ejc catalog
TRANSCRIPT
C/S Expansion Joints @ The Cathedral of Christ the Light
07 95 00/CON
BuyLine 1803
Pasadena City Hall was built in 1927 to inspire a city with beauty, boldness and
vision. It is an important part of this community’s rich architectural heritage. It is one
of the finest examples of the California Mediterranean style. Designed by Bakewell
and Brown in San Francisco, the 80 year old Pasadena City Hall is one of the mostdistinctive public buildings in the United States and is listed on the
National Register of Historic Places. One of the primary reasons for the seismic
retrofit of Pasadena City Hall was that studies in the 1990s indicated that major
earthquakes in the future could destroy several parts of the building completely
and result in loss of life. In 2003, the City Council approved a plan for the seismicretrofit and historic restoration. Seismic retrofit of the building included the
installation of structural base isolators that now allow the
building to withstand future earthquake activity. Restoration
activities were undertaken to preserve many of the historic
architectural elements of City Hall.
An 80 year old architectural icon gets a seismic makeover.
P A S A D E N A C I T Y H A L L C/S Expansion Joint Coverson the job
Pasadena City Hall achieves LEED® Gold status
Along with the seismic upgrade, the City ofPasadena requested that the building be LEED®Certified. The design team used sustainable strategies throughout the project. Even the C/Sexpansion joint covers in the patio area are hidden beneath a 4" layer of decomposed granite.
Architect: Architectural Resources Group (ARG) San Francisco, CAConstruction Manager: DM-JMH+NContractor: Clark Construction Group
C/S Stone Paver Seismic Covers allowthe Pasadena City Hall to move 30"
For the seismic upgrade of the Pasadena CityHall ARG architects specified 33" SSRW SeismicStone Paver Floor Covers to fill the moat areasurrounding the building’s perimeter in itsinner courtyard. The covers provide full fourway movement and are designed to work inconjunction with the base isolators when aseismic event occurs.
No matter how much movement your project requires, we can hide it.C / S E X P A N S I O N J O I N T C O V E R S
C/S @ Orange County Performing Arts CenterIn the interior of the magnificent Segerstrom Concert Hall,Architect Pelli Clarke Pelli specified C/S 12" LAF Seismic WallCovers. Virtually imperceptible the LAF wall covers are lightweight, match the concert hall’s wall finish without visual interruption and provide full movement of the joint without damage to surrounding wall surfaces.
54
C/S @ de Young MuseumA major consideration of the de Young project was that theexpansion joint covers must be “virtually invisible” within the museum’s weathered copper skin. Architects Fong & Chan,SF; and Herzog & de Meuron specified CS’ XLS cover system knowing it could be seamlessly incorporated into the facade’scopper panel frame. The 24" XLS covers are designed to release from the wall to provide full seismic movement.
Solving complex building movement problems for 40 yearsC / S E X P A N S I O N J O I N T C O V E R S
C/S supplied unobtrusive SM-2 Wall Covers to match blend surrounding wall surfacesand to provide multi-directional thermalmovement in order to keep the facility walls from cracking.
Throughout San Francisco InternationalAirport’s base isolated main terminal,massive C/S wall floor and ceiling coversprovide four way movement up to 60"while being virtually invisible. The SSRStone Paver floor joints are 200' long and provide 36" of movement.
San Francisco International AirportArchitect: Skidmore, Owings & Merrill
NewseumArchitect: Polshek Partnership
A seismic upgrade was required for thislandmark building. Parsons specified C/SGyrometric cabs (Model MACC) and SSRWSeismic moat covers to provide egressfrom the building during seismic activity.
Utah State Capitol BuildingProject Manager: Parsons Corporation
Center for the Intrepid Armed Forces PhysicalRehabilitation CenterArchitect: The Smith Group
To provide movement and securitybetween the Newseum and the adjacentCanadian Embassy, Polshek Partnershipspecified SC-1200 Exterior Covers andSRJ-1200 Roof Covers that tie both buildings together. The covers with factory mitered transitions are attached to the building’s delicate marble surface.
9
Drywall, ceramic tile
Drywall, ceramic tile
Drywall, panel systems, metalcladding, stone
All finishes All finishes All roof finishes Concrete, paver
Minimum exposedsurface, sealed gasket installation
Minimum exposedsurface, sealed gasket installation,larger movement
Minimum exposedsurface, optionalsealed gasketinstallation, seismicmovement
Robust applications, lowmaintenance, full movement range
Minimum exposedsurface, sealed gasket installation, full movement range
Formed aluminumand EPDM bellowsoptions, full movement range
Exterior, waterproof applications, full movement range
Flush Thinline Gasketed
Flush Twinline Dual Gasketed
Seismic FlushTwinline
Allway Metal Exterior Wall Roof Parking &Stadiums
1" to 4" 2" and up 4" and up 1" to 4" 2" and up 2" and up 1" to 16"
Hygienic, matches Thinlinefloor covers
24-25
8-9
N/A
ReflexPage 39
Hygienic, matches Twinlinefloor covers
26-27
10-11
N/A
MultiflexPage 39
All commercial andhealthcare interiorsand exteriors
26-27
12-15
N/A
Multiflex or FB-97Page 39
Industrial, matchesAllway floor covers
28-29
16-17
N/A
Reflex or Multiflex Page 39
All exteriors,colorable
30-33
N/A
N/A
ContactFactory
All roofs
34-35
N/A
N/A
ContactFactory
Vehicular traffic, stadium seatingbowls and concourse
36-37
N/A
N/A
ContactFactory
25-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
25-100% Of Joint Width
By assigning our metal systems a cost of 100, you can determine how much an alternate system of similar size will cost.
This catalog is designed to convey the design concept and variations available with C/S joint cover systems–for more accurate details go to: www.c-sgroup.com
55 180 N/A 100 150 N/A N/A
1008
Selection Chart
The size of joint and movement dynamics dictate whether you
require a standard or seismic expansion joint cover system. Before
making a selection, there are other decisions you must make. The
selection of the floor cover is often the most critical step in the
specification process since the performance of the floor cover has the
greatest impact on the occupants of the building. The presence of rolling
loads and the need for hygiene are major considerations in cover
selection, while aesthetics in seismic covers is also a significant issue.
