1
Your Curtis Gemini is Factory Pre-Set and Ready to Go… Right from the Box.Following are the Factory Settings for your interLock Coffee Brewing Systems: •BrewTemperature=200°F •WaterBypass=OnLARGE&MEDIUMbrewonly •BrewVolume=Largesettovesselrequirements. •EnergySaveMode=OffSystemRequirements: •WaterSource20–90PSI(MinimumFlowRateof1GPM) •Electrical:Seeattachedschematicforstandardmodelorvisitwww.wilburcurtis.comforyourmodel.SETUPSTEPSTheunitshouldbelocatedonasolidcountertopandleveled(lefttorightandfronttoback),.Connectawaterlinefromthewaterfiltertothebrewer.
NOTE:Awaterfiltrationsystemmustbeinstalledtomaintainatrouble-freeoperation.(Inareaswithextremelyhardwater,wesuggestthatasedimentaryandtaste&odorfilterbeinstalled.)Thiswillprolongthelifeofyourbrewingsystemandenhancecoffeequality.
Conventions
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
1.A3/8”Flarex3/8”Malepipeelbowissuppliedwiththebrewerforwaterlineconnection.Usetubingsizedsufficientlytoprovidea minimumof1.0GPM.2.Connecttheunittoanappropriateelectricalpowercircuit.3.Turnonthetoggle(STANDBY/ON)switchbehindtheunit.Theheatingtankwillstarttofill.Whenthewaterlevelinthetankrisestothe correctvolume,theheatingelementswillenergizeautomatically.WithADSSystemsthereisnodangerofelementburnoutcausedby anemptytank.4.Theheatingtankwillrequire20to30minutestoreachoperatingtemperature(200°F),indicatedwhenREADYTOBREWisdisplayed ontheLCDscreen.5.Priortobrewing,dispense12ouncesofhotwaterthroughthehotwaterfaucet.6. Brewacycleofatleast12ounces,topurgethewaterlinesofanyairthatmaybetrappedafterfilling.
Models GEMTS GEMSS
CAUTION: DO NOT connect this brewer to hot water. The inlet valve is
not rated for hot water.
CAUTION: Please use this setup procedure before attempting to use
this brewer. Failure to follow the instructions can result in injury or the voiding of the warranty.
WARNING: TO AVOID SCALDING, Do not remove brewcone while brew light is flashing.
WARNING HOT LIQUID, Scalding may occur. Avoid splashing.
IMPORTANT: Equipment to be installed to comply with applicable federal,
state, or local plumbing/electrical codes having jurisdiction.
BREWINGINSTRUCTIONS 1.BrewershouldbeON(Confirmatreartoggleswitch,thenpresstheON/OFFbutton).Ready-to-Brewshouldbeonthedisplay.Ifthe brewerisconnectedtoanInterLockgrinder,thegrindershouldbeon.WhenInterlockconnectionismade,grindcoffeeatthistime. 2.PlaceanemptySatelliteunderthebrewconeandpressthewarmerswitchtopre-heattheSatellite.
6. PressBrewbutton.Brewing willbeginimmediately.
5. Transferfilledbrew conetobrewer.
3.Placeacleanfilter intothebrewcone.
4.Fillbrewconewith ground coffee.
C
NSF International requires the following water connection:1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for clean-
ing underneath the unit.2. This equipment is to be installed with adequate back flow protection to comply with applicable federal, state and local codes.3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in
accordance with federal, state, and local codes.
ISO9001:2008WilburCurtisCompanyMontebello,CA90640Tel:(323)837-2300www.wilburcurtis.com
ImportantSafeguards/ConventionsThisapplianceisdesignedforcommercialuse.AnyservicingotherthancleaningandpreventivemaintenanceshouldbeperformedbyanauthorizedWilburCurtisservicetechnician. •DONOTimmersetheunitinwateroranyotherliquid •Toreducetheriskoffireorelectricshock,DONOTopenservicepanels.Nouserserviceableparts
inside. •Keephandsandotheritemsawayfromhotsurfacesofunitduringoperation. •Nevercleanwithscouringpowders,bleachorharshchemicals.
