drawing schedule social housing schematic design …€¦ · 1x1 & 1x2 bedroom duplex (2 x gold...
TRANSCRIPT
Housing and Public WorksDepartment of
PROJECT NO:
SOCIAL HOUSING
SCHEMATIC DESIGN DRAWINGS
1x1 & 1x2 BEDROOM DUPLEX
(2 x GOLD UNITS)
10 LYNTON STREET
UPPER MT
GRAVATT
MASTER SITE NO: 55989
PROGRAM: HCJP PROGRAMME:
CBRC (HCJP)
C THE STATE OF QUEENSLAND (BUILDING and ASSET SERVICES 2018)
85271
A00.00 COVER SHEET
A00.01 CONTOUR & DETAIL SURVEY
A01.01 DEMOLITION PLAN
A01.02 SITE SETOUT PLAN
A01.03 EXTERNAL WORKS PLAN
A02.01 FLOOR PLAN
A02.02 ROOF PLAN & SECTION
A04.01 ELEVATIONS
A04.02 3D VIEWS
A04.03 STREET VIEWS
A05.01 PARTY WALL INFO.
DRAWING SCHEDULE
DRAWING NO. DRAWING TITLESHEET NO.
0
1
2
3
4
5
6
7
8
9
AERIAL VIEW
A 08.03.19
REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
OUTDOOR SPACES INCREASED
B 27.03.19 BED 2 BATHRM ALTERED
C 01.04.19 HARDSTAND REPLACES TURF NORTH SIDE OF UNITS
D 05.06.19
RB
RB
RB
RB
CD/G01
10
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
85271 SD A00.00 0D
COVER SHEET
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
KP/BH
RB
AG
FEB 2019
FEB 2019
FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
RP86160
PP
Telstra Pits
Telstra Pit
Telstra Pit
Water Valve
FH
49
50
1.0
m H
igh
Blo
ck W
all
Conc.
Drivew
ay
Conc.Driveway
TBM
Screw in Kerb
RL48.350
TBM
Screw in Kerb
RL50.153
Kerb
and C
han
nel
Carport
49.08
49.14
50.2
5
50.16
50.15
50.3
9
50.20
50.23
50.34
50.41
50.43
50.0
6
50.3
1
50.3
4
48.99
R51.5
5R51.4
8
R51.9
3R52.94
R53.24
G51.8
5
T
T
T REMOVE EXISTING TIMBER PALING FENCE
REMOVE EXISTING TIMBER PALING FENCE
REMOVE EXISTING TIMBER PALING FENCE
REMOVE EXISTING TIMBER PALING FENCE
REMOVE EXISTING TREES
REMOVE CONCRETE BLOCK RETAINING WALL.ENSURE THE REMOVAL OF THIS WALL IS CO-
ORDINATED WITH NEW WORK TO AVOID EROSION OR DAMAGE OF NEIGHBOURING PROPERTY
REMOVE EXISTING TREES
REMOVE EXISTING CONCRETE CROSSOVER.
MAKE GOOD
EXISTING TREE / VEGETATION TO REMAIN
REMOVE TREE / VEGETATION
REMOVE STRUCTURE
LEGEND DEMOLITION AND SITE CLEARANCE NOTES
REMOVE ANY REMAINING STRUCTURES ON SITE. CONTRACTOR TO ENSURE
ANY REMAINING FOOTINGS AND OTHER DEBRIS ARE REMOVED FOR SITE
PRIOR TO COMMENCEMENT OF NEW CONSTRUCTION WORK.
- REMOVE ALL VEGETATION, SHRUBS AND TREES UNLESS OTHERWISE
NOTED OTHERWISE TO BE RETAINED OR PRUNED, LOCATION OF TREES
TO BE CONFIRMED ON SITE AT TIME OF CONSTRUCTION.
- FOR ANY EXISTING TREES TO BE RETAINED, HAND CULTIVATE AROUND
TREES AND SHRUBS USING HAND TOOLS AND DO NOT DISTURB THE
TREE ROOTS. CONSTRUCT TEMPORARY TREE PROTECTION AROUND THE
TREE TO BE RETAINED.
- TERMINATE AND CAP OFF EXISTING ELECTRICAL SERVICES TO THE
SATISFACTION OF THE SUPPLYING AUTHORITIES.
- TERMINATE AND CAP OFF ALL EXISTING SERVICES, INCLUDING GAS SERVICES.
- REMOVE SURPLUS GULLY / MANHOLES, GRATING AND TRENCHES.
- REINSTATE ALL KERBS, PATHS, CROSSOVERS TO STREET FRONTAGES TO
SATISFY THE SUPPLYING AUTHORITIES.
- REINSTATE ALL DISTURBANCE TO ALL PROPERTIES AND AREAS, LIAISE WITH
LOCAL AUTHORITIS AND ADJACENT PROPERTY OWNERS AS NECESSARY,
INCLUDING PREVENTATIVE MEASURES.
- REMOVE ALL OF THE EXISTING FENCING ON SITE AND PROVIDE NEW FENCING
AS SHOWN ON EXTERNAL WORKS PLAN
- REMOVE ALL DEMOLISHED MATERIALS AND DISPOSE OFF SAITE (REFER
MANAGEMENT OF FIRE ANTS IN SPECIFICATION)
- LIAISE WITH LOCAL AUTHORITIES TO PROVIDE NEW CONCRETE FOOTPATHS AS
REQUIRED AND INTEGRATE NEW ENTRIES AND DRIVEWAYS.
