eman-ksb etapump® solar water pump instruction manual

43
DANKOFF SOLAR PRODUCTS, INC. Santa Fe, NM USA (505) 473-3800 [email protected] www.dankoffsolar.com ETAPUMP® Solar Water Pump and ETAPUMP Integrated SystemINSTRUCTION MANUAL

Upload: moly69x

Post on 19-Jan-2016

78 views

Category:

Documents


0 download

DESCRIPTION

Design solar pumping system

TRANSCRIPT

Page 1: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

DANKOFF SOLAR PRODUCTS, INC.Santa Fe, NM USA

(505) [email protected]

www.dankoffsolar.com

ETAPUMP®

Solar Water Pumpand ETAPUMP Integrated System™

INSTRUCTIONMANUAL

1

Page 2: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

2

WARNINGS TO INSTALLER

Failure to follow these instructions will void the warranty.

Open circuit (no-load) voltage above 100V will destroy the controller. This may occur ifthe wrong PV modules (solar panels) are used, or if the solar array is incorrectlywired. Measure the array voltage before connecting to the controller. A “48V”(nominal) array should produce an open circuit voltage around 75-90V under anydaylight conditions. (See Solar Array Wiring, Section 5.3)Do not attempt to run the ETAPUMP Motor without the ETAPUMP controller.Do not attempt to use ETAPUMP controller for any pumps other than ETAPUMP.To be installed, connected and serviced by qualified personnel only. Ensure all powersources are disconnected when making connections to this unit. Follow all appropriateelectrical codes. There are no user serviceable parts inside the motor or the controller.

Undersized wire will cause failure to start. See Section 5.7.

Install proper grounding for safety and lightning protection (See Section 5.2)

Do not touch the controller input or pump wires together to test for a spark.

Do not run the pump dry. (Exception: to test direction of rotation, only for a fewseconds)Test the direction of motor rotation before installing the pump (counter-clockwiselooking down). If direction is reversed, exchange the connection of any two of thethree power wires to the pump. (See Section 5.8)

When pump is stopped by a shadow or by action of the float switch, it will restart aftera delay as long as 90 seconds. This is normal.If the low water probe is installed, it must be submersed along with the pump motor, orthe pump will stop for 30-35 minutes. A ground connection to the pump (4th wire) isrequired for low water probe to function. If the probe is not to be used, connect thecontroller’s probe terminal to ground. (See section 5.5 and 5.9)

Installation should be in accordance with local regulations and accepted codes of good practice.

This manual is the property of the ETAPUMP owner.Please give it to the owner or maintenance personnel when you are finished!

You may request additional copies from your ETAPUMP supplier

Copyright © 2002 by BERNT LORENTZ KG and DANKOFF SOLAR PRODUCTS, INC.All rights reserved

ETAPUMP is a registered trademark of BERNT LORENTZ KGETAPUMP INTEGRATED SYSTEM™ is a trademark of DANKOFF SOLAR PRODUCTS, INC.

Version 1.84August, 2002

!

!

!

!

!

!!

!

Page 3: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

3

2 SYSTEM REPORT FORM

Please enter system data before you start

This is necessary if you ever need advice or parts.

ETAPUMP Integrated System™ Number ETA - - .(Most non-battery ETAPUMP are sold with a complete system)

System Voltage ________ Date of Purchase ___________

Purchased from _________________

Battery System? ________ or Quantity of Solar Modules (panels) _______

Solar Module Brand ____________ Module Model # _______

Pump Model # _________ Pump End Serial # ______

Controller Model: [ ] EP600 (solar-direct only) Controller Serial # _________[ ] ME24/48 (battery only)

Motor Serial # _________ 1st two digits = voltage “55 …” is 48V “24 …” is 24V

Installation Report

Installation Date ___________ by: _____________________

Well Depth ______ [ ] feet [ ] meters Pump depth ____________

Additional Vertical Lift (up to top of tank) ___________

Static Water Level _________ Variable? _____________

Drop Pipe (vertical from the pump)

Size ________ Type ____________ Length ___________

Additional Pipe Length (to tank)

Size ________ Type ____________ Length ___________

Submersible Pump Cable

Wire size ________ Total Length (controller to pump) ___________

NOTES

Page 4: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

4

TABLE OF CONTENTS1 WARNINGS TO INSTALLER..........................................................................................................................................................22 SYSTEM REPORT FORM ..............................................................................................................................................................33 INTRODUCTION .............................................................................................................................................................................54 INSTALLING THE SOLAR ARRAY ................................................................................................................................................5

4.1 Location of the Solar Array .................................................................................................................................................54.2 Solar Array Assembly Methods ..........................................................................................................................................64.3 Solar Array Mounting Rack .................................................................................................................................................74.4 Orienting the Solar Array to Solar South ............................................................................................................................74.5 Setting the Solar Array Tilt Angle........................................................................................................................................8

5 ELECTRICAL INSTALLATION........................................................................................................................................................95.1 Controller, Disconnect Switch and Conduit ........................................................................................................................95.2 Grounding and Lightning Protection .................................................................................................................................125.3 Solar Array Wiring .............................................................................................................................................................135.4 Solar Array (PV) Disconnect Switch .................................................................................................................................145.5 Controller Input Wiring ......................................................................................................................................................145.6 Maximum RPM Setting .....................................................................................................................................................155.7 Submersible Pump Cable and Splice ...............................................................................................................................165.8 Wiring Order for Correct Rotation.....................................................................................................................................165.9 Low-Water Probe for Dry-Run Protection.........................................................................................................................175.10 Automatic Control For Full-Tank Shutoff ..........................................................................................................................185.11 Battery-Based Systems.....................................................................................................................................................185.12 Pressurizing Systems........................................................................................................................................................19

6 PREPARING TO INSTALL THE PUMP........................................................................................................................................206.1 Pump End to Motor Assembly ..........................................................................................................................................206.2 Drop Pipe...........................................................................................................................................................................206.3 Safety Rope and Binding ..................................................................................................................................................206.4 Installation in a Surface Water Source .............................................................................................................................216.5 Deep Well Setting — How Deep?.....................................................................................................................................226.6 Coping with Dirty Water Conditions..................................................................................................................................226.7 Utilizing a Low-Production Water Source.........................................................................................................................236.8 Installing the Pump Under a Windmill Cylinder ................................................................................................................23

7 IN-WELL ASSEMBLY AND INSTALLATION................................................................................................................................247.1 Rubber Spacers (Models –07 and –14 only)....................................................................................................................247.2 Machine Installation...........................................................................................................................................................247.3 Hand Installation................................................................................................................................................................257.4 Sanitizing the Well.............................................................................................................................................................25

8 OPERATING THE ETAPUMP (Solar-Direct)...............................................................................................................................268.1 Normal Noise and Vibration ..............................................................................................................................................27

9 TROUBLE SHOOTING..................................................................................................................................................................289.1 If the Pump Doesn’t Run...................................................................................................................................................289.2 Inspecting the System.......................................................................................................................................................289.3 Testing the System............................................................................................................................................................299.4 If the Pump Runs But Flow is Less Than Normal ............................................................................................................30

10 Maintenance ..............................................................................................................................................................................3110.1 Controller and Pump .........................................................................................................................................................3110.2 Solar Array.........................................................................................................................................................................3110.3 Electrical Wiring.................................................................................................................................................................31

11 ETAPUMP WARRANTY ...........................................................................................................................................................3212 ETAPUMP STANDARDS & ENVIRONMENTAL SPECIFICATIONS......................................................................................3213 REFERENCE SECTION ...........................................................................................................................................................33

13.1 Principles of Operation......................................................................................................................................................3313.2 Water Pipe Sizing Chart....................................................................................................................................................3513.3 Wellhead Assemblies for Drilled Wells .............................................................................................................................3613.4 Water Storage for Solar Water Pumps.............................................................................................................................3713.5 Monitoring a Solar Pump System .....................................................................................................................................3813.6 Freeze Protection for Solar Water Pumps........................................................................................................................3813.7 Obtaining and Using a Multimeter for Trouble Shooting..................................................................................................3913.8 A Meter for Measuring Solar Energy Intensity .................................................................................................................3913.9 Glossary of Solar Electricity and Water Pumping ............................................................................................................4013.10 Handy Facts & Formulae ..............................................................................................................................................43

Page 5: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

5

3 INTRODUCTION

Thank you for purchasing ETAPUMP ETAPUMP sets a new standard for quality and economy in solarpumping. It incorporates the best solar pump technologies that were very expensive until now. ETAPUMP isengineered in Germany and made in China by a German-owned high technology factory. Key components of thepump are made in Germany. It is imported for the Americas by Dankoff Solar Products, a pioneering solar pumpdeveloper since 1983.

Before you begin Check the model numbers of all the components of your system, and verify that they are theitems that you ordered. Also check against the ETAPUMP specifications and performance charts (end of thismanual) to be sure the system is appropriate for your application.

Please fill in the SYSTEM REPORT on page 3. This will be essential information if any problems occur.

This manual covers two types of systems, battery and solar-direct. If you purchased ETAPUMP to connect toa battery system, you can bypass the sections that solar-direct systems.

System Wiring Diagram (solar-direct only) If your pump was purchased as part of an ETAPUMPINTEGRATED SYSTEM™, a System Wiring Diagram should be attached at the back of this manual. Be sure thediagram is the correct one for the system you have.

REFERENCE SECTION (Section 13) Most ETAPUMP installers are new to solar pumping, so we provide helpfulinformation—principles of operation, instructions for wellhead assembly, water storage, control and monitoring ofwater supply, pipe sizing, freeze protection, and a glossary of technical terms.

4 INSTALLING THE SOLAR ARRAY

4.1 Location of the Solar Array

Sunlight is the “fuel” that drives a solar pump. Positioning of the solar array is critical for full performance of a solar-direct system.

Choose a location for the solar array that has unrestricted sun exposure through the day and through the year. Thearray can be placed several hundred feet (100 m) or more from the wellhead. There will be no loss of performanceif the electrical wire is sized properly, but naturally, the cost of wire will increase significantly. The ETAPUMPSystem Sizing Table specifies wire size requirements for both normal and extended wire lengths.

WARNING Shading a small portion of a PV array will cause the pump to slow or stop completely.

Each PV module (panel) contains a series of solar cells (typically 36 or 72 cells). Every cell that is shaded acts likea resistor, reducing the output of the entire array. Shading just one corner of the array will reduce the powerdisproportionately, and may even stop the pump. Consider this when deciding where to install the array.

To determine where shadows may be cast at any time of the year, you can survey the site with a Solar Pathfinder®.This device is especially useful in forested areas or wherever there are obstructions nearby. It is available directlyfrom Solar Pathfinder (USA) Tel. & fax (931) 593-3552, www.solarpathfinder.com.

Place the bottom edge of the array at least 2 feet (.6 m) above ground to clear rain spatter, growing vegetation andsnow. Keep in mind that trees and perennial plants will grow taller over the years, especially if they receive runofffrom a solar water pump!

Page 6: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

6

4.2 Solar Array Assembly Methods

LEFT Typical assembly of a solar array on a passive (non-electric) tracker. The tracker pipe was extended to about 10feet (3m), by welding it to a larger pipe. The array wasassembled and wired on the ground, then lifted and loweredonto the pole with the help of a backhoe and chain.

Wire is single-conductor type USE (outdoor rated). See howthe wire is looped. This allows it to shed water, and to flexeasily as the tracker swings East-West. Wires enter theconduit through a “weatherhead” fitting. Conduit enters thedisconnect switch through a “conduit hub”.

Assembling the array in place, overhead (not illustrated)WARNING Use extreme caution when assembling thearray above your head. You are dealing with a large andheavy assembly. The use of ladders can be dangerous. It isbest to assemble a platform using a strong scaffold assembly(the temporary platform system that is used for buildingconstruction). A scaffold system can be rented from a localsupplier.

RIGHT A PV array is installedwith a crane. Water wellcontractors often use their pump-pulling rig to do this.

Photo courtesy of Skyline Solar, Idaho,USA

Page 7: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

7

4.3 Solar Array Mounting Rack

WARNING All parts of your mounting structure must be engineered for wind resistance, ease ofadjustment, and safety. Follow the rack manufacturer’s instructions that are packed with your rack.

Solar Tracking A solar tracker is a special pole-mounted solar array rack that tilts automatically to follow the dailypath of the sun. In clear summer weather, it can increase your daily water yield by 40-50%. (It is much less effectivein winter and in cloudy weather.) A tracker is an option with ETAPUMP Integrated Systems™.

4.4 Orienting the Solar Array to Solar South

For full performance, your solar array must be oriented within 10° of true (solar) south. Depending on your location,a compass reading may show an error of as much as 20°. To correct this discrepancy, apply the magneticdeclination for your region. Many regional maps indicate the magnetic declination. If you don’t have a compass butcan see your shadow and know the time of day, use the Sun Compass™.

Sun Compass™

For the USA (lower 48 states) and other 25° to 55° North latitude regions.

Find True South quickly and accurately using only your shadow. No magnetic compass needed!

Sun Compass Instructions1. Draw an arrow from Month dot to intersection of your Standard Time and Latitude. (The gray line is an example: August, 2 PM at 40° N lat.)2. Stand and face your shadow.3. Hold this page horizontally.

North

Aug

8 AM

9AM

10AM11AM 1PM

2 PM

4PM

3PM

JulJun

Apr

Mar

Jan

Feb

May

Oct

Nov

Dec

Sep

2 PM3PM

4PM

10AM9AM

8 AM

11AM

South

6AM

7AM 5PM

6PM

East

© 1996 by John Veltman

50°

40°

30°

West

Page 8: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

8

4. Point the arrow that you drew to center of your shadow.

Sun Compass™ is available for the following latitudes:1. U.S.A. (25° to 55°) – shown here 3. Equatorial (20° N to 20° S)2. Northern (50° N to 70° N) 4. Southern (10° S to 40° S)To obtain reproduction rights, contact: John Veltman PO Box 23533, Santa Fe, NM 87502 USA

4.5 Setting the Solar Array Tilt Angle

Factory-built solar array racks are adjustable to the desired angle, to accommodate both the location and theseason. We offer these choices for seasonal management.

