equipment for engineering education & research heat ...solution.com.my/pdf/he158c(a4).pdf ·...
TRANSCRIPT
HEAT EXCHANGER TRAINING
APPARATUSMODEL: HE 158C
SOLTEQ®Equipment for Engineering Education & Research
THIS Heat Exchanger Training Apparatus (Model: HE 158C) is a bench type unit designed to allow
students to get familiarised with different kinds of heat exchangers and to collect the necessary experimental
data for the calculation of heat loss, heat transfer coefficient, log mean temperature difference, etc. Studentwill also be able to study the effect of flow rate on the heat transfer rate. Later, students may use this knowledge for
designing complex industrial heat exchangers.
The HE 158C is supplied with four types of heat
exchangers with two 50-L stainless steel sump tanks
as the source for the hot and cold water circuit. The hot
tank is fitted with a 11.5 kW immersion type heater which
is protected against possible over heating. Each tank
has a centrifugal pump to deliver the hot and cold water
to the heat exchangers. The pumps are somehow
protected from dry-run by level switch installed in each
of the sump tanks. A temperature sensor and
temperature controller are also provided to maintain a
constant desired temperature inside the hot water tank.
The unit is supplied with all necessary instruments to
measure the inlet and outlet temperatures of the hot
and cold water as well as the flow rates of the hot and
cold water and the pressure drops across the heat
exchangers. Piping and fittings are made of stainless
steel materials to prevent rust. The hot water and cold
water circuits are properly insulated to minimize heat
losses or heat gains between the tank and the heat
exchangers.
Rev1.0 17/06/2011
SOLTEQ®
SOLTEQ
Equipment for Engineering Education & Research
EXPERIMENTAL CAPABILITIES
♦ Energy balance determination
♦ Temperature profiles in co-current and counter-
current flow
♦ Log mean temperature difference
♦ Heat transfer coefficient
♦ Flow rate effects on heat transfer rate
♦ Heat loss estimation
♦ Relationship between Nusselt (Nu) and Reynold
(Re) numbers
SPECIFICATIONS:
Bench
Epoxy coated mobile steel bench with lockable swivel
castors.
Shell & Tube Heat Exchanger
Shell : I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Tubes : O.D. = 9.53 mm
I.D. = 7.75 mm
Length = 500 mm
Tube count = 10 (single pass)
Tube pitch = 18 mm (triangle)
Baffle = 8
Baffle cut = 20%
Material = stainless steel 316L
Exchange area : 0.15 m2 (approx.)
Concentric (Double Pipe) Heat Exchanger
Shell : I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Tube : O.D. = 33.4 mm
I.D. = 26.64 mm
Length = 500 mm
Material = stainless steel 316L
Exchange area : 0.05 m2 (approx.)
Spiral Heat Exchanger
Shell : I.D. = 85 mm
Length = 500 mm
Material = borosilicate glass
Coil : O.D. = 9.53 mm
I.D. = 7.05 mm
Length = 5 m
Material = stainless steel 316L
Exchange area : 0.15 m2 (approx.)
Plate Heat Exchanger
No. of plates : 6
Plate material : stainless steel 316L
Connections : 3/4” NPT
Dimensions : 4.9” x 12.2” x 1.7” (W x L x D)
Exchange area : 0.18 m2
Sump Tanks
Capacity : 50 L
Material : Stainless steel
Ports : Inlet/outlet/drain
Heater : 11.5 kW for hot tank with temperature
control
Pumps
Type : Centrifugal, stainless steel
Capacity : 0 to 50 LPM
Head : 10 m
Electrical : 240VAC/1-phase/50 Hz
Instrumentations
Flow meters : 0 to 10 LPM (cold water)
0 to 10 LPM (hot water)
Temperatures : 0 to 100 °C
Manometer : 0 to 50 cm of water
Temperature sensor and controller
Control Panel
♦ Temperature controller for heater input to maintain
the hot water temperature and prevent over heating.
♦ On/off buttons for pumps and heater.
OPTIONAL ITEMS
- EI
DIGITAL INSTRUMENTATIONS
i) 8 units of digital indicators
ii) 4 units of temperature sensors c/w transmitter
iii) 2 units of electronic flow meters
iv) 2 units of differential pressure transmitters
Rev1.0 17/06/2011
SOLTEQ
TYPICAL EXPERIMENT RESULTS
Shell & Tube Heat Exchanger with Variable Hot Water Flow Rate
0
200
400
600
800
1000
1200
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000
Tube side (hot water) Reynolds number
Ov
era
ll h
ea
t tr
an
sfe
r c
oe
ff.
(W/m
2.K
)
Cold water at 20 LPM Cold water at 15 LPM Cold water at 10 LPM
Cold water at 20 LPM
Cold water at 15 LPM
Cold water at 10 LPM
-DAS
SOLDAS DATA ACQUISITION SYSTEM
i) A PC with latest Pentium Processor
ii) An electronic signal conditioning system
iii) Stand alone data acquisition modules
iv) Windows based data acquisition software
♦ Data Logging
♦ Signal Analysis
♦ Process Control
♦ Real-Time Display
♦ Tabulated Results
♦ Graph of Experimental Results
- CAL
SOLCAL COMPUTER AIDED LEARNING
SOFTWARE
i) Interactive multimedia features
ii) Graphical simulation
iii) Experiment results samples
iv) Full experiment manuals
REQUIREMENTS
Electrical supply: 415VAC/3-phase/50Hz
Water supply
Drainage points
OVERALL DIMENSIONS
Height : 1.50 m
Width : 1.52 m
Depth : 0.91 m
MANUAL
The unit is supplied with Operating and Experiment
Manuals in English giving full descriptions of the unit,
summary of theory, experimental procedures and
typical experimental results.
SOLTEQ®Equipment for Engineering Education & Research
Rev1.0 17/06/2011
Our range of teaching equipment can be complemented with our
SOLDAS and SOLCAL software.
SOFTWARE & E - LEARNING
SOLDAS - Supervisory Control & Data Acquisition
- Data Logging
- Signal Analysis
- Process Control
- Real-Time Display
- Tabulated Results
- Graph of Experimental Results
SOLCAL - Computer Aided Learning
- Multimedia Features
- Interactive
- Graphic Simulation
- Experiment Result Samples
- Full Experiment Manuals
SOLTEQ®
Contact us for a catalog CD
SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)
Sales Office :
No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000Fax. No. : +(603) 80755784
R&D Office :
G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023
Email : [email protected] site : http//www.solution.com.my/
AGENT:
Equipment for Engineering Education & Research
BUATAN MALAYSIAMSC- Status
Company
®
®
Rev1.0 17/06/2011