established 19 8 1 monitor & record 10.20, or 30 … time, full-size waveform monitor ......

10
MONITOR&RECORD 10 .20,or30CHANNELS WITHASTRO-MED'SALL-NEWPORTABLERECORDER TruePortability :InternalBattery,ACandDCPower Big,Bright,High-ResponseMonitorforViewing DataandEasySetups LaserQualityChartResolution(300dpi) 50mVto500VDCIsolatedInput - DCto25kHz Response Huge512kSampleMemory perChannelforDataCapture andAnalysis 1 .44MByteFloppyDrivefor QuickRecorderSetups,Data StorageandUpgrades Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ® E s t a blishe d 1 9 8 1

Upload: dinhnhi

Post on 25-Mar-2018

217 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

MONITOR & RECORD10.20, or 30 CHANNELSWITH ASTRO-MED'S ALL-NEW PORTABLE RECORDER•

True Portability: Internal Battery, AC and DC Power•

Big, Bright, High-Response Monitor for ViewingData and Easy Setups

Laser Quality Chart Resolution (300 dpi)•

50 mV to 500 VDC Isolated Input - DC to 25 kHzResponse

Huge 512 kSample Memoryper Channel for Data Captureand Analysis

1 .44 MByte Floppy Drive forQuick Recorder Setups, DataStorage and Upgrades

Advanced Test Equipment Rentalswww.atecorp.com 800-404-ATEC (2832)

®

Established 1981

Page 2: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

Astro Med's AllNew Dash 10 Field and Lab Recorder

RECORD ALL YOUR DATA WITH THE DASH 10

When your job calls for recording 10 to 30 waveform channels,your only choice is Astro-ltled's all-new Dash 10 . Its internal bat-tery power gives you true portability . Just pick it up and carry itanywhere. You get 11-inch wide, 300 dot per inch 'laser quality''charts. You can view \N-aveforms in real time on a bright, highresponse vacuum fluorescent (VF) monitor while recording orduring setups .

The Dash 10 allows you to input full scale signals from 50 mV to500 V peak (250 V RMMS) at frequencies to 25 kHz without the needfor external signal conditioners .You can capture up to 512 kSamples of data per channel to the

huge internal RAM memory for up to 30 channels simultaneously .Also, the 1 .44 MMByte DOS compatible floppy drive makes recordersetups, data storage and software upgrades quick and easy .

Up to 30 Input ChannelsThe Dash 10 comes with ten

isolated analog waveform inputchannels and is expandable to 30channels in increments of 10 .Included are one event (logic)channel for each waveform plus a"system" event and two tri-leveltine markers. Built-in signal condi-tioners accept signals from 50 nmVto 500 V peak (250 V RMIS), with± 250 V of zero suppression andisolated inputs, eliminating theneed for external amplifiers .

Real Time, Full-Size WaveformMonitor

The Dash 10 displays waveformsin real time on a bright . fast, vacuumfluorescent (VF) monitor . You can seewaveform activity as it happens-

even from across the room, elim-inating any recorder viewing delay.Now the data is always visible - atany chart speed . And, since the VFdisplay has a 100 Hz refresh rate,you can see high frequency signalsclearly.

A Truly Portable Field and LabRecorder

The Dash 10, a truly portablerecorder, features a built-in battery,which allows it to be used at remotesites. In the lab, the battery alsofunctions as a UPS (uninterruptiblepower supply) . The battery iseasily accessible by simply slidingoff a cover plate, and it takes only

t-imGuarded binding post type inputs(banana compatible), standard with theDash 10, are available to accommodate10, 20 or 30 channels.

Fhst, brilliant vacuum fZuovesaent monitor with 100 Hz rV~nh rate displayshigh frequency signals clearly in real time. The monitor also displays recordermenus for paperless setups .

© Astro-Med, Inc ., 1994

Page 3: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

an instant to snap in a fresh one.Battery replacement is so easy thatit makes sense to bring extrabatteries along on those long fieldtrips. What's more, the batteryautomatically recharges wheneverthe Dash 10 is plugged in! TheDash 10, supplied with an integralshoulder strap and a soft-sidedcarrying case, is comfortable andeasy to carry to a recording site .