1. YEAR-ROUND COMPROMISE (no seasonal adjustment) Set the angle equal to the latitude of thelocation and “forget it”. This is practical because people often forget to adjust the array. The ETAPUMPSystem Sizing Table is based on this fixed angle setting.

2. SEASONALLY ADJUSTED It is sufficient to perform the adjustment only twice per year, at the spring andautumn equinoxes, to the angles indicated below. For central USA, daily water production will be increasedby about 8% in summer, 5% in winter compared to option 1. There is less advantage in a cloudier climate.

3. SEASONAL USE ONLY (summer-half or winter-half of the year) If the pump is to be used no more than6 months of the year, set the array to the seasonal angle shown below, and “forget it”.

CAUTION People often forget to make seasonal adjustments. If you use the pump all year but do not wantseasonal adjustment to be required, set the angle equal to your latitude (Year-Round Compromise).

Ideal angles (from horizontal) are: Summer optimum = latitude – 15° Winter optimum = latitude + 15°

Solar Array Tilt Angles by latitude Summer Winter Year-Round

Location (examples) Latitude Tilt Tilt CompromiseSouthern Canada 50° 35° 65° 50°Upper Third of USA 45° 30° 60° 45°Middle Third of USA 40° 25° 55° 40°Lower Third of USA 35° 20° 50° 35°Central Mexico 20° 5° 35° 20°

Equatorial Zone Do not set the array horizontal (0°), or dust and debris will accumulate.

Page 9: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

9

5 ELECTRICAL INSTALLATION

5.1 Controller, Disconnect Switch and Conduit

WARNING To be installed, connected and serviced by qualified personnel only. Ensure all power sourcesare disconnected when making connections to the controller. Follow all appropriate electrical codes. Thereare no user serviceable parts inside the motor or the controller.

Location Place the controller close to the solar array, not the pump. This will reduce the risk of lightning damage.

Explanation — The controller’s input circuitry is more sensitive to surges than the output. It is safest to minimize thelength of the input wiring.

Protection from solar heat Electronic devices are most reliable when they are protected from heat. Thecontroller is thermally protected and will shut off under extreme conditions. Mount the controller in the shade of themid-day sun. An ideal location is directly under the solar array, on the north side of the mounting pole. If shade isnot available, cut a piece of sheet metal and bolt it behind the top of the controller. Bend it over the controller toprovide shade. This is especially important in extremely hot locations.

Position If the controller is to be exposed to the weather, mount it vertically to keep out rainwater. It is preferableto mount it on the north side of a pole or other structure, to help reduce solar heating. This may also allowcomfortable access without hitting one’s head on the array.

Battery system Batteries must be in a cool location for best longevity, and in a protective enclosure forcleanliness and safety. Place the controller near the batteries but NOT in the same enclosure. They must be safelyisolated from the battery terminals and from corrosive gasses.

Mounting method There are 4 mounting holes at the corners of the box. Mount the unit using screws or bolts.

Electrical conduit is recommended We urge you to use electrical conduit (pipe) to protect outdoor wiring fromthe weather, from human activities, and from chewing animals. See photos on the following pages. If you don’t useconduit, use sealed strain-relief cable connectors where cables enter the controller and disconnect switch. Rubberplugs are supplied with the controller to seal any holes that you don’t use.

CAUTION If electrical conduit is to be used, be sure the top of the controller can be easily raised. While thebottom plate is fixed to the conduit, you will need to lift the box for access to the terminals. Leave about 6” (150mm)clearance above the box.

POLE MOUNTED ELECTRICAL ASSEMBLY — SEE PHOTOS on the following pages

The controller can be mounted onto the solar array support pole using ordinary materials available from your localelectric supply store. The photos show a professional system that is easy to assemble. It makes the wiring easy,and allows easy access for testing. These are American style electrical parts. Outside of North America, styles andsizes vary.

HELPFUL HINTS1. You will need two standard screwdrivers to tighten the controller terminals: 1/8” (4 mm) and 1/4” (8 mm).2. The controller does not have space to bend large pump wires. Install a junction box as shown in the photos.

This allows plenty of space to manage excess wire when you close the controller. Cut holes in the box asshown in the photos.

3. If your pump wires are #8 (6 sq. mm) or larger, you can join them to smaller wires in the junction box. #12 (4 sq.mm) or larger is acceptable for this very short length. Use stranded wire for flexibility.

4. If you can’t get a wire into a controller terminal, PUSH the screw in. That will open the terminal. Do NOTremove the screw.

5. After tightening screw terminals, pull the wires hard to confirm that they are secure.

Page 10: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

10

PHOTOS

Professional electrical assembly on the solar arraymounting pole. This uses all standard Americanelectrical components. A 4” pole is shown.

It is preferable to mount controller on the north side ofthe pole, to reduce solar heating.

Controller israised for

wiringaccess.

This junction boxprovides space for

pump wires when thecontroller is closed.

You can join largepump wire to smaller

wire here, for the shortdistance to the

controller.

Arraydisconnect

switch

Conduit for pumpcable

Conduit for floatswitch cable

Ground rod

Solar arraymounting

pole Flexibleconduit tosolar array

Page 11: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

11

PHOTO ABOVE — Parts used in pole-mount assemblyclockwise from top:PVC outdoor rigid conduit (1 1/4” to hold pump wires)PVC outdoor rigid conduit (1/2” for float switch cable, optional)Ground rod (copper-plated steel, 8 feet long)Flexible outdoor conduit (1/2”) with threaded adapters2 hose clamps to hold the flexible conduit (up the pole to the array)4 conduit clamps to fit the mounting pole (4” shown here)Conduit clamp to fit the float switch conduits (1/2”)7 each—bolts, nuts, flat washers, lock washers (1/4” and 5/16”)Conduit male thread adapter (1/2”), lock nut, 3/4X1/2” reducing washers3 conduit male thread adapters (1 1/4”), lock nut (1 of 3 shown)Ground rod clampSolderless lug for controller grounding (AL/CU rated)Slotted strut (Unistrut) cut to lengths: 14” (2) and 8” (3)Junction box (6” X 6” X 4” PVC) is not shown

PHOTO RIGHT — Internal parts of thecontroller, showing rubber plugs in theconduit holes.

Page 12: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

12

5.2 Grounding and Lightning Protection

WARNING Failure to install and connect an effective grounding system will greatly increase the risk oflightning damage and will void your warranty. We suggest you wire the grounding system FIRST.

Experience has taught us that surges induced by nearby lightning are unlikely to damage a solar pump system ifthese instructions are followed. A properly made discharge path to ground (earth) will discharge static electricitythat accumulates in the above-ground structure. This helps prevent the attraction of lightning. When there is anearby lightning strike, a well-grounded structure diverts the surge AROUND the power circuitry, greatly reducingthe probability or the intensity of damage. The ETAPUMP controller has built-in surge protectors that functionONLY if it is effectively grounded.

System Wiring Diagram If your pump was purchased as part of an ETAPUMP INTEGRATED SYSTEM™, aSystem Wiring Diagram should be attached at the back of this manual.

Bond (interconnect) all the metal structural components and electrical enclosures Interconnect the PVmodule (solar panel) frames, the mounting rack, and the ground terminals of the disconnect switch and thecontroller, using wire of minimum size #8 (6mm2), and run the wire to an earth connection. When connectingdissimilar metals, use connectors that are approved for the materials involved. Example: at the aluminumframework of the solar array, use connectors labeled “AL/CU”. This will reduce the potential for corrosion.

Ground connections at the controller The controller has two ground terminals on the inside. They are bothconnected in common with the aluminum enclosure box. Ground connections to the controller can be made to oneor both of the internal ground terminals, or to the box—whatever is expedient.

Ground connections to aluminum Connections to aluminum must be made using terminal lugs that have analuminum-to-copper (AL/CU) rating, and stainless steel fasteners.

Earth connection – Create an effective discharge path Install one or more 8-foot (2.5m) copper-plated groundrods, preferably in moist earth. Where the ground gets very dry (poorly conductive), install more than one rod,spaced at least 10 feet (3m) apart. You can also bury #6 (16 sq. mm) or double #8 (10 sq. mm) or larger BAREcopper wire in a trench at least 100 feet (30m) long. Connect one end to the array structure and controller. Or, cutthe ground wire in half and spread it in two directions. Think of this as a “drain field“ for electrons. If a trench is to bedug for burial of water pipes, ground wire can be run along the bottom of the trench. If you have a steel well casingnear the array, you can use it as a ground rod. Drill and tap a hole to make a strong bolted connection to thecasing. Cemented footers of a ground-mounted array will NOT provide adequate grounding.

Grounding the pump ETAPUMP requires four-conductor (four-wire) cable between the controller and the pump.Three wires carry power and one conducts ground to the motor case. Connect the ground wire to a groundconnection in the controller or to the controller enclosure. This helps to prevent shock if there is a fault in the motor.

CAUTION If the pump is not grounded, the low-water shutoff will not function.

Float switch cable A long run of control cable to a float switch can pick up damaging surges from nearbylightning. The best protection is to use shielded, twisted-pair cable (Dankoff Solar Item #10326). Shielded cablehas a metallic foil or braid surrounding the two wires. Ground the cable shield at the controller end only, not atthe float switch.

Additional lightning protection The ETAPUMP controller has built-in surge protection devices. Additionalgrounding measures or surge protection devices are recommended under any of the following conditions:

1. Isolated location on high ground in a severe lightning area2. Dry, rocky, or otherwise poorly conductive soil3. Long wire run (more than 100 feet / 30m) from the controller to the wellhead, or to the float switch.

NOTE about grounding power conductors For a solar-direct system, the best lightning protection results fromNOT grounding the positive or the negative of the solar input. If system grounding is required by your local electricalauthority, connect the PV array negative to a ground terminal in the controller and switch only the positiveconductor in the array disconnect switch. This may increase the risk of lightning damage.

Page 13: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

13

5.3 Solar Array Wiring

WARNING: Your photovoltaic array generates hazardous voltages. A 48 Volt (nominal) array can generatenearly 100 volts when disconnected from load. A short circuit or loose connection will produce an arc thatcan cause serious burns. All wiring must be done by qualified personnel, in compliance with local, state,and national electrical codes.

The solar array can produce hazardous voltage even under low light exposure. To prevent shock hazard whilewiring the array, leave one or more wires disconnected or cover it with opaque fabric.

ETAPUMP solar-direct (non-battery) systems use a variety of array configurations. Some use 12V (nominal) andsome use 24V modules. Modules are connected in series for 36 or 48V, and sometimes also in parallel to increasethe current. Refer to the System Wiring Diagram at the end of this manual. Be sure the modules (panels) match thedescription on your System Wiring Diagram.

Solar module connections The terminals in the module junction boxes can be confusing. Refer to the modulemanufacturer’s instructions that are packed with the modules. Make strong connections that will hold for manyyears. Most array failures are caused by loose or corroded connections.

PHOTOS show two types of PV module junction systems.

LEFT: Quick-connect system using “MC” connectors.

RIGHT: Conventional junction box with conduit holes.

Type of wire Use either electrical conduit or outdoor UV-resistant wire. The solar array has a life expectancybeyond twenty years. Don’t degrade it with inferiormaterials! Use minimum wire size #12 (4 sq. mm) for theconnections between modules and for short distances tothe controller. Some appropriate types of wire are: USE, UF, SE and SOOW.

Solar tracker wiring If you are installing a solar tracker, pay careful attention to the wire section that leads fromthe moving rack down to the stationary mounting pipe. Use materials that are suitable for highly flexibleapplications, and leave some extra length to form a drip loop that will shed water and minimize stress. Secure theassembly mechanically at each end so the insulation and the connections are not stressed by the tracker’s motion.Swing the tracker fully in each direction, at various seasonal tilt angles, to verify that the cable does not rub orrestrict the tracking motion. See tracker photo.

MC connectors Some PV modules have these quick connectors. If the connector is not appropriate at somejunctions, it is acceptable to cut the wire and make a conventional connection.

Page 14: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

14

5.4 Solar Array (PV) Disconnect Switch

For solar-direct systems, a two-pole disconnect switch must beinstalled between the solar array and the controller. Switch it offto prevent shock and arc burn hazard during installation andmaintenance, or if the system will be shut down for the season.

The photo shows the PV Array Disconnect Switch that isincluded with the ETAPUMP Integrated System™ (DankoffSolar Item #11430).

Overload protection (fuse or breaker) is NOT required in the PVcircuit. However, we have not found a UL-listed switch ofsufficient DC rating that does not hold fuses. Install fuses withany rating between 20 and 30 amps. They are NOT expected toblow during a fault. Type FRNR or FLNR fuses have sufficientDC ratings. Copper buss bar replacements can be used insteadof fuses.

Explanation – Overload protection is not required in the arraycircuit, for two reasons. (1) Short circuit current from the solararray can never reach the ampacity (maximum safe capacity) ofthe recommended wire, and (2) the ETAPUMP controller hasinternal overload protection.

CAUTION Loose connections are the most common cause of system failures. Pull on each connection to confirm that it is secure.

5.5 Controller Input Wiring

Refer to the System Wiring Diagram at the end of this manual.

WARNING TEST THE VOLTAGE before connecting power to the controller. Voltage (open circuit) must notexceed 90V. (In cloudy weather, the open circuit voltage will be near maximum.)

WARNING Some thin-film modules (panels) may produce excessive voltage, especially when they arenew. If the open circuit voltage exceeds 90V, DO NOT connect power to the controller. Contact yoursupplier. (ETAPUMP Integrated System™ does not use this type of module.)

