enertronic high voltage, power & automatism v01
TRANSCRIPT
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
NUCLEAR RAILWAYOIL & GAS MARINE
MILITARY & AERO
BIG SCIENTIFIC INSTRUMENTSRENEWABLE ENERGIES
HIGH VOLTAGE
FUEL CELL
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Automatisms
Security PLCs (RCCE-C3; RCCE-C2), Seismic qualified (K3) :
STEPLINE
STEPLINE K3C2 / K3C3
Real-Time Controller
ENERTRONIC propose different kind of products developed by a full team of competencies and complementarities :
Power Electronics
DC/DC Converters
AC/DC Power Supply
DC/AC Inverters
DC/AC Speed Drives
Solid-state THT ultra Fast Switches
Pulsed Electric fields, Pulsed Power Supply
Crowbars
Very High Voltage
AUTOMATISMPOWERHIGH VOLTAGE
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Functions / Markets
Industry
Ionic Implant
Semiconductors Industry
Pulsed Lasers
Magnetron
Bacteria Deactivation
Water Treatment
Plasma Generators
Thin layers deposit
Dielectric barrier
Discharge
Product / Markets
Big Scientifics
instruments
Particle Accelerators /
SYNCHROTRON
Inertial Containment
Magnetic Containment
for Plasma / TOKAMAK
Nuclear reactors
Protection of Klystrons /
Tubes
Military
Pulsed High Energies
AUTOMATISMPOWERHIGH VOLTAGE
FUNCTIONS / PRODUCTS / MARKETS
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Products :
Switch
Crowbar
Pulsed Energy
Crowbar / Switch for Kickers – MOS :
• Deviation of Beams in Particle Accelerators - SYNCHROTRON
• 25 kV / 2.7 kA / Jitter = 1 ns
• Air cooling
Solid State : Matrix of Semiconductors
Cooling : Air / Water / Oil
PRODUCTS : SWITCH / CROWBAR / PULSER
Switch – MOS :
• Protection of Klystron generating magnetic containment of Plasma in TOKAMAK
• 120 kV / 70 A DC / Reaction Time < 2 µs
• Oil cooling
Pulsed Energy – MOS :
• Power supply of Pulsed Laser
• 25 kV / 1.5 kA / 6kHz
• Oil cooling
AUTOMATISMPOWERHIGH VOLTAGE
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Products :
Pulsed Energy – MOS + IGBT :
• Reactor of Ionic Implant – Semiconductor - Rack 19’’• 20 kV / 150 A / 20 kHz
• Air cooling
Switch – Thyristor :
• Switch for Laser
• 20 kV / 4 kA / 10 kHz
• Oil cooling
Pulsed Electric Generator – MOS + IGBT :
• Reactor of Ionic Implant – Semiconductor - Rack 19’’
• 40 kV / 150 A / 10 kHz
• Oil container, Water cooling with integrated thermal exchanger
PRODUCTS : SWITCH / CROWBAR / PULSER
AUTOMATISMPOWERHIGH VOLTAGE
Switch
Crowbar
Pulsed Energy
Solid State : Matrix of Semiconductors
Cooling : Air / Water / Oil
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Functions – Single Boards :
Voltage Switch : ON / OFF
• MOS 10 kV / 150 A, tR / tF≤ 200ns at nominal charge, resistant to short-circuits• IGBT 10 kV / 2kA , tR / tF≤ 300ns at nominal charge
Crowbar or Voltage Rectifier drived : ON
• Thyristor, 10kV/4kA tR≤ 700ns at nominal charge• MOS 5 kV / 700 A, tR≤ 200ns at nominal charge• IGBT 10 kV / 3kA , tR≤ 300ns at nominal charge
Voltage rectifier :
• Diode : 10kV/500A
Diode - ON (function Thyristor)
ON / OFF (Switch)
Matrix of Standard ComponentsSwitch frequency : up to 20kHz
Time Stability : up to 1ns
FUNCTIONS FOR PRODUCTS : VOLTAGE RECTIFIER / CROWBAR / SWITCH
Other Functions :
• Discharge of Energy + Voltage measure : ON/OFF, 10kV / 1kΩ + Voltage divider (BP > 10MHz)
• Voltage Switch : ON/OFF association + diode
Voltage / Board : 5kV or 10kV unit - Serial assembly for increasing Voltage
Current / Board : From 100A (MOS ON/OFF) up to 3kA (MOS, IGBT or Thyristor) - Parallel assembly for increasing Current
AUTOMATISMPOWERHIGH VOLTAGE
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Railway DC/DC converter for tramway
Auxiliary DC/DC converter
Automotive Hybrid & FUEL CELL
Aerospace Fuel CELL for flying drone
DC/DC convertersDC/AC Inverters
SPEED DRIVES
Railway
Power supplies for air
conditioners Tramway
Industry
Air conditioners
Compressors
AC/DC POWER SUPPLIES
Industry
PROGRAMMABLE LOGIC
CONTROLLER
HIGH VOLTAGE (>10KV)
AUTOMATISMPOWERHIGH VOLTAGE
CONVERTERS / INVERTERS / POWER SUPPLY / SPEED DRIVES
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Hardened industrial product (temperature, Electromagnetic compatibility, …)
Charge reduced rate on components
High MTBF
Green Power
Eco-Design
Quality / reliability
High efficiency of the systemélevé du système (=> 96% - 98%)
Standby and reduced consumption
RoHS
Recyclable electronic elements
Quick dismantlement
