engineered for flexibility and performance · general-catalogue engineered for flexibility and...

112
Air to water heat pumps Air cooled chillers Free cooling Water cooled chillers Fan Coils 2010/ 2011 GENERAL- CATALOGUE Engineered for flexibility and performance

Upload: others

Post on 23-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

Air to water heat pumps

Air cooled chillers

Free cooling

Water cooled chillers

Fan Coils

2010/ 2011

GENERAL- CATALOGUE

Engineered for flexibility and performance

Page 2: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

COO

LED

CH

ILLE

RS

FREE

CO

OLI

NG

FAN

CO

ILS

AIR

TO W

ATER

HEA

T PU

MPS

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

99592715

WAT

ER C

OO

LED

CH

ILLE

RS

67

Page 3: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

Symbols

Function

Cooling

Heating

Cooling / Heating

2 Pipe System

4 Pipe System

Exchanger (Evaporator)

PlateHeat Exchanger

Shell & TubeHeat Exchanger

FloodedHeat Exchanger

Refrigerant/ Fluid

R-134a

R-407C

R-410A

WaterW

Installation

Wall

Floor- / CeilingInstallation

Ceiling Concealed Installation

DuctedInstallation

Floor standing Installation

IndoorInstallation

OutdoorInstallation

W

Inverter

Verdichter

RotataryCompressor

ScrollCompressor

Single ScrewCompressor

CentrifugalCompressor

InverterTechnology

Fan

Axial Fan

OIL FREE

MagnitudeCentrifugalCompressor

free cooling

Free Cooling

Page 4: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 5: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

APPLIED SYSTEM

Page 6: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

ENGINEEREDFOR FLEXIBILITYAND PERFORMANCE

4

McQuay International is a global leader in system solutions for air conditioning, heating, ventilating and refrigeration.

Our engineered flexibility allows us meet our customers’ expectations for quality, reliability, low installation, operating and maintenance costs, high energy efficiency, quite operation and comfort.

Page 7: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A HISTORYOF LEADERSHIP

5

Combining the best ideas in technology and industry leading innovations has allowed us to provide systems and solutions that continue to meet the changing requirements of our customers.

McQuay companies and brands date back to 1785 when J&E Hall began doing business in

the United Kingdom. In the United States, we pioneered the manufacture of the steam

engine in 1872 and built our first radiator in 1933. The strengths of well-known companies

such as Remington, Singer, Herman Nelson Company, American Air Filter and Westinghouse

have kept McQuay at the forefront of changes in the air conditioning, heating, ventilating

and refrigeration industry, leading the industry in environmental and system solutions.

e

s

h

a

Page 8: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

LEADING THE WAYWITH INNOVATIVE SOLUTIONS

6

McQuay has always been at the forefront of creating new technology to meet the changing requirements of our customers.

McQuay’s products and system solutions are as

diverse as our customers' requirements for quiet

operation, improved indoor air quality, energy

efficiency, lower installation, operating and

maintenance costs and reliability.

We design and manufacture McQuay products to

create a comfortable environment in every climate.

Page 9: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

COMMITMENTTO THEENVIRONMENT

7

McQuay has led the way in providing high-performance, cost-effective solutions that preserve and protect our natural environment in addition to providing maximum comfort.

It starts with efficiency. Our products make the most of our

planet’s precious resources using advancements that

minimize energy consumption. McQuay has also led the

way in using non-ozone depleting refrigerants and

developing quiet operating equipment.

Page 10: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

QUALITYASSURANCE

8

ISO 9001:2000 is an international reference for quality management certification. Conformity of products and services to ISO 9001:9000 provides assurance about their quality, safety and reliability.

EUROVENT certifies that equipments perform as intended. Annual tests are carried out in an indipendent laboratory on randomly chosen production units.The certification is granted only if the performance matches the submitted data.

CE conformity guarantees that systems comply to safety requirements according to European Standards.

Page 11: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

GLOBAL SUPPORTLOCAL PRESENCE

9

McQuay is uniquely positioned to make sure our products and services are always within our customers’ reach.Offices on six continents in more than 75 countries are

augmented by thousands of local sales and after-sale

service and parts organizations, alliances and joint ventures

with some of the largest companies in the industry to

support our products.

McQuay has the capacity to fulfill manufacturing

commitments around the world.

Our thirteen manufacturing plants with more than 200,000

square meters à6 million square feet) of manufacturing

space bring together the most innovative manufacturing

practices on three continents.

Kuala Lampur

Production Facilities

Suzhou

Shenzhen

Wuhan

Cecchina, RomaMilano

Cramlington

StauntonTlalnepantla

AuburnOwatonna

Minneapolis

Faribault aircool, Munich

McQuay distributor - Germany

Page 12: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

SOME PRESTIGIOUSINSTALLATION

10

Melbourne Queen Vistoria Village - AustraliaMacarthur SQ Shopping Center - AustraliaUniversity of Technology, Sydney - AustraliaAirport Garden - BelgiumGlaxosmithklnine - BelgiumVolvo Gent - BelgiumJanssen Pharmaceutica - BelgiumTobbaco Factory Sarajevo - Bosnia and HerzegovinaPliva New Research Institute - CroatiaAudi Ingolstadt - GermanyBASF Hannover - GermanyBMW München - GermanyGiesecke & Devrient München - GermanySiemens München - GermanyUniversität Augsburg - GermanyOrganisation of Pireaus Port - GreeceOlympia Riviera Resort - GreeceAthens Imperial Hotel - GreeceAthens Airport El. Venizelos - GreeceCARS Larisa - GreeceAirport of Heraclio, Creta Island - GreeceT. S. T. & Empire Centre - Hong KongChina Ferry Terminal - Hong Kong MTRC Stations - Hong KongHong Kong Central Library - Hong KongFOXCONN Mobile Telephone Parts Manufacturing Co. - HungaryHotel Intercontinental - HungaryFour Seasons Gresham Palace Budapest - HungaryRadicifilm Tiszaújváros - HungaryProcter&Gamble Csömör - HungaryNatsteel - Solectron Manufacturing Co. - HungaryFerihegy Budapest AIRPORT - HungaryEkalokasari Plaza Bogor - IndonesiaAeroporto di Fiumicino Roma - ItalyAeroporto Malpensa 2000 Varese - ItalyAuditorium Città del Vaticano - Italy Auditorium di Roma - Italy

Ferrari Maranello - Italy Ferrero Alba - Italy Fiat Auto - Italy Fincantieri Genova - Italy Galleria d’Arte Moderna Roma - Italy Galleria degli Uffizi Firenze - Italy New Milan-Based Exhibition System - Italy Pirelli Bicocca Milano - Italy Procter & Gamble Roma - Italy TSS Albatros - Monaco Princip. Tetra Pak - NederlandErasmus - NederlandGlaxoSmithKline - Poznan - PolandVolkswagen - Poznan - PolandFerrero - Belsk Duzy - PolandAsian Games Village - QatarRamstore Moscow - RussiaRokadovskaja mineral water bottlers - RussiaMercator Multikino, Celje - SloveniaHIT Casino Perla, Nova Gorica - SloveniaCASA AIRBUS - SpainHospital de Valdecilla - SpainBilbao Exhibition Centre - SpainCentral Nuclear Asco - SpainEl Corte Inglés Sanchinarro - SpainInduyco - SpainFilature Mahdia - TunisieLares Hotel - TurkeyKonya Hilton Hotel - TurkeyFord Otosan - TurkeyAnadolu Health Center - TurkeyBurg Al Arab Dubai - U.A.E.Emirates Tower Dubai - U.A.E.Pfizer, Kent - United KingdomMinistry of Defence, London - United KingdomIBM (UK), Warwick - United KingdomTAG McLaren F1, Woking - United KingdomBelgrade Arena - Yugoslavia

Page 13: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL
Page 14: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

APPLIED SYSTEMPRODUCT RANGE

Page 15: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

INDEX

13

IND

EX

AIR TO WATER HEAT PUMPS

Minichiller R-410A

Minichiller Inv. R-410A

Minichiller R-407C

McSmart

McEnergy HPI “Extension”

16

18

20

22

24

AIR COOLED CHILLERS

McSmart

McEnergy Mono

McEnergy Evolution

McEnergy Inverter

AWS

28

30

34

48

52

kW0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400

kW0 40 80 120 160 200 240 280 320 360 400 440 480

6,30 ÷ 16,1

22,0 ÷ 61,5

26,4 ÷ 42,2

55 ÷ 158

48 ÷ 155

270 ÷ 615

4,61 ÷ 13,2

20,5 ÷ 58,6

21,7 ÷ 38,1

47 ÷ 145

254 ÷ 583

177 ÷ 622

619 ÷ 2010

m3/h0 10.000 20.000 30.000 40.000 50.000 60.000 70.000 80.000 90.000 100.000 110.000 120.000

R-410ARefrigerant

PheExchanger

PheExchanger

R-407CRefrigerant

PheExchanger

R-407CRefrigerant

” R-134aRefrigerant

Inverter S&TExchanger

PheExchanger

R-407CRefrigerant

R-134aRefrigerant

S&TExchanger

PheExchanger

R-134aRefrigerant

S&TExchanger

R-410ARefrigerant

Inverter PheExchanger

FAN COILS

MF - vertikale Aufstellung (Boden)

MCK - Kassette

MCW - in die Decke integriert

MCC - in die Decke integrierte Kanalgeräte

MDB - große Kanalgeräte

MWM - Wandmontage

MCM - Zwischendecke

100

102

104

106

107

108

109

kW0 10 20 30 40 50 60 70 80 90 100 110 120

1,20 ÷ 8,302,2 ÷ 13,0

2,64 ÷ 10,83,42 ÷ 13,8

2,20 ÷ 9,802,40 ÷ 12,2

2,90 ÷ 15,83,37 ÷ 19,6

22,2 ÷ 44,022,9 ÷ 49,8

2,34 ÷ 5,283,02 ÷ 6,74

4,54 ÷ 13,25,72 ÷ 15,1

H2O

H2O

H2O

H2O

H2O

H2O

H2O

WATER COOLED CHILLERS

Ecoplus

PFS

WHS E

Proximus Evolution

WMC

WME (coming soon!)

WSC

WDC

68

72

74

80

86

90

92/94

93/96

kW0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400

161 ÷ 604

339 ÷ 1150

333 ÷ 1510

378 ÷ 2196

R-134aRefrigerant

FLDExchanger

S&TExchanger

R-134aRefrigerant

S&TExchanger

R-134aRefrigerant

S&TExchanger

R-410aRefrigerant

560 ÷ 4550

1120 ÷ 9485

R-134aRefrigerant

FLDExchanger

Inverter

R-134aRefrigerant

FLDExchanger

Inverter

329 ÷ 515R-134aRefrigerant

S&TExchanger

PheExchanger

Inverter

317 ÷ 1048

R-134aRefrigerant

S&TExchanger

PheExchanger

98 ÷ 413

1400 ÷ 2000R-134aRefrigerant

OIL FREE

FLDExchanger

Inverter

R-134aRefrigerant

OIL FREEFLDExchanger

Inverter

FREE COOLINGAWS “Free Cooling”60

kW0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400

619 ÷ 1349R-134aRefrigerant

S&TExchanger

free cooling

Page 16: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 17: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

AIR TO WATERHEAT PUMPS

15

Page 18: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

R-410ARefrigerant

PheExchanger

12

Minichiller R-410A - Heat PumpAIR TO WATER HEAT PUMP WITH ROTARY COMPRESSORS

Cooling capacity: 4,61 kW ÷ 13,6 kWHeating capacity: 6,30 kW ÷ 16,1 kW

STANDARD OPTIONS

Differential pressure switchHigh/low pressure switchBuilt-in hydronic kit:- water circulating pump with available head pressure from 65 to 200kPa (depending on the model)- expansion vessel- water filling/emptying kit- automatic safety and vent valve- insulated water buffer tank (single-compressor models)Condenser coil guardsAnti-freezing heater and sensorCompressor(s) anti-vibration mountsMicroprocessor based controlLCD Display - local or remote installationPre-set for low ambient kit

GENERAL CHARACTERISTICS

Rotary and Tandem Rotary Compressor supply the critical elements of high efficiency and high performance:- extremely tight tolerances between moving partsresulting in high compressor volumetric efficiency- minimised mechanical losses- minimised gas flow losses and turbulence- optimised compressor oil returnEvaporator made of brazed stainless steel plates, antifreeze protection sensor and heater; insulation with cell rubber foam; threaded water connectionsR410A refrigerantFinned coils with copper tubes mechanically expanded in aluminium finsAxial fansPanels and frame made of electro-galvanized steel polyester powder painted

OPTIONS ON REQUEST

Low ambient kitAdditional display

AIR TO W

ATER HEAT PU

MPS

16

EST

ation

he mpre

zing heatressor(s) anti-v

roprocessor basedCD Display - local or re-set for low ambien

play - lofor low a

kit ve

ffer tank (single-comp

rdaibration mountsd co

mote inst

alvenk (singl

nsor

p)

le m

essor

ng heessor(s) anti-

oprocessor baseD Display - local or

re-set for low ambie

kitvent valve

er tank (single-com

dsand sensbration mounts

controlmote ins

e head pmodel)

ssor

Page 19: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

TECHNICAL DATA Minichiller R-410A - heat pump

Minichiller R-410A - Heat PumpAIR TO WATER HEAT PUMP WITH ROTARY COMPRESSORS

17

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

020CR

128

1160

460

791

025CR

128

1160

460

791

030CR

128

1059

460

791

040CR

195

1059

460

1409

050CR

195

1059

460

1409

055CR

195

1059

460

1409

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 40/45°C entering/leaving condenser water temperature; 7°C ambient temperature, 90% R.H.(3) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Diameter

Evaporator

Hydraulic section

Pump type

Water Connections Size

Standard Voltage

kW

kW

--

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

kW

mm

Type

--

V/ph/Hz

4,61

2,62

1,76

6,30

2,59

2,43

58

1

-

1

1

0,14

457

1”

020CRMinichiller R-410A

5,69

2,83

2,01

7,33

2,79

2,63

59

1

-

1

1

0,14

457

High Head Circulator

1”

025CR

7,27

3,83

1,90

9,53

3,63

2,62

57

2

50

1

1

0,14

457

1”

030CR

10,0

5,00

2,00

12,6

4,65

2,71

59

2

40

1

2

0,14

457

1”

040CR

12,2

5,31

2,30

14,1

5,15

2,74

59

2

40

1

2

0,14

457

Horizontal Multistage End-Suction

1”

050CR

13,2

5,49

2,40

16,1

5,44

2,02

61

2

50

1

2

0,14

457

1”

055CR

Lanced Fins - Internally Spiral Wound Tubes

Rotary- Tandem Rotary

R-410A

Plate

220/240V / 1Ph / 50Hz

Axial

A B

C

A B

C

kg

mm

mm

mm

d-Su

0,14

457

C

28

1160

0

91

457

istage En

0,14

457

ultistage End-

1”

460

C

116

460

791

0

791

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 20: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR TO W

ATER HEAT PU

MPS

18

Minichiller Inverter R-410A - Heat PumpAIR TO WATER HEAT PUMP WITH INVERTER DRIVEN SCROLL COMPRESSORS

GENERAL CHARACTERISTICS

Inverter CompressorInverter compressor is programmed to run at the optimum speed, which is regulated by the input frequency as it varies according to the heat/cooling requirement. Inverter advantages are:• Fewer compressor starts - Frequency regulated compressor reduces the amount of times the compressor stop/starts which greatly reduces energy consumption.• Fast Cooling/heating - Inverter compressor has the ability to produce faster cooling/heating capacity by operating at a frequency higher than the dominant capacity frequency.• Smart capacity control - With integration of built in algorithm system, inverter compressor can match the heating/cooling load requirement exactly providing optimum energy efficiency.• Better compressor reliability - Inverter controlled compressor provides superior reliability due to the less frequent stop/starts especially at low load conditions.True Dual Circuits BPHEThe true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel.Elimination of Buffer VesselsThe Inverter system provides constant water set-point temperature control eliminating supply temperature fluctuations. With this form of control buffer vessels on mini chiller are not required.Built in Fan SpeedThe built in algorithm now controls the fan speed resulting in cost saving since installation of external FSC (Fan speed control) is not required.• Compressor, water pump overload protector

Safety Protection• High & low pressure switches• Anti-freeze protection sensor• Discharge temperature sensor• Over pressure relief valve• Water pressure differential switch• Anti-freeze heater on BPHE• Compressor, water pump overload protectorAnti Corrosion Heat ExchangerGold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller. Modular InstallationA network up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.

Cooling capacity: 20,5 kW ÷ 58,6 kWHeating capacity: 22,0 kW ÷ 61,5 kW

R-410ARefrigerant

PheExchanger

Inverter

e equiover

r reliability due to the lessy at low load conditions.

secouits (rff, eac

chan

es coating

of co

sychil

ntrolmade

aving sintrol) is not re

r, water pump ov

c

ow conte installatuir

rload prot

y c

ant water sg supply tentrol buffe

ls the fan of exte

cto

stallawork up to

trol on the operough the microp

water piping connecteft or right side of the

the piping coright side

switchPHE

ump overload protExcs offered as standard

xchanger of this se

50 chillers in a syation of the c

ocessor c

ngered as stager of t

cto

ate

er)even if

annel is

t-patu

on

ving sirol) is not re

, water pump o

ovideseliminatform o

red

videeliminaorm

ow continstallaired.

oad pro

ant water ssupply te

trol buff

s the fn of exte

work up to trol on the ope

rough the micropater piping connec

eft or right side of th

witchHE

mp overload proxchang

s offered as standardxchanger of this s

0 chillers in a sation of the

cessor

tor

te

er) inven if

nnel is

-pointture

on

Page 21: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

TECHNICAL DATA Minichiller Inverter R-410A - heat pump

Minichiller Inverter R-410A - Heat PumpAIR TO WATER HEAT PUMP WITH INVERTER DRIVEN SCROLL COMPRESSORS

19

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

075CR

200

1150

550

1460

100CR

405

1500

900

1245

135CR

525

1800

1150

1245

210CR

682

2093

1192

1786

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 40/45°C entering/leaving condenser water temperature; 7°C ambient temperature, 90% R.H.(3) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Diameter

Evaporator

Hydraulic section

Pump type

Water Connections Size

Standard Voltage

kW

kW

--

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

kW

mm

Type

--

V/ph/Hz

Minichiller Inverter R-410A

20,5

9,05

2,27

22,0

7,90

2,78

65

1

50

1

2

0,30

610

1”

075CR

27,8

12

2,32

29,3

11,4

2,57

63

1 + 1 scroll

50

1

2

0,50

600

1 1/4”

380/415V / 3Ph / 50Hz

100CR

38,5

15,8

2,44

41,5

16,3

2,55

67

1 + 1 scroll

50

1

2

1,43

660

1 1/4”

135CR

58,6

2,3

2,63

61,5

21,8

2,82

85

1 + 1 scroll

50

1

2

0,85

812

1 1/4”

210CR

Lanced Fins - Internally Spiral Wound Tubes

AC Inverter Scroll

R-410A

Plate

Axial

Horizontal Multistage End-Suction

A B

C

A B

C

A

C

kg

mm

mm

mm

2

C

1

5

46

R

0

10

4

1

C

5

14

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 22: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR TO W

ATER HEAT PU

MPS

20

Minichiller R-407C - Heat PumpAIR TO WATER HEAT PUMP WITH SCROLL COMPRESSORS

Cooling capacity: 21,7 kW ÷ 38,1 kWHeating capacity: 26,4 kW ÷ 42,2 kW

PheExchanger

R-407CRefrigerant

STANDARD OPTIONS

Differential pressure switchHigh/low pressure switchBuilt-in hydronic kit:- water circulating pump with available head pressure from 65 to 200kPa (depending on the model)- expansion vessel- water filling/emptying kit- automatic safety and vent valveCondenser coil guardsAnti-freezing heater and sensorCompressor(s) anti-vibration mountsMicroprocessor based controlLCD Display - local or remote installationPre-set for low ambient kit

GENERAL CHARACTERISTICS

Scroll compressorsEvaporator made of brazed stainless steel plates, with dual circuit in counter flow; antifreeze protection sensor and heater; insulation with cell rubber foam; threaded water connectionsR407C refrigerantFinned coils with copper tubes mechanically expanded in aluminium finsAxial fansPanels and frame made of electro-galvanized steel polyester powder paintedControl by microprocessor that allows the following functions- View: unit status (ON/OFF); operating mode (cooling/heating/boiler); set temperature; compressor(s) status (ON/OFF/defrost); alarms/errors. - Set: operating parameters & modes; defrost parameters; password; set and modify display settings; date and timer; 7-day programmable settings.With a single display it is also possible to control two units in the configuration Master & Slave.