WARNING Observe polarity (+ and –). Reverse polarity at the controller input will blow an internal fuse.The fuse is located on the circuit board behind the POWER IN terminals. A spare fuse is taped inside the box.

WARNING Do not apply a direct connection or an amp meter between + and – at the controller input. Ashort circuit at this point will damage the controller.

WARNING SOLAR-DIRECT systems only — Do not connect any electrical load or device to the solar arrayif it is not part of the ETAPUMP system. Connection of a battery charger, electric tracker controller, electric fencecharger, or other load simultaneously with ETAPUMP will “confuse” the controller and prevent proper operation.

from PV+ –

+ –to controller

Page 15: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

15

Ensure that the controller’s ON/OFF switch is in OFF position and that the solar array disconnect switch (or batteryfuse or circuit breaker) is also OFF. Connect the power from the solar array to the disconnect switch, then to thecontroller. Observe polarity. If your wires are not clearly marked +/–, test them using a DC voltmeter or multitester.

PHOTO EP600 solar-directcontroller terminals

RPM Setting is shown in normal,maximum position (fully clockwise)

5.6 Maximum RPMSetting

This setting is only present on solar-direct (non-battery) controllers. TheMax. RPM Setting knob is locatedinside the controller, to the right of theterminals, as shown in the photo

above. It limits only the MAXIMUM flow rate. It sets a limit to the pumping rate under maximum sunlightconditions. It will NOT reduce the ability to start or the performance in low sunlight.

Reasons to reduce the maximum RPM1. To prevent over-pumping a limited water source (see Section 6.7)2. To limit the back-pressure (and prevent possible pump overload) when pumping into a direct-pumped irrigation

system, a filtration system, or an undersized pipeline3. Model ETA-107C, or any system that stops from overload during full sunlight

WARNING For model ETA-107C or any other model that comes with a warning requiring this adjustment,you are required to reduce the setting to position 2. If this is not done, the system may stop during full-sunconditions, due to power overload.

ILLUSTRATION Position 1 is the normal factory setting, to allow maximum pump performance formost pump models. Position 2 is the required setting ONLY for model ETA-107C, to preventoverload.

ADD PHOTO XXXXXXXXXXXXXXXXXXXXXXXXXX

Wiring a battery system controller Wiring the ME24/48 battery system pump controller is similar to the solar-direct model, except that you must install a jumper wire if the battery voltage is 24V.

Select the voltage (24 or 48V) A jumper wire must be installed for 24V systems (#12 wire, minimum). A shortpiece of wire is taped inside the controller for this purpose.

PHOTO ME24/48 battery system controller terminals

1

2

Page 16: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

16

5.7 Submersible Pump Cable and Splice

Selection of cable Use only an approved type of submersible pump cable, the same type that is used forconventional AC pumps. It is available from your local water well supplier or from your ETAPUMP supplier. Youneed 4-conductor cable. It is often called “3-wire-with-ground” because it has 3 power wires and a ground wire. Todetermine the minimum required wire size, refer to the ETAPUMP Systems Sizing Table.

Submersible Splice A splice kit is included with ETAPUMP Integrated System™. It includes crimp connectors tojoin the copper wires, adhesive heat-shrink tubing, and instructions. If the drop cable wire is too large to fit in thecrimp connector, cut off some of the wire strands to make it fit. Use a standard crimping tool, then observe that thewires are held very securely.

PHOTO – Submersible cable splice, before protective tape is applied

When the heat-shrink tubing is heated, it shrinks and the adhesive melts and bonds to the wires. Each wire must besealed 100% water-tight. After this is complete, wrap tape around the entire splice, to give mechanical protection. Itis NOT necessary to provide a water-tight seal around the outer jacket of the cable. If you make a mistake or loseyour ETAPUMP splice kit, you can obtain a submersible splice kit from any pump supplier.

5.8 Wiring Order for Correct Rotation

WARNING If the pump wires are in the wrong order, the motor will run in reverse and the pump will notfunction. Damage may result if the pump is run in reverse for a long period. Check the direction BEFOREinstalling the pump. The proper direction is COUNTER-CLOCKWISE when viewed from above.

WARNING If you run the motor dry WITH the pump end installed, do not run it dry for more than 10seconds. If the pump end is NOT installed, the motor can be run dry without harm.

The power wires on the pump are black with white lettering toindicate L1, L2 and L3. WRITE DOWN the colors that yousplice to L1/ L2 / L3 so you can match them with the L1/ L2 / L3terminals in the pump controller.

If your pump cable has the colors shown below, you canuse the following sequence as your standard:

RED BLACK YELLOW GREEN L1 L2 L3 Ground

If you did not write down the color match (or the wind blew yournote away) connect the three power wires to the controller inANY order (random). Apply power and turn the controller on.Observe the pump shaft rotation, then turn the power off. If thedirection is wrong, exchange ANY TWO of the power wires at

motor leadercable

wires spliced with adhesiveheat-shrink tubing

drop cable

MOTORROTATION

Page 17: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

17

the controller. In any case, when you are finished connecting the pump to the controller, test it to assure the properdirection.

Question The motor shaft is hard to turn by hand, and moves in a bumpy manner. Is this normal?Answer YES. This is caused by permanent magnets in the motor. It is especially hard to turn when it isconnected to the controller, or if the three power wires are connected together.

Did you install the pump in the well without checking the wiring order or the direction?OR – Is it running but very noisey or not pumping properly?

If your pump model number contains “C” it has a centrifugal pump end. If it runs in reverse, it willproduce a reduced amount of pressure and may produce little or no flow. This will NOT damage the pump.

If your pump model number does NOT contain “C” it has a helical rotor (positive displacement) pumpend. If it runs in reverse, it will try to pump downward. You will here a loud vibration as it comes up to speed(due to cavitation). Turn off the pump immediately! Reverse the direction. If it is much quieter, that shouldfix it. (In reverse, the pump will run dry. If the pump is new from the factory, it is lubricated with temporary(non-toxic) grease so it can run dry for about 90 seconds without damage. If the pump is not new, it mustnot be run for more than about 15 seconds.

5.9 Low-Water Probe for Dry-Run Protection

The purpose of the low-water probe is to sense the loss of water just above the pump,so that the pump will shut off and not run dry. Running completely dry will damage thepump end and void the warranty. For shipment, the probe assembly is packed with yourETAPUMP controller.

Install the probe either above or just below the check valve at the pump outlet. Splice itswire to a single-conductor submersible wire of #18 AWG or larger, using the materialsin your splice kit. The splice uses heat-shrink tubing, same as your main pump splice(see splice kit instructions). In the controller, connect the well probe wire to the wellprobe terminal.

CAUTION The well probe must not make contact with any other metal parts.

Operation The probe senses electrical conductivity through the water, between theprobe and the metal body of the pump. If the water level drops below the probe,continuity is lost. The controller will stop the pump and the “Low-Water OFF” light willindicate. The controller will attempt to restart the pump automatically after a delay of 30-35 minutes. To force it to restart, turn the controller off for two seconds, then on again.

The Low Water-OFF light stays ON for the remainder of the day or until power to the system is interrupted. Itstays on even if the water recovers and the pump restarts. This indicates that the water source ran low at leastonce during the day.

CAUTION For the well probe (dry run prevention) system to work, the pump’s ground wire must beconnected to ground at the one of controller’s ground terminals or the controller’s metal enclosure.

CAUTION If you are not using the well probe, connect a short wire from terminal 1 to ground. If you feelcertain about the reliability of the water source and you choose not to install the well probe, connect the well probeterminal to ground.

WARNING A combination of salty or mineralized (highly conductive) water and a coating of minerals,bacteria or algae may cause failure of the low-water probe to detect a low-water condition. If deposits on theprobe are a problem, consider using a different type of probe or a different way to mount it, to isolate it more fromthe motor. It may help to mount it higher on plastic drop pipe. You can also substitute a float switch if there issufficient space in the water source. Connect one side of the switch to the probe terminal in the controller, and theother side to ground. Or, call your ETAPUMP supplier for advice. You may want to reduce the “Maximum RPM”adjustment (see Section 6.7 Utilizing a Low-Production Water Source).

Page 18: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

18

5.10 Automatic Control For Full-Tank Shutoff

We recommend the use of a float switch or other means to prevent overflow of your tank. This accessory will stopthe pump when the tank is full, then reset when the level drops. This conserves ground water, prevents overflow,and eliminates unnecessary pump wear. You can obtain Float Switch Kit (Dankoff Solar Item # 10320) from yourETAPUMP supplier. The Float Switch Kit includes float switch, cable weight and cable clamp as illustrated.

WARNING The float switch must MAKE contact onrise to turn the pump OFF.

Our pump controllers allow the use of small signal cableto a remote float switch, even if the tank is a longdistance away. Any small 2-wire cable will work, but itmust be suitable for the environment to which it isexposed. If it must run a long distance, use twisted-pairshielded cable to reduce the chance of damage due tolightning-induced surge (Dankoff Solar Item #10326. SeeSection 5.2 Grounding and Lightning Protection.

If you are not using a float switch, leave the floatswitch terminals in the controller disconnected.

Overriding the float switch You may want todisconnect your float switch (1) to allow overflow for irrigation purposes or (2) to test or observe your system. To dothis, install a switch to disconnect either of the two float switch wires. Use any size of toggle switch available froman electronic supply, electrical supply, or hardware store.

Connection to the controller Connect the float switch cable to the two float switch terminals of the controller. Ifyou use shielded cable (containing an outer metallic foil or braid, like Dankoff Solar Float Switch Cable), connectthe shield to ground AT THE CONTROLLER ONLY. Do NOT ground the shield at the float switch. This will helpprotect the system from surges induced by nearby lightning.

Operation When the water level is high, the float switch will MAKE (close) contact to stop the pump. The FULL-TANK OFF indicator on the controller will light up.

Wireless Level Controller eliminates float switch cable This device will provide full-tank shutoff by means of apressure sensor. It eliminates the need to run wires to your tank. It also displays the discharge head (for tank levelmonitoring). It draws its power (<1 watt) from one of the PV modules (solar panels) in your pump system. Orderfrom your ETAPUMP supplier as follows:

For 0-230 vertical feet from wellhead (ground level) up to top of tank: Item # xxxx availableFor 150-460 vertical feet from wellhead (ground level) up to top of tank: Item # xxxx summer 2002

Manual remote control The float switch circuit can be used with a manual switch to turn the pump on and offfrom a distance. Any commonly available on/off switch can be used. Mount the switch upside-down because whenit is in the ON position, it will turn the pump OFF.

5.11 Battery-Based Systems

ETAPUMP using a storage battery system must use controller Model ME 24/48. This controller is designed tooperate from a 24 volt or a 48 volt battery system. DO NOT run it directly from a solar array without batteries, ordamage will result.

WARNING OVERLOAD PROTECTION IS REQUIRED FOR BATTERY SYSTEMS Install a fuse or circuitbreaker between the battery and the pump controller. Locate it close to the power source. This will protect thebattery, the wiring, and the controller, in case of a short circuit or overload. For either a 24V or 48V system, use a10 amp time delay (slow blow) fuse or breaker. During startup, the DC current draw will be 20 amps for about 1second or less. A slow-blow fuse or a standard DC circuit breaker will handle this short-term starting load.

OFF

ON

sealed cable clamp

cable weight

pumping range

WATER STORAGE

TANK

FLOAT SWITCH

Page 19: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

19

Wire Sizing for the DC circuit Wire must be sized for no more than 5% voltage drop at 20 amps. Size isdependent on wire length. Refer to a 24V or 48V wire sizing chart as appropriate.

CAUTION ME 24/48 controller does NOT have a low-voltage disconnect function. If the voltage of a lead-acidtype battery falls below 21V (24V system) or 42V (48V system), permanent battery damage will result. It is theresponsibility of the installer to provide a suitable low voltage disconnect (LVD) system. LVD function is built intomany solar charge controllers and is also available as a separate device. Most LVD devices will not reset until thebattery re-gains a substantial charge. This can take hours of charging time. Be sure the operator of the systemunderstands LVD function.

ME 24/48 Controller is a motor controller. It is NOT a charge controller. A conventional charge controllershould be a part of any renewable energy battery charging system, to prevent overcharge. If you have questionsabout battery charge control or low voltage disconnect, contact the supplier of your power system. Be sure yours issuitable for the type of batteries you have. (Sealed batteries must use a lower voltage setting than liquid-filledbatteries.)

5.12 Pressurizing Systems

ETAPUMP is appropriate for automatic water pressurizing when powered by a battery system. If you are raisingwater vertically AND pressurizing, note the relationship: 2.31 ft. = 1 PSI. Example: A pump that lifts 100 verticalfeet and pressurizes to 60 PSI must pump the equivalent of 240 feet. Be sure your pump was chosen correctly foryour application. The installation is the same as for a conventional AC pump, with the exception of the powerswitching.

WARNING A reverse action pressure switch is required. Do not use a conventional pressure switch. Donot switch the controller’s primary power. The pump will not start reliably in this mode.

Pressure switch (reverse action) A pressure switch is required to turn the pump on when the pressure is low(the cut-in pressure) and off when it is high (the cut-out pressure). ETAPUMP uses its FLOAT SWITCH terminalsfor pressure switch control. The float switch circuit uses “reverse logic” – making contact will STOP the pump. Youmust use a REVERSE ACTION pressure switch (Dankoff Solar item # 20222, set at 20/40 PSI, adjustable to 65PSI max.). It can be wired using very small wire (#18 AWG minimum) regardless of the distance between thecontroller and the switch.

CAUTION Label the pressure switch “reverse action” to avoid confusion in the future.

If you wish to obtain the reverse action switch locally, it is Square-D model 9013FRG-2J23 adjustable to 65 PSI(Grainger catalog #5B416) or model 9013FRG-62J23 adjustable to 100 PSI (Grainger catalog #1V630).

