dx error messages

559
Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 05 General Error Messages of System DN987378 Issue 24-0

Upload: markuskrasus

Post on 28-Oct-2014

466 views

Category:

Documents


6 download

DESCRIPTION

General Error Messages of System

TRANSCRIPT

Page 1: DX Error Messages

Nokia Siemens Networks GSM/EDGE BSS, rel. RG10(BSS), operating documentation, issue 05

General Error Messages of System

DN987378

Issue 24-0

Page 2: DX Error Messages

2 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e099

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2010. All rights reserved

f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

Therefore, only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Page 3: DX Error Messages

DN987378Issue 24-0

3

General Error Messages of System

Id:0900d8058077e099

Table of ContentsThis document has 559 pages.

1 General error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2 DX error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.1 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Page 4: DX Error Messages

4 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e099

Page 5: DX Error Messages

DN987378Issue 24-0

5

General Error Messages of System General error messages

Id:0900d805803e33d7

1 General error messagesThe general error messages are listed here in numerical order.

During an MML session, the user can see the explanation of an error that has occurred, together with instructions (if any) how to proceed, by pressing the character combination CTRL-7. In addition, the user can search for the explanation of an error message by means of the service terminal extension MRSTRE.

As this list contains the general execution error messages of all applications, it is possible that it will also include messages that do not belong to the configuration of a particular customer.

Page 6: DX Error Messages

6 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

2 DX error messages

2.1 Error messages0 SUCCESS

The operation succeeded completely.

1 NO SUCH FILE

The file does not exist.

2 FILE READ PROTECTED

The file is read protected.

3 OFFSET OUT OF FILE

The offset points out of the file.

4 OFFSET OUT OF RECORD

The offset points out of the record.

5 RECORD NUMBER OUT OF FILE

The number of the record is equal to or greater than the number of records in the file.

6 SUBRECORD NUMBER OUT OF RECORD

The number of the subrecord is equal to or greater than the number of subrecords in the file.

7 SEARCH KEY NOT FOUND

The search key is not found in the file.

8 FILE ALREADY EXISTS

The file already exists.

9 NOT IMPLEMENTED

The feature has not been implemented.

10 INCORRECT FILE HANDLE

The file handle is incorrect.

11 INCORRECT FILE TYPE

The type of the file is unknown, or it does not fit in the situation.

12 FILE HAS NO BITMAP

The file has no bitmap.

13 POINTER TO FILE DEFINITION STRUCTURE IS NULL

The pointer to the structure defining the characteristics of a file is null.

14 INCORRECT FILE DEFINITION STRUCTURE

The structure defining the characteristics of a file is incorrect.

15 INCORRECT ACCESS MODE

The access mode is forbidden or unknown.

16 FILE CATALOG FULL

The file catalog is full.

Page 7: DX Error Messages

DN987378Issue 24-0

7

General Error Messages of System DX error messages

Id:0900d8058077e097

17 PROCESS LDT FULL

The LDT (local description table) of the process is full.

18 MEMORY ALLOCATION ERROR

An error has occurred in the allocation of memory space.

19 FILE WRITE PROTECTED

The file is write protected.

20 INCORRECT FILE BLOCK NUMBER

The number of the file block is incorrect.

21 NO BLOCK CHECK SUM IN FILE

The file has no block-specific check sums.

22 NULL POINTER TO PARAMETER

The pointer to the parameter is null.

23 ARRAY REALLOCATION ERROR

An error has occurred in the array reallocation.

24 RECORD IS FREE

The record is free.

25 RECORD IS NOT FREE

The record is not free.

26 END OF FILE CATALOG

The file catalog has ended.

27 CHECK SUM CALCULATION FAILURE

The calculation of the check sum failed (file was updated during the cal-culation).

28 PCMCON GSW ERROR

The PCMCON file of the group switch is incorrect.

29 FILE DISTRIBUTION TIME-OUT

The time limit of file distribution has expired.

30 FILE DISTRIBUTION ERROR

An error has occurred in file distribution.

31 UNIT TYPE ACCESS ERROR

An error has occurred in conversions between the unit type, logical address and message bus address.

32 FLOPPY DISK CONTROLLER BUSY

The floppy disk controller has not returned to its original state after the previous disk operation. The floppy disk controller is faulty. Restart the EDISKD program block. Replace the DMADI plug-in unit.

33 FLOPPY DISK CONTROLLER IN RESULT PHASE

The floppy disk controller is in result phase. A new command is given when the previous command is still in result phase. There is a distur-bance in the EDISKD program block or the floppy disk controller is

Page 8: DX Error Messages

8 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

faulty. Restart the program block EDISKD. Replace the DMADI plug-in unit.

34 FLOPPY DISK CONTROLLER IN COMMAND PHASE

The floppy disk controller is in the command phase. The floppy disk con-troller waits for a new command while an attempt is made to read the result of the previous command from it. There is a disturbance in the EDISKD or the floppy disk controller is faulty. Initialize the floppy disk controller again. Replace the DMADI plug-in unit.

35 EQUIPMENT CHECK ERROR

The disk drive has given an error signal or the 0 cylinder is not reached in the recalibration command after 77 step pulses. The disk drive or the floppy disk controller is faulty. Replace the disk drive. Replace the DMADI plug-in unit.

36 DRIVE NOT READY

The disk drive is not capable of executing a new disk operation. The operator tries to read the empty side of a single-sided disk or write on an empty side of a single-sided disk. The disk type is not correct, the disk does not exist, the door of the disk drive is open, there is no power in the disk drive, the disk drive does not exist, the disk drive is faulty or the floppy disk controller is faulty. Check the disk. Close the door of the disk drive. Check the disk drive and change it if necessary. Replace the DMADI plug-in unit.

37 RECALIBRATE ERROR

The transfer of the read/write head of the disk drive to the 0 track has failed. Replace the disk drive. Replace the DMADI plug-in unit.

38 SEEK ERROR

The search for a track or a sector has failed. The disk drive or the floppy disk controller is faulty. Replace the disk drive. Replace the DMADI plug-in unit.

39 END OF TRACK ERROR

The floppy disk tries to direct a command to a sector whose number is higher than that of the last sector of the track. There is a disturbance in the EDISKD program block or the floppy disk controller is faulty. Restart the EDISKD process. Replace the DMADI plug-in unit.

40 CRC ERROR IN DATA

There is a CRC error in the data field of the sector. The disk is faulty. Replace the disk.

41 CRC ERROR IN ID

There is a CRC error in the ID field of the sector. The disk is faulty. Replace the disk.

42 LATE DMA

The DMA controller does not receive permission for DMA transfer in time. The DMA controller is faulty or the administration logic of the bus is faulty. Replace the DMADI plug-in unit. Replace the CPU386 plug-in unit.

Page 9: DX Error Messages

DN987378Issue 24-0

9

General Error Messages of System DX error messages

Id:0900d8058077e097

43 SECTOR NOT FOUND

The floppy disk controller does not find the sector required. The disk is faulty or the floppy disk controller is faulty. Replace the disk. Replace the DMADI plug-in unit.

44 DISK WRITE PROTECTED

The disk is write protected. Remove write protection.

45 MISSING DATA ADDRESS MARK

The floppy disk controller does not find the data address mark on the required track. The disk or the floppy disk controller is faulty. Replace the disk. Replace the DMADI plug-in unit.

46 MISSING ID ADDRESS MARK

The floppy disk controller does not find the ID address mark on the required track. The disk or the floppy disk controller is faulty. Replace the disk. Replace the DMADI plug-in unit.

47 CONTROL MARK

A deleted data address mark has been read during a reading operation. The disk is faulty. Replace the disk.

48 CYLINDER ADDRESS ERROR

The cylinder address of the ID field of the sector differs from the current cylinder address maintained by the floppy disk controller. There is a dis-turbance in the program block EDISKD, the disk is faulty or the floppy disk controller is faulty. Initialize the floppy disk controller again. Replace the disk. Replace the DMADI plug-in unit.

49 BAD SECTOR

Floppy disk: The cylinder address of the ID field of the sector is 0FFH. The disk is faulty. Replace the disk. Winchester: The disk operation has been directed to a track which has been marked bad.

50 INCORRECT TASK

Incorrect command. The program block EDISKD does not recognize the task given. The application program is faulty. Check the application program.

51 NO EQUIPMENT

There is no equipment. There are no disk drives connected to the DMADI plug-in unit, or the cable between the DMADI and the disk drive has been accidentally disconnected. Connect the cable.

52 INCORRECT PARAMETER IN TASK

The parameter is incorrect. One of the parameters of the parameter block is incorrect. The application program is incorrect. Check the appli-cation program.

53 END OF DISK FOUND

The last sector of the disk has been reached. An attempt is made to read from the disk (absolute reading) or to write onto the disk (absolute writing) past the end of the disk. The reading or writing is ended in the last sector. An attempt is made to write outside the memory of the disk.

Page 10: DX Error Messages

10 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

54 COMMAND NOT ALLOWED ON OLD FORMAT DISK

The command is not allowed on the disk of the old format. Do not give this command.

55 FORMAT ERROR

Floppy disk: The formatting of the disk has failed. The disk is faulty. Replace the disk. Winchester: The read/write head of the disk drive stays on the track on which the formatting has failed. Mark the track bad and format the alternative track.

56 NO SUCH FILE

The file specified by the parameter block is not found on the disk. The disk is incorrect or the application program is faulty. Replace the disk. Check the application program.

57 LABEL IS THE ONLY ONE

An attempt has been made to delete the only label of the disk file.

58 FILE WRITE PROTECTED

The file is write protected.

59 FILE ALREADY UNPROTECTED

The file is already unprotected through another label.

60 FILE ALREADY EXISTS

The file already exists.

61 END OF DATA FOUND

The last data sector of the file has been reached. An attempt is made to read the file past the end of the data. The reading is ended in the last data sector.

62 NO DATA TO READ

There is no data to read. The file is empty or the read pointer of the parameter block points past the end sector of the file data.

63 END OF FILE FOUND

The last sector of the file has been reached. An attempt is made to write past the end of the file. The writing is ended in the last sector.

64 FILE FULL

The file is full.

65 FILE TOO BIG

An attempt has been made to create a file which requires too much memory space. Pack the disk. Reduce the memory reservation of the file.

66 DISK FULL

The disk is full. All file labels of the disk are in use.

67 TOO MANY CRC ERRORS

The CRC counter of the disk has reached the maximum value. Replace the disk.

68 DMA TERMINATION ERROR

Page 11: DX Error Messages

DN987378Issue 24-0

11

General Error Messages of System DX error messages

Id:0900d8058077e097

The DMA transfer has been shorter than expected. Replace the DMADI plug-in unit.

69 TIME-OUT ERROR

The device has not responded within the given time. Carry out periodic maintenance and replace the used media if necessary. If the problem re-occurs, check the device, used media, cabling and controller.

70 INCORRECT COMMAND

The command code of the parameter block is unknown.

71 WRITE BLOCK TOO SHORT

The length of the block to be written is shorter than 4, and blocks shorter than 4 cannot be written on the tape. Load the MML and try again.

72 MULTIFILE NOT ALLOWED

An attempt has been made to open a file on a one-file tape with a mul-tifile opening command or quick file opening command. When neces-sary, change the tape type into a one-file tape and try again.

73 TRACK WRITE PROTECTED

Reel-to-reel tape unit (MTU) is write protected. Remove the protection unless there is a reason for it.

74 ONE FILE TAPE

An attempt has been made to direct to a one-file tape one of the follow-ing commands which can be directed only to multifile tapes: premark tape, close file quickly, close multifile, search for HDR1 block or search for file. Replace the tape with a multifile tape and give the command again.

75 CORRECTED ERROR

The formatter has detected an error in connection with a reading or writing operation. The error has been corrected and data can be read from the tape.

76 TAPE MARK READ

The block read was a tape mark. Repeat the MML command. If the error occurs again, clean the read head of the drive and change the tape reel.

77 VERIFY ERROR

The data has not been written on the tape. The fault is either in the reel-to-reel tape unit or in the RAM. Locate and replace the faulty unit.

78 CRC ERROR

Despite repeated attempts writing fails due to a fault in the tape or in the read head. Clean the read head of the reel-to-reel tape unit or replace the tape with a new one.

79 LATE DMA

The DMA circuit of the DMADI has not transferred data between the MTU and the RAM. The fault is either in the TAPI, DMADI or CPU386 plug-in units. Highest probability is that the fault is in the DMADI. Replace the faulty unit.

Page 12: DX Error Messages

12 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

80 DRIVE NOT READY

The reel-to-reel tape unit is not ready to receive commands. There is a hardware fault in the drive. Try again in 3-4 minutes.

81 FORMATTER BUSY

The reel-to-reel tape unit is executing a command. A new command has been given before the previous one has been acknowledged. The oper-ating system is faulty. Locate the fault, initialize the TAPEDR program block if necessary.

82 ACCESSED DRIVE OFF LINE

The reel-to-reel tape unit given in the MML command is in the OFF LINE state. Press the ON LINE button on the front panel of the unit.

83 PHYSICAL END

The end mark of the tape has been detected. If the tape should not be at the end, check the condition of the tape and, when necessary, clean the read head and change the tape.

84 WRITE SECTION NOT FOUND

No write section is found in the reel-to-reel tape unit specified in the MML command. Open the tape.

85 FILE TRANSFER SYSTEM BUSY (PROGRAM BLOCK MEMDAT)

The program block MEMDAT is not capable of receiving new tasks. Try again.

86 FILE TRANSFER SYSTEM BUSY (PROGRAM BLOCK DUMPER)

The program block DUMPER is not capable of receiving new tasks. Try again.

87 FILE TRANSFER SYSTEM BUSY (PROGRAM BLOCK FULLER)

The program block FULLER is not capable of receiving new tasks. Try again.

88 FILE TRANSFER SYSTEM BUSY (PROGRAM BLOCK LOADER)

The program block LOADER is not capable of receiving new tasks. Try again.

89 FILE TRANSFER SYSTEM BUSY (PROGRAM BLOCK UPDATE)

The program block UPDATE is not capable of receiving new tasks. Try again.

90 LOADING ABORTED

The program block DUMPER has interrupted the loading of the files due to a loading error. Try again.

91 ERROR IN LOADING MESSAGE

There is an error in the loading message. The loading message has been distorted on the message bus. Try again.

92 END OF FILE FOUND

The file is loaded up to the end mark. The file to be loaded is shorter than indicated by the program block which has requested the loading.

Page 13: DX Error Messages

DN987378Issue 24-0

13

General Error Messages of System DX error messages

Id:0900d8058077e097

The situation is normal if the MEMDAT program block has been requested to update the whole file.

93 INCORRECT FILE NUMBER

The file number is incorrect. Check that the file number is correct and that it belongs to the files of the source unit or the target unit.

94 NO RESPONSE

No acknowledgement is received from the LOADER program block to a loading message. Check the operation of the ASS bus and the LOADER program block.

95 LENGTH ERROR IN LOADING

Loading error. Check that the number of bytes to be updated which is given to the MEMDAT program block is no larger than the file length.

96 NO MESSAGE

No message was received by the program block.

97 INCORRECT MESSAGE

The program block does not recognize the task identifier.

98 UNUSABLE STORE

Reading or writing on the disk is not possible. Check that the disk drive is in order and in correct state.

99 DUMPING ABORTED

The sending of files has been interrupted.

100 BEGIN OF TAPE

The tape is at the beginning: A new tape has been inserted into the tape unit or the tape unit has been set in the OFF LINE state with operating switches although the unit should be in the ON LINE state.

101 TIME-OUT ERROR (2)

The TAPEDR program block has been waiting for an interrupt but it has not arrived within the time limit. (The length of timeout supervision is 3-15 seconds, 3 minutes in rewinding.) Cause for the error: 1. The cable of the interrupt line between the TAPI and CPU386 plug-in unit is broken or connected to a wrong pin. 2. The program block has set the address of the interrupt service program incorrectly in the interrupt vector table. 3. The tape unit has moved into the OFF LINE state, possibly because of a disturbance. 4. The tape unit is faulty. 5. The magnetic tape is faulty. Check the items above.

102 WRITE BLOCK TOO LONG

An attempt has been made to write too long a data block on the I/O device. Correct the error in the application process.

103 DUPLICATE PREFORMATTING

An attempt has been made to format a tape already formatted.

104 NOT AT BEGINNING OF TAPE

The tape is not at the beginning as it should be in connection of the for-matting and opening commands. Rewind the tape to the beginning.

Page 14: DX Error Messages

14 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

105 IDENTIFICATION FAILURE

An attempt is made to open a formatted tape with an incorrect identifier (ID). Check the identifier.

106 PREFORMAT MISSING

The opening command has been given for a tape which has not been formatted. Format the tape.

107 MULTIFILE TAPE

An error occurs when a command is given which is allowed only to one-file tapes and there is a multifile tape in the tape unit. Check the tape type and change it when necessary.

108 TAPI UNIT FAILURE

There is a fault in the TAPI plug-in unit. Change the TAPI plug-in unit.

109 DMA UNIT FAILURE

Before a reading or writing task is executed the TAPEDR program block checks in the DMADI plug-in unit the DMA channels which have been reserved for data transfer. If an error is detected, the command will not be executed but a failure status will be returned. Change the DMADI plug-in unit.

110 DATE NOT EXPIRED

An attempt has been made to format a tape with an HDR1 label whose date has not expired. Release the tape or take another tape into use.

111 FORMAT ERROR

The start block is faulty on the track to be closed. The track close task has been directed to a faulty track. Give a new command to the correct track.

112 PRINTER FAILURE

The printer is out of order. Check the printer and the printer cable.

113 SERO BOARD MISSING

The SERO unit of the printer interface is missing or faulty. Check that the SERO unit is in its place and functioning.

114 SERO BOARD FAILURE

The SERO unit of the printer interface is faulty. Check the functioning of the SERO unit and replace it if necessary.

115 I/O DEVICE IN INCORRECT WORKING STATE

Operation has been directed to an I/O device that is not in the WO state. Check the working state of the I/O device and set it into the WO state if necessary.

116 TAPE CHANGE TIME-OUT

A tape change command has been given but the new tape has not been installed quickly enough. Preformat and open the new tape.

117 INCORRECT PARAMETER IN TASK

Page 15: DX Error Messages

DN987378Issue 24-0

15

General Error Messages of System DX error messages

Id:0900d8058077e097

The object data (tape unit number, tape reel, or file name) in the task is incorrect. Correct the object data (application program or logical file incorrect).

118 INCORRECT NUMBER OF DRIVE

The device corresponding to the tape unit index in the task has not been included in the software package in question. Correct the tape unit index or software package so that the required tape unit is included.

119 INCORRECT NAME OF TAPE FILE (ALREADY IN USE)

The file name defined in the MML command is already in use in another tape unit. Open the tape file with a name which is not yet in use.

120 INCORRECT NAME OF REEL (ALREADY IN USE)

The name of the tape reel given in the MML command is already in use in another tape unit. Preformat the tape by using a name which is not yet in use.

121 COMMAND NOT ALLOWED IN THIS TAPE STATE

The MML command is not allowed in the current state of the tape. Correct the working state of the tape. If the tape unit is blocked, it must be set in the ON LINE state again.

122 CHECKSUM ERROR IN SYSTEM MONITORING MESSAGE

The checksum in the message between the OSMONI program block and the application program is incorrect. Repeat the command.

123 WRONG MEMORY OR I/O ADDRESS

The program block OSMONI tries to handle an incorrect memory area. (Write on ROM, no memory area, no input port, etc.) Change the address.

124 MEMORY LACKING IN GIVEN ADDRESS

There is memory space only in part of the area to be filled.

125 PROCESS NOT IN DXPARA

The process identifier is incorrect. Check the process identifier.

126 ASS UNIT BUSY

An attempt is made to write on the memory of the ASS3 (DX 210). An attempt is made to write on the active side of the ASS0-ASS2 memo-ries. It is not possible to write on the memory of the ASS3. Perform swi-tchover.

127 NO RESPONSE FROM PREPROCESSOR

The preprocessor does not respond within time limit. Check that the plug-in unit exists. Try again.

128 TIME LIMIT EXCEEDED IN LOADING

MMIMAN has not received a response to a link or load message from IOMANA within the time limit when loading the MML program, in parts, into the OMU or MSW memory. Try again.

129 UNKNOWN COMMAND

Page 16: DX Error Messages

16 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The requested MML program is not in the MCOMND file or MMIMAN has not accepted MCOMND in its validity checks. Check the MCOMND file. Restart MMIMAN.

130 UNKNOWN COMMAND CLASS

MMIMAN does not recognize the requested command class.

131 MML LOADING ERROR

The dynamic address data in the phased loading of the MML program are not correct. Try again.

132 RESOURCE SHORTAGE

MMIMAN has been unable to reserve all necessary buffers in the loading phase of an MML program. Try again.

133 MML LENGTH ERROR

The MML program on disk is too long for the area reserved for MML pro-grams. Shorten the MML program on disk.

134 CURRENTLY NO SPACE FOR NEW MML

The RAM areas reserved for MML programs are being used by other MML programs and it is not possible to load a new program. Try again.

135 TIME LIMIT EXCEEDED IN INQUIRY

MMIMAN has not received a response within the time limit from IOMANA when inquiring about the MML program length data. Try again.

136 MESSAGE LENGTH ERROR

Message length error noticed by an individual process. NOTICE: THIS IS NOT A DMX ERROR.

143 ALLOCATE ERROR

An allocate error noticed by an individual process. For example, process RAM area overflow: NOTICE: THIS IS NOT A DMX ERROR.

150 INVALID PARAMETER

A parameter noticed invalid by an individual process. NOTICE: THIS IS NOT A DMX ERROR.

154 TIME LIMIT EXCEEDED IN MESSAGE WAITING

The time limit of message receiving has expired. Try again, check the functioning of the partner program block.

159 MODIFICATIONS NOT ALLOWED

File modifications in the CMs are not allowed because either the active or the passive CM is loading its files. Try again.

165 POSITION NUMBER RESERVED

The position number is already in use. Change the position number.

166 FILE ERROR

An error has been found in the CM files while a command is being exe-cuted. See the alarm 2060 CENTRAL MEMORY FILE ERROR, /Failure Print-Outs, Alarm Print-Out Manual, 2.5/.Repeat the command.

Page 17: DX Error Messages

DN987378Issue 24-0

17

General Error Messages of System DX error messages

Id:0900d8058077e097

167 GROUP CALL NUMBER WITH POSITION NUMBER

The given subscriber number is a group call number. Check the sub-scriber number and use hunting group MML commands if necessary.

168 EXTENSION OF HUNTING GROUP

The subscriber belongs to a hunting group. Check the subscriber number and use hunting group MML commands if necessary.

170 DISK NOT UPDATED

No communication with the program block handling disk update, or some other failure in disk update. See the alarm 1065 DISK UPDATE FAILURE, /Disturbance Print-Outs, Alarm Print-Out Manual, 2.5/.

171 SPARE CM UNIT NOT UPDATED

The spare CM is not updated. See the alarm 1064 UNIT UPDATE FAILURE, /Disturbance Print-Outs, Alarm Print-Out Manual, 2.5/.

173 POSITION NUMBER VACANT

Check the position number.

176 INCORRECT FILE NUMBER

There is an incorrect or illegal file number in the counter correction message. Repeat the command, check the parameters.

177 FILE CATALOG ERROR

An error has been detected in file addressing. The file in question is not found in the catalog or the addressing is outside the catalog.

178 NONEXISTENT METER

The STATCO program block has received an incorrect value for one of the following parameters in the meter interrogation MML command: incorrect subscriber number, incorrect circuit group number, incorrect charging zone number, incorrect meter type or class. Repeat the command, check the parameters.

184 FILE MARKED BAD

Operation has been directed to a disk file marked bad.

185 FILE LOCKED BY ANOTHER USER

File is locked. The user has no authority to read the file or write in it.

186 DATA VERIFY ERROR

The data on disk does not correspond to the data in memory. Writing on the disk has failed. The disk formatting has failed.

187 ALTERNATE TRACK ERROR

No alternate track can be found for a track marked bad. Format an alternate track.

188 DISK FULL

The disk is full.

189 NO INDEX PULSES

Page 18: DX Error Messages

18 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The disk controller does not detect disk index pulses. The disk drive is faulty or the disk controller is faulty. Replace the disk drive. Replace the disk controller.

190 NO SEEK COMPLETE

The read/write head of the disk drive does not move correctly. The disk drive or the disk controller is faulty. Replace the disk drive. Replace the disk controller.

191 WRITE FAULT

Writing on the disk fails. The disk drive or the disk controller is faulty. Replace the disk drive. Replace the disk controller.

192 DRIVE NOT SELECTED

The disk drive has not been specified in the command.

193 TRACK 0 NOT FOUND

The disk or the disk controller is faulty. Replace the disk drive. Replace the disk controller.

194 ID FIELD READ ERROR

There is a disk ID field read error. If the error is repeated, the disk drive or the disk controller is faulty. Mark the track bad and format an alter-nate track. Replace the disk drive. Replace the disk controller.

195 UNCORRECTABLE DATA ERROR

An error has been detected in the data to be stored on disk. The error cannot be corrected by the disk controller. Set the read/write head on the track again. If the error does not disappear, mark the track bad and format an alternate track.

196 TARGET SECTOR NOT FOUND

The required block cannot be found on the disk. Mark the track on which the block is located bad and format an alternate track.

197 DATA TRANSFER TIME-OUT

Data transfer between the disk controller and EDISKD has exceeded the time limit. Replace the disk drive. Replace the disk controller. Replace the DMADI plug-in unit.

198 ERROR BURST CORRECTED

The disk controller has detected and corrected incorrect data.

200 INVALID COMMAND

The disk controller does not accept the command it has received from EDISKD. Replace the disk controller.

201 INVALID SECTOR ADDRESS

Wrong block number. The disk controller has been given a block number outside the memory. The disk has not been initialized or the disk drive is faulty. Initialize the disk. Replace the disk drive.

202 VOLUME OVERFLOW

EDISKD has given the disk controller a command, and the value of the parameters is too high.

Page 19: DX Error Messages

DN987378Issue 24-0

19

General Error Messages of System DX error messages

Id:0900d8058077e097

203 RAM FAILURE

The RAM of the disk controller is faulty. Replace the disk controller.

204 ROM FAILURE

The ROM of the disk controller is faulty. Replace the disk controller.

205 ECC HARDWARE FAILURE

There is an error in the correction logic of the disk controller. Replace the disk controller.

207 SCSI BUS IS BUSY

The SCSI bus is busy.

208 NO RESPONSE FROM DMA

Writing on the DMA has failed. Replace the DMADI unit.

209 SENSE DATA TRANSFER FAILED

EDISKD has not received error status from the disk controller. Replace the disk controller.

210 RESET UNSUCCEEDED

The disk controller reset has failed. Replace the disk controller.

211 SCSI BUS ERROR

The cable between the DMADI plug-in unit and the winchester disk con-troller is faulty. Faulty disk controller. Replace cable. Replace disk con-troller.

212 PARITY ERROR

There is a parity error in the data transfer between the disk controller and the DMADI plug-in unit. Try again.

213 ILLEGAL ALTERNATE TRACK ACCESS

The addressing of an alternate track is incorrect or the disk operation has been directed to an alternate track directly (without being first directed to a track marked bad).

214 INVALID ALTERNATE TRACK

The track has already been marked as an alternate track for another track. Choose another alternate track.

215 ALTERNATE TRACK NOT ALTERNATE

An alternate track has been marked for a bad track but no bit of the alter-nate track is found in the ID field of the alternate track. Format the alter-nate track again.

216 BAD TRACK AS ALTERNATE

An attempt is made to mark a bad track as an alternate track. Choose another alternate track.

217 WINCHESTER DISK CHECKSUM ERROR

There is an error in the checksum of the disk directory. Initialize the disk.

218 EDISKD PROGRAM BLOCK BUSY

Page 20: DX Error Messages

20 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

EDISKD is copying the disk; other application processes cannot operate on the disk. Wait till the copying ends.

219 SEGMENT READ ERROR

An error has occurred during an attempt to read a segment.

220 SEGMENT WRITE ERROR

An error has occurred during an attempt to write in a segment.

221 ATTEMPT TO ACCESS ABOVE SEGMENT

An attempt has been made to access above segment.

224 NO SUCH I/O-DEVICE

An application program wants to operate on a device (process) which does not exist on the given MSW level. Give the logical file an I/O device that exists on the MSW level in question.

225 NO SUCH MSW CONNECTION

Application program wants the execution on a higher MSW level, which does not belong to this branch of network (incorrect system identifier). Check the system identifier of the I/O device and try again.

226 MSW TRANSMISSION ERROR

The NETCOM program block has failed to transmit data. Try again if necessary.

227 LOGICAL FILE ALREADY EXISTS

Application program tries to create a logical file with a name which already exists in the tables of IOMANA. Change the name of the logical file to be created if you want to create a new file, or try to delete the old one.

228 I/O-DEVICE CONNECTION FAILURE

Application program has chained too many logical files. Change the I/O device connection of the logical file.

230 NO SUCH LOGICAL FILE

Application program is trying to operate on a logical file that does not exist. Give the right file number in the command.

231 NO FREE BUFFER

The system cannot provide a buffer needed to perform the task. Try again after a while.

232 UNDEFINED COMMAND

Command has not been defined.

233 OVERLOAD IN I/O SYSTEM

There is currently no space available in the tables of IOMANA. Try again after a while.

234 TOO DEEPLY NESTED

There are too many levels in the chain of logical file connections. Change the connections.

235 OBJECT NOT FOUND

Page 21: DX Error Messages

DN987378Issue 24-0

21

General Error Messages of System DX error messages

Id:0900d8058077e097

The object (usually another logical file) connected to the logical file is not found.

236 LOGICAL FILE COUNT EXEEDED

An attempt has been made to create more logical files than the space reserved for them allows. Remove unnecessary logical files.

238 ILLEGAL DEVICE

An attempt has been made to give a task to a device for which it is not allowed.

239 SPARE LOGICAL FILE ALREADY EXISTS

An attempt has been made to create a spare logical file for a logical file which already has a spare logical file.

240 DEVICE NOT IN USE

The I/O device given in the task does not exist in the system or it is not available. Check the working state of the I/O device.

241 PREVIOUS RESERVER INCORRECT

The reserver of the device has been given incorrectly in the command used for releasing an I/O device or for changing the reserver. Check the parameters of the MML command.

242 CHANGE IS NOT ALLOWED

Change is not allowed.

243 ILLEGAL COMMAND

The command cannot be executed because the device is in wrong working state. Check the working state of the device and change it if necessary.

244 DEVICE ALREADY RESERVED

An attempt was made to reserve a device that is already reserved. Try again.

245 ILLEGAL UNIT

An attempt has been made to give the task to a computer unit which is not found in the system.

246 CONTROLLED SWITCHOVER OF TBU NOT ALLOWED BECAUSE TBU IS NOT SYNCHRONIZED TO ANY REFERENCE

CONTROLLED SWITCHOVER OF TBU NOT ALLOWED BECAUSE TBU IS NOT SYNCHRONIZED TO ANY REFERENCE Controlled swi-tchover of TBU is forbidden because TBUs are not synchronized to any synchronization reference. Correct the situation before making switcho-ver. You can do switchover using FCD parameter in switchover command. Using FCD parameter under this circumstance may cause significant disturbance in network element's internal message connec-tions. Worst case scenario is system restart.

247 NOT BIG ENOUGH BUFFER

An attempt to read from a device more data than the biggest possible buffer can hold.

Page 22: DX Error Messages

22 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

248 CONTROLLED TRANSITION TO SP-EX STATE NOT ALLOWED BECAUSE REDUNDANT TBU IS NOT YET INITIALIZED

Controlled transition to SP-EX state is forbidden because redundant TBU is not yet initialized. Typically initialization takes few seconds but under certain circumstances initialization can take up to two minutes. You can execute state transition using FCD parameter in state change command. Using FCD parameter shall cause issue where redundant TBU is not ready for switchover and thus not fulfill definition of 2N redun-dant unit. Under these circumstances switchover of TBU may cause significant disturbance in network element's internal message connec-tions.

249 CONFIGURATION SET NOT ALLOWED

Disk configuration change is not allowed because e.g. both disks are not in the normal working state.

250 NO PERMITTED

An attempt is made to delete a logical file created by another program-block.

251 TIME-OUT ERROR IN I/O SYSTEM

Time limit set by the application program has expired before the I/O program blocks have performed the task. Try again.

252 BUFFER ALLOCATION ERROR

The allocation of the buffer was not successful.

253 NO DATA TO WRITE

There is not data to write.

254 LOGICAL FILE RESERVED

The logical file is reserved. Try again.

255 UNSUCCESSFUL

A general negative response to an interrogation task. This is not an actual error, but a negative answer to an interrogation, the alternative being the status SUCCESS.

257 INVALID SEMAPHORE NAME

The given semaphore name is not smaller than the number of sema-phores defined by parameters.

258 SEMAPHORE PROTECTION VIOLATION

An attempt has been made to use the semaphore in a way that is not allowed to the caller according to the protection parameters.

259 SEMAPHORE INITIALIZATION ERROR

An illegal attempt to initialize the semaphore. Only a non-negative value can be initialized in the counter of the semaphore, and only when the value already is non-negative.

260 ENTER REGION ERROR

The primitive ENTER_REGION is called in a situation in which there already are calls in the critical region. The critical regions can not be chained.

Page 23: DX Error Messages

DN987378Issue 24-0

23

General Error Messages of System DX error messages

Id:0900d8058077e097

261 EXIT REGION ERROR

The primitive EXIT_REGION is called in a situation in which there are no calls in the critical region.

262 BUFFER SIZE ERROR

An attempt has been made to allocate a buffer of the size of zero or a buffer bigger than the maximum theoretical buffer size.

263 BUFFER NOT AVAILABLE

Buffer allocation was not successful within the defined time limit.

264 NO FREE DESCRIPTOR SLOT

No free descriptor slot for the descriptor pointing to the buffer was found in the area of the descriptor table reserved for the dynamic use of the caller or defined process.

265 HANDLE ERROR

The buffer chain of the caller or defined process does not contain a buffer with the defined handle.

266 ERROR IN MESSAGE LENGTH

The length of the message is not within the allowed range.

267 INVALID COMPUTER IDENTIFICATION ERROR

The logical address or preprocessor address in the computer field of the message header is greater than the largest allowed address of this type.

268 COMPUTER DOES NOT EXIST

The combination of the index part in the logical address and the distri-bution extent, in the computer field of the message header, the prepro-cessor address or the physical computer corresponding to the relative address referring to the pair of the own computer has not been defined.

269 NO MBIF

Message transmission requires a message bus, but the logical or physical message bus that should be used in message transmission according to the computer field in the header, has not been defined or it does not exist.

270 HAND NOT REACHABLE

An incorrect message transmission attempt to a hand in a process familyin which no error message transmission to the master is in use. The hand is free or it has not been created (in a lightweight family), or the focus in its message header and in the administration information do not match (when the focus of process identifier is used in the family).

271 MESSAGE QUEUE OVERFLOW

An attempt has been made to send a message to a process the message queue length of which, after the message transmission, would exceed the maximum value defined when creating the process.

272 UNIT SEPARATED

The message transmission requires a message bus, but the message bus interface unit used is not connected to the bus.

Page 24: DX Error Messages

24 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

273 TRANSMIT FIFO NOT EMPTY

A message could not be sent to the message bus since the transmis-sion buffer of the message bus interface unit is not empty. The reason for the failure always is a hardware fault.

274 BUS SENDING FAILED

An attempt to send a message to the message bus has failed, e.g. since the receiving computer does not exist or it is not connected to the message bus. The reason for the failure can also be a hardware fault.

275 LAST BYTE FAIL

Message transmission to the message bus has failed at the point of the last byte. The reason for the failure probably is a hardware fault.

276 TRANSMIT FIFO NOT EMPTIED, NO FAIL DETECTED

An attempt has been made to transmit a message to the message bus. The transmission buffer of the message bus interface unit is not emptied within the time limit, and no transmission fault has been detected.

277 BROADCAST FAILED

An attempt has been made to send a message to the message bus with a general group address. The transmission buffer of the message bus interface unit has not been emptied within the time limit. When a general group address is used, this error code is received instead of error codes received in other transmission methods (BUS SENDING FAILED, LAST BYTE FAIL and TRANSMIT FIFO NOT EMPTIED, NO FAIL DETECTED).

278 NO ACKNOWLEDGEMENT TO REGISTERED MESSAGE RECEIVED

No acknowledgement to a registered message is received from the computer at the point of which this status appears in the acknowledge-ment message.

279 REGISTERED MESSAGE NOT OK

A registered message has not reached the intended receiver in the computer to which the message was addressed.

280 MESSAGE IS TOO LONG

The received message is longer than the defined size of the message receiving area. In this case a part of the message is copied into the receiving area, the rest of the message will be lost.

281 DYNAMIC DESCRIPTOR SLOT RANGE DEFINITION ERROR

The definition of descriptor slots reserved for dynamic use of the pro-cessor is incorrect (CREATE_FIRST, CREATE_PROCESS). The descriptor slots reserved for dynamic use and defined in the loading module of the extension program are not a subset of descriptor slots to be used dynamically by the process (EXECUTE_PROGRAM).

282 PRIORITY ERROR

The priorities defined for the process are not in the right order, or the higher priority exceeds the maximum priority of the family.

283 INVALID PROCESS IDENTIFICATION

Page 25: DX Error Messages

DN987378Issue 24-0

25

General Error Messages of System DX error messages

Id:0900d8058077e097

The defined process identification is not smaller than the number of pro-cesses in the family (lightweight processes in the lightweight family).

284 PROCESS DOES NOT EXIST

The process of the given process identification does not exist. The exis-tence of the master, instead of the lightweight hand, will be checked. The killing or restarting of the process is possible only by using the creation name of the process.

285 PROCESS ALREADY EXISTS

The process of the given process identification does exist. The exis-tence of the master, instead of the lightweight hand, will be checked.

286 INVALID FAMILY IDENTIFICATION

The given family identification is not smaller than the number of process families defined by parameters.

287 FAMILY DOES NOT EXIST ERROR

The process family of the given family identification does not exist.

288 FAMILY ALREADY EXISTS

The process family of the given family identification already exists.

289 MODULE NOT FOUND

The loading module given in the family record is not found in the primary chain. The module is not loaded into the computer, or its name field is incorrect.

290 MODULE TYPE ERROR

The loading module is not of the right type.

291 HAND GROUP COUNT CONFLICT

The family record and the loading module contain contradictory data on the number of hand groups in the family.

292 FAMILY ENVIRONMENT AREA SIZE ERROR

The size of the family environment, calculated according to the data in the family record and loading module, is at least 4 giga bytes.

293 NO ROOM FOR FAMILY ENVIRONMENT AREA

In the computer, there is no big enough, uniform, free memory space for family or extension environment.

294 PROCESS COUNT ERROR

The number of processes in the family (lightweight processes in a light-weight family) counted according to the information in the family record is at least 65535.

295 LDT SIZE ERROR

The number of LDT descriptor slots counted according to the informa-tion in the family record and loading module is smaller than 8192.

296 INVALID SELECTOR

The LDT selector in the family record or the selector of the descriptor, set according to the descriptor parts in the loading module, is illegal.

Page 26: DX Error Messages

26 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

297 DESCRIPTOR SLOT IN USE

An attempt has been made to set a descriptor to a descriptor slot already in use. All the descriptor slots, reserved for dynamic use, must be free, as well.

298 DESCRIPTOR TYPE ERROR

An attempt has been made to set the segment descriptor to IDT, or such a segment descriptor that is not accepted in the DMX environment. The granularity bit may not be set (the maximum size of a segment to be set is 1 megabyte), and the data segment may not be downwards increas-ing.

299 LOCAL AREA ALLOCATION ERROR

There is not enough space in the family or extension environment for a segment, for which a memory space is allocated in connection with the setting of a descriptor. This fault occurs only if an incomplete correction has been made in order to change the size of a segment.

300 FAMILY NOT EMPTY

An attempt has been made to delete the environment of a family that is not empty. The deletion of a family environment is not possible if there are processes in the family, or if a process in another family has changed its name to one belonging to the family that is being deleted.

301 ILLEGAL ATTEMPT TO MODIFY DMXRTE PROCESS FAMILY

An attempt has been made to delete a DMX family or to modify it.

302 PROCESS FROZEN

An attempt has been made to send a message to a process that is frozen due to an exceptional interruption caused by it.

303 FREE EXTENDED MEMORY CHAIN ALREADY INITIALIZED

Free extended memory chain was already initialized when initialization was asked from the operating system.

304 NO FREE TIME LIMIT RECORDS

There are no free time limit records in the computer.

305 TIME LIMIT TO RESET NOT FOUND

The time limit to be reset was not found.

306 TIME LIMIT TO READ NOT FOUND

The time limit to be read was not found.

307 NO ROOM TO WRITE TIME LIMIT WARMING DATA

The defined area is not sufficient for copying the time limits to be warmed up.

308 NO FREE TNSDL TIMER RECORDS

There are no free TNSDL timer records in the computer.

309 TNSDL TIMER TO RESET NOT FOUND

The TNSDL timer to be reset was not found.

310 TNSDL TIMER TO READ NOT FOUND

Page 27: DX Error Messages

DN987378Issue 24-0

27

General Error Messages of System DX error messages

Id:0900d8058077e097

The TNSDL timer to be read was not found.

311 NO ROOM TO WRITE TNSDL TIMER WARMING DATA

The defined space is not sufficient for copying the TNSDL timers to be warmed up.

312 NO FREE WAKE UP RECORDS

There are no free wake-up records in the computer.

313 WAKE UP TO RESET NOT FOUND

The wake-up to be reset was not found.

314 NO FREE TIMER SERVICE RECORDS

There are no free timer service records in the computer.

315 TIMER SERVICE TO RESET NOT FOUND

The timer service to be reset was not found.

316 LOGICAL BUS NOT DEFINED

The logical bus, required for message transfer, has not been defined.

317 SORTER NOT DEFINED

The sorter, required when transferring messages, has not been defined.

318 NO ROOM FOR ACKNOWLEDGEMENTS TO REGISTERED MESSAGE

When sending a registered message, the space reserved for computer unit-specific acknowledgements was insufficient. The message-sending primitive is, therefore, not collecting any acknowledgements.

319 FAMILY SERVICES IN USE

The use of the given primitive is not allowed in the process using the family services of the General On-Line Library (LIBGEN).

320 SETTING OF MESSAGE TRAFFIC MONITORING FAILED

Both monitoring records are reserved.

321 RESETTING OF MESSAGE TRAFFIC MONITORING FAILED

The process attempting to remove message traffic monitoring had not set message traffic monitoring.

322 DEBUGGING SERVICE SET BY OTHER PROCESS

Setting the debugging service failed because some other process already has set the service.

323 NO DEBUGGING SERVICE SET BY PROCESS

The process attempting to remove the debugging service was not the one that had set it.

324 THE COMPUTER IS ALREADY STOPPED

Setting of debugging service failed because the computer has already been stopped.

325 A PROCESS IS ALREADY STOPPED

Setting of debugging service failed because a process has already been stopped.

Page 28: DX Error Messages

28 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

326 INCORRECT FULL PROCESS ID

The primitive is directed to a process which is identified with a concise process id. However, the name which the process is using at the moment differs from the name given, thus the primitive does not recog-nize it.

327 COMPUTER GROUP NOT FOUND

The record representing the computer group, and the data of which the operating system primitive was to read or modify, cannot be found in the group address table.

328 COMPUTER NOT FOUND FROM GROUP

The computer cannot be found in the group the caller of the operating system primitive had given.

329 NO ROOM FOR GROUP RECORD

There is no room for the group record in the memory space it was to be copied.

330 GROUP ADDRESS TABLE FULL

There is no room for a new or a bigger record in the group address table.

331 MESSAGE ROUTING TABLE FULL

There is no room for a new record in the message routing table.

332 NOT LOGICAL ADDRESS

A computer address that was to be logical is not logical.

333 NOT PHYSICAL ADDRESS

A computer address that was to be physical is not physical.

334 WRONG MESSAGE

The operating system primitive received a wrong message.

335 NO ANSWER

The operating system primitive received no answer.

336 NOT DONE

The service that was asked by a call of an operating system primitive was not executed.

339 ADDRESS RANGES OVERLAP

The address range defined by the post office overlaps with an address range defined earlier.

340 INVALID POST DISTRICT INDEX

The district index of the post office is invalid.

341 GENERAL GROUP DEFINITION ERROR

Error in general group definition: both general groups have not been defined or own computer cannot be found in either group.

343

Requested DSP service type is currently disabled in some or all DSP service pools.

417 CALLER OF LIBGEN FUNCTION UNAUTHORIZED

Page 29: DX Error Messages

DN987378Issue 24-0

29

General Error Messages of System DX error messages

Id:0900d8058077e097

The prioritized functions of LIBGEN are called by an unauthorized process.

418 PARAMETERS OF LIBGEN FUNCTION ERRONEOUS

The parameters to be transmitted to the LIBGEN function are incorrect.

419 RESOURCES RESERVED BY LIBGEN FUNCTION INSUFFICIENT

The resources to be reserved in the LIBGEN function are insufficient.

420 USE OF LIBGEN FUNCTION ERRONEOUS

The LIBGEN function is called incorrectly.

421 MESSAGE USED BY LIBGEN FUNCTION INVALID

The message to be transmitted to the LIBGEN function is incorrect.

422 HAND USED BY LIBGEN FUNCTION IS FREE INSTEAD OF BEING RESERVED

The hand to be transmitted as a parameter to the LIBGEN function is no longer reserved although the function is for reserved hands.

423 NO REAL HAND RESERVATION TIME-OUTS

The LIBGEN function HAND_RESERVATION_TIMEOUT returns this error code when the routine is called unnecessarily (=time limit of hand reservation has not expired).

424 TIME-OUT IN ENTERING MESSAGE REMOTE PROCEDURE CALL

An error code returned by the call of the MSG_RPC_THROUGH_WINDOW routine when the service is not received at all within the defined period.

425 TIME-OUT IN RECEIVING ANSWER MESSAGE TO REMOTE PRO-CEDURE CALL

An error code returned by the MSG_RPC_THROUGH_WINDOW routine when in the routine, no answer message is received after the message transmission within the defined time limit.

426 GIVEN WINDOW NOT FOUND IN MSG_RPC_THROUGH_WINDOW-ROUTINE

The flow control window given as a parameter to the MSG_RPC_THROUGH_WINDOW routine is not found.

512 ILLEGAL PASSWORD

The password is given incorrectly from the terminal.

513 ERROR IN READING PASSWORD FILE

Reading of the password file from disk has failed.

514 NO AUTHORITIES FOR SESSION

The process starting the session has no authorities. The authority data has not been found.

515 ILLEGAL TERMINAL STATE

The terminal starting a session is not in a state in which it is allowed to start a session.

516 ILLEGAL DIALOG STATE

Page 30: DX Error Messages

30 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The starting of a session has failed because it is not possible to start several sessions on the terminal, or the terminal is in state BLOCKED.

517 MML CHECKSUM ERROR

The check sum of the MML program has changed. Copy the MML program from back-up copy to disk.

518 NO SUCH LANGUAGE

The change of language has failed. The defined language is not avail-able.

519 MML MACRO NAME MISSING

There is no MML macro name after the @ sign starting the execution of the MML macro.

520 ILLEGAL MARK IN MML MACRO START LINE

There is an illegal mark in the start line of a MML macro.

521 MML MACRO NAME IS TOO LONG

The MML macro name is too long.

522 MISSING END MARK IN MML MACRO START LINE

The end mark is missing at the end of the start line of a MML macro.

523 ILLEGAL MML MACRO NAME

The name of the MML macro in the command line differs from the one defined in the MML macro.

524 TOO MANY SUB-MML-MACRO CALLS

The maximum number of nested sub-MML-macros has been exceeded.

525 ILLEGAL MML MACRO DATA AREA HANDLE

The allocation of the data area of an MML macro has failed.

526 MML MACRO PARAMETER SYNTAX DEFINITION ERROR

A syntax error in the parameter definition of an MML macro.

527 ILLEGAL MML MACRO CALL PARAMETER

The string that has been given as a parameter is illegal. Check the string and the definition of the parameter of the MML macro.

528 MML MACRO LOADING ERROR

The loading of an MML macro from the disk to the data area failed.

529 MML OUTPUT BUFFER HANDLING ERROR

Handling error of the execution output buffer of the MML program.

530 MISSING SEMICOLON IN DEFINITION PART

The semicolon is missing at the definition part of the MML macro.

531 DEFINITION ERROR IN MML MACRO

There is an incorrect definition in the MML macro.

532 TOO MANY VARIABLE DEFINITIONS

The maximum number of variable definitions has been exceeded.

533 COMMAND EXECUTION ABORTED

Page 31: DX Error Messages

DN987378Issue 24-0

31

General Error Messages of System DX error messages

Id:0900d8058077e097

A Non-MML-program announcement of the command execution abor-tion.

534 COMMAND EXECUTION FAILED

A Non-MML-program announcement of the command execution failure.

535 COMMAND IGNORED

A Non-MML-program announcement of the command having been ignored.

536 COMMAND ORDERED

A Non-MML-program announcement of the command having been ordered.

537 COMMAND BLOCKED

A Non-MML-program announcement of the command execution abortion due to blocking.

544 COMMAND NOT AUTHORIZED

Command execution not authorized.

545 TRANSMISSION ERROR

Data transmission to the I/O-device failed.

597 AUTO CLOSE EXECUTED

The tape has filled up. The TAPEDR program block closes the file, rewinds the tape and sets the tape drive into state OFF LINE.

598 LOGICAL END

The logical end of the tape (two successive tape characters) has been found during the command execution.

599 FILE LABEL NOT COMPLETE

An incorrect label structure has been found during the command exe-cution.

600 LAST FILE NOT CLOSED

The last file on the tape has not been closed.

601 TAPE FILE ALREADY EXISTS

An attempt has been made to open a file on tape, with the multifile open command, with a name that is in use already.

602 NAME MISMATCH WITH LAST FILE

A file name has been given in the file reopen command, that does not match with the name in the end label of the last file on tape.

603 REOPEN NOT ALLOWED

The reopen command is directed to a tape drive that does not contain DX tape.

604 ILLEGAL TAPE TYPE

An attempt has been made to set an illegal tape type with the tape type set command.

605 TAPE PREFORMATTED

Page 32: DX Error Messages

32 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An attempt has been made to search for a file on a preformatted tape, or to open the first file on tape with the multifile open command.

606 TAPE WRITE PROTECTED

A writing has been directed to a tape unit with a write protected reel. There is no plastics write protection ring in the reel.

607 NO PID STRING

An attempt has been made to write with the MAS service terminal exten-sion a file from memory to disk the identification character string of which does not match with the file name.

608 NO RESPONSE FROM TAPEDR

The TAPEDR program block does not answer to the sent message.

609 NO RESPONSE FROM EDISKD

The EDISKD program block does not answer to the sent message.

768 GENERAL ERROR OF RECOVERY

The general fault situation indicator of the recovery system.

769 WAIT FOR UNIT RESTART PERMISSION

The unit restart is not possible due to the states of other functional units.

770 NO RESPONSE TO SUPERVISION MESSAGE

The program block has not answered the supervision message.

771 BAD RESPONSE TO SUPERVISION MESSAGE

The program block has detected a fault situation on start-up, or the program block is in an incorrect working state.

772 NO RESPONSE TO LOADING INQUIRY

The USAPRO program block of the source has not acknowledged the loading inquiry.

773 NO LOAD GROUPS FOUND

The load group has not been found in the file loading list file (FLLIST) or in the load group file (LGROUP).

774 ERRORS IN LOADING PARAMETERS

The control parameters of loading are incorrect.

775 NO RESPONSE TO LOAD COMMAND

The program block performing the loading has not acknowledged the loading command. The total time limit of loading has expired.

776 FILES NOT READABLE

The files of the source are not in order. Loading is not allowed.

777 SOURCE NOT READY

The source is still in the starting state. Loading is not allowed.

778 SOURCE NOT USABLE

The source is in a working state in which loading is not allowed.

779 FAMILY UPDATING FAILURE

Page 33: DX Error Messages

DN987378Issue 24-0

33

General Error Messages of System DX error messages

Id:0900d8058077e097

Updating has not started in the active unit. The process family has acknowledged with the NOK status, or the time limit has expired.

780 FAMILY WARM-UP FAILURE

The warm-up of a process family has failed. The process family has acknowledged with the NOK status, or the time limit has expired.

781 FAMILY STATE NOT CHANGED

The process family has not changed its working state, or the time limit of acknowledgement has expired.

782 FAMILY NOT READY FOR SWITCHOVER

The process family is not ready for switchover, or the time limit of acknowledgement has expired.

783 UNIT STATE INCORRECT

The definition of unit working state has failed. The unit is in an incorrect working state.

784 ERRORS IN TASK DRIVER PARAMETERS IN RCPARA

The control parameters of the execution automaton of the USAPRO program block are incorrect.

785 JOB NOT ACCEPTED

A task concerning unit state administration is not possible due to another task in progress or due to the working state of the unit.

786 SIGNALLING TRAFFIC NOT REMOVED

Removal of signalling traffic has failed.

787 SIGNALLING TRAFFIC NOT STARTED

Starting of signalling traffic has failed.

788 WAIT FOR OUTPUT

The RCXPRO program block requests to stop the MML session because of unit restart.

789 RECOVERY FUNCTION BUSY

The RCXPRO program block is reserved for another recovery function.

790 DATA MISMATCH

An error has occurred in the task analysis.

791 NO RESPONSE FROM UNIT

No acknowledgement to the sent message is received from the unit within the time limit.

792 BAD RESPONSE FROM UNIT

A negative acknowledgement is received to the sent message.

793 TIME-OUT TRIGGER FAILURE

The time limit has expired.

794 DUE TO ACTUAL STATES IN UNITS

The units are in such working states that the task is not possible.

795 TRANSITION NOT CONTROLLED

Page 34: DX Error Messages

34 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The task is not possible controlled.

796 DUE TO MINIMUM CONFIGURATION

The task is not possible controlled since the minimum configuration of units would not be reached.

797 OWN UNIT NOT IN NORMAL WORKING STATE

The working state of own unit prevents the task.

798 UNIT IN TEST

The unit is in test.

799 UNIT IN CALIBRATION

The unit is in calibration.

800 SPARE UNIT NOT FOUND

No working spare unit is found for the unit.

801 UNIT HAS NO LINES TO SERVE

The unit has no external speech lines to be served.

802 RECOVERY FUNCTION FAILURE

A recovery function has been interrupted due to an error.

803 SWITCHOVER FAILURE

The switchover has failed in the unit.

804 WARM UP FAILURE

The warm-up of the spare unit has failed.

805 UNIT RESTART FAILURE

The USAPRO program block has detected an error in the unit restart.

806 UNIT LOADING FAILURE

The unit start-up has failed in file loading.

807 UNIT RESTART FAILED

The final start-up of the unit has failed.

808 INITIALIZATION FAILURE IN SYSTEM RESTART

The exchange restart has failed at the initialization stage.

809 SCDFLE ERROR IN UNIT

The SCDFLE file is incorrect in the unit.

810 SCDFLE UPDATING FAILURE

An error has occurred in the SCDFLE file update.

811 PCMCON DIFFERS FROM SCDFLE

The PCMCON and SCDFLE files contain contradictory data.

812 SCDFLE STATE CONFLICT

There is a conflict between unit working states in the SCDFLE file.

813 CONNECTIONS ARE NOT RELEASED

The connections of a timeslot-based unit are not released.

814 PCMCON DIFFERS IN UNITS

Page 35: DX Error Messages

DN987378Issue 24-0

35

General Error Messages of System DX error messages

Id:0900d8058077e097

The contents in the PCMCON file varies in different units.

815 HARDWARE SWITCHOVER CONTROL FAILURE

The control of switchover logic has failed.

816 FAILURE IN CALL CLEARING

The call clearing has failed.

817 FAILURE IN ASS CHANNEL STATE CONTROL

The state transition of an ASS channel has failed. The opening or closing of an ASS channel has failed, or the files of the accused program block (e.g. ASMANA) are incorrect.

818 ASS CHANNEL UNIT STATE CONTROL FAILURE

The state transition of a unit connected to an ASS channel has failed. It is possible that the ASS channel of the unit is closed, or no acknowl-edgement is received to the state transition command from the unit. The error may also be in the ASS channel files.

819 LIBRARY INITIALIZATION FAILURE

When starting up, the library manager has noticed an error in the initial-ization of a library that it is responsible for. The fault may be a missing file, or an error in the files or tables to be initialized.

820 HOT RESET NOT ACCEPTED

The hot reset of the unit is not possible. The unit is still on the starting-up phase.

821 REWARMING IN PROGRESS

The rewarming of a process family or an individual process is in prog-ress.

822 OMU IS NOT ON TRIAL SIDE

The OMU is not on trial side.

823 ILLEGAL TRIAL SIDE

An illegal trial side. An attempt has been made to add the unit into trial from the wrong side of the two OMU units.

824 MAINTENANCE COMPUTER NOT ACTIVATED

The new maintenance computer does not activate.

825 TRIAL_MSG_S MESSAGE FAILURE

No acknowledgement to the TRIAL_MSG_S message has been received from the maintenance computer of the other side of the exchange.

826 SUITABLE TRIAL UNIT NOT FOUND

A suitable trial unit is not found.

827 SUITABLE NOSWITCH UNIT NOT FOUND

A suitable NOSWITCH unit is not found for trial.

828 UNIT IS NOT IN TRIAL

The unit is not in trial.

829 TRIAL UNIT NOT FOUND

Page 36: DX Error Messages

36 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The trial unit is not found.

830 NOSWITCH UNIT NOT FOUND

The NOSWITCH unit is not found.

831 MAINTENANCE COMPUTER NOT FOUND

The maintenance computer of the other side not found.

832 EXCHANGE IS NOT SPLIT

The exchange is not split up.

833 TRAFF_SWITCHOVER_UNIT_S MESSAGE FAIL

No OK acknowledgement is received to the message TRAFF_SWITCHOVER_UNIT_S.

834 RESTART_TO_UNIT_S MESSAGE FAIL

No OK acknowledgement is received to the message RESTART_TO_UNIT_S.

835 OMU IS IN TRIAL

The OMU is in trial.

836 UNITS IN BL-STATE ARE NOT IDLE

The units in BL-state are not ready for traffic switchover.

837 OMU HAS NOT NEW PACK

The new package has not been loaded into the OMU.

838 UNIT IS IN TRIAL

The unit is in trial.

839 CM/CAC NOT IN TRIAL

The central memory unit (CM/CAC) is not in trial.

840 UNITS IN ILLEGAL STATE AND NOT READY FOR TRAFFIC SWI-TCHOVER

Some units are not in the normal working state and, thus, not ready for traffic switchover or for starting the splitting of the exchange.

841 TWO REPLACEABLE N+1 UNITS HAVE IDENTICAL LOGICAL ADDRESS IN SCDFLE

Two replaceable N+1 units have an identical logical address in the SCDFLE file.

842 MODIFICATION OF MB TO LOGICAL ADDRESS FAILED

Modification of a message bus address into a logical address has failed.

843 LOGICAL ADDRESSES OF N+1 REPLACEABLE UNITS ARE DIF-FERENT IN DATA BANK UNIT.

The logical addresses of N+1 replaceable units are different in the data bank unit.

844 FAILURE IN MAINTENANCE OF CALL CONTROL

A failure in the maintenance of the call control. The failure is due tothe change of state in question and can result e.g in a failure to clear the calls in the faulty unit, or in a failure to establish new ones in the unit to be taken into use.

Page 37: DX Error Messages

DN987378Issue 24-0

37

General Error Messages of System DX error messages

Id:0900d8058077e097

845 FAILURE IN D-CHANNEL STATE CONTROL

The state change of a D channel has failed. The opening or closing of a D channel has not succeeded, or the files of the accused program block (e.g. PXNETM) are faulty.

846 D-CHANNEL UNIT STATE CONTROL FAILURE

The state change of a unit connected to the D-channel has failed. It is possible that the D-channel of the unit is closed, or no acknowledge-ment is received to the state change command. The fault may also be in the D-channel files.

847 SCDFLE CORRUPTED IN UNIT

The SCDFLE file is corrupted in the unit.

848 CREATE OR REMOVE FAILED TO SCDFLE IN UNIT

Creating or removing of some unit failed in the SCDFLE file of the unit.

849 UNIT IN EMERGENCY MODE

Unit of RSS is in emergency mode.

850 RECOVERY FUNCTION CANCELLED BY ANOTHER RECOVERY FUNCTION

A recovery function has been cancelled by another recovery function.

851 WARMING PAIR IS BROKEN UP

The warming pair of a unit with N+1 redundancy is broken up by a unit failure.

852 SAVING OF EXCITATION IS NOT SUCCESSFUL

The saving of an excitation was not successful.

924 HOPL cannot be deleted if it is used by ADJL.

HOPL cannot be deleted if it is used by ADJL.

925 AbsPrioCellReselec and AdjLAbsPrioCellReselec always have unique values.

AbsPrioCellReselec and AdjLAbsPrioCellReselec always have unique values.

926 HOPL NOT FOUND

HOPL NOT FOUND

927 HOPL ALREADY CREATED

HOPL ALREADY CREATED

928 HOPL COLLECTION FULL

HOPL COLLECTION FULL

929 ADJL NOT FOUND

ADJL NOT FOUND

930 ADJL COLLECTION FULL

ADJL COLLECTION FULL

931 MAXIMUM OF ADJLs FOR WCEL

MAXIMUM OF ADJLs FOR WCEL

Page 38: DX Error Messages

38 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

932 ADJL ALREADY CREATED UNDER WCEL

ADJL ALREADY CREATED UNDER WCEL

933 WCEL-HSCAPABILITYHOPERIOD MUST BE SET AS 0 IF WCEL-DCELLHSDPACAPAHO IS ENABLED

WCEL-HSCapabilityHOPeriod must be set as 0 if WCEL-DCellHSD-PACapaHO is enabled.

934 WCEL-DCELLHSDPAENABLED CAN BE ENABLED ONLY WHEN RNC-HSDPAMOBILITY IS ENABLED

WCEL-DCellHSDPAEnabled can be enabled only when RNC-HSDPA-Mobility is enabled.

935 IP ADDRESS ATTRIBUTE ALREADY EXISTS

The IP address attribute already exists.

936 PACKET ABIS FEATUTURE IS NOT SUPPORTED FOR THIS BTS SITE TYPE

PACKET ABIS FEATUTURE IS NOT SUPPORTED FOR THIS BTS SITE TYPE.

937 BTS SOFTWARE DOES NOT SUPPORT PACKET ABIS FEATURE

BTS software does not support Packet ABIS feature

938 WRONG D-CHANNEL TYPE

WRONG D-CHANNEL TYPE

939 DURING WCEL MODIFICATION,SECTORID CANNOT BE MODIFIED IF DCELLHSDPAENABLED PARAMETER IS ALREADY ENABLED

During WCEL modification,SectorId cannot be modified if DCellHSD-PAEnabled parameter is already enabled.

940 WBTS MUST NOT BE CONNECTED TO COCO OR IPNB OBJECT WHEN WBTS-NBAPCOMMMODE IS MODIFIED.

WBTS must not be connected to COCO or IPNB object when WBTS-NBAPCommMode is modified.

941 The unit does not support multirate PCM speed

The unit does not support multirate PCM speed. This can happen, for example, when the interface unit HW is upgraded and the existing TDM or Ater resources are to be reused for the new interface unit.

942 CONGESTION CAUSED BY OVERLOAD PROTECTION IN RM2

Resource reservation was not allowed by overload protection.

943 CER/CEA:ORIGIN REALM AND REMOTE REALM CHECK ERROR.

CER/CEA:Origin realm and remote realm check error.

944 CER/CEA: APPLICATION ID CHECK ERROR.

CER/CEA: Application ID check error.

945 CER/CEA: REMOTE HOST CHECK ERROR.

CER/CEA: Remote HOST check error.

946 OPTIONAL AVP NOT FOUND IN DIAMETER MESSAGE.

Optional AVP not found in diameter message.

Page 39: DX Error Messages

DN987378Issue 24-0

39

General Error Messages of System DX error messages

Id:0900d8058077e097

947 Given IP subnet covers or be covered by an existing one

Given IP subnet covers or be covered by an existing one

948 MULTI CELL OPERATION NOT AVAILABLE

Multi Cell Operation not available

949 AOIP TRANSCODER IN BSS FEATURE IS NOT IN USE

AoIP Transcoder in BSS feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

950 AOIP TRANSCODER IN MGW FEATURE IS NOT IN USE

AoIP Transcoder in MGW feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

951 AOIP TRANSCODER IN MGW AND AOIP TRANSCODER IN BSS FEATURE IS NOT IN USE

AoIP Transcoder in MGW and AoIP Transcoder in BSS feature are not enabled in BSC. Either feature licence is not valid or feature status is in disabled status.

952 RNC-NULLNRIFORCSPOOL MUST BE UNIQUE WITHIN RNC-IUOP-ERATOR

RNC-NullNRIForCSPool must be unique within RNC-IuOperator.

953 RNC-NULLNRIFORPSPOOL MUST BE UNIQUE WITHIN RNC-IUOP-ERATOR

RNC-NullNRIForPSPool must be unique within RNC-IuOperator.

954 CSDAP IS ALREADY ATTACHED TO BCF

CSDAP has already been attached to a BCF.

955 UNIDIRECTIONAL MODE OF OPERATION IS NOT SUPPORTED FOR THIS INTERFACE UNIT TYPE

Use of the uni-directional mode of operation is not supported for SET units of this interface unit type.

956 TCSM NUMBER GREATER THAN OR EQUAL TO NUMBER OF QTJFIL FILE RECORDS

The TCSM number is greater than or equal to the number of records in the QTJFIL file. If the program block is able to, it returns the number of the file in question which can be output by the MML program. The output of the file name can be necessary, as well.

957 TCSM INFORMATION EXISTENT

SCFPRO program block generates this error code if the etpc_pcm field of the QTJFIL file record is different from initial value (0xFFFF) when adding TCSM information.

958 TCSM INFORMATION NONEXISTENT

SCFPRO program block generates this error code when the etpc_pcm field of file QTJFIL record is initial value(0xFFFF) when deleting, modi-fying or interrogating TCSM information.

959 EXERCISE COMMAND IS NOT SUPPORTED IN UNI-DIRECTIONAL MODE OF OPERATION

Page 40: DX Error Messages

40 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Exercise command is not supported in uni-directional mode of opera-tion.

960 CSDAP IS NOT FOUND

Circuit Switched Dynamic Abis Pool is not found.

961 CSDAP VALUE IS OUT OF RANGE

The configured Circuit Switched Dynamic Abis Pool value is out of range.

962 CSDAP IS ATTACHED TO BCF AND CANNOT BE DELETED

Circuit Switched Dynamic Abis Pool is attached to the BCF and there-fore CSDAP cannot be deleted.

963 PCU TRACK IS CONFIGURED FOR PACKET ABIS USE

PCU TRACK IS CONFIGURED FOR PACKET ABIS USE

964 PACKET ABIS OVER SATELLITE CAPACITY LICENCE EXCEEDED

PACKET ABIS OVER SATELLITE CAPACITY LICENCE EXCEEDED

965 PACKET ABIS OVER SATELLITE FEATURE IS NOT IN USE IN BSC

Packet Abis over Satellite feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

966 PACKET ABIS SECURITY FOR BTS CAPACITY LICENCE EXCEEDED

PACKET ABIS SECURITY FOR BTS CAPACITY LICENCE EXCEEDED

967 PACKET ABIS SECURITY FOR BTS FEATURE IS NOT IN USE IN BSC

Packet Abis for security BTS feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

968 THERE IS NO OPEN ABIS HDLC LINK CONFIGURED IN BCF

THERE IS NO OPEN ABIS HDLC LINK CONFIGURED IN BCF

969 ETP OBJECT NOT FOUND IN RNW DATABASE

ETP OBJECT NOT FOUND IN RNW DATABASE

970 OPTION PACKET ABIS OVER TDM IS NOT IN USE IN BSC

Packet Abis over TDM feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

971 OPTION PACKET ABIS OVER ETHERNET IS NOT IN USE IN BSC

Packet Abis over Ethernet feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

972 PACKET ABIS OVER ETHERNET CAPACITY LICENCE EXCEEDED

PACKET ABIS OVER ETHERNET CAPACITY LICENCE EXCEEDED

973 PACKET ABIS OVER TDM CAPACITY LICENCE EXCEEDED

PACKET ABIS OVER TDM CAPACITY LICENCE EXCEEDED

974 PACKET ABIS OVER TDM OR PACKET ABIS OVER ETHERNET FEATURE IS NOT IN USE IN BSC

Page 41: DX Error Messages

DN987378Issue 24-0

41

General Error Messages of System DX error messages

Id:0900d8058077e097

PACKET ABIS OVER TDM OR PACKET ABIS OVER ETHERNET FEATURE IS NOT IN USE IN BSC

975 UPLINK COMMITTED BURST SIZE LOWER THAN MAXIMUM TRANSFER UNIT

UPLINK COMMITTED BURST SIZE IS LOWER THAN THE MAXIMUM TRANSFER UNIT

976 BU1 ABIS THROUGHPUT THRESHOLD LOWER THAN BU2 ABIS THROUGHPUT THRESHOLD

BU1 ABIS THROUGHPUT THRESHOLD IS LOWER THAN BU2 ABIS THROUGHPUT THRESHOLD

977 PL2 THRESHOLD LOWER THAN PL1 THRESHOLD

Packet loss in Ethernet Abis PL2 threshold is lower than packet loss in Ethernet Abis PL1 threshold

978 HDLC LINK IS CONNECTED TO BCF

HDLC LINK IS CONNECTED TO BCF

979 GPRS ENABLED FOR BTS/SEG OF THE BCF

GPRS ENABLED FOR BTS/SEG OF THE BCF

980 PACKET ABIS NOT SUPPORT EGPRS DYNAMIC ABIS POOL USE

EGPRS DAP attaching to TRX in the BCF which uses packet Abis con-nection is not supported

981 WCEL-MIMOENABLED CAN BE ENABLED ONLY WHEN WCEL-HSUPA2MSTTIEnabled IS ENABLED

WCEL-MIMOEnabled can be enabled only when WCEL-HSUPA2MSTTIEnabled is enabled.

982 HDLC LINK IS NOT CONNECTED TO THE BCF

HDLC LINK IS NOT CONNECTED TO THE BCF

983 HDLC ID ALREADY EXIST

HDLC ID ALREADY EXIST

984 HDLC NAME ALREADY EXIST

HDLC NAME ALREADY EXIST

985 PCU HAS SEGMENT CONFIGURATION

PCU HAS SEGMENT CONFIGURATION

986 PCU SOFTWARE IN SAME TRACK DOES NOT SUPPORT PACKET ABIS FEATURE

PCU SOFTWARE IN SAME TRACK DOES NOT SUPPORT PACKET ABIS FEATURE

987 WRONG ABIS CONNECTION TYPE

WRONG ABIS CONNECTION TYPE

988 HDLC LINK IS NOT CLOSED

HDLC LINK IS NOT CLOSED

989 MAXIMUM COUNT OF ABIS HDLC LINK TO BCF EXCEEDED

MAXIMUM COUNT OF ABIS HDLC LINK TO BCF EXCEEDED

Page 42: DX Error Messages

42 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

990 PCU NOT CONNECTED TO SAME ETP AS THE ETP OF THE BCF

PCU NOT CONNECTED TO SAME ETP AS THE ETP OF THE BCF

991 ETP-PCU CONNECTION ALREADY EXIST

ETP-PCU CONNECTION ALREADY EXIST

992 ILLEGAL ECCCH CONFIGURATION

ECCCH configuration is illegal. ECCCHs must be configured to TSLs 2, 4 and/or 6 of BCCH TRX (in concecutive order) ECCCH is allowed to be configured only to TRX, which has MBCCH channel. MBCCH has only uncombined CCCH subchannels. Any other combination is not allowed.

993 BTS SW DOES NOT SUPPORT ECCCH FEATURE

BCF SW version does not support Extended CCCH feature

994 ECCCH AND E-TRX OR S-TRX CANNOT BE USED SIMULTANE-OUSLY IN A BTS

ECCCH is not allowed to be configured in cell that has unlocked E-TRX or S-TRX.

995 PACKET ABIS DELAY MEASUREMENT FEATURE IS NOT IN USE IN BSC

Packet Abis Delay Measurement feature is not enabled in BSC. Either feature licence is not valid or feature status is disabled

996 TSLS OF HDLC LINKS ARE OVERLAPPING IN PCM.

TSLS OF HDLC LINKS ARE OVERLAPPING IN PCM.

997 ABIS HDLC LINK STATE IS INCORRECT.

ABIS HDLC LINK STATE IS INCORRECT.

998 PCU NOT CONNECTED TO ETP OF THE BCF.

PCU NOT CONNECTED TO ETP OF THE BCF.

999 MAXIMUM COUNT OF PCU TO ETP EXCEEDED.

MAXIMUM COUNT OF PCU TO ETP EXCEEDED.

1000 ETP-PCU CONNECTION DOES NOT EXIST IN RNW DATABASE.

ETP-PCU CONNECTION DOES NOT EXIST IN RNW DATABASE.

1001 DATABASE ERROR WHEN EXECUTE SQL UPDATE STATEMENT

DATABASE ERROR WHEN EXECUTE SQL UPDATE STATEMENT

1002 APP650 HEARTBEAT SUPERVISION FAILURE

APP650 heartbeat supervision failure.

1003 UNABLE TO DISPLAY MEASUREMENT DATA. MEASUREMENT IS NOT ACTIVE

The measurement has not been activated, i.e. there is no ongoing mea-surement.

1004 UNABLE TO DISPLAY MEASUREMENT DATA. READING MEA-SUREMENT FILE FAILED.

Reading the measurement file failed. The file is missing or the content of the file is not valid.

Page 43: DX Error Messages

DN987378Issue 24-0

43

General Error Messages of System DX error messages

Id:0900d8058077e097

1005 BCF ALREADY HAS ANOTHER ATTACHED CSDAP IN INDEX

BCF CSDAP IS ALREADY USED

1006 CSDAP IS ALREADY DETACHED FROM BCF

CSDAP IS ALREADY DETACHED FROM BCF

1007 OSC RX Quality FEATURE IS NOT IN USE IN BSC

OSC RX Quality measurement (OSC_RXQUAL) feature cannot be used because there is no licence installed in BSC (Base Station Con-troller) or the licence has expired or the licence is in wrong state.

1008 TOO MANY CCCHE CHANNELS UNDER ANTENNA HOPPING ENABLED BTS

ECCCH is allowed to be configured only to TSL 2 if cell has Antenna hopping enabled.

1009 MAC address is illegal in ILLLIB

MAC address is illegal in ILLLIB

1010 IP pool is not valid in ILLLIB

IP pool is not valid in ILLLIB

1011 There are no available IP addresses to assign via DHCP

There are no available IP addresses to assign via DHCP

1012 Device not found during search in ILLLIB

Device not found during search in ILLLIB

1013 Search key is invalid for device search in ILLLIB

Search key is invalid for device search in ILLLIB

1014 IP address is not valid in ILLLIB

IP address is not valid in ILLLIB

1015 Default lease time is not defined for DHCP in ILLLIB

Default lease time is not defined for DHCP in ILLLIB

1016 BTS SW DOES NOT SUPPORT EBCCH FEATURE

BCF SW version does not support Extended BCCH feature.

1017 WCEL-MIMOENABLED CAN BE ENABLED ONLY WHEN WCEL-DCELLHSDPAENABLED IS DISABLED IN ALL CELLS UNDER WBTS

WCEL-MIMOEnabled can be enabled only when WCEL-DCellHSD-PAEnabled is disabled in all cells under WBTS.

1018

DSP resource request that was in RM3 queue was requested to be can-celled.

1019 PACKET ABIS GPRS BCFS IN MULTIBCF CONFIGURATION ARE IN DIFFERENT ETPS

BCFs in MultiBCF configuration sharing a GPRS enabled segment has to be configured to same the ETP.

1020 ALL BCF USING GPRS MUST HAVE THE SAME ABIS CONNECTION TYPE.

Page 44: DX Error Messages

44 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

ALL BCF USING GPRS MUST HAVE THE SAME ABIS CONNECTION TYPE.

1021 PACKET BASED TRANSPORT NOT SUPPORT THIS OPERATION

Intended operation is not supported because of packet-based transport is defined on Abis intreface

1022 PACKET TRS E1/T1 FEATURE IS NOT IN USE

Packet TRS E1/T1 feature is not in use in BSC. Licence is missing or feature state is not ON.

1023 PACKET TRS E1T1 FEATURE CAPACITY IS EXCEEDED

Packet TRS E1/T1 feature capacity is exceeded. Increase licence capacity or change Packet TRS E1/T1 usage parameter to value 0.

1024 HDLC OBJECT NOT FOUND IN RNW DATABASE

HDLC OBJECT NOT FOUND IN RNW DATABASE

1025 ABIS CONNECTION TYPE CONFLICT IN GPRS ENABLED MULTIBCF CONFIGURATION

ABIS CONNECTION TYPE CONFLICT IN GPRS ENABLED MULTIBCF CONFIGURATION

1026 PACKET ABIS SYNCHRONOUS ETHERNET FEATURE IS NOT IN USE IN BSC

PACKET ABIS SYNCHRONOUS ETHERNET FEATURE IS NOT IN USE IN BSC.

1027 ETP ID ALREADY EXIST IN RNW DB

ETP ID ALREADY EXIST IN RNW DB

1028 ETP HAS BCF CONFIGURED

ETP HAS BCF CONFIGURED

1029 ETP HAS PCU CONFIGURED

ETP HAS PCU CONFIGURED

1030 MAXIMUM COUNT OF BCF TO ETP EXCEEDED

MAXIMUM COUNT OF BCF TO ETP EXCEEDED

1031 ABIS HDLC LINK USED IN OTHER BCF

ABIS HDLC LINK USED IN OTHER BCF

1032 ETP NOT UPDATED

ETP NOT UPDATED

1033 BCF HAS CSDAP CONFIGURED

BCF HAS CSDAP CONFIGURED

1034 WRONG ETP TYPE

WRONG ETP TYPE

1035 DETACH OPERATION NOT ALLOWED IN BCF CREATION

CSDAP detach operation is not possible in BCF creation.

1036 DXA HAS NO CONNECTION TO BACKEND DATABASE, TRANSAC-TION FAILED

Page 45: DX Error Messages

DN987378Issue 24-0

45

General Error Messages of System DX error messages

Id:0900d8058077e097

The DXA cannot connect to the ONE-NDS.

1037 SUBSCRIBER DOES NOT BELONG TO DATALESS, TRANSACTION FAILED

Not a Dataless subscriber

1038 WCEL-HSPAQOSENABLED CAN BE SET TO CS_VOICE_C ONLY WHEN RNC-FRLCENABLED IS SET TO ENABLED

WCEL- HSPAQoSEnabled can be set to cs_voice_c only when RNC-FRLCEnabled is set to Enabled

1039 EVC CAN NOT BE DELETED AS IT IS BOUND WITH SUBNET

EVC CAN NOT BE DELETED AS IT IS BOUND WITH SUBNET

1040 BU2 ABIS THROUGHPUT THRESHOLD LOWER THAN BU1 ABIS THROUGHPUT THRESHOLD

BU2 ABIS THROUGHPUT THRESHOLD LOWER THAN BU1 ABIS THROUGHPUT THRESHOLD

1041 HDLC NAME CONTAINS INVALID CHARACTERS

HDLC NAME CONTAINS INVALID CHARACTERS

1053 SDH configuration is not allowed because of the destination SET belongs to the LETGR

The SDH configuration is not allowed because of the destination SET belongs to the LETGR.

1054 RNC-AMRLCRELATTXWINDOWRATE1 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE2.

The RNC-AMRLCRelatTXWindowRate1 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate2.

1055 RNC-AMRLCRELATTXWINDOWRATE2 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE3.

The RNC-AMRLCRelatTXWindowRate2 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate3.

1056 RNC-AMRLCRELATTXWINDOWRATE3 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE4.

The RNC-AMRLCRelatTXWindowRate3 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate4.

1057 RNC-AMRLCRELATTXWINDOWRATE4 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE5.

The RNC-AMRLCRelatTXWindowRate4 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate5.

1058 RNC-AMRLCRELATTXWINDOWRATE5 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE6.

The RNC-AMRLCRelatTXWindowRate5 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate6.

1059 RNC-AMRLCRELATTXWINDOWRATE6 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE7

Page 46: DX Error Messages

46 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The RNC-AMRLCRelatTXWindowRate6 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate7.

1060 RNC-AMRLCRELATTXWINDOWRATE7 SHOULD BE SMALLER THAN OR EQUAL TO RNC-AMRLCRELATTXWINDOWRATE8

The RNC-AMRLCRelatTXWindowRate7 should be smaller than or equal to RNC-AMRLCRelatTXWindowRate8.

1061 WCEL-PTXCELLMAX SHOULD BE SMALLER THAN WCEL-MAXDL-POWERCAPABILITY.

WCEL-PtxCellMax should be smaller than WCEL-MaxDLPowerCapa-bility.

1062

Conflicting external user IDs

1063

Error occurred during transaction in external database

1064 UNAUTHORIZED COMMAND CLASS

Users are not authorized to use the requested command class.

1065 UNAUTHORIZED COMMAND GROUP

Users are not authorized to use the requested command group.

1066 If the intra-frequency neighbor cell is controlled by the local RNC, ADJS-AdjsTxDiv must be set to zero

ADJS-AdjsTxDiv must be set to zero if the intra-frequency neighbor cell is controlled by the local RNC.

1067 IF THE INTER-FREQUENCY NEIGHBOR CELL IS CONTROLLED BY THE LOCAL RNC, ADJI-ADJITXDIV MUST BE SET TO ZERO

ADJI-AdjiTxDiv must be set to zero if the inter-frequency neighbor cell is controlled by the local RNC.

1068 IF THE CELL IS CONTROLLED BY THE LOCAL RNC, ADJD -ADJDTXDIV CAN NOT BE MODIFIED

ADJD -AdjdTxDiv cannot be modified if the cell is controlled by the local RNC.

1069 IF WBTS-NBAPCOMMMODE IS SET TO NB/RSXXX, WCEL-AICH-TRATIME MUST BE SET TO ONE

WCEL-AICHTraTime must be set to one, if WBTS-NBAPCommMode is set to NB/RSxxx.

1070 IF WBTS-NBAPCOMMMODE IS SET TO ULTRASITE BTS / FLEXIBTS / PICOBTS, WCEL-CELLRANGE MUST NOT BE SET TO ZERO

WCEL-CellRange must not be set to zero, if WBTS-NBAPCommMode is set to UltraSite BTS / FlexiBTS / PicoBTS.

1071 ETPSIG-C CONNECTION CAN NOT BE CREATED BEFORE ETPSIG-M

ETPSIG-C connection cannot be created before ETPSIG-M

Page 47: DX Error Messages

DN987378Issue 24-0

47

General Error Messages of System DX error messages

Id:0900d8058077e097

1072 ETPSIG-M CONNECTION CAN NOT BE DELETED BEFORE ETPSIG-C

ETPSIG-M connection cannot be deleted before ETPSIG-C

1073 PENDING ETPSIG CONFIGURATION DELIVERY TO ETP UNIT

Pending ETPSIG configuration delivery to ETP unit

1074 THE NUMBER OF LTECELLRESELECTION ENABLED WCELS EXCEEDS THE LICENSE CELL RESELECTION TO LTE CAPACITY LIMIT

The number of LTECellReselection enabled WCELs exceeds the license Cell Reselection to LTE capacity limit

1075 THE NUMBER OF INCOMINGLTEISHO ENABLED WCELS EXCEEDS THE LICENSE ISHO FROM LTE CAPACITY LIMIT

The number of IncomingLTEISHO enabled WCELs exceeds the license ISHO from LTE capacity limit

1076 WCEL-LTECELLRESELECTION CAN BE ENABLED ONLY WHEN CELL RESELECTION TO LTE LICENSE IS ON

WCEL-LTECellReselection can be enabled only when Cell Reselection to LTE license is ON

1077 WCEL-INCOMINGLTEISHO CAN BE ENABLED ONLY WHEN ISHO FROM LTE LICENSE IS ON

WCEL-IncomingLTEISHO can be enabled only when ISHO from LTE license is ON

1078 IF MOCN/MORAN IS ON THEN UNIQUE PLMN ID MUST BE DEFINED FOR EACH CN.

If MOCN/MORAN is on then unique PLMN id must be defined for each CN.

1079 BCF PARAM AND CSDAP ID CANNOT BE MODIFIED TOGETHER

Bcf parameters cannot be modified together with an attach/detach oper-ation.

1080 ATTACH AND DETACH CANNOT BE DONE TOGETHER

Attach and detach operations are not allowed to be done together.

1081 HSUPA 16QAM NOT AVAILABLE

For RAN 1645, HSUPA 16QAM feature

1082 BYTESYNCHRONOUS MAPPING TO TRIBUTARY UNIT IS NOT SUPPORTED FOR SET UNITS OF THIS INTERFACE UNIT TYPE

Bytesynchronous mapping to tributary unit is not supported for SET units of this interface unit type.

1083 NE is busy. NE reset is not possible.

NE is busy due to which reset is not possible.

1084 NE reset request is not valid.

NE reset request is not valid.

1085 NE is not connected through BTS O&M interface.

Page 48: DX Error Messages

48 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

NE is not connected through BTS O&M interface.

1086 Unit is in SWO.

Unit is in SWO.

1087 ATM connection in operation

JIG is operating the ATM connection.

1088 SP APP MXU is not ready.

SP APP MXU is not ready.

1089 APP MXU is in TE state.

APP MXU is in TE state.

1090 Unit not found in JIG

Unit not found in JIG

1091 ALP unit not found in JIG

ALP unit not found in JIG

1092 JIG's own half cross connection creation task not done yet

JIG's own half cross connection creation task not done yet

1093 JIG's VP reporting task not done yet

JIG's VP reporting task not done yet

1094 Unit is being removed in JIG.

Unit is being removed in JIG.

1095 Unit needs ATM reconfig in JIG.

Unit needs ATM reconfig in JIG.

1096 MXU cluster is restarting.

MXU cluster is restarting.

1097 MXU cluster is in warming

MXU cluster is in warming

1098 1st channel of the unit not created yet

1st channel of the unit not created yet

1099 JIG allocates internal ATM res failed

JIG allocates internal ATM res failed

1100 Conn not found in JIG

Conn not found in JIG

1101 No free hands of JIG

No free hands of JIG

1102 Diameter destination already exists.

Diameter destination already exists.

1103 Diameter destination does not exist.

Diameter destination does not exist.

1104 Diameter transfer path does not exist.

Diameter transfer path does not exist.

Page 49: DX Error Messages

DN987378Issue 24-0

49

General Error Messages of System DX error messages

Id:0900d8058077e097

1105 Diameter transfer path already exists.

Diameter transfer path already exists.

1106 Diameter transfer path IP already exists.

Diameter transfer path IP already exists.

1107 IUIP NOT FOUND

IUIP NOT FOUND

1108 IUO NOT FOUND

IUO NOT FOUND

1109 CBC NOT FOUND

CBC NOT FOUND

1110 IUIP ALREADY CREATED

IUIP ALREADY CREATED

1111 IUIP COLLECTION FULL

IUIP COLLECTION FULL

1112 IUO ALREADY CREATED

IUO ALREADY CREATED

1113 IUO COLLECTION FULL

IUO COLLECTION FULL

1114 CBC ALREADY CREATED

CBC ALREADY CREATED

1115 CBC COLLECTION FULL

CBC COLLECTION FULL

1116 THIS PROTOCOL IS NOT SUPPORTED FOR SET UNITS OF THIS INTERFACE UNIT TYPE.

This protocol is not supported for SET units of this interface unit type.

1117 Initialization of APP3k has failed.

Initialization of APP3k has failed.

1118 cabinet index is invalid

used for Ui5 MGW

1119 shelf index is invalid

used for Ui5 MGW to create SET

1120 slot index is invalid

used for Ui5 MGW to create SET

1121 AMC slot index is invalid

used for Ui5 MGW to create SET

1122 unit address is out of range

Unit address is out of range.

1123

Page 50: DX Error Messages

50 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The maximum amount of AAL2 paths has already been created to system.

1124 EXTENDED BCCH FEATURE IS NOT IN USE IN BSC

Extended BCCH feature is not enabled in BSC. Licence state is not ON.

1125 NO SUITABLE SERVING PCU FROM ETP OF THE BCF

NO SUITABLE SERVING PCU FROM ETP OF THE BCF

1126 UNKNOWN PARAMETER FOR CBCI IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown CBCI object parameter (or incorrecly placed) in the RNW Plan file.

1127 UNKNOWN PARAMETER FOR IUO IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown IUO object parameter (or incorrecly placed) in the RNW Plan file.

1128 ETP variant is not ETPE. SyncE is supported on ETPE only.

ETP VARIANT IS NOT ETPE

1129 SFP is not Optical.

SFP IS NOT OPTICAL IN ETP

1130 MIMO CAN BE SET AS ENABLED WITH DCELLHSDPA IF BOTH HSUPA AND FDPCH ARE SET ENABLED FOR THIS CELL

MIMOEnabled can be set as enabled with DCellHSDPAEnbaled if both HSUPAEnabled and FDPCHEnabled are set as enabled.

1131 WBTS IPBASEDROUTEIDIUB2 MUST BE UNIQUE FOR ALL WBTS

WBTS IPBasedRouteIdIub2 must be unique for all WBTS.

1132 WBTS IPBASEDROUTEIDIUB MUST BE DEFINED WHEN WBTS IPBASEDROUTEIDIUB2 HAS SOME DEFINED VALUE.

WBTS IPBasedRouteIdIub must be defined when WBTS IPBasedRouteIdIub2 has some defined value.

1133 IUR-DELAYTHRESHOLDMAXIUR MUST BE GREATER THAN IUR-DELAYTHRESHOLDMIDIUR

IUR-DelayThresholdMaxIur must be greater than IUR-DelayThreshold-MidIur.

1134 IUR-DELAYTHRESHOLDMIDIUR MUST BE GREATER THAN IUR-DELAYTHRESHOLDMINIUR

IUR-DelayThresholdMaxIur must be greater than IUR-DelayThreshold-MidIur

1135 UNKNOWN PARAMETER FOR IUIP IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown IUIP object parameter (or incorrecly placed) in the RNW Plan file.

1136 OSC CANNOT OPERATE WITHOUT CSDAP OR PACKET ABIS

OSC (Orthogonal Sub Channel) feature cannot operate without Circuit Switched Dynamic Abis Pool or Packet Abis in use.

Page 51: DX Error Messages

DN987378Issue 24-0

51

General Error Messages of System DX error messages

Id:0900d8058077e097

1137 RNW MULTI CELL OPERATION NOT AVAILABLE AT BTS

RNW Multi Cell operation not available at BTS

1138 WCEL-DCELLHSDPAFMCSID CAN NOT HAVE NOT DEFINED VALUE IF WCEL-DCELLHSDPAENABLED IS SET TO ENABLED

WCEL-DCellHSDPAFmcsId cannot have not-defined value if WCEL-DCellHSDPAEnabled is set to enabled.

1139 MIMOENABLED CANNOT BE SET AS ENABLED WITH DCELLHSD-PAENBALED IF HSUPAENABLED SET AS DISABLED

MIMOEnabled cannot be set as enabled with DCellHSDPAEnbaled if HSUPAEnabled set as disabled.

1140 SFTP SERVER IS ACTIVATED

SFTP Server is still activated. Disable SFTP Server before disabling SSH Server.

1141 PARAMETER GPRIO AND WPRIO CANNOT HAVE THE SAME VALUE

GSM priority is defined as same as WCDMA priority for the segment.

1142 TOO MANY PIC ENABLED CELLS IN PIC POOL

PIC-activated cells in PIC Pool exceed maximum limit.

1143 PIC POOL IS NOT PIC-CAPABLE

PIC pool is not PIC-capable.

1144 PACKET ABIS BCF GROUP ID NOT IN USE

PACKET ABIS BCF GROUP ID NOT IN USE

1145 NO HUB BCF FOR PACKET ABIS BCF GROUP ID

HUB BCF NOT DEFINED FOR THE PACKET ABIS BCF GROUP ID

1146 BCF NOT LOCKED TO PROCEED WITH MODIFICATION

BCF NOT LOCKED TO PROCEED WITH MODIFICATION

1147 PACKET ABIS BCF GROUP ID BELONGS TO DIFFERENT CONNEC-TION TYPE

PACKET ABIS BCF GROUP ID BELONGS TO DIFFERENT CONNEC-TION TYPE.

1148 LOCAL SWITCHING FEATURE IS NOT IN USE IN BSC

Local Switching For Packet Abis feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled.

1149 TERMINAL BCF(S) EXISTS UNDER THE HUB BCF

Terminal BCF(s) exists under the HUB BCF.

1150 LOCAL SWITCHING CAPACITY LICENCE EXCEEDED

LOCAL SWITCHING CAPACITY LICENCE EXCEEDED

1151 MAXIMUM AMOUNT OF BCF IN SAME PACKET ABIS BCF GROUP EXCEEDED

MAXIMUM AMOUNT OF BCFS IN SAME PACKET ABIS BCF GROUP EXCEEDED

1152 PACKET ABIS BCF GROUP ID ALREADY IN USE

Page 52: DX Error Messages

52 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

PACKET ABIS BCF GROUP ID ALREADY IN USE

1153 RNC-RABDRAENABLED CAN BE SET ENABLED ONLY WHEN RNC-HSDPADYNAMICRESOURCEALLOCATION IS SET ENABLED

RNC-RABDRAEnabled can be set enabled only when RNC-HSDPADy-namicResourceAllocation is set enabled.

1154 HMS OPERATION FAILED WHEN PIU POWER OFF.

WHEN PIU IS POWER OFF, HMS RELATED HW OPERATION WILL BE FAILED. PIU HW STAY IN UNSTABLE STATE.

1155

CELL BROADCAST SCHEDULE PERIOD CANNOT BE CHANGED

1156 THIS PIU DOES NOT SUPPORT COLD RESET.

THIS PIU DOES NOT SUPPORT COLD RESET. IF COLD RESET TARGET IS THIS PIU, HMS WILL ABORT THIS OPERATION.

1157 CACHE OVERFLOW FULL

Cache overflow full.

1158 SUBSCRIBER NOT FOUND IN HASH TABLE

Subscriber not found in hash table.

1159 DUPLICATE ID FOUND IN HASH TABLE

Duplicate id found in hash table.

1160 INVALID IMSI

Invalid imsi

1161

ET does not exist.

1162

SET does not exist.

1163

LETGR does not exist.

1164

Peer SET does not exist.

1165

SD_THRESHOLD CANNOT BE BIGGER THAN SF_THRESHOLD.

1166

LINE_LOOPBACK AND DIAGN_LOOPBACK CANNOT BE BOTH ON.

1167

PROTOCOL AND MAPPING MODE NOT MATCHED

1168

Administrative state already exists.

1169

1170

Page 53: DX Error Messages

DN987378Issue 24-0

53

General Error Messages of System DX error messages

Id:0900d8058077e097

Self is unlocked, but parent unit is locked.

1171 NPELIB flow table full

NPELIB: flow table full

1172 NPELIB DID table full

NPELIB: DID table full

1173 NPELIB queue table full

NPELIB: queue table full

1174 NPELIB logical port table full

NPELIB: logical port table full

1175 NPELIB port manager table full

NPELIB: port manager table full

1176 NPELIB invalid flow id

NPELIB invalid flow id

1177 NPELIB invalid DID

NPELIB invalid DID

1178 NPELIB invalid queue id

NPELIB invalid queue id

1179 NPELIB invalid logical port id

NPELIB invalid logical port id

1180 NPELIB invalid port manager id

NPELIB invalid port manager id

1181 Creation of port manager to RSP in APP failed

Creation of port manager to RSP in APP failed.

1182 Deleting of logical port from RSP in APP failed

Deleting of logical port from RSP in APP failed.

1183 Creation of logical port to RSP in APP failed

Creation of logical port to RSP in APP failed.

1184 Creation of queue to RSP in APP failed

Creation of a queue to RSP in APP failed.

1185 Creation of a destination id to RSP in APP failed

Creation of a destination id to RSP in APP failed.

1186 Creation of a flow in APP failed

Creation of a flow in APP failed.

1187 Deleting of port manager from RSP in APP failed

Deleting of port manager from RSP in APP failed.

1188 Deleting of a queue from RSP in APP failed

Deleting of a queue from RSP in APP failed.

1189 Deleting of a DID from RSP in APP failed

Deleting of a DID from RSP in APP failed.

Page 54: DX Error Messages

54 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

1190 Deleting a flow from APP failed

Deleting a flow from APP failed.

1191 Attempt was made to create logical port in APP with Id that already exists

Attempt was made to create logical port in APP with Id that already exists.

1192 Attempt was made to create port manager in APP using ID that already exists

Attempt was made to create port manager in APP using ID that already exists.

1193 Attempt was made to create queue in APP using ID that already exists

Attempt was made to create queue in APP using ID that already exists.

1194 Attempt was made to create destination ID in APP using ID that already exists

Attempt was made to create destination ID in APP using ID that already exists.

1195 Invalid starting ET index. Valid starting ET indexes are 1260, 1344, 1428... (with steps of 84)

Invalid starting ET index. Valid starting ET indexes are 1260, 1344, 1428... (with steps of 84).

1196 PRXMAXORIGTARGETBTS VALUE MUST BE GREATER THAN OR EQUAL TO VALUE OF PRXMAXTARGETBTS

PrxMaxOrigTargetBTS value must be greater than or equal to the value of PrxMaxTargetBTS.

1197 BTSPLUS CANNOT BE MASTER IN SYNCH CHAIN

BTSPlus cannot be configured as master clock BCF in synchronization chain.

1198 ONLY FLEXI BTSS ARE ALLOWED IN SYNCH CHAIN WITH BTSPLUS

Only FlexiEDGE and Flexi Multiradio site types are allowed in the same synch chain with BTSplus.

1199 EXTENDED CELL AND DUAL BAND ARE NOT ALLOWED SIMULTA-NEOUSLY IN THE SAME SEGMENT WITH BTSPLUS

Extended cell or super extended cell features cannot be used simulta-neously in the same segment with BTSplus.

1200 SINGLE BAND CONCENTRIC CELL IS NOT ALLOWED IN BTSPLUS IN MULTIBCF

Single band concentric cell is not allowed when BTSplus and Flexi BTS are configured in the same segment. That is, BTSplus cannot have inner TRXs.

1201 BTS SOFTWARE DOES NOT SUPPORT BTSPLUS CO-SITING

BTS software version does not support multi BCF configuration.

Page 55: DX Error Messages

DN987378Issue 24-0

55

General Error Messages of System DX error messages

Id:0900d8058077e097

1202 OSC and EGPRS are NOT Concurrently Supported in Flexi Edge EPSILON TRXs

OSC and EGPRS are NOT concurrently supported in Flexi Edge EPSILON TRXs.

1203 EMICRO IS NOT ALLOWED IN SYNCHRONIZATION CHAIN

BTSplus eMicro does not support synchronization chain.

1204 DPTRX IS NOT ALLOWED IN THE SAME SEGMENT WITH BTSPLUS

DPTRXs cannot be used in the same segment with BTSplus.

1205 ONLY FLEXI BTSS ARE ALLOWED IN SEGMENT WITH BTSPLUS

Only FlexiEDGE and Flexi Multiradio site types are allowed in the same segment with BTSplus.

1206 EMICRO IS NOT ALLOWED IN MULTI BCF CONFIGURATION

BTSplus eMicro does not support Multi BCF configuration.

1207 BTSPLUS CANNOT BE IN SEGMENT WHERE PCU1 IS USED

PCU2 is required if BTSplus is configured to segment.

1208 ALL HOPPING ENABLED BTSPLUS BTS OBJECTS NOT LOCKED

All hopping enabled BTSplus objects in the segment must be locked when BCCH frequency is modified.

1209 EDAP IS CONNECTED TO BCF WHICH IS NOT LOCKED

BCF must be in locked state when PCM-TSL of EDAP is modified.

1210 PMAX1/PMAX2 TOO HIGH IN SEGMENT WITH BTSPLUS AND FLEXI BTS

The maximum value for PMAX1 and PMAX2 is 18dB in multi BCF con-figuration with BTSplus and Flexi BTS.

1211 Port numbers of interfaces are different

Port numbers of interfaces are different.

1212 ETP and PCU from incompatible HW

ETP and PCU from incompatible HW. Connection between McETP and PCU PIU is not allowed.

1213 TRXSIG, OMUSIG and BCF on incompatible HW

This error is raised if OMUSIG and BCF or TRXSIG and BCF are not on the same HW.

1214 MCPCU HAS CONFIGURATION

The mcPCU has RNW/Gb configuration.

1215 PCU SWITCHOVER

PCU switchover happens when PSE reallocation is going on.

1216

1217 PROTOCOL EXISTS TWO TIMES OR PROTOCOL VALUE IS INVALID OR PROTOCOL VALUE DON'T EXIST.

Page 56: DX Error Messages

56 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Protocol exists twice or protocol value is invalid or protocol value does not exist.

1218 HTTPS PROTOCOL DIDN'T ACTIVATE IN FIFILE FILE.

The https protocol did not activate in FIFILE file.

1219 D-CHANNEL NUMBER OF ETPSIG-C FOR ETP PAIR ARE NOT SAME

The D-channel number of ETPSIG-C for ETP pair should be same.

1220

1221 RNC FLEXULRLCENABLED CAN BE ENABLED ONLY WHEN RNC FRLCENABLED IS ENABLED

RNC FlexULRLCEnabled can be enabled only when RNC FRLCEn-abled is enabled.

1222

Maximum count for AAL2 1 CIDs has been reached in the AAL2 switch-ing unit (e.g. it can be A2SP or NPS1(P) unit).

1223 IF DC-HSDPA IS ENB IN ANY CELL OF THE SEC,MIMO MUST NOT BE ENB IN ANY OTHER CELL THAN DC-HSDPA CELL

If DC-HSDPA is enabled in any cell of the sec, MIMO must not be enabled in any other cell than DC-HSDPA cell.

1224 Update the conflict in external database

Update the conflict in external database

1225 IMSI belongs to other subscriber

IMSI belongs to other subscriber

1226 MSISDN belongs to other subscriber

MSISDN belongs to other subscriber

1227 HLR data already exists for IMSI

HLR data already exists for IMSI

1228 HLR data already exists for MSISDN

HLR data already exists for MSISDN

1229 HLR data already exists for UID

HLR data already exists for UID

1230 AuC data already exists for IMSI

AuC data already exists for IMSI

1231 WCEL-PRXTARGETMAXORIG VALUE MUST BE BIGGER THAN OR EQUAL TO WCEL-PRXTARGET

The WCEL-PrxTargetMaxOrig value must be bigger than or equal to WCEL-PrxTarget.

1232 PARAMETER WCEL-HSPA128USERSPERCELL CAN ONLY BE ENABLED IN WCEL IF WCEL-HSPA72USERSPERCELL IS ENABLED

Page 57: DX Error Messages

DN987378Issue 24-0

57

General Error Messages of System DX error messages

Id:0900d8058077e097

Parameter WCEL-HSPA128UsersPerCell can only be enabled in WCEL if WCEL-HSPA72USersPerCell is enabled.

1233 PARAMETER WCEL-HSPA128USERSPERCELL CAN ONLY BE ENABLED IN WCEL IF WCEL-HSUPAENABLED IS ENABLED

Parameter WCEL-HSPA128UsersPerCell can only be enabled in WCEL if WCEL-HSUPAENABLED is enabled.

1234 WCEL- HSPA128USERSPERCELL CAN BE ENABLED ONLY WHEN THE HSPA 128 USERS PER CELL LICENSE IS ON

WCEL- HSPA128USERSPERCELL can be enabled only when the HSPA 128 Users Per Cell license is On.

1235 The HW of both units are active

The HW of both units are active.

1236 Recovery action for hierarchical unit was only partly executed

Recovery action for hierarchical unit was only partly executed. E.g. some of the child units or parent unit was not correctly handled.

1237 WCEL-HSUPA16QAMALLOWED CAN BE SET AS ENABLED ONLY IF WCEL-MAXTOTALUPLINKSYMBOLRATE IS 5760 KBPS

WCEL-HSUPA16QAMAllowed can be set as enabled only if WCEL-MaxTotalUplinkSymbolRate is 5760 kbps.

1238 LICENSE STATE OF HSUPA16QAM MUST BE ON FOR CELL UNLOCKING WHEN WCEL-HSUPA16QAMALLOWED IS ENABLED

The license state of HSUPA16QAM must be on for cell unlocking when WCEL-HSUPA16QAMAllowed is enabled.

1239 CS AND PS UDP MUX PORTS CAN NOT BE SAME

CS and PS UDP MUX ports for U-PLANE can not be the same.

1240 THE NUMBER OF HSUPA 16 QAM USERS PER BTS ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSUPA 16 QAM users per bts enabled bts exceeds the capacity limit.

1241 VCEL-HSUPAENABLED IS ENABLED, THEN VCEL-HSDPAEN-ABLED MUST BE ENABLED.

If VCEL-HSUPAEnabled is enabled, then VCEL-HSDPAEnabled must be enabled.

1242 BCF HAS TO BE LOCKED SINCE BCF C/U PLANE IP ADDRESS HAS BEEN CHANGED.

BCF HAS TO BE LOCKED SINCE BCF C/U PLANE IP ADDRESS HAS BEEN CHANGED.

1243 WCEL-NUMBEREDCHRESERVEDSHOBRANCHADDITIONS MUST BE LOWER THAN VALUE OF PARAMETER WCEL-MAXNUM-BEREDCHCELL

WCEL-NumberEDCHReservedSHOBranchAdditions must be lower than the value of parameter WCEL-MaxNumberEDCHCell.

Page 58: DX Error Messages

58 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

1244 WCEL-NUMBEREDCHRESERVEDSHOBRANCHADDITIONS MUST BE LOWER THAN VALUE OF PARAMETER WBTS-MAXNUM-BEREDCHLCG

WCEL-NumberEDCHReservedSHOBranchAdditions must be lower than the value of parameter WBTS-MaxNumberEDCHLCG.

1245 ETP IS RESTARTING

Operation cannot be completed because ETP is restarting.

1246 PIU DOES NOT CONTAIN ADAPTER

PIU DOES NOT CONTAIN ADAPTER. ALL ADAPTER OPERATIONS ARE ABORTED.

1247 INCORRECT COORDINATE OR CARTRIDGE NOT CREATED

Cannot find cartridge in a specified location from equipment database (EQUIPM).

1248 PTXTARGET CANNOT TAKE VALUES WHICH ARE GREATER THAN THE VALUE OF PTXCELLMAX

PtxTarget cannot take values which are greater than the value of Ptx-CellMax.

1249 IUR-DELAYTHRESHOLDMIDIUR MUST BE GREATER THAN THE IUR-DELAYTHRESHOLDMINIUR

IUR-DelayThresholdMidIur must be greater than the IUR-DelayThresh-oldMinIur.

1250 Requested CERM functionality is not activated and thus request can not be processed.

Controller Entity Resource Management (CERM) main funtionality (or particular sub-feature) is not activated.

1251 IO DEVICE FBAN HAS BEEN SET. DEVICE STATE NOT CHANGE-ABLE.

When IO area FBAN flag is set to device, for example WDU, device state cannot be changed by the system or operator.

1252 LOCAL MULTIPLE AAL2 CHANNELS RESET BY SYSTEM

Local multiple aal2 channels reset by system.

1253 LOCAL SINGLE AAL2 CHANNEL RESET BY SYSTEM

Local single aal2 channel reset by system.

1254 LOCAL AAL2 RESET BY USER

Local aal2 reset by user.

1255 LOCAL AAL2 LINK RESET BY SYSTEM

Local aal2 link reset by system.

1256 REMOTE AAL2 CHANNEL LEVEL RESET IS RECEIVED

Remote aal2 channel level reset is received.

1257 REMOTE AAL2 PATH LEVEL RESET IS RECEIVED

Remote aal2 path level reset is received.

1258 REMOTE AAL2 LINK LEVEL RESET IS RECEIVED

Page 59: DX Error Messages

DN987378Issue 24-0

59

General Error Messages of System DX error messages

Id:0900d8058077e097

Remote aal2 link level reset is received.

1259 LOCAL AAL2 ESTABLISH REQUEST TIME OUT

Local aal2 establish request time out.

1260 LOCAL AAL2 RELEASE REQUEST TIME OUT

Local aal2 release request time out.

1261 LOCAL AAL2 MODIFICATION REQUEST TIME OUT

Local aal2 modification request time out.

1262

Drop statistics status is inactive.

1263

Drop statistics status is active.

1264

The minute is invalid.

1265

The interval is not specified.

1266

Operation failed.

1267 PTXTARGET CANNOT TAKE VALUES WHICH ARE GREATER THAN THE VALUE OF PTXTARGETTOTMAX

PtxTarget cannot take values which are greater than the value of Ptx-TargetTotMax.

1268

Drop statistics measurement id mismatch.

1269 No PFL object corresponding to PFLIdentifier exists in RNW database.

No PFL object corresponding to PFLIdentifier exists in RNW database.

1270 PFL deletion not allowed as it is linked to WCEL object.

Deletion of PFL object with PFL identifier is not allowed as it is linked to a WCEL object.

1271 There are already 50 PFL objects under RNC object.

Maximum number of PFL objects under an RNC can be 50. This error is reported when there are already 50 PFL object under an RNC and user is trying to create more PFLs under that RNC.

1272 PFL COLLECTION FULL

PFL collection is full under an RNC. There are already 50 PFL objects under the RNC object.

1273 PFL NOT FOUND

No PFL object corresponding to PFLIdentifier exists in RNW database.

1274 PFL WITH SAME ID ALREADY CREATED

PFL WITH THE SAME ID ALREADY CREATED.

1275 PFL cannot be deleted if it is used by WCEL object.

Page 60: DX Error Messages

60 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

PFL deletion is not allowed as it is linked to WCEL object.

1276 VLAN ID FOR UNSECURED AND SECURED M-PLANE TRAFFIC IS DIFFERENT IN BTS

VLAN ID FOR UNSECURED AND SECURED M-PLANE TRAFFIC IS DIFFERENT IN BTS.

1277 WSMLC-UEBASEDAGPS CAN BE ENABLED ONLY WHEN RNC-LCSFUNCTIONALITY IS ENABLED

WSMLC-UEBasedAGPS can only be enabled when RNC-LCSfunction-ality is enabled.

1278 RNC-LCSFUNCTIONALITY CANT BE DISABLED WHEN WSMLC-UEBASEDAGPS IS ENABLED

RNC-LCSfunctionality cannot be disabled when WSMLC-UEBased-AGPS is enabled.

1279 MAXIMUM NUMBER OF OSPF STUB NETWORK CAN BE CONFIG-URED TO AN AREA EXCEEDED

MAXIMUM NUMBER OF OSPF STUB NETWORK CAN BE CONFIG-URED TO AN AREA EXCEEDED.

1280

A synchronous library tries to synchronize the request id and a timeout happened while waiting. The SP process is out of sync.

1281 ADJI-BLINDHOTARGETCELL MUST BE ENABLED ONLY WHEN NEIGHBOUR CELL MNC ADJI-MNC IS SAME AS THIS CELL WCELMNC

ADJI-BlindHOTargetCell must be enabled only when neighbour cell MNC ADJI-MNC is same as cell WCELMNC.

1283 ADJI-BLINDHOTARGETCELL MUST BE ENABLED ONLY WHEN NEIGHBOUR CELL RNC ID ADJIRNCID IS SAME AS THIS CELL RNCID

ADJI-BlindHOTargetCell must be enabled only when neighbour cell RNC id AdjiRNCid is same as cell RNCid.

1284 WSMLC-UEBASEDAGPS CAN BE ENABLED ONLY IF WSMLC-LCS-INTERFACEOPTION IS SET TO IUPC

WSMLC-UEBasedAGPS can be enabled only if WSMLC-LCSInterfa-ceOption is set to IUPC.

1285 ADJS-LAC IS NOT MODIFIABLE IF TARGET CELL IS UNDER OWN RNC

ADJS-LAC is not modifiable if target cell is under own RNC.

1286 ADJS-RAC IS NOT MODIFIABLE IF TARGET CELL IS UNDER OWN RNC

ADJS-RAC is not modifiable if target cell is under own RNC.

1287 ADJS-ADJSSCRCODE IS NOT MODIFIABLE IF TARGET CELL IS UNDER OWN RNC

ADJS-AdjsScrCode is not modifiable if target cell is under own RNC.

Page 61: DX Error Messages

DN987378Issue 24-0

61

General Error Messages of System DX error messages

Id:0900d8058077e097

1288 ADJSTXPWRRACH IS NOT MODIFIABLE IF TARGET CELL IS UNDER OWN RNC

AdjsTxPwrRACH is not modifiable if target cell is under own RNC.

1289 ADJS-ADJSCPICHTXPWR IS NOT MODIFIABLE IF TARGET CELL IS UNDER OWN RNC

ADJS-AdjsCPICHTxPwr is not modifiable if target cell is under own RNC.

1290 WCEL- MBLBRABSETUPENABLED CAN BE ENABLED ONLY WHEN MULTI BAND LOAD BALANCING LICENSE IS ON

WCEL- MBLBRABSetupEnabled can only be enabled when Multi Band Load Balancing license is On.

1291 MULTIPLE ADJI UNDER WCEL WITH SAME ADJIUARFCN SHOULD NOT HAVE BLINDHOTARGETCELL IS ENABLED

BlindHOTargetCell can only be enabled when any other ADJI cell for this cell does not have BlindHOTargetCell is enabled and AdjiUARFCN of both adjacent cells are the same.

1292 Error in retrieving common statistics counters

NPZMGR returns this error code in the message sar_counters_ack_s, if it does not get some common statistics counter from APP3k.

1293 EGPRS TRX NOT ALLOWED IF DIVIDED 1. GENERATION FLEXI EDGE DUAL TRX EXISTS AND HOPPING IS USED WITH OSC

EGPRS TRX is not allowed if Divided 1. generation Flexi EDGE Dual TRX exists and co TRX is in OSC mode in BB/Antenna hopping BTS.

1294 HEADER COMPRESSIONS ARE ENABLED FOR THE BCF

Parameters "Header compression for ML-PPP" and "Header Compres-sion For UDP IP" are allowed to be enabled only if BCF is using Packet Abis over TDM.

1295 IPSEC IS ENABLED FOR THE BCF

Parameter "IPSec Enabled" is allowed to be enabled only if BCF is using Packet Abis over Ethernet.

1296 ETPSIG D channel does not exist

INVALID ETPSIG DCHANNEL

1297 Maximum number of TCSUs in BSC exceeded

MAXIMUM NUMBER OF TCSU EXCEEDED

1298 WCEL-PLMNID must be same with IUCS/IUPS-PLMNID

WCEL-PLMNid must be same with IUCS/IUPS-PLMNid.

1299 WCEL-DCELLHSDPAENABLED CAN BE SET AS ENABLED ONLY IF WCEL-HSDPAENABLED IS ENABLED.

WCEL-DCellHSDPAEnabled can be set as enabled only if WCEL-HSD-PAEnabled is enabled.

1300 FILE IS NOT GZIP FORMAT

The file is not in gzip format (rfc1952). For eSW files (AEMxxxxx.IMG), it is usually a gzip file under a DX header (the DX header is added by

Page 62: DX Error Messages

62 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

dxloada). During eSW update, STE will check whether the file is gzip or not.

1301 BIOS VERSION UNKNOWN

The BIOS version cannot be inquired from flash or disk file.

1302 MANUFACTURER UNKNOWN

Cannot find the manufacturer of the board.

1303 CONGESTION CONTROL CANNOT ENABLED FOR BCF UNLESS RELEVANT PARAMETERS ARE DEFINED

Parameters

1304 UPLINK TRAFFIC SHAPING CANNOT ENABLED FOR BCF UNLESS RELEVANT PARAMETER IS DEFINED

Parameter

1305 PARAMETER UPDATING FAILED TO ACTIVE ETP

PARAMETER UPDATING FAILED TO ACTIVE ETP.

1306 PARAMETER UPDATING FAILED TO PROTECTING ETP

PARAMETER UPDATING FAILED TO PROTECTING ETP.

1307 EXTENDED CCCH FEATURE IS NOT IN USE IN BSC

Extended CCCH feature cannot be enabled due to that there is no licence installed in BSC or licence has been expired or licence is in OFF/CONF state.

1308 EXTENDED CCCH CAPACITY LICENCE EXCEEDED

Capacity of the Extended CCCH licence (Extended CCCH) exceeded.

1309 WSMLC-NETWORKBASEDAGPS CAN BE ENABLED ONLY WHEN RNC-LCSFUNCTIONALITY IS ENABLED

WSMLC-NetworkBasedAGPS CAN BE ENABLED ONLY WHEN RNC-LCSFUNCTIONALITY IS ENABLED.

1310 RNC-LCSFUNCTIONALITY CANT BE DISABLED WHEN WSMLC-NWBASEDAGPS IS ENABLED

RNC-LCSfunctionality cannot be disabled when WSMLC-NwBased-AGPS is enabled.

1420 PROGRAM BLOCK STOPPED

The operator has stopped the program block.

1421 UPDATES TO DISKLOG ARE FORBIDDEN

The program block or operator has forbidden updates in the disklog (log in state 02h or 03h). Change the state or wait until it has been changed.

1422 UPDATE SEQUENCE NUMBER DOES NOT MATCH

The update number in the update message does not match with the update number of the last update in the disklog.

1423 1 DISK NOT OK, NO DUMP

One of the disks does not function. Dumping is not carried out since it is not determined, in the message dump_req_s, to be carried out when only one disk is functioning.

Page 63: DX Error Messages

DN987378Issue 24-0

63

General Error Messages of System DX error messages

Id:0900d8058077e097

1424 1 DISK NOT OK, DUMP ON OTHER

One of the disks does not function. Dumping is carried out on the other disk since this is determined in the message dump_req_s.

1425 BOTH DISKS NOT OK, NO DUMP

Both disks are out of order. Dumping can not be carried out.

1426 DUMP IS ALREADY BEING DONE

Dumping is already being done. The next request can be carried out when the previous one is executed.

1427 WRITING IN DATABASE IS FORBIDDEN

Writing in the database is forbidden (either by operator or program block). Release writing, or wait until it has been released.

1428 NO CONSISTENT DATABASE

The database on both disks is not consistent. Loading can not be carried out of inconsistent databases.

1430 INITIALIZATION FAILED

The execution of initialization routine has failed.

1431 TEST SIGNAL OK

The characteristics of the measured test signal were within permitted limits.

1432 NULL SIGNAL DETECTED

The signal to be measured was not received in the test.

1433 UNSYMMETRICAL SIGNAL DETECTED

An unsymmetrical test signal was detected.

1434 TOO LOW SIGNAL

The strength of the measured test signal was too low.

1435 TOO HIGH SIGNAL

The strength of the measured test signal was too high.

1436 SIGNAL ERROR

The measured test signal was incorrect.

2049 SUBSCRIBER IN LINE BLOCKED STATE

The subscriber line measured has been in the line blocked state during measurement. This is not necessarily a fault condition. The line blocked state may occur when the subscriber is in the OFF_HOOK state without dialling for a certain period of time. In this case the line loop resistance is given as the insulation resistance between the a and b conductors.

2050 LTEST UNIT BUSY

The LTEST unit with which the subscriber line should be measured is reserved for another measurement. Try again after a while. If a sub-scriber line is connected via the LTEST unit to an external measuring device, the connection must be released before the LTEST unit can be used for any other measurements.

2051 LTEST UNIT FAULTY

Page 64: DX Error Messages

64 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The LTEST unit with which the subscriber line should be measured is faulty according to the working condition test. Replace the LTEST unit. See alarm listing for the corresponding ** alarm and check its meaning in Disturbance Print-Outs, Alarm Print-Out Manual, 2.5/ the correspond-ing alarm. Repeat the measurement after 10 minutes from the replace-ment of the plug-in unit.

2052 NO LTEST UNIT DEFINED FOR GIVEN SUBSCRIBER

The LTEST unit with which the subscriber line should be measured is not defined. Check from the LTSUBR file of the OMU which LTEST unit is defined for the measurement of the lines of the subscriber module (SUB). If the module is not mentioned in the file, add the corresponding record defining the LTEST unit and the LTEST group. (Use command DFS). If LTSUBR already contains the record, check from the LTCONF file of the OMU whether configuration data have been defined for the LTEST unit. If there are no configuration data, add them by using the DFS command (if the LTEST unit really is included in the system). After the file modifications, repeat the measurement attempt.

2053 SUBSCRIBER IN BUSY STATE

Subscriber line to be measured is in busy state. Try again after a while.

2054 RINGING GROUP IN BUSY STATE

The ringing group that contains the subscriber line to be measured is in busy state. Try again after a while.

2056 TEST LINE OF LTEST IN USE

Test line of the LTEST unit with which the subscriber line should be measured is reserved for another test. Try again after a while.

2057 SSP CONNECTION FAILURE DURING TEST

The connection to the subscriber module to which the subscriber line is connected is not functioning. This is usually a temporary failure. Try again after a while.

2058 LTEST CONNECTION FAILURE DURING TEST

The connection to the LTEST plug-in unit on which the subscriber line should be measured is not functioning. This is usually a temporary failure. Try again after a while.

2061 SUBSCRIBER CALLED DURING TEST

The subscriber line to be measured received a call during test. Try again after a while.

2062 RINGING GROUP CALL INTERRUPTION

The ringing group to which the subcriber line to be measured belongs received a call during test. Try again after a while.

2063 TIME-OUT OF TEST SUPERVISION IN SUBSCRIBER MODULE

In the SUB to which the subscriber line to be measured belongs, the time limit of testing expired. Try again after a while.

2064 TIME-OUT OF LTEST CONNECTION SUPERVISION

Page 65: DX Error Messages

DN987378Issue 24-0

65

General Error Messages of System DX error messages

Id:0900d8058077e097

The testing time limit of the program block controlling the measurement channel forming the LTEST connection expired during test. Try again after a while.

2065 SWITCHOVER IN SUBSCRIBER STAGE DURING TEST

In the subscriber stage to which the subscriber line to be measured belongs, there was a switchover during test. Try again after a while.

2067 INVALID POSITION NUMBER

The position number with which the subscriber line to be measured was identified is incorrect.

2069 FILE ERROR DETECTED BY LITEST PROGRAM BLOCK

There is no room in the working files of the LITEST program block, or the program block has detected another error in the files. Try again after a while. If the result still is the same, restart LITEST.

2070 LINE TEST OVERLOAD

All the ASS channels in the OMU, that are in the use of LITEST, are already in use which means that a new measurement can not be started. Try again after a while.

2071 TEST LINE OF LTEST UNIT BLOCKED FOR TEST PURPOSES

The test line of the LTEST plug-in unit on which the subscriber line should be measured, is temporarily blocked from testing. Try again after a while.

2072 INSUFFICIENT INSULATION ON LINE

An very small insulation resistance has been detected on the subscriber line that has been measured. Repeat the measurement. If the result still is the same, there is an insulation fault on the line in question, and it must be repaired with other methods.

2073 MODULE INQUIRY FAILURE

The inquiry of subscriber module data from the central memory (CM) has failed. This may be caused by an error in the files of the CM or OMU, or by a communication failure between these units. Try again after a while. If the measurement fails again, check the LTCONF file in the OMU. If it is in order, check whether all the subscriber modules determined as locations of the LTEST plug-in unit have been taken into account in the ASCHAN, MODULE and MDROUT files.

2074 LTMANA TEST INTERRUPT

The measurement is interrupted due to time-out in the control of test unit and test line usage. Try again after a while.

2076 TEST LINE BUSY

The test line is busy. Try again after a while.

2077 TEST LINE RESERVATION FAILURE

The reservation of test line for measurement has failed. Try again after a while.

2078 QUEUEING FOR TEST EQUIPMENT

Page 66: DX Error Messages

66 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The measurement is queueing for test equipment. Try again after a while.

2438 MOVING DISK LOG INTO DATABASE PROHIBITED

Some program block has prohibited moving disk log into database files. You can wait until it is allowed to write in database files again, or you can force a change of status on disklog with the message change_log_state_s. If you do not know who prohibited moving and why it is very dangerous to change the state, do not make the state change since the moving can be prohibited because of such an opera-tion during which it is absolutely forbidden to move disklog, e.g. dumping of database.

4001 DISKLOG IS FULL

The disklog is full. Either the saver hand of DBSMAN has not time to empty it, or the saver hand does not function. DBSMAN can not receive updated until there is room in the dislog. The operator can send to DBSMAN an instruction to empty the disklog with the message move_log_on_files_s.

4333 ZERO NOT ALLOWED FILE NUMBER

Zero is not an allowed file number.

8000 ROUTINE MEASUREMENT EVENT IS ALREADY STARTED

MCALEN has requested ROTEST to start a routine measurement, but ROTEST has detected that such a measurement already is in progress.

8001 ROUTINE MEASUREMENT EVENT IS RUNNING

The routine measurement is in progress.

8002 ROUTINE MEASUREMENT EVENT IS NOT RUNNING

The routine measurement is not in progress. This error code can be received when an attempt has been made to stop the routine measure-ment.

8003 ROUTINE MEASUREMENT EVENT EXISTS

The routine measurement event has been defined. MCALEN returns this error code if an attempt has been made to define a routine mea-surement with an identification that is in use.

8004 ROUTINE MEASUREMENT EVENT WAS NOT FOUND

The routine measurement event was not found in the RTSPAR file of MCALEN.

8005 ROUTINE MEASUREMENT EVENT IDENTIFIER IS AMBIGUOUS

The identifier of a routine measurement event does not unambiguosly refer to a measurement event, in other words several identifiers match with the defined identifier.

8006 ROUTINE MEASUREMENT EVENT IS ALREADY ACTIVE

The routine measurement event already is active in the RTSPAR file.

8007 ROUTINE MEASUREMENT EVENT IS ALREADY INACTIVE

The routine measurement event already is marked as inactive.

8008 ROUTINE MEASUREMENT EVENT WAS INTERRUPTED

Page 67: DX Error Messages

DN987378Issue 24-0

67

General Error Messages of System DX error messages

Id:0900d8058077e097

The routine measurement event is interrupted.

9000 RECEIVED MESSAGE IS OF WRONG LENGTH

The received message is of wrong length.

9001 MESSAGE NOT RECEIVED DUE TO TIME-OUT

It has not been possible to receive a message due to time-out.

9002 NO OMU ASS CHANNELS

No ASS-channels found for the OMU.

9003 ILLEGAL CODE FOR OMU ASS CHANNEL

The type of the OMU ASS-channel to be searched for is incorrect, in other words other than EAL, LTEST or reserved (TSL_BASED).

9004 NO OMU EAL ASS CHANNEL

The EAL-ASS-channels of the OMU are not found.

9005 NO OMU LTEST ASS CHANNEL

The LTEST-ASS-channels of the OMU are not found.

9006 NO SIGNALLING FAMILY

No CCS or channel-specific signalling family is connected with the defined computer unit type.

9007 NO SIGNALLING TYPE

No corresponding CCS or channel-specific signalling unit is found for the defined family identifier.

9008 UNIT IN SE-NH SUBSTATE

The computer unit is not equipped.

9009 NO ET PCM FOUND

No external PCM circuit is found.

9010 LOGICAL COMPUTER ADDRESS NOT FOUND

No logical address is found for the defined computer unit which is to serve an external PCM-circuit.

9011 LST CONNECTED PCM CIRCUIT NOT FOUND

An internal PCM-circuit served by the LSU or CAC is not found.

9012 NO LSU COMPUTER UNIT IN THE GIVEN MB ADDRESS

No LSU unit is found in the given physical address.

9013 ACSERV PROGRAM BLOCK NOT FOUND

An internal PCM-circuit served by the ACSERV program block is not found; for this reason no ASS-index can be returned to the user.

9014 PCM WITH COMMON CHANNEL SIGNALLING NOT FOUND

The DX exchange in question is not a CCS exchange.

9015 NO RESERVED ASS CHANNELS

The OMU has no permanent (reserved) ASS-channels.

9016 NO SIGNALLING UNIT IN MB ADDRESS

Page 68: DX Error Messages

68 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

In the defined physical address there is no CCS or channel-specific sig-nalling unit.

9017 NO VALID COMPUTER IN MB ADDRESS

On the basis of the given physical address, it is not possible to identify the corresponding computer unit (type, index).

9018 ACTIVE CM IN RESET

A CM unit in active state is restarted.

9019 LST PCM FOUND, NO LSA CONNECTIONS TO GSW, SWI

An internal (channel-specific) signalling PCM-circuit has been found, but no connections to GSW or SWI.

9020 NO GSW OR SWI HARDWARE INFO FROM SWICOP

This error code is generated when the SWICOP in the marker does not return information on whether the GSW or SWI is old or new hardware.

9021 PCM SERVED BY TIME SLOT BASED UNIT AND ITS TIME SLOTS NOT FOUND

A PCM circuit served by a time-slot based unit and its time-slots are not found: the value parameter is too big or a record is missing.

9022 UNKNOWN UNIT

The search keys connected with the given computer unit are not found in the PCM-TSL search key table of time-slot-based units of FUNLIB.

9023 BAD PCMCON FILE SEGMENT

The PCMCON file can not be read due to e.g. a missing GDT definition.

9024 STAGE TOO LARGE

Tha value of the stage is too large.

9025 RECORD TO BE CREATED ALREADY EXISTS IN FILE

The record to be created already is in the file.

9026 ATTEMPT TO USE TIMESLOT OF SPECIFIC PCM CIRCUIT JOINTLY

An attempt has been made to use a certain timeslot of a certain PCM circuit jointly.

9027 NO FREE RECORDS INITIALIZED WITH FF FOUND FOR CREATING PURPOSES

No free records initialized with FF are found from the file for creating purposes.

9028 FILE NOT ADDED INTO DISK FILE UPDATE TABLE

The file is not added into the disk file update table because it is full.

9029 ILLEGAL PARAMETER FOR DISK FILE UPDATE TABLE

An incorrect parameter when adding file information into the disk file update table: 1. The file number is not found from the file number table of SCFPRO. 2. The number of the first record to be updated is too big. 3. The number of records to be updated is too big.

9030 ILLEGAL SWITCH

Page 69: DX Error Messages

DN987378Issue 24-0

69

General Error Messages of System DX error messages

Id:0900d8058077e097

An attempt has been made to give or search for an undefined switch type or switch (e.g. SSW40).

9031 SWITCH NOT FOUND

An attempt has been made to give or search for a switch type or switch that has been defined but, however, can not be found from the file to be read or updated.

9032 SSU PCM CIRCUIT NOT FOUND

The PCM circuit supervised by the INREGI program block is not found in the subscriber-stage-specific PCMCON file.

9033 ERROR FROM FUNLIB PROGRAM BLOCK

This error message is generated when the error returned by the FUNLIB program block does not have to be examined more closely.

9034 NEW AND OLD CLS VARIANTS IN EXCHANGE

The exchange configuration includes both an old (CLS) and new (CL1TG, CL2TG...) CLS variant.

9035 FUNCTION OF PREPROCESSOR UNIT NOT FOUND

The given preprocessor unit function is not found in the PIPCMI file.

9036 CLS VARIANT NOT FOUND

A CLS unit is included in the exchange configuration but cannot be found in the OASFIL or FUDCHA file.

9037 PIU DATA ARRAY OVERFLOW

The number of plug-in units found in the equipment database is greater than the size of the array reserved by the application for plug-in unit data.

9038 CARTRIDGE NAME UNKNOWN

The type of the cartridge is not found in HWILIB on the basis of the car-tridge name.

9039 CARTRIDGE IDENTIFICATION UNKNOWN

The name of the cartridge is not found in HWILIB on the basis of the car-tridge identifier (type).

9040 SOFTWARE PACKET IDENTIFICATION NOT FOUND

The identifier of the software packet given is nout found in the equip-ment database.

9041 NAME OF A PLUG-IN-UNIT FUNCTION NOT FOUND

The plug-in unit function name in ASCII form cannot be found.

9042 SUBDATABASE REFRESHMENT REQUESTED

A subdatabase refreshment has been requested. This error code is sent by the SSHPRB program block to the process requesting the updating of the subdatabase. SSHPRB has failed twice in its attempts to update the subdatabase, hence the request for its refreshment.

9043 CHECK SUM NOT CHANGED

The check sum has not changed. The SSHPRB program block compares the check sum it receives against the current check sum in

Page 70: DX Error Messages

70 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

the LIETOL file. If the check sum has changed, SSHPRB returns the (changed) circuit classes to the subscriber module. Otherwise this error code is returned.

9044 DUMMY PARAMETER VALUE

This error code is generated when there is an attempt to read from PRFILE a parameter whose value is in excess of the maximum default allowed.

9045 PARAMETER ACCESS TABLE NOT OK

This error code is generated when there is an unsuccessful attempt to read a PRFILE parameter (a subrecord in PRFILE). The probable reason for this is that there has been an error in the initialisation of the PRFILE access table.

9046 PARAMETER NUMBER IS TOO BIG

This error code is generated when there is an attempt to read from PRFILE a parameter that does not belong to the class given.

9047 PARAMETER CLASS NOT USED

This error code is generated when the given parameter class is not in use in PRFILE.

9048 DB OBJECT IS PSAD / PSFP

This error code is generated when hwi_cart_loc_by_alarm_r finds the given CLAC and alarm group in a rack and not in a cartridge.

9049 RACK OR CABINET NAME IS UNKNOWN

This error code is generated when hwi_rack_type_by_name_r receives an unknown ASCII name.

9050 RACK OR CABINET TYPE IS UNKNOWN

The error code is generated when hwi_rack_name_by_type_r receives an unknown rack type.

9051 PLUG-IN UNIT HAS TOO MANY FUNCTIONS

This error code is generated when the plug-in unit being examined has more facilities than can be held by the current data structures.

9052 PLUG-IN UNIT HAS NO FUNCTIONS

This error code is generated either when no facilities at all are found for the plug-in unit(s), or when no new facilities are found.

9053 MASTER UNIT NOT FOUND

This error code is generated when no master unit or master unit type can be found from the Equipment Database.

9054 NO SUBUNITS FOUND

This error code is generated when no subunits are found for the given master unit (which is included in the Equipment Database) or master unit type.

9055 DATA CORRESPONDING TO THE GIVEN PARAMETER(S) NOT FOUND

Page 71: DX Error Messages

DN987378Issue 24-0

71

General Error Messages of System DX error messages

Id:0900d8058077e097

Data corresponding to the parameter(s) given in a library call is not found.

9056 DUAL PORT MEMORY IS TOO SMALL

This error code is generated when the size of the dual port memory is too small.

9057 EQDATA DATABASE SEARCH COMPLETED

This error code will be generated if no more database objects fulfilling the search criteria could be found from the EQDATA database.

9060 CHANGING OF PARAMETER VALUE DENIED

This error code is generated if it is tried to change a parameter value-when changing is not authorized or parameter has interdependencies to (optional) parameters which are not set. The parameter is located in a parameter file (prfile, fifile, for example).

9061 CHANGING OF ACTIVATION STATUS DENIED

This error code is generated if you have tried to change the activation status of an optional parameter in the FIFILE file and the change is not allowed.

9062 SAME ACTIVATION STATUS ALREADY SET

This error code is generated if you have tried to set an activation status which is already set on an optional parameter in the FIFILE file, for example.

9063 INTERDEPENDENCE TO A NOT CHANGEABLE PARAMETER

This error code is generated if you have tried to read or change value of a parameter which has interdependence to another (optional) parame-ter being not set.

9064 OPTIONALITY PARAMETER IS ACTIVE

This error code is generated when a parameter is defined to be option-allocating in the FIFILE file but the corresponding parameter position in the PRFILE does not have the correct value indicating this.

9065 LOCAL UNIT UPDATE FAILURE

This error code is generated if update of the local, active (WO) unit has failed.

9066 PRFILE READ ERROR

This error code is generated if reading of the General Parameter File PRFILE fails.

9067 FIFILE FILE READ ERROR

This error code is generated if reading of the Feature Information Control File FIFILE fails.

9068 FIFILE FILE DOES NOT EXIST

This error code is generated when trying to access nonexistent FIFILE file.

9069 PARAMETER DATA COLLECTION ERROR

Page 72: DX Error Messages

72 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

This error code is generated if data of the parameters cannot be col-lected.

9070 ALL PARAMETERS OF A CLASS ARE SECRET

This error code is generated when trying to read all parameters of a class and they are secret.

9071 NO DATA OF AN OPTIONALITY PARAMETER

This error code is generated when trying to read or change the value of an optional parameter which cannot be found.

9072 ILLEGAL REFERENCE FIELD IN THE MESSAGE

This error code is generated when the reference field of a parameter update message does not contain the sum of the parameter class and the parameter number fields.

9073 PARAMETER CLASS DOES NOT EXIST

This error code is generated when the given parameter class cannot be found from the parameter files (fifile,prfile,prbfil,...).

9074 PARAMETER NUMBER DOES NOT EXIST

This error code is generated when the given parameter number cannot be found from the given parameter class in the parameter file (fifile,prfile,prbfil,...).

9076 INTERDEPENDENCE PARAMETER NOT FOUND

This error code is generated if the interdependence parameter having legal class and number ID cannot be found from the parameter files (PRFILE, FIFILE, PRBFIL).

9077 PARAMETER NOT FOUND FROM PARAMETER FILES

This error code is generated when the given input parameter has not been found from the parameter files (PRFILE, FIFILE, PRBFIL). The parameter does not mean in this context an interdependence parame-ter.

9078 INTERDEPENDENCE TO CHANGEABLE PARAMETER

This error code is generated when PRFILE parameter has interdepen-dence to a changeable parameter whose value is FALSE.

9079 PARAMETER VALUE IS TOO BIG

This error code is generated if such a value is tried to be updated that exceeds the maximum allowed value.

9080 UPDATE PREVENTED BY UNIT STATE ADMINISTRATION

This error code will be generated when unit state administration does not allow memory file nor disk file updatings.

9081 TRIAL CONFIGURATION ALREADY CREATED

This error code will be generated when operator tries to create trial con-figuration but it has already been done.

9082 CUTOVER ALREADY PERFORMED IN TRIAL

Page 73: DX Error Messages

DN987378Issue 24-0

73

General Error Messages of System DX error messages

Id:0900d8058077e097

This error code will be generated when operator tries to perform cutover operation to trial part of the network element but it has already been done.

9083 CUTOVER NOT PERFORMED IN TRIAL

This error code will be generated when operator tries to perform cutover operation to original part of the network element but cutover has not been performed to trial part earlier.

9084 DELETING TRIAL CONFIGURATION NOT POSSIBLE

This error code will be generated when operator tries to delete trial con-figuration but either of the following conditions is fulfilled:

- when canceling trial configuration cutover has been performed to trial part of the network element

- when completing trial configuration cutover has not been performed to trial part of the network element

9085 UPDATING SOMAFI FILE FAILED IN TRIAL

This error code will be generated when updating request or direct update of the SOMAFI file has terminated to an error during a trial operation.

9086 DISCREPANCY BETWEEN TRIAL SYM UNITS

This error code will be generated when active HMS master node has to bechanged to another sym unit but there exists discrepancy of the cor-rectlocation unit of the node between program blocks involved in the changeprocedure.

9087 TERMINATE MML SESSION IN TRIAL

This error code will be generated if recovery announces as a response to a trial operation request that MML session should be terminated. This kind of situation arises, for example, when restart of a SYM unit is activated in that part of a divided network element where sender of the mentioned trial request is located.

9088 HMS ACTIVE MASTER NODE IN FAULTED SYM UNIT

This error code will be generated whenever HMS active master node is located in faulted System Maintenance Unit. It is possible that some attempts have been made to move the node into a non-faulted SYM unit but they have failed. These error situations are associated with TRIAL operations.

9089 PARAMETER IS NOT FOUND IN PRBFIL

This error code is generated if parameter information is requested but there is no information of parameter in PRBFIL files. The requested parameter is located in a parameter file (prfile, fifile, for example).

9090 IP ADDRESS VERSION IS UNDEFINED

This error code is generated when SWUPDA hand process receives interface data with undefined IP address version from JANINA process family after trial cutover operation has been successfully performed.

9091 INCORRECT BIT MASK COMBINATION

Page 74: DX Error Messages

74 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

This error code is invoked whenever a PHFLIB updating service is called with an incorrect bit mask combination parameter. The extent of the update to be performed by the service is unclear.

9092 USE OF TIME SLOT 16 IS DISABLED

This error code will be generated if client wants to set tsl 16 in use but according to file information use of tsl 16 is disabled. In other words, there is a conflict between the client and file information, concerning use of tsl 16.

9093 PARENT UNIT INDEX NOT FOUND

This error code is generated whenever either a specified (user-given) or unspecified (uninitialised) parent unit index is not found in the configu-ration data. The unspecified index in this context is the value of unit_index_t_any_index_c.

9094 IMA GROUP NOT CREATED

This error code will be generated whenever an attempt is made to modify or delete an IMA group which does not exist. This decision is made according to group_created status info in the IMPARA file.

9095 SET UNITS UNSPECIFIED IN PROTECTION GROUP

This error code is set if none of the section SET unit indexes has been defined as the protection group location info. This kind of situation can arise, for example, when updating the state of a phyTTP that is on top of a protection group.

9096 NO ROOM FOR A NEW SET IN THE PROT. GROUP

This error code is generated whenever a new SET network interface unit cannot be added to a protection group because the group already contains both SETs. Indexes of the SETs are different from the new one.

10001 PAYPHONE NOT IN SUPERVISION

The payphone is not included in the supervision.

10002 SPECIAL ROUTE IN OTHER USE

The special route in question is used by another facility than an announcement.

10003 ANNOUNCEMENT EXISTS

The special route in question is already an announcement record.

10004 ANNOUNCEMENT PARAMETERS EXIST

Announcement parameters with the same name already exist.

10005 ANNOUNCEMENT PARAMETERS NONEXISTENT

Announcement parameters with that name do not exist in the ANNPAR file.

10006 INVALID PARAMETER NAME

The parameter with the given name does not exist.

10007 INVALID SIGNALLING

The outgoing register signalling name was incorrect.

Page 75: DX Error Messages

DN987378Issue 24-0

75

General Error Messages of System DX error messages

Id:0900d8058077e097

10008 SPECIAL ROUTE DEFINED IN ROUTE GROUP

The special route in question is used in routing (defined in the CMORGR file).

10009 NO SPACE FOR ANNOUNCEMENT PARAMETERS

The ANNPAR file is full, there is no space to define new announcement parameters.

10010 NO FREE HANDS AVAILABLE

There are no free hands to execute the task.

10011 CRC MEASUREMENT IS NOT POSSIBLE IN THIS ET UNIT

The CRC errors can not be measured in the ET due to its functional mode.

10012 MODULE FILE INCONSISTENCY (MODULE, MDROUT AND SBDIND FILES)

The module files (MODULE, MRDOUT and SBDIND) are inconsistent. The error can appear only in the acknowledgement message module_inq_s. The fault situation arises when one of the files is in dif-ferent state than the others. E.g. one file contains the basic value and the others data. The user must find out which file or files are incorrect.

10013 ET STATE NOT SE-NH

The state of the ET is not SE-NH, which means that it can not be removed.

10014 CIRCUIT NOT FREE

The circuit is already connected through the switch.

10015 DISCONNECTION UNSUCCEEDED

Disconnection failed in the switch.

10016 INCORRECT BANDWIDTH

The bandwidth value in the message sent by the MML program to the CM was incorrect. The bandwidth was 0, or it was bigger than 30 in PCM with signalling or bigger than 31 in PCM without signalling.

10017 INCORRECT DIRECTION

The direction value in the message sent by the MML program to the CM was incorrect.

10018 CANNOT REMOVE LAST OUTGOING CIRCUIT

Only one outgoing branch is left. The user tried to remove it.

10019 LAST MEMBER OF GROUP CALL

The subscriber to be removed from the hunting group is the last member of the group. In this case the removal is not possible.

10020 INCORRECT MEMBER COUNT

An attempt has been made to add too many members into a hunting group.

10021 MEMBER ALREADY IN USE

Page 76: DX Error Messages

76 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An attempt has been made to add into the hunting group a member that already is a member of another group (in connection with analogue groups).

10022 ALREADY EXTENSION

The subscriber to be added into a hunting group already is a member of another group. However, the subscriber can be added into an ISDN group, since in ISDN groups the same subscriber can be a member of several groups.

10023 NO SUCH HUNTING GROUP

The hunting group given in the command does not belong to the group call number in question.

10024 NO SUCH EXTENSION

The extension given in the command does not belong to the hunting group.

10025 NO HUNTING GROUPS

No hunting groups are connected to the subscriber line given in the command, in other words, it is not a group call number.

10026 TOO MANY EXTENSIONS

An attempt has been made to add too many members into the hunting group. The maximum number is 8 per hunting group.

10027 INCORRECT DMA ACCESS

The DMA plug-in unit does not function. The DMA circuit is faulty. Change the plug-in unit.

10028 DISK DIRECTORY NOT EMPTY

An attempt has been made to destroy a disk directory that contains files.

10029 DISK DIRECTORY FULL

The disk directory is full of files, and the creation of new ones does not succeed anymore.

10030 NO SUCH DIRECTORY ON DISK

An attempt has been made to direct a file operation to a non-existent disk directory.

