ELECTRIC EARTHING AND SHOCK 

 

PRESENTED BY

P.RADHIKA

06C21A0241

TIRUMALA ENGINEERING COLLEGE

KEESARA

BOGARAM

Page 2: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 2/17

CONTENTS:

1. Introduction

2. Difference between neutral and earth wire

3. Why grounding is required

4. Methods of earthing

.Earthing through a water main

.Pipe earthing

.Plate earthing

5. Points to remember while providing earthing

.Distance

.Cross section of the earthing lead

.Crosse section of the earth continuity conductor

.Electrode

.Earth resistance

6. Conclusion

Page 3: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 3/17

INTRODUCTION:

 The meaning of the earthing or grounding is to connect the

electrical equipment to the general Mass of the earth by wire

of negligible resistance. This brings the body of electrical

equipment to Zero potential and thus will avoid the

shock to the operator. The neutral of the supply system

is Also solidly earthed to ensure its potential equal to

zero according to Indian Eale. [The earthed or connected

with earth means connected with the general mass of theearth In such manner as to sure at all times in immediate

discharge of energy without danger]

Difference between Neutral and Earth Wire:

1. The neutral wire is connected to the neutral point of thetransformer; which is earthed only at substation.The earth

wire originated from a solid earth at the substation and is

earthed at not less than four equally spaced points during

every 1.6km run of distribution line.

2. By reference to three phase four wire loads for which

student may consult any book dealing with poly phase

system it will be realized that the neutral wire carries the

return current in the case of single phase load and out of 

balance current in the case of unbalanced three phase

Page 4: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 4/17

loads.The earth wire under normal condition does not carry

any current.However,if an earth fault occurs the earth wire

will carry large current,which will cause,the fuse to blow out

thereby protecting life and equipment.

3. Some times when the neutral work is not available or

broken one is temted to connect a single phase load

between aphase wire and earth wire. Thise practice can be

dangerous because by dowing so the earth will assume

voltage above earth.

WHY GROUNDING IS REQUIRED?

 The metal cover of every electrical equipment is earthed to

get the protection against metric shock if the live wire

accidentally makes contact with metal frame to earth

through his body this is very dangerous to human life in

this.

However a metal frame is connected to earth through

an earth wire having low resistance path when live wire

touches the metal frame and a person also comes in contact

with metal frame, there will be parallel paths through which

the circuit will be completed one path is through human

body and other earth wire. The earthed wire will offer an

easier path as it is having low resistance. The resistance

Page 5: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 5/17

device against the electric shock to human being human will

be saved against fatal accident.

 

METHODS OF EARTHING

There are mainly three methods of earthling

1.EARTHING THROUGH WATER MAIN: Before making an

earthing connection to the water main,it must be

ascertained that throughout GALVANIZED IRON pipe have

been used other wise ,if the cement convegeate pipe have

been used the eathing damp should be used . the standard

copper lead is fanned out is soldered to make it sold .thenthe lead strip is bent round the pipe so that may be seated

properly over the pipe .the surface of the pipe is dened

proply and all trace & grater are removed and then over it is

Page 6: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 6/17

placed the clamp in between the clamp and pipe is inserted

the lead and is tighted with the screws

  2. pipe earthing:- If the water pipe cannot be used as

an earth the

GALVANIZED IRON pipe of approved length and diameter can

be used .the size of the pipe depends up on

A) The current to be carried.

B) The type of the soil.

 

Page 7: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 7/17

According to ISI std.NO.732-1963.the GALVANIZED IRON

pipe shall not be less than 38.1 mm. diameter & 2 m

.long for ordinary soil but if soil is dry and rocky, the

length of pipe should be increased to 2.75 m.