Wilbur Curtis Company, inC.ServiceManual–GEMTS/SS
2
Curtis
CurtisReady
EnteringProgramming Mode
Enter Code- - - -
Program Menus<-- Select -->
Global Recipes<-- Select -->
Gourmet STD<-- Select -->
Light Roast<-- Select -->
Dark Roast<-- Select -->
High Yield<-- Select -->
Filter Pack<-- Select -->
Decaf<-- Select -->
Exit<-- Select -->
Non-Brew Prog<-- Select -->
Temperature<-- Select -->
Energy Save Mode <-- Select -->
Brew Count Odom<-- Select -->
Quality Timer<-- Select -->
Brew Count Total<-- Select -->
Cold Brew Lock<-- Select -->
Master Reset<-- Select -->
Service Call<-- Select -->
Acess Code<-- Select -->
Banner Name<-- Select -->
P-Maintenance<-- Select -->
Beeper On/Off<-- Select -->
Drip-Out Mode<-- Select -->
Warmers Default<-- Select -->
Exit<-- Select -->
Brew Button Prog<-- Select -->
Select Button…<-- Select -->
Brew By Volume <-- Select -->
Brew By Time<-- Select -->
Pre-Infusion<-- Select -->
Pulse Brew On/Off<-- Select -->
Bypass On/Off<-- Select -->
Exit<-- Select -->
One Batch<-- Select -->
Two Batch<-- Select -->
Three Batch<-- Select -->
Exit<-- Select -->
Model Select<-- Select -->
ThermoPro Twin<-- Select -->
ThermoPro Single<-- Select -->
Gemini - Single<-- Select -->
Gemini - Twin<-- Select -->
Milano Twin<-- Select -->
Milano Single<-- Select -->
Gemini - Twin IF<-- Select -->
Gemini - Single IF<-- Select -->
Display Brew Time<-- Select -->
Warmers Auto-Off<-- Select -->
YourCurtisADSSystemisFactoryPre-SetforOptimumPerformance.Afterconnectiontowaterandpower;thereartoggleswitchmustbeon.Youwillhearabeepsound,indicatingpowerisavailabletothecontroller.
Thecontroldisplays .PressON/OFFbuttonandthescreenwilldisplay .Afterthreeseconds, isdisplayed.
Waterwillfillthetank(approximately2-3minutesdependingonwaterflowrate).Whentheproperlevelisreached willappearonthescreen.Ittakesapproximately20minutestoreachsetpointtemperatureof200°F.
Controlwilldisplay whentemperaturereachesthesetpoint(200°F).Unitisnowreadytobrew.
<GEMINITWIN>WILBURCURTIS
CURTIS CURTISFILLING
CURTISHEATING
CURTISREADYTOBREW
PROGRAM MENUS
All programming selections are performed with the three center buttons. The symbols below the buttons are:
Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT
IMPORTANT NOTE:
3
Program Menus GEMTS/SS Brewer
Program Menus
Temperature
Energy Save Mode
Brew Count Odom
Global Recipes
Banner Name
Access Code
Service Call
Master Reset
Cold Brew Lock
Brew Count Total
From Program Menus press>displaywillshowthenextfeatureGlobalRecipes.
Quality Timer
NON-BREW PROGRAMMINGTemperature(Factorysetto200ºF)Press toSelect.Press<or>tomovetodesiredtemperatureandthentoset.Temperatureisprogrammablefrom170ºFto206ºFin2-degreeincrements.
Energy Save Mode (FactorysettoOFF) Press toSelect,<or>ON,OFForON140ºF,toset.WheninON,unitwillautomaticallyshutoff4hoursfromlastbrew.WhenfeatureisOFF,unitdoesnotutilizetheenergysavingmode.IntheON140ºFposition,temperaturelowersto140ºF,ifunithasnotbrewedin4hours.Thisfeaturewillsaveenergybymaintainingalowertemperatureinthetankinperiodsofnon-operation.