Joint Size
Appearance
Cover Type
Description
Finishes
Designed For
% Movement +/-
Page #
Matching Floor
Wall/Ceiling
Fire Barriers
Cost Index
Minimum exposedsurface, sealed gasket installation
Carpet, vinyl,ceramic tile, terrazzo, stone
Hygienic, wheeled equipment
10-11
N/A
24-25
ReflexPage 39
Carpet, vinyl Carpet, vinyl, terrazzo, stone
Concrete, carpet,vinyl
Concrete, pavers,carpet, vinyl,ceramic tile
Carpet, vinyl
Minimum exposedsurface, sealed gasket installation,larger movement
Minimum exposedsurface, optionalsealed gasketinstallation, seismicmovement
Robust applications, low maintenance
Robust applications, low maintenance,seismic movement
Corridors in base isolated structures withmulti-directionalmovement
1" and 2"
Flush ThinlineGasketed
Flush TwinlineDual Gasketed
Flush Seismic,Seismic Pan
Standard Allway Metal
Seismic Allway Metal
SeismicCorridor Cover
2" to 4" 4" and up 1" to 4" 4" and up 4" to 36"
65
Hygienic, wheeled equipment
12-13
N/A
24-25
MultiflexPage 39
Hygienic, wheeled equipment, deepfloor finish materials,also exterior
14-17
N/A
26-27
Multiflex or FB-97Page 39
Industrial, heavy wheeledequipment
18-19
N/A
28-29
ReflexPage 39
Industrial, heavy wheeled equipment, alsoexterior
20-21
N/A
26-27
MultiflexPage 39
Commercial and healthcareinteriors
22-23
N/A
22-23
FB-97Page 39
50-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
50-100% Of Joint Width
50% Of Joint Width25% Of Joint Width
All C/S Expansion Joint Covers, Seals and Processes are ISO 9001: 2000 compliant.
Floor Covers
105 125 100 100 N/A
Specialty covers, such as roof covers
and vehicular joint systems, are
available for most joint sizes and
movement dynamics.
Having selected the floor cover, identifying a matching wall cover is a relatively simple task.
When it comes to seismic covers, however, there are options driven by both functionality and
aesthetics. Choose from covers that become detached from the wall to minimize damage or
ones that are self-closing to minimize post-event maintenance. Many of our wall covers are
designed to accept a range of surface materials to maximize concealment of the cover.
Wall & Ceiling Covers Specialty Covers
1110
FLUSH
Thinline Floor COVERS 1"-2"
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Miami International Airport, FL
Model Data Floor to Wall Covers
Model Data Floor to Floor Covers
1" 2" 1" 2" 1" 2" 1" 2"
MINIMUM OPENING 0.75" 1.5" 0.75" 1.5" 0.75" 1.5" 0.75" 1.5"
MAXIMUM OPENING 1.25" 2.5" 1.25" 2.5" 1.25" 2.5" 1.25" 2.5"
EXPOSED SURFACE 1.12" 1.88" 1.18" 1.88" 2.63" 3.56" 2.63" 3.56"
SPECIFY MODEL GFTW 100 GFTW 200 GFPSW 100 GFPSW 200 GFSW 100 GFSW 200 GFSTW 100 GFSTW 200
1" 2" 1" 2" 1" 2" 1" 2"
MINIMUM OPENING 0.75" 1.5" 0.75" 1.5" 0.75" 1.5" 0.75" 1.5"
MAXIMUM OPENING 1.25" 2.5" 1.25" 2.5" 1.25" 2.5" 1.25" 2.5"
EXPOSED SURFACE 1.25" 1.88" 1.18" 1.88" 4.31" 5.13" 4.31" 5.06"
SPECIFY MODEL GFT 100 GFT 200 GFPS 100 GFPS 200 GFS 100 GFS 200 GFST 100 GFST 200
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
Use this cover for:
• Applications with small, interior joints where minimal visual impact is preferred.
• Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish.
• Where wheeled equipment is to be used.
• Where hygiene is important.
How it works:
Single gasket expands and compresses during movement. 2" model includes aluminum support plate for added durability.
Gasket Colors
Black White Gray Greige
Note: Custom colors available. Call 800-233-8493.
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Non-ShrinkGrout
Gasket
Floor to Wall Covers Floor Covers
GFTW-100GFT-100
Floor Covers
GFT-200
GFPS-100 GFST-200
Floor Finish
W
Carpet
WContinuous ExtrudedAluminum Frame
W
W
Non-ShrinkGrout
Continuous ExtrudedAluminum Frame
ContinuousExtrudedCentralPlate
FloorFinish
Continuous ExtrudedAluminum Wall Frame
W Continuous ExtrudedAluminum Frame
GFTW-200 GFPS-200 GFS-200W
Carpet
W
Continuous ExtrudedAluminum Wall Frame
W
1"-3"
1"-3 "
1"-3"
1"-3"
Gasket
ES
ES
ES
ES
ES
ES
ES
ES
Model Data Floor to Wall Covers
JOINT WIDTH 2" 3" 4" 2" 3" 4" 2" 3" 4"
MINIMUM OPENING 1.0" 1.5" 2.0" 1" 1.5" 2" 1.0" 1.5" 2.0"
MAXIMUM OPENING 3.0" 4.5" 6.0" 3" 4.5" 6" 3.0" 4.5" 6.0"
EXPOSED SURFACE 6.5" 10.0" 11.0" 6.5" 10" 11" 6.5" 10.0" 11.0"
SPECIFY MODEL GTR 200 GTR 300 GTR 400 GTR-HD 200 GTR-HD 300 GTR-HD 400 GTP 200 GTP 300 GTP 400
Model Data Floor to Floor Covers
12 13For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Inova Fairfax Hospital, VA
FLUSH
Twinline Floor COVERS 2"-4"
Black White Gray Greige
Note: Custom colors available. Call 800-233-8493.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH 2" 3" 4" 2" 3" 4" 2" 3" 4"
MINIMUM OPENING 1.5" 2.25" 3.0" 1.5" 2.25" 3.0" 1.5" 2.25" 3.0"
MAXIMUM OPENING 2.5" 3.75" 5.0" 2.5" 3.75" 5.0" 2.5" 3.75" 5.0"
EXPOSED SURFACE 4.25" 6.5" 7.5" 4.31" 6.56" 7.56" 4.25" 6.5" 7.5"
SPECIFY MODEL GTRW 200 GTRW 300 GTRW 400 GTPW-HD 200 GTPW-HD 300 GTPW-HD 400 GTPW 200 GTPW 300 GTPW 400
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
Use this cover for:
• Applications with larger thermal movement requirements and where a flush, concealed cover is preferred.