10031 ERROR IN DISK MEDIUM

The surface of the disk is faulty. Change the disk drive.

10032 FAILURE IN DISK HARDWARE

The disk drive is faulty. Change the disk drive.

10033 DISK COMMAND ABORTED

The execution of a disk command is interrupted.

10034 SCSI CONTROLLER BUSY

The SCSI bus controller of the disk is reserved to the use of another computer unit.

10035 DISK RESERVATION CONFLICT

Page 77: DX Error Messages

DN987378Issue 24-0

77

General Error Messages of System DX error messages

Id:0900d8058077e097

An attempt has been made to reserve the disk from several computer units at the same time.

10036 TOO DEEP DIRECTORY PATH

A too long directory path of a disk file has been defined.

10037 ILLEGAL COMMAND TO THIS DISK FORMAT

The given command can not be executed on the disk format on the disk.

10038 ILLEGAL COMMAND TO THIS DEVICE

The hardware does not support the given task.

10039 FAILURE IN SERO LOOP TEST

The loop test of the SERO plug-in unit has failed. Change the SERO plug-in unit.

10040 SERO TRANSMITTER EMPTY

The transmission buffer of the SERO plug-in unit has been emptied, even though the character transmission is not allowed. Change the SERO plug-in unit.

10041 FIFO FAILURE IN SERO BOARD

The FIFO buffer of the SERO plug-in unit is faulty. Change the SERO plug-in unit.

10042 FIFO CANNOT TRANSMIT DATA ON SERO BOARD

The FIFO on the SERO plug-in unit can not transmit data. Change the SERO plug-in unit.

10043 SERO INCOMING DATA INTERRUPT ERROR

The interruption of incoming data of the SERO plug-in unit does not function. Check the interruption wiring. Change the SERO plug-in unit.

10044 CNTRL-B GIVEN FROM VDU

A notice of the VDUDRI program block to the DIALOG program block, of a CNTRL-B character received from a MML terminal.

10045 CHANGE LANGUAGE IN MML TEXT

A notice of the VDURDI program block to the DIALOG program block, of changing the language of MML texts.

10046 BREAK GIVEN

A notice of the VDUDRI program block to the DIALOG program block, of the BREAK character received from the MML terminal.

10047 CNTRL-Y GIVEN FROM VDU

A notice of the VDUDRI program block to the DIALOG program block, of a CNTRL-Y character received from the MML terminal.

10048 CNTRL-X GIVEN FROM VDU

A notice of the VDUDRI program block to the DIALOG program block, of a CNTRL-X character received from the MML terminal.

10049 SET MML PROGRAM IN TEST MODE

A notice of the VDUDRI program block to the DIALOG program block, of starting the test output of an MML program.

Page 78: DX Error Messages

78 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10050 SERO OUTGOING DATA INTERRUPT ERROR

The interrupt of outgoing data of the SERO plug-in unit does not func-tion. Check the interrupt wiring of the SERO plug-in unit. Change the SERO plug-in unit.

10051 SERO TERMINAL NOT READY

The transmission and receiving circuits of the SERO plug-in unit are not functioning. Change the SERO plug-in unit.

10052 SERO BOARD CHARACTER INPUT ERROR

The character receiving logic of the SERP plug-in unit does not function. Change the SERO plug-in unit.

10053 SERO BOARD CHARACTER INPUT TIME-OUT

The character reading of the SERO plug-in unit has ended due to time-out. Change the SERO plug-in unit.

10054 TIME OUT IN PRINTING MML COMMANDS

The output of MML commands on the printer has failed due to time-out.

10055 ILLEGAL SEGMENT

An attempt has been made to refer to a non-existent segment.

10056 NO SUCH TAPE FILE

The file is not found on the tape.

10057 I/O TASK COMPLETED PARTLY OK

The IOMANA program block has directed a task to several I/O devices at the same time, and all the I/O devices have not succeeded in per-forming the task.

10058 ANNOUNCEMENT PARAMETERS DEFINED IN SPECIAL ROUTE

The announcement parameters are used in announcement(s) (defined in the SPCROU file).

10059 CENTREX CALL NUMBER

The subscriber number is a call number of a CENTREX group.

10060 OUTPUT ERROR TEXT

A notice of the VDUDRI program block to the DIALOG program block, of the user having pressed the CNTRL-7 character. This causes that DIALOG outputs the broader explanation of the MML program error code last displayed on the MML terminal.

10061 RESERVED CENTREX EXTENSION NUMBER

The subscriber number is reserved as an extension number of a CENTREX group.

10062 USART ERROR ON SERO BOARD

The USART circuit of the SERO plug-in unit has detected a failure in the terminal or printer interface. Check that the terminal or printer is con-nected and that the power is on. Change the terminal or printer. Change the SERO plug-in unit.

10063 INCORRECT FILE LIST STRUCTURE - FILE LOADING NOT POSSIBLE

Page 79: DX Error Messages

DN987378Issue 24-0

79

General Error Messages of System DX error messages

Id:0900d8058077e097

The structure of the file list (FLLIST) is incorrect.

10064 MEMBER OF CENTREX GROUP

The subscriber is a member of a CENTREX group.

10065 UNKNOWN SUBSCRIBER

The given subscriber does not exist in database.

10066 UNKNOWN BASIC SERVICE

The given basic service does not exist in database.

10067 SUBSCRIBER ALREADY EXISTS

The operator wants to create a subscriber, that already is created in database.

10068 BUFFERED REPORT NOT FOUND

The required report is not found in the ring buffer.

10069 INTERNAL PRINTING QUEUE OF REBMAN IS FULL

The table into which REBMAN stores the reports to be printed out is full.

10070 BUFFERED REPORT IS QUEUING IN INTERNAL PRINTING QUEUE OF REBMAN

The report output does not start immediately, instead is was placed in the internal printing queue of REBMAN.

10071 SYSTEM DOES NOT CONTAIN SUCH DATABASE

With the commands of the DBHAND MML program, the user has given such a database name that does not exist in the system.

10072 DATABASE DOES NOT CONTAIN SUCH FILE

The database under examination does not contain a database file with the file number in question.

10073 DATABASE DOES NOT CONTAIN SUCH TRANSACTION

The given data base does not contain a transaction or fastread with the given number.

10074 DATABASE LOG BUFFER DOES NOT CONTAIN MORE UPDATES

From the log buffer of a database, the special hand scatterer has already found all updates.

10075 TRANSACTION HAND OF DATABASE HAS NOT COMMITTED TO TRANSACTION

In the database system, the transaction hand which has been chosen to execute a given transaction has not yet committed to the transaction.

10076 TRANSACTION HAS BEEN ABORTED

In the database system, the transaction execution has failed and the transaction has been aborted.

10077 TRANSACTION OR FASTREAD EXECUTION HAS LASTED TOO LONG

Time-out has occurred in the transaction or fastread execution; transac-tion has been aborted.

10078 IN DATABASE SYSTEM RESOURCES HAVE BEEN EXHAUSTED

Page 80: DX Error Messages

80 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

In the database system, too many buffers or hands etc. have been needed. The transaction has been aborted.

10079 FATAL ERROR HAS OCCURRED IN DATABASE SYSTEM

A fatal error has occurred to the database managers or database hands. The execution will be stopped.

10080 TRANSACTION OR FASTREAD ERROR HAS OCCURRED

An error has occurred to the fastread or transaction hand of a database system. The transaction has been aborted.

10081 TRANSACTION HAND HAS ASKED LOG BUFFER AREA IN WRONG TRANSACTION PHASE

The log buffer area is asked for by a transaction hand in the active unit, the corresponding hand of which is not in the same transaction phase in the spare unit.

10082 DATABASE LOG BUFFER ERROR

In the database system, an error has occurred when handling log buffer.

10083 ERRONEOUS TRANSACTION OR FASTREAD PARAMETERS

In a transaction or fastread message, the parameters are not correct.

10084 DATABASE FILE CLASS IS NOT CORRECT

With the commands of the DBHAND MML program, the user has given an incorrect file class.

10085 DATABASE SYSTEM HAS NOT ANSWERED TO TRANSACTION OR FASTREAD REQUEST

The transaction or fastread execution has been requested from a database system but no response has come in time.

10086 BUFFERED REPORT IDENTIFIER IS AMBIGUOUS

Several reports are found with the given identifier, in other words, it is impossible to pick only one report.

10087 DATABASE SYSTEM IS NOT IN NORMAL STATE

The database system is loading, dumping etc. so that it cannot execute the required task.

10088 DUMP FAILED ON ONE DISK, BUT WAS SUCCESSFUL ON ANOTHER

The dumping has failed on one disk. The database is consistent.

10089 DATABASE DUMP FAILED. OLD VERSION OF DATABASE ON DISK WILL BE USED

The dumping has failed on both disks. The database on disks is incon-sistent. Dump again immediately.

10090 WO AND SP UNITS NOT SYNCHRONIZED IN DATABASE SYSTEM

The SP master of the database system has failed to synchronize itself with the WO master. This leads to a fatal error in the spare unit.

10091 DATABASE REQUEST SENT TO WRONG RECEIVER

In the database system, an administrative message has erroneously been sent to the spare unit.

Page 81: DX Error Messages

DN987378Issue 24-0

81

General Error Messages of System DX error messages

Id:0900d8058077e097

10092 DATABASE HAS NO DISK COPY

The database in question is only a RAM database. Disks copies do not exist.

10093 DATABASE SYSTEM TIME-OUT ERROR

A time-out has occurred in the database system.

10094 DATABASE LOADING IN PROGRESS

The database manager is loading database files. Transactions cannot be executed.

10095 SPARE UNIT UPDATE FAILURE

The file update in the spare unit has failed.

10096 DISK READ ERROR

Reading from the disk has failed.

10097 COMMUNICATION FAILURE DURING DATA TRANSFER

An error during the MOVIES data transfer service.

10098 DMA ERROR

Reading from the disk has failed because of a DMA error.

10099 DISK ERROR

Disk drive initialization has failed.

10100 LOAD MODULE IS TOO BIG

The load module is too big, there is no room in the memory.

10101 INCORRECT LOAD MODULE LENGTH

The length data in the load module is bigger than in the disk directory.

10102 NO DISK DATA

The disk data file is not found from the disk.

10103 DIRECTORY NOT FOUND

The directory is not found from the disk.

10104 PACKET DIRECTORY NOT FOUND

The correct packet directory is not found from the disk.

10105 SUBDIRECTORY NOT FOUND

The BLCODE or LFILES subdirectory is not found from the packet directory.

10106 PACKET IDENTIFIER INVALID

The packet identifier in the RAM is invalid.

10107 CHAIN ERROR

The load module chain in the RAM is invalid.

10108 WRONG MODULE

The load module in the RAM and the load list contain different load module names.

10109 MODULE CHECKSUM ERROR

The check sum of the load module is incorrect.

Page 82: DX Error Messages

82 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10110 ILLEGAL MESSAGE

An incorrect message has been received from the BOMBER program block.

10111 BREAK STATE

The normal message exchange has been interrupted e.g. because the BOMBER program block has not found the required load module.

10112 MESSAGE TIME-OUT

The time limit of message exchange has expired.

10113 NO START BIT

In the MB message to be received, the bit indicating its start is not correct.

10114 MESSAGE LENGTH ERROR (2)

The length of the MB message to be received is incorrect.

10115 TARGET AREA TOO SMALL FOR AIMED DATA

The size of the target area is too small for the aimed data to be written into it.

10116 NO SUCH FILE ON DISK

The required file is not found from the disk.

10117 ERRONEOUS PARAMETER IN MOVIES FUNCTION CALL

There is something wrong in the parameters of MOVIES function call.

10118 NOT READY

BOTTOM is asked for in a unit other than the OMU, but BOMBER has not yet received a start message from USAPRO.

10119 NO PERMISSION

The unit asking for load module has no load permission.

10120 LOAD MODULE NOT FOUND

The required module is not found from the chain.

10121 NO MODULE

The unit asking for more data has no module to be loaded.

10122 NO USABLE DISK

Neither of the winchester disks is in state WO-BU.

10123 SWTEST STATUS NOT AVAILABLE

The test status can not be read.

10124 DIFFERENT SWTEST STATUS

The units have a different test status.

10125 DIFFERENT PACKAGE

The units have a different package identifier.

10126 SOWADM BREAK

An error status is received from SOWADM when inquiring the package identifier and/or directory of the package.

Page 83: DX Error Messages

DN987378Issue 24-0

83

General Error Messages of System DX error messages

Id:0900d8058077e097

10127 EDISKD TIME-OUT

No reply received from the EDISKD program block.

10128 PCM HAS SIGNALLING, T16 IS ILLEGAL

TSL 16 is in signalling use. It may not be given as the first TSL.

10129 USER ALREADY EXISTS

The user identification already exists.

10130 USER DOES NOT EXIST

The user identifier does not exist.

10131 APPLICATION FIELD DOES NOT EXIST

The application field does not exists.

10132 NETWORK ELEMENT DOES NOT EXIST

The network element does not exist.

10133 NO PRIVILEGE FOR NETWORK ELEMENT

The user has no authorities to the target network element.

10134 NO PRIVILEGE FOR APPLICATION FIELD

The user has no authorities to the target application field.

10135 NOT LOCAL PAYPHONE LINE TYPE

The line is not a local payphone line according to the central memory (CM). The operation failed.

10136 FIRST HUNTING GROUP OF GROUPCALL NUMBER WITH POSITION NUMBER

The first hunting group of a group call number with a position number can not be removed if there are other hunting groups in the group call number.

10137 HUNTING GROUP ALREADY CREATED

When creating a group call number, the first hunting group is created at the same time (HGR=0) after which only new members can be added into this hunting group.

10138 SUBSCRIBER IS NOT MEMBER OF CENTREX

Only such centrex subscribers that are members of the same centrex hunting group as well can belong to a centrex group call number.

10139 SHORT CIRCUIT TEST IS NOT NEEDED

The short circuit test is not needed. The operation succeeded.

10140 ACTIVE UNIT STATE INCORRECT

The active unit is in some other state than WO-EX.

10141 PASSIVE UNIT STATE INCORRECT

The passive unit is in some other state than SP-EX or SP-UP.

10142 APPLICATION ALREADY EXISTS

The application already exists.

10143 SEMIPERMANENT FILE UPDATING BUSY

The semipermanent file is being updated.

Page 84: DX Error Messages

84 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10144 SWITCHOVER PREPARING

The switchover is being prepared.

10145 DESTINATION BELONGS TO TIME CONTROLLED ROUTING

The destination belongs to time controlled routing and cannot be removed.

10146 APPLICATION DOES NOT EXIST

The application does not exist.

10147 INCORRECT MESSAGE RECEIVED FROM MML PROGRAM

The message sent by an MML program is incorrect.

10148 NONEXISTENT TIME CONTROL

The given time control does not exist in time-controlled routing.

10149 SWITCHOVER

The switchover is in progress.

10150 CONFLICT BETWEEN ACTIVE AND PASSIVE UNIT OAPFIL FILE

The OAPFIL files of the active and passive units contain contradictory information.

10151 COMMUNICATION ERROR BETWEEN PASSIVE UNIT O7MANA AND ODBUPD

Communication between the passive unit O7MANA and ODBUPD program blocks has failed.

10152 COMMUNICATION ERROR BETWEEN ACTIVE UNIT O7MANA AND ODBUPD

Exchange of messages between program blocks O7MANA and ODBUPD in the active unit failed.

10153 COMMUNICATION ERROR AND ONLY PASSIVE UNIT FILES UPDATED

Communication between active unit O7MANA and ODBUPD program blocks has failed. Only passive unit files are updated.

10154 COMMUNICATION ERROR BETWEEN ACTIVE AND PASSIVE UNIT O7MANA

The operation succeeded completely.

10155 FILE UPDATED ONLY IN PASSIVE UNIT

The files are updated only in the passive unit.

10156 FILE UPDATED ONLY IN ACTIVE UNIT

The files are updated only in the active unit.

10157 PACKAGE NOT FOUND

The package is not found in the SOMAFI file.

10158 PACKAGE NOT ACTIVE

All the items listed in the MAFILE file, belonging to the package, are not default versions on the disk.

10159 NO FREE PACKAGE RECORDS IN SOMAFI

Page 85: DX Error Messages

DN987378Issue 24-0

85

General Error Messages of System DX error messages

Id:0900d8058077e097

There are no free records in the SOMAFI file.

10160 PACKAGE IS RUNNING

The package is running in some unit.

10161 DISK READ FAILURE

The disk file can not be read.

10162 FILE ERROR IN SOMAFI

There is a file error in the SOMAFI file.

10163 FILE ERROR IN UNPACK

There is a file error in the UNPACK file.

10164 SOMAFI NOT USABLE

The SOMAFI file can not be read from the disk, or it can not be created as a file.

10165 UNPACK NOT USABLE

The UNPACK file can not be read from the disk, or it can not be created as a file.

10166 SOMAFI UPDATE ON DISK FAILED

The update of SOMAFI does not succeed on either disk.

10167 SOMAFI UPDATE NOT SUCCEEDED ON BOTH DISKS

The update of SOMAFI file succeeded only on the other disk.

10168 SUBSCRIBER IS NOT ANALOG GROUP CALL NUMBER

The subscriber number is not an analog group call number.

10169 SUBSCRIBER IS NOT ISDN GROUP CALL NUMBER

The subscriber number is not an ISDN group call number.

10170 SUBSCRIBER NOT CALL NUMBER OF CENTREX GROUP

The subscriber number is not a CENTREX group call number.

10171 FILE SYSTEM RECOVERY ERROR

The recovery of the file system has failed.

10172 OAPFIL FILE READING FAILED

The reading of a record in the OAPFIL file has failed.

10173 PLUG-IN UNIT CODE RAM WRITE ERROR

Writing in the program memory (RAM memory) of the plug-in unit does not succeed when loading program package into the plug-in unit. The reason for the failure may a faulty plug-in unit, an incorrect bridge con-nection on the plug-in unit, a failure on the DMC bus, incorrect informa-tion on the plug-in unit in the MUFILE file or an incorrect program package (an error in the PISOFT file).

10174 LOADED PLUG-IN UNIT SOFTWARE PACKET CHECK ERROR

When checking the success of program package loading, it has been detected that the check sums counted from the plug-in unit and from the code file are different. The reason for the error may a fault in the memory of the 80386 processor, a faulty plug-in unit, an incorrect bridge connnection on the plug-in unit, incorrect information on the plug-in unit

Page 86: DX Error Messages

86 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

in the MUFILE file or an incorrect program package (an error in the PISOFT file).

10175 OSI ADDRESS CONNECTED TO APPLICATION TO BE DELETED

One or more OSI addresses have been connected to the application to be deleted.

10176 SIZE OF PLUG-IN UNIT SOFTWARE PACKET IS TOO BIG

When loading the program package of the plug-in unit, it has been detected that the size of the dual port memory is smaller than the size of the program package to be loaded. The reason for the error may be an incorrect program package of the plug-in unit, an error in the PISOFT file or incorrect information on the plug-in unit in the MUFILE file.

10177 COMMAND GROUP NOT FOUND

The command group is not found in the MCOMND file.

10178 TAUTHO FILE EMPTY

The TAUTHO file is empty.

10179 AUTHORITIES NOT CHANGED

It has not been possible to change the authorities.

10180 OLD PASSWORD VERIFICATION ERROR

An error has occurred in the verification of an old password.

10181 NEW PASSWORD VERIFICATION ERROR

An error has occurred in the verification of a new password.

10182 MINIMUM PASSWORD LENGTH IS 6

The defined password is too short. The length of a password is at least six characters.

10183 MAXIMUM PASSWORD LENGTH EXCEEDED

The defined password is too long.

10184 USER ID NOT CREATED

It has not been possible to create the user identification.

10185 USER ID NOT DELETED

It has not been possible to delete the user identification.

10186 OWN USER ID

The user has given his own user identification.

10187 PLUG-IN UNIT DESCRIPTOR BUILD ERROR

The creation of a descriptor pointing to the dual port memory of a plug-in unit has failed. The reason for the failure may be incorrect information on the plug-in unit in the MUFILE file, packaging error of the program block creating the descriptor, or an error in the operating system.

10188 TIME LIMIT EXPIRED WHEN LOADING SOFTWARE OF PLUG-IN UNITS

The total time limit of loading plug-in unit software package has expired.

10189 AET ALREADY RESERVED

The AET is already used by an application.

Page 87: DX Error Messages

DN987378Issue 24-0

87

General Error Messages of System DX error messages

Id:0900d8058077e097

10190 ADDRESS INFO OF PLUG-IN UNIT ILLEGAL IN MUFILE

The address information on the plug-in unit in the MUFILE file are incor-rect or incompatible with the plug-in unit type.

10191 MML PROGRAM INITIALIZATION FAILED

The initialization of a MML program has failed. The reason for the error may be e.g. the failure of message exchange with the partner program block.

10192 OFFSET OUT OF SUBRECORD

The offset is greater than or of the same size as the size of a subrecord in the file.

10193 OADFIL FILE READING FAILED

The reading of a record in the OADFIL file has failed.

10194 CONFLICT BETWEEN OAPFIL AND OADFIL FILES

The OAPFIL and OADFIL files contain contradictory information.

10195 GIVEN AET IDENTIFIES REMOTE APPLICATION

The AET given in the command identifies a remote application. Only the AET has been defined for the remote application.

10196 OSI ADDRESS DOES NOT EXIST

The OSI address does not exist.

10197 OSI ADDRESS IS NOT CONNECTED TO APPLICATION

The OSI address has not been connected to a application.

10198 SEMANTIC CHECK FAILED

The message exchange connected to the semantics check has failed with the partner program block.

10200 REMOVAL OF ONLY ACTIVE VERSION NOT ALLOWED

The command to remove a disk file or to change its name has been directed only to the default version of the file, even though other versions of the file exist. This is forbidden since one of the file versions must be a default version.

10201 OBJECT ALREADY EXISTS IN DATABASE

The key value or object number value already has an object in the data-base. This value identifies the object, and it is not possible to create another object with the same value.

10203 OBJECT DOES NOT EXIST

The object does not exist.

10205 OCGFIL FILE READING FAILED

The reading of a record in the OCGFIL file has failed.

10206 CONFLICT BETWEEN OCGFIL AND OADFIL FILES

The OCGFIL and OADFIL files contain contradictory information.

10207 FILE DISTRIBUTION AND DISK UPDATE FAILURE

An error has occurred both in file distribution and in disk update.

10208 WORKFILE UPDATING ON

Page 88: DX Error Messages

88 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The updating of a work file is in progress.

10210 FILE ACCESS ERROR

The file operation has failed (e.g. opening, reading or writing of the file).

10211 INCORRECT NSAP

The combined length of IDI and DSP fields is too great.

10212 PHYSICAL CHANNEL GROUP DOES NOT EXIST

The physical channel group does not exist.

10213 OSI ADDRESS NOT IN LOCKED STATE

The OSI address is not in the LOCKED state.

10214 SEMIPERMANENT FILE UPDATING FAILED

The updating of information in a semipermanent file has failed.

10215 COMMUNICATION ERROR BETWEEN ACTIVE MARKER AND ACTIVE CM

The central memory has sent an update request to the marker, but the marker has not answered within the time limit (12 s). The update of the marker has failed.

10216 COMMUNICATION ERROR BETWEEN ACTIVE SSU AND ACTIVE CM

The central memory has sent an update request to the SSU, but the SSU has not answered within the time limit (12 s). The update of the SSU has failed.

10217 COMMUNICATION ERROR BETWEEN SPARE CM AND ACTIVE CM

The active central memory has sent an update request to the spare central memory, but the spare central memory has not answered within the time limit (12 s). The update of the spare central memory has failed.

10218 NO PERMANENT MEASUREMENT REPORT AVAILABLE TO ET UNIT

The measurement results of the ET unit in question have not been received from the AFS-S plug-in unit.

10219 TEXTPR IN ABNORMAL STATE

TEXTPR is not in a normal operating state and can not perform text for-matting tasks. TEXTPR is in an abnormal operating state when it can not open TEFORM and/or TEOUTP files.

10220 DUPLICATE TEXT FORMING JOB

The same program block has sent a new formatting task while the previous one is still uncompleted.

10221 UNKNOWN TEXT FORMING JOB

The text forming job is unknown to TEXTPR.

10222 NO PHYSICAL CHANNEL GROUPS EXIST

The physical channel groups do not exist.

10223 SERVICE EXISTS

Supplementary service already exists.

Page 89: DX Error Messages

DN987378Issue 24-0

89

General Error Messages of System DX error messages

Id:0900d8058077e097

10224 PRIMARY RATE ACCESS NAME EXISTENT

Primary rate access name already exists.

10225 PRIMARY RATE ACCESS NAME NONEXISTENT

Primary rate access name does not exist.

10226 TIME SUPERVISION GROUP NONEXISTENT

The time supervision group does not exist.

10227 MEASUREMENT REPORT OF ET UNIT NOT PRINTED

The TEXTPR program block has answered with a negative status to the printing request of the ET unit measurement report.

10228 GIVEN OSI ADDRESS NUMBER IDENTIFIES LOCAL OSI ADDRESS

The OSI address number given in the command identifies a local OSI address.

10229 GIVEN OSI ADDRESS NUMBER IDENTIFIES REMOTE OSI ADDRESS

The OSI address number given in the command identifies a remote OSI address.

10230 FILE CONFLICT ERROR

It has been detected that the files in two different computer units contain contradictory information. See alarm 2065 FILE CONFLICT ERROR.

10231 MAXIMUM NUMBER OF ADDRESSES CONNECTED TO APPLICA-TION

The maximum number of OSI addresses have already been connected to the OSI application.

10232 INVALID LOAD MODULE LENGTH

The length of the load module can not be divided by four.

10233 GIVEN AET IDENTIFIES LOCAL APPLICATION

The AET given in the command identifies a local application.

10234 NONEXISTENT ALARM

The alarm in question is undefined in the alarm system.

10235 NOT CANCELLABLE ALARM

The alarm in question can not be cancelled by the operator.

10236 ALARM BLOCKING IN QUESTION IS ALREADY SET

The same or corresponding alarm blocking is already set.

10237 ALARM BLOCKING IN QUESTION IS NOT SET

The alarm blocking in question is not set.

10238 RELATIONSHIP DOES NOT EXIST

The relationship does not exist.

10239 RELATIONSHIP ALREADY EXISTS

The relationship already exists.

10240 PRINTING ALREADY BLOCKED

Page 90: DX Error Messages

90 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Printing of alarms belonging to the alarm urgency class in question is already prevented.

10241 PRINTING NOT BLOCKED

Printing of alarms belonging to the alarm urgency class in question is not prevented.

10242 PHYSICAL CHANNEL DOES NOT EXIST

The physical channel does not exist.

10243 SOWADM NOT READY

SOWADM has not yet received a starting message from USAPRO.

10244 DATA NOT UPDATED

The identifier of the package in the unit has not been updated in the UNPACK file.

10245 NO ACTION

The task has not been performed.

10246 NO SUCH VERSION

The version can not be found.

10247 DELETING FAILED

The deletion of a disk file has failed.

10248 LOAD MODULE LENGTH ERROR

The load module is too short.

10249 MAFILE NOT OK

The MAFILE file is not in order on either disks.

10250 CHANGE OF ACTIVE VERSION FAILED

The changing of the default version of a disk file has failed.

10251 PHYSICAL CHANNEL GROUP ALREADY EXISTS

The physical channel group already exists.

10252 VIRTUAL CIRCUIT NUMBER USED BY GIVEN PHYSICAL CHANNEL NUMBER

The virtual circuit number is already used on the given physical channel in the given channel group.

10253 PHYSICAL CHANNEL IS NOT LOCKED

The physical channel is not set in the LOCKED state.

10254 PHYSICAL CHANNEL GROUP NAME ALREADY RESERVED

The name of the physical channel group is already in use.

10255 MAXIMUM NUMBER OF PHYSICAL CHANNELS CREATED TO GIVEN CHANNEL GROUP

The maximum number of physical channels has already been created to the given channel group.

10256 PHYSICAL CHANNEL NOT IN GIVEN CHANNEL GROUP

The physical channel does not belong to the given channel group.

10257 ONLY ONE PHYSICAL CHANNEL IN CHANNEL GROUP

Page 91: DX Error Messages

DN987378Issue 24-0

91

General Error Messages of System DX error messages

Id:0900d8058077e097

An attempt has been made to remove the last physical channel from the physical channel group.

10258 ET UNIT NOT IN WORKING STATE

The state of the ET unit is not WO-EX.

10259 TRANSACTION COMMITTED

The transaction has been executed successfully and committed to, but then the transaction hand has failed. The special hand Raveller has ful-filled the job.

10260 ERROR IN DBFILS FILE

The contents of the DBFILS file of the database in question are errone-ous.

10261 ERROR IN DBSMAN PROGRAM BLOCK OF DATABASE SYSTEM

The operator has asked for database loading but the DBSMAN program block does not reply to the load request sent by the database manager.

10262 CONFLICT WITH PPSUBR FILE

A conflict with the local payphone line supervision file (PPSUBR) has been detected.

10263 ERROR IN BUFFER TRANSFER SERVICE (BUFFER IS LOST)

The error may occur when using the asynchronous buffer transfer service SEND_DATA_IN_BUF_ASYNC (the MOVIES library). The fault is a result of the situation in which the application has given the buffer to the MOPSUS family and that the commucation between the MOPSUS family and the application breaks before the connection was released. The fault is highly improbable.

10264 ERROR IN READING APFILE FILE

The reading of the application file of the network operator (APFILE) has failed.

10265 ERROR IN WRITING INTO APFILE FILE

The writing into the application file of the network operator (APFILE) has failed.

10266 ERROR IN READING NEUSER FILE

The reading of the network user file (NEUSER) has failed.

10267 ERROR IN WRITING INTO NEUSER FILE

The writing into the network user file (NEUSER) has failed.

10268 ERROR IN READING AFROFI FILE

The reading of the application field id and process family id file (AFROFI) has failed.

10269 APPLICATION FIELD ALREADY EXISTS

An attempt has been made to add a privilege to the application field to which the user already has a privilege.

10270 NETWORK USER DOES NOT EXIST

The network user identifier does not exist.

Page 92: DX Error Messages

92 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10271 NETWORK USER ALREADY EXISTS

An attempt has been made to add a network user identifier which already exists.

10272 INVALID USER IDENTIFICATION

The user identification is either not a network user id, or the given password is not correct.

10273 INQUIRY NOT COMPLETED

The inquiry, the answer of which requires several messages, is not completed. The error message is the value of the status field of an other than the last message

10274 RULE ALREADY EXISTS

The rule, which is being added into a rulebase, already exists in this rulebase.

10275 DISK UPDATES ARE PREVENTED IN THIS DATABASE

The operator has prevented disk updates. However, he asks the database system to dump the database onto disk.

10276 APPLICATION ENTITY TITLE ALREADY RESERVED

The AET is already used by an application.

10277 GIVEN APPLICATION ENTITY TITLE IDENTIFIES REMOTE APPLI-CATION

The application entity title (AET) given in the command identifies a remote application. Only the application entity title has been defined for the remote application.

10278 GIVEN APPLICATION ENTITY TITLE IDENTIFIES LOCAL APPLICA-TION

The application entity title (AET) given in the command identifies a local application.

10279 NO RESPONSE FROM IOMANA

The TEXTPR program block has sent a task to the IOMANA program block which has not responded within the time limit.

10280 ERROR IN DATABASE ADDRESS

The database address is incorrect.

10281 COMMUNICATION ERROR BETWEEN O7MANA AND O7AMAN

Communication between O7MANA and O7AMAN program blocks has failed.

10282 ANALOG TERMINAL NOT FOUND FROM ATFILE

The analog terminal device marked in the physical channel file (OPCFIL) is not found from the analog data terminal file (ATFILE).

10283 PHYSICAL CHANNEL ALREADY EXISTS

Physical channel already exists.

10284 PHYSICAL TERMINAL DOES NOT EXIST

Page 93: DX Error Messages

DN987378Issue 24-0

93

General Error Messages of System DX error messages

Id:0900d8058077e097

There is no free physical terminal in the computer unit. The analog ter-minals have been listed in the ATFILE file, and the digital ones in the MUFILE file.

10285 PHYSICAL TERMINAL ALREADY RESERVED

The physical terminal is already used by a physical channel.

10286 X25 PARAMETER SET DOES NOT EXIST

The given X25 parameter set is not found from the OPHX25 file.

10287 X25 PARAMETER SET NOT FOUND

The X25 parameter set marked in the physical channel file (OPCFIL) is not found from the OPHX25 file.

10288 PHYSICAL CHANNEL USES DIGITAL TERMINAL

The physical channel uses a digital terminal.

10289 PHYSICAL CHANNEL USES ANALOG TERMINAL

The physical channel uses an analog terminal.

10290 LI2M CONNECTION OFF

Measurement of a multiplexer subscriber line fails. In error situations in 2M connections, SSPPGM program block responds with a congestion in the descending direction.

10291 ERROR BETWEEN MUX AND SUB

Measurement of the multiplexer subscriber line fails. Communication between MUX and SUB-C failed.

10292 INCORRECT TIME SLOT

Measurement of the multiplexer subscriber line fails. The time slot has to be less than 32.

10293 WRONG OR ERRONEOUS OPERAND IN WATSON FILE

In the checks of the WATSON file, there is an operand that is of a wrong type or otherwise incorrect.

10294 UNDEFINED OPERATION IN WATSON FILE

The check definition in the WATSON file is incorrect.

10295 VALUE IN DISK FILE IS INCONSISTENT WITH THE DEFINITION IN WATSON FILE

The contents of the disk file do not meet the validity requirements defined for it.

10296 CHECKING OF DISK FILE EXCEEDS DATA AREA LIMIT

The check defined in the WATSON file in incorrect in that the reference to the file to be checked is directed outside the data area.

10297 PREVIOUS LOGBUFFER SAVE FAILED

Saving of the previous logbuffer has failed.

10298 DISK WRITE FAILURE

Writing into the disk file does not succeed.

10299 EIOLIB: AREA TOO SMALL

Page 94: DX Error Messages

94 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The pointer given to the EIOLIB-program block points to a memory segment that is too small. The execution of the task would lead to a memory protection error.

10300 MESSAGE BUFFER ALLOCATION ERROR

The EIOLIB program block could not allocate a message buffer for a task message.

10301 WRONG REPLY

The EIOLIB program block has received an incorrect reply from the EIDPRO program block.

10302 EIDPRO PROGRAM BLOCK NOT ACCESSABLE

No connection can be made to the EIDPRO program block in a computer with disk.

10303 ACKNOWLEDGEMENT TIME-OUT

The acknowledgement of a successful writing task has ended up in time-out.

10304 INVALID TASK IDENTIFICATION

The task identification in the task message of the EIDPRO program block is incorrect.

10305 INVALID COMPUTER ADDRESS

The unit address given to the EIOLIB program block is either a broad-cast address or a logical address with distribution extent WO+SP.

10306 NO SUCH DEVICE IN UNIT

The unit does not have the desired peripheral device, or the DSKLIB program block is not in use.

10307 WRITING IN DIRECTORY FILE NOT ALLOWED

An attempt has been made to write in a file that is a directory.

10308 CONFLICT BETWEEN NETWORK ELEMENT INDEXES

There is a conflict between network element indexes.

10309 REQUESTED TASK ALREADY DONE

Operator has asked some task to be done by database system but the task has alredy been done.

10310 PLUG-IN UNIT DOES NOT RESPOND

The plug-in unit does not respond.

10311 O7AMAN DOES NOT RESPOND

The OSI address and routing program block (O7AMAN) does not respond.

10312 PLUG-IN UNIT PARAMETERS ARE INCONSISTENT

The plug-in unit parameters are inconsistent.

10313 ODCMAN HAS BEEN REQUESTED ILLEGAL PLUG-IN UNIT STATE TRANSITION

ODCMAN program block has been requested an illegal plug-in unit state transition.

Page 95: DX Error Messages

DN987378Issue 24-0

95

General Error Messages of System DX error messages

Id:0900d8058077e097

10314 HAND INITIALIZATION HAS FAILED

A hand initialization has failed.

10315 INITIALIZATION OF ALL HANDS HAS FAILED

The initialization of all hands has failed.

10316 HAND HAS FAILED

A hand has failed.

10317 FILE OPENING HAS FAILED

A file opening has failed.

10318 NO APPROPRIATE INTERFACE TASK FOR VOPS MESSAGE

There is not an appropriate interface task for the VOPS message.

10319 VOPS PROCESS IS OUT OF MEMORY

A VOPS process is out of memory.

10320 TOO BIG MEMORY ALLOCATION REQUEST BY VOPS PROCESS

A VOPS process has made a too big memory allocation request.

10321 NO CHANNELS AVAILABLE IN CHANNEL GROUP

The outgoing call is rejected because all potential channels are either locked or out of order.

10322 NO LOCAL ADDRESSES AVAILABLE FOR OUTGOING CALL

The outgoing call is rejected because there is no proper local address for the possible channels. Check the administrative and the functional state of the local addresses. Check also the possible address restric-tions of the channels belonging to the selected channel groups.

10323 UNABLE TO SOLVE OUTGOING CALL

The outgoing call is rejected because no proper channel is available to the destination. Check the administrative and the functional state of the channels belonging to the channel groups used by the remote end application.

10324 REMOTE NSAP NOT FOUND IN FILE OADFIL

The call is rejected because the remote NSAP is not found in the address database. Check from the address database that the address is correct.

10325 LOCAL NSAP NOT FOUND IN FILE OADFIL

The call is rejected because the local NSAP is not found in the address database. Check from the address database that the address is correct.

10326 LOCAL SSAP NOT FOUND IN FILE OADFIL

The call is rejected because the local SSAP is not found in the address database. Check from the address database that the address is correct.

10327 LOCAL PSAP NOT FOUND IN FILE OADFIL

Page 96: DX Error Messages

96 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The call is rejected because the local PSAP is not found in the address database. Check from the address database that the address is correct.

10328 LOCAL NSAP NOT IN USE

The call is rejected because the administrative state of the channel is LOCKED. Check if this is necessary.

10329 LOCAL PSAP NOT IN USE

The call is rejected because the administrative state of the address is LOCKED. Check if this is necessary.

10330 WRONG ADDRESS TYPE IN FILE OADFIL

There is a conflict between the address and the application database. The type of the address and the type of the owner of the address mis-match.

10331 INVALID REFERENCE TO FILE OADFIL

There is a conflict between the address and the application database.

10332 INVALID REFERENCE TO FILE OPCFIL

There is a conflict between the channel and the channel group data-base.

10333 INVALID REFERENCE TO FILE OAPFIL

There is a conflict between the address and the application database.

10334 INVALID REFERENCE TO FILE OCGFIL

There is a conflict between the address and the channel group data-base.

10335 INVALID REFERENCE TO FILE OOAFIL

There is a conflict between the address and the application parameter database.

10336 INVALID REFERENCE TO FILE OAEFIL

There is a conflict between the address and the Application Entity Title database.

10337 INVALID REFERENCE TO FILE OCSFIL

Internal error in the current sessions database handling. Out of free records.

10338 REFERENCE TO AN UNALLOCATED RECORD IN FILE OADFIL

There is conflict between application/access control and address data-base. Check the configuration information.

10339 REFERENCE TO AN UNALLOCATED RECORD IN FILE OAPFIL

There is a conflict between the application and the address database. Check the configuration information.

10340 REFERENCE TO AN UNALLOCATED RECORD IN FILE OCGFIL

There is a conflict between the address and the channel group data-base. Check the configuration information.

10341 REFERENCE TO AN UNALLOCATED RECORD IN FILE OPCFIL

Page 97: DX Error Messages

DN987378Issue 24-0

97

General Error Messages of System DX error messages

Id:0900d8058077e097

There is conflict between the channel group and the channel database. Check the configuration.

10342 REFERENCE TO AN UNALLOCATED RECORD IN FILE OOAFIL

The call is rejected because there is a conflict between the address and the application parameter database. Check the configuration informa-tion.

10343 REFERENCE TO AN UNALLOCATED RECORD IN FILE OAEFIL

The call is rejected because there is a conflict between the address and the Application Entity Title database. Check the configuration informa-tion.

10344 WRONG APPLICATION TYPE IN FILE OAPFIL

The incoming call is rejected because there is a conflict between the type of the address and the type of the owner of the address. Check the contents of the application and the address database.

10345 FILE OCGFIL DOES NOT CONTAIN THIS CHANNEL GROUP NAME

The outgoing call is rejected because the channel group name is not found in the channel group database. Check the configuration informa-tion.

10346 FILE OAPFIL DOES NOT CONTAIN THIS LOCAL APPLICATION NAME

The calling local application is not found in the application database. Check the configuration information.

10347 FILE OAPFIL DOES NOT CONTAIN THIS REMOTE APPLICATION NAME

The calling remote end application is not found in the application data-base. Check the configuration information.

10348 FILE OADFIL DOES NOT CONTAIN THIS REMOTE PSAP

The calling remote end PSAP is not found in the address database. Check the configuration information.

10349 NUMBER OF AS7 PLUG-IN UNIT NOT IN MUFILE

The number of the plug-in unit is incorrect.

10350 NUMBER OF AS7 PLUG-IN UNIT NOT IN NECONF

The number of plug-in unit is incorrect.

10351 NUMBER OF CHANNEL NOT IN NECONF

The number of channel is incorrect.

10352 ILLEGAL NUMBER OF CHANNEL

The number of channel is incorrect.

10353 PHYSICAL CHANNEL IS ASSOCIATED TO PHYSICAL CHANNEL GROUP

The physical channel has been associated with a physical channel group.

10354 ACTIVE PCM-TSL ALREADY RESERVED

The active PCM TSL is already reserved.

Page 98: DX Error Messages

98 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10355 PASSIVE PCM-TSL ALREADY RESERVED

The passive PCM TSL is already reserved.

10356 DISK FILE COPYING FAILED

Too many errors occurred in disk file copying, so the copying is inter-rupted.

10357 DATA BLOCK INCORRECT

The data block structure is not as agreed. The records are too short, too long, or their lengths do not match with the length of the data block.

10358 PBX INTERFACE NAME EXISTENT

The name of the PBX interface already exists.

10359 PBX INTERFACE NAME NONEXISTENT

The name of the PBX interface does not exist.

10360 NOT ROTARY DIALLING TELEPHONE

The phone is not a rotary dialling phone in the central memory (CM). The operation failed.

10361 MOVIES LIBRARY NOT AVAILABLE IN UNIT WITH DISK

The EIOLIB library fails in a task requiring data transfer because there is no MOVIES library available in a unit with disk.

10362 MOVIES NOT AVAILABLE IN OWN UNIT

The EIOLIB library fails in a task requiring data transfer because there is no MOVIES library available in its own unit.

10363 NO ASS CHANNELS FOR LTEST PLUG-IN UNITS AVAILABLE IN PCMCON

No ASS channels for the LTEST plug-in units are available in the PCMCON file. The operation failed.

10364 PHYSICAL CHANNEL IS NOT IN UNL-DIS STATE

The physical channel is not in the UNLOCKED-DISABLED state.

10365 PHYSICAL CHANNEL IS NOT IN UNLOCKED STATE

The physical channel is not in the UNLOCKED state.

10366 PHYSICAL CHANNEL IS ALREADY IN LOCKED STATE

The physical channel is already in the LOCKED state.

10367 PHYSICAL CHANNEL IS NOT IN LOCKED STATE

The physical channel is not in the LOCKED state.

10368 NO ROOM FOR DATA AREA

There is not enough space in the memory for the data area to be reserved.

10369 NO SWI PCMS

The amount of SWI PCMs is out of the ordinary.

10370 NO OWN COMSIG EXTERNAL PCMS IN USE

The own COMSIG program block has no external PCMs in use.

10371 MODULE NOT IDENTICAL ON BOTH DISKS

Page 99: DX Error Messages

DN987378Issue 24-0

99

General Error Messages of System DX error messages

Id:0900d8058077e097

The contents of the load module are not identical on the two hard disks.

10372 FILE ERROR IN SNMCSE

An error has occurred when processing a file in SNMCSE program block.

10373 TIMEOUT IN SNMCSE

A timeout has occurred in SNMCSE program block.

10374 CONNECTION FAILURE IN SNMCSE

The connection tried by SNMCSE program block has failed.

10375 UNSUCCESSFUL SNMCSE TASK

A task executed by SNMCSE program block has failed because of the environment.

10376 SYSTEM NAME ALREADY USED BY GIVEN NAME

The system name is incorrect.

10377 SYSTEM IDENTIFIER ALREADY USED BY GIVEN C-NUMBER

The system identifier is incorrect.

10378 NO FREE DISKFILES

There are no free files available on the disk for detailed charging storing.

10379 OSI ADDRESS IS NOT IN UNL-DIS STATE

The OSI address is not in the UNLOCKED-DISABLED state.

10380 OSI ADDRESS IS ALREADY IN LOCKED STATE

The OSI address is already in the LOCKED state.

10381 OSI ADDRESS STATE CHANGE FAILED

Changing the state of the OSI address failed.

10382 INCORRECT DATA IN OSCFIL FILE

The OSCFIL file contains incorrect data when compared to the OPCFIL file. See alarm 2261 CONFLICT BETWEEN TWO FILES.

10383 D-CHANNEL FOR SUBSCRIBER MODULE DOES NOT EXIST

No D-channel for the subscriber module does exist.

10384 D-CHANNEL FOR SUBSCRIBER MODULE ALREADY EXISTS

A D-channel for the subscriber module already exists.

10385 PXNETM NOT IN ACTIVE STATE

The PXNETM program block is not in active working state.

10386 NO FREE TERMINAL FUNCTIONS AVAILABLE

No free terminal functions in AS7U are available.

10387 PCM/TSL ALREADY USED IN OTHER D-CHANNEL

The PCM/TSL is already used in another D-channel.

10388 COMMUNICATION ERROR BETWEEN PXADMI AND OTHER PROGRAM BLOCK

A communication error between PXADMI and some other program block. See PROCESS_COMMUNICATION_ERROR failure flag.

Page 100: DX Error Messages

100 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10389 AS7U TERMINAL NOT INITIALIZED

The AS7U terminal was not initialized.

10390 PAD CONNECTION FAILED

The PAD-connection function has returned an error in status.

10391 PAD COMMUNICATION FAILURE

The PAD-communication function has returned an error in status.

10392 DSP PROGRAM NOT FOUND IN SOFTWARE PACKAGE OF MFST PLUG-IN UNIT

The requested program of the DSP (Data Signalling Processor) is not found in the memory of the 80186 processor when loading a program code of the DSP from the memory of the 80186 processor to the external memory of the DSP.

10393 DATA SIGNALLING PROCESSOR CODE RAM WRITE ERROR

Writing in the program memory (external RAM memory of the DSP) of the DSP in the MFST plug-in unit does not succeed when loading program code into the DSP. The reason for the failure may be a faulty plug-in unit or an incorrect program package of the MFST plug-in unit.

10394 ILLEGAL DSP PROGRAM TYPE

The type of the data signalling processor (DSP) program is illegal.

10395 DATA SIGNALLING PROCESSOR STATE CHANGE FAILED

The state change of a data signalling processor (DSP) has failed in theMFST plug-in unit.

10396 PARAMETER VALUE REQUIRED FOR INITIALIZATION MFST HW IS INCORRECT

The value of a parameter given in MFST_INIT_PARAMETERS message is incorrect.

10397 NO ACKNOWLEDGEMENT TO DSP CODE LOAD REQUEST

No acknowledgement to a LOAD_CMD_DSP_PROGRAMS message is received from the MFLOAD program block in the MFST plug-in unit.

10398 ILLEGAL NUMBER OF SYSTEM

The number of system is incorrect.

10399 ILLEGAL NAME OF SYSTEM

The name of system is incorrect.

10400 NUMBER OF MFST CHANNEL IS INCORRECT

The number of an MFST channel is incorrect.

10401 ATTEMPT TO USE UNUSED MFST CHANNEL

An attempt has been made to use an uninitialized MFST channel in the MFST plug-in unit.

10402 ATTEMPT TO USE UNIMPLEMENTED SIGNALLING TYPE IN MFST

An attempt has been made to use an unimplemented signalling type in an MFST plug-in unit.

Page 101: DX Error Messages

DN987378Issue 24-0

101

General Error Messages of System DX error messages

Id:0900d8058077e097

10403 CONFLICT WITH INITIALIZED AND REQUESTED SIGNALLING TYPE

The requested signalling type is different from the initialized signalling type in an MFST channel in an MFST plug-in unit.

10404 ATTEMPT TO OPEN ALREADY OPENED MFST CHANNEL

An attempt has been made to open an MFST channel that was already opened.

10405 ATTEMPT TO CLOSE UNOPENED MFST CHANNEL

An attempt has been made to close an MFST channel that was not opened.

10406 GIVEN FILE NOT FOUND IN THE MEFILE OF SOURCE DIRECTORY

The name or the identification number of the given file is not found in the MEFILE of the source directory.

10407 GIVEN FILE NOT FOUND IN THE MEFILE OF DESTINATION DIREC-TORY

The name or the identification number of the given file is not found in the MEFILE of the destination directory.

10408 FILE MEFILE DOES NOT EXIST IN SOURCE DIRECTORY

File MEFILE does not exist in the source directory.

10409 FILE MEFILE DOES NOT EXIST IN DESTINATION DIRECTORY

File MEFILE does not exist in the destination directory.

10410 ERROR OCCURRED WHEN READING FILE MEFILE IN SOURCE DIRECTORY

An error occurred when reading file MEFILE in the source directory.

10411 ERROR OCCURRED WHEN READING FILE MEFILE IN DESTINA-TION DIRECTORY

An error occurred when reading file MEFILE in the destination directory.

10412 ERROR OCCURRED WHEN READING FILE DXPFIL IN DESTINA-TION DIRECTORY

An error occurred when reading file DXPFIL in the destination directory.

10413 ERROR OCCURRED WHEN READING FILE DXPFIL IN SOURCE DIRECTORY

An error occurred when reading file DXPFIL in the source directory.

10414 FILE DXPFIL DOES NOT EXIST IN SOURCE DIRECTROY

File DXPFIL does not exist in the source directory.

10415 FILE DXPFIL DOES NOT EXIST IN DESTINATION DIRECTORY

File DXPFIL does not exist in the destination directory.

10416 GIVEN FILE NOT FOUND IN THE DXPFIL OF SOURCE DIRECTORY

The name or the identification number of the given file is not found in the DXPFIL of the source directory.

10417 GIVEN FILE NOT FOUND IN THE DXPFIL OF DESTINATION DIREC-TORY

Page 102: DX Error Messages

102 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The name or the identification number of the given file is not found in the DXPFIL of the destination directory.

10418 GIVEN FILE NOT FOUND IN THE MAFILE OF DESTINATION DIREC-TORY

The name or the identification number of the given file is not found in the MAFILE of the destination directory.

10419 FILE MAFILE DOES NOT EXIST IN DESTINATION DIRECTORY

File MAFILE does not exist in the destination directory.

10420 ERROR OCCURRED WHEN READING FILE MAFILE IN DESTINA-TION DIRECTORY

An error occurred when reading file MAFILE in the destination directory.

10421 ERROR OCCURRED WHEN READING FILE FILCAT IN SOURCE DIRECTORY

An error occurred when reading file FILCAT in the source directory.

10422 FILE FILCAT DOES NOT EXIST IN SOURCE DIRECTORY

File FILCAT does not exist in the source directory.

10423 GIVEN FILE NOT FOUND IN THE FILCAT OF SOURCE DIRECTORY

The name or the identification number of the given file is not found in the FILCAT of the source directory.

10424 GIVEN FILE NOT FOUND IN THE GINTON OF SOURCE DIREC-TORY

The name or the identification number of the given file is not found in the GINTON of the source directory.

10425 FILE GINTON DOES NOT EXIST IN SOURCE DIRECTROY

File GINTON does not exist in the source directory.

10426 ERROR OCCURRED WHEN READING FILE GINTON IN SOURCE DIRECTORY

An error occurred when reading file GINTON in the source directory.

10427 PERMANENT VIRTUAL CIRCUIT IS NOT DEFINED IN X25 PARAM-ETER SET

The permanent virtual channel (PVC) has not been defined in the X25 parameter set (file OPHX25) used by the physical channel.

10428 CIRCUIT STATE CHANGE LOCAL

Circuit state in co-exchange is unknown.

10429 NO FREE DATA TERMINALS IN COMPUTER UNIT

There are no free data terminals in the computer unit.

10430 X25 PARAMETER SET ALREADY EXISTS

The X25 parameter set already exists.

10431 PHYSICAL CHANNEL IS ASSOCIATED TO X25 PARAMETER SET

The physical channel is associated to the X25 parameter set.

10432 UNLOCKED PHYSICAL CHANNEL IS ASSOCIATED TO X25 PARAM-ETER SET

Page 103: DX Error Messages

DN987378Issue 24-0

103

General Error Messages of System DX error messages

Id:0900d8058077e097

The X25 parameter set is associated to the physical channel which is in the UNLOCKED state.

10433 DSP SUPERVISION FLAG CLEARING ERROR

The supervision program block of the DSP (Data Signalling processor) has found that the DSP does not clear the supervision flag.

10434 O&M CONNECTION NOT AVAILABLE

External messages cannot be sent. Check the O&M connection.

10435 LOW FEED LIMIT

Overload information of the power suply of the subscriber module. The overload is low but it inhibits the measurement.

10436 MEDIUM FEED LIMIT

Overload information of the power suply of the subscriber module. The overload is medium level and it inhibits the measurement.

10437 HIGH FEED LIMIT

Overload information of the power suply of the subscriber module. The overload is high and it inhibits the measurement.

10438 DSP PROGRAM CODE VERIFY ERROR

The supervision function of DSP code has found that the program code of the DSP has changed in the code RAM of the DSP.

10439 LIA COMMUNICATION FAILURE

Communication failure between the LIA10 and SBCN plug-in units.

10440 HOME METERING PULSE CONGESTION

Home metering pulse congestion.

10441 SBLTI COMMUNICATION FAILURE

Communication failure between SBLTI and SBCN plug-in units.

10442 SBLTI BUSY

The SBLTI plug in unit is busy.

10443 SBLTI FAULTY

The SBLTI plug-in unit is faulty.

10444 NO TEST IN SBLTI

There is no test under execution in the SBLTI plug-in unit.

10445 INCOMING CALL

A call is coming in during a test.

10446 LIA TEST CONNECTION TIME LIMIT

Test connection time limit in the LIA10 plug-in unit.

10447 OTHER TEST IS RUNNING IN MODULE

The operation fails. There is another test under execution in the sub-scriber module.

10448 VIRTUAL CIRCUIT NUMBERS ARE NOT COMPATIBLE

Virtual circuit numbers are not compatible. See /X25 Configuration Parameters Handling, Command Manual, 2.6/.

Page 104: DX Error Messages

104 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10449 CONFLICT BETWEEN MAXIMUN NSDU LENGTH AND USER DATA SIZE

Network service data unit length and user data size are not compatible.

10450 REPEATED RESTART IN UNIT

Repeated restart in the ECU/MPC/DIPC/DIC unit.

10451 PREPROCESSOR PROGRAM CHECK SUM ERROR

The check sum of one or more programs is incorrect in the preproces-sor.

10452 PREPROSESSOR START-UP RAM TEST ERROR

The error(s) in the RAM memory of the preprosessor has been found by the start-up RAM test of the preprocessor.

10453 CONFLICT BETWEEN REQUESTED OPERATION AND GIVEN SYSTEM LEVEL

There is a conflict between the requested operation and given system level.

10454 CONFLICT BETWEEN FILE IDENTIFIER AND FILE NAME

There is a conflict between the file identifier and file name.

10455 MEASURING DEVICE NOT FOUND

A measuring device is not found from the configuration file for sub-scriber network measurement interfaces (XMCONF). The reason for this is one of the following: 1. The measuring device is not defined in the file. 2. The device is defined in the file, but the module of the line to be measured is not connected to it. 3. The device is defined in the file and the module of the measured line is connected to it, but the subscribers of the module corresponding to the module type in the subscriber main-tenance information, can not be measured with the measuring device. In this case the fault is either in the central memory maintenance infor-mation or in the XMCONF file.

10456 O&M CHANNEL STATE CHANGE NOT POSSIBLE

The state transition of the operation and maintenance channel is not possible.

10457 O&M CHANNEL NOT IN WORKING STATE

The state of the operation and maintenance channel is incorrect.

10458 LINE NOT DEFINED IN PPSUBR FILE

Data on the line is missing from the local payphone supervision file (PPSUBR). The operation has failed.

10459 MAXIMUM VIRTUAL CIRCUIT NUMBER EXCEEDED

The maximum virtual circuit number has been exceeded. The maximum number is 255.

10460 RESERVATION OF EIDPRO HAND FAILED

All the hands of the EIDPRO process family are reserved, and the res-ervation of a hand does not succeed. This fault situation may occur when there are several disk writings, but it may also be a sign of errors (hands are dead).

Page 105: DX Error Messages

DN987378Issue 24-0

105

General Error Messages of System DX error messages

Id:0900d8058077e097

10461 INITIALIZATION OF HANDS IN EIDPRO PROCESS FAMILY FAILED

The initialization of hands has failed, and the execution of file operations is not possible. The master of the EIDPRO process family sends a reply message with this error message to all disk file operation requests.

10462 D-CHANNEL ALREADY EXISTS

The given D-channel already exists.

10463 D-CHANNEL DOES NOT EXIST

The given D-channel does not exist.

10464 PHYSICAL CHANNEL NOT IN DISABLED STATE

The physical channel is not in the DISABLED state.

10465 PHYSICAL CHANNEL ALREADY IN UNLOCKED STATE

The physical channel is already in the UNLOCKED state.

10466 PHYSICAL CHANNEL IS SHUTTING DOWN

The physical channel is shutting down, and the next administrative state of the physical channel has to be LOCKED.

10467 ANALOG DATA TERMINAL DOES NOT EXIST

The analog data terminal is not found with the given parameters (search key) from the ATFILE file.

10469 DIRECTORY ENTRY DOES NOT EXIST

There is no directory entry for the given object, or no directory entry with the given key value.

10470 ANALOG DATA TERMINAL ALREADY EXISTS

The analog data terminal already exists in the ATFILE file.

10471 GIVEN PLUG-IN UNIT NOT IN MUFILE FILE

The given plug-in unit is not found in the MUFILE file. Use WHP command to add a new plug-in unit.

10472 UNLOCKED PHYSICAL CHANNEL CONNECTED TO ANALOG DATA TERMINAL

An unlocked physical channel is connected to an analog data terminal (physical channel is in UNLOCKED state).

10473 PHYSICAL CHANNEL CONNECTED TO ANALOG DATA TERMINAL

The physical channel is connected to an analog data terminal.

10474 FEED VOLTAGE ERROR

The polarity is incorrect, or the feed is missing totally.

10475 DIRECTORY ENTRY ALREADY EXISTS

The directory entry for an object already exists, or if the directory key is unique, there is already a directory entry with the same key value as in the object to be inserted.

10476 PRIMITIVE ITEM IS INVALID

The operation succeeded completely.

10477 MODE PARAMETER IS INVALID

Page 106: DX Error Messages

106 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The operation succeeded completely.

10478 ERROR PARAMETER IS INVALID

The operation succeeded completely.

10479 OBJECT CLASS PARAMETER IS INVALID

The operation succeeded completely.

10480 OBJECT INSTANCE PARAMETER IS INVALID

The operation succeeded completely.

10481 ATTRIBUTE LIST PARAMETER IS MISSING

The operation succeeded completely.

10482 ATTRIBUTE PARAMETER IS INVALID

The operation succeeded completely.

10483 EVENT IDENTIFIER IS INVALID

The operation succeeded completely.

10484 ACTION IDENTIFIER IS INVALID

The operation succeeded completely.

10485 ATTRIBUTE IDENTIFIER PARAMETER IS INVALID

The operation succeeded completely.

10486 HAND SHAKE MESSAGE NUMBER IS INCORRECT

The operation succeeded completely.

10487 DESTINATION APPLICATION DOES NOT ACCEPT THE DATA TRANSFER

The operation succeeded completely.

10488 HAND SHAKE MESSAGE TYPE IS INVALID

The operation succeeded completely.

10489 APPLICATION DATA RECEIVED IS TOO BIG

The operation succeeded completely.

10490 COMMUNICATION ERROR BETWEEN O7MANA AND DUMPER

Communication between the O7MANA and DUMPER program blocks has failed.

10491 SUBSCRIBER NUMBER NOT FREE

The subscriber number analysis can not be destroyed unless the number is in FREE state.

10492 ILLEGAL TRUNK CODE

The trunk code is incorrect.

10493 UNKNOWN ANALYSIS CASE

The analysis case is unknown.

10494 NO ET FOR ACTIVE PCM

There is no ET for an active PCM.

10495 NO ET FOR SPARE PCM

There is no ET for a spare PCM.

Page 107: DX Error Messages

DN987378Issue 24-0

107

General Error Messages of System DX error messages

Id:0900d8058077e097

10496 O&M CHANNEL NOT IN SEPARATED STATE

The state of the operation and maintenance channel is incorrect.

10497 TRIGGER RECORD NONEXISTENT

The trigger record does not exist.

10498 TRIGGER RECORD EXISTENT

The SPCROU record contains trigger data.

10499 COMMUNICATION FAILURE WITH OTHER UNIT

Message transfer to the adjacent synchronization unit is not possible. This is probably due to a hardware failure either in this or in the adjacent unit, or in the cartridge subrack.

10500 SWITCHOVER FAILURE IN HARDWARE

Switchover was attempted, but it failed in CL1TG/CL2TG. This may be due to a hardware failure in this or the other syncronisation unit or in the cartridge hardware. Check also the position of the forced control switches in both syncronisation units.

10501 STATE CHANGE NOT POSSIBLE DUE TO ACTUAL STATES OF CLS UNITS

State change is not possible, for example from SE-state to SP-state.

10502 DIAGNOSTIC TESTS ON IN CLS UNIT

State change is not possible because there are diagnostic programs running in the syncronization unit

10503 NO CHARGING PARAMETERS

Charging parameters are missing, when there is an Intelligent Network route in special route file and charging index is 0.

10504 INTERNAL CIRCUIT GROUP DOES NOT EXIST

The internal circuit group does not exist.

10505 INTERNAL PCM NOT CONNECTED TO INTERNAL ROUTE

The internal PCM has not been connected to an internal route to which the time slots of the terminal belong.

10506 CIRCUIT GROUP CREATION FAILED

Creation of the internal circuit group failed.

10507 CIRCUIT GROUP DELETION FAILED

Deletion of the internal circuit group failed.

10508 CIRCUIT ADDITION TO CIRCUIT GROUP FAILED

Addition of an internal circuit into an internal circuit group failed.

10509 CIRCUIT DELETION FROM CIRCUIT GROUP FAILED

Deletion of an internal circuit from an internal circuit group failed.

10510 EXTERNAL ROUTING FAILURE

External routing failure.

10511 COMMUNICATION ERROR BETWEEN O7MANA AND CM3PRO PROGRAM BLOCKS

Page 108: DX Error Messages

108 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Communication failure between the O7MANA and CM3PRO program blocks (O7MANA did not receive an answer from CM3PRO before a time-out).

10512 CIRCUIT GROUP UPDATING FAILED

Updating of the data of the routing files of CM3PRO program block failed. Check the routing data with the CGROUP MML (command group RC).

10513 MEASUREMENT DEVICE WAS NOT FOUND

There are no measurement devices defined in the system.

10514 INCORRECT SUBSCRIBER NUMBER IDENTIFICATION

There is not found any subscriber in the database with this identification.

10515 TIMEOUT: NO RESPONSE FROM NETWORK LAYER

PAD software cleared the connection because the network layer (X.25 software) did not respond to messages that were sent to it. It is also possible that the network layer never received the message because sending the message failed at operating system level.

10516 CALL CLEARED BY REQUEST OF REMOTE DTE

PAD software cleared the connection because the remote DTE sent an X.29 invitation-to-clear message. This is considered to be the normal way to end a PAD session.

10517 NETWORK DISCONNECT INDICATION RECEIVED

The connection has been cleared either by the network layer software or the remote DTE.

10518 TOO SMALL CREDIT GRANTED BY NETWORK LAYER

Each data message that the PAD software sends to the network layer decreases its credit by 128 (or more) bytes. The reason for disconnect-ing was that the initial credit granted by the network layer was too small to send any data messages at all.

10519 HARDWARE ALARM ON IN SYNCRONISATION UNIT

Switchover is prohibited by a hardware alarm in the synchronization unit.

10520 NO RESPONSE FROM SPARE SYNCRONISATION UNIT

Switchover is not possible because the spare synchronization unit does not respond. In the hardware the switchover command is executed in the spare unit.

10521 MAFILE CORRESPONDING TO PAID NOT FOUND

The MAFILE file corresponding to the package identifier is not found.

10522 MODULE EXISTS IN LOADLIST BUT NOT IN MAFILE

The module listed in the load list is not found in the MAFILE file.

10523 INCORRECT DATA IN CS7PAR FILE

Incorrect data in CS7PAR file detected. For further information, see alarm 2077 (CCS7 PROGRAM BLOCK DATA FAILURE) and/or LOG FILE UTILITY.

Page 109: DX Error Messages

DN987378Issue 24-0

109

General Error Messages of System DX error messages

Id:0900d8058077e097

10524 INCORRECT SUBSCRIBER TYPE

The subscriber type (e.g. analog/ISDN) indicates, which facilities are possible in each case. Part of the facilities are type-dependent. If an attempt is made to set a pure ISDN facility to an analog subscriber, this ends in an error situation.

10525 THIS MML TASK NOT ALLOWED AT THE MOMENT

This MML task is not allowed at this MML terminal at the moment because it or some other MML task close to this one is activated from another MML terminal at the same time. Try again later.

10526 ERROR COUNTER LIMIT EXCEEDED

Error counter limit has been exceeded.

10527 TRUNK CODE EXISTENT

The trunk code already exists.

10528 TRUNK CODE NONEXISTENT

The trunk code does not exist.

10529 TRUNK CODE SHORTER

The existing trunk code is shorter than the given trunk code.

10530 TRUNK CODE LONGER

The existing trunk code is longer than the given trunk code.

10531 EXTENSION IN CENTREX HUNTING GROUP

The subscriber is a member of a Centrex hunting group.

10532 SUBSCRIBER HAS NO MULTIPLE SUBSCRIBER NUMBERS

The subscriber has no multiple subscriber numbers.

10533 SUBSCRIBER HAS ALL MULTIPLE NUMBERS IN USE

A subscriber is allowed to have 8 multiple subscriber numbers. If this is exceeded, an error notice is given.

10534 INCORRECT CENTREX GROUP

You can only belong to a Centrex hunting group if you are a member of the same Centrex group.

10535 RSU SUBSCRIBER

The subscriber number is reserved for a RSU subscriber.

10536 RELATIONSHIP DOES NOT HOLD IN A SUPERSET FOR THE RELATION

A relationship is to be added in a relation but the relationship does not hold in some superset of the relation.

10537 PHYSICAL CHANNEL CONNECTED TO DIGITAL DATA TERMINAL

The physical channel is connected to a digital data terminal. Remove physical channel before deleting digital data terminal.

10538 BSC OBJECT NOT FOUND IN RNW DATABASE

The Base Station Controller has not been created into the RNW data-base.No other objects can be created before the BSC object has been created.

Page 110: DX Error Messages

110 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10539 BCF OBJECT NOT FOUND IN RNW DATABASE

The Base Control Function object has not been created into the data-base. There must be an existing BCF under which a Base Station object can be created.

10540 BTS NOT FOUND IN RNW DATABASE

The Base Station has not been created into the RNW database. There must be an existing BTS under which a Tranceiver, a Frequency Hopping System or an Adjacent Cell object can be created.

10541 TRX NOT FOUND IN RNW DATABASE

The Tranceiver has not been created into the RNW database. There must be an existing TRX under which a Radio Timeslot can be created.

10542 RADIO TSL NOT FOUND IN RNW DATABASE

The Radio Timeslot has not been created into the RNW database.

10543 HOPPING SYSTEM NOT FOUND IN RNW DATABASE

The Frequency Hopping System has not been created into the RNW database. There must be an existing FHS into which a hopping Radio Timeslot can be connected.

10544 ADJACENT CELL WAS NOT FOUND IN RNW DATABASE

The Adjacent Cell has not been created into the RNW database.

10545 OBJECT WAS NOT CREATED

The database system has not succeeded in creating a new object.

10546 END OF LOAD GROUP

End of load group was encountered.

10547 INTERNAL PCM IS NOT CONNECTED TO CIRCUIT GROUP NAMED OSIAS7

The internal PCM has not been connected to an internal circuit group to which the time slots of the terminal belong. Name of the internal circuit group of the X.25 terminal is OSIAS7.

10548 MAXIMUM NUMBER OF ADJACENT CELLS FOR ONE BASE STATION EXCEEDED

One base station may have only a limited number of neighbours. This number can not be exceeded.

10549 SOME BCF STILL EXISTS

There still are some Base Control Function objects under the BSC to be deleted. All the objects under the BSC must be deleted before deleting the BSC itself.

10550 SOME BTS STILL EXISTS

There are still Base Station objects under the BCF to be deleted. All the objects under the BCF must be deleted before deleting the BCF.

10551 FREQUENCY HOPPING SYSTEM IS IN USE

Frequency Hopping System is still used by some radio timeslots. It can not be deleted before all the relations between the FHS and radio timeslot objects are removed.

Page 111: DX Error Messages

DN987378Issue 24-0

111

General Error Messages of System DX error messages

Id:0900d8058077e097

10552 HUNTING GROUP CALL NUMBER

A notice related to subscriber handling - inquiry, creation, or deletion. The notice means that the subscriber is a hunting group call number.

10554 PARAMETERS OF MAC FRAME SENT TO ETHERNET DRIVER WERE ERRONEOUS

The parameters of the MAC frame sent to the Ethernet driver were erroneous.

10555 ETHERNET DRIVER IS NOT READY TO SEND MAC FRAMES TO ETHERNET

The Ethernet driver is not ready to send MAC frames to the Ethernet.

10556 TOO MANY PACKETS RECEIVED FROM ETHERNET

The OISOIP program block cannot send the packets received from the Ethernet to the network service user because of the lack of the credit.

10557 MEMORY FILE UPDATES ARE FORBIDDEN.

Memory files should not be updated at the moment.

10558 PHYSICAL DATA TERMINAL NOT FOUND

Physical terminal of the channel is not found in the OSCFIL file. Check the data of OSCFIL and OPCFIL files on the manipulated channel.

10559 NOT A HUNTING GROUP CALL NUMBER

The call number given by the user is not a group call number known by the hunting group handling MML (SUHARI).

10560 SOWADM TIME-OUT

No response is received from the SOWADM program block.

10561 FILE NOT IN UNION FILE

The file is not found in the union file.

10562 MODULE LOADED

All data of the module has already been loaded.

10563 TIME LIMIT EXCEEDED IN SBCN COMMUNICATION

Time limit exceeded in SBCN communication.

10564 VACANT DPABX SUBSCRIBER NUMBER

A free subscriber number found in the 1st or 2nd tree of the digit analy-sis, and created for the use of a DPABX.

10565 RESERVED DPABX SUBSCRIBER NUMBER

The subscriber number is an existing DPABX number.

10566 AREA CODE NOT FOUND

No area code can be found in the parameter file PRFILE with the area_code_id received from the subscriber database.

10567 FILE EXISTS IN LOADLIST BUT NOT IN MEFILE

A file in the load list is not found in the MEFILE file.

10568 SWITCHOVER IN SYNCRONISATION UNIT DURING COMMAND EXECUTION

Page 112: DX Error Messages

112 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Command failed because of a switchower during command execution.

10569 UNEXPECTED CURRENTS IN LINE

In subscriber line measurement, currents of wrong direction were detected. It is possible that there is short circuit or external voltages on the line. The measurement results are not reliable.

10571 NON EXISTENT PIU

The PIU does not exist.

10572 ERROR OCCURRED IN DATABASE CONVERSION

An error has occurred in database conversion. See print-outs and error logs for the cause of the error.

10573 NO MATCHING RULES TO BE DELETED

No rules matching the given parameters are found in the alarm system rulebase. No rules are deleted.

10574 NO MATCHING RULES TO BE MODIFIED

No rules matching the given parameters are found in the alarm system rulebase. No rules are modified.

10575 NO MATCHING RULES TO BE RESTORED

No previously deleted, restorable rules matching the given parameters are found in the alarm system rulebase. No rules can be restored.

10576 BOOT LOADING FAILED

The software package intended for the computer is not available.

10577 PLUG-IN UNIT RESTARTED

Plug-in unit has been restarted.

10578 MISSING INTERFACE PLUG-IN UNIT

Interface plug-in unit is missing.

10580 SEMIPERMANENT CONNECTION

Semipermanent connection.

10581 PLUG-IN UNIT IS IN TEST

Plug-in unit is in test.

10582 MORE THAN 10 MATCHING RULES FOUND

There are more than 10 rules in an alarm system rulebase which match the given parameters. Only the 10 first will be handled.

10583 ILLEGAL INFORMATION FIELD NUMBER

The alarm number given does not have the information field of the given number.

10584 ILLEGAL INFORMATION FIELD SUB NUMBER

The given information field of the given alarm number does not have the sub field of the given number.

10585 DISK FILE VALIDITY CHECKINGS ARE BLOCKED

Disk file validity checkings are temporarily blocked.

10586 ASK FOR MORE ANALYSES

Page 113: DX Error Messages

DN987378Issue 24-0

113

General Error Messages of System DX error messages

Id:0900d8058077e097

There are more analyses to be printed.

10587 ANALYSIS TREE CORRUPTED

Analysis tree is corrupted.

10588 ARF SUBSCRIBER

The subscriber number is in ARF use.

10589 VACANT ARF SUBSCRIBER NUMBER

The result of the subscriber number analysis is a vacant number in ARF tree.

10590 ARF SUBSCRIBER NUMBER RESERVED

The subscriber number is used by an ARF subscriber.

10591 FILE IS IN STABLE STATE

File is in stable state i.e. values of the fields of the file are stable.

10592 FILE IS IN UNSTABLE STATE

File is in unstable state i.e. values of the fields of the file are unstable.

10593 ARF NAME DOES NOT EXIST

The ARF name defined is not found in the file.

10594 RSU NAME DOES NOT EXIST

The RSU name given is not found in the file.

10595 NO SENSE KEY

SCSI-command returns CHECK CONDITION status but in sense data there is no specific sense key information to be reported for the drive.

10596 BLANK CHECK

Blank tape or cassette.

10597 SCSI COMMAND ABORTED

SCSI-command aborted.

10598 ANALYSIS FOR ARF SUBSCRIBER DOES NOT EXIST

The subscriber number analysis for the ARF subscriber is missing.

10599 INCOMPATIBLE SUBSCRIBER NUMBERS

The subscriber numbers given in the MML command are incompatible with each other.

10600 TAPE MEDIUM ERROR

Physical end of tape (PEOT) or synthetic PEOT encountered. Read or write error, probably caused by a flaw in the tape or by a dirty head; replace the cassette or the tape drive. End-of-data not found; drive tries to read a blank or unformatted tape. Block sequence error; a format dis-continuity encountered. Positioning error during read. Incompatible tape installed. Tape format corrupted. Tape length error. Sequential position-ing error. Repositioning error. The last frame of the group not found when appending new data during a write-type operation.

10601 TAPE DRIVE HARDWARE ERROR

The cassette or the tape drive is faulty; replace the cassette or the tape drive. Incompatible tape format. Condensation detected.

Page 114: DX Error Messages

114 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10602 SOURCE DISK NOT OK

Loading cannot be executed because the source disk is not OK.

10603 OBJECT STATE IS INCORRECT

The state of the object in the database is unsuitable for the requested-operation.

10604 ADDRESS IS NOT VALID MULTICAST ADDRESS

The first bit, i.e. the least significant bit of the first byte of the address should be 1.

10605 ADDRESS LIST IS FULL

The address list of Ethernet MAC driver program is full.

10606 ADDRESS IS ALREADY IN LIST

The given multicast address was already in the address list of the Ethernet driver program. The program does not allow duplicate addresses.

10607 ADDRESS IS NOT FOUND IN ADDRESS LIST

The address could not be removed from the multicast address list of theEthernet driver program because it was not there.

10608 ET NOT IN SUPERVISION

ET unit is not in supervision due to the state of the ET.

10609 ILLEGAL SUPPORTING AMOUNT

Field Supporting amount of the message used for adding a supporting rule has illegal value. No rule added.

10610 ALL RECORDS IN USE

All record reserved for certain kind of items are already in use.

10611 RSS MODULEGROUP DOES NOT EXIST

The RSS module group number does not exist.

10612 SUB NOT FOUND

The subscriber module is not found.

10613 SUBSCRIBER MODULE ALREADY EXISTS

The subscriber module already exists.

10614 PCM NOT FOUND

PCM is not found.

10615 PCM ALREADY EXISTS

PCM already exists.

10616 ARRAY OVERFLOW

Array overflow; the array cannot hold all data to be written there.

10617 BTS IS SHUTTING DOWN

Operation is not allowed while BTS is in state SHUTTING DOWN (forced handover).

10618 CONTROL PARAMETERS NOT FOUND IN DATABASE

Page 115: DX Error Messages

DN987378Issue 24-0

115

General Error Messages of System DX error messages

Id:0900d8058077e097

The control parameter set object has not been created into the data-base.

10619 BCF APPLICATION FILE NOT FOUND

BCF application file is not found in the fixed disk of the BSC.

10620 BCF MASTER FILE NOT FOUND

BCF master file is not found in the fixed disk of the BSC.

10621 BCF BUILD ID FAILURE

BCF build id is incorrect.

10622 BCF BUILD DIRECTORY NOT FOUND

BCF build directory is not found in the fixed disk of the BSC.

10623 BCF ID ALREADY EXISTS IN BCF BUILD HANDLING SYSTEM

BCF ID already exists in the BCF build handling system of the BSC.

10624 BCF ID IS NOT FOUND IN BCF BUILD HANDLING SYSTEM

BCF ID is not found in the BCF build handling system of the BSC.

10625 BCF BUILD DIRECTORY IS ALREADY IN USE

BCF build directory on the fixed disk of the BSC is already in use.

10626 BCD BUILD ID ALREADY EXISTS

BCD build has already been created in the BCF package handling system of the BSC.

10627 BCF BUILD ID IS NOT FOUND

BCF build id is not found in the package handling system of the BSC.

10628 BCF BUILD IS ATTACHED TO BCF

BCF build is attached to the status of the BCF.

10629 BCF BUILD ID IS NOT ATTACHED TO BCF

BCF build id is not attached to the status of the BCF.

10630 BTMFIL READ ERROR

Error in reading the BTMFIL file.

10631 BTMFIL WRITE ERROR

Error in writing to the BTMFIL file.

10632 BTPFIL READ ERROR

Error in reading the BTPFIL file.

10633 BTPFIL WRITE ERROR

Error in writing to the BTPFIL file.

10634 BTMFIL FILE IS FULL

The BTMFIL file has no free records.

10635 BTMFIL FILE NOT SAVED TO DISK

The BTMFIL file is not saved to the fixed disk of the BSC.

10636 BTPFIL FILE IS FULL

The BTPFIL file has no free records.

Page 116: DX Error Messages

116 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10637 BTPFIL FILE NOT SAVED TO DISK

The BTPFIL file is not saved to the fixed disk of the BSC.

10638 BCF BUILD HANDLING SYSTEM BUSY (SWADMI PROGRAM BLOCK)

The SWADMI program block cannot create a new hand.

10639 BCF STATUS ALREADY HAS BUILD ATTACHMENT

The BCF status already has a build attachment.

10640 BCF STATUS HAS NO BUILD ATTACHMENT

The BCF status has no build attachment.

10641 BCF BUILD STATUS IS INCORRECT

The BCF build status is incorrect.

10642 DEFAULT BCF BUILD IS NOT FOUND

The default BCF build is not found.

10643 SWADMI HAS RECEIVED NO RESPONSE FROM REQMAN

The SWADMI program block has received no response from the REQMAN program block.

10644 SWADMI HAS RECEIVED NO RESPONSE FROM MEMDAT

The SWADMI program block has received no response from the MEMDAT program block.

10645 NO FR TERMINALS IN USE

FR terminal freezing failed in FRU, because there are no FR terminals in use.

10646 FR TERMINAL FREEZING FAILED PARTLY

Freezing of FR terminals in FRU failed partly.

10647 FR TERMINALS FREEZING FAILED COMPLETELY

Freezing of FR terminals in FRU failed completely.

10648 BCF BUILD ID ALREADY EXISTS

The BCF build has already been created in the BCF build handling system of the BSC.

10649 FRAME RELAY SHORT PERIOD MEASUREMENT ALREADY ACTIVE

An attempt has been made to start a FR short period measurement which already is active.

10650 FRAME RELAY SHORT PERIOD MEASUREMENT ACTIVE

The function fails because the FR short period measurement is active.

10651 FRAME RELAY SHORT PERIOD MEASUREMENT DOES NOT EXIST

The functions fails because the FR short period measurement identified does not exist.

10652 FRAME RELAY SHORT PERIOD MEASUREMENT NOT ACTIVE

The function fails because the FR short period measurement identified is not active.

Page 117: DX Error Messages

DN987378Issue 24-0

117

General Error Messages of System DX error messages

Id:0900d8058077e097

10653 MEASUREMENT OBJECT DOES NOT EXIST

Creating a FR short period measurement failed because one of the objects to be measured does not exist.

10654 MEASUREMENT NAME IS ALREADY USED

Creating the FR short period measurement failed because the mea-surement name is already in use.

10655 NO FREE MEASUREMENT CONTROL DATA SLOTS

Creating the FR short period measurement failed because file FSMCDA contains no free space for the control data of the measurement.

10656 FRAME RELAY STATISTICS STOPPED

The operation failed because the FR statistics has been stopped.

10657 USER ACCESS ALREADY EXISTS

Frame Relay user access already exists.

10658 USER ACCESS DOES NOT EXIST

Frame Relay user access does not exist.

10659 TRUNK ACCESS ALREADY EXISTS

Frame Relay trunk access already exists.

10660 TRUNK ACCESS DOES NOT EXIST

Frame Relay trunk access does not exist.

10661 VIRTUAL CONNECTION ALREADY EXISTS

Frame Relay virtual connection already exists.

10662 VIRTUAL CONNECTION DOES NOT EXIST

Frame Relay virtual connection does not exist.

10663 DLC IS NOT CONFIGURED

An attempt has been made to change the working state of DPNSS cir-cuit(s) from the NU-state up to some other state by using the CEC-command, but the corresponding DLCs (Data Link Connection) are not configured.

10664 BCF RESERVED FOR THE TEST

BCF is already reserved for the test.

10665 PRIMITIVE WAS NOT SENT

NMCOMM was not able to send the primitive due to the malfunction of the OSI-stack.

10666 ERROR IN OPENING FILES IN PROGRAM BLOCK FSHSTA

The operation failed because program block FSHSTA could not open the files needed.

10667 CELL ID IS ILLEGAL OR INCOMPATIBLE

An attempt has been made to use illegal or incompatible cell identifica-tion in radio network object creation.

10668 INCORRECT INDEX TO RSU ROUTES

The index of the RSU ROUTES is incorrect.

Page 118: DX Error Messages

118 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10669 30MIN DATA COLLECTION

Transferring of 30 minute measurement period meters from the distrib-uted part to the centralized part is in progress.

10670 30MIN DATA COLLECTION COMPLETED

Transferring of 30 minute measurement period meters from the distrib-uted part to the centralized part has been completed.

10671 NO METERS FOUND

No meters were found with the given parameters.

10672 STATISTICS STOPPED AND FILES NOT CREATED

Statistics files are not created because the statistics are stopped.

10673 NO METERS DIVERGE FROM NIL

No meters diverging from nil have been found with the given parame-ters.

10674 OMC WAS NOT UPDATED

The change which was made by a local MMI to the BSC database was not updated to the OMC. There is no working link to the OMC at the moment.

10675 BTS O&M LINK OUT OF ORDER

The BTS can not be updated because the O&M link is down.

10676 BTS RECOVERY SYSTEM BUSY (PROGRAM BLOCK BTLARM)

BTS reset acknowledgement message from BTLARM is missing.

10678 FR USER DOES NOT EXIST

FR user does not exist.

10680 INCORRECT DATA BETWEEN D-CHANNEL FILES

One D-channel file contains incorrect data with regard to other D-channel file. See alarm 2261 CONFLICT BETWEEN TWO FILES.

10681 END OF ARRAY

An attempt has been made to write / read from an array position, where there is no data.

10682 UNKNOWN CALL PARAMETER

An unknown call parameter was detected in the called routine.

10683 ET FOR D-CHANNEL DOES NOT EXIST

There is no ET for the D-channel connection.

10684 DATA LINK CONNECTION ALREADY IN USE

The given data link connection value(s) are already in use.

10685 DATA LINK CONNECTION STATES CORRUPTED

The states of data link connection have been corrupted.

10686 DATA LINK CONNECTIONS ALREADY ACTIVATED

The given data link connection values are already activated.

10687 DATA LINK CONNECTIONS ALREADY DEACTIVATED

The given data link connection values already deactivated.

Page 119: DX Error Messages

DN987378Issue 24-0

119

General Error Messages of System DX error messages

Id:0900d8058077e097

10688 DATA LINK CONNECTION NOT DEACTIVATED

The data link connections are not deactivated.

10689 DATA LINK CONNECTIONS DO NOT EXIST

The given data link connection values do not exist.

10690 FIXED LIMITS EXCEEDED IN DATABASE SYSTEM

In the database system, a transaction has tried to exceed the fixed limits (e.g. the number of elements of the search structure). The transaction has been aborted.

10691 GT ANALYSIS NONEXISTENT

IMSI analysis has been created and type of address is global title, but there exists no analysis for this global title.

10692 WSS NOT UPDATED

Data of WSS was not updated.

10693 QNG NOT UPDATED

Data of QNG was not updated.

10694 OPERATOR IDENTIFICATION NOT RESERVED

Operator identification has not been reserved.

10695 OPERATOR IDENTIFICATION RESERVED

Operator identification has been reserved.

10696 OPERATOR NOT LOGGED IN

Operator not LOGGED IN.

10697 OPERATOR NOT LOGGED OUT

Operator not LOGGED OUT.

10698 OPERATOR HAS SERVICEABILITY

Operator has serviceability.

10699 OPERATOR PLACE FREE

Operator place free.

10700 PRIORITY ALREADY USED

Priority already used.

10701 CALL TYPE ALREADY USED

Calltype already used.

10702 INCORRECT OPERATOR SYSTEM NUMBER

Incorrect operator system number.

10703 INCORRECT STAGE NUMBER

Incorrect stage number.

10704 SERVICE HAS OPERATOR

Service has an operator.

10705 SERVICE NAME RESERVED

Service name reserved.

10706 TOO MANY OPERATORS

Page 120: DX Error Messages

120 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Too many operators.

10707 TOO MANY SERVICES

Too many services.

10708 TOO MANY SERVICE NUMBERS

Too many service numbers.

10709 SERVICE NUMBER NAME RESERVED

Service number name reserved.

10710 NUMBER RESERVED FOR SERVICE

Number reserved for service.

10711 NUMBER NOT RESERVED FOR SERVICE

Number not reserved for service.

10712 NONEXISTENT OPERATOR SYSTEM NUMBER

The operator system number does not exist.

10713 NONEXISTENT SERVICE

The service does not exist.

10714 NO SUCH SERVICE NUMBER NAME

There was no such service number name.

10715 NO SERVICE NUMBER

There was no such service number.

10716 NO OPERATORS

No operators.

10717 RECEIVED EVENT DATA IS NOT OK

Data received from the partner program block is out of range.

10718 NO RESERVED RECORD IN THE FILE

The file has no reserved records when an attempt has been made to search for a reserved record.

10719 CENTREX SERVICE NUMBER

The subscriber is a Centrex service number.

10720 DATABASE LOG BUFFER SIZE ERROR

Database log buffer size is erroneous, or there is an unacceptable dis-agreement on the correct size. Automatic recovery is executed to resolve the correct size and to distribute it. However, if the error stays on or repeats itself, then the log buffer size should be checked and fixed manually to DBPARA files both on disks and in RAM-memory. Further, the computer units in question should be restarted.

10721 CENTREX GROUP NONEXISTENT

There is no Centrex group.

10722 SUBNUMBER OF CENTREX GROUP VACANT

The subnumber of the Centrex group is vacant.

10723 SUBNUMBER OF CENTREX GROUP RESERVED

Page 121: DX Error Messages

DN987378Issue 24-0

121

General Error Messages of System DX error messages

Id:0900d8058077e097

The subnumber is reserved for a member of a Centrex group.

10724 MEMBER OF CENTREX GROUP WITH SUBNUMBER

The member of a Centrex group has a subnumber.

10725 MEMBER OF CENTREX GROUP WITHOUT SUBNUMBER

The member of a Centrex group does not have a subnumber.

10726 ERROR IN SEIZING TIME SLOT FOR SUBSCRIBER

Seizing of time slot for a subscriber in a subscriber module did not succeed. All time slots for subscribers in the subscriber module are currenty reserved.

10727 OUTCALL IDENTIFIER CHANGE NOT POSSIBLE

When a Centrex operator serves several Centrexes, change of the outcall identifier of one single Centrex is not possible, because the Centrex-groups must have the same outcall identifier.

10728 ILLEGAL CHANNEL CONFIGURATION

An attempt was made to use unknown channel types, or channel types in a TRX are incompatible.

10729 FREQUENCY ALREADY USED IN CELL

The frequency is already in use in the cell. It is not allowed to create several transceivers using the same frequency (ARFCN) in the cell.

10730 INCALL IDENTIFIER CHANGE NOT POSSIBLE

When a Centrex operator serves several Centrexes, change of the incall identifier of single Centrex is not possible because the Centrex groups must have the same incall identifier.

10731 OUTCALL IDENTIFIER RESERVED

The value of the outcall identifer is reserved for a Centrex incall identi-fier, or for the first digits of subnumbers of a Centrex.

10732 INCALL IDENTIFIER RESERVED

The value of the incall identifer is already reserved for a Centrex outcall identifier, or for the first digits of subnumbers of a Centrex.

10733 FIRST DIGITS OF SUBNUMBER RESERVED

The value of the first digits of a subnumber is already reserved for an outcall identifier, incall identifier, or another Centrex group of the operator serving the Centrex in question.

10734 NAME OF THE EXCHANGE EXISTENT

The name of the exchange exists.

10735 NAME OF THE EXCHANGE NONEXISTENT

The name of the exchange does not exist.

10736 STATISTICS NOT STARTED

Statistics have not been started.

10737 CHANGE OF NUMBER LENGTH NOT POSSIBLE

A change of the number length is not possible.

10738 SENDING OF DATA FAILED

Page 122: DX Error Messages

122 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Sending of data failed due to missing data messages.

10739 TOO MANY BLOCKS RESERVED FOR ACCESS GRANT MESSAGES IN BTS

In the CCH configuration parameters of the BTS, too many blocks have been reserved for Access Grant messages. When a combined BCCH is used, the number of blocks for Access Grant has to be reduced.

10740 REFRESHING OF A SUB DATABASE HAS FAILED

In a sub database, refreshing from the host database has failed. Timeout may have occurred, or transactions from the host database or those toa sub database have failed.

10741 DATA ARE INCONSISTENT IN DATABASE SYSTEM

In the database system database inconsistency has been found, e.g. the two-directional implementation of a relation contains inconsistent data.

10742 ESCAPE CODE FAULTY

The given value differs from the stored value in the PNEFIL file.

10743 NEW PNDFIL VARIANT NEEDED

There is no longer room to add a new full-size private numbering index (PNI).

10744 PNDFIL REACHING MAXIMUM CAPACITY

The PNDFIL file variant where this private numbering index (PNI) is stored is getting full.

10745 PNDFIL FULL

It is not possible to create this analysis because the corresponding PNDFIL file variant is full.

10746 PNEFIL CORRUPTED

The contents of the PNEFIL file record are faulty.

10747 PNI ANALYSIS TREE CORRUPTED

The private numbering index analysis tree in the PNDFIL file is faulty.

10748 DIGIT ANALYSIS TREE CORRUPTED

The private number analysis tree or long number digit analysis tree in the PNDFIL file is faulty.

10749 PNRFIL CORRUPTED

The contents of the PNRFIL record are faulty.

10750 NONEXISTING PNI

There is no analysis for that private numbering index in the PNI analysis tree.

10751 UNFINISHED BCF BUILD HANDLING OPERATION EXISTS

There is an unfinished BCF build handling operation going on in the BSC, and no new operation can be started.

10752 WSS AND QNG NOT UPDATED

Data of WSS and QNG were not updated.

Page 123: DX Error Messages

DN987378Issue 24-0

123

General Error Messages of System DX error messages

Id:0900d8058077e097

10753 INVALID NUMBER OF ALTERNATIVE SUBDESTINATION

Number of the added alternative subdestination is invalid.

10754 POSITION NUMBER NOT RESERVED FOR OPERATOR SERVICE POSITION

The position number has not been reserved for an operator service position.

10755 ALL ALTERNATIVE SUBDESTINATIONS ALREADY CREATED

An attempt has been made to create an alternative subdestination althoug all alternatives have already been reserved.

10756 SAVE SET MARK READ

The tabe block read was a delimiter of file groups (save set mark).

10757 PHYSICAL CHANNEL CONNECTED TO ETHERNET DATA TERMINAL

The physical channel is connected to an Ethernet data terminal.

10758 ETHERNET DATA TERMINAL DOES NOT EXIST

The Ethernet data terminal is not found with the given parameters (search key) in the OETFIL file.

10759 ETHERNET DATA TERMINAL ALREADY EXISTS

The Ethernet data terminal already exists in the OETFIL file.

10760 UNLOCKED PHYSICAL CHANNEL CONNECTED TO ETHERNET DATA TERMINAL

An unlocked physical channel is connected to an Ethernet data terminal (physical channel is in UNLOCKED state).

10761 SOFTWARE PACKAGE DOWNLOAD TO BCF INTERRUPTED

BTDOWN has failed in transferring a file segment from the fixed disk of the BSC to the BTS.

10762 DEFAULT DOWNLOAD REQUEST SENT TO BCF

BTDOWN has failed in receiving build information from SWADMI or in reading from the fixed disk of the BSC, and has therefore sent a default download request to the BCF.

10763 NO MASTER FILE REQUEST RECEIVED FROM ABIPRB

BTDOWN has not received the master file request transmitted from BTS by ABIPRB.

10764 NO APPLICATION FILE REQUEST RECEIVED FROM ABIPRB

BTDOWN has not received an application file request transmitted from the BTS by ABIPRB.

10765 ACKNOWLEDGE MESSAGE FROM ABIPRB MISSING

BTDOWN has sent a file record to the BTS and has not received an acknowledge message transmitted from the BTS by ABIPRB.

10766 NACK -MESSAGE RECEIVED FROM ABIPRB

BTDOWN has sent a file record message and received NOT OK acknowledge message transmitted from the BTS by ABIPRB.

Page 124: DX Error Messages

124 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10767 DOWNLOAD OPERATION NOT ALLOWED

BTDOWN is busy or, in the case of background download operation, the BTS has no flash memory.

10768 NO FLASH MEMORY IN BTS

Downloading as a background operation is not allowed to the BTS without flash memory.

10769 DOWNLOAD PROGRAM BLOCK (BTDOWN) BUSY

BTDOWN can not create new hands.

10770 DISK COPY ALREADY STARTED

The FSKDIS program block sends a message to the FSSPRO program block informing the latter if disk copying has already been started when FSKDIS receives a start disk copying message.

10771 OPERATOR SERVICE HAS SERVICE NUMBER

Operator service has a service number.

10772 OPERATOR SERVICE HAS OPERATOR

Operator service has an operator.

10773 INCORRECT OUTCALL IDENTITY

Incorrect outcall identity.

10774 INCORRECT INCALL IDENTITY

Incorrect incall identity.

10775 INCORRECT FIRST DIGITS LENGTH

Incorrect length of the first digit.

10776 OPERATOR SERVICE ALREADY HAS SIMILAR FIRST DIGITS

Operator service already has similar first digits.

10777 HOPPING BTS HAS INCORRECT STATE FOR REQUESTED TASK

A Base Station with frequency hopping in use has an operational state which is not suitable with the requested task. Certain configuration changes in hopping cell are not allowed when the BTS is in working state.

10778 BCF SW BUILD IS NOT IDENTICAL ON BOTH DISKS OF BSC

The BCF software build contents are different on the disks of the BSC.

10779 BCF BUILD IS THE DEFAULT PACKAGE

When the user tries to detach the default BCF build, this message is printed.

10780 INCORRECT OPERATOR SERVICE TYPE

Incorrect operator service type.

10781 INCORRECT SUBSCRIBER CATEGORY

Incorrect subscriber category.

10782 REPORT BUFFER FILE NOT FOUND

Report buffer file (ring buffer) for the given buffer identification is not found.

Page 125: DX Error Messages

DN987378Issue 24-0

125

General Error Messages of System DX error messages

Id:0900d8058077e097

10783 CAN NOT CHANGE CALL TYPE

Can not change the call type.

10784 INCORRECT CALL TYPE

Incorrect call type.

10785 INCORRECT QUEUEING MODE

Incorrect queueing mode.

10786 THERE IS NO BCCH TRX UNDER CELL

The cell must have a transceiver (TRX) of the broadcast control channel (BCCH or CPBCH).

10787 NO SERVICE NUMBER IDENTITY

There was no such service number identity.

10788 LOG_IN FUNCTION IS NOT ALLOWED

LOG_IN function is not allowed.

10789 INCOMPATIBLE OPERATOR APPLICATION TYPE

Incompatible operator application type.

10790 RESERVED CALLING CARD SUBSCRIBER NUMBER

The subscriber number is a reserved calling card subscriber.

10791 RESERVED INDIRECT SUBSCRIBER NUMBER

The subscriber number is a reserved indirect subscriber number.

10792 VACANT CALLING CARD SUBSCRIBER NUMBER

The number is a vacant calling card subscriber number.

10793 VACANT INDIRECT SUBSCRIBER NUMBER

The number is a vacant indirect subscriber number.

10794 CALLING CARD SUBSCRIBER

A calling card subscriber.

10795 INDIRECT SUBSCRIBER

Indirect subscriber number.

10796 ILMT BUSY

The ILMT measurement device in SBCN/RSCN plug-in unit is busy.

10797 ILMT FAULTY

The ILMT measurement device in SBCN/RSCN plug-in unit is faulty.

10798 LOOPING TEST ERROR

Looping test error in the LIxxx plug-in unit.

10799 FDCBUF FILE SIZE TOO SHORT

The FSKDIS program block cannot create the records of all FR users and FR trunk accesses at a time.

10800 SUBSCRIBER HAS ALSO A PARALLEL NUMBER IN USE

The subscriber has another number in use, too; an old one that will be erased after a period of time, and a new one.

Page 126: DX Error Messages

126 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10801 SUBSCRIBER NUMBER RESERVED HAS ALSO A PARALLEL NUMBER IN USE

The subscriber number reserved has also another number as a parallel number.

10802 RSU SUBSCRIBER HAS PARALLEL NUMBER IN USE

An RSU subscriber has also a parallel number in use.

10803 CHANGED SUBSCRIBER NUMBER HAS ALSO PARALLEL ONE IN USE

A changed subscriber number has a parallel number as well.

10804 DPABX SUBSCRIBER NUMBER HAS ALSO PARALLEL NUMBER IN USE

A DPABX subscriber number has also a parallel number in use for a period.

10805 ARF SUBSCRIBER HAS ALSO A PARALLEL NUMBER IN USE

An ARF subscriber has also a parallel number in use.

10806 IDS SUBSCRIBER HAS A PARALLEL NUMBER IN USE

The identification subscriber (IDS) has a parallel number in use.

10807 CCS SUBSCRIBER HAS A PARALLEL NUMBER IN USE

The calling card subscriber (CCS) has a parallel number in use.

10808 PARALLEL SUBSCRIBER NUMBER RELEASED BUT STILL IN PARALLEL MODE

The parallel subscriber number has been released but is still under parallel modification.

10809 OSI ADDRESS IS ASSOCIATED TO PHYSICAL CHANNEL GROUP

The OSI address has been associated with a physical channel group.

10810 OSI CONNECTION REJECTED BY OSI STACK

Error coded returned by NMCOMM program block because of rejection of an OSI connection.

10811 INCORRECT FIRST DIGITS

The first digits of the subnumber are incorrect.

10812 FIRST DIGITS CHANGE NOT POSSIBLE

When a Centrex operator serves several Centrexes, change of the first digits of one single Centrex is not possible.

10813 VXCN COMMUNICATION FAILURE

Communication failure between the VXCN and the OMU, or the MUX, or between two program blocks in the VXCN.

10814 MOBILE ALLOCATION LIST OF FREQUENCY HOPPING SYSTEM IS FULL

Attempts have been made to add too many TRXs to the frequency hopping system.

10815 TOO FEW BLOCKS RESERVED FOR ACCESS GRANT MESSAGES IN BTS

Page 127: DX Error Messages

DN987378Issue 24-0

127

General Error Messages of System DX error messages

Id:0900d8058077e097

In the CCH configuration parameters of the BTS, too few blocks have been reserved for Access Grant messages. When a SDDCH/8 with CBCH is used, the number of Access Grant blocks has to be added.

10816 NO CBCH CHANNEL FOR SMSCB USAGE IN CELL

There is no radio channel for SMSCB usage in the channel configura-tion of the cell. A CBCH channel must be added to the cell to perform SMSCB.

10817 TEST RADIO CHANNEL CANNOT BE ALLOCATED

No radio channel in the TRX can be allocated for testing, because they are all busy or locked by the user.

10818 SNPA ADDRESS IS ALREADY IN OSI ACCESS CONTROL LIST (ACL)

The SNPA address is already in the OSI access control list (in the OALFIL file - OSI access list file).

10819 SNPA ADDRESS IS NOT IN OSI ACCESS CONTROL LIST (ACL)

The SNPA address is not in the OSI access control list (in the OALFIL file - OSI access list file).

10821 FILE CREATION NOT ALLOWED

The creation of a file is not allowed.

10822 EVENT DATA IN BUFFER FILE

Because of a faulty connection to the OMC, the data of a transmitted event notice ended up in a buffer file.

10823 EVENT BUFFER FILE IS FULL

The file used for buffering event notices is full, and old data is being overwritten by incoming new notices.

10824 BSS-SYSTEM HAS NO RESOURCES FOR REQUESTED TASK

The BSS-system is busy. It has not finished its previous task, concern-ing the object. The unfinished task can be an automatic recovery task or it can be the previous MMI task.

10825 NO SUCH DATABASE OCCURRENCE DEFINED IN DBPARA

There is no such database occurrence defined for the database in the DBPARA file.

10826 BCF SOFTWARE HANDLING CONFIRMATION REQUIRED

There are some BCF software management commands that need con-firmation before the SWADMI program block will execute the com-mands.

10827 MEASUREMENT ALREADY STARTED

The activation of the measurement has failed because it is already in progress.

10828 MEASUREMENT NOT STARTED

The measurement has not been activated.

10829 MEASUREMENT NOT CREATED

Page 128: DX Error Messages

128 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The operation to be performed on the measurement has failed because the measurement itself has not been created.

10830 COMMUNICATION ERROR BETWEEN FSISTA AND FSDSTA

There is a communication failure between the FSISTA and FSDSTA program blocks.

10831 DLCI NUMBER NOT FOUND

The DLCI number is not found.

10832 MFST CHANNEL CLOSED AFTER SENDING ALL BUFFERED CHARACTERS

The signalling channel of the MFST plug-in unit has been closed, all buffered characters having been sent.

10833 DLCI ALREADY RESERVED

DLCI is already reserved.

10834 INCORRECT OPERATOR IDENTITY

The SFDATA database has an incorrect index to the operator_data file.

10835 INCORRECT CENTREX SUBNUMBER

The number is not a subnumber of the CENTREX.

10836 ETHERNET DRIVER IS UNABLE TO SEND MAC FRAMES

The Ethernet driver is out of resources.

10837 ORDINARY SERVICE NUMBER

The subscriber is an ordinary service number.

10838 ERROR IN READING PARAMETER FILE

The reading of the parameter file (PRFILE) has failed.

10839 ERROR IN DIGITAL SIGNAL PROCESSING

An error has occurred in the processing of the digital measurement signal.

10840 CONFLICT BETWEEN INITIALISED AND REQUESTED PCM NUMBER IN MFST

The requested PCM number is different from the initialised PCM number in an MFST channel of an MFST plug-in unit.

10841 ATTEMPT TO CLOSE MFST CHANNEL OPENED BY OTHER USER

The identification data of the user that tried to close an MFST channel differ from those of the user that opened the channel in question.

10842 OPERATOR TYPE MODIFICATION NOT ALLOWED

Operator type modification is not allowed.

10843 ANALYSIS OF CHARGING CONTINUES

The analysis of charging continues with the analysis of the transmission medium requirement.

10844 TMR ANALYSIS OF CHARGING ALREADY EXISTS

The transmission medium requirement analysis of the charging analysis already exists.

Page 129: DX Error Messages

DN987378Issue 24-0

129

General Error Messages of System DX error messages

Id:0900d8058077e097

10845 TMR ANALYSIS OF CHARGING NONEXISTENT

There is no transmission medium requirement analysis of charging.

10846 NOT LAST CHARGING

There are still transmission medium requirement analyses of charging left.

10847 NO RESPONSE FROM SUB DATABASE HANDLING PROGRAM BLOCK

A subdatabase handling program block does not answer. Check the existence and working state of the computer unit of the subdatabase.

10848 SUBSCRIBER HAS ALREADY MAXIMUM NUMBER OF MEMBER-SHIPS

The subscriber to be added into the hunting group is already a member in the maximum number (8) of hunting groups.

10849 UNLOCKED PHYSICAL CHANNEL IS ASSOCIATED TO ISO IP PARAMETER SET

The ISO IP parameter set is associated to the physical channel which is in the UNLOCKED state.

10850 PHYSICAL CHANNEL IS ASSOCIATED TO ISO IP PARAMETER SET

The physical channel is associated to the ISO IP parameter set.

10851 ISO IP PARAMETER SET DOES NOT EXIST

The given ISO IP parameter set is not found in the OIPARA file.

10852 ISO IP PARAMETER SET ALREADY EXISTS

The ISO IP parameter set already exists.

10853 PDU TIMERS ARE NOT COMPATIBLE

PDU timers (parameters max_pdu_lifetime and ra_timer fields in OIPARA file) are not compatible. See /ISO IP Configuration Parameter Handling, Command Manual, 2.6/, parameters network_span and RA_timer.

10854 CHANNEL STATE ALREADY EXISTS

The channel state is not changed, because it already exists.

10855 ALARM UNIT ADDRESS ALREADY EXISTS

An equipment with the given address already exists in the service channel. All equipments in the same channel have to have an address of their own.

10856 ALARM UNIT WITH GIVEN TYPE AND INDEX ALREADY EXISTS

An equipment with the given alarm unit type and index already exists. All equipments of the same type have to have a unique index under the same BSC.

10857 CHANNEL DOES NOT EXIST

A service channel with the given channel number does not exist.

10858 CHANNEL STATE IS ACTIVE

Page 130: DX Error Messages

130 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The service channel is active. Service channel activation has to be denied before operation.

10859 CHANNEL CONTAINS EQUIPMENT

The service channel contains equipment. The equipment has to be removed before operation.

10860 EQUIPMENT DOES NOT EXIST

Equipment with the given alarm unit type and index does not exist.

10861 MAXIMUM NUMBER OF CHANNELS EXCEEDED

The maximum number of service channels has been exceeded.

10862 MAXIMUM NUMBER OF EQUIPMENT EXCEEDED

The maximum number of equipment in the same service channel has been exceeded.

10863 PCM-TSL ALREADY USED AS SERVICE CHANNEL

The given PCM-TSL is already used as a service channel.

10864 DATABASE IS INCONSISTENT ON ONE OR MORE DISKS

This error code is used in situations where a database copy on a disk is found to be inconsistent.

10865 MEMBER TYPE IS INCORRECT

A hunting group can have three kinds of members: an ordinary member, a member of the hunting group, and a member external to the exchange. The member type is given in connection with the MML command. The error situation occurs if e.g. an attempt is made to add an ordinary member as a member of the hunting group.

10866 EXTENSION GROUP HAS ALREADY MAXIMUM COUNT OF MEMBERS

The count of members in a hunting group is limited. If this limit is exceeded, this error code is given.

10867 SUBSCRIBERS WITH DIFFERENT AREA CODE

The subscribers to be added in the same hunting group must have the same area code. If this is not the case, this error code is given.

10868 PVC INFORMATION IS NOT ALLOWED FOR A PHYSICAL CHANNEL THRU ETHERNET TERMINAL

The user tries to attach X.25 PVC information to a channel which provides ISO IP CNLS service.

10869 OOAFIL FILE READING FAILED

An attemp to read a single OOAFIL record failed.

10870 CONFLICT BETWEEN OAPFIL AND OOAFIL FILES

The OAPFIL and OOAFIL files contain contradictory information.

10871 CONFLICT BETWEEN ACTIVE AND PASSIVE UNIT OOAFIL FILE

The OOAFIL files of the active and passive units contain contradictory information.

10872 APPLICATION PARAMETERS ALREADY EXIST

Page 131: DX Error Messages

DN987378Issue 24-0

131

General Error Messages of System DX error messages

Id:0900d8058077e097

The application parameters already exist.

10873 ASWI UNIT IS NOT RESPONDING

The ATM Switching Unit is not currently responding.

10874 RESERVED FOR TESTING

The ATM virtual path/channel is currently involved in a switch test.

10875 UNABLE TO CONNECT INCOMING VIRTUAL CHANNEL

Attempt to connect to the incoming virtual channel failed.

10876 UNABLE TO CONNECT OUTGOING VIRTUAL CHANNEL

The attempt to connect the outgoing virtual channel failed.

10877 UNABLE TO RELEASE INCOMING VIRTUAL CHANNEL

The attempt to release the incoming virtual channel of a connection failed.

10878 UNABLE TO RELEASE OUTGOING VIRTUAL CHANNEL

The attempt to release the outgoing virtual channel of a connection failed.

10879 ASWI UNIT IS LOCKED

The ATM Switching Unit is currently locked.

10880 ERRORS DETECTED ON CONNECTION

An ATM virtual connection is currently subject to error.

10881 ATM LINE DOES NOT EXIST

The ATM Line does not currently exist.

10882 ATM IN-LINE UNAVAILABLE

The incoming ATM line is currently unavailable.

10883 ATM OUT-LINE UNAVAILABLE

The outgoing ATM line is currently unavailable.

10884 VIRTUAL PATH DOES NOT EXIST

The virtual path does not exist.

10885 VIRTUAL CHANNEL DOES NOT EXIST

The virtual channel does not exist.

10886 INCOMING VPI UNAVAILABLE

The incoming VPI is currently unavailable.

10887 INCOMING VCI UNAVAILABLE

The incoming VCI is currently unavailable.

10888 OUTGOING VPI UNAVAILABLE

The outgoing VPI is currently unavailable.

10889 OUTGOING VCI UNAVAILABLE

The outgoing VCI is currently unavailable.

10890 NO FREE VIRTUAL PATH

No free virtual path.

Page 132: DX Error Messages

132 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10891 NO FREE VIRTUAL CHANNEL

No free virtual channel.

10892 NO FREE INCOMING VIRTUAL CHANNEL

No free incoming virtual channel.

10893 NO FREE OUTGOING VIRTUAL CHANNEL

No free outgoing virtual channel.

10894 REQUESTED ATM LINE NOT FREE

The requested ATM line is not free.

10895 REQUESTED VPI NOT FREE

The requested virtual path is not free.

10896 REQUESTED VCI NOT FREE

The requested virtual channel is not free.

10897 VIRTUAL PATH CONNECTION DOES NOT EXIST

The virtual path connection does not exist.

10898 VIRTUAL CHANNEL CONNECTION DOES NOT EXIST

The virtual channel connection does not exist.

10899 PARAMETERS ATTACHED TO APPLICATION TO BE DELETED

The parameter block has been connected to an application to be deleted.

10900 FACILITY ALREADY IN THIS STATE

The facility is already in this state.

10901 CREATION OF ATM LINE FAILED

The error code originates from the ATM Switching database upon failure to create a new ATM line.

10902 VPI RESERVATION FAILED

The error code originates from the ATM Switching database upon failure to create a new virtual path.

10903 VCI RESERVATION FAILED

The error code originates from the ATM Switching database upon failure to create a new virtual channel.

10904 VIRTUAL PATH EXIST FOR LINE

The error code originates from the ATM Switching database when an attempt is made to release an ATM line with active virtual paths.

10905 VIRTUAL PATH CONNECTION EXISTS FOR VPI

The error code originates from the ATM Switching database when an attempt is made to release a virtual path used in an active connection.

10906 VIRTUAL CHANNEL EXISTS FOR VPI

The error code originates from the ATM Switching database when an attempt is made to release a virtual path which has an active virtual channel.

10907 VIRTUAL CHANNEL CONNECTION EXISTS FOR VCI

Page 133: DX Error Messages

DN987378Issue 24-0

133

General Error Messages of System DX error messages

Id:0900d8058077e097

The error code originates from the ATM Switching database when an attempt is made to release a virtual channel which is used in an active connection.

10908 ATM LINE BLOCKED

The error code originates from the ATM Switching database when an attempt is made to carry out a disallowed transaction on an ATM line.

10909 VPI BLOCKED

The error code originates from the ATM Switching database when an attempt is made to carry out a disallowed transaction on a blocked VPI.

10910 VCI BLOCKED

The error code originates from the ATM Switching database when an attempt is made to carry out a disallowed transaction on a blocked VCI.

10911 ERROR IN SERVICE REQUEST

The error code originates from the ATM Switching service upon detec-tion of an invalid parameter in a service request.

10912 CONGESTION IN ATM SWITCHING

The error code originates from the ATM Switching service when there is congestion.

10913 NO RESPONSE FROM ASWMAN

Error code generated upon timeout of ASWMAN.

10914 FUNCTIONAL UNIT NOT LOCALLY SUPPORTED

The CMISE protocol functional units are not locally supported.

10915 FUNCTIONAL UNIT NOT REMOTELY SUPPORTED

The CMISE protocol functional units are not remotely supported.

10916 PROTOCOL VERSION NOT LOCALLY SUPPORTED

The CMISE protocol version is not locally supported.

10917 CMISE PROTOCOL VERSION NOR REMOTELY SUPPORTED

The CMISE protocol version is not remotely supported.

10918 TERMINAL FUNCTION DOES NOT EXIST

The terminal function does not exist, or it has not been taken into use.

10919 COMMUNICATION FAILURE BETWEEN AS7 AND PROGRAM BLOCK

Communication failure between AS7 (PRLPGM) and a program block.

10920 HUNTING GROUP IS A MEMBER OF ANOTHER HUNTING GROUP

A hunting group can not be deleted if it is a member in another hunting group.

10921 BTS BUSY

The BTS is busy. Try again later.

10922 INVALID MESSAGE

An invalid message.

10923 ERROR IN THE VALUE OF PARAMETERS

Page 134: DX Error Messages

134 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An error in the value of the parameters or data.

10924 MESSAGE OUT OF STATE

Message out of state.

10925 EXECUTION PROBLEM

Problems have been encountered in the execution of the command.

10926 INVALID PARAMETER VALUE

Invalid parameter value.

10927 UNKNOWN OBJECT

Unknown object.

10928 OBJECT NOT ALLOWED

The object cannot be the target of a command/message.

10929 INVALID OBJECT STATE

The object state is not compatible with the transaction.

10930 UNIT IS NOT YET OPERATIONAL

The unit is not yet operational.

10931 SEQUENCE ERROR

A sequence error has occurred when transmitting a segmented message.

10932 BTS IS NOT EQUIPPED WITH A FLASH MEMORY

The BTS is not equipped with a FLASH memory.

10933 BTS DOES NOT CONTAIN THE SPECIFIED DIVERSITY

THE BTS does not contain the specified diversity.

10934 BTS CANNOT BE INITIALIZED DUE TO LACK OF CLOCKS

The BTS cannot be initialized because of lack of clocks.

10935 UNKNOWN UNIT IN CONFIGURATION MESSAGE

At least one unit is unknown in the configuration data message.

10936 CONFIGURATION DATA UNIT CANNOT BE CONFIGURED

At least one unit in the configuration message cannot be configured.

10937 ONE OR MORE ELEMENTARY TESTS WERE NOT PERFORMED

One or more elementary tests were not performed in the TRX test.

10938 LACK OF RESOURCES

Lack of resources.

10939 HARDWARE FAILURE

Hardware failure.

10940 SOFTWARE PROBLEM

Software problem.

10941 RESERVATION OF VIRTUAL PATH CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to reserve a virtual path connection.

Page 135: DX Error Messages

DN987378Issue 24-0

135

General Error Messages of System DX error messages

Id:0900d8058077e097

10942 RESERVATION OF VIRTUAL CHANNEL CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to reserve a virtual channel connection.

10943 CONNECTION OF VIRTUAL CHANNEL CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to set a virtual channel connection to the active state.

10944 CONNECTION OF VIRTUAL PATH CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to set a virtual path connection to the active state.

10945 DISCONNECTION OF VIRTUAL PATH CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to change the state of an active virtual path connection.

10946 DISCONNECTION OF VIRTUAL CHANNEL CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to change the state of an active virtual channel connection.

10947 RELEASE OF VIRTUAL CHANNEL CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to release a reserved virtual channel connection.

10948 RELEASE OF VIRTUAL PATH CONNECTION FAILED

This error code is generated when the ATM Switching Database is unable to release a reserved virtual path connection.

10949 WIRED ALARMS TEST IS NOT ALLOWED IN SPARE UNIT

There was an attempt to start the wired alarms test in a spare unit.

10950 INDIVIDUAL HUNTING NUMBER ALREADY EXISTS

A member of a hunting group can have individual hunting in one group at a time, if there is an attempt to set the facility in question in another group, this error code is generated.

10951 STATISTICS ALREADY STARTED

The statistics function has already been started.

10952 QUEUEING FOR RESOURCES HAS BEEN STARTED

Queueing for resources has been started. They are needed in a priority call.

10953 SUBSCRIBER IS NOT A MEMBER OF HUNTING GROUP

This error code is generated when a subscriber is set facilities that are available only to members of a hunting group, or when inquiring about a group.

10954 SUBSCRIBER HAS NO INDIVIDUAL HUNTING

Call control inquires about a member of a hunting group for whom indivual hunting supposedly has been set, or an MML command has been entered to delete individual hunting from a member of a hunting group.

10955 FRCMAN REJECTED SEMIPERMANENT FILE UPDATING

Page 136: DX Error Messages

136 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The updating of a semipermanent Frame Relay file has been rejected by FRCMAN.

10956 SEMIPERMANENT FILE UPDATING REJECTED BY FRDMAN

The updating of a semipermanent Frame Relay file has been rejected by FRDMAN.

10957 DIGITS NOT STORED FOR NUMBER REPETITION

Digits have not been stored for number repetition.

10958 MCMD CHARGING TAPE AT THE BEGINNING OF TAPE FILE

There was an attempt to write, onto an MCMD-format tape file, charging data without the file header block, although the tape was at the begin-ning of the file.

10959 MCMD-FORMAT CHARGING TAPE IS NOT AT THE BEGINNING OF TAPE FILE

There was an attempt to write charging data, containing file header info, to an MCMD-format charging tape, although the tape is not at the begin-ning of the file.

10960 INCORRECT MODULE NAME IN MODULE HEADER

There is an incorrect module name in the header of a load module.

10961 BTLARM HAS NOT ANSWERED BCF RESET OR BTS CONFIGURA-TION REQUEST

The BSC Configuration Updating Program Block (GUPDAT) has requested the BTS Alarm Handling and Recovery Program Block (BTLARM) to reset BCF or to configurate BTS. No answer was received in time.

10962 PXADMI HAS NOT ANSWERED D-CHANNEL STATE INQUIRY

The BSC Configuration Updating Program Block (GUPDAT) has inquired about the D-channel state from the PXADMI program block. No answer was received in time.

10963 ABIPRB OR BTS SITE HAS NOT ANSWERED TRX RESET OR STATE CHANGE REQUEST

The BSC Configuration Updating Program Block (GUPDAT) has requested the A-bis Interface Program Block (ABIPRB) to reset TRX, or to change the TRX administrative state on the BTS site via the BTS O&M link. No answer received in time.

10964 MFC CHARACTER BUFFER FULL IN MFST PLUG-IN UNIT

The MF signalling control program block has found that there was an attempt to write MFC characters into a full MFC character buffer.

10965 OFFSET OUT OF MODULE

An offset points outside of a module.

10966 INVALID RECORD SIZE

A files record size is invalid.

10967 INVALID MODULE IDENTIFICATION STRING

The identification string of a load module is invalid.

Page 137: DX Error Messages

DN987378Issue 24-0

137

General Error Messages of System DX error messages

Id:0900d8058077e097

10968 MAFILE CORRESPONDING TO ENVIRONMENT NOT FOUND

The MAFILE file corresponding to the environment of the SW package is not found.

10969 MAFILE CORRESPONDING TO DELIVERY NOT FOUND

The MAFILE file corresponding to the SW delivery is not found.

10970 MODULE CORRESPONDING TO MAFILE RECORD NOT FOUND

The module corresponding to a record in the MAFILE file is not found.

10971 MODULE NOT SYSTEM RELEASE DEPENDENT

A load module is not dependent on the system release level.

10972 MODULE HAS INCORRECT VERSION

The version of a load module is incorrect.

10973 MODULE HAS INCORRECT ENVIRONMENT ID

The environment ID of a load module is incorrect.

10974 MODULE HAS INCORRECT DELIVERY NAME

The delivery name of a load module is incorrect.

10975 MODULE HAS INCORRECT DELIVERY VERSION

The delivery version of a load module is incorrect.

10976 SUBDATABASE UPDATE FAILED

Subdatabase transaction failed. The error code was written into the logfile of the callers computer unit.

10977 LINE INTERFACE SOFTWARE VERSION UNSUITABLE FOR TEST

The version of the subscriber interface software is not suitable for the requested test.

10978 INCORRECT TEST STATE FOR THE OPERATION

The operation cannot be performed, as the state of the test is wrong.

10979 TRUNK RESERVATION THRESHOLD TABLE OBJECT NOT FOUND FROM RADIO NETWORK DATABASE

The Trunk Reservation decision threshold table has not been created into the radio network database.

10980 TRUNK RESERVATION THRESHOLD TABLE IS IN USE

The Trunk Reservation decision threshold table is used by a BTS. It cannot be deleted before the BTS using it is detached.

10981 DATABASE SYSTEM CONTAINS A FILE WITH ZERO LENGTH

There is a file with zero length in the database system.

10982 WRITING TO LOG FILE WHILE READING

The FR User Event Log File (FUELOG) is being written into at the time of reading.

10983 LOG EVENTS NOT FOUND

Log events are not found in the FR User Event Log File (FUELOG).

10985 TEST INTERRUPTED

Execution of the tests has been interrupted.

Page 138: DX Error Messages

138 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

10986 TMRANA RECORD NONEXISTENT

The Transmission Medium Requirement Analysis file (TMRANA) record does not exist.

10987 ET UNIT WITH D-CHANNEL DID NOT ANSWER

An exchange terminal unit with a D-channel has failed to respond within time supervision.

10988 AON CHARACTER NOT RECEIVED

No AON character has been received after the MFST channel was opened.

10989 AON RECEIVING ERROR

The error was in AON receiving.

10990 MODULE UPDATE FAILED

The updating of the information in the subscriber module failed.

10991 THE FILE IS SYSTEM RELEASE DEPENDENT AND CANNOT BE CREATED IN THE EXCHANGE

The file cannot be created in the exchange, it is part of the software delivery.

10992 FR USER ACCESS IS USED BY VIRTUAL CONNECTION

A Frame Relay user access is used by a virtual connection.

10993 FR TRUNK ACCESS IS USED BY VIRTUAL CONNECTION

A Frame Relay trunk access is used by a virtual connection.

10994 FR TRUNK ACCESS NOT PASSIVATED

A Frame Relay trunk access has not been passivated.

10995 FR VIRTUAL CONNECTION NOT PASSIVATED

A Frame Relay virtual connection has not been passivated.

10996 PROGRAM BLOCK COMMUNICATION FAILURE

There is a communication failure between program blocks. The program blocks concerned are specified in the PROGRAM BLOCK COMMUNICATION ERROR alarm that is set simultaneously.

10997 OMOLIB SEARCH FAILED

The requested object was not found by the Q3 Object Model Library (OMOLIB).

10998 OMOLIB OBJECT DOES NOT EXIST

The requested object does not exist.

10999 OMOLIB FINDS NO VALUE FOR OBJECT

No value found for the requested object by the Q3 Object Model Library (OMOLIB).

11000 OMOLIB ROUTINE NOT DEFINED FOR OBJECT

No library routine was defined for the requested object.

11001 ILLEGAL HANDLE TO INTERNAL POSITION NUMBER ARGUMENT TABLE

Page 139: DX Error Messages

DN987378Issue 24-0

139

General Error Messages of System DX error messages

Id:0900d8058077e097

An MML program tries to read a non-existent internal position number argument table.

11002 BCCH ALLOCATION FREQUENCY LIST WAS NOT FOUND FROM THE DATABASE

The BCCH allocation frequency list has not been created into the radio network database.

11003 BCCH ALLOCATION FREQUENCY LIST IS STILL USED BY SOME BTS

The BCCH allocation frequency list cannot be deleted, if a BTS is still using it.

11004 BCCH ALLOCATION FREQUENCY LIST IS FULL

No more frequencies can be added to the BCCH allocation frequency list.

11005 BTS IS NOT EQUIPPED WITH STM

A BTS is not equipped with a STM.

11006 COMMUNICATION FAILURE BETWEEN BTS OMU AND STM

A communication failure has occurred between a BTS OMU and a STM.

11007 STM CARRIER SETTING FAILED

The setting of a STM carrier wave has failed.

11008 STM BCCH SYNCHRONISATION FAILED

The synchronisation of a STM to a given BCCH channel has failed.

11009 INVALID BCCH FREQUENCY WAS GIVEN BY BSC TO BTS

An invalid BCCH frequency was given by the BSC to a BTS.

11010 UNSPECIFIED ERROR DURING STM OPERATION

An unspecified error has occured during a STM-related operation.

11011 NO CALL REPORT IS AVAILABLE FROM STM

There is no call report available from the STM.

11012 TEST INTERRUPTED BY USER

The user has interrupted a test.

11013 UNKNOWN LOGICAL ADDRESS OF TRANSMISSION EQUIPMENT SENT BY BSC

The logical address of an unknown transmission equipment was sent by the BSC.

11014 COMMUNICATION FAILURE BETWEEN BTS OMU AND TRANSMIS-SION EQUIPMENT

There was a communication failure between the BTS OMU and the transmission equipment.

11015 INVALID TEST PARAMETERS

Invalid test parameters.

11016 METERS INQUIRY BUSY

The interrogation of the meters is in progress.

Page 140: DX Error Messages

140 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11017 UNSPECIFIED ERROR OCCURED DURING SCHEDULED TESTING

An unspecified error occured during scheduled testing in the BSC.

11018 UNSPECIFIED ERROR OCCURED DURING TEST

An unspecified error occured during a test.

11019 NO TEST GOING ON IN CONCERNED BCF

There is no test going on in the BCF in question.

11020 TMGMAN IS BUSY WITH ANOTHER TREHAN MML SESSION

The starting of a TREHAN MML session was rejected because TMGMAN is already engaged in another session.

11021 MUX SIGNALLING INCOMPATIBLE FOR MEASUREMENT

The MUX signalling does not recognise subscriber measurements.

11022 PCM-TSL RESERVED

The PCM-TSL is already reserved.

11023 POSITION ID NOT FOUND

The position ID does not exist.

11024 INVALID FILTER VALUE IN CMISE PRIMITIVE

The OCEAPI library returns this error code if the filter value given by the user of the library is invalid.

11025 INVALID SCOPE VALUE IN CMISE PRIMITIVE

The OCEAPI library returns this error code if the scope value given by the user of the library is invalid.

11026 GROUP LOGGING NOT ACTIVATED

Group logging has not been activated by the MML program.

11027 NOT DAS POSITION

The position is not a DAS position.

11028 DAS ID RESERVED

The DAS identity is reserved.

11029 INCORRECT CALL RETURN NUMBER

Incorrect call return number.

11030 INTERNAL SERVICE NUMBER

Internal service number.

11031 NOT DA SERVICE NUMBER

Not a DA (IBM/DAS) service number.

11032 BCF BUILD EXISTS ON BSC DISK

BCF build already exists in the BCF build handling system of the BSC and in the fixed disk of the BSC.

11033 EMPTY BCF BUILD SUBDIRECTORY NOT FOUND

Empty BCF build directory is not found on the fixed disk of the BSC.

11034 SUBDATABASE AND MODULE UPDATES BOTH FAILED

Page 141: DX Error Messages

DN987378Issue 24-0

141

General Error Messages of System DX error messages

Id:0900d8058077e097

The changes could not be updated into the subdatabase. Also the updating of subscriber module information failed.

11035 NO WAKE-UP ORDERS

There are no active wake-up orders.

11036 NO SUCCESSFUL WAKE-UP CALLS

No successful wake-up calls were found.

11037 INCORRECT ROUTINE TEST PARAMETER

A routine test parameter is found to be incorrect.

11038 DISK UPDATE OF RTPARA IN PROGRESS

It is not possible to modify the routine test parameters in the RTPARA file as the previous modification has not yet been updated to disk.

11039 INCORRECT ROUTINE TEST TYPE

The given routine test type is incorrect.

11040 INVALID JUMPER GROUP

The jumper group given in the jumper group parameter has not been defined in the JVALUE file.

11041 FAILURE TO GENERATE ROUTINE TEST REPORT

Generating a routine test report has failed because of a failure in the routine test software.

11042 OUTPUT OF ROUTINE TEST REPORT FAILED

The outputting of the routine test report has failed completely.

11043 OUTPUT OF ROUTINE TEST REPORT FAILED PARTIALLY

The outputting of the routine test report has failed on some of the pre-defined devices.

11044 CONFLICT BETWEEN PARAMETERS OF OWN CELL AND ADJACENT CELL

When creating or modifying an adjacent cell, the parameters are in conflict with the parameters of own cell.

11045 LDIG INVALID

LDIG Analysis invalid (LDIG = long digit).

11046 SDIG INVALID

The given SDIG (short digit) is invalid.

11047 SDIG AND LDIG INVALID

Both the given SDIG (short digit) and the given LDIG (long digit) are invalid.

11048 ERRONEOUS COUNTRY CODE

The country code given does not match with the one in the HRNFIL file.

11049 RANGE GIVEN OVERFLOWS HRNFIL MAXIMUM

Range given causes the total numbers of a given type of range to exceed the maximum.

11050 RANGE GIVEN OVERLAPS WITH ANOTHER

Page 142: DX Error Messages

142 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Range given overlaps with a range previously defined.

11051 ERROR READING PRFILE

Error reading PRIFLE.

11052 NO TEST EQUIPMENT DEFINED FOR BCF IN QUESTION

There is no test equipment defined in the database of the BSC for the BCF for the test to be started.

11053 INVALID TEST EQUIPMENT DEFINED FOR TEST IN QUESTION

The test equipment defined for the BCF and for the test in question is invalid.

11054 PLUG-IN UNIT TYPE OF JUMPER DOES NOT MATCH INTERFACE TYPE

The plug-in unit type in the jumper group record (file JVALUE) does not correspond to the plug-in unit type of the subscriber line interface.

11055 ERROR IN SETTING PROTECTION

This error code is sent when setting the 2 Mbit/s protection failed.

11056 ETHERNET TERMINAL NOT FOUND FROM OETFIL

An Ethernet terminal device, found in OPCFIL, is not found in OETFIL.

11057 TIME IS UNDEFINED

The last freezing and the last disk copying are not carried out, or the next disk copying has not been defined.

11058 DISTRIBUTED PART COUNTERS FREEZING IN PROGRESS

The freezing of the counters of the distributed part is in progress.

11059 DATA COLLECTION AFTER FRU CHANGE IS IN PROGRESS

Data collection from the changed FRU unit is in progress.

11060 DISK COPYING IS IN STOPPED STATE

Disk copying is in the STOPPED state.

11061 NO SUCH TP INSTANCE

The given termination point does not exist.

11062 NO SUCH GTP INSTANCE

The given group termination point does not exist.

11063 NO SUCH TPPOOL INSTANCE

The given termination point pool does not exist.

11064 NO TP IN TPPOOL

There is no free termination point in the termination point pool.

11065 PART OF GTP

The given termination point is part of a group termination point.

11066 MEMBER OF TPPOOL

The given termination point is part of a termination point pool.

11067 INCORRECT TP

The given termination point is not correct.

Page 143: DX Error Messages

DN987378Issue 24-0

143

General Error Messages of System DX error messages

Id:0900d8058077e097

11068 INCORRECT GTP

The given group termination point is not correct.

11069 CIC RESERVED

The PCM circuit has already been defined for another destination point.

11070 CIC ALREADY IN USE

The CIC is already in use.

11071 TASK SENT TO PASSIVE UNIT

A task request was sent to the passive unit. This error is possible in a unit switchover. Try to send the task request again after a while.

11072 STATUS CHANGED TO DEFAULT BUILD, BUT ACTIVATION FAILED

The default build in BCF has been changed, but downloading to BCF was unsuccessful.

11073 NO RESPONSE FROM RSAI

A program block on the RSAI unit has failed to acknowledge a message within the time supervision period.

11074 START AND END TIMES OF ROUTINE TESTING ARE TOO CLOSE

The starting and finishing times of routine testing are defined too near each other. The daily (busy or idle) time for routine testing is too short. The difference between the starting and finishing time must be at least one hour.

11075 FR NODE DOES NOT EXIST

The Frame Relay node does not exist.

11076 FR NODE ALREADY EXISTS

The Frame Relay node already exists.

11077 GIVEN TEST OBJECT DOES NOT EXIST

The given test object does not exist in the exchange configuration.

11078 DIFFERENCE BETWEEN TRANSACTION CHECKSUMS IN WO AND SP

The check sums of the updates of a database transaction differ in WO from those in SP.

11079 WIRED ALARM TEST BUSY

The wired alarm test is busy. Try again after a little while.

11080 PROCESS NOT IN NORMAL WORKING STATE

A process is not in a normal working state. The working state of the unit is such that the process is unable to function in it (or the process has remained in a wrong state).

11081 FLASH MEMORY IS FULL

Old data is updated and new data is inserted, but FLAMAN is no longer able to handle the FLASH memory correctly. Eventually, FLAMAN will reject all updating and inserting requests, as the FLASH memory runs out of space. This error code is a warning and means that FLAMAN can

Page 144: DX Error Messages

144 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

still serve for a while, but soon FLAMAN will no longer be able to write into the FLASH memory.

11082 OPERATION PREVENTED IN SPLIT UNIT

A function has been prevented from being carried out in a split unit.

11083 OPERATION PREVENTED IN TRIAL CONFIGURATION

A function has been prevented from being carried out in the trial config-uration.

11084 BSIC VALUE OF ADJACENT CELL DIFFERS FROM CORRESPOND-ING OWN CELL VALUE

This error code is produced when an adjacent cell is created or modified whose given BSIC differs from the BSIC of the own cell.

11085 PARAMETER MS_TXPWR_MAX_CELL OF ADJACENT CELL DIFFERS FROM CORRESPONDING OWN CELL VALUE

The ms_txpwr_max_cell parameter value given to an adjacent cell to be created or modified differs from that of the own cell.

11086 CELL_TYPE PARAMETER VALUE OF ADJACENT CELL DIFFERS FROM CORRESPONDING OWN CELL VALUE

The value of the cell_type parameter of an adjacent cell to be created or modified is different from that parameter value in the own cell.

11087 VALUE OF PARAMETER BCCH_FREQ OF ADJACENT CELL DIFFERS FROM CORRESPONDING OWN CELL

When creating or modifying an adjacent cell, the given bcch_frequency value differs from that of the own cell.

11088 ALARM NOT FOUND IN BTRFIL

An alarm number is not found in BTRFIL.

11089 BLOCKED ALARMS NOT FOUND IN BTRFIL

Alarm numbers in blocked state are not found in the BTRFIL file.

11090 ALARM NOT FOUND IN ALARM HISTORY

An alarm is not found in the alarm history.

11091 ALARM NOT FOUND IN RING BUFFER FILE

An alarm is not found in the ring buffer file.

11092 WAITING FOR 500 HZ SIGNAL STOPPED BECAUSE OF TIME OUT

The 500 Hz input signal was not found during the time supervision period.

11093 WAITING FOR 425 HZ SIGNAL STOPPED BECAUSE OF TIME OUT

The 425 Hz input signal was not found during the time supervision period.

11094 SERVICE PROFILE IS ALREADY ATTACHED TO OSI APPLICATION

The service profile has already been attached to the OSI application.

11095 SERVICE PROFILE ATTACHED TO APPLICATION TO BE DELETED

A service profile is attached to the application that is to be deleted.

11096 NO SERVICE PROFILE ATTACHED TO OSI APPLICATION

Page 145: DX Error Messages

DN987378Issue 24-0

145

General Error Messages of System DX error messages

Id:0900d8058077e097

No service profile has been attached to the given OSI application. The service profile has to be found in the OOAFIL file.

11097 UNDER A BCF ALL HSN:S OF BTS:S MUST BE 0 OR OTHER THAN 0

Hopping can be defined to be cyclic (HSN=0) or random (HSN other than 0). Cyclic and random hopping cannot be defined simultaneously under a BCF.

11098 PXNETM HAS NOT ANSWERED D-CHANNEL STATE INQUIRY

GUPDAT has inquired about the state of the D-channel from the PXNETM program block. No answer was received in time.

11099 NO ANSWER RECEIVED FOR TEST STOPPING REQUEST

IS1MAS has requested, unsuccessfully, ISHDRV to stop the ISDN line test.

11100 D-CHANNEL IS BLOCKED

The D-channel is blocked because of a fault by the system or the user.

11101 ISDN SUBSCRIBER LINE ACTIVATION FAILURE

The activation failed because the line or the interface is faulty.

11102 NO ANSWER RECEIVED TO TEST LOOP CONNECTION REQUEST

The ISDN subscriber line is not looped because the line or the interface is faulty.

11103 CALL DISCONNECTION FAILED

The disconnection of a call failed because the calls priority was higher than the tests.

11104 D-CHANNEL TEST HAS FOUND DATA ERROR

Bit errors were found from the D-channel, the D-channel is faulty.

11105 TEST ABORTED BECAUSE OF PREVIOUS DEACTIVATION

A test has been aborted before the time limit exceeded and the test result is incorrect. The previous deactivation may have been e.g. an incoming call.

11106 READING OF BIT ERROR COUNTERS FAILED

The reading of the bit error counters was unsuccessful because the transmission circuit did not answer.

11107 COMMUNICATION FAILURE BETWEEN MODULE CONTROLLER AND LINE INTERFACE PLUG-IN UNIT

Communication has failed between a module controller (SBCN/RSCN/etc.) and a line interface plug-in unit (LID5 etc.) because the time limit was exceeded, or the transmitting program did not answer.

11108 B-CHANNEL TEST HAS FOUND DATA ERROR

Bit errors were found in the B-channel, the B-channel is faulty.

11109 SCSI ADDRESS ALREADY EXISTS

There has been an attempt to add an SCSI device to an already reserved bus address.

11110 AD&C SUBSCRIBER

Page 146: DX Error Messages

146 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The subscriber type is AD&C.

11111 REMINDER CALL SUBSCRIBER WITH CHARGING

A reminder call subscriber who has charging.

11112 REMINDER CALL SUBSCRIBER WITH NO CHARGING

A reminder call subscriber who has no charging.

11113 AD&C SUBSCRIBER NUMBER IS VACANT

AD&C subscriber number is vacant.

11114 AD&C SUBSCRIBER NUMBER RESERVED

AD&C subscriber number is reserved.

11115 REMINDER CALL SUBSCRIBER NUMBER WITH CHARGING IS VACANT

A reminder call subscriber number which has charging is vacant.

11116 REMINDER CALL SUBSCRIBER WITH CHARGING IS RESERVED

A reminder call subscriber who has charging is reserved.

11117 REMINDER CALL SUBSCRIBER WITH NO CHARGING IS VACANT

A reminder call subscriber with charging is vacant.

11118 REMINDER SUBSCRIBER WITH NO CHARGING IS RESERVED

A reminder call subscriber with no charging is reserved.

11119 PARALLEL AD&C SUBSCRIBER

The AD&C subscriber is a parallel one.

11120 PARALLEL REMINDER CALL SUBSCRIBER WITH CHARGING

A parallel reminder call subscriber who has charging.

11121 PARALLEL REMINDER CALL SUBSRIBER WITH NO CHARGING

A parallel reminder call subscriber who has no charging.

11122 BTS NAME ALREADY IN USE OR ILLEGAL

A BTS name must be unique in the BSC. It may consist of allowed char-acters only.

11123 INCORRECT DEFAULT SERVICE NUMBER

Incorrect operators default service number.

11124 TSC (TRX) AND BCC (BTS) VALUES MUST BE EQUAL UNDER BCF

The Training Sequence Codes of the TRXs and the BTS Colour Codes of the BTSs must be equal under the BCF.

11125 NO SERVICE PROFILE HAS BEEN ATTACHED TO OSI APPLICA-TION

There is no service profile attached to the given OSI application.

11126 CONFLICT BETWEEN GIVEN AND ATTACHED OSI APPLICATION SERVICE PROFILE

There is a conflict between the given service profile type and the service profile type attached to the OSI application, e.g. the OSI application is a Q3 application (CMISE) and the user is modifying the VT mode: the parameters are mutually exclusive.

Page 147: DX Error Messages

DN987378Issue 24-0

147

General Error Messages of System DX error messages

Id:0900d8058077e097

11127 TIMESLOT OF ET IS ALREADY USED BY ANOTHER RADIO CHANNEL

There has been an attempt to use a timeslot which is already used by another radio channel.

11128 SIGNALLING UNIT IS FULL, NO MORE TRANSCEIVERS CAN BE CREATED IN SAME UNIT

The maximum number of transceivers allowed in the signalling unit has been reached. A D-channel in another signalling unit should be used.

11129 D-CHANNEL IS ON DIFFERENT PCM THAN RADIO TIME SLOTS

The radio time slots of a TRX must be created on the ET-PCM that contains the D-channel.

11130 DEFAULT SERVICE NUMBER IS IN USE

The default service number cannot be removed if an operator is using it.

11131 OMOLIB MEMORY MANAGEMENT ERROR

OMOLIB did not find the memory management data structure regis-tered for the current process.

11132 PREPROCESSOR LOADING IN PROGRESS

The loading of the preprocessor unit is in progress.

11133 PREPROCESSOR LOADING TIME OUT

The total time supervision of the loading of the preprocessor unit has expired.

11134 PREPROCESSOR LOADING FAILURE

The loading of the preprocessor failed.

11135 GIVEN UNIT IS NOT IN ACTIVE STATE

The given unit is not in the active state. The user can create an OSI application only for an active unit.

11136 CREATION OF BROADBAND FR ACCESS FAILED

This error code is generated by FBBASE upon an unsuccessful attempt to create a new FR access.

11137 NO FREE DLCI AVAILABLE

Occurs when an attempt is made to reserve a virtual channel from the FBBASE for an access in which all the DLCI values are currently in use.

11138 NO FREE ACCESS IDENTIFIER

Occurs when an attempt is made to reserve an access identifier from FBBASE.

11139 ATM TRUNK ACCESS DOES NOT EXIST

This code is generated in response to an ATM trunk related request for which an access does not exist.

11140 ATM VIRTUAL CHANNEL EXISTS

Indicates that a certain ATM virtual channel already exists.

11141 ATM VIRTUAL CHANNEL DOES NOT EXIST

Indicates that a certain ATM virtual channel does not exist.

Page 148: DX Error Messages

148 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11142 BROADBAND ROUTE DOES NOT EXIST

This code is generated in response to requests relating to routes that do not exist.

11143 BROADBAND FRAME RELAY ROUTE UNAVAILABLE

This code is generated in response to requests relating to unavailable routes.

11144 VIRTUAL PATH EXISTS FOR ACCESS

This error code indicates that there remains at least one reserved ATM virtual path for an access.

11145 ATM ROUTE STILL EXISTS FOR THE DLCI

This code is generated when an attempt is made to release a DLCI for which there remains at least one reserved ATM route.

11146 ATM TRUNK ACCESS NOT DEACTIVATED

An ATM trunk access has not been deactivated.

11147 ATM TRUNK ACCESS NOT ACTIVATED

An ATM trunk access has not been activated.

11148 FRAME RELAY TRUNK ACCESS NOT ACTIVATED

A Frame Relay trunk access has not been activated.

11149 ATM TRUNK ACCESS IS USED BY VIRTUAL CONNECTION

A virtual connection exists for the ATM trunk access.

11150 DIGITS NOT STORED FOR CALL BACK

If no call has been received whose subscriber number was stored, or the identity of subscriber A is incomplete, this error code is used.

11152 NUMBER OF FRAME UNITS IS NOT CONSISTENT WITH BTS DATABASE

Number of FUs in the configuration message is not consistent with the BTS HW database.

11153 DATABASE DOES NOT EXIST IN BTS

A BTS does not have an HW database.