Brew Count OdomPress todisplaytotalbrewcycles.PressEXorReset.
Quality Timer (FactorysettoOFF)Press to select,press<or>tochoosedesiredsetting.Range20min–240min,in10minuteincrements.Thetimerdoestwothings.Itturnsonandoffaredindicatorlightandturnsoffthewarmerelement.Theindicatorlightsignalswhenapredeterminedtimehasexpired.Thewarmershutsoff12hoursaftertheindicatorlightcomeson.
Brew Count Total Press toSelect,Showstotalgallonsandtotalbrewcyclesontheunit.Notresettable.
Cold Brew Lock ...(Factorysetto5º)Press toselect,<or>toselectdesiredsetting(CBL5,15orOFF), to set.TheColdBrewLockfeatureallowsthebrewertobrewatthreedifferenttemperaturelevelsfromtheactualsetpoint.Thefirstsettingiswithin5degreesofsetpoint,nextiswithin15degreesofsetpoint,OFFiswithin30degreesofsetpointfortheReadytoBrewmessage,however,itwillbrewatanytemperature.
Master Reset Press todisplayAreYouSure?Then<forYes,>forNo.Brewerfactorydefaultsarethenreset.
Service Call (PhonenumberFactorysetto1-800-000-0000X0000)Press todisplaynumberandchangenumberor<tomoveplaceandEXtoexitwhencomplete.ThisnumberwillbedisplayedduringaHeatingsystemSENSORERRORorduringaWATERERROR.
Access Code(Factorysetto1-2-3-4)Press todisplaynumberandchangenumber,(thenumbercanbechanged1to4)or<tomoveplaceandEXtoexitwhencomplete.
Banner Name(FactorysettoCURTIS)Press todisplaylettersandchangelettersor<tomoveplaceandEXtoexitwhencompleteThisfeatureallowsupto14letterstobeprogrammedforcompanynameorregionalname.Programmingallblanksdis-ablesBannerName.Ifprogrammed,BannerNameisdisplayedevery5sec.onandoff.
Warmers Auto – Off(Factorysetting–Disabled)Press toSelect.Press<or>toadjustfrom1hourto12hours.Thisfeatureadvancesin1hourincrements.
GLOBAL RECIPESGlobal Recipes(FactorysettoGourmetSTD)Press toselect.Ifselected,press<or>tochosearecipebasedonthetypeofcoffeebeingbrewed.SelectionsareGourmetSTD,LightRoast,DarkRoast,HighYield,FilterPack,orDecaf.Press toselectthedesiredrecipe.
Warmers Auto-Off
4
Program Menus GEMTS/SS Brewer
P-Maintenance
Brew By Time
Brew By Volume
Displ. Brew Time
Pre-infusion
Pulse Brew
By-Pass
Model Select
P-Maintenance(FactorysettoOFF)Press toSelect,SetgallonsbrewedtoindicateP-Maintenance.Press<or>toadjustfromOffto9500gallons.Thisfeatureadvancesin100gallonincrements.Press to exit.
Beeper On/Off (FactorysettoON)Press todisplayONorOFF.Pressingeither<or>togglesbetweenonandoff.toset.WhenON,thisfeatureallowsyoutohearashortbeepeachtimeabuttonispressed.
Drip-out Mode (Factorysetto2minutes)Press toSelect.Press<or>tomovetodesiredtime.SettingsareOFF,1,2,3,4and5minutes.Press to Select time.
Warmers Default(Factorysetting-MED)Press toSelect.Press<or>toadjustfromOFF,HIGH,MEDorLOW.PowersettingforHIGHis100WwattsMEDis82watts.LOWis66watts.
Displ. Brew Time (FactorysettoON)Press todisplayONorOFF.Pressingeither<or>togglesbetweenonandoff.AfterDisplayBrewTimeanEXITscreenwill return you to Non-Brew Prog.
