email: [email protected] / work@froscoweb

40
FROSCO OIL INTERCEPTOR SYSTEM We Reserve All Intellectual Property Rights In Our Products. Tested By : SIRIM Website : www.froscoweb.com MR. ONG H/P : 012-549 7710 (NORTHERN) MR. ALEX H/P : 012-713 0515 (SOUTHERN) Email: [email protected] / [email protected] MR. BRYANT TOH H/P : 017-8779458 (CENTRAL REGION) MR. PETER H/P : 012-233 3861 (EAST MALAYSIA & INTERNATIONAL) MR. ERIC ONG H/P : 016-919 9920 (CENTRAL REGION)

Upload: others

Post on 24-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

FROSCO OIL INTERCEPTOR

SYSTEM

We Reserve All Intellectual PropertyRights In Our Products.

Tested By : SIRIM

Website : www.froscoweb.com

MR. ONGH/P : 012-549 7710

(NORTHERN)

MR. ALEXH/P : 012-713 0515

(SOUTHERN)

Email: [email protected] / [email protected]

MR. BRYANT TOHH/P : 017-8779458

(CENTRAL REGION)

MR. PETERH/P : 012-233 3861

(EAST MALAYSIA & INTERNATIONAL)

MR. ERIC ONGH/P : 016-919 9920

(CENTRAL REGION)

Double Tracking Train, Bukit Tengah Butterworth

Oil Interceptor System

General

FROSCO Oil Interceptor works on the principle that oils are lighter than water and thusgravity causes the oil to rise and the water to fall. It is designed to separate oils and otherlight density volatile liquids which are discharged into the drainage system.

In commercial establishments, the spillages of oil or diesel could occur such as garages,transport workshops, diesel re-fueling and storage areas, and where vehicles or plant arewashed down or steam cleaned.

Function

The direct and indirect discharge of oily waste water into the natural waterways has adisastrous impact on the environment.

The installation of FROSCO Oil Interceptor in drain lines will help to prevent the pollution ofrivers, streams, drainage system and water treatment plants.

Mechanical Operation of FROSCO Oil Interceptor1. Perforated Bucket Baffles Assembly

When the influent entering the interceptor, the perforated bucket baffle assemblywill trap and collect chips, particles or other sediment which are frequently presentin industrial waste and could clog the drainage system.

2. Baffles AssemblyIt will help to minimize the velocity and turbulence of the incoming waste water andpermit the oil efficiently separate and rise above the normal establishes water line ofthe interceptor.

3. Deep Seal Integral TrapThe trap is to avoid the floating oil in the interceptor being escaped out into outletdrain lines.

4. Gravity Oil Drain-off AssemblyBy automatic or manual means, the floating oil flows through an adjustable draw-offpoint to a sump or a similar storage container awaiting disposal. Please refer to‘Collection of floating oil’ column for other means of oil collection.

5. Interceptor VentsTo eliminate pressure build-up inside the interceptor, a connection on each side of theinterceptor body allows the venting of the interceptor.

FROSCO OIL INTERCEPTOR

We Reserve All Intellectual PropertyRights In Our Products.

Website : www.froscoweb.comEmail : [email protected], [email protected]

VTSB Trading1

(D)

(C)(B)

Left or right (one only)

Air relief valve

This to be cut-off gravity

flow to storage tank applicationCover in Stainless Steel also

available in Aluminium Chequer

Plate upon request only

Vent Connection

Deep seal integral trap

C/W air relief valve

Graviti falls to bottom

and being pushed out

Special baffle plate

(available only for model

FEO-300 and above)

Sediment Bucket

OUTLET

INLET

This portion to be cut-off gravity

flow to storage tank application

One layer at oil

floating on top

OUTLETINLET

Deep seal integrat trap

C/W or rebal valve

Gravity on drain

Water fall to bottom

and being pushed out

Baffle Assembly

Open handle

Vant Connection

Perforated

(E)

(D)

(F)

(A)Baffle assembly

(A)

(F)

(B) x (C)

(E)

Sediment Bucket

Water line

Static water line

H J K

G

SECTION VIEW

G

Dimensional Data :

FROSCO OIL INTERCEPTOR

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

New Model Available:-(Eg.)

FEO100/M36FEO200/M34FEO300/M49

Frosco Oil Interceptor

Code

Flowrate (GPM)

Flowrate (litre /sec)

APipe Size

(mm)

BLength(mm)

CWidth(mm)

DHeight(mm)

E(mm)

F(mm)

G(mm)

H(mm)

J(mm)

K(mm)

FEO-007 7 0.53 50 407 382 306 89 217 82 102 77 128

FEO-010 10 0.76 50 509 407 306 89 217 89 102 102 204

FEO-015 15 1.14 50 509 407 458 101 357 96 102 102 204

FEO-020 20 1.50 75 763 407 458 101 357 102 128 179 306

FEO-025 25 1.89 75 763 407 509 102 407 107 128 179 306

FEO-035 35 2.65 100 864 560 534 127 407 127 154 204 306

FE0-050 50 3.78 100 864 560 611 153 458 126 154 204 306

FEO-075 75 5.68 100 1017 814 712 152 560 140 179 255 306

FEO-100 100 7.57 100 1372 916 814 203 611 127 179 331 331

FEO-150 150 11.35 100 1526 966 961 223 738 133 179 382 382

FEO-200 200 15.14 100 1754 1093 1042 254 788 140 179 483 458

FEO-250 250 18.92 100 1880 1144 1221 281 940 140 179 483 509

FEO-300 300 22.70 150 1932 1221 1296 330 966 140 179 509 509

FEO-350 350 26.49 150 2008 1271 1347 355 992 140 179 534 534

FEO-400 400 30.28 150 2109 1398 1499 431 1068 153 179 585 585

FEO-500 500 37.84 150 2312 1526 1780 433 1347 203 179 636 636

FEO-600 600 45.41 200 2541 1830 2008 482 1526 203 179 687 687

VTSB Trading2

The design allows the introduction of any type of liquids for separation so long as there issufficient specific gravity differential to allow gravity separation.

It is must complete with baffle screen, sediment bucket and deep seal integral trap, toeffectively intercept and separate the oil from water. It achieves an average of about 99% ofoil removal for intermittent and variable flows of water, oil or any combination of non-emulsified oil / water mixtures when the hydraulic retention time (HRT) is ≥ 5 minutes.

The design must also complete with oil ‘draw off’ for channeling and separating oil to aseparate oil storage tank pending for periodic maintenance disposal.