11154 NUMBER OF CARRIER UNITS IS NOT CONSISTENT WITH BTS DATABASE

The number of carrier units in the configuration message is not consis-tent with the BTS HW database.

11155 DATABASE HAS BEEN CREATED WITH OLD MMI VERSION

A BTS HW database has been created using an old version of the OMU MMI.

11156 MESSAGE CONTAINS INVALID OBJECT TYPE

The message contains an invalid object type.

11157 NO RESPONSE FROM BTS WITHIN TIME LIMIT

A BTS does not respond within time limit.

11158 NEGATIVE ACKNOWLEDGEMENT FROM BTS

Page 149: DX Error Messages

DN987378Issue 24-0

149

General Error Messages of System DX error messages

Id:0900d8058077e097

A BTS has sent a negative acknowledgement to the BSC.

11159 PREVIOUS BTS CONFIGURATION IN PROGRESS

The previous configuration of a BTS is still in progress.

11160 CONFIGURATION DID NOT END DURING TIME SUPERVISION

The BSC did not receive the conf_completed message within time supervision.

11161 BTL IS BUSY DUE TO PREVIOUS RECOVERY ACTION

BTLARM is busy due to a previous recovery action.

11162 NUMBER OF COMMON DIGITS IS NOT THE SAME

The amount of common digits in the global and MSN number is not the same.

11163 BCF SOFTWARE DOWNLOAD MAXIMUM TIME EXPIRED

The maximum time defined for the BCF software download has expired.

11164 BCF HAS NOT REQUESTED CONFIGURATION DATA WITHIN DEFINED TIME LIMIT

A BCF has not requested a configuration within the defined time limit from the BSC after the SW download.

11165 RADIO NETWORK CONFIGURATION MANAGEMENT ACKNOWL-EDGEMENT TIME-OUT

The radio network configuration management (the GUPDAT program block) has not sent an acknowledgement message within the defined time limit.

11166 BTS O&M LINK HAS NOT BEEN ESTABLISHED WITHIN DEFINED TIME LIMIT

The BTS recovery system in the BSC has not been informed about the establishment of the BTS O&M link (to working state) within the defined time limit.

11167 BTS OMU HAS NOT BEEN STARTED WITHIN DEFINED TIME LIMIT

The BTS OMU has not sent the BTS_OMU_STARTED_S message (1252) to the BSC within the defined time limit.

11168 COPYING CLASS DOES NOT EXIST

A Frame Relay meters disk-copying class does not exist.

11169 COPYING CLASS IS USED FOR WEEKDAYS OR SPECIAL DAYS

A Frame Relay meters disk-copying class is used for weekdays or for special days.

11170 SPECIAL DAY DOES NOT EXIST

A Frame Relay meters disk-copying special day does not exist.

11171 SPECIAL DAY EXISTS

A Frame Relay meters disk-copying special day already exists.

11172 METER GROUP DOES NOT EXIST

A Frame Relay disk-copying meter group does not exist.

11173 METER GROUP ALREADY EXISTS

Page 150: DX Error Messages

150 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The Frame Relay meters disk-copying meter group already exists.

11174 METER DOES NOT EXIST

A meter does not exist in the Frame Relay meters disk-copying meter group.

11175 METER ALREADY EXISTS

A meter already exists in the Frame Relay meters disk-copying meter group.

11176 USER ACCESS ASSOCIATED WITH METER GROUP

A Frame Relay user access is associated with a Frame Relay meters disk-copying meter group.

11177 FR METER GROUP NAME CONFLICT

There is a conflict in the names of the Frame Relay meters disk-copying meter groups.

11178 LAST METER IN METER GROUP NOT REMOVED

The last meter in a Frame Relay meters disk-copying meter group cannot be removed.

11179 ACCESS TO NETWORK ELEMENT IS DENIED

Access to the network element is denied due to insufficient access rights.

11180 INCORRECT FREQUENCY BAND USED

Frequency bands are not compatible.

11181 SIGNALLING FROM RING TO LOOP DID NOT SUCCEED IN LIDN

Signalling from RING to LOOP did not succeed in LIDN.

11182 SIGNALLING FROM TEST TO ALARM DID NOT SUCCEED IN LIDN

Signalling from TEST to ALARM did not succeed in LIDN.

11183 TEST CONNECTION TIME EXCEEDED

The test connection time on the LIDN plug-in unit has been exceeded.

11184 FAILURE IN LIDN SIGNALLING

Subscriber signalling test on the LIDN plug-in unit was unsucessfull.

11185 PERMANENT VIRTUAL CIRCUITS NOT ASSOCIATED WITH CHANNEL GROUP

The Permanent Virtual Circuits (PVC) are not associated with a channel group.

11186 CHANNELS USING ETHERNET TERMINAL ARE NOT ASSOCIATED WITH CHANNEL GROUP

The physical channels which use the Ethernet terminal are not associ-ated with a channel group.

11187 LINE TERMINAL ALREADY LOOPED

The line terminal is already looped.

11188 LINE TERMINAL NOT LOOPED

The line terminal is not looped.

Page 151: DX Error Messages

DN987378Issue 24-0

151

General Error Messages of System DX error messages

Id:0900d8058077e097

11189 PREANNOUNCEMENT SET

A preannouncement has been set for the destination.

11191 NO PREANNOUNCEMENT

There is no preannouncement on the destination.

11192 PRE-ANNOUNCEMENT NOT LAST DESTINATION ALTERNATIVE

The pre-announcement is not the last alternative on the destination.

11202 SUBSCRIBER NUMBER WITH DOUBLE NUMBER

Subscriber number with double telephone number.

11204 VACANT SUBSCRIBER NUMBER WITHOUT COUNTERS

A subscriber number without counters is vacant.

11205 INCORRECT DOUBLE TELEPHONE NUMBER

A double subscriber number is incorrect.

11206 NOT A D-CHANNEL ET UNIT

There has been an effort to do something possible only with an ET unit that has a D-channel.

11207 ET UNIT IS IN TRANSPARENT MODE

The ET unit is in the transparent mode, which means e.g. that only some of the trunk PCM error statistics are possible.

11208 FOLLOW-ME SUBSCRIBER

The subscriber type is "follow me".

11209 ROUTINE TEST REPORTING BUSY

Routine test reporting is busy. Try reporting later.

11210 MESSAGE BUS SENDING IS NOT POSSIBLE

The MBIF plug-in unit is not ready to send messages.

11211 MB SENDING DID NOT SUCCEED

The sending of a message bus message was not successful.

11212 NO QUIT BYTE

The requested state and acknowledgement byte has failed to arrive from the receiving MBIF plug-in unit, due to an error in the sending of a message bus message.

11213 MB HEADER RECEIVING ERROR

When receiving a message bus message, an error was detected in the reading of the header of the message.

11214 MB MESSAGE RECEIVING ERROR

When receiving a message bus message, an error was detected after the reading of the header.

11215 BCCH ALLOCATION OPTION IS NOT IN USE IN BSC

The BCCH allocation option is not in use in the BSC.

11216 DISTURBANCE MEASUREMENTS ARE NOT POSSIBLE IN CURRENT MODE

Page 152: DX Error Messages

152 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

This error appears when the MML user tries to obtain measurements about disturbances of the PCM line of ET2E while the set mode does not provide these measurements.

11217 FRAMING ERROR MEASUREMENTS ARE NOT POSSIBLE IN CURRENT MODE

This error appears when the MML user tries to obtain framing error measurements of the PCM line of ET2E while the set mode does not provide these measurements.

11218 SLIP MEASUREMENTS ARE NOT POSSIBLE IN CURRENT MODE

This error appears when the MML user tries to obtain slip measure-ments of the PCM line of ET2E while the set mode does not provide these measurements.

11219 INCORRECT NMT IDENTIFICATION

A DAXnode subscriber is not found by NMT identification.

11220 INCORRECT PCM-TSL

A DAX subscriber is not found on the basis of his PCM-TSL.

11221 TSC (BCCH OR PBCCH TRX) AND BCC (CELL) VALUES MUST BE EQUAL

The Training Sequence Codes of the TRXs and the BTS Colour Code of the BTS must be equal.

11222 MBIF NOT USABLE

There is no MBIF plug-in unit, or it is unavailable for some other reason.

11223 CALL RETURN NUMBER

A call return number.

11224 PARALLEL ORDINARY SERVICE NUMBER

A parallel ordinary service number.

11225 PARALLEL CX SERVICE NUMBER

A parallel Centrex service number.

11226 PARALLEL RSU PBX NUMBER

A parallel PBX number of an RSU.

11227 PARALLEL FREE SUBSCRIBER NUMBER WITHOUT SUBSCRIBER METERS

There is a parallel free subscriber number without subscriber meters.

11228 PARALLEL DOUBLE SUBSCRIBER NUMBER

Parallel double subsciber number.

11229 ADMINISTRATIVE STATE OF THE OBJECT IS INCORRECT

The administrative state of the object in the radio network database is unsuitable for the requested operation.

11230 MAFILE OF OTHER PACKAGE IN DIRECTORY NOT OK

The MAFILE file of the other package in the directory is not OK, or it cannot be read.

Page 153: DX Error Messages

DN987378Issue 24-0

153

General Error Messages of System DX error messages

Id:0900d8058077e097

11231 PACKAGE NOT IDENTICAL WITH OTHER PACKAGE IN DIREC-TORY

The package is not the same as the other package in the directory.

11232 EXISTING DIRECTORY TOO SMALL

The existing directory is too small.

11233 UNIT TYPE TO DISK BIT MASK CONVERSION LIBRARY ERROR

The conversion - by means of a library program - of a unit type to a disk bit mask has failed.

11234 FOLLOW ME SUBSCRIBER

This is a FOLLOW ME subscriber.

11235 FOLLOW ME SUBSCRIBER VACANT

This FOLLOW ME subscriber is vacant.

11236 FOLLOW ME SUBSCRIBER RESERVED

FOLLOW ME subscriber is reserved.

11237 PARALLEL FOLLOW ME SUBSCRIBER

Parallel FOLLOW ME subscriber.

11238 BTS POWER CONTROL PARAMETERS NOT FOUND IN DATABASE

BTS power control parameters have not been created into the radio network database.

11239 BTS HANDOVER CONTROL PARAMETERS NOT FOUND IN DATABASE

BTS handover control parameters have not been created into the radio network database.

11240 COMMAND PARTLY SUCCESSFUL: VLR NOT UPDATED

The data cannot be transfered to VLR correctly. The MAP interface rejects the given operation. However, the data has been stored in the HLR database.

11241 SYMBOL NOT FOUND

Symbol is not found.

11242 AMBIGUOUS SYMBOL NAME

Symbol name is ambiguous.

11243 AMBIGUOUS PACKAGE ID

The given software package identification is ambiguous.

11244 ILLEGAL DESTINATION NETWORK ELEMENT

The given network element is not a legal destination for a remote SW package transfer.

11245 NETWORK ELEMENT NOT FOUND

Network element is not found.

11246 TRANSFER IN PROGRESS

Transfer is in progress.

11247 TRANSFER NOT IN PROGRESS

Page 154: DX Error Messages

154 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Transfer is not in progress.

11249 BTS NAME IS ILLEGAL

A BTS name may consist of allowed characters only.

11250 BTS NAME ALREADY IN USE

A BTS name must be unique in the BSC.

11251 REQUESTED OPERATION NOT SUPPORTED BY THE DEFINED SITE TYPE

The requested operation is not possible with the defined site type. The site type is a parameter of the BCF object.

11252 REQUESTED OPERATION IS NOT ALLOWED TO FLOATING-TYPE TRX

The requested operation is not possible with TRX of the floating type. The TRX type is a parameter of a TRX object.

11253 RF HOPPING BTS USING MA LIST MUST BE LOCKED

Modification is possible only if the administrative state(s) of the RF (Radio Frequency) hopping BTS(s) using the MA list is (are) LOCKED.

11254 OPERATION REQUIRES THAT RF HOPPING BTS MUST BE LOCKED

The operation was rejected because an RF hopping BTS was not locked. The admistrative state of the BTS must be LOCKED.

11255 SIMULTANEOUS BB AND RF HOPPING IS NOT ALLOWED UNDER BCF

The operation was rejected because in a BCF there are BTSs with simultaneously defined BB (Base Band) and RF (Radio Frequency) hopping.

11256 FREQUENCY OF CELLS BCCH TRX IS NOT ALLOWED TO BE IN CELLS MA LIST

An operation was rejected because the frequency of BCCH TRX of a cell is in the MA list of the cell.

11257 INCORRECT FREQUENCY FOR USED BAND

The frequency does not belong to the specified (GSM or DCS) band.

11258 BCCH TRX ARFCN IS NOT ALLOWED TO BE IN MA LIST OF BTS

In RF (Radio Frequency) hopping it is not allowed to have an ARFCN of a BCCH TRX in the MA list of a BTS.

11259 TOO FEW ARFCNS IN MA LIST USED BY CELL

The number of RF-hopping TRXs and Maio Offset (MO) and Maio Step (MS) parameters affect the number of frequencies on the MA list.

11260 MA LIST NOT FOUND IN RNW DATABASE

The MA list must be created before any BTS can be attached to it.

11261 MA LIST IS STILL USED BY SOME BTS

An MA list cannot be deleted if it is used by a BTS.

11262 MA FREQUENCY LIST IS FULL

Page 155: DX Error Messages

DN987378Issue 24-0

155

General Error Messages of System DX error messages

Id:0900d8058077e097

No new frequency can be added to the MA list because the frequency list is full.

11263 ADMINISTRATIVE STATE OF HOPPING CELL MUST BE LOCKED

The operation requires that the hopping BTS is locked.

11264 FR USER ACCESS NOT PASSIVATED

A Frame Relay user access has not been deactivated.

11265 FRAME RELAY USER ACCESS NOT ACTIVATED

A Frame Relay user access has not been activated.

11266 BCC+NCC+BCCH TRX FREQUENCY NOT UNIQUE IN ADJACENCY DEFINITIONS

The BCC + NCC + BCCH TRX frequency parameter combination must be unique for each member in the neighbour list of a cell. The list for each cell is collected from the neighbour definitions of the cell and the list is used in MS measurements. The BCC + NCC + BCCH TRX fre-quency uniqueness can be checked with the adjacent cell MML.

11267 NO MORE REQUESTED DATA

There is no more data. All data has already been given.

11268 DIRECT DIALLING-IN HAS BEEN SET

The DDI facility has been set for the subscriber.

11269 UNKNOWN TRX ID

A configuration mismatch has been found between GUPDAT and Abis-signalling program blocks, or a message was corrupt.

11270 UNKNOWN BTS ID

A configuration mismatch has been found between GUPDAT and Abis-signalling program blocks, or a message was corrupt.

11271 UNKNOWN BCF ID

A configuration mismatch has been found between GUPDAT and Abis-signalling program blocks, or a message was corrupt.

11272 MOBILE ALLOCATION NOT AVAILABLE

Mobile allocation table length is zero.

11273 CELL ALLOCATION NOT AVAILABLE

Cell allocation table length is zero.

11274 TOO MANY VALUES IN MOBILE ALLOCATION TABLE

Mobile allocation table length is greater than allowed.

11275 TOO MANY VALUES IN CELL ALLOCATION TABLE

Cell allocation table length is greater than allowed.

11276 ZERO VALUE IN MOBILE ALLOCATION TABLE

Zero frequency value in mobile allocation table.

11277 ZERO VALUE IN CELL ALLOCATION TABLE

Zero frequency value in cell allocation table.

11278 INVALID VALUE IN MOBILE ALLOCATION TABLE

Page 156: DX Error Messages

156 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Invalid arfcn value in mobile allocation table.

11279 INVALID VALUE IN CELL ALLOCATION TABLE

Invalid arfcn value in cell allocation table.

11280 IN MOBILE ALLOCATION TABLE TWO ARFCN HAVE SAME VALUE

In mobile allocation table two arfcn have same value.

11281 IN CELL ALLOCATION TABLE TWO ARFCN HAVE SAME VALUE

In cell allocation table two arfcn have same value.

11282 ZERO FREQUENCY VALUE IN ABIS INTERFACE INTERNAL ARFCN TABLE

In Abis interface internal arfcn table has zero frequency value.

11283 TOO MANY ARFCN VALUES OR DIFFERENCE BETWEEN GREATEST AND SMALLEST VALUES IS TOO BIG

Overflow in Abis interface internal arfcn table.

11284 TEMPORARILY OVERLOAD

There are too many TRXs in the TRX list of the conf_data message. Check the TRX count.

11285 AOM SLAVE HAS NOT ANSWERED SUPERVISION MESSAGE TO AOMPRB MASTER

AOM slave has not answered supervision message to AOMPRB master.

11286 MAXIMUM AMOUNT OF BCF IDS IN USE

NO MORE SPACE TO SAVE BCF INFORMATION IN AOMPRB

11287 MAXIMUM AMOUNT OF TRX IDS IN USE

Maximum amount of trx ids in use.

11288 INVALID RADIO TSL TYPE DETECTED

Invalid radio tsl type detected.

11289 CREATION OF HAND HAS FAILED IN ABIPRB

Creation of hand has failed in ABIPRB, probably because of operation system error.

11290 DELETION OF HAND HAS FAILED IN ABIPRB

Deletion of hand has failed in ABIPRB, probably because of operation system error.

11291 HAND CREATION PROCEDURE HAS FAILED IN ABIPRB

Hand Creation procedure has failed in ABIPRB, probably because of operation system error.

11292 CCCH HAND HAS NOT RESPONDED TO REQUEST TASK

CCCH hand has not responded to request task.

11293 SDCCH OR TCH HAND HAS NOT RESPONDED TO REQUEST TASK

SDCCH or TCH hand has not responded to request task.

11294 DELETION OF TRX HAS FAILED

Page 157: DX Error Messages

DN987378Issue 24-0

157

General Error Messages of System DX error messages

Id:0900d8058077e097

Deletion of TRX has failed because PXRECE has not responded to request task.

11295 TOO MANY ARFCN VALUES (B_M_0)

Creation of bm0 format fails because of too many arfcn values.

11296 TOO MANY ARFCN VALUES (V_B_M)

Creation of vbm fails because of too many arfcn values.

11297 TOO MANY ARFCN VALUES (R256)

Creation of range 256 fails because of too many arfcn values.

11298 TOO MANY ARFCN VALUES (R512)

Creation of range 512 fails because of too many arfcn values.

11299 THE DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO HIGH (B_M_0)

Creation of bm0 fails because the difference between the greatest and the smallest arfcn value is too high.

11300 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO HIGH (V_B_M)

Creation of vbm fails because difference between greatest and smallest arfcn value is too high.

11301 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO HIGH (R256)

Creation of range 256 fails because difference between greatest and smallest arfcn value is too high.

11302 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO HIGH (R512)

Creation of range 512 fails because difference between greatest and smallest arfcn value is too high.

11303 WRONG PARAMETER VALUE IN CONF DATA MESSAGE

WRONG PARAMETER VALUE IN CONF DATA MESSAGE.

11304 TOO MANY TRXS ON THE BCF

There are too many TRXs in the TRX list of the conf_data message. Check the TRX count.

11305 TEMPORARY OVERLOAD, NO RESOURCES AVAILABLE

There is a temporarily overload. No resource are available. Try again later.

11306 TEMPORARILY OVERLOAD. NO RESOURCE AVAILABLE.

Temporarily overload. No resource available. Try again later.

11309 SUBSCRIBER PASSIVE

The WLL subscriber does not respond to a call attempt. The subscribers terminal may be faulty or just switched off.

11310 APPLICATION CREATION IN DATABASE FAILED

The creation of a new application object in the OEDATA database has failed.

Page 158: DX Error Messages

158 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11311 APPLICATION ALREADY EXISTS IN DATABASE

The application already exists in the OEDATA database.

11312 APPLICATION DOES NOT EXIST IN DATABASE

The application does not exist in the OEDATA database.

11313 APPLICATION IS UNLOCKED

The administrative state of an application object in the OEDATA database is unlocked.

11314 SERVICE PROFILE CREATION IN DATABASE FAILED

The creation of an application service profile object in the OEDATA database has failed.

11315 SERVICE PROFILE ALREADY EXISTS IN DATABASE

The application service profile already exists in the OEDATA database.

11316 SERVICE PROFILE DOES NOT EXIST IN DATABASE

The application service profile does not exist in the OEDATA database.

11317 SELECTOR SET CREATION IN DATABASE FAILED

The creation of an additional selector set object (of an application) in the OEDATA database has failed.

11318 SELECTOR SET ALREADY EXISTS IN DATABASE

The additional selector set of the application already exists in the OEDATA database.

11319 SELECTOR SET DOES NOT EXIST IN DATABASE

An additional selector set of an application does not exist in the OEDATA database.

11320 NETWORK ADDRESS CREATION IN DATABASE FAILED

The creation of a network address object in the OEDATA database has failed.

11321 NETWORK ADDRESS ALREADY EXISTS IN DATABASE

The network address already exists in the OEDATA database.

11322 NETWORK ADDRESS DOES NOT EXIST IN DATABASE

The network address does not exist in the OEDATA database.

11323 NSAP CREATION IN DATABASE FAILED

The creation of an NSAP (Network Service Access Point) object in the OEDATA database has failed.

11324 NSAP ALREADY EXISTS IN DATABASE

The Network Service Access Point (NSAP) already exists in the OEDATA database.

11325 NSAP DOES NOT EXIST IN DATABASE

The Network Service Access Point (NSAP) does not exist in the OEDATA database.

11326 NSAP IS UNLOCKED

Page 159: DX Error Messages

DN987378Issue 24-0

159

General Error Messages of System DX error messages

Id:0900d8058077e097

The administrative state of an NSAP object in the OEDATA database is unlocked.

11327 CLNS CREATION IN DATABASE FAILED

The creation of a new CLNS (Connectionless Network Service) object in the OEDATA database has failed.

11328 CLNS ALREADY EXISTS IN DATABASE

The CLNS (Connectionless Network Service) already exists in the OEDATA database.

11329 CLNS DOES NOT EXIST IN DATABASE

The CLNS (Connectionless Network Service) does not exist in the OEDATA database.

11330 CLNS IS UNLOCKED

The administrative state of the CLNS object in the OEDATA database is unlocked.

11331 CREATION OF LINKAGE IN DATABASE FAILED

The creation of a linkage object in the OEDATA database has failed.

11332 LINKAGE ALREADY EXISTS IN DATABASE

The linkage already exists in the OEDATA database.

11333 LINKAGE DOES NOT EXIST IN DATABASE

The linkage does not exist in the OEDATA database.

11334 LINKAGE IS UNLOCKED

The administrative state of a linkage object in the OEDATA database is unlocked.

11335 NETWORK ADDRESS IS IN USE

The network address is attached to an application and cannot be deleted.

11336 NSAP ATTACHED TO NETWORK ADDRESS

The network address cannot be deleted, because one or more NSAPs are attached to it.

11337 SEARCH MASK IS NOT OK

The search mask used in inquiries about the OEDATA database is not OK.

11338 PARALLEL FAULTMANS RINGBACK SUBSCRIBER

The faultmans ringback subscriber has a parallel number.

11339 FAULTMANS RINGBACK SUBSCRIBER NUMBER BUSY

The faultmans ringback subcriber number is busy.

11340 FAULTMANS RINGBACK SUBSCRIBER IS FREE

The faultmans ringback subscriber number is free.

11341 FAULTMANS RINGBACK SUBSCRIBER

Faultmans ringback subscriber.

11342 OBJECT ID OUT OF LIMITS

Page 160: DX Error Messages

160 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An objects ID value is either too low (BTS = 0, TRX = 0) or too high (BTS > 80H, TRX > 10H, TSL > 7H).

11343 BTS ALREADY EXISTS

The BTS in question has already been created.

11344 GIVEN BTS DOES NOT EXIST

The given BTS has not been created in the configuration.

11345 MAXIMUM NUMBER OF TRXS ALREADY CREATED

All possible TRXs have already been created, i.e. the maximum number of TRXs has been reached.

11346 TRX ALREADY EXISTS

The TRX in question has already been created.

11347 GIVEN TRX DOES NOT EXIST

The given TRX has not been created in the configuration.

11348 TRX IN WRONG STATE FOR THE OPERATION

The given TRX is not in the right state for the operation in question.

11349 GIVEN TRX ALREADY IN WORKING STATE

The given TRX is already in the WORKING state.

11350 WRONG TSL TYPE FOR THE OPERATION

The type of the given TSL is not appropriate for the intended operation.

11351 GIVEN TSL ALREADY IN WORKING STATE

The given TSL is already in the WORKING state.

11352 TRX NOT IN WORKING STATE

The given TRX is not in the WORKING state, as expected in the oper-ation.

11353 TSL NOT IN WORKING STATE

The given TSL is not in the WORKING state, as expected in the opera-tion.

11354 BTS ALARM SYSTEM FILE IS FULL

The Alarm History FIle of a BTS is full.

11355 BTS ALARM HISTORY FILE IS FULL IN BCF

The Alarm History File of a BTS is full in the BCF.

11356 BTS ALARM SYSTEM FILTER BUFFER OVERFLOW

There is an overflow in the BTS alarm system filter buffer.

11357 BTS ALARM SYSTEM OUTPUT BUFFER OVERFLOW

There is an overflow in the BTS alarm system output buffer.

11358 CPE PASSIVE

A Customer Premises Equipment (CPE) does not respond to call attempts. The subscriber terminal may be faulty or just switched off.

11359 DIRECTED RETRY OPTION IS NOT IN USE IN BSC

Page 161: DX Error Messages

DN987378Issue 24-0

161

General Error Messages of System DX error messages

Id:0900d8058077e097

The directed retry feature, which is used in the call set-up phase when assigning (when congestion occurs) a mobile station to a traffic channel in a cell other than the serving cell, is not supported in the BSC.

11360 C2 CELL RESELECTION OPTION IS NOT IN USE IN BSC

The C2 cell reselection feature is not supported in BSC. The purpose of C2 cell reselection is to control cell reselection of mobile stations in idle status.

11361 FACCH CALL SET-UP OPTION IS NOT IN USE IN BSC

The FACCH call set-up feature is not supported in the BSC.

11362 REMOTE DEGRADATION OF BTS SERVICE OPTION IS NOT IN USE IN BSC

The remote degradation of BTS service under transceiver shutdown is not supported in the BSC.

11363 ADMINISTRATIVE STATE IS NOT ONLY ATTRIBUTE TO BE MODIFIED

The user tries to modify both the administrative state and other attri-butes at the same time.

11364 REQUESTED OPERATION MAY BE PARTLY SUCCESSFUL DESPITE ERROR

The requested operation may be partly successful despite the error or errors that occured during the handling of the operation.

11365 DATABASE FORMAT IS NOT SUPPORTED BY BTS

The database format is not supported by the BTS.

11366 NO SUCH CLOSED USER GROUP

There was no such closed user group.

11367 FATAL ERROR DURING FLASH OPERATION

A fatal error occurred during the flash operation.

11368 MEMBER IN CLOSED USER GROUP

There is a member in a closed user group.

11369 ILLEGAL FILE TYPE

Illegal file type.

11370 FLASH MEMORY HAS NOT BEEN SEGMENTED

The flash memory of a BTS has not been segmented.

11371 CELL CONFIGURATION MISMATCHES WITH THE CURRENT HARDWARE

The cell configuration does not match with the current hardware.

11372 INVALID HOPPING MODE DUE TO HARDWARE LIMITATIONS

The hopping mode is invalid, due to hardware limitations.

11373 NO FLOATING TRX INSTALLED AT BTS SITE

No floating TRX is installed at the BTS site.

11374 HOPPING BTS HAS INCORRECT ADMINISTRATIVE STATE FOR REQUESTED TASK

Page 162: DX Error Messages

162 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

A Base Station with frequency hopping in use has an administrative state which is not suitable for the requested task. Certain configuration changes in a hopping cell are not allowed when the BTS is in the UNLOCKED state.

11375 UNKNOWN BASE STATION ALARM V-PARAMETERS

The V-parameters of the base station alarm do not exist in the DEFBSA file.

11376 FOLLOW ME SUBSCRIBER ALREADY EXISTS

A Follow Me subscriber for this area code already exists.

11377 FAULTMANS RINGBACK SUBSCRIBER ALREADY EXISTS

A Faultmans Ringback subscriber for this area code already exists.

11378 CLOSED USER GROUP RESERVED

The closed user group has already been reserved.

11379 ALL SUBSCRIBERS NOT AVAILABLE

The call generator needs subscriber pairs, and all subscribers have not been created.

11380 CALL GENERATOR NOT STARTED

The call generator did not start.

11381 BAD OUTGOING ATM LINE NUMBER

An outgoing ATM line number exceeds the allowed limits. Bad connec-tion message data is received, or the HW configuration data differs from the AXRMGR database data.

11382 BAD INCOMING ATM LINE NUMBER

An incoming ATM line number exceeds the allowed limits. Bad connec-tion message data is received, or the HW configuration data differs from the AXRMGR database data.

11383 SWCOP FIFO IS RESERVED

The SWCOP FIFO is reserved during an attempt to make a connection. Another process has reserved the FIFO for data transfer.

11384 SWCOP WRITE BUFFER FULL

The SWCOP unit is not reading connection data from the FIFO. The SWCOP software is either busy or faulty.

11385 NO CONNECTION ACKNOWLEDGEMENT FROM SWCOP

The SWCOP unit is not responding to the connection message. The FIFO transmission failed, bad data was read from FIFO, or the SWCOP unit is faulty.

11386 SWCOP RESTART FAILURE

Restarting the SWCOP unit failed. The unit is missing or faulty, or bad HW configuration data is to blame.

11387 SWCOP UNIT NOT INITIALISED

There was an attempt to make a connection through an unitialised SWCOP unit. The unit is restarted or HW configuration changes are made without reinitialisations.

Page 163: DX Error Messages

DN987378Issue 24-0

163

General Error Messages of System DX error messages

Id:0900d8058077e097

11388 ASWI UNIT NOT INITIALISED

There was an attempt to make a connection to an unitialised ASWI unit. The unit is reset or HW configuration changes are made without reini-tialising the unit.

11389 CONNECTION TYPE MISMATCH

There has been a type mismatch on the connection data and/or the line types. There was an attempt to make a VP connection on a VC line or vice versa.

11390 PARITY ERROR ON CONNECTION

The connection failed on the ASWI unit. Hardware failure.

11391 CONNECTION MEMORY CHECK FAILURE

Data read from the ASWI connection memory differs from written con-nection data. The connection failed. ASWI HW is faulty.

11392 ASWI INITIALISATION FAILED

ASWI unit initialisation has failed. The unit is missing, or bad, or HW configuration data is bad.

11393 ATM CONNECTION TYPE MISMATCH

The attempted transaction was incompatible with the current configura-tion of the ATM switch matrix (ASWI plug-in unit). For example, a request has been made for a Virtual Channel Connection on a line set to handle Virtual Path Connections.

11394 HW DATABASE FILE(S) ALREADY EXISTS

The BCF HW database file(s) has already been found on the disk(s) of the BSC.

11395 NO HW DATABASE DOWNLOAD REQUEST FROM BCF

BTDOWN has not received a HW database file download request from BCF (via AOMPRB).

11396 INCORRECT HW DATABASE DOWNLOAD REQUEST FROM BCF

BTDOWN has received an incorrect HW database download request from BCF (via AOMPRB). There might be a conflict between the BCF type and the type of the requested file.

11397 NO FILE RECORD FROM BCF

The HW database uploading has been interrupted because of a missing file record from BCF (via AOMPRB).

11398 INCORRECT FILE RECORD FROM BCF

BTDOWN has received an incorrect file record from BCF (via AOMPRB). The location of the record in the file may be unknown.

11399 ERROR IN HW DATABASE FILE LOADING

A HW database file loading operation has been interrupted by an internal error in BTDOWN.

11400 OPERATION NOT SUCCESSFUL ON BOTH DISKS

BTDOWN has failed in a disk operation on both disks in BSC.

11401 ONGOING SOFTWARE DOWNLOAD OPERATION IN BCF

Page 164: DX Error Messages

164 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The HW database operation is denied because of ongoing software package downloading in the same BCF.

11402 HW DATABASE OPERATION INTERRUPTED BY SW OPERATION

The HW database operation has been interrupted by an SW package download request.

11403 UNKNOWN BTS SITE TYPE

The type of BTS site (BCF) is unknown.

11404 SPARE UNIT IN RESTART STATE, TRY AGAIN

The spare unit was in the restarting state while the active unit was trying to make radio network configuration changes. Try again after the restarting of the spare unit is completed.

11405 PARAMETERS DO NOT COINCIDE

There is an inconsistency between the parameters given in a command.

11406 INCORRECT BASE STATION STATE

The defined base station is not in such a working state as the given task requires.

11407 BASE STATION CHANNELS NOT OUT OF USE

The channels of the base station are not out of use, although the task requires it.

11408 INCORRECT BASE STATION CIRCUIT STATE

The defined base station circuit is not in such a working state as the given task requires.

11409 CORRESPONDING DSP IS FAULTY

The corresponding DSP of the SPU-U plug-in unit is faulty.

11410 NO RESPONSE FROM USAPRO

No acknowledgement has been received from the USAPRO program block to the DSP status inquiry.

11411 BASE STATION ET IS IN WRONG WORKING STATE

The base station ET is in the wrong working state.

11412 BASE STATION CIRCUIT NOT IN CONFIGURATION

The defined base station circuit does not belong to the radio network configuration.

11413 PCM NOT IN CONFIGURATION

The defined PCM does not belong to the radio network configuration.

11414 CIRCUIT NOT IN USE IN THIS BASE STATION

The base station circuit does not belong to the given base station.

11415 BASE STATION CIRCUIT ALREADY IN USE

The base station circuit which someone tried to add to the configuration is already in use.

11416 BASE STATION HAS CIRCUITS IN USE

The deletion of a base station is not possible because of circuits con-nected to the base station.

Page 165: DX Error Messages

DN987378Issue 24-0

165

General Error Messages of System DX error messages

Id:0900d8058077e097

11417 NO CIRCUITS CONNECTED TO BASE STATION

Interrogation of base station circuits is not possible, because there are no circuits connected to the base station.

11418 CHANNEL NUMBER ALREADY IN USE

Adding or modifying a channel number was not possible, because the given channel number is already in use.

11419 CHANNEL NUMBER IS NOT IN USE

The given channel number is not in use.

11420 BASE STATION ALREADY EXISTS

The base station given in the adding or modifying command already exists.

11421 BASE STATION IS NOT IN CONFIGURATION

The specified base station does not belong to the radio network config-uration.

11422 DEFAULT BS NOT CREATED

The default base station values cannot be used in the creation of a new base station, because the default base station is not created.

11423 TRAFFIC AREA IS ALREADY IN CONFIGURATION

The specified traffic area is already in the configuration.

11424 TRAFFIC AREA NOT IN CONFIGURATION

The specified traffic area does not belong to the radio network configu-ration.

11425 BASE STATIONS STILL CONNECTED TO TRAFFIC AREA

Base stations are still connected to the traffic area that was specified in the deletion command.

11426 BASE STATION ALREADY DEFINED TO THIS TRAFFIC AREA

The base station specified belongs already to this traffic area.

11427 BASE STATION BELONGS TO NO TRAFFIC AREA

The specified base station does not belong to any traffic area.

11428 TRAFFIC AREA NUMBER ALREADY IN USE

The defined traffic area number is already in use.

11429 BASE STATION BELONGS TO ANOTHER TRAFFIC AREA

The defined base station belongs to another traffic area.

11430 DISK AND SPARE UNIT UPDATE FAILURE

Both disk and spare unit updating has failed.

11431 CALLING CHANNEL NOT IN BASE BAND

The defined calling channel limits are not within base band limits.

11432 USE OF ACCESS CHANNELS NOT POSSIBLE IN THIS BASE STATION

The use of access channels in this base station is impossible due to the radio network configuration.

Page 166: DX Error Messages

166 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11433 USE OF COMBINED CHANNELS NOT POSSIBLE IN THIS BASE STATION

The use of combined channels in this base station is impossible due to the radio network configuration.

11434 INAPPROPRIATE NUMBER OF DATA CHANNELS

There is an inappropriate number of data channels in this base station.

11435 BASE STATION HAS ONLY NECESSARY CIRCUITS LEFT

Circuits cannot be deleted, because the base station has only the nec-essary circuits left.

11436 BASE STATION HAS SUFFICIENT DDCS

The channel type cannot be changed, because the base station already has sufficient data channels.

11437 ONLY ONE CALLING CHANNEL POSSIBLE IN THIS BASE STATION

Only one calling channel is possible in this base station, due to the radio network configuration.

11438 INCORRECT CHANNEL NUMBER

The interrogating or modifying of a base station circuit state, using a channel number, has not succeeded because of an undefined channel number.

11439 BASE STATION DOES NOT HAVE ALL SUFFICIENT CHANNELS

The base station does not have all the channels it needs, so its working state cannot be changed to WO.

11440 BASE STATION HAS ALREADY ONE CHANNEL IN TEST USE

There was an attempt to add a test channel to a base station which already has one.

11441 NO BASE STATION BELONGS TO THIS TRAFFIC AREA

The defined task cannot be executed, because the defined traffic area has no base stations.

11442 NO MORE PCMS CONNECTED

All PCMs have been interrogated by the circuit state interrogation command. The last information on circuits was sent in the previous answer.

11443 NO MORE CIRCUITS OF THIS TYPE

All circuits of the given type have been interrogated by the circuit state interrogation command. Last information was sent in previous answer.

11444 NO MORE CONNECTED CIRCUITS LEFT

All circuits have been handled, when changing their states by command.

11445 NO MORE BASE STATIONS LEFT

All base stations have been handled, when interrogating them by using a command.

11446 CHANNEL STILL RESERVED

Page 167: DX Error Messages

DN987378Issue 24-0

167

General Error Messages of System DX error messages

Id:0900d8058077e097

Channel status is occupied.

11448 SUITABLE SUBDESTINATION NOT FOUND

CMREAD has not found a suitable subdestination from a destination.

11449 SUBDESTINATION OVERFLOW NOT ALLOWED - DESTINATION BARRED

It is not allowed to try another subdestination, or else the destination is barred.

11450 ATM USER ACCESS EXISTS

This error occurs when an attempt is made to create an ATM user access which already exists (e.g. the access identifier is already defined).

11451 ATM USER ACCESS DOES NOT EXIST

This error arises when a transaction is attempted for an ATM user access that does not exist.

11452 ATM USER ACCESS USED BY VIRTUAL CONNECTION

This error code is generated when an attempt is made to delete an ATM user access for which at least one virtual connection still exists.

11453 ATM USER ACCESS NOT INACTIVATED

Certain transactions can only be performed on an ATM user access which has been previously set to an inactive state. If such a transaction is attempted upon an active ATM user access it will result in the gener-ation of this error code.

11454 ATM USER ACCESS NOT ACTIVATED

An ATM user access has not been activated.

11455 STATE CHANGE FAILED

The changing of the administrative state of an object in the OEDATA database has failed.

11456 REMOTE MMI CONNECTION HANDLING SYSTEM BUSY (RETMMI PROGRAM BLOCK)

The RETMMI program block cannot create a new hand, yet the maximum number of hands has not been reached.

11457 NO FREE REMOTE MMI CONNECTIONS

The maximum number of remote MMI connections is already in use.

11458 UNFINISHED CONNECTION TO BCF EXISTS

A new connection cannot be established because there is still an unfin-ished operation in this BCF.

11459 ACKNOWLEDGEMENT MESSAGE FROM AOMPRB MISSING

The AOMPRB program block does not answer to a connection request.

11460 MEMBER OF PRIVATE ISDN NETWORK

The subscriber is a member of a private ISDN network.

11461 MEMBER OF PRIVATE ANALOGUE NETWORK

The subscriber is a member of an analogue private network.

Page 168: DX Error Messages

168 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11462 GROUP CALL NUMBER OF PRIVATE ISDN NETWORK

The number of the subscriber is the group call number of a private ISDN network.

11463 GROUP CALL NUMBER OF PRIVATE ANALOGUE NETWORK

The subscriber number is the group call number of a private analogue network.

11464 INCORRECT BASE STATION CHANNEL STATE

The defined base station channel is not in the working state that the given task requires.

11465 VIRTUAL PATH TABLE ERROR

The FR/ATM Connection Handling Program Block (FBHAND) main-tains a work table to manage the supply of virtual path routing data to the ATM Multiplexer Unit. This error is generated if in the course of updating the table a problem is encountered. An example of such a problem would be that the permitted ratio of ATM Multiplexer Units to Cell Relay Subscriber Units has been exceeded.

11466 SUBSCRIBER IS ALREADY A HUNTING GROUP MEMBER

The subscriber is already a member in a hunting group.

11467 SDCCH HANDOVER OPTION IS NOT IN USE IN BSC

The SDCCH Handover feature is not in use in the BSC.

11468 RXQUAL STATISTICS AND HANDOVER ADJACENT~CELL MEA-SUREMENT OPTION IS NOT IN USE IN BSC

The RXqual statistics and handover adjacent cell measurement features are not in use in the BSC.

11469 REMOTE INTERROGATION OF BTS SERIAL AND VERSION NUMBERS OPTION IS NOT IN USE IN BSC

The remote interrogation of the serial and version numbers of a BTS (HW configuration) via the Q3 interface is not in use in the BSC.

11470 LOCAL COPY SERVICE WAS PARTLY SUCCESSFUL

The OVFSRP program block has received a local copy request to several I/O devices (e.g. both Winchester disks), but has not been able to copy to all of them, or the data amount in the source is less than requested.

11471 LOCAL COPY HAS SUCCEEDED BUT DESTINATION FILE IS FULL

OVFSRP has performed the requested local copy operation, but the destination file became full. This is not an error, but a notice to the user for changing the output file.

11472 LOCAL COPY SERVICE FAILED BECAUSE READING SOURCE FAILED

The local copy service provided by the OVFSRP program block was unsuccessful because the reading source (a file or a buffer) failed.

11473 LOCAL COPY SERVICE FAILED BECAUSE WRITING TO DESTINA-TION FAILED

Page 169: DX Error Messages

DN987378Issue 24-0

169

General Error Messages of System DX error messages

Id:0900d8058077e097

The local copy service provided by the OVFSRP program block was unsuccessful because the writing to the destination (a file or a buffer) failed.

11474 LOCAL COPY SERVICE FAILED

The local copy service provided by the OVFSRP program block has failed for some unknown reason.

11475 REFERENCE NUMBERS ARE NOT SAME IN UPDATING AND ACKNOWLEDGEMENT MESSAGES

The reference numbers in updating and acknowledgement messages are not the same.

11476 ATM CONNECTION MODE MISMATCH ERROR

ATM connections can be either of two modes: unidirectional - data passed in one direction only, and bidirectional - data passed in both directions. In certain situations the requested mode of connection is not possible and results in the generation of this error code. Example: Operator requests a spare connection where the primary connection is unidirectional. This kind of service is only possible with bidirectional connections.

11477 SIGNALLING BETWEEN STM AND NETWORK FAILED

Signalling between the STM and the network has failed.

11478 NUMBER OF TRXS DEFINED IN CONFIGURATION MESSAGE IS INCONSISTENT WITH BTS DATABASE

The number of TRXs defined in the configuration message is not con-sistent with the BTS database.

11479 INVALID PARAMETERS FOR CLNS

The parameters of the CLNS are faulty. Creation or modification is not possible.

11480 UNABLE TO LOCK ACTIVE CLNS

The locking of an active CLNS is prohibited.

11482 OMNFIL HANDLING FAILED

The reading or writing of the OMNFIL file has failed.

11483 READING OF OFLPAR FAILED

The reading of the OFLPAR file has failed.

11484 HANDLING OF OMLFIL FAILED

Reading from or writing to the OMLFIL file has failed.

11485 HANDLING OF OMDFIL FAILED

Reading from or writing to the OMDFIL file has failed.

11486 CLNS MUST BE LOCKED FOR THIS OPERATION

The CLNS must be locked for this operation.

11487 INVALID PARAMETERS FOR LINKAGE

The parameters of the linkage are faulty. Modification or creation of linkage is not possible.

Page 170: DX Error Messages

170 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11488 LINKAGE PARAMETER SET NOT FOUND

The parameter set of the linkage for default values is not found.

11489 ACTIVATION OF ATTRIBUTE MODIFICATION FAILED

The activation of given attributes has failed. The active CLNS uses the values of old attributes.

11490 LINKAGE MUST BE LOCKED FOR THIS OPERATION

The linkage must be locked for this operation.

11491 ATM NODE DOES NOT EXIST

The ATM node does not exist.

11492 ATM NODE ALREADY EXISTS

The ATM node already exists.

11493 TEST HAS STOPPED

The mass traffic test of the call generator is not active.

11494 ANOTHER TEST IS ACTIVE

Another mass traffic test in the call generator is active.

11495 FIRST PARAMETER MESSAGE IS MISSING

The call generator has not received its first parameter message.

11496 CLNS CANNOT BE USED FOR INITIALIZATION

The CLNS cannot be used for the initialization of ODEUPD because it is probably locked.

11497 FLOATING TRX IS ALLOWED ONLY TO BCFS THAT HAVE SECTORS OF ONE TRX

If a floating TRX exists in a BCF, only one normal TRX can be created to each sector. Also, a floating TRX can only be created to a BCF that has sectors of no more than one TRX.

11498 BCF CAN HAVE ONLY ONE FLOATING TRX

A floating TRX can only be created if there is no previous floating TRX in that BCF.

11499 REJECT FROM CONNECTION MANAGER IN LINE PLUG-IN UNIT

Indicates that the connection management program block in a cell relay line plug-in unit has rejected a service request.

11500 UPDATE FAILED TO BOTH WDISKS

Update failed to both disks.

11501 UPDATE FAILED TO I/O UNIT W0

The update failed to I/O unit W0.

11502 UPDATE FAILED TO I/O UNIT W1

The update failed to I/O unit W1.

11503 ADMINISTRATIVE STATES OF TRXS CONTROL CHANNELS MUST BE UNLOCKED

Page 171: DX Error Messages

DN987378Issue 24-0

171

General Error Messages of System DX error messages

Id:0900d8058077e097

The requested operation was rejected due to the administrative state(s) of the TRXs control channel(s) being LOCKED. They must be UNLOCKED.

11504 EXECUTION TIME HAS EXPIRED

The execution time has already been passed.

11505 ILLEGAL DATE

The date is illegal, or the family cannot handle the date.

11506 ILLEGAL TIME

The time is illegal, or the family cannot handle the time.

11507 COMMAND FILE ALREADY EXISTS

On the disk there is already a command file with this name.

11508 COMMAND FILE DOES NOT EXIST

There is no such command file on disk.

11509 ILLEGAL PERIOD

A period cannot be presented in this way.

11510 NO ROOM FOR NEW COMMAND

There is no room for new tasks because CTRCAL is full.

11511 NO ROOM FOR NEW OUTPUT DEVICE DECLARATION

There is no room for new output device declarations, because NAMCAL is full.

11512 NO ROOM FOR NEW USER ID

There is no room for new user IDs because the NAMCAL file is full.

11513 COMMAND OR PARAMETERS NOT FOUND

The command or its parameters is not found.

11514 COFFER DID NOT WAIT FOR NEW COMMAND

The waiting time for a new command has expired.

11515 COMMAND LENGTH ERROR

There is an error in the length of a command.

11516 INVALID TASK GIVEN

The requested task or command is invalid.

11517 BACKGROUND DOWNLOAD IS PREVENTED BY BCF RESET

The BCF software handling system prevents the background download after build attachment, if the BCF reset is going on.

11518 BACKGROUND DOWNLOAD IS PREVENTED BY BCSU OVERLOAD

The BCF software handling system prevents background downloading because of the load rate of a signalling unit.

11519 BCF BUILD TYPE IS UNKNOWN TO BCF BUILD HANDLING SYSTEM

The BCF build handling system does not support this build type.

11520 FILE SIZE NOT CONSISTENT WITH MASTER FILE INFORMATION

Page 172: DX Error Messages

172 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The physical size of an application file does not correlate with master file information.

11521 BTS SITE TYPE AND BCF BUILD TYPE ARE MISMATCHED

The BTS site type and BCF build type are mismatched.

11522 NO RESPONSE FROM BASE STATION

A base station did not respond during time supervision to the task sent.

11523 BASE STATION TRANSMITTER START-UP FAILURE AFTER BASE STATION ALARM RESET

The starting-up of a base station transmitter has failed after a base station alarm reset.

11524 TIME OUT ON WAITING FOR INQUIRY ACK

A time out has occured when ASWMAN was waiting for an acknowl-edgement message from the SWCOP unit.

11525 WRITE BUFFER GIVEN TO OCEAPI TOO SMALL

The size of the write buffer given to the OCEAPI library program is too small to save the current CMIS primitive.

11526 PARAMETER GIVEN TO OCEAPI HAS AN ILLEGAL VALUE

At least one parameter given to the OCEAPI library function has an illegal value.

11527 READ ERROR IN OCEAPI LIBRARY PROGRAM

Error in reading CMIS primitive from message or memory buffer in OCEAPI library program.

11528 BTS NUMBER POINTS OUT OF FILE

The BTS number is greater than the number of available records in the parameter file of the HO/PC Algorithm.

11529 CONFLICTING ADJACENT CELL DATA BETWEEN HO/PC ALGO-RITHM AND BSC DATABASE

An adjacent cell has been created into the BSC database, but the HO/PC Algorithm is not aware of the adjacent cell.

11530 TOO MANY ADJACENT CELLS, OR BCCH ALLOCATION LISTS RECEIVED FROM BSC DATABASE

The HO/PC algorithm receives more adjacent cells from the BSC database than expected. Or the HO/PC algorithm receives more BCCH allocation lists from the BSC database than expected.

11531 PARAMETER FILES OF HO/PC ALGORITHM ARE CORRUPTED

The parameter files of the HO/PC algorithm which include information about the adjacent cells are corrupted.

11532 BTS WITH RF HOPPING CAN HAVE MAX 2 TRXS

There was an attempt either to create more than 2 TRXs to a BTS that uses RF hopping, or to change a BTS that has more than 2 TRXs to use RF hopping.

11533 CONNECTION FAILURE IN SWICOP OR NCSPRO

Page 173: DX Error Messages

DN987378Issue 24-0

173

General Error Messages of System DX error messages

Id:0900d8058077e097

A connection attempt by the SWICOP or NCSPRO program block has failed.

11534 ANCU COMMUNICATION FAILURE

A communication failure has occurred between ANCU and OMU, or between two program blocks in ANCU.

11535 CONNECTING CIRCUIT TO TEST POINT FAILED

The set-up of a test connection has failed.

11536 RELEASING CIRCUIT FROM TEST POINT FAILED

The resetting of the test connection has failed.

11537 TEST LOOP STILL EXISTS

The test loop is still connected.

11538 TEST FRAMES RETURNED CHANGED

The test frames have returned in a changed condition.

11539 NO TEST FRAMES RETURNED

The test frames did not return.

11540 BASE STATION SELF TEST FAILED

The base station self test on the given base station circuit has failed.

11541 NO FREE TSL LEFT FOR TEST CONNECTION

There is no free TSL left for connecting the given circuit to a test point. The set-up of the test connection has failed.

11542 TEST DEVICE FOR TEST CONNECTION NOT FOUND

There is no test device for connecting the given circuit to a test point. The set-up of the test connection has failed.

11543 TEST CONNECTION MISSING

The circuit is not connected to a test point. The disconnection of the SPU-U has failed.

11544 SPU-U DISCONNECTED

The Signal Processing Unit SPU-U of the circuit is still disconnected. The releasing of the circuit from the test point has failed.

11545 COMMAND CALENDAR TASK IS BLOCKED

The calendar task is blocked either by the user with CDCMML or by the command calendar.

11546 REMOTE MMI OPTION IS NOT IN USE IN BSC

The remote MMI option is not in use in the BSC.

11547 LOCAL COPY PARTLY SUCCESSFUL, DESTINATION FILE FULL

The local copy service has been partly successful and the destination file has become full.

11548 AOMPRB OR BTS SITE HAS NOT ANSWERED BCF RESET OR CONFIGURATION REQUEST

GUPDAT has requested AOMPRB to reset the BCF, or to configurate the BTS site via the BTS O&M link. BTS or AOMPRB have not responded to the requests within the time limit.

Page 174: DX Error Messages

174 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11549 NO FREE INCOMING VIRTUAL PATH

No free incoming virtual path.

11550 NO FREE OUTGOING VIRTUAL PATH

No free outgoing virtual path.

11551 TRX IS GIVEN ON OTHER LIST

The TRX ID list contains a TRX which is already given on another list.

11552 CPE CALL QUEUE FULL

The queue of calls, in the calling channel, to a CPE is full.

11553 NSAP TYPE IS DIFFERENT FROM NETWORK ADDRESS TYPE

The NSAP type is different from the network address type.

11554 NSAP IS ALREADY ATTACHED TO NETWORK ADDRESS

There has been an attempt to attach an NSAP to a network address, but it is already attached to the network address.

11555 NSAP IS NOT ATTACHED TO NETWORK ADDRESS

There has been an attept to detach an NSAP from a network address, but the NSAP is not attached to the network address.

11556 BACKUP CLNS NOT FOUND

No CLNS with the activity state BACKUP exists in the OEDATA data-base.

11557 ROUTE EXISTS FOR CONNECTION

A route was found to exist for the broadband connection.

11558 CONNECTION EXISTS FOR BROADBAND ACCESS

A connection exists for the broadband access.

11559 CONNECTION DOES NOT EXIST FOR ACCESS

The connection does not exist for the Broadband Access.

11560 NO FREE CONNECTION INDEX AVAILABLE

Occurs when an attempt is made to reserve a connection index from the FBBASE for an access in which all the connection indexes are currently in use.

11561 ATM VIRTUAL PATH EXISTS

Indicates that a certain ATM virtual path already exists.

11562 ATM VIRTUAL PATH DOES NOT EXIST

Indicates that a certain ATM virtual path does not exist.

11563 REQUEST FOR STATIC STATE INFORMATION OF RADIO NETWORK FAILED

Configuring the location areas has failed.

11564 RNEUPD HAS NO RESOURCES FOR REQUESTED TASK

RNEUPD is busy. It has not finished its previous task.

11565 MAC USER LIST IS FULL

Page 175: DX Error Messages

DN987378Issue 24-0

175

General Error Messages of System DX error messages

Id:0900d8058077e097

The user list of the Ethernet MAC driver program is full, so it is not possible to add any more users to the Ethernet plug-in unit (COCEN) in question.

11566 SERVICE ACCESS POINT LIST IS FULL

The service access point list of the Ethernet MAC driver program is full, so it is not possible to bind any more IEEE 802.2 SAPs or Ethernet V2.0 protocol types to the Ethernet plug-in unit (COCEN) in question.

11567 SERVICE ACCESS POINT IS ALREADY IN USE

Some MAC user has already reserved the SAP in question. It is not allowed for two programs to use the same Ethernet plug-in unit (COCEN) and have identical IEEE 802.2 SAPs or Ethernet V2.0 protocol types, because it must be possible to determine unequivocally the receiving program when a packet is received from the Ethernet. This is done by the Ethernet MAC driver program, on the basis of the SAP field of the packet.

11568 SERVICE ACCESS POINT IS NOT FOUND

The service access point is not on the list of the Ethernet MAC driver program, so it is not possible to unbind that IEEE 802.2 SAP or Ethernet V2.0 protocol type from a MAC user.

11569 MAC USER IS NOT FOUND

The user is not on the list of the Ethernet MAC driver program, so it is not possible to bind or unbind an SAP from that user, or to delete that user.

11570 LINKAGE TYPE MISMATCH

The type issued in the modify command does not match with the type (X.25/broadcast) of the existing linkage.

11572 MAXIMUM NUMBER OF TEST GROUPS ALREADY CREATED

The maximum number of test groups is ten. This error code is received when the maximum is exceeded.

11573 NO SUCH TEST GROUP

The routine test group was not found.

11574 TEST GROUP ALREADY CREATED

The routine test group has been defined. This error code is received when an attempt has been made to define a routine test group with an identifier that is in use.

11575 TEST GROUP NOT IN PROPER STATE

The routine test group was not in the proper state.

11576 ATM TRUNK ACCESS ALREADY EXISTS

The ATM trunk access already exists.

11577 A RECEIVING CHANNEL FOR TESTING IS ALREADY ACTIVE

There has been an attempt to open a second receiving channel for testing, although only one receiving channel is allowed to be in testing at a time.

Page 176: DX Error Messages

176 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11578 ERRONEOUS PARAMETERS OF MODEM SIGNALLING IN CHANNEL OPENING

The parameters of modem signalling in the channel opening message are not correct.

11579 SENDING WAS NOT SUCCESSFUL

The sending of data was not completed without errors in the MFST plug-in unit.

11580 OTHER TEST CONNECTION OR TEST LOOP ON

There is another test connection or test loop on the given base station circuit.

11581 CIRCUIT GROUP RNTEST IN WRONG STATE

The channel cannot be connected to the test terminal because the circuit group RNTEST is not in a working state.

11583 OPERATION REJECTED DUE TO ONGOING TEST

The channel is in a test.

11584 NO FREE MESSAGE INDEX ERROR

Messages between the Cell Relay Subscriber Unit and the Cell Relay Line Interface plug-in units are assigned a message index. In the event that all the message indexes are in use and it is impossible to reserve a new one, this error code is generated.

11585 NO TRAFFIC ON HOME BASE STATION OF SUBSCRIBER

The home base station of a WLL subscriber (i.e. the base station in which the subscriber is located) is in a state in which it is not capable of transferring terminating calls.

11586 BROADBAND SUBSCRIBER UNIT DOES NOT EXIST

The specified broadband subscriber unit was found not to exist.

11587 BROADBAND SUBSCRIBER UNIT EXISTS

The specified broadband subscriber unit was found to exist.

11588 HAND CREATION DID NOT SUCCEED

A master process has tried to create a hand process, but the creation was unsuccessful.

11589 BTS ALARMS RECOVERY SEND TIMES LIMIT EXCEEDED

BTLARM has tried to send a BTS alarm indication to GUPDAT 60 times, but GUPDAT has not been able to perform the task, and the recovery has failed.

11590 D-CHANNEL IS BUSY

The subscriber line is used for calls, and disconnection has not been successful. Please use the forced test type, if you want to test this line.

11591 FIRST DISTINCTIVE RINGING NUMBER

The first distinctive ringing number.

11592 SECOND DISTINCTIVE RINGING NUMBER

The second distinctive ringing number.

Page 177: DX Error Messages

DN987378Issue 24-0

177

General Error Messages of System DX error messages

Id:0900d8058077e097

11593 THIRD DISTINCTIVE RINGING NUMBER

The third distinctive ringing number.

11594 FOURTH DISTINCTIVE RINGING NUMBER

The fourth distinctive ringing number.

11595 FIRST PARALLEL DISTINCTIVE RINGING NUMBER

The first parallel distinctive ringing number.

11596 SECOND PARALLEL DISTINCTIVE RINGING NUMBER

The second parallel distinctive ringing number.

11597 THIRD PARALLEL DISTINCTIVE RINGING NUMBER

The third parallel distinctive ringing number.

11598 FOURTH PARALLEL DISTINCTIVE RINGING NUMBER

The fourth parallel distinctive ringing number.

11599 FIRST RSU DISTINCTIVE RINGING NUMBER

The first RSU distinctive ringing number.

11600 SECOND RSU DISTINCTIVE RINGING NUMBER

The second RSU distinctive ringing number.

11601 THIRD RSU DISTINCTIVE RINGING NUMBER

The third RSU distinctive ringing number.

11602 FOURTH RSU DISTINCTIVE RINGING NUMBER

The fourth RSU distinctive ringing number.

11603 FIRST PARALLEL RSU DISTINCTIVE RINGING NUMBER

The first parallel RSU distinctive ringing number.

11604 SECOND PARALLEL RSU DISTINCTIVE RINGING NUMBER

The second parallel RSU distinctive ringing number.

11605 THIRD PARALLEL RSU DISTINCTIVE RINGING NUMBER

The third parallel RSU distinctive ringing number.

11606 FOURTH PARALLEL RSU DISTINCTIVE RINGING NUMBER

The fourth parallel RSU distinctive ringing number.

11607 RSU DOUBLE TELEPHONE NUMBER

RSU double subscriber number.

11608 PARALLEL RSU DOUBLE TELEPHONE NUMBER

Parallel RSU double subscriber number.

11609 DISTINCTIVE RINGING FACILITY IS ALREADY DEFINED FOR SUB-SCRIBER

Distinctive ringing has already been defined for the subscriber.

11610 OPENING MML SESSION FOR CALENDAR FAILED

Opening an MML session for the command calendar has failed. MMIMAN does not allow a session to be opened, or it does not respond to an opening request.

11611 NSAP REFERS TO PHYSICAL CHANNEL GROUP TO BE DELETED

Page 178: DX Error Messages

178 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The delete operation cannot be performed because there is at least one NSAP address reference to the X.25 physical channel group to be deleted.

11612 UNKNOWN COMMAND FROM I/O MANAGER RECEIVED

The Command Calendar Program Block (COKALE) has received an unknown command from the I/O Manager Program Block (IOMANA).

11613 ILLEGAL HANDLE RECEIVED IN MESSAGE

A program block cannot open a received buffer because of an illegal handle in the buffer.

11614 DIALOG DID NOT ASK CALENDAR COMMAND

DIALOG did not ask the MML command belonging to the task whose execution had been started, so the task was not completed succesfully.

11615 OCEAPI SUPPORT FUNCTION FAILED

The OCEAPI support function has failed.

11616 DISTINCTIVE RINGING NUMBER ALREADY EXISTS

The distinctive ringing number already exists.

11617 DISTINCTIVE RINGING NUMBER DOES NOT EXIST

The distinctive ringing number does not exist.

11618 BCF HW DATABASE FILE TOO BIG

The size of the BCF HW database file is more than the allowed maximum.

11619 VIRTUAL ANSWER DEVICE FACILITY IS NOT IN USE

The virtual answer device facility is not in use.

11620 MESSAGE WAITING ACTIVATION NUMBER MISSING

The activation number for the message waiting facility is missing.

11621 MESSAGE WAITING PASSIVATE NUMBER IS MISSING

The passivation number for the message waiting facility is missing.

11622 MESSAGE WAITING NUMBERS ARE MISSING

The activation and passivation numbers for the message waiting facility are missing.

11623 APPLICATION TYPE IS DIFFERENT FROM NETWORK ADDRESS TYPE

The application type is different from the network address type.

11624 ANALOGUE VOICE MAIL SUBSCRIBER

Analogue voice mail subscriber.

11625 LOCAL USER HAS OPENED SERVICE TERMINAL SESSION

A local user has opened a service terminal session. The remote session is prohibited during local operations.

11626 INVALID APPLICATION PARAMETERS

The contents of the application parameters are invalid, rendering them impossible to handle.

Page 179: DX Error Messages

DN987378Issue 24-0

179

General Error Messages of System DX error messages

Id:0900d8058077e097

11627 PARAMETERS CANNOT BE CHANGED

The modification of given parameters is not allowed.

11628 INVALID X.25 ADDRESS INFORMATION

The given X.25 address (SVC/PVC) information is invalid.

11629 TERMINAL HAS NO SVC CHANNELS

No SVC channels are configured to the X.25 data terminal.

11630 TERMINAL HAS NO PVC CHANNELS

No PVC channels are configured to the X.25 data terminal.

11631 INVALID VALUE FOR PVC CHANNEL

The given value may not be assigned to the PVC channel.

11633 TERMINAL HAS NO AVAILABLE PVC CHANNELS

The X.25 data terminal has no available PVC channels, all are reserved for other users.

11634 TERMINAL HAS NO AVAILABLE SVC CHANNELS

The X.25 data terminal has no available SVC channels, all are reserved for other users.

11635 WRONG TERMINAL TYPE FOR GIVEN LINKAGE

The terminal type differs from the type of linkage. The linkage cannot be activated to a data terminal of that type.

11636 TERMINAL ALREADY HAS ACTIVE LINKAGE

There is already an active linkage in the data terminal, which prohibits activation of the given linkage. A terminal may have several linkages, but they must not have identical parameters.

11637 ROLE (ES/IS) MISMATCH

The roles of the linkage and CLNS do not match.

11638 NO REASON FOR FAILURE OF OPERATION

CLNS returned no reason for the failure of the operation.

11639 ACCESS DENIED BY CLNS

CLNS denied execution of the operation.

11640 INVALID ATTRIBUTE VALUE

The given attribute value is invalid.

11641 ATTRIBUTE VALUE IS MISSING

The required attribute value is not included in the management opera-tion.

11642 INVALID ATTRIBUTE IDENTIFIER

The given attribute identifier is an invalid one.

11643 INVALID OBJECT CLASS IDENTIFIER

The object class identifier is invalid.

11644 PROCESSING FAILURE

An operation on the CLNS was terminated by a processing failure.

Page 180: DX Error Messages

180 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11645 CLNS RETURNED UNKNOWN ERROR CODE

The CLNS returned an unknown error code for a failure.

11646 INVALID RANGE OF ATTRIBUTE VALUES

The range of attribute values is invalid.

11647 INVALID INSTANCE IDENTIFIER

The instance identifier of an object is invalid.

11648 NIGHT TRANSFER NUMBER

There has been an (illegal) attempt to remove a service number which is also a night transfer number.

11649 OVERFLOW NUMBER

There has been an (illegal) attempt to remove a service number which is also an overflow number.

11650 WEEKDAY RESTRICTION DOES NOT ALLOW EXECUTION

The date and weekday combination will not allow the execution of the task.

11651 BTS ALARM RECOVERY FAILURE DUE TO SYSTEM RESTART

The system has been restarted by the ZUSS command, and an ongoing BTS alarm recovery has failed due to the restart.

11652 TERMINAL IS DISABLED

The terminal of a linkage is in a disabled state, which prevents the acti-vation of the linkage.

11653 ACTIVITY STATE OF CLNS IS BACKUP

The locking of a CLNS whose activity state is backup (BU) is prohibited.

11654 ABIS O&M MESSAGE BTS_PWR_SUPPLY_CONTROL FAILED (TIMEOUT OR NEGATIVE ACKNOWLEDGEMENT)

BSC failed to control the TRX power supplies of a BTS site. The scenario was interrupted.

11655 SYNTAX ERROR IN COMMAND FILE

There is a syntax error in the command file. Check the file.

11656 COMMAND NOT FOUND IN COMMAND FILE

There are no more commands in a command calendar command file.

11657 BROADBAND LINE INTERFACE ALREADY ASSIGNED

The given broadband line interface is already assigned.

11658 LAC/CIS OF CELL REFERRED IN ADJACENT CELL OBJECT AND TARGET CELL OBJECT ARE DIFFERENT

The LAC/CIs of the cell referred to in the adjacent cell object and of the target cell object are different in the BSC radio network configuration database. The conflict was caused when updating the LAC and/or CI parameters of the cell with the ZEQE command. These modifications are not updated to the adjacent cell specifications. To correct the adjacent cell specifications the user has to delete the adjacent cell and then create it again.

Page 181: DX Error Messages

DN987378Issue 24-0

181

General Error Messages of System DX error messages

Id:0900d8058077e097

11659 GIVEN CALENDAR TASK NOT FOUND

The given calendar task has not been found in the calendar. Check the task identifier.

11660 DISTINCTIVE RINGING NUMBER EXISTS

There must exist no distinctive ringing numbers for a subscriber when deleting the subscriber or the RSU subscriber neither is it acceptable to remove distinctive ringing facility if there are any distinctive ringing numbers left.

11661 RECORD NUMBER OUT OF CALENDAR FILE LIMITS

There is no such record in the CTRCAL disk file.

11662 ATM STATISTICS STOPPED

The operation failed because ATM statistics has been stopped.

11663 NOT ENOUGH TIME LEFT TO DESIRED EXECUTION TIME

The execution time must be set at least five minutes from the present time.

11664 ATM USER DOES NOT EXIST

The ATM user does not exist.

11665 SERVICE SET RECORD EXISTS ALREADY

A service set record with the given ID string exists already in the trigger file.

11666 SERVICE SET RECORD DOES NOT EXIST

A service set record with the given ID string does not exist in the trigger file.

11667 TRIGGER RECORD IS REFERRED TO

A trigger record is referred to from a service set. The record cannot be removed before the references are removed.

11668 SERVICE SET RECORD IS REFERRED TO

A service set record is referred to. The record cannot be removed before the references are removed.

11669 SERVICE SET NAME DOES NOT EXIST

A service set record with the given name does not exist in the trigger file.

11670 SERVICE SET DOES NOT CONTAIN ANY TRIGGERS

The service set record does not contain any references to triggers.

11671 CUG HAS NO MEMBERS

The closed user group (CUG) has no members.

11672 CLOSED USER GROUP DOES NOT EXIST

The closed user group (CUG) does not exist.

11673 LINKAGE IS NOT ACTIVE

The linkage is not active at the moment. The reason may be a fault in the data terminal, or in the connectionless network service.

11674 VPI NOT FOUND

Page 182: DX Error Messages

182 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The VPI is not found.

11675 VCI NOT FOUND

The VCI is not found.

11676 LOGICAL INCONSISTENCY IN DATABASE

The database is logically inconsistent.

11677 OBJECT IS PROTECTION UNIT

The requested operation is prohibited because the object is a protection unit.

11678 NO SUCH CROSS CONNECTION INSTANCE

The given cross connection instance does not exist.

11679 NO SUCH MULTIPOINT CROSS CONNECTION INSTANCE

The given multipoint cross connection instance does not exist.

11680 CLOSED USER GROUP ALREADY EXISTS

A closed user group with the given CUG interwork code already exists.

11681 CUG MEMBER WITH GIVEN INDEX ALREADY EXISTS

A closed user group member with the given CUG index already exists.

11682 ARF SUBSCRIBER NOT FOUND

The given ARF subscriber was not found.

11683 RSU NOT FOUND

The RSU data for the given ARF subscriber was not found from the Subscriber Facility Database.

11684 DEFAULT CLOSED USER GROUP ALREADY EXISTS

The subscriber already has a default closed user group.

11685 SUBSCRIBER HAS NO CUG INDEX

There is no relation between the given subscriber and a CUG member, or there is a relation, but the given CUG index is incorrect.

11686 SUBSCRIBER HAS NO DEFAULT CUG

The subscriber does not have a default closed user group.

11687 FIRST MFC DIGIT NOT RECEIVED WITHIN TIME LIMIT

The MFC signalling control program has found that the first MFC digit was not received within the time limit.

11688 SPACE BETWEEN MFC DIGITS IS TOO LONG

The MFC signalling control program has found that there was too long a pause between two MFC digits.

11689 DIAL TONE NOT IDENTIFIED WITHIN TIME LIMIT

The MFC signalling control program has found that the dial tone was not recognised within the time limit.

11690 IMEI COULD NOT BE OBTAINED FROM MOBILE

An inquiry to the A-interface for the IMEI of a mobile failed because the mobile did not respond to the A-interface inquiry.

Page 183: DX Error Messages

DN987378Issue 24-0

183

General Error Messages of System DX error messages

Id:0900d8058077e097

11691 A-INTERFACE HAND PROCESS FOR THIS CONNECTION DOES NOT EXIST

The Transaction Management Program Block identified an A-Interface hand process that controls the connection of a given subscriber, but the identified hand process does not exist.

11692 ERROR IN SETTING CONNECTION PROTECTION STATE

This error code is used when the state change of a connection protec-tion fails.

11693 NO FREE PILOT CHANNELS LEFT

All pilot channels are reserved, no free ones are left.

11694 FREEZING OF CRSU COUNTERS IN PROGRESS

The freezing of the counters of the CRSU unit is in progress.

11695 SOME PARAMETER IS PLUG-IN UNIT SPECIFIC. ALL SUBSC LINES OF PLUG-IN UNIT MUST BE CHANGED

Some programmable parameter of a subcriber line is plug-in unit spesific. All subscriber lines of the plug-in unit in question must be changed at the same time.

11696 NO ACTIVE CLNS FOUND

None of the CLNS objects in the OSI database were active.

11697 DATA TERMINAL IS LOCKED

The administrative state of a physical channel of the data terminal is LOCKED, which prohibits the use of the terminal.

11698 DISK COPYING ALREADY STARTED

The ASKDIS program block sends this information in a message to the ASRPRO program block, if disk copying has already been started when ASKDIS receives a start disk copying message.

11699 DATA COLLECTION AFTER CRSU CHANGE IS IN PROGRESS

Data collection from the changed CRSU unit is in progress.

11700 TOO MANY ARFCN VALUES (R1024)

The creation of range 1024 fails because there are too many ARFCN values.

11701 ATM VP ADDRESS INVALID

The supplied ATM Virtual Path address is invalid.

11702 ATM VC ADDRESS INVALID

The supplied ATM Virtual Channel address is invalid.

11703 BROADBAND INTERFACE IS UNI

The broadband interface is a user-network interface.

11704 BROADBAND INTERFACE IS NNI

The broadband interface is a network node interface.

11705 BROADBAND ACCESS RATE ERROR

Error in supplied broadband access rate.

11706 FR LINK INTEGRITY TYPE UNKNOWN

Page 184: DX Error Messages

184 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Frame Relay Link Integrity Type unknown.

11707 DATABASE SYSTEM IS OVERLOADED

The transactions queue is full in the database system. New transactions will be cancelled with this error code.

11709 ATM MEASUREMENT NAME ALREADY IN USE

The creation of an ATM measurement failed because the measurement name is already in use.

11710 ATM MEASUREMENT OBJECT DOES NOT EXIST

The creation of an ATM measurement failed because some of the objects to be measured do not exist.

11711 MEASUREMENT OBJECT IS NOT DESIRED TYPE

The creation of an ATM measurement failed because the measurement object is not of the desired type.

11712 NAME TABLE IS FULL

The program block NASEVA is not capable of adding the new service, because the name table is full.

11713 SERVICE IS DEFINED UNREPLACEABLE

The program block NASEVA is not capable of replacing the given service, because the service has been defined unreplaceable.

11714 SERVICE IS NOT FOUND IN NAME TABLES

The program block NASEVA is not capable of finding the given service in the name tables.

11715 MAXIMUM NUMBER OF ATM MEASUREMENTS ALREADY EXISTS

The creation of an ATM measurement failed because the maximum number of the desired type of measurement already exists.

11716 GENERAL SERVICE CANNOT BE UPDATED TO LOCAL SERVICE

The program block NASEVA is not capable of updating a general service to a local service.

11717 ATM MEASUREMENT DOES NOT EXIST

The function fails because the identified ATM measurement does not exist.

11718 ATM MEASUREMENT ACTIVE

The function fails because the ATM measurement is active.

11719 UNKNOWN DISCONNECT REASON

The reason for the release of the OSI transport connection is not known.

11720 TRANSPORT SERVICE USER TRANSIENTLY UNAVAILABLE

The called transport service user is not available, but the condition is transient.

11721 TRANSPORT SERVICE USER UNAVAILABLE PERMANENTLY

The called transport service user is not available, and the condition per-sists.

11722 TRANSPORT ADDRESS UNKNOWN

Page 185: DX Error Messages

DN987378Issue 24-0

185

General Error Messages of System DX error messages

Id:0900d8058077e097

The called transport address is unknown.

11723 NORMAL DISCONNECT INVOKED BY TRANSPORT SERVICE USER

A normal disconnection initiated by a remote Transport Service user.

11724 REMOTE TRANSPORT ENTITY CONGESTED

The remote transport entity suffered from congestion at the time of the connect request.

11725 CONNECTION NEGOTIATION FAILED

A connection negotiation has failed, i.e. the proposed Transport protocol classes are not supported. This is a persistent condition.

11726 DUPLICATE SOURCE TRANSPORT REFERENCE

A duplicate source transport reference was detected for the same pair of NSAPs.

11727 MISMATCHED TRANSPORT REFERENCES

The remote transport entity specified an unknown transport reference.

11728 TRANSPORT PROTOCOL ERROR

A transport protocol error has occurred.

11729 LENGTH INDICATOR ERROR

The header or parameter length of a Transport Protocol Data Unit was invalid.

11730 TRANSPORT SERVICE MISBEHAVIOUR

The remote transport service provider (or user) misbehaved by not answering a connection request within the specified time limit.

11731 TRANSPORT REFERENCE OVERFLOW

A transport reference overflow has occurred.

11732 CONNECTION REFUSED ON NETWORK CONNECTION

A connection request has been refused on this network connection.

11733 QOS BELOW MINIMUM

The Quality of Service was below the minimum accepted value.

11734 ATM MEASUREMENT NOT ACTIVE

The function fails because the identified ATM measurement is not active.

11735 MAXIMUM NUMBER OF ATM MEASUREMENTS ALREADY ACTIVE

The activation of an ATM measurement failed because the maximum number of measurements is already active.

11736 ANOTHER ACTIVE MEASUREMENT IS ALREADY MEASURING OBJECT

The activation of an ATM measurement failed because the object is already being measured by another active measurement.

11737 ATM MEASUREMENT STOPPED BY OPERATOR

An ATM measurement is interrupted because the operator has stopped it.

Page 186: DX Error Messages

186 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11738 ATM MEASUREMENT IS DELETED

The ATM measurement is deleted because its objects were deleted.

11739 ATM MEASUREMENT DATA INVALID

ATM measurement result data is not valid.

11740 CANNOT SET/DELETE BASIC JUMPER GROUP

The routine cannot set or delete a basic jumper group. The routine can handle only jumper groups created by the user.

11741 WARMING NOT POSSIBLE WITH FAMILY ATTRIBUTE COMBINA-TION USED

Warming is not possible with the family attribute combination used.

11742 ABIS O&M MESSAGE BTS_OUTPUT_CONTROL FAILED (TIME-OUT OR NEGATIVE ACKNOWLEDGEMENT)

BSC failed to control the binary outputs of a BTS site.

11743 ABIS O&M MESSAGE BTS_CHA_ADM_STATE FAILED (TIME-OUT OR NEGATIVE ACKNOWLEDGEMENT)

BSC failed to change the administrative state of a BTS site.

11744 ABIS O&M MESSAGE BTS_RESET_REQ FAILED (TIME-OUT OR NEGATIVE ACKNOWLEDGEMENT)

BSC failed to request reset (for BCF/BTS/TRX) to a BTS site.

11745 WRONG TYPE OF ANALYSIS TREE

The analysis tree is in other use, it can e.g. be reserved for restriction analyses, and so other types of analysis are not allowed in this tree, or vice versa.

11746 INVALID APPLICATION CONTEXT

The Application Context is illegal, or is not supported.

11747 SYSTEM INFORMATION MESSAGES HAVE NOT BEEN SENT

ABIPRB has not received system information acknowledgement messages from BTS.

11748 SERVICE HAS DIFFERENT PARAMETERS

The given service already exists, but with different parameters.

11749 FREEZING OF ATM STATISTICS DISTRIBUTED PART METERS FAILED

The freezing of the ATM statistics meters of the distributed part failed.

11750 ATM STATISTICS METERS COLLECTION FAILED

The collecting of the ATM statistics meters from the distributed to the centralised part failed.

11751 NO SYSTEM INFORMATION ACK MESSAGES RECEIVED FROM LAYER 2

ABIPRB has not received system information acknowledgement messages from layer 2.

11752 SERVICE BELONGS TO GROUP OF SERVICES

Page 187: DX Error Messages

DN987378Issue 24-0

187

General Error Messages of System DX error messages

Id:0900d8058077e097

The service was found in the name table and it belongs to a group of services. The service cannot be updated to an individual service.

11753 SAME MEASUREMENT OBJECT IS GIVEN TWICE

The creation of a virtual traffic measurement has failed because the same measurement object was given twice.

11754 NO RESPONCE FROM ATDSTA

The ATDSTA program block does not respond.

11755 NO ACCEPTABLE CLNS

There is no CLNS object which could be accepted by a user. Accep-tance of a CLNS requires that its operational state is ACTIVE, its admin-istrative state is UNLOCKED, and its activity state is NEW.

11756 INTEGRITY KEY ERROR

The integrity key element being used is incorrect. Either the integrity of the key element is incorrect, or the key element is not found.

11757 INTEGRITY ERROR

The integrity of the data being handled is incorrect.

11758 CONSISTENCY ERROR

The consistency of the data being handled is incorrect. The data differs between different storages.

11759 ENCRYPTION KEY ERROR

The encryption key element being used is incorrect. Either the integrity of the key element is incorrect, or the key element is not found.

11760 INVALID CRYPTOGRAPHIC KEY TYPE

The type of the cryptographic key used in an operation is invalid.

11761 INVALID DATA OBJECT IDENTIFIER

The identifier of the data object being handled is invalid.

11762 CRYPTOGRAPHIC KEY ACTIVE

The cryptographic key being handled is active.

11763 CRYPTOGRAPHIC KEY ALREADY EXISTS

The cryptographic key already exists.

11764 CRYPTOGRAPHIC KEY NOT FOUND

The cryptographic key being used is not found.

11765 CRYPTOGRAPHIC KEY NOT FOUND IN DATABASE

The cryptographic key being used is not found in the Cryptographic Key Database.

11766 CRYPTOGRAPHIC KEY NOT FOUND IN PLUG-IN UNIT

The cryptographic key is not found in the key table of a plug-in unit.

11767 CRYPTOGRAPHIC KEY TABLE FULL IN PLUG-IN UNIT

The cryptographic key table is full in a plug-in unit.

11768 CRYPTOGRAPHIC KEY USED IN DATABASE

The cryptographic key being handled is used in a database.

Page 188: DX Error Messages

188 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11769 CRYPTOGRAPHIC KEY USED IN PLUG-IN UNIT

The cryptographic key being handled is used in a plug-in unit.

11770 NO ACTIVE CRYPTOGRAPHIC KEY FOUND

No active cryptographic key is found for a key type.

11771 SEVERAL ACTIVE CRYPTOGRAPHIC KEYS FOUND

Several active cryptographic keys are found for a key type.

11772 PHYSICAL PROTECTION FAILURE

The physical protection of a plug-in unit is faulty.

11773 COMMUNICATION ERROR WITH PLUG-IN UNIT

An error in the communication with a plug-in unit has occurred.

11774 ILLICIT USE OF CRYPTOGRAPHIC KEY

An illicit attempt to use a cryptographic key has been detected.

11775 NO BCF IN MAINTENANCE MODE

There is no BCF in maintenance mode.

11776 CONFIGURATION FAILURE

Link information has not been received from the ABIPRB program block.

11777 HASH TABLE IS FULL

There is no room for further elements in the hash table.

11778 NO ELEMENT WITH GIVEN KEY VALUE EXISTS

There is no element with the given key value in the given hash table.

11779 THERE IS ALREADY AN ELEMENT WITH THE GIVEN KEY VALUE IN THE HASH TABLE

The hash table has already an element with the given key value. This error occurs only if the table has been specified to have unique keys.

11780 PCM ALREADY IN USE

The PCM is already in use.

11781 DUPLICATE PCM

Duplicate PCM number.

11782 USER PART OF PCM NOT V5

The user part of the given PCM is not V5.

11783 VXADMI BUSY

The program block VXADMI is not capable of receiving new tasks. Try again later.

11784 V5 INTERFACE ALREADY EXISTS

The V5 interface already exists.

11785 V5 INTERFACE DOES NOT EXIST

The V5 interface does not exist.

11786 VXADMI COMMUNICATION ERROR

Page 189: DX Error Messages

DN987378Issue 24-0

189

General Error Messages of System DX error messages

Id:0900d8058077e097

A communication error between VXADMI and some other program block.

11787 CLNS HAS ALREADY MAXIMUM NUMBER OF MANUAL AREA ADDRESSES

A CLNS object already has the maximum number of manual area addresses, so adding a new one is not possible.

11788 CLNS HAS ALREADY MINIMUM NUMBER OF MANUAL AREA ADDRESSES

A CLNS object already has the minimum number of manual area addresses, so removing a manual area address is not possible.

11789 BCF IS NOT IN MAINTENANCE MODE

The BCF is not in maintenance mode.

11790 INCORRECT INTERFACE TYPE

The type of interface is unknown, or it does not fit in the situation.

11791 NO RESPONSE FROM CELL RELAY LINE INTERFACE

This error code indicates that there is no response from a line plug-in unit (e.g. FRA2M) to a request message within the designated time limit.

11792 FTAM FILE ATTRIBUTE CANNOT BE READ

A FTAM file attribute cannot be read.

11793 UPDATING FROM LOCAL TO GLOBAL SERVICE CAUSES CONFLICT

A local service was not updated to a global service, because a global service with the same name already existed.

11794 FTAM NO REASON

No reason. This error is a general FTAM diagnostics message, defined in ISO 8571-3.

11795 FTAM RESPONDER ERROR

FTAM responder error (unspecific). This error is a general FTAM diag-nostics notice, defined in ISO 8571-3.

11796 FTAM INITIATOR ERROR

FTAM initiator error (unspecific). This error is a general FTAM diagnos-tics notice, defined in ISO 8571-3.

11797 TEMPORARY INSUFFICIENCY OF FTAM RESOURCES

A temporary insufficiency of resources. This error is a general FTAM diagnostics notice, defined in ISO 8571-3.

11798 FTAM ACCESS REQUEST VIOLATES VFS SECURITY

A FTAM access request violates the security of the virtual file store. This error is a general FTAM diagnostics notice, defined in ISO 8571-3.

11800 FTAM RESPONDER TIMEOUT

The timeout expired, because the FTAM responder did not answer. This error is a protocol and support service related diagnostics notice, defined in ISO 8571-3.

Page 190: DX Error Messages

190 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11801 FTAM INITIATOR IDENTITY UNACCEPTABLE

The FTAM initiator identity is unacceptable. This error is an association-related diagnostics notice, defined in ISO 8571-3.

11802 FTAM FILE NAME NOT FOUND

A FTAM file name is not found. This error is a selection-related diagnos-tics notice, defined in ISO 8571-3.

11803 FTAM INITIAL ATTRIBUTES NOT POSSIBLE

FTAM initial attributes are not possible. This error is a selection-related diagnostics notice, defined in ISO 8571-3.

11804 FTAM FILE ALREADY EXISTS

The file already exists. This error is a selection-related diagnostics notice, defined in ISO 8571-3.

11805 FTAM FILE CANNOT BE DELETED

The file cannot be deleted. This error is a selection-related diagnostics notice, defined in ISO 8571-3.

11806 FTAM CONCURRENCY CONTROL NOT POSSIBLE

The FTAM concurrency control is not possible. This error is a selection-related diagnostics notice, defined in ISO 8571-3.

11807 FTAM FILE IS BUSY

The FTAM file is busy. This error is a selection-related diagnostics notice, defined in ISO 8571-3.

11808 FTAM FILE NOT AVAILABLE

The file is not available. This error code is a selection-related diagnos-tics notice, defined in ISO 8571-3.

11809 FTAM CREATE OVERRIDE NOT POSSIBLE

The file already exists, recreation is not possible. This error code is a selection-related diagnostics notice, defined in ISO 8571-3.

11811 REQUESTED FTAM ACCESS VIOLATES PERMITTED ACTIONS

The requested FTAM access is in violation of the permitted actions. This error code is a selection-related diagnostics notice, defined in ISO 8571-3.

11812 FTAM ATTRIBUTE CANNOT BE CHANGED

The FTAM attribute cannot be changed. This error code is a file man-agement related diagnostics notice, defined in ISO 8571-3.

11813 BAD FTAM ATTRIBUTE VALUE

Bad FTAM attribute value. This error code is a file management related diagnostics notice, defined in ISO 8571-3.

11814 FTAM OPERATION NOT AVAILABLE

The FTAM operation not available. This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11815 FTAM OPERATION NOT SUPPORTED

Page 191: DX Error Messages

DN987378Issue 24-0

191

General Error Messages of System DX error messages

Id:0900d8058077e097

The FTAM operation is not supported. This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11816 FTAM CONCURRENCY CONTROL NOT AVAILABLE

The FTAM concurrency control is not available. This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11817 FTAM LOCAL FAILURE

FTAM local failure (unspecific). This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11818 FTAM LOCAL DEVICE FAILURE

FTAM local device failure (unspecific). This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11819 FTAM FUTURE FILE SIZE EXCEEDED

The FTAM future file size was exceeded. This error code is an access-related diagnostics notice, defined in ISO 8571-3.

11820 FTAM CONTENTS TYPE INCONSISTENT

The type of the FTAM-contents is inconsistent. This error code is a recovery-related diagnostics notice, defined in ISO 8571-3.

11821 FUNCTIONAL UNIT NOT SUPPORTED BY FTAM

Unsupported functional unit. This error code is an accociation-related diagnostics notice, defined in ISO 8571-3.

11822 UNSPECIFIC FTAM DIAGNOSTIC, RELATED TO ASSOCIATION MANAGEMENT

Unspecific error, related to association management. This error code is an association-related diagnostics notice, defined in ISO 8571-3.

11823 FTAM FILE CANNOT BE CREATED

The file cannot be created. This error code is a selection-related diag-nostics notice, defined in ISO 8571-3.

11825 FTAM OPERATION SUCCESSFUL

Successful FTAM operation.

11826 FTAM OPERATION UNSUCCESSFUL

FTAM operation unsuccessful.

11827 ERROR CODE NOT DEFINED IN FTAM

Diagnostics not relating to FTAM.

11828 NO MORE FTAM CONNECTIONS ALLOWED

No more FTAM connections allowed in the CVOPS process.

11829 GENERIC FTAM ERROR

Generic FTAM error.

11830 FTAM PROTECTION ERROR

FTAM protection error.

11831 FTAM ASSOCIATION ERROR

FTAM association error.

Page 192: DX Error Messages

192 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11832 FTAM SELECTION ERROR

FTAM selection error.

11833 FTAM MANAGEMENT ERROR

FTAM management error.

11835 INVALID FTAM MESSAGE

Invalid message relating to FTAM.

11836 FTAM LOCAL FILE OPENING FAILED

OOF process failed to open a local file.

11837 CLOSING OF FTAM LOCAL FILE FAILED

OOF process failed to close a local file.

11838 FTAM FAILURE IN READING LOCAL FILE

FTAM failure in reading a local file.

11839 FTAM FAILURE IN WRITING TO LOCAL FILE

FTAM failure in writing a local file.

11840 FTAM FAILURE IN READING LOCAL FILE ATTRIBUTES

FTAM failure in reading the attributes of a local file.

11841 FTAM FAILURE IN DELETING LOCAL FILE

FTAM failure in deleting a local file.

11842 FTAM DIRECTORY LISTING FROM LOCAL VFS FAILS

FTAM directory listing from local virtual file store fails.

11843 REQUESTED FTAM FILE OPERATION IS GOING ON

The requested FTAM file operation is still going on.

11844 FTAM LOCAL FILE CANNOT BE DELETED

A local file must not be deleted.

11845 FTAM APPLICATION ENTITY TITLE NOT FOUND

The FTAM application entity title is not found.

11846 FTAM PROTOCOL PRIMITIVE OR MESSAGE NOT ALLOWED IN THIS STATE

This FTAM protocol primitive or message is not allowed in this state.

11847 FTAM REMOTE ENTITY ABORTED CONNECTION

The FTAM remote entity has aborted the connection.

11848 ABNORMAL TERMINATION OF FTAM CONNECTION

Abnormal termination of FTAM connection.

11849 OPENING OF FTAM REMOTE FILE FAILED

The opening of a FTAM remote file has failed.

11850 THIS FTAM DOCUMENT TYPE IS NOT SUPPORTED

This FTAM document type is not supported.

11851 FTAM ACCESS ERROR

FTAM access error.

Page 193: DX Error Messages

DN987378Issue 24-0

193

General Error Messages of System DX error messages

Id:0900d8058077e097

11852 FTAM ACCESS REQUEST VIOLATES LOCAL SECURITY

A FTAM access request violates local security. This error code is a general FTAM diagnostics notice, defined in ISO 8571-3.

11853 FTAM SELECTION ATTRIBUTE MISMATCH

FTAM selection attributes are not matching. This error code is a selec-tion-related diagnostics notice, defined in ISO 8571-3.

11854 FTAM ACCESS CONTROL NOT AVAILABLE

FTAM access control is not available.

11855 NEGATIVE F-DATA-END INDICATION RECEIVED

The OOF process received the negative F-DATA-END indication. The negative F-DATA-END primitive is sent by the responder to indicate that the F-READ action was unsuccessful. The F-DATA-END primitive relates to the end of data transfer service, defined in ISO 8571-3.

11856 F-CANCEL INDICATION RECEIVED

The OOF process received the F-CANCEL indication. The responder has cancelled the FTAM data transfer service by issueing the F-CANCEL primitive. The F-CANCEL primitive relates to the cancel data transfer service, defined in ISO 8571-3.

11857 NEGATIVE F-TRANSFER-END CONFIRMATION RECEIVED

The OOF process received the negative F-TRANSFER-END confirma-tion. It indicates an unsuccessful completion of a FTAM transfer. The F-TRANSFER-END primitive relates to the end-of-transfer service defined, in ISO 8571-3.

11858 NEGATIVE F-CLOSE CONFIRMATION RECEIVED

The OOF process received a negative F-CLOSE confirmation. It indi-cates that the action of releasing an existing FTAM file open regime was unsuccessful. The F-CLOSE primitive relates to the file close service, defined in ISO 8571-3.

11859 NEGATIVE F-DESELECT CONFIRMATION RECEIVED

The OOF process received a negative F-DESELECT confirmation. It indicates that the releasing of the binding between the FTAM file select regime and the file was unsuccessful. In spite of the negative confirma-tion, the selection regime is terminated. The F-DESELECT primitive relates to the file deselection service, defined in ISO 8571-3.

11860 FTAM LOCAL FILE OPERATION TIMER EXPIRED

The timer expired when an OOFTAM process was waiting for a local file operation.

11861 PARAMETER VALUE ALREADY REQUESTED

The maintenance mode parameter value is already as requested.

11862 INVALID TEST IDENTIFIER

An invalid scheduled test identifier has been used.

11863 TEST REPORT NOT FOUND FROM REPORT HISTORY

There was no test report available in the test report history for the requested test object.

Page 194: DX Error Messages

194 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11864 TEST ALREADY CREATED IN BSC

The test cannot be created because it has already been created in the BSC.

11865 PERMANENT VIRTUAL CIRCUIT BEING RESET - COTS USER MUST WAIT

The COTS user requested a transport connection over the X.25 PVC, although the PVC was already in use. The COTS user should send a new transport connection request after 180 seconds.

11866 PERMANENT VIRTUAL CIRCUIT STOLEN BY ANOTHER PROCESS

Another process has established a connection over the X.25 PVC although it had already been reserved. The old user cannot use the con-nection anymore, and it should issue an alarm if this error code is ever received.

11867 C-CHANNEL IS NOT FREE

The C-channel is not free.

11868 C2 CELL RESELECTION ACTIVE OR CBCH MOBILE ALLOCATION OVERFLOW IN SYSINFO 4

SYSINFO 4 has no space for the C2 cell reselection parameter because the CBCH mobile allocation list was too large.

11869 USE OF THIS RANGE IS NOT ALLOWED

The use of this range has been barred by UTPFIL.

11870 DATABASE DOES NOT EXIST IN BTS OR IN BSC

The BTS HW database does not exist in BTS or in BSC (no database in flash memory).

11871 NUMBER OF FUS OR CUS IS NOT CONSISTENT WITH THW DATABASE IN SW PACKAGE

Number of frame units or carrier units is not consistent with the hardware database which is in the BTS SW package.

11872 NUMBER OF FUS OR CUS IS NOT CONSISTENT WITH THE HW DATABASE IN FLASH MEMORY

The number of frame units or carrier units is not consistent with the hardware database which is in the flash memory.

11873 NUMBER OF FUS OR CUS IS NOT CONSISTENT WITH HW DATABASE IN SW PACKAGE (NO FLASH)

The number of frame units or carrier units is not consistent with the hardware database which is in the BTS SW package. No flash memory.

11874 INVALID EXTENDED CELL RADIUS, OR EXTENDED CELL FEATURE NOT IN USE IN BSC

The radius of the extended cell is invalid, or the extended cell feature is not used in BSC.

11875 ATM MUX VP TABLE CHECK SUM ERROR

The check sums of the Virtual Path Tables in the WO and SP sides of the ATM multiplexer do not match.

Page 195: DX Error Messages

DN987378Issue 24-0

195

General Error Messages of System DX error messages

Id:0900d8058077e097

11876 ATM MUX VP TABLE UPDATE ERROR

The updating of the Virtual Path Tables in the WO and SP sides of the ATM multiplexer was unsuccessful.

11877 STATISTICS INDEX ALREADY EXISTS

A statistics index for the connection already exists.

11878 NO FREE STATISTICS INDEXES AVAILABLE

All possible statistic indexes are already in use.

11879 PROTOCOL ALREADY DEFINED

The protocol is already defined.

11881 PROTOCOL DOES NOT EXIST

The protocol does not exist.

11882 D-CHANNEL SYSTEM IS NOT USED

The requested D-channel system exists, but it is not used by any element.

11883 VIRTUAL FILE STORE MUST BE LOCAL

The given virtual file store must be local.

11884 EITHER SOURCE OR DESTINATION VIRTUAL FILE STORE MUST BE LOCAL

Either the source or the destination virtual file store must be local when using the FTAM copy command.

11886 NO RESPONSE FROM OOFTAM WITHIN TIME LIMIT

There is no response from OOFTAM within the time limit.

11887 NO RESPONSE FROM OVFSRP WITHIN TIME LIMIT

There is no response from the OVFSRP program block within the time limit.

11888 NO RESPONSE FROM O7AMAN WITHIN TIME LIMIT

There is no response from the O7AMAN program block within the time limit.

11889 LOCKING NOT ALLOWED AS OPERATIVE STATE OF FLOATING TRX IS BL-FLO (LOCK BCF)

A floating TRX (BL-FLO) is used as BCCH TRX. Lock the BCF so you can lock the object.

11890 BASE BAND HOPPING NOT ALLOWED IN SECTOR THAT HAS FLOATING TYPE TRX

The operation is not allowed, as in the cell Base Band hopping and the floating type of TRX are defined simultaneously.

11891 INVALID FTAM FILESTORE PASSWORD

Invalid FTAM filestore password. This error code is an association-related diagnostic notice, defined in ISO 8571-3.

11892 V5 SUBSCRIBER

This subscriber is connected to the exchange via a V5 connection.

11893 DATA LOCKED PENDING REPROVISIONING

Page 196: DX Error Messages

196 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The data has been locked, pending reprovisioning.

11894 ATTRIBUTE HAS VALUE WHICH IS OUT OF VALUE RANGE DEFINED FOR IT

An attribute has a value, which is not one of the values defined for it.

11895 MAXIMUM NUMBER OF V5 INTERFACE MEASUREMENTS ALREADY EXISTS

The activation of the measurement failed because the maximum number of V5 interface measurements is already active.

11896 V5 INTERFACE IS ALREADY IN MEASUREMENT

The V5 interface is already being measured by another active measure-ment.

11897 CELL MUST BE BARRED DUE TO BCCH TRX FREQUENCY TYPE IS DEFINED AS SUPER-REUSED

Operation is rejected due to the configuration mismatch: BTS parame-ter BAR must be Y, if FTY of the unlocked (or to be unlocked) broadcast control channel TRX is super-reused.

11898 SRM NOT UPDATED

The data of SRM was not updated.

11899 THIS FUNCTION IS NOT SUPPORTED IN THIS I/O DEVICE

This error status is used when an I/O device cannot execute the requested function.

11900 BCF HW DATABASE ADMINISTRATION PROGRAM BLOCK (HAWADM) BUSY

The BCF HW Database Administration Program Block HAWADM cannot reserve new hands.

11901 INTERNAL ERROR IN BCF HW DATABASE ADMINISTRATION PROGRAM BLOCK (HAWADM)

Operation has been interrupted by an internal error in BCF HW Database Administration Program Block HAWADM.

11902 SIGNALLING UNIT LOAD RATE TOO HIGH

Operation has been interrupted because of too high load rate in signal-ling unit (BCSU).

11903 BCF ID NOT FOUND IN HW DATABASE MANAGEMENT SYSTEM

The BCF identity can not be found in BCF hardware database manage-ment system.

11904 NO ACKNOWLEDGE MESSAGE TO HW DATABASE UPLOAD/DOWNLOAD REQUEST

Acknowledge message to HW database download/upload request from loading program block (BTDOWN) is missing.

11905 HW DATABASE UPLOAD/DOWNLOAD END MESSAGE MISSING

The end message after HW database upload/download from loading program block (BTDOWN) is missing.

Page 197: DX Error Messages

DN987378Issue 24-0

197

General Error Messages of System DX error messages

Id:0900d8058077e097

11906 NO ACKNOWLEDGE MESSAGE FROM A-BIS O&M PROGRAM BLOCK (AOMPRB)

A-bis O&M program block (AOMPRB) has not replied with an acknowl-edge message to BCF non-volatile memory save/erasure request.

11907 HW DATABASE OPERATION INTERRUPTED BY VERIFICATION REQUEST FROM BCF

HW database verification request from BCF (sent during BCF reset) has interrupted previous HW database operation.

11908 ERROR IN SAVING HW DATABASE MANAGEMENT FILES TO DISKS

BCF HW database management files has not been saved to the disks on BSC. Changes made may not be updated permanently.

11909 HW DATABASE IS ATTACHED TO BCF(S)

The HW database has attachments and therefore can not be deleted from management system.

11910 HW DATABASE HAS NO ATTACHMENTS

The HW database has no attachments to BCFs.

11911 BCF HAS ALREADY AN ATTACHMENT IN PASSIVE STATUS

New attachment is prevented because of already attached hw database in passive status.

11912 BCF HAS NO ATTACHMENT IN PASSIVE STATUS

Passive HW database can not be activated or detachment is not pro-ceeded because of missing attachment in passive status.

11913 BCF HAS NO ATTACHMENT IN ACTIVE STATUS

No HW database is attached to active status in this BCF.

11914 NO HW DATABASE FOUND IN MANAGEMENT SYSTEM

No created HW database is found in BCF HW database management system.

11915 GIVEN DATABASES ARE OF DIFFERENT GENERATION

The generations of given databases are different and therefore replace-ment is not allowed.

11916 DATABASE ID ALREADY FOUND IN MANAGEMENT SYSTEM

The given database identity is already found in BCF HW database man-agement system.

11917 GIVEN FILE(S) BELONGS TO ANOTHER DATABASE

Given file(s) belongs to another already created database.

11918 LOCKING OF PHYSICAL FILE(S) INCLUDED IN CREATED DATABASE FAILED

The physical file(s) belonging to created database are not protected against writing and deleting.

11919 UNKNOWN HW DATABASE STATUS

The status of the HW database is unknown to management system.

Page 198: DX Error Messages

198 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11920 ERROR IN PHYSICAL FILE INQUIRY

The BCF HW database management system has failed in physical file inquiry and therefore database is not created.

11921 ERROR IN COLLECTING CONFIGURATION DATA

BCF HW database management system has failed in collecting BCF HW database configuration data.

11922 ERROR IN COLLECTING EXISTING DATABASE INFORMATION

BCF HW database management system has failed in collecting infor-mation of the existing databases.

11923 ERROR IN READING BCF HW DATABASE MANAGEMENT FILE (HDMFIL)

The reading of the file has failed.

11924 ERROR IN READING BCF HW DATABASE CONFIGURATION FILE (HDCFIL)

The reading of the file has failed.

11925 ERROR IN WRITING BCF HW DATABASE CONFIGURATION FILE (HDCFIL)

The writing to the file has failed.

11926 ERROR IN WRITING BCF HW DATABASE MANAGEMENT FILE (HDMFIL)

The writing to the file has failed.

11927 RECORD NOT FOUND IN BCF HW DATABASE MANAGEMENT FILE (HDMFIL)

The record containig wanted data was not found in file.

11928 RECORD NOT FOUND IN BCF HW DATABASE CONFIGURATION FILE (HDCFIL)

The record containig wanted data was not found in file.

11929 BCF HW DATABASE MANAGEMENT FILE (HDMFIL) FULL

The BCF HW database management file (HDMFIL) is full. More data-bases can not be created.

11930 INTERNAL MESSAGE NUMBER FAILS

The internal check number of messages between LOSUNGs is wrong, i.e. the check number in the reply message is not the same as that in the request message.

11931 TIME-OUT IN LOADING

The time supervision between the LOSUNGs has expired, i.e. the LOSSRC hand in the source computer unit has failed to send a reply message in time to the LOSDES hand of the target computer unit.

11932 WRONG LOADING SOURCE

In his loading request message the user has indicated a wrong loading source in the source computer unit.

11933 TIME-OUT ON SOURCE UNIT

Page 199: DX Error Messages

DN987378Issue 24-0

199

General Error Messages of System DX error messages

Id:0900d8058077e097

The transfer of the load module has failed because the time allotted for the source computer unit has expired.

11934 DIFFERENT PACKAGE ID

When loading, it was discovered in the source computer unit that the source and target computer units have different package identifiers, i.e. that they have different packages.

11935 LOADING NOT ALLOWED

Loading from one computer unit to another is not allowed, because the units have different new_pack or trial statuses.

11936 LOADING IS GOING ON

The process requesting loading is already undergoing loading.

11937 NO RIGHTS TO REMOVE

The process attempting to remove the load module does not have the rights to do so.

11938 NO MODULE TO REMOVE

There is no load module of that name to be removed.

11939 LOADING TIME-OUT

The loading of the load module was not successful in the time alloted.

11940 WRONG VALUE OF NEIGH_CELL_RANGE_LIMITS_PRM_C PARAMETER

The value of the neigh_cell_range_limits_prm_c parameter is wrong. The value must be between 0..7.

11941 PARAMETER DEFINITION NOT FOUND

The parameter definition is not found from the KADATA database.

11942 COMMAND CASES NOT FOUND

The command cases not found from the KADATA database.

11943 BLOCK NOT FOUND

The block of the command is not found from the KADATA database.

11944 PARAMETER RANGE NOT FOUND

The range for the parameter is not found from the KADATA database.

11945 EXECUTION PRINT-OUT NOT FOUND

The execution print-out of the command is not found from the KADATA database.

11946 PARAMETER VALUE NOT FOUND

The parameter value is not found from the KIDATA database.

11947 SERVICE NOT FOUND

The service is not found from the KIDATA database.

11948 POINT NOT FOUND

The point is not found from the KIDATA database.

11949 SUBSCRIBER NOT FOUND

The subscriber is not found from the KIDATA database.

Page 200: DX Error Messages

200 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

11950 SERVICE ALREADY EXISTS

The service already exists in the KIDATA database.

11951 POINT ALREADY EXISTS

The point already exists in the KIDATA database.

11952 SERVICE HAS SUBSCRIBERS

The service has subscribers and they have to be deleted before the service can be deleted.

11953 RADIUS EXTENSION FEATURE IS NOT IN USE IN BSC

This error code informs operator that this feature is not available.

11954 NO ACKNOWLEDGE MESSAGE TO BCF RESET REQUEST

Acknowledge message to BCF reset request from BTLARM program block is missing.

11955 DATABASE ID NOT FOUND

The database identity is not found in BCF HW database management system.

11956 PHYSICAL FILE(S) NOT DELETED

BCF HW database management system has failed in deleting physical database file(s) from the fixed disks of the BSC.

11957 OPERATION NOT SUCCEEDED ON BOTH DISKS

The BCF HW database operation has not succeeded on the both fixed disks in BSC.

11958 BCF AND DATABASE OF DIFFERENT GENERATIONS

The generations of the BCF and the HW database are different.

11959 HW DATABASE IN MANAGEMENT SYSTEM DIFFERS FROM HW DATABASE IN BCF

The active HW database attached to BCF in management system is dif-ferent from the database in BCF.

11960 PROCESS IS TOO BUSY TO EXECUTE REQUEST

The process is unable to carry out the requested job as it is already working on an unfinished job.

11961 HAND DESTROYS ITSELF

The hand destroys itself by giving the STOP command, because it cannot perform initialisations.

11962 NO SPACE FOR LOAD MODULE

There is no space in the target computer unit for the load module to be loaded.

11963 NO ROOM FOR LOAD MODULE

There is insufficient buffer space in the source computer unit for the load module to be moved to the target computer unit.

11964 LOAD MODULE NOT OK

There is an error in the load module: either the structure or the check sum is incorrect.

Page 201: DX Error Messages

DN987378Issue 24-0

201

General Error Messages of System DX error messages

Id:0900d8058077e097

11965 SUCH MODULE NOT LOADABLE

A load module of the given name was not found in the memory of the source computer unit.

11966 UNIMPLEMENTED INSTRUCTION

The service interpreter tries to execute an uninplemented instruction.

11967 UNDEFINED INSTRUCTION

The service interpreter has detected an undefined instruction code.

11968 DATABASE ERROR

Error in database operation.

11969 ASSIGNMENT MISMATCH ERROR

Datatype mismatch error in assignment statement.

11970 NO ROOM IN BOOKKEEPING TABLE

There is no room in bookkeeping for the information of the load module to be loaded.

11971 GUIDANCE STRING EXCEEDS ITS MAXIMUM LENGTH

A string formed for guidance purposes exceeds its possible maximum length.

11972 RANGE DEFINITIONS INCORRECT IN KADATA DATABASE

The KADATA database is incorrect on what concerns range definitions.

11973 KADATA HAS INCORRECTLY CODED PARAMETERS IN EXECU-TION DEFINITIONS

In KADATA, execution definitions do not match the parameters.

11974 KADATA EXECUTION DEFINITION INCORRECT, UNKNOWN TRANSACTION CALLED

The KADATA execution definitions include a call for an unknown trans-action.

11975 USER HAS NOT SUFFICIENT RIGHTS TO EXECUTE COMMAND

The user has not sufficient rights to execute the command.

11976 NO RESOURCE FOR REQUEST

There are insufficient resources for requesting the data of the load module. There is not enough space either for the bookkeeping copy or for the request record.

11977 REQUESTING NOT GOING ON

The using process has sent a follow-up request message, even though requesting has not even started yet.

11978 KADATA INCORRECT, PARAMETER IS OF AN UNKNOWN TYPE

KADATA has an incorrectly defined parameter type.

11979 SUCH REQUESTING NOT GOING ON

The using process has sent a follow-up request message, but its type is wrong, i.e. the user has initiated a request, but the follow-up request is of another type.

11980 KAISER FAILS TO RESERVE HAND

Page 202: DX Error Messages

202 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

KAISER is unsuccesful in hand reservation.

11981 GIVEN ASCII CHARACTER CANNOT BE TRANSLATED INTO A NUMERIC VALUE

The given ASCII character cannot form a numeric value.

11982 TRANSLATION TO NUMERIC VALUE PRODUCES TOO BIG A VALUE

The translation to a numeric value produces a result that does not fit in the range given for that constant.

11983 TRANSLATION TO NUMERIC UNSUCCESSFUL, FORMAT ERROR

The given ASCII string cannot be translated into a numeric value because of a format error in the string.

11984 SIGNALLING LINK(S) CANNOT BE TRANSFERRED TO BACK-UP PCM

The back-up PCM for an active signalling link does not exist. A possible state change to the PCM concerned may block the active signalling link.

11985 TRANSFERRING OF SIGNALLING LINK(S) TO BACK-UP PCM POSSIBLE

A back-up PCM for the active signalling link exists. A state change to the PCM concerned will not block the active signalling link.

11986 RESTART OF THIS PREPROCESSOR UNIT IS NOT DECLARED

The preprocessor unit is not declared to be restartable.

11987 PARALLEL RECOVERY JOB IS NOT ACCEPTED

A parallel recovery action is not accepted for execution.

11988 PARALLEL RECOVERY JOBS BY VARIOUS MML COMMANDS NOT ACCEPTED

MML commands from different terminals cannot be used to activate parallel recovery actions.

11989 PARALLEL RECOVERY JOB TO BE ACCEPTED BY USER APPROVAL

The parallel recovery action will be accepted for execution only at the users own risk. Acceptance will require the approval of the user.

11990 UNFINISHED HW DATABASE OPERATION IN BCF

There is an unfinished BCF HW database handling operation in BSC and no new operation can be begun.

11991 PARAMETER VALUE ALREADY EXISTS

The parameter value already exists in the KIDATA database.

11992 PARAMETER STORAGE ERROR

Erroneous parameter storage in database KADATA/KIDATA.

11993 FEATURE IS NOT IN USE

Requested optional feature is not available.

11994 THERE IS NO SUCH FILE BASENAME IN VIPARA

METOCH cant find in VIPARA the file basename used in primitive.

Page 203: DX Error Messages

DN987378Issue 24-0

203

General Error Messages of System DX error messages

Id:0900d8058077e097

11995 THE INFORMATION IN THE FILESPEC(S) IS INCORRECT

Errorneous information in the list of filespecs.

11996 THE PROCESSING OF THE OCH TAKES TOO MUCH TIME

Processing of the OCH takes too much time as result of errorneous exe-cution.

11997 FILE HANDLING FAILED

File handling failed.

11998 TTTCOF UPDATING FAILED

VIDAST failed to update TTTCOF file.

11999 DECIMAL POSITION NUMBER RESERVED

The Decimal Position number (DP) given is already reserved.

12000 L3 ADDRESS RESERVED

The L3 address is already used by another subscriber in the same V5 interface.

12001 CHAINED CELLS IN RAPID FIELD DROP OPTION IS NOT IN USE IN BSC

The chained cells in rapid field drop is not supported in the BSC.

12002 OPTION OPTIMIZATION OF MS POWER LEVEL IN HANDOVER NOT IN USE IN BSC

Optimization of the MS power level in handover is not supported in BSC.

12003 CUG HAS ALREADY BEEN DEFINED TO SUBSCRIBER

Closed User Group has already been specified to subscriber

12004 SUBSCRIBER HAS CUG INTERLOCK CODE

Subscriber has been already defined CUG interlock code.

12005 SUBSCRIBER HAS TOO MANY CUGS PROVISIONED

Mobile subcriber has too many CUGs.

12006 CUG INDEX ALREADY DEFINED TO SUBSCRIBER

Cug-index had been already defined to subscriber.

12007 ILLEGAL BS GROUP GIVEN

You have used basic service group code which has been defined as illegal for this particular operation.

12008 GIVEN BASIC SERVICE GROUP NOT FOUND

Provisioning of CUG supplementary service has been attempted to basic service group which subscriber does not have.

12009 INTRA CUG PARAMETERS CONFLICT

When ocb has been defined to a CUG , the same CUG cannot been defined as a preferential CUG.

12010 PREFERENTIAL CUG HAS NOT BEEN FOUND

Preferential CUG must be found amongst the CUGs given to a sub-scriber.

12011 OBJECT CLASS IS NOT SUPPORTED

Page 204: DX Error Messages

204 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The given object class is not supported by the local agent.

12012 LOADING PROGRAM BLOCK (BTDOWN) NOT READY FOR SERVICE REQUESTS

Loading program block (BTDOWN) is in start state and does not accept service requests.

12013 AUDIT NOT COMPLETED NORMALLY

V5.2 BCC protocol, AUDIT procedure, incomplete normal.

12014 ACCESS NETWORK FAULT

V5.2 BCC protocol, AUDIT procedure, connection incomplete, access network fault.

12015 USER PORT NOT PROVISIONED

V5.2 BCC protocol, AUDIT procedure, connection incomplete, user port not provisioned.

12016 INVALID V5 TIME SLOT

V5.2 BCC protocol, AUDIT procedure, connection incomplete, invalid V5 time slot identification.

12017 INVALID V5 2048 KBIT/S LINK

V5.2 BCC protocol, AUDIT procedure, connection incomplete, invalid V5 2048 kbit/s link identification.

12018 TIME SLOT IS PHYSICAL C-CHANNEL

V5.2 BCC protocol AUDIT procedure, connection incomplete, time slot being used as physical C-channel.

12019 PARAMETER TABLE WAS NOT DEFINED

The parameter table is not defined in the subscriber database.

12020 INTEGRITY CHECKING OF DATABASE FILE INTERRUPTED

The integrity checking of a database file has been interrupted in order to avoid overflow in the report file.

12021 HW DATABASE IDS SAME IN REPLACE

The BCF HW database to be replaced is same as the replacing HW database.

12022 DATA OBJECT TRANSLATION IN PROGRESS

The data object, e.g. a database or a file, is being translated. The updates to this data object are forbidden during the translation.

12023 TIME-OUT IN FIRST DATA

The preprocessor did not receive the first message in time.

12024 NEW PEELNK NOT FOUND FROM APPLICATION PACKAGE

The preprocessor cannot find the new PEELNK from the application package.

12025 INVALID APPLICATION PACKAGE LENGTH IN HEADER

The length of the application package, indicated in the header of the message, is not correct.

12026 PREPROCESSOR PACKET NAME ID OFFSET IS INVALID

Page 205: DX Error Messages

DN987378Issue 24-0

205

General Error Messages of System DX error messages

Id:0900d8058077e097

The offset of the packet name ID is not correct. The name ID offset is located in the header of the message.

12027 PREPROCESSOR PACKET CODE OFFSET IS INVALID

The code offset of an application package is not correct. The code offset is located in the header of the application package.

12028 INVALID PREPROCESSOR PACKET LOADING PLACE

The loading place of the application package is not correct. The loading place is located in the header of the package.

12029 PREPROCESSOR FIRST DATA MESSAGE IS TOO SHORT

The first data message received is too short. The preprocessor cannot decompress it correctly.

12030 PREPROCESSOR FLASH ERASING FAILURE

The preprocessor cannot erase the FLASH memory. This is a fatal error, because it is impossible to write a new application package in FLASH if it cannot be erased.

12031 PREPROCESSOR FLASH WRITING FAILURE

The preprocessor cannot write to the FLASH memory. The error is fatal, because the new application package cannot be programmed in FLASH.

12032 UNKNOWN MESSAGE TO PREPROCESSOR

The preprocessor does not recognise the message, because it is somehow messed up.

12033 PREPROCESSOR PROTOCOL ERROR IN FIRST DATA

There is some kind of protocol error in the first received data message. Maybe the message received is not the one it should be.

12034 PREPROCESSOR PROTOCOL ERROR IN REST OF DATA

There is a protocol error in the rest of the data messages. Maybe the preprocessor was waiting for the rest of the data messages and it received the last data message.

12035 REJECT CAUSE: UNSPECIFIED

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, unspecified rejection.

12036 REJECT CAUSE: ACCESS NETWORK FAULT

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, access network fault.

12037 REJECT CAUSE: ACCESS NETWORK BLOCKED

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, access network blocked (internally).

12038 REJECT CAUSE: CONNECTION ALREADY AT PSTN

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, connection already present at the PSTN user port to a different V5 time slot.

12039 REJECT CAUSE: CONNECTION ALREADY AT V5 TIME SLOT

Page 206: DX Error Messages

206 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, connection already present at the V5 time slot(s) to a different port, or to a ISDN user port time slot.

12040 REJECT CAUSE: CONNECTION ALREADY AT ISDN PORT

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, a connec-tion already present at the ISDN user port time slot(s) to a different V5 time slot(s).

12041 REJECT CAUSE: USER PORT UNAVAILABLE

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, user port unavailable (blocked).

12042 REJECT CAUSE: DEALLOCATION ERROR, INCOMPATIBLE DATA

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, deallocation cannot be completed due to incompatible data content.

12043 REJECT CAUSE: DEALLOCATION ERROR, INCOMPATIBLE V5 TIME SLOT

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, deallocation cannot be completed due to V5 time slot(s) data incompatibility.

12044 REJECT CAUSE: DEALLOCATION ERROR, INCOMPATIBLE PORT DATA

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, deallocation cannot be completed due to port data incompatibility.

12045 REJECT CAUSE: DEALLOCATION ERROR, INCOMPATIBLE TIME SLOT DATA

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, deallocation cannot be completed due to user port time slot(s) data incompatibility.

12046 REJECT CAUSE: USER PORT NOT PROVISIONED

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, user port not provisioned.

12047 REJECT CAUSE: INVALID V5 TIME SLOT

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, invalid V5 time slot identification(s).

12048 REJECT CAUSE: INVALID V5 2048 KBIT/S LINK

V.2 BCC protocol ALLOCATE/DEALLOCATE procedure, invalid V5 2048 kbit/s link identification.

12049 REJECT CAUSE: INVALID USER PORT TIME SLOT

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, invalid user port time slot(s) identification(s).

12050 REJECT CAUSE: V5 TIME SLOT USED AS C-CHANNEL

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, V5 time slot(s) being used as physical C-channel(s).

12051 REJECT CAUSE: V5 LINK UNAVAILABLE

V5.2 BCC protocol ALLOCATE/DEALLOCATE procedure, V5 link unavailable (blocked).

Page 207: DX Error Messages

DN987378Issue 24-0

207

General Error Messages of System DX error messages

Id:0900d8058077e097

12052 V5FPST FILE IS FULL

The V5FPST file is full.

12053 AS7 RESOURCE NOT AVAILABLE FOR ADDING NEW V5 ISDN USER PORT

The operation is not possible due to a lack of AS7 resources.

12054 INVALID SIGNALLING TYPE

The signalling type is incorrect.

12055 PLUG-IN UNIT MEMORY CHECKSUM ERROR

The checksum of a memory area in a plug-in unit is incorrect. The cal-culated checksum differs from the checksum stored in the plug-in unit.

12056 INVALID TEST OBJECT

Test object was not found or its value was incorrect.

12057 SUB TEST OBJECTS FOUND UNDER THE MAIN TEST OBJECT

Main test object cant be deleted because there were found sub test objects under the main test object.

12058 INVALID MODIFICATION REQUEST

Requested modification cant be done.

12059 UNDERLAYOVERLAY STATISTICS OPTION IS NOT IN USE IN BSC

This error code informs operator that this feature is not available.

12060 RNOS USAGE OPTION IS NOT IN USE IN BSC

This error code informs operator that this feature is not available.

12061 INCOMPATIBLE CARD TYPE

The card type is incorrect.

12062 THERE IS NO ANALYSIS FOR THE CARRIER ACCESS CODE IN THE CAC IDENTIFICATION ANALYSIS

A Carrier Access Code is added to a B-number, but it is not defined in the CAC Identification Analysis.

12063 CARRIER ACCESS CODE GIVEN BY CARRIER ACCESS CODE CHANGE ANALYSIS IS TOO LONG

A Carrier Access Code given by the Carrier Access Code change analysis is longer than the exchange is able to handle.

12064 C-CHANNEL DOES NOT EXIST

The C-channel does not exist.

12065 DELETION OF C-CHANNEL IS NOT ALLOWED

The deletion of the C-channel is not allowed.

12066 SERVICE REQUEST LOG IS NOT IN USE

The application does not use the Service Request Log.

12067 ATM MEASUREMENT OBJECT IS DELETED

An ATM measurement object is deleted while the measurement is active.

12068 MEASUREMENT TIME LIMIT HAS BEEN EXCEEDED

Page 208: DX Error Messages

208 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The measurement is deleted because the time limit for the measure-ment hand has expired.

12069 LOGICAL C-CHANNEL NUMBER ALREADY EXISTS

The logical C-channel number already exists.

12070 CROSS CONNECTION IN TEST STATE

The error code is set when xc is in test and there is an attempt to carry out a forbidden operation on the xc, e.g. it is forbidden to delete xc while it is in test state.

12071 TRANSACTION LOG FAILURE

The storing of the back-up mark into the database transaction log is unsuccessful.

12072 DATABASE BACK-UP IS IN PROGRESS

The database back-up is in progress when a new back-up request is sent.

12073 EVENT LOG STREAM NOT FOUND

The given event log stream is not found from the ELSPAR file.

12074 MAX EVENT LOG STREAMS IN UNIT

The maximum number of event log streams in the computer unit has been reached.

12075 EVENT LOG STREAM IS IN USE

Application(s) is (are) connected to the given event log stream.

12076 EVENT LOG APPLICATION NOT FOUND

The given event log application is not found from the EFCONF file.

12077 BUFFER COUNT LIMIT OF ELGSTR IS REACHED

The number of buffers allocated by ELGSTR has reached the maximum. No new buffers can be allocated before an allocated buffer is written to disk. If the last buffer becomes full, then new events are lost.

12078 ALLOCATION OF NEW BUFFER IN ELGSTR HAS FAILED

ELGSTR tried to allocate a new buffer, but an operating system routine returned an error status. If the currently used buffer becomes full, new events are lost.

12079 ELGDSK DID NOT ATTACH BUFFER

In reply to its disk save message ELGSTR has received a message indi-cating that ELGDSK did not attach the buffer to be saved. All events in the buffer are lost.

12080 OPERATION CANCELLED

The requested operation was cancelled due to an M-CANCEL-GET request.

12081 MAX EVENT LOG APPLICATIONS

The number of applications using the event log has reached its maximum.

12082 MMI-RESOURCE ALLOCATION TIME-OUT

Page 209: DX Error Messages

DN987378Issue 24-0

209

General Error Messages of System DX error messages

Id:0900d8058077e097

MMI-resource allocation timer expired.

12083 NOT ENOUGH SPACE FOR TEST OBJECTS

Requested test objects cannot be defined for test because there is not enough space for them.

12084 V5 LINK ID ALREADY EXISTS

The V5 interface link identifier already exists.

12085 COAFIL IS FULL

COAFIL is full.

12086 UNIT IS SPECIFIED EARLIER IN COAFIL

The unit is already in the COAFIL file.

12087 UNIT IS NOT SPECIFIED IN COAFIL

The unit is not found in the COAFIL file.

12089 NO ANSWER FROM VARATM

The VARATM program block has not answered within time supervision.

12090 NO ANSWER FROM PXNETM FOR V5 SUBSCRIBER DATA MODI-FYING REQUEST

PXNETM has not acknowledged a V5 subscriber information modifying request within the time limit to V5MANA.

12091 DECIMAL AREA RESERVED FOR THIS V5 INTERFACE IS FULL

The decimal area for this V5 interface must be enlarged.

12092 ET UNIT IS NOT IN TEST STATE

The exchange terminal is not in the test state. E.g. diagnostics and test functions (line loopback) cannot be performed in states other than TE-EX.

12093 NO WORKING SECMO PLUG-IN UNIT FOUND

No working SECMO plug-in unit is found in the computer unit. The requested service cannot be provided.

12094 REQUESTED OPERATION DOES NOT BELONG TO THOSE AVAIL-ABLE FOR OBJECT

The requested CMISE operation is not available for the target object.

12095 RAM MEMORY OF PLUG-IN UNIT FAULTY

The RAM memory of the plug-in unit is faulty.

12096 I/O MEMORY OF PLUG-IN UNIT FAULTY

The I/O memory of the plug-in unit is faulty.

12097 BCC ALLOCATION ERROR IN AN

BCC allocation error in access network.

12098 BCC DEALLOCATION ERROR IN AN

BCC deallocation error in access network.

12099 BCC HAND CREATION ERROR IN AN

BCC hand creation error in access network.

12100 BCCPRB DOES NOT ANSWER

Page 210: DX Error Messages

210 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

BCCPRB fails to answer within predefined time limit.

12101 BCC PROTOCOL ERROR

BCC protocol error in communication with access network.

12102 CONGESTION ON ROUTE

Congestion on given route.

12103 V5 SEMIPERMANENT CONNECTION ALREADY DEFINED

The given connection is already created.

12104 V5 SEMIPERMANENT CONNECTION DISTURBED

A V5 semipermanent connection is defined but disturbed.

12105 V5 SEMIPERMANENT CONNECTION NOT DEFINED

V5 semipermanent connection not defined.

12106 BAD V5 SEMIPERMANENT CONNECTION INFORMATION

Bad information or message when creating V5 semipermanent connec-tion.

12107 V5 SEMIPERMANENT CONNECTION FAILED IN SWICOP

The creation of a V5 semipermanent connection failed in SWICOP.

12108 NO ROUTE TO GIVEN SUBSCRIBER FOUND

No route to subscriber.

12109 SPVSEM DOES NOT ANSWER

The supervision of the V5 semipermanent connections has not started: SPVSEM does not answer.

12110 V5 SEMIPERMANENT CONNECTION SUPERVISION ERROR IN AN

The supervision of a V5 semipermanent connection does not start/stop.

12111 SSU NOT DEFINED OR NOT IN USE

SSU is not defined or is not in use.

12112 SWICOP DOES NOT ANSWER

SWICOP did not answer within the predefined time limit.

12113 VXADMI DOES NOT ANSWER

VXADMI did not answer within the predefined time limit.

12114 VSEPRB WORK FILE READ ERROR

VSEPRB work file read error.

12118 OBJECT NOT CREATED

The object has not been created.

12133 MAXIMUM NUMBER OF V5 INTERFACE MEASUREMENTS

Number of V5 interfaces in measurement is already at its maximum.

12134 UNBLOCKING UNSUCCESSFUL

The unblocking of the V5 interface did not succeed.

12135 V5 PORT BLOCKING TIME-OUT

A V5 port has been blocked longer than the allowed time.

Page 211: DX Error Messages

DN987378Issue 24-0

211

General Error Messages of System DX error messages

Id:0900d8058077e097

12136 CORRESPONDING BCF IS IN WRONG STATE FOR THE OPERA-TION

The corresponding BCF is not in the proper state for the operation.

12137 CELL IS IN MINIMUM CONFIGURATION

The cell is in minimum configuration due to clock failure. This means that only the BCCH-TRX is available.

12138 C-CHANNEL CREATION NOT ALLOWED

The creation of the C-channel is not allowed.

12139 TOO MANY TRXS DEFINED IN CELL IN NON-SYNCHRONISED SITE

If a base station is non-synchronous, only 1 TRX is allowed in a cell.

12140 NON-BCCH TRX UNLOCK NOT ALLOWED IN NON-SYNCHRO-NOUS SITE

Non-BCCH TRX unlocking is not allowed in a non-synchronous base station.

12141 SUBSCRIBER IS VIRTUAL SUBSCRIBER

The given subscriber exists but not in this HLR.

12142 LINKS ARE NOT IN SAME UNIT

Links are not in same unit. Check if DCS is already used by other unit.

12143 NO COLLECTIONS IN DATABASE

There are no collections in the database.

12144 UNKNOWN COLLECTION NAME

The name of the collection is unknown.

12145 NO DIRECTORIES IN DATABASE

There are no directories in the database.

12146 UNKNOWN DIRECTORY NAME

The directory name given in the command cannot be found.

12147 NO DIRECTORIES FOR THIS COLLECTION

The collection defined has no directories.

12148 INCORRECT TARGET TYPE

The interrogation can be executed only if the target type is defined as a collection (target_type_t_coll) or as empty (target_type_t_none).

12149 NO RELATIONS IN DATABASE

There are no relations in the database.

12150 UNKNOWN RELATION NAME

The name of the relation is unknown.

12151 COLLECTION DEFINED HAS NO RELATIONS

The collection defined has no relations.

12152 NO COMPUTATIONAL RELATIONSHIPS IN DATABASE

There are no computational relationships in the database.

12153 UNKNOWN NAME OF COMPUTATIONAL RELATIONSHIP

Page 212: DX Error Messages

212 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The name given for the computational relationship does not exist.

12154 NO COMPUTATIONAL RELATIONSHIPS FOR GIVEN COLLECTION

There are no computational relationships for the collection defined.

12155 UNKNOWN TARGET TYPE

The target type is unknown.

12156 DIFFERENT ARITY IN TUPLE AND RELATION

The tuple arity used differs from the arity of the corresponding relation.

12157 TUPLE OF COMPUTATIONAL RELATIONSHIP MUST HAVE THREE VALUES

The tuple used for the computational relationships must have three values.

12158 TIME-OUT ON QUERY

The query time expired and the query was cancelled.

12159 QUERY COMPLETE

The query has been completed.

12160 POINT ITEM NOT FOUND

The point item cannot be found in the KIDATA database.

12163 VARIABLE DOES NOT EXIST

The given variable does not exist

12164 ADJACENCY ALREADY EXISTS IN DATABASE

There already is an adjacency for this linkage in the OEDATA database.

12165 CREATION OF ADJACENCY IN DATABASE FAILED

The creation of a new adjacency in the OEDATA database has failed.

12166 ADJACENCY DOES NOT EXIST IN DATABASE

The adjacency does not exist in the OEDATA database.

12167 CODE BLOCK NOT FOUND

The code block cannot be found in the KIDATA database.

12168 TIMERS FOR ALL USERS HAVE EXPIRED

Timers for all users of the ATM measurement have expired.

12169 IDENTIFIER LENGTH MUST BE EVEN

The identifier must consist of an even number of characters.

12170 TRX SOFTWARE DOWNLOADING STARTED

The operation is rejected because the downloading of the TRX software had started. The operation can be attempted again after a while.

12171 TRX SOFTWARE DOWNLOADING IN PROCESS

The operation is rejected due to the fact that the TRX software is being downloaded. Try the operation again after a while.

12172 STATE OF INTERFACE INCORRECT

The state of the interface is unknown or otherwise unfit for the situation.

12173 MORE DATA AVAILABLE

Page 213: DX Error Messages

DN987378Issue 24-0

213

General Error Messages of System DX error messages

Id:0900d8058077e097

More data records are available.

12174 TOO MANY FREQUENCIES PER BTS IN CASE OF RF HOPPING

Maximum number of frequencies per site has been exceeded in case of RF hopping.

12175 BTS HAS DETECTED MISMATCH BETWEEN CA AND MA

BTS has detected inconsistency between CA and MA.

12176 OUTGOING BUFFER OF ASWI IN ASM IS NOT EMPTY

The outgoing cell buffer must be empty during ASM switchover.

12177 ALL RECEIVING CHANNELS ARE ALREADY IN USE

The time slot of the MFST plug-in unit is free, but all the receiving channels of the current function are already in use. The signalling type used requires a free receiving channel before the service can be pro-vided.

12178 V5 INTERFACE TYPE IS 30B+D

The V5.2 interface is of type 30B+D.

12179 INCORRECT V5 INTERFACE TYPE

The type of V5 interface used is incorrect: e.g. type V5.1 is used when V5.2 30B+D should be used.

12180 POWER LEVEL CAN NOT BE USED IN THE TEST

Power level cannot be used in the test.

12181 TIMEOUT IN RECEIVING TEST RESULT FROM DSP

Timeout in receiving test result from DSP.

12182 TEST RESULT INVALID

Test result invalid (divide by zero not allowed in BER/FER calculation).

12183 BER/FER OUT OF RANGE

BER/FER out of range.

12184 ANTENNA TEST IS NOT SUPPORTED DUE TO EXTERNAL ANTENNA

Antenna test is not supported due to external antenna.

12189 V2 SUBSCRIBER LINE MEASUREMENTS NOT POSSIBLE

Measurements of subscriber lines connected via the V2 inter-face are not possible in this exhange.

12200 PDN CONTEXT ALREADY EXISTS

A PDN Context with the given context ID already exists.

12201 PDN CONTEXT LIMIT EXCEEDED

Subscriber already has the maximum possible number of PDN con-texts.

12202 COMMAND PARTLY SUCCESSFUL: MME NOT UPDATED

The data cannot be transfered to MME correctly. The Diameter inter-face rejects the given operation. However, the data has been stored in the HLR database.

Page 214: DX Error Messages

214 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12203 PDN CONTEXT DOES NOT EXIST

PDN context is not found from the subscriber in hostel database.

12204 THE DEFAULT PDN CONTEXT CANNOT BE DELETED

PDN context is not found from the subscriber in hostel database.

12205 THE GIVEN TARGET MME IS NOT ACTIVE

Connection to the given MME does not exist.

12206 A PREVIOUS LTE RESTORATION IS ONGOING

A previous LTE restoration operation is still running.

12207 EPS DATA ALREADY EXISTS

By EPS data creation, subscriber already has existing EPS data.

12208 EPS DATA DOES NOT EXIST

By EPS data update or interrogation, the required EPS data does not exist.

12209 EUTRAN ACCESS NOT ALLOWED

E-UTRAN access for subscriber is not allowed.

12210 MME ADDRESS DOES NOT EXIST

The required MME address does not exist.

12230 NO FREE KEY VERSION FOUND

No free version of the given key type was found.

12231 HANDLING OF OMXFIL FAILED

The handling of the OMXFIL file failed, probably due to a failure in the operating system routine.

12232 LINKAGE HAS MAXIMUM NUMBER OF ADJACENCIES

The creation of the manual adjacency failed because there already is a maximum number of adjacencies in the linkage.

12233 SNPA ADDRESS OF MANUAL ADJACENCY IS MISSING

The SNPA address of the manual adjacency is missing.

12234 MANUAL ADJACENCY IS NOT ACTIVE

The manual adjacency is not active, i.e. it is not connected to the ODEUPD program block.

12239 SYNCHRONIZATION TO EXTERNAL SOURCE FAILED

Synchronization to external source failed. BTS is synchronized to its internal clock.

12240 FATAL SYNCHRONIZATION FAILURE

Synchronization failed either to internal or external source. BTS is not synchronized to its internal clock.

12241 BTS DOES NOT SUPPORT HALF RATE CHANNELS

BTS does not support half rate channels.

12242 CANNOT OUTPUT METER NAMES ON DISK

Page 215: DX Error Messages

DN987378Issue 24-0

215

General Error Messages of System DX error messages

Id:0900d8058077e097

The creation of measurement failed, because meter names cannot be output on disk. If you want to use the meter names, use the operation & maintenance unit or the logical file as an output device.

12243 CHANGEOVER OF ACTIVE MAINTENANCE COMPUTER IN PROGRESS

Another computer is taking over the functions of the active maintenance computer.

12244 EXCLUSIVE RECOVERY ACTION IN PROGRESS

The recovery action in progress does not allow other simultaneous recovery actions.

12245 REQUESTED RECOVERY ACTION IS EXCLUSIVE

The recovery action that is requested excludes other simultaneous recovery actions.

12246 RECOVERY ACTION IN PROGRESS IN ACTIVE MAINTENANCE COMPUTER

The recovery action that is requsted cannot be performed because a recovery action is in progress in the active maintenance computer.

12247 RECOVERY ACTION IN PROGRESS IN THIS UNIT TYPE

A recovery action is already in progress in another unit of this type.

12248 RECOVERY AUTOMATONS RESERVED

Recovery automatons are reserved for other recovery actions.

12249 UNIT RESTART FAILED.

Unit restart which was activated by routine test failed.

12250 NOT-IN-USE TYPE RADIO TIMESLOTS (RTSL) HAVE TO BE LOCKED

The unlocking of a TRX is allowed only if the not-in-use type of channels are in the locked state.

12251 INCORRECT PACKET IDENTIFICATION

The packet identification which is derived during initial loading from another unit or from the BOTTOM table in the memory is not identical with the the data on the disk.

12252 INCOMPATIBLE DATA AND TYPE FORMAT

The type of data is incompatible with the given type format.

12253 SIZE OF DATA AND TYPE FORMAT INCOMPATIBLE

The size of the data is not compatible with the given type format.

12254 TOO MUCH DATA WRITTEN FOR ARRAY

There is too much written data to fit in the array.

12255 BLOCKING OF V5 USER PORT IS NOT POSSIBLE

The blocking of a V5 user port is not possible.

12256 TSL RESERVED

The TSL is already reserved.

12257 ONLY ONE LINK PER DPNSS PCM ALLOWED

Page 216: DX Error Messages

216 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The operator can create only one link per DPNSS PCM.

12258 CIRCUIT GROUP IS NOT MEMBER OF GIVEN CUG

Circuit group is a member of a closed user group, but is NOT a member of the given closed user group. For example: There could be an attempt to remove a circuit group from a given closed user group when that circuit group is not a member of the given closed user group, but is a member of some other closed user group.

12259 SYNTAX ERROR IN DATA TYPE FORMAT

Ther is a syntax error in the data type format.

12260 NOT-IN-USE TYPE OF RADIO TIMESLOTS (RTSL) HAVE TO BE UNLOCKED

The unlocking of a TRX is allowed only if the not-in-use type of channels are in the unlocked state.

12261 NAME OF EXCLUSIVE COLLECTION MISSING

The name of the exclusive collection must be given when it is used in the search tuple for the relations.

12262 NO ROWS CORRESPONDING TO GIVEN TUPLE

No rows corresponding to the given search tuple could be found in the relation or in the computational relationship.

12263 GIVEN COLLECTION IS EMPTY

The collection defined is empty.

12264 OBJECT INDEX UNKNOWN IN COLLECTION

No object with the given index can be found in the collection.

12265 READING OF DDL-TEXTS FROM DISK FILE FAILED

The reading of the DDL-texts from the disk file failed.

12266 RELATION IS EMPTY

The relation is empty.

12268 SEARCH KEY IS TOO LONG

The search key used is too long.

12269 SEARCH KEY IS TOO SHORT

The search key used is too short.

12270 COMPUTATIONAL RELATIONSHIP IS EMPTY

The computational relationship defined is empty.

12271 GIVEN DIRECTORY IS EMPTY

The directory is empty.

12272 TOO MUCH DATA FOR VARIABLE

The object has too much data to fit into the variable reserved for it.

12273 COUNT OF SUBSLOTS FOR SIGNALLING DIFFERS FROM OTHER TRXS OF THE CELL

Every TRX in the cell must have same count of subslots reserved for signalling.

Page 217: DX Error Messages

DN987378Issue 24-0

217

General Error Messages of System DX error messages

Id:0900d8058077e097

12274 VLR PARTLY UPDATED

VLR has not accepted all service data sent by HLR. It returns services which are not accepted in ACK message even though all service data is stored into HLR database.

12275 INTEGRITY CHECKING OF DATABASE IS ALREADY IN PROGRESS

Integrity checking of the requested database is already in progress. This error message is also given when the operator has requested a checking of a disk database, but a checking of another disk database is in progress.

12276 TIME-OUT ON CHECKING DATABASE INTEGRITY

Time-out on checking database integrity.

12277 UNKNOWN FREQUENCY BAND

Frequency band was not GSM or DCS.

12278 SUBSCRIBER PORTED

A subscriber has been ported.

12279 FR USERS IN SAME PIU

The creation of the frame relay (FR) measurement failed because there are two users on the same plug-in unit.

12280 VARIABLE ALREADY EXISTS

The variable name already exists.

12281 NOT ENOUGH SPACE ALLOCATED

There is not enough space allocated for the variable to store the required amount of data.

12282 CREATION OR DELETION OF SMUX CIRCUITS FAILED

Smux circuits couldnt be created or deleted. Given ET-PCM is not on Abis interface or given circuits are already in use. See computer log for more information.

12283 TOO MANY CHANNELS UNDER 386-BCSU

Because of limited memory capacity of BCSU having 386 processor the number of channels which is reserved for the BCSU is limited. This limit can be exceeded when new TRX is created or channel types of existing TRX are modified.

12284 AUTOMATIC RETURN NOT ALLOWED: WRONG RETURN CASE

You are trying to allow automatic return from or to a package wich is not active.

12285 AUTOMATIC RETURN NOT ALLOWED BECUASE IT IS NOT IN USE

This error has occurred because you are trying to allow automatic return when it has not been implemented in the program block BOLERO.

12286 AUTOMATIC RETURN NOT ALLOWED: OMU DOUBLED

Automatic return is not allowed when OMU is doubled.

12287 ANOTHER AUTOMATIC RETURN ALLOWED

Page 218: DX Error Messages

218 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

This automatic return cannot be allowed because another automatic return is already allowed.

12288 AUTOMATIC RETURN ALREADY ALLOWED

This automatic return is already allowed.

12289 AUTOMATIC RETURN NOT ALLOWED: PACKAGE MISSING

Automatic return cannot be allowed; you are trying to allow automatic return from or to a package which is missing.

12290 DISK FAILURE

Automatic return is not allowed because of disk failure.

12292 RETURN NOT DISALLOWED: NO AUTOMATIC RETURN ALLOWED

You cannot disallow automatic return when no automatic return has been allowed.

12293 RETURN NOT DISALLOWED: THE AUTOMATIC RETURN IS NOT ALLOWED

Automatic return cannot be disallowed because this automatic return is not allowed while another type of automatic return is allowed.

12294 HALFRATE OPTION IS NOT IN USE IN BSC

Halfrate option is not in use in BSC.

12295 MULTIBAND OPTION IS NOT IN USE IN BSC

Multiband option determines if both, single band and multiband mobiles can have adjacent cells from both GSM and DCS bands.

12296 INCORRECT STATUS OF DESTINATION PACKAGE

The status of the destination package must be BU (backup) or NW (new) when a change delivery is installed. Changes should not be installed on packages with status FB (fallback) or UT (untitled).

12297 TWO PACKAGES ALREADY EXIST IN DISK DIRECTORY

Installation of the change delivery to the software package failed because two packages already exist in the directory. There can be a maximum of two packages per disk directory, and this installation would result in a third one.

12298 CANNOT WRITE FILE TO DISK

The writing of a file to the fixed disk failed when installing the change delivery.

12299 NEW LOAD MODULE INFORMATION DOES NOT MATCH WITH CFLIST

The new information in the load module header does not tally with the information in the CFLIST file: either the delivery is faulty or the copying of the delivery to the fixed disk failed.

12300 NON-DEFAULT LOAD MODULE ALREADY EXIST IN DESTINATION DIRECTORY

Change delivery cannot be installed because a non-default load module already exists in the final destination directory (for example BLCODE or

Page 219: DX Error Messages

DN987378Issue 24-0

219

General Error Messages of System DX error messages

Id:0900d8058077e097

LFILES). Each directory can contain only two load modules with an identical name.

12301 COPYING ERROR WHEN INSTALLING MODULES FROM CDTEMP TO FINAL DIRECTORY

An error has occurred when copying the load modules of the change delivery from the CDTEMP temporary directory to the final directory. The error may be caused by a hardware fault or a full disk.

12302 LOAD MODULE SPECIFIED IN NEW MAFILE DOES NOT EXIST IN DESTINATION PACKAGE

The load module specified in the new MAFILE file of the change delivery does not exist in the destination package. The load module should be found in the destination package if it is not included in the change deliv-ery. The installation failed, possibly because the change delivery is erroneously built or the destination package is faulty.