Drip-out Mode
Beeper On/Off
Warmers Default
BREW BUTTON PROGRAMMINGBrew by Volume(Factorysettings:LARGE200oz±8oz.MEDIUM132oz±4oz.SMALL64oz±4oz.)Press toSelect.Displaywillaskyoutoselectabrewbutton,Large,MediumorSmall.Pressthedesiredbrewbuttontobegin...whendesiredvolumeisreachedpressthesamebrewbuttontostoptheflow.Nowthevolumehasbeenset.
Brew by Time(Factorysettings:LARGE5min-25sec.MEDIUM3min-32sec.SMALL1min-52sec.)NextiteminthesequenceisBrewbyTime.PresstoSelecttochangethebrewtime.Displaywillnowshowthecurrenttime.Bypressing<or>youcantogglebackandforthfromminutestosecondstoexit(ex).Changethetimeorsetandexitbypressingthebutton.
Pre-Infusion(FactoryDisabled)Press toSelect.Currentsettinginsecondsisdisplayed<todecreaseorselect>toincrease(rangefromOFFto10through60seconds), to set. IfPre-infusionisselected(ON),ColdBrewLockissetwithin5ºFofsetpointandColdBrewLockdisappearsfromthelistofprogramselections.WhenPre-infusionisON,PulseBrewdisappearsfromthelistofprogramselections.
Pulse Brew(FactorysettingC)Press toselect,<or>toselectOFForoneoffivepulsepatterns(AtoE).ThefivePulseBrewoptionshelp“tune”orchangethecoffeeflavor.Guidelines for Pulse Brew:FilterPacktypecoffeestypicallyextractbetterwiththeA and Bpulsesetting.DecafcoffeestypicallyextractbetterwiththeBpulsesetting.High-YieldcoffeestypicallyextractbetterwiththeCpulsesetting.Ofcourse,anyoftheA, B or Csettingsmaybeusedtosuityourtasteprofile.Settings D and Earemanualpulsecounts.ToexitfromthePulseBrewmode,select0 for the time.IfPulseBrewison,ColdBrewLockissetwithin5ºFofsetpointandColdBrewLockdisappearsfromthelistofprogramselections.WhenPulseBrewison,Pre-infusiondisappearsfromthelistofprogramselections.
By-Pass (Factorysettings:LARGE35%.MEDIUM10%.SMALLOff.)TheBy-Passoptionhelpswithcontrollingextractionwithlargerbrews.Contacttimethatistoolongwillextractundesirablebitter,harshflavorcompounds.By-passingsomeofthebrewwateraroundthecoffeebedwillbalancetheextraction.Press todisplaycurrentsetting.Press<or>tochangesettings;OFF,5%to50%,in5%increments.Press to set.
Model Select(FactorysettoGemini-TwinIF)Press toselect,<or>toselectmodel.Theselectionsare:ThermoPro-Twin,ThermoPro-Single,Gemini-Twin,Gemini-Single,Milano-Twin,Milano-Single,Gemini-TwinIF,andGemini-SingleIF.Presstoset.WhentheModelSelectfeatureischanged,allsettingsareresettothedefaultsofthenewlyselectedmodel.
5
ERROR MESSAGE DESCRIPTION CAUSE
(900) 000-0000 EXT (0000)Water Level ERR.
Fill run error/Overflow The fill solenoid has either run formore than 10 minutes on the initialtank fill or 1 minute, 30 seconds in normal operation.
Break in the temperature thermistorcircuit.
Open Probe(900) 000-0000 EXT (0000)Sensor Error
(900) 000-0000 EXT (0000)Over Temp. Error
Excess Temperature The sensor is reading the tempera-ture in the heating tank has risen above 210ºF.
1-(800)-000-0000Water Level Error
1-(800)-000-0000Sensor Error
1-(800)-000-0000Over Temp. Error
Error MessageAnerrormessagewillappearonthescreenintheeventofamalfunctionunderthefollowingconditions:
1.WaterLevelOverflow.
2.BreakinTemperatureControl Circuit
3.ExcessTemperatureinHeatingTank
Toturnoffanerrormessage,pressthebuttonforfiveseconds.
