esmpro customer presentation
TRANSCRIPT
![Page 1: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/1.jpg)
NEC Confidential© NEC Corporation 2009
NEC Express serversManagement tools
G.MICHONSenior Manager Pre-salesServer & Storage solutions
![Page 2: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/2.jpg)
NEC Confidential
NEC Management framework
MasterScope is a series of Integrated System Management software products which simplify day-to-day operations and control whole IT infrastucture
Operations Management
Job Management Software Deployment Platform Optimization Backup
JobCenter Deployment Manager SigmaSystemCenterNetworker/ NetVault/
NetBackUp
System Management
System Management Network Management Storage Management App Management
System ManagerOperations Navigator Network Manager StorageManager Application Navigator
MISSION CRITICAL OPERATIONS
Unified Management
Corporate Management
IT Service Level Management
Invariant Analyzer
Server & Storage Management (Hardware)
ESMPRO ManagerStorage Manager
![Page 3: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/3.jpg)
NEC Confidential
Integrated mgmtMasterScope MCO
NW monitoring
Resourcemonitoring
Service,Process monitoring
HW monitoring
Log monitoring
Server alive monitoring by ICPM and SNMP trap monitoring
Check the running status by monitoring up down status of Windows service and process
Monitor logs from OS and AP and detect abnormal situation
Monitor threshold of OS performance (remaining CPU, memory, disk etc).
Monitor performance information of middleware soft (DB, AP server, Web server etc). Monitor service level of certain protocols
Application mgmtMasterScope Application Navigator
Server mgmtMasterScope SystemManager
Network mgmtMasterScope Network Manager
Target layer
Storage monitoring Storage mgmt tool for running status and config mgmt.
Storage mgmtMasterScope StorageManager
Detects HW failure HDD, fan,.), component status changeRemote Control
Server HW mgmtESMPRO Manager
Monitoring points Product lineup
AP performance monitoring
Today Focus
NEC Management framework
![Page 4: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/4.jpg)
NEC Confidential4
ESMPRO Manager version 5
![Page 5: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/5.jpg)
NEC Confidential5
ESMPRO5 Server Management Overview
At a glance
Management solution for NEC Express5800 servers
Bundled with Express5800 servers (Express Builder CD-ROM)
Centralized and distributed management of NEC Express servers
Management Features
Real-time monitoring
Hardware components status
Software information (Firmware/OS)
Alert management (Hardware failure/status change)
Performance/usage monitoring
Power control & monitoring
Remote control operations (Power, Logs, Batch, ..)
Integration with other frameworks (HP Open-View, Microsoft MOM, Nagios ..)
![Page 6: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/6.jpg)
NEC Confidential6
Server Infrastucture monitoring
NEC Express5800Servers
ESMPROManager
WEB-based Manager
InternetIntranet
ESMPRO agents(SNMP)
![Page 7: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/7.jpg)
NEC Confidential7
Server hardware monitoring
Hardware failureComponent status change
ESMPROManager
InternetIntranet
ESMPRO agents(SNMP)
!
Power supply, Fans failureDisk failureNetwork failure
Notification of any hardware failure & component status change
An alert is sent to the manager
Running
Warning
Error
![Page 8: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/8.jpg)
NEC Confidential8
Event/failure notification & escalation
ESMPROManager
InternetIntranet
Running
Warning
Error
Notification of hardware failure & component status change
!
Send an e-mail to the administrator
Server in error
e-mailwith source of error(s)
![Page 9: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/9.jpg)
NEC Confidential9
Discovering Server Infrastucture
NEC Express5800
Servers
ESMPROManager
InternetIntranet
ESMPRO agents(SNMP)
Detection& organization
Discovery
![Page 10: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/10.jpg)
NEC Confidential10
Server detection and registration in the organization
Choose the method to detect the servers :IP range or network mask
Manual or automatic detection
![Page 11: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/11.jpg)
NEC Confidential11
Server organization (Root = Infrastucture)
Server tree organization
Servers are organized in groups which reflects the
organization
Add group(s)Detect server(s) inside a given group
![Page 12: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/12.jpg)
NEC Confidential12
Monitoring server health status
ESMPROManager
InternetIntranet
2+2 Power Configuration (Hot-Plug)
NEC Express5800Servers
Power supply, FansDisk Network Mother boards………
Hardware componentshealth status
ESMPRO agents(SNMP)
![Page 13: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/13.jpg)
NEC Confidential13
Likely to be the most important to monitor …
ESMPROManager
InternetIntranet
2+2 Power Configuration (Hot-Plug)
NEC Express5800Servers
Power supply, FansDisk Network Mother boards………
More prone to failures ….
