electrical controls - auburn universitydbeale/mech4240-50/queen_au... · electrical controls ....
TRANSCRIPT
![Page 2: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/2.jpg)
• Contact blocks include normally open (NO), normally closed (NC), or both NO and NC contacts.
2
![Page 3: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/3.jpg)
• A joystick is used to control many different circuit operations from one location.
3
![Page 4: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/4.jpg)
• Limit switches are used to convert a mechanical motion into an electrical signal.
4
![Page 5: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/5.jpg)
• An actuator is the part of a limit switch that transfers the mechanical force of the moving part to the electrical contacts.
5
![Page 6: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/6.jpg)
• A foot switch is used to allow hands-free control or an additional control point.
6
![Page 7: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/7.jpg)
• Direct scan is a method of scanning in which the target is detected as it passes between the transmitter and receiver.
7
![Page 8: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/8.jpg)
• Retroreflective scan is a method of scanning in which the target is detected as it passes between the photoelectric sensor and reflector.
8
![Page 9: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/9.jpg)
• Diffuse scan is a method of scanning in which the target is detected when some of the emitted, reflected light is received.
9
![Page 10: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/10.jpg)
• Ultrasonic sensors detect objects by bouncing high-frequency sound waves off the object.
10
![Page 11: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/11.jpg)
• A reed relay is a fast-operating, single-pole, single-throw switch that is activated by a magnetic field.
11
![Page 12: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/12.jpg)
• Inductive proximity sensors use a magnetic field to detect the presence of a target.
12
![Page 13: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/13.jpg)
• Capacitive proximity sensors use a capacitive field to detect the presence of a target.
13
![Page 14: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/14.jpg)
• Capacitive sensors work based on the dielectric of the material to be sensed.
14
![Page 15: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/15.jpg)
• A Hall generator is a thin strip of semiconductor material through which a constant control current is passed.
15
![Page 16: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/16.jpg)
• Hall effect sensors are available in a variety of packages for different applications.
16
![Page 17: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/17.jpg)
• A line (ladder) diagram consists of a series of symbols interconnected by lines that are laid out like rungs on a ladder to indicate the flow of current through the various components of a circuit.
17
![Page 18: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/18.jpg)
• A solenoid is an electric output device that converts electrical energy into a linear mechanical force.
18
![Page 19: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/19.jpg)
• A contactor is a control device that uses a small control current to energize or de-energize the load connected to it.
19
![Page 20: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/20.jpg)
• The electrical operation of a contactor can be shown using a line diagram, a pictorial drawing, and/or a wiring diagram.
20
![Page 21: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/21.jpg)
• Auxiliary contacts may be added to a contactor to form an electrical holding circuit.
21
![Page 22: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/22.jpg)
• A magnetic motor starter is an electrically operated switch (contactor) that includes motor overload protection.
22
![Page 23: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/23.jpg)
• The electrical operation of a motor starter can be shown using a line diagram, a pictorial drawing, and/or a wiring diagram.
23
![Page 24: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/24.jpg)
• The three stages a motor goes through during normal operation include resting, starting, and operating under load.
![Page 25: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/25.jpg)
• An overload relay does not open a circuit while a motor is starting, but opens the circuit if the motor gets overloaded and the fuses do not blow.
![Page 26: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/26.jpg)
• In three-wire control, three wires lead from the control device to the starter or contactor.
![Page 27: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/27.jpg)
• A step-down control transformer is used to step down the voltage to the level required in the control circuit.
![Page 28: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/28.jpg)
• Contactors have either an AC coil or a DC coil, but may have either AC or DC contacts.
![Page 29: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/29.jpg)
• A magnetic motor starter is a contactor with overload protection added.
![Page 30: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/30.jpg)
• An electronic overload has built-in circuitry that senses changes in current and temperature.
![Page 31: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/31.jpg)
• Auxiliary contacts are added to give circuits with pushbuttons memory.
![Page 32: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/32.jpg)
• Two stop pushbuttons connected in series and two start pushbuttons connected in parallel are used to control a motor from two locations.
![Page 33: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/33.jpg)
• Two start/stop stations are used to control two separate magnetic motor starter coils with a common emergency stop protecting the entire system.
![Page 34: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/34.jpg)
• Two motors can be started almost simultaneously from one location to prevent product separation or stretching.
![Page 35: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/35.jpg)
• A pilot light is used with a pressure switch to indicate when a device is activated.
![Page 36: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/36.jpg)
• A pilot light is used with a start/stop station to indicate when a device is activated.
![Page 37: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/37.jpg)
• NOT logic is used to indicate when a device is not operating.
![Page 38: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/38.jpg)
• A sequence control circuit does not let the first conveyor operate unless the second conveyor has started and is running.
![Page 39: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/39.jpg)
• A selector switch is used to provide a common industrial jog/run circuit.
![Page 40: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/40.jpg)
40
![Page 41: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/41.jpg)
• A magnetic reversing starter may be controlled by forward and reverse pushbuttons.
41
![Page 42: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/42.jpg)
42
![Page 43: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/43.jpg)
43
![Page 44: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/44.jpg)
44
![Page 45: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/45.jpg)
45
![Page 46: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/46.jpg)
• A PLC simplifies the wiring of inputs and outputs by eliminating the need for auxiliary contacts on the starter.
46
![Page 47: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/47.jpg)
• Programmable logic relays are versatile and are normally used for control circuits that require numerous relays and/or frequent changes.
47
![Page 48: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/48.jpg)
48
![Page 49: Electrical Controls - Auburn Universitydbeale/MECH4240-50/Queen_AU... · Electrical Controls . Isaac Queen –iqueen@atn.org . . 1 ... of a limit switch that transfers the mechanical](https://reader034.vdocuments.us/reader034/viewer/2022042103/5e810712bd3b6c1fe130cfd0/html5/thumbnails/49.jpg)
49