electron spectrometer progress report simon jolly 19 th october 2012
TRANSCRIPT
Electron Spectrometer
Progress Report
Simon Jolly19th October 2012
Spectrometer Specifications
• Wakefield accelerated electrons ejected collinear with proton beam: need to separate the 2 and measure energy of electron beam only.
• Must be able to resolve energy spread as well as energy: spectrometer must accept a range of energies, probably 0-5 GeV.
• Current conceptual layout:– Dipole mounted ~2 m of plasma exit induces
dispersion in electron beam.– Scintillator screen 1 m downstream of dipole
intercepts electron beam ONLY.– Dispersion gives energy-dependent position spread
on screen.– Scintillator imaged by intensified CCD camera
viewing upstream face of scintillator screen.
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
2
Spectrometer Layout
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
3
Camera
Scintillator ScreenCERN 1 m dipole
Plasma cell
Protons
Electrons + Protons
• Edge of scintillator screen is aligned with dipole coils (position will depend on resolution).
• Screen mounted at 45 degrees to beam axis.• Camera is 4 m from centre of screen, mounted at
90 degrees to beam axis.• Camera shown in horizontal bending plane.• Camera can also be mounted vertically, directly
above screen, with screen tilted at 45 degrees to vertical as well as 45 degrees to beam axis. Dipole to screen distance remains unchanged (independent of screen-camera orientation).
Electron Trajectories (Alexey)
19/10/12 4Simon Jolly, UCL, AWAKE Collaboration Meeting
With Quadrupole Doublet (Alexey)
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
5
CERN 1 m Dipole (Edda, Alexey)
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
6
Scintillator Alternatives
• Concerns expressed at last phone meeting over quantity of light emitted for low numbers of electrons.
• Also problems with unwanted particles:– Lots of crap ejected from plasma along
with accelerated electron.– Bremsstrahlung production in dipole.
• Do we need to look for an alternative technology to optimise spectrometer?
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
7
Stray Particle Hits• The screen sits downstream of >1 m of iron dipole magnet yoke.
– Low energy side of the screen should be well shielding.– High energy side – closer to proton beam – more exposed.
• Add collimators upstream of dipole to reduce the particle flux reaching the screen.
• Add some additional shielding upstream of the dipole if space (no quadrupole doublet).– Need some input on particle species at plasma exit.– How much shielding do we need?
• Bremsstrahlung production within dipole unavoidable, but unlikely to be significant background given low numbers of electrons.– Also check with simulation.
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
8
Collimators
Dipole
Protons + collinear crap
Electrons + bremsstrahlung photons
Sensitive Electron Detection• SEM Grid/Harp:
– Secondary emission of electrons within wires gives beam intensity at transverse beam location.
– Reconstruct 1-D intensity profile.– VERY small spatial coverage (eg.
100 micron wires at 5mm spacing): we need ~100% coverage…
• Drift chamber:– Many wires suspended inside
gaseous medium at high voltage.– Could give 100% coverage– Sample the beam at regular
intervals by integrating the current along each wire.
– Timing not an issue since we have single very short beam pulse.
– Too many particles to do proper tracking so only single detector layer.
– Can we measure >105 particles per pulse?
– Very high R&D cost compared to camera + screen.
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
9
MICE Sci-Fi Tracker
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
10
• Measure muons produced in MICE cooling channel.
• 5 scintillating fibre (SciFi) stations track individual particles.
• Each layer contains 3 sets of fibres at 120° giving redundant position.
• 350 m fibres on 427 m pitch with doublet layer gives 450 m resolution.
• Might provide a suitable alternative to drift chamber.
• Not clear it will handle multiple hits.
• Expensive…?
Future Plans
• Model beamline using GPT + GEANT4 to simulate unwanted particle flux reaching screen (Scott Mandry).
• Exhaustive search of available scintillators (Dan Hall):– Accelerators (survive higher current):
• Al2O3 (“ruby” powder, used in LHC BTV).• YAG:Ce (high light output).• Quartz (very rad hard, low light output).
– Detectors (high light output):• CdWO4/PbWO4/ZnWO4 (CMS ECal).• CsI(Tl) (very high light output, not rad hard).• BGO/LYSO (more rad hard for lower light).• Plastics (less rad hard, cheap).
– Plasma Wakefield (large area):• Lanex (large screens, vacuum safe?)• P43/P46/P47 phosphors (x-ray phosphors).
• Investigate feasibility of SciFi tracker for low particle flux.
19/10/12 Simon Jolly, UCL, AWAKE Collaboration Meeting
11
Spectrometer Camera• Camera already purchased.• Andor iStar 340T iCCD
camera:– 2048 x 512 total pixels
(1850 x 512 active with 25 mm intensifier).
– 13.5 um pixels.– Gen-2 W-AGT P43 intensifier,
gated at 7 ns.– Nikon F-mount lens mount.– 16-bit readout, 150 ke- pixel
full well.– http://www.andor.com/scientifi
c_cameras/istar_iccd_camera/340-intensified-sensor/
• Camera setup:– DAQ and control software.– Data analysis software to give
online measurement of witness beam energy spectrum.
– Mechanical design of camera support system for tests and installation in SPS tunnel (comes later).19/10/12 12Simon Jolly, UCL, AWAKE Collaboration
Meeting