dx2002 analogue out

Upload: do-huu-khuong

Post on 28-Feb-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/25/2019 DX2002 Analogue Out

    1/2

    control panel cutout: 91 x 44 mmMade in Germany

    Product characteristics

    Digital display

    FX 360

    Multi-functional display and evaluation system

    Can be used for example as:

    frequency meter/tachometer

    processing time/baking time display

    industrial timer

    position and event counter

    display of speed measured from elapsed time

    Analogue output

    0/4...20 mA; 0...10 V

    Application

    universal evaluation and display for all physical units which can be derived from

    pulse sequences

    Application

    Electrical data

    115/230 AC (50...60 Hz) / 24 DCOperating voltage [V]

    AC 12.5; DC -33/+58Voltage tolerance [%]

    120 (18 V); 95 (24 V); 80 (30 V)Current consumption [mA]

    7.5Power consumption [VA]

    24 DC; 15 %; 150 mASensor supply [V]

    Inputs

    3 (pnp; npn/NAMUR); short-circuit protection

    Current consumption: 5.1 mA at 24 V level (Ri = 4.7 kOhm)

    Input level HTL: Low 0...3.5 V; High 9...35 V

    Input frequency (max): A/B = 25 kHz (ti = 0.02 ms); C = 1 kHz (ti = 1 ms)

    Accuracy of the frequency measuring: 1 ppm; 1 digit

    Inputs

    Outputs

    Switching output

    DX2002Evaluation systems, power suppliesDISPLAY/FX360/ANALOG OUT

  • 7/25/2019 DX2002 Analogue Out

    2/2

    0/4...20 mA; 10 V; scaleable

    Resolution: 14 bit (+ sign)

    Accuracy: 1 %

    Response time: 300 ms

    Burden: 300

    Analogue output

    Environment

    0...45Ambient temperature [C]

    -25...75Storage temperature [C]

    IP 65 / IP 20; on the frontProtection housing / terminals

    Tests / approvals

    EMC EN 50081-1

    EN 61000-6-2

    Safety classification

    80MTTF [a]

    Mechanical data

    Noryl UL94-V-0Housing materials

    0.581Weight [kg]

    Displays / operating elements

    7-segment LED display; high efficiency orange; 15 mm; 6 positionsFunction display LED

    Electrical connection

    10 screw terminals...1.5 mm (DC and inputs); 4 screw terminals...2.5 mm (AC

    supply)

    Connection

    Wiring

    1: DC supply voltage

    2: signal inputs A/B; reset C

    and DC sensor supply

    3: analogue outputs

    4: AC supply voltage

    Remarks

    1Pack quantity [piece]ifm electronic gmbh Friedrichstrae 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB DX2002 23.01.2004

    DX2002Evaluation systems, power suppliesDISPLAY/FX360/ANALOG OUT