WarmersThewarmer,underthebrewconewillturnonautomaticallywheneveracoffeebrewcycleisstarted.ThewarmersmaybeswitchedonandoffusingtheWARMERbuttonsonthecontrolpanel.
CLEANING
Regularcleaningofyourcoffeebrewerwillmaintainthehighestqualitycoffeeyourequipmentiscapableofproducing.Apropercleaningisessentialinpreservingtheappearanceofthebrewer.
1. Turnofftheunitatthebuttononthefrontcontrolpanel.
2. Wipeexteriorsurfaceswithadampcloth,removingspillsanddebris.
3. Slidethebrewconeoutandcleanit.Thoroughlysoapthesprayheadareawithamilddetergentsolution.
4. Washthebrewbasket.Useasoftbristledbrushforhardtocleanareas.Washbothpartswithadetergentsolutionorputthesepartsthrough a dishwasher.
CAUTION: DO NOT use undiluted bleach or chlorine.
LEFT & RIGHTSATELLITE WARMERS
6
19
567
22
29
21
202
32
31
A
89
10
1112
13
14
15
16
17
18
24
12
3
4
PARTS DIAGRAMSGEMTS
11A23 4 5 66A 6B 6C7891011121314151617181920212222A23242525A262728293031323334
WC-3357WC-3354WC-5421WC-844-101*WC-37121*WC-441WC-39395WC-39440WC-39439WC-39438WC-37176*WC-8559WC-1809*WC-5423WC-847*WC-2977-101WC-37122*WC-442WC-29050WC-1501WC-102*WC-3765L*WC-39462WC-37102*WC-3528*WC-61393WC-5829WC-54287WC-37008*WC-37278WC-5502-01*WC-5350WC-4382WC-934-04*WC-1438-101*WC-43055WC-522*WC-5231*WC-62033WC-2402
BREWCONEW/HANDLEBREWCONE,GOURMETLRGCAPCOVER,TOPKIT,VALVEBY-PASSNON-ADJUSTKIT,DUMPVALVELEFTSOLENOID,LOCKBREWCONELEFTLABEL,UCMOVERLAYDUALTWINLABEL,CONTLPANEL3BATCHLABEL,CONTLPANEL2BATCHLABEL,CONTLPANEL1BATCHKIT,UCMCONTROLMODULERELAY,SOLIDSTATE40AW/HTSNKFAUCET,HOTWATERDECKASSYNOHEATINGELMTSVALVE,INLETFITTING,SPRAYHEADULTEMKIT,DUMPVALVERIGHTSOLENOID,LOCKBREWCONERIGHTSPRAYHEAD,AFS-AMBERFUSEHOLDERASSYW5AFUSESWITCH,TOGGLEKIT,VALVEREPAIRLABEL,BOTTOMPANELGEMTSKIT,WARMERELEMENTLEG,4”ADJUST3/8-16THRDITALIANCOVER,FRONTW/AGEMTSTALLCOVER,FRONT(5/2010ANDEARLIER)TANK,ASSYTPS1T/GEMTSKIT,TANKLIDROUNDKIT,LIQUIDLEVELPROBEGTPROBEASSY,WTRLVL(OLDERUNITS)TUBE,½”IDx1/8WSILICONEGUARD,SHOCKHEATINGELEMENTELEMENTHEATING2.5KW220VSENSOR,HEATINGTANKGUARD,SHOCKRESETT-STATTHERMOSTAT,RESETCOMPOUND,SILICONETANK,CMPLTGEMTSW/ULTEMFTNGELBOW,3/8”FLx3/8”M.PIPE
Nº Part Nº Description