OPTIONS ON REQUEST

Low ambient kitWater buffer tank (135 litres; separated module) Additional display

sepa

EST

play settings; date and timer;

possiSlave.

io

he mpre

pa ated modu

essor bsplay - local o

set for low ambie

kitve

dsa

viedr remote installatio

nt

enon moun

roli

le head p model)

nits

itres; seres;tres; s ed modted mod

play - localt for low ambsplay - local

et for low ambi

ent valve

nd sebration mounts

d contrremote installat

t kit

itven

sanibdremote installatio

t k

valve

seon mounttro

e inst

e head model)

e head pmodel)

tsits

Page 23: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

TECHNICAL DATA Minichiller R-407C - heat pump

Minichiller R-407C - Heat PumpAIR TO WATER HEAT PUMP WITH SCROLL COMPRESSORS

21

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

A B

C

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 40/45°C entering/leaving condenser water temperature; 7°C ambient temperature, 90% R.H.(3) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Diameter

Evaporator

Hydraulic section

Pump type

Water Connections Size

Standard Voltage

kW

kW

--

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

kW

mm

Type

--

V/ph/Hz

Minichiller R-407C

21,7

9,95

2,18

26,4

9,98

2,65

65

2

50

2

2

0,57

610

1 1/4”

080CR

25,8

11,0

2,35

28,7

11,1

2,59

66

2

50

2

2

0,57

610

1 1/4”

100CR

32,2

12,3

2,62

34,6

12,4

2,79

67

2

50

2

2

0,77

610

1 1/4”

120CR

38,1

15,1

2,52

42,2

15,8

2,67

69

2

50

2

2

1,53

610

1 1/4”

150CR

350

1500

900

1245

080CR

360

1500

900

1245

100CR

480

1800

1150

1245

120CR

560

1800

1150

1245

150CR

Horizotal Multistage End-Suction

380/415V / 3Ph / 50Hz

Plate

Scroll

R407C

Lanced Fins - Internally Spiral Would Tubes

kg

mm

mm

mm

0

12

R

0

00

0

5

R 1

1

0

0

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 24: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR TO W

ATER HEAT PU

MPS

22

McSmartAIR TO WATER HEAT PUMP WITH SCROLL COMPRESSORS

STANDARD OPTIONS

Phase monitorFans thermal relaysCompressors thermal relaysCondenser coils guardsCompressors guardsWater differential pressure switchHigh and low pressure manometersAnti vibration mounts

GENERAL CHARACTERISTICS

Scroll compressorsEvaporator made of brazed stainless steel plates, with double circuit; electrical heater to prevent freezing; insulation made of closed cells material; threaded water connectionsR407C refrigerantFinned coils with copper tubes mechanically expanded in aluminium finsAxial fansPanels and frame made of electro-galvanized steel polyester powder paintedControl by microprocessor compatible with Smart Manager system to manage McQuay hydronic systems

OPTIONS ON REQUEST

Low ambient kit2 pumps hydronic kitInertial tank

Cooling capacity: 47,1 kW ÷ 145 kWHeating capacity: 55,1 kW ÷ 158 kW

R-407CRefrigerant

PheExchanger

EST

witchano

tchnometers

witchanom

Page 25: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

TECHNICAL DATA McSmart - heat pump

McSmartAIR TO WATER HEAT PUMP WITH SCROLL COMPRESSORS

23

C

AB

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature(2) 40/45°C entering/leaving condenser water temperature; 7°C ambient temperature, 90% R.H.(3) At 1m, according to ISO 3744, at free field semispherical conditions

( ) Data referred to unit with pumps hydronic kit

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

160CR 190CR 210CR 240CR 320CR 400CR 500CR

kg

kg

mm

mm

mm

650 (674)

663 (687)

1820

1000

1935

676 (700)

691 (715)

1820

1000

1935

885 (920)

906 (941)

2056

1153

2185

928 (963)

964 (999)

2056

1153

2185

1206 (1241)

1226 (1261)

2750

1100

2180

1583 (1620)

1611 (1648)

2750

2200

2180

1988 (2154)

2024 (2190)

2750

2200

2180

Cooling Capacity1

Unit Power Input1

EER

ESEER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

47,1

19,7

2,39

3,51

55,1

21,0

2,63

65,8

2

50

2

2

0,72

715

710

1

8

31

Rc 1 1/2

52,9

21,5

2,46

3,61

57,1

22,1

2,58

67,0

2

50

2

2

0,72

715

710

1

9,5

23

Rc 1 1/2

63,6

24,8

2,56

3,76

67,2

27,0

2,49

67,2

2

50

1

2

0,72

715

800

1

10

30

Rc 1 1/2

75,6

28,5

2,65

3,90

81,8

30,0

2,73

66,9

2

50

1

2

0,72

715

800

1

12,8

31

Rc 1 1/2

96,0

39,3

2,44

3,59

110

41,8

2,63

71,0

4

25

2

2

1,9

715

800

1

12,3

44

Rc 2

113

44,0

2,57

3,66

118

48,2

2,45

71,0

4

25

2

4

0,72

715

800

1

18,0

48

Rc 2

145

53,7

2,70

3,97

158

60,3

2,62

72,0

4

25

2

4

0,72

715

800

1

25,5

75

Rc 2

160CRMcSmart 190CR 210CR 240CR 320CR 400CR 500CR

Lanced Fins - Internally Spiral Wound Tubes

Scroll

R-407C

Axial

Plate

400V / 3ph / 50Hz

Page 26: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR TO W

ATER HEAT PU

MPS

24

McEnergy HPI “Extension”AIR TO WATER HEAT PUMP WITH INVERTER DRIVEN SCREW COMPRESSORS

Cooling capacity: 254 kW ÷ 583 kWHeating capacity: 270 kW ÷ 615 kW

VERSIONS

EFFICIENCYSE Standard efficiency

NOISE LEVELSST Standard noiseLN Lowe noise

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Inverter driven Frame3100 single-screw compressors; Star-Delta standard startDirect expansion evaporator (shell and tubes); electrical heater to prevent freezing; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantCondenser coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuitsAxial fansMicro Tech II C Plus controller compatible with BMSCabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; RAL 7032

STANDARD OPTIONS

Inverter compressor starterDouble set pointFans thermal relaysPhase monitor10 mm evaporator insulationEvaporator electric heaterVictaulic water connectionsHour run meterGeneral fault relayElectronic expansion deviceLow pressure manometersSuction line shut-off valvesDischarge line shut-off valves

OPTIONS ON REQUEST

Partial heat recoveryBrine versionVoltage controlAbsorbed current limit / displayLow ambient kitCondenser coils guardsCu-Cu condenser coilsCu-Cu-Sn condenser coilsAlucoat condenser coils20 mm evaporator insulationFlow switchHigh pressure manometersRubber anti vibration mountsSpring anti vibration mounts1 pump hydronic kit2 pumps hydronic kit

EER up to 2,87ESEER up to 4,31

COP up to 3,04

75,9 ÷ 85,6 dB(A)(1) 72,3 ÷ 77,8 dB(A)

(2) 73,5 ÷ 78,6 dB(A)(1) Cooling mode(2) Heating mode

R-134aRefrigerant

Inverter S&TExchanger

ff v

S

R up to 2ER up tOP u

layxpansion device

ure manomene shut-off e line shu

lvoff va

n

1)

7

EEEOP

75,9 ÷ 85,2,3 ÷ 77,8

5 ÷ 78,6) C

O

Pa

yansion device

e manometerse shut-off valvesline shut-off valves

aypansion device

re manomee shut-off vline shut

alv-off va

tio

(

(2)

(1

) 7

ESECO

5,9 ÷ 853 ÷ 77,

÷ 78

SEO

5,9 ÷ 85,3 ÷ 77,8

÷ 78,

OO

P

Page 27: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

TO W

ATER

HEA

T PU

MPS

TECHNICAL DATA McEnergy HPI “Extension” SE ST - heat pump

McEnergy HPI “Extension”AIR TO WATER HEAT PUMP WITH INVERTER DRIVEN SCREW COMPRESSORS

25

C

A

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C evaporator water temperature; 35°C ambient temperature(2) 40/45°C condenser water temperature; 7°C DB ambient temperature(3) At 1m, according to ISO 3744, at free field semispherical conditions

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

Cooling Capacity1

Unit Power Input1

EER

ESEER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Cooling

Heating

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure drop

Cooling

Heating

Water Connections size

Standard Voltage

kW

kW

--

--

kW

kW

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

W

RPM

mm

Type

Nr

l

kPa

kPa

mm

V/ph/Hz

kg

kg

mm

mm

mm

254

90,3

2,81

4,05

270

90,4

2,98

82,1

82,1

2

13

R-134a

2

6

1,75

920

800

1

138

37

42

139,7

273

100

2,74

4,04

297

99,3

2,99

82,1

82,1

2

13

R-134a

2

6

1,75

920

800

1

138

42

49

139,7

292

109

2,69

4,01

324

107

3,03

82,1

82,3

2

3

R-134a

2

6

1,75

920

800

1

138

48

58

139,7

324

116

2,79

4,07

333

117

2,84

82,3

82,3

2

13

R-134a

2

8

1,75

920

800

1

133

53

55

139,7

339

124

2,74

4,01

349

124

2,80

82,3

82,3

2

13

R-134a

2

8

1,75

920

800

1

133

58

60

139,7

365

134

2,73

4,02

379

132

2,87

82,3

82,3

2

13

R-134a

2

8

1,75

920

800

1

128

53

60

139,7

382

142

2,68

3,94

410

141

2,90

82,3

82,5

2

13

R-134a

2

8

1,75

920

800

1

128

57

65

139,7

413

152

2,72

4,03

443

155

2,85

82,5

82,5

2

13

R-134a

2

10

1,75

920

800

1

128

46

52

139,7

436

163

2,68

4,01

463

165

2,81

82,5

83,7

2

13

R-134a

2

10

1,75

920

800

1

128

51

57

139,7

457

161

2,83

4,31

475

164

2,90

83,7

83,7

3

9

R-134a

3

12

1,75

920

800

1

240

61

66

219,1

505

178

2,83

4,13

530

176

3,02

83,7

83,7

3

9

R-134a

3

12

1,75

920

800

1

229

50

55

219,1

522

186

2,81

4,13

558

184

3,04

83,7

83,7

3

9

R-134a

3

12

1,75

920

800

1

229

50

60

219,1

583

215

2,71

4,05

615

205

3,00

83,7

83,7

3

9

R-134a

3

12

1,75

920

800

1

218

65

71

219,1

McEnergy HPI “Extension” SE ST

Single pass Shell & Tube

High efficiency fin and tube type with integral subcooler

Direct propeller

Semi-hermetic single screw compressor

400V / 3ph / 50Hz

072.2 079.2 083.2 093.2 096.2 103.2 109.2 117.2 124.2 130.3 144.3 153.3 167.3

072.2 079.2 083.2 093.2 096.2 103.2 109.2 117.2 124.2 130.3 144.3 153.3 167.3

3410

3550

3547

2254

2335

3455

3595

3547

2254

2335

3500

3640

3547

2254

2335

3870

4010

4381

2254

2335

3870

4010

4381

2254

2335

3940

4068

4381

2254

2335

4010

4138

4381

2254

2335

4390

4518

5281

2254

2335

4390

4518

5281

2254

2335

5015

5255

6583

2254

2335

5495

5724

6583

2254

2335

5735

5964

6583

2254

2335

5735

5953

6583

2254

2335

Page 28: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR TO W

ATER HEAT PU

MPS

26

McEnergy HPI “Extension”AIR TO WATER HEAT PUMP WITH INVERTER DRIVEN SCREW COMPRESSORS

TECHNICAL DATA McEnergy HPI “Extension” SE LN - heat pump

C

A

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C evaporator water temperature; 35°C ambient temperature(2) 40/45°C condenser water temperature; 7°C DB ambient temperature(3) At 1m, according to ISO 3744, at free field semispherical conditions

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

Cooling Capacity1

Unit Power Input1

EER

ESEER

Heating Capacity2

Unit Power Input2

COP

Sound Pressure Level3

Cooling

Heating

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Motor input

Cooling

Heating

Speed

Cooling

Heating

Diameter

Evaporator

Quantity

Water Volume

Pressure drop

Cooling

Heating

Water Connections size

Standard Voltage

kW

kW

--

--

kW

kW

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

W

W

RPM

RPM

mm

Type

Nr

l

kPa

kPa

mm

V/ph/Hz

kg

kg

mm

mm

mm

248

88,5

2,80

4,18

270

90,4

2,98

75,6

46,5

2

13

R-134a

2

6

0,78

1,75

715

920

800

1

138

36

42

139,7

266

98,4

2,70

4,16

297

99,3

2,99

75,6

75,6

2

13

R-134a

2

6

0,78

1,75

715

920

800

1

138

40

49

139,7

291

109

2,66

4,11

324

107

3,03

75,6

75,6

2

13

R-134a

2

6

0,78

1,75

715

920

800

1

138

48

58

139,7

316

113

2,79

4,29

333

117

2,84

75,8

77,2

2

13

R-134a

2

8

0,78

1,75

715

920

800

1

133

51

55

139,7

331

122

2,72

4,18

349

124

2,80

75,8

77,2

2

13

R-134a

2

8

0,78

1,75

715

920

800

1

133

55

60

139,7

355

132

2,68

4,16

379

132

2,87

75,8

77,2

2

13

R-134a

2

8

0,78

1,75

715

920

800

1

128

55

57

139,7

372

142

2,62

4,13

410

141

2,90

75,8

77,2

2

13

R-134a

2

8

0,78

1,75

715

920

800

1

128

55

65

139,7

403

149

2,71

4,19

443

155

2,85

76,0

77,4

2

13

R-134a

2

10

0,78

1,75

715

920

800

1

128

44

52

139,7

425

161

2,64

4,14

463

165

2,81

76,0

77,4

2

13

R-134a

2

10

0,78

1,75

715

920

800

1

128

48

57

139,7

448

156

2,87

4,31

475

164

2,90

77,2

78,6

3

9

R-134a

3

12

0,78

1,75

715

920

800

1

240

59

66

219,1

493

174

2,83

4,29

530

176

3,02

77,2

78,6

3

9

R134-a

3

12

0,78

1,75

715

920

800

1

229

48

55

219,1

510

183

2,79

4,23

558

184

3,04

77,2

78,6

3

9

R-134a

3

12

0,78

1,75

715

920

800

1

229

51

60

219,1

567

214

2,65

4,10

615

205

3,00

77,2

78,6

3

9

R-134a

3

12

0,78

1,75

715

920

800

1

218

62

71

219,1

McEnergy HPI “Extension” SE LN

Single pass Shell & Tube

High efficiency fin and tube type with integral subcooler

Direct propeller

Semi-hermetic single screw compressor

400V / 3ph / 50Hz

072.2 079.2 083.2 093.2 096.2 103.2 109.2 117.2 124.2 130.3 144.3 153.3 167.3

072.2 079.2 083.2 093.2 096.2 103.2 109.2 117.2 124.2 130.3 144.3 153.3 167.3

3750

3888

3547

2254

2335

3795

3933

3547

2254

2335

3840

3978

3547

2254

2335

4210

4343

4381

2254

2335

4210

4343

4381

2254

2335

4280

4408

4381

2254

2335

4350

4478

4381

2254

2335

4730

4858

5281

2254

2335

4730

4858

5281

2254

2335

5525

5765

6583

2254

2335

6005

6234

6583

2254

2335

6245

6474

6583

2254

2335

6245

6463

6583

2254

2335

Page 29: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR

COO

LED

CH

ILLE

RS

AIR COOLEDCHILLERS

27

Page 30: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

28

McSmartAIR COOLED CHILLER WITH SCROLL COMPRESSORS

STANDARD OPTIONS

Phase monitorFans thermal relaysCompressors thermal relaysCondenser coils guardsCompressors guardsWater differential pressure switchHigh and low pressure manometersAnti vibration mounts

GENERAL CHARACTERISTICS

Scroll compressorsEvaporator made of brazed stainless steel plates, with double circuit; electrical heater to prevent freezing; insulation made of closed cells material; threaded water connectionsR407C refrigerantFinned coils with copper tubes mechanically expanded in aluminium finsAxial fansPanels and frame made of electro-galvanized steel polyester powder paintedControl by microprocessor compatible with Smart Manager system to manage McQuay hydronic systems

OPTIONS ON REQUEST

Low ambient kit2 pumps hydronic kitInertial tank

Cooling capacity: 48 kW ÷ 155 kW

AIR COO

LED CH

ILLERS

R-407CRefrigerant

PheExchanger

EST

witchano

tchnometers

witchanom

Page 31: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McSmart - cooling only

McSmartAIR COOLED CHILLER WITH SCROLL COMPRESSORS

29

AIR

COO

LED

CH

ILLE

RS

C

AB

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature(2) At 1m, according to ISO 3744, at free field semispherical conditions

( ) Data referred to unit with pumps hydronic kit

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

160C 190C 210C 240C 320C 400C 500C

kg

kg

mm

mm

mm

637 (661)

650 (674)

1820

1000

1935

651 (675)

666 (690)

1820

1000

1935

843 (878)

864 (899)

2056

1153

2185

906 (941)

942 (977)

2056

1153

2185

1155 (1190)

1175 (1210)

2750

1100

2180

1543 (1580)

1571 (1607)

2750

2200

2180

1899 (2055)

1935 (2092)

2750

2200

2180

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

47,8

20,8

2,30

3,55

65,8

2

50

2

2

0,72

715

710

1

8,0

31

Rc 1 1/2

57,9

23,6

2,45

3,77

67,0

2

50

2

2

0,72

715

710

1

9,5

26

Rc 1 1/2

70,5

26,8

2,63

4,04

67,2

2

50

1

2

0,72

715

800

1

10,0

36

Rc 1 1/2

81,2

31,5

2,58

3,97

66,9

2

50

1

2

0,72

715

800

1

12,8

36

Rc 1 1/2

98,0

43,4

2,26

3,48

71,0

4

25

2

2

1,9

715

800

1

12,3

46

Rc 2

124

47,2

2,63

4,03

71,0

4

25

2

4

0,72

715

800

1

18,0

57

Rc 2

155

59,6

2,60

4,12

72,0

4

25

2

4

0,72

715

800

1

25,5

86

Rc 2

160CMcSmart 190C 210C 240C 320C 400C 500C

Lanced Fins - Internally Spiral Wound Tubes

Scroll

R-407C

Axial

Plate

400V / 3ph / 50Hz

Page 32: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

30

McEnergy MonoAIR COOLED CHILLER WITH SCREW COMPRESSORS

AIR COO

LED CH

ILLERS

VERSIONS

EFFICIENCYSE Standard efficiency

NOISE LEVELSST Standard noiseLN Low noise

GENERAL CHARACTERISTICS

Stepless capacity controlSingle screw compressor; star-Delta standard startDirect expansion evaporator (shell and tubes); electrical heater to prevent freezing; insulation made of closed cells materialR134a refrigerantCondensed coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuitsAxial fansMicro Tech III controller compatible with BMSCabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; colour Ivory White (Munsell code 5Y7.5/1) (±RAL7044)

STANDARD OPTIONS

Wye-Delta Compressors starter (Y-D) Double set-point Fans thermal overload relays Phase monitor Evaporator victaulic kitEvaporator electric heater10mm evaporator insulationElectronic expansion valveDischarge line shut off valve Suction line shut off valveLow pressure side manometersOutside ambient temperature sensor and set-point resetHour run meterGeneral fault contactor Set-point reset Demand limit Alarm from external device Fans circuit breakersMain switch interlock door

OPTIONS ON REQUEST

Total/ Partial heat recoverySoft starter Brine version Compressor thermal overload relays Under/Overvoltage controlEnergy Meter Capacitors for power factor correction Current limit 20mm evaporator insulationFan speed regulation Speedtrol Condenser coil guardsCu-Cu/Cu-Cu-Sn condenser coils Alucoat fins coils Evaporator flow switch High pressure side manometersRubber / Spring type anti vibration mounts Hydronic Kit (single water pump - low or high lifting) Hydronic Kit (twin water pumps - low or high lifting)(N.A. for SE 029.1 ST / LN and SE 034.1 ST / LN units)Double pressure relief valve with diverterCompressors circuit breakers

Cooling capacity: 98 kW ÷ 413 kW

EER up to 2,98(1)ESEER up to 3,34

(1) (Standard Noise)

73,5 ÷ 76,0 dB(A)71,0 ÷ 73,5 dB(A)

R-134aRefrigerant

PheExchanger

S&TExchanger

Page 33: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Mono SE ST - cooling only

McEnergy MonoAIR COOLED CHILLER WITH SCREW COMPRESSORS

31

AIR

COO

LED

CH

ILLE

RS

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES:(1) 12/7°C evaporator water temperature; 35°C ambient temperature(2) At 1 m, according to ISO 3744, at free field semispherical conditions

kg

kg

mm

mm

mm

Cooling Capacity 1

Unit Power Input 1

EER

ESEER

Sound Pressure Level 2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

--

V/ph/Hz

McEnergy Mono SE ST

101

38,7

2,61

2,93

73,5

1

25

R-134a

1

2

1,75

920

800

12

24

3”

029.1

1651

1663

2165

1292

2273

029.1

121

46,9

2,57

2,93

73,5

1

25

R-134a

1

2

1,75

920

800

15

25

3”

034.1

138

53,4

2,58

2,75

73,7

1

25

R-134a

1

3

1,75

920

800

17

24

3”

039.1

163

60,3

2,70

2,93

73,7

1

25

R-134a

1

3

1,75

920

800

20

24

3”

046.1

183

68,5

2,67

2,81

73,9

1

25

R-134a

1

4

1,75

920

800

24

22

3”

052.1

214

71,7

2,98

3,02

75,1

1

25

R-134a

1

4

1,75

920

800

30

21

3”

061.1

256

86,7

2,95

3,18

75,0

1

25

R-134a

1

6

1,75

920

800

25

48

3”

073.1

307

111

2,77

3,05

75,3

1

25

R-134a

1

6

1,75

920

800

30

48

3”

087.1

360

133

2,71

3,23

75,3

1

25

R-134a

1

6

1,75

920

800

36

48

3”

102,1

413

146

2,84

3,34

76,0

1

25

R-134a

1

6

1,75

920

800

44

45

3”

118,1

1684

1699

2165

1292

2273

034.1

1806

1823

3065

1292

2273

039.1

1861

1881

3065

1292

2273

046.1

2023

2047

3965

1292

2273

052.1

2086

2116

3965

1292

2273

061.1

2522

2547

3070

2236

2223

073.1

2745

2775

3070

2236

2223

087.1

2855

2891

3070

2236

2223

102,1

2919

2963

3070

2236

2223

118,1

Semi-hermetic single screw compressor Inverter driven

High efficiency fin and tube type with integral subcooler

Direct propeller type

Single Pass Shell&Tube

4000 V / 3ph / 50 Hz

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

C

A

B

Page 34: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

32

McEnergy MonoAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Mono SE LN - cooling only

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES:(1) 12/7°C evaporator water temperature; 35°C ambient temperature(2) At 1 m, according to ISO 3744, at free field semispherical conditions

Cooling Capacity 1

Unit Power Input 1

EER

ESEER

Sound Pressure Level 2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

--

V/ph/Hz

McEnergy Mono SE LN

97,9

38,8

2,52

3,01

71,0

1

25

R-134a

1

2

0,78

920

715

12

23

3”

029.1

116

47,9

2,42

2,97

71,0

1

25

R-134a

1

2

0,78

920

715

15

23

3”

034.1

134

53,0

2,53

2,85

71,2

1

25

R-134a

1

3

0,78

920

715

17

23

3”

039.1

157

60,4

2,60

3,00

71,2

1

25

R-134a

1

3

0,78

920

715

20

23

3”

046.1

177

67,8

2,61

3,07

71,4

1

25

R-134a

1

4

0,78

920

715

24

21

3”

052.1

209

72,1

2,89

3,32

72,6

1

25

R-134a

1

4

0,78

920

715

30

20

3”

061.1

249

84,5

2,95

3,55

72,5

1

25

R-134a

1

6

0,78

920

715

25

46

3”

073.1

296

110

2,69

3,41

72,8

1

25

R-134a

1

6

0,78

920

715

30

45

3”

087.1

345

134

2,58

3,34

72,8

1

25

R-134a

1

6

0,78

920

715

36

44

3”

102,1

398

150

2,65

3,45

73,5

1

25

R-134a

1

6

0,78

920

715

44

42

3”

118,1

Semi-hermetic single screw compressor Inverter driven

High efficiency fin and tube type with integral subcooler

Direct propeller

Single Pass Shell&Tube

4000 V / 3ph / 50 Hz

kg

kg

mm

mm

mm

1768

1780

2165

1292

2273

029.1

1801

1815

2165

1292

2273

034.1

1923

1940

3065

1292

2273

039.1

1978

1998

3065

1292

2273

046.1

2140

2164

3965

1292

2273

052.1

2203

2232

3965

1292

2273

061.1

2639

2664

3070

2236

2223

073.1

2862

2892

3070

2236

2223

087.1

2972

3008

3070

2236

2223

102,1

3036

3079

3070

2236

2223

118,1Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

C

A

B

Page 35: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 36: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

34

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

VERSIONS

EFFICIENCYSE Standard efficiency

Class A High efficiency

AMBIENT TEMPERATUREHA High ambient temperature

NOISE LEVELSST Standard noiseLN Lowe noiseXN Extra low noiseXXN Super quiet

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Frame3100 single-screw compressors; Star-Delta standard startDirect expansion evaporator (plate to plate / shell and tubes); electrical heater to prevent freezing; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantCondenser coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuitsAxial fansMicro Tech II C Plus controller compatible with BMSCabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; RAL 7032

STANDARD OPTIONS

Star-Delta startDouble set pointCompressors thermal relaysFans thermal relaysPhase monitor10 mm evaporator insulationEvaporator electric heaterVictaulic water connectionsHour run meterGeneral fault relayAlarm from external deviceLow pressure manometersSuction line shut-off valvesDischarge line shut-off valves