12303 DATA OF DELETABLE LOAD MODULE DOES NOT MATCH WITH CFLIST

The deletion of the load module in the change delivery failed because the identification data of the load module does not match with the data in the CFLIST file. Thus the load module cannot be removed without a possible loss of data; the module may belong to another change delivery or a base delivery.

12304 DELETION OF LOAD MODULE FAILED WHEN REMOVING CHANGE DELIVERY

The load module could not be deleted when removing the change deliv-ery, possibly due to a hardware error.

12305 UNABLE TO WRITE HIFILE TO DISK WHEN DELETING CHANGE DELIVERY

The information on HIFILE file could not be written to disk while deleting the change delivery. The disk may be full. Error is returned from IFOLIB library.

12306 CANNOT READ HIFILE WHEN INTERROGATING CHANGE NOTES

The HIFILE file cannot be read when interrogating the history informa-tion in the change notes. The error is returned from DMXRTE or IOFLIB library.

12307 CANNOT READ CFLIST WHEN READING CONTENTS OF CHANGE DELIVERY

CFLIST file cannot be read while interrogating the information on the change delivery. The error is returned from DMXRTE or IOFLIB library.

12308 INCORRECT STRUCTURE OF FILE NAME/NUMBER CONVERSION TABLE

The structure of the File Name/Number Conversion Table (MEFILE) is incorrect.

12309 SERVICE NUMBER IDENTIFIER ALREADY RESERVED

The identifier of the service number to be created is already reserved.

Page 220: DX Error Messages

220 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12310 EXECUTION OF THE GENERIC MML-COMMAND TAKES TOO LONG

The execution of the generic MML-command takes an exceptionally long time.

12311 UNFINISHED CONNECTION TO TRX EXISTS

New connection cannot be established because there is already unfin-ished operation in this TRX.

12312 TRX NUMBER MISSING

The user has given Remote MMI connection request without TRX number in case of DE45/DF45.

12313 INTELLIGENT UNDERLAY-OVERLAY OPTION IS NOT IN USE IN BSC

Intelligent underlay-overlay is designed to allow operator to reuse fre-quencies more intensively and hence achieve higher radio network capacity.

12314 ZERO DATA LENGTH

Attempted to use a zero data length.

12315 ZERO NAME LENGTH

Attempted to use a variable name with zero length.

12316 INVALID SESSION VARIABLE NAME

The session variable name is invalid.

12317 TIME-OUT ON INTERROGATION OF V5 INTERFACE TYPE

You have interrogated the VXADMI program block about the V5 inter-face type (V5.1 or V5.2) by using the V5 interface id, but the inquiry has expired due to time supervision.

12318 V5 INTERFACE TYPE IS NEITHER V5.1 NOR V5.2

You have interrogated the VXADMI program block about the V5 inter-face type by using a V5 interface id, but the interface type is unknown to VXADMI.

12319 REPEATED INTERRUPTIONS ON SUPERVISED SEMIPERMANENT CONNECTION

An interruption on the supervised semipermanent connection has been detected and connection successfully re-established, but the connec-tion is still faulty during the following supervision period.

12320 THE SUBSCRIBER OF V5.2 INTERFACE DOES NOT EXIST UNDER SPVSEM SUPERVISION

The SPVSEM program block cannot find the V5.2 subscriber that was requeste from the work file.

12321 NO RESPONSE TO THE INQUIRY OF V5.2 SEMIPERMANENT CON-NECTION

Data on semipermanent V5.2 subscriber connection has been inquired from the VSEPRB program but there is no response during time super-vision.

Page 221: DX Error Messages

DN987378Issue 24-0

221

General Error Messages of System DX error messages

Id:0900d8058077e097

12322 ERROR IN CREATION OF HAND PROCESS

The BCCPRB program block has detetced an error in the creation of the hand process.

12323 NO ANSWER FROM AN TO AUDIT DESPITE RETRANSMISSION

No answer is received from the Access Node (AN) despite retransmis-sion of the AUDIT message.

12324 PROTOCOL ERROR IN MESSAGE FROM ACCESS NODE

A protocol error has been detected in the message received from the Access Node.

12325 SEMIPERMANENT CONNECTION RECOVERY HAS FAILED

The recovery of the semipermanent re-connection has exipred due to time supervision.

12326 NO ANSWER FROM ACCESS NODE DESPITE RETRANSMISSION OF ALLOCATION MESSAGE

No answer is received from the Access Node despite retransmission of the ALLOCATION message.

12327 HLR NOT UPDATED

HLR update failed.

12328 TOO MANY DUAL ARFCN VALUES

The creation of neighbour cell description fails because there are too many DUAL ARFCN values.

12329 CREATION OF CONNECTION FAILED ON START-UP

A V5 semipermanent connection was defined, but its creation failed on start-up of VSEPRB.

12330 LAST OBJECT ID IS SMALLER THAN FIRST OBJECT ID IN SEARCH TUPLE

The identifier of the last object in the search tuple is smaller than that of the first object.

12331 NO SUCH LOADING IDENTIFIER

The virtual loading using the given loading identifier does not exist.

12332 FAST MOVING MS OPTION IS NOT IN USE IN BSC

Fast moving handheld mobile stations handling in macro cells. If MS connected through macro cell is detected as slow moving MS, then it will be handed over to suitable underlying micro cell.

12333 NO FREE A-INTERFACE PCMS IN BCSU

Maximum number of A interface PCMs controlled by one BCSU exceeded.

12334 A-INTERFACE ET-PCM NOT FOUND

Given PCM is not A interface ET-PCM.

12335 ABIS INTERFACE ET-PCM NOT FOUND

Given PCM is not Abis interface ET-PCM.

12336 SMUX PLUG-IN UNITS NOT EQUIPPED

Page 222: DX Error Messages

222 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

SMUX plug-in units have not been equipped in both MCMUs.

12337 IDENTIFICATION OF CHANGE DELIVERY AND ACTIVE PACKAGE IDENTICAL

The identification data of the change delivery may not be identical with that in the directory of the active package when installing the change delivery.

12338 CFLIST OF THIS NAME CANNOT BE FOUND IN SOURCE DIREC-TORY

No CFLIST file with the given name can be found in in source directory. The file name must be identical with the name that is used in the change delivery.

12339 CHANGE DELIVERY WITH THIS NAME IS ALREADY INSTALLED

The installation failed because a change delivery carrying the given name has already been installed in this package. It is not possible to install a change delivery with a similar name twice. If the installation has terminated, you must first remove the change delivery and then install it again.

12340 CHANGE DELIVERY IDENTIFICATION OF NEW MAFILE DOES NOT MATCH WITH THAT GIVEN AS PARAMETER

The identification of the change delivery in the new MAFILE file does not match with the identification given as a parameter. If a new MAFILE is included in the change delivery, its change delivery identification must be identical with that of the change delivery to be installed.

12341 NO CFLIST FILE IN PACKAGE DIRECTORY

There must be a CFLIST file in the ASWDIR directory before the change delivery can be removed.

12342 CHANGE DELIVERY ID IN MAFILE DOES NOT MATCH WITH THAT GIVEN AS PARAMETER

The identification of the change delivery in the non-default MAFILE file must be identical with the identification to be removed, i.e. the identifi-cation given as a parameter.

12343 THE DATABASE OCCURRENCE IS ERRONEOUS

The given database occurrence does not exist in DBPARA or own unit is used as occurrence type when it has not been defined.

12344 TRX MAY HAVE MAXIMUM TWO RTSLS CARRYING SDCCH SUB-CHANNELS

It is possible to define maximum two RTSLs for TRX carrying SDCCH subchannels.

12345 MAXIMUM NUMBER OF VARIABLES STORED

A maximum number of variables has been exceeded and thus a new one cannot be stored.

12346 TOO MANY SIMULTANEOUS OPERATIONS

A maximum number of simultaneous, parallel operations have been exceeded. Wait until resources are free and try again.

Page 223: DX Error Messages

DN987378Issue 24-0

223

General Error Messages of System DX error messages

Id:0900d8058077e097

12347 FAULTY CHANGE PERCENTAGE IN CHARGING

The given change percentage causes an error for one of the following reasons: (1) the decrease is over 100% (2) the increase makes the pulse train exceed its maximum value (3) the increase makes the charge rate fall below its minimum rate (4) the decrease makes the charge rate exceed its maximum value.

12348 ATTRIBUTE RECORD ALREADY EXISTS

The number of the attribute record already exists.

12349 UNKNOWN ATTRIBUTE RECORD

This attribute record does not exist.

12352 ATTRIBUTE RECORD HAS REFERENCES

Reference is made to this attribute record from a combined attribute or from an external file.

12353 ERROR IN EVENT LOG CONTINUITY

The stream of events in the event log is not continuous.

12354 SUBSLOTS RESERVED FOR SIGNALLING MAY NOT CONTAIN TRAFFIC TYPE RTSLS

TRX RTSL configuration is illegal if subslots reserved for signalling contain traffic RTSLs (RTSL types TCHF, TCHH or TCHD).

12355 GROUP SWITCH TYPE ILLEGAL FOR HALF RATE RTSLS

Half Rate RTSLs require group switch type to be GSWB.

12356 CONTROL TYPE RTSLS NOT ALLOWED FOR FLOATING TRX

Only RTSL types TCHF, TCHH, TCHD and NOTUSED are allowed for floating TRX.

12357 ILLEGAL RECORD STATE

You were trying to change the state of a non-bitmapped record file; the only record state that can be given as a parameter for this type of file is record_state_t_update_c.

12358 CREATION OF REPORT FILE UNSUCCESSFUL

Signalled when report text file cannot be created to disk or creation of corresponding logical file failed. Log file of appropriate computer unit should be inspected for further information.

12359 UNKNOWN SIGNALLING LINK

The given signalling link does not exist.

12360 UNKNOWN TYPE OF NETWORK

The type of network defined does not exist.

12361 UNKNOWN SIGNALLING POINT

The signalling point does not exists.

12362 SUBSYSTEM UNKNOWN

The subsystem does not exist.

12363 ILLEGAL STATE OF CHANGE NOTE OF CHANGE DELIVERY

Page 224: DX Error Messages

224 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

You cannot remove a change delivery which has a change note in active or created state.

12364 CANNOT OPEN SOURCE FILE

Source file opening fails. This can be due to incorrect file (and/or) path name, bad IO-unit name or error in file open operation. Most likely incor-rect file name.

12365 CANNOT OPEN DESTINATION FILE

Destination file opening failed. There may be incorrect file name, for example non-existing directory path or incorrect IO-unit name. If file name is correct, this error code can mean that writing to directory is not allowed. Another cause is error in file open operation.

12366 ERROR IN FILE READING

File reading failed. More information can be read from error/test log files. Compression is not interrupted immediately after error in file reading (in order to avoid increasing algorithm complexity).

12367 ERROR IN FILE WRITING

Writing to destination file failed. Exceeding predefined destination file size is most likely reason to cause this error. More accurate information about error can be read from log file. Notice that compression is not interrupted immediately after file write error.

12368 SOURCE FILE IS TOO SMALL, COMPRESSION IS NOT STARTED

Size of source file is too small. Compression is not done, if size is smaller than 20 blocks (one block equals to 512 bytes, so limit size is about 10 kB).

12369 NO FREE HAND PROCESS TO DO THE JOB

There were no free hand process(es) to do the task.

12370 RENAME FAILED AFTER SUCCESSFUL COMPRESSION

During compression destination file has temporary name. Temporary file name is same as real one, except that extension in temp. file is .TZ and .Z in real destination file. If this error status appears, the compres-sion has succeeded, but renaming after compression failed for some reason. So the .TZ -file can be used.

12371 REQUESTED OPERATION HAS NOT BEEN IMPLEMENTED YET

Operation that user requested in compression service request message has not been implemented yet.

12372 UNDEFINED ERROR CODE

Undefined error during compression. Very unlikely to appear.

12373 REQUESTED TEST NOT SUPPORTED BY THE DEFINED SITE TYPE

Requested test is not possible with defined site type.

12374 C-CHANNEL HAS SUBSCRIBERS

The C-channel has subscribers.

12375 TOO MANY DISK VERSIONS OF LOAD MODULE IN DISK DIREC-TORY

Page 225: DX Error Messages

DN987378Issue 24-0

225

General Error Messages of System DX error messages

Id:0900d8058077e097

There are more than two disk versions of the load module in the disk directory when only two can be handled: the active version and the non-active version. Check why there are too many versions on disk.

12376 INVALID VERSION HANDLING REQUESTED

The version handling that was requested is invalid.

12377 FILE VERSION LIMIT REACHED

No new versions of the file can be created, as the maximum number of versions allowed are already in use.

12378 V5 INTERFACE HAS SUBSCRIBERS

The V5 interface has subscribers.

12380 PAGE WHICH CAUSED THE PAGE FAULT IS PRESENT

The PAGLIB library generates this error when the page fault handler detects that the page which caused the page fault is present.

12381 ADDRESS OUTSIDE PHYSICAL RAM

An attempt was made to access an address which is outside the physical RAM area and not visible in any linear window.

12382 PAGE TABLE ENTRY INVALID

The page cannot be fetched because there is invalid information in the page table entry.

12383 PAGING IS NOT IN USE

This service can be used only when paging is in use.

12384 PAGING HAS ALREADY BEEN INITIALIZED

Paging has already been initialized, i.e. pagin is set either to be used or not, and it cannot be re-initialized.

12385 AREA OF VIRTUAL MOVE OUTSIDE DRAM

Virtual move failed because the area defined (source and/or destina-tion) lies outside the scope of the physical DRAM.

12386 ALL PAGES ARE NOT PRESENT

One or several of the pages defined are not present.

12387 AT LEAST ONE PAGE IS ALREADY PRESENT

One or more of the memory pages are already present.

12388 AT LEAST ONE OF THE PAGES IS LOCKED

One or more of the memory pages is locked.

12389 PAGING HANDLER HAS NOT BEEN REGISTERED

The paging handler has not been identified.

12390 PAGING MEMORY AREA DOES NOT EXIST

The given paging memory area has not been set as non-present, or all its pages have become present and the information concerning the area has been destroyed.

12391 MEMORY AREA DOES NOT START AT PAGE BOUNDARY

The memory area concerned does not start at page boundary.

Page 226: DX Error Messages

226 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12392 PAGES ARE OUTSIDE THE MEMORY AREA

One or more of the pages is outside the boundaries of the given memory area.

12393 INCORRECT LENGTH OR STARTING POINT OF MEMORY

The given memory area is currently registered with a different starting address or length information.

12394 INVALID PARAMETERS

One or more of the parameters of the service routine call are invalid.

12395 PAGE GROUP SIZE IS INVALID

The size of the page group is invalid.

12396 PAGLIB FULL

The service cannot be provided because the internal structure of the PAGLIB library does not allow any more data.

12397 ACCESS DENIED TO GIVEN PHYSICAL MEMORY AREA

The given area in the physical memory contains paging data structures and thus it cannot be mapped to a linear window.

12398 ILLEGAL LINEAR WINDOW SIZE

The size given for the linear window is invalid; it must not be 0.

12399 TSL HAS SUBSCRIBERS

The time slot has subscribers.

12400 LOAD DESTINATION LIST FULL

The load destination list of the PFMEMF program block is full.

12401 VIRTUAL LOADING LIST FULL

The virtual loading list of the PFMEMF program block is full.

12402 TIMEOUT ON PAGE WAITING

The missing page of the memory file has not arrived in time.

12403 INCORRECT VALUE RANGE FOR PARAMETERS

The range of values defined for the two parameters on the same loop level do not match.

12404 RESERVED FOR OPERATOR SERVICES

The subscriber cannot be deleted and the subscriber position number cannot be changed if the given position number is reserved for operator services.

12405 DECIMAL POSITION AREA WAS NOT FOUND

The decimal position area that was given could not be found in the sub-scriber database.

12406 DECIMAL POSITION AREA IS NOT FREE

The decimal position area that you were trying to reserve in the sub-scriber database is already at least partly reserved.

12407 NO SUCH V5 SUBSCRIBER

There is no V5 subscriber of the given type in the subscriber database.

Page 227: DX Error Messages

DN987378Issue 24-0

227

General Error Messages of System DX error messages

Id:0900d8058077e097

12408 SUBSCRIBER CONNECTED TO INTERFACE

THE INTERFACE CANNOT BE REMOVED BECAUSE THERE IS A SUBSCRIBER CONNECTEDTO IT.

12409 TARIFF NOT ACCEPTED IN ORIGINATING OR INTERWORKING EXCHANGE

The originating exchange or the interworkin exchange does not accept the tariff sent with the CHG-message (ISUP2).

12410 TARIFF NOT ACCEPTED IN TRANSIT EXCHANGE

The transit exchange does not accept the tariff sent with the CHG-message (ISUP2).

12411 TARIFF NOT WITHIN LIMITS

The tariff is not within the given limits.

12412 MAXIMUM TARIFF AMOUNT EXCEEDED

The amount of tariffs exceeds the maximum amount allowed (6).

12413 NO RESPONSE TO CHG MESSAGE

No response (CHGA) is received to the CHG-message which has been sent.

12414 INCORRECT TARIFF FORMAT

Pulse charging has been given as the tariff format, but this format cannot be sent in the CHG-message (ISUP2).

12416 CONVERSION OF TARIFF IS NOT POSSIBLE

It is not possible to convert the tariff into pulse charging: the given tariff is either too high or too low for the pulses to be generated.

12417 TARIFF RECEIVED ABOVE CHARGING POINT

The tariff is received from an outgoing circuit although the own exchange should be the charging point used and charging from above this charging point (e.g. outgoing line) cannot be accepted.

12418 INCORRECT EVENT SIZE

The size of the event in the event log is incorrect.

12419 NO TRXS UNDER BCF

DE45/DF45 type BCF sites cannot be unlocked if there are no TRXs created under BCF.

12420 O&M LINK OUT OF ORDER

O&M link is down.

12421 DEFINED MASTER CLOCK TRX DOES NOT EXIST

If DE45/DF45 type BCF site is defined to be synchronized, defined Master Clock TRX must exist under BCF.

12422 ATTRIBUTE CONTENT DOES NOT MATCH WITH GIVEN DATA

The Match has given a negative result to the evaluation of the attribute against the data of the call.

12423 NON-DEFAULT DISK VERSION OF MAFILE ALREADY EXISTS IN DISK DIRECTORY

Page 228: DX Error Messages

228 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Change delivery cannot be installed if the disk directory already contains a non-default version of MAFILE file. This installation would create a new MAFILE or copies of a possible new MAFILE from the change delivery to the destination directory. It is likely that a previous change delivery is installed into the package but has not been taken into use.

12424 CHANGE DELIVERY ID IN CFLIST FILE AND FILE NAME DO NOT MATCH

There is a mismatch between the identification used in the CFLIST fileof the change delivery the name of the file. They must be identical.

12425 NO SUCH CONVERSION PROGRAM

Requested conversion program cannot be found. Check name and path of conversion program. Check if PEXHAN and/or CNVFAM should support this conversion program.

12426 OBJECT INSTANCE DOES NOT EXIST

The CMISE service primitive contains an object instance that was not found in the MIB (Managed Information Base) of the network element.

12427 OBJECT INSTANCE CONTAINS SUB-INSTANCES

The given object instance given in the delete CMISE service primitive contains sub-instances in the MIB (Managed Information Base) of the network element, and the deletion of such object instances is not allowed.

12428 LOAD MODULE OF CHANGE DELIVERY TO BE DELETED IS ACTIVE

The deletion of the change delivery failed, because a load module which is identical with the CFLIST file is active on disk. It is likely that the change delivery to be deleted is in use.

12429 NO ANSWER FROM MEMDAT

A disk updating was requested from MEMDAT, but it does not answer.

12430 SRMEAS IS BUSY, NO UPDATES ALLOWED

SRMEAS is busy and will not allow updates now. Please wait a few minutes and try again.

12431 AT155 -CONNECTION INDEX FOR FRAME RELAY FULL

No free connection indices could be found in the space reserved for the fra2m/AT34 connections of the AT155 cards in the connection index.

12432 AT155 CONNECTION INDEX FOR AT34 CONNECTIONS FULL

No free connection indices could be found in the space reserved for the fra2m/AT34 connections of the AT155-cards.

12433 LOADING FAILED: UNEQUAL DATA LENGTH

The file cannot be loaded, because the length of data in the source and destination file are not equal. The difference may be in the load module, header, bitmap or data.

12434 UNCONTROLLED CHANGE OF DEFAULT PACKAGE

Page 229: DX Error Messages

DN987378Issue 24-0

229

General Error Messages of System DX error messages

Id:0900d8058077e097

The software package has been changed to another one by automatic return due to an error during the previous restart of the OMU.

12435 SYSTEM RESTART WHILE OMU NOT IN TRIAL

The system has been restarted while the undoubled OMU was not set in trial configuration.

12436 INCORRECT CONTENT IN RECORD

The content of the record is, at least partly, incorrect; i.e. the record does not contain the information it should.

12437 INCORRECT RECORD TYPE

The record is not of a type that is allowed. The type used may not exist or no reference is allowed to this record type.

12438 PARSING OF THE LOGICAL EXPRESSION FAILED

The parsing of the logical expression failed because the given expres-sion is not in line with the syntax.

12439 CONTROLLED EXIT FROM OCH

The operations of the OCH have been interrupted in a controlled manner, i.e. the MAOPRB program block has interrupted the current operation, but no error message has been sent to the CMIP interface.

12440 CALL COMPLETION TO BUSY SUBSCRIBER

The subscriber type is Call Completion to Busy Subscriber (CCBS).

12441 DIFFERENCE IN RECORD- OR BYTE STRING LIST IN SOURCE AND DESTINATION

The given lists are different in length: the number of records in the record lists of the source and destination are different, or the number of byte strings in the byte string list vary, or the pair of byte strings (source - destination) differ in length.

12442 DISCREPANCY BETWEEN SOURCE AND DESTINATION FILE

The loading records failed, because the record size given in the source file and the destination file are different.

12443 ILLEGAL VIRTUAL LOADING ADDRESS

The virtual loading address used is illegal: the physical address of the source computer must be used.

12444 ADMINISTRATIVE STATE OF RELATED BCF IS INCORRECT

Related BCF is in incorrect administrative state for requested operation.

12445 PUP CONGESTION DETECTED

PMR User Part Prerouting function has detected congestion. (Used in NTN/DXT)

12446 PUP PREROUT NOT OK

PMR User Part prerouting function has not found available route to des-tination exchange. (Used in NTN/DXT)

12447 VIRTUAL FILE LOADING IN PROGRESS

The virtual loading of groups or files is still in progress.

Page 230: DX Error Messages

230 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12448 UNIT OPERATES AS FILE LOADING SOURCE

The unit works as the loading source for the files, and thus the unit cannot be restarted or its state cannot be successfully changed.

12449 UNIT OPERATES AS DATABASE LOADING SOURCE

The unit works as the loading source for the databases, and thus the unit cannot be restarted or its state cannot be changed.

12450 STATE CHANGE NOT POSSIBLE DURING RESTART

The state of the unit cannot be changed during restart of the unit.

12451 FLASH OPERATION GOING ON

Unfinished flash memory operation going on.

12452 WINDOWED FILE ACCESS SERVICE ALREADY EXISTS

The windowed file access service already exists in the system. This error situation occurs when the call for the program wfa_init_r() in the WFALIB library is repeated within the same process.

12453 PCM-TSL ALREADY RESERVED

The given PCM-TSL is already reserved.

12454 CCBS SUBSCRIBER ALREADY EXISTS

A CCBS subscriber already exists in this exchange.

12455 PRIVATE NETWORK PARALLEL NUMBER

Parallel number of a private network.

12456 MIB DATABASE IS FULL

The Management Information Base (MIB) is full and therefore no new object instances can be created.

12457 NAME ALREADY EXISTS

This is general error code which indicates that defined name already exists in analysis.

12458 NON-EXISTENT FTAM FILE

FTAM file does not exist. This error is selection-related diagnostics notice, defined in ISO 8571-3.

12459 NO ET FOR PCM

There is no ET for the given PCM circuit.

12460 END OF MML SESSION

With this status MMIMAN tells SEESAM that MML-session is ended. SEESAM tells with this status to MMIMAN that whole dialogue is over.

12461 DESTINATION SELECTION REQUEST

With this status MMIMAN requests destination selection service from SEESAM.

12462 DISK UNIT HAS INCORRECT WORKING STATE WHEN INSTALLING OR REMOVING CHANGE DELIVERY

The main working state of the disk unit must be WO when you are installing or removing a Change Delivery. Alternatively you can also use state SE-NH, in which case the unit data is ignored.

Page 231: DX Error Messages

DN987378Issue 24-0

231

General Error Messages of System DX error messages

Id:0900d8058077e097

12463 DISK UNIT DOES NOT EXIST IN THIS NETWORK ELEMENT

The disk unit given in the CFLIST file does not exist in this network element.

12464 TIMEOUT OCCURRED DURING PREROUTING

PMR User Part library returns this error code if it does not get response to prerouting message within time limit.

12465 DIRECTORY TABLE IS CORRUPTED

The directory table used by the service provider of the windowed file access has corrupted. More than one directory table records have been marked as invalid. Recovery procedure cannot be executed and the contents of the file for the windowed file access service are damaged.

12466 PARALLEL NUMBER OF PRIVATE NETWORK PARALLEL NUMBER

Parallel number to parallel number of private network.

12467 RSU SUBSCRIBER PRIVATE NETWORK PARALLEL NUMBER

Parallel number to RSU subscriber of private network.

12468 PARALLEL NUMBER OF RSU PRIVATE NETWORK PARALLEL NUMBER

Parallel number to private network parallel number of RSU subscriber.

12469 ANNOUNCEMENT NUMBER HAS BEEN DEFINED FOR SUB-SCRIBER

The subscriber number is in the NUMBER CHANGED state and the announcement number has been defined.

12470 NO CALL FORWARDING EXCEPTION

The subscriber has no call forwarding facility.

12471 ANALYSIS FOR CENTREX ADDITIONAL OUT-LINE NUMBER WAS NOT FOUND

Centrex additional out-line number was not found in Centrex additional out-line number analysis.

12472 AD&C SUBSCRIBER ALREADY EXISTS

AD&C subscriber already exists in this exchange.

12473 RCSC SUBSCRIBER ALREADY EXISTS

Reminder Call with Charging subscriber already exists in this exchange.

12474 RCSN SUBSCRIBER ALREADY EXISTS

Reminder Call without Charging subscriber already exists in this exchange.

12475 ERROR IN DATA LENGTH

Data length does not match with the one given in the load module.

12476 BAD CONNECTION TYPE

Connection type of Transport Pipe Provider is bad.

12477 BAD CONNECTION END POINT

Connection End Point which is sent by Transport Pipe User is bad.

12478 OPERATION IS NOT AVAILABLE

Page 232: DX Error Messages

232 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Transport Pipe Provider has a state where execution of this operation is not possible.

12479 COTS DOES NOT RESPOND

Timer which supervises COTS (Connection Oriented Transport Service ) interface has expired.

12480 TRANSPORT PIPE USER DOES NOT RESPOND

Timer which supervises Transport Pipe User has expired.

12482 COTS HAS CANCELLED THE REGISTRATION

Connection Oriented Transport Service has cancelled registration.

12483 TRANSPORT PIPE USER HAS CANCELLED THE REGISTRATION

Transport Pipe User has cancelled registration.

12484 TRANSPORT PIPE PROVIDER HAS CANCELLED REGISTRATION

Transport Pipe Provider has cancelled registration.

12485 INITIALIZATION OF THE INTERNAL CONNECTION MATRIX IN MFST-S PLUG-IN UNIT FAILED

A defect in internal connection matrix operation has occured at the ini-tialization phase of the MFST-S plug-in unit.

12486 MAXIMUM NUMBER OF INSTANCES EXISTS ALREADY

Operator tries to create new object instance of managed object class via Q3 interface. Creation fails because there exists already maximum number of object instances in network element.

12487 INSTANCE IS NOT DELETED BECAUSE LOG IS NOT EMPTY

Operator tries to delete managed object instance via Q3 interface. Instance cannot be deleted, because log of instance is not empty.

12488 CIC NOT FOUND

The circuit identification code was not found in the CPCMSP file.

12489 UNABLE TO HANDLE EXISTING (OLD) MAFILE WHEN HANDLING CHANGE DELIVERY

The handling of the MAFILE file existing in the old package has failed while trying to install or remove the change delivery.

12490 UNABLE TO HANDLE NEW MAFILE IN CHANGE DELIVERY

There is something wrong in the new MAFILE file included in the Change Delivery: the structure may be faulty or the required load module is missing.

12491 ADMINISTRATIVESTATE AND DESTINATION ATTRIBUTECANNOT BE SIMULTANEOUSLY IN SET REQUEST

AdministrativeState attribute and Destination attribute cannot be in one SET-request at the same time.

12492 SERIAL NUMBER DOES NOT MATCH

The order of arriving messages is incorrect.

12493 CANNOT FIND LOAD MODULE IN CHANGE DELIVERY OR ITS VERSION DOES NOT MATCH

Page 233: DX Error Messages

DN987378Issue 24-0

233

General Error Messages of System DX error messages

Id:0900d8058077e097

Installation has been interrupted, because the load module included in the Change Delivery cannot be found in MAFILE file or the version data of the Change Delivery load module and the new MAFILE do not match (in case of new MAFILE included in Change Delivery). Either MAFILE file is erroneus or the Change Delivery is erroneusly built.

12494 UNKNOWN MAFILE STRUCTURE FOR CHANGE DELIVERY INSTALLATION

The SW2ADM Program Block does not recognize the structure of the MAFILE file.

12495 FIS NUMBER DOES NOT EXIST

First extension number does not exist (private network).

12496 LAS NUMBER DOES NOT EXIST

Last extension number does not exist (private network).

12497 CNS NUMBER DOES NOT EXIST

Call number suffix does not exist (private network).

12498 PNP NUMBER DOES NOT EXIST

Private network parallel number does not exist.

12499 DATABASE DATA DICTIONARY IS UNINITIALIZED

The initialization of data dictionary in the database has not been run and thus the data dictionary files are empty.

12500 FIRST PARALLEL NUMBER TO PRIVATE NETWORK

First parallel number to the private network.

12501 SECOND PARALLEL NUMBER TO PRIVATE NETWORK

Second parallel number to the private network.

12502 THIRD PARALLEL NUMBER TO PRIVATE NETWORK

Third parallel number to the private network.

12503 FOURTH PARALLEL NUMBER TO PRIVATE NETWORK

Fourth parallel number to the private network.

12504 FIFTH PARALLEL NUMBER TO PRIVATE NETWORK

Fifth parallel number to the private network.

12505 SIXTH PARALLEL NUMBER TO PRIVATE NETWORK

Sixth parallel number to the private network.

12506 SEVENTH PARALLEL NUMBER TO PRIVATE NETWORK

Seventh parallel number to the private network.

12507 EIGHTH PARALLEL NUMBER TO PRIVATE NETWORK

Eighth parallel number to the private network.

12508 NINTH PARALLEL NUMBER TO PRIVATE NETWORK

Ninth parallel number to the private network.

12509 FIRST PARALLEL NUMBER TO RSU PRIVATE NETWORK

First parallel number to RSU private network subscriber.

12510 SECOND PARALLEL NUMBER TO RSU PRIVATE NETWORK

Page 234: DX Error Messages

234 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Second parallel number to RSU private network subscriber.

12511 THIRD PARALLEL NUMBER TO RSU PRIVATE NETWORK

Third parallel number to RSU private network subscriber.

12512 FOURTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Fourth parallel number to RSU private network subscriber.

12513 FIFTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Fifth parallel number to RSU private network subscriber.

12514 SIXTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Sixth parallel number to RSU private network subscriber.

12515 SEVENTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Seventh parallel number to RSU private network subscriber.

12516 EIGHTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Eighth parallel number to RSU private network subscriber.

12517 NINTH PARALLEL NUMBER TO RSU PRIVATE NETWORK

Ninth parallel number to RSU private network subscriber.

12518 PARALLEL NUMBER TO FIRST PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the first parallel number of private network sub-scriber.

12519 PARALLEL NUMBER TO SECOND PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the second parallel number of private network sub-scriber.

12520 PARALLEL NUMBER TO THIRD PARALLEL NUMBER OF PRIVATE NETWORK SUBSCRIBER

Parallel number to the third parallel number of private network sub-scriber.

12521 PARALLEL NUMBER TO FOURTH PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the fourth parallel number of private network sub-scriber.

12522 PARALLEL NUMBER TO FIFTH PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the fifth parallel number of private network sub-scriber.

12523 PARALLEL NUMBER TO SIXTH PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the sixth parallel number of private network sub-scriber.

12524 PARALLEL NUMBER TO SEVENTH PARALLEL NUMBER OF PRIVATE NETWORK

Page 235: DX Error Messages

DN987378Issue 24-0

235

General Error Messages of System DX error messages

Id:0900d8058077e097

Parallel number to the seventh parallel number of private network sub-scriber.

12525 PARALLEL NUMBER TO EIGHTH PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the eighth parallel number of private network sub-scriber.

12526 PARALLEL NUMBER TO NINTH PARALLEL NUMBER OF PRIVATE NETWORK

Parallel number to the ninth parallel number of private network sub-scriber.

12527 PARALLEL NUMBER TO FIRST PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the first parallel number of RSU private network sub-scriber.

12528 PARALLEL NUMBER TO SECOND PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the second parallel number of RSU private network subscriber.

12529 PARALLEL NUMBER TO THIRD PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the third parallel number of RSU private network sub-scriber.

12530 PARALLEL NUMBER TO FOURTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the fourth parallel number of RSU private network subscriber.

12531 PARALLEL NUMBER TO FIFTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the fifth parallel number of RSU private network sub-scriber.

12532 PARALLEL NUMBER TO SIXTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the sixth parallel number of RSU private network subscriber.

12533 PARALLEL NUMBER TO SEVENTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the seventh parallel number of RSU private network subscriber.

12534 PARALLEL NUMBER TO EIGHTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Parallel number to the eighth parallel number of RSU private network subscriber.

12535 PARALLEL NUMBER TO NINTH PARALLEL NUMBER OF RSU PRIVATE NETWORK

Page 236: DX Error Messages

236 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Parallel number to the ninth parallel number of RSU private network subscriber.

12536 UNIT IS DUMPING DATABASE

The unit is dumping databases, and thus the unit cannot be restarted or its state cannot be changed.

12537 UNIT IS COPYING DATABASE

The unit is copying databases, and thus the unit cannot be restarted or its state cannot be changed.

12538 ISDN ABIS OPTION IS NOT IN USE IN BSC

ISDN Abis feature (which can be used for the Abis connection between the BTS and BSC) is not supported in the BSC.

12539 MS SPEED DETECTION OPTION IS NOT IN USE IN BSC

This feature determines the speed of the MS in GSM/DCS networks, so that the fast moving mobiles can be directed to macrocells and the slower mobiles respectively to microcells.

12540 C/I BASED HANDOVER CANDIDATE EVALUATION OPTION IS NOT IN USE IN BSC

The crucial principle of the feature is to estimate the level of the potential co-channel interference on each handover candidate cell and to use this information in the target cell evaluation procedure in order to direct MSs to cells which have the best signal quality.

12541 INCORRECT SUB-TSL PLACE

The value given for the SUB-TSL place is incorrect. In case of 32 kbit/s LAPD, the place of SUB-TSL is normally 4.

12542 PCM-TSL IS ALREADY IN USE

The given PCM-TSL is already in use.

12543 THERE IS NOT ENOUGH SPACE IN THE PCM CIRCUIT FOR THE FUNCTIONAL UNIT

The functional unit needs more PCM-TSLs than what is available in the given PCM circuit.

12544 ALL TIME SLOTS ARE ALREADY RESERVED

All time slots of the given PCM circuit are already reserved, so it is not possible to add any functional units to this PCM.

12545 INCORRECT SPEED

The speed given for the D channel is incorrect for this functional unit.

12546 INCORRECT NUMBER OF MONITORING LINES

The functional unit TDSC (actually DWS) can have 2, 10 or 16 monitor-ing lines.

12547 INCORRECT NUMBER OF FCSD LINES

The functional unit DSCC can offer 2, 4 or 6 FSCD lines.

12548 YOU CANNOT REMOVE TDSC BEFORE THE SUBSCRIBER NUMBER OF DWS IS REMOVED

Page 237: DX Error Messages

DN987378Issue 24-0

237

General Error Messages of System DX error messages

Id:0900d8058077e097

The subscriber number of DWS is actully connected to the functional unit TDSC, thus the subscriber number of DWS has to be removed before TDSC can be removed.

12549 DELETE SUBSCRIBER NUMBER BEFORE DSCC

An error occurred, because there is a subscriber number connected to the DSCC. Remove the subscriber number before you remove the func-tional unit DSCC.

12550 PREPARATION OF BACKGROUND DATA FAILED

The preparation of background data for background loading of the radio network plan has failed.

12551 ORDERED STATE CHANGE OF BACKGROUND DATA IS ILLEGAL

The state change of the background data is illegal.

12552 INTELLIGENT DIRECTED RETRY OPTION IS NOT IN USE IN BSC

The INTELLIGENT DIRECTED RETRY option is not in use in the BSC.

12553 MA LIST DOES NOT CONTAIN ENOUGH FREQUENCIES

The number of frequencies in the attached MA-list must be at least the number of the hopping TRXs (in cell) and maio_offset together.

12554 TRUNK RESERVATION OPTION IS NOT IN USE IN BSC

The Trunk Reservation option is not in use in the BSC. The purpose of Trunk Reservation is to allow the shared use of the TCH resources of a single BTS by GSM and MCN users.

12555 MAXIMUM LENGTH OF STRING VARIABLE IS 223 CHARACTERS

The length of the string variable (and string parameter) in MML macros cannot be more than 223 characters.

12556 SOME PACKAGES ARE NOT APPLICABLE

One or more of the packages proposed in the object creation are not applicable in this object class.

12557 VARIABLE IS DEFINED EITHER BY LENGTH OR AS NUMERAL

The variable in the MML macro should be defined either by indicating the length of the string variable or by typing NUMERAL, referring to the numeral variable.

12558 RESOURCE SHORTAGE IN WINDOWED FILE ACCESS

There is not enough resources in the windowed file access server to complete the requested task.

12559 ALARM SYSTEM COULD NOT CHECK IF THE OMC UPDATE IS ALLOWED

The alarm system could not check if sending the alarm to the OMC is allowed or not.

12560 BB HOPPING AND SUPER REUSE TRXS NOT ALLOWED TO EXIST SIMULTANEOUSLY

When feature intelligent underlay-overlay is in use, bb hopping and super reuse trxs are not allowed to exist simultaneously.

Page 238: DX Error Messages

238 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12561 RF HOPPING CELLS BCCH TRX NOT ALLOWED TO BE SUPER REUSE TRX

When intelligent underlay-overlay feature is in use, RF hopping works only if the cell configuration is one regular BCCH trx and one or more super-reuse-TRXs.

12562 ILLEGAL CELL CONFIGURATION FOR IUO AND RF HOPPING

When intelligent underlay-overlay feature is in use, RF hopping works only when the cell configuration is one regular BCCH trx and one or more super-reuse-TRXs.

12563 MAIO OFFSET TOO HIGH

MAIO offset is bigger than the number of frequencies in the used MA-list.

12564 THERE IS NO UNLOCKED BCCH TRX UNDER CELL

The cell must have an unlocked transceiver of the broadcast control channel (BCCH or CPBCH).

12566 PCM BELONGS TO OTHER OBJECT CLASS

This error code is used when the current PCM belongs to another object class.

12567 ERROR WHILE COMMUNICATING WITH ELGAME PROGRAM BLOCK

ELGAME program block does not respond to ZSKPRB program block or the message that is received from ELGAME contains an error code.

12568 TYPE OF ID IN NEW AND OLD PACKAGE DO NOT MATCH

The lenght of the package type in the new package does not match with that of the old one.

12569 CHANGING OF DP AREA HAS BEEN INTERRUPTED

The reserving or releasing of the decimal position area was interrupted. Part of the requested change was carried out. The reason for the inter-ruption and the area for which the operation was successful is written to the log.

12570 FAMILY TO BE SUPERVISED NOT FOUND

CPUPRO Program Block has received a supervision with a process family that has not been created for the computer.

12571 FAMILY HAS NO DYNAMIC LDT SLOTS

CPUPRO has received an order for LDT supervision, but the given process family has no dynamically managed LDT slots.

12572 HAND GROUP NOT FOUND

CPUPRO has received an order for the supervision of hands in a hand type but the hand type that is given cannot be found.

12573 ILLEGAL PARAMETERS IN SUPERVISION ORDER

There are illegal parameter values in the supervision order received by CPUPRO.

12574 DRAM CONFIGURATION ERROR

Page 239: DX Error Messages

DN987378Issue 24-0

239

General Error Messages of System DX error messages

Id:0900d8058077e097

A configuration error was detected in the DRAM data of the CPU plug in unit.

12575 ERROR WHILE COMMUNICATING WITH USAPRO PROGRAM BLOCK

USAPRO program block does not respond or the message that is received contains an error code.

12576 ERROR WHILE COMMUNICATING WITH ZSKPRB PROGRAM BLOCK

ZSKPRB program block does not respond or the message that is received contains an error code.

12577 ERROR WHILE COMMUNICATING WITH SOWADM PROGRAM BLOCK

SOWADM program block does not respond or the message that is received contains an error code.

12578 DEFINED PACKAGE IS NOT DEFAULT PACKAGE

The package defined in the command is not the default package. This task can only be perfomed for the default package.

12581 NOT ENOUGH FREE TIME SLOTS

There are too few internal time slots (TSLs) available for a digital X.25 channel.

12582 ATTACHING MA-LIST TO 2ND GENERATION BTS TYPE IS NOT ALLOWED

Nokia 2nd generation BTS does not support rf-hopping in which MA-lists are needed, so attaching of MA-list to the Nokia 2nd generation BTS is not allowed.

12583 RF-HOPPING IS NOT ALLOWED TO 2ND GENERATION BTS TYPE

Nokia 2nd generation BTS site does not support rf-hopping.

12590 D-CHANNEL NOT BLOCKED

The D-channel is not blocked.

12591 THE READING OF NTN DATABASE FAILED

The reading of NTN database failed.

12592 UDATING OF NTN DATABASE FAILED

The data has not been updated in the NTN-database because of an updating error. In case of DST command, the addition of D-channel is cancelled.

12593 THE FIRST PCM CIRCUIT IS ALREADY RESERVED

The PCM-circuit given as the first one has already been reserved for another purpose.

12594 THE SECOND PCM CIRCUIT IS ALREADY RESERVED

The PCM-circuit given as the second one is already reserved for another purpose.

12595 BOTH PCM-CIRCUITS ALREADY RESERVED

Both of the given PCM-circuits are already reserved for other purposes.

Page 240: DX Error Messages

240 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12596 MA LIST NOT ATTACHED TO UNLOCKED RF-HOPPING BTS

MA-list is needed in rf-hopping, so MA-list must be attached to every unlocked rf-hopping BTS.

12597 LOCATION AREA NAME OR CODE ALREADY EXISTS

Location area name or code already exists in radio network files.

12598 LOCATION AREA DOES NOT EXIST

The location area cannot be found from the radio network files.

12599 LOCATION AREA CONTAINS SUBSCRIBERS

Subscribers are defined to the location area.

12600 MISMATCH IN PCM TYPE

The bit rate level (full rate, half rate or dual rate) that is given for the circuit to be added to the circuit group differs from the bit rate level of the first PCM circuit in the circuit group. The bit rate levels of the PCM circuits in the same circut goup must be equal.

12601 TEST CANNOT BE EXECUTED IF RX RTSL IS BCCH-CHANNEL

The test cannot be executed if RX RTSL is BCCH-channel.

12602 DATA HAS BEEN CHANGED

The data being handled has been changed during the execution of MML command.

12603 TOO MANY BTS O&M LINKS DEFINED

The O&M links have been defined more than one to the site of the D-type

12610 GSWB MUST BE INSTALLED WHEN MORE THAN 16 TRXS IN BCSU

GSWB must be installed when there are more than 16 TRXs in one BCSU.

12613 TOO MANY TCHS IN ONE SIGNALLING UNIT

Maximum number of traffic channels exceeded in one signalling unit.

12614 HOST CREATION FAILED

The creation of the TCP/IP remote host failed.

12615 HOST NAME IS ALREADY IN USE

The name of the remote host is already in use.

12616 IP ADDRESS ALREADY IN USE

This IP address is already in use.

12617 HOST DOES NOT EXIST

The given remote host does not exist.

12618 SERVICE CREATION FAILED

The creation of the TCP/IP service failed.

12619 SERVICE NAME ALREADY IN USE

The name given for the TCP/IP service already exists.

12620 SERVICE DOES NOT EXIST

This TCP/IP service does not exist.

Page 241: DX Error Messages

DN987378Issue 24-0

241

General Error Messages of System DX error messages

Id:0900d8058077e097

12621 PORT IS IN USE

The given port number is already used for another local TCP/IP service.

12622 SERVICE IS NOT BLOCKED

The administrative state of the TCP/IP service is not blocked.

12623 IP ADDRESS DOES NOT EXIST

The given IP address does not exist.

12624 PORT DOES NOT EXIST

The given port does not exist.

12625 NETWORK INTERFACE CREATION FAILED

Creation of the TCP/IP network interface failed.

12626 NETWORK INTERFACE ALREADY EXISTS

In this computer unit, there already exists a network interface with the given network interface type (if the type is Message bus) or with the same network interface type and plug-in unit index (if the type is Ether-net).

12627 NETWORK INTERFACE DOES NOT EXIST

The given TCP/IP network interface does not exist.

12628 NETWORK INTERFACE IS NOT BLOCKED

The administrative state of the TCP/IP network interface is not blocked.

12629 ROUTE ALREADY EXISTS

The TCP/IP route already exists.

12630 ROUTE CREATION FAILED

The creation of the TCP/IP route failed.

12631 NEXT HOP COMPUTER DOES NOT EXIST

The next hop computer does not exist.

12632 NEXT HOP CANNOT BE THE SAME COMPUTER

The same computer cannot be used as the next hop computer of the TCP/IP route.

12633 ROUTE DOES NOT EXIST

The given TCP/IP route does not exist.

12634 ROUTE IS NOT BLOCKED

The administrative state of the TCP/IP route is not blocked.

12635 TCP/IP PARAMETERS ALREADY EXIST

The TCP/IP parameters already exist.

12636 TCP/IP PARAMETERS DO NOT EXIST

The TCP/IP parameters do not exist.

12638 CONFLICT BETWEEN TRANSMISSION TYPE OF TRX AND NUMBER OF D-CHANNEL

Type of D-channel does not correspond to transmission type of TRX. An ISDN TRX must have an ISDN link and a normal TRX must have a fixed link.

Page 242: DX Error Messages

242 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12640 SUBSCRIBER ALREADY SEMIPERMANENT

The operator tried to create a semipermanent circuit for the subscriber, but the subscriber already has one in the database.

12641 NO SUCH SEMIPERMANENT SUBSCRIBER

The operator tried to delete a semipermanent circuit from the sub-scriber, but the subscriber does not have a semipermanent circuit in the database.

12642 BCF SW PACKAGE VERSION AND HW DATABASE INCOMPATIBLE

The active SW package in BCF does not support this HW database. Check the need of possible ASCII file in BCF and in HW database.

12643 HW DATABASES OF THE SAME TYPE BUT DIFFERENT LEVEL

The type of the HW databases is the same (DE21/DF12) but the level is different. Check the use of ASCII file in HW databases.

12644 HW DATABASE ATTACHED BUT COMPATIBILITY NOT CHECKED

The HW database was attached but the checking of SW package version was failed. Make sure that there is an active SW package attachment to the BCF in case (ZEWO:bcf_id). The activation of this HW database may not succeed.

12645 D-CHANNEL STATE MODIFICATION HAS FAILED

Abis D-channel state change modification request sent by the network management system has failed for some reason. PXADMI process has returned an error code to the Q3-agent (to the lapdLink-OCH).

12646 DELETION OF D-CHANNEL IS NOT ALLOWED

Deletion of Abis D-channel is not allowed because it is still used by some BCF or TRX instance.

12647 HARDWARE OF THE BSC IS NOT ADEQUATE FOR THE OPERA-TION

The hardware of the BSC is not adequate for the operation in question. The adequacy of the hardware is checked when the network manage-ment system is creating more than 256 Abis D-channels (so-called Large CapacityBSC).

12648 GIVEN RELATED LAPDLINK INSTANCE DOES NOT EXISTS IN BSC

In create request related Abis-lapdLink (D-channel) instance given by the network management system has not been created in the BSC.

12649 TDSC HAS NO SUBSCRIBER NUMBER

The functional unit TDSC has no subscriber number.

12650 INVALID OBJECT INSTANCE PARAMETER IN CMIS PRIMITIVE

The object instance parameter given fo the CMIS primitive is not semantically correct.

12651 CMIS PRIMITIVE CONTAINED SEMANTICALLY INCORRECT ACTION INFORMATION

CMIS primitive contained semantically incorrect action information.

12652 PASSIVE WARMING

Page 243: DX Error Messages

DN987378Issue 24-0

243

General Error Messages of System DX error messages

Id:0900d8058077e097

Wupman is going to use passive warming to warm up the group in ques-tion. (Not really an error situation, just a different type of warming is needed)

12653 HOT SPOT OPTION IS NOT IN USE IN BSC

This error code informs the operator that this feature is not available.

12658 THE DEVICE (OTHER THAN STM OR FUC) SENDS A NACK

The device (other than STM or FUC) sends a nack.

12660 ADMINISTRATIVE OPERATION IN PROGRESS

Another program block prevents the mml command from proceeding. Try again in a few seconds.

12661 LIU DOES NOT EXIST

The access could not be created because you have given one or more of the following parameters incorrectly: FU type, FU index, LIU type and LIU index. Check the correct LIU parameters and give the command again.

12662 ACCESS INDEX RESERVED

The given access index is already used for another access. Check the existing access IDs (command LAI) and give the command again with a free ID, or leave this parameter out and let the system automatically choose the first free ID.

12663 ACCESS NAME RESERVED

The given access name is already used for another access. Check the existing access names (with command LAI) and give the command again, using a free access name.

12667 ACCESS DATA INCONSISTENT

The command could not be executed. The system was not able to restore the data into original form, thus the data is now inconsistent. Try to delete the access and then give the command again. If this does not help, you can reboot the SVMANA Program Block and then give the command again.

12668 ACCESS DOES NOT EXIST

The access that was identified either with the access ID or the access name, was not found. Check the correct identifier (command LAI) and give the command again.

12669 COMMAND NOT EXECUTED

The command was not executed. The system, however, restored the data into original form, as it was before the command was given. Give the command again.

12670 ACCESS NOT IN LOCKED STATE

The administrative state of the access must be locked to execute this command. Change the state into locked (command LAG) and give the command again.

12672 ACCESS PROFILE DATA INCONSISTENT

Page 244: DX Error Messages

244 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The command was not executed. The system was not able to restore the data into original form, thus some discrepancy now occurs in the data. Try to delete the access profile (command LAE) and give the command again. If this does not help, you can reboot the SVMANA Program Block and give the command again.

12674 ENHANCEDFULLRATE OPTION NOT IN USE

The enhanced full rate option is not in use.

12675 INTERNAL ERROR IN PROGRAM BLOCK CPUPRO

The desired service cannot be provided due to an internal error in CPUPRO program block.

12678 INDEX ALREADY EXISTS

The given index is already assigned to an existing object.

12690 EMPTY ROUTE NOT UNLOCKED

It is not allowed to unlock a route that does not contain any VPCE Groups.

12692 ALARM UPLOAD IS BUSY

Alarm upload is currently going on, and another simultaneous alarm upload request is not allowed.

12693 LAPD EVENT LOGS ARE NOT ACTIVE

LAPD event logs are not active.

12695 EVENT LOG STREAM NUMBER IS INVALID

The given event log stream number is invalid: it is bigger than the maximum stream number in the ELSPAR or ESTADT File or it is bigger than the maximum number of event log streams in the unit.

12696 EVENT LOG STREAM ALREADY EXISTS

The given event log stream already exists, i.e. the event log stream number is already in use.

12697 B-CHANNELS ARE STILL IN USE

B-channels are still in use. The B-channels must be removed before the D-channel can be deleted.

12704 NO SPACE FOR UNIT TYPE IN REMOTE STATION

No more unit types can be saved in the given remote station.

12705 NO SPACE FOR UNIT INDEX IN REMOTE STATION

No more unit indexes can be saved in the given remote station.

12706 UPLOAD TYPE IS NOT SUPPORTED

The type of the upload request is not one of the constants given in the definition of upload_type_t data or the type is not supported by the current software.

12707 COPY TASK IS ABORTED BY REQUEST

Active copy task is terminated by request.

12708 COPY TASK ERROR LIMIT EXCEEDED

The error limit for the copy task has been exceeded.

Page 245: DX Error Messages

DN987378Issue 24-0

245

General Error Messages of System DX error messages

Id:0900d8058077e097

12709 TOTAL FILE COPY TIME EXCEEDED

The time limit for copying mass memory files has been exceeded.

12710 SINGLE FILE COPY TIME LIMIT EXCEEDED

The copy time for single mass memory file has been exceeded.

12711 UNKNOWN ID FOR COPY TASK

The identification given for the copy task in the mass memory cannot be used.

12712 ERROR WHILE DELETING USER SPECIFIC VALUES

The network element access control manager could not delete user-specific values. Use commands in IU-command group to delete values or to get more information.

12717 BUFFER NOT DETACHED

There is an attachment to the buffer.

12718 FAILURE IN BUFFER RELEASE

The buffer could not be released.

12719 FTAM MODIFY EXECUTED PARTLY CORRECTLY

This error code may appear when the FTAM modify has been executed and the filename has had wildcard(s). The error code indicates that at least one modify operation has been successful and at least one modify operation has been unsuccessful.

12720 FTAM FILENAME MODIFY NOT ALLOWED WHEN USING WILD-CARDS

Ftam filename modify is not allowed when using wildcards. Rename the files individially without wildcards.

12721 NO ESTADT FILE ON THE DISK

When creating a new event log stream, it is possible to use the old estadt file. However, if the ESTADT file does not exist on the disk, the creation of the new event log stream does not succeed.

12722 REFERENCE LOCATION AREA DOES NOT EXIST

The reference location area cannot be found from the radio network files.

12723 LOCATION AREA CONTAINS BASE TRANSCEIVER STATIONS

Base Transceiver Stations are defined to the location area.

12724 LOCATION AREA CONTAINS BASE TRANSCEIVER STATIONS AND SUBSCRIBERS

Base Transceiver Stations and subscribers are defined to the location area.

12725 TCP/IP PARAMETER CREATION FAILED

The creation of TCP/IP parameters failed.

12728 COMMUNICATION ERROR BETWEEN YESMAN AND TZIPPI PROGRAM BLOCK

Page 246: DX Error Messages

246 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

TZIPPI Program Block does not answer to the request initiated by YESMAN Program Block.

12729 SEMAPHORE TIME SUPERVISION EXPIRED

Time supervision on semaphore has expired.

12730 DATABASE BACK-UP COPYING NOT IN PROGRESS

Database has received a back-up copying termination request, but there is no back-up copying of database in progress.

12738 ACCESS PROFILE DOES NOT EXIST IN DATABASE

The specified access profile does not exist in the database.

12746 TARGET DOES NOT EXIST

The target does not exist in the database.

12754 VPTP EXISTS UNDER ACCESS

An attempt has been made to delete an access which still has existing vpis.

12759 CHANNEL ALREADY RESERVED FOR ANOTHER APPLICATION

The channel is already reserved for another application. Please try again later.

12760 NO SUCH DIRECTORY ON TAPE

The directory cannot be found on tape.

12761 NO SUCH FILE ON TAPE

The file cannot be found on tape.

12763 DEFINITIONS OR THEIR ORDER DO NOT CORRESPOND TO DEC-LARATIONS

The parameters must be defined in the order given in declaration, and the variables must be defined after the parameter definitions.

12767 DXT COMMERCIAL OPTION LIMIT REACHED

Attempt to add more units of the given type failed due to the commercial option limit.

12769 INCORRECT NETWORK INTERFACE TYPE

The type of network interface is incorrect.

12770 ILLEGAL COPY FILE LIST

The copy file list is illegal and thus cannot be handled.

12771 IMSI RESERVED

The IMSI number is already being used by another subscriber.

12786 CARRIER PAIR NUMBER IS INVALID

The carrier pair number is invalid. Carrier pair numbers can be 0, 1, 2, ..., 4095.

12790 COMPUTER UNIT HAS NO TCP/IP SERVICE

A local service cannot be created in a computer unit which does not have a service program block for TCP/IP data transfer.

12791 IP ADDRESS IS ILLEGAL

Page 247: DX Error Messages

DN987378Issue 24-0

247

General Error Messages of System DX error messages

Id:0900d8058077e097

The format of the IP address is incorrect or it is one of the forbidden addresses.

12792 WAGONS DATABASE IS FULL

There is no room for new data in the database.

12793 NAME SERVER IS NOT READY TO SERVE

The name server is not ready to serve. The computer of the name server is in the process of boot loading.

12797 UPC PARAMETER SETUP FAILED

The setup of UPC parameters for virtual connection failed.

12798 CHANGE OF PVP STATE FAILED

Changing the state of PVP connection failed.

12799 CHANGE OF PVC STATE FAILED

Changing the state of PVC connection failed.

12800 ACCESS STATE CHANGE FAILED

Change of access state failed.

12801 TOO MANY CONNECTIONS PER MESSAGE

The maximum number of connections per message has been exceeded.

12802 TOO MANY CONNECTIONS FOR ACCESS LINE

The maximum number of connections per access line has been exceeded.

12806 NO SUCH TRACING HAS BEEN ACTIVATED

No such tracing has been activated for the subscriber/imei; the trace origin does not match.

12807 PENDING TRACING HAS ALREADY BEEN SET

Pending tracing has already been set for the subscriber/imsi.

12808 PENDING TRACING HAS NOT BEEN SET

Pending tracing has not been set for the subscriber/imei.

12809 DB ARRAY IS FULL

DB array is full, no free space for new element.

12814 INVALID INTERRUPT

Unknown interruption.

12818 MAX. NUMBER OF ERRORS IN ONE SERVICE EXCEEDED

This error code indicates that the maximum number of errors in one service has been exceeded. If this happens during a transaction, the current procedure is stopped. It is a matter of hand process if the rest of the list members are to be handled separately. Index in ec_tag_t indi-cates the first list member that has not been handled.

12832 PAGING NOT UPDATED

The paging data of the WLL terminal have not been updated.

12834 OBJECT ALREADY EXISTS IN THE DB

Page 248: DX Error Messages

248 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

This error code is used by the data management services to indicate that the requested object is already in the database.

12840 IP ADDRESS NETWORK PART IS NOT SUITABLE

The network part of the IP address cannot be similar for the destination address of the route and for the IP address of the network interface in the same computer.

12841 INTERPRETING KADATA EXECUTION DEFINITION FAILS

The execution definition for MML commands in KADATA Database contains an illegal command or there is an error in the order of com-mands, thus the interpretation fails. It is also possible that the definition describes an erroneous execution.

12850 UNKNOWN GROUP

The requested group does not exist in the database.

12857 SUBNET NETWORK INTERFACE IS UNBLOCKED

The modification of the IP address is not possible, because a network interface in the subnetwork is unblocked. Or else the modification of the administrative state of the network interface is not possible, because the IP address network part of the network interface is different from the network part of the other IP addresses in the same subnetwork.

12858 INCORRECT IP ADDRESS NETWORK PART

The network part of the IP address differs from the network part of other network interfaces in the same subnetwork.

12859 BTS NOT FOUND IN RADIO NETWORK DATABASE

The base station has not been created into the database. There must be an existing BTS under which a transceiver or a Frequency Hopping System can be created.

12860 BTS POWER CONTROL PARAMETERS NOT FOUND IN RADIO NETWORK DATABASE

The power control parameters of the BTS have not been created into the radio network database.

12861 TERMINATION POINT IS NOT IN LOCKED ADMINISTRATIVE STATE

The operation requires the termination point to be in locked administra-tive state. Lock the termination point and give the command again.

12866 THE RESERVATION STATE IS ALREADY RESERVED

The reservation state is already reserved. The state cannot be changed to the value it already has.

12872 NEXT HOP IS BLOCKED

Route cannot be taken into use, i.e. its administrative state cannot be changed into unblocked because the next hop computer is blocked.

12879 COLLECTION FOR THE MEASUREMENT GOING ON

PUMPRB sends this error when the operator tries to modify measure-ment but collection for the measurement is going on.

12886 DISK FILE UPDATES PREVENTED

Page 249: DX Error Messages

DN987378Issue 24-0

249

General Error Messages of System DX error messages

Id:0900d8058077e097

Updates of disk-file copies of memory files are prevented.

12889 PXRECE HAS NOT ACKNOWLEDGED UPDATING REQUEST

Pxrece has not acknowledged the distribution table update request made by the ABIPRB. The ABIPRB has cancelled an ongoing switcho-ver.

12891 GIVEN VALUE IS ILLEGAL

The given value is illegal or it has caused some value in the database to become illegal.

12892 BTS_STATE_CHANGED MESSAGE NOT RECEIVED

The BSC has not received BTS_STATE_CHANGED message due to failed TRX configuration. TRX operative state will be set to BL_SYS.

12893 OBSERVATION ALREADY RUNNING

Observation has already been started and is running.

12894 THERE ARE TOO MANY BCFS IN ONE SIGNALLING UNIT

In creation of BCF (site type B or D) or in creation of TRX (site type F) or in O&M-link modification it was noticed that there will be too many BCFs in one signalling unit.

12895 DUMPING GOING ON

It is not possible to set prevention on disk-file updates of memory files while dumping is going on. Use DUPHAN-MML to find out who has set up prevention or to force prevention off, when possible.

12909 REQUESTED OPERATION NOT DEFINED FOR OBJECT CLASS OR ATTRIBUTE

The requested operation was not defined for the object class or attri-bute.

12910 ATTRIBUTE VALUE SUPPLIED MORE THAN ONCE IN REQUEST

An attribute value was supplied more than once in the request.

12911 CREATION WITH REFERENCE OBJECT NOT SUPPORTED

A reference object was supplied but creation with a reference object is not supported.

12912 OBJECT CONTAINS OTHER OBJECT INSTANCES

An object cannot be deleted because it contains other object instances.

12913 ATTRIBUTE SUPPLIED FROM PACKAGE THAT CANNOT BE INSTANTIATED

An attribute value was supplied for an optional attribute from a package that cannot be included in the object instance.

12917 RESERVING SOFTWARE CONFIGURATION OPERATION IS NOT ALLOWED

The reservation of resources for the desired software configuration operation is not permitted, because another operation is running and prevents a new simultaneous reservation, or the attempted operation is already reserved, and a duplicate reservation is not possible. Use the MML command WXP to display the operation execution conditions, and

Page 250: DX Error Messages

250 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

the command WXI to see the reservation situation. You may also have been left with a hanging reservation in some uncontrollable error situa-tion (eg. a spontaneous restart of OMU, or an interrupted MML session), and this reservation interferes with the execution of a new operation. You can suspect a hanging reservation, if the start time of an operation is unusually long compared to the time it normally takes to execute this operation. Release this kind of hanging reservation, using the MML command WX.

12918 UNKNOWN SOFTWARE CONFIGURATION OPERATION

The requested task cannot be performed, because the SW operation specified in the request is unknown.

12919 UNKNOWN TYPE OF SERVICE REQUEST

The service requestgiven to the SW configuration administration is unknown.

12920 SW CONFIGURATION OPERATION IS NOT ALLOWED DUE TO FORCED RESERVATION

The given software configuration operation is not permitted, because there is a forced reservation on the attempted operation and a new res-ervation is therefore not possible. Forced reservation is made manually using the MML command WXE. Operation execution conditions and reservation situation may be interrogated using MML commands WXI and WXP. You can release the forced reservation using the WXF command.

12921 RESOURCE CANNOT BE RELEASED BECAUSE IT IS NOT FOUND IN RESERVATION DATA

The resource of software configuration administration cannot be released because it cannot be found in the reservation data.

12925 THE CELL RATE REQUESTED CANNOT BE PROVIDED.

The cell rate requested is greater than available cell rate.

12926 TIME SUPERVISION ON READING DISK DIRECTORY

The reading of the disk directory failed, because the time supervision expired.

12927 SET NAME IS NOT UNIQUE

An attempt was made to create a configuration set with duplicate name. Give a unique name for the set.

12928 ALL CONFIGURATION SETS IN USE

Creation of configuration set failed, because the maximum amount of configuration sets have already been created and a new set could therefore not be allocated. Delete one of the existing sets to enable the creation of a new one.

12929 CONFIGURATION SET DOES NOT EXIST

There is no configuration set that has the given name.

12930 OPERATION NOT ALLOWED

Configuration command was rejected because its execution is not per-mitted.

Page 251: DX Error Messages

DN987378Issue 24-0

251

General Error Messages of System DX error messages

Id:0900d8058077e097

12931 RESOURCE DOES NOT EXIST

No resource with the given name and unit type exist.

12932 VALUE IS OUT OF LIMITS

Modification of a resource failed because the given value was not inside the predefined quantity limits of the resource in question.

12933 MEMORY SHORTAGE DURING THE ACTIVATION OF A CONFIGU-RATION SET

Activation of the configuration set was not possible because a memory shortage was detected in some unit type.

12934 ULAPRB IS BUSY

ULAPRB is busy.

12935 INFORMATION DOES NOT EXIST

The searched-for information does not exist.

12936 VIRTUAL SUBSCRIBER FOR INTERNAL USE

Virtual subscriber for internal use.

12937 ANALYSIS RESULT CORRUPTED

The analysis result is corrupted.

12939 SWITCHING OF DISK UPDATING STATE INTERRUPTED

The attempt to switch the state of disk updating has been interrupted by the system, and the state has been reset to as it was before.

12940 DISK UPDATING STATE PREVENTED

The attempt to switch the state of disk updating has been interrupted by the system.

12941 DISK UPDATING STATE IS INCORRECT

Disk updating state is incorrect.

12942 TM SUBSCRIBER DOES NOT EXIST

The searched-for TM subscriber does not exist.

12943 NO ALARMS FOUND IN ALARM HISTORY

There are no alarms in the alarm database BAIDAT.

12944 ALL ALARMS READ FROM THE DATABASE

All active alarms or alarm history have been read from the database BAIDAT.

12945 ALARM DOES NOT EXIST

The alarm or alarms by the given conditions do not exist in the data-base.

12946 PID NUMBER LIMIT REACHED

The maximum number of alarm process instance identifiers for one alarm_number in the alarm database has been reached.

12947 ALARM PID EXISTS

The given process instance identifier already exists in the alarm data-base.

Page 252: DX Error Messages

252 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

12948 ALARM PID DOES NOT EXIST

The searched process instance identifier does not exist in the alarm database.

12949 RECOVERY OF DUCFIL NOT SUCCESSFUL

The recovery of DUCFIL file failed because its state is not correct.

12950 DUCFIL COULD NOT BE OPENED OR INITIALISED

DUCFIL file could not be opened or initialised.

12952 COULD NOT UPDATE DIRECTORY NUMBER DATA

The directory number data could not be updated.

12954 MONITORING: WS_USER HAS NO RIGHTS

Monitoring: Ws_user has no rights.

12956 SYNCHRONISATION IS NOT ALLOWED IN DE45/DF45 (=F, PRI-MESITE) TYPE BTS

Synchronisation is not allowed in a DE45/DF45 type BTS. The user cannot give the value Y to the SYNC parameter when creating an adjacent cell to a DE45/DF45 type BTS.

12958 TM SUBSCRIBER ALREADY EXISTS

A TM subscriber already exists in this exchange.

12959 RECEIVER HAS REQUESTED MODULE DURING LOADING

The receiver has requested a new load module during the loading. This is to say, the load sender and receiver are in different states.

12960 FLOATING TRX NOT ALLOWED TO EXIST IN SITE TYPE MODIFI-CATION

During site type modification, no floating TRXs are allowed to exist. Remove the floating TRX and try again.

12961 E-RACH CHANNEL NOT ALLOWED TO EXIST IN SITE TYPE MODI-FICATION

No E-RACH channels are allowed to exist during site type modification.

12962 ATTACHED MA LIST IS NOT ALLOWED IN SITE TYPE MODIFICA-TION

In site type modification, an attached MA list is not allowed.

12963 RF TEST EQUIPMENT IS NOT ALLOWED TO EXIST IN SITE TYPE MODIFICATION

RF test equipment is not allowed to exist during site type modification.

12964 TOY CLOCK INOPERABLE

TOY clock (Time Of Year clock) is not in operable state.

12965 TOY CLOCK TIME LOST

TOY clock (Time Of Year clock) has stopped.

12966 TOY CLOCK DISABLED

TOY clock (Time Of Year clock) is disabled and the time indicated by it is therefore unreliable.

12967 E-TRX IS NOT ALLOWED TO EXIST IN SITE TYPE MODIFICATION

Page 253: DX Error Messages

DN987378Issue 24-0

253

General Error Messages of System DX error messages

Id:0900d8058077e097

E-TRX is not allowed to exist in site type modification.

12968 RF HOPPING IS NOT ALLOWED IN SITE TYPE MODIFICATION

RF hopping is not allowed in site type modification.

12969 SMSC OR GT ANALYSIS DOES NOT EXIST

There is no SMSC or GT analysis for the new SMSC address.

12970 TOY CLOCK UPDATE FAILED

The updating of TOY clock (Time Of Year clock) has failed.

12971 ERROR WHILE MOVING DATA FROM FALLBACK COPY LOG FILE

An error has occured while moving data from the fallback copy log file to buffer.

12972 ERROR WHILE HANDLING FALLBACK COPY LOG FILE

An error has occured while trying to handle fallback copy log file.

12973 FALLBACK COPY LOG FILE IS INCOMPLETE

Fallback copy log file is incompleted: the last record of log file is cor-rupted.

12974 UNKNOWN RECORD VALUE IN FALLBACK COPY LOG FILE

An unknown record value appeared in the fallback copy log file. The log file is corrupted.

12975 NO FALLBACK COPYING IN PROGRESS

There is no fallback copying in progress.

12976 QUITTING OF FALLBACK COPYING IS IN PROGRESS

Quitting of fallback copying is already in progress.

12977 TRX DOES NOT SUPPORT HALF RATE CHANNELS

The half rate support is not activated.

12978 BAD USERNAME OR PASSWORD

FTP does not accept a connection request from a remote FTP client because the username or password is incorrect.

12979 BAD DIRECTORY NAME

The name of the directory is incorrect.

12980 PXRECE HAS NOT ACKNOWLEDGED UPDATING REQUEST TO SYIPRB

The PXRECE has not acknowledged the updating request of the distri-bution table of the SYIPRB.

12981 BAD FTP PORT VALUE

The value of the PORT command is incorrect.

12982 BAD FTP TYPE VALUE

The value of the FTP type is incorrect.

12983 BAD FTP STRUCTURE VALUE

The value of the FTP structure is incorrect.

12984 BAD FTP MODE VALUE

Page 254: DX Error Messages

254 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The value of the FTP mode is incorrect.

12985 FTP DATA CONNECTION FAILED

The FTP data connection failed.

12986 FTP FILE BUSY

The FTP file is temporarily busy.

12987 FTP FILE NOT FOUND

The requested FTP file does not exist or the path name is incorrect.

12988 FTP DIRECTORY NOT FOUND

The FTP directory does not exist or the path name is incorrect.

12989 BAD FTP FILE NAME

The FTP file name is incorrect.

12990 BAD FTP FILE SIZE

The allocated file size for the file to be written is too small.

12991 NO FTP FILE ACCESS

No FTP file access.

12992 FTP FILE IS UNAVAILABLE

The FTP file is unavailable.

12993 BAD FTP FILE ALLOCATION

The allocation of the FTP file is incorrect.

12994 ROUTE OR CIRCUIT GROUP HAS A TIMER INDEX ATTACHED

Route or circuit group cannot be deleted if there is a timer index attached to it. Remove the timer index first, using the MML command CTR.

12995 ISDN TRX IS NOT ALLOWED TO EXIST IN SITE TYPE MODIFICA-TION

If the destination site type is Nokia 2nd generation, ISDN TRX is not allowed to exist in site type modification.

12996 MAXIMUM NUMBER OF TRX IDS ALREADY IN USE

The maximum number of TRX IDs is already in use.

12997 CREATION OF HAND HAS FAILED IN SYIPRB

The creation of a hand has failed in the SYIPRB probably because of an operating system error.

12998 SYIPRB HAS NO TIME FOR REQUESTED TASK

The SYIPRB is busy. It has no time for the requested task.

12999 PXRECE HAS NOT ACKNOWLEDGED UPDATING REQUEST OF SYIPRB

The PXRECE has not acknowledged the updating request of the distri-bution table made by the SYIPRB. The SYIPRB has cancelled an ongoing switchover.

13000 TRX ID UNKNOWN

Page 255: DX Error Messages

DN987378Issue 24-0

255

General Error Messages of System DX error messages

Id:0900d8058077e097

A configuration mismatch has been found between GUPDAT and Abis signalling program blocks, or a message was corrupt.

13001 RECOVERY PROGRAM BLOCK DOES NOT CONTROL UNIT RESTART

The unit is restarting, and the recovery program block RCXPRO cannot control its loading.

13002 UNIT OVERLOAD

The unit working as the source of loading cannot give loading permis-sion because the unit is overloaded.

13003 LOADING PARAMETERS ARE NOT VALID

The parameters for initial loading and file loading are missing or they are not valid.

13004 CBCH MOBILE ALLOCATION OVERFLOW OR C2 CELL RESELEC-TION ACTIVE IN SYSINFO 4

SYSINFO 4 has no space for the C2 cell reselection parameter because the CBCH mobile allocation list includes too many values.

13005 FREQUENCY VALUE ZERO IN ABIS INTERFACE-INTERNAL ARFCN TABLE

The internal ARFCN table of the Abis interface includes a frequency value zero.

13006 FREQUENCY BAND UNKNOWN

The frequency band was not GSM or DCS.

13007 TOO MANY ARFCN VALUES (RANGE 256)

The creation of range 256 fails because of too many ARFCN values.

13008 TOO MANY ARFCN VALUES (RANGE 512)

The creation of range 512 fails because of too many ARFCN values.

13009 TOO MANY ARFCN VALUES (RANGE 1024)

The creation of range 1024 fails because there are too many ARFCN values.

13010 USE OF THIS RANGE NOT ALLOWED

The use of this range has been barred by UTPFIL.

13011 CELL ALLOCATION IS NOT AVAILABLE

The length of the cell allocation table is zero.

13012 TOO MANY VALUES IN THE CELL ALLOCATION TABLE

The length of the cell allocation table is greater than allowed.

13013 VALUE ZERO IN CELL ALLOCATION TABLE

There is a frequency value zero in the cell allocation table.

13014 INVALID VALUE IN THE CELL ALLOCATION TABLE

There is an invalid ARFCN value in the cell allocation table.

13015 SAME ARFCN VALUE TWICE IN CELL ALLOCATION TABLE

The same ARFCN value occurs twice in the cell allocation table.

Page 256: DX Error Messages

256 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13016 TOO MANY ARFCN VALUES OR TOO BIG DIFFERENCE BETWEEN GREATEST AND SMALLEST VALUE

There is an overflow in the Abis interface-internal ARFCN table.

13017 MOBILE ALLOCATION IS NOT AVAILABLE

The length of the mobile allocation table is zero.

13018 TOO MANY VALUES IN THE MOBILE ALLOCATION TABLE

The length of the mobile allocation table is greater than allowed.

13019 ZERO VALUE IN THE MOBILE ALLOCATION TABLE

There is a frequency value zero in the mobile allocation table.

13020 INVALID VALUE IN THE MOBILE ALLOCATION TABLE

There is an invalid ARFCN value in the mobile allocation table.

13021 SAME ARFCN VALUE TWICE IN MOBILE ALLOCATION TABLE

The same ARFCN value occurs twice in the mobile allocation table.

13022 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO BIG (BM0)

The creation of bit map 0 format fails because the difference between the greatest and the smallest ARFCN value is too big.

13023 TOO MANY ARFCN VALUES (BM0)

The creation of the bit map 0 format fails because of too many ARFCN values.

13024 TOO MANY ARFCN VALUES (VBM)

The creation of variable bit map format fails because of too many ARFCN values.

13025 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO BIG (VBM)

The creation of variable bit map format fails because the difference between the greatest and smallest ARFCN value is too big.

13026 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO BIG (RANGE 256)

The creation of range 256 fails because the difference between the greatest and smallest ARFCN value is too big.

13027 DIFFERENCE BETWEEN GREATEST AND SMALLEST FRE-QUENCY IS TOO BIG (RANGE 512)

The creation of range 512 fails because the difference between the greatest and smallest ARFCN value is too big.

13028 NO SYSTEM INFORMATION ACKNOWLEDGEMENT MESSAGES RECEIVED FROM LAYER 2

SYIPRB has not received system information acknowledgement messages from the layer 2.

13029 WRONG VALUE OF THE PARAMETER NEIGH_CELL_RANGE_LIMITS_PRM_C

Page 257: DX Error Messages

DN987378Issue 24-0

257

General Error Messages of System DX error messages

Id:0900d8058077e097

The value of the neigh_cell_range_limits_prm_c parameter is incorrect. The value must be between 0 and 7.

13030 BTS ID UNKNOWN

A configuration mismatch has been found between GUPDAT and Abis signalling program blocks, or a message was corrupt.

13031 THE SUM OF PERCENTAGE RATES ON REMNANT TRAFFIC DIS-TRIBUTION DIFFERS FROM 100

The sum of percentage rates on remnant traffic distribution of all carrier access codes in use differs from 100. Correct the percantage rates so that the sum total equals 100%.

13032 MISSING PIU TYPE INFO

Correct data on plug-in unit type cannot be read from HW.

13033 MISSING PIU UNIQUE INFO

The unique identification data for the plug-in unit cannot be read from HW.

13034 UNSUPPORTED FTAM SERVICE CLASS

Unsupported FTAM service class. The corresponding FTAM diagnostic code is 2002 and it is an association-related diagnostics notice, defined in ISO 8571-3.

13035 FTP COMMAND NOT SUPPORTED

The FTP command is not supported.

13036 FTP ARGUMENT NOT SUPPORTED

The FTP argument is not supported.

13037 ILLEGAL ADDRESS INFO OF PLUG-IN UNIT IN EQUIPMENT DATABASE

The address information that is given about the plug-in unit in the equip-ment database is incorrect or incompatible with the plug-in unit type.

13038 DISTRIBUTION ABOUT CHANGE IN DATABASE FAILED

The database has been updated, but distribution has failed.

13044 V5.1-MUX SUBSCRIBER

This subscriber is connected to the concentrator via a V5.1-MUX inter-face.

13045 COMMUNICATION ERROR IN DSP PROCESSOR

An error has occurred in the communication between the DSP proces-sor and the processor controlling it.

13046 NO SUCH V5.1-MUX SUBSCRIBER

There is no V5.1-MUX subscriber of the given type in the user port data-base.

13048 EVENT LOG STREAM IS OPEN ON DAT

The given event log stream is open to DAT tape. To delete this event log stream, you must first close it on DAT, using the MML command DLC.

Page 258: DX Error Messages

258 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13049 ANALYSIS RESULT NON-EXISTENT

The analysis result does not exist.

13050 ANALYSIS RESULT EXISTS

The analysis result already exists.

13051 ENTERED DATA NOT IN ENCRYPTED FORM

The entered data (e.g. the cryptographic key) was in clear form although it is expected to be in encrypted form. Encrypt the data and re-enter it.

13052 CHECK SUM OF LOAD MODULE IN LOAD CHAIN IS INCORRECT

The check sum of the load module is incorrect.

13053 MODULE NAME OF LOAD MODULE IN LOAD CHAIN DOES NOT MATCH THE NAME IN BOOLIS

The module name of the load module does not match the name in BOOLIS. The order of the modules is different in the memory and in BOOLIS.

13054 HIGH TAG OF LOAD MODULE IN LOAD CHAIN IS INCORRECT

The high tag of the load module is incorrect.

13055 LOW TAG OF LOAD MODULE IN LOAD CHAIN IS INCORRECT

The low tag of the load module is incorrect.

13056 LINK FIELD OF LOAD MODULE IN LOAD CHAIN IS INCORRECT

The link field of the load module is incorrect.

13057 ISDN O&M LINK IS NOT ALLOWED TO EXIST IN SITE TYPE MODI-FICATION

The modification of site type does not allow the ISDN O&M link to exist.

13058 FTP OPERATION EXECUTED PARTLY OK

The execution of the FTP operation has been partly successful.

13059 FTP FILE HAS BEEN READ

The FTP file has been read.

13065 FTP DATA CONNECTION CLOSED

The FTP data connection failed because the FTP client closed the con-nection.

13066 FTP LOCAL FAILURE

The FTP command failed because of a local failure in the server process. The failure probably appeared from the disk system. Check the logs of the SFTPAT process.

13067 UNIT STATE HAS TO BE WO BECAUSE IT HAS EXCHANGE TERMI-NALS TO SUPERVISE

The working state of the unit has to be active (WO) because it has exchange terminals to supervise.

13068 UNIT STATE HAS TO BE WO BECAUSE IT HAS PREPROSESSORS TO SUPERVISE

The working state of the unit has to be active (WO) because it super-vises preprosessor(s) behind an LAPD-channel.

Page 259: DX Error Messages

DN987378Issue 24-0

259

General Error Messages of System DX error messages

Id:0900d8058077e097

13069 UNIT STATE HAS TO BE SP BECAUSE IT HAS NO PREPROS-ESSORS TO SUPERVISE

The working state of the unit has to be passive (SP) because it has no preprosessors behind an LAPD-channel or other resources to super-vise.

13070 UNIT STATE HAS TO BE WO BECAUSE IT HAS CCS7 SIGNALLING LINKS

The working state of the unit has to be active (WO) because it has CCS7 signalling links.

13071 UNIT STATE HAS TO BE SP BECAUSE IT HAS NO CCS7 SIGNAL-LING LINKS

The working state of the unit has to be passive (SP) because it has no CCS7 signalling links or resources to be supervised.

13072 UNIT STATE HAS TO BE ACTIVE (WO)

The state of the unit must be active (WO). If you need to force another working state for the unit, use the MML command USC, its parameter FCD.

13073 UNIT STATE HAS TO BE PASSIVE (SP)

The state of the unit has to be passive (SP). If you need to force another working state for the unit, use the MML command USC, its parameter FCD.

13074 THE LAST (N+1) REPLACEABLE REDUNDANT SPARE UNIT CANNOT BE ACTIVATED

The unit cannot be activated, otherwise no redundancy remains to provide fault tolerance.

13076 INCORRECT PROTOCOL USED

An incorrect protocol has been used. It is eg. possible that you have tried to use locally (in your own unit) a remote protocol that is meant to be used from another unit.

13077 NO REPLY FROM SIGNALLING

Central Memory (CM) has sent a request to signalling but there was no reply within the given time limit. Try again.

13079 PACKAGE NAME IS ALREADY IN USE

A package named like this has already been created (in the SOMAFI file).

13080 BU-PACKAGE IS MISSING IN FALLBACK COPY

Fallback copying is not possible because a BU-package is missing.

13081 UNIT STATE HAS TO BE SP BECAUSE IT HAS NO EXCHANGE TER-MINALS TO SUPERVISE

The working state of the unit has to be passive (SP) because it has no exchange terminals or other resources to supervise.

13082 PACKAGE IDENTIFIERS DO NOT MATCH BETWEEN BU- AND FB-PACKAGE

Page 260: DX Error Messages

260 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The execution of the ARCHIVE or DATA fallback copy is not possible because package identifiers do not match between the BU- and FB-package.

13083 NOT ENOUGH DISK SPACE

There is not enough free disk space to execute fallback copy.

13084 GIVEN OPTIONAL DIRECTORY NAME IS NOT ALLOWED

The name given for the optional directory is not allowed, because the same name is already in use. Either it has been given before or the name is reserved by the system (ASWDIR, BLCODE, LFILES, MMDIRE or SCMANA).

13085 FALLBACK COPY IS NOT POSSIBLE: FB-PACKAGE MISSING

Fallback copying is not possible because FB-package is missing.

13086 INCORRECT WORKING STATE ON DISK

Operation is not possible because the working state of the disk is incor-rect: the working state has to be WO-BU.

13087 INCORRECT WORKING STATE OF THE DISK UNIT

Fallback copying is not possible because the state of the disk unit is incorrect: the working state has to be SE-NH or WO-EX.

13088 FALLBACK COPYING IS NOT POSSIBLE BECAUSE OF MISSING SUBDIRECTORY

Fallback copying (of DATA or ARCHIVE) is not possible because the subdirectory given in the BU-package is missing in the FB-package.

13089 FALLBACK COPY IS NOT POSSIBLE BECAUSE FB-PACKAGE IS DEFAULT PACKAGE

Fallback copying is not possible because the FB-package is the default package.

13091 PACKAGE ALREADY EXISTS IN DIRECTORY

Fallback copying is not possible to the given directory, because a package has already been created for the directory.

13093 INVALID UNIT TYPE

Type of unit is not correct for the operation.

13094 SUBSCRIBER HAS NOT THE GIVEN HLR ADDRESS

The HLR address of the subscriber in the database is different from the HLR address given in the search criteria.

13097 DISTRIBUTION NOT DONE

File or record distribution was not done.

13098 DEFAULT VALUE IS MISSING

Default value is missing.

13100 ENHANCED RAPID FIELD DROP OPTION IS NOT IN USE IN BSC

The option Enhanced Rapid Field Drop is not in use in BSC. The basic idea of this feature is to detect the Deep Dropping Edge of the serving cell signal and perform a handover to the appropriate adjacent cell.

Page 261: DX Error Messages

DN987378Issue 24-0

261

General Error Messages of System DX error messages

Id:0900d8058077e097

13101 ICE OPTION IS NOT IN USE IN BSC

The basic idea of this feature is to provide handover support for BTSs having transceivers of different transmitting power. This error code indi-cates that the option is not in use.

13102 APPLICATION DOES NOT RESPOND TO EVENT LOG

Application does not respond to event log. This error can occur for example in recovery, when event logs are run and the application does not acknoledge recovered data.

13103 REFERENCE HOME AREA DOES NOT EXIST

The reference home area cannot be found from the home area files.

13104 LAST LOCATION AREA IN HOME AREA

The location area is the last one in the home area.

13105 HOME AREA DOES NOT EXIST

The home area cannot be found from the home area files.

13106 HOME AREA ALREADY EXISTS

The home area already exists in the home area files.

13107 HOME AREA CONTAINS SUBSCRIBERS

The home area contains subscribers.

13108 LOCATION AREA DOES NOT CONTAIN BASE TRANSCEIVER STATIONS

The location area does not contain base transceiver stations.

13109 VIRTUAL MACHINE NUMBER NON-EXISTENT

The Virtual Answer Machine number is not in use.

13111 OPTION HSCSD NOT IN USE IN BSC

The High Speed Circuit Switched Data (HSCSD) option is not in use in BSC. The HSCSD offers a remarkable increase in the data rate over the GSM system.

13112 DYNAMIC HOT SPOT OPTION IS NOT IN USE IN BSC

This feature is designed to control traffic in a frequency hopping radio network on the basis of the interference and hence achieve the higher radio network capacity. Dynamic Hot Spot -error code indicates that the option is not in use.

13113 MF FUNCTION STATISTICAL COUNTER NOT FOUND SEARCH-ING BY SEQUENCE NUMBER

The statistical counter of the MF function is not found when searched using the sequence number of the MF function.

13114 MF FUNCTION STATISTICAL COUNTER NOT FOUND SEARCH-ING BY PIU FUNCTION

The statistical counter of the MF function cannot be found when the PIU function is given as the search key.

13115 PROCESSING IN APPLICATION ALARM HANDLER HAS FAILED

Page 262: DX Error Messages

262 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The application alarm handler failed to process the task (e.g. saving alarm parameters or cancelling or blocking an alarm).

13116 OPTIONAL FEATURES FORMING THIS COMMAND GROUP ARE NOT INCLUDED IN DELIVERY

This command group consists of optional features which are not included in this delivery.

13117 LOCATION AREA NOT FOUND OR DOES NOT CONTAIN BASE TRANSCEIVER STATIONS

Location area/areas not found in LAFILE, or location area/areas do not contain any BTSs.

13118 LOAD LIST IS NOT DEFINED

The load list has not been defined.

13119 SUPER-REUSE FREQUENCY GROUP OF TRX IS INCORRECT

When frequency hopping and Intelligent Underlay Overlay are in use, all the unlocked TRXs of the layer must belong to the same super-reuse frequency group.

13120 ONE OR MORE ILLEGAL CHANNEL TYPES

There was one or more channel types other than COMB, MAIN, SDCCH, TCHF, BCCH_CBCCH, SDCCH_CBCH, NOT_IN_USE or E_RACH.

13121 ILLEGAL BCCH LOCATION

BCCH was in a time slot other than RTSL 0.

13122 TCSM NOT FOUND

The TCSM is not found.

13123 ILLEGAL E-RACH LOCATION

E-RACH was in a time slot other than RTSL 0.

13124 TOO MANY BCCH TRXS

Only one broadcast control channel TRX is allowed in one cell.

13125 ILLEGAL SDCCH-CBCH LOCATION

SDCCH-CBCH can only be located in a BCCH TRX.

13126 SDCCH WAS NOT FOUND IN BCCH TRX

A BCCH TRX must contain an SDCCH.

13127 TOO MANY SDCCH SUBCHANNELS

There can be only 12 SDCCH subchannels in one TRX.

13128 TOO MANY CBCH CHANNELS

Only one CBCH channel is allowed in one TRX.

13129 ILLEGAL TIME SLOT FOR SDCCH-CBCH

SDCCH-CBCH can be in time slots 1 - 3.

13130 ILLEGAL SITE TYPE FOR E-RACH

This site type cannot have an E-RACH.

Page 263: DX Error Messages

DN987378Issue 24-0

263

General Error Messages of System DX error messages

Id:0900d8058077e097

13131 ILLEGAL BCCH DEFINITION: E-TRX AND S-TRX CANNOT CONTAIN BCCH

ILLEGAL BCCH DEFINITION: E-TRX AND S-TRX CANNOT CONTAIN BCCH

13132 ILLEGAL E-RACH LOCATION: IT MUST BE IN E-TRX OR S-TRX

ILLEGAL E-RACH LOCATION: IT MUST BE IN E-TRX OR S-TRX

13133 WRONG NUMBER OF E-RACH CHANNELS IN E-TRX OR S-TRX

WRONG NUMBER OF E-RACH CHANNELS IN E-TRX OR S-TRX

13134 WHEN E-TRX OR S-TRX IS USED, TIMESLOT 1 OF BCCH TRX MUST BE OF TYPE NOTUSED

WHEN E-TRX OR S-TRX IS USED, TIMESLOT 1 OF BCCH TRX MUST BE OF TYPE NOTUSED

13135 INITIALSWVERSION IS NOT ONLY ATTRIBUTE TO BE ASKED

The INITIALSWVERSION and other attributes are asked at the same time.

13136 3-DIGIT MOBILE NETWORK CODE OPTION IS NOT IN USE IN BSC

The 3-Digit Mobile Network Code feature is based on ANSI specifica-tions. If the option is not activated, MNC is handled with 2 digits.

13137 INTEGRITY CHECKING IN MEMORY IS NOT ALLOWED

Integrity checking in memory is not allowed for the requested database.

13138 INTEGRITY CHECKING ON DISK IS NOT ALLOWED

Integrity checking on disk is not allowed for the requested database.

13139 ALL SDCCH HANDS OF ABIPRB ARE TEMPORARILY IN USE

All SDCCH hands of the ABIPRB are temporarily in use - the TRX con-figuration command can be repeated after a while.

13140 MAXIMUM NUMBER OF LOCATION AREAS IN HOME AREA EXCEEDED

The maximum number of location areas (96) in home area exceeded in the creation of a new home area.

13141 DATA LENGTH IN MID DATA MESSAGE WAS INVALID

The data length given in the mid_data message was invalid.

13142 FREQUENCY HOPPING FOR INTELLIGENT UNDERLAY OVERLAY OPTION IS NOT IN USE IN BSC

The Frequency Hopping for Intelligent Underlay Overlay is an optional feature designed to allow the operator to reuse frequencies more inten-sively and hence achieve a higher radio network capacity. This error code indicates that the feature is not in use.

13143 BSC OBJECT NOT FOUND IN RADIO NETWORK DATABASE

The access node has not been created into the radio network database. No other objects can created before the BSC object has been created.

13144 BCF OBJECT NOT FOUND IN RADIO NETWORK DATABASE

Page 264: DX Error Messages

264 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The Base Control Function object has not been created into the data-base. There must be an existing BCF under which a base station object can be created.

13145 TOO MANY INTERFERING CELLS DEFINED TO FREQUENCY GROUP

Too many interfering cells have been defined to the frequency group. The frequency group is defined by the parameter FRT of the TRX so that all TRXs that have the same FRT belong to the same frequency group.

13148 BTS NOT FOUND FROM RADIO NETWORK DATABASE

The base station has not been created into the radio network database. There must be an existing BTS under which a transceiver, a frequency hopping system, or an adjacent cell object can be created.

13149 TRX NOT FOUND IN RADIO NETWORK DATABASE

The transceiver has not been created into the radio network database. There must be an existing TRX under which a radio time slot can be created.

13150 RADIO TSL NOT FOUND IN RADIO NETWORK DATABASE

The radio time slot has not been created into the radio network data-base.

13151 HOPPING SYSTEM NOT FOUND IN RADIO NETWORK DATABASE

The Frequency Hopping System has not been created into the radio network database. There must be an existing FHS into which a hopping radio time slot can be connected.

13152 ADJACENT CELL WAS NOT FOUND IN RADIO NETWORK DATABASE

The adjacent cell has not been created into the radio network database.

13153 MA LIST NOT FOUND IN RADIO NETWORK DATABASE

The MA list must be created before any BTS can be attached to it.

13154 WSU IS FULL, NO MORE TRANSCEIVERS CAN BE CREATED IN SAME UNIT

The maximum number of transceivers allowed in the signalling unit has been reached. A D-channel in another WSU should be used.

13155 ALL CPUS MUST BE CP4HX IF MORE THAN 16 TRXS IN WSU

All CPUs must be of type CP4HX if there are more than 16 TRXs in WSU.

13156 GSWB MUST BE INSTALLED WHEN MORE THAN 16 TRXS IN WSU

GSWB must be installed when there are more than 16 TRXs in one WSU.

13157 TOO FEW AS7-U PLUG-IN UNITS WHEN MORE THAN 16 TRXS IN WSU

There are only three AS7-U plug-in units in all WSUs when there are more than 16 TRXs in one WSU.

Page 265: DX Error Messages

DN987378Issue 24-0

265

General Error Messages of System DX error messages

Id:0900d8058077e097

13158 TOO FEW WSUS IN WO-EX STATE WHEN MORE THAN 16 TRXS IN WSU

Eight WSUs in WO-EX state when there are more than 16 TRXs in one WSU.

13159 TOO MANY TCHS IN ONE WSU

Maximum number of traffic channels exceeded in one WSU.

13160 THERE ARE TOO MANY BCFS IN ONE WSU

When creating a BCF (site type B or D), or when creating a TRX (site type F), or when modifying the O&M-link, it became evident that there will be too many BCFs in one WSU.

13161 MAXIMUM TX POWER OF CELL TOO HIGH DUE TO ATTENUATED CHANNELS GSM800

If the frequency band used is GSM800 band, the two channels next to the edge channels of the block must not be used with the maximum transmission power. The FCC, the local regulator in the USA, has set these emission limits for GSM800 band equipments to ensure that an operator on a certain band does not cause disturbance to another operator on adjacent bands.

13162 INITIAL BTS BUILD IS NOT FOUND

The initial build of the BTS generation is not found.

13163 BCF BUILD IS INITIAL PACKAGE

The BCF build is defined as the initial build of the BTS generation.

13167 POSIX INTERFACE ERROR

The call through POSIX subsystem has failed due to faulty parameters, wrong call sequence or an internal error in the subsystem.

13170 EXACTLY SAME BCF HW DATABASE ALREADY CREATED

A BCF HW database creation is requested to a database that has already been created with the same file name and checksum.

13171 FREQUENCY NOT ALLOWED TO BE ZERO

The value zero for frequency is not allowed.

13172 INTERFERING CELL LAC-CI NOT UNIQUE WITHIN TRX

LAC-CIs of interfering cells within one TRX must be unique.

13173 SIMULTANEOUS BB AND RF HOPPING IS NOT ALLOWED UNDER BTS

The operation was rejected because there is simultaneously defined BB (baseband) and RF (radio frequency) hopping in the BTS.

13174 ALARM FILE FULL OF ACTIVE ALARMS

The alarm file in the alarm database is full of active alarms.

13175 ALARM ALREADY EXISTS

The alarm occurrence already exists in the alarm database.

13176 UPPER LEVEL ALARM HISTORY LINK FAILED

Upper level alarm history link is discontinuous.

Page 266: DX Error Messages

266 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13178 OPERATING INSTRUCTION ADDITION FAILED

Addition of an operating instruction to the database has failed.

13179 OBJECT ADDITION FAILED

Addition of an object to the database failed.

13180 TEXT DOES NOT EXIST

No text with the given terms exists in the database.

13181 OPERATING INSTRUCTION OR FIXED TEXT EXISTS

An operating instruction or a fixed text exists.

13182 OBJECT JOINED TO ALARM

An object is joined to the alarm to be removed.

13183 OPERATING INSTRUCTION ALREADY EXISTS

An operating instruction by the given terms already exists in the data-base.

13192 OBJECT IS LOWEST

The given object is the lowest one.

13194 TOO MANY UNITS FOUND

DUFLIB routines return this error code when the number of units found exceeds the limit the caller has specified.

13195 NO UNITS FOUND

DUFLIB routines return this error code when no units with given param-eters could be found.

13196 OPERATING INSTRUCTION NOT FOUND

An operating instruction by the given terms does not exist in the data-base.

13201 PASSWORD EXPIRED

User password has expired.

13202 PASSWORD IS GOING TO EXPIRE

User password is going to expire in specified time.

13204 ADDITION FAILED

The addition to the database failed.

13206 LAST ALARM RECEIVED

The last active_alarm_inquiry_ack_s message from ULAPRB to ARNOLD has a status field the value of which is the all_alarm_read_ec error code.

13207 REQUESTED TASK WAS ONLY PARTIALLY COMPLETED

The requested task was completed only partially, due to internal resource limitations.

13211 MISSING ENVIRONMENT

This error text concerns only the platform and indicates that there is no application level.

13212 MASTER OBJECT IS BLOCKED

Page 267: DX Error Messages

DN987378Issue 24-0

267

General Error Messages of System DX error messages

Id:0900d8058077e097

The blocking of the child is attempted, but its master object has already been blocked.

13213 OBJECT ALREADY BLOCKED

Returned when the object to be blocked has already been blocked.

13214 UNIT STATE MUST BE WO BECAUSE IT HAS LAPD SIGNALLING LINKS TO SUPERVISE

The working state of the unit must be active (WO) because it has LAPD signalling links to supervise.

13215 UNIT STATE MUST BE SP BECAUSE IT HAS NO LAPD SIGNALLING LINKS TO SUPERVISE

The working state of the unit must be passive (SP) because it has no LAPD signalling links or other resources to supervise.

13216 NOT ENOUGH MEMORY TO COMPLETE THE OPERATION

There is not enough memory to complete the operation. Error code is received when lack of memory is observed outside operating system kernel by system software program or the application. This may occur for example when the amount of free memory is checked before file cre-ation.

13217 OBJECT IS NOT BLOCKED

The object whose unblocking is attempted is not blocked.

13218 SCHEDULED BLOCK ALREADY EXISTS

The blocking which has time parameters already exists. The function is not accepted.

13221 OPTION FREQUENCY HOPPING FOR IUO IS NOT ACTIVE IN BSC

If a cell has super-reuse TRXs and one or the other layer is hopping, the option Frequency Hopping for Intelligent Underlay Overlay must be active in the BSC.

13222 ILLEGAL WORKING STATE

The circuit(s) cannot be changed into the given working state.

13223 NO REPLY FROM CM

There is no reply from Central Memory (CM) to the request to change the working state of the circuit(s).

13224 MATCHING EVENTS NOT FOUND

Inquired events were not found.

13225 FCEFIL FILE FULL

New file size changes cannot be started because FCEFIL file is full.

13226 FCEFIL ALREADY HAS KEY VALUE

Key value cannot be added to FCEFIL file because it already has a key value.

13227 CHARGING MODIFICATION NOT FOUND

Given charging modification was not found.

13228 CHARGING MODIFICATION RESULT NOT FOUND

Page 268: DX Error Messages

268 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Given charging modification result was not found.

13229 CHARGING MODIFICATION RESULT IN USE

The given charging modification result is in use (attached to charging modification).

13230 CHARGING MODIFICATION IN USE

The given charging modification is in use (attached to charging case).

13231 CHARGING MODIFICATION RESULT EXISTS ALREADY

Given charging modification result exists already.

13232 CHARGING MODIFICATION IDENTIFICATION INFORMATION CON-TRADICTORY

Given charging modification identification information mutually contra-dictory.

13233 CHARGING MODIFICATION RESULT IDENTIFICATION INFORMA-TION CONTRADICTORY

Given charging modification result identification information is mutually contradictory.

13234 CHARGING MODIFICATION ATTRIBUTE COMBINATION DOES NOT EXIST

Given combination of charging modification attributes does not exist.

13235 CHARGING MODIFICATION DOES NOT CONTAIN ALL GIVEN ATTRIBUTES

The charging modification has been given attributes that do not belong to the charging modification in question.

13236 CHARGING MODIFICATION ATTRIBUTES IN WRONG ORDER

The charging modification attributes are given in wrong order.

13237 CHARGING MODIFICATION ATTRIBUTE VALUE EXISTS ALREADY

Given value of charging modification attribute exists already.

13238 CHARGING MODIFICATION ATTRIBUTE VALUES NOT FOUND

Given values of charging modification attribute were not found.

13239 CHARGING MODIFICATION ATTRIBUTE VALUE UNKNOWN

Given value of charging modification attribute is unknown.

13240 TEST SIDE OF CHARGING MODIFICATION EMPTY

The test side of charging modification is empty.

13241 ALARM UPLOAD PERFORMED

The NMS has performed an alarm upload.

13242 BASIC SERVICE INCOMPATIBILITY

The basic services are incompatible.

13243 VARIANT UNKNOWN AT REMOTE END

This error code indicates that the reason for rejecting the reprovisioning request, or the switch_over_to_new_variant request in the V5 interface, is an unknown variant.

Page 269: DX Error Messages

DN987378Issue 24-0

269

General Error Messages of System DX error messages

Id:0900d8058077e097

13244 VARIANT KNOWN, NOT READY AT REMOTE END

This error code indicates that the reason for rejecting the reprovisioning request, or the switch_over_to_new_variant request in the V5 interface, is a known variant which is not ready for the requested operation.

13245 REPROVISIONING IN PROGRESS AT REMOTE END

The reason for the rejection of the reprovisioning request or the switch_over_to_new_variant request in the V5 interface is that reprovi-sioning is already in progress.

13246 NO RESPONSE FROM NETWORK ELEMENT LEVEL ALARM SYSTEM

Network element level alarm system (program block ULAPRB) does not respond.

13247 NO ANSWER FROM REMOTE END

The remote end does not respond to a reprovisioning request in the V5 interface.

13253 INTELLIGENT NETWORK SUBSCRIBER

The subscriber type is Intelligent Network Subscriber (INS).

13254 INTELLIGENT NETWORK SUBSCRIBER DOES NOT EXIST

The searched-for Intelligent Network Subscriber (INS) does not exist.

13258 INTELLIGENT NETWORK SUBSCRIBER (INS) ALREADY EXISTS

The Intelligent Network Subscriber (INS) already exists.

13259 USAGE OF DATA DICTIONARY NOT INITIALIZED CORRECTLY

Usage of data dictionary has not been initialized at all or the initialization is incorrect.

13260 TOO MANY SUBSCRIBERS FOR THIS OPERATION

The source data contains too many subscribers for this operation. There is not enough e.g. free RAM, disk or database space available.

13261 OPTION FLEXIBLE MAIO MANAGEMENT IS NOT IN USE IN BSC

The Flexible MAIO Management feature is not supported in the BSC.

13262 TASK NOT ALLOWED AT THE MOMENT

The task is not allowed at the moment because the same or some other task close to this one is under execution by the service provider. Try again later.

13263 REPORT FORMING SERVICE DOES NOT HAVE RESOURCES TO FORM REPORT

Report forming service cannot reserve the resources needed in forming a report from RFMLIB library and cannot form the report.

13265 CHANGE DELIVERY ALREADY INSTALLED IN THIS PACKAGE

A change delivery has already been installed in this package. Installing of new change deliveries is possible only after removing already installed change deliveries (WND). It is also possible to take a change delivery package into use and install the desired change deliveries in that.

Page 270: DX Error Messages

270 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13266 READING OF CFLIST FAILED

Error occured when reading CFLIST file.

13267 TRIED TO INSTALL SAME CHANGE DELIVERY MORE THAN ONCE

The same change delivery has been attempted to install more than once in one install command. The same change delivery can only be installed once.

13270 NO CHANGE DELIVERIES TO BE REMOVED

This software package does not contain change deliveries that could be removed. Change deliveries have not been installed or they have alreadybeen removed.

13271 CHANGE DELIVERY IN WRONG STATE

Execution of operation is not allowed because change deliveries are in wrong states.

13272 ERROR WHILE COMMUNICATING WITH SW2ADM PROGRAM BLOCK

SW2ADM program block does not respond or the message that is received contains an error code.

13273 ERROR WHILE COMMUNICATING WITH CPYMAN PROGRAM BLOCK

CPYMAN program block does not respond or the message that is received contains an error code.

13274 UNKNOWN RECORD TYPE

Error detected when trying to handle a file. The file contains an unknown record type.

13275 FUNCTION IS NOT SUPPORTED

PCI hardware related functions return this value when called in non-PCI hardware environment. Certain functions return this value even in PCI hardware. These functions are part of "standard" PCI service interface but have no meaningful implementation in DX200 environment.

13276 INVALID PCI VENDOR ID

A PBMLIB service was called with an incorrect PCI vendor id (i.e. value FFFFh).

13277 PCI DEVICE NOT FOUND

A specific PCI device was searched for but was not found. It was not found because it does not exist or because it has not been configured.

13278 INVALID PCI CONFIGURATION REGISTER NUMBER

Reading and writing to a PCI configuration register has been attempted with a wrong register number. The allowed range is 0-255 for bytes, 0,2,...,254 for words and 0,4,...,252 for dwords.

13279 INDEX IS OUT OF RANGE

The search for nth instance of a PCI device, PCI resource or PCI inter-rupt line has failed because the specified instance does not exist.

13280 INTERRUPT LINE DOES NOT EXIST

Page 271: DX Error Messages

DN987378Issue 24-0

271

General Error Messages of System DX error messages

Id:0900d8058077e097

The device does not have an interrupt line.

13281 RAN OUT OF I/O SPACE

There is not enough free I/O space left in order to successfully accom-plish PCI bus configuration.

13282 OUT OF MEMORY SPACE

There is not enough free memory space left in order to successfully accomplish PCI bus configuration.

13283 PCI DEVICE IS ALREADY IN THE DEVICE MAP

An attempt to add a PCI device in the device map has failed because the specified device is already in the map.

13284 PCI MAP IS FULL

PCI device or resource map is full. A new device or resource cannot be added.

13285 INVALID BAR REGISTER NUMBER

An incorrect PCI bar register number has been used.

13286 PBMLIB: INVALID COMPUTER ADDRESS

PBMLIB library routine has been called with invalid computer address.

13287 COMMUNICATION FAILURE WITH PBMLIB

Communication between PBMLIB and PBLPRB program blocks has failed.

13290 OBJECT IS LOCKED FOR MML USE

The Q3 object is locked for MML use.

13291 ZERO IS NOT ALLOWED CELL RANGE FOR EXTENDED CELL

The cell range is 0 (zero) although the cell has extended-range TRXs. Give the cell range a new value (other than zero) in the case that the cell has extended TRXs.

13292 THE SPECIFIED BASE IS NOT USED

The specified device does not use the specified base address register.

13293 O&M LINK FAILURE. BCCH TRANSMISSION MAY BE ACTIVE

Block the link of the broadcast channel of the cell.

13294 CARTRIDGE CODE NOT AVAILABLE

The code for cartridge type cannot be obtained by reading I/O ports.

13295 UNKNOWN CHARGING MODIFICATION RESULT

The given charging modification result is unknown.

13296 ERROR IN WRITING INTO HIFILE FILE

Writing to the hifile file has failed.

13297 FILE NOT LOCKED BY USER

The file is not locked by user.

13298 LOCK TYPE IS ILLEGAL

User has given illegal lock type.

13299 NON-EXISTENT OBJECT

Page 272: DX Error Messages

272 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The object in question is undefined in the (application-level) alarm system.

13300 DATA VERIFICATION ON TAPE HAS FAILED

Data verification has found erroneous data from tape media.

13301 TAPE VERIFY ALREADY INITIALIZED

Tape verification initialization request is received even if it has already been done.

13302 TAPE VERIFY NOT INITIALIZED

Tape verification is not initialized when verify data on tape request is sent.

13303 ALARM DATABASE UPDATE FAILED DURING OBJECT RESET

Updating of the alarm database failed after the successful object reset.

13304 COPY PHASE ALREADY OVER

Copy phase is already over when copy interrupt request is received.

13306 V5 INTERFACE IS FULL

The V5 interface is full.

13310 TIME PASSED

Time is passed.

13311 CHARGING MODIFICATION ANALYSIS CHAIN BROKEN

Chain of attributes of charging modification is broken.

13312 ILLEGAL PERCENTAGE VALUE FOR CHARGING MODIFICATION

There is an illegal percentage value for charging modification (too big).

13314 THE SSI IS ALREADY IN USE BY A G4WIF CONNECTION

The SSI in question is already reserved for identification of a G4WIF connection.

13315 IF BB HOPPING BCCH TRX IS SUPER-TRX (FRT OTHER THAN 0), ALL TRXS IN BTS MUST HAVE SAME FRT

If the cell is baseband hopping on the underlay level and its BCCH-TRX is a super-TRX (FRT other than 0), all the other TRXs in the cell must also be super-TRXs and have the same FRT as the BCCH-TRX.

13316 CHOSEN INTEGRITY CHECK CAN NOT BE DONE ON THIS DATABASE

The integrity rule or the target (COMP_REL) chosen cannot be checked on the given database. Availability of some of the rules or target depends on the TDL compiler version used in the pac of the database manager.

13317 GIVEN INTEGRITY RULE CAN NOT BE CHECKED ON THIS DATABASE YET

The given rule cannot be checked on the chosen database yet. The implementation of the rule depends on the version of the TDL compiler used in the pac of the database manager.

13318 POOL DOES NOT EXIST

Page 273: DX Error Messages

DN987378Issue 24-0

273

General Error Messages of System DX error messages

Id:0900d8058077e097

The pool does not exist.

13319 RESTART STOPPED BY RECOVERY

Recovery has stopped unit restart.

13320 STARTUP OF THE FAMILY IS INCOMPLETE, ANOTHER STARTUP MESSAGE IS REQUIRED

This error code indicates that the startup of the family is not yet com-plete, and that another startup message is required. A warmed TNSDL application, or actually its translator-specific portion, inserts this error code to the startup_ack_s message it sends as a response to the first startup_s message received by the master process.

13321 REQUESTED SERVICE WAS NOT ACTIVATED

requested service cannot be activated due to the lack of service param-eters

13322 SERVICE IS IN ACTIVE STATE

Service parameters cannot be modified due to the activation status of service

13323 GENERAL VIRTUAL SUBSCRIBER ALREADY EXISTS

A general virtual subscriber already exists.

13325 GENERAL VIRTUAL SUBSCRIBER

General virtual subscriber.

13326 GENERAL VIRTUAL SUBSCRIBER DOES NOT EXIST

The general virtual subscriber does not exist.

13327 NUMBER MODIFIED DUE TO NUMBER PORTABILITY SERVICE

This dx_cause is used when a number is modified by NP service and it needs to be reanalyzed again at EOS or EOS attribute analysis.

13328 UNTERMINATED CALL TO A PORTED NUMBER

This dx_cause is sent to SSO by CC to generate ANSI ISUP REL cause 26 "Misrouted call to a ported number".

13329 THE GIVEN EXCHANGE NOT FOUND

the given exchange not found

13330 ILLEGAL PIU TYPE FROM IDENTIFY CIRCUIT OF A PLUG-IN UNIT IN DMC COMPUTER

The PIU type in the DMC computer is not the same as defined for it in the equipment database. The plug-in unit, the computer carthridge or a CPU unit may be broken. The error can also be caused by erroneous data about the PIU in the equipment database or that the PIU is incor-rectly located in the carthridge (i.e. the PIU is not on the track defined in equipment database).

13331 ILLEGAL TRACK NUMBER FROM IDENTIFY CIRCUIT OF A PLUG-IN UNIT IN DMC COMPUTER

The track number in DMC computer is not the same as defined for it in the equipment database. The plug-in unit, the computer carthridge or the CPU unit may be broken. The error can also be caused by erroneour

Page 274: DX Error Messages

274 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

data about the PIU in the equipment database or that the PIU is incor-rectly located in the carthridge (i.e. the PIU is not on the track defined in equipment database).

13332 FUSE ALARM FROM IDENTIFY CIRCUIT OF A PLUG-IN UNIT IN DMC COMPUTER

There is a fuse alarm in the indentify circuit of a plug-in unit in a DMC computer. The cause is most probably a blown +5 V or - 5 V fuse in the PIU or all the interchangeable bridge connetions are unconnected. The error can also be caused by a broken PIU, carthrigde or CPU unit.

13333 UNKNOWN INTERCHANGEABILITY FROM IDENTIFY CIRCUIT OF A PLUG-IN UNIT IN DMC COMPUTER

The software cannot identify the interchangability of the PIU in DMC computer. Typically, the cause are erroneous interchangeability bridge connetions or the fact that the software does not support interchange-ability. The error can also be caused by a broken PIU, carthrigde or CPU unit.

13334 UNKNOWN VARIANT FROM IDENTIFY CIRCUIT OF A PLUG-IN UNIT IN DMC COMPUTER

The software cannot identify the plug-in unit variant. Typically, the cuase for the error is that the software does not support that variant. The error can also be caused by a broken PIU, carthrigde or CPU unit.

13335 THE CURSOR GIVEN TO THE DDILIB LIBRARY IS INCORRECT

The cursor used for selecting data with the routines in the DDILIB library is incorrect.

13336 DATA DICTIONARY OF THE DATABASE IS INCONSISTENT

The data dictionary of the database cannot be used in this inquiry because parts of data are missing or inconsistent.

13339 BITRATES OF COMBI LINKS DO NOT MATCH IN AUTOCONFIG-URED TRX CREATION

In the autoconfigured TRX creation the bitrates of BCF O&M link and TRX Telecom link must be defined equal.

13340 COMBI LINK CAN BE CREATED ONLY TO FIRST TRX IN AUTOCON-FIGURED TRX CREATION

In the autoconfigured TRX creation the combi link can be defined only for the first TRX.

13341 ULAPRB HAS NOT RECEIVED UPLOAD REQUEST

ULAPRB has not received request to start upload scenario

13342 OPTION ABIS AUTOCONFIGURATION NOT IN USE IN BSC.

BSC support for autoconfiguration is an optional feature.

13343 THE TARGET DXT EXISTS ALREADY

The target DXT already exists in routing table.

13348 BSC IS FULL

Another BTS cannot be added to the BSC.

13349 BTS-BSC RELATION IS NOT DEFINED

Page 275: DX Error Messages

DN987378Issue 24-0

275

General Error Messages of System DX error messages

Id:0900d8058077e097

The BTS is not under a BSC.

13350 CI ALREADY EXISTS IN LOCATION AREA

The given cell identity already exists in the location area.

13351 THERE ARE TOO MANY BSCS UNDER LOCATION AREA

Too many BSCs exist in the location area.

13352 INVALID NEIGHBOUR DEFINITION

The ID of the neighbour is the same as the ID of the object.

13353 MOBILE COUNTRY CODE OR MOBILE NETWORK CODE IS NOT MODIFIED

The mobile country code or mobile network code is not modified.

13354 THERE IS NO BTS IN MSC

The MSC does not contain a BTS.

13355 BSC DOES NOT EXIST

The given BSC is invalid.

13356 NO SUCH REFERENCE OBJECT

The reference object is invalid.

13357 THERE ARE TOO MANY BTSS WITH PERIODIC INDICATION METHOD IN BSS

Too many BTSs in the BSS have periodic resource indication method.

13358 NO RESPONSE FROM STATCO

The Statistical Control Program Block did not respond within the speci-fied time limit.

13359 FILE MISMATCH BETWEEN CMU AND STU

There is a file mismatch between BTSFIL in the CMU and BSTRAF in the STU.

13360 NO RESPONSE FROM CM3PRO

CM3PRO did not respond within a specified time limit.

13361 NO RESPONSE FROM CRMPRB

CRMPRB did not respond within the specified time limit.

13362 BSC NAME OR NUMBER ALREADY EXISTS

The BSC already exists.

13363 BSC ADM. STATE CONFLICT

A conflict in the BSC administrative state exists between RNEUPD and CRMPRB.

13364 BSC IS ALREADY RESTARTING

BSC is in reset mode.

13365 SPC UNKNOWN

Unknown signalling point code is given.

13366 SPC ALREADY USED BY ANOTHER BSC

SPC is already used by another BSC.

Page 276: DX Error Messages

276 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13367 SSN AMOUNT EXCEEDED

Too many SSNs.

13368 ROUTE UNKNOWN

The route for signalling point code is unknown.

13369 SIGNALLING LINK IS IN WRONG STATE

The signalling link is in wrong state.

13370 NAME OF BSSAP DOES NOT EXIST

BSSAP ID is invalid.

13371 BSSAP VERSION NAME ALREADY EXISTS

BSSAP version name already exists.

13372 MAXIMUM POOL AMOUNT EXCEEDED

Too large a pool amount.

13373 THERE IS NO BSC IN MSC

There is no BSC in MSC.

13374 LOCATION AREA ALREADY EXISTS IN PLMN

The location area already exists in the PLMN.

13375 PDP CONTEXT ALREADY EXISTS

The subscriber in hostel database already has the given PDP context.

13376 PDP CONTEXT DOES NOT EXIST

PDP context is not found from the subscriber in hostel database.

13377 PDP CONTEXT LIMIT EXCEEDED

The subscriber in hostel database can have max 7 pdp contexts.

13378 INCONSISTENT GPRS DATA

- already PDP type + static PDP address pair - already combination certain PDP type + no PDP address + certain APN - PDP context with static PDP address contains VPLMN allowed flag set yes (either a PDP address or VPLMN allowed flag is tried to be modified).

13379 PRIMARY BASIC SERVICE IS NOT FOUND

The primary basic service is not found

13403 V3 SUPERVISION IS NOT ACTIVE

V3 supervision feature is possible with this ET, but it is not activated.

13404 V3 LOOPBACK IS NOT POSSIBLE

V3 loopback, either in LT or in NT1, is not possible.

13405 DMX EXCEPTION

A process family has made a DMX exception.

13424 SGSN NAME ALREADY EXISTS

If record already exists with the same name when creating an SGSN record to SGFILE.

13425 REQUESTED TASK IDENTIFICATIONS NOT FOUND

Page 277: DX Error Messages

DN987378Issue 24-0

277

General Error Messages of System DX error messages

Id:0900d8058077e097

The application has inquiried copy task identifications, but no identifica-tions were returned. If the task identification of active copy tasks were requested, there were no copy tasks in progress. If the task identifica-tions of logged copy tasks were requested, the copy log was empty.

13426 NO SUCH COPY TASK LOG

The application has requested a copy log or logs, but no information was returned. The copy log was empty or none of the stored logs matched the given filtering criteria.

13428 BCF DELETION DENIED DUE TO BCF-CONTROLLED TRANSMIS-SION EQUIPMENT

The BCF shall not have any other than TRE-1 transmission equipment under its control when it is deleted. Existing transmission equipment may not be in use when the BCF is deleted. Remove other than TRE-1 transmission equipment from BCF control and check states of existing equipment.

13429 POINT-TO-POINT CONFIGURATION NONEXISTENT

The point-to-point configuration supplementary service is nonexistent (it has not been defined).

13430 ADDING OF TRANSMISSION EQUIPMENT FAILED

Adding of transmission equipment failed

13431 FUNCTIONAL ENTITY DOES NOT EXIST

Functional entity does not exist.

13432 HALF RATE CHANNELS ARE NOT ALLOWED WHEN MODIFYING HALF RATE SUPPORT OFF

When the TRXs Half Rate Support (HRS) parameter is switched off there should not exist any half rate channels.

13433 E-GSM900 FREQUENCIES ARE NOT ALLOWED TO 2ND GENERA-TION BTS

Nokia 2nd generation bts does not support E-GSM900 frequencies.

13435 COMMAND PARTLY SUCCESSFUL: SGSN NOT UPDATED

The data cannot be transferred to SGSN correctly. The MAP interface rejects the given operation. However, the data has been stored in the HLR database.

13436 COMMAND PARTLY SUCCESSFUL: NODES NOT UPDATED

The data cannot be transferred to VLR and SGSN correctly. The MAP interface rejects the given operation. However, the data has been stored in the HLR database.

13437 SUPERVISION BLOCK COUNT FOR SELECTIVE STATISTIC COL-LECTION IS EXCEEDED

Supervision block count exceeded in selective statistic collection object definition. Check given supervision block count.

13438 USE OF COMBINED D-CHANNELS NOT POSSIBLE IN THIS BCF

Page 278: DX Error Messages

278 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The site type of BCF does not allow the use of combined D-channels. A Ccmbined D-channel contains both O&M-signalling and telecom signal-ling in the same physical timeslot (PCM-TSL).

13439 NOT FOUND BY TDLRUN

TDLRUN cannot find the object (e.g. a record, a tuple, a collection object, etc) being searched. This code is intended to be used internally by TDLRUN.

13441 FAMILY RESTART ORDERED BY RECOVERY

The recovery system has internally ordered a restart of a process family.

13442 FAMILY RESTARTED DUE SYNCH FAILURE

The family has been restarted due to synchronisation failure.

13443 UPDATING OF CURRENT TIME FAILED BECAUSE OF O&M LINK FAULT

The current time cannot be updated for BTS because the O&M link is down.

13444 IO_TEXT NOT FOUND IN RADIO NETWORK DATABASE

input / output text was not found in the radio network database

13445 OPTION ADVANCED MULTILAYER HANDLING IS NOT IN USE IN BSC.

Feature Advanced Multilayer Handling is optional.

13448 TAPE FILE FORMAT OUT OF ORDER

The tape file format on used media is out of order.

13450 THERE ARE TOO MANY BCFS IN RADIO NETWORK CONFIGURA-TION DATABASE

The maximum number of BCFs is already created to this Radio Network configuration

13451 THERE ARE TOO MANY BTSS IN RADIO NETWORK CONFIGURA-TION DATABASE

The maximum number of BTSs is already created to this Radio Network configuration

13454 PARAMETERS OUT OF RANGE

Parameters are out of their valid ranges in message.

13458 OPTION DIRECT ACCESS TO DESIRED LAYER/BAND IS NOT IN USE IN BSC

The purpose of the DADL/B feature is to direct the traffic in call setup phase from the SDCCH of macro cell / GSM900 cell to the TCH of micro cell / GSM1800 cell whenever possible.

13459 UNKNOWN ABIS AUTOCONFIGURATION POOL REQUEST TYPE

The Abis autoconfiguration pool request type in unknown.

13460 UNKNOWN OR MISSING PARAMETER IN ABIS AUTOCONFIGURA-TION POOL REQUEST

Page 279: DX Error Messages

DN987378Issue 24-0

279

General Error Messages of System DX error messages

Id:0900d8058077e097

There is unknown or missing parameter in Abis autoconfiguration pool request.

13461 ERROR IN READING ABIS AUTOCONFIGURATION POOL FILE (ACQFIL)

Reading the Abis autoconfiguration pool file (ACQFIL) fails.

13462 ERROR IN WRITING ABIS AUTOCONFIGURATION POOL FILE (ACQFIL)

There is an error in writing to Abis autconfiguration pool file (ACQFIL).

13463 THE ABIS AUTOCONFIGURATION POOL FILE (ACQFIL) IS FULL

There is no room in Abis autoconfiguration pool file (ACQFIL).

13464 ERROR IN UPDATING ABIS AUTOCONFIGURATION POOL FILE (ACQFIL) TO HARD DISKS OF BSC

There is an error in updating Abis autoconfiguration pool file to BSC disks.

13465 POOL DELETION DENIED BECAUSE OF ONGOING ABIS ALLOCA-TION PROCEDURE

Abis autoconfiguration pool deletion denied because of ongoing abis allocation procedure.

13466 NO CREATED POOLS FOUND FROM POOL FILE (ACQFIL)

No created pools found from the Abis autoconfiguration pool file (ACQ-FIL).

13467 NO POOLS MATCHING TO GIVEN PARAMETERS FOUND FROM POOL FILE (ACQFIL)

No pools matching to given parameters found from the Abis autoconfig-uration pool file (ACQFIL).

13468 PCM AND/OR TSL(S) ALREADY IN USE IN ANOTHER POOL

Given PCM and/or TSL(s) already in use in another Abis autoconfigura-tion pool.

13469 RESPONSE MESSAGE FROM PXADMI MISSING

PXADMI is not responding to service request.

13470 RESPONSE MESSAGE FROM PUBDAT MISSING

PUBDAT is not responding to service request.

13471 ACKNOWLEDGE MESSAGE FROM BTTEST MISSING

BTTEST is not sending the acknowledge message to service request.

13472 ALL TEST REPORT MESSAGES FROM BTTEST MISSING

All TRX specific test report messages from BTTEST are missing.

13473 REQUEST DENIED DUE TO UNFINISHED ABIS AUTOCONFIGURA-TION PROCEDURE

Request is denied due to unfinished Abis autoconfiguration procedure.

13474 ACMANA IS BUSY

Abis autoconfiguration manager program block is busy.

13475 D-CHANNEL CREATION FAILED

Page 280: DX Error Messages

280 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Creation of the D-channel has failed.

13476 D-CHANNEL DATA INQUIRY FAILED

D-channel data inquiry from PXADMI has failed.

13477 D-CHANNEL MODIFY FAILED

D-channel modifying has failed.

13478 D-CHANNEL ACTIVATION/DEACTIVATION FAILED

Activation/deactivation of the D-channel has failed.

13479 D-CHANNEL REMOVE FAILED

Removing of the D-channel has failed.

13480 RESOLVING OF THE SIGNALLING UNIT FOR THE ACCESS CHANNEL FAILED

Resolving of the signalling unit for the Abis autoconfiguration pool access channel has failed.

13481 ABIS AUTOCONFIGURATION POOL CIRCUIT RESERVATION FAILED

Abis autoconfiguration pool circuit reservation has failed.

13482 ABIS AUTOCONFIGURATION POOL CIRCUIT RELEASING FAILED

Abis autoconfiguration pool circuit releasing has failed.

13483 SOME OF THE RESOURCES IN BTS NOT TESTED DURING BTS AUTOCOMMISSIONING

Some of the resources in BTS has not tested during BTS commission test.

13484 BTS COMMISSIONING TEST FAILED

Commissioning test for the BTS has failed.

13485 NO TRXS INCLUDED IN COMMISSION TEST REQUEST

There are no TRXs included in commission test request.

13486 UNKNOWN ABIS MESSAGE IDENTIFIER FROM BTS

ACMANA has received an unknown Abis message identifier from BTS.

13487 COMMAND ELEMENT (PARAMETER) MISSING FROM THE ABIS MESSAGE

Command element (parameter) of the Abis message received by ACMANA is missing.

13488 ERROR IN INTERNAL FUNCTIONALITY OF THE ACMANA

An error has occured in internal functionality of the ACMANA.

13489 ABIS AUTOCONFIGURATION POOL FULL

There is no more room for allocations in Abis autoconfiguration pool.

13490 MISSING OR WRONG PARAMETER IN ABIS CIRCUIT AUTOCON-FIGURATION REQUEST FROM BTS

There is missing or wrong parameter in Abis circuit autoconfiguration request from BTS.

Page 281: DX Error Messages

DN987378Issue 24-0

281

General Error Messages of System DX error messages

Id:0900d8058077e097

13491 ACKNOWLEDGEMENT FROM BTS TO ABIS CIRCUIT ALLOCATION NOTIFICATION IS MISSING

The acknowledgement from BTS to Abis circuit allocation notification is missing.

13492 WRONG ACKNOWLEDGEMENT FROM BTS TO ABIS CIRCUIT ALLOCATION NOTIFICATION

The acknowledgement from BTS to Abis circuit allocation notification is wrong.

13493 ABIS AUTOCONFIGURATION PROCEDURE INTERRUPTED

Abis autoconfiguration procedure has been interrupted.

13494 ERROR IN ALLOCATING SPEECH CHANNELS FOR A TRX

Speech channel allocation for the TRX has failed.

13495 BTS RESTART INDICATION MISSING

BTS restart indication message is missing.

13496 BCF IS NOT WAITING FOR ABIS AUTOCONFIGURATION

The BCF is not waiting for the Abis autoconfiguration.

13497 TRX IS NOT WAITING FOR ABIS AUTOCONFIGURATION

The TRX is not waiting for the Abis autoconfiguration.

13498 O&M LINK AND TRX LINK BIT RATE MISMATCH IN LINK COMBIN-ING

There is a O&M link and TRX link bit rate mismatch in link combining.

13499 THE BIT RATE OF THE TRX LINK DOES NOT CORRESPOND WITH THE SUBTIMESLOTS RESERVED FOR OPTIMN

The bit rate of the TRX link does not correspond with the subtimeslots reserved for optimized Abis allocation.

13500 TEXT IS ILLEGAL

Text contains either no character or it has illegal characters.

13501 BCF IS WAITING ABIS AUTOCONFIGURATION.

BCF, which is created to be autoconfigured, is waiting abis autoconfig-uration in BL-WAC operative state.

13502 OBJECTS LOCKED UNDER BCF WAITING ABIS AUTOCONFIGURA-TION.

Under BCF, which is waiting abis autoconfiguration, is locked BTS or TRX.

13503 INPUTS ARE NOT VALID FOR THE SITE TYPE

The type of BCF (defined by BCF parameter BTS site type) does not support inputs (e.g. external alarms)

13504 GIVEN TASK IDENTIFICATION IS NOT UNIQUE

The given task identification is not unique. For example the backup copy task is rejected, if the copy log already contains information of a task of identical identification.

Page 282: DX Error Messages

282 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13511 OPTION FLEXIBLE COUNTER SELECTION SET IS NOT IN USE IN BSC

Flexible counter selection set feature is not supported in the BSC.

13513 COMMUNICATION ERROR WITH TETRA ENCRYPTION MODULE

An error in the communication with a Tetra encryption module has occured.

13514 MEMORY OF TETRA ENCRYPTION MODULE FAULTY

The memory of Tetra encryption module is faulty.

13515 TETRA ENCRYPTION MODULE COUNTER TEST ERROR

Tetra encryption module counter test is incorrect.

13516 TETRA ENCRYPTION MODULE SERIAL PORT TEST ERROR

Tetra encryption module serial port test is incorrect.

13517 TETRA ENCRYPTION MODULE RANDOM NUMBER GENERATOR FAULTY

The random number generator of Tetra encryption module is faulty.

13518 ZONE CODE ALREADY EXISTS

Zone Code already exists in Zone Code Index table (ZCITBL) of radio network file.

13519 ZONE CODE NAME ALREADY EXISTS

Zone Code Name already exists in Zone Code Name table (ZCNTBL) of radionetwork file.

13520 NO MORE FREE SIGNALLING CAPACITY WITH CURRENT HW OR SW CONFIGURATION

There is no more free signalling capacity to create any new signalling links. Capacity of AS7 plug-in-units has been run out.

13521 SPECIAL ROUTE ATTACHED

The given special route is attached to a component.

13522 THE GSMP FUNCTIONALITY IS ENABLED

The GSMP functionality is enabled. The GSMP control channel cannot be deleted when the GSMP functionality is enabled.

13525 ATM CROSS CONNECTION SERVICES ARE NOT RESPONDING

ATM cross connection services are not responding to a service request. Check that the service provider is alive and try again.

13526 TESTING OF THE REQUESTED OBJECT IS NOT ALLOWED

The BTTEST rejects the testing of the unallowed test object.

13527 TIME SLOT USED TO SIGNALING

Testing is not allowed because timeslot is used to signalling.

13528 TEST INTERRUPTION IS NOT ALLOWED

Test interruption request is received in state where interruption is not allowed.

13529 ABIS LOOP TEST LOOP CONNECTION FAILED

Page 283: DX Error Messages

DN987378Issue 24-0

283

General Error Messages of System DX error messages

Id:0900d8058077e097

Loop connection to the GSWB failed.

13530 TESTING OF CONTROL CHANNEL NOT ALLOWED

Abis loop test is requested to the radio timeslot which is dedicated to be as control channel.

13531 EXTENDED FREQUENCIES USED WITH STM EQUIPMENT

Extended frequencies are not allowed with STM test equipment.

13532 SYSTEM KEY OF TETRA ENCRYPTION MODULE IS FAULTY

The system key of Tetra Encryption module is faulty.

13533 PDP CONTEXT LIMIT EXCEEDED IN HOSTEL DATABASE

The subscriber in hostel database can have maximum 7 pdp contexts.

13534 DISTINCTIVE RINGING NOT ALLOWED

A notice related to subscriber handling - inquiry, creation, or deletion. The notice means that the subscriber has the distinctive ringing facility on, and the subscriber handling command is not allowed on subscribers with distinctive ringing facility.

13535 TRANSMISSION EQUIPMENT DELETION DENIED

Transmission equipment in question can not be deleted.

13536 UNABLE TO WRITE DATA ON VDS DEVICE DUE THE STATE OF DATA FILES.

VDS device driver is unable to write data on the hard disk file due the state of current data file is FULL and overwriting is disabled. If skiping of FULL files is enabled, VDS device driver has not found any files in TRANSFERRED state.

13537 THE STATUS OF VDS DATA FILE IS NOT CHANGED DUE THE REQUESTED STATE TRANSITION IS ILLEGAL

The status of VDS data file is not changed due the requested status transition is illegal.

13538 VDS DEVICE DRIVER IS UNABLE TO STORE DATA DUEINITIALIZA-TION OF DATA FILE HAS FAILED

VDS device driver is unable to store data due initialization of data file has failed.

13539 VDS DEVICE DRIVER IS UNABLE TO STORE DATA ON HARD DISKS

VDS device driver is unable to store data on hard disks.

13540 VDS DEVICE DRIVER IS UNABLE TO HANDLE THE REQUESTED TASK DUE THE STATE OF COMPUTER UNIT

A request is send to VDS device driver in computer unit which state does not allow requested task to be completed.

13541 CHECKSUM POLLING ALREADY ON

The checksum polling is already going on.

13542 EQUIPMENT COLLECTION ALREADY ON

The equipment collection is already going on.

Page 284: DX Error Messages

284 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13543 NEGATIVE ACKNOWLEDGEMENT FROM BASE STATION

The BTS has replied with a negative acknowledgement message to the POOL_SIZE_REPORT or AC_BSC_CIRCUITS_ALLOCATED message sent by ACMANA Program Block during Abis Autoconfigura-tion procedure.

13544 ABIS AUTOCONFIGURATION PROCEDURE INTERRUPTED BY BTS

The BTS has interrupted the Abis Autoconfiguration procedure by send-ingthe AC_INTERRUPTED message to ACMANA Program Block.

13545 CANNOT COMBINE OMUSIG AND TRXSIG LINKS

The combining of OMUSIG and TRXSIG during Abis Autoconfiguration cannot be completed. Either the OMUSIG or the TRXSIG for the TRX 1 has already been allocated or requires no allocation for some other reason.

13546 PROCESSOR OF TETRA ENCRYPTION MODULE FAULTY

The processor of TETRA Encryption module is faulty.

13547 WRONG MESSAGE FROM BTS DURING ABIS AUTOCONFIGURA-TION

The BTS has replied with an Abis message that does not belong to the current Abis Autoconfiguration phase.

13548 UNKNOWN LINK BIT RATE IN ABIS AUTOCONFIGURATION

The link bit rate (OMUSIG or TRXSIG) read from the BSC Radio Network Database or from the DCHSET File is unknown to ACMANA Program Block.

13549 WRONG BSC C-NUMBER FROM BTS DURING ABIS AUTOCONFIG-URATION

The BSC C-number sent by BTS in the AC_CIRCUIT_REQ message differs from the own BSC C-number.

13550 NO RESPONSE FROM GUPDAT TO THE BCF RESERVE OR RELEASE REQUEST

No response from GUPDAT to the BCF reserve/release request sent by ACMANA program Block during Abis Autoconfiguration.

13551 GSMP SERVICES SERVICE PROVIDER NOT RESPONDING

The service provider for GSMP Services does not respond to service request.

13552 THE SPECIFIED ATM INTERFACE HAS NOT GOT A GSMP PORT DEFINED

The interface specified in the request does not have a GSMP port defined.

13553 CIRCUIT GROUP DEFINITION IS NOT FOUND FROM NTN DATABASE

Circuit group is not found from database.

13554 DXT ALREADY EXISTS IN NTN DATABASE

dxt already exists in ntn database

Page 285: DX Error Messages

DN987378Issue 24-0

285

General Error Messages of System DX error messages

Id:0900d8058077e097

13555 BOLERO DATA AREA NOT FOUND

BOSLIB did not find BOLERO data area or did not recognize it (e.g. wrong version).

13556 DATA DID NOT FIT IN BOLERO DATA AREA

The area reserved for data is smaller than the data you tried to save.

13557 DATA WAS NOT FOUND IN BOLERO

The given data was not found in BOLERO data area.

13558 BOSLIB DID NOT RECOGNIZE THE DATA

BOSLIB did not recognize the data id as BOLERO data.

13559 BOLERO DATA IS WRITE PROTECTED

The data can not be written into BOLERO data area, because the area of the data is write protected.

13560 BOLERO DATA INDEX IS TOO LARGE

There are not so much data records in BOLERO data area as the index asks for.

13561 BLSLIB NOT INITIALIZED

BLSLIB has not been initialized (with the library initialization function).

13562 DATA NOT FOUND IN BLSLIB AREA

There is no record in BLSLIB data area that would contain the data.

13563 DATA IS TOO LARGE IN BLSLIB AREA

Data is so large in BLSLIB data area that it cannot be read into the given area.

13564 BLSLIB AREA IS FULL

The data cannot be saved in the BLSLIB data area, because it does not fit in the free area at the moment.

13565 DATA SCOPE NOT RECOGNIZED

BLSLIB did not recognize the scope of the data.

13566 DATA LIFETIME NOT RECOGNIZED

BLSLIB did not recognize the lifetime of the data.

13567 INDEX BIGGER THAN THE AMOUNT OF RECORDS

The index of the data is bigger than the amount of records in BLSLIB data area.

13568 V5 INTERFACE IS NOT ACTIVATED

The V5 interface is created but not activated.

13569 MATCHING V5 INTERFACE NOT FOUND

Inquired V5 interface was not found.

13570 DATABASE IS WAITING FOR INITIALIZATION MESSAGE

The database management system is started but has not received an initialization message.

13571 REMOVING OF DXT IS NOT ALLOWED, BEFORE ALL G4WIFS ARE REMOVED

Page 286: DX Error Messages

286 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Removing of dxts is not allowed, before all g4wifs are removed.

13572 REMOVING OF DXT IS NOT ALLOWED, BEFORE ALL CIRCUIT GROUPS ARE REMOVED

Removing of dxt is not allowed, before all circuit groups are removed.

13573 REMOVING OF DXT IS NOT ALLOWED, BEFORE ALL DXT_SERVICES ARE REMOVED

Removing of dxt is not allowed, before all dxt_services are removed.

13574 VCLTP DOES NOT EXIST

The given identifier is not assigned to any existing VCLtp.

13575 VCI ALREADY EXISTS

The given identifier is already in use under the specified VCLtp.

13576 VCLTP EXISTS

The operation could not be performed because there are VCLtps under the VPLtp.

13577 VC DATA INCONSISTENT IN THE SYSTEM

An error ocurred during the command execution. Corrective actions could not restore the consistency of the databases.

13578 GSMP SWITCH INFO NOT DEFINED

The switch information for GSMP does not exist in the database.

13579 NO ACKNOWLEDGEMENT FOR HOT DATA TRANSFER

Timer which supervises TPPIPE (Transport Pipe Provider) interface has expired.

13580 INVALID TPI LEVEL

Termination point level information is not suitable for requested opera-tion.

13581 STATE CHANGE NOT ALLOWED

The requested state change is not allowed. For example the adminis-trative state from locked -> shutting down state is not allowed transition.

13582 REMOTE SYSTEM IS NOT READY TO RECEIVE HOT DATA

Remote system can not receive immediately sent hot records.

13583 GIVEN SERVICE CATEGORY IS NOT ALLOWED

The given service category is not defined, or service category of VPCtp and VCLtp mismatch.

13584 CONNECTION DOES NOT EXIST

The specified connection does not exist.

13585 TP IS CONNECTED

The specified termination point is connected.

13586 TP DOES NOT SPECIFY A PTM ROOT

The given termination point does not specify a root termination point of a point-to-multipoint connection.

13587 UNABLE TO DELETE LAST BRANCH SEPARATELY

Page 287: DX Error Messages

DN987378Issue 24-0

287

General Error Messages of System DX error messages

Id:0900d8058077e097

The last branch of a point-to-multipoint connection may not be deleted with the delete branch command. The delete connection command must be used.

13588 CONNECTION DATA INCONSISTENT IN THE SYSTEM

An error occurred during the command execution. Corrective actions could not restore the consistency of the databases.

13589 TERMINATION MANAGEMENT SERVICE NOT RESPONDING

Termination management service is not responding to a service request in a given time. The service could be down or busy. Try to request the service again.

13590 G4WIF DATA IS NOT FOUND FROM NTN DATABASE

G4wif data is not found from ntn database.

13592 VPI ALREADY EXISTS

The given VP identifier is already in use under the specified interface.

13593 VPLTP EXISTS

The operation could not be performed because there are VPLtps under the interface.

13594 TP IS NOT UNLOCKED

The operation could not be performed because the state of the termina-tion point is not unlocked.

13595 TP DOES NOT SPECIFY A PTM BRANCH

The specified operation can only performed on a termination point related to a ptm branch.

13596 TP SPECIFIES A PTM BRANCH

The operation could not be performed because the given termination point specifies a ptm branch.

13597 VPLTP SERVICE LEVEL IS VPC

The specified VPLtp has been configured for VP connections.

13598 VPLTP SERVICE LEVEL IS VCC

The specified VPLtp has been configured for VC connections.

13599 VPLTP SERVICE TYPE ALLOWS NO PVC

The specified VPLtp has been configured for switched (SVC) connec-tions.

13600 VPLTP SERVICE TYPE ALLOWS NO SVC

The specified VPLtp has been configured for permanent (PVC) connec-tions.

13601 TERMINATION POINT IS NOT IN LOCKED STATE

The specified operation requires the termination point to be in locked administrative state.

13602 VPI IS INSIDE GSMP PORT

Page 288: DX Error Messages

288 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The specified VPLtp is inside a GSMP port and the requested operation can not be performed. Specify a different VPLtp or use GSMP handling commands to handle this VPLtp.

13603 VP DATA INCONSISTENT IN THE SYSTEM

An error occured during the command execution. Corrective actions could not restore the consistency of the database.

13604 CONNECTION ERROR

An error has occured with connection in AAPSEB service block.

13605 TRANSFER ERROR

An error has occured with transfer in AAPSEB service block.

13606 USED SERVICES NOT KNOWN

Used services are not known and thus the service request cannot be served. Try again later.

13607 ATM LINE ALREADY IN USE

The given line on specified plug-in unit is already in use by another ATM interface.

13608 ATM INTERFACE DOES NOT EXIST

The given identifier is not assigned to any existing ATM interface.

13609 ATM INTERFACE IS NOT LOCKED

The operation could not be performed because the ATM interface is not locked.

13610 ATM INTERFACE DATA INCONSISTENT IN THE SYSTEM

An error ocurred during the command execution. Corrective actions could not restore the consistency of the databases.

13611 ATM INTERFACE HAS A GSMP PORT DEFINED

The operation could not be performed cause the ATM interface has a GSMP port assigned to it.

13612 ACCESS PROFILE EXISTS

The specified ATM interface already has a profile.

13613 ACCESS PROFILE DOES NOT EXIST

The specified ATM interface does not have a profile.

13614 CURRENTLY MORE VP CONNECTIONS DEFINED

The modification attempted to reduce the number of VP connections allowed on the ATM interface. Currently there are more VP connections than the new value would allow.

13615 CURRENTLY MORE VC CONNECTIONS DEFINED

The modification attempted to reduce the number of VC connections allowed. Currently there are more VC connections than the new value would allow. Increase the parameter "maximum number of VCCs" or give the command again later.