• Applications using carpet or vinyl floor covering up to 1/8" deep.
• 3/8” Recessed center plate available.
• Where wheeled equipment is expected.
• Where hygiene is important.
How it works:
Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening.
Floor to Wall Covers Floor CoverHeavy Duty 2,000 lb. Point Load
GTPW-HD(Heavy Duty)
GTRWGTR
GTPW
GTR-HD(Heavy Duty)
GTP
Floor Covers
Gasket Colors
ES
Continuous ExtrudedAluminum Frame
GasketContinuous ExtrudedAluminum RecessedCenter Plate 1/4" Aluminum
Center Plate
ES
Heavy Duty Frame
Floor FinishMatching(By Others)
ES
ES
GasketContinuous ExtrudedAluminum Flush Center Plate
5/8"
5/8" 5/8"
Floor Finish(By Others)
Continuous ExtrudedAluminum Frame
ES
5/8"
ES
3/4"
3/4"
W W W
W W W
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
14 15
JOINT WIDTH 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"
MINIMUM OPENING 2.5" 2.5" 2.5" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0"
MAXIMUM OPENING 8.0" 9.0" 11.0" 12.0" 14.0" 15.0" 17.0" 18.0" 20.0" 21.0" 23.0" 24.0"
EXPOSED SURFACE 12.0" 13.0" 15.0" 16.0" 18.0" 19.0" 21.0" 22.0" 24.0" 25.0" 27.0" 28.0"
SPECIFY MODEL SGR 500 SGR 600 SGR 700 SGR 800 SGR 900 SGR 1000 SGR 1100 SGR 1200 SGR 1300 SGR 1400 SGR 1500 SGR 1600
Model Data Floor to Floor Covers
JOINT WIDTH 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"
MINIMUM OPENING 4.0" 4.5" 5.25" 5.5" 5.75" 6.25" 6.75" 7.25" 7.75" 8.25" 8.75" 9.25"
MAXIMUM OPENING 7.0" 8.0" 9.5" 10.5" 12.0" 13.0" 14.5" 15.5" 17.0" 18.0" 19.5" 20.5"
EXPOSED SURFACE 8.5" 9.5" 11.0" 12.0" 13.5" 14.5" 16.0" 17.0" 18.5" 19.5" 21.0" 22.0"
SPECIFY MODEL SGRW 500 SGRW 600 SGRW 700 SGRW 800 SGRW 900 SGRW 1000 SGRW 1100 SGRW 1200 SGRW 1300 SGRW 1400 SGRW 1500 SGRW 1600
Model Data Floor to Wall Covers
Floor Covers Floor to Wall Covers
Gaskets Disengage to AllowFull Seismic Movement
“Turnbar” Rotates and Keeps Plate Centered During Movement Cycle
Hinged Side Frame
Hinged Side Frame
SGPW
SGR*SGR Contracted
SGP*
SGRW
SGR Expanded
Cycling
Gasket Colors
Plate Deflectors Ensure System RemainsOperable through Major Seismic Activity
W
W
W
W
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
40 Bank Street, London SGR and SGP have same model data. SGRW and SGPW have same model data. For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
FLUSH
Seismic Floor COVERS 5"-UP
Black White Gray Greige
3/4"
3/4"
3/4"
3/4"
Use this cover for:
• Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes.
• Applications using carpet or vinyl floor covering up to 1/8" deep.
• Where wheeled equipment is expected.
• Where hygiene is important.
How it works:
Dual gaskets expand and contract during minor thermal movement. During full seismic activity, gaskets disengage and the aluminum center plate that spans the joint opening temporarily displaces.
*Can be modified to provide up to 100% movement
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
ES
ES
ES
ES
Note: Custom colors available. Call 800-233-8493.
Model Data Floor to Wall Covers
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.0" 2.5" 3.0" 4.0" 4.0" 4.0" 4.0" 4.0"
MAXIMUM OPENING 3.0" 9.0" 11.0" 12.5" 15.5" 18.5" 21.5" 24.5"
EXPOSED SURFACE 10.88" 12.88" 14.88" 18.6" 20.5" 23.75" 26.75" 32.75"
SPECIFY MODEL SSR 200 SSR 400 SSR 600 SSR 800 SSR 1000 SSR 1200 SSR 1400 SSR 1600
Model Data Floor to Floor Covers
1716
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.0" 1.5" 2.0" 4.0" 4.0" 4.0" 4.0" 4.0"
MAXIMUM OPENING 3.0" 6.5" 8.5" 10.25" 12.75" 15.25" 17.75" 20.25"
EXPOSED SURFACE 6.44" 8.44" 10.44" 14.38" 16.88" 19.38" 21.88" 24.32"
SPECIFY MODEL SSRW 200 SSRW 400 SSRW 600 SSRW 800 SSRW 1000 SSRW 1200 SSRW 1400 SSRW 1600
SSR Contracted
Cycling
SSR Expanded
Floor Covers Floor to Wall Covers
SSRW-800
SSR-200-600
SSR-800
SSRW-400ContinuousAluminum Frame
ES
ExtrudedAluminumCenter Pan
2-1/4"
InfillMaterial
Continuous Aluminum Pan Nosing
SealantandBacker
Aluminum Hinge
2-1/4"
2-1/4" 2-1/4"
Center Pan Lifts Clear Of Moving StructureBut Remains Centered Over Opening
Unique Gravity Activated Turnbar System ReturnsCover To Normal Position After Event
Can be used As “Moat Cover” For Base Isolated Structures
Modular Pan ConstructionFor High Strength
Unit Sealed WithStandard Caulking
W
W W
ES ES
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
San Francisco International Airport, CA
W
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
PAN
Seismic Floor COVERS 4"-UP
Use this cover for:
• Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes.
• Applications with floor finishes of up to 1-1/2" thick.
• Heavy duty versions available for limited vehicular access.