Interceptor material : (SPECIFICATION) Date : 1-1-2016

OIL INTERCEPTOR BODY MATERIAL OIL INTERCEPTOR COVERBody Stainless steel

Non Skid AluminiumBaffle Screen Stainless steel

Integral traps Stainless steel

TYPE OF STAINLESS STEEL MATERIAL AND THE GRADE

1. Grade SUS 316 High Corrosion ResistanceUse For Waste Water TreatmentWorldwide

2. Grade SUS 304 Good Corrosion ResistanceUse For Waste Water TreatmentWorldwide

3. Grade SUS 202 Normal Corrosion Resistance Use For Architectural Decor

4. Grade SUS 439 Fair Corrosion ResistanceUse For Hot Water Heater c/w Insulation Only & Architectural Decor

5. Grade SUS 444 Fair Corrosion ResistanceUse For Architectural Décor and Hot Water Heater c/w Insulation Only

Note: Unless otherwise specified or informed in advance all FROSCO Models will be quoted with stainless steel Grade SUS439 as a basic quote in order to meet competitive market requirement by end-users / contractors etc. However FROSCO willrevise the quotation upon request to quote for an alternative grade of stainless steel material and of a different price. (ForExport market, FROSCO will only quote and supply stainless steel grade SUS 316 or 304).

OIL INTERCEPTOR FO/14 7654/16 (Page 3) dated 1/1/2016 onwards.

Specification

FROSCO OIL INTERCEPTOR

VTSB Trading3

Correct sizing of oil interceptor is important and crucial :

1. It avoids under-utilization due to excessive over-sizing.2. It avoids backflow of oily waste water due to under-sizing.3. It ensures adequate hydraulic retention time of oily waste water in the interceptor, to achieves

optimum separation of oil from water, and thus the maximum % of interception of oil.

Steps to size FROSCO Oil Interceptor :

1. Estimate the peak volume of waste water [see note i] either in liters/sec. Or Gallon/min.2. Select the oil interceptor model with flow rating equal to peak volume.3. Provide storage tank [see note ii] size sufficient to accommodate the volumes of liquids to be

having the anticipated frequency of removal.

SIZING FOR FROSCO OIL INTERCEPTOR

(A) Sizing Method[Note i] To estimate the peak volume of waste water

(1) Covered AreaPeak Flowrate : Total of hose outlets, equipments etc that continuous discharging to drain line at one

timeExample: (Waste water from washing sinks)

Sink size : 40cm x 30cm x 15cm = 18,000cc = 18 Liters

To fill up the sink with full water, and discharge it, and to check the time taken to fully discharge the water. Itis recorded the time taken is about 30 seconds. Thus, the flowrate is 18 liters/ 30 sec = 8GPM

(2) Open area (uncovered)Peak Flowrate : Total area (length(meter) x Width(meter) x Rainfalls (mm/sec.)

Example: Length = 20 meter, Width=10 meter, Rainfall = 50 mm/hourTherefore, Peak Flowrate = 20 x 10 x 50/3600 = 2.78 liters/sec.

(B) Sizing for Oil Storage Tank

[Note ii] Sizing for Oil Storage Tank1. To estimate the volume of oil into the interceptor2. Frequency of maintenance routine (once a month, twice a month, etc)3. Size the oil storage tank double the size of the total accumulated oil during the period (50% of oil

+ 50% of water) to cater for the requirements.

Example : An average of 5 liters daily of black oil is spilled and washed away into the drain lines. Assumingthat the contractor (licensed by DOE) is schedule to come and collect the waste black oil once amonths. The total black oil accumulated in 30 days time is about 150 liters. The capacity for oilstorage should be double = 300 liters.

Note : The above sizing methods are just a guideline only. In order to achieve better affluent waterrange, kindly refer to the manufacturer/supplier for further advise.

NB. OIL STORAGE TANK SIZE = 1200mm x 1200mm x 750mm (H) (15-30 DAYS – 300 L/OIL)

VTSB Trading4

Installation

FROSCO OIL INTERCEPTOR

OIL INTERCEPTOR

INSTALLATION

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

OIL INTERCEPTOR

INSTALLATION

Inlet

Vent connection

Gravity oil

draw-off connection

Adjustable gravity oil

drain-off assembly Adjustable gravity oil

drain-off assembly

Static water line

Operating

water line

Adjustable

metal tube

Pipe to oil

storage tank

Interceptor

body

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO OIL

SKIMMER

Suction line

Access cover

Draw-off line

from interceptor

Vent pipe

Concrete slab

Oil storage tank

Support bracket

FROSCO OIL

INTERCEPTOR

From floor drain

Concrete pit

Vent stack

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

Gravity

draw-off

Oil Storage Tank

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor VentVent stack

FROSCO OIL

SKIMMER

OIL INTERCEPTOR

INSTALLATION

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

OIL INTERCEPTOR

INSTALLATION

Inlet

Vent connection

Gravity oil

draw-off connection

Adjustable gravity oil

drain-off assembly Adjustable gravity oil

drain-off assembly

Static water line

Operating

water line

Adjustable

metal tube

Pipe to oil

storage tank

Interceptor

body

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO OIL

SKIMMER

Suction line

Access cover

Draw-off line

from interceptor

Vent pipe

Concrete slab

Oil storage tank

Support bracket

FROSCO OIL

INTERCEPTOR

From floor drain

Concrete pit

Vent stack

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

Gravity

draw-off

Oil Storage Tank

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor VentVent stack

FROSCO OIL

SKIMMER

VTSB Trading5

FROSCO OIL INTERCEPTOR

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

OIL INTERCEPTOR

INSTALLATION

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

OIL INTERCEPTOR

INSTALLATION

Inlet

Vent connection

Gravity oil

draw-off connection

Adjustable gravity oil

drain-off assembly Adjustable gravity oil

drain-off assembly

Static water line

Operating

water line

Adjustable

metal tube

Pipe to oil

storage tank

Interceptor

body

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO OIL

SKIMMER

Suction line

Access cover

Draw-off line

from interceptor

Vent pipe

Concrete slab

Oil storage tank

Support bracket

FROSCO OIL

INTERCEPTOR

From floor drain

Concrete pit

Vent stack

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

Gravity

draw-off

Oil Storage Tank

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor VentVent stack

FROSCO OIL

SKIMMER

OIL INTERCEPTOR

INSTALLATION

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

OIL INTERCEPTOR

INSTALLATION

Inlet

Vent connection

Gravity oil

draw-off connection

Adjustable gravity oil

drain-off assembly Adjustable gravity oil

drain-off assembly

Static water line

Operating

water line

Adjustable

metal tube

Pipe to oil

storage tank

Interceptor

body

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO OIL

SKIMMER

Suction line

Access cover

Draw-off line

from interceptor

Vent pipe

Concrete slab

Oil storage tank

Support bracket

FROSCO OIL

INTERCEPTOR

From floor drain

Concrete pit

Vent stack

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

Gravity

draw-off

Oil Storage Tank

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor VentVent stack

FROSCO OIL

SKIMMER

OIL INTERCEPTOR

INSTALLATION

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

OIL INTERCEPTOR

INSTALLATION

Inlet

Vent connection

Gravity oil

draw-off connection

Adjustable gravity oil

drain-off assembly Adjustable gravity oil

drain-off assembly

Static water line

Operating

water line

Adjustable

metal tube

Pipe to oil

storage tank

Interceptor

body

In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor Vent

FROSCO OIL

SKIMMER

Suction line

Access cover

Draw-off line

from interceptor

Vent pipe

Concrete slab

Oil storage tank

Support bracket

FROSCO OIL

INTERCEPTOR

From floor drain

Concrete pit

Vent stack

FROSCO SEDIMENT WATER DRAIN

FSWD 335 (BO/SO)

