ejc catalog

21
C/S Expansion Joints @ The Cathedral of Christ the Light 07 95 00/CON BuyLine 1803

Upload: teodor-baniski

Post on 28-Apr-2015

107 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Ejc Catalog

C/S Expansion Joints @ The Cathedral of Christ the Light

07 95 00/CON

BuyLine 1803

Page 2: Ejc Catalog

Pasadena City Hall was built in 1927 to inspire a city with beauty, boldness and

vision. It is an important part of this community’s rich architectural heritage. It is one

of the finest examples of the California Mediterranean style. Designed by Bakewell

and Brown in San Francisco, the 80 year old Pasadena City Hall is one of the mostdistinctive public buildings in the United States and is listed on the

National Register of Historic Places. One of the primary reasons for the seismic

retrofit of Pasadena City Hall was that studies in the 1990s indicated that major

earthquakes in the future could destroy several parts of the building completely

and result in loss of life. In 2003, the City Council approved a plan for the seismicretrofit and historic restoration. Seismic retrofit of the building included the

installation of structural base isolators that now allow the

building to withstand future earthquake activity.  Restoration

activities were undertaken to preserve many of the historic

architectural elements of City Hall.

An 80 year old architectural icon gets a seismic makeover.

P A S A D E N A C I T Y H A L L C/S Expansion Joint Coverson the job

Pasadena City Hall achieves LEED® Gold status

Along with the seismic upgrade, the City ofPasadena requested that the building be LEED®Certified. The design team used sustainable strategies throughout the project. Even the C/Sexpansion joint covers in the patio area are hidden beneath a 4" layer of decomposed granite.

Architect: Architectural Resources Group (ARG) San Francisco, CAConstruction Manager: DM-JMH+NContractor: Clark Construction Group

C/S Stone Paver Seismic Covers allowthe Pasadena City Hall to move 30"

For the seismic upgrade of the Pasadena CityHall ARG architects specified 33" SSRW SeismicStone Paver Floor Covers to fill the moat areasurrounding the building’s perimeter in itsinner courtyard. The covers provide full fourway movement and are designed to work inconjunction with the base isolators when aseismic event occurs.

Page 3: Ejc Catalog

No matter how much movement your project requires, we can hide it.C / S E X P A N S I O N J O I N T C O V E R S

C/S @ Orange County Performing Arts CenterIn the interior of the magnificent Segerstrom Concert Hall,Architect Pelli Clarke Pelli specified C/S 12" LAF Seismic WallCovers. Virtually imperceptible the LAF wall covers are lightweight, match the concert hall’s wall finish without visual interruption and provide full movement of the joint without damage to surrounding wall surfaces.

54

C/S @ de Young MuseumA major consideration of the de Young project was that theexpansion joint covers must be “virtually invisible” within the museum’s weathered copper skin. Architects Fong & Chan,SF; and Herzog & de Meuron specified CS’ XLS cover system knowing it could be seamlessly incorporated into the facade’scopper panel frame. The 24" XLS covers are designed to release from the wall to provide full seismic movement.

Page 4: Ejc Catalog

Solving complex building movement problems for 40 yearsC / S E X P A N S I O N J O I N T C O V E R S

C/S supplied unobtrusive SM-2 Wall Covers to match blend surrounding wall surfacesand to provide multi-directional thermalmovement in order to keep the facility walls from cracking.

Throughout San Francisco InternationalAirport’s base isolated main terminal,massive C/S wall floor and ceiling coversprovide four way movement up to 60"while being virtually invisible. The SSRStone Paver floor joints are 200' long and provide 36" of movement.

San Francisco International AirportArchitect: Skidmore, Owings & Merrill

NewseumArchitect: Polshek Partnership

A seismic upgrade was required for thislandmark building. Parsons specified C/SGyrometric cabs (Model MACC) and SSRWSeismic moat covers to provide egressfrom the building during seismic activity.

Utah State Capitol BuildingProject Manager: Parsons Corporation

Center for the Intrepid Armed Forces PhysicalRehabilitation CenterArchitect: The Smith Group

To provide movement and securitybetween the Newseum and the adjacentCanadian Embassy, Polshek Partnershipspecified SC-1200 Exterior Covers andSRJ-1200 Roof Covers that tie both buildings together. The covers with factory mitered transitions are attached to the building’s delicate marble surface.

Page 5: Ejc Catalog

9

Drywall, ceramic tile

Drywall, ceramic tile

Drywall, panel systems, metalcladding, stone

All finishes All finishes All roof finishes Concrete, paver

Minimum exposedsurface, sealed gasket installation

Minimum exposedsurface, sealed gasket installation,larger movement

Minimum exposedsurface, optionalsealed gasketinstallation, seismicmovement

Robust applications, lowmaintenance, full movement range

Minimum exposedsurface, sealed gasket installation, full movement range

Formed aluminumand EPDM bellowsoptions, full movement range

Exterior, waterproof applications, full movement range

Flush Thinline Gasketed

Flush Twinline Dual Gasketed

Seismic FlushTwinline

Allway Metal Exterior Wall Roof Parking &Stadiums

1" to 4" 2" and up 4" and up 1" to 4" 2" and up 2" and up 1" to 16"

Hygienic, matches Thinlinefloor covers

24-25

8-9

N/A

ReflexPage 39

Hygienic, matches Twinlinefloor covers

26-27

10-11

N/A

MultiflexPage 39

All commercial andhealthcare interiorsand exteriors

26-27

12-15

N/A

Multiflex or FB-97Page 39

Industrial, matchesAllway floor covers

28-29

16-17

N/A

Reflex or Multiflex Page 39

All exteriors,colorable

30-33

N/A

N/A

ContactFactory

All roofs

34-35

N/A

N/A

ContactFactory

Vehicular traffic, stadium seatingbowls and concourse

36-37

N/A

N/A

ContactFactory

25-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

25-100% Of Joint Width

By assigning our metal systems a cost of 100, you can determine how much an alternate system of similar size will cost.

This catalog is designed to convey the design concept and variations available with C/S joint cover systems–for more accurate details go to: www.c-sgroup.com

55 180 N/A 100 150 N/A N/A

1008

Selection Chart

The size of joint and movement dynamics dictate whether you

require a standard or seismic expansion joint cover system. Before

making a selection, there are other decisions you must make. The

selection of the floor cover is often the most critical step in the

specification process since the performance of the floor cover has the

greatest impact on the occupants of the building. The presence of rolling

loads and the need for hygiene are major considerations in cover

selection, while aesthetics in seismic covers is also a significant issue.