13616 CURRENT CONNECTIONS USE MORE VCI BITS

Page 289: DX Error Messages

DN987378Issue 24-0

289

General Error Messages of System DX error messages

Id:0900d8058077e097

The modification attempted to reduce the number of bits used in the VCI. Currently there are connections whose VCI requires more bits than the new value would allow. Increase the parameter "maximum number of VCI bits" or give the command again later.

13617 ACCESS PROFILE DATA INCONSISTENT IN THE SYSTEM

An error ocurred during the command execution. Corrective actions could not restore the consistency of the databases.

13618 ATM INTERFACE ID ALREADY EXISTS

The given identifier is already assigned to another ATM interface. Repeat the command with a suitable value or let the system select a free one.

13619 QOS AND SERVICE CATEGORY MISMATCH

The given QoS class for termination point or connection does not match the given service category.

13620 TRAFFIC PARAMETERS AND SERVICE CATETORY MISMATCH

The given traffic parameters for termination point or connection do not match the service category.

13621 THE VPLTP DOES NOT EXIST

The given VP identifier is not assigned to any existing VPLtp.

13622 FATAL ERROR

The error code informs, that unrecoverable error has occured.

13623 VPLTP HAS AN ACCESS PROFILE

The specified VPLtp already has an access profile.

13624 VPLTP HAS NO ACCESS PROFILE

The specified VPLtp does not have an access profile.

13625 VPLTP DOES NOT EXIST

The given VP identifier is not assigned to any existing VPLtp.

13626 OBJECT ALREADY IN USE

error code to report when the requested object is already in use.

13627 MANY G4WIF OBJECT MEMBERS OF A GROUP

Error Code to report when the Group has already the maximum no of g4wifobjects as members.

13628 SIGNALLING LINK ID ALREADY IN USE

Signalling link-id is already in use.

13629 SIG_SERVICE_ERROR_EC

Error in creating a new hand for signalling link

13630 SIGNALLING TYPE NOT AVAILABLE

Signalling type is unknown.

13631 UNKNOWN SIGNALLING LINK ID

Signalling link_id is unknown.

13632 SYSTEM KEY FILE OF TETRA ENCRYPTION MODULE IS FAULTY

Page 290: DX Error Messages

290 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The system key file of Tetra Encryption module is faulty.

13633 SAR STATUS QUEUE EMPTY

There are no RSM Status Queue entries ready to return or no available SEG Status Queue entry to release.

13634 CHECKING OF WS SESSION FAILED

This error code is used to indicate that there was an error getting session information from database.

13635 WS HAS NO SESSION

This error code is used to indicate that there is no users logged on to WS.

13636 CHECKING OF WS USER RIGHTS FAILED

This error code is used to indicate that there was an error in checking WS user rights.

13637 NO ACKNOWLEDGEMENT RECEIVED FROM DXT

This error code is used to indicate that DXT has not answered to a request.

13638 SENDING MESSAGE IN SEGMENTS FAILED

This error code is used to indicate that there was an error when sending a segmented message.

13639 RECEIVING MESSAGE IN SEGMENTS FAILED

This error code is used to indicate that there was an error when receiv-ing a segmented message.

13640 MESSAGE SEGMENT HAS A WRONG TYPE

This error code is used to indicate that the received message segment has not the correct type. This means that when the data is expected, an acknowledgement to a segment is received or other way around.

13641 MESSAGE SEGMENT ALREADY RECEIVED

This error code is used to indicate that the received message segment is already received before.

13642 MESSAGE SEGMENTS IN WRONG ORDER

This error code is used to indicate that message segments are coming in wrong order.

13643 ACKNOWLEDGEMENT TO WRONG MESSAGE SEGMENT

This error code is used to indicate that the received acknowledgement to a segment is not the expected one.

13644 WRITING DATA TO A BUFFER FAILED

This error code is used to indicate that there was an error when writing data to a buffer.

13645 WS USER HAS NO RIGHTS TO DELETE RADIO SUBSCRIBER

This error code is used in WCRPRB, when ws users right for the delete-command is checked.

13646 WS USER HAS NO RIGHTS TO CREATE RADIO SUBSCRIBER

Page 291: DX Error Messages

DN987378Issue 24-0

291

General Error Messages of System DX error messages

Id:0900d8058077e097

This error code is used in WCRPRB, when ws users right for the create-command is checked.

13647 ISSI OF A RADIO SUBSCRIBER IS NOT IN ALLOWED ISSI RANGE OF WS USER

This error code is used in WCRPRB, when ws users right for the create-command is checked.

13648 WS USER HAS NO RIGHTS TO MODIFY ORG. BLOCK ID OF RADIO SUBSCRIBER

This error code is used in WCRPRB, when ws users right for the modify-command is checked. This is used when the WS user has already the right to modify the WS user. But if he wants to modify the org. block id of the WS user, he must have the right to create or delete WS user both to the old and new org. block.

13649 WS USER HAS NO RIGHTS TO MODIFY RADIO SUBSCRIBER AT ALL

This error code is used in WCRPRB, when ws users right for the modify-command is checked.

13650 OPEN-LEVEL STACK OVERFLOW/UNDERFLOW

Stack which stores open levels has overflowed or underflowed. Reason for underflow is probably pop-operation without push. Possible causes for overflow are too small amount of nesting levels, or too many push-operations / level.

13651 CURRENT LEVEL IS UNDEFINED

Used operation requires TLV-code containing at least one level.

13652 TAG SHOULD BE READ INSTEAD

Tag must be read before using this operator.

13653 VALUE SHOULD BE READ INSTEAD

Value must be read or skipped before using this operator.

13654 EMPTY CONSTRUCTED ELEMENT

Every constructed element must contain at least one subelement.

13655 TAG CLASS WAS UNKNOWN

Only application-class tags can be decoded. This error is probably caused by invalid TLV-code.

13656 TLV-CODE IN NOT VALID

TLV-code is not valid. Probably this is caused by conflicting length in TLV-code.

13657 TAG FIELD IS TOO LONG

Tag does not fit to space reserved for it. This may indicate invalid TLV-code.

13658 LENGTH FIELD IS TOO LONG

Length of value does not fit to space reserved for it. This may indicate invalid TLV-code.

13659 EMPTY-VALUE STACK OVERFLOW/UNDERFLOW

Page 292: DX Error Messages

292 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Stack which stores locations of empty values has overflowed or under-flowed. Reason for underflow is probably attempt to fill empty value without adding it first. Possible cause for overflow is too small maximum amount for empty values.

13660 DIFFERING LENGTHS WHILE FILLING VALUE

Lengths given for "add_next_empty" and "fill_empty_val" are differing.

13661 TLV-CODE CONTAINS EMPTY VALUES

All empty values must be filled before finishing encoding.

13662 PARAMETER WITH UNIT IS TOO BIG

The given parameter, a combination of numerical value and unit, results in a value which is too big.

13663 DXT NOT DEFINED

The given DXT has not been defined in this exchange of the network.

13664 CIS NODE DEFINITION IS NOT FOUND FROM NTN DATABASE

Cis node definition is not found from ntn database.

13665 CIS NODE ALREADY EXISTS IN NTN DATABASE

Cis node is already found in ntn database

13666 ERROR CODE FOR BACK GROUND GROUP

Main level error code reported when DWS tries to add members to a background group, when the group downloading is not used.

13667 ILLEGAL OPERATION FOR THE MS TYPE

Error code reported in the ec list when the operation is not allowed for the requested MS.

13668 CONNECTION GROUP HAS CIRCUIT GROUPS.

Connection group has circuit groups.

13669 END OF CURRENT LEVEL IS REACHED

Current level is read completely. End of some upper levels can be reached simultaneously.

13670 INVALID HANDOVER REASON

the handover reason is wrong or not possible.

13671 DXT WITH GIVEN SHORT DXT IDENTITY VALUE ALREADY EXISTS IN NTN DATABASE

Dxt with given short dxt identity already exists in ntn database.

13672 DXT WITH GIVEN LOCATION IDENTITY VALUE ALREADY EXISTS IN NTN DATABASE

Dxt with given location identity value already exists in ntn database

13673 DXT WITH GIVEN OWN-FLAG VALUE ALREADY EXISTS IN NTN DATABASE

Dxt with given own-flag value already exists in ntn database

13674 RIGHT TO ACTIVATE CALLING NUMBER DELIVERY NOT SET

The right to activate calling number delivery is not set.

Page 293: DX Error Messages

DN987378Issue 24-0

293

General Error Messages of System DX error messages

Id:0900d8058077e097

13675 CALLING NUMBER DELIVERY SET

Calling number delivery is set.

13676 TYPE OF ADVICE OF CHARGE NOT SET

Type of advice of charge (IAO) is not set.

13677 TYPE OF ADVICE OF CHARGE SET

Type of advice of charge (AOD, AOE, AOS, ACD, ACE or ACS) is set.

13678 CALL WAITING NOT SET

Call waiting (CW) is not set.

13679 RIGHT TO NOTIFY CALLING SUBSCRIBER THAT CALL WAITING HAS BEGUN SET

Right to notify calling subscriber that call waiting has begun (CWN) isset.

13680 CALL DIVERSION ON HOOK NOT SET

Call diversion on hook (CTH) is not set.

13681 FAST TRANSFER SET

Fast transfer to ringing (CTF) or Fast transfer to busy (CTB) is set.

13682 THREE PARTY SERVICE SET

Three party service (IPTY) is set.

13683 THREE PARTY AND HOLD FOR ENQUIRY SET

Three party and hold for enquiry (PS) are set.

13684 CALL HOLD FACILITY NOT SET

Call hold facility (HOLD) is not set.

13685 RIGHT TO USE COMPLETION OF CALLS TO BUSY SUBSCRIBERS SET

Right to use completion of calls to busy subscribers (CCS) is set.

13686 RIGHT TO ACTIVATE BARRING OF COMPLETION OF CALLS TO BUSY SUBSCRIBERS SET

Right to activate barring of completion of calls to busy subscribers (CCR) is set.

13687 RIGHT TO USE NUMBER REPETITION IN COMPLETION OF CALLS TO BUSY SUBSCRIBERS (PRE-CCBS) SET

Right to use number repetition in completion of calls to busy subscribers (pre-CCBS) is set.

13688 FIXED DESTINATION CALL IS ACTIVE SET

Fixed destination call is active (FD) is set.

13689 DIRECT DIALLING-IN NOT SET

Direct dialling-in (DDI) is not set.

13690 COMMON PART LENGTH OF MSN NUMBER SET

Common part length of MSN number (DCP) is set.

13691 CALL TRACING IS ON

Call tracing (CT, CTT/MI) is on.

Page 294: DX Error Messages

294 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13692 ISDN GROUP CALL NUMBER

ISDN group call number.

13693 CAC CHECKING ACTIVATED NOT SET

CAC checking activated (CA) is not set.

13694 INTERNATIONAL CAC CHECKING ACTIVATED NOT SET

International CAC checking activated (CAI) is not set.

13695 SPECIFIED ATM INTERFACE DOES NOT EXIST

The specified ATM interface is not defined for the given plug-in unit.

13696 SSCF SERVICE ERROR

Error in SSCF service provider.

13697 SSCOP SERVICE ERROR

Error in SSCOP service provider.

13698 PARSE ERROR

An error occured while parsing the input parameters of the command.

13699 BCF IS RESERVED TO SOME OTHER TEST

Test execution is not possible because the BCF resource is reserved to some other test.

13700 TESTING IS NOT REQUESTED TO THIS TEST OBJECT

This test object do not belong to test objects whose testing is requested.

13701 SOME OF THE RADIO TIME SLOTS ARE NOT TESTED SUCCESS-FULLY

Radio time slots assosiated to the tested TRX are not tested success-fully

13702 ZONE CODE NOT UPDATED

The update of the zone code data failed.

13703 HARDWARE INITIALIZATION FAILED

This is a general error code for hardware initialization failure.

13704 2M LINK DOES NOT EXIST

2M link does not exist.

13705 V5 INTERFACE IS ALREADY SHUT DOWN

V5 interface is already shut down

13706 TABLE ERROR IN AAPSEB

AAPSEB SW has found an error in its internal table.

13707 RNGLIB IS OUT OF RAND NUMBERS

RNGLIB is out of random numbers, pseudo random numbers used instead.

13708 THE PXADMI DOES NOT ANSWER TO THE D-CHANNEL CREATION OR DELETION

The pxadmi does not response to the creation or deletion message of D-channel.

Page 295: DX Error Messages

DN987378Issue 24-0

295

General Error Messages of System DX error messages

Id:0900d8058077e097

13709 D-CHANNEL CREATION DOES NOT SUCCEED IN AUTOCONFIG-URED TRX/BCF CREATION

In the creation of autoconfigured BCF/TRX the creation of d-channel does not succeeded.

13710 THE COMBINED LINK DOES NOT EXIST IN THE CREATION OF AUTOCONFIGURED TRX

The combined d-channel link does not exists when the autoconfigured trx is created.

13711 FAMILY RESTARTED

Family restarted manually.

13712 RNW ALARM SYSTEM INTERNAL BUFFER OVERFLOW

All RNW alarms haven t been able update to alarmhistoryfile and internal alarmhistory buffer has filled. This causes that some alarms are missing from alarmhistory.

13713 TRANSMISSION EQUIPMENT HAS WRONG STATE

Transmission equipment has wrong state for the requested operation.

13714 THE REQUESTED WS USER IS NOT CURRENTLY LOGGED

The requested ws user is not currently logged.

13715 TOO MANY FREQUENCIES IN BTS

There are more frequencies in BTS than can be in cell allocation.

13716 PASSWORD CONTAINS ILLEGAL CHARACTER(S)

Password contains at least one illegal character.

13717 TBS IS NOT DEFINED IN NTN DATABASE.

Tbs is not defined in ntn database.

13718 FUN UNIT IS NOT FOUND IN NTN DATABASE

Fun unit is not found in ntn database.

13719 FUN UNIT ALREADY EXISTS IN NTN DATABASE

Fun unit already exists in ntn database.

13720 PCM-TSL NUMBER IS TOO HIGH

PCM-TSL number is too high.

13721 SUBSCRIBER HAS NO INTERFACES TO HW-EQUIPMENT

Subscriber has no interfaces to hw-equipment.

13722 REMOVING OF DXT IS NOT ALLOWED,BEFORE ALL TRCS ARE REMOVED

Removing of dxt is not allowed before all trc:s are removed.

13723 CGR IS ALREADY DEFINED TO THIS DXT

Circuit group is already defined to this dxt.

13724 CGR ALREADY EXISTS IN NTN DATABASE

Circuit group already exists in ntn database.

13725 CGR OF THIS DXT IS NOT FOUND

Circuit group is not connected to this dxt.

Page 296: DX Error Messages

296 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13726 PCM-TSL IS NOT FOUND IN NTN DATABASE

PCM-TSL is not found in ntn database.

13727 RELATION TO PCM-TSL IS NOT FOUND

Relation to PCM-TSL is not found

13728 CONNECTION GROUP ALREADY EXISTS IN NTN DATABASE

Connection group already exists in ntn database.

13729 GATEWAY IS ALREADY FOUND IN NTN DATABASE

Gateway is already found in ntn database

13730 CONNECTION GROUP IS NOT FOUND IN NTN DATABASE

Connection Group is not found in ntn database

13731 PHYSICAL ADDRESS MANAGEMENT IS INITIATED

Physical address management has already been initiated, so initiation calls will not be accepted any more.

13732 D-CHANNEL DELETION DOES NOT SUCCEED IN AUTOCONFIG-URED TRX/BCF CREATION/DELETION

In the creation/deletion of autoconfigured TRX/BCF, the deletion of D-channel does not succeed.

13733 ATM CROSS CONNECTION PATH SERVICE NOT RESPONDING

ATM cross connection path service provider is not responding.

13734 LINE ALREADY EXISTS IN THIS CIRCUIT GROUP

Line already exists in this circuit group.

13735 FUNCTIONAL UNIT FOUND TO THIS REMOTE OBJECT

Functional unit found to this remote object

13736 LINE IS NOT IN THIS CIRCUIT GROUP

Line is not in this circuit group

13737 EXTERNAL LINE DOES NOT HAVE CIRCUIT GROUP PARAME-TERS

External line does not have circuit group parameters

13738 DXT SERVICE OBJECT MISSING FROM CONNECTION GROUP

Dxt service object missing from connection group

13739 EXTERNAL LINE IS NOT FOUND FOR CIRCUIT GROUP

External line is not found for circuit group

13740 SOFTWARE LINE INDEX ALREADY FOUND

Software line index already found

13741 CONFLICT WITH FNIM AND EXTERNAL LINE PCM-NUMBERS

Conflict with fnim and external line pcm-numbers

13742 CONFLICT IN EXTERNAL LINE SSI

Conflict in external line ssi

13743 TSL IS MISSING FROM EXTERNAL LINE

Tsl is missing from external line

Page 297: DX Error Messages

DN987378Issue 24-0

297

General Error Messages of System DX error messages

Id:0900d8058077e097

13744 THE D-CHANNEL DATA INQUIRY DOES NOT SUCCEED

The D-channel data inquiry does not succeed.

13745 CREATING COMBINED LINK IS POSSIBLE

Creating a combined link is possible.

13746 DELETING COMBINED O&M LINK NOT ALLOWED

Deleting a combined O&M link not allowed.

13747 VCC WAS ALREADY RESERVED

VCC was already reserved to another process.

13748 VCC IS RESERVED TO ANOTHER PROCESS FAMILY

VCC cannot be released because it is reserved to another process family.

13749 VCC WAS FREE

VCC was not released because it was free.

13750 RESERVED TO ANOTHER PROCESS FAMILY

VCC is reserved to another process family.

13751 VCC IS FREE

Supervised VCC is free.

13752 LINK SUPERVISION ERROR

Link supervision error.

13753 PACKET DISCARD VALUES CONFLICT. EPD- AND PPD-ENABLE SHOULD HAVE THE SAME VALUES.

The hardware does not support different values for Early Packet Discard (EPD) and Partial Packet Discard (PPD). They have to be either both enabled or both disabled.

13754 RECOVERY IS BUSY DUE TO SYM UNIT RESTART

RECOVERY IS BUSY AT THE MOMENT DUE TO SYM UNIT RESTART.

13755 RACK OR CABINET TYPE ALREADY EXISTS

The rack or cabinet already exists and cannot be created in equipment database.

13756 CABINET HMS INDEX ALREADY EXISTS

The HMS index of cabinet already exists in equipment database, and thus this HMS index cannot be used.

13757 RACK OR CABINET DOES NOT EXIST

The rack or cabinet does not exist in equipment database, and thus it cannot be deleted or a subrack cannot be created for it.

13758 RACK OR CABINET HAS SUBRACKS

The rack or cabinet has subracks in equipment database and thus it cannot be deleted.

13759 INCORRECT RACK OR CABINET TYPE

Page 298: DX Error Messages

298 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The given rack or cabinet type is incorrect and thus it cannot be created in equipment database.

13760 SUBRACK ALREADY EXISTS

The subrack already exists in equipment database and thus it cannot be created again.

13761 SUBRACK HMS INDEX ALREADY EXISTS

The subrack HMS index already exists in equipment database, and thus the given index cannot be used.

13762 SUBRACK DOES NOT EXIST

The subrack does not exist in equipment database and thus it cannot be deleted.

13763 SUBRACK HAS PIUS

The subrack has plug-in units in equipment database and thus it cannot be deleted.

13764 INCORRECT SUBRACK TYPE

The subrack type is incorrect and thus it cannot be created in equipment database.

13765 PLUG-IN UNIT ALREADY EXISTS

The plug-in unit already exists in equipment database and thus it cannot be created again.

13766 PLUG-IN UNIT DOES NOT EXIST

The plug-in unit does not exist in equipment database and thus it cannot be e.g. deleted or connected.

13767 PLUG-IN UNIT HAS CONNECTED PORTS

The plug-in unit has connected ports in equipment database and thus it cannot be deleted.

13768 PLUG-IN UNIT HAS NO FREE RESOURCES

The plug-in unit has no free resources in equipment database and thus no new resources can be reserved from it.

13769 PLUG-IN UNIT HAS NO RESERVED RESOURCES

The plug-in unit has no reserved resources in equipment database and thus resources cannot be freed from it.

13770 PLUG-IN UNIT IS ATTACHED TO UNIT

The plug-in unit is attached to a unit and thus cannot be deleted from equipment database.

13771 PLUG-IN UNIT HAS RESOURCES IN USE

The plug-in unit has reserved resourses in equipment database, and thus it cannot be deleted.

13772 PLUG-IN UNIT IS ALREADY ATTACHED TO UNIT

The plug-in unit is already attached to a unit and thus it cannot be attached again.

13773 PLUG-IN UNIT IS NOT ATTACHED TO UNIT

Page 299: DX Error Messages

DN987378Issue 24-0

299

General Error Messages of System DX error messages

Id:0900d8058077e097

The plug-in unit is not attached to a unit and thus cannot be deattached.

13775 UNIT ALREADY EXISTS

The unit already exists in equipment database and thus cannot be created.

13776 UNIT DOES NOT EXIST

The unit does not exist in equipment database, and thus it cannot be deleted.

13777 INCORRECT UNIT TYPE

The unit type is incorrect or unit group index is invalid, and thus it cannot be created or deleted from equipment database.

13778 UNIT ATTACHMENT DOES NOT EXIST

The unit attachment does not exist in equipment database, and thus it cannot be deattached.

13779 PORT OF PLUG-IN UNIT DOES NOT EXIST

The port of plug-in unit does not exists in equipment database, and thus it cannot be connected.

13780 CONNECTION BETWEEN PORTS ALREADY EXISTS

The connection between ports of plug-in unit already exists, and thus the ports cannot be connected.

13781 CONNECTION BETWEEN PORTS DOES NOT EXIST

The connection between ports of plug-in units does not exist, and thus the ports cannot be disconnected.

13782 ILLEGAL PORT CONNECTION

The connection between the ports of plug-in units is not allowed.

13783 PORT CONNECTION DATA DOES NOT EXIST

The connection data between two ports does not exist, and thus it cannot be read from equipment database.

13784 INTERNAL ERROR IN EQCPRO PROCESS

An internal error has happened in EQCPRO process.

13785 FAULTY OPERATION USED

A faulty operation has been used in communication between EQCPRO and other processes.

13786 ILLEGAL DB PARAMETER VALUE USED

An illegal parameter has been used in communication between equip-ment database and some other process.

13787 ILLEGAL SEARCH KEY COMBINATION USED

An illegal search key combination has been used when retrieving data from equipment database.

13788 ROUTING TABLE CANNOT BE OPENED

Routing table cannot be opened

13789 INTERRUPTING IS NOT ALLOWED

Interrupting the active test is not allowed. Try again later.

Page 300: DX Error Messages

300 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

13790 FILE DELETION NOT ALLOWED

File deletion is not allowed because destination build is created in SOMAFI file.

13791 MAFILE CORRESPONDING TO CDID NOT FOUND

The MAFILE corresponding to change delivery identification is not found.

13792 DELETING OF SCMANA DIRECTORY IS NOT ALLOWED

Deleting of SCMANA directory is not allowed.

13793 NOT A CENTREX SERVICE NUMBER

Centrex is not a centrex service number.

13794 MAXIMUM NUMBER OF TRUNCATED NUMBERS EXCEEDED

Maximum number of truncated numbers allowed in the KIDATA database exceeded.

13795 THERE EXISTS A SUBSCRIBER IN THE TRUNCATED NUMBERS VALUE RANGE

There exists a subscriber in KIDATA database that belongs to the value range of the truncated number being added.

13796 SUBSCRIBER BELONGS TO THE VALUE RANGE OF A TRUN-CATED NUMBER

Subscriber being added belongs to the value range of an existing trun-cated number in KIDATA database.

13797 AT PRESENT ANOTHER SESSION IS ACTIVE

At present another session is active, so current service has to be repeated later

13798 PARAMETER TARGET_ID IS INVALID

Parameter target_id is invalid ( points to a DXT which does not exist )

13799 PARAMETER PRI_ROUTE IS INVALID

Parameter pri_route is invalid ( points to a DXT which does not exist )

13800 PARAMETER SEC_ROUTE IS INVALID

Parameter sec_route is invalid ( points to a DXT which does not exist )

13801 WRITING INTO ROUTING TABLE WAS UNSUCCESSFUL

Writing into routing table was unsuccessful

13802 ROUTING TABLE IS UPDATED/READ BUT CAN NOT BE CLOSED

Routing table is updated/read but can not be closed

13803 PRIMARY DISTANCE ( GIVEN IN PRI_DIST ) IS OUT OF RANGE

Primary distance ( given in pri_dist ) is out of range

13804 SECONDARY DISTANCE ( GIVEN IN SEC_DIST ) IS OUT OF RANGE

Secondary distance ( given in sec_dist ) is out of range

13805 RECORD IN ROUTING TABLE CAN NOT BE DELETED

Record in routing table can not be deleted

13806 RECORD IN ROUTING TABLE CAN NOT BE READ

Page 301: DX Error Messages

DN987378Issue 24-0

301

General Error Messages of System DX error messages

Id:0900d8058077e097

Record in routing table can not be read

13807 DATABASE READING WAS NOT SUCCESSFUL

Database reading was NOT successful ( during reading all DXT IDs which are in network )

13808 DBP DB NOT FOUND

The database record is not found from DBPARA.

13809 DBP ERRONEOUS RECORD LENGTH

The record length of DBPARA is erroneous.

13810 RESPONSE TO A THRESHOLD QUERY

This is a response to a threshold query made to AIMPRB.

13811 REQUESTED THRESHOLD IS NOT SET

Cannot answer to query because the requested threshold is not set.

13812 SUCCESSFULLY UPDATED

The threshold values are successfully updated.

13813 THRESHOLD IS NOT SET

The threshold specified in this message is not set.

13814 VPLTP OR VCLTP ALLOCATION IS REJECTED BECAUSE OF LACK OF UNALLOCATED CELL BUFFER CAPACITY

VPLtp or VCLtp allocation is rejected because of the lack of unallocated cell buffer capacity

13815 ALLOCATION IS REJECTED BECAUSE OF LACK OF BANDWIDTH OR TOO STRICT DELAY REQUIREMENTS

Allocation is rejected because of the lack of unallocated bandwidth or too strict delay requirements.

13816 REQUESTED SERVICE CATEGORY FOR VCLTP IS NOT SUP-PORTED IN THE VPCTP (FOR VCCS)

Requested service category for VCLtp is not supported in the VPCtp (for VCCs)

13817 NUMBER OF VPC AND/OR VCC CONNECTIONS WITHIN INTER-FACE IS EXCEEDING THE SET LIMITS

VPC or VCC connection rejected because of the number of VPC and/or VCC connections within interface is exceeding the set limits.

13818 THE NUMBER OF VCC CONNECTIONS WITHIN VPLTP IS EXCEED-ING THE SET LIMITS

VCC connection rejected because of the number of VCC connections within VPLtp is exceeding the set limits.

13819 CAC HAS FOUND WRONG PARAMETERS IN THE INCOMING SERVICE REQUEST

CAC has found wrong parameter(s) in the incoming service request. Error code is used as a general indication of the wrong paramenters in the received message.

13820 GENERAL HIGH LEVEL CAC ERROR CODE

Page 302: DX Error Messages

302 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

A general high level CAC error code.

13821 GENERAL LOW LEVEL CAC ERROR CODE

A general low level CAC error code.

13825 THE INPUT IS NOT HANDLED IN THIS SYM UNIT

Recovery does not handle the input in this active/passive SYM unit.

13826 THERE ARE NO ONGOING TESTS

There is no test active in the BSC.

13828 ATTEMPTING TO DELETE RUNNING BUILD

Destination build cannot be deleted, because it is running in some or in all computer units.

13829 ATTEMPT TO DELETE BUILD ONLY FROM OMU

It is not allowed to delete build from OMU if it still exists in some other disk units SOMAFI

13830 IT SEEMS THAT DIRECTORY IS NOT BUILD DIRECTORY (THERE IS NOT LFILES SUBDIRECTORY)

This is warning notification: there is not LFILES subdirectory under given directory.

13831 IT IS NOT ALLOWED TO DELETE BUILD THAT HAS STATUS BU

It is not allowed to delete build that has status BU. Check if build is correct one or change statuses.

13832 IT IS NOT ALLOWED TO DELETE DEFAULT BUILD

It is not allowed to delete default build. Check if build is correct or change default build information.

13833 ACTIVE INFO OF BUILD IN DIFFERENT SOMAFI FILES CONFLICTS

Active information of build between different SOMAFI files in disk units is conflicting.

13834 ONLY ACTIVE BUILD IN DIRECTORY CANNOT BE DELETED

Only active build in directory cannot be deleted, whereas both builds can be deleted at the same time (if this is otherwise allowed).

13835 DIRECTORY BASED DELETING IS NOT ALLOWED IN THESE CON-DITIONS

Directory based deleting is not allowed. Try some other parameter com-bination.

13836 MAFILE BASED DELETING IS NOT ALLOWED IN THESE CONDI-TIONS

MAFILE based deleting is not allowed in these conditions. It is possible that a suitable MAFILE is not available or the er combination and the d configuration do not match. Try some other parameter combination.

13837 BUILD CONFIGURATION IN NETWORK ELEMENT IS NOT LEGAL

Build configuration in network element (between different disk units) is not legal. Deleting of builds is not safe in these conditions.

Page 303: DX Error Messages

DN987378Issue 24-0

303

General Error Messages of System DX error messages

Id:0900d8058077e097

13838 GIVEN UNIT IS NOT UNDER SOFTWARE CONFIGURATION MAN-AGEMENT

Given unit is not under SW configuration management.

13839 DISK UPDATING IS IN PROGRESS

When RXEPRB program block receives the message save_scd_to_disk_s with save_mode_t_normal_c, the user is immedi-ately acknowledged with this status.

13842 AC ACCESS CHANNEL CANT BE USED AS TELECOM OR O&M LINK

AC (AutoConfiguration) Access Channel can not be used as telecom or O&Mlink

13844 VPCTP DOESNT HAVE ENOUGH CAPACITY FOR VCLTPS

VPCtp does not have enough capacity for VCLtps.

13846 NO RESPONSE FROM SERVICE PROVIDER

No acknowledgement was received from the service provider within timeout limit.

13850 STARTING OF A FAMILY FAILED IN A PREPROCESSOR

Starting of a process family failed in a preprocessor unit.

13851 FAMILY SUPERVISION ERROR IN A PREPROCESSOR

Supervision of a process family failed in a preprocessor unit.

13852 INCALL AND/OR CRN IS LINKED TO THE CENTREX GROUP

An Incall number and/or Call Return number is linked to the centrex group.

13853 LOGICAL MULTICAST NOT SUPPORTED

Logical multicast is not supported in the system.

13854 THE POINTED CONNECTION IS NOT ON VP-LEVEL

An attempt has been made to point to a vc-level connection when the used routine is intended to be used with vp-level connections

13856 NO SWITCH INFO EXISTS

There is no stored switch info in the system

13857 PERMANENT INDEX OUT OF THE RANGE RESERVED FOR THE SPECIFIC OBJECT TYPE

The permanent index value used to point to an object was not within the range reserved for the object type

13858 LOCAL INDEX OUT OF THE RANGE RESERVED FOR THE SPECIFIC OBJECT TYPE

The local index value used to point to an object was not within the range reserved for the object type

13860 INVALID TETRA AUTHENTICATION ALGORITHM VERSION

The given TETRA authentication algorithm version is invalid.

13861 INVALID VALUE RANGE DEFINITION

Page 304: DX Error Messages

304 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The range definition is invalid, for example minimum value may exceed maximum.

13862 THE TERMINATION POINTS TO BE CONNECTED ARE THE ONE AND SAME TERMINATION POINT

The identifiers of the two termination points to be connected point to the same record in the database. The connection can not be created.

13863 THE UNIT STATE OF TDSC IS NOT WO-EX

the state of the TDSC functional unit is not WO-EX.

13864 FORBIDDEN MMI USER PASSWORD

The given password is not allowed to be used as MMI password.

13865 COMPUTER RESTART TIME-OUT

Computer restart has not completed in predefined time.

13866 SPECIFIED ORG IS SPECIAL ORG

specified org is special org

13867 THERE IS NO MASTER DXT IN THE SUBNET

There is no master dxt in the subnet.

13868 SUBNET NOT FOUND

no subnet associated with given dxt or with given dynamic address

13869 NO IP SERVICE

ip service not allowed

13870 NO DYNAMIC ADDRESS PAIRS FOR AN ORGANIZATION

an organization does not have address pool where saves ip dynamic address pairs

13871 NUMBER OF ADDRESS PAIRS REACHES MAXIMUM, CANNOT ADD ANY

the number of address pairs reaches the max, cannot add any more.

13872 CANNOT FIND GIVEN STATIC OR DYNAMIC IP ADDRESS

cannot find given static address or dynamic address pairs which should be modified

13873 CANNOT ADD MORE DXTS, DXT LIMIT EXCEEDED

the number of DXT in a subnet exceeded, cannot add DXT to it.

13874 MEMBER DXT STILL EXISTS

there is at least one member DXT in the subnet, cannot delete master DXT.

13875 INVALID IP ADDRESS

invalid ip address

13876 THE CONVERSION RECORD IS NOT IN THE CHAIN

THE CONVERSION RECORD IS NOT IN THE CHAIN

13877 CNEFIL CORRUPTED

CNEFIL CORRUPTED

13878 PIGPRB IS NOT READY TO PROVIDE THE REQUESTED SERVICE

Page 305: DX Error Messages

DN987378Issue 24-0

305

General Error Messages of System DX error messages

Id:0900d8058077e097

This error is received when services are requested when PIGPRB is not ready to serve. One example of this kind of situation is when service request arrives when PIGPRB initialization is still continuing after startup, in this case repeating the request later may help.

13879 THE PROVIDER OF THE SERVICE REQUESTED IS NOT READY TO SERVE THE REQUEST

The service provider is not ready to perform the requested service. Try again later.

14109 INVALID KEY FLAG VALUE

The value for the key flag is incorrect.

14111 VPI RANGE IS NOT FREE

There is at least one VPLtp in the specified VPI range. Specify a differ-ent range or remove the existing VPLtps in the range.

14114 CONFIGURATION FAILURE OF A PREPROCESSOR

There is a configuration failure of a preprocessor.

14115 STARTUP TIMEOUT OF A PREPROCESSOR

The startup of a preprocessor takes too long a time.

14116 ILLEGAL ROGLIB LIBRARY FUNCTION CALL IN THIS COMPUTER UNIT

There are different ROGLIB libraries for different prosessor units. All-ROGLIB services are not implemented in every ROGLIB library. This errorcode is returned when the program calls a ROGLIB library function illegal in the unit.

14118 SERVICE IS RESERVED

Remote backup transfer is reserved, transfer or fallback is in progress.

14119 DIRECTORY THAT SHOULD NOT EXIST IS FOUND

Directory that is tried to create already exists. Directory must be deleted or renamed if transfer service is used.

14120 TRANSFER SERVICE HAS NOT BEEN ASKED

Readiness of transfer is asked even though preparation have not been asked.

14121 SYSTEM IS NOT READY FOR TRANSFER

System has not done all needed preparation to transfer.

14122 THERE IS NO TRANSFER LIST IN FB BUILDS DIRECTORY

Transfer list can not be found from FB builds SCMANA directory.

14123 TRANSFER SERVICE CAN NOT BE STARTED

Conditions for starting transfer service do not come true.

14124 COMPRESSION SERVICE HAS RETURNED AN ERROR

Error occured in compression service.

14128 DISK UNIT WORKING STATE HAVE CHANGED

Configuration of units with disks is changed after last FULL fallback copy. DATA or ARCHIVE fallback copying could not be executed

Page 306: DX Error Messages

306 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

because last FULL fallback copy was done when different disk units were in WO-EX states. Working state of unit with disks is changed, a new unit with disks is created or a unit with disks is removed. FULL fallback copying has to be done next.

14129 ROUTING AREA NOT FOUND FROM RNW DATABASE

Routing Area for the given routing area identification is not found from RNW database (BSDATA).

14130 ROUTING AREA ID ALREADY IN USE

A Routing Area Identification must be unique in the BSC.

14131 INVALID MMI USER

MMI user has been detected to be invalid for the purpose at issue.

14132 ILLEGAL TYPE OF VCC

Illegal or unknown type of the vcc. The service request is rejected.

14133 TRX CAN NOT BE SUPER-REUSED AND E-TRX OR S-TRX SIMUL-TANEOUSLY

TRX CAN NOT BE SUPER-REUSED AND E-TRX OR S-TRX SIMUL-TANEOUSLY

14134 TRX CAN NOT BE FLOATING AND EXTENDED SIMULTANEOUSLY

TRX cannot be floating and extended simultaneously.

14135 UNKNOWN CHORUS ERROR CODE

Chorus to DMX error code conversion routine received an invalid Chorus error code.

14136 UNKNOWN ERROR RETURNED BY KERNEL

Unknown error returned by kernel.

14137 SITE NOT REACHABLE

Site not reachable.

14138 SYSTEM CALL NOT IMPLEMENTED

System call not implemented.

14139 SYSTEM CALL NOT SUPPORTED

System call not supported.

14140 UNKNOWN ERROR RETURNED BY IO SERVER

Unknown error returned by IO server.

14141 ERROR WHILE DELETING NETWORK USER

The network operation access control manager could not delete network user. Use commands in IO-command group to delete network user or to get more information.

14142 NO RECORDS FOUND WITH GIVEN LAC IN DATABASE

No records were found in the database with the given location area code.

14143 RECORD WITH GIVEN SGSN_CELL_ID FOUND IN LAC AND CELL OBJECT COLLECTIONS IN THE DATABASE

Page 307: DX Error Messages

DN987378Issue 24-0

307

General Error Messages of System DX error messages

Id:0900d8058077e097

An attempt was made to create LAC and CELL objects that already exist in the database.

14144 NO RECORDS FOUND WITH GIVEN NSEI IN NSE OBJECT COL-LECTION

No records were found with the given network service entity identifier in the NSE object collection.

14145 RECORD WITH GIVEN NSEI AND BVCI FOUND IN NSE AND CELL OBJECT COLLECTIONS IN DATABASE

An attempt was made to create NSE and CELL objects that already exist in the database.

14146 LACS WITH CELLS FOUND FOR GIVEN VLR IN LAC AND CELL OBJECT COLLECTIONS IN DATABASE

The requested operation is not allowed because LACs with CELLs for the given VLR are found in LAC and CELL object collections.

14147 LAC IS ALREADY ASSOCIATED WITH ANOTHER VLR

The requested operation is not allowed, because the given LAC already exists in the database, associated with another VLR.

14148 NO CELLS FOUND WITH GIVEN KEY VALUE(S) OR OBJECT NUMBER VALUE IN DATABASE

No cells were found with the given key value(s) or object number value.

14149 A PLMN OBJECT ALREADY DEFINED AS HOME PLMN FOUND IN DATABASE

Only one PLMN object can be defined as "Home PLMN".

14150 GRSLIB CALL IS NOT ALLOWED IN UNIT

An attempt was made to call the GRSLIB library in a unit where it is not allowed.

14151 NO MORE KEYS AVAILABLE

The key table is full, no keys can be created.

14152 OUT OF RESOURCES

The kernel has been unable to perform the call because of resource exhaustion.

14153 INVALID PRIVATE DATA ARGUMENT

An invalid argument has been given.

14154 CANNOT CONNECT TO SERVER

The Private Data Manager is not accessible.

14155 CALLED FROM USER MODE

Called from user mode.

14156 FILE END MARK NOT FOUND

The end mark of the file is not found.

14163 CHANGING OF ARFCN IS NOT ALLOWED IN BACKGROUND SWAPPING WHEN TRX IS WAITING FOR APP

Page 308: DX Error Messages

308 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

If the value of TRX FREQ (ARFCN) parameter is "not used", the TRX is waiting for Automatic PicoCell Parameterization (APP), and the value cannot be changed in the background loading of the radio network plan.

14164 WRONG MESSAGE RECEIVED

Message that was not expected has been received.

14166 GPRS AND EDGE FEATURES ARE NOT IN USE IN BSC

GPRS and EDGE features are not in use in BSC.

14168 PRIVATE-DATA CALL SUCCESSFUL

PRIVATE-DATA call successful.

14169 REQUIRED TOPOLOGY DATA ARE MISSING

The internal network topology can not be build due to inconsistent internal data or missing pids (process identificators)

14170 INVALID CIRCUIT GROUP NAME

Circuit group name is not given.

14171 PARAMETER CHECKING FAILED

Checking of parameter failed.

14172 INVALID CIRCUIT FORMAT

Invalid circuit format.

14173 INVALID CALL CONTROL PARAMETER SET

Invalid call control parameter set.

14174 INVALID DUAL SEIZURE PREVENTION METHOD

Invalid dual seizure prevention method.

14175 INVALID PARAMETER HUNTED

Invalid parameter hunted.

14176 SWITCHING DATA UPDATE FAILED

Switching data update failed.

14177 THRESHOLD 2 IS BIGGER THAN THRESHOLD 1

Threshold 2 is bigger than threshold 1.

14178 CIRCUIT GROUP NAME AND NUMBER DO NOT MATCH

Circuit group name and number refer to different circuit groups.

14179 NO CIRCUITS GIVEN

No circuits given.

14180 INVALID PCM NUMBER

Invalid PCM number given.

14181 INVALID CCSPCM

Invalid ccspcm given.

14182 PCM DEFINED TO OTHER CCSPCM

PCM already defined to other ccspcm.

14183 INVALID D-CHANNEL SYSTEM

Invalid D-channel system.

Page 309: DX Error Messages

DN987378Issue 24-0

309

General Error Messages of System DX error messages

Id:0900d8058077e097

14184 CIRCUIT IDENTIFICATION CODE VALUE TOO BIG

Too big a circuit identification code value.

14185 INVALID TREE

Invalid analysis tree given.

14186 NETWORK AND LINE SIGNALLING DO NOT MATCH

Given network and line signalling do not match.

14187 INVALID NETWORK

Invalid network given.

14188 WRONG TYPE OF TRANSCODER

Wrong type of transcoder.

14190 PBX SUPPLEMENTARY SERVICES

The circuit group has supplementary services and cannot be deleted before the services are removed.

14191 CIRCUIT COUNTERS ON

Circuit(s) in circuit group has counters on.

14192 INVALID NUMBER OF PCMS

Invalid number of PCMs.

14193 INVALID NUMBER OF CIRCUITS

Invalid number of circuits.

14194 INVALID CIRCUIT IDENTIFICATION CODE

Invalid circuit identification code.

14195 INCORRECT FREQUENCY FOR A TRX WHEN UNLOCKING IS ATTEMPTED

When the unlocking of a TRX is attempted and the frequency is incor-rect,the unlocking will not be acknowledged by ABIPRB.

14196 INVALID VALUE IN FIELD FREE_RESERV

Value of field free_reserv out of range.

14197 INVALID NUMBER OF CIRCUIT IDENTIFICATION CODES

Invalid number of circuit identification codes.

14198 PXADMI BUSY

The program block PXADMI is not capable of receiving new tasks. Try again later.

14204 APP OPTION IS NOT IN USE IN BSC

This error code OPTION_APP_NOT_IN_USE_EC (Automatic PicoCell Parametrisation) indicates that the option is not in use in BSC.

14205 UNKNOWN ERROR CODE

The argument given to an error code conversion function in CXELIB is not one of the valid error code numbers in ChorusOS.

14206 THE SITE TYPE DOES NOT ALLOW SYNCHRONISATION

The site type of adjacent cell BTS or this cell BTS does not allow syn-chronisation between adjacent cell and the cell in use. The user cannot

Page 310: DX Error Messages

310 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

give the value Y to the SYNC parameter when creating or modifying an adjacent cell if the site type of BTS does not support synchronisation between cells.

14207 THE RECORD WAS ONLY PARTLY READ/WRITTEN

The filesystem read/wrote only part of a record

14208 MAXIMUM NUMBER OF HTTP SESSIONS FROM SAME USER EXCEEDED

Maximum number of HTTP sessions from one user has exceed.

14211 O&M OR TRX LINK CIRCUITS RESERVATION BACK TO THE POOL FAILED

Reservation of the O&M or TRX link circuits back to the pool has failed.

14212 SPEECH CIRCUITS RESERVATION BACK TO THE POOL FAILED

Reservation of the speech circuits back to the pool has failed.

14213 TRX LINK AND TRX SPEECH CIRCUITS RESERVATION BACK TO THE POOL FAILED

Reservation of the TRX link and TRX speech circuits back to the pool has failed.

14215 DEFINED PROFILE NOT FOUND

Data profile attached to subscriber is not found or data profile does not exist in the database.

14216 DEFINED PROFILE ALREADY EXISTS

Defined profile already exists in database.

14222 THE MAXIMUM NUMBER OF NS-VC/NS-VL IN THE NSE EXCEEDED

The maximum number of Network Service Virtual Connection (NS-VC) in the Network Service Entity (NSE) is exceeded

14223 DELETION OF THE LAST NS-VC OF NSE USED BY GPRS-ENABLED BTS IS NOT POSSIBLE

Deletion of the last ns-vc of nse used by GPRS-enabled BTS is not pos-sible.

14224 NAME OF NS-VC IS ILLEGAL

The name of NS-VC may consist of allowed characters only.

14225 THE NAME OF NS-VC IS ALREADY IN USE IN THE BSC

The name of NS-VC must be unique in the BSC.

14226 NS-VC OBJECT NOT FOUND IN DATABASE

NS-VC object was not found in the radio network database.

14227 TERMINATION POINT IS PRERESERVED

Termination point is prereserved. The requested operation is not allowed to this termination point.

14228 GPRS IS ENABLED IN THE CELL

General Packet Radio System function is in active state in the cell.

14229 NO RECORDS FOUND WITH GIVEN TERMS IN NSE OBJECT COL-LECTION

Page 311: DX Error Messages

DN987378Issue 24-0

311

General Error Messages of System DX error messages

Id:0900d8058077e097

No records found with given terms in NSE object collection.

14230 CONTROL CHANNEL RELEASE DISALLOWED

Control channel release is not allowed. The protocol state inside the control channel prohibits release. Try again release with an override parameter if you are absolutely sure that the channel can be released despite of the protocol state.

14231 NSE OF NS-VC HAS DIFFERENT PACKET CONTROL UNIT ADDRESS IN DATABASE

There exists already an NSE with the same NSEI but different Packet Control Unit Address in the radio network database.

14232 ADDRESS OF PCU IS ALREADY USED BY OTHER NSE

Address of Packet Control Unit is already used by some other NSE with another NSEI

14233 NS-VCS FOUND FOR GIVEN NSEI IN NS-VC OBJECT COLLEC-TION

The requested operation is not allowed because the NS-VCs associ-ated with the given NSEI are found in NS-VC object collection.

14234 CELLS FOUND FOR GIVEN NSEI IN CELL OBJECT COLLECTION

The requested operation is not allowed because CELLs associated with the given NSEI are found in CELL object collection.

14235 SHADOWS TRANSACTION IS READ-ONLY

An attempt was made to make some form of update operation in the Shadows database engine using a read-only transaction. Likely caused by a transaction started on a snapshot.

14239 HEADING TOO LONG

Given data exceeds maximum length of heading.

14240 CHANNEL FINDER OPTION IS NOT IN USE IN BSC

The Channel Finder option is not in use in the BSC. The Channel Finder registers statistics on cells which have not been defined as adjacent cells but which are among those six neighbouring cells, that the MS receives best.

14241 DB VALUE IS INCORRECT

The DB-value is incorrect. DB-value is out of range or DB1 is bigger than DB2 or DB-values are same.

14242 NS-VC DOES NOT EXIST

The Network Service Virtual Connection does not exist.

14243 NSEI DOES NOT EXIST

The Network Service Entity Identifier does not exist.

14244 NS-VCI ALREADY EXISTS

The Network Service Virtual Connection Identifier already exists.

14245 NS-VC NAME ALREADY EXISTS

The name of the Network Service Virtual Connection already exists.

Page 312: DX Error Messages

312 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14246 NO FREE NS-VC AVAILABLE IN NSE

All NS-VCs of the NSE are already in use.

14247 NS-VC NOT LOCKED

The Network Service Virtual Connection has not been locked.

14248 NS-VC ALREADY LOCKED

The Network Service Virtual Connection is already locked.

14249 NS-VC ALREADY UNLOCKED

The Network Service Virtual Connection is already unlocked.

14250 NS OPERATION FINISHED

The Network Service specific operation is finished.

14251 PAPU ADDRESSES NOT IDENTICAL IN NSE AND BEARER

PAPUs logical unit addresses are not identical with each other in the created NSE and in the bearer channel.

14252 NO RESPONSE FROM FRADMI

No response has been received from the FRADMI process.

14253 NO RESPONSE FROM GGBPRB

No response has been received from the GGBPRB program block.

14254 CIRS SUM IS GREATER THAN ACCESS RATE

The sum of committed information rates of virtual circuits is greater than the access rate of the bearer channel.

14256 THE FILE IS NOT A VALID COMPRESSION ARCHIVE

The file in question is not a compression archive or is a corrupted archive.

14257 THE FILES DO NOT FIT INTO THE ARCHIVE WITH THE GIVEN ALLOCATION RATIO

The files cannot be compressed enough to fit into the archive with the given allocation ratio. Use a bigger ratio.

14258 THE SETTING OF FTAM ATTRIBUTES OF THE ARCHIVE HAS FAILED

The setting of FTAM attributes of the archive has failed. However, a valid compression archive was created.

14259 SOME OF THE RQUIRED FILES FILES WERE NOT HANDLED PROPERLY

When compressing a list of files, some of the given files could not be accessed. However, a valid compression archive consisting of the accessable files was created. When decompressing files, some of the requested files could not be decompressed, but the rest of the files were successfully decompressed.

14260 TARGET OF THE OPERATION HAS NO DEFINED OPERATING STATE

The target of the operation has no defined operating state and therefore e.g state inquiry cannot return the state.

Page 313: DX Error Messages

DN987378Issue 24-0

313

General Error Messages of System DX error messages

Id:0900d8058077e097

14261 DEVICE ACCESS IS DENIED

The device is not accessible due to operating state or insufficient per-mission.

14262 INVALID OPERATING STATE

The target is in a wrong operating state or you have tried to change it to a wrong operating state.

14263 THE I/O UNIT STATE MANAGEMENT NOT READY

The I/O unit operating state management is not ready. It has not yet successfully initialized.

14264 I/O DEVICE INDEX OUT OF RANGE

The device index of I/O unit exceeds the max index value.

14265 I/O DEVICE ALREADY EXISTS

The I/O unit has been already created.

14266 MMI PROFILE DOES NOT EXIST

The MMI profile does not exist.

14267 MEASUREMENT NOT STOPPED

The measurement has not been stopped.

14268 ERROR IN MEASUREMENT INTERVALS

Operation failed, error in measurement intervals.

14269 ILLEGAL BTS CONFIGURATION

Illegal BTS configuration (general cause value).

14270 NOT ALL MANDATORY SYSTEM INFORMATION MESSAGES ARE RECEIVED BY TRX

TRX has not received all mandatory system information messages.

14271 A SHADOWS DATABASE PAGE WAS NOT FOUND

Shadows internal error code. Indicates that a requested page was not found in a page table or in a snapshot. Encountered only as a result of a programming error within Shadows.

14272 UKNOWN SHADOWS PAGE SIZE SPECIFIED

Shadows internal error. Indicates that an unknown page size was spec-ified. Encountered only as a result of a programming error within Shadows.

14273 SHADOWS CACHE IS FULL

The Shadows cache is full.

14274 SHADOWS TRANSACTION EXCEEDED ITS MAXIMUM UPDATE LIMIT

A Shadows transaction exceeded its maximum number of updates.

14275 NEXT SHADOWS COMMIT BATCH IS FULL

The next Shadows commit batch is full.

14276 NO FREE SHADOWS TRANSACTIONS

There are no free Shadows transactions available.

Page 314: DX Error Messages

314 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14277 ILLEGAL INITIALIZATION VALUE FOR CCCH_CONF IN SYTEM INFORMATION MESSAGE TYPE 3

Illegal initialization value for CCCH_CONF in system information type 3.

14278 ILLEGAL INITIALIZATION VALUE FOR WHERE-FIELD IN SYSTEM INFORMATION MESSAGE TYPE 3

Illegal initialization value for WHERE-field in system information type 3.

14281 CONFLICT BETWEEN THE MAPPING OF SI13 AND BCCH-EXT SIS

Conflict between the mapping of system information type 13 and BCCH-ext system information types.

14282 ILLEGAL INITIALIZATION VALUE FOR DRX_TIMER_MAX FIELD IN SYSTEM INFORMATION TYPE 13

Illegal initialization value for DRX_TIMER_MAX field in system informa-tion type 13.

14283 ILLEGAL INITIALIZATION VALUE FOR ACC_BURST_TYPE IN SYSTEM INFORMATION TYPE 13

Illegal initialization value for ACC_BURST_TYPE in system information type 13.

14284 THE VALUE OF BS_AG_BLKS_RES CANNOT BE CHANGED

The value of BS_AG_BLKS_RES cannot be changed at run time.

14285 THE VALUE OF BS_PA_MFRMS CANNOT BE CHANGED

The value of BS_PA_MFRMS cannot be changed at runtime.

14286 THE VALUE OF CCCH_CONF CANNOT BE CHANGED AT RUNTIME

The value of CCCH_CONF cannot be changed at runtime.

14287 SI13_PBCCH_LOCATION CANNOT BE CHANGED IN SYSTEM INFORMATION TYPE 3 AND 4

SI13_PBCCH_LOCATION cannot be changed in system information type 3 or 4at runtime.

14288 BCCH-EXT CANNOT BE CREATED

BCCH-ext cannot be created at runtime.

14289 BCCH-EXT CANNOT BE RELEASED

BCCH-ext cannot be released at runtime.

14290 THE VALUE OF DRX_TIMER_MAX CANNOT BE CHANGED

The value of DRX_TIMER_MAX cannot be changed at runtime.

14291 THE VALUE ACC_BURST_TYPE CANNOT BE CHANGED

The value ACC_BURST_TYPE cannot be changed at runtime.

14292 UNKNOWN COMPUTER UNIT FOR CONTROL CHANNEL

Computer unit for control channel is given but computer unit is not found or service provider on this computer is not found. Select another computer unit and try again.

14298 D-CHANNEL ACTIVATION NOT DENIED

The D-channel was not set into state "Activation denied" before the deletion or modification of the signalling channel was attempted.

Page 315: DX Error Messages

DN987378Issue 24-0

315

General Error Messages of System DX error messages

Id:0900d8058077e097

14299 CRC ERROR IN A COMPRESSED FILE

At least one of the files in the compression archive has a CRC error. This means that the compression archive might be corrupted and should be dealt with caution.

14303 PACKING OF DISK PARTLY SUCCESSFUL

The packing of the disk was partly successful, some fragments were removed from the disk.

14304 DISK ALREADY PACKED

The disk was already packed, there were no fragments in it.

14305 DISK PACKING FAILED

The packing of the disk was unsuccessful. No fragments were removed from the disk.

14306 DBL ERROR IN LOGBUFFER

There is an error in logbuffer.

14307 DBL- NO MORE TRANSACTIONS

There are no more transaction in the logbuffer.

14308 DBL - NO MORE UPDATES

There are no more updates in the transaction.

14309 GIVEN COMBINATION OF PCU ADDRESS AND PCU INDEX NOT FOUND FROM RNW DATABASE

Given combination of logical address of BCSU where the Packet Control Unit is located and the PIU index of Packet Control Unit not found from Radio Network Database.

14310 COMMITTEDINFORATE IS NOT ONLY ATTRIBUTE TO BE MODIFIED

The user tries to modify CommittedInfoRate and other attributes at the same time

14311 MAX NUMBER OF NSE FOR PAPU ALREADY CREATED

The maximum number of NSEs for one PAPU is already created.

14312 LACS NOT RELATED TO GIVEN VLR

No location area codes have been associated with the given MSC/VLR.

14313 RA OR NSE IS WRONGLY CONFIGURED IN THE BSS

Either the routing area of the cell or the association between the routing area and the network service entity is wrongly configured in the BSS.

14314 RA OF CELL IS SERVED BY DIFFERENT PAPU

The routing area of the cell is served by a different Packet Processing Unit.

14315 NSE CONFIGURATION ERROR

The Network Service Entity is configured to another Packet Processing Unit.

14316 VLR DOES NOT EXIST

The MSC/VLR does not exist.

Page 316: DX Error Messages

316 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14317 NO RESPONSE FROM GMGPRB

No response has been received from the GMGPRB.

14318 NO RESPONSE FROM GSPPRB

No response has been received from the GSPPRB.

14319 NO RESPONSE FROM GS1PRB

No response has been received from the GS1PRB.

14320 NO RESPONSE FROM GIPPRB

No response has been received from the GIPPRB.

14321 NO RESPONSE FROM GTPPRB

No response has been received from the GTPPRB.

14322 NO RESPONSE FROM GDCPRB

No response has been received from the GDCPRB.

14323 NO RESPONSE FROM GRNPRB

No response has been received from the GRNPRB.

14324 COMMUNICATION ERROR WITH SSCOP

Response message is not received from the SSCOP.

14325 ANALYSIS LEADS TO TIME CONTROLLED ROUTING

Digit analysis leads to time controlled routing. The analysis cannot ber-emoved, unless time controlled routing is deleted first.

14327 DBL NOT PASSED FIRST TRANSACTION

The first transaction has not been passed.

14329 DBL NOT PASSED FIRST UPDATE

The first update has not been passed.

14330 NETWORK SERVICE ENTITY IS IN USE IN A CELL

Network service entity is used in a cell or cells by some BTS or BTSs.

14332 MAXIMUM NUMBER OF SUBSCRIPTIONS EXCEEDED

The upper limit for the number of subscriptions has been reached. No more subscriptions can be placed until some are removed.

14333 NUMBER OF LACS EXCEEDS THE NUMBER ALLOWED FOR ONE VLR

An attempt was made to create more LACs than allowed in association with one VLR.

14334 BVCI DOES NOT EXIST

The BSSGP virtual connection identifier is unknown.

14335 THERE IS NO UNBLOCKED NS-VC IN THE NSE

All NS-VCs of the NSE are blocked. The NSE cannot handle packet data.

14336 BVC ALREADY EXISTS IN THE SYSTEM

The BSSGB virtual connection already exists in the system.

14337 BVC DOES NOT BELONG IN THIS BLOCK

Page 317: DX Error Messages

DN987378Issue 24-0

317

General Error Messages of System DX error messages

Id:0900d8058077e097

The BSSGP virtual connection does not belong in this block in the BVCSTA file. It is not configured to the NSE.

14338 SOME MISMATCH IN GIVEN TRIGGERING CONDITIONS

There are some mismatching values in given triggering conditions.

14339 NSE IS FULL, NO ROOM FOR NEW BVC

The maximum number of BSSGP virtual connections has been exceeded. There is no room for a new BVC in the NSE.

14340 D-CHANNEL ACTIVATION FAILED

D-channel activation failed.

14341 D-CHANNEL BLOCKING FAILED

D-channel blocking failed.

14342 D-CHANNEL STATE CHANGE ALREADY ACTIVATED

D-channel state change already activated.

14343 D-CHANNEL STATE CHANGE NOT ALLOWED

D-channel state change not allowed.

14344 DATA MISMATCH BETWEEN PXNETM WORK FILE AND AN OTHER D-CHANNEL FILE

Data mismatch between PXNETM work file and another D-channel file.

14345 DATA MISMATCH BETWEEN PXNETM WORK FILE AND AN OTHER DLC-CHANNEL FILE

Data mismatch between PXNETM work file and another DLC-channel file.

14346 PXNETM PROGRAM BLOCK IS STARTING

The PXNETM program block is starting.

14347 CPXSAL HAD TO CREATE NEW HAND WHEN LINK WAS RESERVED WITH UPDATE PARAMETER ON

CPXSAL received a link_init_req_s message with update parameter as repair_c and could not find a hand with the same control channel iden-tifier from its tables. Thus a new hand had to be created and this error code is sent to the SSCF layer in the link_init_ack_s message.

14348 TOO MANY INDICES

Maximum number of indices reached.

14349 CONFLICTING INDICES

Conflicting indices.

14350 UNKNOWN INDEX

Unknown index.

14351 MAX NUMBER OF CELLS FOR PAPU ALREADY CREATED

The maximum number of cells for one PAPU is already created.

14352 GSTPRB IS BUSY. TRY AGAIN LATER.

GSTPRB is busy and cannot receive any messages. GSTPRB ignored your attempt so you should try again later.

Page 318: DX Error Messages

318 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14355 UNFINISHED GPDATA OPERATION EXISTS

There is an unfinished parameter handling operation going on in the GPDATA.

14356 TOO MANY ADDRESSES

Subsciber has too many addresses in database.

14357 PROFILE CONFLICT

There is no space to add given information to the profile or update infor-mation conflicts with the existing content of the profile.

14358 MAXIMUM NUMBER OF NSES EXCEEDED

There is no room for a new NSE in the system.

14359 OUTGOING CALL BARRING ANALYSIS

Handled analysis is outgoing call barring analysis

14360 CENTREX MULTINUMBER OUTGOING CALL IDENTIFICATION ANALYSIS

Handled analysis is centrex multinumber outgoing call identification analysis

14361 GIVEN ISDN PCM ALREADY EXISTS

Given ISDN PCM already exists.

14362 GIVEN ISDN PCM IS NOT FOUND

Given ISDN PCM is not found.

14363 TIMEOUT FOR LOADING A MODULE OCCURED

A timeout if the loading of a module lasts for more than 30 secs.

14364 DATA AREA FOR BLSLIB NOT FOUND

The data area reserved for BLSLIB is not found.

14365 NO UNIT FOR THE GIVEN LOAD LIST

There is no unit for the given load list in BLNAME.

14366 NO RESPONSE FROM GBNPRB

No response from GBNPRB.

14367 PCU ADDRESSES NOT IDENTICAL IN NSE AND BEARER

The NSE and the bearer channel are not located to the same PCU in the BSC.

14368 ISDN PCM CONTROL IS NOT OK

The controlling of ISDN PCM is not in order. The program block SI1PRB should be responsible for controlling the ISDN PCM.

14369 TPST UNIT IS NOT FOUND WITH THE GIVEN INDEX

TPST functional unit with the given unit index has not been defined to the exchange.

14370 SIGNALLING LINK COMMAND STOP WAS RECEIVED

Upper layer, e.g. MTP-3, sent signalling link stop command.

14371 INITIAL ALIGNMENT WAS NOT SUCCESSFUL

Connection establishment was not successful.

Page 319: DX Error Messages

DN987378Issue 24-0

319

General Error Messages of System DX error messages

Id:0900d8058077e097

14372 REMOTE USER RELEASED THE CONNECTION

Remote level 3, e.g. MTP-3, released the connection.

14373 SSCOP RELEASED THE CONNECTION

Service Specific Connection Oriented Protocol (SSCOP) released the connection.

14374 LAYER MANAGEMENT RELEASED THE CONNECTION

Layer management released the connection. The layer management can be either local or remote.

14375 PROTOCOL ERROR OCCURED IN SAAL STACK

Illegal protocol messages were received in SAAL stack.

14376 MESSAGE NOT VALID IN STATE

The received message is not valid at the current state of the receiver.

14377 ILLEGAL VALUE OF PARAMETER

One of the received parameter contained illegal value.

14378 TERMINAL ADDRESSING ERROR

Message was addressed to the wrong terminal.

14379 SIGNALLING LINK ADDRESSING ERROR

Message was sent to the wrong signalling link.

14380 NS-VC CREATION FAILED

The creation of a Network Service Virtual Connection has failed in the Gb interface.

14381 NS-VC UNBLOCK FAILED

The attempt to unblock the Network Service Virtual Connection by the user or by the system has failed in the Gb interface.

14382 BVC CREATION HAS FAILED

The creation of the BSSGP virtual connection has failed in the Gb inter-face.

14383 BVC UNBLOCK FAILED

The unblocking of the BSSGP virtual connection has failed in the Gb interface.

14384 BVC BLOCK FAILED

The blocking of the BSSGP virtual connection has failed in the Gb inter-face.

14385 BVC DELETION FAILED

The deletion of the BSSGP virtual connection has failed in the Gb inter-face.

14386 MEASURED POWER LEVEL DIFFERS TOO MUCH FROM DEFAULT

MEASURED POWER LEVEL DIFFERS TOO MUCH FROM THE DEFAULT VALUE

14387 RX BRANCHES IN IMBALANCE; OTHER BRANCH MALFUNCTION-ING

Page 320: DX Error Messages

320 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

RX branches in imbalance. Other branch is malfunctioning.

14388 TOO MUCH PHASE ERROR; SENSITIVITY NOT MEASURED

Too much phase error. Sensitivity not measured.

14390 FILE IS BEING UPDATED

RIZRDS returns this error code when it receives a write request targeted at a POSIX configuration file which is currently being updated by another process

14391 OPERATION INTERRUPTED

RIZRDS was restarted and sufficient data to restart a given task was not available.

14392 INVALID FILENAME OR PATH

The path and/or filename could not be parsed from the parameter.

14393 WRITE REQUESTS ACCEPTED FROM OMU ONLY

POSIX configuration files can only be written by process families residing in OMU.

14394 SIGNALLING ATM ADAPTATION LAYER FAILURE

Failure has occured in the internal functioning of Signalling ATM Adap-tation Layer.

14395 RESULT IS NOT WITHIN THRESHOLD VALUE RANGE

Result is not within threshold value range.

14396 NO SI_END_ACK/NACK MESSAGE FROM TRX

TRX has not responded to system information message sending.

14397 OWN PREPROCESSOR INDEX IS UNKNOWN

DMX messaging system cannot allow applications to register yet because the preprocessor index of the own computer has not been defined.

14398 CXMANA MEMORY ALLOCATION ERROR

DMX messaging subsystem manager has run out of memory, and cannot storeany more DMX identities.

14399 DYNAMIC FAMILY IDENTIFIERS EXHAUSTED

DMX messaging subsystem does not have any more dynamic family identifiers available.

14400 NO FREE PROCESS IDENTIFIER

DMX messaging cannot allocate a process id from the requested family because all available process ids are already in use.

14401 DMX MESSAGE QUEUES EXHAUSTED

All message queues provided by DMX messaging subsystem are already in use.

14402 REQUESTED DMX IDENTITY IS ALREADY IN USE

The requested DMX identity is already in use.

14403 DBL NOT AT THE FIRST TRANSACTION

Not at the first transaction

Page 321: DX Error Messages

DN987378Issue 24-0

321

General Error Messages of System DX error messages

Id:0900d8058077e097

14404 DBL NOT AT THE FIRST UPDATE

Not at the first update

14405 ACCESS NOT ALLOWED IN THE CURRENT STATE

Access to the device is not allowed in the current state.

14408 REMOVAL OF PRINTER FAILED

Removal of printer from the system failed.

14409 NO CDSU OR ET WITH EC2ET ON THIS PCM

No CDSU, NDSD, NDSM or ET with EC2ET on this PCM.

14410 PX1WRK FILE CORRUPTED

Program block can not read PX1WRK file.

14411 PX3WRK FILE CORRUPTED

Program block can not read PX3WRK file.

14412 PCM USER PART IS INCORRECT

PCM user part is incorrect.

14413 NOT SUPERVISED

Family is not supervised

14414 ALREADY SUPERVISED

Family is already supervised

14415 OBJECT REFERENCE IN TRIE DIRECTORY IS INCORRENT

Object referenced in TRIE directory was not found from the respective collection.

14416 A LOOP WAS DETECTED IN TRIE DIRECTORY

TRIE directory in inconsistent. There is a search path, that forms a loop.

14417 A QUAD NODE IN TRIE DIRECTORY HAS LESS THAN TWO CHILDREN

A TRIE directory is inconsistent. There is a quad node, that has less than two children.

14418 DELETION OF ACCESS CHANNEL IS NOT ALLOWED

Deletion of Access channel is not allowed.

14419 STATE CHANGE OF ACCESS CHANNEL IS NOT ALLOWED

State change of access channel is not allowed.

14420 MAXIMUM NUMBER OF FAILED COMMANDS REACHED

Maximum number of failed commands was reached. No more commands are allowed.

14421 UNKNOWN PLUG-IN UNIT PORT NAME

This error code is generated when hwi_port_type_by_nam_a_r is given an unknown port name

14422 UNKNOWN PLUG-IN UNIT PORT TYPE

This error code is generated when hwi_port_name_by_type_a_r gets an unknown plug-in unit port type as input parameter

Page 322: DX Error Messages

322 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14423 UNKNOWN PLUG-IN UNIT PROPERTY NAME

This error code is generated when hwi_piu_prop_type_by_nam_a_r gets an unknown plug-in unit name as input parameter

14424 UNKNOWN PLUG-IN UNIT PROPERTY TYPE

This error code is generated when hwi_piu_prop_name_by_typ_a_r gets an unknown plug-in unit property type as input parameter

14425 INCORRECT POOL ID

Id of the abis autoconfiguration pool is incorrect.

14426 INCORRECT ET-PCM

ET-PCM is incorrect.

14427 INCORRECT ET-PCM TIMESLOT

ET-PCM timeslot is incorrect.

14428 INCORRECT POOL SIZE

Size of the abis autoconfiguration pool is incorrect.

14429 ILLEGAL POINTER TO NULL WAS GIVEN

Pointer to null was given in functions input parameter that is not allowed

14430 PROLOG CONTENT NOT FOUND

Inquired prolog content could not be found.

14431 ROOT ELEMENT NOT FOUND

Content trees root element could not be found

14432 TREES ROOT ELEMENT ALREADY EXISTS

Content tree already has root element

14433 MALLOC ERROR HAPPENED

Malloc could not reserve memory

14434 ILLEGAL CONTENT TYPE

Illegal content type was given as an input parameter to the function

14435 ILLEGAL ADDED ELEMENT

illegal element was tried to add.

14437 ILLEGAL ADDED CONTENT

Conten that was tried to add was illegal

14438 ILLEGAL CURRENT CONTENT GIVEN

Current content given to function was illegal

14439 ILLEGAL PARENT CONTENT GIVEN

Parent content given to function was illegal

14440 PREVIOUSLY GIVEN CONTENT ILLEGAL

Content given to function previously was illegal

14441 PREVIOUSLY GIVEN ATTRIBUTE ILLEGAL

Illegal before attribute given to function

14442 FILE NOT FOUND

Page 323: DX Error Messages

DN987378Issue 24-0

323

General Error Messages of System DX error messages

Id:0900d8058077e097

Given file could not be found

14443 CONTENT NOT FOUND

Inquired content could not be found

14444 ATTRIBUTE NOT FOUND

Inquired attribute could not be found

14445 ILLEGAL SEARCH KEY GIVEN

Illegal search key given to function

14446 FILE COULD NOT BE OPENED

Given file could not be opened

14447 CONTENT TO BE DELETED HAS CHILD

Content that was tried to delete has child

14448 SUBTREE NOT FOUND

Tree did not contain the given subtree

14449 EXPAT PARSING ERROR

Expat could not parse the given XML document. XML document may contain errors.

14450 CONTENT HAS PARENT OR SIBLING

Content that was tried to delete has parent or sibling

14451 ILLEGAL PARSING MODE GIVEN

Given parsing mode was illegal

14452 PROLOG CONTENT HAS POINTER TO NEXT OR PREV

prolog content tried to be deleted has pointer to next or previous prolog content

14454 AN EMPTY HOME ADDRESS AREA SLOT WAS FOUND WITH AN OVERFLOW CHAIN ATTACHED TO IT

This error code is used when manipulating hash_table_t data structure if home address area is searched and an empty home address area slot is found with an overflow chain attached to it. This is actually not an error situation but the user of hash table should not use the data values of the element which was returned with this error code but to contin-uesearching the attached overflow chain, for example.

14455 ERROR IN DISK UPDATING SUBSYSTEM OF DATABASE MANAGE-MENT SYSTEM

There has been an error in disk updating subsystem of database man-agement system. The disk updating subsystem may be out of use for some reason.

14456 NO ACK TO SCDFLE DISTRIBUTION

RUXMAN did not get an acknowledgement in due time when distribut-ing the SCDFLE data.

14457 ADDRESS NOT AVAILABLE

The address is not available.

14458 EQUIPMENT DATA NOT FOUND

Page 324: DX Error Messages

324 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The HMS equipment data is not found.

14459 EQUIPMENT DATA TOO LONG

The HMS equipment data is too long.

14460 TPST UNIT WITH THE GIVEN INDEX ALREADY EXISTS

TPST functional unit already exists in the NTN database.

14461 PCM LINES HAVE ALREADY BEEN DEFINED FOR TPST

The PCM lines for TPST have already been defined in the database.

14462 TPST PCM LINES ARE NOT FOUND

The PCM lines for TPST are not found in the database.

14463 ALARM DATABASE ACCESS FAILED DURING BCF RESET

alarm database access failed during BCF reset

14464 THE HOME EXCHANGE OF THE SUBSCRIBER WAS NOT FOUND FROM THE TXDATA DATABASE

The home exchange of the subscriber was not found from the TXDATA database.

14465 THE LOCATION OF THE SUBSCRIBER IS UNKNOWN

The location of the subscriber is unknown.

14467 PXNETM BUSY

Program block PXNETM is not capable of receiving new tasks. Try again later.

14468 THE SUBSCRIBER TYPE IS INCORRECT

The subscriber type is incorrect.

14469 TRANSMISSION EQUIPMENT IS OF WRONG KIND

Given transmission equipment is of wrong kind for requested operation.

14470 EXPAT DID NOT GIVE ERROR CODE

Expat could not give error code. Either error did not happen or Expat did not have error code to the error.

14471 ILLEGAL ATTRIBUTE WAS TRIED TO DELETE

Attribute that was tried to delete contains pointers to next attribute,pre-vious attribute or element.

14472 PROLOG CONTENT HAS POINTER TO NEXT OR PREVIOS

Prolog content can not be deleted. It contains pointers to next or previous prolog content.

14473 ATTRIBUTE DID NOT CONTAIN POINTER TO ITS ELEMENT

Attribute did not contain pointer to its element. Attribute can not be removed from the element.

14475 THE SUBSCRIBER B WAS NOT FOUND IN TXDATA

The subscriber B was not found in the TXDATA database.

14476 UNKNOWN SUBSCRIBER ADDRESS TYPE

The address type of the subscriber is unknown.

14477 ERROR IN THE PARAMETER VALUES

Page 325: DX Error Messages

DN987378Issue 24-0

325

General Error Messages of System DX error messages

Id:0900d8058077e097

There are errors in the values of the parameters.

14478 PROGRAM PACKAGE IDENTIFIER NOT AVAILABLE

Program package identifier information not available in requested pre-processor.

14479 RESERVATION OF TERMINAL FUNCTION FAILED

Reservation of terminal function failed during switchover or restart of programblock.

14480 CONNECTION FAILED IN ACTIVATION OF TERMINAL FUNCTION

Connection failed during activation of terminal function.

14481 RELEASE OF CONNECTION FAILED IN DEACTIVATION OF TERMINAL FUNCTION

Release of connection failed during deactivation of terminal function.

14482 PIU NOT READY

Plug in unit is not ready e.g to receive code from piload

14483 MULTIPLE TONS ARE USED IN THE ANALYSIS TREE

There are multiple types of number used in the analysis tree.

14489 XML DOCUMENT WAS READ TO END

XML document was read to end

14490 GIVEN BUFFER SIZE WAS ILLEGAL

Given buffer size was illegal. Buffer size must be over 0.

14492 CID VALUE DOES NOT EXIST

The given CID value was not found under the given AAL2 type VCLtp.

14493 UTOPIA EXTENDER LIBRARY NOT INITIALIZED

Abstraction library for Utopia Exntender hardware blocks has not been initialized (with the library initialization function).

14494 CID VALUE IS ALREADY IN USE

The given CID value is already part of AAL2 cross-connection

14495 PCM BELONGS TO ANOTHER COMPUTER

The PCM is controlled by another computer unit.

14496 LIBRARY CALL WITH INVALID PARAMETER

Utopia Exnterder library function was called with an invalid parameter (out of range, null etc.).

14497 INVALID OPERATION ON THIS HARDWARE

Current hardware environment does not support this Utopia Extender library operation (wrong plug-in unit).

14498 NO FREE CID VALUE EXISTS

No free CID values under the given AAL2 type VCLtp

14499 CREATION OF AAL2 CROSS-CONNECTION FAILED

Creation of AAL2 type cross-connection has failed during the creation sequence

14500 RELOADING OF A2SP UNITS HAS FAILED

Page 326: DX Error Messages

326 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Reloading of A2SP units to dynamic ATM routing structures has failed

14501 THE DEFINED AAL2 CC DOES NOT EXIST

The defined AAL2 cross-connection does not exist

14502 UTOPIA EXTENDER PORT WAS NOT FOUND

Utopia Extender port with the specified Utopia address was not found.

14503 DESTINATION DXT IS THIS DXT

The destination DXT cannot be the same DXT where the command is given.

14504 SUBSCRIPTION ALREADY EXISTS

Subscription already exists in subscription list

14505 SUGGESTED RESTART TYPE IS NOT ACCEPTED

Wrong restart type parameter (suggested restart type is not accepted)

14506 TIME-OUT IN RESTART PHASE 0

Duration of pre boot phase has exceeded its predefined time.

14507 TIME-OUT IN RESTART PHASE 1

Duration of restart phase 1 (code loading phase) has exceeded its pre-defined time.

14508 TIME-OUT IN RESTART PHASE 2

Duration of restart phase 2 (file loading phase) has exceeded its pre-defined time.

14509 TIME-OUT IN RESTART PHASE 3

Duration of restart phase 3 (application software starting phase) has exceeded its predefined time.

14510 NODE REFERENCE IN TRIE DIRECTORY IS INVALID

A pointer in quad node refers to non-existent record of trie file.

14511 ANNOUNCEMENT SENDING WAS UNSUCCESSFUL

The distributed part of Recovery Event Announcing Service was unable to send any announcements.

14513 BD-CHANNEL SET ALREADY EXISTS

The given Bd-channel set already exists.

14514 BD-CHANNEL SET DOES NOT EXIST

The given Bd-channel set does not exist.

14515 INVALID EXTENDED CELL RADIUS IN SITE TYPE MODIFICATION

In site type modification from Nokia 2nd generation to Nokia Talk-family the maximum extended cell radius allowed is 35 km.

14516 NASEVA PENDING TABLE IS FULL

Name server pending queue is full.

14517 BACKUP CHANNEL SET DOES NOT EXIST

Backup channel set does not exist.

14518 BACKUP CHANNEL SET IS ALREADY IN USE

Page 327: DX Error Messages

DN987378Issue 24-0

327

General Error Messages of System DX error messages

Id:0900d8058077e097

The given backup channel set is already in use.

14519 BACKUP CHANNEL SET UNIT TYPE IS INCORRECT

The unit type of given backup channel set is incorrect.

14520 NO FREE RECORDS IN BDDCON FILE

No free records in BDDCON file.

14521 P-CHANNEL ALREADY EXISTS

The given P-channel already exists.

14522 PTFILE FILE IS FULL

PTFILE file is full.

14523 P-CHANNEL DOES NOT EXIST

The given P-channel does not exist.

14525 OPTION MS CAPABILITY INDICATION IS NOT IN USE IN BSC

Option MS Capability Indication is not in use in the BSC.

14526 OPTION TRACE WINDOW FOR DROPPED CALLS IS NOT IN USE IN BSC

Option Trace Window for Dropped Calls is not in use in the BSC.

14527 SUBSCRIPTION NOT FOUND

Subscription not found from subscriber list.

14528 XML DOCUMENT BINARY CONVERSION FAILED

An error has occurred in converting ascii data from XML document into binary format.

14529 TDSC DISPATCHER STATION CONTROLLER IS NOT IN WORKING STATE

State of Tetra TDSC dispatcher station controller is not WO-EX. It is SE-ON or SE-NH or TE or BL.

14530 LEG CREATION FAILED

Failure in leg creation.

14552 LEG ALREADY EXISTS

Leg has already created.

14554 LEG RELEASE FAILED

Leg release failed.

14556 LEG DOES NOT EXIST

Leg does not exist.

14557 LEG CONNECT FAILED

Leg connection failed.

14558 LEG ALREADY CONNECTED

Leg is already connected.

14559 LEG DISCONNECT FAILED

Leg disconnection failed.

14560 LEG REFRESH FAILED

Page 328: DX Error Messages

328 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Leg refresh failed.

14561 LEG MODIFY FAILED

Leg modification failed.

14565 LEG MODIFY NOT RESTORED

Leg modification not restored.

14566 NO RIGHTS TO SERVICE TERMINAL SESSION

User has no rights to execute DDS command, therefore he has no rights to service terminal session.

14567 GIVEN NUMERICAL USER ID IS TOO SMALL

Enalib is unable to create user ID, because numerical user ID is too small.

14568 GIVEN NUMERICAL USER ID IS TOO BIG

Enalib is unable to create user ID, because numerical user ID is too big.

14569 B SERIES HWILIB ROUTINE

B series routine of HWILIB, that cannot be used in A series.

14570 PLUG-IN UNIT PORT ALREADY EXISTS

The port of plug-in unit already exists in equipment database and thus it cannot be created again.

14571 IMA GROUP DOES NOT EXIST

The given identifier is not assigned to any existing IMA Group.

14572 IMA GROUP ID ALREADY EXISTS

The given identifier is already assigned to another IMA Group. Repeat the command with a suitable value or let the system select a free one.

14573 ATM INTERFACE EXISTS

The operation could not be performed because there is an ATM inter-face related to the specified IMA Group.

14574 EXCHANGE TERMINAL ALREADY IN USE

At least one of the specified Exchange Terminals is already related to an IMA group or to an ATM interface. Check the existing Exchange Ter-minals and repeat the command with suitable values or release the Exchange Terminal if desired.

14575 THE EXCHANGE TERMINAL IS NOT IN THE IMA GROUP

The Exchange Terminal is not related to the IMA Group. Check the existing Exchange Terminals of the IMA Group and repeat the command with suitable values if desired.

14576 THE EXCHANGE TERMINAL IS THE TIMING REFERENCE LINK

The operation could not be performed because the Exchange Terminal is defined to be the Timing Reference Link of the IMA group. The exis-tence of the Timing Reference Link is essential for each IMA group. Check the existing Exchange Terminals of the IMA Group and repeat the command with suitable values if desired.

14577 IMA GROUP DATA INCONSISTENT IN THE SYSTEM

Page 329: DX Error Messages

DN987378Issue 24-0

329

General Error Messages of System DX error messages

Id:0900d8058077e097

An error occurred during the command execution. Corrective actions could not restore the consistency of the databases.

14578 ENDPOINT GROUP DOES NOT EXIST

The given identifier is not assigned to any endpoint group under the specified route.

14579 ENDPOINT GROUP ID ALREADY EXISTS

The given identifier is already assigned to another endpoint group under the specified route. Repeat the command with a suitable value or let the system select a free one.

14580 ENDPOINT GROUP WITH DEFINED SERVICE CATEGORIES ALREADY EXISTS

An endpoint group with the service categories defined already exists under the specified route. Use the existing endpoint group if suitable or repeat the command with different values.

14581 ENDPOINT GROUP DATA INCONSISTENT IN THE SYSTEM

An error occurred during the command execution. Corrective actions could not restore the consistency of the databases.

14582 THE ROUTE IS NOT AN EXTERNAL ATM ROUTE

The specified route is not suitable for the use of ATM channel selection. Check the parameters of the routes and repeat the command with a suitable route.

14583 AAL2 PATH DOES NOT EXIST

The given identifier is not assigned to any endpoint under the specified route.

14584 AAL2 PATH ID ALREADY EXISTS

The given identifier is already assigned to another endpoint under the specified route. Repeat the command with a suitable value.

14585 ENDPOINT EXISTS

The operation could not be performed because there are endpoint(s) under the specified endpoint group. If desired, delete the endpoints and repeat the command.

14586 ENDPOINT DATA INCONSISTENT IN THE SYSTEM

An error occurred during the command execution. Corrective actions could not restore the consistency of the databases.

14587 ENDPOINT GROUP WITH DEFINED SERVICE CATEGORIES DOES NOT EXIST

There is no endpoint group with the defined service categories under the specified route. Create a new endpoint group with suitable parame-ters if desired and repeat the command.

14588 ENDPOINT BLOCKING SITUATION IS ONLY PARTLY UPDATED

The blocking situation of the endpoint is only partly updated to the system. Some part of the system rejected the service request and the use of the specified endpoint might be prevented. This failure does not affects to the other endpoints or to the other parts of the

Page 330: DX Error Messages

330 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

system and the new data is also updated to the failed part in request or after restart.

14589 VPLTP USAGES DO NOT ALLOW THE CREATION OF PERMANENT VCLTPS

None of the usages defined for the VPLtp allows the creation of a per-manent VCLtp under this VPLtp. Compare the usages of the VPLtp with the usage you need the VCLtp and give the command again using a VPLtp with the usage you intend or redefine the usages of the VPLtp.

14590 VPLTP USAGES DO NOT ALLOW THE CREATION OF TEMPORARY VCLTPS

None of the usages defined for the VPLtp allows the creation of a tem-porary VCLtp under the VPLtp. Compare the usages of the VPLtp with the usage you need the VCLtp and give the command again using a VPLtp with the usage you intend or redefine the usages of the VPLtp.

14591 THE USAGE IS NOT ALLOWED FOR VPLTP

The specified usage can not be defined for VPLtps with service level VP. Check the behaviour of the usage.

14592 USAGE IS NOT ALLOWED FOR PERMANENT TERMINATION POINTS

The specified usage can not be defined for permanent termination points. Check the behaviour of the usage.

14593 THE USAGE IS NOT ALLOWED FOR TEMPORARY TERMINATION POINTS

The specified usage can not be defined for temporary termination points. Check the behaviour of the usage.

14594 THE USAGE IS NOT DEFINED FOR THIS VPLTP

The specified usage is not defined in the set of usages of this VPLtp. Check the usages defined for the VPLtp and redefine the set if desired.

14595 ONE OF THE USAGES REQUESTS NON-SHARED USE OF THE WHOLE VPLTP

The set of usages defined for the VPLtp is not allowed. At least one of the usages request non-shared use of the whole VPLtp so it can not be in a set with others. Check the behaviours of specified usages and redefine the set of usages.

14596 THE USAGE OF THE TERMINATION POINT DOES NOT ALLOW MODIFICATIONS

The specified termination point is in use and the usage does not allow a modification. Check the behaviour of the usage and free the termina-tion point if desired.

14597 THE USAGE OF THE TERMINATION POINT DOES NOT ALLOW SHUTTING DOWN

The specified termination point is in use and the usage does not allow shutting down. Check the behaviour of the usage.

14598 THE USAGE OF THE TERMINATION POINT DOES NOT ALLOW LOCKING

Page 331: DX Error Messages

DN987378Issue 24-0

331

General Error Messages of System DX error messages

Id:0900d8058077e097

The specified termination point is in use and the usage does not allow locking. Check the behaviour of the usage and free the termination point if desired.

14599 THE TERMINATION POINT IS IN USE

The specified termination point is in use and the operation can not be performed. If desired, free the termination point and repeat the command.

14600 NO ISDN PCMS FOUND FOR THE CONN.GROUP

No ISDN PCMs related to this connection group are found from the database.

14601 ILLEGAL RANGE

The number range which was attempted to insert into the DB was illegal.

14602 OVERLAPPING RANGE

The attempted range is overlapping with some existing range.

14603 RANGE IS NOT FOUND IN DB

The range is not found in the database.

14604 NUMBER IS NOT FOUND IN DB

The searched number is not found in the database.

14605 NUMBER ALREADY EXISTS

The number to be inserted already exists.

14606 ROUTING INFO IS NOT FOUND

The routing info for some number or range is not found.

14608 THE CONNECTION DOES NOT EXIST

The action cannot be performed because the connection needed for it does not exist.

14611 AAL2 SIGNALLING SERVICE UNAVAILABLE

Requested service cannot be activated due to the lack of resources. The service provider is not ready to perform the requested service. Check the system configuration and/or try again later.

14612 USAGE NOT AVAILABLE

Usage not available in the current software packet.

14613 THE NEW SET OF USAGES LACKS AN ALREADY ASSIGNED USAGES

There is at least one VCLtp assigned with one of the usages not defined in the new set of usages. Compare the new and existing set of usages and redefine the new set or free the reserved VCLtp if desired.

14614 ONE OF THE USAGES IN NOT FOR SERVICE LEVEL VC

At least one of the usages in the set can not be assigned to any VCLtp.Check the behaviours of the defined usages and redefine the set.

Page 332: DX Error Messages

332 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14615 FUNCTIONAL UNIT IS IN RESTART AND RESTART PROCEEDS NORMALLY.

Functional unit is restarting and restart proceeeds normally.

14616 GIVEN TCN IS CONNECTED TO ANALYSIS

Given time control number is connected to analysis

14617 GIVEN TCN ALREADY EXISTS

Given time control number already exists.

14618 PENDING REQUEST ADDED SUCCEFULLY TO PENDING TABLE.

Pending request added succefull to pending table.

14619 DATABASE HAS NO REMOTE COPY

The user has tried to handle database remote copy, but the database has no remote copy.

14620 TIME-OUT VALUE EXCEEDED FOR AAL TYPE 2 BLOCK OR UNBLOCK OPERATION

The peer signalling entity at the remote AAL type 2 Network Element didnot confirm the requested blocking or unblocking operation. Try again with checked parameters to be sure that operation is successfully completed.

14621 TIME-OUT VALUE EXCEEDED FOR AAL TYPE 2 RESET

The peer signalling entity at the remote AAL type 2 Network Element didnot confirmed the requested AAL type 2 reset operation. See the related alarm information for further actions.

14622 COMMAND CAN NOT BE APPLIED ON THIS DATABASE

Command cannot be applied on this database

14623 LOGICAL TERMINAL NUMBER CONFLICT IN FILES

The same logical terminal number is reserved for more than one channel in files.

14624 VCC WAS RESERVED, ALTHOUGH IT WAS ALREADY RESERVED TO SAME FAMILY

The VCC specified in this message was reserved, although it was reserved to another process which belongs to my process family.

14625 VCC WAS RE-RESERVED

The VCC specified in this message was reserved, although it was already reserved to me. In other words, the VCC is re-reserved to me.

14626 VCC WAS RELEASED, ALTHOUGH IT WAS RESERVED BY OTHER PROCESS OF SAME FAMILY

The VCC specified in this message was released, although it was reserved to another process which belongs to my process family.

14627 AN UNKNOWN ERROR HAPPENED WHILE RELEASING

The VCC specified in this message was not released, because an unknown error happened while releasing it.

14628 REMOTE COPY INFORMATION NOT AVAILABLE

Page 333: DX Error Messages

DN987378Issue 24-0

333

General Error Messages of System DX error messages

Id:0900d8058077e097

Database remote copy information is not available.

14629 INVALID INTERNAL ATM ROUTE USE

Given invalid value where internal ATM route is used for.

14630 TOO MANY ROUTES TO SIGNALLING POINT

There is already the maximum number of routes connected to same sig-nalling point.

14632 SGSN IS NOT UPDATED, PCU UNIT COMMUNICATION FAILURE.

Operation was partly successful, SGSN did not receive the request. Radio network database is updated.

14633 ROUTE LINKED TO SUBDESTINATION

Route must not be deleted if it is linked to some subdestination.

14634 ROUTE HAS VPC/VCC ENDPOINT GROUPS LINKED TO IT

Route must not be deleted if it has VPC/VCC endpoint groups linked to it.

14635 PRE-DETERMINED CROSS-CONNECTION

Pre-determined connection cannot be modified or deleted

14636 INTERNAL INTERFACE ID DOES NOT EXIST

Internal interface id does not exist for functional unit.

14648 ILLEGAL STATE

The state change of unit is not allowed. New state is illegal.

14649 ILLEGAL STATUS

The status change is not allowed. The status is not settable or clearable by the user.

14650 NOT A HOT STANDBY UNIT

Controlled switchover is not possible. The spare unit is not a hot standby.

14651 UNIT IS NOT A STANDBY UNIT

Controlled switchover is not allowed. Unit is not a standby unit.

14652 CAUSES SYSTEM RESTART

Unit restart is not allowed. It causes restart of whole system.

14653 UNIT IS NOT RESTARTABLE

The restart of unit is not possible. Unit is not restartable.

14654 MAXIMUM AMOUNT OF TRX LINKS IN USE

Maximum number of TRX links per BCSU in use.

14655 INTERNAL INFO TABLE OF DD1MAN IS FULL

The table containing information about DD2MAN families is full.

14656 NO FREE FAMILY ID FOR DD2MAN FAMILY

There are no free family id:s in the pool of family id:s for dd2man fami-lies.

14657 DD1MAN WAITING FOR SPARE UNIT STATE TO CHANGE

Page 334: DX Error Messages

334 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

DD1MAN is waiting for the spare unit to get out of the SP-UP state in order to be able to start DD2MAN family.

14658 UNIT STATE MUST BE WO BECAUSE IT HAS FRAME RELAY RESOURCES TO SUPERVISE

The working state of the unit must be active (WO) because it has frame relay resources to supervise.

14660 FAILURE IN SECMO PLUG-IN UNIT

A service has failed due to an error in the SECMO plug-in unit.

14661 LOCKING OF OBJECT ALLOWED ONLY WITH FORCED LOCK.

The locking of object is allowed only when forced lock is used.

14662 DATABASE SYSTEM PROGRAM BLOCK DENIES SWITCHOVER

The database system program block denies switchover.

14665 INVALID PCU BCSU LOGICAL ADDRESS

Invalid logical address of the host BCSU of PCU.

14666 INVALID PCU INDEX

Invalid PCU index.

14687 NS-VC CONNECTION IS UNAVAILABLE

The Bearer channel or the DLCI is blocked in Gb interface. The system activates the connection when the Bearer and DLCI are available again.

14694 VP/VC SELECTION COULD NOT BE UPDATED

The request was successful except for the update to VP/VC selection. If the modified object is irrelevant for VP/VC selection, this error can be ignored. If the object or objects thereunder are subject to VP/VC selec-tion, the system will still work but the specific endpoints are never used.

14695 FORBIDDEN: NOT IN HOME LOCATION

This error code appears if a request to modify some Packet Data-related object reaches a location that is not the home DXT.

14696 RAILIB CALL IS NOT ALLOWED IN UNIT

An attempt was made to call the RAILIB library in a unit where it is not allowed.

14697 WCEL OBJECT STATE CHANGE IS REJECTED DURING DATABASE COPY

An attempt was made to change the sate of the WCEL object during database copying when it is not allowed.

14701 INITIALIZATION NOT READY

Initialization concerning the given task in a functional unit is not yet ready

14702 MCC OR MNC IS NOT CONFIGURED.

MCC (Mobile Country Code) or MNC (Mobile Network Code) is not con-figured to the system.

14703 HMS OPERATION INTERRUPTED

The requested HMS operation was interrupted.

Page 335: DX Error Messages

DN987378Issue 24-0

335

General Error Messages of System DX error messages

Id:0900d8058077e097

14704 INVALID HMS MESSAGE LENGTH

The HMS message length is invalid.

14705 NO FREE TIC NUMBERS

No free tic numbers in the subscriber database to be reserved.

14706 ILLEGAL TIC NUMBER

The operator is trying to delete a non-existing tic number from the sub-scriber database.

14707 VCC RESERVATION FAILURE

Virtual channel connection could not be reserved by AAPSEB.

14708 WRONG VCC RESERVATION ATTRIBUTE

Virtual channel connection (VCC) could not be reserved because one of VCC attributes is illegal

14710 DATABASE REMOTE COPY INITIALIZATION FAILED

Database remote copy initialization failed.

14711 NO MORE DATABASE REMOTE COPY CONNECTIONS

No more database remote copy connections.

14712 DATABASE REMOTE COPY SERVER NOT INITIALIZED

Database remote copy server is not initialized.

14713 DATABASE REMOTE COPY SERVER DOES NOT ANSWER

Database remote copy server does not answer.

14714 DATABASE REMOTE COPY LOADING FAILED

Database remote copy loading failed.

14716 RNC NOT FOUND

The Radio Network Controller (RNC) object cannot be found in radio network database.

14717 WBTS NOT FOUND

The Base Station (WBTS) object can not be found in radio network database.

14718 WCEL NOT FOUND

The cell (WCEL) object cannot be found in radio network database.

14719 COCO NOT FOUND

The Connection Configuration (COCO) object cannot be found in radio network database.

14727 HMALAR IS BUSY

HMALAR is busy.

14728 RNC ALREADY CREATED

The Radio Network Controller (RNC) object is already created in radio network database.

14729 DATABASE REMOTE COPY LOADING DONE SUCCESSFULLY

Database remote copy loading was done successfully.

Page 336: DX Error Messages

336 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14730 WBTS ALREADY CREATED

The Base Station (WBTS) object is already created in radio network database.

14731 WCEL ALREADY CREATED

The Cell (WCEL) object is already created in radio network database.

14732 COCO ALREADY CREATED

The Connection Configuration (COCO) object is already created in radio network database.

14733 RACH NOT FOUND

The Random Access Channel (RACH) object cannot be found in radio network database.

14734 FACH NOT FOUND

The Forward Access Channel (FACH) object can not be found in radio network database.

14735 MAXIMUM OF WCELS UNDER WBTS

There is no room for a new cell (WCEL) under this Base Station (WBTS).

14736 DATABASE REMOTE COPY TIMER IS NOT CORRECT

Database remote copy timer is not correct.

14737 ADJS NOT FOUND

The Intra Frequency Adjacency (ADJS) object cannot be found in radio network database.

14738 ADJI NOT FOUND

The Inter Frequency Adjacency (ADJI) object cannot be found in radio network database.

14739 ADJG NOT FOUND

The GSM Adjacency (ADJG) object cannot be found in radio network database.

14740 FMCS NOT FOUND

The Intra Frequency Measurement Control (FMCS) object cannot be found in radio network database.

14741 FMCI NOT FOUND

The Inter Frequency Measurement Control (FMCI) object cannot be found in radio network database.

14742 FMCG NOT FOUND

The GSM Frequency Measurement Control (FMCG) object cannot be found in radio network database.

14743 HOPS NOT FOUND

The Intra Frequency Handover Path (HOPS) object cannot be found in radio network database.

14744 HOPI NOT FOUND

Page 337: DX Error Messages

DN987378Issue 24-0

337

General Error Messages of System DX error messages

Id:0900d8058077e097

The Inter Frequency Handover Path (HOPI) object cannot be found in radio network database.

14745 HOPG NOT FOUND

The GSM Handover Path (HOPG) object cannot be found in radio network database.

14746 FMCS ALREADY CREATED

An Intra Freaquency Measurement Control (FMCS) object with the given identity is already created in radio network database.

14747 FMCI ALREADY CREATED

An Inter Frequency Measurement Control (FMCI) object with the given identity is already created in radio network database.

14748 FMCG ALREADY CREATED

A GSM Measurement Control (FMCG) object with the given identity is already created in radio network database.

14749 HOPS ALREADY CREATED

An Intra Frequency Handover Path (HOPS) object with the given identity is already created in radio network database.

14750 HOPI ALREADY CREATED

An Inter Frequency Handover Path (HOPI) object with the given identity is already created in radio network database.

14751 HOPG ALREADY CREATED

A GSM Handover Path (HOPG) object with the given identity is already created in radio network database.

14752 ADJS COLLECTION FULL

There is no room for a new Intra Frequency Adjacency (ADJS) object in radio network database.

14753 ADJI COLLECTION FULL

There is no room for a new Inter Frequency Adjacency (ADJI) object in radio network database.

14754 ADJG COLLECTION FULL

There is no room for a new GSM Adjacency (ADJG) object in radio network database.

14755 FMCS COLLECTION FULL

There is no room for a new Intra Frequency Measurement Control (FMCS) object in radio network database.

14756 FMCI COLLECTION FULL

There is no room for a new Inter Frequency Measurement Control (FMCI) object in radio network database.

14757 FMCG COLLECTION FULL

There is no room for a new GSM Frequency Measurement Control (FMCG) object in radio network database.

14758 HOPS COLLECTION FULL

Page 338: DX Error Messages

338 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

There is no room for a new Intra Frequency Handover Path (HOPS) object in radio network database.

14759 HOPI COLLECTION FULL

There is no room for a new Inter Frequency Handover Path (HOPI) object in radio network database.

14760 HOPG COLLECTION FULL

There is no room for a new GSM Handover Path (HOPG) object in radio network database.

14761 WCEL COLLECTION FULL

There is no room for a new Cell (WCEL) object in radio network data-base.

14762 COCO COLLECTION FULL

There is no room for a new Connection Configuration (COCO) object in radio network database.

14763 RACH COLLECTION FULL

There is no room for a new Random Access Channel (RACH) object in radio network database.

14764 FACH COLLECTION FULL

There is no room for a new Forward Access Channel (FACH) object in radio network database.

14765 MAXIMUM OF ADJSS FOR WCEL

The maximum of Intra Frequency Adjacency (ADJS) object relations for the Cell (WCEL) object is reached.

14766 MAXIMUM OF ADJIS FOR WCEL

The maximum of Inter Frequency Adjacency (ADJI) object relations for the Cell (WCEL) object is reached.

14767 MAXIMUM OF ADJGS FOR WCEL

The maximum of GSM Adjacency (ADJG) object relations for the Cell (WCEL) object is reached.

14768 COCO AND WBTS ALREADY RELATED

The relation between the Connection Configuration (COCO) object and Base Station (WBTS) object already exists.

14769 NO RELATION BETWEEN COCO AND WBTS

No relation between the Connection Configuration (COCO) object and the Base Station (WBTS) object exists.

14770 UNKNOWN PID OWNER

The value of the pid owner parameter is unknown to radio network data-base.

14771 NO COCO DEFINED FOR WBTS

The identity of the used Connection Configuration (COCO) object is not defined in Base Station (WBTS) parameters.

14772 ILLEGAL TARGET SUBDATABASE

Page 339: DX Error Messages

DN987378Issue 24-0

339

General Error Messages of System DX error messages

Id:0900d8058077e097

The used transaction or fastread is directed to an unknown or illegal subdatabase of RAQUEL.

14773 CONNECTION IS NOT IN LOCKED STATE

The specified operation requires the connection to be in locked admin-istrative state. In case of a ptm connection the operations related only to one branch requires the specified branch or the whole connection to be in locked administrative state.

14779 THERE ARE NO FREE RESOURCES FOR REQUESTED SERVICE

Requested service cannot be performed because there are no free resources.

14780 ERROR IN READING OR WRITING A DISK FILE

A file in a hard disk is corrupted or the file system services failed somehow. Check the system logs to find the possible cause.

14783 HOT DATA IP CONNECTION FAILED

HBSAVE can not get connection to post-processing system.

14784 HOT DATA IP CONNECTION LOST

HBSAVE lost connection to post-processing system.

14786 BTS SOFTWARE DOES NOT SUPPORT GPRS

GPRS cannot be enabled in this BTS because the BTS software build has no GPRS capability.

14792 CALL ROUTE FOR THIS DXT STILL EXISTS IN ROUTING TABLE

The DXT definition cannot be deleted, because the call route still exists in the routing table.

14801 DXT ID IS NOT IDENTICAL WITH THE PREDEFINED C-NUMBER IN APPARA FILE

The given exchange identifier differs from the C-number in the general parameter module (APPARA).

14802 INVALID FILE SYSTEM

The requested file system is not supported by the device in question.

14804 GIVEN LOCATION AREA IDENTIFICATION NOT WITHIN LIMITS

Given location area identification not within limits.

14812 SPECIFIED ROUTER IS NOT CONFIGURED.

The router cannot be found in the file /etc/iprou.dat. If you need this router, you must first add it to that file either with the WWW user inter-face or with the MML command QKS.

14813 SPECIFIED AREA IS NOT CONFIGURED.

The area cannot be found in the file /etc/iprou.dat. If you need this area, you must first add it to that file either with the WWW user interface or with the MML command QKE.

14814 SPECIFIED STUB HOST IS NOT CONFIGURED.

The stub host cannot be found in the file /etc/iprou.dat. If you need this stub host, you must first add it to that file either with the WWW user interface or with the MML command QKJ.

Page 340: DX Error Messages

340 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14815 SPECIFIED NETWORK PREFIX IS NOT CONFIGURED.

The network prefix cannot be found in the file /etc/iprou.dat. If you need this network prefix, you must first add it to that file either with the WWW user interface or with the MML command QKH.

14816 SPECIFIED VIRTUAL LINK IS NOT CONFIGURED.

The virtual link cannot be found in the file /etc/iprou.dat. If you need this virtual link, you must first add it to that file either with the WWW user interface or with the MML command QKV.

14817 SPECIFIED NETWORK INTERFACE IS NOT CONFIGURED

The network interface cannot be found in the file /etc/iprou.dat. If you need this network interface, you must first add it to that file either with the WWW user interface or with the MML command QKF.

14818 ACCESS TO BACKBONE AREA IS REQUIRED IF MORE THAN ONE AREA IS CONFIGURED

If two or more areas are configured, one of them must be the backbone area or there must be a virtual link from one of the areas to the backbone area.

14819 STUBBY AREA CANNOT BE A TRANSIT AREA.

The area cannot be a stubby area and a transit area to the backbone area at the same time.

14820 THE NETWORK PREFIX IS NOT CORRECT.

The mask length shows the bit after which all bits have to be zeroes.

14824 INVALID TUPLE FOR A STORAGE STRUCTURE

The given tuple cannot be stored into the storage structure. Typically this means that the home area of the structure is too small.

14825 NETWORK PREFIX IS ALREADY IN USE IN ANOTHER AREA

The network prefix is already in use some other area. Use different address.

14826 HUNTING METHOD CHANGE IS NOT ALLOWED

It is not allowed to change the hunting method of the circuit croup.

14827 COUNTER ALREADY EXISTS

Counter requested from AAPSEB already exists

14828 COUNTER IS ALREADY REMOVED

Counter requested from AAPSEB is already removed

14829 COUNTER NOT EXISTS

Counter requested from AAPSEB does not exist

14830 BOTH THRESHOLDS ARE REMOVED

Both thresholds whose removing is requested from AAPSEB are removed

14831 ONE THRESHOLD IS REMOVED

One threshold of the thresholds of this counter is removed. The another threshold still exists.

Page 341: DX Error Messages

DN987378Issue 24-0

341

General Error Messages of System DX error messages

Id:0900d8058077e097

14832 THRESHOLD NOT EXISTS

Threshold requested from AAPSEB does not exist.

14833 NO VCC ACTIVE

Counter request for VCC which in not active

14834 COUNTER OPERATION FAILURE

Operation reqested for counter failed.

14835 COUNTER RESOURCES ARE FULLY BOOKED

Counter requested cannot be set because resources are fully booked.

14836 HUNTING OF A PHYSICAL RESOURCE FOR A LEG HAS FAILED

The hunting of a resource from a given route has failed.

14837 THE LEG IS NOT CONNECTED

The leg is not connected, meaning it is already disconnected.

14838 RESTRICTED BECAUSE THE SUBSCRIBER IS TELEMETRIC

Only IMSI, MSISDN, activation status, SAM, VLR address and/or MSC address can be modified for a telemetric subscriber.

14840 VCCE DOES NOT EXIST

VCC endpoint does not exist.

14841 UX ASIC ALREADY INITIALIZED

UX ASIC already intialized.

14842 MAXIMUM NUMBER OF AAL2 CROSS-CONNECTIONS HAS BEEN REACHED

The maximum number of AAL2 cross-connections has been reached for a certain N_CID VCC endpoint. The new AAL2 cross-connection cannot be accepted.

14843 TERMINATION POINT HAS AN ENDPOINT RELATED TO IT

The operation could not be performed because there is an endpoint related to the specified Termination Point. This error is caused by the missfunctioning of a program block in the system. Check the computer log file for detailed information and contact the local Nokia Customer Service Center.

14844 THE ENDPOINT GROUP IDENTIFIER IS OUT OF ITS RANGE

The specified identifier for the endpoint group is not within the range allowed for it. Check the range of the endpoint group identifier in the Command Manual and try again. This error might also be caused by the missfunctioning of a program block in the system. Check the computer log file for detailed information and contact the local Nokia Customer Service Center.

14845 THERE IS NO FREE ENDPOINT GROUP IDENTIFIERS UNDER THE SPECIFIED ROUTE

There is no free identifier for the endpoint group under the specified route.This error is caused by the missfunctioning of a program block in the system. Check the computer log file for detailed information and contact the local Nokia Customer Service Center.

Page 342: DX Error Messages

342 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14846 DURING INITIALISATION OF AAL2 CAC STATIC TABLES ONE TABLE HAS BECOME TOO LARGE

During initialisation of AAL2 CAC static tables one table has become too large.

14847 DSP APPLICATION OR HARDWARE FAILURE

A DSP application has encountered an error which may be a result of a hardwdare fault.

14848 AIHLIB IS NOT INITIALIZED

This error is returned by AIHLIB routines when they are called before library is initialized by calling aap_init_sar_r routine.

14849 INVALID PARAMETER PEER ID

This error is returned by AIHLIB routines if incorrect or not initialized peer id is passed to the routine.

14850 REFERENCED PEER IS NOT ACTIVE

This error is returned by AIHLIB functions when the operation on non active peer is requested (and the peer is supposed to be active)

14851 NO DATA RECEIVED

This error is returned by aap_receive_data_r routine when they werent any data received but the routine was called anyway. (AIHLIB)

14852 AIHLIB COULD NOT ALLOCATE BUFFER

Returned by AIHLIB routines when the alloc_buffer_r function failed to allocate data buffer.

14853 INSUFFICIENT AIHLIB TX RESOURCES

Set by AIHLIB TX functions when there are not enough resources to handle TX channels.

14854 INSUFFICIENT MAIN MEMORY FOR AIHLIB

Returned by AIHLIB initialization routines if there is not enough memory allocated for AHILIB internal structures. Usually happens when big amount of channels is requested.

14855 INSUFFICIENT AIHLIB SAR SRAM MEMORY

Returned by AIHLIB routines if SAR SRAM is not big enough to create AIHLIB internal and SAR structures. Usually happens when big amount of channels is requested.

14856 REQUESTED AIHLIB CHANNEL IS NOT ACTIVE

Returned by AIHLIB routines when the action is to be done on non active virtual channel (and the channel is supposed to be active). Usually happens when the channel was not initialized.

14857 INSUFFICIENT RESOURCES IN AIHLIB VCC POOL

returned by AIHLIB routines when there are not enough preallocated channels.

14858 INVALID AIHLIB VCC PARAMETER

Returned by AIHLIB routines when invalid or not initalized VCC is passed to them.

Page 343: DX Error Messages

DN987378Issue 24-0

343

General Error Messages of System DX error messages

Id:0900d8058077e097

14859 SERVICE CATEGORY NOT SUPPORTED BY AIHLIB

Returned by AIHLIB routines when channel with not supported service cathegory is requested.

14860 INSUFFICIENT AIHLIB PEER POOL

Returned by AIHLIB routines when there are not enough preallocated peers available.

14861 AIHLIB VCC IS NOT ACTIVE

Returned by AIHLIB routines when referenced VCC is active and it is supposed to by non active.

14862 REASSEMBLY OAM DISABLED IN AIHLIB

Returned by AIHLIB routines when RSM OAM is disabled and it should be enabled.

14863 AIHLIB SEG PRIORITY ERROR

Returned by AIHLIB when the channel with illegal priority is requested.

14864 NON-REDUNDANT ACTIVE MXU IS RESTARTED

An active MXU restarted when spare MXU cannot be taken in to use.

14865 SERVICE UNAVAILABLE - WARM-UP IN PROGRESS

Acknowledgement error code to service request, when service is temporarily unavailable, because of warm-up.

14866 NO CIRCUITS EXIST

None of the circuits to be deleted were found from circuit groups.

14867 ALL CIRCUITS EXIST

All circuits were already found from correct circuit groups.

14868 THE USAGE OF THE TERMINATION POINT IS NOT THE ONE SPECIFIED

The termination point is not in the specified usage and therefore the requested operation is not allowed. This error might be caused by the missfunctioning of a program block in the system. Check the computer log(s) for detailed information and contact the local Nokia Customer Service Center.

14869 THE OPERATION IS NOT IMPLEMENTED

The requested operation is not implemented yet. Check the computer log(s) for detailed information.

14870 NO RESPONSE FROM STATISTICAL PROGRAM BLOCK

An acknowledgement for the sent message was not received from the statistical program block (EXSPRO/MDUPRB/STPROC). The reason for the error may be that there is a momentary overload in the statistical program block.

14871 STATISTICAL DATA COLLECTION NOT STARTED

The statistical program block (EXSPRO/MDUPRB/STPROC) cannot start the requested data collection for the statistical measurement. The reason for the error may be that the MDFFIL file is corrupted and so the requested data collection is incorrect.

Page 344: DX Error Messages

344 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14872 STATISTICAL DATA COLLECTION NOT STOPPED

The statistical program block (EXSPRO/MDUPRB/STPROC) cannot stop the requested data collection.

14873 ERROR IN REQUESTED SERVICE FROM STATISTICAL FILE SERVICES PROGRAM BLOCK

The error code originates from the Statistical File Services Program Block upon detection of an invalid parameter in a service request.

14875 RESOURCE REMOVAL NOT FULLY PERFORMED

Resource removal was not fully performed.

14876 UNABLE TO ACTIVATE HOT DATA DISK BUFFERING

Activation of the hot data disk buffering failed.

14877 MASTER BTS OF SEG NOT FOUND IN RNW DATABASE

The segment has no master BTS.

14878 SEG NOT FOUND IN RNW DATABASE

The segment has not been created into the RNW database.

14879 ILLEGAL SEG ID

An attempt has been made to use illegal or incompatible SEG identifi-cation.

14880 THERE ARE TOO MANY BTSS IN ONE SEG

The maximum number of BTSs is already created to the segment.

14881 THERE ARE TOO MANY TRXS IN ONE SEG

The maximum number of transceivers allowed in the segment has been reached.

14882 MOVING OF BTS CONTAINING BCCH TRX NOT ALLOWED

BTS containing BCCH TRX can not be moved to an another segment.

14883 SEGMENT USAGE OPTION NOT IN USE IN BSC

Segment usage option is not in use in the BSC.

14884 SEG NAME ALREADY IN USE

A SEG name must be unique in the BSC.

14885 SEG NAME IS ILLEGAL

A SEG name may consist of allowed characters only.

14886 ILLEGAL VALUE OF MULTIBCFMASTER

Parameter multiBCFmaster has illegal value.

14887 MOVING OF MASTER BTS NOT ALLOWED

Master BTS can not be moved to another segment.

14888 NOT MASTER BTS

Some operation has been tried to do to a BTS which is not a master BTS.

14889 ILLEGAL BTS ID

An attempt has been made to use illegal or incompatible BTS identifica-tion.

Page 345: DX Error Messages

DN987378Issue 24-0

345

General Error Messages of System DX error messages

Id:0900d8058077e097

14890 MASTER BTS SHIFT IS ALLOWED ONLY BETWEEN BASE TRANS-CEIVER STATIONS OF SAME SEGMENT

Master BTS information can not be shifted to BTS in another segment.

14891 TOO MANY BASE TRANSCEIVER STATIONS IN SOURCE SEGMENT

There can be only one BTS (master BTS) in the segment when master BTS is tried to be moved to another segment.

14892 VIRTUAL FILE LOADING IS GOING ON

When the virtual file loading is going on, switchover and state change may not be done to the source unit.

14893 LOADING LOG BUFFERS DURING DATABASE WARM UP FAILED

The database warm up library could not load log buffers from working unit to the spare unit during database warm up. Database warm up failed.

14894 DYNAMIC ABIS POOL WAS NOT FOUND IN RNW DATABASE

The Dynamic Abis pool has not been created into the RNW database.

14895 NO MORE TRANSCEIVERS CAN BE ATTACHED IN SAME DYNAMIC ABIS POOL

The maximum number of transceivers allowed in the Dynamic Abis pool has been reached.

14896 GATEWAY DXT CANNOT BE REMOVED FROM A SUBNET

The DXT to be removed from a subnet cannot be the Gateway of the subnet

14897 PARAMETER TIME GROUP OF ADJACENT CELL DIFFERS FROM CORRESPONDING OWN CELL VALUE

The time group parameter value given to an adjacent cell to be created or modified differs from that of the own cell.

14898 TRANSMISSION EQUIPMENT IN BSS SYNCHRONIZATION USE

Transmission equipment deletion is not possible because it is used for BSS synchronization purposes. Remove it from BSS synchronization use and try again.

14899 RESERVATION IS PUT INTO QUEUE

Reservation of WBTS failed, but reservation is put into queue.

14900 RADIONETWORK DATABASE WAS RESERVED FOR SOME OTHER OPERATION

Requested operation cannot be performed because some other opera-tion (e.g. some plan operation) has reserved the whole radionetwork database.

14901 RESERVATION FAILED

Reservation of WBTS failed because it is already reserved.

14902 RESERVATION IS PUT INTO QUEUE.

Reservation of database failed but reservation is put into queue. New reservations for WBTS are not allowed.

Page 346: DX Error Messages

346 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14903 OPERATION REQUIRES THAT ALL WCELS UNDER THE WBTS MUST BE LOCKED

Requested operation failed because not all WCELs under the WBTS were locked.

14904 MAXIMUM NUMBER OF WBTSS EXCEEDED

WBTS creation failed because maximum number of WBTSs has already been created to the RNW database.

14905 MAXIMUM NUMBER OF WCELS EXCEEDED

WCEL creation failed because maximum number of WCELs has already been created to the RNW database.

14906 MAXIMUM NUMBER OF WCELS UNDER WBTS EXCEEDED

WCEL creation failed because maximum number of WCELs has already been created under the WBTS.

14907 SOME OTHER OPERATION IS GOING ON TO SAME OBJECT

Operation could not be performed because the object was undergoing some other operation at the same time.

14908 NO ANSWER RECEIVED FROM PROCESS HA3 IN TIME

Timer for waiting an answer message from process HA3 has expired, and no answer has been received.

14909 NO ANSWER RECEIVED FROM PROCESS VEXELI IN TIME

Timer for waiting an answer from VEXELI has expired and no answer has been received.

14910 SERVICE PROVIDER PID IS NOT FOUND

The PID of the program block offering the needed service could not be resolved.

14911 NO ANSWER RECEIVED FROM BRM IN TIME

Timer for waiting an answer from BRM has expired, and no answer has been received.

14912 COCO OBJECT IS BEING USED BY SOME WBTS

CoCo can not be connected to the requested WBTS because it is already being used by some WBTS.

14913 TIMER FOR WAITING ANSWER FROM OBHERO EXPIRED

Timer set for waiting an answer from OBHERO has expired and no answer has been received.

14914 POSITION BASED SERVICES OPTION IS NOT IN USE IN BSC

The Position Based Services option is not in use in BSC. The purpose of the Position Based Service in BSC feature is to locate subscriber and/or validate mobile equipment or to send the assistance data to the MS.

14915 SOME SUBTIMESLOTS ARE MISSING FROM REQUEST

All subtimeslots of physical timeslot were not given.

14916 SOME WCELS EXIST UNDER THE WBTS TO BE DELETED

Page 347: DX Error Messages

DN987378Issue 24-0

347

General Error Messages of System DX error messages

Id:0900d8058077e097

WBTS can not be deleted from database while there are WCELs under it.

14917 SIGNALLING LINK IN USE

Signalling link release is not allowed due the on-going user data con-nections. The protocol state inside the signalling link prohibits release. Try again release with an override parameter if you are absolutely sure that the signalling link can be released despite of the protocol state.

14918 MISMATCH BETWEEN COCO ID AND C-NBAP PARAMS IN WBTS AND COCO-OBJECT

The CoCo object (specified with CoCo id) in database has different C-NBAP parameters than those specified in WBTS, or the C-NBAP address specified in WBTS is not defined in CoCo as C-NBAP address.

14919 OPERATION REQUIRES WCEL OBJECT TO BE LOCKED

The requested operation can not be done because it requires the WCEL state to be locked (bl- by user).

14920 NO ANSWER RECEIVED FROM PROCESS REKOVE IN TIME

Timer for waiting a response from REKOVE has expired and no response has been received.

14921 NO ANSWER RECEIVED FROM PROCESS REZINI IN TIME

Timer set for waiting a response from rezini has expired and no response has been received.

14922 INVALID STATE ACTION VALUE

The value of state action parameter (in WCEL state change) is incor-rect.

14923 DURING EXECUTION OF THE AAL2 CAC ALGORITHM A CHECK OF AN ARITHMETIC FIELD HAS FAILED

During execution of the AAL2 CAC algorithm, a check of an arithmetic field has failed. This indicates for instance that a certain field is out of its bounds (e.g. calculation safety bounds).

14924 TIME FOR WAITING RESPONSE FROM RRCPRB IS UP

A timer set for waiting a response from rrc process has expired and no response has been received.

14925 WRONG COMPUTER UNIT ERROR

An attempt has been made to give the task to a wrong computer unit.

14926 INVALID MACS

The value of MACS (Message Authentication Code for Synchronisa-tion) was not the expected value.

14929 THE SPECIFIED INTERFACE DOES NOT EXIST

Interface switchover can not be executed because the target interface does not exist

14930 UNIT IS STARTING UP

Operation is not allowed because unit is restarting.

14931 UNIT IS UNDER PERIODICAL MONITORING

Page 348: DX Error Messages

348 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Switchover is not allowed because unit is under periodically monitoring.

14932 WBTS COLLECTION FULL

There is no room for a new Base Station (WBTS) object in radio network database.

14933 INTERNAL ERROR IN RNW DATABASE

An internal error has occured in radio network database.

14934 FMC STILL USED BY SOME WCEL

FMC can not be deleted, because it is still used by some WCEL.

14935 MULTI BCF OPTION IS NOT IN USE IN THE BSC

The option Multi BCF is not in use in the BSC.

14936 COMMON BCCH GSM 900 OPTION IS NOT IN USE IN THE BSC

The Common BCCH GSM 900 option is not in use in the BSC.

14937 COMMON BCCH GSM 1800 OPTION IS NOT IN USE IN THE BSC

The Common BCCH GSM 1800 option is not in use in the BSC.

14938 BTS SITE TYPE MODIFICATION NOT ALLOWED FOR BCF WITH SEG OF SEVERAL BTS

The modification of the BTS site type is not possible if the BCF in question contains segments of more than one BTS.

14939 SEG NOT ALLOWED FOR 2ND GENERATION SITE TYPE

The segment is not allowed for the Nokia 2nd generation site type.

14940 PRIMESITE CAN ONLY HAVE SEG WITH ONE BCF

The Nokia PrimeSite can only have segments with one BCF.

14941 ILLEGAL SEG CONFIGURATION

The segment configuration is illegal.

14942 THE FREQUENCY BAND IS INCORRECT FOR SEG

This frequency band is not allowed for segment with several different frequency bands.

14943 INSITE DOES NOT SUPPORT THE COMMON BCCH FEATURE

The Nokia InSite does not support the feature Common BCCH.

14944 SEG WITH ONE BTS CANNOT BE MOVED TO A NONEXISTING SEG

A segment with one BTS cannot be moved to a new segment.

14945 EGPRS CLASSIC DOES NOT SUPPORT THIS BTS SITE TYPE

The feature EGPRS Classic does not support this BTS site type.

14946 EGPRS COMPACT DOES NOT SUPPORT THIS BTS SITE TYPE

The feature EGPRS Compact does not support this BTS site type.

14947 BB HOPPING IS NOT SUPPORTED BY EGPRS COMPACT

The base band hopping is not supported by the feature EGPRS Compact.

14948 THE PARAMETER CANNOT BE MODIFIED

The parameter cannot be modified by user.

Page 349: DX Error Messages

DN987378Issue 24-0

349

General Error Messages of System DX error messages

Id:0900d8058077e097

14949 THE RADIO TIME SLOTS FROM 1 TO 7 HAVE TO BE TCHF

The radio time slots from 1 to 7 have to be of TCHF type.

14950 TSC (TRX) AND BCC (CELL) VALUES MUST BE EQUAL IN BB-HOPPING LAYER

The Training Sequence Codes of the TRXs and the BTS Colour Code of BB-hopping layer, which has BCCH or PBCCH TRX, must be equal.

14951 UPDATING THE CURRENT TIME FAILED BECAUSE O&M LINK BUSY

The current time cannot be updated for BTS because the O&M link is busy.

14952 RDOMAN HAS NOT RESPONDED TO SERVICE REQUEST

RDOMAN has not responded to service request.

14953 RDOMAN UNIT CPU LOAD TOO HIGH

RDOMAN has rejected service request because of a too high CPU load in its unit.

14954 RDOMAS FAILED TO CREATE HAND PROCESS

Service request can not be processed, because RDOMAS failed to reserve a hand process for it.

14955 RDOHAN FROZE WHILE RUNNING REQUEST

RDOHAN hand process froze while attempting to process the service request. RDOHAN was stopped.

14956 MSISDN NUMBER REFERS TO INTERNAL SUBSCRIBER

While creating a relation between FSSN and MSISDN, MSISDN was already in relation with an internal subscriber.

14957 DATA BUS TEST FAILS

Testing of the memory data bus fails.

14958 ADDRESS BUS TEST FAILS

Testing of the memory address bus fails.

14959 MEMORY DEVICE TEST FAILS

Testing of the memory device fails.

14960 COCO ID AND WBTS ID DO NOT MATCH

The CoCo ID and WBTS ID given in the service request are not related to each other in the system.

14961 CONTROL/USER PLANE DELETION FAILED

Control/User plane deletion was not completed successfully.

14962 CONTROL/USER PLANE CREATION FAILED

Control/User plane configuration was not completed successfully.

14963 GIVEN VCI VALUE IS ALREADY IN USE

The given VCI value is already used by some other instance.

14964 AAL2 SIGNALLING VCI IS USED BY AAL2 UPLINK

The AAL2 signalling link is used by AAL2 user plane link.

Page 350: DX Error Messages

350 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

14965 ATM MODIFICATION IS NOT ALLOWED IN THIS CASE

ATM modification is not allowed with this service for the connected CoCo object.

14966 O&M IP OVER ATM LINK ALREADY EXISTS

The DCN for O&M IP over ATM link already exists for the given ATM interface.

14967 NUMBER OF EGPRS COMPACT CONTROL BLOCKS IS UNDER 4

The total amount of control blocks (CPBCCH and CPCCCH) has to be at least 4 when EGPRS Compact is in use.

14968 ILLEGAL CPBCH LOCATION

Compact packet broadcast control channel (CPBCH) was in other timeslot than RTSL 0.

14969 GPRS ENABLED TRX IS NOT EDGE CAPABLE

HW of GPRS Enabled TRX is not EGPRS-compatible with a BTS which has EGPRS (Enhanced General Packet Radio Service) enabled.

14970 ERROR IN I2PLIB MODULE

The service request could not be processed, because operating the shared memory via I2PLIB function returned an error code.

14971 ERROR IN HEADER COMPRESSION MODULE

The service request could not be processed, because operating the header compression module returned an error code.

14972 ALLOCATING RESOURCES FOR HEADER COMPRESSION FAILED

Resources for the header compression algorithm could not be allo-cated. However, the request was otherwise served and the channel is ready to continue in operation using given parameters, but without support for the header compression.

14973 CONTROL CHANNEL TERMINATION MANAGEMENT SERVICE NOT AVAILABLE

The control channel termination management service cannot be found in the system.

14974 ATM LOGICAL RESOURCE MANAGEMENT SERVICE NOT AVAIL-ABLE

The ATM logical resource management service cannot be found in the system.

14975 SERVICE FOR CREATING OR DELETING THE DIGIT ANALYSIS NOT AVAILABLE

The service for creating or deleting the digit analysis cannot be found in the system.

14976 ATM ROUTE MANAGEMENT SERVICE NOT AVAILABLE

The ATM route management service cannot be found in the system.

14977 RESERVATION SERVICE FOR RNW OBJECTS NOT AVAILABLE

The reservation service for RNW objects cannot be found in the system.

Page 351: DX Error Messages

DN987378Issue 24-0

351

General Error Messages of System DX error messages

Id:0900d8058077e097

14978 RNC RADIO NETWORK CONFIGURATION MANAGEMENT SERVICES NOT AVAILABLE

The RNC Radio Network Configuration Management services cannot be found in the system.

14979 NO RESPONSE TO CONTROL CHANNEL TERMINATION MANAGE-MENT SERVICE REQUEST

There was no response to the control channel termination management service request.

14980 NO RESPONSE TO ATM LOGICAL RESOURCE MANAGEMENT SERVICE REQUEST

There was no response to ATM logical resource management service request.

14981 NO RESPONSE TO SERVICE REQUEST FOR CREATING OR DELETING THE DIGIT ANALYSIS

There was no response to service request for creating or deleting the digit analysis.

14982 NO RESPONSE TO ATM ROUTE MANAGEMENT SERVICE REQUEST

There was no response for ATM route management service request.

14983 NO RESPONSE TO REQUEST FOR THE RESERVATION SERVICE FOR RNW OBJECTS

There was no response to the request for the reservation service for RNW objects.

14984 NO RESPONSE TO REQUEST FOR RNC RADIO NETWORK CON-FIGURATION MANAGEMENT SERVICES

There was no response to the request for RNC Radio Network Config-uration Management services.

14985 DETECTION POINT ALREADY ACTIVE

Detection point is already set to active for the subscriber.

14986 DETECTION POINT ALREADY DEACTIVATED

The detection point is already set to passive for the subscriber.

14987 MESSAGE HAS BEEN SENT TO WRONG COMPUTER UNIT

The message has been received by a wrong computer unit.

14988 VLR ASSOCIATED WITH GIVEN LA FOUND IN DATABASE

The requested operation is not allowed because a VLR object associ-ated with given LA is found in database.

14989 CONTROL CHANNEL IS DOWN DUE TO MODIFY OPERATION

Control channel is down due to modify operation. The channel was tried to be modified and modification failed for new given parameters and after that also rollback to old parameters failed.

14990 COMMON BCCH E-GSM 900 OPTION IS NOT IN USE IN THE BSC

The Common BCCH E-GSM 900 option is not in use in the BSC.

14991 COPY CONTROL FILE MISSING

Page 352: DX Error Messages

352 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The copy control file is missing from source or destination directory.

14992 COPY CONTROL FILE IS CORRUPTED

The copy control file on removable media is physically or logically cor-rupted.

14993 NEITHER PBCCH NOR CPBCCH CHANNEL EXISTS IN THE CELL

The cell does not have a Packet Broadcast Control Channel.

14994 ALLOCATION IS REJECTED BECAUSE OF TOO STRICT DELAY REQUIREMENTS

Allocation is rejected because of too stirict delay requirements.

14995 AAL2 SIGNALLING LINK MANAGEMENT SERVICE NOT AVAILABLE

The AAL2 signalling link management service was not found in the system.

14996 NO RESPONSE TO AAL2 SIGNALLING LINK MANAGEMENT SERVICE REQUEST

There was no response to AAL2 signalling link management service request.

14997 ATTACHED INTERFACES INTERROGATION FAILED

The interrogation of the attached interfaces of given computer unit failed.

14998 MAXIMUM NUMBER OF IP ADDRESSES EXCEEDED

The number of the IP addresses exceeded the maximum allowed.

14999 NETWORK INTERFACE IS NOT DOWN

The administrative state of the TCP/IP network interface is not down.

15000 NOT READY FOR AROFIL FILE WARM UP

S3DROU program block has sent the first AROFIL warm-up request message to S3CMAN program block, but S3CMAN is not yet ready for warm-up.

15001 RAC PARAMETER OF ADJACENT CELL DIFFERS FROM CORRE-SPONDING OWN CELL VALUE

The value of routing area code of adjacent cell to be created or modified is different from the parameter value in the own cell.

15002 GPRS_MS_TXPWR_MAX PARAMETER DIFFERS FROM CORRE-SPONDING OWN CELL VALUE

The value of gprs_ms_txpwr_max of adjacent cell to be created or modified is different from the parameter value in the own cell.

15003 GPRS_ENABLED OF ADJACENT CELL DIFFERS FROM CORRE-SPONDING OWN CELL VALUE

The value of gprs enabled of adjacent cell to be created or modified is different from the parameter value in the own cell.

15004 HCS_THR OF ADJACENT CELL DIFFERS FROM CORRESPOND-ING OWN CELL VALUE

The value of hcs threshold of adjacent cell to be created or modified is different from the parameter value in the own cell.

Page 353: DX Error Messages

DN987378Issue 24-0

353

General Error Messages of System DX error messages

Id:0900d8058077e097

15005 PRIORITY CLASS OF ADJACENT CELL DIFFERS FROM CORRE-SPONDING OWN CELL VALUE

The value of priority class of adjacent cell to be created or modified is different from the parameter value in the own cell.

15006 CELL RELATED TO LA FOUND

The requested operation is not allowed, because the cell is related to LA.

15007 COMPUTER ALREADY EXISTS

The operation could not be completed since the specified computer already exists.

15008 MESSAGING GROUPS ARE INCONSISTENT

The operation resulted in a configuration of messaging groups that does not necessarily satisfy all the contracts made between the different components of the messaging group configuration management.

15009 MESSAGING GROUP DID NOT EXIST

The messaging group did not exist before the operation.

15010 MESSAGING GROUP IS EMPTY

The operation resulted in an empty messaging group, or the operation could not be completed since the messaging group is empty.

15011 MESSAGING GROUP IS FULL

The operation resulted in a full messaging group, or the operation could not be completed since the messaging group is full.

15012 MESSAGING GROUP WARNING THRESHOLD EXCEEDED

The operation resulted in a messaging group which size exceeded the warning threshold value.

15013 NO FREE HOST COMPUTERS

The operation could not be completed since there is no free host com-puters.

15014 NO ORPHAN COMPUTERS

The operation could not be completed since there is no orphan comput-ers.

15015 HOST COMPUTER DOES NOT EXIST

The operation could not be completed since the host computer does not exist.

15016 INTERFACE COMPUTER DOES NOT EXIST

The operation could not be completed since the interface computer does not exist.

15017 TOO MANY HOST COMPUTERS

The operation could not be completed since there are too many host computers.

15018 CELL IDENTIFIER IS NOT UNIQUE IN THE RNC

Page 354: DX Error Messages

354 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Cell identifier (cid) must be unique under the RNCs. There is some other cell with the same id in the same RNC.

15019 EGPRS COMPACT OPTION IS NOT IN USE IN THE BSC

The EGPRS Compact option is not in use in the BSC.

15020 EGPRS CLASSIC OPTION IS NOT IN USE IN THE BSC

The EGPRS Classic option is not in use in the BSC.

15021 SOLSA OPTION IS NOT IN USE IN THE BSC

The solsa option is not in use in the BSC.

15022 SMLC OBJECT NOT FOUND IN RNW DATABASE

Serving Mobile Location Center has not been created into the RNW database. No other objects can be created before the SMLC object has been created.

15023 LCS ELEMENT NOT FOUND IN RNW DATABASE

The Location Service Element has not been created into the RNW data-base.

15024 RIT TRANSFER TABLE NOT FOUND IN RNW DATABASE

The Radio Interface Timing Transfer Table has not been created into the RNW database.

15025 LMU AREA NOT FOUND IN RNW DATABASE

The Location Measurement Unit area has not been created into the RNW database.

15026 REPEATER NOT FOUND IN RNW DATABASE

The Repeater has not been created into the RNW database.

15027 EFFECTIVE ADMIN STATE IS NOT UNLOCKED FOR TP

The effective administrative state for the external termination point is not unlocked. This means that at least one of the objects (interface and tps) is not unlocked. If it is a VP-level termination point, check that the interface and VPLtp are unlocked. If it is a VC-level termination point, check that the interface and tps are unlocked.

15028 THE MESSAGING GROUP DID NOT EXIST

The messaging group did not exist before the operation.

15029 THE STATUS FIELD IS NOT APPLICABLE

The error status field can be ignored by the User interface and it should not be shown to the user. The status field is not applicable in this case.

15030 ONE OR MORE OF THE SIGNALLED AAL2 LINK CHARACTERIS-TICS PARAMETERS HAS A ZERO VALUE

All of the signalled AAL2 link characteristics parameters must have nonzero value.

15031 THE LAN MESSAGE GROUP FILE IS CORRUPTED

The LAN message group file is corrupted.

15032 TSC VALUES MUST BE EQUAL IN BB-HOPPING LAYER

Page 355: DX Error Messages

DN987378Issue 24-0

355

General Error Messages of System DX error messages

Id:0900d8058077e097

TSC values of all unlocked TRXs must be equal in BB-hopping layer underBTS.

15033 INVALID AAL2 QOS CONFIGURATION FOR N_CID VCC ENDPOINT

The selected AAL2 QoS configuration for the N_CID VCC endpoint is not valid. Check the combination of AAL2 multiplexing delay and VCC rate (allowed delay must be larger than one cell period).

15034 INTERNAL CROSS CONNECTION CREATION FAILED

Attempt to create internal cross connection failed because connection control rejected the request.

15035 LOCATION AREA IDENTIFIER DOES NOT BELONG TO ANY RANGE

The given LA ID does not lie in any defined LA ID range.

15036 NEW LA ID RANGE CANNOT BE ADDED TO THIS DXT BECAUSE THE MAX NUMBER IS REACHED

The number of LA ID ranges for one DXT is limited. When the maximum number is reached, new LA ID range cannot be added any more.

15037 GIVEN LA ID RANGE EXISTS ALREADY

The given LA ID range exists already, so it cannot be added again.

15038 LA ID RANGE OVERLAPS WITH AN EXISTING RANGE

The given LA ID range overlaps with another existing range, so it cannot be added.

15039 GIVEN LA ID RANGE DOES NOT EXIST

The given LA ID range does not exist.

15040 PREREQUIREMENTS OF THE INTERNAL CROSS CONNECTION ARE NOT FULFILLED

Internal cross connection was not created because the prerequire-ments, which are defined for the internal cross connections, have not been fulfilled.

15041 RESOLVING OF A FUNCTIONAL UNIT FAILED

Functional unit could not be resolved with the given information.

15042 CREATION OF A PREDETERMINED CROSS CONNECTION HAS FAILED

Creation of a predetermined cross connection has failed.

15043 CREATION OF AN INTERNAL INTERFACE HAS FAILED

Creation of an internal interface has failed.

15044 ALL THE NEEDED RESOURCES COULD NOT BE TAKEN INTO USE

Resources that are crucial for the normal functioning could not be taken into use.

15045 RADIO NETWORK UPDATED PARTLY SUCCESSFULLY

In case of two modification messages the first operation to update RNW db succeeded but the second operation failed. This error code is used for informing NMS about partially succeeded RNW update operation.

15046 ERROR IN INFORMING SOME PROCESS ABOUT CHANGE IN RNW

Page 356: DX Error Messages

356 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Some process, which needs information about the performed radio network configuration change, could not be updated successfully. More information can be found in DX-log.

15047 GIVEN VALUE IS TOO BIG

Interface, VPI or VCI value exceeds defined limit.

15048 GIVEN VCI VALUE IS RESERVED

Given VCI value is reserved for a special purpose.

15049 LSA ID LIST IS FULL

There is no room for more LSA IDs on the LSA ID list.

15050 GPRS IS NOT ENABLED IN ADJACENT CELL

GPRS must be enabled for ADJACENT CELL when adding LSA IDs to it.

15051 ADJACENT CELL IS IN OWN BSS

The adjacent cell cannot be in own BSS.

15052 TOO MANY AMR CODECS DEFINED

The user has defined too many AMR CODECS for the BTS.

15053 NOT ENOUGH THRESHOLDS DEFINED

Some AMR CODEC threshold values are missing.

15054 INVALID AMR START MODE

The AMR CODEC set does not support the given AMR START MODE.

15055 THRESHOLD OR HYSTERESIS VALUE IS INVALID

The given THRESHOLD and/or HYSTERESIS values do not conform with parameter semantics.

15056 FAILURE IN ATM LAYER DELETION

The ATM layer deletion was not completed successfully.

15057 SERVICE RELEASE FAILED - NO SUCH SERVICE

An unexisting service identifier is used in a release operation - no such signal processing service exists.

15058 LCS ELEMENT THAT IS A REFERENCE LCSE CANNOT BE DELETED

This LCS element cannot be deleted because it is defined as a refer-ence LCS element for some LMU area(s).

15059 LCS ELEMENT THAT IS AN SMLC GATEWAY CANNOT BE DELETED

This LCS element cannot be deleted because it is defined as SMLC gateway for some RIT transfer table(s).

15060 BTS GENERATION DOES NOT SUPPORT PBS FEATURE

The BTS generation (as read from database) does not support the usage of LMU area for Position Based Services.

15061 BTS GENERATION DOES NOT SUPPORT BSS SYNCHRONIZA-TION

Page 357: DX Error Messages

DN987378Issue 24-0

357

General Error Messages of System DX error messages

Id:0900d8058077e097

The BTS generation (as read from database) does not support the usage of LMU area for BSS synchronization.

15062 BTS SOFTWARE DOES NOT SUPPORT PBS FEATURE

The BTS software level (as read from database) does not support the usage of LMU area for Position Based Services.

15063 BTS SOFTWARE DOES NOT SUPPORT BSS OR SITE SYNCHRONI-ZATION

If LMU area modification or creation is in case, BTS software level in database does not support the usage of LMU area for BSS synchroni-zation. If BCF UNLOCK is in case, BTS software level in database does not support usage of the BCF for BSS or Site synchronisation, if Recovery for BSS and Site Synchronization feature (BSS11073) is enabled for the BCF.

15064 CANNOT MODIFY REF LCSE BECAUSE IT IS DEFINED AS SMLC GW

The reference LCS element cannot be modified because it is defined as SMLC gateway in some RIT transfer table(s).

15065 CANNOT REMOVE LCSE FROM MEASURED LCSES OR REF LCSE BECAUSE IT IS SMLC GW

The LCS element cannot be removed from the measured LCS elements list or from reference LCS element attribute because the LCS element is defined as SMLC gateway in some RIT transfer table(s).

15066 SMLC GATEWAY DOES NOT BELONG TO ANY LMU AREA

The given SMLC gateway is not included in any LMU area in own BSC.

15067 LCS ELEMENT LIST IS FULL

When adding LCS elements to the LCSE list the maximum number of list items was exceeded.

15068 NO RESPONSE TO ATM ENDPOINT SERVICES

There was no response to the ATM endpoint group or ATM endpoint handling service request.

15069 ATM ENDPOINT HANDLING SERVICE NOT FOUND

The service for handling the ATM endpoint group or ATM endpoint was not found.

15070 OTHER COCOS ALSO USING THE VPLTP

There are several Connection configuration sets using the same VPLtp. Modification of the VPLtp is not allowed.

15071 NO RESPONSE FROM GLPPRB

No response has been received from the GLPPRB.

15072 NO RESPONSE FROM SL1PRB

No response has been received from the SL1PRB.

15073 NO RESPONSE FROM GIGPRB

No response has been received from the GIGPRB.

Page 358: DX Error Messages

358 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15074 GPRS IS DISABLED IN THE CELL

The GPRS is disabled in the cell.

15075 NSEI NOT FOUND FROM ROUTING AREA

The NSEI in question cannot be found in the Routing Area the cell is using.

15076 VPLTP USED BY SEVERAL BTS, MODIFICATION NOT ALLOWED

The VPLtp is used by several BTSs. The modification is not allowed in order to avoid causing traffic losses to other BTSs.

15077 THE PROVIDER OF THE SERVICE IS NOT ANSWERING TO THE SERVICE REQUEST

The service provider is not answering to the service request. Try again later.

15078 ERROR WHILE CALLING MATH LIBRARY

Math library call has set into errno variable a non zero value in order to indicate that an error has taken place while executing the math function.

15079 FS CONSTRUCTION FAILED

The file system construction failed. The requested file system might be invalid for the device in question or the medium might be invalid.

15080 DISK LABEL CREATION FAILED

Creation of the disk label failed. The device or the medium might be out of order.

15081 FAILURE IN USING ADDRESS CONVERSION SERVICE

BRTSEB cannot use address conversion service. Reason for failure may be for example that address conversion service is not found from the name server.

15082 NSEI PARAMETER GIVEN WITHOUT GPRS ENABLED PARAME-TER

The NSEI parameter cannot be given without the GPRS enabled parameter.

15083 ADAPTIVE MULTIRATE CODEC OPTION IS NOT IN USEIN BSC

Adaptive multirate codec option is not in use in BSC.

15084 FRAME ERASURE RATE OPTION IS NOT IN USE IN BSC

Frame erasure rate option is not in use in BSC.

15085 ENHANCED GPRS FEATURE IS NOT IN USE IN BSC

Enhanced General Packet Radio Service feature is not in use in BSC.

15086 ENHANCED GPRS COMPACT OPTION IS NOT IN USE IN BSC

Enhanced General Packet Radio Service Compact option is not in use in BSC.

15087 ENHANCED GPRS CLASSIC OPTION IS NOT IN USE IN BSC

Enhanced General Packet Radio Service Classic option is not in use in BSC.

15088 DYNAMIC ABIS SUPPORT OPTION IS NOT IN USE IN BSC

Page 359: DX Error Messages

DN987378Issue 24-0

359

General Error Messages of System DX error messages

Id:0900d8058077e097

Dynamic Abis support in BSC option is not in use in BSC.

15089 COMMON BCCH GSM900 OPTION IS NOT IN USE IN BSC

Common BCCH GSM900 option is not in use in BSC.

15090 COMMON BCCH EGSM900 OPTION IS NOT IN USE IN BSC

Common BCCH EGSM900 option is not in use in BSC.

