enterprise offline viewer v1.2

9
Enterprise Offline Viewer v1.2.0 README Enterprise Configuration Offline Viewer (EOV) is a useful tools design for Hitachi Enterprise Storage Subsystem that can view configuration (offline), extract all data to HTML/CSV/Excel, build raidcom script, horcm & etc. CONTACT If you have problems, question, suggestion & request key to use this application, please mail to me: [email protected]. If you request Registration Key, please send your HardwareID (Help>HardwareID) inside email body. CONTENTS I. General notice II. Minimum system requirements III. How to use IV. Application Hotkeys V. Application Menu structure & specific notice I. General notice - Only support VSP, VSP Gx000, VSP G/F x00, HUSVM, USPV & USPVM. - All capacity base is from block size then converted to [MB/GB/TB/PB] using base Two (default) calculation, please modify settings if you want custom value. - For detail update & features please open CHANGE.LOG or click “Help>Change Log” II. Minimum system requirements Enterprise Configuration Offline Viewer (EOV) already test & running well on Windows XP, 7, 8 & 10 environment. For windows 8 or 10, you must do below instructions before use Enterprise Configuration Offline Viewer (EOV): - Open Windows Command Prompt by right click the icon then “Run as Administrator”. - Goto EOV directory - Execute this command: regsvr32.exe MSCOMCTL.OCX III. How to use Before you use this application, you must have valid configuration (*.CSV) that already dump/create from Hitachi Enterprise Storage Subsystem. - Get CSV configuration files This step explaining how to Get CSV configuration files from storage subsystem.

Upload: others

Post on 04-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Enterprise Offline Viewer v1.2

Enterprise Offline Viewer v1.2.0

README

Enterprise Configuration Offline Viewer (EOV) is a useful tools design for Hitachi

Enterprise Storage Subsystem that can view configuration (offline), extract all data

to HTML/CSV/Excel, build raidcom script, horcm & etc.

CONTACT

If you have problems, question, suggestion & request key to use this application,

please mail to me: [email protected].

If you request Registration Key, please send your HardwareID (Help>HardwareID)

inside email body.

CONTENTS

I. General notice

II. Minimum system requirements III. How to use IV. Application Hotkeys V. Application Menu structure & specific notice

I. General notice

- Only support VSP, VSP Gx000, VSP G/F x00, HUSVM, USPV & USPVM.

- All capacity base is from block size then converted to [MB/GB/TB/PB] using base

Two (default) calculation, please modify settings if you want custom value.

- For detail update & features please open CHANGE.LOG or click “Help>Change Log”

II. Minimum system requirements Enterprise Configuration Offline Viewer (EOV) already test & running well on

Windows XP, 7, 8 & 10 environment.

For windows 8 or 10, you must do below instructions before use Enterprise

Configuration Offline Viewer (EOV):

- Open Windows Command Prompt by right click the icon then “Run as Administrator”.

- Goto EOV directory

- Execute this command:

regsvr32.exe MSCOMCTL.OCX

III. How to use Before you use this application, you must have valid configuration (*.CSV) that

already dump/create from Hitachi Enterprise Storage Subsystem.

- Get CSV configuration files

This step explaining how to Get CSV configuration files from storage subsystem.

Page 2: Enterprise Offline Viewer v1.2

• EOV

Goto File>Download Report to download & extract configuration report

Please take a note, port 5543 must be open.

• Storage Navigator

Below step only work for On VSP, VSP G1000, VSP Gx00 & HUSVM storage, because

we can directly get CSV configuration files via Storage Navigator.