How it works:
Sealant and Backer Rod expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
ES
Model Data Floor to Wall Covers
18 19
JOINT WIDTH 2" 4" 2" 4" 2" 4" 2" 4" 2" 4"
MINIMUM OPENING 1.0" 2.5" 1.0" 2.5" 1.0" 2.0" 0.0" 0.0" 1.0" 2.5"
MAXIMUM OPENING 3.0" 5.5" 3.0" 5.5" 3.0" 5.5" 3.5" 6.5" 3.0" 5.5"
EXPOSED SURFACE 2.82" 5.18" 4.87" 7.87" 6.75" 8.25" 3.75" 6.75" .081" 1.25"
SPECIFY MODEL ALRW 200 ALRW 400 ALSW 200 ALSW 400 ALW 200/HD ALW 400/HD PCW 200 PCW 400 FYWW 200 FYWW 400
Floor to Wall Covers
ALRW
ALSW
PCW
W
Continuous Extruded AluminumPlate For Carpet/Vinyl
Continuous Extruded AluminumFloor To Wall Frame
W
ES
Continuous Extruded Aluminum Serrated Plate
Continuous Extruded AluminumFloor To Wall Frame
W
ES
ES
Continuous Extruded AluminumFloor To Wall Cover Plate
1"
1"
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Chek Lap Kok Airport, Hong Kong
Model Data Floor to Floor Covers
JOINT WIDTH 1" 2" 4" 2" 4" 2" 4" 2" 4" 2" 4" 2" 4"
MINIMUM OPENING .7" 1.5" 3.1" 0.0" 1.0" 0.0" 1.0" 0" 1.0" 0.0" 0.0" 1.0" 2.5"
MAXIMUM OPENING 1.2" 2.5" 4.7" 4.0" 7.0" 4.0" 7.0" 4.0" 7.0" 3.5" 6.5" 3.0" 5.5"
EXPOSED SURFACE 1.7" 3.25" 5.25" 3.65" 6.43" 7.75" 11.75" 9.00" 12.50" 5.25" 8.25" .081" 1.25"
SPECIFY MODEL APF 25 APF 50 APF 100 ALR 200 ALR 400 ALS 200 ALS 400 AL 200/HD AL 400/HD PC 200 PC 400 FYW 200 FYW 400
STANDARD ALLWAY
Metal Floor COVERS 1"-4"
APFW
Continuous Extruded Aluminum Center Plate Insert
Continuous ExtrudedAluminum Cover Plate
ES
AL-HD
FYW
Specify Heavy Duty Model AL-HD For 2000 lb. Rolling Loads
W
Continuous Extruded Aluminum Frame
Continuous Extruded AluminumSerrated Cover Plate
1"
ES
W
1/4” & 1/8” Carpet
1"
ES
Extruded Aluminum Frame
Gasket Colors
ALR
Floor Covers
ALS
PC
Recessed Cover PlateContinuous ExtrudedAluminum Center Plate
W
W
ES
1/8” Floor Finish (ByOthers)
Continuous ExtrudedAluminum Frame
Serrated Side Plates Create A More Flush Surface,But Impact Visibility
Continuous ExtrudedAluminum Center Plate
Extruded AluminumFrame
1"
1"
W
Continuous ExtrudedAluminum Cover Plate
ES
Floor Covers
Note: All joint systems on this page are available for 1"-4" joints. Contact factory if required size is not listed.
Use this cover for:
• Use APF Series for applications with heavy rolling loads.
• Interior applications where low maintenance is desirable or for tamperproof applications.
• Suitable for most floor finishes – frame configuration variable to suit selected finish.
How it works:
Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
ES
20 21
JOINT WIDTH 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 2.0" 3.0" 3.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"
MAXIMUM OPENING 6.0" 9.0" 13.0" 3.5" 6.5" 9.75" 4.38" 7.0" 11.5" 13.5" 17.0" 20.0" 23.0" 25.5"
EXPOSED SURFACE 8.75" 11.75" 14.75" 5.5" 8.5" 11.5" 3.5" 7.5" 11.88" 15.0" 17.88" 21.0" 23.88" 27.0"
SPECIFY MODEL SJ-HD400 SJ-HD600 SJ-HD800 SJPF 200 SJPF 400 SJPF 600 SJP 200 SJP 400 SJP 600 SJP 800 SJP 1000 SJP 1200 SJP 1400 SJP 1600
Model Data Floor to Floor Covers
SJPF*
Floor Covers
SJHD*Heavy Duty 2,000 lb. Point Load
Floor to Wall Covers Floor Covers
SJP*
SJPFW*
SJWHD*Heavy Duty 2,000 lb. Point Load
SJPFB/SS*W
Continuous ExtrudedAluminum Side Frame
Continuous ExtrudedAluminum Frame
AluminumCenter Plate
Non-ShrinkGrout
FloorFinish
W
ES
ES
W
Bronze or Stainless Center Plate
ES
W
Continuous ExtrudedAluminum HD Frame
Continuous ExtrudedAluminum Frame
ES
Heavy Duty Frame
W
FormedAluminumCenter Plate ES
Aluminum Center Plate May be Bronze or Stainless Steel
W
1-1/8" 1-1/8"
1-3/8" 1-1/2"
TurnbarAssembly
ES
1-1/8"
1-3/8"
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Banner Gateway Medical Center, AZ
JOINT WIDTH 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 3.0" 4.25" 5.0" 1.0" 1.0" 1.0" 0.5" 2.25" 3.25" 4.38" 5.38" 6.38" 7.38" 8.38"
MAXIMUM OPENING 5.0" 7.5" 10.5" 3.0" 5.25" 7.88" 3.13" 5.5" 8.5" 11.0" 13.5" 16.0" 18.5" 21.0"
EXPOSED SURFACE 6.38" 8.88" 12.38" 3.75" 6.25" 8.75" 3.24" 5.75" 9.0" 11.5" 14.0" 16.5" 19.0" 21.5"
SPECIFY MODEL SJW-HD400 SJW-HD600 SJW-HD800 SJPFW 200 SJPFW 400 SJPFW 600 SJPW 200 SJPW 400 SJPW 600 SJPW 800 SJPW 1000 SJPW 1200 SJPW 1400 SJPW 1600
Model Data Floor to Wall Covers
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
SEISMIC ALLWAY
Metal Floor COVERS 4"-UP
Use this cover for:
• Interior or exterior seismic applications where aesthetics are not a primary concern.
• Limited vehicular access (heavy duty models).
How it works:
Self centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slidesover floor surface during seismic movement.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
Turnbar
*Can be modified to provide up to 100% movement.
22 23
How the Gyrometric Cover Works
Full Closed (During Compression) During an event in the contraction or compression mode the cab slides fully into the adjoining structure.
Lateral Shear The cab is attached to the fixed structure by means of a friction-freesliding track assembly to allow full lateral shear between buildings.
Full Open (During Tension) During an event in the expansionor tension mode the cab slides fully out.