Floor drain

Gravity

draw-off

Oil Storage Tank

FROSCO OIL

INTERCEPTOR

To sewer

Interceptor VentVent stack

FROSCO OIL

SKIMMER

VTSB Trading6

Min 250mm Gap Min 250mm Gap(A)

Min 150mm Gap Min 150mm Gap

Min 150mm GapMin 150mm Gap

(B)

PLAN VIEW

INLETOUTLET

OUTLET INLET

SECTION VIEW

Ground Level

Enzyme Dosing Tube

PVC Pipe 25mmØ

INLET OUTLET

25mmØ lower than inlet

Selected Floor

Tiles As Per IDExtra Metal Cover

Steel Frame With

HDC Cover

Suspended from softfit with 4 nos

threading rod on each side and 2

nos of 2'' x 2'' angle iron

TOP VIEW

SECTION VIEW

FROSCO OIL

INTERCEPTOR

2 Pieces -Selected Floor

Tiles As Per ID

Perforated

Water line

Static water line

This portion to be cut-off gravity

flow to storage tank applicationVant Connection

(B) x (C)

(D)(F)Sediment Bucket

One layer at oil

floating on top

Deep seal integrat trap

C/W or rebal valve

Gravity on drain

Water fall to bottom

and being pushed out

FROSCO OIL INTERCEPTOR

( INSTALLATION GUIDES )

Together, Enriching Our Environment

Inside Building Installation ( Suspended )

Outside Field Installation ( Sunken )

In keeping with our policy of updating products we reserve the right

To make improvements or changes without notice.

(E)

(A)

(K)(J)(H)

Pipe Size 150mmØ Pipe Size 150mmØ

FROSCO OIL INTERCEPTOR

Top Up With 100mm

Thick Concrete

Concrete

Slab

Angle Cover

Metal

Bracket

FROSCO OIL INTERCEPTOR(INSTALLATION GUIDE)

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

VTSB Trading7

Maintenance Manual draw-off Automatic draw-off

Commissioningperiod

During the first 4 weeks of operation,regular inspection of the internalcondition of the interceptor should bemade to determine how often the oilneed to be drained off and theperforated bucket baffles assemblyemptled.

During the first 4 weeks ofoperation check the oil storagetank for build-up, and theperforated bucket bafflesassembly to determine howoften it needs to be emptled.

Routinemaintenance

Remove main cover, drain-off oil, emptyand clean perforated bucket bafflesassembly.

Remove main cover, empty andclean perforated bucket bafflesassembly.

Annual maintenance

Drain and clean interceptor tankcompletely. Check for paintworkdeterioration, and treat as required.Check joints and seal.

Drain and clean interceptor tankcompletely. Check for paintworkdeterioration, and treat asrequired. Check joints and seal.

Ensure that only OIL is taken from interceptor

1. Normally used in automatic installation with drawn-off oil collecting in storage tank. Thissetting will retain a layer of oil in the interceptor

2. If during the normal working condition, water is found entering the draw-off, adjust draw-offupward from 1/8” to ¼”.

Ensure that ALL OIL is removed from interceptor

1. Normally used with manual draw-off installation. This setting will allow water to enter thedraw-off line.

2. If during the normal working condition, oil is found to be remaining in the interceptor :• For manual installation : Draw-off oil more frequently and or lower draw- off by

another 1/8”.• For automatic installation : Lower draw-off by another 1/8”.

Maintenance

VTSB Trading8

FROSCO Oil Interceptor system has been tested by SIRIM (SIRIM ref. no : 237/16/119).According to the test result, FROSCO Oil Interceptor achieves 99% oil removal when thehydraulic retention time (HRT) is about 5 minutes. It concludes that FROSCO Oil Interceptor canbe seen as a pretreatment system that can help reduce the negative impact to theenvironment.

COLLECTION OF FLOATING OIL FROM FROSCO OIL INTERCEPTOR

Method (I)1. Manual scoop, periodically - Periodically, the floating oil in the interceptor is to be scoop

and cleaned away.2. Gravity flow to oil storage tank.3. Automatic skimming by oil skimmer - Setting of oil skimmer to skim floating oil in the

interceptor on regular basis.

Collection of floating oil by Oil Storage Tank

( Method II )1. Frosco Oil Interceptor is suitable for floor standing or recessed installation.2. Vent and draw-off connections are provided on both sides of the interceptor for ease of

installation and use. All connection points not used must be sealed.3. To receiving container. For automatic operation, use storage tank. For manual operation,

any suitable container may be used.4. Oil level detector (upon request) which is giving signal for period maintenance can be

installed in the oil storage tank.

SIRIM TEST

VTSB Trading9

BELT TYPE SKIMMER

For Use With :•Metalworking Coolants•Parts Washer Fluids•Wastewaters•Pressure Spray Water•Water Treatment System

Mini-Skimmer have been in use through outthe world since 1980. Thousand are useddaily to remove unwanted floating or ‘ tramp’oil.

They are small, run very quietly, and use avery dependable permanent magnet motor.Standard models for industrial users includeoil pick-up rate to 4 gallons/hour, loose orfixed tail pulley design, and a choice ofpolyurethane ( for coolants & oil/water ) orstainless steel ( for part washing ) belts in foursizes.

Special skimmer with other options such asspecial belt lengths ( to 20 ft ), two belts,stainless motor covers.

FEATURES & CHOICE• Lifts 1 quart to 4 gallons per hour!• Polyurethane belts for coolants!• Stainless steel belts for partswashers!• Four standard belts lengths!• Special belt lengths to 20 ft.• Loose or fixed tail pulley system!• Mounts on vertical / horizontal surfaces!• World’s smallest!• Fits in tiny spaces!• Dependable permanent magnet motor!• Steel or stainless wetted parts!

