emergency light gen. info

4
Emergency Lighting System Do you know how important it is to provide the escape route? that you can prevent tragedies caused by panic with the appropriately installed emergency lighting? how to meet the stringent requirements of the emergency lighting systems? ASM Security Ltd. Hungary, 5002 Szolnok, Hrsz: 0149/58 Tel.: +36-56/510-740 Fax: +36-56/510-741 E-mail: [email protected] Skype: asmexport www.asmcamera.com For your safety. s research and development engineers have created the CLEVER LIGHT system. Our unique lighting system meets the requirements. HUNGARIAN INNOVATION

Upload: aaaaaa

Post on 30-Dec-2015

18 views

Category:

Documents


1 download

DESCRIPTION

Clever Light General Info

TRANSCRIPT

Page 1: Emergency Light Gen. Info

Emergency Lighting System

Do you know how important it is to provide the escape route? that you can prevent tragedies caused by panic with the appropriately installed emergency lighting? how to meet the stringent requirements of the emergency lighting systems?

ASM Security Ltd.Hungary, 5002 Szolnok, Hrsz: 0149/58 Tel.: +36-56/510-740 Fax: +36-56/510-741

E-mail: [email protected] Skype: asmexport www.asmcamera.comFor your safety.

’s research and development engineers have created the CLEVER LIGHT system. Our unique lighting system meets the requirements.

HungAriAn innovAtion

Page 2: Emergency Light Gen. Info

Legal background

Why do you need an Emergency Lighting System? Why is it so important?

The fire or electrial outage or similar disaster can create a serious emergency for occupants who are present in the high-traffic areas shopping centers, offices, factories .

PURPOSE: The illumination of the exit ways should ensure the areas safe to leave.

For your safety.

The operator has to ensure the control and the periodic maintenance of the exit lights. It guarantees the system’s perfect operation.

ASM Security Ltd.Hungary, 5002 Szolnok, Hrsz: 0149/58 Tel.: +36-56/510-740 Fax: +36-56/510-741 E-mail: [email protected] Skype: asmexport www.asmcamera.com

Daily: Visually check that all maintend lamps are operating and that all system healthy indicators on Central Power Supply System are illuminated. Check that any recorded system fault is given urgent attention and record all corrective actions in the logbook provided.

Monthly: Check all luminaires and other emergency lighting equipment are in a good condition, all lamps and light controllers are clean, undamaged and not blackened. Briefly test all emergency lighting equipment by simulating a failure of the normal lighting supply. The test should not exceed a quarter of the equipment functions correctly. Check that, upon restoring the mains supply, all supply healthy indicators are again illuminated.

Six Monthly: Carry out the inspection and testing as described in the monthly test schedule, but conduct a test of the equipment for one third of its rated duration.

Annually: A full system test should be conducted by a competent service engineer including a full rated duration test of the system. Compliance of the installation and system with the requirements of BS 5266 should be considered and documented.

Both BS 5266 and European draft standard prEN 50172 define detailed requirements for insection and testing at regular intervals. Emergency lighting testing requirements are detailed in ICEL 1008 and the general schedule of requirements is showed as follows:

Page 3: Emergency Light Gen. Info

Components of the system: lighting center, lights, accessories

For your safety.

CL-100, CL-200, CL-300, CL-400 Addressable lighting center Max. 100/200/300/400 devices Power source: 230 VAC 230V line communication (ASM BUS) UDP, MODBUS communication TCP/IP network interface

Conventional and addressable lights! Suspended ceiling-mounted EXIT luminare Ceiling mount EXIT luminaire Side wall EXIT luminaire Visual range: 20/27 meter With three-hour battery or without battery LED light

Conventional and addressable lights! 6W LED standby lighting Ceiling mount luminaire Side wall mount luminaire

Printer Driver for 100pcs of luminaires Line filter Programming software Dongle Graphics software modul for emergency lighting Graphics software modul for public lighting Power supply for center Battery Pictograms Communication unit

Lighting center

Emergency escape lighting

Standby lighting

Accessories

CLEVER LIGHT

www.asmcamera.com

ASM Security Ltd.Hungary, 5002 Szolnok, Hrsz: 0149/58 Tel.: +36-56/510-740 Fax: +36-56/510-741

E-mail: [email protected] Skype: asmexport www.asmcamera.com

Page 4: Emergency Light Gen. Info

Clever Light system

Addressable Energy saving Reduced maintenance costs Duplex communication among the master and the slaves – Continuous, automatic monitoring The luminaires can be controlled individually Web server function Graphics software Multi language menu Touch monitor Printer (optional)

CLEVER LIGHTAddressable Emergency Lighting from ASM

Graphics software

ASM Security Ltd.Hungary, 5002 Szolnok, Hrsz: 0149/58 Tel.: +36-56/510-740 Fax: +36-56/510-741 E-mail: [email protected] Skype: asmexport www.asmcamera.com

printer

Max. 100 devices

Max. 100 devices

touch monitor

Max.

1200

m

Max.

1200

m

GatewaY

pc

reMote control tcp/ip

CLEVER LIGHT

www.asmcamera.com

CLEVER LIGHT

www.asmcamera.com

CLEVER LIGHT

www.asmcamera.com

CLEVER LIGHT

www.asmcamera.com

For your safety.