WARNING INSTALL A PRESSURE RELIEF VALVE. If the pressure switch fails, this will prevent extremepressure from bursting the tank or piping and causing a flood.

Pressure relief valve Install the valve near your pressure tank. Purchase a 1/2” (or larger) valve that is set in therange of 25-75% higher than the cut-out pressure. Run a pipe or hose from its outlet to a drain or to the outdoorswhere water can drain away safely. When the system is operating, watch the valve to verify that it does not leakunder normal conditions.

Pressure tank A pressure tank is required. We recommend a captive-air pressure tank of 40 gallons (150 liters)or more, to avoid rapid on/off cycling and to add some reserve supply. The air bladder in the tank must be properlypre-charged to function in your system. If pre-charge is set too high, the pressure tank will be of little or no benefit.

How to pre-charge a captive-air pressure tank Follow the instructions that came with the tank, or do as follows:1. Make note of the cut-in setting of the pressure switch.2. Turn off the pump and exhaust the water from the tank, so the water pressure is 0.3. There is an air fitting on top of the tank. This allows you to pressurize the rubber bladder in the tank (like a

balloon). Measure the air pressure in the tank using a tire gauge. Adjust the pressure to 2 or 3 PSI (.15-.2 bar)LESS THAN THE CUT-IN PRESSURE.

4. If you readjust the cut-in setting of the pressure switch, remember to adjust the pre-charge too.

NOTE If power to the controller is disrupted, you will need to switch the controller off, then on again for it to restart.

Page 20: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

20

6 PREPARING TO INSTALL THE PUMP

6.1 Pump End to Motor Assembly

After you have confirmed that the motor runs in the proper direction,mount the pump end to the motor. Be sure the matching surfaces arefree of dirt. Set the pump end down onto the motor with the groovepositioned around the motor cable. Make sure the shaft couplingengages properly, as shown in the photo.

Fasten the pump end to the motor with the four nuts and lockwashers provided. Tighten the nuts securely.

ETAPUMP models without a “C” in the model number (mostmodels) have two setscrews in the pump shaft coupling. In that case,tighten the screws with the 3mm Allen (hex) wrench provided.

Explanation—The purpose of these screws is to prevent the couplingfrom rising up off the motor shaft if the motor is accidentally run inreverse, or when the pump is initially installed at a high depth ofsubmergence.

Pumps with a “C” in the model number have no setscrews. Theydo have a cable guard, not shown in this photo. Mount it to the pumpwith the screws provided.

6.2 Drop Pipe

Type of pipe ETAPUMP can be installed using the same pipe materials as conventional submersible pumps.ETAPUMP produces a smooth flow (no pulsation). It starts slowly, without sudden torque. Thus there is no need forflexible (damping) pipe or a torque arrestor. Use any suitable rigid pipe or flexible pipe.

Size of pipe ETAPUMP systems use the same pipe-sizing criteria as conventional pump installations.Undersized pipe will reduce the performance of the system. Pipe size is based on the maximum flow rate and theTOTAL length of pipe from the pump to the pipe outlet or tank. Refer to the pump specifications at the end of thismanual to determine the peak flow rate for the system you are installing. If a long run of pipe is required, it mayneed to be larger than the outlet size of the pump. Refer to Section 13.2 Water Pipe Sizing Chart.

Reduced pipe size should be considered in the following situations:1. Sandy water conditions – especially with a solar-direct system that pumps very slowly on cloudy days. Smaller

pipe will increase the flow velocity and help exhaust sand that may accumulate in the drop pipe. (See Section6.6 “Coping with Dirty Water Conditions”.)

2. Hand installation, to reduce the weight and increase flexibility.

Balance these factors against the friction loss that will result from using smaller pipe. You can use a pipe size thatis smaller than the pump outlet by using a reducer bushing. Do not screw a metal fitting into a plastic bushing. Thebushing may crack.

6.3 Safety Rope and Binding

Safety rope can prevent loss of the pump. If pipe breaks, the rope can be used to pull the pump out. Use 1/4”(6mm) water well safety rope. It can be purchased from ETAPUMP supplier (Dankoff Solar Item #10360) or from alocal pump supplier. Polypropylene marine rope is a good substitute. Do NOT use nylon.

shaft couplingwith

setscrews

Page 21: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

21

WARNING Safety rope is for emergency pump removal. It must not be a primary means of support. Make itslightly longer than the drop pipe so it does not bear any weight.

WARNING Do not use nylon rope in water. Nylon absorbs water and weakens after a few years. Failure cancause damage or loss of your equipment. Use polypropylene rope that is sold for water well or marineapplications.

WARNING Plastic rope will weaken from long exposure to sunlight. Secure it inside the well casing toavoid exposure, or substitute stainless steel wire rope.

Safety rope at wellhead Prepare to tie the rope underneath the well seal or well cap. If your well cap does nothave a place to tie the rope, drill a hole in the casing and install an eye bolt. Prepare this detail before you installthe pump! (See Section 13.3 Wellhead Assembly for Drilled Wells.)

Rope exposed to sunlight If the safety rope must be exposed to sunlight, use stainless steel wire rope or chain

Safety rope at the pump Run the rope through both eyelets on the pump and tie a knot

Bind the drop pipe/cable/rope with tape Lay out the pipe, cable, and rope on the ground. Do not twist themtogether. Bind the cable and rope to the pipe every 10-15 feet (3-4m) using vinyl tape. Use either standard (UL-listed) electrical tape (about 6 to 8 turns) or “pipe wrap tape”, which is wider and requires fewer turns. Pipe wraptape is available from water well or electric supply stores. Remember that the pipe will stretch, and the cable willnot. Leave a slight excess length of cable between each wrap.

WARNING Do not use nylon cable ties in water. Nylon absorbs water and gets weak after a few years.Failure can cause damage or loss of your equipment. To bind the pump cable to the drop pipe, use vinylelectrical tape or pipe-wrap tape.

6.4 Installation in a Surface Water Source

This refers to installation in a surface well, spring, pond, lake, river or tank.

Positioning the pump Your pump may be placed in either a vertical or a horizontal position. The intake must befully submerged. To reduce the intake of sediment, do not place the intake very close to the bottom.

River or stream If you install the pump in a river or stream, secure it from logs and debris that may floatdownstream. Use stainless steel wire rope or chain instead of plastic safety rope (plastic rope will weaken insunlight). Consider digging a shallow well near the stream. This will allow filtration of the water through the earth,and will protect the pump from floating debris or human tampering.

No cooling requirement! Unlike conventional pumps, ETAPUMP does NOT require moving water to cool themotor. The high-efficiency motor generates very little heat. There is no need for a flow shroud to force water pastthe motor. (For temperature tolerance, see Section 12.)

Page 22: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

22

6.5 Deep Well Setting — How Deep?

ETAPUMP may be submersed as deep as necessary to ensure reliable water supply. The lift load on the pump isdetermined by the vertical head of water starting at the SURFACE of the water in the source. Increasing thesubmergence of the pump (placing it lower in the well) will NOT cause it to work harder or to pump less water, norwill it increase the stress or wear on the pump.

There are two reasons NOT to set the pump near the bottom of the well (if it isn’t necessary)1. A deep setting will increase the size requirements, costs and weight of pipe and cable.2. A deep setting will increase the chance of sand or sediment being drawn into the pump.

To make an informed decision about setting the pump, it is helpful to have accurate data for your water source. Inmost places, drillers are required to report the details and the performance of wells that they drill. If you do not havethe well record (driller’s log), you can obtain a copy from your regional government office that oversees groundwater resources and issues drilling permits. In USA, it is a state office, typically called Department of NaturalResources or State Engineer’s Office. However, the data may be missing or inaccurate, and conditions can changeover the years. If necessary, you can have the well tested by a water well contractor.

6.6 Coping with Dirty Water Conditions

ETAPUMP has good resistance to quantities of sand and fine silt that can normally occur in a well. However, anyamount of abrasive material will reduce the life of the pump end. Wear from abrasive material is not covered onwarranty. In some cases, sediment may settle from the drop pipe each time the pump stops, and will block the flow.If your water contains high amounts of sand or sediment, follow these instructions.

To avoid pumping dirty water1. Have your well purged or otherwise improved by a water well contractor.2. Temporarily install a larger pump to draw at a high flow rate until silt is purged from the well.3. Set the pump as high as possible in the well. If the pump can be placed higher than the perforations in the well

casing, it will probably avoid all but the finest silt.4. If your water source is a river or stream, dig a shallow well next to the stream to obtain clean water.

If dirty water cannot be avoided1. Use a reduced size of drop pipe. This will maximize the velocity of water flow in order to exhaust sand particles.

Refer to Section 13.2 Water Pipe Sizing Chart. Select the smallest size pipe that does not impose excessivefriction loss. Use a reducer bushing on the pump if necessary, to adapt it to a smaller pipe size.

2. Monitor the situation occasionally by observing the rate or the daily volume of water pumped. As a pump wears,its flow rate will decrease gradually (so will the current draw). Replace the pump end when reducedperformance is observed, or before your season of greatest water demand.

Question What effect does hard, mineralized, alkaline or salty water have?Answer Generally, none. Dissolved minerals and salts are not abrasive. If hard mineral deposits accumulate onthe intake screen (in an extreme case) it may need to be cleaned.

Page 23: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

23

6.7 Utilizing a Low-Production Water Source

ETAPUMP is can make the best of a limited water source, even if the pumping rate can exceed the recovery of thewell. You want to draw the most water possible, but you do not want the pump to run dry. ETAPUMP can handlethis situation in two ways.

1. The low-water probe The low-water probe (included with ETAPUMP) allows the pump to work to its fullpotential until the water level drops (see Section 5.9). This is a good strategy because you get all the water you canbefore the sun is possibly disrupted by clouds. Place the pump near the bottom of the well to utilize the storage ofwater in the well. When the pump is stopped by the low-water probe, it re-starts after a 30-35 minute time delay.The Low Water OFF light will stay on even after the water recovers and the pump restarts, to indicate that the levelgot low at some time during the day. See Section 5.9 Low Water Probe.

2. Reduce the Maximum RPM setting If the well has little storage capacity, the supply may recover before thepump restarts. In this case, reduce the Maximum RPM setting in the controller (solar-direct systems only). SeeSection 5.6.

WARNING Do not use a valve as a means of reducing the flow. With a helical rotor pump, excessive pressuremay result. Use the Maximum RPM setting instead.

Question How is a pump damaged from “dry run”?Answer Water is the lubricant for the moving parts. As long as water is trickling into the pump, it will provideenough lubrication to prevent damage.

6.8 Installing the Pump Under a Windmill Cylinder

ETAPUMP can be combined with a classic water-pumping windmill, to utilize both wind and solar energyautomatically. The following system is often used with a conventional AC pump, so a generator can be used forbackup. A windmill cylinder normally has pipe threads at the intake (on the bottom). The AC pump is placedimmediately below the cylinder, and piped right into the cylinder. When power is applied to the AC pump, it pusheswater up through the cylinder (pushing its valves open) with little resistance. When the windmill draws water, itsucks it up through the AC pump with little resistance. (The centrifugal pump end of the standard AC pump allowswater to flow through it when it is stopped.) When both pumps operate, each one is relieved of its load, more orless. This system can be employed with ETAPUMP but for helical rotor models, the following warning applies.

WARNING ETAPUMP helical rotor models (those without a “C” in the model number) will NOT allow waterto flow freely when stopped. A bypass foot valve assembly must be used.

To use a helical rotor ETAPUMP under a windmill cylinder, you must build a bypass assembly with a T fitting and afoot valve (a check valve with an intake screen). When the windmill’s flow exceeds that of the solar pump, water issucked in through the foot valve directly into the cylinder. When the solar pump’s flow exceeds that of the windmill,the foot valve will close and allow the solar pump to work normally, pushing up through the cylinder (and its internalvalves) with almost no resistance.

Copper fittings must be used for the bypass assembly due to the limited space in the well casing. To make thissystem for a casing smaller than 6” (150 mm) an offset using 45° elbows must be carefully constructed. Do not useany iron fittings in this assembly.

An ETAPUMP centrifugal model (one with a “C” in the model number) will allow water to flow freely through it anddoes NOT require a bypass assembly.

Page 24: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

24

7 IN-WELL ASSEMBLY AND INSTALLATION

SEE REFERENCE SECTION At the end of this manual (Section 13) you will find instructions for wellheadassembly, water storage, control and monitoring of water supply, pipe sizing, freeze protection, and more.

7.1 Rubber Spacers (Models –07 and –14 only)

This applies ONLY to models ETA-07 (HR-07 pump end) and ETA-14 (HR-14 pump end)

Helical rotor pumps vibrate due to the eccentric rotation of the helical rotor. This is normal. Rubber spacers reducethe vibration that may be transferred to the well casing. Models –03 and –04 vibrate only slightly so they are notsupplied with rubber spacers.

PHOTO LEFTThese helical rotor models do NOT have rubber spacers

ETA-03 (HR-03) ETA-04 (HR-04) ETA-04H (HR-04H)

PHOTO RIGHTThese models have rubber spacers

ETA-07 (HR-07) ETA-14 (HR-14)

Clearance for drilled well casings Rubber spacers fit a 6” (150 mm)inside-diameter or larger well casing.

Cut the rubber spacer legs shorter if you are installing the pump in asmaller well casing. Grooves indicate where to cut for a 4” (100 mm)casing. Use a fine-tooth saw to cut the rubber.

WARNING The threads in the check valve require an adhesivesealant. They are not tapered pipe thread. Normally, there is noreason to remove the check valve. If you do remove it, use ahardening adhesive pipe sealant when you replace it.

7.2 Machine Installation

If you are professionally equipped to install conventional AC submersible pumps, you can use the same equipmentand methods for ETAPUMP. ETAPUMP has no special pipe requirements. You can use any suitable rigid orflexible pipe. See Section 6.2 Drop Pipe, and Section 13.2 Water Pipe Sizing Chart.