Collecting of floating oil by Oil Skimmer( Method III ).

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

OIL SKIMMER WAYNEMade in USA

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading10

BELT TYPE SKIMMER

Economy Oil Skimmer For CoolantsModel DBS

The Motor : High quality, quiet & dependable permanentmagnet motor with stainless steel sheath & sixft. cord. 115v with USA type three prong plug,220v with Euro two prong plug.

The Belt : 1” wide flat polyurethane belt has greatadherance for floating oils. Two standardlengths - 8” or 12” from mounting bracketbase to the lowest point.

Oil Pick-up : A choice! 10rpm will lift approx. 1 quart perhour. 30rpm collects approx. 7 quarts perhour.

The Other : Nylon drive pulley, stainless steel mountingbracket & scraper / trough assembly. Steel tailpulley and supporting bar (holds tail pulley inplace).

Warranty : One year, from shipment to user, coveringmanufacturing defects only.

Use For : Coolants, other oil / water applications inwastewater or water treatment below 120F.Not for use with parts washers.

Parts

Model Number Reach Lift Rate

USA WorldwideWith CE

Mark

115/1/60 115/1/60 220/1/50 220/1/50

DBS-10-270P1-FTPS 8” 1qt./hr 37800 31680 31685 31695

DBS-10-360P1-FTPS 12” 1gal./hr 37805 31681 31686 31698

DBS-30-270P1-FTPS 8” 7qts./hr 37810 31882 n/a n/a

DBS-30-360P1-FTPS 12” 7qts./hr 37820 31883 n/a n/a

Model DBS answers the world’s needs for high quality, low cost belt oil skimmer for metalworking coolants!

Note : Belt lengths can be easily made for reaching from 2” to 50ft!

Belt “Reach”This is the distance from the mounting bracket base to the lowest point

Overall Dimension8” reach 13” H x 4” W x 5” D

12” reach 17” H x 4” W x 5” D

Weight5.5 Ibs. Individually boxed

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading11

1” Wide Belt Skimmers for Use With Metalworking COOLANTS and Wastewater Applications

Many Thousands of Mini-SkimmersTM have been used throughout theworld since 1990 for removing tramp oils from coolants andwastewaters. There are choices of polyurethane belt – cog type on MSB& lower cost Flat Type on Model DBS, with five choices on standard“reach” lengths & two oil collection rates. Custom units can be built withstainless steel metal parts and belts.

• 5 Belt Reach Choices From 5” to 24” Down!• Choices of Cogged or Flat Polyurethane Belt!• Steel Stabilizer Bar Holds Tail Pulley in place!• Dependable, Quiet Permanent Magnet Motor!• Choices of 1 Qt (ltr) or 1 Gal. (4 ltrs) per Hour!• Small Size – Fits Almost Anywhere!• Thousands Sold Worldwide Since 1990!

Select Order Number For Cost InquiryMODEL MSB – Cog Polyurethane BeltCOLLECTION RATE1 Quart or Liter per Hour 1 Gallon or 4 Liters per Hour

Reach 115/1/60 220/1/50/CE 115/1/60 220/1/50/CE

8” 31820 31700 31825 31716

12” 31821 31701 31825 31717

18” 31822 31702 31827 31718

24” 31823 31703 31828 31719

Reach 115/1/60 220/1/50/CE 115/1/60 220/1/50/CE

5” 37802 31692 37803 31707

8” 31680 31695 31882 31697

12” 31681 31696 31883 31698

18” 31682 31694 31884 31699

24” 31683 31693 31885 31705

MODEL DBS – Flat Polyurethane BeltCOLLECTION RATE1 Quart or Liter per Hour 1 Gallon or 4 Liters per Hour

MOTORS are permanent-magnet typewith SS sheath cover & 6 ft. cordset115/1/60 – 0.0065 amp 220/1/50/CE –0.05 amp draw. Stainless steelmounting bracket & scraper/ troughassy. Steel tail pulley & stabilizer barnylon drive pulley. Max, suggestedtemp – 120 F (50oC) – Ship wt 5-9 Ibs.1 year warranty against manufactureddefects. Belts Warranted 90 days forbreakage only. Further warranty detailson request.

Manufacturers of Oil Skimmers, Blowers and Filter/ Ventilator Systems

MSBCog Belt

DBSFlat Belt

MOTOR

4 1/4"

4 5/8"

BELT

REACH 3 1/4" Wide

From Front

TROUGH

Mounting Surface

TA

IL P

UL

LE

YB

EL

TD

RIV

E P

UL

LE

Y

3 /4"

1"

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading12

For Central Coolant Systems and wastewater/ Water treatment SystemsMAXI- SkimmersTM are a recent development to provideindustry with an economical, corrosion-free, wide beltskimmer for central coolant tanks, wastewater and watertreatment applications with collection rates from 2.5 to 10gallons per hour. Economy is gained by using manycomponents which are purchased in volume for other designs!

Benefits!Economical cost and Dependable Operation!Choice of 2.5, 5.0 or 10 Gallons per Hour Collection!Std Belt Lengths to 10 ft. – Can be made to 50ft. down!Handles Fluctuating Liquid Levels!No Corrosion – All Stainless Polymer Materials!Takes Little space & is easy to install!Furnished as a complete System with Accessories!

Features!Uses 2 – 4” wide Polyurethane or Stainless Steel Belt!Uses Quiet & Dependable Hurst Permanent Magnet Motor!UHMW Bearing-Grade Polymer Sraper Blade!Choice Of three Standard Collection Rates!Nice Appearance!1 Year Limited Warranty!

Accessories (Included)!Timer For Automatic Control – Three Settings/ 24 Hrs!Ground Fault Interrupter for Electrical Safety!3 Foot Oil Outlet Extension Hose!

TechnicalMotor : 115/1/60, 30 rpm, cont. dutyCordset : 6 ft. three prong.Amp. Draw : 0.65 (7 watts)Frame : Stainless Steel & UHMW endsCollects : 2.5, 5 or 10 Gph.Temp. : 120 F. Max (with poly belt).Ship Weight : 15 – 30 Ibs.

Optional Accessories.Adjustable stand for drum collection.Diverter for oil/water separation.Handle for portability.

Modifications Include 220vac. 12-24 vdc motors. Collection rates. Stainless steel belt and belt reaches to 50 ft.

Manufacturers of Oil Skimmers, Blowers and Filter/Ventilator Systems

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading13

1. To fill up the FROSCO Oil Interceptor with clean water, free of oil, dirt or othercontaminants when it is properly installed.