SEISMIC
Corridor CoversFOR BASE ISOLATED STRUCTURES
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
de Young Museum, CA
Floor/Wall Section
Typical Floor Section
Cover Details
Unique Honeycomb StructureSupports Plate ThroughoutMovement Cycle
Also Available As AConventional LinealCover, Model XYZ
Center Pan Locked Into And GuidedBy Track At Base Of Side Walls
This system allows full access between base isolated and
fixed structures. It is perfect for where egress is necessary
during an earthquake. Because base isolated structures are
free to move in any horizontal direction, they create
distinct challenges for the design of the seismic joint covers.
The C/S solution for base isolated structures is an integrated
assembly approach with floor, wall and ceiling covers connected
and moving in unison. This Gyrometric System, or “cab
assembly,” provides full movement of up to 100% in
any horizontal direction. The floor cover may be used
independently of the wall and ceiling covers for lineal
applications where lateral shear is a problem
(specify model XYZ).
•OSHPD approved designs
• Complies with ASTM E1399
• Complimentary pre-construction design assistance
• Fire rating available; compliant with UL 2079
• Wide range of custom finishes available
• Virtually any joint size/movement capability can be accommodated
24 25
Gasket Colors
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Ontario Convention Center, CA
Model Data Wall to Wall Covers
Model Data Corner Wall Covers
JOINT WIDTH 1" 2" 3" 4" 2" 3" 4" 1" 2" 3" 4" 2" 3" 4"
MINIMUM OPENING 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"
MAXIMUM OPENING 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0" 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0"
EXPOSED SURFACE 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0"
SPECIFY MODEL FWF 100 FWF 200 FWF 300 FWF 400 FWS 200 FWS 300 FWS 400 FCF 100 FCF 200 FCF 300 FCF 400 FCS 200 FCS 300 FCS 400
JOINT WIDTH 1" 2" 3" 4" 2" 3" 4" 1" 2" 3" 4" 2" 3" 4"
MINIMUM OPENING 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"
MAXIMUM OPENING 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0" 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0"
EXPOSED SURFACE 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0"
SPECIFY MODEL FWFC 100 FWFC 200 FWFC 300 FWFC 400 FWSC 200 FWSC 300 FWSC 400 FCFC 100 FCFC 200 FCFC 300 FCFC 400 FCSC 200 FCSC 300 FCSC 400
Model Data Corner Ceiling Covers
Model Data Ceiling Covers
Black White Gray Greige
Note: Custom colors available. Call 800-233-8493.
Use this cover for:
• Wall and ceiling applications to align with and match flush Thinline covers used in the floor.
• Suitable for most wall and ceiling finishes – frame configuration variable to suit selected finish.
• Where hygiene is important.
How it works:
Multi-directional flush single gasket wall and ceiling coveraccommodates both thermal and seismic movement.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
FLUSH
Thinline Wall & CEILING COVERS 1"-10"
FWFC
Continuous ExtrudedAluminum Frame
FeatheredJoint Cement
W
ES
Wall Covers
Corner Wall Covers
Ceiling Covers Corner Ceiling Covers
FWFC-MFWF
Wall Covers
FWS
FCF FCFC
FCS FCSC
ContinuousAluminum Frame
Continuous ExtrudedAluminum Frame
Feathered Joint Cement
Ribbed Gasket OffersBetter Movement
Gasket SuspendedCeilingW
ContinuousAluminum Frame
Feathered Joint Cement
W
WW
W
Continuous ExtrudedAluminum Frame
W
SuspendedCeiling
SuspendedCeiling
ContinuousAluminumFrame
SuspendedCeiling
W
ES ES ES
ES
ES ESES
26 27For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
FLUSH
Twinline Wall & CEILING COVERS 2"-UP
Use this cover for:
• Wall and ceiling applications to match flush Twinline covers used in the floor.
• Suitable for most wall and ceiling finishes.
How it works:
Dual gaskets expand and compress during movement, durable aluminum center plate can be painted to match wall finish and temporarily displaces during seismic events.
Model Data Wall Covers
Model Data Corner Wall Covers
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.0" 2.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"
MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 8.0" 12.0" 16.0" 20.0" 24.0" 28.0" 32.0"
EXPOSED SURFACE 6.5" 11.0" 13.0" 16.0" 19.0" 22.0" 25.0" 28.0" 11.13" 13.13" 15.13" 17.13" 19.13" 21.13" 23.13"
SPECIFY MODEL GTW 200 GTW 400 SGW 600 SGW 800 SGW1000 SGW1200 SGW1400 SGW1600 LAF 400 LAF 600 LAF 800 LAF1000 LAF1200 LAF1400 LAF1600
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.5" 3.0" 4.5" 5.5" 6.5" 7.5" 8.5" 9.5" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0"
MAXIMUM OPENING 3.5" 6.0" 7.75" 10.25" 12.75" 15.25" 17.75" 20.25" 8.0" 12.0" 16.0" 20.0" 24.0" 28.0" 32.0"
EXPOSED SURFACE 4.25" 7.5" 9.5" 12.0" 14.5" 17.0" 19.5" 22.0" 7.62" 9.62" 11.62" 13.62" 15.62" 17.62" 19.62"
SPECIFY MODEL GTWC 200 GTWC 400 SGWC 600 SGWC 800 SGWC 1000 SGWC 1200 SGWC 1400 SGWC 1600 LAFC 400 LAFC 600 LAFC 800 LAFC 1000 LAFC 1200 LAFC 1400 LAFC 1600
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
LAFC
Shock Cord
ContinuousExtrudedAluminum Frame
Aluminum PanelDeflector
ES
Ceiling Cover
SGC
LAF
Wall Covers
Gasket Colors
AluminumPanel
Shock Cord Continuous ExtrudedAluminum Frame
Aluminum PanelDeflector
ES
Continuous FormedAluminum Frame
Turnbar
ES
Turnbar
National Archives II, MD
SGW
Gasket DisengagesTo Allow SeismicMovement
Continuous ExtrudedAluminum Frame
ES
Black White Gray Greige
Note: Custom colors available. Call 800-233-8493.
Corner Wall Covers
GTWC
GTW
Wall Covers
Gasket Continuous Extruded AluminumCover To Match Wall Finish
Continuous ExtrudedAluminum Frame
ES
ES
Continuous ExtrudedAluminum Center Plate
Gasket
Continuous ExtrudedAluminum Frame
Corner Wall Covers
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
AluminumHoney CombPanel
28 29For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Duracell Headquarters, CT
ALLWAY METAL
Wall & Ceiling COVERS 1"-4"
Use this cover for:
• Interior applications to match Allway metal floor covers.