- MAKE GOOD AND REPAIR EXISTING KERBS, CROSSOVERS, ETC AFTER THE
INSTALLATION OF NEW WORKS.
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
1 : 200
85271 SD A01.01 2D
DEMOLITION PLAN
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
WK/BH
RB
AG
FEB 2019
FEB 2019
FEB 2019
SCALE 1 : 200
DEMOLITION PLAN1
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
100
RP86160
98
RP86160
102
RP86160
PP
Telstra Pits
Telstra Pit
Telstra Pit
Water Valve
FH
Water Meter
49
50
Lowset Rendered House
1.0
m H
igh
Blo
ck W
all
Conc.
Drivew
ay
Driveway
Conc.Driveway
TBM
Screw in Kerb
RL48.350
TBM
Screw in Kerb
RL50.153
Kerb
and C
han
nel
Carport
TREEHt = 2Spread = 1.0Trunk = 0.10Type = NR
49.14
50.2
5
50.16
50.15
50.3
9
50.13
50.01
50.00
50.10
50.09
50.00
50.08
50.11
50.13
50.15
50.20
50.23
50.34
50.41
50.43
R53.20
R54.38
R52.77
R52.89
R54.38
G52.6
5G52.6
5
G52.64 G52.6450.
2950.22
50.33
50.11
50.10
50.04
50.02
50.2650.
11
50.32
50.0
6
50.3
1
50.3
4
48.99
R51.5
5R51.4
8
R51.9
3
R52.94
R53.24
G51.8
5
T
T
T
SE
TB
AC
K
1500
SETBACK
1500
SETBACK
6000
SE
TB
AC
K
4500
MRP
1:4
0 fa
ll
1:40 fall
GB
2 BED UNIT 1
GOLD / FFL 50.200
1 BED UNIT 2
GOLD / FFL 49.300
SE
TB
AC
K
4500
30.570m 90°21"0"
26.547m 90°21"0"
20.1
17m
TO WALL
7410
TO
WA
LL
1860
0°11
'0"
16.0
94m
180°
11'0
"
5.698m315°76'0"
L Y NM O U T H S T R E E T
L Y
N T
O N
S T
R E
E T
- REQUIRED PLANNING SETBACKS SHOWN IN REDDRAWINGS ARE INDICATIVE SKETCH FOR REFERENCE ONLY.
- CONTRACTOR/CONSULTANT TO VERIFY SITE CONDITIONS SHOWN ON THE VDRAWING WITH CONTOUR & DETAIL SURVEY & ACTUAL SITE CONDITIONS.- PARTY WALLS & SLABS: VERIFY DETAIL TO ACHIEVE ACOUSTIC RATING TO COMPLY WITH
NCC. ADJUST O/A BUILDING WIDTH & HEIGHT ACCORDINGLY.- ALL EXPOSED SERVICES & PIPEWORK TO BE CONCEALED PUBLIC VIEW (EG. IN SUITABLE DUCTS/SCREENS. ETC.)- PROPOSED STRUCTURE DOES NOT IMPACT THE
EXISTING SEWER.FLOOD HAZARD MANAGEMENT IS TO BE DESIGNED BY CIVIL ENGINEERS AS REQUIRED.
TOWN PLANNING:YIELD: 1 x 1 & 1 x 2 BEDROOM DUPLEXMAX HEIGHT ALLOWED: 2 STOREY AND 9.5mACTUAL: 4.2m (approx)
AREA CALCULATIONSUNITS (incl. PATIOS, STAIRS & EAVES - 255.04m²
SITE AREA 607.00 m²
MAX. SITE COVER (50%) 303.50m²
AREA CALCULATED 255.04m²
SITE COVER (ACTUAL) 42.02%
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
As indicated
85271 SD A01.02 3D
SITE SETOUT PLAN
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
WK/BH
RB
AG
FEB 2019
FEB 2019
FEB 2019
SCALE 1 : 200
SITE SETOUT PLAN1
TOWN PLANNING
FRONT SETBACKPrimary frontage - 4m to balcony/patio6m to wall
Secondary frontage4.5m to wall
SIDE SETBACKUp to 4.5m in building height: 1.5mUp to 7.5m in building height: 2.0m
Above 7.5m in building height: 2.0m, plus 0.5m for every 3m
REAR SETBACKFor development located on a site with 2 or more street frontages, all common
boundaries with adjoining lots are considered side boundaries.Up to 4.5m in building height: 1.5m
APPLICABLE OVERLAYS
ZONE AREA: Low density Residential zone
KOALA SELF ASSESSMENT & MANAGEMENT PLAN: RequiredDUAL OCCUPANCY: YesAIRPORT ENVIRONS: YesCOMMUNITY PURPOSE NETWORK: Yes
CRITICAL INFRASTRUCTURE & MOVEMENT NETWORK: YesDWELLING HOUSE CHARACTER: YesROAD HEIRARCHY: YesSTREETSCAPE HEIRARCHY: Yes
WATER QUALITY: Climate regions - stormwater management design objectivesNATURAL NHAZARDS RISKS & RESILIENCE: Flood hazard area - Local government Flood Mapping AreaSTRATEGIC AIRPORTS & AVIATION FACILITIES: Wildlife hazard buffer zone