Only Astro-Med's portable recorders offerinternal batteries, making them at harmin the field; lab, or on a factoryfoor.

Laser Sharp, 11-Inch WideCharts

The Dash 10 and Astro-Med'sDash N are the only portablerecorders in the world with300 dot-per-inch print engines,which provide laser-sharp,er-sharp,accurate charts.

Astro-Med's 300 dpi print enginepermits 50 % better resolutionalong the important amplitude axiscompared to old style 200 dpimachines. It achieves 300 x 300dpi laser printer resolution at upto 100 mm/sec, producing theclearest, sharpest, most accuratetraces you've ever seen .And the 11-inch wide chart

provides plenty of space for wave-forms, even when recording 30channels!

Completely Flexible ChartLayoutThe Dash 10 gives you total

control over chart layout andannotation. without rigid pre-formatted grids and annotationchannels. You can set individualchannel widths, channel locations,grid on 'off and major and minordivision sizing as well as annotationcontent and location .

Every unique test setup can besaved to floppy disk using the 1 .44NIB internal floppy disk drivestandard with the Dash 10. Simplyprogram the recorder once, thensave the setup to disk . The nexttime you need that format, simplyslip the disk into the drive, andyou're ready to record . You canstore up to 20 different setups onone disk .

Built-in Floppy Disk DriveIn addition to storing complete

recorder setups, yon can use thefront panel floppy drive to upgradesystem software and to store datacollected with the optional RAMmemory. This capability lets youcapture data in the field and send itback to the lab on disk for reviewand analysis on a PC .

Encoder Wheel simplifies aiul allows quick, accurateparctnceteradjusttrtent . I oreforrn position, channelwidth, precisegain, etc . can be carb'd it) s'% •oods .

1 .44 _11L3yte DOS corn patible,floppy d ri ne,slaaida,d with Dash 10, offers Wealth ofdata nianageinentcapabilities, includingstorage oj' up to 20 different chart set ups ;storage of data for archiving or for a nalysis ;download of modified data forplctybackanl ntonitorand hard whit output ;andfor installation ofsgftii a . ., ,upgrades.

Page 4: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

Astro-Med's All New Dash 10 Field and Lab Recorder

4

CREATION OF THEPERFECT (HART

The true measure of a recorder is the quality of the chart it pro-duces. The chart must be clear, crisp, easy to read, and accurate .The Dash 10 uses a print engine with laser resolution along withadvanced electronics and software to give you charts that are asbeautiful as they are accurate and complete with all the informa-tion needed for immediate analysis of test results .

Lay Out 10, 20 or Even 30 Channels Anywhere on the ChartThe Dash 10 gives you complete command of your data format .

Up to 30 waveform channels can be placed at any location youselect on the chart, and the grid for each waveform can be inde-pendently configured to suit your needs . Make the grids any sizeyou want, and select the size and number of major and minordivisions .

The Dash 10 provides one event marker per channel plus thesystem event channel . You can position the event markers any-where on the chart . For example, they can be grouped in a specialsection or placed alongside the corresponding waveform channel .

Calibrate the Chart in Engineering UnitsThe new Dash 10 can calibrate any grid in user-defined engi-

neering units as well as the traditional voltage scale . iou canoverprint the chart directly with scale values such as °C or °F. psi,mmHg, ft-lb, or any scale that suits your application .When you choose to annotate the chart in engineering units . you

get more than just custom chart calibration . All chart annotations- all menus. grid minimum and maximum values. even the gainand zero suppression position - arc displayed and printed in yourown engineering units .

Five Types of Alphanumeric AnnotationThe Dash 10 offers five different types of alphanumeric annota-

tion to provide a complete description of your test results :(1) The System Loog, a single line containing the time, date . chart

speed, time mark setting and operating mode. i s located on the topmargin of the chart .

(2) Up to 30 Channel Artootatiori Bufffeix, one per channel,provide a 128-character, alphanumeric, user-defined message thatspecifically describes the significant characteristics of eachchannel .

(3) Ga,irr Setting Conditions are printed automatically for eachwaveform channel .

(4) One Ote-Demand Prioting Bofjerallows you to print one lineof 128 characters anywhere on the chart .