Power supply Hard disk drive
Much less problems with Mother board PCI boards
Very critical component Memory Dimms But highly reliable ECC + optional redundancy on top
![Page 14: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/14.jpg)
NEC Confidential14
Server health status
All server components
Main serverinformation
Running
Warning
Error
![Page 15: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/15.jpg)
NEC Confidential15
Deeper dive in
Detailled view of server componentsExpand the tree
![Page 16: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/16.jpg)
NEC Confidential16
Alert viewer
Alerts/Events from the monitored servers
Server(s) name and IP adress of the monitored server(s)
![Page 17: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/17.jpg)
NEC Confidential17
Alert detail (SNMP trap)
Trap error:One of power supply has failed
An e-mail is sentTake the corrective
action
![Page 18: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/18.jpg)
NEC Confidential18
Alert forwarding to an SMTP mailer
Alerts/Events forwarding to SMTP e-mail SMTP
mailer
Adress recipient
![Page 19: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/19.jpg)
NEC Confidential19
Remote Control operations
Functionnal server groups
ESMPROManager
InternetIntranet
Production
Test
Remote control operations Power control Batch Server update (Bios/Firmware) Running time …….
DevelopmentCan be executed at server group or individual server level
![Page 20: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/20.jpg)
NEC Confidential20
Remote control operations
Remoteoperations
![Page 21: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/21.jpg)
NEC Confidential21
Power measurements at server level
Power consumptionfor a given server
Measurementperiod
Power
![Page 22: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/22.jpg)
NEC Confidential22
Power measurements at server group level
Power consumptionfor a group of servers
Cumulated power consomption of all servers in a group
Server Power consumption
![Page 23: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/23.jpg)
NEC Confidential23
Reduce Power consumption (ECO)
Reduce/adjust Powerconsumptionat server level
Different levelsPower reduction by lowering CPU frequency
![Page 24: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/24.jpg)
NEC Confidential24
Choose the groupChoose the server(s) inside the group
Reduce Power consumption (ECO)
![Page 25: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/25.jpg)
NEC Confidential25
Remote Power Control at server/group level
Power controlOS shutdownReset operationsfor a given server or a group of servers
Choose the groupChoose the server(s) inside the group
![Page 26: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/26.jpg)
NEC Confidential26
Remote batch at server/group level
Choose the batch to execute and scedule it
![Page 27: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/27.jpg)
NEC Confidential27
NEC Express5800
Servers
ESMPROManager
InternetIntranet
Manage the software package version
In typical organisation
Difficulties to maintain software package homogeneity Most of the time software packages repository are not updated regularly Or merely do not exist Updates are manual
Requirement for a fully automated solution
Bios 1.21
Bios 1.27
Firm xxx
Firm yyy
Package 1
Package 2
Software control and versionning
is non accurate
![Page 28: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/28.jpg)
NEC Confidential28
NEC Express5800
Servers
ESMPROManager
InternetIntranet
Software update with NEC Express update
Download update modules automatically from a unique central repository (NEC)
BIOS, Firmware, ….