SITE AREA 607m²(Min req'd: 3000m² - will trigger Public Notification)
A 08.03.19
REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
OUTDOOR SPACES INCREASED
B 27.03.19 BED 2 BATHRM ALTERED
C 01.04.19 HARDSTAND REPLACES TURF NORTH SIDE OF UNITS
D 05.06.19
49
50
49.14
50.39
50.06
50.31
50.34
48.99
O NK00
SIK00 PLD
SIK00 PLD
O NK00
O SC00 STUB
O SK00
SIK00 PLDSIK00 PLD
SIK00 PLD NIK00 FD SIK00 FD SIK00 FD
NIFP00 TOP SFP G INW M 00
TPIT00 TPIT00 FH00 TPIT00 TPIT00
TPIT00PPT00
BW 01 .9BLK
SPHT00
TO K01LIP01
SPHT00LIP02TO K02
SPHT00
FN01 1.0W OO DPALINGFN01 1.0W OO DPALINGW M 00FN01 1.0W OO DPALING
SPHT00
TO K02LIP02SPHT00
LIP01TO K01
SPHT00
BW 01 .9BLKBW 01 .9BLK
SPHT00
TO K01LIP01
SPHT00LIP02TO K02
TREENC00 3 1.5 0.10 NRTREENC00 3 1.0 0.07 NR
FN01 1.0W OO DPALINGFN02 1.0W OO DPALINGFN02 1.0W OO DPALING
SPHT00
DW AY01 CO NCDW AY01 CO NC
DW AY01 CO NCDW AY01 CO NC
DW AY01 CO NCDW AY01 CO NCDW AY01 CO NCTO K02LIP02LIP02LIP02LIP02TO K03DW AY01 CO NCDW AY01 CO NCDW AY01 CO NC
DW AY01 CO NCDW AY01 CO NCDW AY01 CO NC
DW AY01 CO NCFN03 1.0W OO DPALINGFN03 1.0W OO DPALING
SPHT00TPIT00 PP00SPHT00
SPHT00SPHT00
TO K01LIP01LIP01LIP01TO K01
SPHT00
BW 01 .9BLKBW 01 .9BLKDW AY02 CO NC
DW AY02 CO NCDW AY02 CO NC
DW AY02 CO NCDW AY02 CO NC
DW AY02 CO NCDW AY02 CO NCDW AY02 CO NCTO K04
TO K04TO K04LIP01LIP01
DW AY02 CO NC
DW AY02 CO NCBW 02 .9BLKBW 02 .9BLK
SPHT00
FN04 1.8W OO DPALINGFN04 1.8W OO DPALING
TO K04LIP01SPHT00
LIP02LIP02TO K03TO K03
TO K03 SPHT00
BW 03 1.7BLKBW 03 1.7BLKBW 03 1.7BLKDW AY03 CO NC
DW AY03 CO NCSPHT00SPHT00DW AY03 CO NCDW AY03 CO NC
DW AY03 CO NCDW AY03 CO NC
DW AY03 CO NCDW AY03 CO NCDW AY03 CO NC
DW AY03 CO NCDW AY03 CO NCDW AY03 CO NCDW AY04 CO NC
DW AY04 CO NCDW AY04 CO NCDW AY04 CO NCDW AY04 CO NC
DW AY04 CO NCDW AY05 CO NCDW AY05 CO NC
DW AY05 CO NCDW AY05 CO NC
DW AY05 CO NCDW AY05 CO NCDW AY05 CO NCDW AY05 CO NCDW AY05 CO NCDW AY05 CO NCDW AY05 CO NC
DW AY05 CO NC
DW AY05 CO NCBW 04 1.0BLK
SPHT00
TO K05 LIP02LIP02LIP02LIP02SPHT00
SPHT00
SPHT00
LIP01TO K04
SPHT00
FN04 1.8W OO DPALING
SPHT00
TO K04LIP01LIP01TO K04
SPHT00
SPHT00
LIP02TO K05
SPHT00
BW 04 1.0BLKBW 04 1.0BLK
SPHT00
TO K05LIP02
SPHT00LIP01TO K04
SPHT00TPIT00TPIT00FH00VA00
TPIL00PP00SIG N01 LYNMO UTH
SIG N02 LYNTO N
TREENC00 4 0.5 0.03 NRTREENC00 3 0.5 0.03 NRTREENC00 6 2.0 0.20 NRSPHT00
TO K04LIP01SPHT00
LIP02TO K05
SPHT00SPHT00
BW 04 1.0BLKBW 04 1.0BLKBW 05 1.0BLK
BW 05 1.0BLK
SPHT00SPHT00
SPHT00
SPHT00
TO K05LIP02LIP02
LIP02LIP02TO K05TO K05TO K05EC01EC01CG 01CG 01TO K06TO K06TO K06TO K06LIP02
LIP02TO K06TO K06LIP02
LIP02TO K06SPHT00BW 05 1.0BLK
BW 05 1.0BLKSPHT00
TO K06
LIP02TREENC00 5 2.5 0.30 NR
TREENC00 5 4.5 0.75 JAC
TREENC00 6 2.5 0.25 NR TREENC00 6 2.5 0.25 NR
SPHT00SPHT00
SPHT00
SPHT00
SPHT00
SPHT00
SPHT00
TO K04
LIP01
LIP01LIP01TO K04TO K07TO K07TO K07CG 02CG 02CG 02EC02EC02 SPHT00
SPHT00SPHT00
SPHT00
SPHT00SPHT00
TO K07LIP01
LIP01TO K07TO K07LIP01
PP00SPHT00LIP01TO K07
TREENC00 4 1.0 0.12 NR
TREENC00 4 2.0 0.15 NRSPHT00TO K07LIP01
LIP01TO K07
TO K07TO K07TO K07LIP01LIP01 TREENC00 5 2.0 0.15 NR
SPHT00
SPHT00DW AY06 CO NCDW AY06 CO NCDW AY06 CO NCDW AY06 CO NC
DW AY06 CO NCDW AY06 CO NCDW AY06 CO NCDW AY06 CO NCTPIT00TPIT00TO K08TO K08TO K08LIP01LIP01
LIP01TO K08
SPHT00
SPHT00
G ARD01G ARD01
G ARD01
TO K08LIP01
LIP01TO K08TO K08
TO K08LIP01
LIP01SPHT00
LIP03TO K09
TO K09TO K09TO K09LIP03LIP03 SPHT00
SPHT00SPHT00LIP03LIP03TO K10TO K10TO K10
TO K10LIP03LIP03TO K10 SPHT00
SPHT00SPHT00
SPHT00
LIP03TO K10TO K10
