    EI-MINI

    SIZE 1 SIZE 2

    Specification

    Model

    SP2 SP4 SP7 LP2 LP4 LP7 GP4 GP7 G1P5 FP7 F1P5

    Power rating UP to KW(HP)

    0.2(1/4)

    0.4(1/2)

    0.7(1)

    0.2(1/4)

    0.4(1/2)

    0.7(1)

    0.4(1/2)

    0.7(1)

    1.5(2)

    0.7 (1) 1.5 (2)

    AC Input Voltage 1 100-120 (VAC) 1 200-240 (VAC) 3 200-240 (VAC) 3 380-440(VAC)

    AC Input Frequency 45~60 Hz

    AC Output Voltage 0 to 220V 3 Output 0 to Input Voltage, Three-Phase Output

    AC Output Frequency 0 to 50/60Hz or 0 to 100/120Hz

    AC Output Current(100%)

    1.5A 2.4A 4A 1.5A 2.4A 4A 2.4A 4A 7A 2.4A 4A

    Overload Capacity(150% for 60 seconds)

    2.2A 3.6A 6A 2.2A 3.6A 6A 3.6A 6A 10.5A 3.6A 6A

    PWM Switching Freq. 16KHz

    Storage Temperature -40C to + 65C (-40F to 149F )

    Operating Temperature 0C to + 50C (32F to 122F )

    Operating Modes Speed Mode, 2-Wire and 3-Wire Modes

    Stop Modes Ramp Stop, or DC Injection

    Load Constant Torque or Fan (Variable Torque)

  • 7/27/2019 El Mini Series

    6/11

    S e t - u p a n d O p e r a t i o n

    Power Connections

    Connect the fused/protected 220 volt 50/60Hz supply to the power terminal 'R' and 'T'.

    Polarity is not important. Ensure the supply is adequately fused/protected depending onthe latest codes of practice for electrical installation.

    Connect the 220 volt 3 phase motor to the power terminal 'U', 'V' and 'W'. Polaritydetermines direction.

    Remark: Rage G & F Models are all Three-phase input basic on (R.S.T) design.

  • 7/27/2019 El Mini Series

    7/11

    Control Connections

  • 7/27/2019 El Mini Series

    8/11

    The control inputs

    Terminal V1 0 volt or control common (connected to -DC of power circuit) (isolated)

    Terminal V2 Speed reference input from 0 to 5 volt or 0 to 10 volt or 4-20mA, select byjumper J3

    Terminal V3 +5 volt output for the 5k Speed potentiometer

    Terminal FOR Forward run when CLOSED; stopped when OPEN

    Terminal REV Reverse run when CLOSED; stopped when OPEN

    Terminal RESET Fault Reset when CLOSED

    Terminal STOP In 3-WIRE mode, when CLOSED then allow to run

    Terminal FM Analog output signal for Frequency output

    Terminal V0 Control Common

    Terminal TRIP Fault output (open collector output)

    Terminal FUNC Multi-function output (Drive running or Drive speed agree, select by switchS1)

    Terminal COM TRIP, FUNC fuction common

    Terminals Switch S3 Action 0V connected Disconnect from 0V

    Run Forward Stop

    Run Reverse Stop

    Allow to Run Disable output

    FORREVSTOPRESET

    2-wire modeswitch S3 ON

    Reset No action

    Run Forward No actionRun Reverse No action

    Allow to Run Disable output

    FORREVSTOPRESET

    3-wire modeswitch S3 OFF

    Stop and Reset No action

    Speed reference select: jumper J3

    0V-10V

    0V-5V

    0-20mA

  • 7/27/2019 El Mini Series

    9/11

    C o n t r o l P r e s e t

    P o t e n t i o m e t e r s

    The 5 pre-set potentiometers adjust the following parameters

    UL Sets the maximum speed available and has a range from 0Hz (fully counterclockwise) to Base Speed (or X2) (fully clockwise) depending on switch S7 and S8.

    LL Sets the minimum speed available and has a range from 0Hz (fullycounterclockwise) to Base Speed (or X2) (fully clockwise) depending on switch S7and S8.

    ACC Sets the acceleration time from 0.5 sec (fully counter clockwise) to 130 sec (fullyclockwise) to attain 0Hz from Base Speed (or X2) from 0Hz depending on switchS7 and S8.

    DEC Sets the deceleration time from 0.5 sec (fully counter clockwise) to 130 sec (fullyclockwise) to attain 0Hz from Base Speed (or X2) from 0Hz depending on switchS7 and S8.

    THRY Sets the 40-100% current value for the 'lxt' calculation. (7-seg display will show 5

    when measured motor current is greater than 100% of the value set by THRY, andthus 'lxt' is intergrating up.) Fully counter clockwise equals zero current for 'lxt'setting and fully clockwise equals 2.3A (0.5HP/220VAC) or 1.4A (0.25HP/110VAC)current for 'lxt' setting.

    The setting range ofUL and LL provide for full rotation of the external Speed Potentiometerto operate over a band width of 1Hz or more over any part of the speed range, to BaseSpeed X2. Setting LL greater than UL causes the minimum speed to equal the maximumspeed set by UL.