Notify the servers on which updates are required Specify the update required state with special icon
Instruct Starting Remote Update Easy operation from ESMPRO console Multiple update modules to multiple servers
Remotely confirm update completion
Display the completion result with special icon
Central Repository (NEC Web site)
![Page 29: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/29.jpg)
NEC Confidential29
NEC Express Update
Download software packages from this NEC web site
![Page 30: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/30.jpg)
NEC Confidential30
NEC Express Update (package dowload)
Select the software package(s) to installon a given server or a group of server
![Page 31: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/31.jpg)
NEC Confidential31
NEC Express Update (package dowload)
Current software package on a given server
![Page 32: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/32.jpg)
NEC Confidential
32
In-Band server management
ESMPROManager
InternetIntranet
ESMPRO agent(SNMP)
Lan
Redundant Lan(teaming)
In-band management
In case of network failureTransparent failoverNO communication loss
Network connection down notification
Take the corrective action
Lan ports
![Page 33: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/33.jpg)
NEC Confidential
33
Out-of-Band server management
ESMPROManager
InternetIntranet
ESMPRO agent(SNMP)
Lan
Redundant Lan(teaming)
In-band management
Complete network failure
Lan ports
Lan management port
Out-of-Band management
DedicatedLan
Login to NEC Express Scope engine
Need another way for getting access
![Page 34: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/34.jpg)
NEC Confidential
Out-of-Band server management
Login to NEC ExpressScope engine
![Page 35: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/35.jpg)
NEC Confidential35
Out-of-band management with NEC ExpressScope
Expressscope V2:
BMC designed by NEC and compliant with IPMI 2.0 standard.
Out-of-band management mode.
Dedicated management port with web server.
Real time sensor reading
SEL log can be saved into a file.
Remote Power Control.
Server monitoring (T°C, Voltage, Fan speed, Chassis Intrusion, PSU Module, HDD Status, Power
Consumption)
Remote media : including write access on USB key.
Remote KVM as standard : faster, ready to use.
BMC network configuration by SETUP
Alerts by SNMP traps or SMTP mail.
CLI using TELNET / SSH with extended commands.
![Page 36: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/36.jpg)
NEC Confidential36
Expressscope V2
5x SATA(1.5G or 3G bps) (No Repeater)
8.5-10.6GB/s1066/1333MHz Front Side Bus
5.3GB/s
5.3GB/s
5.3GB/s
5.3GB/s
Intel®Xeon™
Processor
Intel®Xeon™
Processor
Intel®Xeon™
Processor
Intel®Xeon™
Processor
Intel® 5000P(Blackford)
Intel® 5000P(Blackford)
Memory12x DDR2-667 FBD(Up to 48GB)ECC, Chipkill, Spare, Mirror2-4Way Interleavedx4 ESI
PCIe(x8)4GB/s
Intel® 6321(ESB2E)
Intel® 6321(ESB2E)
GbE PHY(2ch)(82563EB)
MAC 2ch
1x ATA100
PCIe(x8)PCIe(x8) 4GB/s
PCIe(x8)PCIe(x8) 4GB/s
64bit/133MHz PCI-X (3.3V)
Full height riser
PCI-X133 1.06GB/s
PCIe(x8) 4GB/sPCIe(x8)
Low profile riser
ServerEngines™Server Management Controller2
(Pilot2)
ServerEngines™Server Management Controller2
(Pilot2)
DRAM
2x Serial Ports (1x Rear, 1x internal)
MAC 1ch
BMC
10/100 PHY(1ch)
2x US
B
1x VGA2x PS/2
for BMC & VRAM
PC
Ie(x1)
SPI Flash for BMCVideo
LP
C TPM1.2
BIOSFlash
RMII
CPU2 LGA 771 sockets
4x SATA for for HDD & 1x SATA for tape drive
I/OAT (Standard)2x LAN (for General Use)
1x IPMB
6x USB2.0 (2x Front, 2x Rear, 2x Internal*)
1x LAN(for Management)
![Page 37: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/37.jpg)
NEC Confidential37
Ethernet Management Port
Dedicated management port
IP address policy:
1. Default IP address is 192.168.1.1 (DHCP disabled)2. Can be forced to IP address3. Can be changed to DHCP
Web server policy:
4. Disabled by default5. Can be enabled for HTTP6. Can be enabled for HTTPS
![Page 38: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/38.jpg)
NEC Confidential38
Pre requisites / Log In
OS and Browser: • XP SP2 with IE6/7 or Firefox 2.0• Vista with IE7 or Firefox 2.0• RedHat 4 with Firefox 2.0
JRE:• 1.6 from SUN Microsystems or +
Connection URL:
http://bmc_address:bmc_port
http: better performancehttps: better security
Default account (must be changed for security):
Log in : administratorPassword: <none>
![Page 39: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/39.jpg)
NEC Confidential39