TO K10LIP03
LIP03
XO VER01
XO VER01
SPHT00
LIP03
LIP03
XO VER01
XO VER01TO K11
TO K11TO K12LIP03LIP03 SPHT00
SPHT00LIP03LIP03TO K12
TO K12LIP03 SPHT00
SPHT00LIP03TO K12TO K12
TO K12TO K12TO K12LIP03LIP03 SPHT00
SPHT00LIP03LIP03TO K13TO K13TO K13
TO K13LIP03LIP03 SPHT00
SPHT00LIP03TO K13
W M 00
EC03EC04FN05 1.2W OO DPALING
FN05 1.2W OO DPALINGDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCEC04EC03DW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NC
DW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCDW AY07 CO NCFN06 1.2W OO DPALING EC05EC06
EC06EC05EC05FN06 1.2W OO DPALINGFN07 1.2W OO DPALING EC07EC07
SEW MH00TPIT00
PP00 STAY
VA00 VA00VA00
TPIT00TPIT00
TPIT00
SEW MH00
G PITNC01G PITNC01
G PITNC01
G PITNC01G PITNC02G PITNC02G PITNC02G PITNC02IL00 300RCP IL00 300RCPIL00 375RCP
FH00VA00
TPIT00
TPIT00
W M 00
M H01 AIRVLVM H01 AIRVLVM H01 AIRVLVM H01 AIRVLV
PP00
TREENC00 2 1.0 0.10 NR
TREENC00 3 1.5 0.15 NR
TREENC00 3 1.5 0.10 NR
TREENC00 2 1.2 0.15 NR
TREENC00 3 1.0 0.10 NR
TREENC00 3 1.0 0.10 NR
TREENC00 3 1.5 0.15 NR
TREENC00 3 1.5 0.15 NR
PP00
EC07DW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NC
DW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCDW AY08 CO NCBW 06 .7W OO DBW 06 .7W OO D
BW 06 .7W OO D
EC10EC11
EC11 EC11EC11EC11EC10EC10EC10EC10BW 07 .7W OO D
BW 07 .7W OO DEC10EC11
EC11EC10BW 07 .7W OO DFN10 1.2W OO DPALING SPHT00EC10EC11
EC11 EC11EC11EC11EC11EC11EC10EC10EC12EC12FN10 1.2W OO DPALINGFN11 1.2W OO DPALING EC12EC12
EC10EC11
EC11EC10FN11 1.2W OO DPALINGDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NC
DW AY09 CO NC
DW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY09 CO NCDW AY10 CO NCDW AY10 CO NCDW AY10 CO NCDW AY10 CO NCEC13EC14
EC14EC13
EC13EC13EC15EC15EC14 EC14EC14EC14
EC14EC15SPHT00EC15EC14DW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NC
DW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NCDW AY12 CO NCEC16EC17FN11 1.8W OO DPALING
FN11 1.8W OO DPALINGEC16EC17
RO O F01RO O F01
RO O F01RO O F02
RO O F02RO O F02 RO O F03RO O F03RO O F03 BLDG 01 LSETRENDEREDBLDG 01 LSETRENDEREDBLDG 01 LSETRENDERED
G UTTER01
G UTTER01G UTTER01 G UTTER01
FN12 1.5W OO DPALINGFN12 1.5W OO DPALINGFN13 1.5W OO DPALING
FN13 1.5W OO DPALINGFN13 1.5W OO DPALINGG ARD02
G ARD02
DW AY15 CO NCDW AY15 CO NCDW AY15 CO NCDW AY15 CO NCDW AY15 CO NCDW AY15 CO NCDW AY15 CO NCSPHT00
SPHT00
SPHT00
SPHT00
W M 00
W M 00
FN14 1.5W OO DPALINGFN14 1.5W OO DPALING
SEW MH00
FN04 1.5W OO DPALING SPHT00SPHT00FN04 1.5W OO DPALINGFN04 1.5W OO DPALINGSPHT00SPHT00FN04 1.5W OO DPALINGFN04 1.8W OO DPALING
FN16 1.8W OO DPALINGFN16 1.8W OO DPALING
FN16 1.3W OO DPALING SPHT00
SPHT00SPHT00
SPHT00FN16 1.3W OO DPALINGFN16 1.3W OO DPALING SPHT00
SPHT00FN16 1.3W OO DPALINGDW AY20 CO NC
DW AY20 CO NCFN20 1.8W OO DPALINGFN20 1.8W OO DPALINGSPHT00 SPHT00FN20 1.8W OO DPALINGFN20 1.8W OO DPALINGSPHT00 SPHT00FN20 1.8W OO DPALINGFN20 1.8W OO DPALING
SPHT00 SPHT00
FN20 1.8W OO DPALINGFN20 1.8W OO DPALING
SPHT00SPHT00FN20 1.8W OO DPALING
FN20 1.8W OO DPALINGSPHT00SPHT00SPHT00SPHT00SPHT00
SPHT00 SPHT00
SPHT00 SPHT00
TREENC00 5 2.5 0.25 JAC
TREENC00 8 2.5 0.35 NR
TREENC00 9 3.0 0.40 NRTREENC00 7 3.0 0.35 PAPR
TREENC00 7 3.0 0.35 NR TREENC00 5 1.5 0.15 NR
RO O F04
RO O F04RO O F04
RO O F05
RO O F05RO O F05
RO O F06RO O F06RO O F06
RO O F07
RO O F07
RO O F07RO O F07
BLDG 02 LSETRENDERED
G UTTER02
G UTTER02BLDG 02 LSETRENDERED
BLDG 02 LSETRENDERED
G UTTER02
FN20 1.8W OO DPALINGSPHT00
