Change in Inspection Plan
Whenever MIC is deleted or added, there is need of changing the inspection plan. Changing Inspection plan is an engineering change. Hence any change in inspection plan must be done with an ECR (Engineering Change Request)
Procedure of change in inspection plan
Step 1
Create an ECR
T Code: CC01
Run T Code CC01 to get the below shown screen
Select ECR Select “Without Release Key” In function section Select 310 Change Type and then press enter to get the next screen.
Select ECR
Click On F4 Help Icon and select 310 change type
Select without Release key
Change in Inspection Plan
Enter the description of ECR Enter valid from date Enter reason for change Set status as active i.e. 01
After filling the above data click on object Types to get the next screen.
Enter description for engineering change
Enter Valid From date
Enter reason for change
Set status as Active
Change in Inspection Plan
Click on checkbox of task list in ACTV and object columns
After clicking the checkbox select Objects to get the next screen
Select task list
Click on objects
Change in Inspection Plan
Enter task List type “Q” for change in inspection plan Write the inspection plan number in group section Add description in description column Enter change type as 001
After filling all the required fields click on Header to get the initial screen.
Enter Task list type
Enter the Group which is to be
changed Write Description
Enter Change type
Header
Change in Inspection Plan
1. Click on SET STATUS icon to get the POP UP2. Then click on the CHECK ECR icon and save the page to get the change number. Note down the
change number for future reference
Now it is needed to change the object status for further proceedings
Now we have to change ECR
1. Click on Set status to get the pop up
2. Click on Check
Change in Inspection Plan
Run T code CC02 to get the below given screen
Enter change number and press enter to get the next screen
Click on Objects to get the next screen
Enter Change Number
Click on Objects
Select the Row and click on DETAILS to get a pop up
Change in Inspection Plan
After clicking on Set Status, a pop up will emerge. Now click on Change possible icon and click on Continue.
After completing this page, go to header by clicking on Header icon to get the next screen.
1. Click on Set Status
2. Click on Header
2. Click on Change Possible
Change in Inspection Plan
Click on ECR Checked Icon to get the change in the pop up as shown below.
Click on SET STATUS Icon to get the pop up
Click on ECR Checked Icon in Pop up
Change in Inspection Plan
After Clicking on Convert ECR, click on Continue and save the file and Note down the Change Number.
Now this change number is to be mentioned in the Master Inspection characteristics template whenever there is any change in the existing inspection plan.
Click on APPROVE ECR
Click On Convert ECR