Main Screen: the Control Panel Function
![Page 40: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/40.jpg)
NEC Confidential40
Power Control Menu
These power ON/OFF controls are hardware commands send to BMC
![Page 41: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/41.jpg)
NEC Confidential41
IPMI
MC Information => BMC Firmware versionBackup IPMI => IPMI.DAT fileSystem Environment => Real time sensor reading (T°, V, speed, PSU, Watts…)
![Page 42: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/42.jpg)
NEC Confidential42
Sensor Real Time reading
![Page 43: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/43.jpg)
NEC Confidential43
Remote Devices
![Page 44: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/44.jpg)
NEC Confidential44
Remote Devices Licence
Licence is always bundled with server but still has to be entered into BMC (log out/log in required)Be careful on similar character of license (1 and l, …)
![Page 45: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/45.jpg)
NEC Confidential45
Remote Devices: Remote KVM 1/2
Remote KVM allows to redirect video, keyboard and mouse. Mouse cursor synchronization is auto under Windows (see User Guide for maximum resolution)
![Page 46: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/46.jpg)
NEC Confidential46
Remote Devices: Remote KVM 2/2
In case of key map problem, a virtual keyboard can be used (EN/FR)
![Page 47: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/47.jpg)
NEC Confidential47
Remote Devices: Remote Media
Following device/image can be used for remote media:
• Floppy drive• CD/DVD drive• USB Key (read/write)• ISO image of Floppy/CD/DVD
Device is detected as USB device on server =>
Refer to User Guide for limitation on Remote Media
On 100MB LAN, Remote Media Transfert is = to 1.6x CDROM speed
![Page 48: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/48.jpg)
NEC Confidential48
Configuration (Network/Web/Alerts/CLI)
Network=> LAN settingsWeb Server=> security settings of WebAlert=> SMTP alertsMiscellaneous=> telnet/SSH settings
![Page 49: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/49.jpg)
NEC Confidential49
Configuration (Users)
- Maximum of three users connected simultaneously
- Three users levels: Administrator: view IPMI info, view/change settings, access to remote KVM/Media Operator: view IPMI info, view settings only and no remote KVM/MediaUser: view IPMI info only
![Page 50: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/50.jpg)
NEC Confidential50
CLI by Telnet/SSH
Once CLi enabled, NEC BMC specific commands can be used to control server remotely (See User Guide for details)
![Page 51: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/51.jpg)
NEC Confidential
Integration withother Management framework
HP-Open View (OVO & NNM)Microsoft MOM
Nagios
![Page 52: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/52.jpg)
NEC Confidential© NEC Corporation 2009
Integration with Nagios
NEC Express with ESMPRO Agent
Nagios management server
Net-S
NM
P(snm
ptrapd)
SN
MP
TT
Windows computer with ESMPRO Manager
trap
redirect trap to Nagios
Nagios external command file
Nagios
Nagios periodically check the command file.Output
the result.
![Page 53: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/53.jpg)
NEC Confidential© NEC Corporation 2009
Requirements for Nagios integration
Linux, RHEL Server release 5.2 for this document
Nagios, version 3.0.6 for this document
Net-S NMP, providing trap capture tool “snmptrapd”. Tested version: 5.4.2.1
Associated Perl package Net-SNMP.
SNMP trap translator (aka SNMPTT), that translates SNMP traps to human readable format, and sends the result to Nagios. Tested version: 1.2
NEC ESMPRO Manager, that receives SNMP traps from ESMPRO Agent, then redirects them to the Nagios management server.
![Page 54: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/54.jpg)
NEC Confidential© NEC Corporation 2009
Microsoft Operation Manager 2007
Select the management pack to import
![Page 55: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/55.jpg)
NEC Confidential
Microsoft Operation Manager 2007
![Page 56: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/56.jpg)
NEC Confidential
Microsoft Operation Manager 2007
![Page 57: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/57.jpg)
NEC Confidential© NEC Corporation 2007
Define policy to receive ESMPRO traps in OVO
Select Action > New > SNMP Interceptor menu from OVO.
Press “New…”to define rule.