Joint Size

Appearance

Cover Type

Description

Finishes

Designed For

% Movement +/-

Page #

Matching Floor

Wall/Ceiling

Fire Barriers

Cost Index

Minimum exposedsurface, sealed gasket installation

Carpet, vinyl,ceramic tile, terrazzo, stone

Hygienic, wheeled equipment

10-11

N/A

24-25

ReflexPage 39

Carpet, vinyl Carpet, vinyl, terrazzo, stone

Concrete, carpet,vinyl

Concrete, pavers,carpet, vinyl,ceramic tile

Carpet, vinyl

Minimum exposedsurface, sealed gasket installation,larger movement

Minimum exposedsurface, optionalsealed gasketinstallation, seismicmovement

Robust applications, low maintenance

Robust applications, low maintenance,seismic movement

Corridors in base isolated structures withmulti-directionalmovement

1" and 2"

Flush ThinlineGasketed

Flush TwinlineDual Gasketed

Flush Seismic,Seismic Pan

Standard Allway Metal

Seismic Allway Metal

SeismicCorridor Cover

2" to 4" 4" and up 1" to 4" 4" and up 4" to 36"

65

Hygienic, wheeled equipment

12-13

N/A

24-25

MultiflexPage 39

Hygienic, wheeled equipment, deepfloor finish materials,also exterior

14-17

N/A

26-27

Multiflex or FB-97Page 39

Industrial, heavy wheeledequipment

18-19

N/A

28-29

ReflexPage 39

Industrial, heavy wheeled equipment, alsoexterior

20-21

N/A

26-27

MultiflexPage 39

Commercial and healthcareinteriors

22-23

N/A

22-23

FB-97Page 39

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50% Of Joint Width25% Of Joint Width

All C/S Expansion Joint Covers, Seals and Processes are ISO 9001: 2000 compliant.

Floor Covers

105 125 100 100 N/A

Specialty covers, such as roof covers

and vehicular joint systems, are

available for most joint sizes and

movement dynamics.

Having selected the floor cover, identifying a matching wall cover is a relatively simple task.

When it comes to seismic covers, however, there are options driven by both functionality and

aesthetics. Choose from covers that become detached from the wall to minimize damage or

ones that are self-closing to minimize post-event maintenance. Many of our wall covers are

designed to accept a range of surface materials to maximize concealment of the cover.

Wall & Ceiling Covers Specialty Covers

Page 6: Ejc Catalog

1110

FLUSH

Thinline Floor COVERS 1"-2"

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Miami International Airport, FL

Model Data Floor to Wall Covers

Model Data Floor to Floor Covers

1" 2" 1" 2" 1" 2" 1" 2"

MINIMUM OPENING 0.75" 1.5" 0.75" 1.5" 0.75" 1.5" 0.75" 1.5"

MAXIMUM OPENING 1.25" 2.5" 1.25" 2.5" 1.25" 2.5" 1.25" 2.5"

EXPOSED SURFACE 1.12" 1.88" 1.18" 1.88" 2.63" 3.56" 2.63" 3.56"

SPECIFY MODEL GFTW 100 GFTW 200 GFPSW 100 GFPSW 200 GFSW 100 GFSW 200 GFSTW 100 GFSTW 200

1" 2" 1" 2" 1" 2" 1" 2"

MINIMUM OPENING 0.75" 1.5" 0.75" 1.5" 0.75" 1.5" 0.75" 1.5"

MAXIMUM OPENING 1.25" 2.5" 1.25" 2.5" 1.25" 2.5" 1.25" 2.5"

EXPOSED SURFACE 1.25" 1.88" 1.18" 1.88" 4.31" 5.13" 4.31" 5.06"

SPECIFY MODEL GFT 100 GFT 200 GFPS 100 GFPS 200 GFS 100 GFS 200 GFST 100 GFST 200

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

Use this cover for:

• Applications with small, interior joints where minimal visual impact is preferred.

• Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish.

• Where wheeled equipment is to be used.

• Where hygiene is important.

How it works:

Single gasket expands and compresses during movement. 2" model includes aluminum support plate for added durability.

Gasket Colors

Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Non-ShrinkGrout

Gasket

Floor to Wall Covers Floor Covers

GFTW-100GFT-100

Floor Covers

GFT-200

GFPS-100 GFST-200

Floor Finish

W

Carpet

WContinuous ExtrudedAluminum Frame

W

W

Non-ShrinkGrout

Continuous ExtrudedAluminum Frame

ContinuousExtrudedCentralPlate

FloorFinish

Continuous ExtrudedAluminum Wall Frame

W Continuous ExtrudedAluminum Frame

GFTW-200 GFPS-200 GFS-200W

Carpet

W

Continuous ExtrudedAluminum Wall Frame

W

1"-3"

1"-3 "

1"-3"

1"-3"

Gasket

ES

ES

ES

ES

ES

ES

ES

ES

Page 7: Ejc Catalog

Model Data Floor to Wall Covers

JOINT WIDTH 2" 3" 4" 2" 3" 4" 2" 3" 4"

MINIMUM OPENING 1.0" 1.5" 2.0" 1" 1.5" 2" 1.0" 1.5" 2.0"

MAXIMUM OPENING 3.0" 4.5" 6.0" 3" 4.5" 6" 3.0" 4.5" 6.0"

EXPOSED SURFACE 6.5" 10.0" 11.0" 6.5" 10" 11" 6.5" 10.0" 11.0"

SPECIFY MODEL GTR 200 GTR 300 GTR 400 GTR-HD 200 GTR-HD 300 GTR-HD 400 GTP 200 GTP 300 GTP 400

Model Data Floor to Floor Covers

12 13For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Inova Fairfax Hospital, VA

FLUSH

Twinline Floor COVERS 2"-4"

Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH 2" 3" 4" 2" 3" 4" 2" 3" 4"

MINIMUM OPENING 1.5" 2.25" 3.0" 1.5" 2.25" 3.0" 1.5" 2.25" 3.0"

MAXIMUM OPENING 2.5" 3.75" 5.0" 2.5" 3.75" 5.0" 2.5" 3.75" 5.0"

EXPOSED SURFACE 4.25" 6.5" 7.5" 4.31" 6.56" 7.56" 4.25" 6.5" 7.5"

SPECIFY MODEL GTRW 200 GTRW 300 GTRW 400 GTPW-HD 200 GTPW-HD 300 GTPW-HD 400 GTPW 200 GTPW 300 GTPW 400

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

Use this cover for:

• Applications with larger thermal movement requirements and where a flush, concealed cover is preferred.

• Applications using carpet or vinyl floor covering up to 1/8" deep.

• 3/8” Recessed center plate available.

• Where wheeled equipment is expected.

• Where hygiene is important.

How it works:

Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening.