SPHT00FN20 1.8W OO DPALINGBW 08 1.0BLK
BW 08 1.0BLKSPHT00TREENC00 9 3.0 0.35 NR
TREENC00 7 2.5 0.30 NR
900
901
902
903
904 905
906906A
907 908
909 910
9111000
1001 1002 1003 1004 1005
10061007
1008
1009
101010111012
10131014
1015
1016101710181019
1020
10211022
102310241025
1026
10271028
10291030
10311032
10331034
10351036
103710381039
1040
10411042
10431044
104510461047104810491050105110521053105410551056
105710581059
106010611062
10631064 10651066
10671068
1069
107010711072
10731074
107510761077
10781079 10801081108210831084108510861087
10881089
1090
109110921093
1094
10951096
1097
10981099
11001101 110211031104
1105
1106110711081109
1110111111121113
111411151116
111711181119
1120112111221123
1124112511261127
112811291130
11311132
1133113411351136113711381139
1140
11411142
1143
1144 1145114611471148
11491150 11511152
11531154
1155
11561157
11581159
11601161
1162
11631164
1165
11661167
1168
11691170
11711172
117311741175117611771178
117911801181
1182
11831184118511861187
11881189
11901191
11921193
119411951196
1197
11981199
1200
1201
1202120312041205
1206
1207
12081209121012111212121312141215121612171218
1219122012211222
122312241225 1226
12271228
12291230 1231
1232
1233 1234
12351236
1237
1238
1239
1240
1241
1242124312441245124612471248124912501251125212531254 1255
12561257125812591260
12611262
12631264
12651266 1267126812691270
1271
1272127312741275
12761277
12781279128012811282 1283
1284
12851286128712881289
129012911292 12931294129512961297129812991300
13011302
1303
1304
13051306
1307
13081309
13101311
131213131314
1315131613171318
13191320132113221323 13241325
132613271328132913301331
1332133313341335 1336
13371338
1339
134013411342
13431344
1345
1346
1347 13481349
1350
1351
13521353
1354135513561357 1358
1359136013611362
13631364 1365
1366136713681369
13701371137213731374 1375
137613771378137913801381
138213831384 1385
1386138713881389
139013911392
139313941395139613971398
13991400
140114021403
1404140514061407140814091410141114121413
1414141514161417141814191420
14211422
1423
1424 14251426
14271428
1429
1430
14311432
1433143414351436
143714381439 1440
14411442
1443
144414451446
1447144814491450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
14611462146314641465 14661467146814691470
147114721473147414751476147714781479
1480
14811482
1483 14841485148614871488148914901491
149214931494
14951496149714981499
1500
1501
1502 1503150415051506150715081509151015111512151315141515
15161517
1518151915201521152215231524 1525
1526
15271528
1529
153015311532153315341535 15361537153815391540
15411542
15431544154515461547 154815491550
155115521553
15541555155615571558 1559
15601561
156215631564156515661567156815691570
157115721573
1574
157515761577
15781579 158015811582 158315841585
1586
15871588 1589
159015911592
159315941595
1596
1597159815991600
1601
1602 1603
16041605
16061607
1608
1609
16101611
1612
161316141615161616171618161916201621
16221623
1624 1625
16261627
16281629
1630
1631
163216331634
16351636 16371638 16391640 16411642 16431644 1645
1646 1647
1648 1649
16501651 1652
165316541655165616571658
1659 1660
1661 1662
1663
1664
16651666
1667 1668
1669
16701671
1672
167316741675
16761677
16781679
16801681
16821683
16841685
1686
1687
16881689
1690 16911692
169316941695
1696
SE
TB
AC
K
1500
SETBACK
1500
SETBACK
6000 POSSIBLE SEWER CHAMBER. CONFIRM LOCATION OF SEWER LINE AND ANY ASSOCIATED CHAMBERS. A CIVIL ENGINEERS ADVISE AND DESGN WILL BE REQUIRED.