15091 COMMON BCCH GSM1800 OPTION IS NOT IN USE IN BSC

Common BCCH GSM1800 option is not in use in BSC.

15092 S3ADMI BUSY

The program block S3ADMI is not capable of receiving new tasks. Try again later.

15093 NO FREE RECORDS IN S3FILE FILE

No free records in S3FILE file.

15094 ASSOCIATION SET ALREADY EXISTS

The given association set already exists.

15095 ASSOCIATION SET DOES NOT EXIST

The given association set does not exist.

15096 ASSOCIATION SET IS IN USE

The given association set is in use.

15097 DATA MISMATCH BETWEEN S3FILE AND S3WORK FILES

Data mismatch between S3FILE and S3WORK files.

15098 ASSOCIATION DOES NOT EXIST

The given association does not exist.

15099 ASSOCIATION SET IS FULL

The association set has already the maximum number of associations.

15100 STATE OF ASSOCIATION IS INCORRECT

The state of the association is unknown or otherwise unfit for the situa-tion.

15101 INCOMPATIBLE NETMASK LENGTH

Incompatible netmask length. For example in the same association set all associations must have the same netmask length.

15102 UNIT ALREADY HAS ASSOCIATION

There can be only one association per association set in same unit.

15103 LCS ELEMENT WITH GIVEN LAC-CI ALREADY EXISTS.

There is already an LCS element with the given LAC-CI in the database.

15104 ORPHAN INTERFACE COMPUTERS REMAINING

(Some) interface computers remained orphan after messaging groups were reorganized.

15105 DAC MEASUREMENT OPTION IS NOT IN USE IN BSC

Option DacMeasurement is not in use in the BSC.

15107 GIVEN ALARM INPUT IS NOT IN USE

Page 360: DX Error Messages

360 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An attempt has been made to close an external alarm input that is already closed, or to change the characteristics of a closed external alarm input.

15108 EHAT DOES NOT EXIST

A task that requires the presence of EHAT plug-in unit in the system has been assigned when there is no EHAT in the hw-configuration.

15109 INTERNAL LAN HAS ALREADY BEEN CREATED

Internal LAN has already been created.

15110 INTERNAL LAN DOES NOT EXIST

Internal LAN does not exist.

15111 INTERNAL LAN TO BE REMOVED CONTAINS UNIT(S)

Internal LAN to be removed contains unit(s).

15112 ALL IP ADDRESSES OF INTERNAL LAN ARE RESERVED.

All IP addresses of the internal LAN have already been reserved.

15113 LAUDAT FILE COULD NOT BE READ

LAUDAT file could not be read.

15114 SCDFLE FILE COULD NOT BE READ

SCDFLE file could not be read.

15115 SUBNET ADDRESS ALREADY IN USE WHEN CREATING AN INTERNAL LAN

Subnet address is already in use when creating an internal LAN.

15116 UNIT TO BE REMOVED IS NOT IN INTERNAL LAN

Unit to be removed is not in internal LAN.

15117 UNKNOWN UNIT TYPE

Unit type is unknown to recovery system.

15118 UNKNOWN TASK TYPE

Internal LAN manager has received an unknown request type.

15119 UPDATING OF LAUDAT FILE FAILED

Updating of LAUDAT file failed.

15120 INTERNAL LAN TOPOLOGY DATA INQUIRY FAILED

For some reason the inquiry of Internal LAN topology data has failed.

15121 ILLEGAL SEARCH KEY COMBINATION USED

An illegal search key combination has been used when retrieving data about Internal LAN topology.

15122 INTERNAL LAN TOPOLOGY DATA SORT FAILED

The sorting of Internal LAN topology data has failed.

15123 INTERNAL LAN TOPOLOGY DATA NOT FOUND

Internal LAN topology data has not been found with this inquiry.

15124 GIVEN ALARM INPUT IS ALREADY IN USE

Page 361: DX Error Messages

DN987378Issue 24-0

361

General Error Messages of System DX error messages

Id:0900d8058077e097

An attempt has been made to open an external alarm input that is already in use.

15125 THE TRL ID IS NOT IN THE SET OF LINK IDS OF THE IMA GROUP

The Time Reference Link is not in the links of the IMA Group. Repeat the creation command using a Link ID for the TRL that is part of the IMA Group.

15126 CREATION OF AN INTERNAL LAN FAILED

Something went wrong when LAAGER program block tried to create an internal LAN.

15127 REMOVAL OF AN INTERNAL LAN FAILED

Something went wrong when LAAGER program block tried to remove an internal LAN.

15128 CREATION OF A UNIT TO INTERNAL LAN FAILED

Internal LAN manager program block (LAAGER) unsuccessfully tried to create a functional unit to internal LAN.

15129 REMOVAL OF A UNIT FROM INTERNAL LAN FAILED

Something went wrong when internal LAN manager program block (LAAGER) tried to remove a functional unit from internal LAN.

15130 SNMP STRING TO TYPE CONVERSION ERROR

Error occured during string to SNMP datatype conversion.

15131 SNMP TYPE TO STRING CONVERSION ERROR

Error occured during SNMP datatype to string conversion.

15132 SNMP AGENT DATA SET EXISTS ALREADY

The SNMP Agent Data Set is already existent.

15133 SNMP AGENT DATA SET NOT EXISTENT

The SNMP Agent Data Set does not exist.

15134 SNMP DATASET CONFIGURATION FILE ERROR

Error occured while opening the dataset configuration file.

15135 SNMP CONFIGURATION FILE ERROR

Error occured during SNMP configuration file opening.

15136 SNMP IPET EXISTS ALREADY

The SNMP IPET information is already existent.

15137 SNMP IPET NOT EXISTENT

The SNMP IPET information does not exist.

15138 SNMP INVALID UNIT TYPE

The SNMP unit type information is invalid.

15139 SNMP READ-ONLY NUMBER LIMIT EXCEEDED

The maximum SNMP read-only number limit of 3 has been exceeded.

15140 SNMP READ-WRITE NUMBER LIMIT EXCEEDED

The maximum SNMP read-write number limit of 3 has been exceeded.

15141 SNMP SECURITY NUMBER LIMIT EXCEEDED

Page 362: DX Error Messages

362 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The maximum SNMP security number limit of 1 has been exceeded.

15142 NO SNMP AGENT DATA SETS EXISTENT

There are no SNMP Agent Data Sets existent.

15143 NO SNMP IPETS EXISTENT

There are no SNMP IPETs existent.

15144 SNMP AGENT DATA SET HAS NO COMMUNITY STRING INFORMA-TION

The SNMP Agent Data Set has no community data information.

15145 SNMP IPET HAS NO COMMUNITY STRING INFORMATION

The SNMP IPET has no community string information.

15146 SNMP AGENT DATA SET HAS NO TRAP DESTINATION DATA

The SNMP Agent Data Set has no trap destination data.

15147 SNMP IPET HAS NO TRAP DESTINATION DATA

The SNMP IPET has no trap destination data.

15148 SNMP DATASET CONFIGURATION FILE LIMIT HAS BEEN EXCEEDED

The maximum SNMP dataset configuration file limit of 20 has been exceeded.

15149 SNMP IPET CONFIGURATION FILE LIMIT HAS BEEN EXCEEDED

The maximum SNMP IPET configuration file limit of 1000 has been exceeded.

15150 SNMP TRAP DESTINATION NUMBER EXISTS ALREADY

The given trap destination number was already existent.

15151 SNMP COMMUNITY STRING NUMBER EXISTS ALREADY

The given community string number is already existent.

15152 SNMP ACCESS MODE IS INVALID

The SNMP access mode is invalid.

15153 SNMP COMMUNITY NUMBER DOES NOT EXIST

The SNMP community number is not existent.

15154 LA ID NOT WITHIN DEFINED LA ID RANGE(S)

The given location area identifier is not within any location area identifier range(s) defined for the DXT.

15155 NO FREE LOCATION AREA IDENTIFIER AVAILABLE

This error message is used when trying to add a location area and there is no free location area identifiers within the ranges left for addition or there is no range defined for the DXT.

15156 IPETS NOT CONFIGURED

IPETS is not configured.

15157 FQDN NOT CONFIGURED

FQDN is not configured.

15158 FQDN ALREADY IN USE

Page 363: DX Error Messages

DN987378Issue 24-0

363

General Error Messages of System DX error messages

Id:0900d8058077e097

FQDN is already in use.

15159 INCORRECT ROUTE COUNT

The route count is incorrect.

15160 ROUTE LINKED

The route is linked.

15161 APPROACHED HMS MASTER NODE IS NOT ACTIVE

An attempt has been made to assign a task which requires that the service provider is in the active HMS master node to a service provider which is not in the active HMS master node.

15162 ECSD OPTION IS NOT IN USE IN THE BSC

Enhanced Circuit Switched Data option is not in use in BSC.

15163 FR BEARER CHANNELS EXIST ON PCM, CHECK THAT THEY ARE NOT USED

FR Bearer channels exist on this PCM, check that they are not used.

15164 SIZE OF THE DYNAMIC ABIS POOL IS INCORRECT

Size of the dynamic abis pool is incorrect.

15165 THERE IS ONE OR MORE TRXS ATTACHED TO THE DYNAMIC ABIS POOL

Dynamic Abis pool has TRX(s) attached.

15166 NO MORE DYNAMIC ABIS POOLS CAN BE ATTACHED TO THE SAME PCU

The maximum number of Dynamic Abis pool allowed in the Packet Control Unit has been reached.

15167 THERE IS NO ROOM FOR THE DYNAMIC ABIS POOL IN THE PCU

There is no room for Dynamic Abis pool in the Packet Control Unit.

15168 SPRM ALLOCATED SERVICE ID IS WRONG IN MESSAGE

SPRM allocated service ID related to this resource is wrong.

15169 WRONG PARAMETER IN LAYER 2 SETUP MESSAGE

Some of the parameters is wrong in layer 2 setup message.

15170 LAYER 2 P2PSEBQX INTERNAL ERROR

Internal P2PSEBQX layer 2 error.

15171 RLC RESET PROCEDURE FAILED.

RLC reset prosedure failed.

15172 SDU DISCARD WAS PERFORMED.

SDU discard was performed.

15173 TRANSMISSION BUFFER OVERFLOW OCCURRED (ON CONTROL PLANE).

Transmission buffer overflow occurred (on Control Plane).

15174 GIVEN RLC CONNECTION NUMBER WAS UNKNOWN.

Given RLC connection number was unknown.

15175 RLC MOVE RECEIVING WINDOW PROCEDURE FAILED.

Page 364: DX Error Messages

364 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

RLC move receiving window procedure failed.

15176 THE VALUE OF BIT 0X1 IN SPECIAL HANDLING FIELD WAS NOT ACCEPTABLE IN RLC

SDU was not accepted because the value of bit 0x1 in special handling field in rfu_c_dl_sdu_s was not acceptable (on Control Plane).

15177 RLC TRANSMISSION AND RETRANSMISSION BUFFERS ARE EMPTY.

Transmission and retransmission buffers are empty. This status will be sent only if bit 0x4 in rfu_c_dl_sdu_s was set in the last SDU.

15178 RLC CONTROL COMMAND NOT SUPPORTED

RLC control command is not supported.

15179 COMMAND TO STOP RLC ENTITY IN SOURCE RNC DURING SRNS RELOCATION WAS SUCCESSFUL.

Command to stop RLC entity in source RNC during SRNS relocation was successful.

15180 COMMAND TO STOP RLC ENTITY IN SOURCE RNC DURING SRNS RELOCATION WAS UNSUCCESSFUL.

Command to stop RLC entity in source RNC during SRNS relocation was unsuccessful.

15181 SRNS RELOCATION WILL BE DONE AND RLC ENTITY IS NOT STOPPED

Command to tell RLC entity in source RNC that SRNS relocation will be done, but this entity is not stopped. Command executed successfully.

15182 SRNS RELOCATION IN SOURCE RNC NOT SUCCESSFUL IN RLC LAYER.

SRNS relocation in RLC layer was not successful.

15183 COMMAND TO STOP RLC ENTITY IN TARGET RNC DURING SRNS RELOCATION WAS SUCCESSFUL.

Command to stop RLC entity in target RNC during SRNS relocation was successful.

15184 COMMAND TO STOP RLC ENTITY IN TARGET RNC DURING SRNS RELOCATION WAS UNSUCCESFUL.

Command to stop RLC entity in target RNC during SRNS relocation was unsuccessful.

15185 COMMAND TO PUT RLC ENTITY BACK TO NORMAL STATE WAS SUCCESSFUL.

Command to put RLC entity back to normal state from special state caused by command STOP, SRNS_REL or TARG_STOP. Command was successful.

15187 COMMAND FOR AM RLC ENTITY TO MAKE RESET WAS SUC-CESSFUL.

Command for AM RLC entity to make reset was successful.

15189 DXL ID WRONG IN OUTER LOOP POWER CONTROL SETUP REQUEST.

Page 365: DX Error Messages

DN987378Issue 24-0

365

General Error Messages of System DX error messages

Id:0900d8058077e097

DXL id wrong in outer loop power control setup request.

15190 COMMAND FOR AM RLC ENTITY TO MAKE RESET WAS UNSUC-CESSFUL.

Command for AM RLC entity to make reset was unsuccessful.

15191 THE NEW APN INDEX CAN NOT BE ADDED BECAUSE IT ALREADY EXISTS IN THE DATABASE.

All apn index numbers must be unique throughout the system. There-fore it is not possible to have the same apn index for two different apns.

15192 THE NEW APN CAN NOT BE ADDED BECAUSE IT ALREADY EXISTS IN THE DATABASE

All apns must be unique. If an apn already exists in the database then it is not possible to add it into the database again

15193 THE APN POOL IS NOT FOUND IN THE DATABASE

All apn pools are identified by names. If that name can not be found in the database then an error is returned

15194 THE NEW APN POOL CAN NOT BE ADDED BECAUSE IT ALREADY EXISTS IN THE DATABASE

All apn pools must be unique. If an apn pool already exists in the database then it is not possible to add it into the database again.

15195 THE APN CAN NOT BE FOUND IN THE DATABASE

The apn is not in the database and so it is not possible to perform the assigned operation on it.

15196 THE ORGANISATION BLOCK HAS A STATIC APN ASSIGNED TO IT IN THE DATABASE

All organisation blocks can be assigned a static apn. A new apn can not be assigned to the organisation block until the old apn is deassigned

15197 THE DATA SERVICE IS NOT ACTIVATED FOR THIS SUBSCRIBER

The data service is not activated for this subscriber, so they can not use packet data functions.

15198 THE SUBSCRIBER HAS NO IMSI ASSIGNED IN THE DATABASE

A subscriber uses an imsi for packet data. The subscriber has not been assigned an imsi.

15199 SEG WITH SEVERAL BTS IS NOT ALLOWED FOR THIS BTS SITE TYPE

This BTS site type does not support segments with several BTS objects.

15200 GPRS ENABLED TRX CANNOT BE SUPER-REUSED

A GPRS enabled TRX cannot be super-reused.

15201 GPRS ENABLED TRX CANNOT BE E-TRX OR S-TRX WITHOUT EGTCH

GPRS ENABLED TRX CANNOT BE E-TRX OR S-TRX WITHOUT EGTCH

15202 GIVEN LA ID RANGE IS NOT VALID

Page 366: DX Error Messages

366 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Given LA ID range is not valid if the end value is smaller than start value or the values are not in the scope 0-16383.

15203 SNMP TRAP DESTINATION NUMBER ALREADY EXISTS.

The given trap destination number already exists.

15204 SNMP TRAP DESTINATION NUMBER DOES NOT EXISTS

The given trap destination does not exist.

15205 SNMP AGENT MODIFICATION NOT ALLOWED

The SNMP Agent is not allowed to perform modification.

15206 ADJS ALREADY CREATED UNDER WCEL

An Intra Frequency Adjacency (ADJS) object with the given id entity is already created under given WCEL id in radio network database.

15207 SNMP ADDING COMMUNITY DATA NOT ALLOWED

The given community data is not allowed to be added.

15208 SNMP ADDING TRAP DESTINATION DATA NOT ALLOWED

The given trap destination is not allowed to be added

15209 THE NSEI MUST BE THE SAME AS THE NSEI OF THE DYNAMIC ABIS POOL

The NSEI given by the user must be the same as the NSEI (PCU) defined for the Dynamic Abis Pool which the TRXs of the cell are using.

15210 THE FAMILY IS BEING DELETED

The operation can not be completed since the specified family is being deleted.

15211 DATA PROVIDER HAS LOST SYNCHRONISATION

Data provider has lost synchronisation and it can request new synchro-nisation by using this status.

15212 OPERATIONAL STATE OF THE INTERFACE IS NOT ENABLED

The operational state of the target interface is not enabled.

15213 UNIT DOES NOT EXIST IN GIVEN INTERNAL LAN

The given unit does not exist in this particular LAN. Check whether it exists in some other LAN.

15214 NO ANSWER FROM INTERFACE UNIT

Supervision program block of interface unit has failed to respond within time supervision.

15215 HOP IS USED BY SOME ADJ

HOP cannot be deleted, because it is used by some adjacency (ADJ).

15216 INCORRECT CGR COUNT

Incorrect CGR count

15217 SP RESTART IS IN PROGRESS

SP restart situation is in progress.

15218 CELL IS ATTACHED TO DCCH LIST

A cell is attached to the DCCH list. The DCCH list cannot be deleted.

Page 367: DX Error Messages

DN987378Issue 24-0

367

General Error Messages of System DX error messages

Id:0900d8058077e097

15219 TWO DCCH LISTS ALREADY ATTACHED TO THE CELL

There are already two DCCH lists attached to the cell.

15220 ILLEGAL HYPERBAND OF SECOND DCCH LIST OF CELL

The second DCCH list attached to the cell has to be of different hyper-band than the first one.

15221 RNW PLAN OPERATION HISTORY NOT FOUND (RNC OMU)

RNW Plan manager program block has not been able to collect history inrormation on the requested RNW Plan operation.

15222 INCONSISTENT LOGICAL NAME AND HMSI

Logical name and HMSI are inconsistent.

15223 LOGICAL NAME WAS NOT CREATED

Logical name was not created.

15224 SPD WAS NOT UPDATED

SPD was not updated.

15225 PARAMETERS IN ADJ DEFINITION DO NOT MATCH WITH TARGET CELL

ADJ has some parameters which should be consistent with the corre-sponding parameters defined in target cell.

15226 AAL2 NODAL FUNCTION ROUTING ERROR

User plane application set this error code in Nodal Function feature, if Digit Analysis, outgoing resource reservation or through connection fails.

15227 INCORRECT SEQUENCE NUMBER OF LOG BUFFER

Sequence number of database log buffer is not correct.

15228 CONGESTION IN THE AAL5 LAYER TX BUFFER

This error code is returned by AIHLIB routine aap_send_data_r when the amount of messages in transmit buffer exceeds set threshold level.

15229 UNIT IS IN MINIDEBUGGER STATE

Unit is in minidebugger state i.e. in a state to which you can set the computer after booting. In a minidebugger state, the programs loaded in boot loading and specified as part of the minidebugger build are started. The start-up of the computer no longer proceeds locally; for instance the initial loading is not started.

15230 UNIT IS IN DEBUGGER STATE

Unit is in debugger state i.e. in a state into which you can set the computer after the initial loading. In the debugger state, only some of the programs loaded during the initial loading are started. The ones that are not started include the programs controlling the local start-up, which means that the start-up of the computer stops.

15231 HMS SEPARATION FAILED

Separation of the hms failed.

15232 HMS DESEPARATION FAILED

Page 368: DX Error Messages

368 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Deseparation of the hms failed.

15233 MASTER SWITCHOVER FAILED

Switchover of the hms master failed.

15234 TRANSMISSION LINE SWITCHOVER FAILED

Switchover of the hms transmission line failed.

15235 SSI USED BY GROUP OVERLAY

The SSI is used by a group overlay.

15236 RESOURCES ALLOCATED TO GATEWAY COMPUTER

A gateway computer that acts as a host to at least one interface computer has resources allocated to it.

15237 NO RESOURCES ALLOCATED TO GATEWAY COMPUTER

A gateway computer that has no interface computers attached to it does not have any resources.

15238 TRX D-CHANNEL IS ON DIFFERENT PCM THAN DYNAMIC ABIS POOL

Dynamic Abis pool and the TRX D-channel must be located in the same ET-PCM.

15239 FIXED AND DYNAMIC ALLOCATION USED IN BTS

TRXs under the same BTS can use either fixed or Dynamic Abis alloca-tion,not both.

15240 GIVEN DYNAMIC ABIS POOL USES INCORRECT PCU

All TRXs under a cell must use the same PCU.

15241 NO SUCH FILE GROUP

The requested file group was not found.

15242 NO FREE FILE GROUP INDEX

A new backup cannot be copied to FDU, because the maximum amount of file groups exist already.

15243 INCORRECT SOURCE FOR BACKUP COPYING

Updating an existing backup is allowed only from the same source as theoriginal.

15244 DCCH LIST NOT ATTACHED TO THE CELL

There has to be at least one DCCH Pointer list attached to the BCCH (CPBCCH/PBCCH) Cell.

15245 E-TRX OR S-TRX IS NOT UNDER BCCH-BTS IN THE CELL

E-TRX OR S-TRX IS NOT UNDER BCCH-BTS IN THE CELL

15246 ILLEGAL BCCH DEFINITION IN CELL,BCCH IS ON ILLEGAL BAND

If cell contains different frequency bands, BCCH must be on PGSM900 or EGSM900 band.

15248 THERE IS ALREADY ANOTHER ADJ POINTING TO SAME TARGET UNDER THIS WCEL.

Two ADJ definitions pointing to same target WCEL is not allowed to be in same WCEL.

Page 369: DX Error Messages

DN987378Issue 24-0

369

General Error Messages of System DX error messages

Id:0900d8058077e097

15249 SOURCE AND TARGET WCELS MUST HAVE SAME FREQS IN ADJS (INTRA-FREQ ADJ)

Target WCELs frequency (uarfcn) differs from source WCELs fre-quency, so they can not be defined as intra-freq neigbours (ADJS).

15250 CONFIGURATION IN COMMON CHANNELS IS NOT CORRECT.

Configuration in common channels (PRACH / SCPCCH) is not as correct. Some physical or logical channels can be missing or they are wrongly configured.

15251 LOGICAL CCH CONFIGURATION IN PHYSICAL CHANNELS MAY NOT BE CHANGED IF WCEL UNLOCKED

The configuration of logical common channels (ids and existence) may not be changed in physical channel if the WCEL state is not locked. Other logical channel parameters (except id) can be modified.

15252 IT IS NOT ALLOWED TO CHANGE FIRSTTSL AND LASTTSL AT THE SAME PRIMITIVE.

It is not allowed to change firstTsl and lastTsl at the same primitive.

15253 INCORRECT UNIT INDEX

The unit index is incorrect. The units by given type must be created into the equipment database in the ascending order indicated by their indexes.

15254 COMMON CHANNEL IDENTIFIERS MUST BE UNIQUE IN WCEL.

Physical common channels (identifiers) must be unique within WCEL. Also logical channels must be unique within WCEL.

15255 NO FREE BDS FOR CHANNEL

Allocation for channel buffer descriptors failed; No resource

15256 NO SUCH SERVICE ID

Given service id not found.

15257 NO SUCH SERVICE

Unknown service type in request.

15258 UNRESERVED CHANNEL IN REQUEST

The given channel not found from the list of reserved, unused channels.

15259 REPLY FROM DSP NOT RECEIVED / TIMEOUT

Reply from DSP application not received on time.

15260 DATA DRIVER NOT FOUND FROM NAME SERVER

Error encountered when trying to enquire for the port name of DSP data driver.

15261 CONTROL CHANNEL TP NOT CONNECTED

Control channel tp to be modified is found from control channel man-agement but the channel is down at the moment, i.e. there are no control channel connection to be modified. The control channel resources are however tried to be set again to working automatically by control channel management after a while.

15262 RNC IDENTIFIER MAY NOT BE CHANGED

Page 370: DX Error Messages

370 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The identifier of RNC may not change.

15263 FHO_START_AS SERVICE NOT AVAILABLE

The service fho_start_as is not found from the system.

15264 THE ROUTING AREA IS BEING USED BY A GPRS ENABLED CELL

The routing area cannot be deleted because it is being used by a GPRS enabled cell.

15265 THE NUMBER OF IPSA PROVIDERS IS EXCEEDED

There are too many ipsa providers.

15266 SSRI DOES NOT EXIST

The SSRI does not exist.

15267 REPORTING OF INTERNAL INTERFACE FAILED

Failure when JIGGER is reporting internal interface to PIGPRB.

15268 TOO MANY PACKET CONTROL CHANNELS IN TRX

Only one packet control channel is allowed in TRX.

15269 SCTP IS IN ILLEGAL STATE

SCTP is in a state where it cannot send user messages.

15270 ILLEGAL STREAM ID

Stream id is illegal.

15271 NO TCB FOUND FOR AN ASSOCIATION

TCB is not found for an association.

15272 NO FREE TCB FOUND

No free TCB found.

15273 SCTP PORT ALREADY IN USE

The given SCTP port is in use.

15274 SCTP PORT NOT FOUND

The given SCTP port is not found.

15275 SCTP PORT USER TABLE IS FULL

SCTP port user table is full.

15276 LOCAL INSTANCE NOT FOUND FOR THE USER

Local SCTP instance not found. User is not initialized.

15277 UNRESOLVED ADDRESS

The IP address is unknown.

15278 SCTP OUT OF RESOURCE

The SCTP is out of resource.

15279 INVALID MANDATORY SCTP PARAMETER

The given parameter is invalid.

15280 ERROR IN VERIFICATION TAG

The verification Tag is invalid. Verification tag does not match to the given tag.

Page 371: DX Error Messages

DN987378Issue 24-0

371

General Error Messages of System DX error messages

Id:0900d8058077e097

15281 MISSING SCTP PARAMETER

Unknown or missing SCTP parameter.

15282 NO USER DATA

No user data.

15283 NO ACTIVE ADDRESS FOUND

No active active address is found.

15284 ASSOCIATION ID OUT OF RANGE

Association id out of range.

15285 SUBNETS ARE NO LONGER VALID IN THE CURRENT PACKET DATA SOFTWARE RELEASE LEVEL

The Subnet configuration is no longer required in the DXT network when packet data software level is release 3.0 or greater.

15286 THIS DXT IS NOT GROUP HLR

Group HLR operation is tried to an exchange that is not the home exchange for that group.

15287 TXRX LOOP TEST IS ALREADY ACTIVE

This error message is used when txrx loop test is already active in the base station.

15288 TXRX LOOP TEST RESULTS NOT FOUND

This error message is used when the txrx loop test results are not found. Results do not exist if the rx branch does not carry out a test success-fully.

15289 ENCRYPTION KEY DELIVERY TO BS FAILED

Encryption key delivery to base station failed.

15290 COMMON CIPHER KEY SEALING FAILED

Common cipher key sealing the MS delivery format failed.

15291 INTRA-FREQUENCY HANDOVER PATH PARAMETER SET ID VALUE IS TOO HIGH.

Intra-frequency handover path parameter set id value is too high.

15292 INTRA-FREQUENCY MEASUREMENT CONTROL PARAMETER SET ID HAS TOO HIGH VALUE.

Intra-frequency measurement control parameter set id has too high value.

15293 THE SPECIFIED WCDMA CELL DOES NOT EXIST.

The specified WCDMA cell does not exist.

15294 MAXIMUM NUMBER OF WCDMA CELLS UNDER RNC EXCEEDED.

Maximum number of WCDMA cells under RNC exceeded.

15295 THE SPECIFIED WCDMA CELL HAS ALREADY BEEN CREATED.

The specified WCDMA cell has already been created.

15296 THE SPECIFIED INTRA-FREQUENCY ADJACENT CELL HAS ALREADY BEEN CREATED.

Page 372: DX Error Messages

372 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The specified intra-frequency adjacent cell has already been created.

15297 MAXIMUM NUMBER OF INTRA-FREQUENCY ADJACENT CELLS EXCEEDED UNDER WCDMA CELL.

Maximum number of intra-frequency adjacent cells exceeded under WCDMA cell.

15298 THE SPECIFIED INTRA-FREQUENCY ADJACENT CELL UNDER WCDMA CELL DOES NOT EXIST.

The specified intra-frequency adjacent cell under WCDMA cell does not exist.

15299 INTRA-FREQUENCY HANDOVER PATH PARAMETER SET HAS ALREADY BEEN CREATED.

Intra-frequency handover path parameter set has already been created.

15300 INTRA-FREQUENCY HANDOVER PATH PARAMETER SET DOES NOT EXIST.

Intra-frequency handover path parameter set does not exist.

15301 INTRA-FREQUENCY MEASUREMENT CONTROL PARAMETER SET HAS ALREADY BEEN CREATED.

Intra-frequency measurement control parameter set has already been created.

15302 INTRA-FREQUENCY MEASUREMENT CONTROL PARAMETER SET DOES NOT EXIST.

Intra-frequency measurement control parameter set does not exist.

15303 WORKSTATION CLEAR LOGIN IS FORBIDDEN

Workstation login with clear password is forbidden.

15304 SUBSCRIBER IS NOT CURRENTLY REGISTERED IN THIS EXCHANGE

Subscriber record in VLR exchange database is not valid.

15305 GROUP OBJECT IS UNDER DELETION AND CANNOT BE USED ANYMORE.

Group object is under deletion and cannot be used anymore. Group number is still reserved until group is totally deleted.

15306 POFFIC MESSAGING IS ALREADY SUSPENDED

POFFIC cannot service suspend request yet because the messaging is already suspended by another request which has not yet been can-celed.

15307 PLUG-IN UNIT INDEX VALUE TOO HIGH

Value of the plug-in unit is too high. Check the index of the plug-in unit.

15308 THE SOAP MESSAGE DOES NOT CONFORM TO THE SOAP SPEC-IFICATION

The SOAP message does not conform to the SOAP specification.

15309 THE SOAP REQUEST NAME IS INVALID

The SOAP request name is invalid.

Page 373: DX Error Messages

DN987378Issue 24-0

373

General Error Messages of System DX error messages

Id:0900d8058077e097

15310 INVALID EH ATTRIBUTE NAME

Invalid EH attribute name.

15311 INVALID EVENTHANDLERIDENTIFIER VALUE.

Invalid eventHandlerIdentifier value. Either EHC file does not exist or EHC name and value of attribute eventHandlerIdentifier in EHC are dif-ferent.

15312 ATTRIBUTE ADMINISTRATIVESTATE NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute administrativeState not found or value of attribute is invalid.

15313 ATTRIBUTE TARGETIPADDRESS NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute targetIPAddress not found or value of attribute is invalid.

15314 ATTRIBUTE TARGETTCPPORTNUMBER NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute targetTcpPortNumber not found or value of attribute is invalid.

15315 ATTRIBUTE ABSOLUTEPATH NOT FOUND OR VALUE OF ATTRI-BUTE IS INVALID

Attribute absolutePath not found or value of attribute is invalid.

15316 ATTRIBUTE COMPRESSIONMETHOD NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute compressionMethod not found or value of attribute is invalid.

15317 ATTRIBUTE CONNECTIONCLOSINGTIMEOUT NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute connectionClosingTimeout not found or value of attribute is invalid.

15318 ATTRIBUTE RESPONSEWAITINGTIMEOUT NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute responseWaitingTimeout not found or value of attribute is invalid.

15319 ATTRIBUTE MAXIMUMBATCHSIZE NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute maximumBatchSize not found or value of attribute is invalid.

15320 ATTRIBUTE PACINGINTERVAL NOT FOUND OR VALUE OF ATTRI-BUTE IS INVALID

Attribute pacingInterval not found or value of attribute is invalid.

15321 ATTRIBUTE HEARTBEATNOTIFICATIONINTERVAL NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute heartbeatNotificationInterval not found or value of attribute is invalid.

15322 ATTRIBUTE NOTIFICATIONTIMELIMIT NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute notificationTimeLimit not found or value of attribute is invalid.

Page 374: DX Error Messages

374 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15323 ATTRIBUTE ACCEPTEDEVENTTYPES NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute acceptedEventTypes not found or value of attribute is invalid.

15324 ATTRIBUTE UPDATEINTERVAL NOT FOUND OR VALUE OF ATTRI-BUTE IS INVALID

Attribute updateInterval not found or value of attribute is invalid.

15325 ATTRIBUTE IDLEBEFORESAVING NOT FOUND OR VALUE OF ATTRIBUTE IS INVALID

Attribute idleBeforeSaving not found or value of attribute is invalid.

15326 LA ID RANGE RECOVERY HAS FAILED. THE RANGE MUST BE DELETED MANUALLY.

The addition of LA ID range has failed, and so has the resulting of auto-matic LA ID range recovery. The failures are due to a database malfunc-tion. The operator must delete the LA ID range manually.

15327 CLUSTER DOES NOT EXIST

No cluster was found that matches the given search criteria.

15328 FAX OR DATA CALL DETECTED IN MGW

Fax or data call detected in MGW.

15329 REQUESTED PCR DOES NOT FIT IN TO THE SCHEDULE TABLE

Requested PCR does not fit in to the schedule table.

15330 OAM SUPERVISION ALREADY ACTIVE

OAM supervision for requested atm interface already active.

15331 NO DMX MESSAGING FOR MULTIPLEXING UNIT

No internal interface exist for multiplexing unit.

15332 TRIBUTARY UNIT HAS NO INTERNAL INTERFACE

No internal interface exist for tributary unit.

15333 REMOVING OF D-CHANNEL FAILED BECAUSE IT IS IN USE

Removing of D-channel has failed because the link is used by TRX or BCF.

15334 FILE LOCKING OPERATION FAILED

An attempt to exclusively lock a file has failed.

15335 IP ADDRESS IS SHARED BY OTHER INTERFACE.

IP address is shared by other interface.

15336 TEST CAN NOT BE EXECUTED FOR THIS TYPE OF BTS IF BASEBAND FREQUENCY HOPPING IS USED

Test can not be executed for this type of BTS if baseband frequency hopping is used.

15337 PARAMETER PMAX1/PMAX2 MUST BE HIGHER THAN OR EQUAL TO PARAMETER PMIN

The values of the segment level parameters MS txpwr max gsm (PMAX1) and MS txpwr max gsm1x00 (PMAX2) must be higher than or

Page 375: DX Error Messages

DN987378Issue 24-0

375

General Error Messages of System DX error messages

Id:0900d8058077e097

equal to all the values of the BTS level parameters MS txpwr min (PMIN) in all the BTSs of the corresponding band in the segment.

15338 GIVEN ROUTINE PARAMETERS ARE INCORRECT

When CXMLIB notices that given parameters are incorrect it returns INVALID_PARAMETER_EC.

15339 CLIENT HAS NOT REGISTERED

If CXMLIB notices that the client has not registered it returns DMX_NOT_REGISTERED_EC to the client.

15340 NO RESPONSE FROM GCHPRB

No response has been received from the GCHPRB process.

15341 UNIT IS NOT IN EQUIPMENT DATABASE

Unit is not found from equipment database (EQUIPM) and/or Working State and Configuration File (SCDFLE). The unit cannot therefore be removed from intenal LAN management. - Create unit to EQUIPM - Remove unit from internal LAN - Remove unit from EQUIPM This situation should not occure. When unit is in internal LAN man-agement the unit should also be equipped to EQUIPM.

15342 OBJECT INCONSISTENT - PLEASE DELETE IT

The data of this object is inconsistent in the system. The only operation allowed is to delete the object.

15343 OAM SUPERVISION ALREADY PASSIVE.

OAM supervision for requested atm interface is already passive.

15344 ALL LUCENT APC SCHEDULERS ARE ALREADY ALLOCATED

All Lucent APC schedulers are already allocated.

15345 SCHEDULER FOUND BUT NO CLASSES LEFT

Scheduler was found but there were no classes left.

15346 ATM CAC HAS DETECTED INVALID PARAMETER IN THE SERVICE REQUEST

ATM CAC has detected invalid parameter in the service request.

15347 INCONSISTENT SCHEDULER MAPPING

Inconsistent scheduler mapping.

15348 THE GIVEN DATASET IS CONNECTED WITH IPET

The given dataset is connected with a IEPT(s), so it has to be removed before deletion.

15349 THE GIVEN DATASET IS CONNECTED WITH IPET(S)

The given dataset can not be deleted before the given dataset is removed from IPET(s).

15350 NO SUITABLE NSEI FOUND IN THE ROUTING AREA

The routing area of the cell does not contain any NSEI which can be used.

15351 CLUSTER TOPOLOGY NOT COMPLETE

Page 376: DX Error Messages

376 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Topology information of the requested cluster is not ready for distribu-tion.

15352 UNKNOWN CLUSTER

The requested cluster is unknown to PIGPRB.

15353 PHYSICAL LAYER TTP EXISTS ON GIVEN OBJECT

Physical layer trail termination point has been created on the given object. It can not be deleted or no new phyTTP can be created on it.

15354 PHYSICAL LAYER TTP WITH THE GIVEN ID HAS NOT BEEN CREATED

Physical layer trail termination point with the given id does not exist in the system.

15355 SDH VC PATH NUMBER IS OUT OF RANGE

SDH VC path number is not in the allowable range.

15356 PHYSICAL LAYER TTP ID IS OUT OF RANGE

Physical layer trail termination point id is not in the allowable range.

15357 ICELIB WAS NOT INITIALIZED BEFORE CALLING THE FUNCTION

The error code means that an application has called any ICELIB function without previously initializing the library with icelib_init_r.

15359 APC LUT MEMORY ALLOCATION/DEALLOCATION FAILED

The dynamic LUT memory allocation or deallocation failed. More details can be found in the log.

15360 OPENING THE EGRESS SIDE OF THE CONNECTION FAILED

An error occurred while reserving the resources for the egress side of a termination point. More details can be found in the log.

15361 TOPOLOGY SERVICE FAILS TO PROVIDE TOPOLOGY INFORMA-TION

Topology service returns an error code or failes to provide required information.

15362 CAC MEMORY POINTER ENTRY WAS NOT FOUND FROM THE MEMORY POINTER TABLE

CAC memory pointer was not found from the memory pointer table.

15363 CAC MEMORY POINTER TABLE IS FULL

CAC memory pointer table is full and no more entries can be added.

15364 OPENING THE INGRESS SIDE OF THE CONNECTION FAILED

An error occurred while reserving the resources for the ingress side of a termination point. More details can be found in the log.

15365 THE REQUESTED CELL RATE COULD NOT BE ALLOCATED

The cell rate requested by the user is not valid. A possible reason is that the rate exceeds the maximum rate allowed for the cell flow.

15366 THE APC INSERTION FIFO IS FULL

An attempt to insert a cell through the microprocessor interface of the APC has failed, because the insertion FIFO is full.

Page 377: DX Error Messages

DN987378Issue 24-0

377

General Error Messages of System DX error messages

Id:0900d8058077e097

15368 THE APC CAPTURE FIFO IS EMPTY

An attempt to capture a cell from the microprocessor interface of the APC has failed, because the capture FIFO is empty.

15369 THE TERMINATION POINT LOOKUP FAILED

An error occurred while translating the tp identification information (mphy, vpi, vci) to the APC driver internal indexing.

15370 THE APC EXTERNAL MEMORY ACCESS FAILED

Reading from or writing to the location of the APC external memory failed.

15371 DELAYED TEST INTERRUPTION STARTED

Delayed test interruption started. Timeslot under test is accomplished and interruption is started after that.

15372 INTERNAL ERROR IN RNW PLAN MANAGER PROGRAM BLOCK

RNW plan operation has been interrupted because of an internal error in plan management in RNC OMU.

15373 RNW PLAN MANAGER PROGRAM BLOCK BUSY

RNW plan operation has been rejected because of an unfinished earlier operation in RNC OMU.

15374 FAILURE IN RNW PLAN MANAGER PROGRAM BLOCK HAND RESERVING

Operating system in RNC OMU has returned an error code when RNW Plan Manager tried to reserve new hand for the RNW plan operation.

15375 RNW PLAN MANAGER PROGRAM BLOCK HAND RESTARTED

RNW Plan operation has been interrupted because of a restart of RNW Plan Manager program block hand process.

15376 NO REPLY TO RNW PLAN MANAGER PROGRAM BLOCK FROM HOKKUS

RNW Plan Manager program block has not received an answer from RNC SW configuration program block when trying to ask permission for the RNW Plan operation.

15377 RNW OBJECT (WBTS) RESERVED FOR OTHER FUNCTIONS (RNC OMU)

RNW object (WBTS) has been reserved for some other functions and therefore RAYBAN has failed in reserving it (or the whole RNW data-base) in time for plan operation.

15378 NO REPLY WHEN TRYING TO RESERVE RNW (OBJECT) FOR PLAN OPERATION

RNW Object Resource Manager (REUMAN, RNC OMU) has not answered to RNW Plan manager request to reserve WBTS or the whole RNW database for RNW Plan operation.

15379 XML PLAN FILE HANDLING SERVICE UNAVAILABLE

RNW Plan manager program block has failed in getting information on the RNW Plan Processing program block (PABROS) and therefore cannot continue RNW Plan operation.

Page 378: DX Error Messages

378 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15380 EFFECTIVE OPERATIONAL STATE IS NOT ENABLED FOR TP

The effective operational state for the external termination point is not enabled. This means that at least one of the objects (interface and tps) is not enabled. If it is a VP-level termination point, check that the inter-face and VPLtp are enabled. If it is a VC-level termination point, check that the interface and tps are enabled.

15381 RNW PLAN MANAGER PROGRAM BLOCK HAS FAILED IN RNW DATABASE RESERVING

RNW Object Resource Manager (REUMAN, RNC OMU) has declined twice RNW Plan manager program block request to reserve WBTS for RNW Plan operation.

15382 RNW PLAN MANAGER PROGRAM BLOCK HAS FAILED IN COPYING RNW DATABASE

RNW Plan manager program block has failed in copying RNW database files at the beginning of RNW Plan download or activation operation.

15383 MANDATORY PARAMETERS OF RNW OBJECT MISSING IN RNW PLAN

RNW Plan manager program block has discarded the handling of a RNW object received in RNW Plan because at least one of the manda-tory parameters is missing.

15384 ILLEGAL VALUES FOR RNW OBJECT PARAMETERS IN RNW PLAN

RNW Plan manager program block has discarded the handling of a RNW object received in RNW Plan because at least one of the param-eters has illegal value.

15385 RNW PLAN MANAGER PROGRAM BLOCK HAS FAILED IN RNW OBJECT (WBTS) RESERVING

RNW Object Resource Manager (REUMAN, RNC OMU) has declined twice RNW Plan manager program block request to reserve WBTS for RNW Plan operation.

15386 NO REPLY FROM RNW MANAGER PROGRAM BLOCK (RAKTOR, RNC OMU) TO RNW PLAN MANAGER

RNW Plan manager has not received an answer from RAKTOR when requesting RNW object updating to RNW database.

15387 ILLEGAL OPERATION FOR RNW OBJECT IN RNW PLAN

RNW Plan manager program block has discarded the operation directed to RNW object in RNW Plan.

15388 RNW DATABASE AND OBJECT RESERVING SERVICE UNAVAIL-ABLE (RNC OMU)

RNW Plan manager program block has failed in getting information on the RNW Object Resource Manager program block (REUMAN) and thus can not continue RNW Plan operation.

15389 RNW MANAGEMENT SERVICES UNAVAILABLE (RNC OMU)

Page 379: DX Error Messages

DN987378Issue 24-0

379

General Error Messages of System DX error messages

Id:0900d8058077e097

RNW Plan manager program block has failed in getting information on the RNW Manager program block (RAKTOR) and therefore can not continue RNW Plan operation.

15390 RNW PLAN OPERATION TASK ID REJECTED (RNC OMU)

The task identity received within RNW Plan operation request is unknown to RNW Plan manager program block.

15391 NO REPLY FROM RNW PLAN XML PROCESSING PROGRAM BLOCK (PABROS, RNC OMU)

RNW Plan manager program block has not received acknowledge message from PABROS when requesting RNW Plan file processing.

15392 WRONG RNW PLAN OPERATION FOR THIS TASK ID

RNW Plan Manager program block has interrupted RNW Plan opera-tion because the received task identity was originally recerved for another type of RNW Plan operation.

15393 CAN NOT ACTIVATE INCOMPLETELY DOWNLOADED RNW PLAN (RNC OMU)

Previous RNW Plan download operation has been interrupted (or no plan downloaded) and therefore RNW Plan manager program block has rejected the RNW Plan activation.

15394 CAN NOT ROLLBACK RNW PLAN FROM INCOMPLETELY STORED BACKUP COPY (RNC OMU)

Previous RNW Plan activation operation has been interrupted without successfull backup copying (or no plan activated) and therefore RNW Plan manager program block has rejected RNW Plan rollback.

15395 RNW PLAN INCONSISTENT (RNC OMU)

RNW Manager program block (RAKTOR, RNC OMU) has discovered that the data of the downloaded RNW Plan is inconsistent.

15396 MESSAGE FROM RNC OMS TO RNW PLAN MANAGER PROGRAM BLOCK IS MISSING

RNW Plan manager has not received an answer from RNC OMS in time and therefore RNW Plan operation is interrupted.

15397 RNW PLAN TASK ID REJECTED BECAUSE OF WRONG OPERA-TION STATE (RNC OMU)

RNW Plan manager program block has detected that the operation reserved within this task id is not waiting for starting (but already fin-ished) and therefore this RNW Plan operation is rejected.

15398 RNW PLAN MANAGER PROGRAM BLOCK HAS REJECTED THE RNW PLAN

RNW Plan manager program block has rejected the downloaded RNW Plan because of problems in object parameters.

15403 INTERNAL ERROR IN XML FILE PROCESSING PROGRAM BLOCK (PABROS, RNC OMU)

RNW plan operation has been interrupted because of internal error in PABROS.

Page 380: DX Error Messages

380 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15404 XML FILE PROCESSING PROGRAM BLOCK (PABROS, RNC OMU) BUSY

PABROS has rejected the service request because of an unfinished earlier XML file processing operation.

15405 FILE COMPRESSING SERVICES UNAVAILABLE (RNC OMU)

XML file processing program block (PABROS, RNC OMU) has failed in getting information on the File Compressor program block (HOKKUS).

15406 XML FILE PROCESSING PROGRAM BLOCK (PABROS, RNC OMU) HAS REJECTED COMPRESSED PLAN FILE

PABROS has not been able to accept the content of the compressed (GZIP) plan file. In case of RNW Plan, only one file with extension .XML is accepted insize the compressed file.

15407 PLAN FILE (DE)COMPRESSING REPLY MESSAGE MISSING

XML file processing program block (PABROS, RNC OMU) has not received acknowledge message from File Compressor program block (FCMPRS) after requesting decompression (plan download) or com-pression (configuration upload).

15408 COMPRESSED PLAN FILE INQUIRY FAILS

XML file processing program block (PABROS, RNC OMU) has failed in getting information on the content of the compressed plan file.

15409 ILLEGAL OPERATION FOR RNC OBJECT IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has rejected the operation directed to RNC object in RNW Plan.

15410 UNKNOWN ELEMENT IN XML PLAN FILE

The XML element detected from plan file by XML file processing program block PABROS, is either in wrong context or totally unknown.

15411 WRONG OBJECT ORDER IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has rejected the RNW Plan file because of wrong order of RNW objects.

15412 UNKNOWN PARAMETER FOR RNC IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown RNC object parameter (or incorrecly placed) in the RNW Plan file.

15413 UNKNOWN PARAMETER FOR WBTS IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown WBTS object parameter (or incorrecly placed) in the RNW Plan file.

15414 UNKNOWN PARAMETER FOR WCEL IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown WCEL object parameter (or incorrecly placed) in the RNW Plan file.

15415 UNKNOWN PARAMETER FOR ADJS IN RNW PLAN

Page 381: DX Error Messages

DN987378Issue 24-0

381

General Error Messages of System DX error messages

Id:0900d8058077e097

XML file processing program block (PABROS, RNC OMU) has detected an unknown ADJS object parameter (or incorrecly placed) in the RNW Plan file.

15416 UNKNOWN PARAMETER FOR HOPS IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown HOPS object parameter (or incorrecly placed) in the RNW Plan file.

15417 UNKNOWN PARAMETER FOR FMCS IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown FMCS object parameter (or incorrecly placed) in the RNW Plan file.

15418 RNW PLAN HEADER INFORMATION NOT FOUND

XML file processing program block (PABROS, RNC OMU) can not find header information from the RNW Plan file.

15419 UNACCEPTED ROOT ELEMENT IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has rejected the RNW Plan file because of wrong root element.

15420 REJECTED VALUE ELEMENT FOR PARAMETER IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has rejected parameter value element in RNW Plan file.

15421 XML FILE PROCESSING INTERRUPTED BY RNW PLAN MANAGER PROGRAM BLOCK

XML file processing program block (PABROS, RNC OMU) has received a request from RNW Plan manager program block to interrupt XML file processing.

15422 TOO MANY ITEMS IN IUR LIST

XML file processing program block (PABROS, RNC OMU) has found too many iur_list items from the RNW Plan file.

15423 TOO MANY ITEMS IN IU LIST

XML file processing program block (PABROS, RNC OMU) has found too many iu_list items from the RNW Plan file.

15424 INTERNAL XML REFERENCE (SCHEMA) FILE NOT FOUND

XML file processing program block (PABROS, RNC OMU) can not find the internal XML schema file from RNC OMU disk.

15425 INVALID CONTENT IN INTERNAL XML REFERENCE (SCHEMA) FILE

XML file processing program block (PABROS, RNC OMU) has detected errorneous data from the internal XML schema file.

15426 RNW OBJECT ID VALUE REJECTED IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has rejected value of RNW object identity attribute.

15427 RNW OBJECT ID ATTRIBUTE NOT FOUND IN RNW PLAN

Page 382: DX Error Messages

382 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

XML file processing program block (PABROS, RNC OMU) has not found the identity attribute of a RNW object.

15428 MML LOG TRANSFER FAILED

Network Element Backup Server is not able to transfer MML command log from HLR or between servers.

15429 SD THRESHOLD IS BIGGER THAN SF THRESHOLD

SD threshold is bigger than SF threshold.

15430 ILLEGAL SDH VC MAPPING FOR THIS UNIT TYPE

Illegal SDH VC mapping for this unit type. Legal VC mapping values: STM-0 (NIS0) VC-3 mapping STM-1 (NIS1) VC-3 or VC-4 mapping

15431 SDH VC PATH DOES NOT EXIST

The given SDH VC path does not exist.

15433 WCELS UARFCN + DL_PRI_SCR_CODE PAIR MUST BE UNIQUE UNDER WBTS

UARFCN (UTRAN Absolute Radio Frequency Number) and Downlink Primary Scrambling Code must together be unique under WCELs parent WBTS.

15434 CAC MESSAGE TIME OUT

Connection Admission Control (CAC) did not receive acknowledgement message from the service provider program.

15435 MIPC FUNCTION PROVIDED BY CHORUSOS API FAILED

MIPC function provided by ChorusOs API returns an error code.

15436 OPERATION DENIED IN SIGNALLING LINK OR ROUTE SET PARAMETER SET

Requested operation is defined to be denied in signalling link parameter set or signalling route set parameter set. Use NOI or NNI commands to check parameter set values and modify them if necessary.

15437 CANNOT REMOVE THE HOME DXT OF AN ORGANISATION BLOCK

Cannot remove the dxt because it is the home of an organisation block.

15438 CANNOT REMOVE THE HOME DXT OF AN ORGANISATION BLOCK OF SUBSCRIBERS

Cannot remove the dxt because it is the home of an organisation block of subscribers.

15439 CANNOT REMOVE THE DXT, IT HAS NEIGHBOUR CELL(S)

Cannot remove the dxt because it has neighbour cell(s).

15440 CANNOT REMOVE THE DXT, IT IS THE GATEWAY OF AN IP-SUBNET

Cannot remove the dxt because it is the gateway of an IP-subnet.

15441 CANNOT REMOVE OWN DXT BEFORE OTHER DXTS ARE REMOVED

Cannot remove the dxt before all other dxts are removed.

Page 383: DX Error Messages

DN987378Issue 24-0

383

General Error Messages of System DX error messages

Id:0900d8058077e097

15442 CANNOT REMOVE THE DXT, IT HAS LA ID RANGE(S)

Cannot remove the dxt because it has location area identifier(s).

15443 TXRX LOOP TEST RESULTS DO NOT EXIST

There is not any txrx loop test results in TXRFIL file. Run txrx loop test first.

15444 DATABASE DUMP IS TERMINATED DUE TO OVERLOAD

The dump in progress was terminated by database system due to excessive transaction load. The dumping is retried later automatically.

15445 REQUESTED TASK WAS COMPLETED ONLY PARTIALLY

The requested task was completed only partially.

15446 THE TP REMAINED RESERVED, REMOVE THE USAGE USING COMMAND LCY

Although the termination point is not in use, there is a usage noted. This happened due to problems in freeing the reserved termination point. You should manually free this termination point using the command LCY.

15447 THE SYSTEM CANNOT CALCULATE THE CDVT, ENTER A VALUE

The system internal floating point calculation is not accessible, there-fore CDVTs cannot be calculated. You can repeat the command entering the CDVT values yourself.

15448 TOO MANY WARM UP REQUESTS

There is already an active warm up request for given object.

15449 THIS DXT IS GROUP HLR

Such operation is tried that should not be done in GHLR.

15450 GIVEN FLEET DOMAIN IDENTIFIER IS ALREADY DEFINED IN THE DATABASE

Given Fleet Domain Identifier is already defined in the database.

15451 THIS EXCHANGE IS NOT THE HOME DXT FOR THE GIVEN FLEET DOMAIN IDENTIFIER

This exchange is not the home DXT for the given Fleet Domain Identi-fier.

15452 THE MAXIMUM NUMBER OF FLEET DOMAINS WAS EXCEEDED

The maximum number of Fleet Domains was exceeded.

15453 GIVEN FLEET DOMAIN IDENTIFIER IS NOT DEFINED IN THE DATABASE

Given Fleet Domain Identifier is not defined in the database.

15454 AT LEAST ONE FLEET SPECIFIC SHORT NUMBER DEFINED FOR FLEET DOMAIN

At least one Fleet Specific Short Number (FSSN) defined for Fleet Domain.

15455 UNKNOWN CLIENT APPLICATION

The requested client application does not exist in the database.

Page 384: DX Error Messages

384 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15456 UNKNOWN GROUP OVERLAY

The requested group overlay does not exist in the database.

15457 THE NEW APN COULD NOT BE ADDED BECAUSE THE APN NI EXISTS IN THE DATABASE

The apn ni exists in the database. All apn network identifiers must be unique, so it is not possible to add the apn to the database.

15458 THE APN POOL IS NOT ASSIGNED TO THE ORGANISATION BLOCK

The apn pool is not assigned to the organisation, so it is not possible to deassign it.

15459 THE APN IS NOT IN THE APN POOL

The apn is not removed from the apn pool, because it is not in the pool.

15460 THE APN POOL CAN NOT BE DELETED BECAUSE IT CONTAINS APNS

The apn pool is not deleted because it contains apns. All apn pools must be empty before they are deleted.

15461 THERE ARE NO APN POOLS IN THE SYSTEM

There are currently no apn pools in the system.

15462 CONNECTION BETWEEN SYSTEM-CORE -UNITS

Connection between system-core -units(SYM,CACU/RSMU,SYM-MXU) cannot be modified or deleted.

15463 GIVEN COMMAND REJECTED TO THIS CHILD UNIT

User command is not allowed to given hierarchical functional unit, because the command affects some other unit in hierarchy. User should give the command to the parent unit instead of the child unit.

15464 READING FROM OP2FIL FILE FAILED

Reading from OAM parameter file (OP2FIL) failed.

15465 WRITING TO OP2FIL FILE FAILED

Writing to OAM parameter file (OP2FIL) failed.

15466 THE ATTACHED MOBILE ALLOCATION LIST IS INVALID FOR THE TRX FREQUENCY

For RF hopping BTS the attached Mobile Allocation Frequency List and Underlay Mobile Allocation Frequency List has to match the frequency range (P-GSM/E-GSM) of the TRX. Detach the MA list/underlay MA list.

15467 FUNCTIONAL UNIT WHICH BELONGS TO SYSTEM-CORE

Functional unit which belongs to system-core cannot be deleted from system.

15468 SDH PROTECTION GROUP IDENTIFIER EXISTS

SDH protection group identifier is already in use. Cannot create protec-tion by using this group identifier. Also some SDH level configurations are not allowed if protection group is created.

15469 ILLEGAL SDH PROTECTION GROUP IDENTIFIER

Page 385: DX Error Messages

DN987378Issue 24-0

385

General Error Messages of System DX error messages

Id:0900d8058077e097

Illegal protection group identifier. Protection group does not exists.

15470 OPERATION FAILED AT TBS

Activation or execution of requested operation failed at the base station.

15471 RL SYNCHRONISATION LOST

WBTS has lost synchronisation on UL radio link.

15472 WBTS HARDWARE OVERLOAD

WBTS rejects the request because of hardware overload.

15473 O&M INTERVENTION

WBTS rejects the request because of O&M has blocked the needed resources.

15474 CELL RESTART IS NOT ALLOWED IN WBTS

WBTS rejects the request because of cell restart is not allowed.

15475 SIGNALLING BEARER OVERLOAD

WBTS rejects the request because of signalling bearer overload.

15476 UNSPECIFIED NORMAL EVENT

WBTS rejects the request because of normal unspecified event.

15477 EQUIPMENT FAILURE

WBTS rejects the request because of equipment failure.

15478 UNSPECIFIED CELL

WBTS rejects the request because the target cell has no configuration in WBTS.

15479 HARDWARE RESOURCES NOT AVAILABLE

WBTS rejects the request because of the HW resources are not avail-able.

15480 NO RESOURCES IN WBTS

WBTS rejects the request because of the WBTS resource manager considers the resources to be insufficient to fulfill the request.

15481 UNSPECIFIED RESOURCE SHORTAGE

WBTS rejects the request because of the needed resources are for unknown reason unavailable.

15482 WBTS CAPABILITY FAILURE

WBTS rejects the request because of the requested service has not been implemented.

15483 NO CAPABILITY TO COMBINE INDICATED CELLS

WBTS rejects the request because the BTS has no capacity to combine the requested cells.

15484 PARALLEL TRANSACTIONS NOT SUPPORTED

WBTS rejects the request because of parallel transactions are not sup-ported.

15485 SERVICE OR OPTION NOT AVAILABLE OR NOT IMPLEMENTED

Page 386: DX Error Messages

386 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

WBTS rejects the request because the service or option is unavailable or not implemented.

15486 TRANSFER SYNTAX ERROR

WBTS rejects the request because of transfer syntax error. See J2rib340.doc - Iub interface specification.

15487 ABSTRACT SYNTAX ERROR WITH REJECT

WBTS rejects the request because of abstract syntax error. See J2rib340.doc - Iub interface specification.

15488 NOTIFICATION OF ABSTRACT SYNTAX ERROR

WBTS notifies of an abstract syntax error. WBTS attempts to fullfill the request. See J2rib340.doc - Iub interface specification.

15489 ABSTRACT SYNTAX ERROR - FALSELY CONSTRUCTED MESSAGE

WBTS rejects the request because the received messag contained IEs or IE groups in wrong order or with too many occurrences.

15490 SEMANTIC ERROR

WBTS rejects the request because of semantic error. See J2rib340.doc - Iub interface specification.

15491 MESSAGE NOT COMPATIBLE WITH RECEIVER STATE

WBTS rejects the request because of the message is not compatible with the receiver state.

15492 ALREADY ACTIVATED OR ALLOCATED

WBTS rejects the request because the requested resource (channel or cell) has been already allocated or activated.

15493 NOT ALLOCATED OR ACTIVATED

WBTS rejects the request because the resource(s) (channel or cell) needed for the operation has not been allocated or activated.

15494 PARAMETER OUT OF RANGE

WBTS rejects the request because at least one of the parameters in the incoming message was out of range.

15495 INVALID COMPRESSED MODE SETTINGS

WBTS rejects the request because the compressed mode settings were considered as invalid.

15496 PARALLEL TRANSACTIONS NOT ALLOWED

WBTS rejects the request because parallel transactions are not allowed for this or the still ongoing procedure.

15497 BCCH SCHEDULING ERROR

WBTS rejects the request because of scheduling error in broadcast schedule for system information.

15498 RECONFIGURATION CFN NOT ELAPSED

WBTS rejects the request because a COMMIT message was received previously, but the concerning CFN has not yet elapsed.

Page 387: DX Error Messages

DN987378Issue 24-0

387

General Error Messages of System DX error messages

Id:0900d8058077e097

15499 UNSPECIFIED PROTOCOL ERROR

WBTS rejects the request because of unspecified protocol error. This means that the error was protocol related, but no specific protocol error cause was valid.

15500 CELL RESOURCE RESERVATION FAILED

The cell resource reservation failed in SPRM when creating the first common transport channel.

15501 RACH TRANSPORT ADDITION FAILED

NMR transport resource addition failed when reserving the AAL2 related DSP and/or PowerPC resources for RACH.

15502 FACH/PCH TRANSPORT ADD FAILED

NMR transport resource addition failed when reserving the AAL2 related DSP and/or PowerPC resources for FACH and PCH.

15503 MAC-C RACH CONFIGURATION FAILED

MAC-c RACH creation/reconfiguration failed.

15504 MAC-C FACH/PCH CONFIGURATION FAILED

MAC-c FACH and/or PCH creation/reconfiguration failed.

15505 FP RACH CONFIGURATION FAILED

Configuration of rnc_rab_common (frame protocol entity) for RACH failed.

15506 FP FACH CONFIGURATION FAILED

Configuration of rnc_rab_common (frame protocol entity) for FACH failed.

15507 FP PCH CONFIGURATION FAILED

Configuration of rnc_rab_common (frame protocol entity) for PCH failed.

15508 NO ANSWER FROM RRC-C

RRC-C has not answered common transport channel operation request sent by NBAP-C.

15509 NO ANSWER FROM RRC-S

RRC-S has not answered to system information request sent by NBAP-C.

15510 MAX NUMBER OF ATM CHANNELS ALREADY CREATED

Channel creation request is declined, because maximum number of ATM channels has already been reached

15511 VPLTP DOES NOT CONTAIN IPOA USAGE

The VPLtp does not contain IP over ATM usage.

15512 CREATING TRIAL CONFIGURATION UNIT LIST FAILED

Requested trial configuration unit list failed.

15513 CANCELLING TRIAL CONFIGURATION FAILED

Cancelling division of network element to two slices failed.

15514 CREATING REQUESTED TRIAL CONFIGURATION FAILED

Page 388: DX Error Messages

388 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Creating requested unit configuration to TRIAL slice failed.

15515 MOVING UNIT BETWEEN TRIAL SLICES FAILED

Moving unit from TRIAL slice to another failed.

15516 CUTOVER OPERATION FAILED

Performing cutover operation in TRIAL configuration failed.

15517 COMPLETING TRIAL CONFIGURATION FAILED

Completing the TRIAL configuration failed.

15518 CREATING TRIAL CONFIGURATION FAILED

Creating TRIAL configuration failed.

15519 TIME FOR WAITING RESPONSE FROM RC3PRB IS UP

A timer set for waiting a response from rc3 process has expired and no response has been received.

15520 TIME FOR WAITING RESPONSE FROM IUVPRB IS UP

A timer set for waiting a response from IUV process has expired and no response has been received.

15521 TIME FOR WAITING RESPONSE FROM IURPRB IS UP

A timer set for waiting a response from IUR process has expired and no response has been received.

15522 INVALID AMR HR CODEC MODE SET

The AMR HR codec mode set cannot contain the codec mode 7.40 kbit/s alone. At least one other codec mode must be included. The reason comes from the GSM specification 08.61 In-band control of remote transcoders and rate adaptors for half rate traffic channels. See the chapter Frame Synchronization / 8 kbit/s Submultiplexing / For Adaptive Multi-Rate Speech.

15523 INVALID AMR HR CODEC MODE SET WITH INITIAL CODEC MODE

If the initial codec mode is defined by the AMR HR start mode field, the 7.40 kbit/s mode cannot be used as the initial codec mode. The reason comes from the GSM specification 08.61 In-band control of remote transcoders and rate adaptors for half rate traffic channels. See the chapter Frame Synchronization / 8 kbit/s Submultiplexing / For Adaptive Multi-Rate Speech.

15524 NO RIGHTS TO REQUESTED SERVICE

The user does not have rights to use the requested service.

15525 MAXIMUM NUMBER OF TRXS IN PCU EXCEEDED

The maximum amount of GPRS enabled TRXs in one PCU has been exceeded. There is no room for any more GPRS enabled TRXs in this PCU.

15527 ADDING MEMBERS TO BACKGROUND GROUP NOT ALLOWED

Adding members to Background group (default scanning priority is CoU=7) is not allowed from infra to MS.

15528 SECURITY LOGIC FAULT

Security logic is faulty in SECMO-B plug-in unit.

Page 389: DX Error Messages

DN987378Issue 24-0

389

General Error Messages of System DX error messages

Id:0900d8058077e097

15529 NETWORK ELEMENT IS NOT SPLIT

This error code is given, when called Funlib library trial specific routines with slice identifier other_slice_c, original_c or trial_c, and the network element is not split.

15530 HOPI ID IS OUT OF RANGE

Interfrequency handover path parameter set id is out of range.

15531 HOPG ID IS OUT OF RANGE

GSM handover path parameter is out of range.

15532 FMCI ID IS OUT OF RANGE

Interfrequency measurement conrol parameter set id is out of range.

15533 FMCG ID IS OUT OF RANGE

GSM measurement conrol parameter set id is out of range.

15534 WBTS ID DOES NOT EXIST

The specified WBTS id does not exist in modifying.

15535 ADJI ID DOES NOT EXIST

In modifying ADJI parameters ADJI id is not created.

15536 ADJI ID HAS ALREADY BEEN CREATED

Interfrequency adjoining cell id has already been created.

15537 MAXIMUM NUMBER OF ADJI CELLS EXCEEDED

Maximum number of interfrequency neighbouring cells exceeded.

15538 HOPI HAS ALREADY BEEN CREATED

The specified interfrequency handover path has already been created.

15539 HOPI ID IS NOT CREATED

Interfrequency handover path is not created.

15540 FMCI HAS ALREADY BEEN CREATED

Interfrequency measurement control parameters has already been created.

15541 FMCI ID IS NOT CREATED

Interfrequency measurement control parameters is not created.

15542 ADJG ID HAS ALREADY BEEN CREATED.

Specified GSM neighbouring cell id has already been created.

15543 MAXIMUM NUMBER OF ADJG CELLS EXCEEDED

Maximum number of GSM neighbouring cell parameters exceeded.

15544 ADJG ID IS NOT CREATED

The GSM neighbouring cell parameter is not created.

15545 HOPG ID HAS ALREADY BEEN CREATED

GSM handover path parameter has already been created.

15546 HOPG ID IS NOT CREATED

GSM handover path parameter is not created.

15547 FMCG ID HAS ALREADY BEEN CREATED

Page 390: DX Error Messages

390 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

GSM measurement control parameters has alreay been created.

15548 FMCG ID IS NOT CREATED

GSM measurement control parameter set id is not created.

15549 OPERATION IS UNNEEDED, BECAUSE REQUESTED SITUATION ALREADY EXISTS

The operation was not performed because the existing situation is same as was requested.

15550 ENCODING OF LEG IS NOT AAL2

The encoding parameter of a leg is not AAL2.

15551 OWNER IDENTIFIER OF LEG HAS BEEN EXCEEDED

The owner identifier of the leg is either too big or too small.

15552 LEG HAS OAM FAILURE (F5-LEVEL)

The N_CID connection which is used for the new leg, has a F5-level OAM failure.

15553 INTERNAL N_CID TP ALREADY EXISTS

The N_CID creation has failed because the internal N_CID termination point already exists in LDFILE.

15554 RESOURCE UNIT IS NOT IN ACTIVE STATE

The resource unit (A2SP, DMPG, TPG or GTPU) is not in active state.

15555 ADJI ALREADY CREATED UNDER WCEL

An Inter Frequency Adjacency (ADJI) object with the given id entity is already created under given WCEL id in radio network database.

15556 ADJG ALREADY CREATED UNDER WCEL

An Inter Radio Access Technology Adjacency (ADJG) object with the given id entity is already created under given WCEL id in radio network database.

15557 PS OBJECT NOT FOUND

Packet Scheduler (PS) object not found in radio network database.

15558 HC OBJECT NOT FOUND

Handover Control (HC) object not found in radio network database.

15559 PC OBJECT NOT FOUND

Power Control (PC) object not found in radio network database.

15560 AC OBJECT NOT FOUND

Admission Control (AC) object not found in radio network database.

15561 LC OBJECT NOT FOUND

Load Control (LC) object not found in radio network database.

15562 RELATED OBJECT STILL EXISTS

There still exist objects related to the object to be deleted. Relations must be removed before deleting.

15563 MGW_ID OUT OF RANGE

MGW_ID out of range.

Page 391: DX Error Messages

DN987378Issue 24-0

391

General Error Messages of System DX error messages

Id:0900d8058077e097

15564 THE PCM OF THE CIRCUIT IS ALREADY ATTACHED TO SOME OTHER VMGW

The PCM of the circuit has already been attached to some other Virtual Media Gateway circuit group.

15565 CGR DELETION NOT ALLOWED, CGR IS ATTACHED TO VMGW

Circuit Group Deletion is not allowed because the CGR is attached to the VMGW.

15566 RGDPRB DID NOT ANSWER IN TIME FOR MGW_LIST_REQ_S

RGDPRB did not answer in time to mgw_req_s.

15567 MGW IS ALREADY REGISTERED

Media Gateway is already registered in the database.

15568 MGW IS NOT REGISTERED

MGW is not registered in the database.

15569 MGW REGISTRATION IS NOT ALLOWED

MGW registration is not allowed.

15570 MGW REGISTRATION IS ALLOWED

MGW registration is allowed.

15571 GROUP OVERLAY ALREADY EXISTS

Group overlay already exists in database.

15572 ILLEGAL ENCRYPTION METHOD

Encryption method is illegal.

15573 NO OPERATION, TARGET UNIT OR SYSTEM HAS FBAN STATUS

No operation, because target unit or system has full_rcvr_ban_c status.

15574 NO OPERATION, SYSTEM HAS FBAN STATUS

No operation, because system has full_rcvr_ban status.

15575 HW XML FILE GENERATION FAILED

The generation of the HW XML file failed.

15576 NSEI ALREADY EXISTS

Negative response to NSEI creation request. User must identify another NSEI parameter.

15577 REQUESTED INDEX IS NOT A TERMINATION_ID

Requested index is not a termination_id.

15578 INDEX NOT IN USE

The index is not in use.

15579 PROTECTION GROUP OR IMA GROUP DOES NOT EXIST

The protection group or IMA group is not created. Group is missing from files.

15580 ET ALREADY BELONGS TO OTHER IMA GROUP.

The Exchange terminal already is belong to some IMA group.

15581 THE ET IS ALREADY CONNECTED TO OTHER PHYTTP

Page 392: DX Error Messages

392 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The exchange Terminal is already connected to some other Physical TTP.

15582 UNIT STATE MUST BE WO BECAUSE IT HAS SCTP ASSOCIA-TIONS

The working state of the unit has to be active (WO) because it has SCTP associations.

15583 UNIT STATE MUST BE SP BECAUSE IT HAS NO SCTP ASSOCIA-TIONS

The working state of the unit has to be passive (SP) because it has no SCTP associations.

15584 INTER SYSTEM HANDOVER OPTION IS NOT IN USE IN BSC

Inter-system handover option is not in use in the BSC.

15585 PACKING THE CAC UPDATE DATA FAILED

packing the CAC update data on the working side failed

15586 FILE LOADING FAILED

The error code is used when loading of a file fails.

15587 THE GIVEN FILE IS ALREADY LOADED

An attempt was made to load a file. This file already exists.

15588 THE GIVEN FILE IS BEING LOADED

An attempt has been made to load a file. This file is now being loaded.

15589 A FILE HAS LISTENERS

The file that was being loaded has listeners.

15590 HW XML FILE DELETION FAILED

The deletion of the HW XML file was not successful. The HW XML file contains the HW configuration in XML format.

15591 HW XML FILE STATE INQUIRY FAILED

The state inquiry of the HW configuration XML file was not successful. The HW configuration XML file contains the HW configuration in XML format.

15592 INQUIRY OF HW DATA FROM EEPROM FAILED

HW data that is stored to EEPROMs of HW object could not be retrieved.

15593 ILLEGAL SEARCH KEY USED IN HW DATA INQUIRY

The search key that was used to specify the scope of the HW data inquiry, was illegal. This means that the inquiry cannot be done using this search key because the search key does not specify the scope of the inquiry explicitely.

15594 HW OBJECT TYPE UNKNOWN

The type of HW object is unknown.

15595 CLIENT DID NOT SENT ANOTHER REQUEST IN TIME

Page 393: DX Error Messages

DN987378Issue 24-0

393

General Error Messages of System DX error messages

Id:0900d8058077e097

The client that used the HW data inquiry service did not send another request in specified time limits. Re-request is needed when there is more HW data messages to come.

15596 STATE CHANGE OF THE IP ROUTE IS NOT ALLOWED

State Changes of the IP route is not allowed.

15597 FAILURE IN MUTEX USAGE

failure in mutex usage

15598 IPC PORT CREATION FAILED IN CAC

IPC port creation failed in CAC

15599 IPC SEND FAILED IN CAC

IPC send failed in CAC

15600 IPC RECEIVE FAILED IN CAC

IPC receive failed in CAC

15601 ALL DATA FOR XML FILE COULD NOT BE READ

Some readings of HW configuration data failed i.e. the HW configura-tion XML file does not contain all equipment database, EEPROM or static data information. Anyway all the data that has been successfully read is valid in the file.

15602 LAST ALTERNATIVE OF DESTINATION

Error code tells that something wrong is tryed to be done to last alterna-tive of destination. For example it is tryed to be deleted.

15603 UNKNOWN PARAMETER FOR HOPI IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown HOPI object parameter (or incorrectly placed) in the RNW Plan file

15604 ANALYSIS OF FLEET DOMAIN HOME DXT FAILS

Analysis of fleet domain home DXT fails because analysis input data is not found, is barred out, is not available or is corrupted.

15605 OPERATION FAILS BECAUSE G4WIF IS IN USE

Operation fails because G4WIF is in use. G4WIF line is member of a group or work station user has taken G4WIF line into use.

15606 OBJECT ADMINISTRATIVE STATE CONFLICT

There is a conflict in the object administrative state between RNEUPD and CRMPRB.

15607 DRMPRB DOES NOT ANSWER

DRMPRB does not answer.

15608 TEBMAN DOES NOT ANSWER

TEBMAN does not answer.

15609 WRONG WORKSTATION USER LEVEL

WSU level is different than WS.

15610 UNSUPPORTED OBJECT VERSION IN DOWNLOADED RNW PLAN

Page 394: DX Error Messages

394 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The version information tail added to RNW object name (e.g. RNC_1) can not be found from the list of supported versions.

15611 MAXIMUM COUNT OF URA IDENTITIES EXCEEDED IN DOWN-LOADED RNW PLAN

The maximum count of ura identities has been exceeded in the down-loaded RNW plan.

15612 LB INTERFACE IS NOT IN USE IN THE BSC

The purpose of the LB interface is to connect an external SMLC to a BSC. When this option is disabled the LB interface is not in use and an internal SMLC will be used.

15613 INVALID VALUE IN EC/NO PARAMETER

UTRAN NCELL SIGNAL LEVEL MEASUREMENT has received an invalid EC/NO -parameter value via NetAct and a fail constant is mapped from PUMPRB and the measurement is not turned on.

15614 DSP CODE LOADING NOT SUCCESFULL

This error code denotes the situation where the desired DSP code was not succesfully loaded

15615 LB PLUS OPTION IS NOT IN USE

This controls the Lb interface access to RNW database. If PBS_USAGE is on the RNW DB is allowed, but when PBS_USAGE is off, LB_PLUS determines whether RNW DB access is allowed or not.

15616 WRONG NSE TYPE IS TRIED TO BE MANAGED

When trying to manage an IP NS-VC with FR message or vice versa this error is returned.

15617 UNKNOWN PARAMETER FOR HOPG IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown HOPG object parameter (or incorrectly placed) in the RNW Plan file

15618 VIRTUAL PCM LINE NOT RESERVED

This is the common error code when reserving virtual PCM lines from PCMCON file.

15619 NO FREE INTERNAL PCMCON INDEX

Given PCM line can not be connected because there is no free internal index for given signalling unit. Internal index is used by file distributor. Indexes are stored to INFO_2 field in PCMCON.

15620 THE OPERATIONS IS PROCEEDING NORMALLY, BUT NOT YET READY.

The requested operation is proceeding normally, but it not yet ready. A second acknowledgement message will be sent after a while.

15621 CREATION OF SUBNET CONNECTION FAILED

The creation of subnet connection failed in MXU/NIS1-cluster.

15622 TP TO TMP CONVERSION FOR PQSAR FAILED

Page 395: DX Error Messages

DN987378Issue 24-0

395

General Error Messages of System DX error messages

Id:0900d8058077e097

Conversion of traffic parameters to traffic management parameters for PQSAR failed.

15623 TP TO TMP CONVERSION FOR MSSAR FAILED

Conversion of traffic parameters to traffic management parameters for MSSAR failed.

15624 PDCU DOES NOT HAVE AN IP ADDRESS ALLOCATED

PDCU has to have an IP address allocated before the subnet can be created.

15625 INVALID CHANNEL PRIORITY

Priority in channel reservation is invalid.

15626 INCORRECT TERMINATION_ID

Termination_id not defined

15627 NO MORE ROOM FOR N_CID OR 1_CID CONNECTION IN A2SP UNIT

The A2SP-unit, which is used for leg creation, is full: there is no more room for the N_CID or 1_CID connection.

15628 PARSE ERROR IN FILE

An error occured while parsing a file.

15629 ERROR IN MEGLIB

Meglib returned error status.

15630 H248 CONNECTION DOES NOT EXIST

H248 connection to MGW does not exist.

15631 H248 TIMER EXPIRED

H248 timer expired while waiting answer to command.

15632 LIST NOT FOUND

Received list did not contain any elements. It was empty.

15633 SOURCE AND TARGET WCELS MUST HAVE DIFFERENT FREQS IN ADJI (INTER-FREQ ADJ)

Frequency (uarfcn) of target WCEL is the same as frequency of source WCEL, so they cannot be defined as inter-freq neighbours (ADJI).

15634 TERMINATION POINT IS NOT AN ENDPOINT

The operation could not be performed because there is no endpoint related to the specified Termination Point.

15635 AAL2 STATIC TABLES INITIALISATION UNFINISHED

AAL2 static tables initialisation not finished yet. Wait a few seconds and try again.

15636 ATM CAC UNIT STATE NOT WORKING EXECUTING

BRTSEB cannot accomplish the requested task because the unit state is not working executing. This may concern MXU, NIS or some tributary unit.

15637 CELL ALREADY HAS ADJACENT UTRAN CELL WITH THE SAME CELL INDEX VALUE

Page 396: DX Error Messages

396 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The cell index is already in use in another adjacent UTRAN cell of the cell. It is not allowed to create several adjacent UTRAN cells using the same cell index value for the serving GSM cell.

15638 ADJACENT UTRAN CELL WAS NOT FOUND IN RNW DATABASE

The Adjacent UTRAN Cell has not been created into the RNW data-base.

15639 MESSAGING CLUSTER CENTER UNIT UNREACHABLE

Message cannot be sent, or messaging connection cannot be estab-lished because the center nodes of the messaging cluster are out of use.

15640 INDEX IN USE

Index in use

15641 GPRS IS DISABLED IN ALL THE TRXS OF THE CELL

The GPRS is disabled (GTRX=N) for all the TRXs in the cell. You must enable GPRS also for the TRXs.

15642 MEDIA GATEWAY NAME DOES NOT EXIST

The Name of the Media Gateway does not exist.

15643 INQUIRED UNIT IS NOT FOUND

Inquired unit is not found

15644 PRIORITY DOES NOT EXIST

A specified priority in an IWF list does not exist.

15645 PRIORITY ALREADY EXISTS

The priority specified already exists.

15646 VMGW NON-EXISTENT

VMGW does not exist.

15647 AMBIGUOUS COMBINATION OF VMGW NAME/ID

Ambiguous combination of VMGW ID and name.

15648 MAXIMUM NUMBER OF VMGW CONFIGURED FOR THIS ISU

Maximum number of VMGW has been configured for a given ISU.

15649 CELL PARAMETERS NOT ALLOWED FOR SLAVE BTS

This error code is used if cell parameters are tried to use for slave BTS.

15650 MISSING OBLIGATORY SEGMENT PARAMETERS FOR MASTER BTS

This error code is used if there are missing obligatory segment param-eters for master BTS.

15651 ROAMING SUBSCRIBER GROUP TYPE NOT FOUND

Given type does not exist in subscriber group files in GPDATA.

15652 ACCESS LIST NOT FOUND

Record of given subscriber group does not exist in GPDATA access list files.

15653 ACCESS LIST ALREADY EXISTS

Page 397: DX Error Messages

DN987378Issue 24-0

397

General Error Messages of System DX error messages

Id:0900d8058077e097

Given access list already exists in GPDATA access list files.

15654 SUBSCRIBER GROUP NOT FOUND

The given subscriber group was not found in the Subscriber group files in GPDATA.

15655 SUBSCRIBER GROUP EXISTS ALREADY

The given subscriber group exists already in the subscriber group files in GPDATA.

15656 PRIMARY CHANNEL DOES NOT EXIST

This error code is used if user tries to create secondary channel and primary channel does not exist.

15657 SECONDARY CHANNEL ALREADY EXISTS

This error code is used if a user tries to delete a primary channel and a secondary channel does exist.

15658 TOPOLOGY DATABASE ALREADY CONTAINS THIS UPD

The given UPD is already in the Topology DB.

15659 TOPOLOGY DATABASE DOES NOT CONTAIN THIS UPD

The given UPD is not in the Topology DB.

15660 TOPOLOGY DATABASE ALREADY CONTAINS THIS MGW

The given MGW is already in the Topology DB.

15661 TOPOLOGY DATABASE MGW COMPATIBILITY ERROR

The given MGW is not compatible to the UPD in the Topology DB.

15662 TOPOLOGY DATABASE MGW NOT PART OF UPD SPECIFIED

The given MGW is not part of the UPD specified in the Topology DB.

15663 MGW NOT IN TOPOLOGY DATABASE

The given MGW is not in the Topology DB.

15664 TOPOLOGY DATABASE CONNECTION ALREADY EXISTS

The given Connection is already in the Topology DB.

15665 TOPOLOGY DATABASE CONNECTION DOES NOT EXIST

The given connection is not in the Topology DB.

15666 MAXIMUM NUMBER OF ADJACENT UTRAN CELLS FOR ONE CELL EXCEEDED

One cell may have only a limited number of UTRAN neighbours. This number cannot be exceeded.

15667 CELL ALREADY HAS ADJACENT UTRAN CELL WITH THE NEW PLMN_RNC_CI VALUE

Cell already has such adjacent UTRAN cell which has the same PLMN, RNC identification and CI value as the new PLMN_RNC_CI value of the modified adjacent UTRAN cell.

15668 CELL ALREADY HAS ADJACENT WCDMA RAN CELL WITH SAME UARFCN AND SCRAMBLING CODE VALUE PAIR

The frequency and scrambling code combination is already in use in an adjacent WCDMA RAN cell of the cell. It is not allowed to create several

Page 398: DX Error Messages

398 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

adjacent WCDMA RAN cells using the same frequency (UARFCN) and scrambling code combination for the serving GSM cell.

15669 H248 MESSAGE PENDING

The H248 message sent to MGW is being processed.

15670 VCC BUNDLE ID ALREADY EXISTS

The given identifier is already assigned to a VCC Bundle.

15671 VCC BUNDLE ID DOES NOT EXIST

The given identifier is not assigned to any existing VCC bundle.

15672 TP NOT IN ANY VCC BUNDLE

The identified TP is not assigned to any existing VCC bundle.

15673 VCC BUNDLE NOT FOUND

No VCC bundles matching given search criteria exist.

15674 COMMON_BCCH_GSM800 OPTION IS NOT IN USE IN THE BSC

COMMON_BCCH_GSM800 option is not in use in the BSC.

15675 COMMON_BCCH_GSM1900 OPTION IS NOT IN USE IN THE BSC

COMMON_BCCH_GSM1900 option is not in use in the BSC.

15676 MESSAGE QUEUE OVERFLOWED

The message queue of a process has overflowed

15677 TOO SHORT MESSAGE QUEUE

A process has a too short message queue

15678 TOO MANY MESSAGES IN DATAGRAM

Datagram contains too many messages

15679 TP BELONGS TO VCC BUNDLE

The operation could not be performed because the identified TP belongs to a VCC bundle.

15680 TRIAL CONFIGURATION IS NOT CREATED

Error when executing of the trial operation: trial configuration is notcre-ated.

15681 THE CURRENT DEFAULT BUILD IS NOT BU OR IT IS NOT DEFAULT IN BOTH OMU UNITS

Illegal SW build configuration when creating of the trial configuration: The current default build is not BU or it is not default in both OMU units

15682 THE NEW DEFAULT SW BUILD FOR OMU IS NOT WITH NW OR FB STATUS

Illegal SW build configuration when creating of the trial configuration: The new default SW build for OMU is not with NW or FB status.

15683 THE DEFAULT BUILD IS SAME IN BOTH OMU UNITS

Illegal SW build configuration when deleting of the trial configuration: The default build is same in both OMU units.

15684 THE NEW DEFAULT SW BUILD FOR OMU IS NOT WITH NW, FB OR BU STATUS

Page 399: DX Error Messages

DN987378Issue 24-0

399

General Error Messages of System DX error messages

Id:0900d8058077e097

Illegal SW build configuration when deleting of the trial configuration: The new default SW build for OMU is not with NW, FB or BU status.

15685 THE NEW DEFAULT SW BUILD FOR OMU UNIT IS NOT DEFAULT IN OTHER OMU UNIT

Illegal SW build configuration when deleting of the trial configuration: The new default SW build for OMU unit is not default in other OMU unit.

15686 THE NW BUILD OR FB BUILD IS NOT DEFAULT BUILD IN EITHER OMU UNIT

Illegal SW build configuration during the trial configuration: The NW build or FB build is not default build in either OMU unit.

15687 THE BU BUILD IS NOT DEFAULT BUILD IN EITHER OMU UNIT

Illegal SW build configuration during the trial configuration: The BU build is not default build in either OMU unit.

15688 RESTARTING OF UNIT HAS BEEN SKIPPED BECAUSE BAN-STATUS

Restarting of unit has been skipped because BAN-status has been set for the unit. RBAN-status prevents system initiated restarts but allows restarts initiated by the operator. FBAN-status prevents all restarts.

15689 ERROR WHEN EXECUTING SUBSCRIPTION OF EVENT

Software configuration management operation is failed, because the event subscription is not successful.

15690 ASSOCIATION SET MODIFICATION NOT POSSIBLE

THE MODIFICATION OF THE ASSOCIATION SET IS DENIED BY S3CMAN.

15691 MAXIMUM COUNT OF CIRCUIT GROUPS TO MEDIA GATEWAY ID EXEEDED

There are too many circuit groups to the same Media Gateway Identi-fier.

15692 VCC RE-RESERVATION FAILED. ORIGINAL VCC IS STILL RESERVED.

VCC re-reservation failed. The original channel is still kept reserved.

15693 GSM800_1900 OPTION IS NOT IN USE IN BSC

GSM 800/1900 option is not in use in the BSC.

15694 GSM800_1800 OPTION IS NOT IN USE IN BSC

GSM 800/1800 option is not in use in the BSC.

15695 NO SUITABLE NSEI WHICH USES IP TRANSPORT FOUND IN THE RA

No suitable NSEI which uses IP transport was found in the routing area. Create one or do not specify the transport type of the NSEI.

15696 NO SUITABLE NSEI WHICH USES FR TRANSPORT FOUND IN THE RA

No suitable NSEI which uses FR transport was found in the routing area. Create one or do not specify the transport type of the NSEI.

Page 400: DX Error Messages

400 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15697 TETRA SYSTEM DOES NOT HAVE SUPPORT FOR THIS KIND OF HARDWARE

The source data contains information of hardware that is not supported in TETRA system.

15698 CALLER OF FUNCTION IS ILLEGAL PROCESS

Function call is not allowed by this process

15699 IN ASSOCIATION SET THE BITS OF IP ADDRESS IN NETMASK HAVE TO BE SAME IN ALL ASSOCIATIONS

The bits of IP address belonging to the netmask has to be same among all associations inside an association set.

15700 SLIPS ARE NOT MONITORED IN THIS UNIT

This error appears when trying to output slip measurements but current unit type does not supports slip measurement.

15701 GCRA I PARAMETER EXPONENT VALUE IS OUT OF RANGE IN VBR CHANNEL RESERVATION.

GCRA I parameter exponent value is out of range in VBR channel res-ervation.

15702 GCRA L PARAMETER IS TOO BIG IN VBR CHANNEL RESERVA-TION.

GCRA L parameter is too big in VBR channel reservation.

15703 GCRA L PARAMETER EXPONENT VALUE IS OUT OF RANGE IN VBR CHANNEL RESERVATION.

GCRA L parameter exponent value is out of range in VBR channel res-ervation.

15704 NO SUPPORT FOR TRANSCODER UNIT

1st generation Transcoder creation or usage is prohibited in BSC3i.

15705 AN ERROR OCCURED IN THE INITIALIZATION OF UBEDRV.

The initialization of the hand process failed. Either the hardware initial-ization, receiving of startup message or reserving a buffer failed.

15706 TRANSPORT TYPE PARAMETER GIVEN WITHOUT GPRS ENABLED PARAMETER

The parameter transport type (TRAT) can be given only when the parameter GPRS enabled (GENA) is set to value Y.

15707 UNKNOWN PARAMETER FOR FMCI IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown FMCI object parameter (or incorrectly placed) in the RNW plan file.

15708 UNKNOWN PARAMETER FOR FMCG IN RNW PLAN

XML file processing program block (PABROS,RNC OMU) has detected an unknown FMCG object parameter (or incorrectly placed) in the RNW plan file.

15709 CGR IS CURRENTLY ATTACHED TO ANOTHER VMGW

The given CGR is already attached to another VMGW.

Page 401: DX Error Messages

DN987378Issue 24-0

401

General Error Messages of System DX error messages

Id:0900d8058077e097

15710 MAXIMUM NUMBER OF VMGW UNITS HAVE BEEN CONFIGURED TO THIS ISU

Maximum number of VMGW units have been configured to this ISU.

15711 TTY/CTY CANNOT BE GIVEN WHEN REGISTRATION IS ALLOWED (REGA = 1)

TTY/CTY cannot be given when registration is allowed (REGA=1).

15712 FRAME RELAY BEARER CREATION OR DELETION NOT UPDATED TO PCU FRHTOR

Frame relay bearer creation or deletion not updated to PCU FRHTOR.

15713 RNW CONNECTION CONFIGURATION (COCO) MANAGEMENT SERVICE UNAVAILABLE (RNC OMU)

RNW Plan Manager program block has failed in getting information on the RNW Connection Configuration Manager program block (VEXELI) and thus cannot continue plan operation.

15714 NO REPLY FROM RNW CONNECTION CONFIGURATION MANAGER PROGRAM BLOCK

RNW Plan Manager has not received a reply from RNW Connection Configuration when requesting a COCO object update to RNW data-base.

15715 INCONSISTENT TRIAL INFORMATION IN BUFFER

This error code will be generated when information concerning build and unit data are not in predetermined order in buffer when doing tasks related to preparation phase in trial configuration handling.

15716 UNKNOWN PARAMETER FOR COCO IN RNW PLAN

XML file processing program block (PABROS,RNC OMU) has detected an unknown COCO object parameter (or incorrectly placed) in the RNW plan file.

15717 OAM SUPERVISION FOR THE UNDERLYING ATM INTERFACE IS NOT STARTED.

The error code is returned by OFXSEB when a requested action affects an ATM interface which is not undet OAM supervision.

15718 UNRESOLVABLE SYMBOL

Loader could not resolve a symbol in executable file.

15719 SERVICE PROVIDER FROM CO-SYSTEM (ORIGINAL OR TRIAL) HAS NOT RESPONDED WITHIN TIME LIMIT

The service user has made a service request to the co-system, but it has not responded within the time limit. The co-system is not capable to perform the requested service. Please, check the condition of the co-system.

15720 INCONSISTENT SLICE ID IN NE_SPLIT VARIABLE

NE_SPLIT system variable implicates that Network element is split but the slice_id does not have a valid value.

15721 FUNLIB SERVICE NOT READY TO BE PROVIDED

FUNLIB service was tried to use before it was initialized.

Page 402: DX Error Messages

402 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15722 BFA DID NOT RESPONSE WITHIN TIME LIMIT

BFA did not response within time limit, so the announcement is termi-nated.

15723 RM2 DID NOT RESPONSE WITHIN TIME LIMIT

RM2 did not response within time limit, so the announcement is termi-nated

15724 ANNOUNCEMENT ABORTED BY RM2

An announcement being played was aborted before the announcement playing was completed.

15725 THE IP VERSION IS NOT SUPPORTED

The IP version is not supported

15726 LOW LIMIT EMPTY

Low limit of the lan must be set

15727 THE LIMITS OF THE LAN ARE NOT VALID

The limits of the lan are not valid

15728 THE UPPER LIMIT OF THE LAN IS TOO BIG

The upper limit of the lan is too big

15729 THE NETMASK IS NOT VALID

The netmask is not valid. Valid values are between 4 to 30.

15730 LOW OR UPPER LIMIT OR GATEWAY ARE NOT IN SAME LAN

Low or upper limit or gateway addresses are not in same lan.

15731 DESTINATION OR GATEWAY ADDRESS INSIDE LAN

Destination or gateway address is inside LAN.

15732 OVERLAPPING ADDRESS WITH EXISTING LAN

Overlapping address with existing lan.

15733 LAN INCLUDES ALL ZEROS OR ALL ONES AS A HOST ADDRESS

Lan include all zeros or all ones as a host address

15734 SOME OF THE IP ADDRESSES ARE IN USE

Some of the IP addresses are in use

15735 AT LEAST ONE OF THE IP ADDRESSES ARE IN USE

At least one of the IP addresses are in use

15736 THIS LAN HAS PARAMETERS FOR STATIC ROUTE

Host creation failed because the LAN has been created with static route parameters (destination address, gateway address). Static route can be specified only to LANs for interface computers (IPETs).

15737 COULD NOT SET ACTOR KEY

Could not set caller identity in library invocation.

15738 THE INQUIRED TP DOES NOT EXIST IN HW.

The user has tried to access information about a termination point which is not configured in the hardware.

Page 403: DX Error Messages

DN987378Issue 24-0

403

General Error Messages of System DX error messages

Id:0900d8058077e097

15739 CHECKING WHETHER THE IP ADDRESS IS IN EXTERNAL USE FAILED

Checking whether the ip address is in external use failed. Check the ip addresses in external use with the following MML command: ZQRI

15740 PRIMESITE BTS WITH DF6 SW DOES NOT SUPPORT BB OR RF HOPPING.

PrimeSite BTS with DF6 software does not support baseband hopping and radio frequency hopping.

15741 INSITE BTS DOES NOT SUPPORT BB AND RF HOPPING

Insite BTS does not support baseband hopping and radio frequency hopping.

15742 PRAM ERROR IN APC

Device driver ICETEA has detected a PRAM error in APC hardware block.

15743 BRAM ERROR IN APC

Device driver ICETEA has detected a PRAM error in APC hardware block.

15744 CRAM ERROR IN APC

Device driver ICETEA has detected a CRAM error in APC hardware block.

15745 VCRAM ERROR IN APC

Device driver ICETEA has detected a VCRAM error in APC hardware block.

15746 NO RESET ACK MESSAGES RECEIVED FROM NODE

No reset ack messages received from HMS nodes.

15747 NO INIT ACK MESSAGES RECEIVED FROM NODE

No init_node_ack messages received from HMS nodes.

15748 NO CRC ACK MESSAGES RECEIVED FROM NODE

No CRC ack messages received from HMS nodes.

15749 NO ANSWERS TO VERSION REQUEST FROM NODES

No answers received to version request from HMS nodes.

15750 MAXIMUM AMOUNT OF TERMINATIONS EXCEEDED

If the maximum amount of terminations is exceeded, CILPRB replies to BC2PRB with error code error_t_context_term_full_ec.

15751 ANALYSIS STARTING TREE NUMBER VALUE NOT DEFINED

Analysis starting tree number value not defined. Check and update exchange parameter information.

15752 DATABASE REPLICATION GOING ON

The TDMS database was already in replica mode when replication was requested.

15753 DATABASE REPLICATION NOT ON

Page 404: DX Error Messages

404 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The TDMS database was not in replica mode when replication termina-tion request was sent.

15754 DATABASE IN REPLICA MODE

The TDMS database was in replica mode when a transaction request was sent. Normal transactions can not be executed in replica mode.

15755 NETWORK ELEMENT IS NOT READY FOR TRIAL OPERATION. CHECK CONFIGURATION.

The network element is not ready for trial operation. Unit(s) is(are) in wrong state or there are not enough unit for this trial operation.

15756 NETWORK ELEMENT IS SPLIT.

The network element is split, so a trial operation can not performin this configuration.

15757 FUNCTIONAL UNIT BELONGS TO SYSTEM-BASE

The functional unit belongs to the system-BASE.

15758 THIS UNIT CAN NOT BE MOVED BETWEEN SLICES

This unit can not be moved between slices, because it is non-splittable 2N unit.

15761 THERE ARE UNITS OUTSIDE SYSTEM-BASE

There are units outside system-BASE.

15762 SIGNALLING UNIT IS FULL, CALL PROCESSING CAPASITY OF UNIT(S) HAS BEEN USED

Signalling unit is full, call processing capacity of unit(s) has been used.

15763 BFA PID WAS NOT FOUND

The PID of BFA that was suppose to be sent in a sp_tr_return_para_t data type was not sent. Without PID VA2PRB cannot sent speech sample files to BFA.

15771 TRAP SENDING MODE IS OFF. LINK UP AND DOWN SET FAILED.

In case link up and down is wanted to set ON, the trap sending mode has to be ON.

15772 TRAP SENDING MODE IS OFF. AUTHENTICATION TRAP SET FAILED.

If it is required that authentication is ON, the trap sending mode has to be set ON as well.

15773 GIVEN IP ADDRESS AND NETMASK LENGTH DEFINE A IP NETWORK ADDRESS

The given IP address and net mask together define an IP address tha cannot be used as a host address.

15774 IP ADDRESSES WILL CROSS SUBETWORK BOUNDARY

The number of addresses cannot fit into the given subnetwork.

15775 NOT ENOUGH DATA

There is not enough data to perform the requested operation.

15776 LDAP NOT IN USE

Page 405: DX Error Messages

DN987378Issue 24-0

405

General Error Messages of System DX error messages

Id:0900d8058077e097

LDAPRB informs service requester that Directory Client is not in use.

15777 TRIAL CONFIGURATION MUST BE CANCELLED DUE TO CONTRA-DICTORY DATA

The information in NE_SPLIT system variable and of active SYM unit are contradictory. According to NE_SPLIT the network element should be sliced to two systems but there is no valid slice information in SCDFLE. Trial configuration must be cancelled.

15778 RNW CONNECTION CONFIGURATION (COCO) MANAGEMENT BUSY (RNC OMU)

RNW Plan Manager program block has detected that RNW Connection Configuration program block (VEXELI, RNC OMU) is busy (ongoing COCO operation) and therefore RNW plan operation can not be contin-ued.

15779 THE GIVEN FILE IS NOT LOADED

The given file is not loaded into memory.

15780 FUNCTIONAL UNIT NOT REMOVED DUE TO FOUND TSLS

System did not try to remove the given functional unit due to related PCM-TSLs. Remove PCM-TSL before aimed operation.

15781 UNIT ALREADY HAS PCM-TSL, FAILED TO REMOVE PCM-TSL, PCM-TSL NOT CREATED

Conflicting PCM-TSL definitions. See error log file for more information. Repeat the given command later.

15782 FAILED TO REMOVE PCM-TSL

Conflicting PCM-TSL definitions. See error log file for more information. To restore, re-create PCM-TSL and delete again.

15783 UNIT HAS PCM-TSL, FAILED TO REMOVE PCM-TSL, UNIT NOT REMOVED

Conflict between PCM-TSL- and D-channel definitions. Failed to remove the erroneous definitions. Repeat the given command later.

15784 CLIENT APPLICATION HAS SESSIONS. TDSC-UNIT NOT DELETED.

TDSC-unit not deleted due to on-going client sessions. Log off the ses-sion(s) and repeat the given command.

15785 GIVEN FNIM HAS CONFLICTING DEFINITIONS

Given FNIM has conflicting definitions, failed to remove the incorrect definitions, see error log file. To restore repeat given command.

15786 GENERAL UNIT NOT FOUND

Given general unit does not exist.

15787 IP SECURITY NOT ACTIVATED IN COMPUTER UNIT

The computer unit in question does not contain any IP Security config-urations.

15788 EGSM BCCH FREQUENCY AND PGSM FREQUENCY ARE NOT ALLOWED TO USE IN SAME SEGMENT

Page 406: DX Error Messages

406 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

BCCH frequency of EGSM band and frequency of PGSM band are not allowed to use in same SEGMENT (cell).

15789 A RELATION OR HASH CHAIN IS CYCLIC

A chain in a relation or hash directory contains cycle. The database is corrupted.

15790 A RELATION OR HASH CHAIN IS BROKEN

A chain of a hash directory or a relation is broken. The database is cor-rupted.

15791 SWMI DEFINITION NOT FOUND

Given SwMI definition was not found in the database.

15792 EPLMN RECORD ALREADY EXISTS IN THE LIST

Duplicate records (MCC+MNC) cannot exist in the equivalent PLMN list.

15793 MAXIMUM OF 10 UNIQUE DEFAULT APNS CAN EXIST

Maximum of 10 unique default APNs can exist inside the database.

15794 INVALID AMR FR CODEC MODE SET

Error code for illegal amr fr codec mode set.

15795 MAXIMUM NUMBER OF ENDPOINTS IN ROUTE

Maximum number of endpoint configured in route.

15796 OAM SUPERVISION IS NOT ACTIVE

OAM supervision is not activated for the given ATM interface or ATM connection

15797 MAXIMUM NUMBER OF ADJIS INCLUDED IN BCCH INFOEX-CEEDED

Maximum number of ADJIs included in BBCH INFO exceeded.

15798 UBSLIB NOT INITIALIZED

UBSLIB library is not initialized.

15799 GIVEN SWMI DEFINITION IS ALREADY DEFINED

Given SwMI definition is already defined in the database.

15800 A MAXIMUM NUMBER OF SWMIS IS ALREADY DEFINED

A maximum number of SwMIs is already defined in the database.

15801 MIGRATION IS NOT ALLOWED

Subscriber is not allowed to migrate to this SwMI

15802 BCF HAS NO ATTACHMENT IN ACTIVE OR PASSIVE STATUS

No HW database is attached to active or passive status in this BCF.

15803 GENERAL LDAP SERVER ERROR

LDAP server has returned an error code when performing LDAP oper-ation.

15804 GENERAL LDAP API ERROR

LDAP API has returned an error code when performing LDAP opera-tion.

Page 407: DX Error Messages

DN987378Issue 24-0

407

General Error Messages of System DX error messages

Id:0900d8058077e097

15805 CHANGING GATEWAY TYPE IS NOT ALLOWED WHEN CONNEC-TION GROUP HAVE PCMS

Connection group have PCMs. These must be removed first in order to change the gateway type.

15806 ADDING A GIVEN TYPE PCM TO THIS CONNECTION GROUP IS NOT ALLOWED

It is not possible to add given type PCM to a connection group of this gateway type. Modify connection groups gateway type so that the PCM may be added.

15807 THE IDENTIFIER OF PLMN NOT MODIFIABLE

The identifier of PLMN is not modifiable.

15808 GIVEN FILTER VALUE IS ILLEGAL.

receive_oper_state_change_as service returns this error code for reg-isterations with illegal filter value.

15809 GIVEN PID IS ILLEGAL.

receive_oper_state_change_as service returns the error code for regis-terations with illegal PID value e.g. with any_c.

15810 MAXIMUM AMOUNT OF FILTERS ALREADY IN USE.

receive_oper_state_change_as service returns the error code for regis-teration with instace which has already maximum amount of filters in use.

15811 REGISTRATION FAILED.

receive_oper_state_change_as returns the error code when registera-tion or deregisteration has failed.

15812 RE-REGISTRATION EXECUTED SUCCESSFULLY.

receive_oper_state_change_as service returns the error code when client re-registers with PID and ORDER_NRO which already exist in the client "database"

15813 NOTHING TO BE DEREGISTERED.

receive_oper_state_change_as service returns the error code when it can not find the entry from the client "database" to be deregisetered.

15814 MAXIMUM NUMBER OF OAM CONTINUITY CHECKS FOR GIVEN INTERFACE HAS ALREADY BEEN ACTIVATED

Maximum number of OAM continuity checks for given ATM interface has already been activated

15815 TP IS NOT CONNECTION TERMINATION POINT.

oam_atm_continuity_check_as returns the error code when cc is requested for the tp which is intermediate point of connection.

15816 UNKNOWN PARAMETER FOR WSMLC IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown WSMLC object parameter (or incorrectly placed) in the RNW Plan file.

15817 UNKNOWN PARAMETER FOR WLCSE IN RNW PLAN

Page 408: DX Error Messages

408 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

XML file processing program block (PABROS, RNC OMU) has detected an unknown WLCSE object parameter (or incorrectly placed) in the RNW Plan file.

15818 COCO AAL2 ADDRESSES NOT UNIQUE

The AAL2 user plane link related numbering is not unique. Check the A2EA and AAL2 path id values from the COCO object because there is another COCO object using the same values.

15819 MAXIMUM AMOUNT OF COCO OBJECTS EXCEEDED

The COCO object creation is not possible because the maximum amount of COCO objects is already created to the system.

15820 ETHERNET START ERROR

The initial message exchange over the Ethernet has failed.

15821 ETHERNET SUPERVISION ERROR

The supervision of the Ethernet has failed.

15822 NO ETHERNET ERROR

The post office has been unable to discover the identity and MAC address of the Ethernet chip in the unit.

15823 NO OTHER ETHERNET ERROR

The post office has been unable to discover the identity and MAC address of the Ethernet chip in the other unit.

15824 NO ANSWER RECEIVED FROM PROCESS SA3 IN TIME

Timer for waiting an answer message from the SA3 process has expired without a response.

15825 RBROKE IS EXECUTING SAVED RELEASE REQUESTS

RBROKE has saved some release requests during a switchover or ALP-cluster warming. It is now executing these requests and cannot accept normal requests.

15826 ADMINISTRATIVE STATE OF RELATED SLAVE BCF IS INCORRECT

Related slave BCF is in incorrect administrative state for requested operation.

15827 SYNCH OF BCF CLOCK CHAIN IS ENABLED

Synch (SENA) of related clock chain is enabled. Synch enabled is a master clock BCF-specific parameter.

15828 TOO MANY BCFS DEFINED TO CLOCK CHAIN

Too many BCFs are defined to the clock chain.

15829 FTP FILE TRANSFER ERROR

FTP file transfer failed.

15830 BCF ALREADY DEFINED TO MASTER CLOCK BCF

Related BCF is already defined to master clock BCF in the radio network database.

15831 BCF ALREADY DEFINED TO INDEPENDENT BCF

Page 409: DX Error Messages

DN987378Issue 24-0

409

General Error Messages of System DX error messages

Id:0900d8058077e097

Related BCF is already defined to independent mode in radio network database.

15832 BCF ALREADY DEFINED TO SLAVE BCF

Related BCF is already defined to slave BCF in radio network database.

15833 BCF MUST BE DEFINED TO MASTER CLOCK BCF OR INDEPEN-DENT BCF

Related BCF must be defined to master clock BCF or independent BCF in radio network database.

15834 MASTER CLOCK BCF ID DOES NOT EXIST IN LMU AREA

Related master clock BCF does not exist in LMU area in radio network database.

15835 LMU AREA DOES NOT SUPPORT BSS SYNCHRONISATION

Master clock BCF related LMU area does not support synchronisation (Value of lmu usage parameter must be either both or synch).

15836 LMU FN OFFSET IS NOT IN USE

LMU area related lmu fn offset is not in use.

15837 SLAVE BCF SW DOES NOT SUPPORT SYNCHRONISATION

The slave BCF software level (as read from database) does not support the usage of the slave BCF for synchronisation.

15838 BCFS OF ALL BTSS IN SAME CELL (SEG) MUST BE DEFINED TO THE SAME CLOCK CHAIN

BCFs of all BTSs in same cell must be defined to the same clock chain in radio network database.

15839 TIMER FOR WAITING ANSWER TO BTS_CLOCK_REQ FROM BTS IS EXPIRED

Timer for waiting answers to BTS_CLOCK_REQ message from BTS is expired.

15840 SYNCHRONISATION INFORMATION NOT FOUND FROM RADIO NETWORK DATABASE

Independent BCF or clock chain BCFs related sychronisation informa-tion has not been found from radio network database.

15841 A SHAPED VPLTP CANNOT BE CROSS-CONNECTED

Cross connections on VP level must use non-shaped VPLtps. Delete this VPLtp and create an unshaped one instead.

15842 FIRST AND SECOND TP ARE IDENTICAL

A cross connection cannot be established, because the two ends are identical. Chose two individual terminations points as the ends of the cross connection.

15843 RLC TRANSMISSION BUFFER IS EMPTY

Indicates that the RLC transmission buffer is empty.

15844 GPRS ENABLED TRX OF EGPRS BTS NOT IN DYNAMIC ABIS POOL POOL

Page 410: DX Error Messages

410 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The GPRS enabled TRX (GTRX=Y) of an EGPRS enabled BTS (EGENA=Y) have to be attached to a Dynamic Abis Pool (DAP). ).

15845 ATM CONNECTION TERMINATION POINT CANNOT BE INSIDE A SEGMENT

ATM connection termination point cannot be inside a segment.

15846 EMT CONNECTION WAS SET DOWN

EMT connection was set to down state. Most probably reason for this is that switch over happened in the computer unit pair handling the EMT connection. Usually client can continue to use the same EMT connec-tion with EMT_RECONNECT message.

15847 MTU MODIFICATION IS FORBIDDEN

MTU ( Maximum Transfer Unit ) parameter modification is forbidden.

15848 THE VC LINK TERMINATION POINT HAS A TOO LARGE PCR FOR AN AAL2 ENDPOINT

The VCLtp has a too large PCR for AAL2 purposes. Define a smaller value using the command LCM.

15849 THERE ARE NOT UNITS TO BE MOVED

There are not units to be moved from system to system.

15850 CRYPTO CHIP NOT AVAILABLE IN OLD HW.

Crypto chip is not available because the HW is too old.

15851 UNKNOWN SPLIT STATE IN THE NE_SPLIT SYSTEM VARIABLE

There is unknown split state information in the NE_SPLIT system vari-able.

15852 WCEL IS BLOCKED BY THE WBTS

WCEL is blocked by WBTS.

15853 OAM CONTINUITY CHECK IS ALREADY ACTIVATED FOR GIVEN TP

OAM Continuity Check has already been activated for the given TP.

15854 OAM CONTINUITY CHECK IS ALREADY ACTIVATED WITH DIFFER-ENT OAM LEVEL FOR GIVEN TP

OAM Continuity Check is already activated with different OAM level for given TP.

15855 SPEECH LINE TESTS ARE DISABLED

Interexchange speech line tests are disabled.

15856 TOO MANY GPRS TCH TSLS IN RELATED NSEI

More GPRS or EGPRS capacity cannot be added to the related NSEI.

15857 TOO MANY EGPRS TCH TSLS IN RELATED NSEI

More EGPRS capacity cannot be added to the related NSEI.

15858 ALP CLUSTER OVERLOAD

The ALP cluster (MXU/NISx) is overloaded, and the creation operation is rejected.

15859 DEACTIVATION OF OAM SUPERVISION FAILED

Page 411: DX Error Messages

DN987378Issue 24-0

411

General Error Messages of System DX error messages

Id:0900d8058077e097

OAM supervision could not be stopped

15860 OPERATION CANNOT BE DONE FOR VPCTP

Operation cannot be done for VPCtp.

15861 PARAMETER CATEGORY NOT FOUND

Given parameter category does not exist in the Nokia TETRA system.

15862 SDH PATH PAYLOAD TYPE IS NOT CORRECT

SDH path payload type is wrong.

15863 MICROCODE NOT FOUND

The name of the microcode cannot be found in MICROCGX.XML.

15864 MICROCODE IS NOT NEEDED

There is no microcode for the given PIU. This is not an error situation.

15865 SYSTEM IMAGE AND MICROCODE ARE MISSING

Jupina did find neither the system image nor the microcode.

15866 VDS DEVICE CONTROL FILE CORRUPTED

VIDAST has detected that its transfer control file (TTTCOF) is cor-rupted. Timestamp(s) in the control file are not valid date(s). Most likely the VDS counterpart in the post-processing system has transferred an illegal TTTCOF to DX/IPA.

15867 CONNECTIONS OF WO AND SP UNITS ARE INCONSISTENT

States of AAL5 messaging connections of WO and SP units are incon-sistent. They have different numbers of connections in open state.

15868 MAC ADDRESS HAS BEEN OVERWRITTEN.

Mac address has been overwritten.

15869 MEASUREMENT BCCH ALLOCATION LIST ALREADY CREATED IN RNW DATABASE

Measurement BCCH allocation list already created in radio network database.

15870 MEASUREMENT BCCH ALLOCATION LIST OBJECT WAS NOT FOUND IN RNW DATABASE.

Measurement BCCH allocation list object was not found in radio network database.

15871 MEASUREMENT BCCH ALLOCATION FREQUENCY LIST ISFULL

No more frequencies can be added to the measurement BCCH alloca-tion frequency list.

15872 MEASUREMENT BCCH ALLOCATION FREQUENCY LIST IS IN USE.

Measurement BCCH allocation list is in use.

15873 TEST EQUIPMENT IS NOT ALLOWED TO EXIST IN SITE TYPE MODIFICATION

Test equipment is not allowed to exist during BTS site type mod-ification.

15874 INVALID MAXIMUM EXTENDED CELL RADIUS IN SITE TYPE MOD-IFICATION

Page 412: DX Error Messages

412 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The extended cell radius cannot be more than 35 km when the BTS site type is modified from Nokia 2nd generation BTS to Nokia UltraSite.

15875 OMUSIG CANNOT BE IN WO STATE IN SITE TYPE MODIFICATION.

The OMU link of the BCF cannot be in working state when the BTS site type is modified to Nokia UltraSite. Change the state of the OMU link.

15876 DFCA AND ANTENNA HOPPING CANNOT BE USED SIMULTANE-OUSLY IN A BTS

DFCA modes "DFCA hopping" or "BB hopping" cannot be used simul-taneously with Antenna Hopping in a BTS.

15877 ANTENNA HOPPING AND BB HOPPING CANNOT BE USEDSIMUL-TANEOUSLY IN A BTS

Antenna Hopping cannot be used simultaneously with BB hopping in a BTS on either regular or super layer (HOP=BB or UHOP=BB).

15878 ILLEGAL MOBILE ALLOCATION FREQUENCY LIST IDENTIFICA-TION

Illegal mobile allocation frequency list identification.

15879 FUNCTION NOT ALLOWED FOR A NON-DFCA MA LIST

Function not allowed for a non-DFCA MA-list.

15880 A FREQUENCY IS ON TWO DFCA MA LISTS

A frequency is on two DFCA MA-list.

15881 WRONG DFCA MA LIST STATE FOR THE OPERATION

Wrong DFCA MA list state for the operation.

15882 NO DFCA TRX DEFINED

In BB hopping DFCA mode at least one DFCA TRX is required before DFCA can be switched on.

15883 ONE ATTACHED DFCA MA LIST FOR CS USE REQUIRED FOR THE BTS

One attached DFCA MA-list for CS use is required for the BTS.

15884 WRONG NUMBER OF FREQUENCIES ON DFCA MA LIST

Wrong number of frequencies on DFCA MA-list.

15885 ATTEMPTED DFCA MODE NOT ALLOWED FOR THE SITE TYPE

Attempted DFCA mode not allowed for the site type.

15886 DFCA UNSYNCHRONIZED MODE MA LIST REQUIRED

In DFCA hopping and RF hopping DFCA modes a separate MA list for the unsynchronized operation is required.

15887 NUMBER OF ALLOWED DFCA MA LIST ATTACHMENTS EXCEEDED

The maximum number of DFCA MA lists that can be attached to a BTS is exceeded.

15888 SYNCHRONIZATION OF THE CHAIN IS NOT ENABLED

Using of DFCA requires that (LMU) synchronization of the chain is enabled.

Page 413: DX Error Messages

DN987378Issue 24-0

413

General Error Messages of System DX error messages

Id:0900d8058077e097

15889 CLOCK SOURCE OF THE CHAIN IS NOT LMU OR LMU-ABIS

Using of DFCA requires BSS synchronisation. Synchronisation source of the chain must be either LMU or LMU-ABIS.

15890 DFCA BCCH FREQUENCY LIST CANNOT BE ATTACHED TO ANY BTS.

DFCA BCCH frequency list cannot be attached to any BTS.

15891 DFCA WITH AUTOMATED PLANNING ENHANCEMENTS NOT SUP-PORTED

Dynamic Frequency and Channel Assignment cannot be used together with Automated Planning Enhancements in a BTS.

15892 SUPER REUSE TRX NOT ALLOWED WITHIN A DFCA BTS

Super reuse TRX not allowed within a DFCA BTS.

15893 SDCCH AND PS DATA CHANNELS ON DFCA TRX FEATURE NOT IN USE IN BSC

Licenced SDCCH and PS Data Channels on DFCA TRX feature is needed in BSC to use PS data on DFCA TRX

15894 E-TRX OR S-TRX NOT ALLOWED IN A DFCA BTS

E-TRX OR S-TRX NOT ALLOWED IN A DFCA BTS

15895 ADJI AND ITS SOURCE WCEL MUST HAVE DIFFERENT FREQS

ADJI and its source WCEL must have different freqs.

15896 IF RT FMCI IS GIVEN, ALSO NRT FMCI IS NEEDED

If RT FMCI is given, also NRT FMCI is needed.

15897 IF NRT FMCI IS GIVEN, ALSO RT FMCI IS NEEDED

IF NRT FMCI IS GIVEN, ALSO RT FMCI IS NEEDED.

15898 IF RT FMCG IS GIVEN, ALSO NRT FMCG IS NEEDED

IF RT FMCG IS GIVEN, ALSO NRT FMCG IS NEEDED.

15899 IF NRT FMCG IS GIVEN, ALSO RT FMCG IS NEEDED

IF NRT FMCG IS GIVEN, ALSO RT FMCG IS NEEDED.

15900 GIVEN VCI VALUE OUT OF RANGE IN IVBEER

Outward vci value is bigger than vci_bits in XML-file allows.

15901 ADDRESS CONVERSION FAILED IN IVBEER

For some reason address conversion failed in Ivbeer.

15902 WSMLC NOT FOUND

WSMLC object cannot be found from RNW database.

15903 WSMLC ALREADY CREATED

WSMLC object is already created in RNW database.

15904 WLCSE NOT FOUND

WLCSE not found from RNW database.

15905 WLCSE ALREADY CREATED

WLCSE is already created in RNW database.

Page 414: DX Error Messages

414 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15906 MEMORY AREA IN WHICH RECEIVING BUFFERS OF SIGNALLING TERMINALS ARE LOCATED IS FULL

There is not enough free memory space left in the common receive buffer area of the signalling terminals. The system cannot allocate RX buffers for all signalling terminals. The size of the receive buffer area must be enlarged.

15907 PARAMETER INTERDEPENDENCE ERROR

Parameter interdependence error.

15908 EMR SUPPORT OPTION IS NOT IN USE IN BSC

EMR (enhanced measurement report) support in BSC (base station controller) is used for reporting of the supporting mobile stations. When this option is disabled the EMR support in BSC is not in use.

15909 EOTD BR USAGE OPTION IS NOT IN USE IN BSC

Option enables the E-OTD (enhanced observed timing difference) broadcasting. When this option is disabled the EOTD BR usage is not in use.

15910 TOTAL FEP USAGE OPTION IS NOT IN USE IN BSC

Purpose of the Total FEP (frame erasure probability) is improving the accuracy of the information required building a frequency plan. When this option is disabled the Total FEP Usage is not in use.

15911 DFCA FEATURE IS NOT IN USE IN BSC

The purpose of the DFCA (dynamic frequency and channel allocation) is to offer a new channel assignment scheme. When this feature is disabled the DFCA is not in use.

15912 GPS BR USAGE OPTION IS NOT IN USE IN BSC

Option enables the GPS (global positioning system) data transfer and broadcasting. When this option is disabled the GPS BR usage is not in use.

15913 REMOTE TBS MMI CONNECTION DENIED BY TBS

Remote TBS MMI connection is denied by TBS.

15914 USPMAN WARMING IN PROGRESS

Uspman warms its own spare unit. During warming some operations are not allowed.

15915 USPMAN IS STARTING UP

During USPMAN start-up some operations are not allowed.

15916 DATABASE CONSISTENCY CHECK INTERRUPTED BY RNW PLAN MANAGER PROGRAM BLOCK

DATABASE CONSISTENCY CHECK INTERRUPTED BY RNW PLAN MANAGER PROGRAM BLOCK

15917 PPP INTERFACE IS NOT UPDATED TO HARDWARE

PPP interface is not updated to hardware

15918 ANTENNA HOPPING BTS HAS INCORRECT ADMINISTRATIVE STATE FOR REQUESTED TASK

Page 415: DX Error Messages

DN987378Issue 24-0

415

General Error Messages of System DX error messages

Id:0900d8058077e097

In TRX lock and TRX unlock BTS administrative state must be locked.

15919 ILLEGAL SUBSCRIBER CLASS

Used for return status with illegal subscriber class in dma_ack_s -message.

15920 ANTENNA HOPPING OPTION IS NOT IN USE IN BSC

Antenna hopping is an enhancement to RF (radio frequency) hopping. When this option is disabled, antenna hopping is not in use.

15921 PREEMPT OPTION IS NOT IN USE IN BSC

Preemption usage is not in use in BSC (base station controller).

15922 WPS OPTION IS NOT IN USE IN BSC

With WPS (wireless priority service) it is possible to prioritize traffic channels. When this option is disabled, WPS is not in use.

15923 TARGET CELL OF THE ADJACENCY IS NOT ALLOWED TO CHANGE IF TARGET CELL IS UNDER THE SAME RNC

Target cell of the adjacency is not allowed to change if target cell is under the same RNC.

15924 AMR HR FEATURE IS NOT IN USE IN BSC

AMR HR (adaptive multirate half rate) feature is not in use when this option is disabled.

15925 INTERFERING CELL CGI NOT UNIQUE WITHIN TRX

CGIs (Cell Global Identification) of interfering cells within one TRX (transceiver) must be unique.

15926 NO ANSWER RECEIVED FROM PROCESS RLA IN TIME

Timer for waiting an answer message from process RLA has expired, and no answer has been received.

15927 OAM CONTINUITY CHECK IS ALREADY DEACTIVATED FOR GIVEN TP

OAM Continuity Check has tried to deactivate for a TP which does not have any active CCs in the given direction.

15928 TRACE ADDITION UNSUCCESSFUL

The given SGSN trace could not be added in database.

15929 TRACE REMOVAL UNSUCCESSFUL

The given SGSN trace could not be removed from database.

15930 TRACE CANNOT BE INTERROGATED

The given SGSN trace information could not be interrogated.

15931 LIST OF TRACES CANNOT BE SHOWN

The list of SGSN traces could not be shown.

15932 PAPU OF SUBSCRIBER UNRESOLVED

The PAPU unit of the subscriber could not be resolved.

15933 PTMSI UNRESOLVED

The PTMSI of the subscriber could not be resolved.

Page 416: DX Error Messages

416 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

15934 BSC TRACE ACTIVATION UNSUCCESSFUL

Activation of BSC trace (via SGSN) was unsuccessful.

15935 BSC TRACE MODIFICATION UNSUCCESSFUL

Modification of BSC trace (via SGSN) was unsuccessful.

15936 BSC TRACE DEACTIVATION UNSUCCESSFUL

Deactivation of BSC trace (via SGSN) was unsuccessful.

15937 PENDING TRACE ACTIVATION UNSUCCESSFUL

The pending trace activation in SGSN was unsuccessful.

15938 BSC PENDING TRACE ACTIVATION UNSUCCESSFUL

The pending trace activation in BSC was unsuccessful.

15939 TRACE KEY UNRESOLVED

Identification by which the trace was set could not be resolved.

15940 TRACE DATABASE NOT UPDATED

Changes related to SGSN trace information could not be updated.

15941 CS CN NOT DEFINED FOR THE RNC

CS CN not defined for the RNC.

15942 PS CN NOT DEFINED FOR THE RNC

PS CN not defined for the RNC.

15943 UNIT WAS RESTARTED WHILE IT WAS ACTING AS CODE LOADING SOURCE

A unit was restarted while it was acting as code loading source.

15944 UNIT WAS RESTARTED WHILE IT WAS ACTING AS FILE LOADING SOURCE

A unit was restarted while it was acting as file loading source.

15945 OPERATION DENIED, SOME WCEL(S) CONNECTED TO CN (CORE NETWORK DEFINITION IN RNC)

Operation denied, because some WCEL(S) connected to Core Network defined in RNC. Same PLMN id and Core Network id defined for WCEL and Core Network.

15946 SAB PARAMETERS NOT DEFINED

SAB parameters not defined.

15947 SAC_B PARAMETER MUST BE UNIQUE IN RNC

SAC_B must be unique in RNC.

15948 UNKNOWN PARAMETER FOR ADJI IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown (or incorrectly placed) ADJI object parameter in the RNW Plan file.

15949 UNKNOWN PARAMETER FOR ADJG IN RNW PLAN

XML file processing program block (PABROS, RNC OMU) has detected an unknown (or incorrectly placed) ADJG object parameter in the RNW Plan file.

Page 417: DX Error Messages

DN987378Issue 24-0

417

General Error Messages of System DX error messages

Id:0900d8058077e097

15950 TWO IDENTICAL SPCS IN SPC LIST

Two identical Signaling Point Codes in Signaling Point Code list.

15951 DATA 144 OPTION IS NOT IN USE IN BSC

The option determines whether 14.4 kbit/s channel coding is used in the BSC or not.

15952 AUTOMATIC LOCKING OF RNW OBJECT NOT ALLOWED

RNW Manager Program Block (RAKTOR, RNC OMU) or RNW Connec-tion Configuration Manager Program Block (VEXELI, RNC OMU) has discovered that the permission for needed automatic RNW object locking is not given. The permission flag is stored within RNC data in RNW database.

15953 GPRS ENABLED BCCH TRX IS NOT EDGE CAPABLE

HW of GPRS Enabled BCCH TRX is not EGPRS-compatible with a BTS which has EGPRS (Enhanced General Packet Radio Service) enabled.

15954 ABIS SYNCHRONIZATION FOR PBCCH/PCCCH CHANNEL IS FAILED

Abis synchronization for PBCCH/PCCCH channel is failed and because of that the BSC has downgraded the related channel from GPRS use.

15955 REQUESTED RESTART WAS REJECTED BECAUSE SAME RESTART HAS BEEN REQUESTED PREVIOUSLY.

REQUESTED RESTART WAS REJECTED BECAUSE MORE EXTEN-SIVE RESTART OR EXACTLY THE SAME RESTART HAS BEEN REQUESTED PREVIOUSLY.

15956 RESTART REPLACED BY MORE EXTENSIVE RESTART

Requested restart has been replaced by another restart which is more extensive.

15957 NO SPACE TO SAVE NEW RESTART REQUESTS.

NO SPACE TO SAVE NEW RESTART REQUESTS.

15958 CELL ALREADY HAS ADJACENT CELL WITH THE NEW CGI VALUE

The cell already has an adjacent cell with the same CGI value as the new CGI value of the modified adjacent cell.

15959 SOURCE AND TARGET WCELS MUST HAVE DIFFERENT DL_PRI_SCR_CODE IN ADJS (INTRA-FREQ ADJ)

Target WCELs DL_PRI_SCR_CODE is same as source WCELs DL_PRI_SCR_CODE, so they can not be defined as intra-freq neig-bours (ADJS).

15960 ADDITION OF CALL INSTANCE CODES FAILED

ADDITION OF CALL INSTANCE CODES FAILED

15961 CALL INSTANCE CODE DOES NOT EXIST

CALL INSTANCE CODE DOES NOT EXIST

15962 ONE OR MORE IP ROUTES STILL EXIST

The deletion is unsuccessful as there are still one or more IP routes.

15963 WRONG IDENTITY FOR THE RNW PLAN TO BE ACTIVATED

Page 418: DX Error Messages

418 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The identity of the downloaded RNW plan to be activated is rejected. The plan identity received in activation request must match with the identity of the latest downloaded plan.

15964 USERNAME IS LONGER THAN 6 CHARACTERS.

Given username is longer than 6 characters.

15965 PAYLOAD TYPE IS WRONG

The payload type should be ATM or PPP. Valid payload type is depen-dent on the plug-in unit type.

15966 SCRAMBLING METHOD IS WRONG.

Scrambling method for PPP type of payload can be PPP or no scram-bling. For ATM type of paylod the scrambling should be ATM.

15967 SUBSCRIBER ITSI IS DISABLED

ITSI of subscriber has been disabled.

15968 INTELLIGENT SHUTDOWN FOR ULTRASITE BTS IS NOT IN USE IN BSC

When this option is disabled the intelligent shutdown is not possible for Nokia UltraSite base stations.

15969 INTELLIGENT SHUTDOWN FOR METROSITE BTS IS NOT IN USE IN BSC

When this option is disabled the intelligent shutdown is not possible for Nokia MetroSite base stations.

15970 RESTRICTED BECAUSE THE SUBSCRIBER IS A GROUP

Operation restricted because the subscriber is a group.

15971 THE SUBSCRIBER IS NOT A GROUP

The subscriber is not a group

15972 USER PART OF LSI DOES NOT MATCH WITH BICC TYPE CGR

USER PART OF LSI DO NOT MATCH WITH BICC TYPE CGR

15973 GPRS ENABLED BCCH TRX OF EGPRS BTS NOT IN DYNAMIC ABIS POOL

GPRS enabled (GTRX=Y) BCCH TRX of an EGPRS enabled BTS (EGENA=Y) have to be attached to a Dynamic Abis Pool (DAP).

15974 NO RIGHTS TO NETWORK ELEMENT

User does not have rights to this particular network element or region.

15975 TOO MANY SPCS

Too many Signaling Point Codes in list. Max number is 6 including existing ones.

15976 THE BASE GROUP IS A MEMBER GROUP IN AN OTHER COMBINED GROUP

The base group is a member group in an other combined group.

15977 GROUP IS A MEMBER IN OTHER COMBINED GROUP

Group is member group in an other combined group.

Page 419: DX Error Messages

DN987378Issue 24-0

419

General Error Messages of System DX error messages

Id:0900d8058077e097

15978 THE MEMBER GROUP IS A BASE GROUP OF SOME COMBINED GROUP

The member group is a base group of some combined group.

15979 MEMBER GROUP DOES NOT EXIST

Member group does not exist.

15980 BASE GROUP DOES NOT EXIST

Base group does not exist.

15981 DATABASE REPLICATION, WRONG STATE

The database replication message was received, but the database was in the wrong state.

15982 DATABASE REPLICATION, WRONG SUBSTATE

The database replication message was received, but database was in wrong substate.

15983 INVALID OPERATION.

The requested operation is not supported.

15984 BLOCKED RESOURCE CANNOT HANDLE NEW REQUEST

The requested operation could not be handled because of blocked sit-uation.

15985 PLAN ID INVALID.

An unknown plan identifier is used.

15986 PLAN TYPE UNKNOWN.

The unknown plan type is used.

15987 FILE DATA CORRUPTED OR INVALID.

The content of the file was corrupted or invalid.

15988 INVALID PLAN.

The plan contains syntactical or semantic errors.

15989 REQUEST CANNOT BE HANDLED.

The request cannot be handled.

15990 ACTIVATION FAILED.

Activation failed partly or totally.

15991 ROLLBACK OPERATION ERROR.

Application level error in the rollback operation.

15992 INVENTORY OPERATION ERROR.

Application level error in the inventory operation.

15993 TASK ID UNKNOWN.

The given task identifier does not correspond with any operation waiting to start.

15994 JAMMED OPERATION HAS ALREADY BEEN DELETED.

A jammed operation has been deleted at the mediator.

15995 SCHEMA CORRUPTED OR NOT SUPPORTED BY NE.

Page 420: DX Error Messages

420 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The schema is corrupted or the network element does not support it.

15996 NE DOES NOT SUPPORT TRANSFER PROTOCOL

The network element does not support transfer protocol proposed.

15997 NE DOES NOT SUPPORT TRANSFER CODING.

The network element does not support transfer coding proposed.

15998 NE DOES NOT SUPPORT FIREWALL.

The network element does not support firewall.

15999 NE DOES NOT SUPPORT TRANSFER FIREWALL CONFIGURA-TION.

The network element does not support firewall configuration proposed.

16000 OPEN TRANSFER SESSION FAILED.

The network element cannot open a transfer session to the remote host.

16001 TRANSFER SESSION IS NOT AUTHORIZED.

The network element is not authorized to open transfer session to the remote host, i.e. it uses wrong username/password.

16002 OPEN TRANSFER SESSION TO FIREWALL HOST FAILED.

The network element cannot open a transfer session to the firewall host.

16003 TRANSFER SESSION TO FIREWALL HOST IS NOT AUTHORIZED

The network element is not authorized to open transfer session to the firewall host.

16004 FILE TRANSFER FAILED.

The file transfer failed.

16005 FILE I/O FAILED.

The network element could not write or read the file from its local disk.

16006 CANNOT FIND FILE

The network element could not found the file from disk.

16007 RESOURCE HAS ALREADY BEEN BLOCKED.

The resource has already been blocked.

16008 BLOCK RESOURCE FAILED

Resource block failed.

16009 UNBLOCK RESOURCE FAILED

Unblock resource failed.

16010 RESOURCE HAS ALREADY BEEN UNBLOCKED.

The resource has already been unblocked.

16012 DESTINATION ADDRESS ALREADY IN USE IN THIS INTERFACE

The destination address given has been previously configured for one of this interfaces IP addresses.

16013 ENTERED INGRESS CDVT VALUE TOO LOW, LET THE SYSTEM CALCULATE THE CDVT

Page 421: DX Error Messages

DN987378Issue 24-0

421

General Error Messages of System DX error messages

Id:0900d8058077e097

The system internal calculation is notice entered ingress direction CDVT too low and recommends to let the system calculate, otherwise too low value might cause cell loss. You can repeat the command without entering the CDVT value.

16014 MAXIMUM NUMBER OF CS CN EXCEEDED

Maximum number of CS CN exceeded. Optional features MCN and RAN sharing and IuFlex not ON.

16015 MAXIMUM NUMBER OF PS CN EXCEEDED

Maximum number of PS CN exceeded. Optional features MCN and RAN sharing and IuFlex not ON.

16016 DIFFERENT MNC FOR CN

Same MNC must be defined for each CN.

16017 SAME MNC FOR CN

Different MNC must be defined for each CN.

16018 THE RESOURCES ARE CURRENTLY BLOCKED BY A MASS CON-FIGURATION PROGRAM

The resources are currently blocked by a massy configuration program for exclusive use. The requests from other programs are replied with this error code.

16019 AGERE API FUNCTION WHICH HANDLES TADM HW BLOCK HAS FAILED.

TADM api function has returned error code.

16020 REQUEST FOR SDH PROTECTED TRANSMISSION IS FALSE.

The request for operation of protected sdh transmission is false.

16022 PARAMETER SET ALREADY EXISTS

The given parameter set already exists.

16023 PARAMETER SET DOES NOT EXIST

The given parameter set does not exist.

16024 PARAMETER SET IS IN USE

The given parameter set is in use.

16025 GIVEN VPI BITS EXCEED STORED VPI BITS

Given VPI bits exceed stored VPI bits for NIP unit.

16026 GIVEN VCI BITS EXCEED STORED VCI BITS

Given VCI bits exceed stored VCI bits for NIP unit.

16027 OPERATION NOT ALLOWED FOR STANDARD PARAMETER SET

This operation is not allowed for standard parameter set.

16028 THE NETWORK ELEMENT CONTAINS FAULTY UNITS

The network element contains faulty units (marked with FLTY-status).

16029 CELL ALREADY HAS ADJACENT GSM CELL WITH THE SAME CELL INDEX VALUE

Page 422: DX Error Messages

422 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The cell index is already in use in another GSM cell adjacent to the cell. It is not allowed to create several adjacent GSM cells using the same cell index value for the serving GSM cell.

16030 ADJS (INTRA-FREQ ADJ) AND SOURCE WCEL MUST HAVE DIF-FERENT DL_PRI_SCR_CODE

ADJS (intra-frequency) and source WCEL must have different dl primary scrambling code.

16031 ARFCN + DL_PRI_SCR_CODE PAIR MUST BE UNIQUE WITHIN ADJI (INTER-FREQ ADJ)

UARFCN + DL_PRI_SCR_CODE pair must be unique within ADJI.

16032 INVALID RADIO TIMESLOT TYPE CONFIGURED IN DFCA TRX

Only TCH channels, not in use and SDCCH/8 are allowed RTSL types for DFCA TRX

16033 PRIMARY SCRAMBLING CODE OF AN INTRA-FREQUENCY NEIGH-BOUR CELL MUST BE UNIQUE WITHIN ADJS.

Primary Scrambling Code of an intra-frequency neighbour cell must be unique within ADJS.

16034 PRI SCRC AND UARFCN COMBINATION OF AN INTER-FREQ NEIGHBOUR CELL MUST BE UNIQUE WITHIN ADJI

Primary Scrambling Code and UTRA RF Channel Number combination of an inter-frequency neighbour cell must be unique within ADJI.

16035 GLOBAL CN ID MUST BE UNIQUE

Global CN id must be unique.

16036 MAXIMUM NUMBER OF CBC (CELL BROADCAST CENTER) EXCEEDED

Maximum number of CBC (Cell Broadcast Center) exceeded. Optional feature RAN sharing (Multioperator RAN) or IMSI based HO not ON.

16037 PLMN IDS OF CBC (CELL BROADCAST CENTER) MUST BE UNIQUE

PLMN IDs of CBC (Cell Broadcast Center) must be unique.

16038 CBC (CELL BROADCAST CENTER) MUST BE DEFINED IF SAB (SERVICE AREA BROADCAST) IN USE

CBC (Cell Broadcast Center) must be defined if SAB (Service Area Broadcast) in use.

16039 LCR IDENTIFIER MAY NOT BE CHANGED

The identifier of LCR may not change.

16040 CELL IDENTIFIER MAY NOT BE CHANGED

The identifier of CELL may not change.

16041 UARFCN MAY NOT BE CHANGED

UARFCN may not change.

16042 BAND INDICATOR MAY NOT BE CHANGED

BAND INDICATOR may not change.

Page 423: DX Error Messages

DN987378Issue 24-0

423

General Error Messages of System DX error messages

Id:0900d8058077e097

16043 LOCATION OPTION IS NOT IN USE IN RNC

Location option is not in use in RNC.

16044 INVALID SIGNALLING OR DATA WEIGHTS

IP endpoint configuration error. Illegal signalling or data weights in NSE.

16045 LOCAL UDP-PORT/SOCKET FAILURE

Error in local UDP port configuration or socket failure.

16046 PORT NUMBER ALREADY IN USE

Local UDP port number already exists.

16047 KEY CURRENTLY USED BY IP SECURITY

KEY CURRENTLY USED BY IP SECURITY

16048 MAXIMUM TX POWER OF CELL TOO HIGH DUE TO ATTENUATED CHANNELS GSM1900

If the frequency band used is GSM1900 band, the two channels next to the edge channels of the block must not be used with the maximum transmission power. The FCC, the local regulator in the USA, has set these emission limits for GSM1900 band equipment to ensure that an operator on a certain band does not cause disturbance to another operator on adjacent bands.

16049 WSMLC CANT BE DELETED

WSMLC is being tried to delete, while one ore more WLCSES is using it.

16050 UC ID CANNOT BE MODIFIED

WLCSE dedicated to a certain WCELL, cannot be transferred to another.

16051 INVALID HMS MASTER NODE ADDRESS

Address which has been tried cannot be used to point to any physical or logical address of HMS master node in system.

16052 MA LIST IN USE OF SOME BTS IN DFCA ALGORITHM

MA LIST IN USE OF SOME BTS IN DFCA ALGORITHM

16053 UNKNOWN ADJACENT DFCA MA LIST

UNKNOWN ADJACENT DFCA MA LIST

16054 CS CN ID NOT DEFINED

CS CN id must be given.

16055 PLMN ID NOT DEFINED

PLMN id must be given.

16056 NEEDED OPTION NOT SUPPORTED

The task could not be completed because of missing support for needed optional feature.

16057 RECEIVED TASK ID ALREADY IN USE (RNC OMU)

The task identity received from NEMU in task ID request is already stored and in use in RNW Plan Management in RNC OMU.

16058 ALLOCATION IS REJECTED BECAUSE OF LACK OF BANDWIDTH ON NCID TP.

Page 424: DX Error Messages

424 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Allocation is rejected because of the lack of unallocated bandwidth or too strict delay requirements on NCID tp.

16059 DATABASE UPDATING IS NOT YET READY

The Saver hand of the database disk updating system informs its master that it has written one more logbuffer to database disk files but has not finished its task yet.

16060 GT (GLOBAL TITLE) IS ALTERNATIVE WITH SPC (SIGNALLING POINT CODE)

GT (GLOBAL TITLE) is alternative with SPC (SIGNALLING POINT CODE).

16061 DESTINATION PCM DEFINED TO OTHER PCM

The given destination pcm has been defined to other pcm.

16062 PCM HAS ALREADY BEEN ATTACHED TO OTHER DPCM

The PCM has already been attached to other Destination PCM

16063 PEP IS DISABLED FOR POLICY MANAGEMENT

PEP is disabled for policy management.

16064 COPS CONFIGURATION DATA INVALID

Indicates that the data on configuration file (P0LICEGX.XML) is incon-sistent. Used in alarm cops_configuration_error_a (0x3232).

16065 COPS CONFIGURATION FILE (POLICEGX.XML) HANDLING ERROR

COPS configuration file (P0LICEGX.XML) handling error. COPS Client platform process P0LICE is unable to handle (read, write, access) its configuration file.

16066 YOU CAN ACTIVATE ONLY ONE DFCA MA LIST AT A TIME

You can activate only one DFCA MA list at a time.

16067 THE DXT IS NOT AN EIR EXCHANGE

The DXT in question does not contain an active Equipment Identity Register database.

16068 CS CN IS UNMODIFIABLE

It is not allowed to modify CS CN.

16069 PS CN IS UNMODIFIABLE

It is not allowed to modify PS CN.

16070 WRONG RNC ID IN RNW PLAN

The RNC identity read from the RNW plan differs from the RNC identity stored in RNW database in RNC OMU.

16071 SERVICE CATEGORIES OF VCLTP ARE NOT CORRECT

The ingress and egress service categories of the VCLtp are not correct.

16072 ROUTER NUMBER DOES NOT EXIST

Router number is out of region.

16073 ROUTE TYPE IS NOT FOR AAL2 OR EXTERNAL

Route type is not for AAL2 or external.

Page 425: DX Error Messages

DN987378Issue 24-0

425

General Error Messages of System DX error messages

Id:0900d8058077e097

16074 TIMER IS OUT

Timer is out.

16075 THE CHANNEL DOES NOT EXIST

The channel does not exist.

16076 THERE IS NO VCCEP

There is no vccep in ARFILE.

16077 THE ENDPOINT EXISTS ALREADY

When creating a new endpoint, find the endpoint has already existed.

16078 ANI IS NOT CONSISTENT

ANI is not consistent.

16079 INVALID TTMC FPGA INDEX

Invalid TTMC FPGA index in IW1S1 unit. Suitable values are 0 to 2.

16080 INVALID PCM OPERATION MODE

Invalid PCM operation mode in IW1S1 unit. Suitable values are E1, T1, or JT1.

16081 INVALID USER DATA PACKET LENGTH

Invalid TTMC user data packet length. Configure how many time slots TTMC collects in one packet before it sends the packet.

16082 INVALID LOCAL SS7 PCM NUMBER

Invalid local SS7 PCM number. In T1 mode local PCM number range is 0 to 83. In E1 mode local PCM number range is 0 to 62.

16083 INVALID SS7 TIMESLOT NUMBER

Invalid SS7 timeslot number. Maximum value is 23 in T1/JT1 mode and 31 in E1 mode. SS7 time slot is separated from user data in TTMC.

16084 SS7 PCM AND TIMESLOT COMBINATION ALREADY EXIST

SS7 PCM and time slot combination is already configured in the system.

16085 TTMC I/0 REGISTER WRITE FAILURE

TTMC I/O register write failure. Writing to TTMC HW is not possible.

16086 NO FREE PCM TIMESLOTS FOR SS7 USAGE

No free PCM time slots for SS7 usage. Between TTMC and Master PQII there is only 2Mbit/s TDM link available.