(see next page)
![Page 58: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/58.jpg)
NEC Confidential© NEC Corporation 2007
Define rule Condition in OVO
Enterprise ID : .1.3.6.1.4.1.119.2.2.4.4.100.2
Generic ID : (6) EnterpriseSpecific
Specific ID : 1 - 3
ESMPRO has 3 kind of traps.
You must define policy rule
respectively.
![Page 59: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/59.jpg)
NEC Confidential© NEC Corporation 2007
Define rule Actions Message in OVO
Severity : select “Normal” for Specific ID 1select “Minor” for Specific ID 2select “Major” for Specific ID 3
Message Text : Use $ notation to refer to trap variables.
Press “OK”until you see the policy editor main
window.(next page)
![Page 60: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/60.jpg)
NEC Confidential© NEC Corporation 2007
Define rule respectively
![Page 61: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/61.jpg)
NEC Confidential© NEC Corporation 2007
ESMPRO traps in the OVO active messages window
File systemalert detectedby ESMPRO
![Page 62: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/62.jpg)
NEC Confidential
Server Management Software ComparisonIn-Band management
© NEC Corporation 2010Page 62
NECESMPRO Ver.5
ComparisonHP
System Insight Manager
Remote Monitoring (HW State, Log, etc.) Yes = Yes
Remote Power Control Yes = Yes
Alert Monitoring Yes = Yes
Retrieve H/W Configuration and OS Information
Yes = Yes
Command Line I/F, Script I/F Yes = Yes
Security (SSL, SSH) Yes = Yes
Web Server Yes = Yes
Task Scheduling Yes = Yes
Scheduled Power Control w/o UPS Yes > No
Automated BIOS/BMC Update,Version Control
Yes (ExpressUpdate) = Yes
Integrated RAID Management Yes > Yes (monitor only)
Virtual LCD Yes > No
Power Consumption Monitoring Yes > Yes (Option License)
Power Capping Control Yes > Yes (Option License)
Directory Service (LDAP) No < Yes
VM Management No (Support with SSC) < Yes (Option License)
![Page 63: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/63.jpg)
NEC Confidential
Management Controller ComparisonOut-of-Band management
© NEC Corporation 2010Page 63
NECEXPRESSSCOPE Engine2
ComparisonHP
iLO2
Remote Monitoring (HW State, Log, etc.) Yes = Yes
Remote Power Control Yes = Yes
Send Alert (SNMP, E-Mail) Yes > Yes (SNMP only)
Retrieve H/W Configuration Yes = Yes
Monitor HDD failure (agent-less) Yes > No
Remote KVM Yes (java-base) < Yes (java-base, ActiveX)
Remote Media Yes = Yes
Security (SSL, SSH) Yes = Yes
Web Server Yes = Yes
Command Line I/F (SMASH CLP) Yes = Yes
Remote F/W update Yes (require tftp server) < Yes
Virtual LCD Yes > No
Power Consumption Monitoring Yes (current value only) < Yes
Power Capping Control Yes = Yes
Directory Service (LDAP) No < Yes
![Page 64: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/64.jpg)
NEC Confidential© NEC Corporation 2009
ESMPRO operation with CLI
64
ESMPRO operations can be also done through command line
C:\>dscli groupPowerOn GroupName(Power ON every servers belonging tothe same group)
Power ON Power ON
Power ON
CLI examples
Power Control (Group DC-ON) - dscli groupPowerOn GroupName - dscli powerOff ServerName
Status Check (Status of server status LED) - dscli getStatusLamp ServerName [sample results] GREEN_ON (LED is green) AMBER_BLINK (Amber blinking)
![Page 65: Esmpro Customer Presentation](https://reader036.vdocuments.us/reader036/viewer/2022081412/545481b2b1af9fc85d8b4b8b/html5/thumbnails/65.jpg)
NEC Confidential© NEC Corporation 2009
Demo for La Caixa De Depositos
65
Express R120a-1with LSI Raid
Teaming
Windows 2008R2Enterprise
ESMPRO Manager 5.x
192.168.2..202
192.168.6.210
Management port
Windows 2008
EMPRO agent 4.52
Universal Raid Utility
Managementstation
Lan Internet
Lan ports
Paris Barcelona