OPTIONS ON REQUEST

Total heat recovery for 2 circuits (100%)Total heat recovery for 1 circuit (50%)Partial heat recoveryElectronic expansion valvesBrine versionVoltage controlPower factor correctionAbsorbed current limit / displayLow ambient kitCondenser coils guardsCu-Cu condenser coilsCu-Cu-Sn condenser coilsAlucoat condenser coils20mm evaporator insulationFlow switch • High pressure manometersRubber anti vibration mountsSpring anti vibration mounts1 pump hydronic kit2 pumps hydronic kitInertial tank

Cooling capacity: 177 kW ÷ 622 kW

EER up to 2,93ESEER up to 3,77

EER up to 3,20ESEER up to 4,11

Up to 48°C

76,5 ÷ 79,0 dB(A)74,5 ÷ 77,5 dB(A)70,0 ÷ 73,5 dB(A)65,0 ÷ 66,0 dB(A)

AIR COO

LED CH

ILLERS

R-134aRefrigerant

PheExchanger

S&TExchanger

ne al

S

R up to 2ER up t

R u

nection

t relm external dure manom

ne shut-oe line shut-off valves

tevalv

t-off va

on

sea low noise

Su

per

7

EEE

ERR u

to

O

ToT

elayexternal device

re manometerse shut-off valves

shut-off valves

ectio

relaexternal de

ure manomne shut-o

line shut-off valves

eteff valve

ut-off va

elaayslay

non

ow noiseuper quiet

low noiseSup

ratureera re

ESEEE

ESEER

Up

SEEER

ER

p t

O

T

O

T

Page 37: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution SE ST - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

35

AIR

COO

LED

CH

ILLE

RS

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

111.2 125.2 132.2 142.2 152.2 158.2 165.2

kg

kg

mm

mm

mm

2960

3090

3139

2234

2223

4030

4195

4040

2234

2223

4220

4395

4040

2234

2223

4230

4395

4040

2234

2223

4230

4395

4040

2234

2223

4230

24395

4040

2234

2223

4235

4395

4040

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

389

152

2,56

3,36

76,5

2

13

2

6

1,75

890

800

1

130

46

168,3

436

164

2,66

3,54

77

2

13

2

6

1,75

890

800

1

165

38

168,3

466

167

2,79

3,55

77

2

13

2

8

1,75

890

800

1

175

67

168,3

502

184

2,73

3,52

77

2

13

2

8

1,75

890

800

1

165

47

168,3

532

194

2,74

3,52

78,5

2

13

2

8

1,75

890

800

1

165

52

168,3

556

205

2,72

3,56

79

2

13

2

8

1,75

890

800

1

165

57

168,3

578

197

2,93

3,39

79

2

13

2

8

1,75

890

800

1

160

51

168,3

111.2McEnergy Evolution SE ST 125.2 132.2 142.2 152.2 158.2 165.2

R-134a

Axial

Platte

400V / 3ph / 50Hz

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

Shell and Tube - Direct Expansion

Page 38: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

36

McEnergyAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy XXN - cooling only

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

056.2

3100

3200

3140

2235

2355

064.2

3475

3590

4040

2235

2355

070.2

3475

3590

4040

2235

2355

074.2

3475

3590

4040

2235

2355

078.2

3475

3590

4040

2235

2355

085.2

3475

3590

4040

2235

2355

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

203,0

79,8

2,54

3,39

65,0

2

12,5

2

6

0,45

500

710

1

90

36

4”

056.2McEnergy XXN

231,1

85,2

2,71

3,63

65,0

2

12,5

2

8

0,45

500

710

1

113

33

4”

064.2

252,7

93,7

2,70

3,52

65,0

2

12,5

2

8

0,45

500

710

1

113

38

4”

070.2

270,8

104,5

2,59

3,55

65,0

2

12,5

2

8

0,45

500

710

1

164

66

4”

074.2

286,1

114,5

2,50

3,44

65,0

2

12,5

2

8

0,45

500

710

1

159

46

4”

078.2

299,4

126,1

2,37

3,38

65,0

2

12,5

2

8

0,45

500

710

1

159

48

4”

085.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

C

A

B

kg

kg

mm

mm

mm

0

1

C

200

3

55

070.2

4

4”

064.2

2235

m

0

3140

2235

235

00

3140

355

70 2

1

159

6

1

46

2235

2355

0

2235

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 39: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution SE LN - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

37

AIR

COO

LED

CH

ILLE

RS

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

095.2 107.2 125.2 132.2 142.2 152.2 158.2

kg

kg

mm

mm

mm

2960

3090

3139

2234

2223

2960

3090

3190

2234

2223

4029

4194

4040

2234

2223

4224

4394

4040

2234

2223

4224

4394

4040

2234

2223

4229

4394

4040

2234

2223

4234

4394

4040

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

321

123

2,60

3,24

75

2

13

2

8

1,23

900

800

1

130

55

139,7

370

133

2,78

3,41

77,5

2

13

2

8

1,23

900

800

1

130

67

139,7

404

169

2,39

3,65

74,5

2

13

2

6

0,79

705

800

1

165

48

139,7

440

170

2,59

3,67

74,5

2

13

2

8

0,79

705

800

1

170

62

139,7

477

186

2,57

3,57

74,5

2

13

2

8

0,79

705

800

1

170

54

139,7

505

203

2,49

3,67

76

2

13

2

8

0,79

705

800

1

165

48

139,7

533

195

2,73

3,77

76,5

2

13

2

8

0,79

705

800

1

160

43

139,7

095.2McEnergy Evolution SE LN 107.2 125.2 132.2 142.2 152.2 158.2

R-134a

Axial

400V / 3ph / 50Hz

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

Shell and Tube - Direct Expansion

Page 40: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

38

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Evolution SE XN - cooling only

C

A

B

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

053.2 057.2 065.2 071.2 076.2 081.2 088.2

kg

kg

mm

mm

mm

2620

2650

2239

2234

2355

2620

2650

2239

2234

2355

2890

3100

3139

2234

2355

2890

3100

3139

2234

2355

2890

3100

3139

2234

2355

2890

3100

3139

2234

2355

2890

3100

3139

2234

2355

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Typ

Nr

%

Typ

Nr

Typ

Typ

Nr

kW

UPM

mm

Typ

Nr

l

kPa

mm

V/ph/Hz

177

84

2,11

2,89

70

2

13

2

4

0,88

680

710

1

25

27

88,9

190

82,7

2,30

3,00

70

2

13

2

4

0,88

680

710

1

30

20

88,9

219

85,2

2,57

3,34

70

2

13

2

6

0,88

680

710

1

100

55

114,3

238

94,7

2,51

3,21

70

2

13

2

6

0,88

680

710

1

100

47

114,3

252

103

2,44

3,23

70

2

13

2

6

0,88

680

710

1

100

51

114,3

265

111

2,38

3,16

70

2

13

2

6

0,88

680

710

1

100

55

114,3

278

122

2,28

3,13

70

2

13

2

6

0,88

680

710

1

100

55

114,3

053.2McEnergy Evolution SE XN 057.2 065.2 071.2 076.2 081.2 088.2

R-134a

Axial

Platte

400V / 3ph / 50Hz

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

Shell and Tube - Direct Expansion

Page 41: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution SE XN - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

39

AIR

COO

LED

CH

ILLE

RS

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

095.2 107.2 125.2 132.2 142.2 152.2 158.2

kg

kg

mm

mm

mm

3110

3240

3139

2234

2223

3110

3240

3139

2234

2223

4040

4342

4040

2234

2223

4240

4542

4040

2234

2223

4240

4542

4040

2234

2223

4240

4542

4040

2234

2223

4240

4542

4040

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

312

125

2,49

3,25

70

2

13

2

8

0,88

680

800

1

130

53

139,7

366

138

2,65

3,42

73

2

13

2

8

0,88

680

800

1

130

65

139,7

404

169

2,39

3,65

71

2

13

2

6

0,79

705

800

1

165

48

139,7

440

170

2,59

3,67

71

2

13

2

8

0,79

705

800

1

170

62

139,7

477

186

2,57

3,57

71

2

13

2

8

0,79

705

800

1

170

54

139,7

505

203

2,49

3,67

72,5

2

13

2

8

0,79

705

800

1

165

48

139,7

533

195

2,73

3,77

73

2

13

2

8

0,79

705

800

1

160

43

139,7

095.2McEnergy Evolution SE XN 107.2 125.2 132.2 142.2 152.2 158.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 42: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

40

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Evolution SE XXN - cooling only

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

057.2

3110

3200

3139

2234

2420

065.2

3475

3590

4040

2234

2420

071.2

3475

3590

4040

2234

2420

076.2

3425

3590

4040

2234

2420

081.2

3430

3590

4040

2234

2420

088.2

3430

3590

4040

2234

2420

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

203

79,9

2,54

3,39

65

2

13

2

6

0,45

500

710

1

90

45

114,3

057.2McEnergy Evolution SE XXN

231

85,2

2,71

3,63

65

2

13

2

8

0,45

500

710

1

115

34

114,3

065.2

253

93,5

2,70

3,52

65

2

13

2

8

0,45

500

710

1

115

38

114,3

071.2

271

104

2,59

3,55

65

2

13

2

8

0,45

500

710

1

165

38

114,3

076.2

286

114

2,50

3,44

65

2

13

2

8

0,45

500

710

1

160

35

114,3

081.2

299

126

2,50

3,39

65

2

13

2

8

0,45

500

710

1

160

38

114,3

088.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 43: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution XXN - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

41

AIR

COO

LED

CH

ILLE

RS

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

095.2

3430

3590

4040

2234

2420

111.2

3560

3735

4040

2234

2420

125.2

4302

4472

4040

2234

2420

142.2

4581

4746

4040

2234

2420

132.2

4506

4676

4040

2234

2420

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

309

136

2,27

3,25

65

2

13

2

8

0,45

500

710

1

90

45

114,3

095.2McEnergy Evolution SE XXN

370

148

2,49

3,24

65

2

13

2

8

0,6

500

800

1

115

34

114,3

111.2

413

169

2,44

3,49

65

2

13

2

8

0,6

500

800

1

170

44

139,7

125.2

451

173

2,60

3,61

66

2

13

2

9

0,6

500

800

1

170

50

139,7

132.2

492

187

2,63

3,58

66

2

13

2

10

0,6

500

800

1

165

45

139,7

142.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 44: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

42

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Evolution ClassA ST - cooling only

C

A

B

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

070.2

2905

3000

3138

2234

2355

078.2

3285

3400

4040

2234

2355

085.2

3285

3400

4040

2234

2355

093.2

3235

3400

4040

2234

2355

101.2

3240

3400

4040

2234

2355

107.2

3240

3400

4040

2234

2355

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

247

79,1

3,12

3,56

77,5

2

13

2

6

1,23

900

710

1

95

48

114,3

070.2McEnergy Evolution ClassA ST

275

87,1

3,16

3,60

77,5

2

13

2

8

1,23

900

710

1

115

45

114,3

078.2

302

94,1

3,20

3,62

77,5

2

13

2

8

1,23

900

710

1

115

49

114,3

085.2

327

104

3,15

3,85

77,5

2

13

2

8

1,23

900

710

1

165

46

114,3

093.2

351

113

3,12

3,67

77,5

2

13

2

8

1,16

900

710

1

160

51

114,3

101.2

376

120

3,14

3,58

79

2

13

2

8

1,75

890

710

1

160

58

114,3

107.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 45: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution ClassA ST - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

43

AIR

COO

LED

CH

ILLE

RS

C

A

B

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

116.2

3240

3400

4040

2234

2355

134.2

3510

3780

4040

2234

2223

149.2

4670

4940

4940

2234

2223

177.2

4685

4940

4940

2234

2223

164.2

4685

4940

4940

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

401

127

3,16

3,59

79

2

13

2

8

1,75

890

710

1

160

64

114,3

116.2McEnergy Evolution ClassA ST

469

150

3,12

3,84

79

2

13

2

8

1,75

890

800

1

270

47

168,3

134.2

524

166

3,15

4,00

79

2

13

2

10

1,75

890

800

1

270

63

168,3

149.2

575

181

3,18

4,01

79

2

13

2

10

1,75

890

800

1

255

56

168,3

164.2

622

194

3,20

3,88

79

2

13

2

10

1,75

890

800

1

255

38

168,3

177.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 46: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

44

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Evolution ClassA XN - cooling only

C

A

B

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

070.2

3005

3100

3138

2234

3138

078.2

3385

3500

4040

2234

4040

085.2

3385

3500

4040

2234

4040

093.2

3335

3500

4040

2234

4040

101.2

3340

3500

4040

2234

4040

107.2

3340

3500

4040

2234

4040

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

243

80,6

3,01

3,63

72,5

2

13

2

6

0,87

680

710

1

95

47

114,3

070.2McEnergy Evolution ClassA XN

272

87,0

3,12

3,70

72,5

2

13

2

8

0,88

680

710

1

115

44

114,3

078.2

296

95,1

3,11

3,69

72,5

2

13

2

8

0,88

680

710

1

115

48

114,3

085.2

322

106

3,05

3,82

72,5

2

13

2

8

0,88

680

710

1

165

45

114,3

093.2

345

115

2,99

3,71

72,5

2

13

2

8

0,88

680

710

1

160

49

114,3

101.2

370

119

3,12

4,01

73,5

2

13

2

8

0,79

705

710

1

160

56

114,3

107.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 47: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution ClassA XN - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

45

AIR

COO

LED

CH

ILLE

RS

C

A

B

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

116.2

3340

3500

4040

2235

2355

134.2

3610

3880

4040

2234

2223

149.2

4770

5040

4940

2234

2223

177.2

4785

5040

4940

2234

2223

164.2

4785

5040

4940

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

394

127

3,10

3,82

73,5

2

13

2

8

0,79

705

710

1

160

56

114,3

116.2McEnergy Evolution ClassA XN

455

152

2,99

3,89

73,5

2

13

2

8

0,79

705

800

1

270

45

168,3

134.2

512

167

3,07

4,11

73,5

2

13

2

10

0,78

705

800

1

270

60

168,3

149.2

561

183

3,07

4,11

73,5

2

13

2

10

0,78

705

800

1

255

54

168,3

164.2

600

198

3,03

3,93

73,5

2

13

2

10

0,78

705

800

1

255

36

168,3

177.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 48: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

AIR COO

LED CH

ILLERS

46

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA McEnergy Evolution HA ST - cooling only

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

053.2

2475

2500

2239

2234

2223

057.2

2470

2500

2239

2234

2223

065.2

2865

2960

3339

2234

2223

071.2

2865

2960

3339

2234

2223

076.2

2870

2960

3339

2234

2223

081.2

2870

2960

3339

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

195

77,2

2,52

3,11

77

2

13

2

4

1,75

890

710

1

25

32

88,9

053.2McEnergy Evolution HA ST

208

75,5

2,76

3,26

77

2

13

2

4

1,75

890

710

1

30

24

88,9

057.2

234

83,0

2,81

3,34

77

2

13

2

6

1,75

890

710

1

95

46

114,3

065.2

256

91

2,81

3,21

77

2

13

2

6

1,75

890

710

1

95

52

114,3

071.2

274

97,7

2,80

3,30

77

2

13

2

6

1,75

890

710

1

90

54

114,3

076.2

289

104

2,78

3,28

77

2

13

2

6

1,75

890

710

1

90

59

114,3

081.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

095.2

3185

3300

4040

2234

2223

336

120

2,80

3,25

77

2

13

2

8

1,75

890

710

1

115

58

114,3

095.2

088.2

2870

2960

3339

2234

2223

306

112

2,73

3,27

77

2

13

2

6

1,75

890

710

1

90

64

114,3

088.2

Page 49: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA McEnergy Evolution HA ST - cooling only

McEnergy EvolutionAIR COOLED CHILLER WITH SCREW COMPRESSORS

47

AIR

COO

LED

CH

ILLE

RS

C

A

B

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

107.2 119.2 128.2 134.2 149.2 156.2 167.2

kg

kg

mm

mm

mm

3185

3300

4040

2234

2223

3277

3447

4040

2234

2223

3942

4112

4040

2234

2223

4356

4526

4940

2234

2223

4361

4526

4940

2234

2223

4361

4526

4940

2234

2223

4366

4526

4940

2234

2223

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

381

127

3,0

3,57

77

2

13

2

8

1,75

890

710

1

115

70

139,7

415

141

2,94

3,61

77,5

2

13

2

8

1,75

890

800

1

170

46

139,7

448

150

2,98

3,68

77,5

2

13

2

8

1,75

890

800

1

170

53

139,7

478

162

2,95

3,68

77,5

2

13

2

10

1,75

890

800

1

170

58

139,7

514

175

2,94

3,66

77,5

2

13

2

10

1,75

890

800

1

165

51

139,7

547

182

3,00

3,71

79

2

13

2

10

1,75

890

800

1

165

56

139,7

587

191

3,07

3,79

79,5

2

13

2

10

1,75

890

800

1

160

53

139,7

107.2McEnergy Evolution HA ST 119.2 128.2 134.2 149.2 156.2 167.2

Lanced Fins - Internally Spiral Wound Tubes

McQuay Single Screw

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

Page 50: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

48

McEnergy InverterAIR COOLED CHILLER WITH INVERTER DRIVEN SCREW COMPRESSORS

VERSIONS

EFFICIENCYSSE Standard efficiency

XSE High efficiency

NOISE LEVELSST Standard noiseLN Low noiseXN Extra low noise (Only for XSE Efficiency)

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Frame 3100 single-screw compressors; Inverter technologyDirect expansion evaporator (plate to plate / shell and tubes); electrical heater to prevent freezing; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantCondenser coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuitsAxial fansMicro Tech II C Plus controller compatible with BMSCabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; RAL 7032

STANDARD OPTIONS

Inverter technologyDouble set pointCompressors thermal relaysFans thermal relaysPhase monitor10 mm evaporator insulationEvaporator electric heaterVictaulic water connectionsHour run meterGeneral fault relayAlarm from external deviceLow pressure manometersSuction line shut-off valvesDischarge line shut-off valves

OPTIONS ON REQUEST

Total heat recovery for 2 circuits (100%)Total heat recovery for 1 circuit (50%)Partial heat recoveryElectronic expansion valvesBrine versionVoltage controlPower factor correctionAbsorbed current limit / displayLow ambient kitCondenser coils guardsCu-Cu condenser coilsCu-Cu-Sn condenser coilsAlucoat condenser coils20mm evaporator insulationFlow switch • High pressure manometersRubber anti vibration mountsSpring anti vibration mounts1 pump hydronic kit2 pumps hydronic kitInertial tank

Cooling capacity: 329 kW ÷ 515 kW

EER bis 2,67ESEER bis 4,60

EER bis 2,79ESEER bis 5,01

83,0 ÷ 83,5 dB(A)77,0 ÷ 77,5 dB(A)73,0 ÷ 73,5 dB(A)

AIR COO

LED CH

ILLERS

R-134aRefrigerant

PheExchanger

S&TExchanger

Inverter

ne

te

S

EER bis 2ESEER b

EE

nection

t rem external deure manom

ne shut-line shut-off valves

etevalv

t-off va

on

for XSE E ci

877

ESEEE

0 ÷ 83,÷

O

To

ectio

relayexternal device

re manometerse shut-off valves

shut-off valves

nection

relayexternal de

ure manome shut-o

e shut-off valves

veter

ff valveut-off va

elaayslay

nn

r XSE ency)ie )

ESE

÷ 8

E

SE

0 ÷ 83

OO

T

Page 51: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

McEnergy InverterAIR COOLED CHILLER WITH INVERTER DRIVEN SCREW COMPRESSORS

49

AIR

COO

LED

CH

ILLE

RS

TECHNICAL DATA McEnergy Inverter SSE ST/LN

C

A

BB

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Lanced Fins - Internally Spiral Wound Tubes

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

094.2 102.2 113.2 122.2 131.2 139.2 147.2

kg

kg

kg

kg

mm

mm

mm

4190

4440

4340

4590

4381

2234

2355

4190

4440

4340

4590

4381

2234

2355

4590

4840

4740

4990

5281

2234

2355

4590

4840

4740

4990

5281

2234

2355

4990

5240

5140

5390

6181

2234

2355

4990

5240

5140

5390

6181

2234

2355

4990

5240

5140

5390

6181

2234

2355

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level ST2

Sound Pressure Level LN2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

329

120

2,74

4,59

83,0

77,0

2

13,5

2

8

1,13

700

800

1

271

60

168,3

358

136

2,63

4,60

83,0

77,0

2

13,5

2

8

1,13

700

800

1

264

61

168,3

395

147

2,68

4,55

83,0

77,0

2

13,5

2

10

1,13

700

800

1

264

72

168,3

423

159

2,66

4,59

83,0

77,0

2

13,5

2

10

1,13

700

800

1

256

67

168,3

459

168

2,74

4,57

83,5

77,5

2

13,5

2

12

1,13

700

800

1

256

78

168,3

488

181

2,71

4,70

83,5

77,5

2

13,5

2

12

1,13

700

800

1

248

69

168,3

515

193

2,67

4,60

83,5

77,5

2

13,5

2

12

1,13

700

800

1

248

76

168,3

094.2McEnergy SSE ST/LN 102.2 113.2 122.2 131.2 139.2 147.2

McQuay Single Screw

Page 52: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

50

AIRCOO

LED CH

ILLERS

C

A

B

McEnergy InverterAIR COOLED CHILLER WITH INVERTER DRIVEN SCREW COMPRESSORS

TECHNICAL DATA McEnergy Inverter XSE ST/LN/XN

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Lanced Fins - Internally Spiral Wound Tubes

R-134a

Axial

Shell and Tube - Direct Expansion

400V / 3ph / 50Hz

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

Shipping weight (XN)

Operating weight (XN)

(A) Length

(B) Width

(C) Height

094.2 102.2 113.2 122.2 131.2 139.2 147.2

kg

kg

kg

kg

kg

kg

mm

mm

mm

4190

4440

4340

4590

4390

4640

4381

2234

2355

4190

4440

4340

4590

4390

4640

4381

2234

2355

4590

4840

4740

4990

4790

5040

5281

2234

2355

4590

4840

4740

4990

4790

5040

5281

2234

2355

4990

5240

5140

5390

5190

5440

6181

2234

2355

4990

5240

5140

5390

5190

5440

6181

2234

2355

4990

5240

5140

5390

5190

5440

6181

2234

2355

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level ST2

Sound Pressure Level LN2

Sound Pressure Level XN2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

Nr

l

kPa

--

V/ph/Hz

329

118

2,78

4,79

83,0

77,0

73,0

2

13,5

2

8

0,90

700

800

1

271

60

168,3

358

135

2,66

4,82

83,0

77,0

73,0

2

13,5

2

8

0,90

700

800

1

264

61

168,3

395

145

2,73

4,78

83,0

77,0

73,0

2

13,5

2

10

0,90

700

800

1

264

72

168,3

423

157

2,70

4,84

83,0

77,0

73,0

2

13,5

2

10

0,90

700

800

1

256

67

168,3

459

165

2,79

4,81

83,5

77,5

73,5

2

13,5

2

12

0,90

700

800

1

256

78

168,3

488

178

2,75

5,01

83,5

77,5

73,5

2

13,5

2

12

0,90

700

800

1

248

69

168,3

515

190

2,71

4,84

83,5

77,5

73,5

2

13,5

2

12

0,90

700

800

1

248

76

168,3

094.2McEnergy XSE ST/LN/XN 102.2 113.2 122.2 131.2 139.2 147.2

McQuay Single Screw

Page 53: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 54: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