16087 RNW PLAN ACTIVATION COMPLETED WITH EXCEPTIONS

The RNW plan activation operation has been completed with certain exceptions. Some of the modifications to the actual RNW configuration may have been skipped. Check operation feedback and RNC OMU log for more detailed information.

16088 PRIMARY SCRAMBLING CODE MUST BE SAME FOR WCEL AND INCOMING ADJACENCY (ADJS)

The primary scrambling code must be same for WCEL and incoming adjacency (ADJS).

16089 PRIMARY SCRAMBLING CODE MUST BE SAME FOR THE WCEL AND THE INCOMING ADJACENCY (ADJS)

Page 426: DX Error Messages

426 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The primary scrambling code must be same for WCEL and incoming adjacency (ADJS).

16090 SAC_B MUST BE DEFINED IF SAB ACTIVE

SAC_B must be given if SAB (Service area broadcast) is active.

16091 CTCH_CAPA_CBS_MSG MUST BE DEFINED IF SAB ACTIVE

CTCH_CAPA_CBS_MSG must be given if SAB (Service area broad-cast) is active.

16092 K_CTCH MUST BE DEFINED IF SAB ACTIVE

K_CTCH must be given if SAB (Service area broadcast) is active.

16093 N_CTCH MUST BE DEFINED IF SAB ACTIVE

N_CTCH must be given if SAB (Service area broadcast) is active.

16094 DN OF ADJC IS NOT USED CORRECTLY ACCORDING TO OPTION ADJC_INDEX_USAGE_IN_Q3

The DN (Distinguished Name) of the ADJC (Adjacent Cell) object is not used correctly according to the value of option ADJC_INDEX_USAGE_IN_Q3.

16095 LAC/CI PAIR IS NOT UNIQUE IN BSC RNW DATABASE AND CGI NOT FULLY SUPPORTED IN DN OF ADJC

LAC (Location Area Code) and CI (Cell Identity) pair is not unique in BSC (Base Station Controller) RNW (Radio Network) database and CGI (Cell Global Identity) is not fully supported in DN of ADJC (Adjacent Cell) object.

16096 RNC ID MUST BE UNIQUE

RNC id must be unique within Iur interface list and own RNC.

16097 PLMN ID MUST BE UNIQUE

PLMN id must be unique within Iur interface list.

16098 SIGNALLING POINT CODE MUST BE UNIQUE

Signalling Point Code must be unique within Iur interface list.

16099 RNW OBJECT AUTOMATIC LOCKING OR UNLOCKING FAILED

The required automatic locking or unlocking of the RNW object (WCEL) has failed during RNW plan operation in RNC OMU. Either the opera-tion directed to this object has been cancelled because WCEL(s) could not be locked, or the unlocking of WCEL(s) after the operation has failed.

16100 UNKNOWN ADJACENT DFCA MA LIST FOR ALGORITHM

UNKNOWN ADJACENT DFCA MA LIST FOR DFCA ALGORITHM

16101 MA LIST USED BY SOME BTS IN DFCA ALGORITHM

MA LIST USED BY SOME BTS IN DFCA ALGORITHM

16102 IP ADDRESS NOT DEFINED FOR CBC

At least one IP address must be defined for CBC.

16103 NO RESOURCES AVAILABLE FOR REQUESTED DSP SERVICE TYPE IN ANY UNIT

Page 427: DX Error Messages

DN987378Issue 24-0

427

General Error Messages of System DX error messages

Id:0900d8058077e097

DSP resource manager cannot allocate requested service to any DSP unit because of a resource shortage of some sort. Possibly many units are searched and the reason for shortage may be different depending on unit.

16104 INTERNAL DATA ERROR OCCURED IN RM3PRB

Internal error in data handling or in program logic.

16105 GIVEN DSP SERVICE TYPE IS OUT OF BOUNDS OR NOT IN USE

Given service type is incorrect because DSP resource manager does not recognize service type as an allowed DSP service.

16106 GIVEN CLIENT OWNER ID IS INCORRECT

Client owner ID is out of bounds or otherwice faulty.

16107 GIVEN SERVICE ID DOES NOT EXISTS

RM3 cannot find the given service identifier from the list of active ser-vices.

16108 RESOURCE SHORTAGE IN ACCEPTABLE UNIT SET

Resource shortage because the search for capacity is limited to certain units. (limited e.g. by destination service and force destination flag)

16109 RESOURCE SHORTAGE BECAUSE OF NON ACTIVE DSP STATE

Resource shortage because of non active state of DSP unit when only certain DSP is accepted.

16110 DSP UNITS PARENT IS NOT IN ACTIVE STATE (TCU/TPG OR DMCU/DMPG)

Resource shortage because of non active state of DSPs some parent level unit.

16111 IP CONNECTION REQUIRED BY SERVICE TYPE NOT AVAILABLE

Requestred service type requires active IP connection, but connection is not found.

16112 SERVICE IS ALREADY RELEASED OR IT WAS NEVER CREATED

Service release is not succesful because the service does not exists.

16113 UNKNOWN MESSAGE RECEIVED BY UPIPRB

A task of UPIPRB has failed because it has received a message it does not know how to handle.

16114 UPIPRB HAS FAILED TO REINITIALIZE DRIVER

UPIPRB has initialized more than once, but the driver informs it has not been initialized. This is a result of a serious error in the system.

16115 INTERNAL ERROR HAS OCCURRED IN UPIPRB

Something has gone internally wrong with UPIPRB.

16116 OPTIONAL FEATURE OF CONNECTSITE IS NOT ALLOWED BY BTS

Using of an optional feature of the Connectsite BTS is not allowed in BTS.

16117 UNSUPPORTED SW PACKAGE FOR CONNECTSITE IS REJECTED BY BTS

Page 428: DX Error Messages

428 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Unsupported SW package for Connectsite BTS is rejected by BTS.

16118 NEW OBJ_UNIT/SERVICE SUBSCRIPTION

Riesen/qieser has a new obj_unit/service subscription.

16119 TOO FEW FREQUENCIES ON DFCA UNSYNCHRONIZED MODE MA LIST

The number of frequencies in DFCA unsynchronised mode MA list must be at least 2 * n - 1, where n is the number of DFCA TRXs in the BTS.

16120 SOME LAN HW SUPERVISION FILE IS CORRUPTED

The data of some LAN HW Supervision related file has been corrupted.

16121 UNKNOWN LAN DEVICE

The given LAN device is not recognised by LAN HW Supervision.

16122 ILLEGAL OPERATION TO LAN DEVICE

The LAN device does not support the given task.

16123 LAN HW SUPERVISION BUSY

The program block AKSELI is not capable of receiving new tasks. Try again after a while.

16124 IP OVER ATM CONNECTION BETWEEN THESE TWO UNITS IS NOT ALLOWED

An IPoA connection between the given two units is not allowed.

16125 PLMN ID FOR NEIGHBOURING RNC NOT DEFINED

At least one PLMN id must be defined for neighbouring RNC.

16126 PLMN IDS OF NEIGHBOURING RNC MUST BE UNIQUE

PLMN ID:s of neighbouring RNC must be unique.

16127 RNC ID + PLMN ID PAIR MUST BE UNIQUE WITHIN IUR LIST (NEIGHBOURING RNC LIST)

RNC id + PLMN id pair must be unique within Iur list (neighbouring RNC list).

16128 INCORRECT CALL IDENTIFIER

The request has gone to the wrong call. The identifier did not match.

16129 REQUESTED RESOURCE NOT FOUND

The requested resource not found from call.

16130 CALL PARAMETERS ARE NOT CORRECT

The requested parameters are not correct or some other internal error has happened.

16131 LEG IS NOT BRANCHABLE

The requested leg is not branchable so the operation is not possible.

16132 FREE RESOURCE INDEXES DID NOT FOUND

The free space is not found to new resources.

16133 LEG RESOURCE IS LOCKED

The requested leg is locked for adoption operation.

16134 VIRTUAL TOPOLOGY CHANGE FAILED

Page 429: DX Error Messages

DN987378Issue 24-0

429

General Error Messages of System DX error messages

Id:0900d8058077e097

The virtual topology change failed. The realised leg has been removed and the virtual leg has been put back to the call.

16135 TRAFFIC PARAMETERS ARE DIFFERENT

The traffic parameters are different in legs.

16136 STARTING REFRESH FAILED

The starting of hand process refresh has been failed.

16137 ACTION NOT ALLOWED DURING TRIAL CONFIGURATION

Action which has been tried to do is not allowed as long as trial config-uration exists.

16138 THE SERVICE MODIFICATION HAS FAILED

The service modification has failed for some reason. Maybe some counterpart has sent an error code in ack message.

16139 RESOURCE IS ALREADY SEIZED

The resource has already been reserved.

16140 THE TABLE INDEX IS TOO HIGH OR INCORRECT

The resource table index is too high or it is incorrect.

16141 PRID OR DEST HAS BEEN INCORRECTLY SET

The prid or dest information has been incorrectly set to request.

16142 RESOURCE TYPE HAS BEEN INCORRECTLY SET

The resource type has been incorrectly set to request.

16143 RESOURCE IS NOT SEIZED

The resource is not reserved yet. Operation cannot be executed.

16144 LEG IS BRANCHABLE

The requested operation cannot be made to a branchable leg.

16145 ANOTHER ADOPTION IS ONGOING

Another adoption operation is ongoing.

16146 ERROR IN SNMP PACKET

Error number 2 in NET-SNMP code.

16147 SEQUENCE NUMBER WRAPPED-AROUND

The individual sequence number has reached its maximum value and wrapped-around. A new USIM is needed.

16148 SUPERVISOR UNIT OF LAN SWITCH IS NOT IN WO STATE

Supervisor unit of LAN switch is not in wo state. To add a LAN switch the supervisor unit must be in wo state.

16149 SUPERVISOR UNIT OF LAN SWITCH DOES NOT EXIST IN INTERNAL LAN CONFIGURATION (LAUDAT)

The supervisor unit of LAN switch does not exist in the internal LAN con-figuration (LAUDAT). A LAN switch can only be added if it has a super-visor unit in the internal LAN configuration.

16150 SWITCH WAS NOT FOUND FROM LAN TOPOLOGY

Page 430: DX Error Messages

430 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Switch was not found from LAN topology management. See MML-command group W6.

16151 REMOVING OF ACTIVE SWITCH NOT ALLOWED

Removing of active switch is not allowed from LAN topology manage-ment. See MML-command group W6.

16152 SUPERVISION UNIT IN USE

The supervision unit is currently supervising a LAN switch and cannot be removed.

16153 TOO MANY ITEMS IN CBC LIST

The XML file processing program block (PABROS, RNC OMU) has found too many cbc_list items in the RNW Plan file.

16154 TOO MANY PLMN IDS FOR CBC

The XML file processing program block (PABROS, RNC OMU) has found too many PLMN IDs for CBC.

16155 TOO MANY DNBAP ITEMS FOR COCO OBJECT

The XML file processing program block (PABROS, RNC OMU) has found too many DNBAP items in the COCO object.

16156 TOO MANY ITEMS IN AAL2SIG LIST

The XML file processing program block (PABROS, RNC OMU) has found too many aal2sig items in the RNW plan file.

16157 TOO MANY ITEMS IN AAL2TP LIST

XML file processing program block (PABROS, RNC OMU) has found too many aal2_tp items in the RNW plan file.

16158 NO CERTIFICATE ENROLLMENT POINT DEFINED

No certificate enrollment point defined.

16159 NO RESPONSE FROM CERTIFICATE ENROLLMENT POINT

No response from certificate enrollment point.

16160 KEY DATABASE OPERATION FAILED

Malfunction in IPSec key database operation.

16161 CMP PRE-SHARED KEY NOT VALID

Content of pre-shared key used in CMP enrollment not valid.

16162 TOO MANY IP ADDRESSES FOR CBC

The XML file processing program block (PABROS, RNC OMU) has found too many IP addresses for CBC in the RNW plan file.

16163 THE STATE CHANGE OF UNIT IS NOT POSSIBLE SINCE THE STATE OF PAIR UNIT IS NOT WO

The state change of unit is not possible controlled since the state of the unit pair is not working.

16164 ANOTHER UPDATE REQUEST FOR THE UPC/NPC MODE IS ONGOING

The system is busy with a modification of the UPC/NPC mode of some access profile. Only one such request can be handled at a time. Inter-

Page 431: DX Error Messages

DN987378Issue 24-0

431

General Error Messages of System DX error messages

Id:0900d8058077e097

rogate the access profile in question to see when the current request has finished. Then issue the same command again.

16165 NO RECORD FOUND

Inquiry failed, cannot find interfaces that match the parameters.

16166 YANLIB NO SERVICE NOW

YANLIB cannot provide service now.

16167 NO TPI STATE INFO IN YANLIB

YANLIB cannot provide tpi state service now.

16168 INVALID INPUT PARAMETERS

Invalid input parameter.

16169 YANLIB INTERNAL ERROR

Some internal error occurred in YANLIB.

16170 YANLIB OCCURS COMMON BUFFER ERROR

The error occurred during YANLIB operating common buffer.

16171 NO CHANGE AFTER YANLIB UPDATE

Nothing changed after YANLIB update state.

16172 NO SERVICE OR NOT INITIALIZED

No service, or not initialized yet.

16173 APPLICATION REGISTER INFO ILLEGAL

The register information sent by the application is illegal.

16174 EXCEEDED MAX REGISTER APPLICATIONS

The maximum number of register information has been exceeded.

16175 MESSAGE QUEUE HAS BECOME FULL. INCOMING REQUESTS WILL BE REJECTED.

The process message queue has become full.

16176 CENTER NODE SWITCHOVER DURING START UP HAS EXE-CUTED.

Post office informs that switchover of center node has happened during startup.

16177 TOO MANY PAPU UNITS ACTIVE

More than 8 PAPU units active (WO-XX,XX is EX/RE etc.)

16178 NOT ENOUGH PAPU UNITS ACTIVE

Less than 8 PAPU units active (WO-XX,XX is EX/RE etc.)

16179 NOT ENOUGH SMMU UNITS ACTIVE

Less than 4 SMMU units are active (WO-XX,XX is EX/RE etc.).

16180 NOT ENOUGH IOCP MEMORY

Memory limit in IOCP unit, 1 GB memory is needed.

16181 OLD IOCP UNIT TYPE

IOCP type C is needed.

16182 MAX NUMBER OF HCPAPU UNITS ALREADY DEFINED

Page 432: DX Error Messages

432 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

4 HCPAPUs already exists.

16183 UNIT ALREADY IN REQUESTED MODE

PAPU is already in the requested mode.

16184 ONE OR MORE HCPAPU UNITS IN HC MODE

In order to deactivate the HCPAPU feature, all PAPUs must be in NC mode.

16185 HCPAPU FEATURE ALREADY ACTIVATED

HCPAPU feature is already activated.

16186 SNMP ERROR IN QUERIES

An error has occurred in NET-SNMP query.

16187 SWITCH NOT FOUND IN XML FILE

No data in the XML file concerning this type of switch.

16188 ID NOT FOUND IN THE XML FILE

Unable to find the current ID in the XML file.

16189 XML-FILE IS CORRUPTED

Unable to read the contents of the XML file.

16190 TOO MANY OPERATIONS IN QUEUE

Buffer for current operation (wheather SNMP GET or SET) is full.

16191 WANE ALREADY CREATED

A Wane (WANE) object with the given identity already exists in the radio network database.

16192 WANE COLLECTION FULL

There is no room for a new Wane (WANE) object in the radio network database.

16193 WANE NOT FOUND

The Wane (WANE) object cannot be found in the radio network data-base.

16194 WSG ALREADY CREATED

The Wsg (WSG) object with the given identity already exists in the radio network database.

16195 WSG COLLECTION FULL

There is no room for a new Wsg (WSG) object in the radio network data-base.

16196 WSG NOT FOUND

The Wsg (WSG) object cannot be found in the radio network database.

16197 PREVIOUS RESET SEQUENCE NOT YET COMPLETED

A new reset sequence through HMS has been requested before the previous one was completed. The requested reset has not been exe-cuted. Try again later.

16198 NO RESOURCES AVAILBLE FOR SERVICE BECAUSE ANY DSP IS NOT STARTED

Page 433: DX Error Messages

DN987378Issue 24-0

433

General Error Messages of System DX error messages

Id:0900d8058077e097

The DSP resource manager cannot allocate the requested service to any DSP unit because no DSP unit is loaded.

16199 REQUESTED DSP SERVICE TYPE IS NOT LOADED TO ANY UNIT

The DSP resource manager cannot allocate the requested service to any DSP unit because the service type is not on the loading list; i.e. a DSP startup could have occurred but the requested service is not loaded.

16200 MAXIMUM OF WSGS FOR WANE

The Wane (WANE) already has a maximum amount of Wsgs (WSG).

16201 UNKNOWN PARAMETER FOR WANE IN RNW PLAN

The XML file processing program block (PABROS, RNC OMU) has detected an unknown (or incorrectly placed) WANE object parameter in the RNW Plan file.

16202 UNKNOWN PARAMETER FOR WSG IN RNW PLAN

The XML file processing program block (PABROS, RNC OMU) has detected an unknown (or incorrectly placed) WSG object parameter in the RNW Plan file.

16203 ERROR IN POST A MESSAGE TO A MESSAGE QUEUE

The error code is returned when the system fails to put a message into a message pool.

16204 THERE ARE WSG RELATED TO WANE

A WANE object must not be deleted if it has relations to WSG objects.

16205 DEFAULT WANE CANNOT BE DELETED

The WANE object must not be deleted if the value of wane_id is used as default Authorized Network Id in the RNC object.

16206 IMSI BASED HANDOVER OPTION IS NOT IN USE IN RNC

IMSI-based Handover option is not supported.

16207 NO MORE MAC ADDRESSES CAN BE FOUND FROM THE PLUG-IN UNIT

With this error code POFFIC notifies TOMPRB that it has already sent all the MAC addresses that can be found to TOMPRB and no more MAC addresses can be found from the plug-in unit.

16208 NO LDAP SERVER DEFINED FOR COMPUTER UNIT

No LDAP server is defined for the computer unit in question.

16209 TIMEOUT WHEN CONNECTING TO LDAP SERVER

Timeout when connecting to LDAP server.

16210 LDAP SERVER DENIES ACCESS

LDAP server denies access.

16211 INVALID DN SYNTAX

Invalid DN syntax.

16212 NO CERTIFICATES FOUND

No certificates found in LDAP directory.

Page 434: DX Error Messages

434 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16213 FOUND MULTIPLE CERTIFICATES

Multiple certificates were found.

16214 LDAP SERVER INDICATES IT IS BUSY

LDAP server indicates it is busy.

16215 LDAP SERVER INDICATES IT IS UNAVAILABLE

LDAP server indicates it is unavailable.

16216 LDAP SERVER INDICATES IT IS UNWILLING TO PERFORM

LDAP server indicates it is unwilling to perform.

16217 PROTOCOL ERROR WHEN INTERACTING WITH LDAP SERVER

Protocol error when interacting with LDAP server.

16218 TIMEOUT WHEN SEARCHING OBJECTS FROM LDAP SERVER

Timeout when searching objects from LDAP server.

16219 SIZE OF FOUND LDAP OBJECT TOO BIG TO HANDLE

Size of found LDAP object too big to handle.

16220 LDAP FETCH OPERATION BUSY

LDAP fetch operation busy. Try again soon.

16221 UNEXPECTED MALFUNCTION

Unexpected malfunction. Error logs and/or alarms describe the problem.

16222 WRONG PCU TYPE

The type of the PCU card is incorrect.

16223 PATH TRACES OF SETS DO NOT MATCH

The path traces of SETs have to be the same when creating a protec-tion group. If the SETs are in VC4 mode, only one path trace pair has to match. If the SETs are in VC3 mode, all three path trace pairs must match.

16224 THERE IS A CONFLICT IN THE TRIAL CONFIGURATION

The Trial information in the SOMAFI file on the disk and NE_SPLIT system variable are conflicting.

16225 NO SUCH RNW PLAN INFORMATION AVAILABLE IN RNC OMU

RNW Plan Manager (RAYMAN) in RNC OMU has received information request of latest downloaded/activated RNW plan but no such plan information exists. There might be no RNW plan ever downloaded/acti-vated or, for some other reason the plan operation history is cleared.

16226 DOWNLOADED AND NOT YET ACTIVATED RNW PLAN IN RNC OMU

The RNW Plan Manager (RAYMAN) in RNC OMU has discovered that a new download attempt would overwrite an old, not yet activated RNW plan. This error code is returned as a warning when reserving a new task_id. Despite this error code, operation can be continued normally.

16227 TASK ID OF ACTIVE RNW PLAN TO BE ROLLBACKED WRONG OR NOT FOUND

Page 435: DX Error Messages

DN987378Issue 24-0

435

General Error Messages of System DX error messages

Id:0900d8058077e097

The RNW Plan Manager (RAYMAN) in RNC OMU has noticed that the task_id request for rollback includes a wrong activation task_id or the activaction task_id has not been found.

16228 INVALID PASSWORD FOR TELNET LOGIN

LAN device topology management has wrong password for telnet login.

16229 FAILURE DURING TELNET OPERATION

Telnet operation failed.

16230 SYSTEM CLOCK IS NOT SYNCHRONISED TO ANY REFERENCE

The system clock has not been synchronised to any synchronisation reference and therefore the desired operation is unsuccessful.

16231 THE VCLTP FOR AAL2 USER DATA IS CURRENTLY NOT CON-NECTED. INCREASING PCR IS PROHIBITED

It is currently not allowed to increase the PCR of the VCLtp for AAL TYPE 2 user data because it is not connected. A PCR increase could not be checked by CAC. The N_CID connection does not exist because of an A2SP restart or due to lack of AAL TYPE 2 capacity in the A2SPs. Check the states of the A2SP units and retry the command when all are WO-EX. If still unsuccessful you need to add A2SP units to the system.

16232 DATABASE REPLICA STATE NOT ALLOWED

Database replication was attempted, but the replica state is not allowed.

16233 DATABASE REPLICATION TERMINATED BY USER

Database replication has been terminated by user command.

16234 ATTEMPT TO USE LOCKED CONNECTION

Some of the connections handled by database dump library have been locked. An attempt to use a locked connection has been made.

16235 RNW PLAN OPERATION HAS BEEN ABORTED BY USER

The RNW plan operation has been interrupted in RNC OMU due to an abort request from NetAct (via NEMU).

16236 PAPU GROUP ALREADY EXISTS

The papu group already exists in the GPDATA database.

16237 PAPU GROUP IS NOT FOUND

Papu group is not created in the GPDATA database.

16238 PAPU IS NOT FOUND

Papu is not found in the papu group in the GPDATA database.

16239 PAPU ALREADY EXISTS

Papu has already been created in the papu group in the GPDATA data-base.

16240 NSEI BELONGS TO SINGLE PAPU

NSEI belongs to a single papu; that is, NSEI does not belong to a papu group in the GPDATA database.

16241 TOO MANY CELLS

The maximum amount of cells was exceeded in the papu group.

Page 436: DX Error Messages

436 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16242 SIGNALLING BVC RESET ONGOING

The signalling BVC reset / PTP BVC reset is ongoing. Command exe-cution is not possible at the moment.

16243 ROUTING AREA IDENTIFICATION NOT FOUND

Routing area identification ( RAC + LAC + MCC + MNC ) was not found in the GPDATA database.

16244 RAI BELONGS TO PAPU GROUP

Routing Area Identification (RAC+LAC+MCC+MNC) belongs to papu group.

16245 RAI BELONGS TO SINGLE PAPU

Routing Area Identification belongs to single papu.

16246 BSC DB AND PCU CONFIGURED OK BUT NO RESPONSE RECEIVED FROM SGSN, STILL TRYING

The requested configuration has been updated successfully at the local end (BSC db and PCU), but the remote end (SGSN) has not yet been configured. The system is still trying to send the configuration to the remote end.

16247 EQOS FEATURE IS NOT IN USE IN BSC

EQoS (Enhanced Quality of Service) support in BSC (Base Station Controller) feature is a collection of enhancements to allow traffic class and guaranteed bitrate support in BSS (Base Station Subsystem).

16248 IBHO WCDMA FEATURE IS NOT IN USE IN BSC

IBHO (IMSI Based Handover) WCDMA in BSC (Base Station Control-ler) feature enables IMSI (International Mobile Subscriber Identity) based handovers between GSM and WCDMA networks.

16249 IBHO GSM FEATURE IS NOT IN USE IN BSC

IBHO (IMSI Based Handover) GSM in BSC (Base Station Controller) option enables IMSI (International Mobile Subscriber Identity) based handovers between GSM networks.

16250 NACC FEATURE IS NOT IN USE IN BSC

NACC (Network Assisted Cell Change) enables the MS (Mobile Station) to receive (when in packet transfer mode) neigbour cell system informa-tion messages in serving cell before the cell reselection is executed. When enabled also the packet SI (System Information) status support is activated.

16251 CS3 CS4 FEATURE IS NOT IN USE IN BSC

CS3 and CS4 (Coding Scheme CS3 and CS4) feature enables coding schemes for higher data rates (14.4 and 20.0 kbps).

16252 FEATURE GB OVER IP IS NOT INSTALLED OR NOT ACTIVE IN THE BSC

Requested management operation can not be executed because feature Gb over IP is not installed or activated in the BSC. Check the status of this feature from the BSC.

16253 IP ROUTE REACHABILITY CHECKING FAILED

Page 437: DX Error Messages

DN987378Issue 24-0

437

General Error Messages of System DX error messages

Id:0900d8058077e097

The gateway of the given static route is unreachable via any predefined IP address with the same type (physical/logical IP address) in the unit; e.g. the unit does not have an IP address in the same subnet as the gateway.

16254 PBB+PAB >= 12, NO BLOCKS FOR PAGING, PAGING NOT POSSIBLE ON PCCCH

PBB + PAB >= 12. No blocks for paging, paging not possible on PCCCH.

16255 WSTA ALREADY CREATED

A Wsta (WSTA) object with the given identity already exists in the radio network database.

16256 WSTA COLLECTION FULL

There is no room for a new Wsta (WSTA) object in radio network data-base.

16257 SIGNALLING UNIT IS FULL, NO MORE TRANSCEIVERS NOR BCFS CAN BE CREATED IN SAME UNIT

The maximum combined number of transceivers and BCFs allowed in the signalling unit has been reached. Another signalling unit should be used.

16258 THERE ARE TOO MANY BTSS IN ONE BCF

The maximum number of BTSs is already created into BCF.

16259 WSTA NOT FOUND

The Wsta (WSTA) object cannot be found in the radio network data-base.

16260 LCEL ALREADY CREATED

The Lcel (LCEL) object with the given identity is already created in radio network database.

16261 LCEL COLLECTION FULL

There is no room for a new Lcel (LCEL) object in radio network data-base.

16262 LCEL NOT FOUND

The Lcel (LCEL) object cannot be found in radio network database.

16263 LCEG ALREADY CREATED

The Lceg (LCEG) object with the given identity is already created in radio network database.

16264 LCEG COLLECTION FULL

There is no room for a new Lceg (LCEG) object in radio network data-base.

16265 LCEG NOT FOUND

The Lceg (LCEG) object cannot be found in radio network database.

16266 MAXIMUM OF LCELS UNDER LCEG

There is no room for a new Lcel (LCEL) under this Local Cell Group (LCEG).

Page 438: DX Error Messages

438 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16267 MAXIMUM OF LCELS UNDER WBTS

There is no room for a new Lcel (LCEL) under this Base Station (WBTS).

16268 MAXIMUM OPENIUB CELL LICENSE NUMBER EXCEEDED

All Open Iub cell licenses are exhausted.

16269 OCNS OBJECT NOT FOUND

Orthogonal Channel Noise Simulator (OCNS) object not found in the radio network database.

16270 SYSTEM INFOS NOT UPDATED

System information messages have not been updated.

16271 CELL NOT FOUND

Cell not found

16272 WLMU ALREADY CREATED

The WLMU object already exists in the radio network database.

16273 NCCR FEATURE IS NOT IN USE IN BSC

NCCR (Network Controlled Cell Re-Selection) feature makes possible for the network to control timing and target cell selection in cell re-selec-tion.

16274 WLMU NOT FOUND

WLMU object cannot be found in the radio network database.

16275 REFERENCE GPS WLMU NOT FOUND

Reference GPS WLMU of WLCSE cannot be found in the radio network database.

16276 REFERENCE DGPS WLMU NOT FOUND

The reference DGPS WLMU of WLCSE cannot be found in the radio network database.

16277 NO DHCP SERVER IN SUPERVISION UNIT

Supervision unit must have the TFDHCP process running.

16278 NACC ADJACENT CELL UPDATE FAILED

Adjacent cell update information handling failed.

16279 NACC SI MESSAGE UPDATE FAILED

NACC-related SI message handling failed.

16280 NACC PSI MESSAGE UPDATE FAILED

NACC-related PSI message handling failed.

16281 NACC ADJACENT CELL SI MESSAGE UPDATE FAILED

NACC related adjacent cell SI message handling failed.

16282 NACC SI OR PSI MESSAGE STORING FAILED

Storing of NACC-related SI or PSI messages to PCU failed.

16283 LAN UNIT PASSIVE IN TOPOLOGY

A passive LAN unit cannot be supervised. Activate unit in LAN topology.

Page 439: DX Error Messages

DN987378Issue 24-0

439

General Error Messages of System DX error messages

Id:0900d8058077e097

16284 MAXIMUM NUMBER OF BTSS IN PCU EXCEEDED

Maximum number of BTSs in PCU exceeded.

16285 FAILED WHILE IDENTITY IS NOT PRIMARY

1. Client tried to use DMX identity which should be primary DMX identity to perform requested action. 2. Reservation of primary DMX identity failed due to incorrect parameters. 3. Reservation of secondary DMX identity failed while identity is not primary.

16286 DMX IDENTITY IS SECONDARY

The client used a secondary DMX identity to perform an action that needs a normal or primary identity.

16287 PRIMARY DMX IDENTITY ALREADY HAS MAXIMUM AMOUNT OF SECONDARY DMX IDENTITIES

The client tried to reserve a secondary DMX identity, but the primary identity cannot accommodate any more secondary identities.

16288 NO RNW PLAN OPERATION ONGOING

The RNW Plan Manager program block RAYMAN in RNC OMU has rejected the plan operation abort request. No plan operation is ongoing.

16289 BSR SUPPORT FEATURE IS NOT IN USE IN BSC

The BSR (BCCH Super Reuse) feature in BSC (Base Station Control-ler) enables the reusing of BCCH frequencies without interfering with the same frequencies on the regular layer.

16290 MAXIMUM OF LCEGS UNDER WBTS

There is no room for a new Lceg (LCEG) under this Base Station (WBTS).

16291 TARGET UNIT IS NOT RESPONDING

Target unit is not responding.

16292 INTERFACE DOES NOT EXIST

Interface does not exist.

16293 SERVICE IS NOT CONFIGURED IN CURRENT INTERFACE

Service is not configured in current interface.

16294 ALL UNLOCKED SLAVE BCFS TO BE RESTARTED AUTOMATI-CALLY AFTER MASTER CLOCK BCF UNLOCK

ALL UNLOCKED SLAVE BCFS TO BE RESTARTED AUTOMATI-CALLY AFTER MASTER CLOCK BCF UNLOCK

16295 PCU CAPACITY LICENCE EXCEEDED

PCU capacity licence is exceeded.

16296 PCU2 CAPACITY LICENCE EXCEEDED

The PCU2 capacity licence has been exceeded.

16297 DFCA TRX CAPACITY LICENCE EXCEEDED

DFCA TRX capacity licence exceeded.

16298 ETRX CAPACITY LICENCE EXCEEDED

ETRX capacity licence is exceeded.

Page 440: DX Error Messages

440 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16299 AMR HR TRX CAPACITY LICENCE EXCEEDED

AMR HR TRX capacity licence is exceeded.

16301 LCEG OBJECT IS NOT ALLOWED TO BE DELETED IF RELATION TO LCEL OBJECT EXISTS

LCEG object is not allowed to be deleted if relation to LCEL object exists.

16302 GPRS CONTROL PARAMETERS NOT FOUND IN DATABASE

GPRS control parameters not found in database.

16303 CORRUPTED ETHERNET EEPROM

This indicates a corrupted ethernet EEPROM.

16304 ADDRESS IS NOT UNICAST

The given ethernet MAC address is not an unicast one.

16305 SUBSCRIBER GROUP WAS NOT FOUND IN RNW DATABASE

The subscriber group has not been created in the RNW database.

16306 AUTHORISED NETWORKS WAS NOT FOUND IN RNW DATABASE

The Authorised Networks has not been created in the RNW database.

16307 ILLEGAL SUBSCRIBER GROUP IDENTIFIER

Illegal subscriber group identifier.

16308 ILLEGAL AUTHORISED NETWORKS IDENTIFIER

Illegal Authorised Networks identifier.

16309 SOFTWARE BUILD ID ALREADY EXIST

Requested software build id already exist.

16310 SOFTWARE BUILD FILE IS FULL

Software build file is full.

16311 SOFTWARE BUILD DOES NOT EXIST

Requested software build id does not exist.

16312 AUTHORISED NETWORKS NAME ALREADY IN USE

The name of Authorised Networks is already in use by another Autho-rised Networks.

16313 REQUESTED STATUS ALREADY HAS AN ATTACHMENT

Requested status already has an attachment.

16314 REQUESTED STATUS HAS NO ATTACHMENT

Requested status has no attachment.

16315 SUBSCRIBER GROUP NAME ALREADY IN USE

The name of Subscriber Group is already in use by another Subcriber Group.

16316 NETWORK ELEMENT GROUP ID ALREADY EXIST

Network element group id already exists.

16317 AUTHORISED NETWORKS CANNOT BE DELETED

Page 441: DX Error Messages

DN987378Issue 24-0

441

General Error Messages of System DX error messages

Id:0900d8058077e097

The Authorised Networks cannot be deleted if any of Subscriber Groups are attached to the The Authorised Networks.

16318 NETWORK ELEMENT GROUP FILE IS FULL

Network element group file is full.

16319 IMSI ALREADY IN USE

The IMSI of Subscriber Group is already in use by another Subcriber Group.

16320 NETWORK ELEMENT GROUP HAS A DEFAULT BUILD

Network element group has a default build.

16321 NCCR AND NACC FEATURES ARE NOT IN USE IN BSC

Measurement error code is received when NCCR (Network Controlled Cell Re-Selection) and NACC (Network Assisted Cell Change) features are not enabled but measurement is trying to be managed.

16322 IBHO FEATURES ARE NOT IN USE IN BSC

Measurement error code is received when IBHO (IMSI Based Han-dover) GSM (Global System of Mobile Communications) and IBHO WCDMA (Wideband Code Division Multiple Access) features are not enabled but measurement is trying to be managed.

16323 UL SF NOT SUPPORTED

The concerned cell(s) do not support the requested minimum UL SF (spreading factor).

16324 DL SF NOT SUPPORTED

The concerned cell(s) do not support the requested DL SF (spreading factor).

16325 COMMON TRANSPORT CHANNEL TYPE NOT SUPPORTED

The concerned cell(s) do not support the RACH and/or FACH and/or CPCH Common Transport Channel Type.

16326 PRIORITY TRANSPORT CHANNEL ESTABLISHED

The CRNC cannot perform the requested blocking because a transport channel with a high priority is present.

16327 MEASUREMENT NOT SUPPORTED FOR THE OBJECT

At least one of the concerned cell(s) does not support the requested measurement on the concerned object type.

16328 MEASUREMENT TEMPORARILY NOT AVAILABLE

The Node B can temporarily not provide the requested measurement value.

16329 UNKNOWN LOCAL CELL ID

The Node B is not aware of a local cell with the provided Local Cell ID.

16330 S-CPICH NOT SUPPORTED

The concerned cell(s) do not support S-CPICH.

16331 SIB ORIGINATION IN NODE B NOT SUPPORTED

Page 442: DX Error Messages

442 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The Node B does not support the origination of the requested SIB for the concerned cell.

16332 COMBINING RESOURCES NOT AVAILABLE

The value of the received Diversity Control Field IE was set to "Must", but the Node B cannot perform the requested combining.

16333 NUMBER OF DL CODES NOT SUPPORTED

The concerned cell(s) do not support the requested number of DL codes.

16334 NUMBER OF UL CODES NOT SUPPORTED

The concerned cell(s) do not support the requested number of UL codes.

16335 DEDICATED TRANSPORT CHANNEL TYPE NOT SUPPORTED

The concerned cell(s) do not support the Dedicated Transport Channel Type.

16336 CM NOT SUPPORTED

The concerned cell(s) do not support Compressed Mode.

16337 DPC MODE CHANGE NOT SUPPORTED

The concerned cells do not support DPC mode changes.

16338 INFORMATION TEMPORARILY NOT AVAILABLE

The requested information can temporarily not be provided.

16339 INFORMATION PROVISION NOT SUPPORTED FOR THE OBJECT

The requested information provision is not supported for the concerned object types.

16340 REQUESTED CONFIGURATION NOT SUPPORTED

The concerned cell(s) do not support the requested configuration i.e. power levels, Transport Formats, physical channel parameters.

16341 NETWORK ELEMENT GROUP ID DOES NOT EXIST

Network element group id does not exist.

16342 TRANSMISSION EQUIPMENT ATTACHED TO NETWORK ELEMENT GROUP

Transmission equipment is attached to network element group.

16343 TRANSMISSION EQUIPMENT SOFTWARE BUILD MASTER FILE NOT FOUND

Transmission equipment software build master file not found.

16344 TRANSMISSION EQUIPMENT SOFTWARE MODULE FILE NOT FOUND

Transmission equipment software module file not found.

16345 TRANSMISSION EQUIPMENT SOFTWARE MODULE FILE SIZE INCORRECT

Transmission equipment software module file size is incorrect.

16346 TRANSMISSION EQUIPMENT MASTER FILE FILENAME IS INCOR-RECT

Page 443: DX Error Messages

DN987378Issue 24-0

443

General Error Messages of System DX error messages

Id:0900d8058077e097

Transmission equipment master file filename is incorrect.

16347 TRANSMISSION EQUIPMENT SOFTWARE BUILD FROM DISK DELETION FAILED

Transmission equipment software build deletion from disk failed.

16348 SOFTWARE BUILD IS ATTACHED TO NETWORK ELEMENT GROUP

Software build is attached to network element group.

16349 TRANSMISSION EQUIPMENT HAS OPEN REMOTE SERVICE TERMINAL SESSION

Transmission equipment has open remote service terminal session.

16350 SUBDIRECTORY IS USED BY OTHER SOFTWARE BUILD

Subdirectory is used by other software build.

16351 TRANSMISSION EQUIPMENT IS ATTACHED TO SOFTWARE DOWNLOAD

Transmission equipment is attached to software download.

16352 FRAME PROTOCOL DL SYNCHRONIZATION FAILURE

Frame protocol has lost synchronisation in downlink direction.

16353 OCNS MAY NOT BE ENABLED IN WCEL CREATION

Parameter "OCNSEnabled" may not be set to value "yes" when WCEL is created.

16354 OCNS MAY BE ACTIVATED ONLY WHEN WCEL STATE IS "WORK-ING"

Parameter "OCNSEnabled" may be set to value "yes" only when WCEL state is "working".

16355 WCEL MAY NOT BE LOCKED IF OCNS IS ACTIVE

WCEL state may not be changed to locked if parameter OCNSEnabled has value "yes".

16356 RECORD NOT FOUND

The specified record does not exist.

16357 INDEX OF RECORD IS OUT OF RANGE

The specified index is out of range.

16358 INVALID OVERLOAD CONTROL PARAMETER

The specified parameters are invalid.

16359 RECORD TO BE CREATED ALREADY EXISTS

A record with the same content already exists.

16360 CELL DOES NOT EXIST IN BTS

Cell does not exist in BTS.

16361 ISNCCR FEATURE IS NOT IN USE IN BSC

ISNCCR (Inter System Network Controlled Cell Re-Selection) feature is not supported in the BSC.

Page 444: DX Error Messages

444 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16362 MAXIMUM NUMBER OF LICENCES FOR FOREIGN GADGETS EXCEEDED

Maximum number of licences for foreign gadgets exceeded.

16363 TELNET SESSION TO LAN DEVICE IS OPEN BY ANOTHER USER. TRY AGAIN LATER.

Telnet session to LAN device is already open by another user. Only one telnet session can be open to the LAN device at the same moment.

16364 COMMAND IS NOT POSSIBLE IN THIS CONFIGURATION

The command given cannot be executed in the current configuration.

16365 PASSWORD HISTORY CHECKING FAILED

The new password can be found in the password history of the user, or it has been changed too recently.

16366 PASSWORD NOT COMPLIANT WITH POLICY

The new password does not comply with the used password policy.

16367 EMERGENCY CALL ONGOING

Datamanager prevents some action because there is an ongoing emer-gency call.

16368 GPRS ENABLED TRX NOT ATTACHED TO DYNAMIC ABIS POOL IN CS3&CS4 BTS

GPRS ENABLED TRX NOT ATTACHED TO DYNAMIC ABIS POOL IN CS3&CS4 BTS

16369 GPRS ENABLED BCCH TRX NOT ATTACHED TO DYNAMIC ABIS POOL IN CS3&CS4 BTS

GPRS-enabled BCCH TRX not attached to dynamic ABIS pool in CS3&CS4 BTS.

16370 COST OBJECT NOT FOUND

COCO state object not found in the radio network database.

16371 PASSWORD POLICY NOT FOUND

A password policy with the requested index does not exist.

16372 PCCCH CONNECT TIMER HAS EXPIRED

RCOPRB has not acknowledged the PCCCH connect request.

16373 PCCCH INFO TIMER HAS EXPIRED

ABIPRB has not acknowledged the PCCCH connect request.

16374 PASSWORD POLICY IS IN USE

The password policy that is going to be deleted is still in use.

16375 PASSWORD POLICY FEATURE NOT ACTIVE

The Password Policy feature is not activated.

16376 ATM LOGICAL RESOURCE IS BUSY, TRY LATER

The system cannot handle a configuration operation because it is busy cleaning up or creating ATM LOGICAL RESOURCE.

16377 FREQUENCY OF CELLS BCCH TRX IS NOT ALLOWED TO BE IN CELLS DFCA MA LIST

Page 445: DX Error Messages

DN987378Issue 24-0

445

General Error Messages of System DX error messages

Id:0900d8058077e097

BCCH frequency of the cell may not be used in DFCA MA list of the cell.

16378 FREQUENCY OF CELLS BCCH TRX NOT ALLOWED TO BE IN CELLS UNSYNCHRONIZED MODE DFCA MA LIST

BCCH frequency of the cell is not allowed to use in DFCA unsynchro-nised mode MA list of the cell.

16379 DFCA HOPPING AND BB HOPPING MAY NOT BE USED IN A BTS AT THE SAME TIME

DFCA Hopping cannot be used simultaneously with BB hopping in a BTS.

16380 IT IS NOT ALLOWED TO USE BOTH EGSM AND PGSM FREQUEN-CIES IN A BTS

EGSM900 and PGSM900 frequencies must not be used at the same time in a BTS.

16381 ADMINISTRATIVE STATE OF DFCA HOP BTS OR DFCA TRXS OF UNLOCKED DFCA HOP BTS NOT LOCKED

Administrative state of DFCA Hopping BTS is not locked or administra-tive states of DFCA TRXs in unlocked DFCA BTS are not locked.

16382 DFCA MODE OF THE BTS MUST BE STANDBY BEFORE DFCA HOPPING

DFCA mode of the BTS must be STANDBY before DFCA hopping.

16383 ACTIVITY STATE OF BOTH DFCA MA LIST A AND B CANNOT BE IN USE SIMULTANEOUSLY

Activity state of both DFCA MA lists, A and B, cannot be used simulta-neously.

16384 FEATURE UTDOA AMR SUPPORT IS NOT INSTALLED OR NOT ACTIVE IN THE BSC

The UTDOA (Uplink Time Difference of Arrival) AMR (Adaptive Multi-rate Codec) SUPPORT feature is not supported in the BSC.

16385 CAPACITY LICENCE OF FEATURE GB OVER IP IS TRYING TO BE EXCEEDED

Creating more objects would exceed the capacity licence of the feature Gb over IP. The system will not allow the creation of more objects. Check the used capacity and the allowed capacity defined by the licence.

16386 BTS SOFTWARE DOES NOT SUPPORT CS3&CS4 FEATURE

BTS software does not support the CS3&CS4 feature.

16387 OPTION REVERSED HUNTING IS NOT IN USE IN BSC

The option REV HUNT (Reversed Hunting) error code is received when the option is not enabled but an attempt at managing measurement is being made.

16388 LOADING SOURCE NOT KNOWN EMB UNIT

BOLERO has tried to use a source unit that is not known by the EMB post office EPOFFI. The unit does not exist in the configuration, or it has not yet been registered with EPOFFI after the last restart.

Page 446: DX Error Messages

446 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16389 LAN INTERFACE STATE MANAGEMENT FILE IS CORRUPTED

The data of some Internal LAN interface state management related file has been corrupted.

16390 ASSIGNED NETWORK INTERFACE NOT CHANGED

The assigned network interface of the host unit has not been changed.

16391 PROPERTY OF NETWORK INTERFACE NOT CHANGED

The property of the network interface was not changed.

16392 NO SECONDARY INTERNAL LAN

No secondary operational Internal LAN found.

16393 LAN INTERFACE MANAGEMENT OPERATION NOT ALLOWED

The requested Internal LAN network interface change is not possible.

16394 IP ADDRESS IS IN USE. IP ADDRESS MUST BE REMOVED FROM SWITCH FIRST

The IP address is in use in the switch. Remove the IP address with a terminal console connection to the switch.

16395 SNMP OID TOO LONG

The used SNMP OID is too long.

16396 ILLEGAL ETHERNET DEVICE ID

The given ethernet device identifier is invalid. In other words, this ethernet interface does not exist.

16397 ILLEGAL ETHERNET INTERFACE CONFIGURATION

The request ethernet interface configuration is invalid.

16398 NO INTERFACE CONFIG POSSIBLE BECAUSE OF LOOP

The ethernet interface is in loop mode. No interface configuration is possible at the moment.

16399 ETHERNET CONFIG IS ALREADY SET

The given input ethernet configuration equals the current used one. There is no need to change the setup.

16400 CONGESTION CAUSED BY OVERLOAD PROTECTION

Resource reservation was not allowed by overload protection.

16401 RM3PRB HAS LIMITED THE UNIT SEARCH BECAUSE TOO HIGH CPU LOAD

RM3PRB did not made a complete search for capacity because of CPU overload in CACU/RSMU.

16402 RM3PRB CANNOT ALLOCATE SERVICE INTO GIVEN UNIT DUE TO MXU OVERLOAD

RM3PRB received a service request to place the service into the tribu-tary unit of MXU while MXU was overloaded and the given unit was set as the only option.

16403 RM3PRB CANNOT ALLOCATE SERVICE BECAUSE ALL MXU UNITS ARE OVERLOADED

Page 447: DX Error Messages

DN987378Issue 24-0

447

General Error Messages of System DX error messages

Id:0900d8058077e097

RM3PRB cannot allocate the requested service into any unit because all MXUs which have signal processing units as tributaries are over-loaded.

16404 OCNS CANNOT BE ACTIVATED BECAUSE CELL MAX POWER WOULD BE EXCEEDED

The OCNS feature cannot be activated in the cell because the cell maximum transmission power would be exceeded.

16405 OCNS FEATURE ACTIVATION WAS NOT SUCCESSFUL

OCNS feature activation was not successful.

16406 THE FUNCTIONALITY IS NOT IMPLEMENTED IN PCU

This error code can be returned if the PCU does not support a specific functionality.

16407 THE INTERNAL OLC RECORD TABLE OF OLJMAN (OLJMAN) IS FULL

The internal OLC record table of OLJMAN (OLJMAN) is full.

16408 SWITCHING UNIT IS PART OF LAN CONFIGURATION

The LAN switching unit is part of a LAN configuration.

16409 ALL PCU CARDS IN SAME TRACK OF BCSU SHOULD BE PCU2

All PCU cards in same track of BCSU should be PCU2.

16410 SUBSCRIBER GROUP NAME IS ILLEGAL

Illegal subscriber group name.

16411 AUTHORISED NETWORKS NAME IS ILLEGAL

Illegal authorised networks name.

16412 FAILURE ACCESSING A HARDWARE RESOURCE

Failure accessing a hardware resource.

16413 ILDATA DATABASE SEARCH COMPLETED

The search in the ILDATA database has come to an end and no more data can be found with the given search.

16414 ILLEGAL DATABASE PARAMETER VALUE USED

The parameter used in ILDATA database procedure was not legal and therefore the execution of the database procedure failed.

16415 ILLEGAL ILDATA SEARCH KEY COMBINATION USED

The search key combination that was used in ILDATA database query was not legal and therefore the query failed.

16416 INTERNAL ERROR IN ILDATA DATABASE PROCEDURE

An internal error occurred in the ILDATA database procedure and there-fore the procedure failed.

16417 LAN ALREADY EXISTS IN ILDATA DATABASE

The LAN already exists in the ILDATA database and therefore it cannot be created again in the ILDATA database.

16418 LAN DOES NOT EXIST IN ILDATA DATABASE

Page 448: DX Error Messages

448 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Either the LAN does not exist in the ILDATA database and therefore it cannot be removed from the database, or the query of the LAN-related data has failed because the LAN does not exist in the database.

16419 LAN ELEMENT ALREADY EXISTS IN ILDATA DATABASE

The LAN element already exists in the ILDATA database and therefore it cannot be created again in the database.

16420 LAN ELEMENT DOES NOT EXIST IN ILDATA DATABASE

Either the LAN element does not exist in the ILDATA database and therefore it cannot be removed from the database or the query of the LAN element related data has failed because the LAN element was not found in the ILDATA database.

16421 ETHERNET INTERFACE ALREADY EXISTS IN ILDATA DATABASE

The Ethernet interface already exists in the ILDATA database and therefore it cannot be created again in the database.

16422 ETHERNET INTERFACE DOES NOT EXIST IN ILDATA DATABASE

The Ethernet interface does not exist in the ILDATA database and therefore it cannot be removed from the database or the query of the Ethernet interface related data has failed because the Ethernet inter-face was not found in the ILDATA database.

16423 LINK ALREADY EXISTS IN ILDATA DATABASE

The link between the two Ethernet interfaces already exists in the ILDATA database and therefore it cannot be created again in the data-base.

16424 ETHERNET LINK DOES NOT EXIST IN ILDATA DATABASE

The link between two Ethernet interfaces does not exist in the ILDATA database and therefore it cannot be removed from the ILDATA database or the query of the link related data has failed, because the link was not found in the ILDATA database.

16425 SWITCH COMMAND FAILED BECAUSE HIGHER PRIORITY REQUEST IS ACTIVE

Switch command failed because higher priority request is active.

16426 FAR END DID NOT ACKNOWLEDGE THE GIVEN SWITCH COMMAND

Far end did not acknowledge the given protection switching command.

16427 EXERCISE CANNOT BE EXECUTED BECAUSE PROTECTION SECTION IS IN USE

The selector is in protection section and therefore the exercise command was not executed.

16428 SET ALREADY BELONGS TO A PROTECTION GROUP

One of the given SETs is already part of an existing protection group.

16429 THE OBJECT DOES NOT SUPPORT THE REQUESTED STATISTIC COUNTERS

The object does not support the requested statistic counters.

16430 SET IS INACTIVE

Page 449: DX Error Messages

DN987378Issue 24-0

449

General Error Messages of System DX error messages

Id:0900d8058077e097

Operation can not be done for the inactive SET

16431 PATHS OF ACTIVE AND INACTIVE SET WERE CONFIGURED

Path level configuration was done for both active and inactive SETs.

16432 RM3 CANNOT ALLOCATE THE SERVICE INTO GIVEN DESTINA-TION UNIT BECAUSE THE UNIT IS OVERLOADED

RM3 cannot allocate the service into the DMPG or TPG unit because the given unit is overloaded at the moment.

16433 INTERNAL LAN CONNECTION SUPERVISION FILE IS CORRUPTED

The data of some of the Internal LAN Connection Supervision files (ZYD*.XML) has been corrupted.

16434 INTERNAL LAN CONNECTION SUPERVISION HAS NOT INITIAL-IZED THE ILDATA DATABASE YET

Internal LAN Connection Supervision has not initialized the ILDATA database yet. The initialization has not been started or it is going on.

16435 DELETION OF INCOMING ADJACENCIES FAILED

RNW Plan Manager program block (RAYMAN, RNC OMU) has failed to automatically delete incoming adjacencies of a WCEL being deleted. WCEL deletion has succeeded but there may still exist adjacencies in the home RNC pointing to the deleted WCEL.

16436 OCNS FEATURE WAS NOT IN DISABLED STATE IN THE CELL WHEN THE OPERATION WAS PERFORMED

The OCNS feature was not in disabled state in the cell when the oper-ation was performed. In order to carry out the operation successfully, the state of the OCNS feature in the cell must be disabled.

16437 OCNS FEATURE ACTIVATION FAILED DUE TO BTS MALFUNCTION

OCNS feature activation did not succeed because there was a malfunc-tion in the BTS.

16438 INCORRECT ONCS FEATURE ACTIVATION MESSAGE DATA

The OCNS feature activation message data received from RAKTOR was incorrect.

16439 OCNS FEATURE WAS NOT IN ENABLED STATE IN THE CELL WHEN OPERATION WAS PERFORMED

The OCNS feature was not in enabled state in the cell when the opera-tion was performed. In order to perform the operation successfully, the state of the OCNS feature in the cell must be enabled.

16440 TELNET CLIENT IS ALREADY IN USE. ONLY ONE TELNET CON-NECTION IS ALLOWED AT THE SAME TIME

The telnet client is already in use. Only one telnet connection is allowed at the same time.

16441 PARAMETERS THAT BELONG ONLY TO UPLOAD PLAN DISCOV-ERED IN DOWNLOADED PLAN

RNW Plan Processor program block PABROS (in RNC OMU) has found parameters that belong only to RNW upload plan (actuals) in downloaded plan.

Page 450: DX Error Messages

450 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16442 CAPACITY USAGE REQUEST FAILED

Message sending to the used capacity service provider failed. The service provider registers itself to the Feature management. Feature management sends the request message when the used capacity level is needed.

16443 CAPACITY LEVEL USAGE REQUEST SERVICE PROVIDER NOT FOUND

The registered capacity usage level service provider for the feature code is not found or the capacity feature is not in use.

16444 THE GIVEN FEATURE CODE DOES NOT EXIST

The Feature code is not in use or it is not known by the error initiator.

16445 THERE IS NOT ENOUGH DPRAM IN THE ETGR FOR THE REQUESTED OPERATION

There is not enough DPRAM in the ETGR for the requested operation.

16446 AT THE MOMENT, THERE IS NOT ENOUGH NON-FRAGMENTED DPRAM IN THE ETGR

At the moment, there is not enough non-fragmented DPRAM in the ETGR for the requested operation.

16447 PLMN ID MUST BE SAME FOR CS AND PS CN (CORE NETWORK)

Same PLMN id must be defined for CS and PS CN (Core Network).

16448 SOFTWARE DOWNLOAD TO TRANSMISSION EQUIPMENT IS ONGOING

Software download to transmission equipment is ongoing.

16449 HMRESE ATTEMPTED TO POINT OVER ITS DIAGNOSTICS ARRAY SIZE

The HMRESE array, which is used to store HMS core configuration on the ppa level as bitmapped information for diagnostics use, has attempted to point over its size. The action has been prevented, but the stored configuration will not be correct. The cause is probably a network element configuration that is larger than what the HMRESE service is designed to handle.

16450 HMRESE HAS ATTEMPTED TO POINT OVER ITS EVENT ARRAY SIZE FOR DIAGNOSTICS

Array of HMRESE array which is used to store HMS core configuration related to different recovery events aimed to HMS transmission line for diagnostics use has attempted to point over its size. Action is prevented but stored configuration will not be correct.

16451 HMRESE HAS RECEIVED AN ILLEGAL BUFFER HANDLE

The buffer handle which HMRESE should use is illegal and therefore the buffer cannot be used.

16452 SOFT CHANNEL CAPACITY LICENCE EXCEEDED

The Soft Channel Capacity licence has been exceeded.

16453 AMOUNT OF SOFT CHANNELS IN BSC EXCEEDS AMR HR LICENCE CAPACITY

Page 451: DX Error Messages

DN987378Issue 24-0

451

General Error Messages of System DX error messages

Id:0900d8058077e097

Amount of Soft channels in BSC exceeds AMR HR licence capasity.

16454 PCU AND PCU2 CAPACITY LICENCE EXCEEDED

The PCU and PCU2 Capacity licence has been exceeded.

16455 INCORRECT VERSION OF HMRESE DATA STRUCTURE FOR DIAGNOSTICS USE HAS BEEN READ

The version of the data structure where certain information has been stored for use in diagnostics is incorrect. The information is stored in a memory area where it stays over a reset. This situation is possible in cases where the version of HMRESE has been changed. The contents of the data structure cannot be used, but this has an effect only if diag-nostics are running.

16456 UNKNOWN NBAP INTERFACE TYPE

Unknown NBAP interface type.

16457 WARMING OF DATA STRUCTURE FAILED

HMRESE on OMU have failed to warm up the data structure used by diagnostics.

16458 MAXIMUM NUMBER OF PLMN IDS FOR CBC (CELL BROADCAST CENTER) EXCEEDED

The maximum number of PLMN ids for CBC (Call Broadcast Center) has been exceeded. The optional feature IMSI based HO is not ON.

16459 ETHERNET INTERFACE AND LAN ARE ALREADY CONNECTED IN ILDATA DATABASE

The connection between Ethernet interface and LAN already exists in the ILDATA database and therefore it cannot be created again in the database.

16460 ETHERNET INTERFACE AND LAN ARE NOT CONNECTED IN ILDATA DATABASE

The connection between Ethernet interface and LAN does not exist in ILDATA database and therefore it cannot be removed from ILDATA database or the query of the data has failed, because the connection between Ethernet interface and LAN was not found in ILDATA data-base.

16461 MEMORY TEST OF A DSP HAS FAILED

Some errors have been found during the memory test of a DSP.

16462 SAME PLMN ID DEFINED FOR CBC (CELL BROADCAST CENTER) AND WCEL (SAB ACTIVATED)

It is not allowed to remove CBC or remove PLMN id of the CBC if same PLMN id defined for the WCEL with 3 SCCPCH (SAB activated).

16463 PASSWORD POLICY UNACCEPTABLE

The given password policy is not acceptable. For example, the total sum of required characters, digits and special characters may be greater than the maximum password length.

16464 INQUIRY OF INTERNAL LAN CONNECTIONS FAILED

Page 452: DX Error Messages

452 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Inquiry of internal LAN connections with parameters given by the user has failed.

16465 UPDATE OF SUPERVISION PARAMETERS FOR THE INTERNAL LAN CONNECTIONS FAILED

Update of supervision parameters for the internal LAN connections has failed.

16466 MAC ADDRESS OF ETHERNET INTERFACE IS ALREADY IN USE IN ILDATA DATABASE

The MAC address of the Ethernet interface is used by the Ethernet interface of another functional unit and therefore the Ethernet interface cannot be created in the ILDATA database or the MAC address of the Ethernet interface cannot be changed.

16467 RMDPRB HAS DETECTED THAT CPM OF THE UNIT IS OVER-LOADED. THUS THE REQUEST CANNOT BE SERVED

The amount of services consuming CPM processing capacity has reached the maximum level. No more services can be created on the unit until the overload situation has been bypassed.

16468 RMDPRB HAS DETECTED THAT CPU OF THE UNIT IS OVER-LOADED. THUS THE REQUEST CANNOT BE SERVED

The amount of services consuming CPU processing capacity has reached the maximum level. No more servides can be created on the unit until the overload situation has been bypassed.

16469 MESSAGE QUEUE OF RMDPRB IS OVERLOADED

There are too many messages in the message queue of RMDPRD. This is interpreted as an overload situation and RMDPRB has no time to process the old messages. Therefore no new services or modifications are allowed in the unit until the situation is back to normal.

16470 FEATURE COMMERCIAL UTDOA IS NOT INSTALLED OR NOT ACTIVE IN THE BSC

The Commercial UTDOA (Uplink Time Difference of Arrival) feature is not supported in BSC (Base Station Controller).

16471 MORE THAN ONE TYPE OF OVERLOAD IS CURRENTLY ON IN THE UNIT

RMDPRB cannot reply with an error code indicating a certain overload type while several overload types are occurring simultaneously.

16472 EDGE TRX CAPACITY LICENCE EXCEEDED

The EDGE TRX capacity licence is exceeded.

16473 CS3&CS4 TRX CAPACITY LICENCE EXCEEDED

The CS3&CS4 TRX capacity licence has been exceeded.

16474 RESERVED DSP SERVICE ID SPACE IS NOT SUFFICIENT

There are too many DSP services active at the same time. This is an RM3PRB-internal problem.

16475 DROP CALL BREAKDOWN FEATURE IS NOT IN USE IN BSC

Page 453: DX Error Messages

DN987378Issue 24-0

453

General Error Messages of System DX error messages

Id:0900d8058077e097

An observation error code is received when an attempt to manage observation has been made while the DCB (Drop Call Breakdown) feature is not enabled.

16476 REQUESTED POOL NAME DOES NOT EXIST

There is no DSP parameter pool with this name in LEKFIL.

16477 REQUESTED POOL ID DOES NOT EXIST

There is no DSP parameter pool with this ID in LEKFIL.

16478 POOL NAME TO BE CREATED ALREADY EXISTS

There is already a DSP parameter pool with this name in LEKFIL.

16479 POOL ID TO BE CREATED ALREADY EXISTS

There is already a pool with this ID in LEKFIL.

16480 REQUESTED POOL IS NOT ALLOWED TO BE MODIFIED

This DSP parameter pool cannot be modified because it includes default parameters.

16481 REQUESTED POOL MAY NOT BE DELETED

This DSP parameter pool cannot be deleted because it includes default parameters.

16482 NO ACKNOWLEDGE MESSAGE FROM RMDPRB

TG3CAL has sent a sprm_mod_note_s message to notify RMDPRB that the file has been changed, but RMDPRB does not acknowledge.

16483 A2SP LOAD IS ABOVE ACCEPTABLE LEVEL. CONNECTION CREATION NOT POSSIBLE UNTIL LOAD GOES LOW

A2SP is heavily loaded. No more connection creation or modification requests will be accepted until the load goes down below an acceptable level.

16484 PCU CONFIGURATION MISMATCH

GPRS/EGPRS configuration failed. All BCSUs do not have same amount of PCUs installed or there is a PCU type in at least one of the BCSUs that does not support the activated feature or there is a PCU type in at least one of the BCSUs that runs out of Abis channel connec-tivity capacity.

16485 BOLERO HAS BEEN COMMANDED TO FAULTY BUS

BOMBER has commanded BOLERO to use another bus and BOLERO has detected that bus to be faulty, at least the local interface of the bus does not work. According to the loading protocol definition BOLERO cannot change back to the original bus and loading will fail. This kind of situation can occur temporarily when functional states of buses do not represent actual functionality, i.e. the supervision of buses has not detected the fault yet or recovery actions of buses are banned.

16486 MODIFY REQUEST FAILED BECAUSE OF RESOURCE SHORTAGE IN DESTINATION UNIT

RM3PRB cannot modify the service because there are not enough resources left in the unit where the modified service is located.

16487 EQUIPMENT GENERATION IS NOT Q1E

Page 454: DX Error Messages

454 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Equipment generation is not Q1E.

16488 SOFTWARE BUILD IS ACTIVE BUILD IN NETWORK ELEMENT GROUP

Software build is active build in network element group.

16489 SGSN DOES NOT SUPPORT THE REQUESTED TYPE OF IP ENDPOINT

The size procedure in Dynamic Configuration has failed because SGSN does not support the requested type of IP Endpoint.

16490 TELNET SOCKET CREATION FAILED

Telnet socket creation failed.

16491 TFTP SOCKET CREATION FAILED

TFTP socket creation failed.

16492 COULD NOT CONNECT TO TELNET SERVER

Could not connect to Telnet server.

16494 TOO MANY INCOMING GSM NEIGHBOURS FOR THE CELL

The cell has been defined as outgoing adjacent cell for too many cells in this BSC.

16495 BTS SOFTWARE DOES NOT SUPPORT IBHO FEATURE

BTS site type or software version does not support IMSI based handover (IBHO) feature.

16496 IBHO FEATURE IS NOT IN USE IN BSC

The IBHO (IMSI-based handover) feature enables IMSI (Internal Mobile Subscriber Identity) based handovers in the BSC. The requested man-agement operation cannot be executed because feature IMSI based handover has not been activated in the BSC. Check also the licence status of this feature in the BSC.

16497 SOFT CHANNEL CAPACITY FEATURE IS NOT IN USE IN BSC

The Soft Channel Capacity feature is not in use in BSC.

16498 PCU LICENCE DOES NOT EXIST OR IS IN WRONG STATE

PCU licence does not exist or is in wrong state.

16499 LICENCE FILE FOUND IN DESTINATION DIRECTORY

The licence (XML) file was already found in the destination directory.

16500 SETTING THE FEATURE STATE FAILED

Setting of the state of the feature (that belongs to a licence) failed.

16501 DELETING LICENCE FILE FAILED

Deleting the (XML) licence file failed.

16502 COPYING LICENCE FILE FAILED

Copying the (XML) licence file failed.

16503 LICENCE HAS EXPIRED

The licence has expired.

Page 455: DX Error Messages

DN987378Issue 24-0

455

General Error Messages of System DX error messages

Id:0900d8058077e097

16504 INTERNAL NBAP ERROR PREVENTING PROCEDURE COMPLE-TION

One of the internal tables of NBAP needed for this procedure is full. This prevents NBAP from completing the procedure, because routing infor-mation cannot be stored.

16505 TFTP TRANSFER FAILED

TFTP transfer failed.

16506 RNW PARAMETER IS NO LONGER USED

RNW parameter is no longer used. RNW Plan Processor in RNC OMU has rejected the parameter.

16507 GIVEN PAPU DOES NOT BELONG TO THE SAME GROUP AS THE CELL

The given PAPU does not belong to the PAPU group to which the cell is configured in BSC.

16508 GBCPRB DID NOT RESPOND TO GPUPRB IN A GIVEN TIME

GBCPRB program block did not acknowledged to GPUPRB program block.

16509 DIGIT ANALYSIS FAILED

Digit analysis has failed.

16510 TEMPERATURE TOO HIGH

The temperature of the processor exceeds the maximum.

16511 TFD INTERNAL ERROR

TFDHCP internal error.

16512 BINDING ID REQUEST FAILED

Binding id request failed.

16513 BINDING ID RELEASE FAILED

Binding id release failed.

16514 IBHO TO GSM AND BA LIST USAGE FOR ACTIVE MOBILES IS NOT SIMULTANEOSLY ALLOWED IN CELL

The BCCH allocation frequency list for active MSs and IMSI based HO functionality cannot be used simultaneously in the same cell.

16515 SAME PLMN CODE MUST NOT BE USED BY SEVERAL AUTHO-RISED NETWORKS IN A SINGLE ANE

The same PLMN code must not be used by several authorised networks in a single ANE list.

16516 SW VERSION INQUIRY NOT ALLOWED FOR THIS SWITCH TYPE

SW version inquiry not allowed for this switch type because SW included is not handled by the Software configuration Management of the network element.

16517 CREATION OF AAL CONNECTION FAILED IN CIUDAD BECAUSE CORRESPONDING NCID DOES NOT EXIST

Page 456: DX Error Messages

456 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The creation of aal connection failed in ciudad because no correspond-ing ncid exists.

16518 PLMN ID DEFINED FOR THE CBC (CELL BROADCAST CENTER) NOT FOUND IN CORE NETWORK LIST

PLMN id defined for the CBC (Cell broadcast center) must be found in core network definitions.

16519 PLMN ID DEFINED FOR THE CBC (CELL BROADCAST CENTER) NOT FOUND IN CORE NETWORK DEFINITIONS

PLMN id defined for the CBC (Cell broadcast center) must be found in core network definitions.

16520 BACKGROUND INTERFERENCE MATRIX OF THE CELL IS EMPTY

The BSC has not collected in the cell the neighbouring cell C/I data that is necessary for the DFCA channel allocation algorithm.

16521 BACKGROUND INTERFERENCE MATRIX OF THE CELL CANNOT BE VERIFIED

The BSC cannot verify if the DFCA channel allocation algorithm has the necessary neighbouring cell C/I data collected for the cell, because the program block is not responding.

16522 ONE OR MORE PCM-TSLS RESERVED BETWEEN 25-31

Interface mode change from E1 to T1/JT1 is not possible, because there is one or more PCM-TSLs reserved between TSLs 25-31.

16523 FEATURE CONNECT BSC IS NOT INSTALLED OR NOT ACTIVE IN THE BSC

The Connect BSC (Base Station Controller) feature is not supported in the BSC.

16524 IU RESERVATION FAILED

Resource reservation of Iu has failed.

16525 SFU PORT NOT DEFINED FOR UNIT

SFU port is not defined for unit.

16526 ALP1 UNIT NOT FOUND FOR TRIBUTARY

ALP1 (MXU) unit is not found for tributary unit.

16527 LICENCE IS NOT VALID

Licence validation failed because the signature is invalid. This can happen e.g. if the licence is changed after signing.

16528 NO FREE CLUSTER ID FOR UNIT

Cannot allocate free cluster identifier for ALP1 unit.

16529 TRIBUTARY UNIT EXISTS FOR REMOVED ALP1 UNIT

An attempt is made to remove the last ALP1 unit in a cluster, but there still exist tributary unit(s) connected to this ALP1 unit.

16530 NO PQII CAPACITY FOR THE REQUESTED SERVICE

The requested service cannot be set up because of a PQII resource shortage.

Page 457: DX Error Messages

DN987378Issue 24-0

457

General Error Messages of System DX error messages

Id:0900d8058077e097

16531 NO DSP CAPACITY FOR THE REQUESTED SERVICE

The requested service cannot be set up because of a DSP resource shortage.

16532 WAM ID AND CCP ID DO NOT MATCH

WAM ID and CCP ID (communication control port ID) do not match.

16533 LIST INDEX OF DUMMY LIST IS TOO HIGH

This error code is generated when the returned list index is too high.

16534 MDC SERVICE DOES NOT EXIST FOR HSDPA DL LEG

Iub or IuPs leg should be reserved before HSDPA DL leg reservation.

16535 LICENCE CHANGE HAS NOT BEEN NOTIFIED

Licence management has not been able to deliver a notification of the change in the licence or feature data to the application. Thus the system cannot utilise the updated licence or feature information.

16536 TOO MANY HSDPA CONNECTIONS

The maximum amount of HSDPA AAL2 connections for the AAL2 path has been reached.

16537 DUMMY HSDPA RESERVATION ALREADY DONE

HSDPA dummy reservation was attempted for an AAL2 path where there already was one.

16538 ACTIVE LICENCE DELETION IS NOT ALLOWED

A request was made to delete the licence, but the deletion was not allowed because the licence was active.

16539 UNIT NOT PARENT

The unit is not parent unit in the hierarchy.

16540 PIU NAME MISMATCH

The given unit type and the plug-in unit type variant name received from the given plug-in unit type variant do not match.

16541 PIU TYPE NOT VALID

With the given plug-in unit type value, the child unit type is not unambig-uous.

16542 UNIT TYPE NOT VALID

The unit type is not valid.

16543 NOT VIRTUAL UNIT

The unit is not virtual unit in hierarchy.

16544 SAB OPTION IS NOT IN USE IN RNC

Cell Broadcast Centre definitions allowed only if Service Area Broad-cast optionality is in use in Radio Network Controller.

16545 GRADUAL CELL SHUTDOWN FAILED

Gradual cell shutdown has failed.

16546 HSDPA COMMON SERVICE DOES NOT EXIST

Page 458: DX Error Messages

458 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

HSDPA common service must be reserved before HSDPA dummy res-ervations.

16547 FMCI ID NOT DEFINED FOR THE WCEL

ADJI object can not be created/modified if RT and NRT FMCI id not defined for the WCEL.

16548 FMCG ID NOT DEFINED FOR THE WCEL

ADJG object cannot be created/modified if RT and NRT FMCG id not defined for the WCEL.

16549 ILLEGAL SECTOR ID FOR WCEL UNDER THIS WBTS

Two or more cells can belong to the same sector if the following param-eters are identical for these cells: PtxPrimaryCPICH, PtxTarget, PtxOff-set, PrxTarget, PrxOffset, MCC, MNC.

16550 DIRECTLY CONNECTED SWITCHES MISSING WHEN ADDING INDIRECTLY CONNECTED SWITCH

At least one SWU with even index must be added to a LAN that is directly connected to a supervising unit before it is possible to add a SWU with even index to a LAN which is indirectly connected to the supervising unit. The same rule is also valid for odd indexes.

16551 LICENCE WAS INSTALLED BUT NOT ACTIVATED

The given licence was installed but not activated, because the start date of the licence is in the future.

16552 LICENCE CODE ATTRIBUTE ERROR IN XML LICENCE

The required licence XML file attribute licenceCode has an illegal value or it does not exist.

16553 LICENCE NAME ATTRIBUTE ERROR IN LICENCE

The required licence XML file attribute licenceName has an illegal value or it does not exist.

16554 ORDER ID ATTRIBUTE ERROR IN LICENCE

Required licence xml file attribute orderId has illegal value or it does not exist.

16555 SERIAL NUMBER ATTRIBUTE ERROR IN LICENCE

The required licence XML file attribute serialNbr has an illegal value or it does not exist.

16556 CUSTOMER NAME ATTRIBUTE ERROR IN LICENCE

The required licence XML file attribute customerName has an illegal value or does not exist.

16557 CUSTOMER ID ATTRIBUTE ERROR IN LICENCE

Required licence xml file attribute customerId has illegal value or it does not exist.

16558 START TIME ATTRIBUTE ERROR IN LICENCE

The required licence XML file attribute startTime has an illegal value or does not exist.

16559 FEATURE CODE ATTRIBUTE ERROR IN LICENCE

Page 459: DX Error Messages

DN987378Issue 24-0

459

General Error Messages of System DX error messages

Id:0900d8058077e097

The required licence XML file attribute featureCode has an illegal value or does not exist.

16560 LICENCE FILE DOES NOT HAVE RIGHT TARGET ID

The required licence XML file attribute targetId does not have the right value.

16561 LICENCE RECORD NOT FOUND IN MEMORY FILE

No licence record with the given search criteria was found in the LIK001 memory file.

16562 FEATURE RECORD NOT FOUND IN MEMORY FILE

No feature record with the given search criteria was found in the LIK002 memory file.

16563 FEATURE NAME NOT FOUND IN MEMORY FILE

No feature name with the given feature number was found in the LIK003 memory file.

16564 LICENCE RECORD ALREADY DELETED FROM MEMORY FILE

A licence record with the given search criteria has already been deleted from the LIK001 memory file.

16565 FEATURE RECORD ALREADY DELETED FROM MEMORY FILE

The feature record with the given search criteria has already been deleted from the LIK002 memory file.

16566 CORRUPTED LICENCE RECORD FOUND IN MEMORY FILE

A corrupted licence record was fourd in the LIK001 memory file. The content of the record does not match its HMAC checksum.

16567 CORRUPTED FEATURE RECORD FOUND IN MEMORY FILE

A corrupted feature record was found in the LIK002 memory file. The content of the recond does not match with its HMAC checksum.

16568 PARSING OF XML LICENCE FILE HAS FAILED

Parsing of XML licence file has failed.

16569 FEATURE STATE CHANGE TO ON STATE NOT ALLOWED BECAUSE LICENCE IS NOT ACTIVE

Feature state change not allowed to ON state because licence is not active. Only the features of an active licence can be set to ON state.

16570 LICENCE INSTALLATION FAILED BECAUSE THE SAME FEATURE CANNOT EXIST IN MULTIPLE LICENCES

Licence installation has failed because one or more features were found in some already installed licence. Each feature can only exist in one licence.

16571 LICENCE XML FILE NAME IS TOO LONG

The name of the licence XML file is too long. Therefore the licence cannot be installed.

16572 PLCG ALREADY CREATED

The Plcg (PLCG) object with the given identity has already been created in the radio network database.

Page 460: DX Error Messages

460 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16573 PLCG COLLECTION FULL

There is no room for a new Plcg (PLCG) object in radio network data-base.

16574 PLCG NOT FOUND

The Plcg (PLCG) object cannot be found in the radio network database.

16575 MAXIMUM OF LCELS UNDER PLCG

There is no room for a new Lcel (LCEL) under this Power Local Cell Group (PLCG).

16576 MAXIMUM OF PLCGS UNDER WBTS

There is no room for a new Plcg (PLCG) under this Base Station (WBTS).

16577 ICSU UNIT WITH SPECIFIED INDEX WAS NOT FOUND

ICSU unit with specified index is not found.

16578 GIVEN INDICES ARE NOT FREE

Given functional unit indices are not free.

16579 UNIT IS NOT THE UPPERMOST UNIT IN HIERARCHY

Given unit is not the uppermost unit in hierarchy.

16580 BASE KEY IS INVALID.

The base key cannot be used because it has been changed. Possibly the key is corrupt or has been changed in an uncontrolled way.

16581 CIRCUIT IN INCORRECT STATE. STATE OF THE CIRCUIT(S) PREVENTS THE REQUESTED OPERATION.

The requested operation cannot be executed because the state of the circuit(s) prevents it.

16582 STATE OF THE CIRCUIT(S) PREVENTS THE REQUESTED OPERA-TION. CHANGE THE STATE FIRST TO NU-US.

State of the circuit(s) prevents the requested operation. Change the state first to NU-US.

16583 LICENCE CAPACITY EXCEEDED

Licence capacity has been exceeded.

16584 INVALID LICENSE/FEATURE STATE

Invalid license/feature state.

16585 LOCAL USER ACCOUNT IS LOCKED.

The local user account has been locked and therefore cannot be used for login.

16586 USER ACCOUNT POLICY FEATURE NOT ACTIVE

The User Account Policy feature is not activated.

16587 UNIT INDICES CANNOT BE SOLVED.

The unit indices cannot be solved with the given parameter values.

16588 PLCG OBJECT IS NOT ALLOWED TO BE DELETED IF RELATION TO LCEL OBJECT EXISTS

Page 461: DX Error Messages

DN987378Issue 24-0

461

General Error Messages of System DX error messages

Id:0900d8058077e097

PLCG object is not allowed to be deleted if relation to LCEL object exists.

16589 ENABLING THE HSDPA FOR THE WCEL NOT ALLOWED BECAUSE HSDPA OPTIONALITY NOT SUPPORTED

It is not allowed to enable the HSDPA for the WCEL because HSDPA optionality is not supported.

16590 HSDPA FMCS MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

HSDPA FMCS must be defined if HSDPA enabled for the WCEL.

16591 HSDPA HOPS MUST BE DEFINED FOR OUTGOING ADJS OF THE WCEL

HSDPA HOPS must be defined for the outgoing ADJS of the WCEL.

16592 HSDPA FMCI MUST BE DEFINED IF HSDPA ENABLED AND ADJI(S) CREATED UNDER THE WCEL

HSDPA FMCI must be defined if HSDPA enabled and ADJI(s) created under the WCEL.

16593 HSDPA FMCG MUST BE DEFINED IF HSDPA ENABLED AND ADJG(S) CREATED UNDER THE WCEL

HSDPA FMCG must be defined if HSDPA enabled and ADJG(s) created under the WCEL.

16594 HSDPA HOPS MUST BE DEFINED IF HSDPA ENABLED FOR THE SOURCE WCEL

HSDPA HOPS must be defined for the ADJS if HSDPA enabled for the source WCEL.

16595 NO ANSWER RECEIVED FROM NRM IN TIME

The timer for waiting for an answer from NRM has expired, but no answer has been received.

16596 LOGIN DELAY IS SET

Delay between unsuccessful login attempts is set. The next login attempt cannot be made before the delay has elapsed.

16597 DTM FEATURE IS NOT IN USE IN BSC

The DTM feature is not enabled in BSC. Either the feature licence is not valid or the feature status is in disabled state.

16598 MULTIPOINT GB FEATURE IS NOT IN USE IN BSC

The Multipoint Gb feature is not enabled in BSC. Either the feature license is not valid, or the feature status is in disabled state.

16599 MAXIMUM NUMBER OF NRI IN NSE EXCEEDED

Maximum number of NRI in NSE exceeded.

16600 DATA TRANSMISSION OF LAST NSE OF PCU CANNOT BE PRE-VENTED

SGSN data transmission cannot be prevented if this NSE is the last non-prevented NSE in PCU.

16601 MAXIMUM NUMBER OF NSE IN PCU EXCEEDED

Page 462: DX Error Messages

462 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The maximum number of NSE in PCU has been exceeded.

16602 NO RECORDS FOUND WITH GIVEN PSEI IN PSE OBJECT COLLEC-TION

No records were found with the given network service entity identifier in the PSE object collection.

16603 PSEI ALREADY EXISTS

PSEI is already in use in another PSE.

16604 DEFAULT NSE CANNOT BE MODIFIED.

Multipoint Gb license state is CONF. The default NSE is not the last one in PCU, and attempt is made to delete it, or to prevent the default NSE.

16605 PCU2 LICENCE DOES NOT EXIST OR IT IS IN WRONG STATE

The PCU2 license either does not exist, or it is in the wrong state.

16606 NRI IS ALREADY DEFINED IN THE PSE

NRI is already defined in the PSE.

16607 PSE OBJECT CANNOT BE MODIFIED.

The PSE object cannot be modified.

16608 NRI DOES NOT EXIST

NRI does not exist.

16609 BCCH AND BSIC MUST BE DIFFERENT BETWEEN SEPARATE ADJG DEFINITIONS

Two or more neighbouring GSM cells have the same BCCH Frequency and BSIC identification. It is not allowed to create such ADJG definitions in RNC_RNW_DATABASE.

16610 EXTENDED CELL TRX NOT ALLOWED TO EXIST IN USED SITE TYPE

Extended cell TRX is not allowed to exist in used site type BTS.

16611 FLEXI EDGE TRX CAPACITY LICENCE EXCEEDED

Flexi Edge TRX capacity licence exceeded.

16612 FLEXI EDGE TRX LICENCE NOT IN USE IN BSC

Flexi Edge TRX licence not in use in BSC.

16613 COMBINED O&M AND TELECOM SIGNALLING NOT ALLOWED FOR USED SITE TYPE

Combined O&M and telecom signaling is not allowed to exist in used site type BTS.

16614 NO ANSWER RECEIVED FROM NBA IN TIME

Timer for waiting an answer from NBA has expired, and no answer has been received.

16615 MEASUREMENT OUT OF LIMITS FOR AAL2 STATISTICS

The number of AAL2 paths being measured exceeds the allowed number of measurements per MXU.

16616 TPI FOR AAL2 STATISTICS MEASUREMENT DOES NOT EXIST

Page 463: DX Error Messages

DN987378Issue 24-0

463

General Error Messages of System DX error messages

Id:0900d8058077e097

No internal NCID TPI corresponding to this AAL2 path exists in the CAC data structure.

16617 GIVEN ET AUDIO INTERFACE DEFINITION OF TCS ISSI IS ALREADY DEFINED IN DATABASE

The given ET audio interface definition of TCS ISSI is already defined in the database.

16618 VLAN ALREADY EXISTS

VLAN cannot be created, since it already exists.

16619 ILLEGAL VLAN ID

Illegal value in VLAN ID.

16620 NO TRAPHOST FOUND

Traphost was not found in the target switch.

16621 ERROR IN MULTILIST HANDLING

An error occurred during multilist handling.

16622 NO RESPONSE FROM PCU

PCU1/PCU2 did not respond in time.

16623 RESULT FILE ERROR

Error in reading result file.

16624 INTERNAL ERROR IN RRC-S

Scheduling of SIBs has failed, or some other internal error has occurred.

16625 PCU2 POOLING FEATURE IS NOT IN USE IN BSC

The creating of a new PSE or the addition of PCU to PSE has failed because the feature licence is invalid.

16626 GIVEN PCU IS IN USE IN SOME OTHER PSE. (SEVERAL PCUS UNDER PSE.)

The addition of Gb IP PCU to PSE has failed because the PCU is already in use in another PSE.

16627 THERE ARE TOO MANY PCUS IN ONE PSE

Creating PCU to PSE has failed because there already are 50 PCUs in this PSE

16628 DATA TRANSFER IN INTER PCU CELL RESELECTION IS DISABLED

The creation of a new PCP or addition of PCU to PCP has failed because BSC-level parameter Data Transfer in Inter PCU State is dis-abled.

16629 DYNAMIC ABIS POOL IS ATTACHED IN INCORRECT PSE

GPRS could not be enabled in the segment by defining PSEI in the segment, because a TRX in the segment is attached to DAP and DAP is not attached to this PSE.

16630 THERE ARE DAP(S) IN SOME PCU OF PSE

Page 464: DX Error Messages

464 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

PSE could not be deleted because there still are DAP(s) attached to the PCU of PSE.

16631 PSE OBJECT NOT FOUND WITH GIVEN PSEI

Deleting PSE or outputting PSE information or adding/removing PCU to/from PSE has failed because the PSE object with given PSEI does not exist.

16632 NS-VL NOT FOUND WITH GIVEN NS-VLI

Deleting PSE or removing PCU from PSE has failed because the NS-VL object with the given NS-VLI does not exist.

16633 THERE IS NO SPACE IN PCUS OF PSE FOR NEW DAPS OR CELLS

Removing PCU from PSE has failed because there is not enough space to move DAPs and SEGs to another PCU in PSE.

16634 DELETION OF THE LAST NS-VL OF NSE USED BY GPRS-ENABLED BTS IS NOT POSSIBLE

NS-VL could not be deleted because it is the last NS-VL in NSE and there still are cells using this NS-VL.

16635 SHAREDHSDPAALLOCATION GREATER THAN SHAREDHSDPA-FLOWCONTROLALLOCATION

SharedHSDPAFlowControlAllocation should be greater than or equal to the value of SharedHSDPAallocation in the same WBTS.

16636 HSDPAINITIALBITRATEUL MUST BE GREATER THAN OR EQUAL TO HSDPAMINALLOWEDBITRATEUL

HSDPAinitialBitrateUL must be greater than or equal to HSDPAminAl-lowedBitrateUL.

16637 INVALID LICENCE STATE

Licence state is invalid.

16638 PS LOAD REPORT DISTRIBUTION LIST NOT UPDATED

PS load report distribution list not updated to PCU2

16639 PCU2 POOLING FEATURE IS IN USE IN THE BSC

The PCU2 Pooling feature is in use in the BSC.

16640 DATA TRANSFER IN INTER PCU CELL RESELECTION SPECIFIC INFORMATION NOT UPDATED

Data transfer in inter PCU cell reselection specific information not updated to PCU2.

16641 PCU IP ADDRESSES NOT CONFIGURED

PCU IP addresses are not configured in PCU2.

16642 BEARER RE-ARRANGEMENT NEEDED

The Node B cannot perform the requested Radio Link Reconfiguration without bearer re-arrangement.

16643 CELL NOT AVAILABLE

The concerned cell or local cell is not available.

16644 DELAYED ACTIVATION NOT SUPPORTED

Page 465: DX Error Messages

DN987378Issue 24-0

465

General Error Messages of System DX error messages

Id:0900d8058077e097

The concerned cell(s) do not support delayed activation of RLs.

16645 POWER BALANCING STATUS NOT COMPATIBLE

The power balancing status in the SRNC is not compatible with that of the Node B.

16646 RL TIMING ADJUSTMENT NOT SUPPORTED

The concerned cell(s) do not support adjustments of the RL timing.

16647 REQUESTED TYPE OF BEARER RE-ARRANGEMENT NOT SUP-PORTED.

The Node B does not support the requested type of bearer re-arrange-ment.

16648 SIGNALLING BEARER RE-ARRANGEMENT NOT SUPPORTED

The Node B does not support the Signalling bearer re-arrangement.

16649 NODE B RESOURCES UNAVAILABLE

The Node B does not have sufficient resources available.

16650 REQUESTED TX DIVERSITY MODE NOT SUPPORTED

The concerned cell(s) do not support the requested transmit diversity mode.

16651 RADIO NETWORK CAUSE UNSPECIFIED

Sent when none of the other RNW cause values apply but the cause is still related to the Radio Network layer.

16652 DL SHARED CHANNEL TYPE NOT SUPPORTED

The concerned cell(s) do not support the Downlink Shared Channel Type.

16653 TX DIVERSITY NO LONGER SUPPORTED

Tx diversity can no longer be supported in the concerned cell.

16654 TRANSPORT LAYER CAUSE UNSPECIFIED

Sent when none of the other Transport Layer cause values applies but still the cause is related to the Transport Network layer.

16655 MISCELLANEOUS IUB CAUSE UNSPECIFIED

Sent when none of the other misc iub cause values applies and the cause is not related to any of the categories Radio Network Layer, Transport Network Layer, or Protocol.

16656 NO RESPONSE FROM HMS SLAVE NODE

No answer from HMILIB within 2 seconds when application SW called the routines in the library.

16657 REMOTE IP ENDPOINT IS ALREADY DEFINED IN THIS NSE

Remote IP/DNS name and remote UDP pair is already used in a NS-VL in this NSE.

16658 PARAMETER PTX_TARGET_HSDPA MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

Parameter PTX_TARGET_HSDPA must be given if HSDPA is enabled for the WCEL.

Page 466: DX Error Messages

466 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16659 PARAMETER PTX_MAX_HSDPA MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

Parameter PTX_MAX_HSDPA must be given if HSDPA is enabled for the WCEL.

16660 PARAMETER PTX_OFFSET_HSDPA MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

The parameter PTX_OFFSET_HSDPA must be given if HSDPA is enabled for the WCEL.

16661 PS CN ID MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

PS CN id must be given if HSDPA is enabled for the WCEL.

16662 TOO MANY DXTS IN NETWORK

The allowed number of DXTs in the network has been exceeded.

16663 TOO MANY DXTS IN SUBNET

The allowed number of DXTs in the subnet has been exceeded.

16664 NOT IN BASIC PACKET DATA MODE

Packet data should be in basic mode, but another mode was detected.

16665 GIVEN NSE IS DEFINED IN SOME PSE.

GPRS enabling has failed because the given NSEI is already defined under some PSE.

16666 NO SUITABLE PCU FOUND FOR CELL IN PSE

GPRS enabling has failed because there are no suitable PCUs in PSE.

16667 GIVEN PCU IS USED BY SAME PSE

PCU of DAP could not be changed because the given PCU exists in the same PSE as an old PCU.

16668 UPDATING OF THE NACC BOOK OF COMMISSIONS FAILED

NAKPRB or PCU2 has failed to update NACC BOOK OF COMMIS-SIONS table.

16669 READING OF THE NACC BOOK OF COMMISSIONS FAILED

PCU2 has sent a request to NAKPRB to download NACC BOOK OF COMMISSIONS, but NAKPRB cannot read NBOC.

16670 UPDATING OF ADJACENT CELLS IBNACC STATE FAILED

PCU2 has sent a request to PUBDAT to update the IBNACC state of adjacent cells, but the update failed.

16671 RIM MESSAGES ARE NOT SUPPORTED IN PCU

If in activating IBNACC feature when PUBDAT sends the message pcu_bsc_params_rnwdb_s to PCU2 and PCU2 has no signaling BVCs connected to SGSN, which supports RIM messaging, PCU2 replies to PUBDAT with this error code.

16672 PSEI PARAMETER GIVEN WITHOUT GPRS ENABLED PARAME-TER

The PSEI parameter could not be defined for the cell because the cell is not GPRS enabled.

Page 467: DX Error Messages

DN987378Issue 24-0

467

General Error Messages of System DX error messages

Id:0900d8058077e097

16673 RMDPRB HAS ENCOUNTERED PROBLEM WITH SERVER TYPE SERVICE (HS-DSCH)

Examples for server-type service problems are: a server is released right after creation; it is released before an ATM channel is connected to it; an ATM channel instance is released right after creation.

16674 TERMINATION WAS NOT READY FOR TOPOLOGY REQUEST

SPRM(D) rejected topology request because one of the terminations was not ready to be connected.

16675 MULTIPOINT A FEATURE IS NOT IN USE IN BSC

The Multipoint A interface feature is not enabled in BSC (Base Station Controller). Either the feature status is not valid or the feature is in disabled state.

16676 ATTEMPTED TO ADD TOO MANY CONNECTIONS TO A DSP SERVICE

SPRM(D) rejected a request to connect two DSP services to each other because one or both of them already have the maximum supported amount of connections.

16677 SAIC FEATURE IS NOT IN USE IN BSC

Single Antenna Interference Cancellation is not enabled in BSC (Base Station Controller).

16678 LBNCCR FEATURE IS NOT IN USE IN BSC

The Lb NCCR (Load Balancing with Network Controlled Cell Re-selec-tion) feature is not enabled in BSC (Base Station Controller).

16679 SMLC CAPACITY FEATURE IS NOT IN USE IN BSC

The SMLC (Serving Mobile Location Centre) Capacity feature is not enabled in BSC (Base Station Controller).

16680 SWITCH TYPE MISMATCH IN DHCP

This error code is used if the DHCP message switch type field conflicts with topology information.

16681 ICMP ECHO REQUEST PARTLY OK

Part of the ICMP echo requests were successful.

16682 INVALID LAN INTERFACE NAME

The LAN interface name is illegal.

16683 ILLEGAL LAN INTERFACE NUMBER

LAN port interface number is illegal.

16684 MAXIMUM NUMBER OF HSDPA-ENABLED WCELS IN BTS EXCEEDED

The maximum number of HSDPA-enabled WCELs in BTS has been exceeded.

16685 MAXIMUM NUMBER OF HSDPA WBTSS EXCEEDED

The maximum number of WBTSs that has HSDPA enabled WCELs exceeded.

16686 NSE RESET IS NOT ALLOWED

Page 468: DX Error Messages

468 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

A single NSE reset is not possible if the NSE belongs to a PSE where there are other NSE(s), the EQoS features license state is ON, and the PFC mode of all NSEs in the PSE is False.

16687 CONFLICT IN SWITCH PURPOSE IN TOPOLOGY AND LAN TYPE

The switch LAN unit type is not suitable for the switch purpose marked in the topology data.

16688 PCUPCM RESOURCE ALLOCATION CONFLICT

PCU has tried to allocate PCUPCM resources for the packet traffic channel from the EDAP area.

16689 EDAP NOT READY

PCU cannot accept packet channel activation before it has received information about EDAP configuration and of all EDAPs it is using.

16691 NO FREE DSP RESOURCES IN PCU

The PCU cannot accept packet channel activation because it has no free PCUDSP resources.

16692 NO FREE PCUPCM RESOURCES IN PCU

PCU cannot accept packet channel activation because it has no free PCUPCM resources.

16693 FILE LOADING SOURCE HAS NOT BEEN CHECKED

The proposed file loading source has not been checked by the loading issuer.

16694 FILE LOADING HAS FAILED FROM CURRENT SOURCE

File loading from the current file loading source has failed. Other file loading sources are still available to retry loading.

16695 STARTING UNIT WAS RESTARTED BECAUSE OF RESTART OF ACTIVE CODE LOADING SOURCE

The starting unit was restarted because the unit acting as a code loading source was restarted.

16696 STARTING UNIT WAS RESTARTED BECAUSE OF RESTART OF ACTIVE FILE LOADING SOURCE

Starting unit was restarted bacause the unit acting as a file loading source was restarted.

16697 WARM-UP TERMINATED BECAUSE OF RESTART OF ACTIVE WARM-UP SOURCE

Unit warm-up was terminated because the active warm-up source was restarted.

16698 WARM-UP TERMINATED BECAUSE OF RESTART OF WARM-UP CLIENT

Unit warm-up was terminated because the warm-up client was restarted.

16699 CODE LOADING HAS TERMINATED IN FAILURE

The starting unit has reported that the executing of code loading has ter-minated in failure.

Page 469: DX Error Messages

DN987378Issue 24-0

469

General Error Messages of System DX error messages

Id:0900d8058077e097

16700 FILE LOADING HAS TERMINATED IN FAILURE

The starting unit has reported that the executing of file loading has ter-minated in failure.

16701 EXECUTION OF UNIT RESTART PHASE 1 HAS TERMINATED IN FAILURE

The starting unit has reported that the execution of restart phase 1 has terminated in failure.

16702 EXECUTION OF UNIT RESTART PHASE 2 HAS TERMINATED IN FAILURE

The starting unit has reported that the execution of restart phase 2 has terminated in failure.

16703 EXECUTION OF UNIT RESTART PHASE 3 HAS TERMINATED IN FAILURE

The starting unit has reported that the execution of restart phase 3 has terminated in failure.

16704 NO RESPONSE TO EXTERNAL COMPUTER ALIVE INQUIRY

A computer unit has not responded to an external alive inquiry made by the system restart controller program block.

16705 UNIT HAS NOT RESPONSED TO START UP COMMAND

The starting unit has not responsed to the start up command given by the system restart controller program block.

16706 VP PIPE IS UNAVAILABLE

When piped leg is created, two units need to be connected. If the rivers between those two units are unreachable, this error code is returned.

16707 TIME-OUT ON SEMAPHORE

Time-out when waiting for semaphore.

16708 MGW LICENCED CAPACITY EXCEEDED

The count of the reserved call contexts in the MGW has exceeded the maximum defined by the MGW connection capacity licence. Emer-gency and priority calls will still be handled in the normal way, but all other calls will be rejected.

16709 MULTIPOINT GB IS IN USE IN PCU. (SEVERAL NSES UNDER PSE.)

Moving of Gb over IP PCU into PSE has failed because PCU has more than one NSEs -> Multipoint Gb is in use.

16710 PSE STILL HAS NS-VL(S)

PSE could not be deleted because there still are NS-VL(s) connected to it.

16711 ILLLIB NOT INITIALIZED

The ILLLIB library has not been initialized.

16712 NO CPCI BUS FOUND

Compact PCI bus was not found.

16713 CITARX FEATURE IS NOT IN USE IN BSC

Page 470: DX Error Messages

470 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The CITARX (Cell Identity, Timing Advance and RX levels) calculation method feature is not enabled in BSC (Base Station Controller).

16714 INTERFACE RATES FOR EXTERNAL INTERFACES MISSING

PHLPRB has not been able to initialize line interface rates (they are requested with service atm_configuration_parameters_as). The service has failed for some reason.

16715 INITIALIZATION OF INTERNAL LAN CONFIGURATION DATA IS NOT FINISHED YET

The initialization process of internal LAN configuration data is not finished yet and not all the data is available. The internal LAN configu-ration must not be modified during initialization. Please try again in a few minutes.

16716 ATTRIBUTE IS NOT MODIFIED ALONE

An attempt was made to modify more than one attribute simultaneously.

16717 UNIT OF DSP SERVICE IS RESTARTED (DMPG, TPG OR DSP)

leg_failure_cause: recovery_c + unit.ttype =dmpg,tpg or dsp

16718 OTHER UNIT RESTART

leg_failure_cause: recovery_c (other unit.ttype)

16719 OPERATIONAL STATE OF TRANSPORT IS DISABLED

leg_failure_cause: oam_c

16720 OPERATOR HAS LOCKED THE TRANSPORT

leg_failure_cause: adm_c

16721 SWITCH TYPE IS NOT SUPPORTED BY THIS LAN

This switch type is not supported by this LAN type.

16722 AAL2 PATH ID MISMATCH

AAL2 Path Id mismatch.

16723 UNKNOWN CONFIGURATION ID

CONFIGURATION ID in provisioning request is unknown.

16724 RNW PLAN IN WRONG STATE

The RNW Plan Database is in the wrong state.

16725 RNW PLAN DATABASE IS NOT VALIDATED

RNW Plan Database is not validated.

16726 UPLOAD OR FILE BASED PLAN PROVISIONING ONGOING

Upload or File Based Plan Provisioning ongoing.

16727 FAILURES IN PLAN ACTIVATION

Object activation has failed.

16728 DOWNLOAD HAS FAILED

Plan downloading has failed.

16729 VALIDATION HAS FAILED

Plan validation has failed.

16730 PLAN DATABASE MODIFIED

Page 471: DX Error Messages

DN987378Issue 24-0

471

General Error Messages of System DX error messages

Id:0900d8058077e097

Planned configuration is changed due to change in active configuration.

16731 RNW PLAN DATABASE STATE IS CHANGED TO CLEAR

Command caused plan database state change to CLEAR.

16732 RNW PLAN DATABASE IS ALREADY VALIDATED

An attempt has been made to validate a plan database that is already validated.

16733 PLAN DATABASE INITIALIZATION IS ONGOING

Plan database initialization is ongoing.

16734 PLAN DATABASE ACTIVATION IS ONGOING

Plan database activation is ongoing.

16735 FALLBACK NOT AVAILABLE

No fallback is available on the disk.

16736 VALIDATION ONGOING

Validation is ongoing and local changes are denied.

16737 FALLBACK ACTIVATION ONGOING

Fallback activation is ongoing and local changes are denied.

16738 WRONG TASK ID IN RNW PLAN OPERATION ABORT REQUEST

RNW Plan Management in RNC OMU has rejected the RNW plan oper-ation abort request. The task referred to is not ongoing and therefore cannot be interrupted.

16739 TOO LATE TO ABORT ONGOING RNW PLAN OPERATION

The ongoing RNW plan operation in RNC OMU has reached a point where it cannot be aborted anymore.

16740 RNW PLAN ROLLBACK OPERATION CANNOT BE ABORTED

RNW Plan Management in RNC OMU (program block RAYMAN) has rejected RNW plan operation abort request. RNW plan rollback opera-tion cannot be aborted.

16741 DUPLICATE CELL SETUP REQUEST

Cell setup request for a cell that is already set up in BTS.

16742 APCM INDEX IS TOO BIG

APCM index is too big.

16743 APCM INDEX IS TOO SMALL

The A interface PCM index is too small.

16744 APCM INDEX IS NOT FREE

A interface PCM index is not free.

16745 NO FREE APCMS

No free A interface PCMs.

16746 CIRCUIT IS IN ATER USE

The circuit has been configured for Ater use.

16747 TCPCM INDEX IS TOO BIG

Page 472: DX Error Messages

472 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

TCPCM index is too big.

16748 TCPCM INDEX IS TOO SMALL

The TCPCM index is too small.

16749 TCPCM IS NOT CONFIGURED

TCPCM is not configured.

16750 TCPCM IS RESERVED

TCPCM is reserved.

16751 CIRCUIT IS IN A CIRCUIT GROUP

The circuit is in a circuit group.

16752 CIRCUIT IS NOT CONFIGURED

The circuit is not configured.

16753 CIRCUIT POOL IS NOT SUPPORTED

Circuit pool is not supported.

16754 ET INDEX IS TOO BIG

ET index is too big.

16755 ET IS NOT CONFIGURED

ET is not configured.

16756 WORK FILE CORRUPTED

The work file has been corrupted.

16757 INCORRECT CIRCUIT POOL VALUE

Incorrect circuit pool value.

16758 INCORRECT TCPCM VALUE

Incorrect TCPCM value.

16759 NO FREE TIMESLOTS

No free timeslots.

16760 ET IS NOT IN ATER USE

ET has not been configured for Ater use.

16762 NBR OF THROUGH-CONNECTED CHANNELS IS TOO BIG

The number of through-connected channels is too big.

16763 APCM UNDEFINED

The value of the APCM parameter is undefined.

16764 NO RNW UPLOAD ONGOING

No RNW (Radio NetWork) upload is ongoing.

16765 FTP AND FTAM CONNECTIONS NOT OK

FTAM (File Transfer Access and Management) and FTP (File Transfer Protocol) connections are not working.

16766 NO ANSWER RECEIVED FROM PROCESS FH4 IN TIME

Timer for waiting an answer message from process fh4 has expired, and no answer has been received.

Page 473: DX Error Messages

DN987378Issue 24-0

473

General Error Messages of System DX error messages

Id:0900d8058077e097

16767 TRX CAPACITY LICENCE EXCEEDED

TRX capacity licence has been exceeded.

16768 TRX LICENCE NOT IN USE IN BSC

TRX licence not in use in BSC.

16769 REQUESTED SERVICE IS NOT SUPPORTED BY THE SPECIFIED DSP

An attempt was made to allocate DSP resources of a service type that is not supported in the service pool of the specified DSP.

16770 HANGING RESOURCES IN A DSP

The DSP resource manager SPRM(D) has detected hanging resources in a DSP.

16771 NEW SERVICE TYPE IS NOT SUPPORTED IN UNIT

The requested DSP service type is not configured in the unit, and another unit cannot be selected.

16772 ILLEGAL OPERATION TO LAN SWITCH THAT BELONGS TO EMB LAN

Illegal operation on the LAN switch that belongs to EMB LAN.

16773 SPRM(D) RECEIVED ERROR NOTIFICATION FROM A CHORUS ACTOR

The DSP resource manager received an error notification message from a Chorus L2 application.

16774 UNIT STATE MUST BE WO BECAUSE IT HAS A LOGICAL IP ADDRESS

The working state of the unit has to be active (WO), since it has a logical IP address.

16775 UNIT STATE MUST BE SP BECAUSE IT HAS NO LOGICAL IP ADDRESS

The working state of the unit has to be passive (SP), since it has no logical IP address.

16776 ENABLING AGPS IS NOT ALLOWED, AGPS OPTIONALITY IS NOT SUPPORTED

Enabling AGPS is not allowed because AGPS optionality is not sup-ported.

16777 ENABLING EMISHO IS NOT ALLOWED, EMISHO OPTIONALITY IS NOT SUPPORTED

Enabling EMISHO is not allowed, because EMISHO optionality is not supported.

16778 ENABLING IEMISHO IS NOT ALLOWED, IEMISHO OPTIONALITY IS NOT SUPPORTED

Enabling IEMISHO is not allowed because IEMISHO optionality is not supported.

16779 ENABLING LCS IS NOT ALLOWED, LCS OPTIONALITY IS NOT SUP-PORTED

Page 474: DX Error Messages

474 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Enabling LCS is not allowed because LCS optionality is not supported.

16780 STIRC FEATURE IS NOT IN USE IN THE BSC

The STIRC feature is not enabled in the BSC. Either the license of the feature is not valid, or the state of the feature is OFF or CONFIG.

16781 BTS SW DOES NOT SUPPORT STIRC FEATURE

The BTS software does not support the STIRC feature.

16782 STIRC TRX COUNT CAPACITY LICENCE EXCEEDED

The STIRC TRX count capacity license has been exceeded. There are too many TRXs under STIRC-enabled (STIRC=Y) BTSs.

16783 NOT ALL UNLOCKED TRXS UNDER STIRC-ENABLED BTS ARE STIRC CAPABLE

All TRXs under a STIRC-enabled BTS object must be STIRC capable. A TRX is STIRC capable if the TRX is EDGE TRX; with UltraSite, also non-EDGE TRX with BB2E/BB2F baseband boards and non-EDGE RFU (TSxA) are STIRC capable.

16784 E-TRX NOT ALLOWED IN STIRC-ENABLED BTS

Extended cell does not work in the same BTS with the STIRC feature. E-TRX cannot be used in a STIRC-enabled BTS (STIRC=Y).

16785 NO SPACE FOR TCPCM

There is no space for TCPCM.

16786 ATTEMPTED TO ENABLE OPTIONS IEMISHO AND EMISHO SIMUL-TANEOUSLY

An attempt has been made to enable options IEMISHO and EMISHO simultaneously. This is not allowed.

16787 CONFLICTING TCPCM

The operation is not allowed because of conflicting TCPCM.

16788 BACKGROUND ACTIVATION ONGOING

Background activation is ongoing and file-based plan download is denied.

16789 PLAN PROVISIONING DATABASE COPY ONGOING

Plan provisioning related database copy is ongoing.

16790 ROUTING AREA NSEI LIST COULD NOT BE UPDATED

The NSEI list in the Routing Area(s) could not be updated during NS-VL/NSE creation or deletion due to the state of the Plan database. NSEI has to be added to or removed from the routing area manually.

16791 BCSU RESET IS ONGOING

Continuing RNW plan data activation is not possible because of an ongoing BCSU reset.

16792 MORE THAN 2 SAME SECTOR IDS PER BTS EXIST IN THE CELLS WHERE DIRECTEDRRCENABLED IS HSDPA

There must not be more than two layers. This is checked from SectorID: No more than 2 same SectorIDs per BTS exist in the cells where Direct-edRRCEnabled is HSDPA layer.

Page 475: DX Error Messages

DN987378Issue 24-0

475

General Error Messages of System DX error messages

Id:0900d8058077e097

16793 FTAM CONNECTION SETUP FAILED

Error occured when establishing FTAM connection.

16794 NO ANSWER RECEIVED IN TIME FROM PROCESS LBC

The timer for waiting for an answer message from process LBC has expired, and no answer has been received.

16795 PRIORITY OF SIB18 MUST NOT BE HIGHER THAN PRIORITY OF SIB11 OR SIB12

The priority of SIB18 must not be higher than that of SIB11 or SIB12.

16796 SIMULTANEOUS ENABLING OF HSDPARRCDIVERSITY AND HSD-PAMOBILITY PARAMETERS IS NOT ALLOWED

It is not allowed to enable the parameters HSDPADiversity and HSDPA-Mobility simultaneously.

16797 ATER SERVICES NOT AVAILABLE

The ZATERI library returns this error code when Ater services are not available.

16798 WLCSE TO SAME UC ID ALREADY EXISTS

A WLCSE to the same UC ID exists already.

16799 RT HSDPA FMCS IDENTIFIER MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

HSDPA FMCS identifier for AMR multi-service must be defined if HSDPA is enabled for the WCEL.

16800 RT HSDPA FMCI MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

HSDPA FMCI for AMR multi-service must be defined if HSDPA is enabled for the WCEL.

16801 RT HSDPA FMCG MUST BE DEFINED IF HSDPA ENABLED FOR THE WCEL

HSDPA FMCG for AMR multi-service must be defined if HSDPA is enabled for the WCEL.

16802 HSDPA HOPS FOR AMR MULTI-SERVICE MUST BE DEFINED FOR THE OUTGOING ADJS OF THE WCEL

HSDPA HOPS for AMR multi-service must be defined for the outgoing ADJS of the WCEL.

16803 HSDPA HOPS FOR AMR MULTI-SERVICE MUST BE DEFINED FOR THE SOURCE WCEL

HSDPA HOPS for AMR multi-service must be defined for the source WCEL.

16804 LOGICAL ADDRESS IS NOT VALID.

The logical address is not valid.

16805 PARAMETER OF MESSAGE IS WRONG

CAC has received a message with a wrong parameter.

16806 THERE IS NO FREE MXU EGRESS BANDWIDTH

Page 476: DX Error Messages

476 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

CAC refuses the connection request because there is no free MXU egress bandwidth.

16807 THE PARAMETER IS NOT SAVED BY DIUSON

DIUSON cannot find the parameter because it has not been saved by DIUSON.

16808 THERE IS NO FREE BUFFER TO SAVE DIUSON PARAMETER

The DIUSON parameter cannot be saved because there is no free buffer.

16809 PORT TYPES DO NOT MATCH

It is not allowed to connect different types of ports to each other. Check that you gave the correct port locations in the command.

16810 ILLEGAL PLKLIB LIBRARY FUNCTION CALL IN THIS COMPUTER UNIT

There are different PLKLIB libraries for different processor units. Not all PLKLIB services are implemented in every PLKLIB library. This error code is returned when the program calls a PLKLIB library function that is illegal in the unit in question.

16811 INCORRECT PORT DIRECTION

Ports with the same direction may not be connected to each other. The direction of port type SFPIF in the switching fabric plug-in unit must be from the switching fabric, and in other plug-in units it must be to the switching fabric. Possible direction rules with port types other than SFPIF must be followed as well.

16812 VLAN IP CONFIGURATION EXISTS

Remove the IP configuration from the VLAN interface before deleting it.

16813 VLAN INTERFACE EXISTS ALREADY

The VLAN interface exists already.

16814 VLAN CONFIGURATION FAILED

VLAN configuration has failed.

16815 LOCAL CELL DELETED FROM THE BTS

The local cell of the BTS has been deleted.

16816 UNSURE TO KNOW UNIT EXISTENCE

Unsure to know unit existence

16817 CMP ENROLL OPERATION BUSY

CMP enroll operation busy. Try again soon.

16818 PSEI AND PCU IDENTIFIER PARAMETERS CANNOT BE IN SAME REQUEST.

The PSEI parameter and the PCU identification parameters cannot be included in the request simultaneously. Used by OCHs in responses to the NetAct.

16820 INVALID SSH KEY TYPE

An undefined SSH key type has been given.

Page 477: DX Error Messages

DN987378Issue 24-0

477

General Error Messages of System DX error messages

Id:0900d8058077e097

16821 ENABLING THE HSDPA SERV CELL CHANGE AND SHO NOT ALLOWED BECAUSE OPTIONALITY NOT SUPPORTED

Enabling HSDPA serving cell change and SHO is not allowed because the optionality is not supported.

16822 FCPKEY FAILED TO GET AN XML PARSER

FCPKEY failed to create an XML parser.

16823 SSH REMOTE PUBLIC KEY IS INVALID

The defined remote public key is not valid.

16824 XML UPDATE FAILED

Updating an XML element has failed.

16825 SSH CONFIGURATION ALREADY EXISTS

The requested SSH configuration already exists in the defintions file.

16826 UNIT CONFIGURATION NOT FOUND

The configuration information of the unit was not found.

16827 FAN TRAY UNIT MISSING

The fan tray unit is not connected to the HMSS node that tries to control it.

16828 HMS NODE FAILED IN REQUESTED OPERATION

The HMS node has failed in the requested operation.

16829 FAN TRAY POWER ALREADY OFF

The power has already been shut down in the fan tray unit.

16830 OPERATION TARGET IS NOT POWER PLUG-IN UNIT

The target of the requested operation is not a power plug-in unit capable of controlling a fan tray.

16831 UNDEFINED ERROR CODE RECEIVED FROM HMS CORE

The HMS interface software has received an undefined error code from the HMS core.

16832 MISMATCH BETWEEN REQUESTED AND RECEIVED SENSOR ID

The HMS node answered with a different sensor ID than requested.

16833 NO REQUESTED SENSOR ON TARGET

The sensor requested in the operation does not exist on the target.

16834 I2C MALFUNCTION IN HMS

A malfunction has occurred in the I2C bus connected to the HMS node.

16835 MISMATCH BETWEEN SET ROTATION SPEED AND ACKNOWL-EDGED ROTATION SPEED

The HMSS node controlling the fan tray unit has returned a different rotation speed value than the one requested in the operation.

16836 HMSS COULD NOT SET REQUESTED ROTATION SPEED

The HMSS node could not set the requested rotation speed for the fan tray unit.

16837 UNKNOWN FAN GROUP INFORMATION RECEIVED

Page 478: DX Error Messages

478 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The HMSS node controlling the fan tray unit has returned an illegal fan group.

16838 NO ACKNOWLEDGEMENT RECEIVED FROM HMS CORE

No response message to the operation has been received from the HMS core.

16839 MISMATCH BETWEEN REQUESTED AND ACKNOWLEDGED LED STATUS IN FAN TRAY

The HMSS node returned an LED status different from the one requested in the operation.

16840 ALL AAL2 UP LINKS IN SAME VCC MUST HAVE SAME AAL2UPUSAGE VALUE

Only one AAL2UPUsage (for example "shared") is allowed for one VCC.

16841 SHARED OR DEDICATED TRANSPORT SOLUTION SHOULD BE SELECTED FOR ALL AAL2 UP LINKS

All aal2 userplane links in one COCO must be either shared or dedicat-edones. It is not allowed to have both shared and dedicated AALUPUs-age values in the same COCO.

16842 DCH DEDICATED VCC IS MISSING FROM ROUTE

At least one DCH dedicated VCC is needed per route if dedicated trans-port solution is used.

16843 HSDPA DEDICATED VCC IS MISSING FROM CONNECTION CON-FIGURATION OBJECT

One HSDPA dedicated VCC is required per COCO/WBTS if dedicated transport solution is used.

16844 ONLY ONE HSDPA VCC IS ALLOWED PER ROUTE

There can be only one HSDPA dedicated VCC per route.

16845 ENDPOINT USAGE MISMATCH IN ENDPOINT SELECTION

The requested endpoint type does not match the usage of endpoints configured.

16846 SHARED AND DEDICATED ENDPOINT CANNOT BE LOCATED IN THE SAME ROUTE

Shared and dedicated ENDPOINT cannot be located in the same route.

16847 ERROR IN KAKOLA FILE UPDATING

An error has occurred while updating the KAKOLA file.

16848 HMS REQUESTED TO CONTROL NONEXISTING EXTERNAL DEVICE

A request has been made to the HMS to control an external device with an incorrect device ID. No such device ID is controlled by this HMS node.

16849 HMS NODE DOES NOT SUPPORT REQUESTED OPERATION

The feature that was supposed to be used in the requested operation is not supported by the HMS node involved in the operation.

Page 479: DX Error Messages

DN987378Issue 24-0

479

General Error Messages of System DX error messages

Id:0900d8058077e097

16850 KAKOLA FILE OPERATION ERROR

Error in KAKOLA file handling. Possible causes are, for example, that the file is missing, that it cannot be opened, or that data is corrupted.

16851 ROUTE SELECTION IS NOT ENABLED TO SO MANY BTS

Route selection is not enabled to so many BTS.

16852 PLAN PROVISIONING DATABASE COPY IS ONGOING

Plan provisioning-related database copy is ongoing.

16853 SUBSCRIBER DOES NOT EXIST. N+X QUERY IS REQUIRED

The subscriber does not exist in the distributor files. Due to RHLR, a new query to N+X is required.

16854 LDAP CONFIGURATION DATA NOT FOUND

Some critical LDAP configuration data cannot be found on the LDAP configuration server.

16855 LICENCE TASK INTERRUPTED BY SWITCHOVER

The licence handling task was interrupted because of a unit switchover.

16856 THE PAIR OF THE BRANCH IS NOT FOUND

The pair of the leg branch cannot be found in the call. The application should reserve a pair for the leg first.

16857 CMOB ALREADY CREATED

The Configuration Management Object (CMOB) has already been created in the Radio Network Database.

16858 CMOB NOT FOUND

The Configuration Management Object (CMOB) cannot be found in the Radio Network Database.

16859 FAKE FLASH CBOOTA NOT FOUND

FAKE FLASH CBOOTA NOT FOUND

16860 THE OPTICAL MODULE IS BROKEN OR MISSING

The given optical module is not properly installed in its place or it is broken.

16861 PCU IS ALREADY USING FR IN GB INTERFACE

An attempt is being made to configure the Gb interface in the PCU using an IP configuration, but a Frame Relay configuration is already in use.

16862 PCU IS ALREADY USING IP IN GB INTERFACE

An attempt is being made to configure the Gb-interface in the PCU using an FR configuration, but an IP configuration is already in use.

16863 BUNDLE EXISTS IN THE TABLE

BUNDLE exists in the table.

16864 BUNDLE TABLE IS FULL

The BUNDLE table is full.

16865 BUNDLE DOES NOT EXIST IN THE TABLE

BUNDLE does not exist in the table.

Page 480: DX Error Messages

480 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

16866 UNIT OPERATES AS CODE LOADING SOURCE

The unit works as the loading source for the code, and thus the unit cannot be restarted or its state cannot be successfully changed.

16867 IP PROTOCOL VERSION IS NOT SUPPORTED

The required IP protocol version is not supported in the current computer unit or by a specific software process.

16868 INQUIRY OF DATA FROM EQUIPMENT DATABASE FAILED

Data stored in the equipment database could not be retrieved.

16869 ACTION NOT ALLOWED DURING HMS SEPARATION

The attempted action is not allowed during HMS separation.

16870 PRFILE PARAMETER AUTOMAT_HW_CONFIGURAT IS OFF

The attempted action cannot be performed because the PRFILE parameter automat_hw_configurat is off.

16871 EQSELF IS NOT READY FOR THE OPERATION

The attempted action cannot be performed because EQSELF is still in the start-up phase.

16872 UPDATE OF DATA TO EQUIPMENT DATABASE FAILED

Equipment database update failed.

16873 COMPARISION OF HW AND EQUIPMENT DATABASE FAILED

The comparison of the actual HW (EEPROMs) to its description (equip-ment database) has failed.

16874 FILE LOADING SOURCE CONFLICT

The proposed file loading source is own unit. File loading from own unit is not allowed.

16875 ALL NBAP-D LINKS ARE DOWN

All NBAP-D links are down.

16876 RECEIVED KEYS DO NOT EXIST

The received keys do not exist in the system.

16877 TERMINAL TYPE IS NOT SUPPORTED

The received terminal type is not supported by the system.

16878 PHYTTP LIMIT FOR NETWORK INTERFACE UNIT EXCEEDED

The physical layer trail termination point (phyTTP) cannot be created because the maximum amount of phyTTPs in the network interface unit has been exceeded.

16879 DATA MISMATCH BETWEEN THE IULMAN WORK FILE AND ANOTHER D-CHANNEL FILE

Data mismatch between the IULMAN work file and another D-channel file.

16880 IUBADM BUSY

The program block IUBADM is not capable of receiving new tasks. Try again later.

16881 ASSOCIATION ALREADY EXISTS

Page 481: DX Error Messages

DN987378Issue 24-0

481

General Error Messages of System DX error messages

Id:0900d8058077e097

The given association already exists.

16882 ASSOCIATION IS IN USE

The given association is in use.

16883 ADJUSTABLE INTELLIGENT SHUTDOWN FOR SITE TYPE NOT IN USE IN BSC

The adjustable intelligent shutdown for the site type is not in use in the BSC. The feature requires a licence.

16884 ADJUSTABLE INTELLIGENT SHUTDOWN FOR TALK-FAM-ILY/METRO/ULTRA BTS NOT IN USE IN BSC

Talk-family/Metro Site/Ultra Site adjustable intelligent shutdown is not in use in the BSC. The feature requires a licence.

16885 INVALID SHUTDOWN GROUP FOR BCCH TRX

Invalid TRX shutdown group for BCCH TRX. A BCCH TRX shutdown group cannot be another group than group 0.

16886 FLOATING POINT CALCULATION DISABLED

Floating point calculation was requested, but it is not allowed.

16887 SSH INITIALIZATION FAILED

SSH Initialization failed.

16888 DATA RECEIVE OVER SSH FAILED

Data receive over SSH failed.

16889 UNABLE TO CREATE FILE

Unable to create file.

16890 WRITING TO TEMPORARY FILE FAILED

Writing to temporary output file failed.

16891 UNABLE TO CREATE LOGICAL FILE

Logical file creation failed.

16892 LINKING LOGICAL FILE TO PHYSICAL FAILED

Linking of logical file to physical file failed.

16893 SSH INTERFACE ERROR

An unexpected error has occurred in the SSH interface.

16894 SFTP SERVICE STARTUP FAILED

Unable to start SFTP services.

16895 STREAM IS IN USE

The given stream is in use.

16896 NO FREE STREAM

There is no free stream.

16897 INTERFACE IDENTIFIER IS IN USE

The given interface identifier is in use.

16898 PHMSEB MODIFICATION IS NOT ALLOWED.

Page 482: DX Error Messages

482 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

PHMSEB modifications have been denied by the Distributed part of the PHMSEB. Try again later.

16899 NO ATTEMPT TO RESERVE RESOURCE

No attempt to reserve resource.

16900 PROTECTION GROUP DOES NOT EXIST

The protection group is not created.

16901 PREVIOUS CONFIGURATION IS STILL IN PROGRESS

The previous configuration operation is still in progress. There cannot be two simultaneous configuration operations in execution.

16902 CONFIGURATION FAILED

The executed configuration operation has failed. Check possible error logs for more information.

16903 PCU CANNOT CONNECT TO DNS SERVER

PCU attempts to resolve the IP address by Remote Host Name during NS-VL creation. The DNS server does not respond to the request.

16904 KAKOLA DISK UPDATING FAILED

KAKOLA file could not be updated to the disk.

16905 PACKET DATA OPTIMISATION PACKAGE FEATURE IS NOT IN USE IN BSC

Packet Data Optimisation package feature is not in use in BSC.

16906 INVALID EDAP LOAD THRESHOLD PARAMETER

Invalid EDAP Load threshold parameter.

16907 INVALID SESSION TYPE

The used session type value is not valid.

16908 SP OMU STATE INCORRECT

The operation is not allowed because the state of SP OMU is incorrect.

16909 WO OMU STATE INCORRECT

The operation is not allowed because the state of WO OMU is incorrect.

16910 SP CACU STATE INCORRECT

The operation is not allowed because the state of SP CACU is incorrect.

16911 WO CACU STATE INCORRECT

The operation is not allowed because the state of WO CACU is incor-rect.

16912 SP CM STATE INCORRECT

The operation is not allowed because the state of SP CM is incorrect.

16913 WO CM STATE INCORRECT

The operation is not allowed because the state of WO CM is incorrect.

16914 SP ISU STATE INCORRECT

The operation is not allowed because the state of SP ISU is incorrect.

16915 WO ISU STATE INCORRECT

Page 483: DX Error Messages

DN987378Issue 24-0

483

General Error Messages of System DX error messages

Id:0900d8058077e097

The operation is not allowed because the state of WO ISU is incorrect.

16916 VIRTUAL BUNDLE IDENTIFIER IS OUT OF ITS RANGE

The virtual bundle identifier is out of its range.

16917 VIRTUAL BUNDLE IDENTIFIER EXISTS ALREADY

The virtual bundle identifier is out of its range.

16918 VIRTUAL BUNDLE IDENTIFIER DOES NOT EXIST

The virtual bundle identifier does not exist.

16919 NO FREE VIRTUAL BUNDLE IDENTIFIER FOUND

No free virtual bundle identifier could be found.

16920 VCCEP SC OPT MISMATCH

The service categories of vcltp and optimization do not match.

16921 VCCEP IN BUNDLE UNDER DIFFERENT INTERFACE

Vcceps in a bundle are not in the same interface.

16922 SL TPI IS NOT BLANK WHEN PROTOCOL IS MTP3

MTP3 is used as signalling protocol. sl_tpi should not be included in the request.

16923 SL TPI SHOULD BE FILLED FOR SAAL

SAAL UNI is used as signalling protocol. sl_tpi should be included in the request.

16924 DOMAIN NAME HAS MAX NUMBER OF CNAMES

Error for etc/hosts file managing. This error occurs when one domain name has the maximum number of canonical names.

16925 DOMAIN HAS MAX NUMBER OF ALIAS IP ADDRESSES

This error is for managing etc/hosts file. This error occurs when the domain name has the maximum number of alias IP addresses.

16926 END OF AVP REACHED

End of AVP reached.

16927 DIAMETER GENERAL ERROR

Diameter general error.

16928 NO MEMORY ERROR

No memory error.

16929 ASSERTION ERROR

An assertion error has occurred.

16930 DISCONNECT ERROR

Disconnect error.

16931 SPECIFIED TIMELIMIT REACHED

The specified time limit has been reached.

16932 INVALID LENGTH

Invalid length.

16933 UNKNOWN PEER

Page 484: DX Error Messages

484 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Unknown peer.

16934 PEER IS DOWN

Peer is down.

16935 INVALID DIAMETER VERSION

Invalid Diameter version.

16936 NO OPEN CONNECTION AVAILABLE

No open connection available.

16937 MEMORY ALLOCATION FAILED

Memory allocation failed.

16938 NO DATA COMING FROM SOCKET

No data coming from socket.

16939 SOCKET CREATION ERROR

Socket creation error.

16940 UNSUCCESSFUL CER CEA HANDSHAKE

Unsuccessful CER CEA handshake.

16941 LOCAL IP BIND FAILED

Local IP bind failed.

16942 REMOTE IP BIND FAILED

Remote IP bind failed.

16943 CANNOT CONNECT SOCKET.

Cannot connect socket.

16944 ERROR IN MAKING SETSOCKOPT()

Error in making setsockopt().

16945 ERROR IN MAKING GETSOCKOPT()

Error in making getsockopt().

16946 ILLEGAL PTR

Illegal pointer.

16947 ILLEGALLY FORMED DIAMETER HEADER

The Diameter header is illegally formed.

16948 ERROR IN PUTTING AVP TO DIAMETER MESSAGE

Error in putting AVP to Diameter message.

16949 UNKNOWN AVP CODE

Unknown AVP code.

16950 ILLEGALLY FORMED AVP-GROUPED

Illegally formed AVP-Grouped.

16951 AAL2 CROSS-CONNECTION IS REJECTED BECAUSE OF THE PCR TUNING FAILURE

AAL2 cross-connection has been rejected because the PCR tuning cal-culation inside the VCC bundle has failed.

Page 485: DX Error Messages

DN987378Issue 24-0

485

General Error Messages of System DX error messages

Id:0900d8058077e097

16952 WSMLC IU-PC INTERFACE NOT SUPPORTED

To set the Stand-Alone SMLC (SAS) interface to IU-PC, one of the fol-lowing optionality combinations is required: 1. NETWORK ASSISTED GPS and IU PC INTERFACE FOR NETWORK ASSISTED GPS 2. ASSISTED GPS and IU PC INTERFACE FOR NETWORK ASSISTED GPS

16953 NCID BUNDLE ALREADY EXISTS IN CAC LEVEL

NCID bundle already exists in CAC level.

16954 NCID BUNDLE TABLE IS FULL IN CAC LEVEL

NCID bundle table is full in CAC level.

16955 NCID BUNDLE DOES NOT EXIST IN CAC LEVEL

NCID bundle does not exist in CAC level.

16956 NCID OPTIMIZATION FLAG ILLEGAL

NCID optimization flag illegal.

16957 ATM PRIORITY ILLEGAL

ATM priority illegal.

16958 DUMMY HSDPA RESERVATION IS NOT ALLOWED FOR DEDI-CATED NCID

Dummy HSDPA reservation is not allowed for dedicated NCID.

16959 IU PC INTERFACE FOR NETWORK ASSISTED GPS NOT CONFIG-URED

To configure the IU PC parameters, IU PC INTERFACE must be sup-ported. UE Based A-GPS using external reference network and/or NW Based A-GPS using external reference network features must be sup-ported as well.

16960 WSMLC A-GPS DATA INTERFACE NOT SUPPORTED

To set the Stand-Alone SMLC (SAS) interface to WSMLC A-GPS Data Interface, one of the following optionality combinations is required: 1. NETWORK ASSISTED GPS and ADIF INTERFACE FOR NETWORK ASSISTED GPS 2. ASSISTED GPS and ADIF INTER-FACE FOR NETWORK ASSISTED GPS

16961 SSH SERVER IS NOT ACTIVATED

SSH Server must be activated before SFTP Server can be activated.

16962 FEATURE ACTIVATION STATUS CHECK FAILED

Activation status of optional feature has failed.

16964 INVALID PCM RATE

The data rate for a PCM is invalid.

16965 INVALID TDM8M HIGHWAY

TDM8M highway is invalid.

16966 INVALID DIRECTION OF TDM8M HIGHWAY

The direction of TDM8M highway is invalid.

16967 INVALID TDM SNOOPING WINDOW SIZE

Page 486: DX Error Messages

486 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

TDM snooping window size is invalid.

16968 INVALID TEST MODE OF TTMC2

Test mode of TTMC2 is invalid.

16969 PZWLIB INITIALIZATION FAILED

Initialization of PZWLIB has failed.

16970 ILLEGAL AAL2 SIGNALING LINK RELATED TO COCO USER PLANE LINK.

The AAL2 Signaling link associated to the COCO user plane link is illegal.

16971 AAL2 SIGNALING LINK MISMATCH FOR COCO USER PLANE LINK.

AAL2 Signaling link associated to COCO user plane link mismatch for same VCC.

16972 A2EA ADDRESS MISMATCH FOR COCO USER PLANE IN THE SAME WAM.

Different A2EA addresses are found for the same WMA when the AAL2 generation rule is none_c.

16973 AAL2 SIGNALING LINK MISMATCH FOR COCO USER PLANE IN THE SAME WAM.

Different AAL2 signaling links are found for the same WAM when AAL2 multiplexing is not used.

16974 LOCAL IP FAILURE

Local IP failure.

16975 TOO MANY FLEXIBLE VPC ENABLED COCO OBJECTS CONFIG-URED

The total number of Flexible VPC enabled COCO objects exceeds the maximum optional value.

16976 VP ID OF COCO C-NBAP, D-NBAP, AAL2SIG, AAL2TP LINK SHOULD BE FOUND IN COCO VPI LIST.

VP ID of COCO C-NBAP, D-NBAP, AAL2SIG, AAL2TP link should be found in the COCO VPI list.

16977 REMOVE BUNDLE WITH VCCS

Some VCCs exist in the bundle. Therefore the bundle cannot be removed.

16978 SAME VCI ALREADY EXISTS IN THE BUNDLE

The VCI already existed at the time of creating the same VCI in the bundle.

16979 NO FREE BUNDLE BANDWIDTH

The bandwidth of the VCCs in the bundle exceeds the limit.

16980 NUMBER OF VCCS WITHIN BUNDLE EXCEEDS THE MAX LIMIT

The number of VCCs in the bundle exceeds the max limit.

16981 GIVEN AAL2 SERVICE CATEGORY DOES NOT MATCH VCCEP USAGE

Page 487: DX Error Messages

DN987378Issue 24-0

487

General Error Messages of System DX error messages

Id:0900d8058077e097

The AAL2 service category given for 1CID does not match the VCCEP usage of NCID.

16982 ILLEGAL ATM PRIORITY FOR SPECIFIC SERVICE CATEGORY

Illegal ATM priority for specific service category.

16983 ILLEGAL NCID OPTIMIZATION FOR SPECIFIC SERVICE CATEGORY

Illegal NCID optimization for specific service category.

16984 DUMMY HSDPA RESERVATION IS NOT ALLOWED FOR NON-SHARED VCC

Dummy HSDPA reservations are not allowed for non-shared VCCs.

16985 CELL RANGE OF WCEL IS INCORRECT

The maximum cell range can be larger than 10 km only when two antennas are used and AICH Transmission Timing has the value 1.

16986 SSH SERVER USES KEY AND IT CANNOT BE DELETED

When deleting keys from the key database, SSH handling is asked if it uses these keys. If a key is in use, it cannot be deleted.

16987 VETGR UPDATE FAILURE

The update of a configuration change to the VETGR unit has failed. Files in the other units have been updated.

16988 BRTSEB IS IN WARMING

BRTSEB is in warming.

16989 CHANNEL NUMBER OUT OF RANGE

The channel number is out of range.

16990 LEVEL 2 NOT SYNCHRONIZED

Level 2 is not synchronized.

16991 LEVEL 3 HALTED

Level 3 halted.

16992 LEVEL 3 RESET

Level 3 reset.

16993 LINK NUMBER OUT OF RANGE

The link number is out of range.

16994 PROTOCOL DRIVER NOT ATTACHED

Protocol driver not attached.

16995 NO CSI STRUCTURE AVAILABLE

No CSI structure is available.

16996 LEVEL 2 HALTED

Level 2 halted.

16997 INVALID EXCHANGE

Invalid exchange.

16998 INVALID REQUEST DESCRIPTOR

Page 488: DX Error Messages

488 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Invalid request descriptor.

16999 EXCHANGE FULL

The exchange is full.

17000 NO ANODE

No anode.

17001 INVALID REQUEST CODE

Invalid request code.

17002 INVALID SLOT

Invalid slot.

17003 BAD FONT FILE FORMAT

Bad font file format.

17004 MACHINE IS NOT ON THE NETWORK

The machine is not on the network.

17005 PACKAGE NOT INSTALLED

The package is not installed.

17006 ADVERTISE ERROR

Advertise error.

17007 SRMOUNT ERROR

Srmount error.

17008 COMMUNICATION ERROR ON SEND

Communication error on send

17009 RFS SPECIFIC ERROR

RFS specific error

17010 NAME NOT UNIQUE ON NETWORK

The name is not unique on the network.

17011 FILE DESCRIPTOR IN BAD STATE

File descriptor in bad state.

17012 REMOTE ADDRESS CHANGED

The remote address has changed.

17013 CANNOT ACCESS NEEDED SHARED LIBRARY

Cannot access a needed shared library.

17014 ACCESSING A CORRUPTED SHARED LIBRARY

Accessing a corrupted shared library.

17015 .LIB SECTION IN A.OUT CORRUPTED

.lib section in a.out corrupted.

17016 ATTEMPTING TO LINK IN TOO MANY SHARED LIBRARIES

Attempting to link in too many shared libraries.

17017 CANNOT EXEC A SHARED LIBRARY DIRECTLY

Cannot execute a shared library directly.

Page 489: DX Error Messages

DN987378Issue 24-0

489

General Error Messages of System DX error messages

Id:0900d8058077e097

17018 INTERRUPTED SYSTEM CALL SHOULD BE RESTARTED

Interrupted system call should be restarted.

17019 STREAMS PIPE ERROR

Streams pipe error

17020 STRUCTURE NEEDS CLEANING

The structure needs cleaning.

17021 NOT A XENIX NAMED TYPE FILE

Not a XENIX named type file

17022 NO XENIX SEMAPHORES AVAILABLE

No XENIX semaphores are available.

17023 IS A NAMED TYPE FILE

Is a named type file

17024 REMOTE I/O ERROR

Remote I/O error.

17025 NO MEDIUM FOUND

No medium found.

17026 WRONG MEDIUM TYPE

Wrong medium type.

17027 NO MESSAGE OF DESIRED TYPE

No message of desired type.

17028 IDENTIFIER REMOVED

Identifier removed.

17029 DEVICE NOT A STREAM

Device not a stream.

17030 NO DATA AVAILABLE

No data available.

17031 TIMER EXPIRED

Timer expired.

17032 OUT OF STREAMS RESOURCES

Out of streams resources.

17033 LINK HAS BEEN SEVERED

The link has been severed.

17034 PROTOCOL ERROR

Protocol error

17035 MULTIHOP ATTEMPTED

Multihop attempted.

17036 NOT A DATA MESSAGE

Not a data message

17037 VALUE TOO LARGE FOR DEFINED DATA TYPE

Page 490: DX Error Messages

490 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The value is too large for the defined data type.

17038 ILLEGAL BYTE SEQUENCE

Illegal byte sequence.

17039 TOO SMALL NCID PCR VALUE

The PCR of the VC link termination point is too small for an AAL2 endpoint with the given ATM priority.

17040 TOO SMALL NCID MCR VALUE

The MCR of the VC link termination point is too small for an AAL2 endpoint with the given ATM priority.

17041 LAN ELEMENT AND LAN ARE ALREADY CONNECTED IN ILDATA DATABASE

The connection between the LAN element and LAN already exists in the ILDATA database. Therefore the connection cannot be created again in the ILDATA database.

17042 LAN ELEMENT AND LAN ARE NOT CONNECTED IN ILDATA DATABASE

The connection between the LAN element and LAN does not exist in the ILDATA database and therefore it cannot be removed from the data-basa, or the query of the data has failed because the connection between the LAN element and LAN was not found in the ILDATA data-base.

17043 WLCSE COLLECTION FULL

There is no room for a new WCDMA Location Services Element (WLCSE) object in the radio network database.

17044 MAXIMUM NUMBER OF WLCSES EXCEEDED

Wlcse creation failed because the maximum number of wlcses in the RNW database has already been reached.

17045 AAL2 UP LINKS IN SAME VCC CANNOT HAVE DIFFERENT PATHTYPE VALUES

AAL2 UP links in the same VCC should have the same AAL2PathType value.

17046 PATH SELECTION IS NOT ENABLED TO SO MANY BTS

The total number of Path Selection enabled COCO objects exceeds the maximum optional value.

17047 SUM OF PTXMAXHSDPA AND PTXTARGETHSDPA IS GREATER THAN PTXCELLMAX

For each WCEL the sum of PtxMaxHSDPA and PtxTargetHSDPA must be less than or equal to PtxCellMax.

17048 HSDPA16KRETURNCHANNEL NOT ON

If the RNC parameter HSDPA16KBPSReturnChannel is off, a 16kbps value is not allowed for the following parameters: HSDPAminAllowed-BitrateUL, HSDPAinitialBitrateUL.

17049 HSDPACHATYPESWITCHWINDOW NOT LESS THAN HSDPASER-VCELLWINDOW

Page 491: DX Error Messages

DN987378Issue 24-0

491

General Error Messages of System DX error messages

Id:0900d8058077e097

HSDPAChaTypeSwitchWindow should have a smaller value than value than HSDPAServCellWindow.

17050 LBTS NOT FOUND

LBTS not found in RNW database.

17051 LBTS ALREADY CREATED

The LBTS object has already been created in the RNW database.

17052 LBTS COLLECTION FULL

There is no room for a new Local Base Transceiver Station (LBTS) object in the radio network database.

17053 CMOB COLLECTION FULL

There is no room for a new Configuration Management Object (CMOB) in the radio network database.

17054 SAME COCO OBJECT UNDER OPERATION SIMULTANEOUSLY.

Same COCO Object under operation simultaneously in VEXELI.

17055 ATM TRAFFIC PROFILE ID IS MISSING FOR COCO LINK.

The ATM traffic profile ID for the COCO link cannot be found in the traffic profile list.

17056 HSDPA FEATURE IS NOT SUPPORTED

The HSDPA feature is not supported in RNC.

17057 ILLEGAL TRAFFIC PARAMETER DEFINED IN COCO OBJECT.

The traffic parameter defined in the COCO object is invalid.

17058 UNUSED ATM IF OR VP IN COCO OBJECT.

Every ATM IF or VP in COCO object should be used by any COCO link.

17059 UNUSED AAL2 SIGNALING LINK IN COCO OBJECT.

Every AAL2 Signaling link defined in the COCO object should be used by some AAL2 user plane link.

17060 COCO AAL2 PATH UNBLOCKING IS ABORTED.

COCO AAL2 path unblocking is aborted. The reason for this may be, for example, that plan or GUI has requested a COCO operation (modifica-tion, deletion, or COCO-BTS disconnection) for the same object.

17061 USE OF BB HOP OR UNDERLAY RF HOP DENIED IN THE BTS WITH EGSM FREQ AND PGSM BCCH TRX

Using of BB or RF hopping is not allowed in BCCH BTS, if the BCCH frequency is PGSM900 type and EGSM frequency is used in the BCCH BTS.

17062 USING OF DFCA NOT ALLOWED IN THE BTS WITH PGSM BCCH TRX AND EGSM FREQUENCY

DFCA must not be used in the BCCH BTS if the BCCH frequency is of PGSM900 type and EGSM900 frequencies are also used in the BCCH BTS.

17063 SUPER-REUSED TRX (FRT=/0) AND EGSM FREQUENCY NOT ALLOWED IN BTS WITH PGSM BCCH TRX

Page 492: DX Error Messages

492 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Super-reused TRX (FRT =/0) must not be used in BCCH BTS if the BCCH frequency is of PGSM900 type and if an EGSM900 frequency is used in the BCCH BTS.

17064 GSM900 FREQ BAND IS NOT ALLOWED IN NON-BCCH BTS OF SEG IF PGSM BCCH BTS USES EGSM FREQ

The GSM900 frequency band must not be used in a non-BCCH BTS if the BCCH frequency is of PGSM900 type and an EGSM900 frequency is also used in the BCCH BTS.

17065 RT_DCH OR NRT_DCH DEDICATED VCC IS MISSING FROM ROUTE

At least one VCC for RT and one VCC for NRT DCH traffic typyes must be configurated on one route.

17066 FTP CONNECTION COULD NOT BE ESTABLISHED

FCPROG was unable to establish an FTP connection.

17067 FTP LOGIN FAILED

FTP SERVER did not accept the provided user credentials, login failed.

17068 NO ROUTE TO FTP HOST

No route to FTP host.

17069 FTP OPERATION NOT SUCCESSFUL

The FTP operation has failed. The server replied with an error.

17070 ATM PARAMETERS ARE NOT MODIFIED

ATM parameters are not modified.

17071 SUBNET CONNECTION IS NOT FOUND FOR THE LEG

There are no subnet connections for the requested leg type. If the leg type is GTP/RTP leg, check that a valid subnet connection exists in IAKONN. If the leg type is AAL2 leg, check that a valid subnet connec-tion exists in LDFILE.

17072 ANTENNA HOPPING AND E-TRX OR S-TRX CANNOT BE USED SIMULTANEOUSLY IN A BTS

ANTENNA HOPPING AND E-TRX OR S-TRX CANNOT BE USED SIMULTANEOUSLY IN A BTS

17073 MASTER D-CHANNEL DOES NOT EXIST

Master D-channel does not exist.

17074 STATE CHANGE OF SLAVE D-CHANNEL NOT ALLOWED

The state change of the slave D-channel is not allowed. The state change can be done only for the master D-channel.

17075 WRR IS NOT SUPPORTED WITH STATIC CONFIGURATION

Weighted Round Robin is not supported with static configured NSE.

17076 ATTEMPT TO STOP RLC FAILED

Attempt to stop RLC failed.

17077 POSITIVE BIT RATE ALLOCATION FAILED

Positive bit rate allocation failed.

Page 493: DX Error Messages

DN987378Issue 24-0

493

General Error Messages of System DX error messages

Id:0900d8058077e097

17078 PARAMETER FDD RSCP MIN NOT IN USE IN BSC

The RSCP criterion parameters for UTRAN FDD cell reselection algo-rithm are not in use in BSC.

17079 PARAMETER FDD REPORTING THRESHOLD 2 NOT IN USE IN BSC

The RSCP threshold parameter for UTRAN FDD cell reporting is not in usein BSC.