300U
S
600U
S
600U
S
100U
S
100US
150US
150US
100U
S
G1
CL
BFC
FI
GS
fall
1:10
0
swal
e
swal
e
TURF
TURF
TURF
TURF
MRP
1:80 fall
49.200+
+49.990
+49.940+49.560 +49.450
swale
swale
CLBINS
20m
m
1:100 fall
1:50 fall
1:4
0 fa
ll1:
16
fall
1200 645 3000
1400
1200
3300
1250
1100
750
3000
1400
1:100 fall1:24 fall
1:22 fall
1:19 fall 1:20 fall 1:40 fallGR
AT
ED
DR
AIN
49.9
40+
190mm
1:100 fall
+49.245
49.100+
+49.080
1:2
0 fa
ll
+49.290
+49.240
+49.045
+48.935
+48.875
48.850+
+48.9
10
3600 1780
+49.9
10
+50.1
00
1200
1:40 fall
50.1
90+
+50.1
80
+50.1
20
+50.0
10
+50.0
70
+50.0
70
+49.9
70
+49.7
00
hwu hwu
BFC BFC
+49.1
20
+49.2
80
49.2
40+
+49.0
60
+49.0
30
49.0
70+
+48.9
70
49.2
20+
+49.2
80
+49.2
20
+49.2
00
+49.1
70
50.1
80+
PATH BFC
LB GB
GB
GB
GB
GB GB
GB
GB
dp
dp
dp
dp
FI
FI
FI
MB
+50.2
50
SC
R
2 BED UNIT 1
GOLD / FFL 50.200
1:100 fall
1 BED UNIT 2
GOLD / FFL 49.300
1:100 fallBFC
GB
BFC
G1GS
+49.2
00
500
G1
1:7 fall
feature tree1:33 fall
1:36 fall
1:20
1200
BINS
dp
dp
dp
+49.7
50
4500
+50.1
70
+50.1
30
LB
MAKE GOOD (FOOTPATH) TURF, CROSSOVER, KERB & CHANNEL TO
COUNCIL REQUIREMENTS FOR CONTINUATION OF CROSSOVER REFER TO SITE SETOUT PLAN A01.02
BFC
BFC
30.570m 90°21"0"
26.547m 90°21"0"
20.1
17m
50.1
00+
0°11
'0"
16.0
94m
180°
11'0
"
5.698m
315°76'0"
GR
AT
ED
D
RA
IN
SCR
GB
1200 high tubular fence 1200 high tubular fence
1200
hig
h tu
bula
r fe
nce
1200
hig
h tu
bula
r fe
nce
1200 - 1800 raking timber paling fence 1800 timber paling fence 1800 timber paling fence
1800
tim
ber
palin
g fe
nce
1200
-18
00 r
akin
g tim
ber
palin
g fe
nce
1800
tim
ber
palin
g fe
nce
1:50 fall
1:2
5 fa
ll
50.3
40+
1228
+50.0
70
+50.3
00
4982
+49.270
+49.210
1:40 fall
190m
m
190m
m
TOWN PLANNING:YIELD: 1 x 1 & 1 x 2 BEDROOM DUPLEXMAX HEIGHT ALLOWED: 2 STOREY AND 9.5mACTUAL: 4.2m (approx)
AREA CALCULATIONSUNITS (incl. PATIOS, STAIRS & EAVES - 255.04m²
SITE AREA 607.00 m²
MAX. SITE COVER (50%) 303.50m²
AREA CALCULATED 255.04m²
SITE COVER (ACTUAL) 42.02%GARDEN BEDGB
LEGEND:
TURF
BFC
BFC
+29.950
ADJACENT SURFACES FLUSHTURFING
CONCRETE DRIVEWAY
CONCRETE PATH
BUILDING EXTENTS
LB LETTER BOX
FINISHED SURFACE LEVEL
RETAINING WALL
DP DOWNPIPE
G1 1800mm TIMBER PALING GATE
BOK BOTTOM OF KERBBOW BOTTOM OF WALLCL CLOTHES LINE
PP POWER POLEFI FIELD INLET
GB GARDEN BEDGS GARDEN SHEDMB METERBOARD
RW RETAINING WALLUS UPSTANDSCR METAL SCREEN
- REQUIRED PLANNING SETBACKS SHOWN INDRAWINGS ARE INDICATIVE SKETCH FOR REFERENCE ONLY.- CONTRACTOR/CONSULTANT TO VERIFY SITE CONDITIONS SHOWN ON THE
VDRAWING WITH CONTOUR & DETAIL SURVEY & ACTUAL SITE CONDITIONS.- PARTY WALLS & SLABS: VERIFY DETAIL TO ACHIEVE ACOUSTIC RATING TO COMPLY WITH NCC. ADJUST O/A BUILDING WIDTH & HEIGHT ACCORDINGLY.- ALL EXPOSED SERVICES & PIPEWORK TO BE CONCEALED PUBLIC VIEW (EG. IN SUITABLE DUCTS/SCREENS. ETC.)- PROPOSED STRUCTURE DOES NOT IMPACT THE EXISTING SEWER.
FLOOD HAZARD MANAGEMENT IS TO BE DESIGNED BY CIVIL ENGINEERS AS REQUIRED.