Floor to Wall Covers Floor CoverHeavy Duty 2,000 lb. Point Load

GTPW-HD(Heavy Duty)

GTRWGTR

GTPW

GTR-HD(Heavy Duty)

GTP

Floor Covers

Gasket Colors

ES

Continuous ExtrudedAluminum Frame

GasketContinuous ExtrudedAluminum RecessedCenter Plate 1/4" Aluminum

Center Plate

ES

Heavy Duty Frame

Floor FinishMatching(By Others)

ES

ES

GasketContinuous ExtrudedAluminum Flush Center Plate

5/8"

5/8" 5/8"

Floor Finish(By Others)

Continuous ExtrudedAluminum Frame

ES

5/8"

ES

3/4"

3/4"

W W W

W W W

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Page 8: Ejc Catalog

14 15

JOINT WIDTH 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"

MINIMUM OPENING 2.5" 2.5" 2.5" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0"

MAXIMUM OPENING 8.0" 9.0" 11.0" 12.0" 14.0" 15.0" 17.0" 18.0" 20.0" 21.0" 23.0" 24.0"

EXPOSED SURFACE 12.0" 13.0" 15.0" 16.0" 18.0" 19.0" 21.0" 22.0" 24.0" 25.0" 27.0" 28.0"

SPECIFY MODEL SGR 500 SGR 600 SGR 700 SGR 800 SGR 900 SGR 1000 SGR 1100 SGR 1200 SGR 1300 SGR 1400 SGR 1500 SGR 1600

Model Data Floor to Floor Covers

JOINT WIDTH 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"

MINIMUM OPENING 4.0" 4.5" 5.25" 5.5" 5.75" 6.25" 6.75" 7.25" 7.75" 8.25" 8.75" 9.25"

MAXIMUM OPENING 7.0" 8.0" 9.5" 10.5" 12.0" 13.0" 14.5" 15.5" 17.0" 18.0" 19.5" 20.5"

EXPOSED SURFACE 8.5" 9.5" 11.0" 12.0" 13.5" 14.5" 16.0" 17.0" 18.5" 19.5" 21.0" 22.0"

SPECIFY MODEL SGRW 500 SGRW 600 SGRW 700 SGRW 800 SGRW 900 SGRW 1000 SGRW 1100 SGRW 1200 SGRW 1300 SGRW 1400 SGRW 1500 SGRW 1600

Model Data Floor to Wall Covers

Floor Covers Floor to Wall Covers

Gaskets Disengage to AllowFull Seismic Movement

“Turnbar” Rotates and Keeps Plate Centered During Movement Cycle

Hinged Side Frame

Hinged Side Frame

SGPW

SGR*SGR Contracted

SGP*

SGRW

SGR Expanded

Cycling

Gasket Colors

Plate Deflectors Ensure System RemainsOperable through Major Seismic Activity

W

W

W

W

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

40 Bank Street, London SGR and SGP have same model data. SGRW and SGPW have same model data. For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

FLUSH

Seismic Floor COVERS 5"-UP

Black White Gray Greige

3/4"

3/4"

3/4"

3/4"

Use this cover for:

• Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes.

• Applications using carpet or vinyl floor covering up to 1/8" deep.

• Where wheeled equipment is expected.

• Where hygiene is important.

How it works:

Dual gaskets expand and contract during minor thermal movement. During full seismic activity, gaskets disengage and the aluminum center plate that spans the joint opening temporarily displaces.

*Can be modified to provide up to 100% movement

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

ES

ES

ES

ES

Note: Custom colors available. Call 800-233-8493.

Page 9: Ejc Catalog

Model Data Floor to Wall Covers

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.0" 2.5" 3.0" 4.0" 4.0" 4.0" 4.0" 4.0"

MAXIMUM OPENING 3.0" 9.0" 11.0" 12.5" 15.5" 18.5" 21.5" 24.5"

EXPOSED SURFACE 10.88" 12.88" 14.88" 18.6" 20.5" 23.75" 26.75" 32.75"

SPECIFY MODEL SSR 200 SSR 400 SSR 600 SSR 800 SSR 1000 SSR 1200 SSR 1400 SSR 1600

Model Data Floor to Floor Covers

1716

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.0" 1.5" 2.0" 4.0" 4.0" 4.0" 4.0" 4.0"

MAXIMUM OPENING 3.0" 6.5" 8.5" 10.25" 12.75" 15.25" 17.75" 20.25"

EXPOSED SURFACE 6.44" 8.44" 10.44" 14.38" 16.88" 19.38" 21.88" 24.32"

SPECIFY MODEL SSRW 200 SSRW 400 SSRW 600 SSRW 800 SSRW 1000 SSRW 1200 SSRW 1400 SSRW 1600

SSR Contracted

Cycling

SSR Expanded

Floor Covers Floor to Wall Covers

SSRW-800

SSR-200-600

SSR-800

SSRW-400ContinuousAluminum Frame

ES

ExtrudedAluminumCenter Pan

2-1/4"

InfillMaterial

Continuous Aluminum Pan Nosing

SealantandBacker

Aluminum Hinge

2-1/4"

2-1/4" 2-1/4"

Center Pan Lifts Clear Of Moving StructureBut Remains Centered Over Opening

Unique Gravity Activated Turnbar System ReturnsCover To Normal Position After Event

Can be used As “Moat Cover” For Base Isolated Structures

Modular Pan ConstructionFor High Strength

Unit Sealed WithStandard Caulking

W

W W

ES ES

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

San Francisco International Airport, CA

W

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

PAN

Seismic Floor COVERS 4"-UP

Use this cover for:

• Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes.

• Applications with floor finishes of up to 1-1/2" thick.

• Heavy duty versions available for limited vehicular access.