Converter of 24 kW made of a volume of 24 liters
Small Size / Space saving
AUTOMATISMPOWERHIGH VOLTAGE
CONVERTERS / INVERTERS / POWER SUPPLY / SPEED DRIVES
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Examples of Achievements :
Drone & Sailing ship Zero CO2 : Double Converter Common water cooling
• Converter n°1 : Fuel Cell H2 = 23 kW (150V, 150A => 360V, 60A)
• Converter n°2 : battery charger= 1,5 kW (360V => 12 V)
Hybrid vehicle : 2 Compactness converters(9,5 cm) water cooling
• Converter n°1 : Fuel Cell H2 = 23 kW (150V, 150 A => 360V, 60A)
• Converter n°2 : Battery charger= 2 kW (360V => 12 V)
Tramway : Double converter - Cooling by Natural Convection
• Converter n°1 : Battery charger = 20 kW (750V=> 72V)
• Converter n°2 : Auxiliary Power= 5 kW (72V => 24 V)
22,6l – 24 kg
9,5l – 11 kg
390 x 264 x
215 – 15 kg
160 x 100 x
40
1400 x 1000 x
375 – 250 kg
24 V - 48 V - 72 V
110 V - 750 V
Output = DC Voltage
3,3 V 5 V +/- 12 V
+/- 15 V 24 V 72 V
Input = DC Voltage
Railway : Converter : 80 W - Efficiency > 90%• 80 W (72 V, 20 A => 24 V, 3.5A) Operating temperature : - 25°C / + 70°C
• Active amplitude chopper : 100V during 1s; 252 V during 20 ms
AUTOMATISMPOWERHIGH VOLTAGE
DC / DC CONVERTERS
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Output = DC VoltageINPUT ~ AC Voltage
3 x 400 V
Three phases
V adjustable : 0 to 1 000 V
I adjustable : 0 to 3 A
Electric specifications :
Input :
Input Voltage: 3*400Veff (±10%) (3 phases + ground)
Frequency : 47Hz/63Hz
Efficiency: > 85% à 3kW
Output :
Adjustable power : 0 à 3000W ±5%
Adjustable voltage : 0 à 1000V ±0.5%
Adjustable current 0 à 3A ±2%
Residual energy : 0.11W.s without crowbar
Crowbar : in the event of an arc, the output can be shorted-circuit in
less than 1µs.
A3-1000 : 3A 1000V with Arc Detection
AUTOMATISMPOWERHIGH VOLTAGE
AC / DC POWER SUPPLY
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Examples of Designs & Industrialization :
OUTPUT = DC VOLTAGEINPUT ~ AC VOLTAGE
85 V à 260 V
Single-phase
3,3 V 5 V +/- 12 V
+/- 15 V 24 V 72 V
Industry : Security PLC
• Power supply of PLC
• 50 Watts
Aeronautics: Helicopter NH90
• Power supply of radio receiver (detection underwater tags)
• 20 Watts
• 2 versions : 115 Vac and 24 Vac
Aeronautics: Planes AIRBUS
• Power supply of the Flight recorders
• 300 Watts
• Aeronautical & Military standards
AUTOMATISMPOWERHIGH VOLTAGE
AC / DC POWER SUPPLY
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
OUTPUT ~ AC VOLTAGE
230 Vac to 460 Vac
Mono/Di/Triphase - 0 à 120Hz
48 V - 72 V - 750 V
1500 V - 3000 V
INPUT = DC VOLTAGE
Examples of Achievements :
Tramway : Chopper + Inverter for air conditioner - Triphase
• Power : 10 kW : 750 Vdc => 460 Vac 50 Hz / 60 Hz
• Forced air cooling
DC / AC INVERTER & DC / AC SPEED DRIVE
Engine of Traction : Inverter for air conditioner - Triphase• Power : 5 kW : 72 Vdc => 400 Vac 50 Hz / 60 Hz
• Forced air cooling with integrated ventilator
600 x 400 x
400 – 40 kg
1200 x 500 x
400 – 80 kg
Subway : Inverter with PLC- Mono & Diphase
• Power : 1,5 kW : 750 Vdc => 3 outputs: 0 à 230 Vac / 0 à 50 Hz
• Forced air cooling with integrated ventilator
400 x 300 x
150 – 6 kg
AUTOMATISMPOWERHIGH VOLTAGE
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
STEPLINE Programmable
Logic Controller - PLC
CONTREE Real-Time
Controller
HMI Human-Machine
Interface
Fuel Cell
Industry
Railway
Nuclear
Industry
Oil & Gas
Military
AUTOMATISM POWER HIGH VOLTAGE
PROGRAMMABLE LOGIC CONTROLLER / REAL-TIME CONTROLLER
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Real-Time Controller
Fuel Cell
Battery Management System
BMS for Lithium Ion Batteries
Railway
Nuclear
Industry
Oil & Gas
Marine
Seismic
Programmable Logic
Controller - PLC
Programming according EN61131-3
Programming in C
AUTOMATISM POWER HIGH VOLTAGE
PROGRAMMABLE LOGIC CONTROLLER / REAL-TIME CONTROLLER
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
AUTOMATISM POWER HIGH VOLTAGE
STEPLINE PLCs
Standardization / Adding easy of functionality
Simplified study in case of obsolescence of components
Dimensions
Ruggedized Electronic
Modular design
Rack in stainless steel, dedicated for severe Environment
Format : Single EUROPE (100 x 160 mm)
Sizes depending on the number of I / O: 6T, 9T, 15T, 21T
Resistance to extreme temperatures without forced ventilation
Design constraints (load rate of the components, max temp junctions ...)