2. The amount of debris such as sand, gravel, dirt, leaves, grass cutting, etc, permittedto enter the system must be minimized. Sediment bucket should be inspected andcleaned on daily/ weekly / biweekly basis depending on the incoming volume.

3. The floating oil (oil trapped) in the interceptor should be cleaned on daily/ weekly /biweekly basis depending on the incoming volume.

a) Manual Scoop (Method I)To scoop the floating oil manually on regular basis.

b) Oil Storage Tank (Method II)Refer to column on the oil storage tank application.

c) Oil Skimmer (Method III)Oil Skimmer is pre-set to run on daily / weekly basis for certain time duration(depend on oil content) to skim up the floating oil and channel it to aseparate oil container awaiting for disposal.

Operating Manual

To assure maximum effectiveness of the system, certain precautions should be observed.1. The amount of debris such as sand, gravel, dirt, leaves, grass cuttings, etc., permitted

to enter the system must be minimized. Perforated bucket of the sediment trapbefore the interceptor should be inspected and cleaned on a regular basis.

1. Automotive and truck engine crankcase oil should not be drained into the systemsludge and deposits present in the oil will significantly reduce the effectiveness ofthe interceptor.

1. Hydrocarbons entering the separator will be in a free non-emulsified state andcapable of being separated from water in a gravity separator.

1. Detergents have a definite affinity for hydrocarbons. Wash water from truck washingracks must be routed directly to a sanitary sewer or treated with special equipment.Water containing detergents must not be allowed to enter the system, unless thedetergents is biodegradable.

1. Water flow rates are within the specification. Adequate water retention time willensure proper separation of oil/ water mixture.

A flow controller is advisable to install at the upstream of the unit to ensure no accidentaldischarge of oil during periods of excessive wastewater flow.

Steps To Further Improve Effectiveness

VTSB Trading14

Model Photo Model Photo

FOS-50BELT SKIMMER

FFS-1BFLOATING SKIMMER

FOS-50BBELT SKIMMER

FFS-2FLOATING SKIMMER

FOS-50NBELT SKIMMER

FWOS-300POLYMER WHEEL SKIMMER

FOS-50N-PVCBELT SKIMMER

FTB-80BELT SKIMMER

FNC-40BELT SKIMMER

FOS-2BELT SKIMMER

Type Of Frosco Oil Skimmer

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading15

Model Photo Model Photo

FWOS-300A400POLYMER WHEEL SKIMMER

FOS-4BELTSKIMMER

FWOS-300BPOLYMER WHEEL SKIMMER

FWOSPOLYMER WHEEL SKIMMER

FFS-1FLOATING SKIMMER

FFSCL-A-AIR-1POLYMER WHEEL SKIMMER

FFS-5POLYMER WHEEL SKIMMER

FFSCL-ELDC-1POLYMER WHEEL SKIMMER

Type Of Frosco Oil Skimmer

(FOR THE SERVICE AND MAINTENANCE USE)

VTSB Trading16

WORKSHOP (HANDWASH SINK)

OIL SKIMMER SYSTEM (CARPARK)

VTSB Trading17

Model Photo Model Photo

FM-100-1RS FM100-6RS

FM-100-2RS FM100-8RS

FM-100-4RS FM100-10RS

Type Of Frosco Oil Cleaner

(FOR THE CLEANING, SERVICE AND MAINTENANCE USE)

VTSB Trading18

VTSB Trading19

FROSCO PRODUCTS ALWAYS COME WITH REGISTERED TRADE MARK, MODEL AND SERIAL NUMBER IN EVERY UNIT SUPPLIED.

1. Stainless steel body ( paint sprayed FROSCO trade mark ) – both side2. Stainless steel cover ( embossed FROSCO trade mark ) – both covers3. Next to dosing hole a pieces of PVC Plate with FROSCO trade mark, model and serial number.

4. Hydrafilter Baffle ( embossed FROSCO trade mark and serial number ).

FROSCO Oil Interceptor

Model : xxxxSerial Number : xxxx

Note : We reserve all the rights to take up legal action againt those who copy our product and registeredTRADE MARK.

VTSB Trading20

SEDIMENT WASTE DRAIN

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

300mm

300mm

300mm

Top Access

Hinged Grating

Stainless Steel

Bucket

Removable

Bell Trap

Pipe size

75mmØ/ 100mmØ/ 150mmØ

300mm

300mm

300mm

Top Access

Hinged Grating

Stainless Steel

Bucket

OUTLET

OUTLETPipe size

100mmØ

Sediment Waste Drain

Model : FSWD 335 BO

Bottom Outlet

Sediment Waste Drain

Model : FSWD 335 SO

Side Outlet

100mm

200mm

VTSB Trading21

FROSCO HF OIL SEPARATOR SYSTEM(HEAVY FLOW OIL SEPARATOR)

(COMPLETE WITH SKIMMER FILTRECEPTOR OR DETERGENTCEPTOR SYSTEM)

( GREY WATER )

VTSB Trading22

Frosco Oil Separator Code

Flowrate(GPM)

Flowrate (litre/sec)

APipe Size

(mm)

BLength(mm)

CWidth(mm)

DHeight(mm)

E(mm)

F(mm)

FEO-300 (OCBV)-IP 300 22.70 150 3000 1221 1296 330 966

FEO-350 (OCBV)-IP 350 26.49 150 3000 1271 1347 355 992

FEO-400 (OCBV)-IP 400 30.28 150 3000 1398 1499 431 1068

FEO-500 (OCBV)-IP 500 34.05 150 3000 1526 1780 433 1347

FEO-600 (OCBV)-IP 600 37.84 200 3000 1830 2008 482 1526

Frosco Oil Separator Code

Flowrate(GPM)

Flowrate (litre/sec)

APipe Size

(mm)

BLength(mm)

CWidth(mm)

DHeight(mm)

E(mm)

F(mm)

FEO-300 (OCBV)-IP 300 22.70 150 3000 1221 1296 330 966

FEO-350 (OCBV)-IP 350 26.49 150 3000 1271 1347 355 992

FEO-400 (OCBV)-IP 400 30.28 150 3000 1398 1499 431 1068

FEO-500 (OCBV)-IP 500 34.05 150 3000 1526 1780 433 1347

FEO-600 (OCBV)-IP 600 37.84 200 3000 1830 2008 482 1526

Frosco Oil Separator Code

Flowrate(GPM)

Flowrate (litre/sec)

APipe Size

(mm)

BLength(mm)

CWidth(mm)

DHeight(mm)

E(mm)

F(mm)