• Standard aluminum covers supplied clear anodized, butKynar® paint and bronze or stainless top plates available.
How it works:
This wall cover’s free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish.
Corner Wall Covers Ceiling Covers
HCAFWCAFW
Wall Covers
HCW
Aluminum Anchor Clip
ESContinuous ExtrudedAluminum Center Plate
Continuous ExtrudedAluminum Cover Plate
W
ES
Dual DurometerPVC White Gasket
SuspendedAcoustical Ceiling(By Others)
ES
ES
Dual DurometerPVC White Gasket
W
W
W
ASMC ASM ES
Continuous ExtrudedWall Joint Cover SnapsInto Retaining Clip ForSimple Installation
2" Wide AluminumAnchor Clip
W
ES
W
Cover Edges GasketedFor Better Fit To Wall
JOINT WIDTH 1" 2" 3" 4" 1" 2" 3" 4" 1" 2" 3" 4"
MINIMUM OPENING 0.25" 0.5" 0.25" 1.0" 0.375" 0.375" 0.375" 0.375" 0.0" 0.0" 0.0" 0.0"
MAXIMUM OPENING 1.75" 3.5" 6.0" 7.0" 1.5" 3.0" 6.0" 6.0" 5.0" 6.0" 9.0" 10.0"
EXPOSED SURFACE 5.0" 7.75" 10.75" 11.75" 3.125" 4.625" 7.625" 7.625" 2.0" 3.0" 4.0" 5.0"
SPECIFY MODEL AFW 100 AFW 200 AFW 300 AFW 400 ASM 100 ASM 200 ASM 300 ASM 400 HC 100 HC 200 HC 300 HC 400
Model Data Wall Covers
Model Data Corner Wall Covers Model Data Corner Ceiling Covers
Model Data Ceiling Covers
JOINT WIDTH 1" 2" 3" 4" 1" 2" 3" 4" 1" 2" 3" 4"
MINIMUM OPENING 0.63" 1.25" 1.5" 2.5" 0.5" 0.5" 0.5" 0.5" 0.0" 0.0" 0.0" 0.0"
MAXIMUM OPENING 1.38" 2.75" 4.5" 5.5" 1.5" 3.0" 6.0" 6.0" 5.0" 6.0" 9.0" 10.0"
EXPOSED SURFACE 2.37" 4.25" 6.25" 7.25" 1.875" 3.375" 6.375" 6.375" 1.5" 2.5" 3.5" 4.5"
SPECIFY MODEL AFWC 100 AFWC 200 AFWC 300 AFWC 400 ASMC 100 ASMC 200 ASMC 300 ASMC 400 HCW 100 HCW 200 HCW 300 HCW 400
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
30 31
JOINT WIDTH 2" 3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16" 1.0" 2.0" 3.0" 4.0" 6.0" 8.0"
MINIMUM OPENING 0.75" 0.75" 0.75" 0.75" 2.0" 2.0" 2.0" 2.0" 2.0" 6.0" 6.0" 6.0" .05" 1.0" 1.5" 2.0" 3.0" 4.0"
MAXIMUM OPENING 3.0" 4.5" 6.0" 7.5" 9.0" 10.5" 12.0" 13.5" 15.0" 18.0" 21.0" 24.0" 1.5" 3.0" 4.5" 6.0" 9.0" 12.0"
EXPOSED SURFACE 2.0" 3.0" 4.0" 5.0" 6.0" 7.0" 8.0" 9.0" 10.0" 12.0" 14.0" 16.0" 1.0" 2.0" 3.0" 4.0" 6.0" 8.0"
SPECIFY MODEL SF 200 SF 300 SF 400 SF 500 SF 600 SF 700 SF 800 SF 900 SF 1000 SF1200 SF 1400 SF 1600 VF 100 VF 200 VF300 VF 400 VF 600 VF 800
Model Data Wall Covers
Model Data Wall Covers
JOINT WIDTH 4" 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"
MINIMUM OPENING 0.75" 0.75" 2.0" 2.0" 2.0" 2.0" 2.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0"
MAXIMUM OPENING 8.0" 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 22.0" 24.0" 26.0" 28.0" 30.0" 32.0"
EXPOSED SURFACE 4.0" 5.0" 6.0" 7.0" 8.0" 9.0" 10.0" 11.0" 12.0" 13.0" 14.0" 15.0" 16.0"
SPECIFY MODEL SC400 SC 500 SC 600 SC 700 SC 800 SC 900 SC 1000 SC 1100 SC 1200 SC 1300 SC 1400 SC 1500 SC 1600
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Ohio State University, OH
EXTERIOR WALL
Flexible Seals 2"-UP
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Wall Covers
Factory AppliedSilicone Face
ES
W
ES
W
Continuous ExtrudedSecondary Seal
VF
Wall Covers Wall Covers
SF-300
SC-400 SC-1200
W
W
W
TurnbarContinuous ExtrudedAluminum Frame
Continuous ExtrudedSantoprene Seal
Continuous ExtrudedAluminum Frame
Continuous ExtrudedSantoprene Seal
Cont. Extruded Alum.Center Mullion
Pantograph LoadSupport
Continuous ExtrudedAluminum Frame
ES
ES
SF-800C/S Supplied Adhesive
Impregnated CompressibleFoam BlockUse this cover for:
• Exterior vertical applications where weather protection is critical.
• Frames designed to attach to most external skin structures.
• 2" to 36" joint sizes with multi-directional movement.
• Factory welded transitions available.
• Four standard gasket colors (12 standard VF colors).
How it works:
Flush, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal.
SF-200 (typical cornercondition)
Note: Custom colors available. Call 800-233-8493.