How it works:

Sealant and Backer Rod expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

ES

Page 10: Ejc Catalog

Model Data Floor to Wall Covers

18 19

JOINT WIDTH 2" 4" 2" 4" 2" 4" 2" 4" 2" 4"

MINIMUM OPENING 1.0" 2.5" 1.0" 2.5" 1.0" 2.0" 0.0" 0.0" 1.0" 2.5"

MAXIMUM OPENING 3.0" 5.5" 3.0" 5.5" 3.0" 5.5" 3.5" 6.5" 3.0" 5.5"

EXPOSED SURFACE 2.82" 5.18" 4.87" 7.87" 6.75" 8.25" 3.75" 6.75" .081" 1.25"

SPECIFY MODEL ALRW 200 ALRW 400 ALSW 200 ALSW 400 ALW 200/HD ALW 400/HD PCW 200 PCW 400 FYWW 200 FYWW 400

Floor to Wall Covers

ALRW

ALSW

PCW

W

Continuous Extruded AluminumPlate For Carpet/Vinyl

Continuous Extruded AluminumFloor To Wall Frame

W

ES

Continuous Extruded Aluminum Serrated Plate

Continuous Extruded AluminumFloor To Wall Frame

W

ES

ES

Continuous Extruded AluminumFloor To Wall Cover Plate

1"

1"

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Chek Lap Kok Airport, Hong Kong

Model Data Floor to Floor Covers

JOINT WIDTH 1" 2" 4" 2" 4" 2" 4" 2" 4" 2" 4" 2" 4"

MINIMUM OPENING .7" 1.5" 3.1" 0.0" 1.0" 0.0" 1.0" 0" 1.0" 0.0" 0.0" 1.0" 2.5"

MAXIMUM OPENING 1.2" 2.5" 4.7" 4.0" 7.0" 4.0" 7.0" 4.0" 7.0" 3.5" 6.5" 3.0" 5.5"

EXPOSED SURFACE 1.7" 3.25" 5.25" 3.65" 6.43" 7.75" 11.75" 9.00" 12.50" 5.25" 8.25" .081" 1.25"

SPECIFY MODEL APF 25 APF 50 APF 100 ALR 200 ALR 400 ALS 200 ALS 400 AL 200/HD AL 400/HD PC 200 PC 400 FYW 200 FYW 400

STANDARD ALLWAY

Metal Floor COVERS 1"-4"

APFW

Continuous Extruded Aluminum Center Plate Insert

Continuous ExtrudedAluminum Cover Plate

ES

AL-HD

FYW

Specify Heavy Duty Model AL-HD For 2000 lb. Rolling Loads

W

Continuous Extruded Aluminum Frame

Continuous Extruded AluminumSerrated Cover Plate

1"

ES

W

1/4” & 1/8” Carpet

1"

ES

Extruded Aluminum Frame

Gasket Colors

ALR

Floor Covers

ALS

PC

Recessed Cover PlateContinuous ExtrudedAluminum Center Plate

W

W

ES

1/8” Floor Finish (ByOthers)

Continuous ExtrudedAluminum Frame

Serrated Side Plates Create A More Flush Surface,But Impact Visibility

Continuous ExtrudedAluminum Center Plate

Extruded AluminumFrame

1"

1"

W

Continuous ExtrudedAluminum Cover Plate

ES

Floor Covers

Note: All joint systems on this page are available for 1"-4" joints. Contact factory if required size is not listed.

Use this cover for:

• Use APF Series for applications with heavy rolling loads.

• Interior applications where low maintenance is desirable or for tamperproof applications.

• Suitable for most floor finishes – frame configuration variable to suit selected finish.

How it works:

Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

ES

Page 11: Ejc Catalog

20 21

JOINT WIDTH 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 2.0" 3.0" 3.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"

MAXIMUM OPENING 6.0" 9.0" 13.0" 3.5" 6.5" 9.75" 4.38" 7.0" 11.5" 13.5" 17.0" 20.0" 23.0" 25.5"

EXPOSED SURFACE 8.75" 11.75" 14.75" 5.5" 8.5" 11.5" 3.5" 7.5" 11.88" 15.0" 17.88" 21.0" 23.88" 27.0"

SPECIFY MODEL SJ-HD400 SJ-HD600 SJ-HD800 SJPF 200 SJPF 400 SJPF 600 SJP 200 SJP 400 SJP 600 SJP 800 SJP 1000 SJP 1200 SJP 1400 SJP 1600

Model Data Floor to Floor Covers

SJPF*

Floor Covers

SJHD*Heavy Duty 2,000 lb. Point Load

Floor to Wall Covers Floor Covers

SJP*

SJPFW*

SJWHD*Heavy Duty 2,000 lb. Point Load

SJPFB/SS*W

Continuous ExtrudedAluminum Side Frame

Continuous ExtrudedAluminum Frame

AluminumCenter Plate

Non-ShrinkGrout

FloorFinish

W

ES

ES

W

Bronze or Stainless Center Plate

ES

W

Continuous ExtrudedAluminum HD Frame

Continuous ExtrudedAluminum Frame

ES

Heavy Duty Frame

W

FormedAluminumCenter Plate ES

Aluminum Center Plate May be Bronze or Stainless Steel

W

1-1/8" 1-1/8"

1-3/8" 1-1/2"

TurnbarAssembly

ES

1-1/8"

1-3/8"

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Banner Gateway Medical Center, AZ

JOINT WIDTH 4" 6" 8" 2" 4" 6" 2" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 3.0" 4.25" 5.0" 1.0" 1.0" 1.0" 0.5" 2.25" 3.25" 4.38" 5.38" 6.38" 7.38" 8.38"

MAXIMUM OPENING 5.0" 7.5" 10.5" 3.0" 5.25" 7.88" 3.13" 5.5" 8.5" 11.0" 13.5" 16.0" 18.5" 21.0"

EXPOSED SURFACE 6.38" 8.88" 12.38" 3.75" 6.25" 8.75" 3.24" 5.75" 9.0" 11.5" 14.0" 16.5" 19.0" 21.5"

SPECIFY MODEL SJW-HD400 SJW-HD600 SJW-HD800 SJPFW 200 SJPFW 400 SJPFW 600 SJPW 200 SJPW 400 SJPW 600 SJPW 800 SJPW 1000 SJPW 1200 SJPW 1400 SJPW 1600

Model Data Floor to Wall Covers

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

SEISMIC ALLWAY

Metal Floor COVERS 4"-UP

Use this cover for:

• Interior or exterior seismic applications where aesthetics are not a primary concern.

• Limited vehicular access (heavy duty models).

How it works:

Self centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slidesover floor surface during seismic movement.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

Turnbar

*Can be modified to provide up to 100% movement.

Page 12: Ejc Catalog

22 23

How the Gyrometric Cover Works

Full Closed (During Compression) During an event in the contraction or compression mode the cab slides fully into the adjoining structure.

Lateral Shear The cab is attached to the fixed structure by means of a friction-freesliding track assembly to allow full lateral shear between buildings.

Full Open (During Tension) During an event in the expansionor tension mode the cab slides fully out.

SEISMIC

Corridor CoversFOR BASE ISOLATED STRUCTURES

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

de Young Museum, CA

Floor/Wall Section

Typical Floor Section

Cover Details

Unique Honeycomb StructureSupports Plate ThroughoutMovement Cycle

Also Available As AConventional LinealCover, Model XYZ

Center Pan Locked Into And GuidedBy Track At Base Of Side Walls

This system allows full access between base isolated and

fixed structures. It is perfect for where egress is necessary

during an earthquake. Because base isolated structures are

free to move in any horizontal direction, they create

distinct challenges for the design of the seismic joint covers.