Page 25: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

25

7.3 Hand Installation

WARNING Hand installation can be hazardous. There are potential hazards in handling any heavymechanical assembly. We do not encourage hand installation or removal except in shallow-watersituations. If you have any doubts about your ability to install or removal a pump safely and economically,hire a professional pump service contractor!

Before considering installation or removal by hand, calculate the weight of the system (with water in the pipe) andmake sure you have enough people to help. If you have any doubts about the safety or feasibility, hire aprofessional pump service contractor.

Example of cable weight — #10-4 submersible cable weighs approximately 25 lbs. per 100 ft. (40 kg per 100m).Each larger size (smaller AWG#) weighs approximately 30% more.

Weight of water in a pipe (lbs.) = pipe diameter (inches)2 X 0.34 X length (feet)Example: Water in 100 feet of 1” pipe weighs about 34 lbs.

Polyethylene pipe (black rolled pipe) Polyethylene (PE) is often used for solar pumps that are installed byhand, especially in remote areas that are not accessible to a pump service truck or where transportation of rigidpipe is difficult. You can expect good results if you follow these warnings.

WARNING Follow these precautions when using polyethylene (PE) pipe.1. In North America, most professional pump contractors do NOT have the equipment to pull PE pipe. Their

equipment is designed for rigid pipe in 21’ joints. Do not use PE pipe unless you can be prepared to handle itstotal weight (full of water) in the future, in pump service is required.

2. Do not exceed the pressure rating of the pipe. The most widely available PE pipe has a maximum pressurerating of 100 PSI (7 bar). This is equal to 230 feet (70m) of total vertical lift.

3. Use only threaded adapters that are designed for the pipe you choose. Do not use galvanized steel adapters.They will rust through.

4. Do not use any sealing compound with PE pipe adapters.5. If you use insert adapters with hose clamps, use TWO clamps at each adapter. Tighten the clamps with a

wrench, not just a screwdriver. Use “all stainless” hose clamps. (Automotive clamps have carbon steel screwsthat will rust and fail.)

6. Have some extra hose clamps on hand in case you strip one.7. Have an extra coupling on hand in case you bend the pipe too sharply (kink it) and make a weak spot.8. PE pipe will stretch about 1%. Make the electrical cable and safety rope about 1.5% longer than the pipe so

when the pipe stretches, the cable and splice will not be stressed.

WARNING DO NOT USE A ROPE WINCH to install or remove a pump in a drilled well casing (borehole).If you use a winch to pull the pump by winding up rope or wire rope, the electrical cable can slip down the pipeand/or the pipe can collapse. If the pipe or cable jams and gets wedged in the casing, you can lose your equipmentand even permanently block the well! Some installers use a winch with a reel of about 3 feet (1m) diameter orlarger, to pull flexible pipe. This is ideal if you have the equipment and experience to do the job safely.

WARNING DO NOT USE A VEHICLE to install or remove a pump. During removal, the pump can catch onjoints or edges in the well casing. Damage or loss of the pump can occur before the vehicle operator can react.

7.4 Sanitizing the Well

Sanitizing a well will kill bacteria that may have been introduced during the pump installation. This can be done withchlorine bleach or a dry chlorine compound poured down the well just before or just after a pump is installed.Consult a local supplier or environmental health authority for a recommended procedure. ETAPUMP will not bedamaged by normal quantities of chorine compound.

Page 26: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

26

8 OPERATING THE ETAPUMP (Solar-Direct)

PHOTO – Control panel

The control panel is located at the end of the controller (generally the bottom) where the wires enter.

INDICATOR LIGHTS

System ON green The system is switched on and solar array voltage is present Pump ON green Motor is running Tank FULL / OFF red Connection is made between the float switch terminals, pump is offWater Source LOW / OFF red Low-water probe is out of the water (or its connection failed).

After the water level recovers, the light will stay on for the remainderof the day (or until power is interrupted). This will inform you thatthe water source ran low at least once during the day.

Starting the pump Be sure there is not a closed valve or other obstruction in the water line! Switch on the arraydisconnect switch and the power switch on the controller. Leave the switches on at all times, unless you desire tohave the system off.

The pump should start under the following conditions1. clear sun at an angle of about 20° or more from the surface of the solar array2. cloudy conditions, if the sunshine is bright enough to cast a slight shadow3. low-water probe submersed in the water source (or bypassed in the controller)4. full-tank float switch in low (break) position (or no connection in the controller)

When sunshine is insufficient When sunshine on the array is too weak for the pump to run, it will attempt tostart about every 90 seconds. During each attempt, you will hear a slight noise in the controller.

When pump runs slowly (Pump ON) under weak sun conditions1. ETAPUMP models that have “C” in the model number – These use a centrifugal pump end. In weak sun, the

pump may spin without lifting water all the way to the outlet. This is normal.2. ETAPUMP models that do NOT have “C” in the model number – These use a helical rotor (positive

displacement) pump end. If the pump is turning, even slowly, water will be delivered at a slow rate.

When pump stops from a sudden shadow on the solar arrayIf a shadow suddenly passes over the array, like if you walk in front if it, the controller may get confused by therapid voltage drop. It may make rapid on/off noises and a high-pitched noise, then stop. This does NOT indicate aproblem. The pump will attempt to start again after the normal delay.

Page 27: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

27

Time delays1. After pump stops due to insufficient sunshine or overload fault – 90 SECONDS or less2. After full-tank float switch resets – 20 SECONDS or less3. After low-water probe regains contact with water in the source – 20 MINUTES

To force a quick startTo test or observe the system, you can bypass the normal time delays. Switch the on/off switch (or the powersource) off for 2 seconds, then on again. The pump should start immediately if sufficient power is present.

When there is NO load on the motorIf the motor is tested without the pump attached, it will run for about 40 seconds, then it will stop. This is thecontroller’s normal response when there is no load on the motor.

8.1 Normal Noise and Vibration

Controller noise As the pump starts, you may hear slight high-pitched noises from the controller. This is normal.

Pump vibration Most ETAPUMP models use a HELICAL ROTOR pump end (those that do NOT have a “C” inthe model number. Some vibration is normal with these pumps, especially at slow speed. Model ETA-14 (HR-14)vibrates the most, because of its large rotor. If this is disturbing, try changing the pump’s position. If the pump isextremely noisy and not pumping water, the motor may be running in reverse. This is only possible if it was justinstalled or reconnected (see Section 5.8).

ETAPUMP models that have a “C” in the model number use a CENTRIFUGAL pump end similar to conventionalpumps. They produce no significant vibration.

Page 28: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

28

9 TROUBLE SHOOTING

If you have trouble, please read this section before calling for help.

If you call for help, please refer to the model and serial numbersof your pump and your controller or your ETAPUMP Integrated System™.

See SYSTEM REPORT, page 3.

We suggest that you obtain a MULTIMETER to make electrical measurements.See Section 13.7 Obtaining and Using a Multimeter

9.1 If the Pump Doesn’t Run

Most problems are caused by wrong connections (in a new installation) or failed connections, especially where awire is not secure and falls out of a terminal. Please follow these instructions before calling for help.

The System ON light will indicate that system is switched on and power is available. This indicates that theconnection to the power source is probably correct. It indicates that VOLTAGE is present. There may not besufficient power behind it to start the pump, but it should make starting attempts about every 90 seconds.

Pump attempts to start every 90 seconds but doesn’t runThe controller makes a slight noise as it tries to start the pump. The pump will start to turn or just vibrate a little.

1. There may be insufficient power reaching the controller. A solar-direct (non-battery) system should start ifthere is enough sun to cast a slight shadow. A battery system should start if the supply voltage is greaterthan 22V or 44V.

2. If the pump was recently connected (or reconnected) to the controller, it may be running in reversedirection. See Section 5.8.

3. If the motor shaft only vibrates and will not turn, it probably has power on only two of its three wires. Thiswill happen if there is a broken connection or if you accidentally exchanged one of the power wires with theground wire. See Section 9.3, testing the motor circuit and the controller output.

9.2 Inspecting the System

Many problems can be located by simple inspection. No electrical experience is required for these steps.

Inspect the solar array1. Is it facing the sun? (See solar array orientation, Sections 4.4 and 4.5)2. Is there a partial shadow on the array? If only 10% of the array is shadowed, it can stop the pump!

Inspect all wires and connections1. Look carefully for improper wiring (especially in a new installation).2. Make a visual inspection of the condition of the wires and connections. Wires are often chewed by animals

if they are not enclosed in conduit (pipe).3. Pull wires with your hands to check for failed mechanical connections.

Inspect the controller1. Remove the screws from the bottom plate of the controller. Move the plate downward (or the controller

upward) to reveal the terminal block where the wires connect. (See Section 5.5.)2. First, check for a burnt smell. This will indicate a failure of the electronics. Look for burnt wires and any

signs of lightning damage.3. Pull on the wires to see if any of them have come loose from the terminal block.4. Inspect the grounding wires and connections! Most controller failures are caused by an induced surge from

nearby lightning where the system is not effectively grounded. Ground connections must be properly made,tight, and free of corrosion. (See Section 5.2.)

Page 29: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

29

Check the low-water probe1. The probe system will work only if the pump’s ground wire is connected to the controller ground.2. The low-water probe is located near the top of the pump. Inspect it if you can.3. Did the probe or the probe wire break? To test, bypass it by connecting a small wire from the probe

terminal in the controller, to ground. If the pump works, there is a fault in the probe circuit.4. Does the pump run when the probe is OUT of the water? This can happen if it is coated with sediment,

minerals, bacteria or algae. These deposits, when wet, can provide a conductive path to the pump bodythat makes the probe “think” it is in the water. This is most likely to happen if the water is highly mineralizedor salty (highly conductive).

5. Raise the pump so the probe is above the water. If the pump doesn’t stop, disconnect the probe wire fromthe controller. Measure the resistance between the probe wire and ground. If it is less than 17KΩ (17,000ohms), there is conductivity between the probe and the pump and the pump will run. This can be caused bydeposits on the probe structure that hold moisture, especially if the water is highly mineralized (conductive).

6. If deposits on the probe are a problem, consider using a different type of probe or a different way to mountit, to isolate it more from the motor. Mount it on plastic pipe above the pump. You can also substitute a floatswitch if there is sufficient space in the water source. Connect one side of the switch to the probe terminalin the controller, and the other side to ground.

7. After years of operation, the probe may be “eaten away” by electrochemical action, especially in highlymineralized water. Replace the probe.

Check the float switch1. Inspect the float switch. Is it stuck in the UP position?2. The float switch will CLOSE contact to stop the pump if the tank is full. Was the wrong type of switch

installed (one that opens contact on rise)?3. To test for a fault, bypass it by disconnecting one float switch wire from the controller.

Force a quick startIf you restore a connection or bypass the probe or float switch, there is no need to wait for the normal timedelay. Switch the on/off switch (or the power source) off for a few seconds, then on again. The pumpshould start immediately if sufficient power is present.

9.3 Testing the System

Test the solar array circuit1. OPEN-CIRCUIT VOLTAGE You can do this easily by opening and switching off the array disconnect

switch. The reading should be 72-96V (with a 48V nominal array) or 55-72V (with 36V nominal solar array).This should vary only slightly with solar intensity. This is “idle” voltage when no current is being drawn (noload).

2. VOLTAGE UNDER LOAD (with pump running) This should be 60-73V (with a 48V nominal array) or 45-55V (with 36V nominal solar array). This should vary only slightly with solar intensity.

3. CURRENT UNDER LOAD Measuring current is the way to determine if the solar array’s output is equal toits full potential. This requires either a DC clamp-on amp meter or a conventional meter wired in series withthe array circuit (by breaking either + or – connection and running the circuit through the meter). Thecurrent is determined by both the array AND the load in the circuit (the pump system). If the pump is notdrawing full power, it will not draw full current.

4. SHORT CIRCUIT CURRENT This will give you an indication of the array output independent of thefunction of the pump system. This is extremely helpful if the pump is trying to start or does not seem to begetting full power.

WARNING DO NOT make a direct connection (short circuit) across the solar array wires while theyare connected to the controller. An amp meter connected across the solar array will cause a shortcircuit. There will be a high discharge from capacitors in the controller. This can damage the controller andyour meter and will void your warranty.

Measure short circuit amps only with the array DISCONNECTED from the controller. This will not damagethe solar array if it is done for a minute or less. You can do this easily by opening and switching off thearray disconnect switch. You should see a blue spark when short-circuiting the solar array exposed tosunshine. (Unlike other power generators, a short circuit will only cause current slightly higher than normal.)

If the solar array was connected to the controller in reverse

Page 30: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

30

Reverse polarity (+/–) at the controller’s POWER IN terminals will cause a fuse in the controller to blowimmediately. It’s purpose is to prevent serious damage to the controller. To replace the fuse, remove thefour screws from the back of the controller and slide out the internal assembly. The fuse will be foundbehind the POWER IN terminals. Test the fuse by removing it from its holder and using your multimeter totest continuity. A spare fuse is taped inside the box. Additional fuses are available from electronic suppliers.The description is “5 X 20mm, 10 amp, time-delay”. Do not substitute a different fuse. If the fuse blows forany reason other than reverse polarity, the controller must be repaired or replaced.

Test the controller power output (with power on)1. Make these tests with the pump connected and the power turned on. Observe caution!2. Use an AC voltmeter or a multimeter set to AC volts.3. Measure between each combination of two pump wires (L1–L2 / L1–L3 / L2–L3).4. Voltage should be 20-60VAC, depending on the power available and the load. Each reading must be equal.

Note: Any AC meter should be sufficiently accurate. It does not need to be a “True RMS” meter.