EMC / Vibration / Tropicalization / Saline Atmosphere
Fallback position of outputs guaranteed
Auto test for inputs/outputs and memories
Safety
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
Expertise in PLCs
85,000 PLCs in operation since 1996
40,000 PLCs working for Railway Applications
Feedback on electronic control for over 40 years
STEPLINE PLCs
STEPLINE range in service since 2005
PLCs range of continually evolving
Temperature range without forced ventilation: -25°C / +70°C
AUTOMATISM POWER HIGH VOLTAGE
STEPLINE PLCs
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
STEPLINE K3C3 PLC
AUTOMATISM POWER HIGH VOLTAGE
PROGRAMMABLE LOGIC CONTROLLER - PLC
Generic NameFunctionality
RACKRACK INOX ENERTRONIC Special severe EnvironmentFormat : SINGLE EUROPE 6T, 9T, 15T, 21T
CPUCentral processing unit,Network : Can Open
Inputs 24Vdc Modularity : 16 Logical Inputs
Outputs 24Vdc Modularity : 16 Logical Outputs – 200mA or 8 Logical Outputs - 2A
Relay Outputs Modularity : 16 Logical Outputs
Analog boardModularity : 8 Analog InputsVoltage, Current, Pt 100, Pt 1000
Safety PLC (RCCE-C3; RCCE-C2), seismic qualified (K3)
Applications: Nuclear Safety, Oil & Gas Operations…
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
CONTREE : Real-Time Controller
L/l/H : 315mm*105mm*75mm
AUTOMATISM POWER HIGH VOLTAGE
REAL-TIME CONTROLLER
Low-cost Programmable Automation Controller
Base : Microcontroller / DSP
Modularity : 4 logical or analog Inputs/outputs blocks
Ultra compact and hardened system for data acquisition, control and process control.
Applications requiring high performance and reliability.
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
ENERTRONIC relies on an experienced team with strong expertise and
recognized in the field of electronics and automation.
ENERTRONIC achieves :
Design and Industrialization
Research and Development
Expertise, Advice and Technical Assistance
Design Means :
Electronics design (schematic, CAD, CAD ...)
Electrical design
Mechanical concept
Thermal design
Numerical Simulation
Test Means :
High voltage tests (<2000 V)
Tests Extra High Voltage (10 kV => 500 kV)
EMC testing Pre-Qualification Test
Thermal Testing and Burn In
Climatic test
AUTOMATISMPOWERHIGH VOLTAGE
SERVICES
Development based on Customer Specifications:
HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE ---- POWER POWER POWER POWER ---- AUTOMATISMAUTOMATISMAUTOMATISMAUTOMATISM
WHO WE ARE …
A French company of 160 persons
Conception/industrialization & Production
Thermodynamic Systems:
Reinforced seismic Chillers Nuclear
Hardened mechanical stresses Heat Pump Railway
Comfort in extreme conditions - 46 °C / + 58 °C
Cold and autonomous refrigerator container
Air conditioning unit Military
Autonomous air conditioning Trailer
Electronics :
Secured controllers ( K3C3 , K3C2 )
Power Electronics : Alims , converters
High Voltage : Ultra high speed Switches
RAILWAY Air/air AC Units 1 to 50 kW
Heat Pump 50 kW
MILITARY Air/air autonomous AC Units 3 to 50kW
MARINE Water/air AC Units 5 to 40kW
OIL & GAS ATEX Liquid Chiller
cooling capacity up to 3 000kW
HYBRID Gas Heat Pump & Fuel Cell
NUCLEAR Chillers
10 to 3 000kW
DESERT CONDITIONS