Equipment GroundingTerminal

Line Line

K-5 Bolt-On Meter Socket

Tenant Circuit Breaker 400 A Max.

Equipment GroundingTerminal

Tenant Circuit Breaker 400 A Max.

Line Line

EZMK112400

EZMK312400

High Leg (Power Leg) for 3φ4W Delta System (Both Tenant Circuit Breaker Positions)

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

EZMK332400

High Leg (Power Leg) for 3φ4W Delta System

Torque to 50 lb-ft. (600 lb-in. or 68 N•m)

Line Line

Equipment GroundingTerminal

K-7 Bolt-On Meter Socket

High Leg (Power Leg) for 3φ4W Delta System

High Leg (Power Leg) for 3φ4W Delta System(Both Tenant Circuit Breaker Positions)

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

Tenant Circuit Breaker 400 A Max.

Each meter socket line connector may be moved to balance loading. Phasing may be connected AC, BC, or AB. This device leaves the factory phased AB and BC top to bottom.

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Page 75: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

EZ Meter-Pak® Meter CentersWiring Diagrams

7507/2008 © 2008 Schneider Electric All Rights Reserved

Page 76: EZ Meter-Pak Meter Centers - DDS (Distributor Data Solutions) · 2020. 7. 7. · EZ Meter-Pak 225–2000 A Main Lugs Terminal Box Applications Protected By Remote Main—See Figure

4100CT0701 © 2008 Schneider Electric All Rights Reserved Replaces 4100CT9801 dated May 1999.

1601 Mercer RoadLexington, KY 40511 USA1-888-Square D1-888-778-2733www.us.SquareD.com

07/2008

Schneider Electric USASquare D, EZ Meter-Pak, Visi-Tite, and QO are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Other marks used herein are the property of their respective owners.