e 76590 lvh-c en 2014-06-16[2]

Upload: azmi-ahmad

Post on 01-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/9/2019 E 76590 LVH-C en 2014-06-16[2]

    1/5

     

    E 76590 LVH-CD en 2014-06-16.doc D 7.659.0 1 / 5

    Description The LowViscosity- Housing CoalescerLVH-C is mainly used for the dewateringof diesel. It is especially suitable forapplications with large amounts of waterthat need to be removed in just a single

    pass.The Optimicron®-Coalescer- andseparator elements ensure that a highvolume of water will be separated within just a single pass.

     Available in various sizes, the housingscan be optimally integrated into new orexisting systems.

    The filters are designed according to the AD2000 German rules and regulations forpressure vessels or according to ASME.

    Applications 

      Diesel dewatering of large flow rates.

    The advantages to you   Excellent filtration performance in a

    single pass

      Low pressure loss due to innovativeelement technology

      Easy to service thanks to intelligentelement design

      Easy to adapt to filter housings forthe removal of fine particles in diesel. 

    LowViscosity Housing- Coalescer

    LVH-C 

    Technical specifications 

    General data

    Material housing Stainless steel or Carbon steel

    Max. operating pressure 10 bar

    INLET connector DN 50 … 300

    OUTLET connector DN 50 … 300

    Operating temperature 50 °C maximum

     Ambient temperature 50 °C

    Material of sealings FKM (FPM, Viton®)

    Filter elements

    Filter elements used Optimicron® Diesel

  • 8/9/2019 E 76590 LVH-C en 2014-06-16[2]

    2/5

     

    E 76590 LVH-CD en 2014-06-16.doc D 7.659.0 2 / 5

    Model code

    LVH – C D – 4 40 – E V – B V – F D32 /-ZA

    Type

    LVH = LowViscosity Housing

    FunctionC = Coalescence

    Operating fluidD = Diesel

    Filter Size4 = 4 Coalescing elements + 3 Seperation elements6 = 6 Coalescing elements + 4 Seperation elements9 = 9 Coalescing elements + 6 Seperation elements

    Filter element length

    40 = 40“

    Housing materialE = Stainless steelN = Carbon steel

    VersionV = vertical

    Pressure rangeB = 10 bar

    Hydraulic connectionL = DIN DN 50

    T = DIN DN 100V = DIN DN 150W = DIN DN 200Y = DIN DN 300

    Material of sealingsF = FKM (FPM, Viton

    ®)

    Clogging indicatorC12 = Differential pressure indicator, electricalD17 = Differential pressure indicator, visual/electrical (230V)D18 = Differential pressure indicator, visual/electrical (24V)D32 = Differential pressure indicator, visual/electrical (PVL2GW.0/-V-113) D33 = Differential pressure indicator, visual/electrical (PVL2GW.0/-111-16) 

    Z = without Clogging Indicator

    Supplementary detailsZA = Certification (ASME certification)

    Filter calculationFilter Size Maximum

    flow rate

    Number of

    coalescing

    elements

    Number of

    seperations

    elements

    Weight

    when

    empty(kg)

    Housing

    volume

    (Liter)

    LVH-CD-4 40 800 l/min 4 pcs. 3 pcs. ≈ 500 ≈ 470

    LVH-CD-6 40 1200 l/min 6 pcs. 4 pcs. ≈ 580 ≈ 670

    LVH-CD-9 40 1800 l/min 9 pcs. 6 pcs. ≈ 780 ≈ 1225

    Scope of delivery  LVH-CD (without filter elements)

      Installation and MaintenanceInstructions

    Filter elements must be orderedseparately and installed before initialoperation on site.

    AccessoriesDesignation Part no.:

     Automatic Drain Kit,consist. of:- Level indicator- Electric control- Drain valve

    xxxxxxxx

    Coalescing element 40"Designation Part no.:

    N42ON-DCZ-CA60F 3910257*) on request

    Separation element 30"Designation Part no.:

    N32ON-DSZ-SA80F 3910259*) on request

    Hydraulic diagram

    801

    802

    804

    803

    600

    100

    808

    809

     

    Item Designation

    100 Filter housing

    600 Clogging indicator (Option)

    801 Inlet (IN)

    802 Outlet (OUT)

    803 Drain, clean side (DRAIN)

    804 Drain, contaminated side(DRAIN)

    808 Measurement point (IN)

    809 Measurement point (OUT)

  • 8/9/2019 E 76590 LVH-C en 2014-06-16[2]

    3/5

     

    E 76590 LVH-CD en 2014-06-16.doc D 7.659.0 3 / 5

    Dimensions LVH-CD-4 40 

     All dimensions in mm.

    Item Designation

    9 Type label

    100 Filter housing

    600 clogging indicator (optional)

    801 Inlet (IN)

    802 Outlet (OUT)

    803 Drain, clean side (DRAIN)

    804 Drain, contaminated side (DRAIN)

    805 Cover lifting device

    806 Eyelets for transportation / Lifting eyes

    808 Measurement point (IN)809 Measurement point (OUT)

    810 Air bleed

    811 Outlet Water

    812 Drain Housing

    815 Maintenance space for changing the filter elements

  • 8/9/2019 E 76590 LVH-C en 2014-06-16[2]

    4/5

     

    E 76590 LVH-CD en 2014-06-16.doc D 7.659.0 4 / 5

    Dimensions LVH-CD-6 40 

     All dimensions in mm.

    Item Designation

    9 Type label

    100 Filter housing

    600 clogging indicator (optional)

    801 Inlet (IN)

    802 Outlet (OUT)

    803 Drain, clean side (DRAIN)

    804 Drain, contaminated side (DRAIN)

    805 Cover lifting device

    806 Eyelets for transportation / Lifting eyes

    808 Measurement point (IN)

    809 Measurement point (OUT)

    810 Air bleed

    811 Outlet Water

    812 Drain Housing

    815 Maintenance space for changing the filter elements

  • 8/9/2019 E 76590 LVH-C en 2014-06-16[2]

    5/5

     

    E 76590 LVH-CD en 2014-06-16.doc D 7.659.0 5 / 5

    Dimensions LVH-CD-9 40 

     All dimensions in mm.

    Item Designation

    9 Type label100 Filter housing

    600 clogging indicator (optional)

    801 Inlet (IN)

    802 Outlet (OUT)

    803 Drain, clean side (DRAIN)

    804 Drain, contaminated side (DRAIN)

    805 Cover lifting device

    806 Eyelets for transportation / Lifting eyes

    808 Measurement point (IN)

    809 Measurement point (OUT)

    810 Air bleed

    811 Outlet Water

    812 Drain Housing

    815 Maintenance space for changing the filter elements

    Note:The information in this brochure relates tothe operating conditions and applicationsdescribed.In the event of deviating applicationsand/or operating conditions, pleasecontact the respective HYDAC departmentconcerned.Subject to technical modifications. 

    HYDAC FILTER SYSTEMS GMBHIndustriestraße66280 Sulzbach / SaarGermany

    Telephone:+49 (0)6897 / 509-01Fax: +49 (0)6897 / 509-9046Internet: www.hydac.com E-mail: [email protected]

    http://www.hydac.com/http://www.hydac.com/