17080 BTS WITH GPRS ENABLED TRX NOT LOCKED IN THE EXTENDED GPRS/EDGE ENABLED CELL

A BTS object with unlocked GPRS Enabled TRX (GTRX=Y) is not locked when Extended Cell for GPRS/EDGE is enabled in the cell (EXGENA=Y).

17081 EXTENDED CELL FOR GPRS/EDGE FEATURE IS NOT IN USE IN THE BSC

The licence of the Extended Cell for GPRS/EDGE application software must exist in the BSC and the licence must be ON-state before activa-tion of the feature.

17082 MAX EGTCH E-TRX CAPACITY LIMIT OF EXTENDED CELL FOR GPRS/EDGE LICENCE EXCEEDED

Capacity limit for Extended Cell for GPRS/EDGE licence is exceeded in BSC, because there are too many EGTCH E-TRXs defined into use in BSC.

17083 BCF SW DOES NOT SUPPORT EXTENDED CELL FOR GPRS/EDGE FEATURE

BCF SW version does not support Extended Cell for GPRS/EDGE feature.

17084 INCORRECT BCF SITE TYPE FOR E-TRX IN EXTENDEDG-PRS/EDGE ENABLED CELL

The BCF site type of the E-TRX must be Nokia UltraSite or Flexi EDGE when Extended Cell for GPRS/EDGE is enabled in the cell (EXGENA=Y).

17085 EGTCH NOT IN GPRS ENABLED TRX

EGTCH channel must be in GPRS Enabled TRX (GTRX=Y).

17086 ALL UNLOCKED TRXS OF THE BTS NOT IN DAP IN EXTENDED GPRS/EDGE ENABLED CELL

All TRXs under a BTS which has GPRS enabled TRX (GTRX=Y) must be added to DAP when Extended Cell for GPRS/EDGE is enabled in the cell (EXGENA=Y).

17087 EGTCHS NOT FILLED ONE AFTER ANOTHER STARTING FROM RTSL-7 IN THE TRX

EGTCHs are not filled one after another starting from RTSL-7 in theTRX.

17088 ALL UNLOCKED TRXS OF THE BTS NOT EDGE TRXS IN EXTENDED GPRS/EDGE ENABLED CELL

Page 494: DX Error Messages

494 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

All unlocked TRXs must have EDGE HW in the BTS when unlocked GPRS Enabled TRX (GTRX=Y) exists in the BTS and Extended Cell GPRS/EDGE parameter is e. nabled in the cell (EXGENA=Y).

17089 DPTRX CAPACITY LICENCE EXCEEDED

TRX capacity of the Double Power TRX for FlexiEDGE BTS licence exceeded. Increase the licence capacity or disable Dual TRX usage (DTRX) of the TRX.

17090 DPTRX LICENCE NOT IN USE IN BSC

Double Power TRX for FlexiEDGE BTS licence is needed in BSC to use Double Power TRX (DPTRX) or Intelligent Downlink Diversity (IDD) fea-tures. Install licence or change the state of the licence to ON or disable Dual TRX usage (DTRX) of the TRX.

17091 NEXT EVEN NUMBERED TRX EXISTS IN THE BCF

Next even numbered TRX exist in the BCF when trying to enable Double Power TRX (DPTRX) or Intelligent Downlink Diversity (IDD) to odd numbered TRX. Use other ID for new TRX or disable Dual TRX usage (DTRX).

17092 DTRX OF ALL TRXS MUST BE EITHER IDD, DPTRX OR DISABLED IN EXTENDED OR SUPER EXTENDED CELL

DTRX OF ALL TRXS MUST BE EITHER IDD, DPTRX OR DISABLED IN EXTENDED OR SUPER EXTENDED CELL

17093 IP BASED ROUTE SET INDEX DOES NOT EXIST

No IP network reference identifier set index or default IP based route identifier set index exists in the virtual MGW files MGDATA, IP2FIL, IP4FIL, and UCUFIL.

17094 TEST LICENCES ARE NOT ALLOWED

The use of test licences is not allowed in this network element.

17095 NODE PIU RESET FAILURE

PIU is already in restart phase.

17096 TOO MANY TRXS UNDER BTS

Too many TRXs under one BTS object.

17097 AMR PPC FEATURE IS NOT IN USE IN BSC

The Progressive AMR Power Control feature is not in use in BSC.

17098 RM3PRB FOUND ERROR IN SP UNIT UPDATING

RM3PRB (DSP Resource Manager) failed to update the spare unit data. The checksum calculated over the working and spare unit data indicates that the spare unit data is not up to date.

17099 THE RELEASE OF THE HANGING LEG IS EXECUTED

RM2 has released the hanging leg resource and the call hand is stopped.

17100 ANSWER MESSAGE CONTAINS REDIRECT REQUEST

The answer message contains a redirect request.

17101 FACCH AND SACCH REPETITION FEATURE IS NOT IN USE IN BSC

Page 495: DX Error Messages

DN987378Issue 24-0

495

General Error Messages of System DX error messages

Id:0900d8058077e097

FACCH and SACCH repetition for repeated ACCH-capable mobiles on AMR feature is not enabled in the BSC. Either the robust AMR signalling feature licence is not valid or the feature is in disabled state.

17102 NONE OF THREE FACCH AND SACCH REPETITION FEATURES IS IN USE IN BSC

None of the three repeated SACCH and FACCH features is enabled in the BSC. This means that the Robust AMR Signalling licence is not valid or one of the following features is in disabled state: "FACCH and SACCH repetition for repeated ACCH capable mobiles on AMR", "FACCH repetition for legacy mobiles on AMR FR", or "FACCH repeti-tion for legacy mobiles on AMR HR".

17103 PCM DOES NOT SUPPORT 64K CHANNELS

PCM does not support 64K channels.

17104 TOO MANY OBJECTS IN RNW PLAN FILE

There are too many objects in the RNW plan file. The RNW Plan Manager program block RAYMAN in the RNC OMU only supports one object in the plan for Direct Activation operation.

17105 OBJECT TYPE IN RNW PLAN FILE IS NOT SUPPORTED

The RNW Plan Manager program block RAYMAN in RNC OMU does not support the RNW object type in Direct Activation.

17106 RNW PLAN DIRECT ACTIVATION OPERATION CANNOT BE ABORTED

RNW Plan Management in the RNC OMU (program block RAYMAN) has rejected the RNW plan operation abort request. The RNW plan direct activation operation cannot be aborted.

17107 ONLY ODD NUMBERED TRX ID ALLOWED FOR DPTRX OR IDD ENABLED TRX

Even numbered ID for Double Power TRX (DPTRX) or Intelligent Downlink Diversity (IDD) enabled TRX cannot be used. Use odd ID for TRX or disable Dual TRX usage (DTRX).

17108 DFCA AND DPTRX OR IDD TRX IN USE IN THE SAME CELL

DFCA cannot be used together with Double Power TRX (DPTRX) or Intelligent Downlink Diversity (IDD) TRX in the same cell. Disable DFCA in the cell or disable Dual TRX usage (DTRX) of the TRX.

17109 TRX ID IS NOT ALLOWED FOR THE SITE TYPE

TRX ID:s 17 - 24 are only allowed for Flexi EDGE BTS TRX ID:s 25 - 32 are only allowed for BTSplus BTS. TRX ID:s 33 - 36 are only allowed for Flexi Multiradio BTS.

17110 POOL ID IN USE

The pool_id is in use and cannot be removed.

17111 IPNWR ALREADY EXISTS

Ipnwr is already in use.

17112 IP BASED ROUTE SET IN USE

The IP based route set is in use and cannot be removed.

Page 496: DX Error Messages

496 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17113 SUM OF PCR OR MCR OF NCIDS INSIDE BUNDLE EXCEEDS THE BUNDLE PCR

The AAL2 path has been rejected because the sum of PCR or MCR inside the bundle exceeds the bundle PCR.

17114 BIOS TIME-OUT

The time limit for the BIOS phase has expired.

17115 FLEX_IU AND MULTIPLE_CN/MULTIOP_RAN CANNOT BE BOTH ON

Multioperator RAN feature and Multi-CN is not supported simultane-ously with FlexIu. If FlexIu is active, the above two features cannot be used.

17116 MAXIMUM NUMBER OF DEFINED CNS EXCEEDED

The maximum number of defined CNs has been exceeded.

17117 MAXIMUM NUMBER OF DEFINED DEFAULT CNS EXCEEDED

The maximum number of defined default CNs has been exceeded.

17118 NUMBER OF CS AND PS CN SHOULD BE EQUAL

The number of CS and PS CN should be equal when FlexIU is acti-vated.

17119 IF NRILENGTHFORCS OR PSCN IS NONZERO,FOR EACH IU OBJ ATLEAST ONE OF THE MIN/MAX SHOULD INDICATE VALID RANGE.

If NRILengthForCS or PSCN is nonzero,for each IU obj atleast one of the min/max should indicate valid range.

17120 NRIMINFORCSCN/PSCN CANNOT BE GREATER THAN NRIMAX-FORCSCN/PSCN

NRIminforCSCN/PSCN cannot be greater than NRImaxforC-SCN/PSCN.

17121 GPRS OR EDGE TRX CAPACITY LICENCE EXCEEDED

GPRS or EDGE TRX capacity licence has been exceeded.

17122 ENABLING THE WPS OPTIONALITY FOR THE RNC IS NOT ALLOWED

It is not allowed to enable the Wireless Priority Service in RNC because optionality Inter System Handover(ISHO) OR Wireless Priority Service is not supported.

17123 ADJGSIB IS NOT ENABLED FOR WPS ADJG IN ONE OR MORE WCEL IN RNC RNW DATABASE

Enabling the Wireless Priority Service in RNC is not allowed because one or more WCELs do not have their Wireless Priority Service Inter System neighb. definition (ADJG id: zero) parameter AdjgSIB enabled.

17124 TOO MANY VPCS IN COCO OBJECT

The RNW plan contains too many VPCs in the COCO object.

17125 IPNWR DOES NOT EXIST

Ipnwr cannot be found in the file.

Page 497: DX Error Messages

DN987378Issue 24-0

497

General Error Messages of System DX error messages

Id:0900d8058077e097

17126 IP BASED ROUTE ID DOES NOT EXIST

The IP based route ID cannot be found.

17127 SET DOES NOT EXIST

The set cannot be found in the file.

17128 DELETION IS NOT ALLOWED

It is not allowed to delete the default IP-based route set.

17129 INTERNAL ADJACENT CELL NOT FOUND

BSC has no corresponding BTS object with the given CGI in the radio network configuration database. The command ZEAR deletes adjacent GSM cell objects with the given CGI only if BSC has a BTS object with the same CGI.

17130 UBR PLUS LICENSE IS NOT ACTIVATED.

If the UBR plus service category is used, the UBR plus license should be activated.

17131 MEMBER(S) STILL LINKED TO GROUP

A link still exists from the member subscriber data to the hunting group.

17132 NO SUCH MEMBER IN GROUP

An attempt has been made to add a member that does not exist.

17133 HUNTING GROUP NOT FOUND

The hunting group or its corresponding member is missing.

17134 CO UNIT CONNECTION FAILURE

The pair unit has lost the connection to the CO unit.

17135 TIMER TO RESET NOT FOUND

Timer to reset not found.

17136 TIMER DELETION FAILED

Timer deletion failed.

17137 TIMER CREATION FAILED

Timer creation failed.

17138 TIMER START FAILED

Starting a timer failed.

17139 IPIF ALREADY EXISTS

The IP interface identifier already exists.

17140 COMMAND NOT ALLOWED ON TRIAL SIDE

The command is not allowed on the trial side.

17141 READING FROM KCS FAILED

Reading from KCS (Keyboard Controller Style) failed.

17142 WRITING TO KCS FAILED

Writing to KCS (Keyboard Controller Style) failed.

17143 SWITCH COMMAND FAILED BECAUSE EQUAL PRIORITY REQUEST IS ACTIVE

Page 498: DX Error Messages

498 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The switch command failed because an equal priority request is already active.

17144 COMMAND TARGETTED TO NON-ATCA UNIT

The command is targeted to a unit outside the ATCA system.

17145 RMCP MESSAGE TIME-OUT

No ACK was received from the BMC for the UDP/RMCP message.

17146 SETTING SYSTEM EVENT LOG TIME FAILED

Setting the system event log time has failed.

17147 SHELF MANAGER DOES NOT SUPPORT IPMI

The shelf manager has support for ASF commands, but no IPMI support.

17148 USED IPMI AUTH TYPE IS NOT SUPPORTED

The used IPMI authentication type is not supported.

17149 IPMI USERNAME IS NOT VALID

The used username is not valid.

17150 NULL USERNAME IS NOT ENABLED

The null username is not enabled.

17151 REQ PRIV LEVEL IS NOT AVAILABLE

Req priv level is not available.

17152 REQ MAX PRIV LEVEL EXCEEDS

The requested max priv level exceeds the user or channel limit.

17153 MAXIMUM NUMBER OF OPEN SESSIONS EXCEEDED

The maximum number of sessions is already open. No new sessions can be opened.

17154 IPMI SESSION SEQUENCE NUMBER IS OUT OF RANGE

The IPMI session sequence number is out of range.

17155 INVALID IPMI SESSION ID IN REQUEST

The request contains an invalid IPMI session ID.

17156 IP INTERFACE DOES NOT EXIST

The IP interface does not exist.

17157 BACKPLANE FAILURE

A failure has occurred in the backplane interface.

17158 BACKPLANE CONNECTION MISMATCH

The backplane cables are not correctly connected.

17159 SET FULL

The IP based route set is full.

17160 MML OVER TELNET AND MML OVER SSH CANNOT BOTH BE DISABLED

MML over telnet or MML over SSH must be enabled. Both cannot be disabled at the same time.

Page 499: DX Error Messages

DN987378Issue 24-0

499

General Error Messages of System DX error messages

Id:0900d8058077e097

17161 IU ITEM NOT FOUND

Iu item cannot be found in the Radio Network Database.

17162 NRI IS SAME AS NULL NRI

The NRI given is already defined as NULL NRI in the PSE.

17163 NSE NRI MASK CHANGES THE PSE NRI MASK TO ZERO

The NSE NRI MASK given changes the PSE NRI MASK to zero, which is not allowed.

17164 NSE NRI MASK CANNOT BE CHANGED.

NSE NRI MASK is different from the one NSE already has, but it cannot be different.

17165 TOO MANY NRI LISTS IN IU_ITEM IN DOWNLOAD PLAN FILE

The iu_item contains too many nri_lists.

17166 CMOB RESTRICTION TYPE CANNOT BE CHANGED.

The CMOB restriction type cannot be changed.

17167 CMOB OBJECT CANNOT BE DELETED IF RELATED WCELS EXIST

A CMOB object cannot be deleted if related WCELs exist.

17168 USER CANNOT CREATE OR DELETE FORCED TYPE CMOB OBJECT.

The user cannot create or delete forced type CMOB objects.

17169 PORT MIRRORING ENABLING FAILED

Port mirroring was not enabled during the configuration.

17170 DYNAMIC HSDPA TRANSPORT SCHEDULING LICENCE IS NOT ACTIVATED

The Dynamic HSDPA Transport Scheduling feature should be activated before use.

17171 DYNAMIC SCHEDULING FOR HSDPA LICENCE LIMIT IS EXCEEDED

The total number of Dynamic scheduling for HSDPA enabled COCO objects exceeds the maximum optional value.

17172 DYNAMIC SCHEDULING FOR NRT DCH LICENCE LIMIT IS EXCEEDED

The total number of dynamic scheduling for NRT DCH enabled COCO objects exceeds the maximum optional value.

17173 FLOW CONTROL METHOD DOES NOT MATCH FOR BUNDLE USAGE

In order to enable bundle, either HSDPA flow control or NRT DCH flow control should be used.

17174 HSDPA VCC IS MISSING FROM COCO IN WHICH BUNDLE IS USED

HSDPA VCC should be configured in the COCO in which the Bundle is used.

17175 CMOB STILL USED BY SOME WCEL

CMOB cannot be deleted because it is still used by some WCEL.

Page 500: DX Error Messages

500 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17176 CMOB TYPE AND USAGE DO NOT MATCH IN WCEL

CMOB type and usage do not match in WCEL.

17177 CIRCUIT ALREADY IN REMOTE TDM USE

The virtual circuit is already reserved for a remote TDM.

17178 RNAR CMOB COUNT TOO HIGH

The RNAR CMOB count must not exceed 2.

17179 CS DSAC CMOB COUNT TOO HIGH

The CS DSAC CMOB count must not exceed 4.

17180 PS DSAC CMOB COUNT TOO HIGH

The PS DSAC CMOB count must not exceed 4.

17181 WRONG INTERFACE TYPE FOR REMOTE TDM

Wrong interface type for remote TDM.

17182 TARGET SERVICE TYPE NOT SUPPORTED IN THE SERVICE POOL

The target service type specified in a DSP resource modification request is not supported in the service pool.

17183 PCU DOES NOT HAVE FEATURE BITMAP(S)

PCU does not have feature bitmap(s) when requested.

17184 HSDPA VCC IN A BUNDLE DOES NOT MATCH FOR HSDPA FLOW CONTROL METHOD

HSDPA flow control is requested in order to attach HSDPA VCC in a bundle.

17185 NRT DCH VCC IN A BUNDLE DOES NOT MATCH FOR NRT DCH FLOW CONTROL METHOD

NRT DCH flow control is requested in order to attach NRT DCH VCC in a bundle.

17186 SHARED VCC CAN NEVER BE ATTACHED IN A BUNDLE

SHARED VCC can never be attached in a bundle.

17187 PATH TYPE OF VCC ATTACHED IN A BUNDLE DOES NOT MATCH FOR BUNDLE USAGE

Tolerant RT DCH, NRT DCH, and DCH cannot be in a bundle.

17188 SERVICE CATEGORY OF VCC ATTACHED IN A BUNDLE DOES NOT MATCH FOR BUNDLE USAGE

NRT, HSDPA, HSPA, and HSUPA VCC attached in a bundle must use UBR+. RT DCH and DCH VCC can use either CBR or UBR+.

17189 BUNDLE USAGE DOES NOT MATCH FOR FLOW CONTROL METHOD

In order to enable bundle, either HSDPA flow control or NRT DCH flow control should be used.

17190 MARKET EXPANSION TOOLKIT FEATURE NOT IN USE IN BSC

The Market Expansion Toolkit feature is not in use in BSC.

Page 501: DX Error Messages

DN987378Issue 24-0

501

General Error Messages of System DX error messages

Id:0900d8058077e097

17191 DISABLING UL PWR CONTROL FOR EMERGENCY CALLS FEATURE NOT IN USE IN BSC

Disabling uplink power control for emergency calls due to U-TDOA (Uplink Time Difference Of Arrival) positioning feature not in use in BSC (Base Station Controller).

17192 BLER WINDOW EDPCH CALCULATION LENGTH EXCEEDS THE LIMIT

The length of the BLER Window EDPCH Calculation cannot exceed the OLPC Entity reporting period.

17193 INTERDEPENDENCE BETWEEN DELAYTHRESHOLDMIN, DELAY-THRESHOLDMID AND DELAYTHRESHOLDMAX ERROR

The value of Middle Threshold value for HSUPA congestion delay always has to be greater than the value of Minimum Threshold value for HSUPA congestion delay and less than the value of Maximum Thresh-old value for HSUPA congestion delay.

17194 INTERDEPENDENCE BETWEEN HSUPA ENABLED AND HSDPA ENABLED ERROR

If the parameter HSUPA Enabled of WCEL is enabled, the parameter HSDPA Enabled of WCEL must be enabled as well. Likewise, if the parameter HSDPA Enabled of WCEL is disabled, the parameter HSUPA Enabled of WCEL must be disabled as well.

17195 THE NUMBER OF HSUPA ENABLED BTS EXCEEDS THE LIMIT.

The maximum number of HSUPA enabled BTSs cannot exceed the maximum number in RNC specified by the Basic HSUPA BTS licence.

17196 HSDPA DYNAMIC RESOURCE ALLOCATION NOT ENABLED

HSUPA can be enabled only when HSDPA dynamic resource allocation is enabled.

17197 THE HSUPA STATE OF WCELS WITH SAME UARFCN INCONSIS-TENCY

If HSUPA is activated, it must be activated in all cells that use the same frequency (UARFCN) in the same BTS. If HSUPA is deactivated, it must be deactivated in all cells that use the same frequency (UARFCN) in the same BTS.

17198 NUMBEREDCHRESERVEDSHOBRANCHADDITIONS GREATER THAN MAXNUMBEREDCHLCG OR MAXNUMBEREDCHCELL

The value of Number of E-DCHs reserved for SHO branch additions (NumberEDCHReservedSHOBranchAdditions) must be lower than the values of Maximum number of E-DCHs in the cell (MaxNumberEDCH-Cell) and Maximum number of E-DCHs in the local cell group (MaxNum-berEDCHLCG).

17199 INTERFERENCE MARGIN FOR MIN EDCH LOAD GREATER THAN MAX TARGET RECEIVED WIDE BAND POWER

The value of Interference margin for the minimum E-DCH load must be lower than or equal to the value of Maximum target received wide band power for BTS.

Page 502: DX Error Messages

502 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17200 HSPA FMCS IDENTIFIER NOT DEFINED

If the parameters HSUPA enabled and HSDPA enabled are enabled, the HSPA FMCS identifier must be defined.

17201 MIN PS TARGET INTERFERENCE SHARING BIGGER THAN MAX PS TARGET INTERFERENCE SHARING

The value of Min PS target in HSPA-DCH interference sharing must be less than or equal to the value of Max PS target in HSPA-DCH interfer-ence sharing.

17202 INTERFERENCE MARGIN FOR THE MIN UL DCH LOAD GREATER THAN THE MAX VALUE

The value of Interference margin for the minimum UL DCH load must be less than or equal to the value of Interference margin for the maximum UL DCH load.

17203 CHECK FOR CPICH ECNO OFFSET E-DCH USAGE REMOVAL AND ALLOW E-DCH USAGE ECNO OFFSET ERROR

In order to avoid frequent channel type switches between DCH and E-DCH, the value of CPICH EcNo offset E-DCH usage removal should be at least 2 dB higher than that of Allow E-DCH usage EcNo offset.

17204 INTERDEPENDENCE BETWEEN EDCHREMECNOOFFSET AND HSDPASERVCELLWINDOW ERROR

CPICH EcNo offset E-DCH usage removal (EDCHRemEcNoOffset) cannot have a value that is 0.5-1.5 dB lower than that of CPICH Ec/No window for serving HS-DSCH cell selection (HSDPAServCellWindow, defined in RNC).

17205 THE LICENCE STATE OF BASIC HSUPA BTS ERROR

If the state of the Basic HSUPA BTS licence is CONFIG or OFF, the parameter HSUPA Enabled cannot be enabled.

17207 PAPU TO BE ADDED TO GROUP CANNOT HAVE D-UMA RAI

The PAPU to be added to the PAPU group cannot have d-uma rai.

17208 SCTP ASSOCIATION EXISTS

PAPU cannot be removed from the PAPU group if it has an SCTP asso-ciation configured.

17209 NSVC WAS NOT FOUND IN GBC TABLE

NS_VC was not found in the GBC table.

17210 NSE NOT FOUND IN GBC TABLE

NSE was not found in the GBC table.

17211 OBJECT WAS NOT FOUND IN FILE

The object was not found in the file.

17212 NSE IS DYNAMIC

NSE is dynamic.

17213 HSPA FMCS NOT FOUND

The High-speed Packet Access (HSPA) Intra-Frequency Measurement Control (FMCS) object cannot be found in the Radio Network Database.

Page 503: DX Error Messages

DN987378Issue 24-0

503

General Error Messages of System DX error messages

Id:0900d8058077e097

17214 RT HSPA FMCS NOT FOUND

The High-speed Packet Access (HSPA) Intra-Frequency Measurement Control (FMCS) object for AMR multi-service cannot be found in the Radio Network Database.

17215 DSP RESOURCE STATISTICS CORRUPT

The counters used to measure DSP performance statistics (either for internal use or for Common Statistics measurements) have overflowed or underflowed.

17216 CABINET DOES NOT EXIST

The cabinet does not exist in the equipment database. Therefore it cannot be deleted and no subrack can be created for it.

17217 CABINET ALREADY EXISTS

The cabinet cannot be created in the equipment database because it already exists.

17218 HSPA FMCS IDENTIFIER FOR AMR MULTI-SERVICE NOT DEFINED

The value of the parameter HSPA FMCS identifier in WCEL for AMR multi-service must be set if the licence HSUPA with Simultaneous AMR Voice Call is supported and the parameters HUSPA Enabled in WCEL and Usage of AMR service with E-DCH In RNC are enabled.

17219 AMRWITHEDCH IS VALID ONLY IF AMRWITHHSDSCH IS ENABLED

AMRWithEDCH is valid only if AMRWithHSDSCH is enabled.

17220 LAST DEFAULT ANALYSIS

Handling of the last default analysis. If the last default analysis is deleted, this means that there are no more default results at this point in the analysis chain.

17221 SET CANNOT BE DELETED BECAUSE IT BELONGS TO A PROTEC-TION GROUP

The SET to be deleted belongs to a protection group. Delete the protec-tion group first.

17222 UNKNOWN PARAMETER FOR CMOB IN RNW PLAN

The parameter in RNW plan is unknown to the plan interface.

17223 UNKNOWN FRU MODULE TYPE

The FRU module type is unknown.

17224 VERSION OF THE FRU DATA IS WRONG

The version of the FRU data is wrong.

17225 REJECTED DUE TO LACK OF BANDWITH. ALLOCATION CAN BE RETRIED

The allocation was rejected due to a lack of bandwidth or because the delay requirements on NCID tp are too strict. Try again from another AAL Type 2 path on the route.

17226 NO USERS FOR THE CONFIGURATION DATA

No processes have subscribed to this configuration data. This could mean that, for example, no computer units that provide the services you

Page 504: DX Error Messages

504 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

are trying to configure exist in the current hardware configuration, or that a restart has occurred and processes interested in the configuration data have not subscribed to it yet.

17227 IUV HAS NOT MODIFIED THE IU LIST

IUV has not modified the IU_LIST due to Active CN.

17228 DSP RESOURCE OF THE LEG IS NOT SEIZED

The DSP resource of the leg is not seized even though it is needed for the requested service.

17229 SHARED VCC IS MISSING FROM CONNECTION CONFIGURATION OBJECT

SHARED VCC is missing in the COCO object when non-HSDPA dedi-cated route selection is used. In non-HSDPA dedicated route selection, DCH and SHARED VCCs can be configured.

17230 BUNDLE ITEM IS MISSING IN COCO BUNDLE LIST

One bundle item is referred to by AAL2TP, but there is no correspond-ing bundle parameter defined.

17231 UBR+ SERVICE CATEGORY CANNOT EXIST WITH HSDPA FLOW CONTROL IF BUNDLE IS NOT USED

The UBR+ service category cannot be defined for a COCO link with dynamic HSDPA flow control if bundle is not used.

17232 ALL DCH SHOULD BE INSIDE SAME BUNDLE OR OUTSIDE OF BUNDLE

When VCC bundle is used, all VCCs carrying DCH traffic (RTDCH, NRTDCH, and DCH VCCs) must be inside the same bundle or outside of bundle.

17233 PORT ALREADY RESERVED

The given port number is already reserved in the ATM card.

17234 ADMINISTRATIVE STATE NOT LOCKED

The requested operation cannot be performed because the administra-tive state is not locked.

17235 SDH/SONET IDENTIFIER DOES NOT EXIST

The specified SDH/SONET identifier does not exist.

17236 ADMINISTRATIVE STATE ALREADY SET

The administrative state has already been set to the requested state.

17237 PHYTTP IS IN USE

phyTTP is in use.

17238 PHYTTP IS ALREADY IN USE

phyTTP is already in use.

17239 ATM INTERFACE EXISTS ALREADY

The specified ATM interface identifier exists already.

17240 SUM OF PCR EXCEEDED IN VP

The sum of PCR exceeds the given PCR for VP.

Page 505: DX Error Messages

DN987378Issue 24-0

505

General Error Messages of System DX error messages

Id:0900d8058077e097

17241 USAGE ALREADY EXISTS

Usage already exists in VP/VC.

17242 INTERNAL STORAGE EXCEEDED

The internal storage capacity has been exceeded. No more new data can be saved.

17243 FALLBACK ACTIVATION IS THE ONLY POSSIBLE OPERATION IN THIS STATE

Fallback activation is the only possible FBPP operation in INTERRUPTED_BY_SYSTEM state.

17244 RNW FALLBACK CONFIGURATION IS MISSING

No RNW fallback configuration exists.

17245 UNKNOWN SUBSCRIBER IN EXTERNAL DATABASE

The subscriber is unknown in the external database.

17246 SUBSCRIBER ALREADY EXISTS IN EXTERNAL DATABASE

The subscriber already exists in the external database.

17247 INCONSISTENT DATA FROM EXTERNAL DATABASE

Inconsistent data from external database.

17248 AUTHENTICATION TO EXTERNAL DATABASE FAILED

Authentication to external database failed.

17249 NO CONNECTION TO EXTERNAL DATABASE

No connection to external database.

17250 ERROR OCCURRED IN EXTERNAL DATABASE

Error occurred in external database.

17251 NSVC RELATED TO UNIT

A unit cannot be removed from a PAPU group if NSVC is related to it.

17252 MISSING NRT VCC FOR DYNAMIC NRT PATH SELECTION

NRT VCC is missing in COCO while dynamic NRT flow control is enabled.

17253 DEVICE IS REMOVED

This error code is related to the hotswap feature. It is returned when an attempt is made to access a removed PCI device.

17254 PCM IS IN ATER USE

PCM is in Ater use.

17255 APP650 API ERROR

APP650 API returned an error.

17256 PCM IS FAULTY

PCM has been found faulty by PCM supervision.

17257 ERROR OCCURS WHEN DECODING DATA FROM BS_OM_RELAY_S MESSAGE

RAKTOR cannot decode the data in the bs_om_relay_s message sent by BOIMED.

Page 506: DX Error Messages

506 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17258 NO RESPONSE FOR QUERYING INFORMATION OF THE A2SP UNIT WHERE END POINT EXISTS FROM UHAPRB

UHAPRB should return an atm_xconn_inquiry_ack_s message to VEXELI on time.

17259 RNC GUI FOR BTS CONNECTION RESOURCES LICENCE IS NOT ACTIVATED

The RNC GUI for BTS Connection Resources licence should be acti-vated.

17260 THE WBTS HAS NOT BEEN MONITORED IN VEXELI

The GUI can get this WBTS connection resource information only after one monitoring hand has been created in VEXELI for this WBTS.

17261 NO RESPONSE FOR NRM_CELL_RES_AS SERVICE FROM NRMPRB

NRMPRB should return an nrm_get_cell_conn_res_ack_s message to VEXELI on time.

17262 THE SHAPE PRIORITY MUST BE UNIQUE UNDER CIRTTSHAPE PRIORITY LIST

The shape priority value must be unique within non_emg_shape_list and emg_shape_list under wsmlc.

17263 IPQM NOT FOUND

The IPQM object that defines the UMTS traffic class to DSCP mapping to be used for the IP connections at the Iu interface was not found in the Radio Network Database.

17264 NSE HAS NO NRI CONFIGURED

Each NSE of PSE/PCU must have at least one NRI in NS-VL/NSE creation when Multipoint Gb is going to be taken into use.

17265 BOTH CABLE AND EQUIPMENT PROTECTION IN THE SAME UNIT IS NOT ALLOWED

It is not possible to configure both cable and equipment protection in the same STM-1/OC-3 interface unit pair.

17266 PAPU IS NOT IN GROUP

The given PAPU does not belong to the PAPU Group.

17267 ANOTHER PAPU IS BLOCKED IN GROUP

Another PAPU unit is already blocked for maintenance. Only one PAPU per group can be blocked at the same time.

17268 MASS DETACH IS ACTIVE

Mass Detach is active.

17269 NO RESPONSE FROM YYYPRB

YYYPRB did not respond to a request message.

17270 IPQM ALREADY CREATED

The IPQM object which defines the UMTS traffic class to DSCP mapping tobe used for the IP connections at the IU interface was not found in the Radio Network Database.

Page 507: DX Error Messages

DN987378Issue 24-0

507

General Error Messages of System DX error messages

Id:0900d8058077e097

17271 IPQM COLLECTION FULL

There is no room for a new IPQM object in the radio network database.

17272 USE OF NORMAL AREA NON-BCCH PGSM TRX DENIED IN EGSM RF HOPPING BTS WHEN BCCH TRX IS PGSM

Use of normal area non-BCCH PGSM TRX is denied in RF hopping BTS with EGSM900 frequency and PGSM frequency BCCH TRX.

17273 PGSM & EGSM FREQS IN MA LIST WITHOUT SINGLE MA FOR PGSM & EGSM LICENCE

PGSM900 and EGSM900 frequencies can occur in the same MA list only if the state of the Single MA for PGSM and EGSM licence is ON.

17274 NO RESPONSE FROM ATYPRB FOR AAL2 PATH LOAD INFORMA-TION MONITORING REQUEST

No response from ATYPRB for AAL2 path load information monitoring request.

17275 NO RESPONSE IN QUERYING STATE OF VCCEP FROM THE DYNAMIC ROUTING STRUCTURES FROM BRADMI

VEXELI cannot get the BRADMI service in querying state of the end-points from the dynamic routing structures.

17276 NO RESPONSE FOR QUERYING OPERATIONAL STATES OF AAL2 SIGNALLING LINKS FROM MAGPRB

MAGPRB should return an aal2_op_state_resp_s message to VEXELI after some time.

17277 SPARE 2 FOR S12

Spare 2 DX error code for S release use.

17278 SPARE 3 FOR S12

Spare 3 DX error code for S release use.

17279 SPARE 4 FOR S12

Spare 4 DX error code for S release use.

17280 SPARE 5 FOR S12

Spare 5 DX error code for S release use.

17281 SPARE 6 FOR S12

Spare 6 DX error code for S release use.

17282 TD-SCDMA IW OPTION IS NOT IN USE IN BSC

The TD-SCDMA interworking option is not in use in BSC.

17283 TOO MANY BUNDLE PARAMETERS IN VCCBUNDLELIST

VccBundleList contains too many bundle parameters.

17284 EMERGENCY CALL REDIRECT TO GSM LICENCE STATE CON-FIG/OFF, NOT ON

EmergencyCallRedirect cannot be enabled because the state of the Emergency Call Redirect to GSM licence is CONFIG/OFF, not ON.

17285 BASIC HSDPA WITH QPSK AND 5 CODES LICENCE STATE CON-FIG/OFF, NOT ON

Page 508: DX Error Messages

508 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

HSDPA cannot be activated in the WCEL because the state of the HSDPA with QPSK and 5 Codes licence is CONFIG/OFF, not ON.

17286 HSDPA SERVING CELL CHANGE AND SOFT/SOFTER HO LICENCE STATE CONFIG/OFF, NOT ON

HSDPAMobility cannot be activated because the state of the HSDPA Serving Cell Change and Soft/Softer HO licence is CONFIG/OFF, not ON.

17287 HSDPA WITH SIMULTANEOUS AMR VOICE CALL LICENCE STATE CONFIG/OFF, NOT ON

AMRWithHSDSCH cannot be activated because the state of the HSDPA with Simultaneous AMR Voice Call licence is CONFIG/OFF, not ON.

17288 HSDPA DYNAMIC RESOURCE ALLOCATION LICENCE STATE CONFIG/OFF, NOT ON

HSDPADynamicResourceAllocation can only be activated if the state of thet HSDPA Dynamic Resource Allocation licence is ON. However, the state of the licence is CONFIG/OFF.

17289 HSDPA 10 CODES LICENCE STATE CONFIG/OFF, NOT ON

HSDPA10Codes can only be activated for the WCEL if the state of the HSDPA 10 Codes licence is ON. However, the state of the licence is CONFIG/OFF.

17290 HSDPA 15 CODES LICENCE STATE CONFIG/OFF, NOT ON

HSDPA15Codes cannot be activated for the WCEL because the state of the HSDPA 15 Codes licence is CONFIG/OFF, not ON.

17291 16 KBIT/S RETURN CHANNEL DCH DATA RATE SUPPORT FOR HSDPA LICENCE STATE CONFIG/OFF, NOT ON

HSDPA16KBPSReturnChannel cannot be activated because the state of the 16 kbit/s Return Channel DCH Data Rate Support for HSDPA licence is CONFIG/OFF, not ON.

17292 HSDPA CODE MULTIPLEXING LICENCE STATE CONFIG/OFF, NOT ON

HSDPA code multiplexing cannot be activated for the WCEL because the state of the HSDPA code multiplexing licence is CONFIG/OFF instead of ON.

17293 NEEDED EXTENDED CELL RANGE LICENCE STATE CONFIG/OFF, NOT ON

CellRange exceeds the maximum limit because the needed extended cell range licence state is CONFIG/OFF instead of ON.

17294 HSDPA 48 USERS PER CELL LICENCE STATE CONFIG/OFF, NOT ON

HSDPA48UsersEnabled cannot be activated because the state of the HSDPA 48 Users per Cell licence is CONFIG/OFF, not ON.

17295 HSDPA LAYERING FOR UES IN COMMON CHANNELS LICENCE STATE CONFIG/OFF, NOT ON

Page 509: DX Error Messages

DN987378Issue 24-0

509

General Error Messages of System DX error messages

Id:0900d8058077e097

HSDPALayeringCommonChEnabled cannot be activated for the WCEL, because HSDPA Layering for UEs in Common Channels licence state is CONFIG/OFF, not ON.

17296 HSUPA WITH SIMULTANEOUS AMR VOICE CALL LICENCE STATE CONFIG/OFF, NOT ON

The state of the HSUPA with simultaneous AMR voice call licence is CONFIG/OFF, not ON. Therefore AMRWithEDCH cannot be activated.

17297 FLEXIBLE IU LICENCE STATE CONFIG/OFF, NOT ON

IuFlex cannot be activated for either of IU-CS or IU-PS, because the Flexible Iu licence state is CONFIG/OFF instead of ON.

17298 MUX SERVICE RESERVATION FAILED

MUX service reservation failed.

17299 MAX BITRATE EXCEEDED

The maximum bitrate has been exceeded.

17300 TOO MANY VIDEO TRACKS IN 3GP FILE

The 3GP file contains too many video tracks.

17301 TOO MANY AUDIO TRACKS IN 3GP FILE

The 3GP file contains too many audio tracks.

17302 WRONG VIDEO CODEC

Wrong video codec.

17303 WRONG AUDIO CODEC

Wrong audio codec.

17304 H.223 MOBILE LEVEL DETECTION FAILED

H.223 Mobile Level Detection failed.

17305 H.245 TERMINAL CAPABILITY EXCHANGE FAILED

H.245 Terminal Capability Exchange failed.

17306 H.245 MASTER SLAVE DETERMINATION FAILED

H.245 MASTER SLAVE DETERMINATION FAILED

17307 H.245 OPEN LOGICAL CHANNELS FAILED

H.245 OPEN LOGICAL CHANNELS failed.

17308 H.245 MULTIPLEX TABLE ENTRIES FAILED

H.245 Multiplex table entries failed.

17309 APCM IS IN REMOTE TDM USE

APCM is reserved for remote TDM.

17310 NO FREE PORTS FOR SEMIPERMANENT CONNECTIONS

There are no free ports for semipermanent TDM-IP or remote TDM con-nections.

17311 PHYTTP IS IN DETACHED STATE

phyTTP is in detached state. The phyTTP is detached if the interface unit that contains it is removed with conditional removing or if phyTTP is detached from the interface unit with an MML command.

Page 510: DX Error Messages

510 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17312 PROTECTION GROUP IS IN DETACHED STATE.

The protection group is detached if the interface unit that contains the protection group is removed with conditional removing or if the phyTTP that contains the protection group is detached from the interface unit with an MML command.

17313 PHYTTP STILL EXISTS IN GIVEN UNIT

A physical layer logical object still exists in the unit. Therefore it is not safe to remove the unit, unless the interface unit supports attaching and detaching of phyTTP.

17314 PROTECTION GROUP STILL EXISTS IN GIVEN UNIT

A physical layer logical object still exists in the unit; therefore it is not safe to remove the unit unless attaching and detaching of phyTTP is supported in the interface unit.

17315 PAPU IS NOT BLOCKED

Mass Detach cannot be performed if the PAPU is not in blocked state.

17316 IMA GROUP STILL EXISTS IN GIVEN UNIT

An IMA group still exists in the given unit. Therefore the unit cannot be safely removed.

17317 THE RELATED INTERFACE UNIT TYPE IS NOT SUPPORTED FOR THE OPERATION

The related interface unit does not support moving of phyTTP or the phyTTP base (for example, phyTTP based on SET or phyTTP based on Protection group). Therefore detaching or attaching of phyTTP is not supported.

17318 MAPPING MODE IS NOT SUPPORTED

The operation cannot be executed because mapping mode is not sup-ported.

17319 MODIFICATION OF SDH PARAMETERS OF PROTECTION GROUP IS NOT ALLOWED

The SDH parameters of SET in the protection group cannot be modified because the other SET of the protection group is missing.

17320 ATTACHING OF PHYTTP FAILED BECAUSE DETACHED PHYTTP HAS A PROTECTION GROUP

The detached phyTTP cannot be attached to a new protection group because it already has a protection group.

17321 PHYTTP NOT IN DETACHED STATE

An attempt was made to attach phyTTP. However, phyTTP is not in detached state, or it is not of a type that can be attached.

17322 MDSNMP TIME-OUT

MDSNMP is not responding. The owner of the error message is AYSNMP.

17323 SET INDEXES CANNOT FORM PROTECTION GROUP

Set indexes cannot form a protection group. For unit protection, they must belong to pair network interface units. For fibre protection, they

Page 511: DX Error Messages

DN987378Issue 24-0

511

General Error Messages of System DX error messages

Id:0900d8058077e097

must belong to the same network interface units. For NPS1P network interface units, the internal index of SET between pair units must be the same.

17324 OPERATION DID NOT SUCCEED COMPLETELY

The requested operation did not succeed completely.

17325 IPV4 ADDRESS NOT CONFIGURED FOR INTER-PCU LAN

IPv4 address is not configured for Inter-PCU LAN in PCU2.

17326 KEY CURRENTLY USED BY SSL/TLS PROTOCOL LAYER

The key is currently being used by the SSL/TLS protocol layer.

17327 AUC SUBSCRIBER DOES NOT EXIST

The authentication data of the subscriber does not exist.

17328 THRESHOLDMAXEDPDCHSR1920KBPS MUST BE GREATER THAN THRESHOLDMAXEDPDCHSR960KBPS

ThresholdMaxEDPDCHSR1920kbps must be greater than ThresholdMaxEDPDCHSR960kbps.

17329 REUSABLE SDH PARAMETERS NOT FOUND

No reusable SDH parameters were found. This probably means that the work file for reusable SDH parameters is missing.

17330 NETWORK INTERFACE UNIT NOT IN SE STATE

When detaching or attaching phyTTP, the network interface unit must be in SE state. When dealing with protected network interface units, both must be in SE state if both of them exist.

17331 ILDATA DATABASE COULD NOT BE READ

The ILDATA database could not be read.

17332 UPDATING OF ILDATA DATABASE FAILED

Updating of ILDATA database failed.

17333 SUPERVISING UNIT OF LAN SWITCH DOES NOT EXIST IN INTERNAL LAN CONFIGURATION

The supervising unit of the LAN switch does not exist in the internal LAN configuration. A LAN switch can only be added if it has a supervising unit in the internal LAN configuration.

17334 DIFFERENT VALUES ARE CONFIGURED FOR THE SAME PARAM-ETER IN VCC OF COCO AAL2 UP PLANE

The same parameter in VCC of COCO AAL2 UP plane should have the same value.

17335 DIRECT RESOURCE ALLOCATION LICENCE STATE CONFIG/OFF, NOT ON

RABDRAEnabled cannot be activated because the direct resource allo-cation state is config/off instead of on.

17336 WARMING NOT POSSIBLE, NO PCB

Warming is not possible because there is no PCB.

17337 WARMING NOT POSSIBLE, PROCESS RUNNING

Page 512: DX Error Messages

512 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

Warming is not possible because there is a running process.

17338 WARMING NOT POSSIBLE, WARMING BIT NOT OK

Warming is not possible because the warming bit is not OK.

17339 WARMING NOT POSSIBLE, NOT IN MAIN RECEIVE

Warming is not possible. The process is not in main receive.

17340 WARMING NOT POSSIBLE, HAND IS INVALID

Warming is not possible due to an invalid hand.

17341 WARMING NOT POSSIBLE, HAND IS DEAD

Warming is not possible because the hand is dead.

17342 WARMING NOT POSSIBLE, MESSAGES IN SAVE

Warming is not possible because there are messages in save.

17343 WARMING NOT POSSIBLE, MESSAGES IN QUEUE

Warming is not possible because there are queued messages.

17344 SHELF MANAGER FIRMWARE UPDATE IS NOT READY

The shelf manager firmware update is not ready and IPMI commands cannot therefore be forwarded to the current unit.

17345 NO PARAMETERS IN REQUEST

The object modification message is empty.

17346 MANDATORY PARAMETER MISSING

A mandatory parameter is missing in the requested operation.

17347 DEFINED CIRTT SHAPE PRIORITIES ARE NOT DESCENDING FROM THE HIGHEST PRIORITY WITHOUT GAPS

The selected shape priorities in the list (CIRTTShapelist, CIRTTEmer-gencyShapelist) are not descending from the highest priority without gaps.

17348 THE CIRTT SHAPE PRIORITY LIST SHOULD NOT BE EMPTY

The CIRTT shape priority list (CIRTTShapeList, CIRTTEmergency-ShapeList) should not be empty.

17349 HSPA INTERRNC HHO LICENCE IS NOT ACTIVATED

The HSPA Inter-RNC HHO licence is not activated.

17350 NS-VL CREATION FAILED AS SGSN DOES NOT RESPOND

NS-VL creation failed as SGSN does not respond.

17351 SINGLE SET IN PROTECTION GROUP NOT ALLOWED

It is not allowed to create a protection group or attach a phyTTP to a pro-tection group with only a single SET.

17352 SERVICE TERMINAL CONNECTION IS IN USE

The configuration cannot be changed while a service terminal connec-tion is open. Close the service terminal connection before attempting to change the configuration again.

17353 DSP DID NOT START UP

Page 513: DX Error Messages

DN987378Issue 24-0

513

General Error Messages of System DX error messages

Id:0900d8058077e097

The DSP did not start up after the code image was loaded into its memory.

17354 DSP DID NOT INITIATE BOOT SEQUENCE

The DSP did not send a boot request to the OMU after it was released from reset.

17355 SPONTANEOUS DSP RESTART DETECTED

The DSP unexpectedly sent a boot or init request to the OMU. This indi-cates that it was spontaneously restarted.

17356 SECONDARY PLMN ID MUST BE UNIQUE UNDER A CERTAIN PRIMARY PLMN ID

Each secondary PLMN ID must be unique within all CNs with the same primary PLMN ID.

17357 CELL ALREADY HAS ADJACENT TD-SCDMA CELL WITH THE SAME UARFCN AND CELL PARAMETER VALUE PAIR

The same frequency and cell parameter combination is already being used by another adjacent TD-SCDMA cell of the serving GSM cell. It is not allowed to define several adjacent TD-SCDMA cells with the same frequency (UARFCN) and Cell parameter code combination for the serving GSM cell.

17358 CONNECTION TO SHELF MANAGER IS NOT READY

The connection to the shelf manager is not ready for for RMCP messag-ing.

17359 UNIT TO BE MOVED IS ALREADY IN TARGET SLICE

The unit to be moved is already in the target slice.

17360 MDSNMP TIME OUT

MDSNMP is not responding. The owner of the error message is AYSNMP.

17361 MULTIPOINT OFFLOAD PHASE CONFLICT

A phase conflict occurred when trying the set new phase. Every PAPU should be in the same phase when modifying several PAPUs at the same time.

17362 MULTIPOINT OFFLOAD IS ACTIVE

Multipoint offload is active. This error occurs mainly when an attempt is made to set offload automode while offload is active in the same PAPU, or to set PAPU Blocking / Mass Detach at the same time.

17363 PAPU BLOCKING FOR MAINTENANCE IS ACTIVE

PAPU Blocking for Maintenance is active. Multipoint Offload and PAPU Blocking cannot be on simultaneously.

17364 BCCH ARFCN OF ADJG IS NOT COMPATIBLE WITH BAND INDICA-TION

The BCCH ARFCN of the object ADJG is not compatible with the band indicator.

17365 RF HOP CANNOT BE USED FOR A PGSM EGSM BTS WITH PGSM BCCH WITHOUT CORRECT LICENCE

Page 514: DX Error Messages

514 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The use of RF hopping is not allowed in a BTS that has PGSM900 and EGSM900 frequencies in use and BCCH on PSGM900 if the state of the Single MA for EGSM and PGSM licence is not ON.

17366 PGSM AND EGSM FREQUENCIES CANNOT BE IN SAME MA LIST WITHOUT CORRECT LICENCE

PGSM900 and EGSM900 frequency cannot appear in the same Mobile Allocation frequency list unless the state of the Single MA for EGSM and PGSM licence is ON.

17367 IP INTERFACE IS USED BY APPLICATION

The IP interface is being used by an application.

17368 PROTECTION GROUP ALREADY EXISTS

The protection group already exists.

17369 SDH/SONET PROTECTING SECTION HAS ATM INTERFACE

The SDH/SONET which is used as protecting section has an ATM inter-face.

17370 INCORRECT PORT PAIR FOR SDH/SONET PROTECTION GROUP

Incorrect port pair for SDH/SONET protection group.

17371 WORKING AND PROTECTING SDH/SONET INTERFACE MUST BE IN SAME UNIT

The working and the protecting SDH/SONET interface must be in the same unit.

17372 PHYSICAL SDH PORT ALREADY RESERVED

The software attempted to reserve a physical SDH port that is already reserved.

17373 INVALID SLOT REQUESTED

The PCI driver returns this error if an attempt is made to access an invalid slot.

17374 CREATION OF ATM INTERFACE FOR PROTECTING SDH/SONET INTERFACE IS NOT ALLOWED

The creation of an ATM interface for protecting the SDH/SONET inter-face is not allowed.

17375 REQUESTED SERVICE IS NOT YET INITIALIZED

The requested service is not initialised yet.

17376 PHYTTP BASE CONFLICT IN ATTACH OPERATION

It is not possible to attach phyTTP because the base of the detached phyTTP conflicts with the attaching parameters given. To attach a SET-based phyTTP to a protection group, create a new protection group. To attach a protection-group-based phyTTP to a SET phyTTP, delete the old protection group first.

17377 ONLY ONE ADJACENT UTRAN CELL TYPE CAN BE USED FOR A SEGMENT AT THE SAME TIME

Page 515: DX Error Messages

DN987378Issue 24-0

515

General Error Messages of System DX error messages

Id:0900d8058077e097

A segment can have only one type of adjacent UTRAN cells at the same time. It is not possible to add an adjacent TD-SCDMA RAN cell to a segment that already has an adjacent WCDMA RAN cell.

17378 NO OPERATION, TARGET UNIT OR SYSTEM HAS CBAN STATUS

No operation, target unit, or system has CBAN status.

17379 UNLOCKED WCELS EXCEED THE LICENSED CAPACITY

Unlocked WCELs exceed the licensed capacity.

17380 SUM OF VCC PCR IS GREATER THAN VP PCR IN ONE COCO

The sum of VCC PCR is greater than VP PCR in one COCO.

17381 PARAMETERS CANNOT BE BOTH ENABLED

If this DirectedRRCForHSDPALayerEnhanc is disabled, Directe-dRRCEnabled and DirectedRRCForHSDPALayerEnabled cannot be enabled simultaneously.

17382 HW PROTECTION (MSP/APS) NOT DEFINED FOR SETS

The state of the interface unit should not be changed to TE because equipment protection is not configured for the existing SETs that belong to this interface unit.

17383 FAULTY ALTERNATIVE IDENTIFICATION PARAMETERS GIVEN

The alternative parameters given are not allowed with some of the other identification parameters.

17384 FLEXIEDGE ABIS OVER IP/ETHERNET FEATURE IS NOT IN USE

The FlexiEDGE Abis over IP/Ethernet feature is not in use in BSC. Either the licence is missing, or the feature state is not ON.

17385 FLEXIEDGE ABIS OVER IP/ETHERNET CAPACITY IS EXCEEDED

The capacity of the FlexiEDGE Abis over IP/Ethernet feature has been exceeded. Increase the licence capacity or change the value of the BCF parameter Flexi EDGE Abis over IP/Ethernet usage to 0.

17386 FLEXIEDGE ADDITIONAL 2 E1/T1 FEATURE IS NOT IN USE

The FlexiEDGE Additional 2 E1/T1 feature is not in use in BSC. Either the licence is missing, or the feature state is not ON.

17387 FLEXIEDGE ADDITIONAL 2 E1/T1 FEATURE CAPACITY IS EXCEEDED

The capacity of the FlexiEDGE Additional 2 E1/T1 feature has been exceeded. Increase the licence capacity or decrease the value of the BCF parameter Flexi EDGE Additional 2 E1/T1 usage.

17388 FLEXIEDGE TRS ABIS GROOMING FEATURE IS NOT IN USE

The FlexiEDGE TRS Abis Grooming feature is not in use in BSC. Either the licence is missing, or the feature state is not ON.

17389 FLEXIEDGE TRS ABIS GROOMING FEATURE CAPACITY IS EXCEEDED

The capacity of the FlexiEDGE TRS Abis Grooming feature has been exceeded. Increase the licence capacity or change the value of the BCF parameter Flexi EDGE TRX Abis Grooming usage to 0.

Page 516: DX Error Messages

516 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17390 FLEXIEDGE TRS LOOP PROTECTION FEATURE IS NOT IN USE

The FlexiEDGE TRS Loop Protection feature is not in use in BSC. Either the licence is missing, or the feature state is not ON.

17391 FLEXIEDGE TRS LOOP PROTECTION FEATURE CAPACITY IS EXCEEDED

The capacity of the FlexiEDGE TRS Loop Protection feature has been exceeded. Increase the licence capacity or change the value of the BCF parameter Flexi EDGE TRS Loop Protection usage to 0.

17392 IPQM ID IS IN USE

The IPQM ID is in use.

17393 WRONG IPQM PARAMETER

The IPQM parameter is wrong.

17394 TOO MANY DESTINATION IP LISTS IN IPQM

Too many destination IP lists in IPQM.

17395 TOO MANY DESTINATION IP PREFIXES IN IPQM

Too many destination IP prefixes in IPQM.

17396 IF BB OR ANTENNA HOP IS USED THEN ALL TRXS MUST HAVE SAME VALUE FOR DTRX USAGE

All TRXs must use the same value for the Dual TRX Usage parameter if BB hopping or Antenna hopping is in use.

17397 IDD TRX AND DPTRX CANNOT BE USED AT THE SAME TIME IN BTS.

Double Power TRX (DPTRX) and Intelligent Downlink Diversity (IDD) TRX cannot be used at the same time in BTS. Modify the DTRX USAGE parameter.

17398 THE PREVIOUS TRX ID IS USED BY DOUBLE POWER OR IDD TRX

This even TRX ID is not allowed because the previous TRX ID is used by double-power TRX or IDD-enabled TRX. Use another TRX ID or disable Dual TRX usage (DTRX) in the previous TRX ID.

17399 RDIV MUST BE ON IF BTS HAS DPTRX OR IDD TRX

Set RX Diversity (RDIV) to ON if you want to use DPTRX or IDD TRX.

17400 DSP DID NOT INITIATE PREBOOT SEQUENCE

DSP did not send an Ethernet ready frame to OMU in time to indicate that the preboot loading phase can be started.

17401 DSP DMX MESSAGING ERROR AT STARTUP

After being restarted, the DSP has indicated that it is running the code loaded in its memory, but has failed to send the initial DMX startup message to OMU.

17402 IUB O&M MESSAGE RELAYING SERVICE NOT AVAILABLE

The Iub O&M message relaying service cannot be found in the system.

17403 NTOPOH RECEIVED MISMATCHED OPERATIONTYPE AND OBJECT

Page 517: DX Error Messages

DN987378Issue 24-0

517

General Error Messages of System DX error messages

Id:0900d8058077e097

The content of operationtype and object must be specified and their combination must be correct.

17404 NTOPOH DOES NOT RECOGNISE THE OPERATION TYPE MEN-TIONED IN DATA TYPE OF IUB O&M MESSAGE

Only Iub O&M message type required by BOIMED can be handled in NTOPOH. NTOPOH does not collect parameter values for other types.

17405 DSP SUPERVISION FAILURE

DSP has not acknowledged a supervision message that was sent to it.

17406 IU HAS ALREADY BEEN CREATED

The IU has already been created.

17407 ALL IU IDS ARE OCCUPIED

All Iu IDs are already occupied.

17408 IU ID IS IN USE

The IU ID is in use.

17409 WRONG IU PARAMETER

The IU parameter is wrong.

17410 CANNOT FIND IUR

Cannot find IUR.

17411 AN IUR HAD BEEN CREATED

An IUR had been created.

17412 ALL IUR IDS ARE OCCUPIED

All IUR IDs are occupied.

17413 IUR ID IS IN USE

The IUR ID is in use.

17414 IUR PARAMETER IS WRONG

The IUR parameter is wrong.

17415 IU STILL USED BY SOME WCEL

IU cannot be deleted because a WCEL is still using it.

17416 THE NUMBER OF IU OBJECTS EXCEEDS THE LIMIT

The number of IU objects must not exceed the maximum number in RNC.

17417 THE NUMBER OF IUR OBJECTS EXCEEDS THE LIMIT

The maximum number of IUR objects must not exceed the maximum number in RNC.

17418 NTOPOH RECEIVED INVALID OBJECT ID WITH ASCII FORMAT IN TOPOLOGY OPERATION

NTOPOH has received an invalid object ID in ASCII format that cannot be converted to hexadecimal format.

17419 GLOBAL CN ID OF IU CANNOT BE MODIFIED

The global CN ID of IU cannot be modified.

17420 DATABASE UNIQUE CONSTRAINT VIOLATION

Page 518: DX Error Messages

518 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

An attempt has been made to insert an object into the database that was defined as unique, but according to the key data of the object to be inserted, it is already in the database.

17421 AYSNMP CANNOT FIND XML ROW ID

AYSNMP cannot find the XML row ID.

17422 DIAGNOSIS IS NOT READY

The diagnosis is not ready.

17423 CALIBRATION IS NOT READY

Calibration is not ready.

17424 UNKNOWN MASK

Unknown mask.

17425 INVALID MASK

Invalid mask.

17426 SUPERVISION IS NOT READY

Supervision is not ready.

17427 MASTER IS UNABLE TO FORWARD MESSAGE TO HAND

The master is unable to forward the message to the hand.

17428 BINARY TO DECIMAL CONVERSION FAILED

Binary to decimal conversion failed.

17429 ASCII TO INTEGER CONVERSION FAILED

ASCII to integer conversion failed.

17430 AYSNMP IS UNABLE TO GET VALUE PART

AYSNMP cannot find the value part.

17431 HW IS NOT AVAILABLE

The hardware is not available.

17432 IU ID EXCEEDS THE RANGE

The IU ID has exceeded the acceptable range.

17433 IUR ID EXCEEDS RANGE

The IUR ID has exceeded the acceptable range.

17434 STATE CHANGE IS NOT POSSIBLE WHEN THE ROLE IS SERVER

When the role is server, it is not possible to send ASPSM or ASPTM messages to the peer network element in order to trigger a necessary state change.

17435 HSUPA 2.0 MBPS LICENCE STATE NOT ON

The state of the HSUPA 2.0 Mbps licence is not ON.

17436 GIVEN UNITS DO NOT SUPPORT CPLD FUNCTIONALITY

The given units do not support CPLD functionality.

17437 CPLD VERSION CAN BE CHECKED ONLY ON TOP PARENT UNIT

CPLD version information can be checked only on the top parent unit.

17438 DSP RESET FAILURE

Page 519: DX Error Messages

DN987378Issue 24-0

519

General Error Messages of System DX error messages

Id:0900d8058077e097

A failure occurred while setting DSP to, or releasing DSP from, reset state.

17439 INCORRECT CLGU STATE PREVENTS DESIRED UNIT STATE CHANGE

The state change is prevented because the depending CLGU is in an incorrect functional state. Correct the state of the CLGU before pro-ceeding.

17440 INCORRECT FUNCTIONAL STATE OF SWU PREVENTS DESIRED UNIT STATE CHANGE

The dependent SWU is in an incorrect functional state. The state of the SWU must be corrected before the desired state change can be per-formed.

17441 CANNOT FIND IPQM

The specified IPQM cannot be found.

17442 TOO MANY IPQM OBJECTS

Too many IPQM objects.

17443 IP BASED IUCS LICENSE NOT ACTIVE

The IP based IUCS license is not active.

17444 IP BASED IUPS LICENSE NOT ACTIVE

The IP Based IUPS licence is not active.

17445 NOT ENOUGH FLASH MEMORY IN SWITCH

The operation cannot be performed because the flash memory of the switch is full.

17446 REQUESTED SW VERSION ALREADY ACTIVE ON SWITCH

The requested software version is already active on the switch.

17447 INCORRECT RAML VERSION IN XML PLAN

The RAML version is the value of the attribute "version" in the element "raml".

17448 CMDATA ELEMENT NOT FOUND IN XML PLAN FILE

cmData is a mandatory element in the XML PLAN file.

17449 UNKNOWN RNW OBJECT NAME IN XML PLAN FILE

Unknown or incorrect object name in the XML PLAN file.

17450 THE PARAMETER NAME IN XML PLAN FILE IS NOT FOUND IN SCHEMA FILE

The parameter name in the XML PLAN file is not available.

17451 RNW OBJECT OPERATION IS NOT CORRECT IN XML PLAN FILE

The object operation is not available.

17452 IP BASED IU-CS AND IU-PS LICENCES ARE NOT BOTH IN STATE ON

The IP based IU-CS and IU-PS licences are not both in state ON.

17453 SUBNET_ID CANNOT BE DEFINED WITHOUT IP ADDRESSES

Subnet_id cannot be defined if no IP addresses are given.

Page 520: DX Error Messages

520 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17454 EVENT FORWARDING AND LOGGING SERVICE PROVIDED IN EEFPRB SERVICE NOT AVAILABLE

The event forwarding and logging service (eef_ext_event_as) cannot be found in the system.

17455 NO ACK OR NOT ALL ACKS RECEIVED FROM PROCESS IUETOR IN TIME

RAKTOR did not receive all ACKs, or received no ACKs at all, from IUETOR in time.

17456 NO RESPONSE FROM EEFPRB

The EEFPRB program block does not reply to the message sent.

17457 A SERIES HWILIB ROUTINE

An A series routine of HWILIB cannot be used in B series.

17458 PRXTARGET LESS THAN PRXTARGETPSMAX

The value of PrxTarget must be greater than or equal to that of PrxTar-getPSMax.

17459 NBAP COMMUNICATION MODE CANNOT BE MODIFIED

The NBAP communication mode cannot be modified.

17460 MISMATCH BETWEEN NBAP COMMUNICATION MODE AND NE-TYPE OF NODEB

The value of NBAP communication mode and ne-type do not match.

17461 INVALID COUNT OF SCCPCHS FOR NBAP COMMUNICATION MODE NB/RS

With NBAP communication mode NB/RS, the number of SCCPCHs should be less than 3.

17462 STARTING DSP MEMORY TEST

The DSP notifies the host computer that it is starting memory testing.

17463 DSP MEMORY TEST IS IN PROGRESS

This is a periodical phase notification from DSP to the host computer, indicating that the memory test is still in progress.

17464 GIVEN MAX VPI VALUE TOO HIGH FOR CURRENT SDH/SONET CONFIGURATION

The max VPI value given is too high for the current SDH/SONET con-figuration.

17465 DSP START-UP WAS ABORTED

The restart of DSP was aborted by a command from the user or the recovery system.

17466 PARSING OF TARGET BD XML FILE FAILED

The targetBD XML file could not be parsed successfully.

17467 UPDATING OF SW UPGRADE LOG FAILED

The SW upgrade log could not be updated successfully.

17468 FTP TRANSFER FAILED

The SW download failed because the FTP transfer failed.

Page 521: DX Error Messages

DN987378Issue 24-0

521

General Error Messages of System DX error messages

Id:0900d8058077e097

17469 OPENING OF FTP CONNECTION FAILED

The SW download failed because the FTP connection could not be opened.

17470 OTHER SW DOWNLOAD AND ACTIVATION IN PROGRESS

The SW download cannot be started because another operation is in progress.

17471 VIDEO ANNOUNCEMENTS ARE NOT SUPPORTED, NOT ENOUGH MEMORY FOR VMT FILES IN VANU UNIT(S)

Video announcements are not supported. There is not enough memory for the multimedia announcement sample files in the VANU unit(s).

17472 UNKNOWN RELEASE TYPE IN TARGETBD XML FILE

An error occurred while parsing the content of the targetBD XML file. The file contains an unknown release type.

17473 PREPARATION OF BASE OF NEW SW BUILD FAILED

An error occurred while the base of the new SW build was being built.

17474 UNZIPPING OF SW BUILD ARCHIVE FILE HAS FAILED

The SW build archive file could not be unzipped successfully.

17475 COMMAND SCRIPT EXECUTION FAILED

The execution of the command script has failed.

17476 SW BUILD VERIFICATION FAILED

The verification of the SW build has failed.

17477 SW BUILD ACTIVATION FAILED

The software build could not be activated successfully.

17478 NUMBER OF WRAB OBJECTS EXCEEDS THE LIMIT

The number of WRAB objects must not exceed the maximum in RNC.

17479 WRAB WITH EXISTING CELL ASSOCIATION(S) CANNOT BE DELETED

A WRAB object cannot be deleted if any cell or cells have associations with it. In order to be able to delete the WRAB, remove all associations of cells. After that, the WRAB object can be deleted.

17480 CD INSTALLATION FAILED

The change delivery installation was not completed successfully.

17481 PURGE FAILED WHEN INSTALLING SW BUILD

The purge of the SW build directories was not successful.

17482 PTXTARGET LESS THAN PTXTARGETPSMAX

PtxTarget must be greater than or equal to PtxTargetPSMax.

17483 CREATION OF NEW IAPRPB HAND PROCESS HAS FAILED

An attempt to create a new Iupc interface (PCAP protocol) Application Part Program Block (IAPPRB) hand process has failed. The maximum count of hand processes may be exceeded, or there are some other general problems in system services.

17484 SIGNATURE PATH IS NOT TRUSTED

Page 522: DX Error Messages

522 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The certificate cannot be validated because the signature cannot be verified.

17485 CERTIFICATE IS EXPIRED

The certificate is not valid at present. This may be because the certifi-cate is old or because its validity period is in the future.

17486 TEST LICENCE NOT ACCEPTED

This network element is in production use and test licences are not accepted.

17487 TEST LICENCE COOKIE IS EXPIRED

The cookie used in test licence validation is expired and cannot be used.

17488 DSP CORE DUMP FILE INCOMPLETE

The DSP core dump file could not be completed due to missing packets.

17489 CONVERT OF OBJECT CONTENTS TO XML FILE FAILS.

Pabros convert of object contents to xml file fails.

17490 PDCP_LID DATA NOT FOUND IN TRANSPARENT PARAMETERS

The returned transparent parameters do not contain any pdcp_lid infor-mation. The relevant program block should be found in the fault_origin field in error_data.

17491 MISSING RNW PLAN FEEDBACK MESSAGE CONVERT REQUEST.

PABROS does not receive feedback message convert request.

17492 CONVERT OF RNW PLAN FEEDBACK MESSAGE TO XML FILE FAILS.

PABROS convert of feedback message to xml file fails.

17493 TFO NEGOTIATION FAILED

The remote TFO peer is not replying to TFO negotiation attempts.

17494 CANNOT ESTABLISH TFO DUE TO CODEC INCOMPATIBILITY

It is not possible to establish TFO because of incompatible codec types or configurations.

17495 CODEC NOT SUPPORTED

This codec is not supported.

17496 NO TRANSCODER IN TERMINATION

No transcoder in termination.

17497 WRONG WRAB PARAMETER

The WRAB parameter is wrong.

17498 WRAB NOT FOUND

The WRAB object could not be found in the Radio Network Database.

17499 WRAB ALREADY CREATED

The WRAB object has already been created in the Radio Network Data-base.

17500 WRAB COLLECTION FULL

Page 523: DX Error Messages

DN987378Issue 24-0

523

General Error Messages of System DX error messages

Id:0900d8058077e097

There is no room for a new WRAB in the Radio Network Database.

17501 UNKNOWN FEEDBACK MESSAGE TYPE

Pabros has received a request to convert an unknown feedback message. The only valid types are download and activate.

17502 MODIFICATION OF WRAB IS REJECTED DUE TO ITS ASSOCIA-TION WITH AN UNLOCKED WCEL

Modification of WRAB is not allowded if any unlocked cell has an asso-ciation with it.

17503 EACH CELL SHOULD HAVE AN ASSOCIATION WITH A WRAB OBJECT

Each cell should have an association with a WRAB object.

17504 RF HOP CANNOT BE USED IN A PGSM-EGSM BTS WITH PGSM BCCH WITHOUT CORRECT LICENCE

If the state of the Single MA for EGSM and PGSM or GPRS/EDGE support for PGSM-EGSM BTS licence is not ON, RF hopping cannot be used in a BTS that has PGSM900 and EGSM900 frequencies defined and BCCH on PGSM900.

17505 DSP CORE DUMPING IN PROGRESS

DSP could not be reset or restarted because core dumping (storing the black box to disk) was still in progress.

17506 DSP INITIATED CORE DUMP UNEXPECTEDLY

DSP initiated the core dumping protocol via Ethernet without any prior fatal error notification. This may indicate that DMX messaging was not functional at the time when the fault was identified. Additional status information may be available in other status fields.

17507 IP BASED IUR LICENCE IS NOT ON

The IP based IUR licence is not on.

17508 DEFINED ROUTEID DOES NOT EXIST IN PLATFORM

The defined route ID does not exist in the platform.

17509 USER PLANE IPSEC CERTIFICATE KEY INSTALLATION TO DSP FAILED

The user plane IPSec certificate key installation in DSP failed.

17510 USER PLANE IPSEC POLICY INSTALLATION FAILED

The user plane IPSec policy installation failed in DSP.

17511 EXECUTION OF THE PING COMMAND FAILED

Execution of the ping command has failed.

17512 THE QOS FOR IP TRANSPORT LICENCE IS NOT ON

The QOS for IP transport licence is not on.

17513 UBRPLUS LICENCE FOR CONTROL PLANE IS NOT ON

The state of the UBRPLUS licence for the control plane is not ON.

17514 DSP FATAL ERROR INTERRUPTED BOOT SEQUENCE

Page 524: DX Error Messages

524 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

A DSP fatal error indication was received during the DSP startup sequence.

17515 NSE WITHOUT DYNAMIC CONFIGURATION

NSE without dynamic configuration.

17516 BCF SW DOES NOT SUPPORT LONG REACH TSL FEATURE

The BCF SW version does not support the Long Reach TSL (FlexiEdge BTS) feature.

17517 ILLEGAL LRTCH CONFIGURATION

The LRTCH configuration is illegal. LRTCHs must be configured to two successive TSLs of BCCH TRX (excluding TSLs 0 and 1). Any other combination is not allowed.

17518 TEST CANNOT BE PERFORMED IF TX RTSL IS SECOND LRTCH

The TRX test cannot be performed if the test channel reserved as TX channel is second LRTCH.

17519 TEST CANNOT BE EXECUTED IF RX RTSL IS SECOND LRTCH

The TRX test cannot be performed if the test channel reserved as RX channel is second LRTCH.

17520 SNTP CLIENT IS DISABLED. ALL CLIENT CONFIGURATION CHANGES AND QUERIES ARE FORBIDDEN

The SNTP client is disabled. This means that the feature is running in server-only mode. Since the functionality is disabled, configuration changes and queries of the SNTP client are not permitted.

17521 LONG REACH TSL FEATURE IS NOT IN USE IN THE BSC

The Long Reach TSL (FlexiEDGE BTS) feature is not enabled in the BSC. The licence state is not ON.

17522 LRTCH NOT IN EXTENDED OR SUPER EXTENDED CELL

LRTCH IS NOT ALLOWED TO BE CONFIGURED IN CELL THAT HAS NO EXTENDED OR SUPER EXTENDED CELL ENABLED.

17523 INVALID BCF SITE TYPE FOR LRTCH

It is not allowed to configure LRTCH to a BTS type other than Flexi EDGE BTS.

17524 ADJG-AdjgSIB SHOULD NOT BE SET AS 0 (NO) WHEN AMR CALL INTERSYSTEM HANDOVER IS ON

When AMR call intersystem handover is ON, AdjgSIB should not be set as 0 (no).

17525 OBJECT DISTNAME IS NOT VALID

The object distName is not valid.

17526 NO ANSWER FROM BOIMED

No reply from BOIMED.

17527 AUTOMATIC RETURN TO SPARE SW BUILD HAS BEEN EXECUTED

The system has automatically returned to the spare SW build.

Page 525: DX Error Messages

DN987378Issue 24-0

525

General Error Messages of System DX error messages

Id:0900d8058077e097

17528 IP ADDRESS EXISTS IN SAME SUBNET ON ANOTHER INTERFACE

The IP address is already configured in the same subnet on another interface of the unit.

17529 VLAN ID ALREADY SET ON PHYSICAL INTERFACE

The VLAN ID is already set on a Physical Interface.

17530 SAME VLAN PHYSICAL INTERFACES FOR REDUNDANT IP

Same VLAN physical interfaces for a Redundant IP address.

17531 CHANGE DELIVERY INSTALLATION ORDER IS INCORRECT

Change delivery installation order is incorrect

17532 GCD LEVEL IS LOWER THAN IN PREVIOUS CD

GCD level is lower than in previous CD.

17533 GCD LEVEL IS SAME THAN IN PREVIOUS CD

GCD level is the same as in the previous CD.

17534 GCD LEVEL IS TOO HIGH COMPARED TO PREVIOUS CD

GCD level is too high in comparison to the previous CD.

17535 GCD LEVEL IS HIGHER THAN IN PREVIOUS CD

GCD level is higher than in previous CD.

17536 GCD LEVEL IS UNKNOWN

GCD level is unknown.

17537 DSP FATAL ERROR DETECTED

DSP has detected a fatal error. The unit needs to be restarted to recover normal functionality.

17538 ENERGY SAVING MODE FOR BCCH TRX FEATURE IS NOT IN USE IN BSC

Energy Saving Mode for BCCH TRX feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

17539 SYSTEM TIME IS CHANGED, SO ACTOR HAS TO RESTART...

The change of system time leads to the restart of actor.

17540 TOO MANY DIFFERENT PLMNS

Theri is no room for a new PLMN under RNC.

17541 PLMN FOR RAI AND RNC MUST BE SAME

If MOCN feature is not used, the PLMN of RAI must be the same as the PLMN of the RNC receiving it.

17542 CONFLICT BETWEEN 2G AND 3G RAI

CONFLICT BETWEEN 2G AND 3G RAIS

17543 PAPU BELONGS TO PAPU GROUP

GIVEN PAPU BELONGS TO PAPU GROUP. IN SOME CASES EITHER THE PAPU OR PAPU GROUP SHALL BE GIVEN.

17544 LAST RAI ATTACHED TO RNC CANNOT BE DELETED

Last RAI attached to RNC cannot be deleted

Page 526: DX Error Messages

526 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17545 DTRX POWER DOWN THRESHOLD IS NOT HIGHER THAN DTRX POWER UP THRESHOLD

DTRX Power Down Threshold is not higher than DTRX Power Up Threshold.

17546 FLEXI EDGE DUAL TRX AUTOMATIC POWER DOWN FEATURE IS NOT IN USE IN BSC

Flexi EDGE Dual TRX automatic power down feature is not in use in BSC.

17547 LOAD AWARE INTER-BSC HO ADMISSION FEATURE IS NOT IN USE IN BSC

Load Aware Inter-BSC HO Admission is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

17548 LOAD AWARE ISHO ADMISSION FEATURE IS NOT IN USE IN BSC

Load Aware ISHO Admission feature is not enabled in BSC. Either feature licence is not valid or feature status is in disabled state.

17549 MAXIMUM NUMBER OF HSDPA CONGESTION CONTROL ENABLED WBTS EXCEEDED

The maximum number of HSDPA congestion control enabled WBTS exceeded

17550 THE SPECIFIED ADDITIONAL INTRA-FREQUENCY ADJACENT CELL HAS ALREADY BEEN CREATED.

The specified additional intra-frequency adjacent cell has already been created.

17551 THE SPECIFIED ADDITIONAL INTRA-FREQUENCY ADJACENT CELL UNDER WCDMA CELL DOES NOT EXIST.

The specified additional intra-frequency adjacent cell under WCDMA cell does not exist.

17552 MAXIMUM NUMBER OF ADDITIONAL INTRA-FREQUENCY ADJACENT CELLS EXCEEDED UNDER WCDMA CELL.

Maximum number of additional intra-frequency adjacent cells exceeded under WCDMA cell.

17553 NO PDH STATISTICS OR PARAMETERS WITH THIS UNIT

PDH statistics counters or PDH supervision related parameters are not used with this unit.

17554 ROBUST EDGE RETRANSMISSION FEATURE IS NOT IN USE IN BSC

Robust EDGE Retransmission feature is not in use in BSC.

17555 USING OF GPRS IS NOT ALLOWED IN THE RF HOP TRX IN THE PGSM-EGSM BTS WITH PGSM BCCH TRX

Using of GPRS is not allowed in the RF hopping PGSM900-EGSM900 BTS, if the frequency of the BCCH TRX is PGSM900 type.

17556 TRX AND DAP TIMESLOTS NOT MAPPED TO SAME PW

Abis TCH and TRXSIG timeslots are mapped into different Pseudowire than the DAP timeslots.

Page 527: DX Error Messages

DN987378Issue 24-0

527

General Error Messages of System DX error messages

Id:0900d8058077e097

17557 ILLEGAL PW TIMESLOT MAPPING FOR DAP

All timeslots of the DAP are not mapped into the same pseudowire or DAP timeslot(s) is/are missing from the pseudowire timeslot mapping.

17558 ILLEGAL PW TIMESLOT MAPPING FOR TRX

TRX traffic channel and TRXSIG timeslots are either allocated into dif-ferent pseudowires or timeslot(s) is/are missing from the pseudowire timeslot mapping.

17559 PCU CONFIGURATION IS IN PROGRESS

Operation cannot be completed because PCU is under configuration.

17560 DYNAMIC ABIS POOL OPERATION IS ONGOING

Operation cannot be completed because Dynamic Abis Pool operation is ongoing in PCU.

17561 PCU IS RESTARTING

Operation cannot be completed because PCU is restarting.

17562 PCU OBJECT DOES NOT FOUND

No records were found with given PCU information from PCU object col-lection of radio network database.

17563 HSDPA 64 USERS PER CELL LICENSE STATE CONFIG/OFF, NOT ON

HSDPA64UsersEnabled cannot be activated because the state of the HSDPA 64 Users per Cell licence is CONFIG/OFF, not ON.

17564 PASSWORD MUST BE CHANGED AFTER LOGIN

Password must be changed immediately after login (Feature 31557) (not as previously when login succeeded, but only ZIAG command was in use).

17565 AMR-WB WITH TFO FEATURE IS NOT IN USE IN THE BSC

The licence of the AMR-WB application software must exists in BSC and the state of the licence must be ON before activation of the feature.

17566 MAX AMR-WB TRX LIMIT OF AMR-WB LICENCE EXCEEDED

Capacity limit for AMR-WB licence is exceeded in BSC because there are too many AMR-WB TRXs defined into use in BSC.

17567 BCF SW DOES NOT SUPPORT AMR-WB FEATURE

BCF SW version does not support AMR-WB feature.

17568 FAST UE THRESHOLD NOT GREATER THAN FAST UE CANCEL

The value of FAST UE THRESHOLD must be greater than the value of FAST UE CANCEL.

17569 SAS CENTRIC MODE CAN ONLY BE SELECTED IF LCSINTERFA-CEOPTION HAS VALUE IUPC

SAS Centirc mode can only be selected if LCSInterfaceOption has value Iupc.

17570 CGR IS USED FOR OTHER CIC RANGE

CGR is assigned to different additional SPC (CIC range).

Page 528: DX Error Messages

528 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17571 ADJD NOT FOUND

The ADJD object cannot be found in radio network database.

17572 ADJD COLLECTION FULL

There is no room for a new ADJD object in radio network database.

17573 MAXIMUM OF ADJDS FOR WCEL

The maximum of ADJD object relations for the Cell (WCEL) object is reached.

17574 ADJD ALREADY CREATED UNDER WCEL

An Intra Frequency Adjacency (ADJD) object with the given id entity is already created under given WCEL id in radio network database.

17575 INVALID USERPLANE WHEN HSUPA ENABLED

Userplane should be HSUPA or HSPA type on the connected COCO when the unlock of the HSUPA enabled WCEL.

17576 MAX S-TRX CAPACITY LIMIT OF 105KM EXTENDED CELL LICENCE EXCEEDED

Max S-TRX capacity limit of 105KM extended cell licence exceeded.

17577 BTS SOFTWARE DOES NOT SUPPORT 105KM EXTENDED CELL FEATURE

BTS software does not support 105KM extended cell feature.

17578 105KM EXTENDED CELL FEATURE NOT IN USE IN BSC

105KM extended cell feature not in use in BSC.

17579 THERE IS NO E-RACH S-TRX UNDER SUPER EXTENDED AREA

There is no E-RACH S-TRX under super extended area.

17580 THERE IS NO UNLOCKED E-RACH S-TRX UNDER SUPER EXTENDED AREA

There is no unlocked E-RACH S-TRX under super extended area.

17581 ZERO IS NOT ALLOWED RANGE FOR SUPER EXTENDED AREA OF THE CELL

Zero is not in the allowed range for super extended area of the cell.

17582 MIXED 2UD AND 4UD CONFIGURATION NOT ALLOWED IN EXTENDED OR SUPER EXTENDED CELL

Mixed 2UD and 4UD configuration is not allowed in extended or super extended cell.

17583 105KM EXTENDED CELL FOR GPRS/EDGE FEATURE IS NOT IN USE IN THE BSC

The licence of the 105KM extended cell for GPRS/EDGE application software must exist in BSC and the state of the licence must be ON before EGTCH S-TRXS is defined into use in BSC.

17584 MAX EGTCH S-TRX CAPACITY LIMIT OF 105KM EXTENDED CELL FOR GPRS/EDGE LICENCE EXCEEDED

Page 529: DX Error Messages

DN987378Issue 24-0

529

General Error Messages of System DX error messages

Id:0900d8058077e097

Capacity limit for 105KM extended cell for GPRS/EDGE licence is exceeded in BSC because there are too many EGTCH S-TRXS defined into use in BSC.

17585 UNIT STATE INFORMATION IS NOT AVAILABLE

Unit state information is not available.

17586 CONFIGURATION DOES NOT EXIST

The configuration does not exist.

17587 RNC IS CONNECTED TO IPOA LINK

RNC connection to IP over ATM link exists in SGSN.

17588 PLMN ID IN GLOBALCNID OF IU ITEM NOT FOUND IN IU OPERATOR LIST

PLMN ID defined in GlobalCNID of IU item cannot be found in IU operator list.

17589 IU OPERATOR CAN NOT BE DELETED OR MODIFIED BECAUSE ITS PLMNID IS USED BY IU ITEM

IU operator can ot be deleted or modified because its PLMNID is used by IU item.

17590 PLMNID IN IU OPERATOR LIST SHOULD BE UNIQUE

PLMNID defined in IU operator list should be unique.

17591 ADJD CANNOT BE CREATED OR MODIFIED IF FEATURE STATE OF DETECT SET REPORTING BASED SHO OFF

Additional intra-frequency adjacent cell cannot be created or modified while the feature state of Detected Set Reporting Based SHO is OFF.

17592 ADJD AND SOURCE CELL MUST HAVE DIFFERENT PRIMARY SCRAMBLING CODE

Additional intra-frequency adjacent cell and source cell must have dif-ferent Primary Scrambling Code.

17593 PRIMARY SCRAMBLING CODE MUST BE UNIQUE WITHIN ADJD OF THE SAME SOURCE CELL

Primary Scrambling Code must be unique within additional intra-fre-quency adjacent cell of the same source cell.

17594 PRIMARY SCRAMBLING CODE OF AN ADJS AND AN ADJD OF THE SAME SOURCE WCEL MUST BE DIFFERENT

Primary Scrambling Code of a basic and an additional intra-frequency adjacent cell of the same source cell must be different.

17595 THE SAME TARGET CELL IS POINTED BY AN ADJD OF THE SAME SOURCE CELL

The same target cell is pointed by an additional intra-frequency adjacent cell of the same source cell.

17596 THE SAME TARGET CELL IS POINTED BY AN ADJS OF THE SAME SOURCE CELL

The same target cell is pointed by an intra-frequency adjacent cell of the same source cell.

Page 530: DX Error Messages

530 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17597 SOURCE AND TARGET CELLS MUST HAVE SAME FREQUENCY IN ADJD

The source cell and the target cell in an additional intra-frequency adjacent cell relation must have same frequency.

17598 HSDPA HOPS ID MUST BE DEFINED FOR OUTGOING ADJD OF HSDPA ENABLED CELL

HSDPA HOPS identifier must be defined for outgoing additional intra-frequency adjacent cell of HSDPA enabled cell.

17599 RT HSDPA HOPS MUST BE DEFINED FOR ADJD OF HSDPA ENABLED CELL IF RNC SUPPORTS AMRWITHHSDSCH

HSDPA HOPS identifier for AMR multi-service must be defined for outgoing additional intra-frequency adjacent cell of HSDPA enabled cell while RNC supports AMRWithHSDSCH.

17600 SOURCE AND TARGET CELLS MUST HAVE DIFFERENT PRIMARY SCRAMBLING CODE IN ADJD

The source cell and the target cell in an additional intra-frequency adjacent cell relation must have different Primary Scrambling Code.

17601 AAL2UP UNDER SAME VCC BUNDLE SHOULD BE UNDER SAME ATM INTERFACE.

In COCO, AAL2UPs with different ATM interface are not allowed to be put in the same VCC bundle.

17602 UNSUPPORTED PLUG-IN UNIT TYPE OR VARIANT.

Plug-in unit type or plug-in unit type variant is not supported.

17603 DEVICE DRIVER IS NOT STARTED.

Device driver is not started yet.

17604 FLEXIBLE IU AND MULTIPLE CN CANNOT BE BOTH ON

Multiple CN is not supported simultaneously with Flexible Iu.

17605 RADIO LINK TIMEOUT PARAMETER FOR AMR HR FEATURE IS NOT IN USE IN BSC

Radio link timeout parameter for AMR HR feature is not enabled in the BSC. Either licence is not valid or feature status is in disabled state.

17606 LOAD BASED AMR PACKING FEATURE IS NOT IN USE IN THE BSC

Load based AMR packing feature is not enabled in the BSC. Either feature licence is not valid or feature status is in the disabled state.

17607 TQM NOT FOUND

The TQM object cannot be found in radio network database.

17608 TQM COLLECTION FULL

There is no room for a new TQM object in radio network database.

17609 TQM WITH SAME ID ALREADY CREATED

An TQM object is being created and TQM with same identifier already exists.

17610 IPNB NOT FOUND

Page 531: DX Error Messages

DN987378Issue 24-0

531

General Error Messages of System DX error messages

Id:0900d8058077e097

The IPNB object cannot be found in Radio Network Database.

17611 IPNB COLLECTION FULL

There is no room for a new IPNB object in Radio Network Database.

17612 IPNB ALREADY CREATED.

An IPNB object with the given identity is already created in Radio Network Database.

17613 COMMAND IS NOT POSSIBLE BECAUSE STATUS EXISTS IN SOME UNIT

Command is not possible because the status exists already in some unit.

17614 MULTIOPERATOR BSS FEATURE IS NOT IN USE IN BSC

The Multioperator BSS feature is not enabled in BSC (Base Station Controller). Either the feature state is not valid or the feature is in disabled state

17615 IPNB AND WBTS ALREADY RELATED

The relation between the IPNB object and WBTS object already exists.

17616 NO RELATION BETWEEN IPNB AND WBTS

No relation between the IPNB object and WBTS object.

17617 IPST OBJECT NOT FOUND

The IPST object cannot be found in Radio Network Database.

17618 UNKNOWN PARAMETER FOR IPNB IN RNW PLAN

XML file processing program block (PABROS,RNC OMU) has detected an unknown (or incorrectly placed) IPNB object parameter in the RNW plan file.

17619 IPNB MANAGEMENT BUSY (RNC OMU)

RNW Plan Manager program block has detected that RNW Connection Configuration program block (VEXELI, RNC OMU) is busy (ongoing IPNB operation) and therefore RNW Plan operation cannot be contin-ued.

17620 THE NUMBER OF DUAL IUB ENABLED WBTS EXCEEDS THE DUAL IUB CAPACITY LIMIT

The number of Dual Iub enabled WBTS exceeds the capacity of license Dual Iub.

17621 THE NUMBER OF IP BASED IUB ENABLED WBTS EXCEEDS THE CAPACITY OF LICENSE IP BASED IUB.

The number of IP Based Iub enabled WBTS exceeds the capacity of license IP Based Iub.

17622 THE IP BASED ROUTE ID NOT UNIQUE UNDER WBTS OBJECT.

The IP Based route id is not unique under WBTS object.

17623 IUBTRANSPORTMEDIA IS NOT ATM, IPBASEDROUTEIDIUB MUST BE DEFINED.

When IubTransportMedia is not ATM, IP Subnet id must be defined.

Page 532: DX Error Messages

532 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

17624 IPNB OBJECT IS BEING USED BY SOME WBTS.

IPNB cannot be connected to the requested WBTS because it is already being used by some WBTS.

17625 DUPLICATE CCP IDS IN DNBAP LIST

Duplicate Communication Control Port IDs are found in DNBAP list.

17626 INVALID DNBAP SCTP PORT

Sum of DNBAP CCP ID and Minimum SCTP PORT is bigger than 65535.

17627 NO DEFINED CCP ID

No CCP ID in DNBAP list is defined.

17628 IPNB ID AND WBTS ID DO NOT MATCH

The IPNB ID and WBTS ID given in the service request are not related to each other in the system.

17629 MAXIMUM AMOUNT OF IPNB OBJECTS EXCEEDED

The IPNB object creation is not possible because the maximum amount of IPNB objects has already been created in the system.

17630 THE NUMBER OF HSDPA 14MBPS PER USER ENABLED WBTS EXCEEDS THE CAPACITY LIMIT

The number of HSDPA 14Mbps per user enabled wbts exceeds the capacity limit set by the licence.

17631 HSDPA 14MBPS PER USER CANNOT BE ENABLED WHEN THE PLUG-IN UNIT TYPE CDSP-DH IS NOT FOUND

The parameter of HSDPA 14Mbps per user can be enabled only when the hardware of CDSP-DH is working well.

17632 HSDPA 14MBPS PER USER CAN BE ENABLED ONLY IF HSDPA DYNAMIC RESOURCE ALLOCATION IS ENABLED

HSDPA 14Mbps per user can be enabled only when HSDPA dynamic resource allocation is enabled. HSDPA dynamic resource allocation cannot be disabled when HSDPS 14Mbps per user is enabled.

17633 THE NUMBER OF HSPA MULTI NRT RAB ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSPA multi nrt rab enabled bts exceeds the capacity limit set by license.

17634 HSPA MULTI NRT RAB CAN BE ENABLED ONLY WHEN HSDPA IS ENABLED

HSPA multi nrt rab can be enabled only when HSDPA is enabled.

17635 AMRUNDERTXTOTAL MUST BE SMALLER THAN AMRTARGETTX-TOTAL

AMRUnderTxTotal must be smaller than AMRTargetTxTotal.

17636 AMRTARGETTXTOTAL MUST BE SMALLER THAN AMROVERTX-TOTAL

AMRTargetTXtotal must be smaller than AMROverTxtotal.

17637 AMRUNDERTXNC MUST BE SMALLER THAN AMRTARGETTXNC

Page 533: DX Error Messages

DN987378Issue 24-0

533

General Error Messages of System DX error messages

Id:0900d8058077e097

AMRUnderTxNC must be smaller than AMRTargetTxNC.

17638 AMRTARGETTXNC MUST BE SMALLER THAN AMROVERTXNC

AMRTargetTxNC must be smaller than AMROverTxNC.

17639 AMRUNDERTXNONHSPA MUST BE SMALLER THAN AMRTAR-GETTXNONHSPA

AMRUnderTxNonHSPA must be smaller than AMRTargetTxNonHSPA.

17640 AMRTARGETTXNONHSPA MUST BE SMALLER THAN AMROVERTXNONHSPA

AMRTargetTxNonHSPA must be smaller than AMROverTxNonHSPA.

17641 AMRUNDERSC MUST BE SMALLER THAN AMRTARGETSC

AMRUnderSC must be smaller than AMRTargetSC.

17642 AMRTARGETSC MUST BE SMALLER THAN AMROVERSC

AMRTargetSC must be smaller than AMROverSC.

17643 AMRUNDERTRANSMISSION MUST BE SMALLER THAN AMRTAR-GETTRANSMISSION

AMRUnderTransmission must be smaller than AMRTargetTransmis-sion.

17644 AMRTARGETTRANSMISSION MUST BE SMALLER THAN AMROVERTRANSMISSION

AMRTargetTransmission must be smaller than AMROverTransmission.

17645 TOO MANY ITEMS IN LIST PARAMETER.

RNW Plan list parameter contains too many items.

17646 THE NUMBER OF QOS AWARE HSPA SCHEDULING ENABLED BTS EXCEEDS THE LICENSED CAPACITY

The number of QoS Aware HSPA Scheduling enabled BTS exceeds the licensed capacity.

17647 THE NUMBER OF HSPA WITH STREAMING QOS SUPPORT ENABLED BTS EXCEEDS THE LICENSED CAPACITY

The number of HSPA with Streaming QoS Support enabled BTS exceeds the licensed capacity.

17648 HSPA QOS FOR NRT, HSPA STREAMING, CS VOICE OR HSPA STREAMING CS VOICE CAN BE USED IF HSDPA DYN RES ALLOC USED

If parameter HSPA QoS Enabled indicates that HSPA QoS is used for NRTs, HSPA streaming, CS voice or HSPA streaming CS voice is in use, HSDPA Dynamic Resource Allocation must be enabled.

17649 NB/RSXXX BTS DOES NOT SUPPORT STREAMING QOS FOR HSPA FEATURE

NB/RSxxx BTS does not support Streaming QoS for HSPA feature.

17650 HSPA QOS FOR NRT, HSPA STREAMING, CS VOICE OR HSPA STREAMING CS VOICE CAN BE USED ONLY WHEN HSDPA IS ENABLED

Page 534: DX Error Messages

534 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

If parameter HSPA QoS Enabled indicates that HSPA QoS is used for NRTs, HSPA streaming, CS voice or HSPA streaming CS voice is in use, HSDPA must be enabled.

17651 THE STATE OF LICENCE FEATURE QOS AWARE HSPA SCHEDUL-ING IS NOT ON

The state of licence feature QoS Aware HSPA Scheduling is not ON.

17652 THE STATE OF LICENCE FEATURE HSPA WITH STREAMING QOS SUPPORT IS NOT ON

The state of licence feature HSPA with Streaming QoS Support is not ON.

17653 PRIORITIES FOR STREAMING RABS MUST BE BIGGER THAN PRIORITY FOR INTERACTIVE SIGNALING RABS

Priorities for streaming RABs must be bigger than priority for interactive signaling RABs.

17654 PRIORITY FOR INTERACTIVE SIGNALING RABS MUST BE BIGGER THAN PRIORITIES FOR OTHER NRT RABS

Priority for interactive signaling RABs must be bigger than priorities for other interactive and backgroud RABs.

17655 PRIORITY FOR INTERACTIVE SIGNALING RAB MUST BE BIGGER THAN RT OVER NRT PRIORITY THRESHOLDS

Priority for interactive signaling RABs must be bigger than RT over NRT priority thresholds if RT over NRT is used for that specific ARP category.

17656 INITIAL BR FOR HSDPA UL DCH FOR NRT WITH STREAMING CANNOT BE SAMLLER THAN MIN ALLOWED BR

Initial bitrate for HSDPA UL DCH for NRT with streaming must be bigger than or equal to minimum allowed bitrate for HSDPA UL DCH for NRT with streaming.

17657 HSDPAINITIALBRULSTRNRT CAN BE 16 KBPS ONLY IF HSDPA16KBPSRETURNCHANNEL IS ENABLED

Initial bitrate for HSDPA UL DCH for NRT with streaming can be 16 kbps only if HSDPA 16 kbps UL DCH return channel switch is turned on.

17658 HSDPAMINBRULSTRNRT CAN BE 16 KBPS ONLY IF HSDPA16KBPSRETURNCHANNEL IS ENABLED

Minimum allowed bitrate for HSDPA UL DCH for NRT with streaming can be 16 kbps only if HSDPA 16 kbps UL DCH return channel switch is turned on.

17659 PRIORITIES WITH NBR AT DL DIRECTION MUST START FROM PRIORITY OF INTERACTIVE SIGNALING RABS

Priorities with HSPA NBR at downlink direction must start from the priority used for interactive signaling RABs.

17660 PRIORITIES WITH NBR AT UL DIRECTION MUST START FROM PRIORITY OF INTERACTIVE SIGNALING RABS

Priorities with HSPA NBR at uplink direction must start from the priority used for interactive signaling RABs.

Page 535: DX Error Messages

DN987378Issue 24-0

535

General Error Messages of System DX error messages

Id:0900d8058077e097

17661 PRIORITIES WITH NBR AT DL DIRECTION MUST COVER FROM THE HIGHEST PRIORITIES USED FOR NRTS

The priorities set with NBR in downlink direction must cover from the highest priorities assigned for interactive and background traffic classes in parameter QoSPriorityMapping. If a priority is not used in QoSPriori-tyMapping, it cannot be set with NBR. For example, 12, 11, 8, 5, 0 are defaultly set as NRT priorities, you cannot set NBR only for NBRForPri8DL and NBRForPri12DL , but NBRForPri11DL must also be set.

17662 PRIORITIES WITH NBR AT UL DIRECTION MUST COVER FROM THE HIGHEST PRIORITIES USED FOR NRTS

The priorities set with NBR in uplink direction must cover from the highest priorities assigned for interactive and background traffic classes in parameter QoSPriorityMapping. If a priority is not used in QoSPriori-tyMapping, it cannot be set with NBR. For example, 12, 11, 8, 5, 0 are defaultly set as NRT priorities, you cannot set NBR only for NBRForPri8DL and NBRForPri12DL, but NBRForPri11DL must also be set.

17663 THE NUMBER OF HSUPA 3 USERS PER BTS ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSUPA 3 Users Per BTS enabled BTS exceeds the capacity limit.

17664 THE NUMBER OF HSUPA 12 USERS PER BTS ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSUPA 12 Users Per BTS enabled BTS exceeds the capacity limit.

17665 THE NUMBER OF HSUPA 24 USERS PER BTS ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSUPA 24 Users Per BTS enabled BTS exceeds the capacity limit.

17666 THE NUMBER OF HSUPA 60 USERS PER BTS ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSUPA 60 Users Per BTS enabled BTS exceeds the capacity limit.

17667 THE NUMBER OF HSDPA 64 USERS PER CELL ENABLED BTS EXCEEDS THE CAPACITY LIMIT

The number of HSDPA 64 Users Per Cell enabled BTS exceeds the capacity limit.

17668 HSDPA 64 USERS PER CELL LICENCE STATE NOT ON

The state of licence feature HSDPA 64 Users Per CELL is not ON.

17669 HSUPA 3 USERS PER BTS LICENCE STATE NOT ON

The state of licence HSUPA 3 Users Per BTS is not ON.

17670 HSUPA 12 USERS PER BTS LICENCE STATE NOT ON

The state of licence HSUPA 12 Users Per BTS is not ON.

17671 HSUPA 24 USERS PER BTS LICENCE STATE NOT ON.

Page 536: DX Error Messages

536 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The state of licence HSUPA 24 Users Per BTS is not ON.

17672 HSUPA 60 USERS PER BTS LICENCE STATE NOT ON

The state of licence HSUPA 60 Users Per BTS is not ON.

17673 HSDPA 64 USERS ENABLED CAN BE ENABLED ONLY WHEN HSDPA ENABLED IS ENABLED.

The value of parameter HSDPA 64 Users Enabled can be enabled only when the value of parameter HSDPA Enabled is enabled.

17674 IF HSUPA IS ENABLED, NUMBEREDCHRESERVEDSHO-BRANCHADDITIONS MUST BE LOWER THAN HSUPAXUSERSEN-ABLED

If HSUPA is enabled then the value of parameter Number of E-DCHs reserved for SHO branch additions must be lower than the value of parameter hsupa x users enabled.

17675 HSUPA ENABLED CANNOT BE ENABLED IF HSUPA X USERS ENABLED IS NOT ENABLED.

HSUPA Enabled cannot be enabled if HSUPA X Users Enabled value is not enabled and HSUPA X Users Enabled cannot be disabled when HSUPA Enabled value is enabled.

17676 HLR IS NOT IN CURRENT DXT

Home Location Register (subscriber or group) is not in the current DXT.

17677 IP BASED ROUTE HAS NO FREE BANDWIDTH.

There is no free bandwidth within the IP based route.

17678 IP BASED ROUTE DOES NOT EXIST.

The specified IP based route does not exist.

17679 IP BASED ROUTE ALREADY EXISTS.

The specified IP based route already exists.

17680 IP BASED ROUTE COMMITTED BANDWIDTH IS TOO LARGE.

The specified IP based route committed bandwidth is too large.

17681 IP BASED ROUTE COMMITTED SIGNAL BANDWIDTH IS TOO LARGE.

The specified IP based route committed signal bandwidth is too large.

24000 CIRCUIT GIVEN MORE THAN ONCE

The same circuit is given more than once.

24001 PCM NOT IDLE

The PCM circuit is not idle.

24200 CIRCUIT ALREADY FIXED TO ANOTHER CCSPCM

The PCM circuit is defined to another destination point.

24203 CIRCUIT NOT BLOCKED

The circuit is not blocked.

24204 CIRCUIT NOT BARRED

The circuit is not barred.

Page 537: DX Error Messages

DN987378Issue 24-0

537

General Error Messages of System DX error messages

Id:0900d8058077e097

24205 CIRCUIT NOT SEPARATED

The circuit is not separated.

24206 CIRCUIT NOT IN CIRCUIT GROUP

The circuit does not belong to the given circuit group.

24207 SIGNALLING NONEXISTENT

Signalling does not exist.

24839 TEST SEQUENCE TIME-OUT

The total time limit of measurement has expired. Try again after a while.

24854 SUBSCRIBER ONHOOK

The telephone is closed for some reason. The testing of loop dialling is started again after a while.

25089 PAYPHONE IN LINE BLOCKED STATE

At the moment of measurement the measured subscriber line has been in line blocking state, which is not necessarily a fault situation. The sub-scriber may be moved into the line blocking state when the receiver is lifted up for a period long enough, without detecting dialling. In this case the loop resistance of the line is the insulation resistance between a- and b-conductors in the measurement values.

25093 PAYPHONE IN BUSY STATE

The measured subscriber line is in BUSY state. Try again after a while.

25094 RINGING GROUP IN BUSY STATE

In the ringing group into which the subscriber line to be measured belongs, there is a call in progress. Try again after a while.

25096 TEST LINE OF SUBSCRIBER MODULE IN USE

In the subscriber module the test line already is reserved for performing another test. Try again after a while.

25097 SSP COMMUNICATION FAILURE

Communication with the subscriber module (SUB) to which the sub-scriber line to be measured is connected, does not succeed. Usually this is a temporary disturbance. Try again after a while.

25101 PAYPHONE CALLED DURING TEST

The subscriber line to be measured received a call during test. Try again after a while.

25102 RINGING GROUP CALL INTERRUPTION

The ringing group to which the subscriber line to be measured belongs, received a call during test. Try again after a while.

25106 INVALID POSITION NUMBER

The position number with which the subscriber line to be measured was identified, is incorrect.

25107 LINE NOT IN TEST

Page 538: DX Error Messages

538 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

The subscriber line that is required to be released from an external mea-surement device, is not in the test.

25141 PAYPHONE SUPERVISION CHANGE ALREADY ACTIVATED

The supervision change of a payphone already is activated. Try again after a while.

25173 CONTINUOUS SUPERVISION NOT STARTED

The continuous supervision is not started because the connection to the PMU is faulty. Check the ASS-channel conection and the PMU working state.

25184 CONFLICT WITH XMCONF FILE

A conflict with the XMCONF file has been detected. Load the XMCONF file from the disk and try again.

25189 MULTIPLE MEASUREMENT FAILURE

So many errors have been detected on the measured subscriber line that the measurement is not be completed. Repeat the measurement. If the result still is the same, locate the line fault by using other methods.

25344 IMPROPER LINE INTERFACE NUMBER

The interface number is invalid.

25345 SUBSCRIBER NOT IN TEST

The subscriber is not in test.

25346 UNEQUIPPED EXTENSION

The extension is unequipped.

25348 CM COMMUNICATION FAILURE

Communication failure with the central memory (CM).

25349 OMU COMMUNICATION FAILURE

Communication failure with the operation and maintenance unit (OMU).

25350 SMUC COMMUNICATION FAILURE

Communication failure with the subscriber stage maintenance unit con-troller (SMUC).

25351 LTEST COMMUNICATION FAILURE

Communication failure with the line test unit (LTEST).

25352 SBMTI COMMUNICATION FAILURE

Communication failure with the subscriber module test interface (SBMTI).

25353 SUB UNIT NOT IN WO-EX STATE

The SUB is not in state WO-EX.

25354 FAILURE IN LITI COMMUNICATION

Communication failure with the line test interface (LITI).

25355 TEST EQUIPMENT QUEUE IS FULL

The equipment queue is full.

25356 EXCESSIVE AC VOLTAGE

Page 539: DX Error Messages

DN987378Issue 24-0

539

General Error Messages of System DX error messages

Id:0900d8058077e097

Excessive alternating voltage.

25357 EXCESSIVE DC VOLTAGE

Excessive direct voltage.

25360 LITI UNIT FAULTY

The LITI plug-in unit is faulty.

25361 SBMTI UNIT FAULTY

The SBMTI plug-in unit is faulty.

25362 TEST EQUIPMENT QUEUE RESERVATION TIME-OUT

The time limit of test equipment queue reservation has expired.

25363 TEST EQUIPMENT QUEUE TIME-OUT

The time limit of test equipment queueing has expired.

25364 MEASUREMENT UNIT NOT IN WO-EX STATE

The measurement unit is not in state WO-EX.

25365 UNKNOWN MEASUREMENT UNIT

The measurement unit is unknown.

25366 UNKNOWN SUB UNIT

The subscriber module (SUB) is unknown.

25367 INTERNAL DATA ERROR

An internal data error has occurred.

25368 SPEECHWAY CONNECTION FAILURE

An error has occurred in the connection to the speechway.

25369 MEASUREMENT AMPLIFIER FAILURE ON LITI

There is a measurement amplifier failure on the LITI board.

25370 SUBSCRIBER FEED VOLTAGE FAILURE ON LITI

There is a subscriber feed voltage failure on the LITI board.

25371 CONSTANT CURRENT SOURCE FAILURE ON LITI

There is a constant current source failure on the LITI board.

25372 AD - DA FAILURE ON LITI

There is an AD-DA conversion failure on the LITI board.

25373 TONE SEND FAILURE ON LITI

There is a tone sending failure on the LITI board.

25374 RELAY CHAIN 1 FAILURE ON LITI

There is a failure of the relay chain 1 on the LITI board.

25375 RELAY CHAIN 2 FAILURE ON LITI

There is a failure of the relay chain 2 on the LITI board.

25376 RELAY CHAIN 3 FAILURE IN LITI

There is a failure of the relay chain 3 on the LITI board.

25377 FAULTY LINE INTERFACE

The line interface is faulty.

Page 540: DX Error Messages

540 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

25378 TEST NOT PERMITTED

The test is not permitted.

25379 INTERFACE UNIT NOT SUITABLE FOR TEST

The interface unit is not suitable to be tested.

25380 NOT NORMAL SUBSCRIBER LINE TYPE

The subscriber line type is not normal.

25381 LINE ALREADY CONNECTED TO EXTERNAL DEVICE

The line is already connected to an external measurement device.

25382 LINE NOT CONNECTED TO EXTERNAL DEVICE

The line is not connected to an external measurement device.

25383 TEST NOT POSSIBLE

The testing is not possible.

25400 ANNOUNCEMENT NONEXISTENT

The announcement does not exist.

28417 UNKNOWN MESSAGE IDENTIFICATION

Message identification is unknown.

28424 INCORRECT SUBSCRIBER NUMBER

The subscriber number is invalid.

28425 INCORRECT POSITION NUMBER

The position number is invalid.

28426 FILE SPACE LIMIT EXCEEDED

The file space limit is exceeded.

28448 SUBSCRIBER NUMBER VACANT

The subscriber number is vacant.

28449 SUBSCRIBER NUMBER RESERVED

The subscriber number is reserved.

28450 SUBSCRIBER NUMBER CHANGED

The subscriber number is changed.

28453 SUBSCRIBER NUMBER RESERVED FOR DPABX

The subscriber number is reserved for DPABX.

28466 NONEXISTENT MODULE

The module does not exist.

28467 NONEXISTENT STAGE

The stage does not exist.

28468 NONEXISTENT PLUG-IN UNIT

The plug-in unit does not exist.

28480 INCOMPATIBLE MODULE TYPE

The module type is incompatible.

28481 ISDN GLOBAL NUMBER WITHOUT MSN

Page 541: DX Error Messages

DN987378Issue 24-0

541

General Error Messages of System DX error messages

Id:0900d8058077e097

An ISDN global number without multiple subscriber number (MSN).

28482 MAXIMUM NUMBER OF MSN FOR SUBSCRIBER EXCEEDED

The maximum number of multiple subscriber numbers (MSN) for the subscriber is exceeded.

28483 TAC SET FOR SUBSCRIBER

The terminal access code (TAC) is set for the subscriber.

28484 ISDN GLOBAL NUMBER WITH MSN

An ISDN global number with multiple subscriber number (MSN).

28485 MULTIPLE SUBSCRIBER NUMBER

Multiple subscriber number (MSN).

28486 NOT AN ANALOGOUS SUBSCRIBER

The subscriber is not an analogous subscriber.

28487 NOT AN ISDN GLOBAL SUBSCRIBER

The subscriber number is not an ISDN global number. This situation arises e.g. when an attempt has been made to remove multiple sub-scriber numbering from an ISDN subscriber that has no multiple sub-scriber numbering.

28488 NO SUCH MULTIPLE SUBSCRIBER NUMBER

There is no such multiple subscriber number (MSN).

28489 RECORD IS NOT EMPTY

The record is not empty. E.g. when making the space reservation smaller in connection with a facility, it is found out that the record to be released is not empty.

28500 ALL CIRCUITS CANNOT BE DELETED

All circuits can not be deleted from a circuit group without deleting the whole circuit group.

28501 CIRCUIT GROUP IN ROUTE

The circuit group is in a route.

28502 TOO MANY CIRCUITS

An attempt has been made to add circuits to the circuit group, over the allowed maximum number.

28503 ORDINAL NUMBER INVALID

The ordinal number is too big.

32777 TEST EQUIPMENT RESERVATION TIME-OUT

The time limit of test equipment reservation has expired.

42755 SPARE UNIT AND DISK UPDATE FAILURE

The updating of the CHPARA file both in the spare unit and in the OMU disk has failed. Try again after a while.

42756 SPARE UNIT IN RESTART STATE

The command has not been executed as the unit is in the SP-RE or SP-UP state. Try again later.

Page 542: DX Error Messages

542 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43010 SPACE NOT RESERVED

The updating of the CSCONF file in the OMU disk has failed. Copy the CSCONF file from the active unit to the OMU disk by using the command DFC.

43013 MODE FOR CHARGING DATA COPYING IS INCORRECT

The command execution is allowed only when the charging data copying from disk to tape has been defined to be interrupted. Interrupt the charging data copying with the command GXM:INT; and retry.

43015 START FILE IN INCORRECT STATE FOR OPERATION

The restart of the charging data copying from disk to tape has failed since the starting of the copying from the point defined in the command is not allowed. If the first of the disk files from which the charging data is to be recopied to the tape is in the state WRITE, READ, or RESERVED, the copying is not started. Retry the restart from another point.

43016 CHARGING FILE COPYING BUSY

The command has been given before the previous copying task has been completed. Wait for the completion of the previous task. After the copying has been completed, a NOTICE-type alarm COPYING OF CHARGING FILE COMPLETED is printed out on the alarm printer.

43017 RESTART NOT POSSIBLE: ALL FILES ALREADY RESERVED

An attempt has been made to restart the copying of charging data from disk to tape although all disk files are full. Restart is unnecessary as the charging data would be copied to tape in any case.

43020 COMMAND NOT ALLOWED WHILE DIRECT STORING ACTIVE

When performing direct storing from the RAM of the STU to tape, the simultaneous copying from disk to tape is not possible. Interrupt direct storing by defining the direct storing as totally prohibited or allowed only in fault conditions. The definition of the direct storing is performed with the command GXX. Retry the command which produced the error print-out.

43021 TAPE STORING NOT PROCEEDING NORMALLY IN OMU

The command execution is not started if no acknowledgement to the previous storing task is received from the OMU. Check the states of the tape drives. The tape drives should be in the state WO-BU and the tapes should have the files opened.

43022 FILE CREATION NOT READY

An attempt has been made to open a file the creation of which is in prog-ress.

43023 COPY MESSAGE NEGATIVE ACKNOWLEDGEMENT

Check sum on a copy message is erroneous.

43024 BLOCK LOAD HALTED DUE TO EXCESSIVE CHECK SUM ERRORS DURING TRANSFER

Page 543: DX Error Messages

DN987378Issue 24-0

543

General Error Messages of System DX error messages

Id:0900d8058077e097

The loading of a file load block is interrupted, since the number of negative acknowledgements to the transfer messages in data transfer has exceeded the allowed number.

43025 BLOCK LOAD HALTED DUE TO EXCESSIVE TIME-OUTS DURING TRANSFER

The loading of a file load block has interrupted, since the time limit of data transfer has expired too many time.

43026 LOADING HALTED BECAUSE OF TIME-OUT

The file loading is interrupted, since the time limit of data transfer has expired too many times.

43027 SOURCE UNIT NOT READY

The source unit is in such a state that the loading is not possible.

43028 UNMATCHED COPY MESSAGE

Automaton data of the message copy_message_s (or copy_direct_s); the file or message number, among others, is not what was exptected.

43032 PROGRAM BLOCK IN FAILED FIELDS HAS NO RESOURCES FOR REQUESTED TASK

A program block participating in the task execution has not necessary resources (e.g. available automatons).

43033 UPDATE REQUEST HAS NOT RIGHT AMOUNT OF DATA

The update request does contain the rigth amount of data (e.g. if there must be a multiple number of bytes in the record update request, as compared to the length of the record).

43034 FATAL ERROR IN PROGRAM BLOCK GIVEN IN FAILED FIELDS

The program block given in the message does not function correctly.

43035 UPDATE REQUEST VIOLATES RECORD BOUNDARIES

A request to update a bit map file violates record boundaries.

43036 ERROR IN SENDING A MESSAGE

The message sending has failed; the operating system status is other than "succeeded".

43038 NONEXISTENT SYSTEM

The NECONF file does not contain information on the searched system.

43039 INCORRECT FILE HEADER

The file header is incorrect.

43040 FUNCTION RESULT AREA TOO SMALL

The result of the function does fit into the area reserved for it.

43041 FILE CONTENTS ARE INCONSISTENT

The file is temporarily or permanently in an inconsistent state. E.g. the file update is not completed.

43042 WARM-UP REQUEST FOR DATA SEGMENT IS MISSING

The warm-up request starting message according to the transmission protocol, is missing or it has not been sent.

Page 544: DX Error Messages

544 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43043 TOO MANY WARM-UP REQUESTS RECEIVED

The number of warm-up messages defined in the starting message has been exceeded.

43044 WUPMAN RESOURCE ERROR

Some of the resources needed by WUPMAN is missing, therefore, WUPMAN can not continue functioning.

43046 MESSAGE TRANSFER FAILURE

The message transfer has failed. The MML programs output on the next line, as auxiliary information, a text that can be defined in the own text file of the MML program. An example of auxiliary information: COMMU-NICATION ERROR WITH SCFPRO OF CM UNIT.

43047 FILE OPERATION ERROR

A file operation has failed. The MML programs output as auxiliary infor-mation a more detailed reason for the failure on the next line. An example of this kind of output: /*** FILE OPERATION ERROR ***/ /*** ERROR IN READING DSNFIL FILE OF CM UNIT ***/

43048 INCOMPATIBLE MODULE STATE

The working state of the subscriber module is not required. The MML programs output auxiliary information on the next line. An example of auxiliary information: 1 - 54 MODULE STATE MUST BE WO-EX

43049 CCS CIRCUIT NONEXISTENT

The CCS circuit does not exist.

43050 SIGNALLING POINT NONEXISTENT

The signalling point does not exist.

43051 CIRCUIT GROUP NONEXISTENT

The circuit group does not exist.

43052 INCORRECT TYPE OF CIRCUIT GROUP

The type of the circuit group is incorrect. The circuit group types in use are: 0H = external, switched 1H = external, semipermanent 2H = inter-nal, switched 3H = internal, semipermanent

43053 PCM NOT EQUIPPED

The PCM circuit is not equipped. The circuit is not defined in the PCMCON file.

43055 DESTINATION NONEXISTENT

The destination is not defined in the DSNFIL file.

43056 SUBSCRIBER MODULE NOT IN USE

The subscriber module is not in use.

43057 SUBSCRIBER LINE NOT CONNECTED

The subscriber line is not connected to the subscriber module.

43058 MESSAGE SENT TO SPARE UNIT

Page 545: DX Error Messages

DN987378Issue 24-0

545

General Error Messages of System DX error messages

Id:0900d8058077e097

The message is sent to the passive unit. The MML programs output as auxiliary information the unit to the passive unit of which the messge was sent.

43059 CONTRADICTORY DATA: CONNECTED AND EXTENSION UNEQUIPPED

The DSDHAN MML program tries to update the SMALCO file to contain information: line connected, extension unequipped.

43060 UNIT UPDATE FAILURE

The unit update has failed. The MML programs output as auxiliary infor-mation the unit the update of which failed. An example of auxiliary infor-mation: UPDATING PASSIVE SIDE OF CM FAILED

43061 ALTERNATIVE OF DESTINATION EXISTENT

The alternative of the destination already is in use.

43062 ALTERNATIVE OF DESTINATION NONEXISTENT

The alternative of the destination does not exists.

43063 PREVIOUS ALTERNATIVE OF DESTINATION NONEXISTENT

There is no previous alternative to the destination. The alternatives must be filled in strict order.

43065 CHARGING NONEXISTENT

There is no charging record in the CRFILE file.

43066 CHARGING INDEX NONEXISTENT

There is no charging index record in the CRNANA file.

43067 SUBDESTINATION NONEXISTENT

The subdestination does not exist in the CMORGR-file.

43068 ANALYSIS EXISTENT

The analysis already exists.

43069 ANALYSIS NONEXISTENT

The analysis does not exist. The number of the analysis tree or the com-pletion of the analysis in incorrect.

43070 ANALYSIS SHORTER

The existing analysis is shorter than the given analysis.

43071 ANALYSIS LONGER

The existing analysis is longer than the given analysis.

43072 FREE TREES NOT FOUND

Free analysis starting trees have not been found.

43073 HUNDRED/THOUSAND GROUP ALREADY EXISTENT

The hundred/thousand group is already created.

43074 HUNDRED GROUP NOT IN THOUSAND GROUP

The hundred group does not belong to the thousand group.

43075 HUNDRED/THOUSAND GROUP NONEXISTENT

The hundred/thousand group is not created.

Page 546: DX Error Messages

546 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43076 HUNDRED/THOUSAND GROUP RESERVED

The hundred/thousand group is reserved.

43077 SUBCRIBERS LEFT IN HUNDRED GROUP

There are subscribers left in the hundred group.

43078 SPECIAL ROUTE NONEXISTENT

The special route is not created.

43079 ROUTE NONEXISTENT

The route is not created.

43080 FACILITY CONTROL EXISTENT

The facility control exists.

43081 FACILITY CONTROL NONEXISTENT

The facility control does not exist.

43082 SPECIAL ROUTE EXISTENT

The special route is created.

43083 INCORRECT ROUTE TYPE

The type of the route is incorrect. The available route types are: 00 = external, switched 01 = external, semipermanent 02 = internal, switched 03 = internal, semipermanent

43084 INCORRECT CIRCUIT

The circuit is not defined.

43085 ROUTE ALREADY EXISTENT

The route is already created.

43086 CIRCUIT GROUP ALREADY EXISTENT

The circuit group already exists.

43087 TOO MANY CIRCUIT GROUPS ON ROUTE

The circuit group can not be added to the route, because the maximum number of circuit groups on a route is eigth, and they are already created on the route.

43088 ONLY ONE CIRCUIT GROUP LEFT ON ROUTE

There is only one circuit group left on the route. The last circuit group on the route can not be deleted, instead, the whole route must be deleted.

43089 CIRCUIT GROUP ALREADY EXISTENT ON ROUTE

The circuit group is already created on the route.

43090 ADDITIONAL FACILITIES

The subscriber or extension group has facilities requiring an additional information record.

43091 NO ADDITIONAL FACILITIES

The subscriber or extension group has no additional facilities.

43092 UNKNOWN ABBREVIATED NUMBER

The abbreviated number is unknown.

Page 547: DX Error Messages

DN987378Issue 24-0

547

General Error Messages of System DX error messages

Id:0900d8058077e097

43093 NO ABBREVIATED DIALLINGS

The subscriber has not the abbreviated dialling facility, in other words, space reservation for abbreviated diallings has not been made.

43094 NO FIXED DESTINATION CALL

The subscriber has not the fixed destination call facility.

43095 NO CALL DIVERSION

The subscriber or the group call number has not the call diversion facil-ity.

43096 NO NUMBER REPETITION

The subscriber has not the number repetition facility.

43097 INCORRECT ABBREVIATED NUMBER

The abbreviated number is invalid. For example in connection with PREFIX abbreviated dialling, a one-digit abbreviated number is forbid-den, if a space reservation has earlier been made for two-digit abbrevi-ated numbers beginning with the same digit.

43098 NOT AN ISDN SUBSCRIBER

The subscriber is not an ISDN subscriber.

43099 NO FREE RECORD IN FILE

The file has no free records when an attempt has been made to reserve a record in the file.

43100 GROUP CALL NUMBER WITHOUT POSITION NUMBER

The subscriber number is a group call number without position number.

43101 SPECIAL DAY ALREADY EXISTS

The special day already exists in the special day file (SPEDAY).

43102 SPECIAL DAY FILE FULL

The special day file (SPEDAY) is full.

43103 NONEXISTENT SPECIAL DAY

The special day is not found in the special day file (SPEDAY).

43104 CHANGE GROUP ALREADY EXISTS

The change group alreadry exists in the change group file (CHNGRO).

43105 NONEXISTENT CHANGE GROUP

The change group does not exist in the Change Group File (CHNGRO), or not all day classes are defined for the required change group.

43106 NONEXISTENT CHANGE TIME

The change time does not exist in the change group in question, in the change group file (CHNGRO).

43107 CHANGE TIME ALREADY EXISTS

The change time already exists in the change group in question, in the change group file (CHNGRO).

43108 ALL CHANGE TIMES IN USE

All the change times in the change group are already in use.

Page 548: DX Error Messages

548 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43109 CHARGING ZONE ALREADY EXISTS

The charging zone already exists in the charging zone file (CHRZON).

43110 NONEXISTENT CHARGING ZONE

The charging zone does not exist in the charging zone file (CHRZON).

43111 NOT ENOUGH FREE CHARGE RATE RECORDS

There are not enough free records in the charge rate value file (CHVALU).

43112 CHANGE GROUP NOT FOUND

The change group is not found from any charging zone.

43113 EXPECTED MORE DIALLING

The given subscriber number is too short, because of which the analysis can not be completed. In connection with abbreviated dialling, the second digit of a two-digit abbreviated number is needed.

43115 NO CALL TRACING

The subscriber has not the call tracing facility.

43116 NO OPERATOR FACILITY

The operator facility has not been defined for the extension or sub-scriber number; it is not an operator, supervisor or service number.

43117 NO A-SUBSCRIBER RESTRICTION

The subscriber or the group call number has not the calling subscribers restricted facility.

43118 NO REGISTERED B-SUBSCRIBER NUMBER

The subscriber has not registered the B-subscriber number, even though the subscriber has the facility (space reservation for the B-number has been made). The facilities in question are abbreviated dial-lings, fixed destination call and number repetition.

43119 NO REGISTERED C-SUBSCRIBER NUMBER

The subscriber has not registered the C-subscriber number for call diversion, even though the subscriber has the facility (space reservation for the C-number has been made).

43120 NUMBER NOT ON LIST

The number is not on the list. E.g. the A-subscriber number is not among the A-subscriber numbers that are allowed to call the B-sub-scriber.

43121 NO KEYWORD

No keyword is defined for the subscriber.

43122 NO OUTGOING CALL BARRING ACTIVATED BY SUBSCRIBER

The subscriber has not outgoing call barring activated by subscriber.

43123 NO INCOMING CALL BARRING ACTIVATED BY SUBSCRIBER

The subscriber has not incoming call barring activated by subscriber.

43124 PAY PHONE LINE

The extension is defined as payphone line.

Page 549: DX Error Messages

DN987378Issue 24-0

549

General Error Messages of System DX error messages

Id:0900d8058077e097

43125 ONLY SPACE RESERVED

Only space reservation for the facility has been made.

43126 SPACE ALREADY RESERVED

Space reservation for the facility has already been made.

43127 FACILITY NOT USED IN THIS EXCHANGE

The facility is not activated in this exchange. It does not belong to the delivery.

43128 GROUP CALL WITH ADDITIONAL FACILITIES

A group call number for which additional facilities has been defined.

43129 GROUP CALL WITHOUT ADDITIONAL FACILITIES

A group call number with no additional facilities.

43130 GROUP CALL NUMBER WITH ABBREVIATED DIALLING

A group call number with the abbreviated dialling facility.

43131 GROUP CALL NUMBER WITHOUT ABBREVIATED DIALLING

A group call number with no abbreviated dialling facility.

43132 ANALOGUE SUBSCRIBER

The subscriber is an analogue subscriber.

43133 ISDN SUBSCRIBER

The subscriber is an ISDN subscriber.

43134 CIRCUIT STATE CHANGE NOT POSSIBLE

The circuit is in an incorrect working state. E.g. the state transition from state NU-US to WO-EX can not be made directly.

43135 INCORRECT BLOCK SIZE OF FILE

The file block size has been defined incorrectly. For table format files, the block size must be a multiply of the record size, and for all files, smaller than the file size. If the file is block loaded or block check sums have been defined for it, the block size must be other than zero.

43137 SERVICES NONEXISTENT

Additional services do not exist. The type or index of services given in the inquiry has been illegal.

43138 CALL NUMBER EXISTENT

A call number has already been defined for the circuit group/PCM-circuit.

43139 CALL NUMBER NONEXISTENT

No call number has been defined for the circuit group/PCM-circuit.

43140 INCORRECT RSS INDEX

The index of the remote subscriber stage (RSS) is incorrect.

43141 INCORRECT SUB INDEX IN RSS

When creating or deleting a remote subscriber module or its PCM circuit, an attempt has been made to read further than field SUBC_7_INDEX in the record of REMCON.

Page 550: DX Error Messages

550 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43142 INCORRECT PCM INDEX IN RSS

When creating or deleting a PCM circuit of a remote subscriber module, an attempt has been made to point to outside of field PCM_3_INDEX of the REMCON record.

43143 CIRCUIT EXISTENT

SCFPRO program block generates this error code if the FAMILY_ID field of the PCMCON file is different from zero when creating a PCM circuit.

43144 MODULE EXISTENT

SCFPRO program block generates this error code when there are sub-scriber data in files MODULE, MDROUT and SBDIND; that is, when there exists a subscriber module.

43145 PCM CIRCUIT NONEXISTENT

SCFPRO program block generates this error code when the FAMILY_ID field of file PCMCON is zero when deleting, modifying or interrogating a PCM circuit.

43146 UNIT EXISTENT

The unit to be created has already been created.

43147 NON EXISTENT UNIT

The computer unit (type and index) that is searched for, is not found from the file (e.g. when scanning the file).

43148 SUBSCRIBERS LEFT IN MODULE

SCFPRO program block has attempted to delete a subscriber module where there still are subscribers left.

43149 PCMCON MB ADDRESS NOT FOUND

SCFPRO program block cannot find the PCM circuit given in the message bus address.

43150 PCMCON FAMILY NOT FOUND

SCFPRO program block cannot find the PCM circuit data in the PCMCON file on the basis of the given FAMILY_ID.

43151 PCMCON UNIT TYPE ERROR

SCFPRO program block generates this error code when the given unit maintenance type is none of the following: AONU, MFCU, PBRU, CNFC, DATN, SUB, SUBR, ETS. (The list may be subject to changes.)

43152 PCMCON INFOBYTES NOT FOUND

SCFPRO program block cannot find the primary PCM circuit of the sub-scriber module or the PCM circuit of the maintenance unit given.

43153 CHARGE RATE FILE (CRRATE) NOT UPDATED

The update of the charge rate file (CRRATE) in the CM/CAC has failed due to file error or file addressing failure.

43154 CHARGE RATE FILE (CRRATE) DISTRIBUTION FAILED

Page 551: DX Error Messages

DN987378Issue 24-0

551

General Error Messages of System DX error messages

Id:0900d8058077e097

The distribution of charge rate file (CRRATE) from the central memory to other units has failed. In addition, the MML program outputs the units to which the distribution failed.

43155 NO SPACE IN FILE

There are no free records in the file.

43156 COUNTERS ALREADY CREATED

The counters have already been created once.

43157 COUNTERS ALREADY DESTROYED

The counters have already been destroyed.

43158 NO COUNTERS FOR CIRCUIT

No circuit-specific counters have been defined for the circuit.

43159 GROUP CALL NUMBER AND EXTENSION OF HUNTING GROUP

An extension that simultaneously is a member of another group, has been defined as a group call number.

43160 SUBSCRIBER NUMBER ALREADY ON LIST

The subscriber number has already been defined on the list (e.g. an attempt has been made to add the A-subscriber number again on the list of subscriber numbers that are allowed to call the B-subscriber).

43161 CONNECTION NOT BARRED

The connection is not barred.

43162 CIRCUIT HAS ANOTHER CALL

The circuit has another call.

43163 CIRCUIT NOT CONNECTED

The circuit is not connected.

43164 COMMUNICATION WITH XXXSIG FAILED

Message exchange with XXXSIG has failed.

43165 FACILITY LIMIT EXCEEDED

The maximum number of the facility has been exceeded.

43166 SUBSCRIBER HAS BARRED CONNECTIONS

The subscriber has barred connections.

43167 REPORT FILES DIFFER

The report file of call tracing is different in the active and passive unit.

43168 INCORRECT UNIT STATE

The unit state is such that no changes in the unit can be allowed.

43169 NO CONNECTION

There is no connection.

43170 PCM COUNTERS NOT DELETED

The counters of the PCM circuit have not been deleted since the circuit belongs to more than one circuit group.

43171 NO CIRCUIT CHARGING

Page 552: DX Error Messages

552 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

There is no circuit-specific charging.

43172 END OF FILE

The end of the file.

43173 FILE CONTINUES

The file continues.

43174 PCM NUMBER GREATER THAN OR EQUAL TO NUMBER OF PCMCON FILE RECORDS

The PCM number is greater than or equal to the number of records in the PCMCON file. If the program block is able to, it returns the number of the file in question which can be output by the MML program. The output of the file name can be necessary, as well.

43175 INCORRECT RECORD SIZE OF FILE

The size of the record is incorrect.

43176 RECORD DISTRIBUTION FAILURE

The distribution of the record to other units has failed.

43177 INCORRECT MODIFYING INFO OF PCMCON

The object of modification in the record of the PCMCON file is given incorrectly.

43178 INCORRECT SUBSCRIBER MODULE TYPE

The type of the subscriber module is incorrect.

43179 FILE DISTRIBUTION FAILURE

An error has occurred in the file distribution.

43180 MODULE NOT CREATED

The module has not been created.

43181 DIFFERENT BIT MAPS IN SBSDAT AND SBMDAT FILES

There are different bit maps in the SBSDAT and SBMDAT files.

43182 FILE ERROR IN ASCHAN FILE

There is a file error in the ASS channel file (ASCHAN).

43183 INCORRECT OBJECT INDEX

Incorrect object index. In messages the object to be treated (e.g. a thing that must be modified) is indicated with an index, and if the value of the index is incorrect, this errror code will be returned.

43184 FILE ERROR IN MODULE FILE

There is a file error in the module file (MODULE).

43185 FILE ERROR IN MODROU FILE

There is a file error in the MODROU file.

43186 FILE ERROR IN SBSIDX FILE

There is a file error in the SBSIDX file.

43187 NO ANSWER FROM REQMAN

REQMAN did not respond within time supervision.

43188 DISC UPDATING FAILED

Page 553: DX Error Messages

DN987378Issue 24-0

553

General Error Messages of System DX error messages

Id:0900d8058077e097

REQMAN has replied with an error status.

43189 ETTABL IS FULL

The ET unit table (ETTABL) is full.

43190 ET IS SPECIFIED EARLIER IN ETTABL

The ET unit already is in the ETTABL file.

43191 ET IS NOT SPECIFIED

The ET or PET unit is not found in the SCDFLE or ETTABL file.

43192 ET WORKING STATE IS NOT SE-OU

The ET unit can not be removed since it is an incorrect working state.

43194 NO ANSWER FROM ETFPRO

The ETFPRO program block has not answered within time supervision.

43195 NO ANSWER FROM ET CONTROLLING UNIT

The ERATES program block in the unit supervising the ET unit has not answered within time supervision.

43196 PERMANENT MEASUREMENT IN EXECUTION

A permanent measurement is in progress.

43197 TEMPORARY MEASUREMENT IN EXECUTION

A temporary measurement is in progress.

43198 PERMANENT AND TEMPORARY MEASUREMENT IN EXECUTION

A permanent and temporary measurement are in progress.

43199 CHECK SUM ERROR IN MESSAGE

The check sum in a message is incorrect.

43200 DISK UPDATE QUEUE CORRUPTED

The disk update queue is out of order.

43201 DISK UPDATE QUEUE FULL

The disk update queue is full.

43202 INVALID REQUEST

In the waiting chain of the disk update queue, there is not the udate request given in the message.

43203 MAXIMUM COUNT OF CIRCUIT GROUPS TO SIGNALLING POINT EXCEEDED

There are too many circuit groups to the same signalling point.

43204 IOAFIL RECORD NOT ACCESSIBLE

The given record of the IOAFIL file cannot be accessed.

43205 IOAFIL RECORD NUMBER TOO BIG

The record index given points to the outside of file IOAFIL.

43206 IOAFIL RECORD COUNT NOT FOUND

It is not possible to define the number of records in the IOAFIL file.

43207 CCSPCM ALREADY IN USE

CCSPCM already is in use.

Page 554: DX Error Messages

554 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

43208 CIRCUIT GIVEN MORE THAN ONCE (2)

The same circuit is given more than once.

43209 CIRCUIT TYPE INVALID

The circuit is of an incorrect type, e.g. an attempt has been made to add a circuit defined for line signalling to a CCS circuit group.

43210 CIRCUIT GROUP OUTGOING

The circuit group is outgoing.

43211 CIRCUIT BUSY

The circuit is busy.

43212 BUFFER ALLOCATION FAILED

The buffer allocation has failed.

43213 SERVICE NONEXISTENT

The service information octet does not exist.

43214 NOT SAME PCM NUMBERS

The given circuits are not of the same PCM circuit in case of common channel signalling.

43215 MML TEXT FETCHING ERROR

The MML text is not found.

43217 ROUTE IS NOT EXTERNAL

The route is not external.

43218 ANALYSIS TREE NONEXISTENT

The analysis tree has not been created.

43219 NO PERMANENT MEASUREMENT IN ACTION

A permanent measurement is not in prgress.

43220 PERMANENT MEASUREMENT HAS NOT YET STARTED IN AFS-S

A permanent measurement has not yet started in the AFS-S plug-in unit.

43221 NO MEASUREMENTS IN HISTORY

No measurement results are found from the history data.

43222 NO ANSWER FROM AFS-S

The AFS-S plug-in unit does not answer.

43223 MAXIMUM NUMBER OF MEASUREMENTS ALREADY EXISTS

The maximum number of measurements has been defined.

43224 NO SUCH MEASUREMENT

No measurement has been defined with the parameters in question.

43225 PERMANENT MEASUREMENT ALREADY ABORTED

A permanent measurement has already been interrupted.

43226 D-CHANNEL SYSTEM NONEXISTENT

The D-channel system has not been found.

43300 NUMBER MODIFICATION EXISTS

Page 555: DX Error Messages

DN987378Issue 24-0

555

General Error Messages of System DX error messages

Id:0900d8058077e097

The number modification already exists.

43301 NUMBER MODIFICATION NONEXISTENT

The number modification does not exist.

57345 WARMING OF UNIT FAILS DUE TO UNIT OVERLOAD

The warm-up has not succeeded within the given time (or in the given state), because the application performing the warm-up is not often enough in a state allowing the warm-up.

57346 VALUE REQUIRED BY TASK EXCEEDS GIVEN LIMIT

A parameter given in the task exceeds the value of a constant given as a program parameter.

57347 FAMILY HAS NOT SENT ALL OF ITS WARM-UP REQUESTS

A family to be warmed up has not sent all the warm-up requests when starting the warm-up.

57348 PROGRAM HAS CHANGED

A part of the application to be warmed up has changed so that the appli-cation can not be warmed up.

57349 ERROR HAS OCCURRED IN CO-UNIT

The warm-up has been interrupted due to an error in the co-unit. The error analysis is performed on the basis of the notice given by an appli-cation in the co-unit.

57350 FILE LOADING HAS FAILED

Either the first loading of a dynamically banked file or the loading of a file that is copied afterwards has failed.

57351 FILE WARMING HAS FAILED

The warm-up of a file to be warmed up continuously has failed.

57352 READING FROM OR WRITING INTO SEGMENT HAS FAILED

The limit of a segment has been exceeded (data segment, buffer), or the segment can not be read or written into.

57353 WARMING GROUP IS ERRONEOUS

The number of hands in the hand types defined as a warming group differ from each other.

57360 FAMILY IS NOT FOUND

The family to be warmed up is not found.

65504 LOWER LIMIT OF FUNLIB ERROR CODES

The lower limit of FUNLIB error codes.

65509 BAD LOGICAL ADDRESS TYPE

The type of the logical address is incorrect.

65510 BAD GROUP ADDRESS TYPE

The type of the group address is incorrect.

65511 ACKNOWLEDGER FOR GROUP ADDRESS NOT FOUND

No acknowledger for the group address is found.

Page 556: DX Error Messages

556 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

65512 GROUP ADDRESS NOT FOUND

The group address for a unit is not found.

65513 CLASSIFICATION ON FUNCTIONAL UNITS FAILED

The initialization of the functional unit classification table has failed.

65514 COMPUTER ADDRESS TABLE UPDATING FAILED

The update of the computer address table has failed.

65515 MB INDEX TABLE UPDATING FAILED

The update of the MB index table has failed.

65516 TYPE INDEX TABLE UPDATING FAILED

The update of the type index table has failed.

65518 BAD COMPUTER ADDRESS TABLE SEGMENT

Pointing to the computer address table has failed.

65519 BAD SCDFLE SEGMENT

Pointing to the SCDFLE file has failed.

65531 NONEXISTENT UNIT TYPE

The unit type does not exists in the configuration in question.

65532 UNIT IS NOT COMPUTER UNIT

The unit is not a computer unit, or the unit does not exist in the configu-ration in question.

65533 UNIT INDEX BEYOND LIMITS OF SCDFLE

The unit does not exist in the configuration in question. Units of the given type can exist with a greater index value.

65534 UNIT NONEXISTENT

The unit does not exist in the configuration in question. Units of the given type can exist with a greater index value.

196609 UNKNOWN SUBSCRIBER

Given subscriber does not exist in the database.

196610 SUBSCRIBER ALREADY EXISTS

Subscriber already exists in the database.

196613 UNKNOWN SUBSCRIBER

The given subscriber does not exist in the database.

196615 UNKNOWN EQUIPMENT

The equipment is unknown.

196616 BASIC SERVICE CODE AND BASIC SERVICE CODE INDEX MISMATCH

The basic service code does not have the appropriate basic service code index defined for it.

196617 TD1 CAN NOT BE PRIMARY BASIC SERVICE CODE

TD1 can not be primary basic service code.

196618 BASIC SERVICE NOT PROVIDED

Page 557: DX Error Messages

DN987378Issue 24-0

557

General Error Messages of System DX error messages

Id:0900d8058077e097

The bearer service is not provided.

196619 BASIC SERVICE NOT PROVIDED

The tele service is not provided.

196621 CALL BARRED

Call is barred.

196623 CUG REJECTED

Closed user group was rejected.

196624 ILLEGAL SUPPLEMENTARY SERVICE OPERATION

The attempted supplementary service handling operation is illegal.

196625 SUPPLEMENTARY SERVICE NOT PROVIDED

The supplementary service is not provided.

196626 SUPPLEMENTARY SERVICE NOT AVAILABLE

The supplementary service is not available.

196628 SUPPLEMENTARY SERVICE INCOMPATIBILITY

The supplementary services are incompatible.

196631 INVALID TARGET BASE STATION

The target base station is invalid.

196642 DATABASE SYSTEM FAILURE

A database system failure has occurred.

196643 DATA MISSING

Some data is missing in the database.

196644 UNEXPECTED DATA VALUE

An unexpected data value has been found in the database.

196648 TRACING BUFFER FULL

The tracing buffer is full.

196649 TRACING ALREADY ACTIVATED

Tracing has already been activated for the subscriber.

196650 SUBSCRIBER TRACING NOT ACTIVATED

Tracing has not been activated for the subscriber.

200705 BASIC OR SUPPLEMENTARY SERVICE NOT PROVIDED

The basic or supplementary service has not been provided to the sub-scriber.

200706 INCONSISTENT IMSI USAGE

The IMSI is used inconsistently.

200707 INCONSISTENT UPDATE BADGE

The update badge is inconsistent.

200708 PRIMARY BASIC SERVICE

The given service is a primary basic service which must not e.g. be deleted.

Page 558: DX Error Messages

558 DN987378Issue 24-0

General Error Messages of System

Id:0900d8058077e097

DX error messages

200709 FORBIDDEN C NUMBER

C number is forbidden.

200710 INCONSISTENT IMSI AND HMSI

IMSI and HMSI are inconsistent.

200711 NO PRIMARY MSISDN NUMBER

The subscriber has no primary MSISDN number.

200712 SUBSCRIBER ALREADY HAS THIS KIND OF BASIC SERVICE

Subscriber already has the given basic service.

200713 DELETION NOT ALLOWED

Attempted deletion is not allowed in database.

204801 MID ALREADY EXISTS

Virtual subscriber already exists.

204802 UNKNOWN VIRTUAL SUBSCRIBER

Virtual subscriber does not exist.

204803 NOT ATTACHED IMSI

The given IMSI is not attached to a virtual subscriber.

204804 ATTACHED IMSI NOT FOUND

Attached IMSI is not found.

204805 NO VIRTUAL SUBSCRIBERS FOUND

No virtual subscribers are found in database.

208897 ENTRY ALREADY EXISTS

The given IMEI or IMEI series already exists in the equipment identity register.

208898 ENTRY NOT FOUND

The given IMEI or IMEI series cannot be found in the equipment identity register. The given list or IMEI interval does not contain one single IMEI or IMEI series.

208899 ENTRY NOT FOUND IN WHITE LIST

An attempt has been made to create an entry on the grey or black list when the entry does not exist on the white list. In addition, it has been parametrized that "the entry must be on the white list".

208900 ENTRY FOUND IN BLACK LIST

An attempt has been made to create an entry to the grey list when the entry also exists on the black list. In addition, it has been parametrized that "the entry may not be both on the black list and on the grey list at the same time". An attempt has been made to delete an entry from the white list when the given IMEI or IMEI series exists on the black list. In addition, it has been parametrized that "the entry must be on the white list".

208901 ENTRY FOUND IN GREY LIST

An attempt has been made to create an entry to the black list when the entry also exists on the grey list. In addition, it has been parametrized

Page 559: DX Error Messages

DN987378Issue 24-0

559

General Error Messages of System DX error messages

Id:0900d8058077e097

that "the entry may not be both on the black list and on the grey list at the same time." An attempt has been made to delete an entry from the white list when the given IMEI or IMEI series exists on the grey list. In addition, it has been parametrized that "the entry must be on the white list".

208902 ENTRY CONFLICT

An attempt has been made to delete a series which contains several entries.

212993 INVALID ALGORITHM VERSION

The given A3/A8 algorithm version is invalid.