Test the motor circuit (with power off)This resistance test will confirm the condition of the entire motor circuit, including the motor, pump cable andsplice. Make this test if there is proper voltage at the controller input but the motor does not run.1. Disconnect power from the controller, or just turn it off.2. Disconnect at least two of the three pump power wires from the controller terminals.3. Use a multimeter set on resistance (RX1 or Ω).4. Measure between each combination of two pump wires (L1–L2 / L1–L3 / L2–L3).5. The resistance should be .1 to 1.5 ohm (Ω), depending on the length and size of the pump cable. EACH

READING MUST BE EQUAL.6. Measure resistance between the ground wire and the power wires. Your meter should show either no

reading, or more than 100 MΩ (that means 100 million Ω or 100 megohms). A lower reading indicates aninsulation fault in a power wire to the pump.

9.4 If the Pump Runs But Flow is Less Than Normal

1. Is the solar array receiving shadow-free light? Is it oriented properly toward the south, and tilted at theproper angle? See Section 4.

2. Be sure you have the right pump for the total lift that is required – out of the well + up the hill. In the case ofa pressurizing system, the pressure head is equivalent to additional lift (1 PSI = 2.31 feet).

3. Be sure all wire and pipe runs are sized adequately for the job. Refer to wire sizing in the pump sizingtable, and to the pipe sizing chart in this manual.

4. Inspect and test the solar array circuit and the controller output, as described above. Write down yourmeasurements.

Has the flow decreased over time?1. The pump end (pump mechanism attached to motor) may be worn from abrasive material (sand, silt, clay)

in the water. Is sediment accumulating in the water tank or pipes? If this has happened, remove the pumpfrom the water source and purchase a replacement pump end. It can be easily replaced with common handtools. (The assembly of pump end to motor is identical to that of conventional AC submersible pumps.)

2. Inspect the intake screen on the pump (only pumps with “C” in the model number have an intake screen.) Itmay be blocked by accumulated material. Clean it.

3. Remove the pipe from the pump outlet (check valve) and see if sand or silt is blocking the flow. If there is,See Section 6.6 Coping With Dirty Water Conditions.

The pump may be running in reversePumps with a “C” in the model number (centrifugal) will produce partial pressure if they are run in reverse.Pressure may be sufficient to produce some flow from the well, but far less than normal. Other models(helical rotor) will not pump in reverse. Motor reversal only happens if the pump is wired to the controllerimproperly. This is possible if the pump wires are connected to the controller in the wrong order. SeeSection 5.8 “Wiring Order for Correct Rotation”.

BEFORE CALLING FOR HELP

Page 31: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

31

please prepare the following information1. Controller model and serial number2. Pump model and serial number3. The status of indicator lights on the controller4. Any meter readings that you have taken5. Any other observations

10 Maintenance

10.1 Controller and Pump

Controller The controller is electronic with no moving or wearing parts. It requires no regular maintenance.Inspect it annually to see that it is securely mounted and that the wire entrances are sealed.

Motor Moving parts are water-lubricated and require no regular or preventive maintenance. The motor ispermanently sealed and has no brushes or other frequently-wearing parts.

Pump end The pump mechanism (pump end) may be worn after some years if there is abrasive solids in thewater. If the performance of the pump has dropped (but electrical measurements are normal) Inspect thepump end. If it is not blocked by sediment or corrosion, it is worn and must be replaced.. This can be easilydone in the field, after the pump is pulled from the well. Replacement of the pump end requires only a 13mmwrench and (for helical rotor models) a 3mm hex key (Allen wrench).

10.2 Solar Array

Solar array mounting bolts Bolts tend to loosen as the array structure flexes in high winds. Check tightness. Allbolts should all have lock washers to keep them tight.

Sun exposure Cut away any vegetation that will grow enough to block solar illumination. Shading even a smallcorner of the solar array may stop the pump, or greatly reduce its flow.

Solar array cleaning If there is dirt, mineral deposits, bird droppings or other debris stuck to the solar arraysurface, clean it with water, vinegar or glass cleaner.

Solar Array Tilt See Section 4.5.

Solar Tracker If the system uses a solar tracker, lubricate the bearings, check mounting bolts and mechanism. onOn a passive tracker, the shock absorber(s) may fail every few years. To test, swing the tracker by hand. Itshould return slowly due to damping action of the shock absorber. If it returns immediately (and swings in thewind) replace the shock absorber. Refer to tracker manufacturer's instructions.

10.3 Electrical Wiring

Power wiring Inspect carefully. Any wires that are hanging loose should be secured to prevent them fromswinging in the wind. Exposed wiring must be sunlight resistant and in good condition. In the case of atracking array, look carefully for any wire damage due to rubbing or pulling as the tracker swings. If wiring wasnot performed to professional standards, improve it to prevent faults in the future.

Grounding Inspect the grounding system carefully. All connections must be tight and free of corrosion. Poorgrounding can lead to damage from lightning-induced surges. See Section 5.2.

Page 32: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

32

11 ETAPUMP WARRANTY

ETAPUMP® pumps, motors and controllers are warranted to be free from defectsin material and workmanship for two (2) years from date of purchase.

When purchased as part of an ETAPUMP INTEGRATED SYSTEM™supplied directly or indirectly by Dankoff Solar Products, Inc.,the pump and controller warranty is extended to four (4) years

Failure to provide correct installation, operation, or care for the product, in accordance with the instruction manual,will void the warranty. Product liability, except where mandated by law, is limited to repair or replacement, at thediscretion of the manufacturer or importer.

Neither manufacturer nor importer is responsible for the labor or other charges necessitated by the removal,transportation, or reinstallation of any defective product.

Warranty does not cover damage due to failure to install the device properly, mishandling or abuse, failure toprotect circuitry from weather exposure, failure to protect circuitry from overheating due to sun exposure, failure toprotect from salt spray or other corrosive factors, failure to seal out insects, spiders or rodents, lightning, flood orother acts of nature.

Warranty does not cover damage due to sand or abrasive particles in the water, or incompatibility of pumpmaterials with corrosive or reactive substances, or from running the pump with an insufficient supply of water.

No specific claim of merchantability shall be assumed or implied beyond what is printed on the manufacturer's orimporter's printed literature. No liability shall exist from circumstances arising from the inability to use the product, orits inappropriateness for any specific purpose. It is the user's responsibility to determine the suitability of the productfor any particular use.

In all cases, it shall be the responsibility of the customer to ensure a safe installation in compliance with local, stateand national electrical codes.

12 ETAPUMP STANDARDS & ENVIRONMENTALSPECIFICATIONS

ETAPUMP controllers are built to DIN-VDE regulations and carry the CE stamp indicating that the European Unionelectromagnetic interference standards (Dt. EMV) have been fulfilled. Printed circuit boards are conformal-coatedagainst moisture. The enclosure is thick anodized aluminum, gasket-sealed and raintight for any outdoorenvironment (enclosure class IP55). The controller is suited to tropical conditions according to IEC 68-2-30. Thecontroller is not submersible.

Temperature RangesPump and motor Water temperature 32° to 86°F (0 to 30°C)Controller Ambient temperature -13° to 140°F (-25° to 60°C)

Other system components The PV modules (solar panels) and the disconnect switch in the ETAPUMPIntegrated System™ (complete PV-direct systems supplied by Dankoff Solar Products) are UL-listed and carryother international standard ratings.

Page 33: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

33

13 REFERENCE SECTION

13.1 Principles of Operation

Solar array Photovoltaic (PV) cells produce electricity directly from sunlight (not from heat). Light causeselectrons to jump from the top layer of the cell, into “holes” in the layer underneath. When a circuit is made betweentop and bottom layers, electric current. Each cell produces about 1/2 volt. As sunlight varies, the voltage staysnearly constant but the current (amps) varies.

A multitude of PV cells are connected in series for the desired voltage, and sealed under glass to make a “PVmodule”. ETAPUMP systems use 3 to 12 modules. The assembly of modules is called a “PV array”. There are nomoving or wearing parts in PV modules. The glass used in high quality PV modules is tempered, and is extremelystrong.

Brushless motor system ETAPUMP uses a brushless DC motor system consisting of a special 3-phase ACpermanent magnet motor, and a controller that changes the solar DC power to 3-phase AC. The motor’s speed isdetermined by the frequency of the AC power. The controller varies the frequency to bring the motor up to speedslowly, without a power surge. It then adjusts the motor speed according to the power available from the sun.

Less expensive solar pumps have a traditional DC motor that uses “brushes” (small blocks of carbon-graphite) toconduct current to the spinning part of the motor. Not only do the brushes wear out in a few years, but it isnecessary to have air in the motor and a perfect seal to keep water out. The ETAPUMP brushless motor is filledwith water by design! It is lubricated by water and is entirely maintenance-free. It is similar mechanically toconventional AC submersible motors that have been proven for decades. It creates a spinning magnetic field thatforces the shaft to spin.

Controller (EP-600 for solar-direct operation) The controller starts the pump slowly and adjusts its speedaccording to the pumping load and the power available from the solar array. Power output from the array isoptimally matched to the load by maximum power point tracker (MPPT) and linear current booster (LCB) systems,to produce maximum power transfer throughout all conditions. The LCB function is analogous to an automatictransmission in an automobile. It starts the pump in “low gear” (it lowers the array voltage and boosts the current).Under low sun conditions, it stays in “low gear” to resist stalling. As sunlight increases, it advances continuouslytoward “high gear” (higher voltage). The MPPT system tracks changes in the array voltage. Array voltage variesprimarily with temperature (higher at low temperatures). When the pump stalls in low sunlight, the controllerswitches the pump off to prevent heating of the motor.

The controller converts the DC power from the solar array to 3-phase AC power to run the motor. Motor speed(RPM) is proportional to the AC frequency. The frequency starts low (about 20 Hz), and increases gradually to amaximum of 3400 RPM (70 Hz). The pump is not allowed to operate below a minimum speed. The factory setting is1000 rpm. This is a good setting under most conditions. It can be changed by an internal adjustment. Atemperature sensor is installed in the controller to cut the power if it gets too hot for any reason.

The float switch circuit operates at 12VDC, carrying maximum current of 4.7mA. When the circuit is made, it stopsthe pump (opposite logic). This is so the pump will continue to operate if the circuit is accidentally broken.

The low-water probe circuit applies 5VDC to the probe. The water conducts a small amount of current from theprobe to the body of the pump. If the probe is out of the water (the resistance of the circuit is more than 17 KΩ) thecontroller stops the pump. When the water level recovers, there is a 20 minute delay before restart.

Pump end – centrifugal models Pumps with a MODEL NUMBER CONTAINING “C” use a multi-stagecentrifugal pump end, similar to that of conventional well pumps – this is for high volume at 75 feet (23m) or less.

Pump end – helical rotor models Pumps with a MODEL NUMBER THAT DOES NOT CONTAIN “C” have ahelical rotor pump end (also called “progressive cavity” pump). The rotor fits closely into a rubber stator that has ahelical groove. The space between the rotor and stator contains sealed cavities that trap water. As the rotor turns,the cavities progress toward the outlet.

Page 34: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

34

ETAPUMP – HELICAL ROTOR MODELS ONLY

Positive displacement action The helical rotor pump differs from centrifugalpumps in that it maintains high efficiency and lift capacity even at low rotationalspeeds and low flow rates. This allows ETAPUMP to work with a small,inexpensive solar array, and to function in low sunlight conditions. (Centrifugalpump ends are better for low-lift, high-flow applications. They are used on pumpsthat contain “C” in the model number.)

The ETAPUMP helical rotor has only one moving part. It produces a smoothflow and requires no valves to function. It is far more reliable than diaphragm andpiston-type solar pumps.

Self-cleaning action The rotor sweeps the full surface of the rubber stator withevery turn. It is impossible for deposits to accumulate. Solid particles tend to rollaway from the contact area, making the pump extremely resistant to abrasion.Particles that are trapped against the rubber are tolerated by the flexibility ofrubber.

Some history Helical rotor pumps have been used in the oil industry for over60 years. They are used to pump abrasive slurries, even concrete! They havebeen used for solar pumping for over 10 years, but were very expensive untilETAPUMP was introduced.

PHOTO LEFT — Motor with helical rotor attached, stator housing removed.

PHOTO BELOW — Close-up of the same rotor. This is a test specimen thatpumped extremely sandy water for 500 hours in the test lab. The surface isslightly abraded, but the pump still performs to full specifications.

Sealed cavities trap water andprogress toward the outlet

helical rotor rubber stator

Page 35: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

35

13.2 Water Pipe Sizing Chart

Don’t cheat yourself with undersized pipe! Use this chart to determine the additional head imposed on yourpump due to pipe friction, based on flow rate, pipe size and pipe length. Consider the TOTAL pipe length from thepump to the pipe outlet or top of storage tank.

Pipe fittings impose additional friction loss. A 90° pipe elbow adds friction approximately equal to 6 feet (2m) ofpipe.

