The common problems of feeder cable installation
The type of problem The standards of Quality Check method
The feeder cable connector
1.The connector is not screwed well2.The VSWR is high
1The cut surface remain flat, and on the top wave of screwthread
2
It is necessary that rasp flat to the surface of kerf Feeder cableuse the rasp.
3The connector of feeder cable is made in a standard waywithout any loose connection.
Self-check
The instrument of
VSWR
The technique of connector
1.no anti-water adhesive tape
2.anti-water adhesive tape wraped no
well
3.The strap fastened no well
4.The strap have no remaining
5.The strap type choice fault
1Waterproof and sealed measures for all outdoor jumpers andfeeder cables should be correctly adopted according to
specifications.
2The labels of communication cables, feeder cables and jumpershould be stuck and tied according to specifications. The labels
should be arranged in an orderly way with same direction.
3It is necessary that black strap outdoor and white indoor.
Visual
Measurement
The distribution of feeder cable
1.no according to design
2.The radius of feeder cable bend is
small
3..no anti-water bend in front of the
feeder cable window
4.The feeder cable crossed no tidily,no fastened.
5.no feeder cable ladder
6.no ground earth
1The installation position of feeder should be accorded with thedesign document.;
2The feeder cables can not cross after distributed. In the roomthey should be neat and straight with same bend;
3The space between feeder clamps should be even and theirdirection should be same after installed. They should also be
fixed firmly without any loose connection;
4The antenna jumper and the feeder cable before the feeder
winder must have waterproof bends.5The feeder grounding clip is directly fixed on the steel sheet ofthe tower perfectly. The installation of this clip must accord with
the standard requirement. The antirust, anticorrosive and
waterproof measures are adopted for the grounding clip and
reliable connection.
Visual
Measurement
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
3/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 3
. The connector of feeder cable is made in a standard way without
any loose connection.
Making the connector of feeder cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
4/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 4
Problem:
The connector
has no
waterproof
mastic cement
The technique of connectorAnti-water is not sealed well
Suggestion:Use the
water-proof
mastic
cementand
PVC tape
. Waterproof and sealed measures for all outdoor jumpers and feeder
cables should be correctly adopted according to specifications.
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
5/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 5
Suggestion:
It is necessary
that the water-
proof adhesive
tape wrap the
connector and
waterproofmastic cement
Problem:Deficient
tape,deficient
cement,wate
r-proof seal
will be
damaged byweather.
The technique of connectorAnti-water is not sealed well
. The feeder cables should not have obvious bending and twisting
and bare copper appearance.
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
6/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 6
The technique of connectorNo fasten strap
Problem:
No cable
strap is
not
regular
Suggestion:
Use the
cable strap
to fasten
. The feeder cable should be fixed firmly with strapdont leave tooshort when strap is sniped.
E i i Q lit C P bl 4 F d C bl
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
7/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 7
The technique of connectorNo strap redundant
Problem:If no
redundant
, It is easy
to deprive
Suggestion:
New strap
with a small
redundant.
. The feeder cable should be fixed firmly with strapdont leave tooshort when strap is sniped.
E i i Q lit C P bl 4 F d C bl
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
8/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 8
The technique of connectorNot correct cable strap
Problem:It is not
correct
that
indoor
strap
used tooutdoor
. The feeder cable should be fixed firmly with black strap outdoorBut it should be fixed firmly with white strap indoor
Engineering Quality Common Problems 4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
9/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 9
suggestion:Arrange 3
layers feeder
cable
In a clip.
Problem:It is not
correct
that
separate
layers.
Feeder cable distribution
. The feeder cable is fixed in the clip and make the 3 layers accordingto design
Engineering Quality Common Problems 4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
10/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 10
. The minimum bending radius of a feeder cable should not be lessthan 20 times of its diameter.
Feeder cable distributionBending
Engineering Quality Common Problems 4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
11/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 11
. The feeder cable before the feeder cable window must have waterproof
bends.
Feeder cable distributionAnti-water bending
Engineering Quality Common Problems 4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
12/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Engineering Quality Common Problems4 Feeder Cable
Page 12
Suggestion:
Use the clipto fix
Feeder
cable on the
tower.
Problem:
The feedercable is not
fixed of clip
Feeder cable distributionFix or not
. The space between feeder cable clamps should be even and their directionshould be same after installed. They should also be fixed firmly without any
loose connection.