52

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

Cooling capacity: 619 kW ÷ 2008 kW

AIR COO

LED CH

ILLERS

R-134aRefrigerant

S&TExchanger

GENERAL CHARACTERISTICS

Stepless capacity control Independent circuit for each compressor Single-screw compressors; Star-Delta standard start Direct expansion shell and tube evaporators with single pass; shell and tube plates made of carbon steel; high efficiency copper tubes; electrical heater to prevent freezing insulation made of closed cells material; Victaulic water connections R134a refrigerant Condenser coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuits Direct propeller fans type Electronic expansion valves New controller compatible with BMS Cabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; RAL 7032

STANDARD OPTIONS

Wye Delta Compressors starter (Y-D) Double set-point Fans thermal overload relays Phase monitor Evaporator Victaulic kit on water connection 20mm evaporator insulation Evaporator electric heater Electronic Expansion Valve Discharge line shut off valves Ambient outside temperature sensor and set-point reset Hour run meter General fault relay Set-point reset and demand limit and alarm from external device Main switch interlock Auxiliary transformer Emergency stop Fans circuit breakers

OPTIONS ON REQUEST

Total or partial heat recovery Soft starterBrine version Compressor thermal overload relays Under/overvoltage Ampere volt meter Capacitor factor correction Current limit - display Fan speed regulation (VFD)Condenser coil guards Hydronic kit Compressor and evaporator area coil guards Cu-Cu or Cu-Cu-Sn condensing coils Alucoat condensing coils Evaporator flow switchSuction line shut off valves High pressure manometers Rubber or spring type anti vibration mounts Double pressure relief valves Automatic circuit breakers Compressors circuit breakers Ground fault relayAbsorbed current limit

VERSIONS

EFFICIENCY:SE Standard efficiency

XE High efficiency

PR Premium efficiency

NOISE LEVELS:ST Standard noiseLN Low noiseXN Extra low noise

EER up to 2,99(1)ESEER up to 4,08

EER up to 3,29(1)ESEER up to 4,35

EER up to 3,69(1)ESEER up to 4,53

(1) (Standard Noise)

79,0 ÷ 81,9 dB(A)75,5 ÷ 78,0 dB(A)71,0 ÷ 73,7 dB(A)

Page 55: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS SE ST/LN - cooling only

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

53

AIR

COO

LED

CH

ILLE

RS

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2 (ST)

Sound Pressure Level2 (LN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

AWS SE ST/LN

647

221

2,93

3,95

79,0

75,5

2

12,5

2

10

1,75

920

800

266

73

168,3

184.2

744

262

2,84

3,87

79,5

75,6

2

12,5

2

10

1,75

920

800

266

59

168,3

212.2

832

299

2,78

3,89

79,5

75,6

2

12,5

2

10

1,75

920

800

251

52

168,3

237.2

912

318

2,87

3,84

80,4

76,5

2

12,5

2

12

1,75

920

800

251

61

168,3

260.2

967

351

2,76

3,80

80,6

76,6

2

12,5

2

12

1,75

920

800

251

68

168,3

275.2

1064

378

2,82

3,88

80,6

76,8

2

12,5

2

14

1,75

920

800

243

63

168,3

303.2

1152

402

2,86

3,84

80,6

76,9

2

12,5

2

16

1,75

920

800

243

72

219,1

327.2

1419

500

2,84

3,88

81,0

77,2

3

12,5

3

20

1,75

920

800

421

47

219,1

403.3

1538

551

2,79

3,90

81,1

77,2

3

7

3

20

1,75

920

800

408

59

219,1

435.3

1622

580

2,8

3,87

81,1

77,3

3

7

3

22

1,75

920

800

408

65

219,1

461.3

1714

618

2,77

3,78

81,2

77,4

3

7

3

22

1,75

920

800

474

73

219,1

487.3

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Axial

Shell and Tube - Direct Expansion

400 V / 3ph / 50 Hz

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

kg

kg

kg

kg

mm

mm

mm

5630

5910

5920

6200

6185

2285

2540

184.2

5740

5990

6030

6280

6185

2285

2540

212.2

5760

6010

6050

6300

6185

2285

2540

237.2

6280

6530

6570

6820

6185

2285

2540

260.2

6560

6810

6850

7100

6185

2285

2540

275.2

7010

7250

7300

7540

7085

2285

2540

303.2

7280

7520

7570

7810

7985

2285

2540

327.2

10310

10730

10750

11170

10185

2285

2540

403.3

10320

10730

10770

11170

10185

2285

2540

435.3

10710

11110

11150

11550

11085

2285

2540

461.3

10770

11260

11210

11700

11085

2285

2540

487.3

R-134a

375.2 405.2 515.3 535.3 550.3

375.2 405.2 515.3 535.3 550.3

1319

441

2,99

4,08

80,7

77

2

12,5

2

18

1,75

920

800

386

54

219,1

7900

8280

8190

8570

8885

2285

2540

1418

474

2,99

4,07

80,7

77

2

12,5

2

18

1,75

920

800

386

58

219,1

7900

8280

8190

8570

8885

2285

2540

1802

665

2,71

3,79

81,5

77,9

3

7

3

22

1,75

920

800

850

36

273

11240

12110

12680

12560

11085

2285

2540

1875

682

2,75

3,81

81,9

78

3

7

3

24

1,75

920

800

850

39

273

11600

12480

12040

12920

11985

2285

2540

1922

714

2,69

3,77

81,9

78

3

7

3

24

1,75

920

800

850

40

273

11600

12480

12040

12920

11985

2285

2540

Page 56: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

AIR COO

LED CH

ILLERS

54

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA AWS SE XN - cooling only

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

AWS SE XN

619

223

2,77

4,08

71,0

2

12,5

2

10

0,78

715

800

266

67

168,3

184.2

715

272

2,62

3,96

71,5

2

12,5

2

10

0,78

715

800

266

55

168,3

212.2

789

315

2,51

3,98

71,5

2

12,5

2

10

0,78

715

800

251

47

168,3

237.2

876

331

2,65

3,99

72,0

2

12,5

2

12

0,78

715

800

251

57

168,3

260.2

922

369

2,5

4

72,5

2

12,5

2

12

0,78

715

800

251

62

168,3

275.2

1020

395

2,59

3,96

72,6

2

12,5

2

14

0,78

715

800

243

58

168,3

303.2

1112

417

2,67

3,96

72,6

2

12,5

2

16

0,78

715

800

243

68

168,3

327.2

1367

517

2,64

3,9

72,9

3

7

3

20

0,78

715

800

421

44

219,1

403.3

1471

576

2,55

3,87

73,0

3

7

3

20

0,78

715

800

408

54

219,1

435.3

1556

603

2,58

3,9

73,0

3

7

3

22

0,78

715

800

408

60

219,1

461.3

1623

647

2,51

3,83

73,1

3

7

3

22

0,78

715

800

474

66

219,1

487.3

Axial

400 V / 3ph / 50 Hz

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

5920

6200

6185

2285

2540

184.2

6030

6280

6185

2285

2540

212.2

6050

6300

6185

2285

2540

237.2

6570

6820

6185

2285

2540

260.2

6850

7100

6185

2285

2540

275.2

7300

7540

7085

2285

2540

303.2

7570

7810

7985

2285

2540

327.2

10750

11170

10185

2285

2540

403.3

10770

11170

10185

2285

2540

435.3

11150

11550

11085

2285

2540

461.3

11210

11700

11085

2285

2540

487.3

R-134a

375.2

375.2

405.2

405.2

515.3 535.3 550.3

515.3 535.3 550.3

1270

457

2,78

4,12

72,9

2

12,5

2

18

0,78

715

800

386

50

219,1

8190

8570

8885

2285

2540

1321

495

2,67

4,00

72,9

2

12,5

2

18

0,78

715

800

386

54

219,1

8190

8570

8885

2285

2540

1714

702

2,44

3,79

72,9

3

7

3

22

0,78

715

800

850

33

273

11680

12560

11085

2285

2540

1795

718

2,50

3,82

72,9

3

7

3

24

0,78

715

800

850

36

273

12040

12920

11985

2285

2540

1833

757

2,42

3,77

72,9

3

7

3

24

0,78

715

800

850

37

273

12040

12920

11985

2285

2540

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

McQuay Single Screw

Page 57: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS XE ST/LN - cooling only

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

55

AIR

COO

LED

CH

ILLE

RS

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level (ST)2

Sound Pressure Level (LN)2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

AWS XE ST/LN

756

233

3,25

4,02

79,7

76,3

2

12,5

2

12

1,75

920

800

251

80

168,3

830

253

3,28

4,11

79,7

76,5

2

12,5

2

14

1,75

920

800

243

56

168,3

889

278

3,2

4,02

79,7

76,5

2

12,5

2

14

1,75

920

800

243

64

168,3

1001

307

3,26

4,11

80,2

76,9

2

12,5

2

16

1,75

920

800

403

61

219,1

1074

338

3,18

4,05

80,7

77,1

2

12,5

2

16

1,75

920

800

403

69

219,1

1196

364

3,29

4,14

80,3

76,7

2

12,5

2

20

1,75

920

800

386

45

219,1

1280

400

3,2

4,02

80,4

76,8

2

12,5

2

20

1,75

920

800

386

51

219,1

1349

411

3,29

4,28

80,4

76,8

2

12,5

2

20

1,75

920

800

979

71

273

1409

437

3,23

4,23

80,5

77,1

3

7

3

24

1,75

920

800

491

77

219,1

1526

474

3,22

4,19

80,7

77,2

3

7

3

24

1,75

920

800

850

57

273

1596

504

3,17

4,17

80,9

77,3

3

7

3

24

1,75

920

800

850

62

273

1685

533

3,16

4,16

80,8

77,4

3

7

3

26

1,75

920

800

850

68

273

1768

561

3,15

4,13

81

77,5

3

7

3

28

1,75

920

800

871

64

273

1858

590

3,15

4,13

81

77,5

3

7

3

30

1,75

920

800

850

37

273

210.2 230.2 250.2 280.2 300.2 325.2 360.2 385.2 387.3 425.3 445.3 470.3 490.3 515.3

5990

6240

6280

6520

6185

2285

2540

6340

6580

6630

6870

7085

2285

2540

6360

6600

6650

6890

7085

2285

2540

7190

7600

7480

7880

7985

2285

2540

7470

7870

7760

8160

7985

2285

2540

8220

8610

8510

8900

9785

2285

2540

8240

8630

8530

8920

9785

2285

2540

8900

9890

9190

10180

9785

2285

2540

10560

11040

11000

11490

11985

2285

2540

11310

12170

11760

12610

11985

2285

2540

11570

12430

12010

12870

11985

2285

2540

11900

12760

12350

13200

12885

2285

2540

12260

13140

12700

13580

13785

2285

2540

12600

13470

13040

13910

14685

2285

2540

210.2 230.2 250.2 280.2 300.2 325.2 360.2 385.2 387.3 425.3 445.3 470.3 490.3 515.3

Axial

400 V / 3ph / 50 Hz

Weight and dimensions

Shipping weight (ST)

Operating weight (LN)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

kg

kg

kg

kg

mm

mm

mm

R-134a

402.2 434.2 540.3 555.3 570.3

402.2 434.2 540.3 555.3 570.3

1415

444

3,19

4,31

80,4

76,8

2

12,5

2

20

1,75

920

800

979

77

219,1

1525

475

3,21

4,35

80,4

76,8

2

12,5

2

20

1,75

920

800

979

84

273

8900

9890

9190

10180

9785

2285

2540

8900

9890

9190

10180

9785

2285

2540

1901

615

3,09

4,12

81

77,5

3

7

3

30

1,75

920

800

850

39

273

12600

13470

13040

13910

14685

2285

2540

1953

642

3,04

4,03

81

77,5

3

7

3

30

1,75

920

800

850

41

273

12600

13470

13040

13910

14685

2285

2540

2008

672

2,99

4,01

81

77,5

3

7

3

30

1,75

920

800

850

43

273

12600

13470

13040

13910

14685

2285

2540

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

McQuay Single Screw

Page 58: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

AIR COO

LED CH

ILLERS

56

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA AWS XE XN - cooling only

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

AWS XE XN

736

235

3,14

4,29

71,5

2

12,5

2

12

0,78

715

800

251

76

168,3

811

254

3,19

4,36

71,5

2

12,5

2

14

0,78

715

800

243

54

168,3

866

281

3,08

4,23

71,5

2

12,5

2

14

0,78

715

800

243

61

168,3

974

309

3,15

4,34

72,3

2

12,5

2

16

0,78

715

800

403

58

219,1

1041

343

3,03

4,24

72,5

2

12,5

2

16

0,78

715

800

403

65

219,1

1168

365

3,20

4,38

72,2

2

12,5

2

20

0,78

715

800

386

43

219,1

1247

404

3,08

4,25

72,3

2

12,5

2

20

0,78

715

800

386

49

219,1

1302

415

3,14

4,33

72,3

2

12,5

2

20

0,78

715

800

979

67

273

1378

438

3,15

4,34

72,6

3

7

3

24

0,78

715

800

491

74

219,1

1486

479

3,10

4,26

72,8

3

7

3

24

0,78

715

800

850

54

273

1550

513

3,03

4,26

72,9

3

7

3

24

0,78

715

800

850

59

273

1639

541

3,03

4,2

72,9

3

7

3

26

0,78

715

800

850

65

273

1722

567

3,04

4,21

73

3

7

3

28

0,78

715

800

871

61

273

1813

595

3,04

4,2

73

3

7

3

30

0,78

715

800

850

35

273

210.2 230.2 250.2 260.2 300.2 325.2 360.2 385.2 387.3 425.3 445.3 470.3 490.3 515.3

Axial

400 V / 3ph / 50 Hz

R-134a

402.2 434.2 540.3 555.3 570.3

6280

6520

6185

2285

2540

6630

6870

7085

2285

2540

6650

6890

7085

2285

2540

7480

7880

7985

2285

2540

7760

8160

7985

2285

2540

8510

8900

9785

2285

2540

8530

8920

9785

2285

2540

9190

10180

9785

2285

2540

11000

11490

11985

2285

2540

11760

12610

11985

2285

2540

12010

12870

11985

2285

2540

12350

13200

12885

2285

2540

12700

13580

13785

2285

2540

13040

13910

14685

2285

2540

210.2 230.2 250.2 260.2 300.2 325.2 360.2 385.2 387.3 425.3 445.3 470.3 490.3 515.3Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

402.2 434.2 540.3 555.3 570.3

1367

454

3,01

4,38

72,5

2

12,5

2

20

0,78

715

800

979

73

273

9190

10180

9785

2285

2540

1468

491

2,99

4,43

72,5

2

12,5

2

20

0,78

715

800

979

79

273

9190

10180

9785

2285

2540

1854

624

2,97

4,2

73,3

3

7

3

30

0,78

715

800

850

37

273

13040

13910

14685

2285

2540

1902

658

2,89

4,1

73,7

3

7

3

30

0,78

715

800

850

39

273

13040

13910

14685

2285

2540

1959

692

2,83

4,08

73,7

3

7

3

30

0,78

715

800

850

41

273

13040

13910

14685

2285

2540

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

McQuay Single Screw

Page 59: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS PR ST/LN - cooling only

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

57

AIR

COO

LED

CH

ILLE

RS

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

AWS PR ST/LN

821

225

3,64

4,44

79,5

76,9

2

12,5

R-134a

2

18

1,75

920

800

599

57

219,1

221.2

890

249

3,58

4,5

79,5

76,9

2

12,5

R-134a

2

18

1,75

920

800

599

65

219,1

243.2

975

274

3,56

4,41

79,5

76,9

2

12,5

R-134a

2

18

1,75

920

800

1043

30

273

266.2

1074

301

3,56

4,53

80,0

77,0

2

12,5

R-134a

2

20

1,75

920

800

1027

61

273

290.2

1158

330

3,51

4,39

80,5

77,1

2

12,5

R-134a

2

20

1,75

920

800

1027

69

273

313.2

2

1279

363

3,52

4,44

80,4

77,1

2

12,5

R-134a

22

1,75

920

800

995

60

273

350.2

1390

396

3,51

4,31

80,5

77,2

2

12,5

R-134a

2

24

1,75

920

800

979

73

273

378.2

400 V / 3ph / 50 Hz

kg

kg

kg

kg

mm

mm

mm

7530

8130

7820

8420

8885

2285

2540

7530

8130

7820

8420

8885

2285

2540

7660

8700

7950

8990

8885

2285

2540

8290

9330

8580

9620

9785

2285

2540

8550

9590

8840

9880

9785

2285

2540

9390

10380

10380

10670

11085

2285

2540

9730

10720

10720

11010

11985

2285

2540

221.2 243.2 266.2 290.2 313.2 350.2 378.2

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level (ST)2

Sound Pressure Level (LN)2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

Axial

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

420.2 444.2

420.2 444.2

1474

424

3,48

4,33

80,8

77,5

2

12,5

R-134a

2

24

1,75

920

800

979

81

273

9730

10720

10720

11010

11985

2285

2540

1562

453

3,45

4,32

81,1

77,8

2

12,5

R-134a

2

24

1,75

920

800

979

89

273

9730

10720

10720

11010

11985

2285

2540

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

McQuay Single Screw

Page 60: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

AIR COO

LED CH

ILLERS

58

AWSAIR COOLED CHILLER WITH SCREW COMPRESSORS

TECHNICAL DATA AWS PR XN - cooling only

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

AWS PR XN

809

219

3,69

4,63

71,2

2

12,5

R-134a

2

18

0,78

715

800

599

56

219,1

221.2

875

244

3,59

4,59

71,2

2

12,5

R-134a

2

18

0,78

715

800

599

63

219,1

243.2

956

272

3,51

4,54

71,2

2

12,5

R-134a

2

18

0,78

715

800

1043

29

273

266.2

1053

299

3,52

4,59

71,7

2

12,5

R-134a

2

20

0,78

715

800

1027

59

273

290.2

1132

330

3,43

4,5

72

2

12,5

R-134a

2

20

0,78

715

800

1027

66

273

313.2

1251

364

3,44

4,53

72

2

12,5

R-134a

2

22

0,78

715

800

995

58

273

350.2

1359

396

3,43

4,51

72

2

12,5

R-134a

2

24

0,78

715

800

979

60

273

378.2

400 V / 3ph / 50 Hz

kg

kg

mm

mm

mm

7820

8420

8885

2285

2540

7820

8420

8885

2285

2540

7950

8990

8885

2285

2540

8580

9620

9785

2285

2540

8840

9880

9785

2285

2540

10380

10670

11085

2285

2540

10720

11010

11985

2285

2540

221.2 243.2 266.2 290.2 313.2 350.2 378.2

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

Axial

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

420.2 444.2

420.2 444.2

1439

425

3,39

4,50

72,3

2

12,5

R-134a

2

24

0,78

715

800

979

77

273

10720

11010

11985

2285

2540

1521

457

3,33

4,45

72,6

2

12,5

R-134a

2

24

0,78

715

800

979

84

273

10720

11010

11985

2285

2540

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

McQuay Single Screw

Page 61: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

FREE

CO

OLI

NGFREE COOLING

59

Page 62: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

60

AWS “Free Cooling”AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

Cooling capacity: 619 kW ÷ 1349 kW

FREE COO

LING

R-134aRefrigerant

S&TExchanger

GENERAL CHARACTERISTICS

Stepless capacity control Independent circuit for each compressor Single-screw compressors; Star-Delta standard start Direct expansion shell and tube evaporators with single pass; shell and tube plates made of carbon steel; high efficiency copper tubes; electrical heater to prevent freezing insulation made of closed cells material; Victaulic water connections R134a refrigerant Condenser coils with copper tubes mechanically expanded in aluminium fins; sub-cooler circuits Direct propeller fans type Electronic expansion valves New controller compatible with BMS Cabinet and structure made of galvanized steel sheet and painted to provide high resistance to corrosion; RAL 7032

STANDARD OPTIONS

Wye Delta Compressors starter (Y-D) Double set-point Fans thermal overload relays Phase monitor Evaporator Victaulic kit on water connection 20mm evaporator insulation Evaporator electric heater Electronic Expansion Valve Discharge line shut off valves Ambient outside temperature sensor and set-point reset Hour run meter General fault relay Set-point reset and demand limit and alarm from external device Main switch interlock Auxiliary transformer Emergency stop Fans circuit breakers

OPTIONS ON REQUEST

Total or partial heat recovery Soft starterBrine version Compressor thermal overload relays Under/overvoltage Ampere volt meter Capacitor factor correction Current limit - display Fan speed regulation (VFD)Condenser coil guards Hydronic kit Compressor and evaporator area coil guards Cu-Cu or Cu-Cu-Sn condensing coils Alucoat condensing coils Evaporator flow switchSuction line shut off valves High pressure manometers Rubber or spring type anti vibration mounts Double pressure relief valves Automatic circuit breakers Compressors circuit breakers Ground fault relay

Free cooling with system seperation

free cooling

VERSIONS

EFFICIENCY:SE Standard efficiency

XE High efficiency

PR Premium efficiency

NOISE LEVELS:ST Standard noiseLN Low noiseXN Extra low noise

EER up to 2,93(1)ESEER up to 3,96

EER / FC up to 90,39

EER up to 3,29(1)ESEER up to 4,23

EER / FC up to 90,39

EER up to 3,64(1)ESEER up to 4,53

EER / FC up to 90,39(1) (Standard Noise)

79,0 ÷ 81,2 dB(A)75,5 ÷ 77,5 dB(A)71,0 ÷ 73,1 dB(A)

Free Cooling

Absorbed current limit

Page 63: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS SE ST/LN - FC

61

FREE

CO

OLI

NG

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

AWS „Free Cooling“AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS SE ST/LN - FC 184.2 212.2 237.2 260.2 275.2 303.2 327.2

Axial

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

kg

kg

kg

kg

mm

mm

mm

5630

5910

5920

6200

7185

2285

2540

184.2

5740

5990

6030

6280

7185

2285

2540

212.2

5760

6010

6050

6300

7185

2285

2540

237.2

6280

6530

6570

6820

7185

2285

2540

260.2

6560

6810

6850

7100

7185

2285

2540

275.2

7010

7250

7300

7540

8085

2285

2540

303.2

7280

7520

7570

7810

8985

2285

2540

327.2

400 V / 3ph / 50 Hz

1152

402

2,86

3,84

80,6

76,9

3

12,5

R-134a

2

16

1,75

920

800

243

72

219,1

1064

378

2,82

3,88

80,6

76,8

2

12,5

R-134a

2

14

1,75

920

800

243

63

168,3

967

351

2,76

3,80

80,6

76,6

2

12,5

R-134a

2

12

1,75

920

800

251

68

168,3

912

318

2,87

3,84

80,4

76,5

2

12,5

R-134a

2

12

1,75

920

800

251

61

168,3

832

299

2,78

3,89

79,5

75,6

2

12,5

R-134a

2

10

1,75

920

800

251

52

168,3

744

262

2,84

3,87

79,5

75,6

2

12,5

R-134a

2

10

1,75

920

800

266

59

168,3

647

221

2,93

3,95

79,0

75,5

2

12,5

R-134a

2

10

1,75

920

800

266

73

168,3

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 ST (LN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 64: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

FREE COO

LING

62

AWS “Free Cooling”AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

TECHNICAL DATA AWS SE XN - FC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS SE XN - FC 184.2 212.2 237.2 260.2 275.2 303.2 327.2

Axial

400 V / 3ph / 50 Hz

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 (XN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

