2
8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected] ENHANCED STRIP CHANNEL T8 FEATURES • Instant restrike • Three optics design available • Uplight option • Unibody aluminum construction • Higher color rendering • Dimming, occupancy sensor and emergency options available • Improved lumen maintenance • Extended lamp & ballast life • 480 Volt option ORDER LOGIC PROJECT INFORMATION Project Name Catalog # Type Date CUT SHEET: ENHANCED STRIP CHANNEL T8 APPLICATION • Linear fluorescent T8 High Bay or Low bay lighting in stack aisles, open area warehousing and task applications. • Multiple lamp and beam-spread configurations. • Aluminum housing designed for maximum efficiency and extended component life. • General or task applications where channel lighting is desired. • Suitable for pendant, surface, suspended or continuous row installation. CONSTRUCTION • Uni-body specular aluminum construction .032” thick. • Lampholder brackets match housing material. • Brackets secured to housing with machine screws adding strength and rigidity. • Ballast chamber vented for heat removal increasing ballast life. • Ballast covers match housing material, secured in place with quarter turn fasteners. • Uplight slot option available for ceiling illumination. ELECTRICAL • Quality name brand Class P, HPF electronic ballasts. • Lampholders are injection molded rotating camlock design. • Occupancy sensors and emergency options. • U.L. listed damp location. 4 - 4 ft. 8 - 8 ft. ESC 32 01 02 03 04 06 Length # Lamps M - Enhanced alum. W - White alum. Reflector Material 6 - 6 ft. 8 - 8 ft. 1 - 12 ft. X - None Cord Length S - Spread N - Normal T - Task Optics S - Slots X - None Up-Light G - Adjustable cable system (2) Y - Y hangers (2) X - None Mounting 1 - Aisle, multi-volt 120 - 277 2 - Open area, multi-volt 120 - 277 3 - Aisle 480 line voltage 4 - Open area 480 line voltage X - None Occupancy Sensors 3 - (1) F32, 90 min. 8 - (1) or (2) F32, 90 min. X - None Emergency Battery Backup F - Fuse L - Lamps installed W - Whip Special Options 120 - 120v Normal BF 277 - 277v Normal BF UIN - Multi-volt 120-277 Instant start, Normal BF UIH - Multi-volt 120-277 Instant start, High BF Ballast A - 120v 15 amp straight-blade B - 277v 20 amp twistlock C - 480v 20 amp twistlock D - 277v 15 amp twistlock F - 120v 15 amp twistlock X - None Nema Plug W1 - Wire guard 11ga. XX - None Shielding 001 - (1) 1 lamp 002 - (1) 2 lamp 003 - (1) 3 lamp 022 - (2) 2 lamp 004 - (1) 4 lamp 033 - (2) 3 lamp 024 - (1) 2 lamp, (1) 4 lamp 222 - (3) 2 lamp Ballast Configuration Consult factory for dimming options. Refer to options terminology matrix for additional options.

Upload: crystal-pettibone

Post on 27-Mar-2016

219 views

Category:

Documents


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Enhanced Strip Channel T8

8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

ENHANCED STRIP CHANNEL T8

fEATuRES

• Instantrestrike

• Threeopticsdesignavailable

• Uplightoption

• Unibodyaluminumconstruction

• Highercolorrendering

• Dimming,occupancysensorand emergencyoptionsavailable

• Improvedlumenmaintenance

• Extendedlamp&ballastlife

• 480Voltoption

oRDER LogIC

Project InformatIon

Project Name

Catalog #

Type

Date

CuT SHEET: ENHANCED STRIP CHANNEL T8

APPLICATIoN • LinearfluorescentT8HighBayorLowbay lightinginstackaisles,openareawarehousing andtaskapplications.

• Multiplelampandbeam-spreadconfigurations.

• Aluminumhousingdesignedformaximum efficiencyandextendedcomponentlife.

• Generalortaskapplicationswherechannel lightingisdesired.

• Suitableforpendant,surface,suspendedor continuousrowinstallation.

CoNSTRuCTIoN • Uni-bodyspecularaluminumconstruction .032”thick.

• Lampholderbracketsmatchhousing material.

• Bracketssecuredtohousingwithmachine screwsaddingstrengthandrigidity.

• Ballastchamberventedforheatremoval increasingballastlife.

• Ballastcoversmatchhousingmaterial, securedinplacewithquarterturnfasteners.