The C/S solution for base isolated structures is an integrated

assembly approach with floor, wall and ceiling covers connected

and moving in unison. This Gyrometric System, or “cab

assembly,” provides full movement of up to 100% in

any horizontal direction. The floor cover may be used

independently of the wall and ceiling covers for lineal

applications where lateral shear is a problem

(specify model XYZ).

•OSHPD approved designs

• Complies with ASTM E1399

• Complimentary pre-construction design assistance

• Fire rating available; compliant with UL 2079

• Wide range of custom finishes available

• Virtually any joint size/movement capability can be accommodated

Page 13: Ejc Catalog

24 25

Gasket Colors

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Ontario Convention Center, CA

Model Data Wall to Wall Covers

Model Data Corner Wall Covers

JOINT WIDTH 1" 2" 3" 4" 2" 3" 4" 1" 2" 3" 4" 2" 3" 4"

MINIMUM OPENING 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"

MAXIMUM OPENING 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0" 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0"

EXPOSED SURFACE 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0"

SPECIFY MODEL FWF 100 FWF 200 FWF 300 FWF 400 FWS 200 FWS 300 FWS 400 FCF 100 FCF 200 FCF 300 FCF 400 FCS 200 FCS 300 FCS 400

JOINT WIDTH 1" 2" 3" 4" 2" 3" 4" 1" 2" 3" 4" 2" 3" 4"

MINIMUM OPENING 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 0.75" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"

MAXIMUM OPENING 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0" 1.25" 3.0" 4.5" 6.0" 3.0" 6.0" 8.0"

EXPOSED SURFACE 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" 2.0" 3.0" 4.0"

SPECIFY MODEL FWFC 100 FWFC 200 FWFC 300 FWFC 400 FWSC 200 FWSC 300 FWSC 400 FCFC 100 FCFC 200 FCFC 300 FCFC 400 FCSC 200 FCSC 300 FCSC 400

Model Data Corner Ceiling Covers

Model Data Ceiling Covers

Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

Use this cover for:

• Wall and ceiling applications to align with and match flush Thinline covers used in the floor.

• Suitable for most wall and ceiling finishes – frame configuration variable to suit selected finish.

• Where hygiene is important.

How it works:

Multi-directional flush single gasket wall and ceiling coveraccommodates both thermal and seismic movement.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

FLUSH

Thinline Wall & CEILING COVERS 1"-10"

FWFC

Continuous ExtrudedAluminum Frame

FeatheredJoint Cement

W

ES

Wall Covers

Corner Wall Covers

Ceiling Covers Corner Ceiling Covers

FWFC-MFWF

Wall Covers

FWS

FCF FCFC

FCS FCSC

ContinuousAluminum Frame

Continuous ExtrudedAluminum Frame

Feathered Joint Cement

Ribbed Gasket OffersBetter Movement

Gasket SuspendedCeilingW

ContinuousAluminum Frame

Feathered Joint Cement

W

WW

W

Continuous ExtrudedAluminum Frame

W

SuspendedCeiling

SuspendedCeiling

ContinuousAluminumFrame

SuspendedCeiling

W

ES ES ES

ES

ES ESES

Page 14: Ejc Catalog

26 27For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

FLUSH

Twinline Wall & CEILING COVERS 2"-UP

Use this cover for:

• Wall and ceiling applications to match flush Twinline covers used in the floor.

• Suitable for most wall and ceiling finishes.

How it works:

Dual gaskets expand and compress during movement, durable aluminum center plate can be painted to match wall finish and temporarily displaces during seismic events.

Model Data Wall Covers

Model Data Corner Wall Covers

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.0" 2.0" 3.0" 3.0" 3.0" 3.0" 3.0" 3.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0" 1.0"

MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 8.0" 12.0" 16.0" 20.0" 24.0" 28.0" 32.0"

EXPOSED SURFACE 6.5" 11.0" 13.0" 16.0" 19.0" 22.0" 25.0" 28.0" 11.13" 13.13" 15.13" 17.13" 19.13" 21.13" 23.13"

SPECIFY MODEL GTW 200 GTW 400 SGW 600 SGW 800 SGW1000 SGW1200 SGW1400 SGW1600 LAF 400 LAF 600 LAF 800 LAF1000 LAF1200 LAF1400 LAF1600

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.5" 3.0" 4.5" 5.5" 6.5" 7.5" 8.5" 9.5" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0" 2.0"

MAXIMUM OPENING 3.5" 6.0" 7.75" 10.25" 12.75" 15.25" 17.75" 20.25" 8.0" 12.0" 16.0" 20.0" 24.0" 28.0" 32.0"

EXPOSED SURFACE 4.25" 7.5" 9.5" 12.0" 14.5" 17.0" 19.5" 22.0" 7.62" 9.62" 11.62" 13.62" 15.62" 17.62" 19.62"

SPECIFY MODEL GTWC 200 GTWC 400 SGWC 600 SGWC 800 SGWC 1000 SGWC 1200 SGWC 1400 SGWC 1600 LAFC 400 LAFC 600 LAFC 800 LAFC 1000 LAFC 1200 LAFC 1400 LAFC 1600

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

LAFC

Shock Cord

ContinuousExtrudedAluminum Frame

Aluminum PanelDeflector

ES

Ceiling Cover

SGC

LAF

Wall Covers

Gasket Colors

AluminumPanel

Shock Cord Continuous ExtrudedAluminum Frame

Aluminum PanelDeflector

ES

Continuous FormedAluminum Frame

Turnbar

ES

Turnbar

National Archives II, MD

SGW

Gasket DisengagesTo Allow SeismicMovement

Continuous ExtrudedAluminum Frame

ES

Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

Corner Wall Covers

GTWC

GTW

Wall Covers

Gasket Continuous Extruded AluminumCover To Match Wall Finish

Continuous ExtrudedAluminum Frame

ES

ES

Continuous ExtrudedAluminum Center Plate

Gasket

Continuous ExtrudedAluminum Frame

Corner Wall Covers

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

AluminumHoney CombPanel

Page 15: Ejc Catalog

28 29For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Duracell Headquarters, CT

ALLWAY METAL

Wall & Ceiling COVERS 1"-4"

Use this cover for:

• Interior applications to match Allway metal floor covers.

• Standard aluminum covers supplied clear anodized, butKynar® paint and bronze or stainless top plates available.

How it works:

This wall cover’s free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish.