619

223

2,77

389

49,87

71,0

2

12,5

R-134a

2

10

0,78

715

800

266

67

168,3

715

272

2,62

389

49,87

71,5

2

12,5

R-134a

2

10

0,78

715

800

266

55

168,3

789

315

2,51

389

49,87

71,5

2

12,5

R-134a

2

10

0,78

715

800

251

47

168,3

876

331

2,65

467

49,89

72,0

2

12,5

R-134a

2

12

0,78

715

800

251

57

168,3

922

369

2,5

467

49,89

72,5

2

12,5

R-134a

2

12

0,78

715

800

251

62

168,3

1020

395

2,59

545

49,91

72,6

2

12,5

R-134a

2

14

0,78

715

800

243

58

168,3

1112

417

2,67

623

49,92

72,6

2

12,5

R-134a

2

16

0,78

715

800

243

68

168,3

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

184.2 212.2 237.2 260.2 275.2 303.2 327.2

5920

6200

7185

2285

2540

6030

6280

7185

2285

2540

6050

6300

7185

2285

2540

6570

6820

7185

2285

2540

6850

7100

7185

2285

2540

7300

7540

8085

2285

2540

7570

7810

8985

2285

2540

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 65: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS XE ST/LN - FC

63

FREE

CO

OLI

NG

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

AWS „Free Cooling“AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS XE ST/LN - FC

Axial

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

kg

kg

kg

kg

mm

mm

mm

400 V / 3ph / 50 Hz

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 ST (LN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

756

233

3,25

555

26,43

79,7 (76,3)

2

12,5

R-134a

2

12

1,75

920

800

251

80

168,3

830

253

3,28

648

26,45

79,7 (76,5)

2

12,5

R-134a

2

14

1,75

920

800

243

56

168,3

889

278

3,2

648

26,45

79,7 (76,5)

2

12,5

R-134a

2

14

1,75

920

800

243

64

168,3

1001

307

3,26

740

26,43

80,2 (76,9)

2

12,5

R-134a

2

16

1,75

920

800

403

61

219,1

1074

338

3,18

740

26,43

80,7 (77,1)

2

12,5

R-134a

2

16

1,75

920

800

403

69

219,1

1196

364

3,29

926

26,46

80,3 (76,7)

2

12,5

R-134a

2

20

1,75

920

800

386

45

219,1

1280

400

3,2

926

26,46

80,4 (76,8)

2

12,5

R-134a

2

20

1,75

920

800

386

51

219,1

1349

411

3,29

926

26,46

80,4 (76,8)

2

12,5

R-134a

2

20

1,75

920

800

979

71

273

210.2 230.2 250.2 280.2 300.2 325.2 360.2 385.2

5990

6240

6280

6520

7185

2285

2540

6340

6580

6630

6870

8085

2285

2540

6360

6600

6650

6890

8085

2285

2540

7190

7600

7480

7880

8985

2285

2540

7470

7870

7760

8160

8985

2285

2540

8220

8610

8510

8900

10785

2285

2540

8240

8630

8530

8920

10785

2285

2540

8900

9890

9190

10180

10785

2285

2540

210.2 230.2 250.2 280.2 300.2 325.2 360.2 385.2

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 66: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

FREE COO

LING

64

AWS “Free Cooling”AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

TECHNICAL DATA AWS XE XN - FC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS XE XN - FC 210.2 230.2 250.2 260.2 300.2 325.2

Axial

400 V / 3ph / 50 Hz

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 (XN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

736

235

3,14

467

49,89

71,5

2

12,5

R-134a

2

12

0,78

715

800

251

76

168,3

811

254

3,19

545

49,91

71,5

2

12,5

R-134a

2

14

0,78

715

800

243

54

168,3

866

281

3,08

545

49,91

71,5

2

12,5

R-134a

2

14

0,78

715

800

243

61

168,3

974

309

3,15

623

49,92

72,3

2

12,5

R-134a

2

16

0,78

715

800

403

58

219,1

1041

343

3,03

623

49,92

72,5

2

12,5

R-134a

2

16

0,78

715

800

403

65

219,1

1168

365

3,20

623

49,87

72,2

2

12,5

R-134a

2

20

0,78

715

800

386

43

219,1

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

210.2 230.2 250.2 260.2 300.2 325.2

6280

6520

7185

2285

2540

6630

6870

8085

2285

2540

6650

6890

8085

2285

2540

7480

7880

8985

2285

2540

7760

8160

8985

2285

2540

8510

8900

10785

2285

2540

360.2 385.2

1247

404

3,08

778

49,87

72,3

2

12,5

R-134a

2

20

0,78

715

800

386

49

219,1

1302

415

3,14

778

49,87

72,3

2

12,5

R-134a

2

20

0,78

715

800

979

67

219,1

360.2 385.2

8530

8920

10785

2285

2540

9190

10180

10785

2285

2540

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 67: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA AWS PR ST/LN - FC

65

FREE

CO

OLI

NG

A

C

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

AWS „Free Cooling“AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS PR ST/LN - FC

Axial

Weight and dimensions

Shipping weight (ST)

Operating weight (ST)

Shipping weight (LN)

Operating weight (LN)

(A) Length

(B) Width

(C) Height

kg

kg

kg

kg

mm

mm

mm

400 V / 3ph / 50 Hz

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 ST (LN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

821

225

3,64

833

26,44

79,5 (76,9)

2

12,5

R-134a

2

18

1,75

920

800

599

57

219,1

890

249

3,58

833

26,44

79,5 (76,9)

2

12,5

R-134a

2

18

1,75

920

800

599

65

219,1

975

274

3,56

833

26,44

79,5 (76,9)

2

12,5

R-134a

2

18

1,75

920

800

1043

30

273

1074

301

3,56

926

26,46

80,0 (77,0)

2

12,5

R-134a

2

20

1,75

920

800

1027

61

273

1158

330

3,51

926

26,46

80,5 (77,1)

2

12,5

R-134a

2

20

1,75

920

800

1027

69

273

221.2 243.2 266.2 290.2 312.2

7530

8130

7820

8420

9885

2285

2540

7530

8130

7820

8420

9885

2285

2540

7660

8700

7950

8990

9885

2285

2540

8290

9330

8580

9620

10785

2285

2540

8550

9590

8840

9880

10785

2285

2540

221.2 243.2 266.2 290.2 313.2

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 68: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A

C

B

FREE COO

LING

66

AWS “Free Cooling”AIR COOLED CHILLER WITH SCREW COMPRESSORSAND INTEGRATED FREE COOLING

TECHNICAL DATA AWS PR XN - FC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 35°C ambient temperature.(2) 16/10°C entering/leaving evaporator water temperature; 5°C ambient temperature; 30% brine; without running compressor(3) At 1m, according to ISO 3744, at free field semispherical conditions.

AWS PR XN - FC

Axial

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

400 V / 3ph / 50 Hz

Cooling Capacity1

Unit Power Input1

EER

Free cooling

Cooling Capacity2

EER - Free cooling

Sound Pressure Level3 (XN)

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Condenser Coil

Fan

Quantity

Power Input

Speed

Diameter

Evaporator

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Type

Nr

kW

RPM

mm

Type

l

kPa

mm

V/ph/Hz

809

219

3,69

700

49,86

71,2

2

12,5

R-134a

2

18

0,78

715

800

599

56

219,1

875

244

3,59

700

49,86

71,2

2

12,5

R-134a

2

18

0,78

715

800

599

63

219,1

956

272

3,51

700

49,86

71,2

2

12,5

R-134a

2

18

0,78

715

800

1043

29

273

1053

299

3,52

778

49,87

71,7

2

12,5

R-134a

2

20

0,78

715

800

1027

59

273

1132

330

3,43

778

49,87

72

2

12,5

R-134a

2

20

0,78

715

800

1027

66

273

221.2 243.2 266.2 290.2 312.2

7820

8420

9885

2285

2540

7820

8420

9885

2285

2540

7950

8990

9885

2285

2540

8580

9620

10785

2285

2540

8840

9880

10785

2285

2540

221.2 243.2 266.2 290.2 313.2

McQuay Single Screw

High efficiency fin and tube type with integral subcooler

Shell and Tube - Direct Expansion

Page 69: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WAT

ER C

OO

LED

CH

ILLE

RS

WATER COOLEDCHILLERS

67

Page 70: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

68

EcoplusWATER COOLED CHILLER WITH SCREW COMPRESSORS

Cooling capacity: 166 kW ÷ 604 kW

WATER CO

OLED

CHILLERS

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Frame3200 single-screw compressors; Star-Delta standard startDirect expansion shell and tube evaporator with single pass; shell and tube plates made of carbon steel; high efficiency copper tubes; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantShell and tube condensers; one per each circuit; shell and tube plates made of carbon steel; high efficiency copper tubes; GAS water connectionsMicro Tech II C Plus controller compatible with BMS

STANDARD OPTIONS

Star-Delta startDouble set pointPhase monitorVictaulic water connections for evaporatorGAS water connections for condensers10 mm evaporator insulationManometersHour run meterGeneral fault relayAlarm from external deviceSuction line shut-off valvesDischarge line shut-off valves

OPTIONS ON REQUEST

Condenserless with liquid receivers (SE version only)Condenserless without liquid receivers (SE version only)Total heat recoveryPartial heat recoverySoft starterHeat pump versionBrine versionCompressors thermal relaysVoltage controlAmmeter and voltmeterPower factor correctionAbsorbed current limit / display20 mm evaporator insulation / condensers insulationVictaulic water connections for condensersFlanged water connections for condensersCondensers with Cu-Ni 90-10 tubesEvaporator flow switchCondenser flow switchRubber anti vibration mountsCompressors soundproof cabinet

R-134aRefrigerant

S&TExchanger

NS

for evonde

elayexternal device

e shut-off ve line shut-off v

eonde

on

aper

O

C

ayternal device

shut-off valvesline shut-off valves

ayxternal device

e shut-off valine shut-off valvesff va

ions foor

onsons fnd

nonde

on

poratorrs

poers

OO

C

VERSIONEN

EFFICIENCYSE Standard efficiency

XE High efficiency

SE ME CondenserlessSE LR Condenserless with liquid receiver

NOISE LEVELS:ST Standard noise

EER up to 4,00ESEER up to 5,33

EER up to 4,73ESEER up to 6,31

EER up to 3,70ESEER up to 3,70

69,7 ÷ 71,7 dB(A)

Page 71: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA Ecoplus SE ST

EcoplusWATER COOLED CHILLER WITH SCREW COMPRESSORS

69

WAT

ER C

OO

LED

CH

ILLE

RS

C

BA

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

50.1

1393

1470

3435

920

1860

60.1

1410

1480

3435

920

1860

73.1

1503

1650

3435

920

1860

80.1

1503

1650

3435

920

1860

100.2

2687

2840

4305

860

1880

110.2

2697

2850

4305

860

1880

120.2

2702

2860

4305

860

1880

133.2

2757

2970

4305

860

1880

146.2

2762

2970

4305

860

1880

165.2

2762

2970

4305

860

1880

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

166

42,1

3,93

5,00

69,7

1

25

1

1

60

48

88,9

1

13

38

5”

50.1

201

50,7

3,97

5,04

69,7

1

25

1

1

56

69

88,9

1

15

41

5”

60.1

253

64,9

3,90

4,95

69,7

1

25

1

1

123

43

114,3

1

15

63

5”

73.1

280

75,4

3,72

4,72

69,7

1

25

1

1

123

53

114,3

1

15

77

5”

80.1

334

84,3

3,96

5,28

71,7

2

12,5

1

1

118

64

114,3

2

26

40

5”

100.2

372

93,1

4,00

5,33

71,7

2

12,5

1

1

113

63

114,3

2

28

41

5”

110.2

403

101

3,97

5,29

71,7

2

12,5

1

1

113

72

114,3

2

30

41

5”

120.2

448

115

3,89

5,19

71,7

2

12,5

1

1

173

54

139,7

2

30

50

5”

133.2

494

129

3,83

5,10

71,7

2

12,5

1

1

168

54

139,7

2

30

60

5”

146.2

556

150

3,70

4,93

71,7

2

12,5

1

1

168

68

139,7

2

30

75

5”

165.2Ecoplus SE ST

R-134a

400V / 3ph / 50Hz

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 72: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

70

EcoplusWATER COOLED CHILLER WITH SCREW COMPRESSORS

WATER CO

OLED

CHILLERS

TECHNICAL DATA Ecoplus XE ST

C

BA

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

1650

1800

3435

920

1860

1665

1810

3435

920

1860

1680

1820

3435

920

1860

1680

1820

3435

920

1860

2800

3020

4305

860

1880

2945

3280

4305

860

1880

2955

3290

4305

860

1880

2975

3315

4305

860

1880

2990

3340

4305

860

1880

2990

3340

4305

860

1880

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

186

39,7

4,70

5,97

69,7

1

25

1

1

125

25

114,3

1

22

17

5”

050.1

223

48,1

4,64

5,90

69,7

1

25

1

1

120

35

114,3

1

25

20

5”

060.1

277

59,3

4,66

5,92

69,7

1

25

1

1

110

35

114,3

1

25

25

5”

073.01

307

71,4

4,29

5,46

69,7

1

25

1

1

110

44

114,3

1

25

28

5”

080.1

366

79,3

4,62

6,15

71,7

2

12,5

1

1

170

30

139,7

2

44

17

5”

100.2

408

87,2

4,68

6,24

71,7

2

12,5

1

1

285

24

168,3

2

47

17

5”

110.2

444

95

4,67

6,23

71,7

2

12,5

1

1

285

28

168,3

2

50

17

5”

120.2

496

105

4,73

6,31

71,7

2

12,5

1

1

280

39

168,3

2

59

16

5”

133.2

541

114

4,72

6,30

71,7

2

12,5

1

1

280

46

168,3

2

68

15

5”

146.2

604

138

4,39

5,85

71,7

2

12,5

1

1

280

57

168,3

2

68

19

5”

165.2

050.1 060.1 073.01 080.1 100.2 110.2 120.2 133.2 146.2 165.2

Ecoplus XE ST

R-134a

400V / 3ph / 50Hz

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 73: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA Ecoplus SE ME/LR

EcoplusWATER COOLED CHILLER WITH SCREW COMPRESSORS

71

WAT

ER C

OO

LED

CH

ILLE

RS

C

BA

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

R-134a

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

050.1

1280

1337

3700

1000

1860

060.1

1280

1337

3700

1000

1860

073.1

1398

1516

3700

1000

1860

080.1

1398

1516

3700

1000

1860

100.2

2442

2560

4400

1100

1942

110.2

2446

2560

4400

1100

1942

120.2

2446

2560

4400

1100

1942

133.2

2501

2670

4400

1100

1942

146.2

2506

2670

4400

1100

1942

165.2

2506

2670

4400

1100

1942

Cooling Capacity1

Unit Power Input1

EER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

V/ph/Hz

161

45,4

3,54

69,7

1

25

1

1

60

48

88,9

050.1

189

54,3

3,48

69,7

1

25

1

1

56

69

88,9

060.1

244

65,9

3,70

69,7

1

25

1

1

123

43

114,3

073.1

270

74,6

3,62

69,7

1

25

1

1

123

53

114,3

080.1

116

90,6

3,48

71,7

2

12,5

1

2

118

64

114,3

100.2

352

99,7

3,53

71,7

2

12,5

1

2

113

63

114,3

110.2

381

109

3,51

71,7

2

12,5

1

2

113

72

114,3

120.2

428

120

3,57

71,7

2

12,5

1

2

173

54

139,7

133.2

476

132

3,62

71,7

2

12,5

1

2

168

54

139,7

146.2

526

148

3,55

71,7

2

12,5

1

2

168

68

139,7

165.2Ecoplus SE ME/LR

400V / 3ph / 50Hz

McQuay Single Screw

Shell and Tube - Direct Expansion

Page 74: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

72

PFSWATER COOLED CHILLER WITH SCREW COMPRESSORS

STANDARD OPTIONS

Star-Delta startPhase monitorVictaulic water connections for evaporatorVictaulic water connections for condenser20 mm evaporator insulationManometersHour run meterGeneral fault relayAlarm from external device

GENERAL CHARACTERISTICS

Extra high efficiencyStepless capacity control Single-screw compressors; Star-Delta standard startShell and tube flooded evaporator; shell and tube plates made of carbon steel; high efficiency copper tubes; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantShell and tube condenser; shell and tube plates made of carbon steel; high efficiency copper tubes; Victaulic water connectionsMicro Tech II C Plus controller compatible with BMS

OPTIONS ON REQUEST

Soft starterCompressors thermal relaysVoltage controlAmmeter and voltmeterPower factor correctionFlanged water connections for evaporatorFlanged water connections for condenser20 mm condenser insulationCondenser with Cu-Ni 90-10 tubesEvaporator flow switchCondenser flow switchWater differential pressure switch for evaporatorWater differential pressure switch for condenserSuction line shut-off valvesRubber anti vibration mountsSoundproof cabinetEvaporator 3/4 Passes

Cooling capacity: 369 kW ÷ 1150 kW

WATER CO

OLED

CHILLERS

R-134aRefrigerant

FLDExchanger

shnti v

dproof aporator

su

0 tu

EST

nsulatiCu-Ni 90-10

ow switcflow switch

fferential pressure switcfferential pressure switch ne shu

vibration mountsc

3/4 Passes

suessur

off valvion m

s for evapfor conde

ub

for e

rase

de

poen

u-Ni 90-1w switch

ow switchrential pressure swirential pressure switc

ut-off valvesibration mou

cabinet4 Passes

sulatCu-Ni 90-1

ow switchflow switch

erential pressure switerential pressure switchne shut-off valves

vibration mountc/4 Passes

ssurressur

off valvetion m

ays

r

sys

for evaor cond

bes

or

for evafor cond

b

for

atorer

atser

eviceev e

oratornser

orns

Page 75: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA PFS

PFSWATER COOLED CHILLER WITH SCREW COMPRESSORS

73

WAT

ER C

OO

LED

CH

ILLE

RS

C

B

A

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

103.1

3340

3500

3625

1846

2250

124.1

3480

3700

3860

1846

2250

147.1

3603

3870

3860

1846

2250

208.2

5546

5911

4145

1743

2300

229.2

5636

6045

4145

1743

2300

249.2

6007

6460

4145

1808

2300

272.2

6448

6972

4145

1910

2300

296.2

6598

7163

4145

1910

2300

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

mm

V/ph/Hz

339,0

63,2

5,68

6,44

78,0

1

25

1

1

78

35

168,3

1

83

35

139,7

103.1

432

75,8

5,71

6,47

79,0

1

25

1

1

107

43

168,3

1

111

25

168,3

124.1

491

84,9

5,79

6,56

80,0

1

25

1

1

134

37

219,1

1

133

26

168,3

147.1

714,0

126,0

5,65

7,16

81,0

2

12,5

1

1

184

51

219,1

1

181

28

219,1

208.2

793

139

5,71

7,23

81,5

2

12,5

1

1

210

37

219,1

1

199

26

219,1

229.2

870

155

5,77

7,32

82,0

2

12,5

1

1

210

45

219,1

1

243

25

219,1

249.2

976,0

168

5,81

7,37

82,5

2

12,5

1

1

281

41

273,0

1

243

29

219,1

272.2

1050

180

5,83

7,40

83,0

2

12,5

1

1

302

34

273,0

1

263

27

219,1

296.2PFS

400V / 3ph / 50Hz

R-134a

1150

203

5,66

7,20

83,0

2

12,5

1

1

320

45

273,0

1

282

35

219,1

326.2

326.2

6702

7298

4145

1910

2300

McQuay Single Screw

Shell and Tube - Flooded

Shell and Tube

Page 76: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

74

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Single-screw compressors; Star-Delta standard startDirect expansion shell and tube evaporator with single pass; shell and tube plates made of carbon steel; high efficiency copper tubes; insulation made of closed cells material; Victaulic water connectionsR134a refrigerantShell and tube condensers; one per each circuit; shell and tube plates made of carbon steel; high efficiency copper tubes; GAS water connectionsMicro Tech II C Plus controller compatible with BMS

STANDARD OPTIONS

Star-Delta startDouble set pointPhase monitorEvaporator Victaulic kitManometersHour run meterGeneral fault relaySet-Point reset, demand limit and alarm from external deviceCondenser 1 pass (at 4-8°C) on SE unitsCondenser 2 passes (at 4-8°C) on XE unitsElectronic expansion valveDual pressure relief valve on condenser

Cooling capacity: 333 kW ÷ 1510 kW

OPTIONS ON REQUEST

Partial and total heat recoveryHeat pump versionBrine version Compressors thermal overload relaysUnder/overvoltage controlAmpere volt meterCondenser power factor correctionCurrent limit - display20 mm evaporator/condenser insulationCondenser Victaulic kitCu-Ni 90-10 exchangersCondenser 2 passes (at 9-15°C) on SE ST and 4 passes (at 9-15°C)on XE ST unitsEvaporator/condenser flow switchSuction line shut-off valvesDischarge line shut-off valvesRubber anti vibration mountsDual pressure relief valve on evaporatorSound proof cabinet

WATER CO

OLED

CHILLERS

R-134aRefrigerant

S&TExchanger

VERSIONS

SE Standard efficiency

XE High efficiency

SE ME CondenserlessSE LR Condenserless

with liquid receiver

NOISE LEVELSStandard noise

EER up to 4,66ESEER up to 5,75

EER up to 5,12ESEER up to 6,31

EER up to 3,91EER up to 3,91

75,2 ÷ 83,0 dB(A)

all

t

on S

NS

o 4,66R up to 5

up

mand lim

pass (at 4-8°C) or 2 passes (at 4-8°C) o

c expansionsure relief valve on cond

valvalve

t a ar

SE XE unit

fr ext

noise

ss E

75

EESE

upR u

ER up to 3R up to 3

OP

Pa

and

pass (at 4-8°C) 2 passes (at 4-8°C)

expansion valveure relief valve on con

mand l

pass (at 4-8°C) o2 passes (at 4-8°C)

expansionsure relief valve on con

valvf valve

and ala

E unitsXE un

a la

SE unitsXE uni

rom exfro ex

se 7

s

75

EES

EER uESEER

R up toup to

EES

R uESEER

ER up to R up to

O

P

O

P

Page 77: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA WHS E SE ST

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

75

WAT

ER C

OO

LED

CH

ILLE

RSaircool / McQuay reserves the right to make changes in design and construction at anytime without notice

C

B

A

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

333

71

4,66

5,06

75,2

1

25

1

1

193

37

168,3

1

37

26

5"

096.1

394

86

4,59

4,96

76,2

1

25

1

1

193

50

168,3

1

43

28

5"

112.1

460

101

4,56

4,93

78,2

1

25

1

1

183

54

168,3

1

48

30

5"

131.1

538

120

4,47

4,86

78,2

1

25

1

1

172

62

168,3

1

61

26

5"

153.1

640

141

4,53

5,54

77,8

2

12,5

2

1

271

55

168,3

2

74

25

5"

182.2

705

156

4,52

5,75

78,2

2

12,5

2

1

263

44

168,3

2

80

25

5"

200.2

782

171

4,57

5,56

78,7

2

12,5

2

1

256

58

168,3

2

86

28

5"

222.2

844

186

4,55

5,70

79,8

2

12,5

2

1

248

53

168,3

2

93

28

5"

240.2

910

200

4,55

5,47

80,7

2

12,5

2

1

241

53

168,3

2

100

26

5"

251.2WHS E SE ST

R-134a

400V / 3ph / 50Hz

986

218

4,51

5,61

80,7

2

12,5

2

1

233

66

168,3

2

117

23

5"