• Uplightslotoptionavailableforceiling illumination.

ELECTRICAL • QualitynamebrandClassP,HPFelectronic ballasts.

• Lampholdersareinjectionmoldedrotating camlockdesign.

• Occupancysensorsandemergencyoptions.

• U.L.listeddamplocation.

4 - 4 ft.8 - 8 ft.

ESC 32

0102030406

Length # Lamps

M - Enhanced alum.W - White alum.

Reflector Material

6 - 6 ft.8 - 8 ft.1 - 12 ft.X - None

Cord Length

S - SpreadN - NormalT - Task

Optics

S - SlotsX - None

Up-Light

G - Adjustable cable system (2)Y - Y hangers (2)X - None

Mounting

1 - Aisle, multi-volt 120 - 2772 - Open area, multi-volt 120 - 2773 - Aisle 480 line voltage4 - Open area 480 line voltageX - None

Occupancy Sensors

3 - (1) F32, 90 min.8 - (1) or (2) F32, 90 min.X - None

Emergency Battery Backup

F - FuseL - Lamps installedW - Whip

Special Options

120 - 120v Normal BF277 - 277v Normal BFUIN - Multi-volt 120-277Instant start, Normal BFUIH - Multi-volt 120-277Instant start, High BF

Ballast

A - 120v 15 amp straight-bladeB - 277v 20 amp twistlockC - 480v 20 amp twistlockD - 277v 15 amp twistlockF - 120v 15 amp twistlockX - None

Nema Plug

W1 - Wire guard 11ga.XX - None

Shielding001 - (1) 1 lamp002 - (1) 2 lamp003 - (1) 3 lamp022 - (2) 2 lamp004 - (1) 4 lamp033 - (2) 3 lamp024 - (1) 2 lamp, (1) 4 lamp222 - (3) 2 lamp

Ballast Configuration

Consultfactoryfordimmingoptions.Refertooptionsterminologymatrixforadditionaloptions.

Page 2: Enhanced Strip Channel T8

8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

xTrALiGHT.COM

ENHANCED STRIP CHANNEL T8

PHoTomETRIC DATA

DImENSIoNAL DATA

CuT SHEET: ENHANCED STRIP CHANNEL T8

48”

96”

6”

4”

7/8” K.O. 3/8” mounting hole (2)

2” K.O.

3 1/2” 3 1/2” 3 1/4”

3205

2404

1803

801

7015

5261

3507

1754

2268

1701

1134

567

3887

2915

1943

972

6101

4575

3050

1525

5673

4255

2836

1418

1910

1432

955

477

3065

2299

1533

766

4531

3399

2266

1133

eSc-8-232 Specular task Beam• Total Rated Lamp Lumens 5800 (2 lamps)• Total Luminaire Efficiency 96.3 %• CIE Type Direct• Spacing Criteria Along 1.2• Spacing Criteria Across 0.5

eSc-8-232 Specular normal Beam• Total Rated Lamp Lumens 5800 (2 lamps)• Total Luminaire Efficiency 95.6 %• CIE Type Direct• Spacing Criteria Along 1.2• Spacing Criteria Across 1.5

eSc-8-232 Specular Spread Beam• Total Rated Lamp Lumens 5800 (2 lamps)• Total Luminaire Efficiency 95.3 %• CIE Type Direct• Spacing Criteria Along 1.4• Spacing Criteria Across 2.5

eSc-8-432 Specular task Beam• Total Rated Lamp Lumens 11600 (4 lamps)• Total Luminaire Efficiency 95.3 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 0.7

eSc-8-432 Specular normal Beam• Total Rated Lamp Lumens 11600 (4 lamps)• Total Luminaire Efficiency 93.3 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 1.6

eSc-8-432 Specular Spread Beam• Total Rated Lamp Lumens 11600 (4 lamps)• Total Luminaire Efficiency 94.4 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 2.0

eSc-8-632 Specular task Beam• Total Rated Lamp Lumens 17400 (6 lamps)• Total Luminaire Efficiency 92.7 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 0.9

eSc-8-632 Specular normal Beam• Total Rated Lamp Lumens 17400 (6 lamps)• Total Luminaire Efficiency 90.7 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 1.6

eSc-8-632 Specular Spread Beam• Total Rated Lamp Lumens 17400 (6 lamps)• Total Luminaire Efficiency 92.2 %• CIE Type Direct• Spacing Criteria Along 1.3• Spacing Criteria Across 2.1