ethernet temperature & humidity data logger for remote monitoring

7
14 May 2015 Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected] www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India Ethernet Temperature & Humidity Data Logger for remote monitoring Features >> Measure and Record 2 Temperature Readings Using External Sensors >> -40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy >> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser >> Free WebStorage Service, WebViewer and Current Readings Monitor Software Included >>Phone call, Email & SMS alert system (optional) >> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory >> User-Configurable Sampling Rate: 1 Second to 1 Hour >> Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor >> AC Powered with Battery Backup for Power Failures and Emergency Use Only >> Automatic Sending of Measured Readings via FTP or E-mail Specifications TR-701NW / 701AW TR-702NW / 702AW TR-702NW-H / 702AW-H Temperature/Humidity Sensor (External) TR-0106 THA-3151 HHA-3151(High-Precision Type) Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units °C, °F °C, °F %RH °C, °F %RH Measurement Range -40 to 110°C(Supplied Sensor) -60 to 155°C(Optional Sensor: Fluoropolymer Coated Type) 0 to 55°C 10 to 95%RH -30 to 80°C 0 to 99%RH Accuracy Avg. ±0.3°C [- 20 to 80°C] Avg. ±0.5°C [- 40 to -20 / 80 to 110°C] ±0.5°C ±5%RH [at 25°C, 50%RH] ±0.3°C [0 to 50°C] ±0.5°C [at all other temperatures] ±2.5%RH [at 25°C, 10 to 85%RH] ±4.0%RH [at 25°C, 0 to 10%RH or 85 to 99%RH] At temperatures other than 25°C and ≥ 0°C, add ±0.1%RH per degree of difference from 25. Humidity Hysteresis: ±1.5%RH or lower *1 Measurement Resolution 0.1°C 0.1°C 1%RH 0.1°C 0.1%RH Responsiveness Thermal Time Constant: Approx. 75sec. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 20sec.

Upload: vackerglobal

Post on 30-Dec-2015

38 views

Category:

Documents


0 download

DESCRIPTION

Measure and Record 2 Temperature Readings Using External Sensors\n-40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy\n Configure, Setup and Manage Data Loggers over an Internet Connection and Browser\nFree WebStorage Service, WebViewer and Current Readings Monitor Software IncludedPhone call, Email & SMS alert system (optional)\n Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory\nUser-Configurable Sampling Rate: 1 Second to 1 Hour\nEmail Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor\nAC Powered with Battery Backup for Power Failures and Emergency Use Only \nAutomatic Sending of Measured Readings via FTP or E-mail\n - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

Ethernet Temperature & Humidity Data Logger for remote monitoring

Features

>> Measure and Record 2 Temperature Readings Using External Sensors

>> -40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy

>> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser

>> Free WebStorage Service, WebViewer and Current Readings Monitor Software Included

>>Phone call, Email & SMS alert system (optional)

>> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory

>> User-Configurable Sampling Rate: 1 Second to 1 Hour

>> Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor

>> AC Powered with Battery Backup for Power Failures and Emergency Use Only

>> Automatic Sending of Measured Readings via FTP or E-mail

Specifications

TR-701NW /

701AW TR-702NW / 702AW TR-702NW-H / 702AW-H

Temperature/Humidity Sensor (External)

TR-0106 THA-3151 HHA-3151(High-Precision Type)

Thermistor Thermistor Polymer Resistance

Platinum Resistance

Electrostatic Capacitance

Measurement Channels

Temperature 2ch

Temperature 1ch

Humidity 1ch

Temperature 1ch

Humidity 1ch

Measurement Units °C, °F °C, °F %RH °C, °F %RH

Measurement Range

-40 to 110°C(Supplied Sensor) -60 to 155°C(Optional Sensor: Fluoropolymer Coated Type)

0 to 55°C 10 to 95%RH

-30 to 80°C 0 to 99%RH

Accuracy

Avg. ±0.3°C [-20 to 80°C] Avg. ±0.5°C [-40 to -20 / 80 to 110°C]

±0.5°C ±5%RH [at 25°C, 50%RH]

±0.3°C [0 to 50°C] ±0.5°C [at all other temperatures]

±2.5%RH [at 25°C, 10 to 85%RH] ±4.0%RH [at 25°C, 0 to 10%RH or 85 to 99%RH] At temperatures other than 25°C and ≥ 0°C, add ±0.1%RH per degree of difference from 25. Humidity Hysteresis: ±1.5%RH or lower *1

Measurement Resolution

0.1°C 0.1°C 1%RH 0.1°C 0.1%RH

Responsiveness Thermal Time Constant: Approx. 75sec.

Response Time (90%): Approx. 7min.

Response Time (90%): Approx. 7min.

Response Time (90%): Approx. 20sec.

Page 2: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

Response Time (90%): Approx. 190sec.

Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)

Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.

Recording Mode Endless (Overwrite oldest data when capacity is full)

LCD Display Items Measurements (alternating display), Power Warning Mark, etc.

Communication Interfaces

TR-701NW / 702NW: Wired LAN RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X TR-701AW / 702AW: Wireless LAN Internal wireless LAN antenna IEEE 802.11b/g

WEP(64bit/128bit) / WPA-TKIP/WPA2-AES

USB Communication (For Setup)

External Alarm Terminal

<Output Terminal: Photo Mos Relay Output> Voltage when OFF: AC/DC less than 50V Current when ON: less than 0.1A Resistance when ON: about 35Ω

Communications Protocol

HTTP, SMTP (POP before SMTP, SMTP-AUTH <LOGIN>), FTP, SNTP, DHCP, DNS

Power Main Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type Lithium Battery (CR-2032) *2

Data Backup *3 Approx. 3 months (backup battery CR-2032 only without AC adaptor)

Dimensions H 55 mm x W 78 mm x D 37 mm

Weight TR-701NW / 702NW / 702NW-H : approx. 82 g TR-701AW / 702AW / 702AW-H : approx. 80 g (including battery, excluding sensor)

Operating Environment

Temperature: -10 to 60°C Humidity: 90 %RH or less (no condensation)

Accessories

Temperature Sensor (TR-0106) x 2

Temperature/Humidity Sensor (THA-3151) x 1

High Precision Temperature/Humidity Sensor (HHA-3151) x 1

USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW / 702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery (CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1

Supported Browsers

<Desktop Browser> Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later) <Mobile Browser> Safari (iOS), Chrome (iOS, Android), Firefox (Android)

*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.

*2: The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot occur when using only the battery.

*3: Battery life varies depending upon the ambient temperature and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.

Use via Network Connection

The TR-700W Series Loggers allow you to make device settings, monitor current readings, gather recorded data and an array of other functions via LAN or Internet connection. The USB connection also allows for settings including wired LAN and wireless LAN settings to be made directly from a PC.

Page 3: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

Various Monitoring Functions

Using "WebViewer":

The TR-700W Series WebViewer application enables the viewing of data graphs in your browser. In the browser you can not only view graphs and current readings, but also settings information for the target TR-700W Series device.

Using "T&D WebStorage Service":

As long as you have access to the Internet, our "T&D WebStorage Service" is available; thus bringing you "anytime anywhere" access to your recorded data for monitoring, saving, analyzing, printing, and so on. This service also allows for the viewing, sharing and usage of data by multiple parties across distances at the same time, thus providing increased management efficiency.

Page 4: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

Via "Current Readings Monitor":

The "Current Readings Monitor" application included in the software package allows not only for the management of current readings, but also provides a way to manage all devices registered on the same network.

Via Mobile Device:

Both "WebViewer" and "T&D WebStorage Service" can be used with mobile devices such as smart phones and tablets, enabling easier access to data anytime, anywhere.

Page 5: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

Efficient Warning Monitoring Functions

It is possible to have warning report e-mails sent when user set conditions have been met. Warning report mails can be sent when an upper and/or lower limits have been exceeded, when a sensor error has occurred or when there has been a recovery from one of the set warning conditions. Also, by connecting a warning device to the external contact output terminal, it is possible to receive notification of a warning by buzzer, siren, lamp, or other electromagnetic contactor. It is also possible to select whether or not to have the external warning coupled with a warning report mail.

Auto-Sending of Measurements

Using Device Settings for TR-700W Series Data Logger:

By making settings in the device it is possible to automatically have Recorded Data and/or Current Readings sent periodically via FTP or e-mail without the need for PC.

Using the "Current Readings Monitor":

If a server is not available, it is possible to use the "Current Readings Monitor" application to have recorded data automatically saved.

Page 6: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

High-Performance User Friendly Graph Software Available

Our newly designed software "T&D Graph" gives you greater management and analyzing power for dealing with the recorded data (TRZ format) collected from TR-700W Series loggers. "T&D Graph" allows you to read larger numbers of recorded data files (TRZ format) into the same graph, merge data, view and save data various ways. It can be downloaded free of charge at theT&D Website.

This versatile graph tool not only allows the user to directly access data stored in the WebStorage Service, but the user can also specify conditions such as time period for which data to view and analyze. It is also possible to sample and filter data, add memos and write comments directly on the graph, as well as, save data to CSV Format for use with common spreadsheet software.

Page 7: Ethernet Temperature & Humidity Data Logger for remote monitoring

14 May 2015

Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:[email protected]

www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

All images and data above are copyrighted to the manufacturer T&D corporation, Japan

Videos:

Functioning demo : http://bit.ly/1jZAJRe

Remote monitoring software demo : http://bit.ly/1srWvh8