Corner Wall Covers Ceiling Covers

HCAFWCAFW

Wall Covers

HCW

Aluminum Anchor Clip

ESContinuous ExtrudedAluminum Center Plate

Continuous ExtrudedAluminum Cover Plate

W

ES

Dual DurometerPVC White Gasket

SuspendedAcoustical Ceiling(By Others)

ES

ES

Dual DurometerPVC White Gasket

W

W

W

ASMC ASM ES

Continuous ExtrudedWall Joint Cover SnapsInto Retaining Clip ForSimple Installation

2" Wide AluminumAnchor Clip

W

ES

W

Cover Edges GasketedFor Better Fit To Wall

JOINT WIDTH 1" 2" 3" 4" 1" 2" 3" 4" 1" 2" 3" 4"

MINIMUM OPENING 0.25" 0.5" 0.25" 1.0" 0.375" 0.375" 0.375" 0.375" 0.0" 0.0" 0.0" 0.0"

MAXIMUM OPENING 1.75" 3.5" 6.0" 7.0" 1.5" 3.0" 6.0" 6.0" 5.0" 6.0" 9.0" 10.0"

EXPOSED SURFACE 5.0" 7.75" 10.75" 11.75" 3.125" 4.625" 7.625" 7.625" 2.0" 3.0" 4.0" 5.0"

SPECIFY MODEL AFW 100 AFW 200 AFW 300 AFW 400 ASM 100 ASM 200 ASM 300 ASM 400 HC 100 HC 200 HC 300 HC 400

Model Data Wall Covers

Model Data Corner Wall Covers Model Data Corner Ceiling Covers

Model Data Ceiling Covers

JOINT WIDTH 1" 2" 3" 4" 1" 2" 3" 4" 1" 2" 3" 4"

MINIMUM OPENING 0.63" 1.25" 1.5" 2.5" 0.5" 0.5" 0.5" 0.5" 0.0" 0.0" 0.0" 0.0"

MAXIMUM OPENING 1.38" 2.75" 4.5" 5.5" 1.5" 3.0" 6.0" 6.0" 5.0" 6.0" 9.0" 10.0"

EXPOSED SURFACE 2.37" 4.25" 6.25" 7.25" 1.875" 3.375" 6.375" 6.375" 1.5" 2.5" 3.5" 4.5"

SPECIFY MODEL AFWC 100 AFWC 200 AFWC 300 AFWC 400 ASMC 100 ASMC 200 ASMC 300 ASMC 400 HCW 100 HCW 200 HCW 300 HCW 400

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Page 16: Ejc Catalog

30 31

JOINT WIDTH 2" 3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16" 1.0" 2.0" 3.0" 4.0" 6.0" 8.0"

MINIMUM OPENING 0.75" 0.75" 0.75" 0.75" 2.0" 2.0" 2.0" 2.0" 2.0" 6.0" 6.0" 6.0" .05" 1.0" 1.5" 2.0" 3.0" 4.0"

MAXIMUM OPENING 3.0" 4.5" 6.0" 7.5" 9.0" 10.5" 12.0" 13.5" 15.0" 18.0" 21.0" 24.0" 1.5" 3.0" 4.5" 6.0" 9.0" 12.0"

EXPOSED SURFACE 2.0" 3.0" 4.0" 5.0" 6.0" 7.0" 8.0" 9.0" 10.0" 12.0" 14.0" 16.0" 1.0" 2.0" 3.0" 4.0" 6.0" 8.0"

SPECIFY MODEL SF 200 SF 300 SF 400 SF 500 SF 600 SF 700 SF 800 SF 900 SF 1000 SF1200 SF 1400 SF 1600 VF 100 VF 200 VF300 VF 400 VF 600 VF 800

Model Data Wall Covers

Model Data Wall Covers

JOINT WIDTH 4" 5" 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16"

MINIMUM OPENING 0.75" 0.75" 2.0" 2.0" 2.0" 2.0" 2.0" 6.0" 6.0" 6.0" 6.0" 6.0" 6.0"

MAXIMUM OPENING 8.0" 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 22.0" 24.0" 26.0" 28.0" 30.0" 32.0"

EXPOSED SURFACE 4.0" 5.0" 6.0" 7.0" 8.0" 9.0" 10.0" 11.0" 12.0" 13.0" 14.0" 15.0" 16.0"

SPECIFY MODEL SC400 SC 500 SC 600 SC 700 SC 800 SC 900 SC 1000 SC 1100 SC 1200 SC 1300 SC 1400 SC 1500 SC 1600

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Ohio State University, OH

EXTERIOR WALL

Flexible Seals 2"-UP

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Wall Covers

Factory AppliedSilicone Face

ES

W

ES

W

Continuous ExtrudedSecondary Seal

VF

Wall Covers Wall Covers

SF-300

SC-400 SC-1200

W

W

W

TurnbarContinuous ExtrudedAluminum Frame

Continuous ExtrudedSantoprene Seal

Continuous ExtrudedAluminum Frame

Continuous ExtrudedSantoprene Seal

Cont. Extruded Alum.Center Mullion

Pantograph LoadSupport

Continuous ExtrudedAluminum Frame

ES

ES

SF-800C/S Supplied Adhesive

Impregnated CompressibleFoam BlockUse this cover for:

• Exterior vertical applications where weather protection is critical.

• Frames designed to attach to most external skin structures.

• 2" to 36" joint sizes with multi-directional movement.

• Factory welded transitions available.

• Four standard gasket colors (12 standard VF colors).

How it works:

Flush, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal.

SF-200 (typical cornercondition)

Note: Custom colors available. Call 800-233-8493.

Model VF Colors

Adobe Tan

Precast White

Dusty Rose

Limestone

Rustic Brick

Gray

Blue Spruce BlackCharcoalBronze

Natural Stone

SandstoneGasket Colors

Black White Gray Greige

Page 17: Ejc Catalog

JOINT WIDTH 8" 10" 12" 14" 16" 4" 8" 12" 16"

MINIMUM OPENING 4.0" 4.0" 4.0" 4.0" 4.0" 2.0" 2.0" 2.0" 2.0"

MAXIMUM OPENING 16.0" 20.0" 24.0" 28.0" 32.0" 8.0" 16.0" 23.0" 29.0"

EXPOSED SURFACE 17.31" 19.31" 21.31" 23.31" 25.31" 12.0" 18.0" 24.0" 30.0"

SPECIFY MODEL XLS 800 XLS 1000 XLS 1200 XLS 1400 XLS 1600 ESW 400 ESW 800 ESW 1200 ESW 1600

Model Data Wall Covers

JOINT WIDTH 8" 10" 12" 14" 16" 4" 8" 12" 16"

MINIMUM OPENING 4.0" 4.0" 4.0" 4.0" 4.0" 3.0" 5.0" 7.0" 9.0"

MAXIMUM OPENING 16.0" 20.0" 24.0" 28.0" 32.0" 7.5" 12.0" 17.5" 22.5"

EXPOSED SURFACE 13.0" 15.0" 17.0" 19.0" 21.0" 8.0" 13.0" 18.0" 23.0"

SPECIFY MODEL XLSC 800 XLSC 1000 XLSC 1200 XLSC 1400 XLSC 1600 ESC 400 ESC 800 ESC 1200 ESC 1600

Model Data Corner Wall Covers

3332 For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

de Young Museum, CA For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

SEISMIC

Exterior Wall COVERS 4"-UP

Use this cover for:

• Exterior seismic wall applications where cover concealment is desired within curtain wall finishes.