(5) Gh,a,neel ID labels each waveform with its channel numberand full scale top and bottom grid values in either voltage or yourspecified engineering units .

Multiple Recording FormatsIn addition to the familiar waveform format . the Dash 10 gives

you many different ways to view your data . For example, the DataLogger mode presents your data (10 channels at a time) in numericvalues with your choice of engineering units. In this mode it printseach point as a signed. fivedigit value with decimal and afour character label to identify your units .

The Dash 10 can also operate as a line printer under host con-trol, with data printed at up to 50 mm, second .

With optional data capture installed, data can he played back inX -Y plots or analyzed with the FF'T utility program .

ov • nam

1 0 1

;d•

0

L7N

W-

OA

> N • Mto Z {

;0

2 bri o7 • >0

co >•

v N

Z X

C)

a

Page 5: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

8 m6

mL7

z•

*0

~•

-

Z

Ct

m Xr~- zZ

C~ A

I

•to

0

0

d

9Z

i ~~ ~ er rr atr;orr recorded by t{r )aslr 10 1>rcl rsi-s r>rfe>Clurciiel uiarrt~tutio~r 6zr-t,~~ers1r11~ical chart ill ustiatcs the wide rcrirge~fuse-/'u! - r f

,~

1 _

cn -d,' - i•i a

withsysleiir airiiotati~rrr channel, s ;±iste>i'n enE>>tt chtt>anel, o» rL

nci uizrzotat`rr~rr brcf/'er, channel 11)arzd y,1r d labeling .

-All printed laser equality resolalion.

b

Page 6: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to
Page 7: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

Shoulder Strapfor EasyTransport

Built-in SignalConditioners

Bright. HighSpeed VacuumFluorescentMonitor

Internal Battery

300 dpi PrintEngineProducesCrystal ClearTraces

Wide 11-InchChart

CalibrationSource -- >>

Utility Pbrt forExternalControl ofrigger,Start/Stop, .-rRemote ChartDrive andSystem Event

SPECIAL FEATURES OF THE DASH 10

RS-232 Pbrt Event Inputs GPIB Pbrt

10, 20 or '30WaveformChannels

CompleteAlphanumericKeypad lbr Easy

/ Entry ofAnnotationData

Encoder WheelPermits Quick,AccurateParameterAdjustment

DOSCompatible1 .44 MB FloppyDrive

ChartAnnotation inVolts or User-DefinedEngineeringUnits

9

Page 8: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to
Page 9: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

AnnotationUnitsAll annotation can be selected

in either voltage or in user-defined engineering units

System LogSingle line containing thetime, date, chart speed andtime mark setting

Channel Annotation . . . .Each channel has a128-character ASCII buffer

Signal ConditionerUses last 32 characters ofchannel annotation if enabled

On-DemandAnnotation128 character buffer printed

anywhere on the chartChannel IDEach channel is labeled with

channel number on demand .Full scale top and bottomvalues of the grid can beprinted in either voltage orengineering units

Time Lines and MarkersTri-State Markings( x 1, x 10, x 100) mark on

left, right or both edgesHorizontal Grid Lines . . .Alay be synchronized to time

markTime Mark Intervals . . . .0 .02, 0.04. 0 .1, 0 .5 or 1

second (x 1 set titig)Manual Event MarkFront panel key or external

(TTL or switch closure), choiceof bar on off or binary level

External TimeMarksUp to 30 event marks avail-

able (TTL or switch closure),non-isolated, glitch capture

Power/Environmental/DimensionalGeneralStandard AC, DC or optional

internal batteryAC Requirement120' 240 VAC nominal at 50 or

60 HzDC Requirement11-18 VDCOperatingTemperature0°C to 40°C

Storage Temperature0°C to 80°CRelative Humidity0 t o 95 , non-condensingOverall Dimensions5" (127 mm) H x 20" (508

nun) D x 18" (457 mm) WVWeight36 lbs (16 kg) with battery : 32

lbs (15 kg) without (10channel)

OptionsData CaptureGeneralEach channel can capture up

to 512 kSamples of data toRA-%1 during one capture .Captures can be stacked in 64kSample blocks or memorycan be linked for a total of 5Mlegasamples (per 10 chan-nels) . Events are alsocaptured .