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
As indicated
85271 SD A01.03 4D
EXTERNAL WORKS PLAN
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
SCALE 1 : 100
EXTERNAL WORKS PLAN1
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
A 08.03.19
REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
OUTDOOR SPACES INCREASED
B 27.03.19 BED 2 BATHRM ALTERED
C 01.04.19 HARDSTAND REPLACES TURF NORTH SIDE OF UNITS
D 05.06.19
BED 2
LIVING
BATH
KITCHEN
PATIO
DINING
wc
cpt
vinyl
vinyl
ct
MSB
pan
10m
m
hwu
2450
9024
6090
1000
9060
2590
1200
90 6025 90 3560 205 4165 90600 3085 90
1005 1520 1000
2050
1040
1000
1520
1004
1005
1735 4140 4095 8030
grat
ed d
rain
300
9032
3090
2365
9019
3590
3050
9024
50
300
1200
12001065
90 3450 60090 3800 205 2200 90 2330 90 3230 90
14225 3775
2450
9845
3410
2365
5255
2450
9080
0090
3025
9010
00
1335
9016
0090
900 90 1440 90 102090
600 1350 90
grat
ed d
rain
KITCHENvinyl
LIVINGvinyl
DINING
L'D
RY
L'DRY
ltwmdr
wmdr
lt
linen
linen
b
shr
shr
wc
BATHct
11.01m²
9018
4090
1120
9022
7490
800
1226
90
pan
wo
wo
hp
hp
s
s
cupb
dcu
pbd
cupb
dcu
pbd
d
d
ls
lsref
ref
vb
vb
11.08m²
11.39m²
BED 1cpt
BED 1cpt
roberobe
robe
10mm
20m
m
20mm
GARAGE
GARAGE
bfc
bfc
hwufloor area of patio shown in m²
12.960m²
PATIO
14.110m²
18000
1348
0
floor area of bedrooms shown in m²
2 BED: GOLD
UNIT 1
1 BED: GOLD
UNIT 2
roof line over
roof
line
ove
r
roof line over
roof
line
ove
r
1672 3410
3410
2349
1209ss 1209ss 1212ss 1212ss
2121
sd
20mm
0618ss
1218
ss
2121sd920sd
2A02.02
2A02.02
2127
rd
2127rd
beam over
beam
ove
r
920
920
2121
sd0906ss
0906
ss
0906ss0909ss
1221ssdp
1212
ss
1212ss
920
brm
920
PORCH
PO
RC
H
dp
dp
dp
dp
brm
920
920
sd
desk
cf
cf
cf
cf
1000
1134
DB
privacy screen
privacy screen
priv
acy
scre
en
awni
ng/s
cree
n
awning/screen
cf
300
300
3000 90 1530 90
3000
3000
4320
skl
skl
540
480x
2
fall
fall
20mm
cr
cr
100010
00
1000
cf
cf
dp
awning/screen awning/screen awning/screen
dp
NBN
NBN
FLOOR SLAB SETDOWNS:
BATHROOM, LAUNDRY & WC - 100mm
PROVIDE WATERPROOFING TO ALL WET
ZONES IN ACCORDANCE WITH NCC.
HARDWIRED SMOKE DETECTOR
(as per new 2018 regulations)
sd
LEGEND
b BATH
bfc BROOM FINISH CONCRETE
brm BROOM CUPBOARD
cf CEILING FAN
cl CLOTHES LINE (OPTIONAL LOCATIONS)
cpt CARPET
ct CERAMIC TILES
DB DISTRIBUTION BOARD
cr CURTAIN RAIL (shr)
d DRAWERS
dp DOWN PIPE
dr DRYER (NIC)
hp HOT PLATES
hwu HOT WATER UNIT
lin LINEN CUPBOARD
ls LAZY SUSAN
lt LAUNDRY TUB
msb ELECTRICAL MAIN SWITCHBOARD
pan PANTRY
ref REFRIGERATOR
s SINK
SS SECURITY SCREEN TO WINDOW
shr SHOWER
shl SHELF
skl SKYLIGHT
v VINYL
vb VANITY BASIN
wm WASHING MACHINE (NIC)
wc TOILET SUITE WITH CISTERN
wo WALL OVEN
NBNNATIONAL BROADBAND NETWORK
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
As indicated
85271 SD A02.01
FLOOR PLAN
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
SCALE 1 : 100
PROPOSED FLOOR PLAN1
BUILDING AREA - UNIT 1
UNIT GFAGARAGEPATIO
ENTRY PORCH
TOTAL
= 82.59m²= 20.85m²
= 14.12m²= 3.41m²
=120.97m²
BUILDING AREA - UNIT 2
UNIT GFAGARAGEPATIO
ENTRY PORCH
TOTAL
= 64.29m²= 20.85m²
= 12.96m²= 2.62m²
= 100.72m²
BH
TBC
FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
A 06.03.19 OUTDOOR SPACE INCREASE
D
B 27.03.19 ACCESS TO BATHRM CHANGED, L'DRY MOVED
C 01.04.19 LINEN CUPBD DOOR, NEW SKYLIGHTS, SHR CR
D 05.06.19 REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
5
2A02.02
2A02.02
FALL8
FALL
8
FALL
8
FALL8
dp
dp
dp
dp
dp
dp
dp
MR
C
MHC
MBCMHC
MBC
MHCMHC
MEG
ME
G
MEG
ME
G
MEG
ME
G
ME
G
MRS
MRS
MRS
MRS
SKL
SKL
FLASHING
2700
900
2700
UNIT 1
UNIT 2