Water Pipe Sizing ChartFriction Loss in Plastic Pipe with Standard Inside Diameter (SIDR)

THIS CHART APPLIES ONLY TO: PVC pipe, Schedule 40 (160 PSI) and topolyethylene (PE) pipe with SIDR designation (most common 100 PSI black flex pipe)

HEAD LOSS from friction in feet per 100 feet of pipeor vertical meters per 100 meters of pipe

NOMINAL PIPE DIAMETER (Inches) FLOW RATE 1 / 2 * 3 / 4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6

GPM LPM 0.662 0.82 1.05 1.38 1.61 2.07 2.47 3.07 4.03 5.05 6.06

1 3 .8 1.13 0.14 0.05 0.02 actual inside diameter (inches)

2 7 .6 4.16 0.35 0.14 0.05 0.023 11.4 8.55 2.2 0.32 0.09 0.054 1 5 14.8 3.7 0.53 0.16 0.09 0.02 SHADED VALUES are at5 1 9 22.2 5.8 0.81 0.25 0.12 0.05 velocities over 5 feet per6 2 3 31.0 7.9 1.0 0.35 0.18 0.07 0.02 second and should be7 2 7 10.6 1.5 0.46 0.23 0.08 0.03 selected with caution8 3 0 13.4 1.9 0.58 0.30 0.09 0.059 3 4 16.9 2.4 0.72 0.37 0.12 0.06

1 0 3 8 20.3 2.9 0.88 0.46 0.16 0.07 0.021 1 4 2 24.3 3.5 1.04 0.53 0.18 0.08 0.031 2 4 5 28.6 4.1 1.2 0.65 0.21 0.09 0.041 4 5 3 5.5 1.6 0.85 0.28 0.12 0.051 6 6 1 7.0 2.1 1.1 0.37 0.14 0.061 8 6 8 8.7 2.6 1.3 0.46 0.18 0.072 0 7 6 10.6 3.2 1.6 0.55 0.21 0.08 0.022 2 8 3 13.4 3.8 2.0 0.67 0.25 0.09 0.032 4 9 1 14.9 4.4 2.3 0.79 0.30 0.12 0.042 6 9 9 5.2 2.7 0.90 0.35 0.14 0.052 8 1 0 6 5.9 3.1 1.0 0.42 0.16 0.053 0 1 1 4 6.7 3.5 1.2 0.46 0.18 0.063 5 1 3 3 8.9 4.6 1.6 0.62 0.23 0.074 0 1 5 2 1.4 5.9 2.0 0.79 0.30 0.09 0.024 5 1 7 1 14.2 7.4 2.5 0.97 0.37 0.12 0.045 0 1 9 0 17.3 9.0 3.0 1.2 0.46 0.14 0.055 5 2 0 8 10.7 3.6 1.4 0.55 0.16 0.066 0 2 2 7 12.5 4.2 1.7 0.65 0.18 0.07 0.026 5 2 4 6 14.6 4.9 1.9 0.74 0.22 0.08 0.037 0 2 6 5 * 1/2" data 16.7 5.6 2.2 0.85 0.25 0.09 0.047 5 2 8 4 applies to 19.0 6.4 2.5 0.97 0.28 0.10 0.058 0 3 0 3 polyethylene 7.2 2.8 1.1 0.32 0.12 0.068 5 3 2 2 pipe only. 8.1 3.2 1.2 0.37 0.14 0.079 0 3 4 1 PVC has smaller 9.0 3.5 1.4 0.39 0.15 0.089 5 3 6 0 ID of .612" 9.9 3.9 1.5 0.44 0.16 0.09

1 0 0 3 7 9 10.9 4.3 1.7 0.49 0.18 0.121 5 0 5 6 9 23.1 9.1 3.5 1.0 0.37 0.162 0 0 7 5 8 15.5 6.0 1.8 0.62 0.28

Courtesy of Dankoff Solar Products, Inc.

Page 36: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

36

13.3 Wellhead Assemblies for Drilled Wells

To support the drop pipeand seal the wellhead,

choose one of these methods

These methods are NOT specific to solar pumps. Thecomponents are available from conventional water wellsuppliers.

Well Seal System

This is a plate that fits on top of the well casing. Itprovides a seal against contamination of the well, and itsupports the weight of the in-well assembly. In a freezingclimate, the wellhead must be located in a heatedbuilding or in a covered well pit.

Use metal pipes above ground, for strength. A tee and aplug is used instead of an elbow, because the plugallows direct observation of water level and flow. It alsoprovides a place to attach a lifting device.

Pitless Adapter System

The pitless adapter is a fitting that allows your buried pipe topass through the well casing underground, without the needto build a covered pit. It provides protection against freezing,flooding, animals and human activities that can damageexposed piping.

After the pitless adapter is installed on the casing, the pumpcan be installed and removed from above, with no need todig. The inside half slides apart vertically by means of adovetail joint and an O-ring. A piece of threaded pipe is usedas a temporary puller tool. Thread it into the socket on theremovable half of the adapter to serve as a handle.

If your well casing is 4" (inside diameter) be certain that yourpitless adapter is the type that will not reduce the clearanceinside the casing (it must clamp around the outside of thecasing). If you have a well casing of 6” or larger, you may beable to install two pumps in the well, by using two pitlessadapters.

Check ValveThis is a one-way valve that we recommend close to thewellhead. It prevents your stored water supply from escapingdown the well in case of a leak in your drop pipe. For apitless adapter installation, install it underground outside ofthe casing, or elsewhere if it’s not far away. If you use aweep hole for freeze protection, omit this check valve toallow drainage.

well seal

well casing

plugelectrical cable

check valve

eye-bolt

ground level

metal pipe

section

safety rope

well cap

well casing

electrical conduit

ground level

junction box

drop pipe

eye-bolt for safety rope

check valve

electrical cable

temporary puller pipe

pitless adapter

Page 37: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

37

13.4 Water Storage for Solar Water Pumps

Storage Tank Capacity

Generally, your storage capacity should equal 3 to 10 days of average water consumption, or more. This dependson your climate and your usage patterns. For domestic use in a cloudy climate, 10 days is minimal. In a sunnyclimate, this allows for a generous safety margin. For deep irrigation of trees (where the soil holds moisture for aweek) 3 days’ storage may be adequate. For irrigating a garden, 5 days may be adequate. You cannot store toomuch water!

Storage Tank Plumbing

Place your normal point ofdischarge higher than the bottomof your water tank, in order tohold a reserve so that the tankdoes not run completely dry. Youcan lose your water supply underany of these conditions:1. a period of low sunshine

and/or excessive waterdemand

2. an electrical or mechanicalfailure in the system

3. a leak in the tank or piping4. an accidental discharge of

stored water

Place a second outlet valve at thebottom level of your storage tank,to use the reserve supply in caseof emergency.

Pipe sizing The pipe from thepump to the tank may need to belarger than the pump outlet,depending on the flow and thelength of pipe. A single pipe maybe used as both fill anddischarge. In that case, size thepipe for the maximum dischargethat you want to accomplish.Also, consider oversizing the pipeif there is a chance that you maywant to install a second pump, orlarger pump in the future. Sizingthe pipe larger than necessary willNOT influence the performance ofthe system. See “Water PipeSizing Chart”.

If you plan to use gravity-flow to supply water from the storage tank, be sure the discharge pipe is large enough toallow sufficient flow to meet the maximum water demand without excessive friction loss.

Pressure of delivery Every 2.3 feet vertical feet of drop produces 1 PSI of pressure, minus any friction loss (10mproduces 1 bar). The volume of water stored in the tank does not effect the pressure delivered.

Reserve Supply

Inlet pipe (optional)Feed well water in at this level IF you want the

pipe from the well to drain after the pump stops. (See "Freeze Protection")

Your choice of inlet here or at top of tank will NOT significantly effect pump performance.

Inlet/Outlet PipeA single pipe can handle water

going both into and out of the tank.

Float Switch

cable weight

Overflow outletIf float switch is used: this drains excess water

safely away in case the float control system fails.If float switch is not used, this can send water to

additional storage or irrigation.

--on

--off

Refresher valve (optional) A slow leakage of water at this level will cause the pump to refresh

the water periodically during times of low demand.

Air Vent Required if top of tank is sealed, particularly if the tank is buried

cable to pump controller

Check Valve(spring-loaded

type)

Reserve Shutoff Valve

Drain / Cleanout Valve

(both normally closed)

Main Shutoff Valve (normally open)

Note the relatively large size of the main discharge pipe. This facilitates gravity flow with minimal pressure loss.

Water Meter (optional)

To Water Distribution

System

Water Well

top view

Monitoring Valve(optional)

Wireless Level Control for full-tank shutoff (optional)

This eliminates float switch and cable. It uses a pressure sensor

on the pipe. See Automatic Control for Full-Tank Shutoff.

Page 38: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

38

13.5 Monitoring a Solar Pump System

Monitoring the pump Will you be able to observe the output of your pump at the point of discharge? If not, youmay not know if it malfunctions. Consider installing a water meter, or additional valves so that the flow can bedirectly observed. (See illustration in Section 13.4)

Monitoring the water level in your storage tank Will you be able to observe the level of water in your tank? Ifyou cannot easily see into your storage tank, here are some methods of tank monitoring.1. dipstick in the air vent2. float with a visible rod that protrudes through the top of the tank3. clear sight-tube alongside the tank4. precision pressure gauge (note: 1 PSI = 2.3 feet)5. “Wireless Level Controller” (see Section 5.10).

13.6 Freeze Protection for Solar Water Pumps

Burying the pipe In a cold climate, water can freeze in a pipe and block the water flow. This will cause anelectrical overload that will prevent the pump from reaching full speed. The best way to prevent freezing is to installa pitless adapter at the wellhead and bury all piping below frost line (see section 13.3 Wellhead Assemblies forDrilled Wells).

Will the pump drain back when it stops? NO! The pump has a check valve that stops water from draining backdown when it stops. Helical rotor models (model number not containing “C”) will not drain back even if the checkvalve is removed.

WARNING Do not install the pump with its check valve removed.

Weep hole If you have above-ground piping that must be drained for freeze protection, make a tiny "weep hole" inthe drop pipe, below frost line. This will cause a constant but small leakage of water back into the well. When thepump stops, the pipe will drain slowly. The pipe must be sloped without low spots, so it drains completely. In plasticpipe, a weep hole can be made with a hot needle or an extremely small drill bit, or a needle valve can be installedand adjusted.

Weep hole—high tech version The most reliable dripping device is one that is engineered for a similar purpose.Drip irrigation systems use precise emitters to drip water reliably. A drip emitter resists accumulation of debris andmineral deposits far better than a simple hole or a needle valve. Drip emitters are rated in very low gallons (liters)per hour. Use a relatively fast one for best reliability. Emitters are very inexpensive. They are available fromirrigation suppliers, nurseries, and many hardware stores. Drill a hole in the pipe to fit the emitter, and push theemitter into the hole.

Pressure relief If there is any possibility of a pipe freezing, install a pressure relief valve to prevent excesspressure in the pump line. Install it below frost line. Adjust the valve to open if it exceeds the pressure exceedsnormal.

Page 39: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

39

13.7 Obtaining and Using a Multimeter for Trouble Shooting

Most on-site trouble shooting requires a test instrument called a multimeter, which is available at electrical supply,electronic supply, automotive and hardware stores. Use it to measure DC voltage, DC current (amps) andresistance (ohms, symbolized by Ω). A digital meter is best. Here are the criteria for selecting a good meter.

Resistance ranges The meter must read in the 0-10Ω range to one decimal place. This includes all but thecheapest digital meters, and any analog meter that has at least three resistance ranges.

Ammeter ranges These are the options, listed in order of benefit and cost:1. Milliamp range but no Amp range (under $35 in USA). This will be useful for voltage and resistance

measurement, but not for current. It is sufficient for the most elementary trouble shooting.2. Amp range to 10 or 20A. This will measure PV array current and pump running current. This will help you to

solve performance problems.3. DC/AC clamp-on ammeter. This allows measurement of current without disconnecting wires. We strongly

recommend this type of meter if you maintain numerous solar pumps or other electrical equipment. Fluke Model33 or 36 is the professional favorite. Cheaper ones have been unreliable. AC-only clamp-on meters will NOTmeasure DC current.

True RMS accuracy This is NOT NECESSARY for testing ETAPUMP.

Use two meters for easier testing. It helps to measure voltage and current simultaneously. An inexpensivemeter is adequate for voltage, because precision is not necessary. Clip-wires or clip-probes are also helpful, if youdon’t have three hands.

Resistance readings are always taken with NO POWER applied to the circuit. Always use the LOWEST scalethat produces a reading (for example RX1, not RX10).

Zero adjustment Some meters require zero-adjustment to insure accuracy. This applies to analog metersmeasuring resistance, and to clamp-on ammeters measuring current. Be sure to set the zero if necessary!

WARNING Read the instructions that come with your meter, and follow the safety warnings.

WARNING Attempting to read current (amps) between the two poles of a power circuit causes a potentiallydangerous short circuit. Connect the probes IN SERIES with the circuit (see your meter’s instructionmanual).

WARNING To read voltage, the red probe must NOT be in the Amps socket. This will cause a short circuit.

13.8 A Meter for Measuring Solar Energy Intensity

To evaluate the performance of a solar-direct solar pump, it is very helpful to measure sun intensity at the sametime that you observe the solar pump. For example, if the solar pump is producing around 60% of the specifiedmaximum flow, and you measure the sun intensity (in the same plane as the array) as 60% of full sun, you knowthat the system is working well.

The Daystar Meter is a hand-held instrument that measures sun intensity using a PV cell that is similar to thoseused to power ETAPUMP. It displays instantaneous intensity in Watts per square meter (W/m2). The industry-standard for full sun intensity is 1000 W/m2, so a reading of 600 indicates 60% intensity.

The meter costs less than US$150. Order directly from the manufacturer:Daystar, Inc. 3240 Majestic Ridge, Las Cruces, NM 88011 USA.(505) 522-4943 [email protected] www.raydec.com/daystar

Page 40: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

40

13.9 Glossary of Solar Electricity and Water Pumping

Courtesy of Dankoff Solar Products, Inc.2810 Industrial Rd.

