driving innovation. - steris · 2019-04-24 · driving innovation. delivering throughput. from the...
TRANSCRIPT
SPD and OR Solutions
DRIVING INNOVATION. DELIVERING THROUGHPUT.From the people who set the standard for Low Temperature Sterilization.
= MAXIMUM THROUGHPUTSPEED Capacity+
One Integrated Approach to Healthcare.
MAX SPEED AND CAPACITY
Exclusive Cycle Non Lumen Cycle
68 trays per shift60 trays per shift
Unlock the greatest throughput and productivity for your OR, ASC or SPD with V-PRO® Sterilizers. STERIS innovations factor speed, capacity and chamber usage to deliver true maximum throughput, keeping you on schedule, all the time.
MAXIMUM THROUGHPUT
28 minutes, 50 lbs.16 minutes, 11 lbs.
Fast Non Lumen Cycle
The fastest and most productive Low
Temperature Sterilizer in the V-PRO portfolio
50 trays per shift 34 trays per shift
19 minutes, 4 lbs of Non Lumen and Stainless Steel
Lumen Instruments
Fast Cycle
For when space is at a premium, but need
maximum productivity28 minutes, 25 lbs.
N/A
68 trays per shift
A lower total cost of ownership with
outstanding productivity28 minutes, 50 lbs.
Flexible Cycle Lumen Cycle
54 trays per shift 36 trays per shift
Unlock the greatest throughput and productivity for your OR, ASC or SPD with V-PRO® Sterilizers. STERIS innovations factor speed, capacity and chamber usage to deliver true maximum throughput, keeping you on schedule, all the time.
THE V-PRO DIFFERENCEFeatures only available from V-PRO Sterilizers
35 minutes, 24 lbs. 52 minutes, 19.65 lbs.
* Trays per shift is factored by : • 8 hour shift • 19 x 7.5 x 2 PRO-LITETM sterilization tray (VP049) • Time for the specific cycle
24 trays per shift 16 trays per shift
38 minutes, 11 lbs. 60 minutes, 11 lbs.
54 trays per shift 34 trays per shift
35 minutes, 24 lbs. 55 minutes, 19.65 lbs.
MAX INNOVATION
MAXIMUM THROUGHPUT
* Savings based on U.S. Government average contract pricing for V-PRO Sterilizers and STERRAD Sterilizers in 2018** When used in conjunction with Celerity® 20 HP Biological Indicator
INCREASED PRODUCTIVITY. REDUCED EXPENSE.
Up to 50% less consumable cost*
INNOVATIONS PRODUCTIVITY THROUGHPUT
• Maximize devices per load with the most productive cycle claims and the ability to have mixed loads
• Process more stainless-steel lumens than competing
vaporized hydrogen peroxide sterilizers in the Lumen Cycle
- Up to 20 in V-PRO maX and maX 2 Sterilizers, up to 12 in V-PRO s2 and 60 Sterilizers
• Gain flexibility in load contents with the ability to process dual channel flexible scopes and dual and triple channel rigid scopes.
• Increase your speed to process devices, and use less sterilant, with the new Fast and Fast Non Lumen Cycles - both exclusive to V-PRO Sterilizers
20% faster BI read**
Up to 25% less service cost*
Endoscope Endoscope Accessories
Powered Instruments
General Surgical Instruments
Arthroscopes
Bronchoscopes
Choledochoscopes
Cystoscopes
da Vinci® Xi and Si Endoscopes
Hysteroscopes
Intubation Endoscopes
Laparoscopes
Rhinolaryngoscopes
Ureteroscopes
Cameras
Cannulas
Fiber Optic Light Cables
Obturators
Sheaths/ Adapters/ Bridges
Batteries
Chucks
Drills
Handpieces
Saws
Curettes
Forceps
Retractors
Scissors
Pouches
Rigid Containers
Trays
Wraps
Full list of validated devices: steris.com/devicematrix
MAX COMPATIBILITY
Setting the standard to ensure V-PRO Sterilizers work with the widest range possible
of medical devices and materials, through a gentle, non-plasma process.
Bougies
Defibrillation Paddles
Flow Probes
Gonio/ Vitrectomy Lens
Laryngoscope Blades & Handles
Opthalmic
Transducers
Ultrasound Probes
Ceramics
Copper
Diamond
Platinum
Santoprene
Silver
Tungsten Carbide
Unique Materials
Other DevicesPackaging
MAX SIMPLICITY
Stay on schedule with the fastest
BI release in the industry — just 20 minutes with
CelerityTM 20 HP Bological Indicator
Now available for V-PRO maX 2 and s2
Sterilizers, the new Smart Cup is designed
to help save time and expense
from wasted sterilant.
Receive fast and reliable indication of sterilant penetration with the
Celerity™ HP Chemical Indicator
Immediate CI results with
VERIFY® HPU Chemical Indicators and VERIFY® VH202 Indicator Tape
Standardize your process with the same sterilant used
in all V-PRO Sterilizers —
VAPROX® HC Sterilant
MAXIMUM THROUGHPUT
Optimize loading capacity and increase weight capacity in V-PRO Sterilizers
with PRO-LITE™ Sterilization Trays
PCC074
HP Chemical Indicator
VH2O2
Exp. date
REF
QR B
arco
de
TM
PCC074_UNUSED.indd 1 24/09/2018 14:54
Continual InnovationSTERIS has continually added new claims to V-PRO Sterilizers,
at no cost, to keep you at your most productive. To learn more
about the value we’ve added to V-PRO Sterilizers and keep up-to-date
on new claims, visit STERIS.com/vproclaims
*V-PRO s2 Sterilizer only
MAX EASE
Easy to Learn and OperateIntuitive on-screen displays with bold simple icon selections and on-screen instructional videos*
Minimize Aborted CyclesDelayed Start and Moisture Check features save time and money.
V-PRO s2 Instructional Videos
V-PRO maX 2 Sterilizer screen
V-PRO maX 2 Sterilizer screen
STERIS Corporation5960 Heisley RoadMentor, OH 44060-1834 • USA440-354-2600 • 800-548-4873www.steris.com
Document #M4176EN.2019.03, Rev D ©2019 STERIS Corporation All rights reserved.
STERRAD us a registered trademark of Johnson & Johnson Corp.da VInci Xi and Si Endoscopes are a registered trademark of Intuitive Surgical, Inc.
To learn more about V-PRO Sterilizers, contact your
STERIS Representative or visit STERIS.com/VPRO
MAX UPTIME
Four-hour phone response
and 48-hour onsite response
regardless of the primary
service provider
Over 800 service technicians
in North America, with three
technicians assigned to every
account
Flexible service options with no
minimum purchase order for
service
MAXIMUM THROUGHPUT
No tracking system? No problem.
ConnectAssure Technology has a robust interface that allows all the benefits of the software without a facility tracking system.
A holistic, integrated team
of service experts delivering
the highest level of
responsiveness and
technical expertise
in the industry.
Driven by real-time data delivered from your V-PRO maX 2 Sterilizer and Celerity
HP Incubator to your facility’s tracking system, ConnectAssure Technology
allows your staff to focus on what matters most — supporting the OR.
• Complete sterilization records in one place
• Reminders for regular maintenance tasks
• Essential reporting for compliance
• Demonstrate compliance over a defined period
• Eliminate lost or incomplete sterilization records
TRACKING
SY
STEM
COMPLIANCE MADE SIMPLE