Model VF Colors
Adobe Tan
Precast White
Dusty Rose
Limestone
Rustic Brick
Gray
Blue Spruce BlackCharcoalBronze
Natural Stone
SandstoneGasket Colors
Black White Gray Greige
JOINT WIDTH 8" 10" 12" 14" 16" 4" 8" 12" 16"
MINIMUM OPENING 4.0" 4.0" 4.0" 4.0" 4.0" 2.0" 2.0" 2.0" 2.0"
MAXIMUM OPENING 16.0" 20.0" 24.0" 28.0" 32.0" 8.0" 16.0" 23.0" 29.0"
EXPOSED SURFACE 17.31" 19.31" 21.31" 23.31" 25.31" 12.0" 18.0" 24.0" 30.0"
SPECIFY MODEL XLS 800 XLS 1000 XLS 1200 XLS 1400 XLS 1600 ESW 400 ESW 800 ESW 1200 ESW 1600
Model Data Wall Covers
JOINT WIDTH 8" 10" 12" 14" 16" 4" 8" 12" 16"
MINIMUM OPENING 4.0" 4.0" 4.0" 4.0" 4.0" 3.0" 5.0" 7.0" 9.0"
MAXIMUM OPENING 16.0" 20.0" 24.0" 28.0" 32.0" 7.5" 12.0" 17.5" 22.5"
EXPOSED SURFACE 13.0" 15.0" 17.0" 19.0" 21.0" 8.0" 13.0" 18.0" 23.0"
SPECIFY MODEL XLSC 800 XLSC 1000 XLSC 1200 XLSC 1400 XLSC 1600 ESC 400 ESC 800 ESC 1200 ESC 1600
Model Data Corner Wall Covers
3332 For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
de Young Museum, CA For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
SEISMIC
Exterior Wall COVERS 4"-UP
Use this cover for:
• Exterior seismic wall applications where cover concealment is desired within curtain wall finishes.
• Lightweight finish applications up to 9/16" thick (supplied by others).
• Zero maintenance required after an earthquake.
• Where high wind loads are expected.
How it works:
Flush exterior wall cover releases from wall on one side to provide full seismic movement. Cover returns to closed position after an event via counterweight system.
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
Wall Covers
ESW
XLS Expanded
Cycling
XLSXLS Contracted
XLSC ESC
Turnbar Vapor BarrierMoisture Seal
AluminumCover Plate
Wall Frame
Turnbar Vapor BarrierMoisture Seal
AluminumCover Plate
Wall PanelsField Installed,and Suppliedby Others
SS Hinge
ES
Extruded AluminumFrame
Strike Plate
Magnet
Ladder SystemAccepts Wide Rangeof Mounting Systemsand Panels
W
W
Wall PanelsField Installed,and Suppliedby Others
S.S. Hinge
ES
WeldedAluminumTube Frame
ControlAssemblyFrame
HingeFrame
Wall Substrate
W
Wall PanelsField Installed,and Suppliedby Others
Wall PanelsField Installed,and Suppliedby Others
ES
W
34 35For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
Round Valley Office Complex, NJ
Roof Covers 2"-UP
Use this cover for:
• Applications in built-up, flat roofs.
• Joint sizes from 2" to 36"
• Multi-directional movement requirements.
How it works:
For metal roof covers, aluminum frames create a seal tothe underside of sliding metal cover plates. For flexibleroof joint covers, bellows material expands and contractsfor multi-directional movement.
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.0" 1.0" 1.0" 1.0" 0.0" 0.0" 0.0" 0.0" 0.5" 0.5" 0.5" 0.5" 0.5" 0.5" 0.5"
MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 8.0" 11.5" 13.5" 17.5" 20.5" 21.5" 25.0"
EXPOSED SURFACE 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 22.0" 24.0" 12.0" 15.0" 18.0" 21.0" 24.0" 27.0" 30.0"
SPECIFY MODEL BRJ 200 BRJ 400 BRJ 600 BRJ 800 BRJ 1000 BRJ 1200 BRJ 1400 BRJ 1600 SRJ 400 SRJ 600 SRJ 800 SRJ 1000 SRJ 1200 SRJ1400 SRJ 1600
Model Data Roof Covers
Model Data Roof to Wall Covers
JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"
MINIMUM OPENING 1.0" 1.0" 1.0" 1.0" 1.0" 0.0" 0.0" 0.0" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5"
MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 6.5" 8.5" 11.0" 13.5" 16.0" 18.5" 21.0"
EXPOSED SURFACE 6.0" 8.0" 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 8.0" 10.5" 13.0" 15.5" 18.0" 20.5" 23.0"
SPECIFY MODEL BRJW200 BRJW 400 BRJW 600 BRJW 800 BRJW 1000 BRJW 1200 BRJW 1400 BRJW 1600 SRJW 400 SRJW 600 SRJW 800 SRJW 1000 SRJW 1200 SRJW 1400 SRJW 1600
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
Roof To Wall Covers Specialty Roof Joint CoversHigh Movement and High Wind Loads
Gyrometric Cover
SRJWSRJ
BRJ
Roof To Roof Covers
Parapet Transitions
BRJW
WW
Turnbar
AluminumCover Plate
Vapor Barrier
ExtrudedAluminumFrame
Moisture Seal
W
ExtrudedSecondary Seal(Optional)
ContinuousMetal Retainer
Furnace Bellows
Closed CellFoam
AluminumRetainer
W
FactoryFabricated EndTransition TucksUp BehindVertical Seal
Factory Fabricated BaseClosure For Vertical Seal
Composite Design toMeet Project Wind Loadsand Movement Criteria
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
36 37
JOINT WIDTH 4" 6" 8" 6" 8" 10" 12" 14" 16" 4" 6" 8"
MINIMUM OPENING 2.0" 3.0" 4.0" 0.0" 0.0" 0.0" 0.0" 0.0" 0.0" 1.25" 1.25" 1.25"
MAXIMUM OPENING 6.0" 9.0" 12.0" 11.0" 13.0" 16.0" 19.0" 22.0" 25.0" 5.25" 8.0" 10.25"
EXPOSED SURFACE 17.0" 22.0" 26.0" 24.5" 26.5" 29.5" 32.25" 35.25" 38.25" 7.63" 11.13" 14.13"
SPECIFY MODEL KB 400 KB 600 KB 800 PTC 600 PTC 800 PTC 1000 PTC 1200 PTC 1400 PTC 1600 KBW400 KBW600 KBW800
Model Data Floor to Floor Covers Model Data Floor to Wall Covers
Model Data Floor to Floor Covers
JOINT WIDTH 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" .87" 1.68" 2.56" 3.43"
MINIMUM OPENING 1.0" 1.5" 2.0" 0.6" 1.13" 1.5" 2.0" 0.43" .87" 1.37" 1.81"
MAXIMUM OPENING 3.0" 4.5" 6.0" 1.5" 3.0" 4.5" 6.0" 1.25" 2.5" 3.75" 5.0"
EXPOSED SURFACE 9.0" 10.0" 11.0" 1.0" 2.0" 3.0" 4.0" 0.87" 1.68" 2.56" 3.43"
SPECIFY MODEL ZB200 ZB300 ZB400 HB100 HB200 HB300 HB400 HBF100 HBF200 HBF300 HBF400
For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers
For odd and larger sized joints, call (800) 233-8499 or visit www.c-sgroup.com
PARKING
Covers & Seals 1"-16"
Use this cover for:
• Seismic applications in parking and other areas with vehicular access.