Santa Fe, NM USA 87505(505) 473-3800 www.dankoffsolar.com

Basic Electricity

AC - Alternating Current, the standard form of electrical current supplied by the utility grid and by most fuel-powered generators. The polarity (and therefore the direction of current) alternates. In U.S.A., standard voltagesfor small water pumps are 115V and 230V. Standards vary in different countries. See inverter.DC - Direct Current, the type of power produced by photovoltaic panels and by storage batteries. The currentflows in one direction and polarity is fixed, defined as positive (+) and negative (-). Nominal system voltage may beanywhere from 12 to 180V. See voltage, nominal.Current - The rate at which electricity flows through a circuit, to transfer energy. Measured in Amperes,commonly called Amps. Analogy: flow rate in a water pipe.Efficiency - The percentage of power that gets converted to useful work. Example: An electric pump that is 60%efficient converts 60% of the input energy into work - pumping water. The remaining 40% becomes waste heat.Energy - The product of power and time, measured in Watt-Hours. 1000 Watt-Hours = 1 Kilowatt-Hour(abbreviation: KWH). Variation: the product of current and time is Ampere-Hours, also called Amp-Hours(abbreviation: AH). 1000 watt consumed for 1 hour = 1 KWH. See power.Converter - An electronic device for DC power that steps up voltage and steps down current proportionally (orvice-versa). Electrical analogy applied to AC: See transformer. Mechanical analogy: gears or belt drive.Inverter - An electronic device that converts low voltage DC to high voltage AC power. In solar-electric systems,an inverter may take the 12, 24, or 48 volts DC and convert it to 115 or 230 volts AC, conventional householdpower.Power - The rate at which work is done. It is the product of Voltage times Current, measured in Watts. 1000Watts = 1 Kilowatt. An electric motor requires approximately 1 Kilowatt per Horsepower (after typical efficiencylosses). 1 Kilowatt for 1 Hour = 1 Kilowatt-Hour (KWH).Three-Phase AC - Three phase power is AC that is carried by three wires. Power waves are applied in asequence. Three-phase is used for large industrial motors, variable-speed motors, and brushless solar water pumpmotors. Analogy: 3-cylinder engine.Transformer - An electrical device that steps up voltage and steps down current proportionally (or vice-versa).Transformers work with AC only. For DC, see converter. Mechanical analogy: gears or belt drive.Utility Grid - Commercial electric power distribution system. Synonym: mains.Voltage - The measurement of electrical potential. Analogy: Pressure in a water pipe.Voltage Drop - Loss of voltage (electrical pressure) caused by the resistance in wire and electrical devices.Proper wire sizing will minimize voltage drop, particularly over long distances. Voltage drop is determined by 4factors: wire size, current (amps), voltage, and length of wire. It is determined by consulting a wire sizing chart orformula available in various reference tests. It is expressed as a percentage. Water analogy: Friction Loss in pipe.Voltage, Nominal - A way of naming a range of voltage to a standard. Example: A "12 Volt Nominal" systemmay operate in the range of 11 to 15 Volts. We call it "12 Volts" for simplicity.

Solar Electricity

Photovoltaic - The phenomenon of converting light to electric power. Photo = light, Volt = electricity.Abbreviation: PV.PV - The common abbreviation for photovoltaic.PV Array - A group of PV (photovoltaic) modules (also called panels) arranged to produce the voltage and powerdesired.PV Array-Direct - The use of electric power directly from a photovoltaic array, without storage batteries to store orstabilize it. Most solar water pumps work this way, utilizing a tank to store water.PV Cell - The individual photovoltaic device. Most PV modules are made with around 36 or 72 silicon cells, eachproducing about 1/2 volt.

Page 41: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

41

PV Module - An assembly of PV cells framed into a weatherproof unit. Commonly called a "PV panel". See PVarray.Solar Tracker - A mounting rack for a PV array that automatically tilts to follow the daily path of the sun throughthe sky. A "tracking array" will produce more energy through the course of the day, than a "fixed array" (non-tracking) particularly during the long days of summer.Voltage, Open Circuit - The voltage of a PV module or array with no load (when it is disconnected). A "12 VoltNominal" PV module will produce about 20 Volts open circuit. Abbreviation: Voc.Voltage, Peak Power Point - The voltage at which a photovoltaic module or array transfers the greatest amountof power (watts). A "12 Volt Nominal" PV module will typically have a peak power voltage of around 15-17 volts.The solar array for a PV array-direct solar pump should reach this voltage in full sun conditions, or a multiple of thisvoltage. Abbreviation: Vpp.

Pumps & Related Components

Booster Pump - A surface pump used to increase pressure in a water line, or to pull from a storage tank andpressurize a water system. See surface pump.Centrifugal Pump - A pumping mechanism that spins water in order to push it out by means of centrifugal force.See also multi-stage.Check Valve - A valve that allows water to flow one way but not the other.Diaphragm Pump - A type of pump in which water is drawn in and forced out of one or more chambers, by aflexible diaphragm. Check valves let water into and out of each chamber.Float Switch - An electrical switch that responds to changes in water level. It may be used to prevent overflow ofa tank by turning a pump off, or to prevent a pump from running dry when the source level is low.Float Valve - A valve that responds to changes in water level. It is used to prevent overflow of a tank by blockingthe flow of water.Foot Valve - A check valve placed in the water source below a surface pump. It prevents water from flowing backdown the pipe and "losing prime". See check valve and priming.Helical Rotor Pump - A pump with a helix-shaped rotor that fits closely into a rubber stator that has a helicalgroove. It forms sealed cavities that trap water. As the rotor turns, the cavities move toward the outlet. See positivedisplacement pump. Synonyms: progressive cavity pump, screw pump.Impeller - The device that spins inside of a centrifugal pump, in order to develop centrifugal force.Jet Pump - A surface-mounted centrifugal pump that uses an "ejector" (venturi) device to augment its suctioncapacity. In a "deep well jet pump", the ejector is down in the well, to assist the pump in overcoming the limitationsof suction. (Some water is diverted back down the well, causing an increase in energy use.)Multi-Stage Centrifugal - A centrifugal pump with more than one impeller and chamber, stacked in a sequence toproduce higher pressure. Conventional AC deep well submersible pumps and some solar submersibles work thisway.Positive Displacement Pump - Any mechanism that seals water in a chamber, then forces it out by reducing thevolume of the chamber. Examples: piston, diaphragm, helical rotor, vane. Used for low volume and high lift.Contrast with centrifugal. Synonyms: volumetric pump, force pump.Priming - The process of hand-filling the suction pipe and intake of a surface pump. Priming is generallynecessary when a pump must be located above the water source. A self-priming pump is able to draw some airsuction in order to prime itself, at least in theory. See foot valve.Pulsation Damper - A device that absorbs and releases pulsations in flow produced by a piston or diaphragmpump. Consists of a chamber with air trapped within it or a length of flexible tube.Pump Jack - A deep well piston pump. The piston and cylinder is submerged in the well water and actuated by arod inside the drop pipe, powered by a motor at the surface. This is an old-fashioned system that is still used forextremely deep wells, including solar pumps as deep as 1000 feet.Self-Priming Pump - See priming.Submersible Pump - A motor/pump combination designed to be placed entirely below the water surface.Surface Pump - A pump that is not submersible. It must be placed no more than about 20 ft. above the surfaceof the water in the well. See priming. (Exception: see jet pump)

Page 42: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

42

Solar Pump Components

DC Motor, Brush-Type - The traditional DC motor, in which small carbon blocks called "brushes" conduct currentinto the spinning portion of the motor. They are used in most solar surface pumps and in some low-power solarsubmersibles. The motor chamber must be filled with air and perfectly sealed from moisture. Brushes naturallywear down after years of use, and must be replaced periodically.DC Motor, Brushless - High-technology motor used in more advanced solar submersibles. An electronic systemis used to precisely alternate the current, causing the motor to spin. See three-phase AC. A submersible brushlessmotor is filled with water and requires no maintenance.DC Motor, Permanent Magnet - All DC solar pumps use this type of motor in some form. Being a variablespeed motor by nature, reduced voltage (in low sun) produces proportionally reduced speed, and causes no harmto the motor. Contrast: induction motorInduction Motor (AC) - The type of electric motor used in conventional single-phase AC water pumps. It requiresa high surge of current to start, and a stable voltage supply, making it relatively expensive to run from by solarpower. See Inverter.Linear Current Booster (LCB) - An electronic device which varies the voltage and current of a PV array to matchthe needs of an array-direct pump, especially a positive displacement pump. It allows the pump to start and to rununder low sun conditions without stalling. Electrical analogy: variable transformer. Mechanical analogy: automatictransmission. Also called pump controller. See pump controller .Maximum Power Point Tracking (MPPT) - An added refinement in some linear current boosters, in which theinput voltage tracks the variations of the output voltage of the PV array to draw the most possible solar power undervarying conditions of temperature, solar intensity and load.Pump Controller - An electronic device that controls or processes the power to a pump. It may perform any ofthe following functions: stopping and starting the pump; protection from overload; DC-to-AC conversion; voltageconversion; power matching (see linear current booster). It may also have provisions for low-water shutoff and full-tank shutoff devices, and status indicators.

Water Well Components

Borehole - Synonym for drilled well, especially outside of North America.Casing - Plastic or steel tube that is permanently inserted in the well after drilling. Its size is specified accordingto its inside diameter.Cable Splice - A joint in electrical cable. A submersible splice is protected by a water-tight seal.Drop Pipe - The pipe that carries water from a pump in a well, up to the surface. It also supports the pump.Perforations - Slits cut into the well casing to allow groundwater to enter. May be located at more than one level,to coincide with water-bearing strata in the earth.Pitless Adapter - A special pipe fitting that fits on a well casing, below ground. It lets the pipe pass horizontallythrough the casing so that no pipe is exposed above ground where it could freeze. The pump may be installed andremoved without further need to dig around the casing. This is done by using a 1” threaded pipe as a handle.Safety Rope - Rope used to secure the pump in case of pipe breakage.Submersible Cable - Electrical cable designed for in-well submersion. Conductor sizing is specified in squaremillimeters, or (in North America) by American Wire Gauge (AWG) in which a higher number indicates smaller wire.It is connected to a pump by a cable splice.Well Seal - Top plate of a well casing that provides a sanitary seal and support for the drop pipe and pump.Alternative: See pitless adapter

Water Well Characteristics

Driller's Log - The document on which well characteristics are recorded by the well driller. In most states, drillersare required to register all water wells and to send a copy of the log to a state office. This supplies hydrologicaldata and well performance test results to the well owner and the public. Synonym: well record.Drawdown - Lowering of level of water in a well due to pumping.Drawdown level - Depth to the water surface in a well while it is being pumped.Recovery Rate - Rate at which groundwater refills the casing after the level is drawn down. This is the term usedto specify the production rate of the well.Static Water Level - Depth to the water surface in a well under static conditions (not being pumped). May besubject to seasonal changes or lowering due to depletion.Wellhead - Top of the well.

Page 43: eMan-KSB ETAPUMP® Solar Water Pump Instruction Manual

43

Pump System Engineering

Friction Loss - The loss of pressure due to flow of water in pipe. This is determined by 4 factors: pipe size(inside diameter), pipe material, flow rate, and length of pipe. It is determined by consulting a friction loss chartavailable in an engineering reference book or from a pipe supplier. It is expressed in PSI or Feet (equivalentadditional feet of pumping). Pipe fittings, especially 90° elbows, impose additional friction.Head - See synonym: vertical lift.Suction Lift - Applied to surface pumps: Vertical distance from the surface of the water in the source, to a pumplocated above the surface. This distance is limited by physics to around 20 feet at sea level (subtract 1 ft. per 1000ft. altitude) and should be minimized for best results.Submergence - Applied to submersible pumps: Distance below the static water level, at which a pump is set.Total Dynamic Head - vertical lift + friction loss in piping (see vertical lift and friction loss).Vertical Lift - The vertical distance that water is pumped. This determines the pressure that the pump pushesagainst. Total vertical lift = vertical lift from surface of water source up to the discharge in the tank + (in a pressuresystem) discharge pressure. Synonym: static head. Note: Horizontal distance does NOT add to the vertical lift,except in terms of pipe friction loss. NOR does the volume (weight) of water contained in pipe or tank.Submergence of the pump does NOT add to the vertical lift. See total dynamic head.

Water Distribution

Cut-In Pressure and Cut-Out Pressure - See pressure switch.Gravity Flow - The use of gravity to produce pressure and water flow. A storage tank is elevated above the pointof use, so that water will flow with no further pumping required. A booster pump may be used to increase pressure.2.31 vertical feet = 1 PSI. 10 vertical meters = 1 bar. See pressure.Head - Seevertical lift and total dynamic head. In water distribution, synonym: vertical drop. See pressure.Open Discharge - The filling of a water vessel that is not sealed to hold pressure. Examples: storage (holding)tank, pond, flood irrigation. Contrast: pressure tank.Pressure - The amount of force applied by water that is either forced by a pump, or by the gravity. Measured inpounds per square inch (PSI) or bar (atmospheres). PSI = vertical lift (or drop) in Feet / 2.31. 1 Bar = 10vertical meters.Pressure Switch - An electrical switch actuated by the pressure in a pressure tank. When the pressure drops toa low set-point (cut-in) it turns a pump on. At a high point (cut-out) it turns the pump off.Pressure Tank - A fully enclosed tank with an air space inside. As water is forced in, the air compresses. Thestored water may be released after the pump has stopped. Most pressure tanks contain a rubber bladder tocapture the air. If so, synonym: captive air tank.Pressure Tank Precharge - The pressure of compressed air stored in a captive air pressure tank. A readingshould be taken with an air pressure gauge (tire gauge) with water pressure at zero. The air pressure is thenadjusted to about 3 PSI lower than the cut-in pressure (see Pressure Switch). If precharge is not set properly, thetank will not work to full capacity, and the pump will cycle on and off more frequently.

Permission to reproduce and distribute Glossary of Solar Water Pumping is hereby granted to all parties.Prior notification and citation of author and copyright is requiredWritten by Windy DankoffCopyright © 1997-2002 by Dankoff Solar Products, Inc. All rights reserved

13.10 Handy Facts & Formulae

Vertical Lift is measured from the surface of the water source to the pump outlet orthe water level in the storage tank (whichever is higher) + pipe friction loss.The load on the pump is not affected by the volume of water in the pipe or in the tank!

A 48V pump requires 1/4 the wire size of a 24V pump for the same power (watts).

Amps = Watts PSI = Vert. Feet % Efficiency = Vert. Lift, Feet X GPM X 18.8 Volts 2.31 of any pump Watts