GARAGEKITCHEN/LIVING/DINING
KITCHEN/LIVING/DINING
BATHROOM
WALLS TO UNDERSIDE ROOF (FOR ACOUSTIC & FRL PROPERITES)
AG PIPE
DOWNPIPE
METAL BARGE CAPPING
METAL EAVES GUTTER
METAL HIP CAPPING
METAL RIDGE CAPPING
COLORBOND
METAL VALLEY GUTTER
ROOF VENT (PASSIVE)
VENTED SKYLIGHT AS SPECIFIED
SPREADER
DIRECTION OF GUTTER FALL
TO DOWNPIPE
DP
MBC
MEG
MHC
MRC
MRS
MVG
MRV
SKL
SPR
ROOF
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
1 : 100
85271 SD A02.02
ROOF PLAN & SECTION
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
SCALE 1 : 100
ROOF PLAN1
SCALE 1 : 100
SECTION 12
BH FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
B 27.03.19 ACCESS TO BATHRM CHANGED, L'DRY MOVED
D
C 01.04.19 LINEN CUPBD DOOR, NEW SKYLIGHTS, SHR CR
D 05.06.19 REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
6
2700
900
2700
1209ss1221ss
0909ss 0906ss
920 2127rdprivacy screen
privacy screen
skl
skl
top
of s
cree
n
1800
top
of s
cree
n
1800
fence
2700 1218ss 2121sd2121sd
hwu
awning
skl
top
of s
cree
n
1800
privacy screen
skl
2700
2700
900
1212ss 1212ss
1209ss 1209ss
hwu
hwu
0618ss
2121sdawning awning
awning awning
skl
skl
top
of s
cree
n
1800
top
of s
cree
n
1800
privacy screenprivacy screen
privacy screenprivacy screen
dpdp dp
dp
fence
2700
2127rd 920
0906ss 1212ss
2121sd
hwu
privacy screento
p of
scr
een
1800
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
1 : 100
85271 SD A04.01
ELEVATIONS
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
SCALE 1 : 100
SOUTH ELEVATION1
SCALE 1 : 100
EAST ELEVATION2
SCALE 1 : 100
NORTH ELEVATION3
SCALE 1 : 100
WEST ELEVATION4
ROOF SHEETING:
COLORBOND
ROOF PITCH: 8°
HWU: HEAT PUMP
WALL SHEETING:
PREFINISHED
LINEA OR SIMILAR
WALL SHEETING:
PREFINISHED
LINEA OR SIMILAR
WALL SHEETING:
PREFINISHED
LINEA OR SIMILAR
ROOF SHEETING:
COLORBOND
ROOF PITCH: 8°
ROOF SHEETING:
COLORBOND
ROOF PITCH: 8°
WALL SHEETING:
PREFINISHED
LINEA OR SIMILAR
ROOF SHEETING:
COLORBOND
ROOF PITCH: 8°
WALL SHEETING:
THERMAL INSULATED
CLADDING RENDERED
AND PAINTED
WALL SHEETING:
PREFINISHED
LINEA OR SIMILAR
BH FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
C 01.04.19 LINEN CUPBD DOOR, NEW SKYLIGHTS, SHR CR
D
D 05.06.19 REMOVE BATH & PORCH ROOF UNIT 2 ADD SCREENS
7
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
85271 SD A04.02
3D VIEWS
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
SCALE
3D View 11
SCALE
3D View 22
NO GROUND LINES SHOWN
NO GROUND LINES SHOWN
BH FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
D 8
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
85271 SD A04.03
STREET VIEWS
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
BH FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
D 9
DRAWING NUMBER
MASTER SITE NUMBER
SCALE
ISSUE
CLIENT REFERENCE NUMBER
SHEET NO
AT
A3 SIZE
Housing and Public WorksDepartment of
AUTHORISED FOR ISSUE DATE
DATE
DATE
MASTER PLAN
HYDRAULICS
FURNITURE & EQUIPMENT
FLOOR PLANS
FITOUTS
EXTERNAL WORKS
ELEVATIONS
CONSTRUCTION DETAILS
CEILING PLANS
STANDARDS
SITE PLAN
SETOUT PLAN
SECTIONS
ROOF PLANS
PLAY STRUCTURES
OTHER
MISCELLANEOUS DETAILS
FOR BUILDING and ASSET SERVICES ONLY
DRAWING INDEX SYSTEM
ISSUE DATE SUBJECT AUTHORISED
AMENDMENTS
PARISH COUNTY
LOCAL AUTHORITY
SITE AREA LOT(S)
DISCIPLINE TEAM LEADER
DRAWN
050
100
150
200
250
300
350
400
450
500
85271 SD A05.01
PARTY WALL INFO.
10 LYNTON STREET
UPPER MNT GRAVATT
HCJP PROGRAM:CBRC (HCJP)1x1 & 1x2 BEDROOM DUPLEXSCHEMATIC DESIGNGOLD LEVEL
BH FEB 2019
RB FEB 2019
AG FEB 2019
BULIMBA STANLEY
BRISBANE CITY COUNCIL
607m² LOT 99 ON RP 86160
55989
D 10