FEO-300 (OCBV)-EP 300 22.70 150 3000 1221 1296 330 966

FEO-350 (OCBV)-EP 350 26.49 150 3000 1271 1347 355 992

FEO-400 (OCBV)-EP 400 30.28 150 3000 1398 1499 431 1068

FEO-500 (OCBV)-EP 500 34.05 150 3000 1526 1780 433 1347

FEO-600 (OCBV)-EP 600 37.84 200 3000 1830 2008 482 1526

Frosco Oil Separator Code

Flowrate(GPM)

Flowrate (litre/sec)

APipe Size

(mm)

BLength(mm)

CWidth(mm)

DHeight(mm)

E(mm)

F(mm)

FEO-300 (OCBV)-EP 300 22.70 150 3000 1221 1296 330 966

FEO-350 (OCBV)-EP 350 26.49 150 3000 1271 1347 355 992

FEO-400 (OCBV)-EP 400 30.28 150 3000 1398 1499 431 1068

FEO-500 (OCBV)-EP 500 34.05 150 3000 1526 1780 433 1347

FEO-600 (OCBV)-EP 600 37.84 200 3000 1830 2008 482 1526

FROSCO HF OIL SEPARATOR - (OCBV Series) - Model : EP & IP

(D)

This portion to be

cut-off gravity

flow to storage tank

application

One layer at oil

floating on top

OUTLET

INLET

Deep seal

integrat trap

C/W or rebal valve

Gravity on drain

Water fall to

bottom and

being pushed out

(A)

(F)

(B) x (C)

(E)

Ball Gate

Valve

3000 mm

2008 mm

3000 mm X 1830mm

FROSCO HF OIL SEPARATORMODEL : FEO-600 (OCBV)-EP

(OVER FLOW CONTROL BALL VALVES)- EXTERNAL FLOW

SIZE : (3000 x 1830 x 2008H)

HF : Heavy Flow

(D)

This portion to be

cut-off gravity

flow to storage tank

application

(F)

(B) x (C)

(E)

3000 mm

2008 mm

3000 mm x 1830mm

FROSCO HF OIL SEPARATORMODEL : FEO-600 (OCBV)-IP

(OVER FLOW CONTROL BALL VALVES)- INTERNAL FLOW

SIZE : (3000 x 1830 x 2008H)

HF : Heavy Flow

(A)

OUTLET

One layer at oil

floating on top

Deep seal

integrat trap

C/W or rebal valve

Gravity on drain

Water fall to

bottom and

being pushed out

Ball Gate

Valve

37.84

45.41

37.8445.41

VTSB Trading23

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

FROSCO OIL SEPARATOR SYSTEM(XL) - MODEL : SFD/FMB/FBD

TABLE

NO FROSCO SKIMMING / OIL SEPARATOR (MODEL SFD) FILTER CEPTOR ( MODEL FMB) BIO-DETERGENCEPTOR (MODEL FBD)

1 MODEL SFD 1115XL MODEL FMB 1115 MODEL FBD 1115

SIZE : 2026 x 966 x 961 (H) 2000 x 1000 x 1500 (H) 2000 x 1000 x 1500 (H)

2 MODEL SFD 1125XL MODEL FMB 1125 MODEL FBD 1125

SIZE : 2380 x 1144 x 1221 (H) 2500 x 1350 x 1500 (H) 2500 x 1350 x 1500 (H)

3 MODEL SFD 1135XL MODEL FMB 1135 MODEL FBD 1135

SIZE : 2508 X 1271 X 1347 (H) 2650 x 1650 x 1500 (H) 2650 x 1650 x 1500 (H)

4 MODEL SFD 1145XL MODEL FMB 1145 MODEL FBD 1145

SIZE : 2812 x 1526 x 1780 (H) 3000 x 1850 x 2000 (H) 3000 x 1850 x 2000 (H)

5 MODEL SFD 1160XL MODEL FMB 1160 MODEL FBD 1160

SIZE : 3041 x 1830 x 2008 (H) 3000 x 2550 x 2200 (H) 3000 x 2550 x 2200 (H)

Oil / Grease

Skimmer

Plug Point

Skimmer Timer

FROSCO OIL SKIMMER

C/W Trolly & Separator

Model : FIS/SSV/P 2-100 US

Skimmer

Belt

Water Level

BIODETERGENTCEPTORSKIMMER

OIL SEPARATOR

BASEMENT

FROSCO AUTOMATIC

DOSING UNIT

Plug Point

13amp

TREATMENT

PRODUCT

Sensor

GREASE INTERCEPTOR

C/W FILTRATION SYSTEM

OUTLET

Manhole

OIL BARREL

PUMP

FOR BASEMENT USE

SKIMMER

OIL SEPARATOR

GPT

(Gross Pollutant Trap)

Skimmer

Belt

Oil / Grease Collection Tank

(Optional)

Oil / Grease

Skimmer

Plug Point

Skimmer Timer

Trolley

(Optional)

Water Level

Ground Level

SECTION VIEW

Air Vent Pipe Air Vent Pipe

MANHOLE

or

DRAIN

Plug Point

13amp

TREATMENT

PRODUCT

Note : INSTALLATION GUIDES

BIODETERGENTCEPTOR

MANHOLE

or

DRAIN

BIODETERGENTCEPTOR

GPT

(Gross Pollutant Trap)

ADU

PUMP

PLAN VIEW

SKIMMER

OIL SEPARATOR

Oil SkimmerOil Separator Pipe

Overflow Pipe

Overflow Pipe

FROSCO OIL SKIMMER

C/W Trolly & Separator

Model : FIS/SSV/P 2-100 US

Oil Separator Pipe

FROSCO AUTOMATIC

DOSING UNIT

Collection Sump Pit c/w Strainer Basket

Collection Sump Pit c/w Strainer Basket

VTSB Trading24

Collection Sump Pit or

GPT (Gross Pollutant Trap)

c/w Strainer Basket

Skimmer

Belt

Oil / Grease Collection Tank

(Optional)

Oil / Grease

Skimmer

Plug Point

Skimmer Timer

Trolley

(Optional)

Water Level

Ground Level

SECTION VIEW

Air Vent Pipe Air Vent Pipe

MANHOLE

Plug Point

13amp

TREATMENT

PRODUCT

MANHOLE

ADU

PUMP

PLAN VIEW

Oil SkimmerOil Separator Pipe

Frosco Oil

Separator c/w Oil

Skimmer

Frosco multiple wall

Detergenceptor c/w ADU

Treatment Chemical

Product

Frosco Oil Separator c/w Multiple Wall Detergenseptor System (For External Use)