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
13/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
g g Q y
Page 13
. When the feeder cables is bent onthe top of a building and then
extended downward along the
wall, the protective means should
be used for the parts of contact
with the wall corner. When the
feeder cable enter to room alongthe roof, the feeder cable clips
should be used to fix the feeder
cables.
Feeder cable distributionFixed well in front of window
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
14/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
g g y
Page 14
. The grounding cable is outputed from the bottom of anti-water
Feeder cable distributionGrounding cable
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
15/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15
. Waterproof and sealed measures for all outdoor jumpers and feeder
cable should be correctly adopted according to specifications.. The feeder cables should not have obvious bending and twisting and
bare copper appearance.
Feeder cable distributionDon`t bare the copper
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
16/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16
Suggestion:
Design and
install
ladder, fix
feeder
cable on the
ladder.
Problem:
If noladder, It`s
easy that
break off or
damage
the feeder
cable.
Feeder cable distributionLadder
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
17/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17
. The feeder cable should be earthed at three points at least between the top of tower and the equipment room (within one meter away
from the platform on the top of tower, within one meter between the tower body and the outdoor cabling ladder, and within one meter
between the feeder cable and the feeder window). The feeder cable is tied firmly at the grounding points and has perfect waterproof
treatments.
Problem:
There is no
grounding
bar and no
grounding
earth.
Feeder cable is not grounding earth
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
18/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18
Appendix1The checklist of feeder cable
Problem type Check item
A The connector of feeder cable is made in a standard way without any loose connection.
A Waterproof and sealed measures for all outdoor jumpers and feeder cables should becorrectly adopted according to specifications.A The redundant part of a grounding cable or power cable or feeder should be cut and cannotbe coilled.A The feeder cables should not have obvious bending and twisting and bare copperappearance.B The minimum bending radius of a feeder cable should not be less than 20 times of its
diameter.
BWhen the feeder cable is bent on the top of a building and then extended downward along
the wall, the protective means should be used for the parts of contact with the wall corner.
When the feeder cable enter to room along the roof, the feeder clamps should be used to fix
the feeder cable.
BThe feeder cable should be earthed at three points at least between the top of tower and the
equipment room (within one meter away from the platform on the top of tower, within one
meter between the tower body and the outdoor cabling ladder, and within one meter between
the feeder cable and the feeder window). The feeder cable is tied firmly at the groundingpoints and has perfect waterproof treatments.
B The antenna jumper and the feeder cable before the feeder winder must have waterproofbends.
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
19/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19
Problem type Check item
B The space between feeder clamps should be even and their direction should be same afterinstalled. They should also be fixed firmly without any loose connection;
BWhen a feeder window is installed on the top of building to lead the feeder cable into the
room, it must be sealed well. The antenna jumper and the feeder cable before the feeder
winder must have waterproof bends.
B The feeder cables can not cross after distributed. In the room they should be neat andstraight with same bend;
B The grounding cable of feeder clips should extend from up to down. The angle between thegrounding cable and the feeder cable should not be more than 15 degrees.
BThe feeder grounding clip is directly fixed on the steel sheet of the tower perfectly. The
installation of this clip must accord with the standard requirement. The antirust, anticorrosive
and waterproof measures are adopted for the grounding clip and reliable connection.
BThe labels of communication cables, feeder cables and jumper should be stuck and tied
according to specifications. The labels should be arranged in an orderly way with same
direction.
Appendix2The checklist of feeder cable
Engineering Quality Common Problems4 Feeder Cable
-
7/28/2019 Engineering Quality Common Problem Series (4) - Feeder Cable
20/20
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20
Problem type Check item
B The angle When the tower is more than 60 meters, add a grounding clip to the feeder in themiddle of the tower
BIf the length of feeder cable from the tower to the room on the roof (or cabling ladder) is
more than 20 meters, a lightning-proof protection grounding clip should be added on the
roof (or cabling rack).
CWhen the front of cabinet is parallel to the feeder cable inside the room or the back of
cabinet faces it, a sector is in line and the order of each line should be same. When the front
of cabinet is vertical to the feeder cable inside the room, a sector is in row and the order ofeach row should be same.
Appendix3The checklist of feeder cable