281.2

kg

kg

mm

mm

mm

2150

2380

3398

1430

1821

2160

2396

3398

1430

1821

2179

2410

3398

1430

1821

2224

2457

3398

1430

1821

3909

4217

4361

1350

2113

3927

4228

4361

1350

2113

3945

4243

4361

1350

2113

3971

4262

4361

1350

2113

3996

4288

4361

1350

2113

4080

4369

4361

1350

2113

096.1 112.1 131.1 153.1 182.2 200.2 222.2 240.2 251.2 281.2

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

McQuay Single Screw

Shell and Tube

Shell and Tube

Page 78: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

76

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

WATER CO

OLED

CHILLERS

TECHNICAL DATA WHS E SE ST

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

C

B

A

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

1027

237

4,33

5,36

80,7

2

12,5

2

1

233

51

168,3

2

122

24

5"

292.2

1155

254

4,54

5,51

80,4

3

8,3

3

1

504

52

219,1

3

135

24

5"

329.3

1204

268

4,50

5,56

80,8

3

8,3

3

1

504

56

219,1

3

143

24

5"

342.3

1274

282

4,51

5,56

81,2

3

8,3

3

1

489

47

219,1

3

151

25

5"

362.3

1346

298

4,51

5,54

83,0

3

8,3

3

1

472

58

219,1

3

159

24

5"

383.3

1401

316

4,43

5,55

83,0

3

8,3

3

1

472

62

219,1

3

167

24

5"

398.3

1455

335

4,35

5,45

83,0

3

8,3

3

1

472

66

219,1

3

174

24

5"

414.3

1510

353

4,28

5,27

83,0

3

8,3

3

1

472

71

219,1

3

183

23

5"

429.3WHS E SE ST

R-134a

400V / 3ph / 50Hz

kg

kg

mm

mm

mm

4092

4386

4361

1350

2113

292.2

6079

6628

4426

2435

2323

329.3

6097

6646

4426

2435

2323

342.3

6136

6670

4426

2135

2323

362.3

6174

6699

4426

2135

2323

383.3

6192

6717

4426

2135

2323

398.3

6210

6735

4426

2135

2323

414.3

6228

6761

4426

2135

2323

429.3

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

McQuay Single Screw

Shell and Tube

Shell and Tube

Page 79: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA WHS E XE ST

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

77

WAT

ER C

OO

LED

CH

ILLE

RSaircool / McQuay reserves the right to make changes in design and construction at anytime without notice

C

B

A

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

362

71

5,12

5,34

75,2

1

25

1

1

326

64

168,3

1

79

48

5"

096.1

433

85

5,08

5,27

76,2

1

25

1

1

317

48

168,3

1

94

47

5"

112.1

506

100

5,06

5,22

78,2

1

25

1

1

308

54

168,3

1

105

51

5"

131.1

573

120

4,76

5,11

78,2

1

25

1

1

308

68

168,3

1

105

66

5"

153.1

720

142

5,08

6,13

77,8

2

12,5

2

1

539

48

219,1

2

157

48

5"

182.2

795

156

5,10

6,31

78,2

2

12,5

2

1

539

48

219,1

2

173

48

5"

200.2

866

170

5,08

6,01

78,7

2

12,5

2

1

528

47

219,1

2

188

47

5"

222.2

933

185

5,05

6,14

79,8

2

12,5

2

1

528

50

219,1

2

199

50

5"

240.2

976

199

4,90

5,90

80,7

2

12,5

2

1

528

72

219,1

2

209

50

5"

251.2WHS E XE ST

R-134a

400V / 3ph / 50Hz

1038

220

4,72

6,05

80,7

2

12,5

2

1

504

46

219,1

2

209

65

5"

281.2

1134

240

4,73

5,67

80,7

2

12,5

2

1

504

52

219,1

2

209

65

5"

292.2

kg

kg

mm

mm

mm

2594

2998

4081

1430

1883

2667

3078

4081

1430

1883

2704

3116

4081

1430

1883

2704

3116

4081

1430

1883

4964

5582

4769

1350

2245

4997

5615

4769

1350

2245

5049

5671

4769

1350

2245

5073

5695

4769

1350

2245

5097

5729

4769

1350

2245

5132

5741

4769

1350

2245

096.1 112.1 131.1 153.1 182.2 200.2 222.2 240.2 251.2 281.2

5132

5741

4769

1350

2245

292.2

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

McQuay Single Screw

Shell and Tube

Shell and Tube

Page 80: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

78

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

WATER CO

OLED

CHILLERS

TECHNICAL DATA WHS E SE ME/LR

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

C

B

A

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 45°C saturated discharge temperature at the compressor(2) At 1m, according to ISO 3744, at free field semispherical conditions.

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

V/ph/Hz

328

83,8

3,91

75,2

1

25

1

1

193

34

168,3

096.1

391

100

3,90

76,2

1

25

1

1

193

47

168,3

112.1

428

116

3,70

78,2

1

25

1

1

183

47

168,3

131.1

504

137

3,67

78,2

1

25

1

1

172

54

168,3

153.1

596

165

3,61

77,8

2

12,5

2

1

271

49

168,3

182.2

657

181

3,63

78,2

2

12,5

2

1

263

39

168,3

200.2

730

198

3,69

78,7

2

12,5

2

1

256

52

168,3

222.2

788

214

3,67

79,8

2

12,5

2

1

248

47

168,3

240.2

850

231

3,67

80,7

2

12,5

2

1

241

47

168,3

251.2WHS E SE ME/LR

R-134a

400V / 3ph / 50Hz

919

252

3,65

80,7

2

12,5

2

1

233

45

168,3

281.2

kg

kg

mm

mm

mm

1861

2054

3114

1464

1899

1861

2054

3114

1464

1899

1869

2052

3114

1464

1899

1884

2056

3114

1464

1899

3331

3602

4391

1464

2325

3339

3602

4391

1464

2325

3347

3603

4391

1464

2325

3356

3604

4391

1464

2325

3364

3605

4391

1464

2325

3412

3645

4391

1464

2325

096.1 112.1 131.1 153.1 182.2 200.2 222.2 240.2 251.2 281.2Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

Cooling Capacity1

Unit Power Input1

EER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

McQuay Single Screw

Shell and Tube

Page 81: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA WHS E SE ME/LR

WHS EWATER COOLED CHILLER WITH SCREW COMPRESSORS

79

WAT

ER C

OO

LED

CH

ILLE

RS

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

C

B

A

kW

kW

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

V/ph/Hz

966

271

3,56

80,7

2

12,5

2

1

233

45

168,3

292.2

1033

279

359

80,1

3

8,3

3

1

521

52

219,1

305.3

1078

296

3,64

80,4

3

8,3

3

1

504

46

219,1

329.3

1125

312

3,60

80,8

3

8,3

3

1

504

49

219,1

342.3

1188

329

3,61

81,2

3

8,3

3

1

489

41

219,1

362.3

1267

347

3,65

83,0

3

8,3

3

1

472

51

219,1

383.3

1319

366

3,60

83,0

3

8,3

3

1

472

55

219,1

398.3

1370

386

3,55

83,0

3

8,3

3

1

472

59

219,1

414.3

1422

405

3,51

83,0

3

8,3

3

1

472

63

219,1

429.3WHS E SE ME/LR

R-134a

400V / 3ph / 50Hz

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 45°C saturated discharge temperature at the compressor(2) At 1m, according to ISO 3744, at free field semispherical conditions.

kg

kg

mm

mm

mm

3412

3645

4391

1464

2325

5146

5667

4426

2135

2415

5167

5671

4426

2135

2415

5167

5671

4426

2135

2415

5188

5677

4426

2135

2415

5208

5680

4426

2135

2415

5208

5680

4426

2135

2415

5208

5680

4426

2135

2415

5208

5680

4426

2135

2415

292.2 305.3 329.3 342.3 362.3 383.3 398.3 414.3 429.3

Cooling Capacity1

Unit Power Input1

EER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

McQuay Single Screw

Shell and Tube

Page 82: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

80

Proximus EvolutionWATER COOLED CHILLER WITH SCREW COMPRESSORS

Cooling capacity: 378 kW ÷ 2196 kW

WATER CO

OLED

CHILLERS

VERSIONS

EFFICIENCYSE Standard efficiency

XE High efficiency

NOISE LEVELSST Standard noise

GENERAL CHARACTERISTICS

Stepless capacity control Indipendent circuit for each compressor Single-screw compressors; Star-Delta standard startDirect expansion shell and tube evaporator with single pass; shell and tube plates made of carbon steel; high efficiency copper tubes; insulation made of closed cells material; Victaulic water connectionsR410A refrigerantShell and tube condensers; one per each circuit; shell and tube plates made of carbon steel; high efficiency copper tubes; GAS water connectionsMicro Tech II C Plus controller compatible with BMS

STANDARD OPTIONS

Star-Delta startDouble set pointPhase monitorVictaulic water connections for evaporatorGAS water connections for condensers10 mm evaporator insulationManometersHour run meterGeneral fault relayAlarm from external device

OPTIONS ON REQUEST

Partial heat recoverySoft starterBrine versionCompressors thermal relaysVoltage controlAmmeter and voltmeterPower factor correctionAbsorbed current limit / display20 mm evaporator insulation20 mm condensers insulationVictaulic water connections for condensersFlanged water connections for condensersCondenser with Cu-Ni 90-10 tubesEvaporator flow switchCondenser flow switchSuction line shut-off valvesDischarge line shut-off valvesRubber anti vibration mountsSoundproof cabinet

EER up to 4,64ESEER up to 5,37

EER up to 5,09ESEER up to 5,98

82,2 ÷ 87,9 dB(A)

R-410ARefrigerant

S&TExchanger

S

or evonde

R up to 4ER up tER u

layxte

evonden

on

poer

8

EEE

ERR u

2 ÷ 87,9

O

Pa

yternal device

ayxternal device

ions foor

ons ons fnde

nnde

on

oratorrs

pors

ESEEE

ESEER

÷ 87

SEEE

ER

2 ÷ 87,

OO

P

Page 83: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA Proximus Evolution SE

Proximus EvolutionWATER COOLED CHILLER WITH SCREW COMPRESSORS

81

WAT

ER C

OO

LED

CH

ILLE

RS

C

B

A

aircool / McQuay reserves the right to make changes in design and construction at anytime without noticeght t make change in design and conshe rigre rig

CC

ke changake change n design and con design and con

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

111.1 135.1 164.1 186.1 211.1 231.2 251.1 254.2 279.2 293.1

111.1 135.1 164.1 186.1 211.1 231.2 251.1 254.2 279.2 293.1

Proximus Evolution SE

R-410A

400V / 3ph / 50Hz

388

87

4,45

4,95

82,2

1

25

1

1

124

49

168,3

1

79

60

5”

474

106

4,47

4,98

83,0

1

25

1

1

118

65

168,3

1

92

64

5”

574

130

4,42

4,97

83,9

1

25

1

1

176

45

219,1

1

84

68

5”

652

148

4,41

4,97

83,9

1

25

1

1

170

48

219,1

1

126

66

5”

742

170

4,36

4,72

83,2

1

25

1

1

274

55

219,1

1

97

16

6”

813

175

4,65

5,37

84,0

2

25

2

1

344

54

219,1

2

79+79

64

5”

880

206

4,27

4,60

84,9

1

25

1

1

266

50

219,1

1

102

20

6”

891

194

4,59

5,36

85,2

2

12,5

2

1

344

64

219,1

2

79+92

67

5”

980

213

4,60

5,34

85,2

2

12,5

2

1

325

59

219,1

2

92+92

68

5”

1028

246

4,18

4,53

85,6

1

12,5

1

1

251

57

219,1

1

104

26

6”

1933

2135

3431

1065

1846

1967

2169

3431

1065

1846

2283

2543

3440

1226

2000

2332

2628

3440

1226

2000

2407

2777

3561

1226

1846

3921

4422

4902

1350

2170

2427

2795

3561

1266

1846

3949

4463

4902

1350

2170

3988

4496

4902

1350

2170

2457

2812

3561

1266

1846

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 84: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

82

Proximus EvolutionWATER COOLED CHILLER WITH SCREW COMPRESSORS

WATER CO

OLED

CHILLERS

TECHNICAL DATA Proximus Evolution SE

C

B

A

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

1077

237

4,54

5,33

86,0

2

12,5

1

1

325

70

219,1

2

52+60

70

6”

307.2

1210

262

4,62

5,36

86,5

2

12,5

1

1

538

46

273,0

2

60+60

73

6”

345.2

1281

279

4,59

5,35

86,9

2

12,5

1

1

538

51

273,0

2

60+68

73

6”

365.2

1352

296

4,57

5,29

86,9

2

12,5

1

1

538

56

273,0

2

68+68

70

6”

385.2

1488

340

4,38

4,93

86,2

2

12,5

1

1

505

60

273,0

2

55+55

17

6”

424.2

1620

375

4,32

4,93

86,6

2

12,5

1

1

505

70

273,0

2

55+57

19

6”

462.2

1783

409

4,36

4,82

87,0

2

12,5

1

1

495

90

273,0

2

61+61

17

6”

508.2

1928

442

4,36

4,89

87,5

2

12,5

1

1

539

99

273,0

2

61+77

17

6”

549.2

2093

476

4,40

4,87

87,9

2

12,5

1

1

527

123

273,0

2

77+77

15

6”

596.2

307.2 345.2 365.2 385.2 424.2 462.2 508.2 549.2 596.2

Proximus Evolution SE

R-410A

400V / 3ph / 50Hz

4344

4780

4912

1350

2379

4529

5186

4835

1350

2455

4536

5200

4835

1350

2455

4607

5280

4835

1350

2455

4988

5602

4844

1350

2547

4999

5615

4844

1350

2547

5053

5670

4844

1350

2547

5204

5881

4809

1350

2547

5289

5970

4809

1350

2547

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 85: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA Proximus Evolution XE

Proximus EvolutionWATER COOLED CHILLER WITH SCREW COMPRESSORS

83

WAT

ER C

OO

LED

CH

ILLE

RS

C

B

A

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

111.1 135.1 164.1 186.1 211.1 251.1 279.2 293.1 307.2

111.1 135.1 164.1 186.1 211.1 251.1 279.2 293.1 307.2

Proximus Evolution XE

R-410A

400V / 3ph / 50Hz

431

87

4,95

5,58

82,2

1

25

1

1

220

59

219,1

1

52

50

5”

527

105

5,02

5,61

83,0

1

25

1

1

213

73

219,1

1

69

40

5”

653

128

5,10

5,69

83,9

1

25

1

1

200

76

219,1

1

81

42

5”

740

146

5,07

5,67

83,9

1

25

1

1

334

68

219,1

1

86

47

5”

818

162

5,05

5,64

83,2

1

25

1

1

325

60

219,1

1

83

60

5”

993

197

5,04

5,39

84,0

1

25

1

1

538

57

273,0

1

91

65

5”

1060

210

5,05

5,89

85,6

2

12,5

2

1

587

57

273,0

2

69+70

40

5”

1139

232

4,91

5,28

84,9

1

25

1

1

538

73

273,0

1

91

84

5”

1182

233

5,07

5,87

86,0

2

12,5

2

1

575

67

273,0

2

73+76

48

5”

2322

2594

3987

1211

2000

2403

2685

3987

1211

2000

2464

2745

3937

1211

2000

2738

3158

3855

1218

2000

2407

2815

3855

1266

2000

2427

3056

3891

1448

2000

4775

5431

4985

1350

2453

2457

3086

3891

1448

2000

4831

5479

4985

1350

2453

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 86: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

84

Proximus EvolutionWATER COOLED CHILLER WITH SCREW COMPRESSORS

WATER CO

OLED

CHILLERS

TECHNICAL DATA Proximus Evolution XE

C

B

A

CC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) At 1m, according to ISO 3744, at free field semispherical conditions.

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

Cooling Capacity1

Unit Power Input1

EER

ESEER

Sound Pressure Level2

Compressor

Quantity

Minimum Capacity

Refrigerant

Circuits Number

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

--

--

dB(A)

Type

Nr

%

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

345.2 365.2 385.2 424.2 462.2 508.2 549.2 596.2

345.2 365.2 385.2 424.2 462.2 508.2 549.2 596.2

Proximus Evolution XE

R-410A

400V / 3ph / 50Hz

1298

258

5,03

5,88

86,5

2

12,5

2

1

563

58

273,0

2

76+76

50

5”

1397

275

5,08

5,98

86,9

2

12,5

2

1

551

71

273,0

2

75+86

48

5”

1479

292

5,07

5,93

86,9

2

12,5

2

1

551

79

273,0

2

86+86

48

5”

1605

322

4,98

5,67

86,2

2

12,5

2

1

495

74

273,0

2

91+91

45

5”

1769

356

4,97

5,71

86,6

2

12,5

2

1

484

94

273,0

2

91+91

65

5”

1901

390

4,87

5,48

87,0

2

12,5

2

1

535

96

273,0

2

91+91

63

5”

2061

426

4,84

5,50

87,5

2

12,5

2

1

527

119

273,0

2

92+92

83

5”

2196

461

4,76

5,38

87,9

2

12,5

2

1

527

134

273,0

2

92+92

82

5”

4873

5512

4985

1350

2453

4919

5546

4985

1350

2453

4969

5606

4985

1350

2547

5117

5794

4844

1350

2547

5117

5843

4844

1350

2547

5388

6110

4809

1350

2547

5408

6118

4809

1350

2547

5414

6124

4809

1350

2547

McQuay Single Screw

Shell and Tube - Direct Expansion

Shell and Tube

Page 87: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 88: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

86

WMCWATER COOLED CHILLERS -

WATER CO

OLED

CHILLERS

CENTRIFUGAL COMPRESSOR WITH MAGNETIC BEARINGS

Economy / EER, ESEERLike the best of the still unrivaled Centrifugal Series WSC and WDC units from McQuay, the magnetic bearing WMC series provide very good performance ratings in full and partial load ranges and ranks well in the McQuay family of chillers.

Magnetic Bearings

The two level impeller shaft is supported by a triple contact-free magnetic bearing. In the case of a power failure the electric motor acts as a generator and supplies the magnetic bearing with electricity until rotation stops. Therefore, oil for bearing lubrication is not needed.

Power ControlThe speed control of the compressor’s synchronous motor and an inlet guide vane provide for infinitely adjustable power control.

A HEAD START THROUGH INNOVATION

Reliability and efficiency have always distinguished McQuay chillers. McQuay as a technology leader was instrumental in the development of a centrifugal-compressor with magnetic bearings. The first chillers with Turbocor compressors carried the McQuay label. The first WMC units were installed in the U.S. as early as 2002. Starting in 2004, the WMC-centrifugals were released for unrestricted sales in the U.S. The consistent technology advances developed at McQuay were expanded and in 2008 led to the successful launch of the WMC series in the European market.

Control and RegulationA large 15 "touch screen mounted on a swivel arm constantly provides information about operating conditions and displays temperatures, pressures, pressure loss and flows. In addition, a trend report is available which can also be printed.

Cut view:Centrifugal compressor with magnetic bearings of a water cooled McQuay chiller

Page 89: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 90: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WMCWATER COOLED CHILLERS -CENTRIFUGAL COMPRESSOR WITH MAGNETIC BEARINGS

Cooling capacity: 313 kW ÷ 1050 kW

VERSIONS

WMC

NOISE LEVELSStandard noise

GENERAL CHARACTERISTICS

Oil free Centrifugal Compressor with magnetic bearingsHermetically-Sealed, Direct Drive MotorUnit Mounted VFDVFP location: integral to compressorRefrigerant-Cooled VFD & MotorNon-Powered Coast Down using Regenerative Power System and Backup BearingsTouchscreen InterfaceR-134a refrigerant

STANDARD OPTIONS

Inverter compressor starterEvaporator victaulic kitEvaporator waterside design pressure 10 bar20 mm evaporator insulationCondenser victaulic kitCondenser water side design pressure 16 barElectronic expansion valveHour run meterGeneral fault contactor

OPTIONS ON REQUEST

Evaporator flauge kitCondenser flauge kitCondenser double flange kitEvaporator water side design pressure 25 barCondenser water side design pressure 25 bar20 mm condenser insulationWater pressure differential switch on evaporatorWater pressure differential switch on condenserEvaporator flow switchCondenser flow switchDischarge line shut off valveSuction line shut off valveHigh pressure side manometersAnti vibration mountsDouble set pointCompressor thermal relaisAmpere volt meterCurrent limit displaySet point reset, demand limit and alarm from external device

EER up to 5,30ESEER up to 9,30

81,1 ÷ 83,1 dB(A)

R-134aRefrigerant

FLDExchanger

Inverter

OIL FREE

88

WATER CO

OLED

CHILLERS

Page 91: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WMCWATER COOLED CHILLERS -

TECHNICAL DATA WMC

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

CENTRIFUGAL COMPRESSOR WITH MAGNETIC BEARINGS

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kW

-

-

dB(A)

Type

No.

Type

Type

No.

Type

kPa

mm

Type

kPa

mm

V/ph/Hz

114÷317

5,40

8,60

81,1

1

R-134a

1

30

168,3

24

168,3

Frictionless Centrifugal Compressor with Magnetic Bearings

Variable Speed Centrifugal Compressor

Shell&Tube - Flooded

Shell&Tube - Flooded

400 V / 3ph / 50 Hz

100S

128÷429

5,40

8,60

80,8

1

R-134a

1

31

168,3

25

168,3

125S

172÷521

6,00

9,40

80,6

1

R-134a

1

23

219,1

28

168,3

150S

114÷635

5,40

8,80

83,1

2

R-134a

1

18

219,1

24

219,1

200D

128÷856

5,50

8,60

82,8

2

R-134a

1

21

219,1

25

219,1

250D

172÷1048

5,90

9,60

82,6

2

R-134a

1

11

273

29

219,1

300DWMC

kg

kg

mm

mm

mm

2360

2520

3254

1491

1639

100S

2416

2634

3254

1491

1639

125S

2546

2812

3254

1491

1639

150S

3709

4074

3419

1745

1729

200D

4095

4548

3289

1854

1748

250D

4765

5330

3289

1904

1726

300D

Cooling Capacity (MIN÷MAX) 1-2

EER up to 3

ESEER up to 4

Sound Pressure Levels 5

Compressor

Quantity

Capacity Control

Refrigerant

N. of circuits

Evaporator

Pressure drop 6

Water Connections Size

Condenser

Pressure drop 6

Water Connections Size

Standard Voltage

C

A B

SELECTION SOFTWARE: Since a Frictionless Centrifugal Chiller, at fixed evaporator and condenser water conditions, can provide different Cooling Capacity, EER, sound level, etc depending on the speed of rotation, a dedicated selection tool is availbale to make unit selections and calculate the Performance Data (EER and Part load data) in specific working conditions.

NOTES:(1) Indicated intervals are related to full load Cooling Capacity at standard conditions: 12/7°C evaporator water temperature and 30/35°C condenser water temperature(2) For dual compressor units the minimum capacity is related to the conditions with only one compressor running(3) Indicated EER is the maximum at standard conditions (see also note 1)(4) Indicated ESEER is the maximum with full load at standard conditions (see also note 1)(5) Sound pressure related to maximum Cooling Capacity at standard conditions, according to ISO 3744 at 1m and free field semispherical conditions(6) Pressure drop values are related to maximum Cooling Capacity at standard conditions 89

WAT

ER C

OO

LED

CH

ILLE

RS

Page 92: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WME (coming soon!)WATER COOLED CHILLERS -CENTRIFUGAL COMPRESSOR WITH MAGNETIC BEARINGS

WME - MagnitudeThe newest member of the McQuay Magnitude™ Chiller family (Model WME) takes Frictionless Centrifugal Chillers to a new level. Building on the outstanding success of Magnitude model WMC, the newest frictionless centrifugal chiller capitalizes on our 50 years of experience designing and manufacturing centrifugal compressor chillers.