• Lightweight finish applications up to 9/16" thick (supplied by others).

• Zero maintenance required after an earthquake.

• Where high wind loads are expected.

How it works:

Flush exterior wall cover releases from wall on one side to provide full seismic movement. Cover returns to closed position after an event via counterweight system.

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

Wall Covers

ESW

XLS Expanded

Cycling

XLSXLS Contracted

XLSC ESC

Turnbar Vapor BarrierMoisture Seal

AluminumCover Plate

Wall Frame

Turnbar Vapor BarrierMoisture Seal

AluminumCover Plate

Wall PanelsField Installed,and Suppliedby Others

SS Hinge

ES

Extruded AluminumFrame

Strike Plate

Magnet

Ladder SystemAccepts Wide Rangeof Mounting Systemsand Panels

W

W

Wall PanelsField Installed,and Suppliedby Others

S.S. Hinge

ES

WeldedAluminumTube Frame

ControlAssemblyFrame

HingeFrame

Wall Substrate

W

Wall PanelsField Installed,and Suppliedby Others

Wall PanelsField Installed,and Suppliedby Others

ES

W

Page 18: Ejc Catalog

34 35For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

Round Valley Office Complex, NJ

Roof Covers 2"-UP

Use this cover for:

• Applications in built-up, flat roofs.

• Joint sizes from 2" to 36"

• Multi-directional movement requirements.

How it works:

For metal roof covers, aluminum frames create a seal tothe underside of sliding metal cover plates. For flexibleroof joint covers, bellows material expands and contractsfor multi-directional movement.

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.0" 1.0" 1.0" 1.0" 0.0" 0.0" 0.0" 0.0" 0.5" 0.5" 0.5" 0.5" 0.5" 0.5" 0.5"

MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 8.0" 11.5" 13.5" 17.5" 20.5" 21.5" 25.0"

EXPOSED SURFACE 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 22.0" 24.0" 12.0" 15.0" 18.0" 21.0" 24.0" 27.0" 30.0"

SPECIFY MODEL BRJ 200 BRJ 400 BRJ 600 BRJ 800 BRJ 1000 BRJ 1200 BRJ 1400 BRJ 1600 SRJ 400 SRJ 600 SRJ 800 SRJ 1000 SRJ 1200 SRJ1400 SRJ 1600

Model Data Roof Covers

Model Data Roof to Wall Covers

JOINT WIDTH 2" 4" 6" 8" 10" 12" 14" 16" 4" 6" 8" 10" 12" 14" 16"

MINIMUM OPENING 1.0" 1.0" 1.0" 1.0" 1.0" 0.0" 0.0" 0.0" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5"

MAXIMUM OPENING 3.0" 6.0" 9.0" 12.0" 15.0" 18.0" 21.0" 24.0" 6.5" 8.5" 11.0" 13.5" 16.0" 18.5" 21.0"

EXPOSED SURFACE 6.0" 8.0" 10.0" 12.0" 14.0" 16.0" 18.0" 20.0" 8.0" 10.5" 13.0" 15.5" 18.0" 20.5" 23.0"

SPECIFY MODEL BRJW200 BRJW 400 BRJW 600 BRJW 800 BRJW 1000 BRJW 1200 BRJW 1400 BRJW 1600 SRJW 400 SRJW 600 SRJW 800 SRJW 1000 SRJW 1200 SRJW 1400 SRJW 1600

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

Roof To Wall Covers Specialty Roof Joint CoversHigh Movement and High Wind Loads

Gyrometric Cover

SRJWSRJ

BRJ

Roof To Roof Covers

Parapet Transitions

BRJW

WW

Turnbar

AluminumCover Plate

Vapor Barrier

ExtrudedAluminumFrame

Moisture Seal

W

ExtrudedSecondary Seal(Optional)

ContinuousMetal Retainer

Furnace Bellows

Closed CellFoam

AluminumRetainer

W

FactoryFabricated EndTransition TucksUp BehindVertical Seal

Factory Fabricated BaseClosure For Vertical Seal

Composite Design toMeet Project Wind Loadsand Movement Criteria

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Page 19: Ejc Catalog

36 37

JOINT WIDTH 4" 6" 8" 6" 8" 10" 12" 14" 16" 4" 6" 8"

MINIMUM OPENING 2.0" 3.0" 4.0" 0.0" 0.0" 0.0" 0.0" 0.0" 0.0" 1.25" 1.25" 1.25"

MAXIMUM OPENING 6.0" 9.0" 12.0" 11.0" 13.0" 16.0" 19.0" 22.0" 25.0" 5.25" 8.0" 10.25"

EXPOSED SURFACE 17.0" 22.0" 26.0" 24.5" 26.5" 29.5" 32.25" 35.25" 38.25" 7.63" 11.13" 14.13"

SPECIFY MODEL KB 400 KB 600 KB 800 PTC 600 PTC 800 PTC 1000 PTC 1200 PTC 1400 PTC 1600 KBW400 KBW600 KBW800

Model Data Floor to Floor Covers Model Data Floor to Wall Covers

Model Data Floor to Floor Covers

JOINT WIDTH 2.0" 3.0" 4.0" 1.0" 2.0" 3.0" 4.0" .87" 1.68" 2.56" 3.43"

MINIMUM OPENING 1.0" 1.5" 2.0" 0.6" 1.13" 1.5" 2.0" 0.43" .87" 1.37" 1.81"

MAXIMUM OPENING 3.0" 4.5" 6.0" 1.5" 3.0" 4.5" 6.0" 1.25" 2.5" 3.75" 5.0"

EXPOSED SURFACE 9.0" 10.0" 11.0" 1.0" 2.0" 3.0" 4.0" 0.87" 1.68" 2.56" 3.43"

SPECIFY MODEL ZB200 ZB300 ZB400 HB100 HB200 HB300 HB400 HBF100 HBF200 HBF300 HBF400

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

For odd and larger sized joints, call (800) 233-8499 or visit www.c-sgroup.com

PARKING

Covers & Seals 1"-16"

Use this cover for:

• Seismic applications in parking and other areas with vehicular access.