• Available in standard or HS-20 heavy duty loading.
• New Cast-In-Place Model Available for post-tensioned slab applications.
How it works:
For a complete description call (800) 233-8493 and requesta parking cover catalog or go to www.c-sgroup.com
Annapolis City Marina Parking, MD
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
JOINT WIDTH
MINIMUM OPENING
MAXIMUM OPENING
EXPOSED SURFACE
SPECIFY MODEL
ZB
KBC
W
WW
SealantOne-Piece EPDM Seal Bonded inan Epoxy Bed for Fast Installation
For Cast-In PlaceApplications Vapor Barrier
PTCW
CompressionSpring
ElastomericConcrete
ExtrudedAluminumFrame
AluminumCover Plate
Leveling Grout (By Others)
Extruded AluminumRotational Frame
Vapor Barrier
PDA
HBFW
Installedwith EpoxyAdhesive
Neoprene Seal
HBW
“Hybrid” Compression SealIncorporating Built In Reservoirsfor Epoxy Adhesive
No InflationNeeded
KBW For Joint Sizes up to 9"
with 50% Movement
RemovableVapor Barrier
Turnbar Housing PreventsShearing of Bolts
Aluminum Top Cap(Stainless Steel Optional)
CompressionSeal
ExtrudedAluminum Side Frame
ESElastomericConcrete
When an expansion or seismic joint passes through afire-rated structure it is necessary to maintain the fire
integrity of that structure. Maintaining the integrity of a
2" wide joint is quite simple; however, a joint designed
for seismic movement up to 24 inches becomes a more
difficult proposition. In general, the wider the joint, the more complex the fire barrier. Most
manufacturers use the same barrier design for all joint
sizes. C/S has simplified our fire barrier for small joint
sizes for easy installation and to maximize cost
effectiveness (see Reflex). Floor applications are relatively simple configurations regardless of joint size
unless lateral shear is required. Walls, on the other hand,
can be more complex. All C/S fire barriers require only
one barrier in the wall and require that the studs be
wrapped with drywall to maintain full integrity.
(Includes shaft walls) Variations in wall configurationsand finishes, as well as transitions between adjacent fire barriers, make it critical to consult the manufacturer
concerning typical applications. C/S has a technical
expert available to assist you in detailing these
applications. Since 1996 building codes require firebarriers to limit the passing of heat and flame for 2, 3
and sometimes 4 hours, as well as accommodating the
dynamic movement for which the joint was designed.
ASTM E 1966 and UL 2079 specify criteria for “cycling”
a fire barrier 500 times prior to fire testing. C/S tests
all of its fire barriers at Underwriters Laboratories
(UL) because they represent the most stringent
and universally accepted testing authority.
“LS” designation indicates a special adaptation of the floor fire barrier to accommodate Lateral Shear movement.FB-97 wall fire barriers naturally provide lateral shear movement.
Reflex® 1"- 4" Stainless steel foil drape with block insulation affords maximum economy in materialand installation. Wall barriers limited to 1” - 4” joints and require no stainless foil.
NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL
1 RFX-1F FF-D-0044 RFX-1W (GYP.) WW-D-0048 RFX-1W(CONC) WW-D-0050
RFX-1X FF-D-0044 RFX-1W (1 HR GYP.) WW-D-0059 RFX-1W(1 HR CONC.) WW-D-0060
2 RFX-2F FF-D-0045 RFX-2W (GYP.) WW-D-0049 RFX-2W(CONC) WW-D-0051
RFX-2F FF-D-0045 RFX-2W (1 HR GYP.) WW-D-0061 RFX-2W(1 HR CONC.) WW-D-0062
3 RFX-3F FF-D-1055
4 RFX-4F FF-D-1065FOR WALL APPLICATIONS OVER 2" PLEASE SEE MULTIFLEX OFFERING
Multiflex® 3"-12"“Sandwich” assembly of layers of stainless steel foil and insulation contained in a stainless steelmesh. Standard barrier allows up to 50% lateral shear in floor applications.
FB97 13"-UpMultiple drape configurations of stainless foil and insulation utilizing air pockets for additionalinsulation performance. Sliding frame available for 100% lateral shear applications in floors.
NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL
13-24 FB97-13-24 FF-D-3005 FB97-13-24(GYP) WW-D-3007 FB97-13-24(CONC) WW-D-3008
25-36 FB97-25-36 FF-D-4001 NA NA NA NA
13-24 FB97-13(LS)-24(LS) FF-D-3006 NA NA NA NA
25-36 FB97-25(LS)-36(LS) FF-D-4002 NA NA NA NA
NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL
3-6 MFX-3F-6F FF-D-1066 MFX-3W-6W(GYP) WW-D-1056 MFX-3W-6W(CONC) WW-D-1057
7-12 MFX-7F-12F FF-D-2009 MFX-7W-12W(GYP) WW-D-2011 MFX-7W-12W(CONC) WW-D-2012
UL TestingAll C/S Fire Barriers are tested rigorously at Underwriters Laboratories,including UL 2079 “Cycling” Tests.
NO MATTER WHAT JOINT COVER YOU NEED,
We’ve got the right fire barrier.CHOOSE THE F IRE BARRIER THAT BEST SUITS YOUR PROJECT.
For the nearest C/S representative, or literature and samples, call toll free 800-233-8493 in U.S.A. and 888-895-8955 in Canada, or visit www.c-sgroup.com
©Copyright 2009 Construction Specialties, Inc.
Construction Specialties, Inc. reserves the right to make design changes or to withdraw any design without notice. Printed in U.S.A. Series 10
The C/S Family of Products
For more than 60 years, Construction Specialties has been a leader in architectural specialty products, including: Acrovyn® Wall and Door Protection, Pedisystems® EntranceFlooring, Expansion Joint Covers, Cubicle Track and Curtains, Smoke and Explosion Venting Systems, Architectural Grilles,Architectural Louvers and Sun Controls.
We have operations throughout the world and can provide C/S Products virtually anywhere. For a complete list of our international locations, visit www.c-sgroup.com.
6696 State Route 405, Muncy, Pennsylvania 17756 U.S.A., 570-546-5941
895 Lakefront Promenade, Mississauga, Ontario L5E 2C2 Canada, 905-274-3611
www.c-sgroup.com