Characteristics:- State-of-the-art magnetic bearing compressor- Unit-mounted Variable Frequency Drive- Positive pressure design-Extremely low vibrations levels- Hermetically sealed direct-drive motor- User-friendly MicroTech™ controls- R-134a refrigerant- AHRI certification

Benefit Summary:- Lowest Energy Consumption due to highest full and part load in its range- Low operation and maintenance costs- VFD provides at method of reducing the motor starting inrush current and reduces power input at the part load operation. An additional benefit of a VFD is improved power factors- Positive pressure, oil-free design eliminates performance degradation due to non-condensables - Increased Reliability- R-134a refrigerant (Zero Ozone Depletion Potential)- smart controlls and quiet

Technology:Cutting-edge magnetic bearing technology enables outstanding energy efficiency and reliable, long-life frictionless operation. The Magnitude chiller’s exceptional efficiency is due to the direct drive magnetic bearing compressor technology. This design eliminates the friction inherent in traditional centrifugal compressors that can reduce efficiency. A digitally-controlled magnetic bearing system replaces conventional lubricated bearings. The direct drive motor eliminates the need for a lubricated gear box and associated power losses. The frictionless compressor shaft is the compressor’s only moving component, and it levitates on a magnetic cushion. Sensors at each magnetic bearing provide real-time feedback to the bearing control system.

Figure 2: Compressor Rotating Assembly

Figure 1: WME cutview

d for a lubricated gear box and frictionless compressor shaft iscomponent, and it levitates s at

the be

rush ation. An

rsrmance

nt

re 2: Compres

paed pow

minates ples

on Potent

ises o

beaste

e 2: Compre

d pominates

es

on Poten

s onbearing

tem.

90

WATER CO

OLED

CHILLERS

Page 93: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA WME

WME (coming soon!)WATER COOLED CHILLERS -

91

WAT

ER C

OO

LED

CH

ILLE

RS

CENTRIFUGAL COMPRESSOR WITH MAGNETIC BEARINGS

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

400 V / 3ph / 50 Hz

1400÷2000

6,5

10,3

79

1

R-134a

1

38

250

34

300

500SWME

kg

kg

mm

mm

mm

7635

9285

4250

1950

2400

500S

C

B

A

right

kg

kg

mm

mm

mm

ght o make ch esign

76

92

25

0

0S

the hthe h make cmake ch

7

4

1950

2400

500

7

9

42

50

00S

coming soon!comingcocominging soon!

ing sooon!!!

coming soon!coming scom gming ssoon!g soon!n!

kW

-

-

dB(A)

Type

No.

Type

Type

No.

Type

kPa

mm

Type

kPa

mm

V/ph/Hz

Frictionless Centrifugal Compressor with Magnetic Bearings

Variable Speed Centrifugal Compressor

Shell&Tube - Flooded

Shell&Tube - Flooded

Cooling Capacity (MIN÷MAX) 1-2

EER up to 3

ESEER up to 4

Sound Pressure Levels 5

Compressor

Quantity

Capacity Control

Refrigerant

N. of circuits

Evaporator

Pressure drop 6

Water Connections Size

Condenser

Pressure drop 6

Water Connections Size

Standard Voltage

SELECTION SOFTWARE: Since a Frictionless Centrifugal Chiller, at fixed evaporator and condenser water conditions, can provide different Cooling Capacity, EER, sound level, etc depending on the speed of rotation, a dedicated selection tool is availbale to make unit selections and calculate the Performance Data (EER and Part load data) in specific working conditions.

NOTES:(1) Indicated intervals are related to full load Cooling Capacity at standard conditions: 12/7°C evaporator water temperature and 30/35°C condenser water temperature(2) For dual compressor units the minimum capacity is related to the conditions with only one compressor running(3) Indicated EER is the maximum at standard conditions (see also note 1)(4) Indicated ESEER is the maximum with full load at standard conditions (see also note 1)(5) Sound pressure related to maximum Cooling Capacity at standard conditions, according to ISO 3744 at 1m and free field semispherical conditions(6) Pressure drop values are related to maximum Cooling Capacity at standard conditions

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

Page 94: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

POWER LOSSDAMAGE PROTECTION

Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The compressors are equipped with a lubricant reservoir and a piston with a compressed spring that provides pressurized lubricant to the bearings during the coast-down period. Also, the compressors decelerate quickly due to the low inertia.

Moveable diffuser closing off impeller discharge area

Piston

Lubrificant reservoir

92

WSC - WDCWATER COOLED CHILLERS WITH CENTRIFUGAL COMPRESSORS

WATER CO

OLED

CHILLERS

UNMATCHED UNLOADING

Unloading to 10% of full load for a WSC single compressor chiller and 5% for a WDC dual compressor unit, without using inefficient hot gas bypass. This unloading capability provides improved stability of the chilled water temperature and less harmful cycling of compressors.Movable discharge diffuser increases stability and reduces vibrations.

VARIABLE FREQUENCYDRIVE OPTION

Improves part load efficiency.Reduces annual energy costs.

HIGH EFFICIENCY

• Full load - COP up to 7• Partial loads - COP up to 12 (with inverter)

REFRIGERANTSTORAGE CAPABILITY

The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate this charge. This feature eliminates the need for separate storage vessels in most applications.

WIDE CHOICE OF CAPACITIES AND EFFICIENCIES

Single compressorWSC: 300 kW ÷ 4500 kW - Approximately 1,1 million possible chiller offerings with combination options of motors, impellers, gears and vessels.Dual compressorWDC: 600 kW ÷ 9000 kW - Approximately 0,75 million possible chiller offerings with combination options of motors, impellers, gears and vessels.

QUIET OPERATION

Liquid InjectionA small amount of liquid refrigerant is taken from the condenser and injected into the compressor discharge area. The liquid droplets absorb sound energy and reduce the compressor’s overall sound level. The droplets evaporate and reduce discharge superheat.Quieter as chiller unloads McQuay’s design results in a reduction in sound levels at lower loads, where most chillers spend most of their operating hours.

denerant c

ves to isoneed for

AB

quipped with a lubricanta compressed spring that

t to the co.

s

e ssor

ss. This lity of th

ul cyclin

ed are

nsch

late this charate sto

YER

AGANT

E CA

are s

BAB

Pisto

Lubrificant

C dhot gaproved stss harmfu

ases stab

t the

er

Mo

sers are sizeharge and aate this c

t

ERANGE CAPABILITY

zed ar

sehate this ch

ate sto

TYERANTGE CAP

are s

BPAB

ton

ubrifican

ston

ubrifican

t groved

harm

es sta

ot gaproved s

s harmf

ses sta

he rate

M

he era

M

Page 95: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WSC - WDCWATER COOLED CHILLERS WITH CENTRIFUGAL COMPRESSORS

93

WAT

ER C

OO

LED

CH

ILLE

RS

PART LOAD EFFICIENCY

When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs to the dual compressor chiller produces an astonishing ARI certified IPLV.

PARTIAL LOADS EFFICIENCY FOR 2000 KW CENTRIFUGAL UNIT

ONE WDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR CHILLERS

• Lower equipment costs than two separate chillers• Lower installation cost than two separate chillers• Lower annual operating cost than either one large or two small chillers• Less equipment room space required than for two separate chillers• Capacity reduction to 5% of design value• Standby redundancy for most of the cooling seasonoptions of motors, impellers, gears and vessels. THE REDUNDANCY FEATURE

McQuay dual centrifugal chillers have two of everything, connected to a common evaporator and condenser - two compressors, two lubrication systems, two control systems, two starters. If any component on a compressor system fails, the component can be removed or repaired without shutting down the other compressor; providing an automatic back-up with at least 60 percent of the chiller design capacity available. In the unlikely event of a motor burnout, the chiller refrigerant charge will not be contaminated.

0,0

1,0

2,0

3,0

4,0

5,0

6,0

7,0

8,0

9,0

10,0

WSC WDC WSC-VFD WDC-VFD

7,0 7,4 9,7 10,0

IPLV

WCS: single compressorWDC: double compressorVFD: compressor inverterSpecific selections can vary up or down from this example.

0,0

ssorpaired

providinrcent of

ely evee w

,0

0

WS

07

N

remocompresast 60 pe

he unliket charge w

0

W

7,00

W

07

ITNI

emomprest 60 p

e unlikcharge

remocompreast 60 p

he unlike charge

Page 96: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

94

WSCWATER COOLED CHILLER WITH SINGLE CENTRIFUGAL COMPRESSOR

OPTIONS ON REQUEST

Start-/ Frequency drive via:- Soft starter- Frequency drive- Star-/ Delta StartMarine water box(es) provides an easy tube accesFlange and mating flange on the evaporator and condenserVictaulic connectionsThickness of heatexchanger tubing from 0,64 bis 0,89 mmWorking pressure of the vessels from 10 to 20 bar (10 bar standard)Flow protectionEvaporator insulation between 13mm and 38 mm. (13mm Standard)Compressor motor starter as separate stand alone unit of factory mountedModem for the transmission of all machine datas for monitoringMonitor software for the transmission of all machine datas to a PCExport packaging in container (standard in plastic wrap)Refrigerant pump out unit including tank for the storeage of the complete refrigerant chargeRefrigerant leak monitoring systemSound reduction kitWitness test of the machine on the test stand in the manufacturing facility

GENERAL CHARACTERISTICS

Cooling capacity up to 4550 kW, per unit.Steppless capacity control from 10-100% without hot gas bypass.Extra high efficiencyOperating power optimizied.Semi-hermetic; centrifugal compressorFlooded, shell and tube evaporatorShell and tube condenserThermostatic expansion- and pilot valveControl box with main power switchSafe refrigerant R134a ozone friendlyVariable speed pumpingHydraulic driven discharge diffuserPower loss damage protectionUnit controller and operator interface touch screenEasy to integrate into your building automation system such as BACnet, Modbus, LON, TCP/IP und web.Extensive optional equipment available

Cooling capacity: 560 kW ÷ 4550 kW

WATER CO

OLED

CHILLERS

R-134aRefrigerant

FLDExchanger

Inverter

Mto

t available

arate

all

r the transmission osoftw

sy tvapor

or insulaard)

mpressor motor sct

Modem for the tranmMonitor software foro xport packaging

rigerant pu

mountm for thor

r softwa

on the evap

anger tubing fromf the vessels from 10

on between 13mm

tarter as separ

tubivessels f

ween 13

y tube accrator and

0,64 bis 0,o 20 ba

of e

SoW

d)pressor motor

tory mountedodem for the traonitoonitor software foa PCport packagin

gerant p

r insurd)

mpressor motor cto

Modem for the tramMonitor software foo a

port packagingigerant pu

mountem for thoor softwa

the ev

nger tubing fromthe vessels from 1

n between 13mm

rter as sep

n the eva

anger tubing fromthe vessels from 10

n between 13mm

arter as sepa

r tubinvessels fr

ween 13

ube acator an

64 bis 020

tube accrator and

64 bis 0o 20 b

oRS

ofReSoW

Page 97: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WSCWATER COOLED CHILLER WITH SINGLE CENTRIFUGAL COMPRESSOR

NOTES:(1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) Running Current at 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(3) At 5m, according to ISO 3744, at free field semispherical conditions.(4) A Higher COP-value can be realized through larger heat exchanger surface.(*) Example selection

95

WAT

ER C

OO

LED

CH

ILLE

RS

C

B

A

TECHNICAL DATA WSC - cooling only

Range of Capacity1

* Cooling Capacity 1

Unit Power Input 1

Running Amperes 2

COP4

Stepless Capacity Control

Sound Pressure Level3

Compressor

Quantity

Refrigerant

Circuits Number

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

kW

A

--

%

dB(A)

Type

Nr

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

063

560 - 1.050

850

135,6

235

6,37

10 - 100

73

1

1

1

419

18,3

203,2

1

336

31,7

254

WSC

1.050 - 1.800

1.150

179,8

304

6,40

10 - 100

75

1

1

1

545

17,8

254

1

574

11,7

304,8

079

1.050 - 2.110

1.700

256,0

427

6,64

10 - 100

76

McQuay Centrifugal

1

R134a

1

1

884

15,8

304,8

1

841

18,3

355,6

087

2.100 - 3.100

2.600

387,0

633

6,72

10 - 100

77

1

1

1

1302

17,0

355,6

1

1237

23,4

457,2

100

2.100 - 3.800

3.260

493,9

803

6,60

10 - 100

75

1

1

1

1855

15,5

457,2

1

1237

36,0

457,2

113

Shell and Tube

Shell and Tube - Flooded

400V / 3ph / 50Hz

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

063

5848

6462

4445

1346

2286

079

8319

9438

4445

1880

2388

087

12001

13726

4445

2184

2515

113

15883

18968

4597

2642

2692

15883

18968

4597

2642

2692

126100

14526

17066

4597

2489

2692

2.800 - 4.550

4.000

623,1

1050

6,42

10 - 100

78

1

1

1

1855

22,1

457,2

1

1237

50,4

457,2

126

NOTES:Weight and dimensions refer to the example selectionmple se

7,2

1

e s

6

2286

ect

087

er t erat

23

0

9

43

44

0

1

mm

e exam

m

ex

m

e exa tion

2286

cti

787

temper te per

1

7

1

37

079

831

9

44

188

2388

319

94

44

80

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 98: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

96

WDCWATER COOLED CHILLER WITH DUAL CENTRIFUGAL COMPRESSOR

OPTIONS ON REQUEST

Start-/ Frequency drive via:- Soft starter- Frequency drive- Star-/ Delta StartMarine water box(es) provides an easy tube accesFlange and mating flange on the evaporator and condenserVictaulic connectionsThickness of heatexchanger tubing from 0,64 bis 0,89 mmWorking pressure of the vessels from 10 to 20 bar (10 bar standard)Flow protectionEvaporator insulation between 13mm and 38 mm. (13mm Standard)Compressor motor starter as separate stand alone unit of factory mountedModem for the transmission of all machine datas for monitoringMonitor software for the transmission of all machine datas to a PCExport packaging in container (standard in plastic wrap)Refrigerant pump out unit including tank for the storeage of the complete refrigerant chargeRefrigerant leak monitoring systemSound reduction kitWitness test of the machine on the test stand in the manufacturing facility

GENERAL CHARACTERISTICS

Cooling capacity up to 9485 kW, per unit.Back-up with at least 60% of the chiller design capacity.Steppless capacity control from 5-100%.High efficiency, partial loads - COP up to 12.Less equipment room space for huge cooling capacity.Operating power optimizied.Semi-hermetic; centrifugal compressorFlooded, shell and tube evaporatorShell and tube condenserThermostatic expansion- and pilot valveControl box with main power switchSafe refrigerant R134a ozone friendlyVariable speed pumpingHydraulic driven discharge diffuserPower loss damage protectionUnit controller and operator interface touch screenEasy to integrate into your building automation system such as BACnet, Modbus, LON, TCP/IP und web.Extensive optional equipment available

Cooling capacity: 1120 kW ÷ 9485 kW

WATER CO

OLED

CHILLERS

R-134aRefrigerant

FLDExchanger

Inverter

Mto

, TCP/IP und web.t available

arate

all

r the transmission osoftw

sy tvapor

or insulaard)

mpressor motor scto

Modem for the tranmMonitor software foro xport packaging

rigerant pu

mountm for thor

r softwa

on the evap

anger tubing fromthe vessels from 10

on between 13mm a

tarter as separ

tubiessels fr

ween 13

tube accrator and

0,64 bis 0,8o 20 ba

of e

SoW

d)pressor motor

tory mountedodem for the traonitoonitor software foa PCport packagin

gerant p

insurd)

mpressor motor ctoodem for the tra

moMonitor software foo a

port packaginggerant pu

mountem for theoor softwar

the eva

nger tubing fromhe vessels from 1

n between 13mm

rter as sep

n the eva

anger tubing fromthe vessels from 10

n between 13mm

arter as sepa

tubinvessels fro

ween 13

ube acator an

64 bis 020

tube accator and

64 bis 0 20 b

oRS

ofReSoW

Page 99: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

WDCWATER COOLED CHILLER WITH DUAL CENTRIFUGAL COMPRESSOR

97

WAT

ER C

OO

LED

CH

ILLE

RS

C

B

A

TECHNICAL DATA WDC - cooling only

Range of Capacity1

* Cooling Capacity 1

Unit Power Input 1

Running Amperes 2

COP4

Stepless Capacity Control

Sound Pressure Level3

Compressor

Quantity

Refrigerant

Circuits Number

Condenser

Quantity

Water Volume

Pressure Drop

Water Connections Size

Evaporator

Quantity

Water Volume

Pressure Drop

Water Connections Size

Standard Voltage

kW

kW

kW

A

--

%

dB(A)

Type

Nr

Type

Nr

Type

Nr

l

kPa

mm

Type

Nr

l

kPa

--

V/ph/Hz

063

1.120 - 2.100

1.600

257,4

223

6,22

5 - 100

75

2

1

1

1251

16,2

304,8

1

918

24,2

304,8

WDC

1.500 - 2.800

2.400

374,7

335

6,41

5 - 100

77

2

1

1

1797

17,2

355,6

1

1313

19,1

355,6

079

1.800 - 4.420

3.400

515,5

429

6,60

5 - 100

79

McQuay Centrifugal

2

R134a

1

1

1797

25,0

355,6

1

1313

35,6

355,6

087

4.200 - 5.950

5.000

743,8

605

6,72

5- 100

80

2

1

1

3265

37,6

457,2

1

2503

54,4

457,2

100

4.900 - 6.700

6.500

1011,3

821

6,43

5 - 100

79

2

1

1

3265

66,8

457,2

1

2503

87,1

457,2

113

Shell and Tube

Shell and Tube - Flooded

400V / 3ph / 50Hz

5.600 - 9.485

8.400

1343,2

1129

6,25

5 - 100

78

2

1

1

3265

104,8

457,2

1

2503

137,6

457,2

126

NOTES:(1) 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(2) Running Current at 12/7°C entering/leaving evaporator water temperature; 30/35°C entering/leaving condenser water temperature.(3) At 5m, according to ISO 3744, at free field semispherical conditions.(4) A Higher COP - value can be realized through larger heat exchanger surface(*) Example selection

Weight and dimensions

Shipping weight

Operating weight

(A) Length

(B) Width

(C) Height

kg

kg

mm

mm

mm

063

12604

14082

5685

1896

2686

079

20189

23364

5698

2343

2530

087

20189

23364

5698

2343

2530

113

29921

35243

7010

2648

2810

29921

35243

7010

2648

2810

126100

29921

35243

7010

2648

2810

NOTES:Weight and dimensions refer to the example selection

063 079 0

e selec

113

29921921

,2

57,2

1

64

0

01

0

299

ter per

2

50

1

89

233

56

34

5

ample mpmple

87

89

100

28

4

08

18

00

29

r temper t pe

1

3

1

03

364

5698

2343

2530

2

2

336

5

3

0

23

25

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Page 100: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

A GLOBAL LEADER INSYSTEM SOLUTIONSFOR AIR CONDITIONING,HEATING, VENTILATINGAND REFRIGERATION

Page 101: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

FAN

CO

ILS

FAN COILS99

Page 102: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

FAN CO

ILS

100

MF - VERTICALFAN COILS

Cooling capacity: 1,2 kW ÷ 8,3 kWHeating capacity: 2,2 kW ÷ 13,0 kW

OPTION ON REQUEST

ControlsThe AC2800A electronic controller (optional) allows the regulation of all unit functions and operating modes, and is compatible for connection into a network for Master & Slave configuration for up to 16 units.Through the AC2800A units can also be directly integrated with Smart Manager, McQuay solution for the centralised control of the hydronic systems. With reference to Fan Coils, Smart Manager can control and monitor up to 256 units and 120 zones.

Electronic thermostat for wall mounted installation (AC8000; AC8000-NIM):DISPLAY LCD: • easy to operate full graphical user interface • allows an easy reading of the operating and auto-diagnosis parametersKEYBOARD allows to set parameters as follows:• set point temperature • fan speed selection • operating mode summer/winter • on/off • timer with 2 daily setting (14 weekly)• NIM connection (AC8000-NIM)REMOTE CONTROL AC5300:• infra-red control, allowing unit settings to be made remotely

Mechanical thermostat (AC512-2 pipes; AC513-4 pipes)• ambient temperature, fan speed, on/off

Valves kit (standard condensate drain pan), 2 or 3 ways

Feet (cover and/or support)

GENERAL CHARACTERISTICS

The series features 8 sizes, with cabinet for floor or wall installation and chassis for concealed installations. The units are available in the 2-pipe version with 3 or 4-row coil or in the 4-pipe version with 3+1 row coil.Cover, grids and cabinet materials have been selected with a special care to grant both the quality of the finishing and the durability of the product. Cover and grills are manufactured in ABS, RAL103; the cabinet is made of pre-painted sheet metal finished with high quality paint, RAL1013.The filter, located at the bottom of the unit, is easily accessible and self-locking, therefore no tools are required for removing and re-assembling it. The filter material grade is G1 and thanks to its pleated surface grants a filtration surface up to 60% greater than traditional filters resulting in lower pressure drop and reduced noise emission.Units are available with left or right hand water connections, which can be easily switched in the field if required. Connections are equipped with air vents and drainage valves.