• Available in standard or HS-20 heavy duty loading.

• New Cast-In-Place Model Available for post-tensioned slab applications.

How it works:

For a complete description call (800) 233-8493 and requesta parking cover catalog or go to www.c-sgroup.com

Annapolis City Marina Parking, MD

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

JOINT WIDTH

MINIMUM OPENING

MAXIMUM OPENING

EXPOSED SURFACE

SPECIFY MODEL

ZB

KBC

W

WW

SealantOne-Piece EPDM Seal Bonded inan Epoxy Bed for Fast Installation

For Cast-In PlaceApplications Vapor Barrier

PTCW

CompressionSpring

ElastomericConcrete

ExtrudedAluminumFrame

AluminumCover Plate

Leveling Grout (By Others)

Extruded AluminumRotational Frame

Vapor Barrier

PDA

HBFW

Installedwith EpoxyAdhesive

Neoprene Seal

HBW

“Hybrid” Compression SealIncorporating Built In Reservoirsfor Epoxy Adhesive

No InflationNeeded

KBW For Joint Sizes up to 9"

with 50% Movement

RemovableVapor Barrier

Turnbar Housing PreventsShearing of Bolts

Aluminum Top Cap(Stainless Steel Optional)

CompressionSeal

ExtrudedAluminum Side Frame

ESElastomericConcrete

Page 20: Ejc Catalog

When an expansion or seismic joint passes through afire-rated structure it is necessary to maintain the fire

integrity of that structure. Maintaining the integrity of a

2" wide joint is quite simple; however, a joint designed

for seismic movement up to 24 inches becomes a more

difficult proposition. In general, the wider the joint, the more complex the fire barrier. Most

manufacturers use the same barrier design for all joint

sizes. C/S has simplified our fire barrier for small joint

sizes for easy installation and to maximize cost

effectiveness (see Reflex). Floor applications are relatively simple configurations regardless of joint size

unless lateral shear is required. Walls, on the other hand,

can be more complex. All C/S fire barriers require only

one barrier in the wall and require that the studs be

wrapped with drywall to maintain full integrity.

(Includes shaft walls) Variations in wall configurationsand finishes, as well as transitions between adjacent fire barriers, make it critical to consult the manufacturer

concerning typical applications. C/S has a technical

expert available to assist you in detailing these

applications. Since 1996 building codes require firebarriers to limit the passing of heat and flame for 2, 3

and sometimes 4 hours, as well as accommodating the

dynamic movement for which the joint was designed.

ASTM E 1966 and UL 2079 specify criteria for “cycling”

a fire barrier 500 times prior to fire testing. C/S tests

all of its fire barriers at Underwriters Laboratories

(UL) because they represent the most stringent

and universally accepted testing authority.

“LS” designation indicates a special adaptation of the floor fire barrier to accommodate Lateral Shear movement.FB-97 wall fire barriers naturally provide lateral shear movement.

Reflex® 1"- 4" Stainless steel foil drape with block insulation affords maximum economy in materialand installation. Wall barriers limited to 1” - 4” joints and require no stainless foil.

NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL

1 RFX-1F FF-D-0044 RFX-1W (GYP.) WW-D-0048 RFX-1W(CONC) WW-D-0050

RFX-1X FF-D-0044 RFX-1W (1 HR GYP.) WW-D-0059 RFX-1W(1 HR CONC.) WW-D-0060

2 RFX-2F FF-D-0045 RFX-2W (GYP.) WW-D-0049 RFX-2W(CONC) WW-D-0051

RFX-2F FF-D-0045 RFX-2W (1 HR GYP.) WW-D-0061 RFX-2W(1 HR CONC.) WW-D-0062

3 RFX-3F FF-D-1055

4 RFX-4F FF-D-1065FOR WALL APPLICATIONS OVER 2" PLEASE SEE MULTIFLEX OFFERING

Multiflex® 3"-12"“Sandwich” assembly of layers of stainless steel foil and insulation contained in a stainless steelmesh. Standard barrier allows up to 50% lateral shear in floor applications.

FB97 13"-UpMultiple drape configurations of stainless foil and insulation utilizing air pockets for additionalinsulation performance. Sliding frame available for 100% lateral shear applications in floors.

NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL

13-24 FB97-13-24 FF-D-3005 FB97-13-24(GYP) WW-D-3007 FB97-13-24(CONC) WW-D-3008

25-36 FB97-25-36 FF-D-4001 NA NA NA NA

13-24 FB97-13(LS)-24(LS) FF-D-3006 NA NA NA NA

25-36 FB97-25(LS)-36(LS) FF-D-4002 NA NA NA NA

NOMINAL C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBER C/S MODEL C/S UL NUMBERJOINT WIDTH FLOORS FLOOR GYPSUM WALL GYPSUM WALL MASONRY WALL MASONRY WALL

3-6 MFX-3F-6F FF-D-1066 MFX-3W-6W(GYP) WW-D-1056 MFX-3W-6W(CONC) WW-D-1057

7-12 MFX-7F-12F FF-D-2009 MFX-7W-12W(GYP) WW-D-2011 MFX-7W-12W(CONC) WW-D-2012

UL TestingAll C/S Fire Barriers are tested rigorously at Underwriters Laboratories,including UL 2079 “Cycling” Tests.

NO MATTER WHAT JOINT COVER YOU NEED,

We’ve got the right fire barrier.CHOOSE THE F IRE BARRIER THAT BEST SUITS YOUR PROJECT.

Page 21: Ejc Catalog

For the nearest C/S representative, or literature and samples, call toll free 800-233-8493 in U.S.A. and 888-895-8955 in Canada, or visit www.c-sgroup.com

©Copyright 2009 Construction Specialties, Inc.

Construction Specialties, Inc. reserves the right to make design changes or to withdraw any design without notice. Printed in U.S.A. Series 10

The C/S Family of Products

For more than 60 years, Construction Specialties has been a leader in architectural specialty products, including: Acrovyn® Wall and Door Protection, Pedisystems® EntranceFlooring, Expansion Joint Covers, Cubicle Track and Curtains, Smoke and Explosion Venting Systems, Architectural Grilles,Architectural Louvers and Sun Controls.

We have operations throughout the world and can provide C/S Products virtually anywhere. For a complete list of our international locations, visit www.c-sgroup.com.

6696 State Route 405, Muncy, Pennsylvania 17756 U.S.A., 570-546-5941

895 Lakefront Promenade, Mississauga, Ontario L5E 2C2 Canada, 905-274-3611

www.c-sgroup.com