Nº Part Nº Description11A233A3B 4 5 66A78910111213141516171819202122232424A2525A26272828A29303132
WC-58117WC-5450WC-37122*WC-39436WC-39432WC-39434WC-3357WC-29050*WC-61396WC-5452WC-8559*WC-39448WC-1809*WC-847*WC-2402WC-37130*WC-1501WC-102*WC-3528WC-5451WC-38310WC-37102*WC-3765L*WC-37132*WC-2977-101WC-37176*WC-5853-102WC-62035WC-62034WC-37278WC-5502-01*WC-522*WC-43055WC-906-04*WC-904-04WC-5350WC-43801WC-1438-101*WC-5231*
COVER,TOPCOVER,TOP(OLDERUNITS)KIT,DUMPVALVERIGHTLABEL,CONTROLPANEL3BATCHLABEL,CONTROLPANEL1BATCHLABEL,CONTROLPANEL2BATCHBREWCONEASSYCOMPLETESPRAYHEAD,AFS-AMBERCOVER,FRONTGEMSSTALLCOVER,FRONT(5/2010ANDEARLIER)RELAY,SOLIDSTW/INTGRTDHTSNKLABEL,BOTTOMWRAPGEMSSFAUCET,HOTWATERVALVE,INLET2GPM120V10WELBOW,3/8”FLx3/8”M.PIPEKIT,VALVEBYPASSFUSEHOLDERASSYW/5AFUSESWITCH,TOGGLE125V,80ALEG,4”ADJUST3/8-16THRDITALWARMERDECK-NOHTGELMTSLABEL,CAUTIONHOTSURFACEWARMERELEMENTKIT,VALVEREPAIRKIT,VALVEREPAIRFITTING,SPRAYHEADULTEMKIT,UCM&LABELINSTRUCTIONSCOVER,TOPHEATINGTANKGENUSETANK,COMPLETEGEMSSW/ULTEMTANK,COMPLETEGEMSSDVULTEMKIT,LIQUIDLEVELPROBEGTPROBEASSY,WTRLVL(OLDERUNITS)THERMOSTAT,RESETSHOCKGUARD,RESETTHERMOSTATHEATINGELEMENT,2000W220VELEMENT,HEATING1.6KW120VTUBE,½”IDx1/8WSILICONESHOCKGUARD,HEATINGELEMENTSSENSOR,TEMPHEATINGTANKCOMPOUND,SILICONE3/4OZTUBE
GEMSS
*Recommmendedpartstostock.
*Recommmendedpartstostock.
11A
234
567
89
10
11
121314151617
18
262728293031
32
192021
22
33
34232425
7
ELECTRICALSCHEMATIC–GEMTS
8
ELECTRICALSCHEMATIC–GEMSS
9
1 1A 2 3 4 5 6 7 7A 8 9101112131415
WC-5622WC-3307WC-2102WC-2005*WC-2010CWC-2025*WC-2006*WC-1800WC-1841WC-3705*WC-1901AWC-37102WC-3503WC- 114RGEM-3GEM-5GEM-8
LID, SATELLITE PLASTIC GEM3LID, SATELLITE STAINLESS (OLDER UNITS)GAUGE GLASS ASSEMBLY 8”WASHER, SHIELD CAP 1/8”SHIELD, 8 INCH GAUGE GLASSGAUGE GLASS, 8 INCHWASHER, SHIELD BASE 3/16”FAUCET, S’ NON LOCKINGFAUCET, ESP BLACK NON-LOCKING PLASTICKIT, FAUCET S’ SERIESSHANK, FAUCET W/SHIELD BASEKIT, WARMER ELEMENT 100W 120VLEG, SCREW BUMPER 3/8”– 16 STDSWITCH, ROCKER (RED) 120V NEON SPST 15A 250VSATELLITE SERVER 1/2 GALLONSATELLITE WARMER STAND 120V 100W 1A 1PH 2W+GSATELLITE WARMER STAND, SHORT 120V 100W
Nº Part Nº Description
* Suggested parts to stock for servicing.