Page 3: Enterprise Offline Viewer v1.2

• Hitrack

For HDS internal, we can download CSV configuration files directly via

hitrack.hds.com

• SVP

Below step is normal procedure to get & create CSV configuration files:

Get DKC200 configuration files

o RDP to SVP

o Change mode into “Modify Mode” on SVP application

o Click Install

o Click “Copy Config Files”

o Click “Create Configuration Backup”

Page 4: Enterprise Offline Viewer v1.2

Convert DKC200 configuration files to CSV configuration files using Hitachi

Configuration Print Out application:

o Extract svp_conf.tgz using WinRAR/WinZIP/7ZIP

o Open “Offline Tools” (Configuration Print Out)

Notes:

Install “Offline Tools” from “Document & Programs DVD”, after install. On start menu this folder

will created:

- VSP : RAID700 Offline Tool

- HUSVM: Offline Tool V73

- USPV/USPVM: RAID600 Offline Tool

o Click Create

o Check Output Directory (many *.csv files will be created on there)

- Start using Enterprise Configuration Offline Viewer (EOV)

Open EOV.exe, then goto File>Open or press Ctrl+O

Open directory that contains *.csv or open from Repository (Ctrl+R or File>Open

Repository)

Page 5: Enterprise Offline Viewer v1.2
Page 6: Enterprise Offline Viewer v1.2

Open File>Settings if you want customize Enterprise Configuration Offline

Viewer (EOV)

Sample screenshot (Table View) Pool configuration from Enterprise Configuration

Offline Viewer (EOV).

Page 7: Enterprise Offline Viewer v1.2

Sample screenshot (Detail View) Pool configuration from Enterprise

Configuration Offline Viewer (EOV).

Sample screenshot Custom Report from Enterprise Configuration Offline Viewer

(EOV).

Page 8: Enterprise Offline Viewer v1.2

IV. Application Hotkeys

- F5

• Table View: Refresh all data

• Detail View: Refresh selected data

- F12: Display “Setting Dialog”

- Ctrl + O: Display “Open Dialog”

- Ctrl + F: Display “Filter Dialog”

- Ctrl + T: Toggle OnTop (On/Off)

- Ctrl + X: Exit

- Ctrl + C: Copy selected record when focus on ListView Table or textbox

- Ctrl + E: Copy selected record when focus on ListView then export to Excel

- Ctrl + A: Select All record when focus on ListView Table or textbox

- Shift + A: UnSelect All record when focus on ListView Table

- Alt + C: Copy all data on “Detail View” to clipboard

- Alt + E: Export all data on “Detail View” to Excel

- Esc

When at:

- Table View: exit form

- Filter View: go back to Table View

- Detail View: go back to Table View

- Navigation on Detail View:

o ctrl + Arrow Down/Right: Next record

o ctrl + Arrow Up/Left: Previous record

- Ctrl + F12: Show Temporary Cache

V. Application Menu structure & specific notice

Enterprise Configuration Offline Viewer (EOV) Menu Structure

- File

• Open

• Open Repository

• Download Configuration Report

• History

• On Top

• Tools

➢ Generate Report

➢ Custom Report

➢ Raidcom

➢ Create HORCM

➢ Text Tools

• Settings

• Exit

- Storage Systems

• Basic Configuration Information

• Component

➢ MP Units*

➢ CLPR *

➢ CHA*

➢ DKA

➢ HDU

➢ Drives

• Parity Groups

➢ Internal*

➢ External*

• Logical Devices*

• Pools*

Page 9: Enterprise Offline Viewer v1.2

• Port/Host Groups

➢ Host Groups*

➢ Hosts

➢ Ports

• External Storages

➢ External Volume

➢ External Paths

• License Key

• Window

➢ Tile Horizontally

➢ Tile Vertically

➢ Cascade

➢ Close All

• Help

➢ Change LOG

➢ Hardware ID

➢ Help

Enterprise Configuration Offline Viewer (EOV) specific notice

❖ You can Copy all contents on every form module then paste to excel or any

text editor. (Pls goto File>Settings if you want to change CSV delimiter &

others settings.

❖ All menu with suffix *, can view more detail by Double clicking on every

table if you want to goto specific module/form.

❖ Goto “Storage Systems> Basic Configuration Information” to find more

configuration information inside CSV files.

This form module similar with “RAIDxxx Offline Tools”