STANDARD OPTION

The AC2800B electronic controller (standard for unit with cabinet) allows the regulation of all unit functions and operating modes

H2O

aKE

asily switched in the field if quipped with air vents and

N

ou

interthe

to set parameters as fognosisRD al

an aua

allows tg mode

for

ontroller ation of a

tandard founit func

onic therm8000; AC8000-NIM

SPeasy to operate full g

allows an easy auto-diagnosis paramKEYBOARD allows to

set point temperan speed selec

ating m

LCD: o operat

ws an eagnosis RD allo

nits cananager, McQua

of the hydronic ls, Smart Manager c

ni

os mouM):

art Mand 120 zo

r (optionaoperatingnetwork fo

also be y solution

systems. n contro

• oponti

• N

TIONONTION

trolleon of

ntrollertion of a

ndard nit fun

andard funit fun

ic therm00; AC8000-N

PLAY LCD: asy to operate full allows an easy

uto-diagnosis paraYBOARD allows tet point tempe

speed sel

nic therm000; AC8000-NI

PLeasy to operate full g

allows an easy uto-diagnosis paramEYBOARD allows toet point tempern speed sele

Y LCD: to operatews an eiagnosis pARD allo

ts canager, McQu

f the hydroni, Smart Manager

its and 120 zones.

tat for wall m

nits cannager, McQu

of the hydronics, Smart Manager

nit

st mo):

e hmart Mannd 120 zon

or wa

(optioperatinetwork

so besolutio

ystemscon

(optionperatingetwork f

also be solutionsystemsn cont

• o•

• oo t

Page 103: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

FAN

CO

ILS

TECHNICAL DATA MF - VERTICAL - fan coils

MF - VERTICALFAN COIL

101

B

C

A

B

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

MF

NOTES: (1) At the following nominal conditions: nominal air flow; 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; High speed(2) At the following nominal conditions: nominal air flow 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; High speed(3) At High/Medium/Low speed; nominal air flow; measured in a room of 100 m3 volume and 0.5 sec. reverberation time (e.g. office/conference room with carpet on the floor)(4) At the following nominal conditions: nominal air flow 70/60°C inlet/outlet water temperature; 20°C inlet air temperature; same water flow as for cooling; High speed(5) High speed

Nominal Air Flow (High/Medium/Low)

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input5

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

V/ph/Hz

inches

mm

012 CMF - 2 PIPE SYSTEM / 3 - ROW COIL

380/296/210

1,80

1,50

2,70

0,085

5

42/37/32

0,044

3/4”

20

497/349/260

2,70

1,90

3,60

0,129

10

42/35/32

0,044

3/4”

20

290/245/197

1,30

1,00

2,20

0,063

4

38/35/33

0,024

3/4”

20

020 C 025 C

705/565/400

3,60

2,60

4,80

0,170

16

48/44/39

0,059

3/4”

20

035 C

853/695/465

4,80

3,60

6,20

0,227

28

47/39/31

0,068

3/4”

20

050 C

1141/969/705

5,90

4,60

8,10

0,282

33

53/48/41

0,102

3/4”

20

060 C

1500/1368/1190

8,00

5,80

12,00

0,347

20

53/51/47

0,167

3/4”

20

090 C

1360/1063/824

6,90

5,30

10,50

0,358

18

51/47/40

0,147

3/4”

20

080 C

Weight and dimensions

Weight 2Pipe - 3Row

Weight with cabinet 2Pipe - 3Row

Weight 2&4Pipe - 4Row

Weight with cabinet 2&4Pipe - 4Row

Dimens. unit (A x B x C)

Dimension with cabinet (A x B x C)

kg

kg

kg

kg

mm

mm

20

22

24

26

704 x 224 x 540

910 x 230 x 539

24

29

28

31

904 x 224 x 540

1110 x 230 x 539

26

32

30

35

1104 x 224 x 540

1310 x 230 x 539

35

45

35

45

1304 x 224 x 540

1510 x 230 x 539

012 / 412 025 / 425 050 / 450 080 / 480020 / 420 035 / 435 060 / 460 090 / 490

220-240/1/50

MF

Nominal Air Flow (High/Medium/Low)

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input5

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

V/ph/Hz

inches

mm

412 CMF - 2 PIPE SYSTEM / 4 - ROW COIL

369/321/240

2,70

1,70

2,80

0,098

5

42/37/32

0,050

3/4”

20

445/330/250

3,10

2,10

4,20

0,149

10

41/34/32

0,051

3/4”

20

254/215/176

1,50

1,10

2,30

0,073

4

38/36/33

0,021

3/4”

20

420 C 425 C

677/545/380

4,60

2,80

5,30

0,193

14

47/43/38

0,056

3/4”

20

435 C

811/663/456

5,30

3,70

6,80

0,251

21

47/39/31

0,077

3/4”

20

450 C

1068/915/672

6,40

5,00

8,40

0,304

20

53/48/41

0,107

3/4”

20

460 C

1450/1288/1120

8,30

5,80

12,5

0,409

17

53/50/47

0,167

3/4”

20

490 C

1300/1165/908

7,10

5,50

11,0

0,397

18

51/47/40

0,143

3/4”

20

480 C

220-240/1/50

MF

Nominal Air Flow (High/Medium/Low)

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity4

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input5

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

V/ph/Hz

inches

mm

MF - 4 PIPE

369/321/240

1,80

1,40

2,90

0,084

5

42/37/32

0,050

3/4”

20

445/330/250

2,50

1,70

4,30

0,118

8

41/34/32

0,051

3/4”

20

254/215/176

1,20

0,90

2,30

0,057

4

38/36/33

0,021

3/4”

20

677/545/380

3,50

2,50

5,60

0,165

15

47/43/38

0,056

3/4”

20

811/663/456

4,60

3,40

7,00

0,219

26

47/39/31

0,077

3/4”

20

1068/915/672

5,70

4,40

8,60

0,271

16

53/48/41

0,107

3/4”

20

1450/1248/1078

8,00

5,20

13,0

0,345

17

53/50/47

0,161

3/4”

20

1300/1165/824

6,90

4,90

12,0

0,320

15

51/47/40

0,140

3/4”

20

220-240/1/50

012 H 020 H 025 H 035 H 050 H 060 H 090 H080 H

Page 104: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

102

MCK - CassetteFAN COILS

FAN CO

ILS

Cooling capacity: 2,64 kW ÷ 10,8 kWHeating capacity: 3,42 kW ÷ 13,8 kW

H2O

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

TECHNICAL DATA MCK - Cassette

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed(3) Sound pressure levels are tested at 1.4m below the centre of the unit (according to JIS C 9612 standard)(4) High speed

Nominal Air Flow

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

mm

662/630/594

2,64

2,05

3,42

0,111

67,3

44/43/42

0,056

0,22

3/4”

19

010CWMCK

662/630/594

4,40

3,22

5,48

0,195

68,6

44/42/41

0,075

0,30

3/4”

19

015CW

731/695/662

4,44

3,52

5,73

0,203

46,6

47/46/44

0,074

0,34

3/4”

19

020CW

Shipping weight (unit + panel)

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

22+2

570

570

250

010CWWeight and dimensions

23+2

570

570

250

015CW

23+2

570

570

250

020CW

220-240/1/50

OPTIONS ON REQUEST

Electronic controls for wall mounted installation:- SLM3- NETWARE3Valve kit, 3 ways

GENERAL CHARACTERISTICS

3 range of ceiling cassette:- MCK-CW - 570 mm (w) x 570 mm (l)- MCK-AW/AWH - 820 mm (w) x 820 mm (I)4 way air discharge to provide better air distribution to roomAutomatic air swing4 pipes system available for models MCK020÷050AWHEasy servicing and maintenanceCondensate water up to 700 mm highAble to communicate with the versatile NIMSelf diagnosis featureWireless G17 control mode: selection, fan speed, 24 hours real timers

Page 105: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA MCK - Cassette

MCK - CassetteFAN COILS

103

FAN

CO

ILS

C

B

AA

C

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed(3) Sound pressure levels are tested at 1.4 m below the centre of the unit (according to JIS C 9612 standard) - MCK 020AW - MCK 025AW and 1.5 m below the centre of the unit (according to JIS B8615) - MCK 030AW - MCK 040AW - MCK 050AW(4) High speed

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 70/60°C inlet/outlet water temperature; 20°C inlet air temperature; high speed(3) Sound pressure levels are tested at 1.4 m below the centre of the unit (according to JIS C 9612 standard) - MCK 020 AWH - MCK 025 AWH and 1.5 m below the centre of the unit (according to JIS B8615) - MCK 030AWH - MCK 040AWH - MCK 050AWH(4) High speed

Weight and dimensions

Shipping weight (unit + panel)

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

020AW/AWH

31+4

820

820

305

025AW/AWH

32+4

820

820

305

030AW/AWH

35+4

820

820

305

050AW/AWH

40+4

820

820

305

040AW/AWH

38+4

820

820

305

Nominal Air Flow

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

mm

1310/1130/1069

6,62

4,90

8,40

0,316

24,8

42/39/37

0,130

0,52

3/4”

19

020AWMCK 2 PIPE

1379/1180/1069

7,50

5,40

9,50

0,358

30,8

45/42/40

0,150

0,64

3/4”

19

025AW

1558/1321/1209

8,80

6,40

11,0

0,421

41,6

49/45/43

0,160

0,68

3/4”

19

030AW

1738/1530/1339

9,95

7,10

12,0

0,475

52,2

51/48/46

0,190

0,79

3/4”

19

040AW

1839/1681/1540

10,8

7,70

12,9

0,516

69,3

53/52/50

0,250

1,06

3/4”

19

050AW

220-240/1/ 50

Nominal Air Flow

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

mm

1310/1130/1069

3,81

3,40

10,6

0,182

3,56

42/39/37

0,122

0,53

3/4”

19

020AWHMCK 4 PIPE

1379/1180/1069

3,96

3,52

11,0

0,189

3,78

45/42/40

0,138

0,61

3/4”

19

025AWH

1558/1321/1209

4,63

4,07

12,5

0,221

4,96

49/45/43

0,153

0,67

3/4”

19

030AWH

1738/1530/1339

5,01

4,40

13,5

0,239

5,70

51/48/46

0,184

0,80

3/4”

19

040AWH

1839/1681/1540

5,16

4,54

13,8

0,246

5,96

53/52/50

0,232

1,02

3/4”

19

050AWH

220-240/1/50

Page 106: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

104

MCW - Ceiling concealedFAN COILS

FAN CO

ILS

Cooling capacity: 2,20 kW ÷ 9,80 kWHeating capacity: 2,40 kW ÷ 12,2 kW

H2O

OPTION ON REQUEST

Electronic thermostat for wall mounted installation (AC8000; AC8000-NIM):DISPLAY LCD: • easy to operate full graphical user interface • allows an easy reading of the operating and auto-diagnosis parametersKEYBOARD allows to set parameters as follows:• set point temperature • fan speed selection • operating mode summer/winter • on/off • timer with 2 daily setting (14 weekly)• NIM connection (AC8000-NIM)REMOTE CONTROL AC5300:• infra-red control, allowing unit settings to be made remotely

Mechanical thermostat (AC512-2pipes; AC513-4pipes)• ambient temperature, fan speed, on/off

Valves kit 2 or 3 ways

GENERAL CHARACTERISTICS

With available external static pressure values up to 60 Pa, MCW models are suitable both for ducted and free discharge installations. Their compact dimensions and particularly low height, make units ideal for false ceiling installation even in vintage buildings with narrow ceiling spaces.Units are standard supplied with return plenum, air filter and extended drain pan. It is possible to field change connection side, for both 2 and 4 pipe versions, adding to the units flexibility and ease of installation.

M• a

sett

ostat (AC512-2pipesture, fan speed, on/off

nical ttem

he

tallation

th 2 dailconnection (A

MOTE CONTROL Anfra-red control, a

em

Mechanical thermoambient temperatu

ves 2 or

ed conely

nical tht tem

parameters as fe

m

eC8C53

owing un

/w

(14 wee

mount

tee operat

llo

nnection (OTE CONTROL A

fra-red control, mote

echanical thermmbient tempera

es kit 2 o

daonnection (A

OTE CONTROL Anfra-red control, am

Mechanical thermoambient temperat

ves kit 2 or

red conely

anical thent temp

arameters as

mmer

tting (14 weekly)8000-NIM)

300:wing u

parameters as

m

etting (14 weekly)8053

wing un

r/

(14 weekIM)

moun

erfaceopera

ows:

mount

terfacee opera

lo

Page 107: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA MCW - Ceiling concealed

MCW - Ceiling concealedFAN COILS

105

FAN

CO

ILS

C

AB

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

kg

mm

mm

mm

20/22

814

590

249

200C/HWeight and dimensions

Shipping weight C/H

(A) Length

(B) Width

(C) Height

23/27

984

590

249

300C/H

28/31

1114

590

249

400C/H

44/48

1564

590

249

800C/H

50/56

1924

590

249

1200C/H

48/52

1664

590

249

1000C/H

33/36

1314

590

249

600C/H

NOTES: (1) At the following nominal conditions: nominal air flow; 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; Super high speed(2) At the following nominal conditions: nominal air flow 50°C inlet water temperature;20°C inlet air temperature; same water flow as for cooling; Super high speed(3) At Super-high/High/Medium/Low speed; nominal air flow, with plenum and filter(4) At Super-high speed

Nominal Air Flow(super high/high/medium/low)

Available External Static Pressure

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop - (cooling)

Sound Pressure Level3

Power Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

Pa

kW

kW

kW

l/s

kPa

dB(A)

kW

V/ph/Hz

inches

inches

327/307

269/246

30

2,20

1,50

2,40

0,106

13

38/36/32/31

0,039

3/4"

3/4"

200CMCW - 2 PIPE

572/456

380/290

30

3,40

2,50

4,10

0,162

13

42/40/37/35

0,062

3/4”

3/4”

300C

710/541

475/445

30

4,20

3,30

5,40

0,201

19

41/37/33/32

0,079

3/4”

3/4”

400C

1264/1018

863/717

30

7,10

5,60

8,80

0,337

15

43/40/38/36

0,148

3/4”

3/4”

800C

1000/785

630/510

30

6,10

4,70

7,30

0,288

34

43/40/38/36

0,107

220-240/1/50

3/4”

3/4”

600C

1436/1234

1115/805

30

8,20

6,50

10,2

0,388

15

46/43/41/39

0,165

3/4”

3/4”

1000C

1785/1500

1298/1106

30

9,80

7,70

12,2

0,464

26

46/44/41/39

0,215

3/4”

3/4”

1200C

NOTES: (1) At the following nominal conditions: nominal air flow; 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; Super high speed(2) At the following nominal conditions: nominal air flow 70/60°C inlet/outlet water temperature;20°C inlet air temperature; Super high speed(3) At Super-high/High/Medium/Low speed; nominal air flow, 1 m below the unit (according to JB/T 4283-91)(4) At Super-high speed

Nominal Air Flow(super high/high/medium/low)

Available External Static Pressure

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop - (cooling)

Sound Pressure Level3

Power Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

Pa

kW

kW

kW

l/s

kPa

dB(A)

kW

V/ph/Hz

inches

inches

314/290

257/241

30

2,20

1,40

2,70

0,102

12

38/35/33/31

0,040

3/4”

3/4”

200HMCW - 4 PIPE

529/422

338/298

30

3,20

2,40

4,10

0,153

11

42/40/37/35

0,057

3/4”

3/4”

300H

671/536

494/460

30

4,10

3,10

5,30

0,194

18

41/38/34/33

0,072

3/4”

3/4”

400H

1194/963

856/700

30

6,80

5,40

8,50

0,324

14

44/40/38/36

0,137

3/4”

3/4”

800H

1004/811

725/653

30

6,10

4,70

7,70

0,289

34

43/40/38/36

0,106

3/4”

3/4”

600H

1346/1154

1039/743

30

7,80

6,10

9,50

0,373

14

46/43/41/39

0,160

3/4”

3/4”

1000H

1674/1406

1200/1069

30

9,40

7,30

11,7

0,446

24

47/44/42/40

0,203

3/4”

3/4”

1200H

220-240/1/50

Page 108: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

106

MCC - Ceiling concealed ductedFAN COILS

FAN CO

ILS

Cooling capacity: 2,90 kW ÷ 15,8 kWHeating capacity: 3,57 kW ÷ 19,6 kW

GENERAL CHARACTERISTICS

Available in 8 sizes, MCC line offers a wide range of solutions to air distribution problems applicable on both new and refurbished buildings.The robust construction is of corrosion-proof galvanised aluminium.

TECHNICAL DATA MCC - Ceiling concealed ducted

H2O

C

BA

B

ew andble on be onble on

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed - MCC 010CW - MCC 015CW - MCC020CW - MCC025CW and 70/65°C inlet/outlet water temperature; 20°C inlet air temperature;high speed - MCC 030CW - MCC 040CW - MCC 050CW - MCC 060CW(3) Sound pressure levels are tested at 1.4m below the centre of the unit, with 2m length duct at the air discharge outlet and air return inlet (according to GB/D17758)(4) High speed

Nominal Air Flow(super high/high/medium/low)

Available External Static Pressure4

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

Pa

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

inches

-/511

443/374

49

2,90

2,05

3,37

0,133

11

33/30/26

0,068

0,30

3/4"

3/4"

010CWMCC

-/868

749/612

49

3,40

3,10

4,40

0,160

24

37/34/29

0,097

0,42

3/4"

3/4"

015CW

-/1188

1156/1055

69

5,28

3,69

6,74

0,252

20

38/36/34

0,141

0,64

3/4"

3/4"

020CW

(1530)/1411

1292/1206

167

8,21

5,83

10,6

0,391

15

(49)/46/42/38

0,401

1,87

220-240/1/50

3/4"

3/4"

030CW

-/1242

1224/986

59

6,59

4,62

8,50

0,314

32

40/39/36

0,165

0,73

3/4"

3/4"

025CW

kg

mm

mm

mm

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

(1868)/1800

1681/1530

176

11,1

7,80

13,5

0,533

21

(51)/49/45/41

0,448

2,00

3/4"

3/4"

040CW

(2804)/2599

2430/2192

156

15,8

11,1

19,6

0,755

8

(53)/52/50/47

0,562

2,47

3/4"

3/4"

060CW

(2700)/2344

2174/2056

156

13,8

9,64

16,7

0,656

41

(53)/52/50/47

0,510

2,26

3/4"

3/4"

050CW

17

765

411

261

010CW

21

905

411

261

015CW

22

1065

411

261

020CW

39

929

541

379

030CW

25

1200

411

261

025CW

42

1045

541

378

040CW

63

1299

541

378

060CW

54

1299

541

378

050CW

m3/h

Page 109: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

TECHNICAL DATA MDB - Large ducted

MDB - Large ductedFAN COILS

GENERAL CHARACTERISTICS

High air flow and high external static pressure, enables adequate distribution of air to the desired spaceMultiple rooms can be cooled by just 1 unitSimple design with easy serviceability featureThe robust unit is designed with durability and reliability

Cooling capacity: 21,4 kW ÷ 46,2 kWHeating capacity: 46,9 kW ÷ 96,4 kW

H2O

C

A B

107

FAN

CO

ILS

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed(3) Sound pressure levels are tested at 1.4m below the unit (free return and the discharge air was ducted to adjacent room)

Nominal Air Flow

Available External Static Pressure

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input

Current Input

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

Pa

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

inches

4248

100

22,2

16,5

22,9

1,058

35

56

0,810

3,7

1 1/8”

1”

075BWMDB

5436

100

27,8

20,3

28,6

1,330

42

57

1,781

7,68

1 1/8”

1”

100BW

7135

149

36,6

26,4

40,5

1,750

49

58

1,550

2,95

1 1/8”

1”

125BW

7815

100

44,0

31,2

49,8

2,100

53

59

1,620

3,1

1 1/8”

1”

150BW

220-240/1/50 380-415/3/50

kg

mm

mm

mm

96

1502

761

572

075BWWeight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

100

1502

761

572

100BW

140

1640

7040

885

125BW

145

1640

7040

885

150BW

Page 110: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

108

MWM - Wall mountFAN COILS

GENERAL CHARACTERISTICS

The MWM series delivers a high standard of air quality characteristics in all applications. The automatic control of the airflow direction allows distribution into every corner of the room. The three-stage active filtration, removes dust and particles with diameters down to 0.01 micron. Its ionised filter prevents potential bacteria proliferation and minimises unpleasant smells, maintaining a clean and healthy environment. The use of random-pitched fan blades makes the MWM models extremely quiet. All key components can be accessed by simply removing the front cover, easily facilitating routine service tasks such as grille and filter cleaning. Detection and identification of any potential non-correct operation is signalled by a blinking LED on the remote display.

FAN CO

ILS

TECHNICAL DATA MWM - Wall mount

Cooling capacity: 2,34 kW ÷ 5,28 kWHeating capacity: 3,02 kW ÷ 6,74 kW

H2O

C

AB

an

outine service tsignalled by a blin

a clean a

asks such king LED

utine serviceignalled by a boutine service

signalled by a bliled b

a clean

ks suchng LED

a clean

sks suching LED

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

007GW

10

799

198

260

010GW

12

899

198

260

015GW

12

899

198

260

025GW

16

1062

222

304

020GW

16

1062

222

304

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed(3) At High/Medium/Low speed; position of the measurement point 1 m in front of the unit and 0.8 m below the unit (according to JIS C9612)(4) High speed

Nominal Air Flow (High/Medium/Low)

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

mm

468/382/299

2,34

1,74

3,02

0,111

48,3

40/35/29

0,240

0,11

1/2”

16

007GWMWM

511/425/338

2,78

2,03

3,75

0,133

64,7

39/34/28

0,250

0,11

1/2”

16

010GW

587/486/374

3,22

2,35

4,10

0,152

76,7

42/36/29

0,290

0,13

1/2”

16

015GW

1069/832/749

4,54

3,65

6,01

0,216

50,3

49/44/42

0,660

0,29

1/2”

20

020GW

1123/986/799

5,28

4,33

6,74

0,252

69,3

49/47/45

0,690

0,30

1/2”

20

025GW

220-240/1/50

Page 111: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

109

FAN

CO

ILS

MCM - Ceiling convertibleFAN COILS

GENERAL CHARACTERISTICS

The MCM series combines an attractive design with flexibility in satisfying application needs.The two-way air discharge coupled with the air swing function, provides excellent air distribution into the conditioned space. The three-stage active filtration, removes dust and particles with diameters down to 0.01 micron. Its ionised filter prevents potential bacteria proliferation and minimises unpleasant smells, maintaining a clean and healthy environment.Air filter and unit components can be easily accessed from the bottom side thus facilitating servicing tasks.

TECHNICAL DATA MCM - Ceiling convertible

Cooling capacity: 4,54 kW ÷ 13,2 kWHeating capacity: 5,72 kW ÷ 15,1 kW

Series EW

Series DW

H2O

C

B

A

B

ks.

ioned sp

an

icing tasks.

the cond

a clean a

ng taskcing tasks

he con

a clean

the cond

a clean

aircool / McQuay reserves the right to make changes in design and construction at anytime without notice

Weight and dimensions

Shipping weight

(A) Length

(B) Width

(C) Height

kg

mm

mm

mm

NOTES: (1) At the following nominal conditions: 7/12°C inlet/outlet water temperature; 27°C db / 19°C wb inlet air temperature; high speed(2) At the following nominal conditions: 50°C inlet water temperature; 20°C inlet air temperature; same water flow as for cooling; high speed(3) At High/Medium/Low speed; position of the measurement point 1 m in front of the unit and 1 m below the unit (according to JIS B8615) - MCM 030/040/050 DW; position of measurement point: 1 m in front and 0,8 m below the vertical centre line of the unit(4) High speed

Nominal Air Flow (High/Medium/Low)

Total Cooling Capacity1

Total Sensible Capacity1

Heating Capacity2

Water Flow Rate (cooling)

Water Pressure Drop (cooling)

Sound Pressure Level3

Power Input4

Current Input4

Standard Voltage

Water Connections

Condensate Drain Connections

m3/h

kW

kW

kW

l/s

kPa

dB(A)

kW

A

V/ph/Hz

inches

inches

850/763/680

4,54

3,72

5,72

0,216

27,4

50/43/41

0,100

0,46

1/2”

3/4”

015EW

986/901/833

5,95

4,52

7,33

0,283

48,1

53/51/49

0,110

0,49

1/2”

3/4”

020EW

1775/1652/1530

6,15

4,73

8,21

0,294

57,1

56/51/44

0,110

0,52

1/2”

3/4”

025EW

1184/1170/1102

7,21

5,19

8,70

0,345

49,4

51/50/48

0,130

0,57

3/4”

3/4”

030DW

1620/1541/1512

9,41

7,50

12,4

0,436

24

54/53/52

0,240

0,98

3/4”

3/4”

040DW

1800/1750/1620

13,2

9,20

15,1

0,630

37,7

54/53/52

0,240

1,03

3/4”

3/4”

050DW

015EW 050DW

MCM

220-240 V / 1ph / 50Hz

27

1090

630

213

020EW

27

1090

630

213

025EW

27

1090

630

213

030DW

45

1214

670

214

040DW

70

1714

670

249

70

1714

670

249

Page 112: Engineered for flexibility and performance · GENERAL-CATALOGUE Engineered for flexibility and performance. AIR TO WATER HEAT PUMPS AIR COOLED CHILLERS FREE COOLING FAN COILS A GLOBAL

2010/2011_ENG

McQ

uay

rese

rves

the

right

to c

hang

e de

sign

and

spe

cific

atio

ns w

ithou

t prio

r not

ice.

A Global Leader In System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration

2010/2011

GENERAL-CATALOGUE