FROSCO AUTOMATIC

DOSING UNIT

FROSCO OIL SKIMMER

C/W Trolly & Separator

Model : FIS/SSV/P 2-100 US

Collection Sump Pit or

GPT (Gross Pollutant Trap)

c/w Strainer Basket

Frosco Oil

Separator c/w Oil

Skimmer

Frosco multiple wall

Detergenceptor c/w ADU

Treatment Chemical

Product

FROSCO OIL SEPARATOR C/W MULTIPLE WALL

DETERGENCEPTOR SYSTEM (FOR EXTERNAL USE)TABLE :

See for view (One Complete Set System)

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

NO FROSCO OIL SEPARATOR C/W OIL SKIMMER (A) FROSCO MULTIPLE WALL DETERGENCEPTOR COMPLETE SET

C/W ADU TREATMENT CHEMICAL PRODUCT (B)

1 MODEL : FOSS 0300XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0300XXL+(ADU & TREATMENT CHEMICAL) (A+B)

SIZE : 2026mm (L) x 966mm (W) x 961mm (H) SIZE : 2000mm (L) x 1000mm (W) x 1500mm (H) C/Set

2 MODEL : FOSS 0350XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0350XXL+(ADU & TREATMENT CHEMICAL) (A+B)

SIZE : 2380mm (L) x 1144mm (W) x 1221mm (H) SIZE : 2500mm (L) x 1350mm (W) x 1500mm (H) C/Set

3 MODEL : FOSS 0400XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0400XXL+(ADU & TREATMENT CHEMICAL) (A+B)

SIZE : 2508mm (L) x 1271mm (W) x 1347mm (H) SIZE : 2650mm (L) x 1650mm (W) x 1500mm (H) C/Set

4 MODEL : FOSS 0500XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0500XXL+(ADU & TREATMENT CHEMICAL) (A+B)

SIZE : 2812mm (L) x 1526mm (W) x 1780mm (H) SIZE : 3000mm (L) x 2300mm (W) x 1800mm (H) C/Set

5 MODEL : FOSS 0600XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0600XXL+(ADU & TREATMENT CHEMICAL) (A+B)

SIZE : 3041mm (L) x 1830mm (W) x 2008mm (H) SIZE : 3000mm (L) x 2550mm (W) x 2200mm (H) C/Set

FROSCO OIL SEPARATOR C/W MULTIPLE WALL DETERGENCEPTOR SYSTEM (FOR EXTERNAL USE)

TABLE

Collection Sump Pit c/w Strainer Basket

Collection Sump Pit c/w Strainer Basket

VTSB Trading25

Wate

r R

eta

inin

g P

on

d

Wate

r R

eta

inin

g

Po

nd

in

flu

en

tp

ara

mete

r m

ay

req

uir

e t

oco

mp

ly t

o

rele

van

tau

tho

rity

's

reg

ula

tio

n &

gu

ide lin

e

Sele

cte

d O

ilIn

terc

ep

tor

sh

ou

ld b

e a

ble

to r

em

ove O

& G

in h

igh

est

rem

oval

eff

icie

ncy in

th

e

perc

en

tag

e 9

9%

on

ly

Oil In

terc

ep

tor

FE

O 6

00

Eff

ecte

d s

erv

ice a

rea

on

ly C

/W 3

00 x

200

Scu

pp

er

Dra

in A

rou

nd

Sg

.

(Riv

er)

Air

cra

ft S

erv

ice a

nd

Park

ing

are

a

(Wate

r je

t +

Rain

fall (

1st

Wash

)

at

acfe

cte

d a

rea o

nly

)

Oil In

terc

ep

tor

FE

O 6

00

Oil In

terc

ep

tor

FE

O 6

00

Oil In

terc

ep

tor

FE

O 6

00

OP

EN

AR

EA

FR

OS

CO

OIL

IN

TE

RC

EP

TO

R

SC

HE

MA

TIC

PL

AN

In k

eep

ing

wit

h o

ur

po

licy o

f u

pd

ati

ng

pro

du

cts

we r

eserv

e t

he r

igh

t to

make im

pro

vem

en

t o

r ch

an

ges w

ith

ou

t n

oti

ce.

CO

VE

RE

D W

OR

K S

HO

P

(SE

RV

ICE

& M

IAN

TE

NA

NC

E)

( L

x W

)

( L

x W

)

Oil In

terc

ep

tor

200 G

pm

Oil In

terc

ep

tor

300 G

pm

Bo

ein

g 7

47

Serv

ice

Bo

ein

g 7

37

Serv

ice FW

D 3

35

Waste

Dra

in

FW

D 3

35

Waste

Dra

in

AIR

PLA

NES

SE

RV

ICE

CEN

TRE

VTSB Trading26

Unknown

FR

OSC

O O

IL S

KIM

ME

RS

EPA

RA

TO

R

CO

LL

EC

TIO

N S

UM

P P

ITc/w

S/S

TE

EL B

AS

KE

T

FR

OSC

O M

UL

TIP

LE

WA

LL

DET

ER

GE

NC

EP

TO

R

Skim

me

r B

elt

Oil / G

rease C

ollectio

n T

an

k(O

ptional)

Oil

/ G

rease S

kim

merP

lug P

oin

t

Skim

mer T

imer

Tro

lley

(Optional)

Pro

po

se 'E

' D

imensio

n S

ubje

ct

To Inle

t P

ipe G

radie

nt

Gro

und L

evel

SE

CT

ION

VIE

W

Air V

ent

Pip

eW

ate

r Le

vel

Subm

ers

ible

Pu

mp

Sensor

SC

UP

PE

R D

RA

ING

round L

evel

In k

eep

ing

wit

h o

ur

po

lic

y o

f u

pd

ati

ng

pro

du

cts

we

res

erv

e t

he r

igh

t to

ma

ke i

mp

rov

em

en

t o

r ch

an

ge

s w

ith

ou

t n

oti

ce.