4
2
1
3
6
5
87
9
10
1112
14
15
13
PARTS DIAGRAMSGEM-3, SATELLITE COFFEE SERVERGEM-5, SATELLITE WARMERGEM-8, SATELLITE WARMER SHORT
10 ECN 12835 . 12/28/10 @ 9.5 Printed in U.S.A. 12/10 . F-3373-S . rev F
WILBUR CURTIS CO., INC.6913AccoSt.,Montebello,CA90640-5403USAPhone:800/421-6150 Fax:323-837-2410 TechnicalSupportPhone:800/995-0417(M-F5:30A-4:00PPST) E-Mail:[email protected] WebSite:www.wilburcurtis.com
Product Warranty InformationThe Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply:
3 Years, Parts and Labor, from Original Date of Purchase on digital control boards.2 Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing.
1 Year, Labor, from Original Date of Purchase on all electrical components, fittings and tubing.
Additionally, the Wilbur Curtis Company warrants its Grinding Burrs for Forty (40) months from date of purchase or 40,000 pounds of coffee, whichever comes first. Stainless Steel components are warranted for two (2) years from date of purchase against leaking or pitting and replace-ment parts are warranted for ninety (90) days from date of purchase or for the remainder of the limited warranty period of the equipment in which the component is installed.All in-warranty service calls must have prior authorization. For Authorization, call the Technical Support Department at 1-800-995-0417. Effective date of this policy is April 1, 2003.Additional conditions may apply. Go to www.wilburcurtis.com to view the full product warranty information.
CONDITIONS&EXCEPTIONSThe warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replace-ment parts installed on Curtis equipment that have not been purchased from theWilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances:
1) Improper operation of equipment: Theequipmentmustbeusedforitsdesignedandintendedpurposeandfunction.2) Improper installation of equipment: Thisequipmentmustbeinstalledbyaprofessionaltechnicianandmustcomplywithalllocalelectrical,
mechanicalandplumbingcodes.3) Improper voltage: Equipmentmustbeinstalledatthevoltagestatedontheserialplatesuppliedwiththisequipment.4) Improper water supply: This includes,but isnot limitedto,excessiveor lowwaterpressure,and inadequateorfluctuatingwaterflow
rate.5) Adjustments and cleaning: Theresettingofsafetythermostatsandcircuitbreakers,programmingandtemperatureadjustmentsarethe
responsibilityoftheequipmentowner.Theownerisresponsibleforpropercleaningandregularmaintenanceofthisequipment.6) Damaged in transit: Equipmentdamagedintransitistheresponsibilityofthefreightcompanyandaclaimshouldbemadewiththecar-
rier. 7) Abuse or neglect (including failure to periodically clean or remove lime accumulations): Manufacturerisnotresponsibleforvariation
inequipmentoperationduetoexcessivelimeorlocalwaterconditions.Theequipmentmustbemaintainedaccordingtothemanufacturer’srecommendations.
8) Replacement of items subject to normal use and wear: Thisshallinclude,butisnotlimitedto,lightbulbs,sheardisks,“0”rings,gaskets,siliconetube,canisterassemblies,whipperchambersandplates,mixingbowls,agitationassembliesandwhipperpropellers.
9) Repairs and/or Replacements aresubjecttoourdecisionthattheworkmanshiporpartswerefaultyandthedefectsshowedupundernormaluse.Alllaborshallbeperformedduringregularworkinghours.Overtimechargesaretheresponsibilityoftheowner.Chargesincurredbydelays,waitingtime,oroperatingrestrictionsthathindertheservicetechnician’sabilitytoperformserviceistheresponsibilityoftheowneroftheequipment.Thisincludesinstitutionalandcorrectionalfacilities.TheWilburCurtisCompanywillallowupto100miles,roundtrip,perin-warrantyservicecall.
RETURN MERCHANDISE AUTHORIZATION: AllclaimsunderthiswarrantymustbesubmittedtotheWilburCurtisCompanyTechnicalSupportDepartmentpriortoperforminganyrepairworkorreturnofthisequipmenttothefactory.Allreturnedequipmentmustberepackagedproperlyintheoriginalcarton.Nounitswillbeacceptediftheyaredamagedintransitduetoimproperpackaging.NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA). RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL. All in-warranty service calls must be performed by an authorized service agent. Call the Wilbur Curtis Technical Sup-port Department to find an agent near you.