Background Capture . . . .StandardMemoryDRAMTime StampingAll records are time stamped

at time of triggerSample Rates10 to 250 kSamples per

second per channelRecord Sizes64 kSamples/channel

(stacked): 512 kSamples ;'channel (not stacked orlinked) ; 5 Mlegasamples(linked, 1 channel captureper 10 channels)

StackingUp to 8 records can bestacked . Stack up to eight 64kSample blocks per channel

HeaderEach record containscomplete capture informationincluding analog settings

TriggerManualWith front panel keyHostRS-232 or GPIRPeriodicUser programmed, internal% veformInside window. outside

window, above level, belowlevel . AND ()I? combinations

BatteryGeneralFits inside the Dash 10 and

charges automaticallywhenever unit is connected toexternal power. Ideal for fielduse and in the lab as a UPS .

Battery Life1 hour, nominalBattery Charge Time . . .15 hours

8

Page 10: Established 19 8 1 MONITOR & RECORD 10.20, or 30 … Time, Full-Size Waveform Monitor ... specifically describes the significant characteristics of ... Storage Temperature 0°C to

i ∎

MORE WAYS TO FULFILL YOUR RECORDING REQUIREMENTS

MT95K2, today's most powerful and versatile recorder,can perform range of tasks that previously required a bat-tery of instruments . User can view up to 32 waveforms onbright built-in monitor while recording analog or digitalwaveform channels at real-time frequencies to 20 kHz .Features laser printer chart resolution of 300 dpi . Offersthree on-board analysis functions and Windows analysispackage for PC .

Portable 4-Channel Recorder with Laser Resolution

Dash IV true field recorder features laser printer chartresolution, bright high-response VF monitor, 140 mmchart, and 128 kSample memory per channel for datacapture and analysis . Records from 50 mV to 350 V'DC(isolated) at 20 kHz response . Internal rechargeable bat-tery (and AC) provides true portability. Powerful softwarepackage permits data analysis with FFT, etc. Includes anon-board floppy drive for setups, updates and dataarchiving.

At the Summit of Chart Recording

Astro-Med; Inc.World HeadquartersAstro-Med Industrial Park,West Warwick,Rhode Island 02893 U.S.A .Phone (401) 828-4000Fax : (401) 822-2430

7bll-Free Phone (U.S.A . only):(800) 343-4039

Truly Portable 8-Channel Recorder

Dash 8 is world's only truly portable 8-channel lab andfield recorder. Records 8 channels of waveform data, 8event, and 8 alphanumeric channels on 8'/2-inch chart .Frequency response DC to 25 kHz real time . Permits crea-tion of custom chart formats "on the fly." Powered byinternal rechargeable battery, AC and 12 VDC . Data cap-ture and playback - 32 kSamples per channel . Weighsonly 28 lbs including internal battery .

Rugged, Powerful 2-Channel Field Recorder

Dash II is world's toughest, most powerful 2-channelportable field recorder. Built for reliable operation underdemanding physical and environmental conditions . Fea-tures frequency response to 500 Hz full scale and a widerange of signal conditioners for voltage, transducer, tem-perature, etc. Records separate or overlapping waveforms .Internal rechargeable battery, AC or 12 VDC operation .

CANADA • Astro-Med, Inc ., 1205, rue Ampere, Suite 100Boucherville, Quebec J4B 7M6 • TN . (514) 449-2727 • Fax (514) 449-2755Toll-Free 1-800-565-2216 (Canada Only)

UNITED KINGDOM • Astro-Med House, 11 Whittle Parkway,Slough, SL1 6DQ'1N . (0628) 668836 • Fax (0628) 664994FRANCE • Astro-Med SNC, Parc d'Activites de Pissaloup,1, rue Edouard Branly, 78190 TrappesTel . (1) 34 .82.09.00 • Fax (1) 34.82 .05 .71

GERMANY • Astro-Med GmbH, Senefelderstra1be 1, D-631 10 RodgauTel . 06106/75033 • Fax 06106/73565ITALY • Astro-Med S.R.L ., Via Plezzo 8, 20132 MilanoTel . (02) 26411909 • Fax (02) 26412828

Representatives and distributors located throughout the world

Printed in U .S.A .