FR

OS

CO

AU

TO

MA

TIC

DO

SIN

G U

NIT

Plu

g P

oin

tP

lug P

oin

t

Unknown

Pro

pose 'E

' D

imensio

n S

ubje

ct

To Inle

t P

ipe G

radie

nt

Wate

r Level

Wa

ter

Level

TR

EA

TM

EN

T P

RO

DU

CT

Sc

upp

er

Dra

in

Ra

il T

rac

k

Cu

rve

On

- B

oth

Sid

e(T

o p

reve

nt

rain

wat

er

fro

m o

the

r a

rea

to

Oil

Inte

rce

pto

r A

rea

)

Tra

in

To

Col

lec

tion

Su

mp

Pit

Deta

ilin

g

30

000

mm

(L

) x

50

00

mm

(W

)

VTSB Trading27

Ma

nh

ole

or

Re

levan

t

Au

tho

rity

's

Ad

vis

e

SE

CT

ION

VIE

W

Solid

Waste

Dra

in

(SW

D)

GP

T

Oil I

nte

rce

pto

r

(Fro

sco)

WA

ST

E W

AT

ER

RE

TE

NT

ION

PO

ND

(Ma

yb

e R

eq

uir

e t

o b

e P

retr

eate

d)

CO

VE

RE

D W

OR

K S

HO

P

(SE

RV

ICE

& M

AIN

TE

NA

NC

E)

FR

OS

CO

OIL

IN

TE

RC

EP

TO

R

GP

TG

PT

GP

T

Und

er

Sin

k O

il

Inte

rce

pto

r

GP

T

BU

S P

AR

KIN

G A

RE

A (

OP

EN

)

In k

eep

ing

wit

h o

ur

po

licy

of

up

dat

ing

pro

du

cts

we

res

erve

th

e ri

ght

To m

ake

imp

rove

men

ts o

r ch

ange

s w

ith

ou

t n

oti

ce.

SOLI

D

WA

STE

SUM

P P

IT

SOLI

DW

AST

ESU

MP

PIT

SOLI

D

WA

STE

SUM

P P

IT

SOLI

D

WA

STE

SUM

P P

IT

SOLI

D

WA

STE

SUM

P P

IT

VTSB Trading28

EXTERNAL OPEN AREA

FROSCO HF OIL INTERCEPTOR AND SOLID POLLUTANT STRAINER (BASKET) MODEL: FEO-600 (OCBV)-EP

VTSB Trading29

VTSB Trading30

N.B. All Intellectual Property Rights Reserved

ENVIRONMENT QUALITY ACT 1974

SEWAGE AND INDUSTRIAL EFFLUENTS REGULATIONS

First ScheduleList of discharge to which these regulations do not apply :

1) Processing of oil-palm fresh fruit bunches into crude palm oil, whether as an intermediate or final product.2) Processing of natural rubber in technically specified from latex form including prevulcanized or the form of

modified and special purpose rubber, conventional sheet, skim, crepe or scrap rubber.3) Mining activities.4) Processing manufacturing, washing or servicing of any other products or goods :

• That produce effluent of less than 60 cubic meter ( 13,000 imperial gallons ) per day,• That the effluent of which does not contain those contaminants listed as parameters (vi) to (xvi) in the first

column of the Third Schedule,• Where the total load of biochemical oxygen demand of the effluent fixed at 20 degree Centigrade for 5 days

or suspended solid or both, shall not exceed 6 kilograms per day ( concentration 100 milligrams per liter),• In any housing or commercial development or both of less than 30 units, without affecting the generality of

the © above.

Second ScheduleStandard methods of Analysis of Effluent

1) “Standard Methods of examination of Water and Waste Water“ published jointly by the American Public HealthAssociation, an American Water Works Association and the Water Pollution Control Federation of the UnitedStates, or

2) “Analysis of Raw, Potable and Waste Waters“ published by the Department of the Environment of the UnitedKingdom.

Third ScheduleParameter Limit of Effluent of Standard A and B :

No PARAMETER UNITSTANDARD

A BI Temperature C 40 40ii pH Value - 6.0-9.0 5.5-9.0iii BOD at 20C mg/L 20 50iv COD mg/L 50 100v Suspended Solids mg/L 50 100vi Mercury mg/L 0.005 0.05vii Cadmium mg/L 0.01 0.02viii Chromium, Hexavalent mg/L 0.05 0.05ix Arsenic mg/L 0.05 0.10x Cyanide mg/L 0.05 0.10xi Lead mg/L 0.10 0.50xii Chromium, Trivalent mg/L 0.20 1.00xiii Copper mg/L 0.20 1.00xiv Manganese mg/L 0.20 1.00xv Nickel mg/L 0.20 1.00xvi Tin mg/L 0.20 1.00xvii Zinc mg/L 2.00 2.00Xviii Boron mg/L 1.00 4.00xix Iron (Fe) mg/L 1.00 5.00xx Phenol mg/L 0.001 1.00xxi Free Chlorine mg/L 1.00 2.00xxii Sulphide mg/L 0.50 0.50xxiii Oil and Grease mg/L Not Detected 10.00

VTSB Trading

31

Existing sewage treatment system (approved after January 1999)All sewerage treatment system which were approved after the Guidelines for Developers : SewerageTreatment Vol. IV, 2nd edition and were enforced by Department of Sewerage Services, Ministry of Housingand Local Government, beginning January 1999 and up to the date of coming into operation of theseregulations.

Note :Standard A is applicable to discharge into any inland waters within catchment areas listed in the ThirdSchedule, while Standard B is applicable to any other inland waters or Malaysian waters.

ENVIRONMENT QUALITY (SEWAGE)

REGULATIONS 2009

PARAMETER UNITSTANDARD

A B

(1) (2) (3) (4)

a) BOD5 at 20oC mg/L 20 50

b) COD mg/L 120 200

c) Suspended Solids mg/L 50 100

e) Oil and Grease mg/L 20 20

f) Ammoniacal Nitrogen mg/L 50 50

VTSB Trading32

Double Tracking Train, Bukit Tengah Perak

Oil Interceptor System

Founded Year 1986

Over 38 years experience in the Building, Construction &

Property Industry

Pioneer of Biomatic Grease Interceptor System in Malaysia

Collaborated with SIRIM (Standard and Industrial

Research Institute of Malaysia) to conduct the 1st test

analysis on the Biomatic Grease Interceptor with the

highest efficiency result in Malaysia

Our own research, design & manufacturing facilities.

One stop center for developers, architects, design

engineers & contractors for their building materials needs

Long track record & excellent service by our team of

competent and capable technicians

We provide high technical expertise & advice

Consultancy & design for environmental protection

related projects

Some of the past projects we have participated & supplied

to :

KOMTAR, Georgetown, Penang

Kuala Lumpur International Airport (KLIA)

Petronas Twin Towers (KLCC)

Kuala Lumpur Tower

Sepang International Circuit (SIC), Formula 1 Racing

(F1)

National Palace, Duta Road, Kuala Lumpur, Malaysia

Port Klang Free Trade Zone

Mid Valley City, Kuala Lumpur, Malaysia

KTM (Keretapi Tanah Melayu, Malayan Railway)

National Double Tracking & Electrification Project.

www.froscoweb.com

COPYRIGHT VTSB Trading (149888-v)

GREYWATEC ENGINEERING SDN. BHD

In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.

ASSOCIATED BRAND :

WELL ESTABLISHED BRANDS IN GREASE / OIL AND WASTE

WATER MANAGEMENT SYSTEM FOR THE PROJECTS IN

THE MARKET