The pipe is placed up right as shown in fig

.and must be placed in a permanetly wet ground; the

depth at which the pipe should be buried depends upon

the condition of the ground moisture. According to I.S

the pipe should be placed at a depth of 4.75 m. it can be

less if the soil provide sufficient moister earlier. Pipe atthe bottom should be surrounded by broken pieces of 

coke or charcoal for a distance of about 15 cm around

the pipe. the coke increases the effective area of the

earth practically to side of the coke bed .impregnating

the coke with salt decreases the resistance generally

alternate system of layer of salt and coke are used for

best result as represented in fig. in India in summer

season the moisture in the soil will decreases to large

extent which will increase the earth resistance .so in

order to have effective earth resistance .whenever

needed ,3 to 4 bucket of water should be put into the

funnel connected to the main GALVANIZED IRON pipe

through 19 mm dia pipe.

 

 The earth lead used must be

GALVANIZED IRON wire or GALVANIZED IRON stripe (not

Page 8: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 8/17

of copper) of sufficient cross sectional area fault current

safely . (it should not be less then electrical equivalent

of copper conductor of 12.97 sq . mm (80 swg), cross-

sectional area .the wire from the GALVANIZED IRON pipe

of 19 mm dia . should be carried in a GALVANIZED IRON

pipe of dia 12.7 mm at a depth of about 60 cm . bellow

the ground .further when the wire is carried over from

mechanical injury by,caring the earth wire bin a recessed

portion.

Page 9: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 9/17

 

Page 10: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 10/17

3. PLATE EARTH ING: -  The earth connection can again

cable provided with the help of a copper plate or IRON  a

GALVANIZED. plate ,is used it should not be less then 00cm

x 60 cm x 6.36 m while for copper plate these dimension

may be 60 cm x 60 cm x 3.18mm . how ever the used of the

copper plate these days is limited.

The plate is kept with its phase vertical at a

depth of 3m.(10ft)and is so arranged that it is embedded in

Page 11: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 11/17

a alternate layer of cock and salt for a minimum thickness of 

about 15cm.In case earthing is done by copper plate and in

cock layer of 15cm. if it done GALVANIZED IRON plate. The

earth wire is securely bolted of which are shown in fig. It

should be remembered that the nuts and bolts must be of 

copper for copper plate and should be of GALVANIZED

IRON.For galvanized plate the other details of plate earthing

Page 12: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 12/17

are same as that of GALVANIZED IRON.pipe earthing.

Page 13: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 13/17

Points to remember while providing earthing:

1) Distance :-

 The distance of the electrode from the installation at thepremises should be more than 1.5 meter.

2) Cross - Section of the earthing lead :-

Page 14: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 14/17

It should never be less than half the cross - section of the

mains wire or conductor. The selection should be made in

such a way that even in worst condition it shall not fuse out.

 The minimum size of the earthing lead should not be less

than electrical equivalent of copper conductor of 8 SWG

(12.97 sq.mm x -section). The size of earthing lead for

various loads and installation are given below.

3) Cross section of earth continuity conductor :-

 The size of the earth continuity conductor should not be lessthan

14 SWG (2.894 Sq.mm.)

4) Electrode :-

As already discussed, the earthing can be done either with

plat or pipe electrode. It should be remember that the

material for earth electrode & earth lead should be same

and the electrode should always be placed in vertical portion

5) Earth resistance :-

 The earth resistance of any earthing should not be more

than 5 cms. As already soil that for better performance at

power hour and Sub-Station or for high horse power motor

beyond 100 H.P. The earth resistance should be up to 0.5

cm. & 1 cm. respectively. The resistance of earth dependent

upon area of electrode in contact

Page 15: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 15/17

with the general mass of earth. The quantity of earth, chock

& salt. The resistance of an existing earth can be increased

by purring water for G.I. plate earthing salted water for

copper plate earthing. The low resistance can be obtained by

increasing the X-section area of electrode.

Page 16: Electric Earthing and Shock

8/2/2019 Electric Earthing and Shock

http://slidepdf.com/reader/full/electric-earthing-and-shock 16/17

Conclusion: