Download - W&C Sec 7 Issue 5
-
5/26/2018 W&C Sec 7 Issue 5
1/68
7DS 02-527 (NES527) - Silicone Insulated,
LFH Sheathed
Single-Core & Multicore Unscreened. . . . . . . . . . . . 7:2
Single and Multipair Collectively Screened . . . . . . . 7:6
Multicore Individually Screened . . . . . . . . . . . . . . . 7:8
Multipair Individually Screened . . . . . . . . . . . . . . 7:10
Multicore Collectively Screened . . . . . . . . . . . . . . 7:12Miniature Multicore . . . . . . . . . . . . . . . . . . . . . . . 7:14
Miniature Multipair, Multitriple . . . . . . . . . . . . . . 7:16
DS 02-526 (NES526) - LFH Insulated and
Sheathed
Single-Core Stranded . . . . . . . . . . . . . . . . . . . . . . 7:18
Multicore Stranded . . . . . . . . . . . . . . . . . . . . . . . 7:20
Single-Core Flexible . . . . . . . . . . . . . . . . . . . . . . . 7:22
Three Core Flexible. . . . . . . . . . . . . . . . . . . . . . . . 7:24Multicore Stranded Cable (7 Core & Above) . . . . . 7:26
Multicore Special Flexing . . . . . . . . . . . . . . . . . . . 7:28
Multicore Collectively Screened Special Flexing. . . 7:30
Multicore Individually Screened Flexible . . . . . . . . 7:32
Multicore Collectively Screened . . . . . . . . . . . . . . 7:34
Multicore Collectively Screened Flexible . . . . . . . . 7:36
Multicore Armoured . . . . . . . . . . . . . . . . . . . . . . . 7:38
Technical Information for Cables . . . . . . . . . . . . . 7:40
DEF 61-12 Part 33 - ETFE
Single & Multicore Unscreened. . . . . . . . . . . . . . . 7:42
Single & Multicore Screened. . . . . . . . . . . . . . . . . 7:45
DEF 61-12 Part 25 - LFH Insulated and
Sheathed
Multicore Unscreened . . . . . . . . . . . . . . . . . . . . . 7:50
Multicore Screened . . . . . . . . . . . . . . . . . . . . . . . 7:53Multipair Collectively Screened . . . . . . . . . . . . . . 7:56
Multipair Individually Screened . . . . . . . . . . . . . . 7:58
Multipair Individually & Collectively Screened. . . . 7:60
Multitriple Collectively Screened . . . . . . . . . . . . . 7:62
Technical Information for DEF 61-12
Part 25 Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . 7:64
Coaxial Twinaxial and Triaxial
LFH Twinaxial . . . . . . . . . . . . . . . . . . . . . . . . . . 7:65LFH Coaxial and Triaxial . . . . . . . . . . . . . . . . . . 7:66
NSN Cross Reference Chart . . . . . . . . . . . . . . . . . 7:68
Cables for Use on Military Vessels
MilitaryV
essels
The following section covers cables for use on military vessels, e.g. HM Surface Ships, Submarines, etc. The
range covered is only part of the total designs of cable available and is intended as a guide to the most
popular types. The cables are covered by the following standards:- DEF61-12 - Defence Standard - wires, cords
& cables. DS (Defence Standard) N.B. DS, (Defence Standard) are former NES (Naval Engineering Standard).
-
5/26/2018 W&C Sec 7 Issue 5
2/68072
Products. Technology. Services. Delivered Globally.
anixter.com
Single-Core and Multicore Silicone Insulated,
LFH Sheathed Cables for Military Vessels
Military Vessels
DS 02-527 (NES527) 440 V 105C
Application
Fire resistant cable for power, control, lighting use, etc., in military vessels where the cable is required to retain circuit
integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited Fire Hazard)
sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductors: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation:
Up to & including 16mm2 - silicone rubber insulation to
BS7655 + fibre glass braid
and lacquer
25mm2 and above - silicone impregnated
glass tapes
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
3/68
Single-Core and Multicore Silicone Insulated,
LFH Sheathed Cables for Military VesselsDS 02-527 (NES527) 440 V 105C
073
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
Current
RatingA
-6808 -6808-M 1.0 7/0.44 1 0.5 5.60 17-6809 -6809-M 1.5 7/0.53 1 0.5 5.90 23-6810 -6810-M 2.5 7/0.67 1 0.6 6.50 33-6811 -6811-M 4.0 7/0.85 1 0.6 7.00 43-6812 -6812-M 6.0 7/1.04 1 0.7 7.80 55-6813 -6813-M 10 19/0.85 1 0.9 9.30 79-6814 -6814-M 16 19/1.04 1 0.9 10.30 100-6815 -6815-M 25 19/1.35 1 1.1 11.90 140-6816 -6816-M 35 19/1.53 1 1.1 12.80 165-6817 -6817-M 50 19/1.78 1 1.1 14.10 200
-6818 -6818-M 70 19/2.14 1 1.1 16.20 250-6819 -6819-M 95 37/1.78 1 1.4 18.70 315-6820 -6820-M 120 37/2.03 1 1.4 20.90 380-6821 -6821-M 150 37/2.25 1 1.4 22.40 420-6822 -6822-M 185 37/2.52 1 1.4 24.50 480-6823 -6823-M 240 61/2.25 1 1.4 27.30 560-6824 -6824-M 300 61/2.52 1 1.4 29.90 660
d.c. a.c.-6825 -6825-M 400 91/2.36 1 1.4 33.60 800 790-6826 -6826-M 500 91/2.65 1 1.4 37.20 940 890-6827 -6827-M 630 127/2.52 1 1.5 41.40 1110 970-6828 -6828-M 1.0 7/0.44 2 0.5 8.60 17-6829 -6829-M 1.5 7/0.53 2 0.5 9.10 23
-6830 -6830-M 2.5 7/0.67 2 0.6 10.40 33-6831 -6831-M 4.0 7/0.85 2 0.6 11.60 43-6832 -6832-M 6.0 7/1.04 2 0.7 13.10 55-6833 -6833-M 10 19/0.85 2 0.9 16.50 79-6834 -6834-M 16 19/1.04 2 0.9 18.60 100-6835 -6835-M 25 19/1.35 2 1.1 22.10 140-6836 -6836-M 35 19/1.53 2 1.1 24.10 165-6837 -6837-M 50 19/1.78 2 1.1 26.80 200-6838 -6838-M 70 19/2.14 2 1.1 30.60 250-6839 -6839-M 95 37/1.78 2 1.4 35.90 315-6840 -6840-M 1.0 7/0.44 3 0.5 9.10 17-6841 -6841-M 1.5 7/0.53 3 0.5 9.60 23
-6842 -6842-M 2.5 7/0.67 3 0.6 11.10 33-6843 -6843-M 4.0 7/0.85 3 0.6 12.20 43-6844 -6844-M 6.0 7/1.04 3 0.7 13.90 55-6845 -6845-M 10 19/0.85 3 0.9 17.70 79-6846 -6846-M 16 19/1.04 3 0.9 19.70 100-6847 -6847-M 25 19/1.35 3 1.1 23.70 140-6848 -6848-M 35 19/1.53 3 1.1 25.60 165-6849 -6849-M 50 19/1.78 3 1.1 28.70 200-6850 -6850-M 70 19/2.14 3 1.1 33.00 250-6851 -6851-M 95 37/1.78 3 1.4 38.50 315-6852 -6852-M 120 37/2.03 3 1.4 42.90 380-6853 -6853-M 150 37/2.25 3 1.4 46.40 420-6854 -6854-M 185 37/2.52 3 1.4 50.90 480
-6855 -6855-M 240 61/2.25 3 1.4 57.10 560
Continued overleaf...
-
5/26/2018 W&C Sec 7 Issue 5
4/68074
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Single-Core and Multicore Silicone Insulated,
LFH Sheathed Cables for Military Vessels
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DS 02-527 (NES527) 440 V 105C (continued)
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
Current
RatingA
-6856 -6856-M 16 19/1.04 7 0.9 29.50 60*-6857 -6857-M 25 19/1.35 7 1.1 35.30 84*-6858 -6858-M 35 19/1.53 7 1.1 38.60 90*-6859 -6859-M 50 19/1.78 7 1.1 43.30 120*-6860 -6860-M 70 19/2.14 7 1.1 49.80 150*-6861 -6861-M 4.0 7/0.85 14 0.6 22.50 22*-6862 -6862-M 6.0 7/1.04 14 0.7 26.30 25*-6863 -6863-M 10 19/0.85 14 0.9 33.70 40*-6864 -6864-M 16 19/1.04 14 0.9 38.30 50*-6865 -6865-M 25 19/1.35 14 1.1 45.90 70*
-6866 -6866-M 35 19/1.53 14 1.1 50.10 80*-6867 -6867-M 6.0 7/1.04 18 0.7 29.40 25*-6868 -6868-M 10 19/0.85 18 0.9 37.80 36*-6869 -6869-M 16 19/1.04 18 0.9 43.20 45*-6870 -6870-M 1.5 7/0.53 30 0.5 23.60 9*-6871 -6871-M 2.5 7/0.67 30 0.6 27.70 13*-6872 -6872-M 4 7/0.85 30 0.6 31.80 17*-6873 -6873-M 6 7/1.04 30 0.7 37.10 22*-6874 -6874-M 10 19/0.85 30 0.9 48.00 32*-6877 -6877-M 1.0 7/0.44 4 0.5 9.80 17-6878 -6878-M 1.0 7/0.44 5 0.5 10.80 17-6879 -6879-M 1.0 7/0.44 7 0.5 12.40 17-6880 -6880-M 1.0 7/0.44 10 0.5 14.20 17
-6881 -6881-M 1.0 7/0.44 14 0.5 15.50 17-6882 -6882-M 1.0 7/0.44 18 0.5 17.20 17-6883 -6883-M 1.0 7/0.44 24 0.5 20.10 17-6884 -6884-M 1.0 7/0.44 30 0.5 21.70 17-6885 -6885-M 1.0 7/0.44 36 0.5 23.20 17-6886 -6886-M 1.0 7/0.44 44 0.5 26.20 17-6889 -6889-M 2.5 7/0.67 4 0.6 12.00 33-6890 -6890-M 2.5 7/0.67 5 0.6 13.00 33-6891 -6891-M 2.5 7/0.67 7 0.6 15.60 33-6892 -6892-M 2.5 7/0.67 10 0.6 18.21 33-6893 -6893-M 2.5 7/0.67 14 0.6 19.70 33-6894 -6894-M 2.5 7/0.67 18 0.6 22.20 33
-6895 -6895-M 2.5 7/0.67 24 0.6 26.20 33-6897 -6897-M 2.5 7/0.67 36 0.6 30.00 33-6898 -6898-M 2.5 7/0.67 44 0.6 34.20 33-6901 -6901-M 4.0 7/0.85 4 0.6 13.30 43-6902 -6902-M 4.0 7/0.85 5 0.6 14.50 43-6903 -6903-M 4.0 7/0.85 7 0.6 17.70 43-6904 -6904-M 4.0 7/0.85 10 0.6 20.60 43-6906 -6906-M 4.0 7/0.85 18 0.6 25.10 43-6907 -6907-M 4.0 7/0.85 24 0.6 29.70 43-6909 -6909-M 4.0 7/0.85 36 0.6 34.40 43
-
5/26/2018 W&C Sec 7 Issue 5
5/68075
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Single-Core and Multicore Silicone Insulated,
LFH Sheathed Cables for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
The current ratings are for one core only carrying current. When more than one core carries current the following rating
factors should be applied.
Number of cores 2 3 4 7 14 18 30
Rating factor 0.8 0.7 0.7 0.6 0.5 0.45 0.4
* The current ratings are for each core when all cores are equally loaded.
N.B. All current ratings shown are based on an ambient air temperature of 50C. For ambient air temperatures other than 50C
the following rating factors should be applied.
Ambient air temp C 45 50 55 60 65 70 75 80 85 90 95 100
Rating factor 1.04 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.60 0.52 0.43 0.30
N.B. Details of weights for cables to DS 02-527 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
6/68076
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for control, instrumentation use, etc., in military vessels where the cable is required to retain circuit
integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited Fire Hazard)
sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
Pair Identification: Pairs shall be numbered and
printed thus:
1-pair - cores numbered 1 and 2
2-pair - cores numbered 1 and 2 for the first pair,
and 3 and 4 for the second pair
For a greater number of pairs the numbering shall be
similarly extended
Collective tinned copper wire braid screen
(minimum 0.61 filling factor)
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Single and Multipair Collectively Screened Silicone
Insulated, LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
7/68077
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Single and Multipair Collectively Screened Silicone
Insulated, LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Pairs
Insulation
Thicknessmm
Nominal
O/Dmm
-6910 -6910-M 1.0 7/0.44 1 0.5 9.10
-6911 -6911-M 1.0 7/0.44 2 0.5 14.30
-6912 -6912-M 1.0 7/0.44 3 0.5 15.20
-6913 -6913-M 1.0 7/0.44 4 0.5 15.80
-6914 -6914-M 1.0 7/0.44 7 0.5 18.70
-6915 -6915-M 1.0 7/0.44 11 0.5 25.00
-6916 -6916-M 1.0 7/0.44 16 0.5 27.60
-6917 -6917-M 1.0 7/0.44 19 0.5 29.00
N.B. Details of weights of cable to DS 02-527 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
8/68078
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for control, instrumentation use, etc., in military vessels where the cable is required to retain circuit
integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited Fire Hazard)
sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors to
BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
0.15mm tinned copper wire braid screen applied over
each core (minimum 0.61 filling factor)
Screen Isolation Tape: p.e.t.p. tape 50% overlap
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheathalso displays the following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Individually Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
9/68079
Products. Technology. Services. Delivered Globally.
anixter.com
N.B. Details of weights of cable to DS 02-527 are available on request.
Multicore Individually Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal O/D
mm
Current
RatingA
-6918 6918-M 1.0 7/0.44 3 0.5 11.10 17
-6919 6919-M 1.0 7/0.44 5 0.5 13.00 17
-6920 6920-M 1.0 7/0.44 7 0.5 15.50 17
-6921 6921-M 1.0 7/0.44 14 0.5 19.60 17
-6922 6922-M 1.0 7/0.44 18 0.5 22.20 17
The current ratings are for one core only carrying current. When more than one core carries current the following rating
factors should be applied.
Number of cores loaded 2 3 4 7 14 18
Rating factor 0.8 0.7 0.7 0.6 0.5 0.45
N.B. All current ratings shown are based on an ambient air temperature of 50C. For ambient air temperatures other than 50C
the following rating factors should be applied.
Ambient air temp C 45 50 55 60 65 70 75 80 85 90 95 100
Rating factor 1.04 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.60 0.52 0.43 0.30
-
5/26/2018 W&C Sec 7 Issue 5
10/680710
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for control, instrumentation use, etc., in military vessels where the cable is required to retain circuit
integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited Fire Hazard)
sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
0.15mm tinned copper wire braid applied over each pair
(minimum 0.5 filling factor)
Screen Isolation Tape: p.e.t.p. tape 50% overlap
Pair Identification: Pairs shall be numbered and
printed thus:
1-pair - cores numbered 1 and 2
2-pair - cores numbered 1 and 2 for the first pair, and 3
and 4 for the second pair
For a greater number of pairs the numbering shall be
similarly extended
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multipair Individually Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
11/680711
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multipair Individually Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Pairs
Insulation
Thicknessmm
Nominal
O/Dmm
-6924 -6924-M 1.0 7/0.44 3 0.5 14.90
-6925 -6925-M 1.0 7/0.44 4 0.5 16.30
-6926 -6926-M 1.0 7/0.44 7 0.5 19.70
N.B. Details of weights of cable to DS 02-527 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
12/680712
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for power, control, lighting use, etc., in military vessels where the cable is required to retain circuit
integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited Fire Hazard)
sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
Core Identification: Cores shall be number printed
Collective tinned copper wire braid screen
(minimum 0.61 filling factor)
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Collectively Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
13/680713
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Collectively Screened Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
Number6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
Current
RatingA*
- 6928 - 6928-M 1.0 7/0.44 8 0.5 14.40 9
- 6929 - 6929-M 1.0 7/0.44 12 0.5 16.00 9
- 6930 - 6930-M 1.0 7/0.44 14 0.5 16.70 9
- 6931 - 6931-M 2.5 7/0.67 4 0.6 13.00 21
- 6932 - 6932-M 4.0 7/0.85 2 0.6 12.60 34
- 5869* - 5869-M 10 19/0.85 2 0.9 17.70 63
* NSN for this cable is 6145-99-529-5869. Anixter Part No: A10DW-529-5869-M.
N.B. Details of weights of cable to DS 02-527 are available on request.
* The current ratings are for each core when all cores are equally loaded.
N.B. All current ratings shown are based on an ambient air temperature of 50C. For ambient air temperatures other than
50C the following rating factors should be applied.
Ambient air temp C 45 50 55 60 65 70 75 80 85 90 95 100
Rating factor 1.04 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.60 0.52 0.43 0.30
-
5/26/2018 W&C Sec 7 Issue 5
14/680714
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for control, instrumentation, communication use, etc., in military vessels where the cable is required to
retain circuit integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH
(Limited Fire Hazard) sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
OPTIONAL: 0.15mm tinned copper wire braid applied over
each core (minimum 0.61 filling factor)
Screen Isolation Tape: p.e.t.p. tape 50% overlap
(on individually screened types only)
Core Identification: Cores shall be colour coded
as follows:
2 core - red, blue
3 core - red, blue, natural
Multicore cables - red, blue marker cores adjacent in
each layer with remaining cores natural
OPTIONAL: Collective tinned copper wire braid screen
(minimum 0.61 filling factor)
Outer Sheath: Black LFH (Limited Fire Hazard) outer
sheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Miniature Multicore Silicone Insulated,
LFH Sheathed Cable for Military VesselsUn-screened, or Individually Screened, or Collectively Screened DS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
15/680715
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Miniature Multicore Silicone Insulated,
LFH Sheathed Cable for Military VesselsUn-screened, or Individually Screened, or Collectively Screened DS 02-527 (NES527) 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
Number6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
Current
RatingA
* -6970 -6970-M 0.35 19/0.15 2 0.35 6.20 6
** -6971 -6971-M 0.35 19/0.15 2 0.35 7.00 6
*** -6972 -6972-M 0.35 19/0.15 2 0.35 7.40 6
* -6973 -6973-M 0.35 19/0.15 3 0.35 6.50 6
** -6974 -6974-M 0.35 19/0.15 3 0.35 7.30 6
*** -6975 -6975-M 0.35 19/0.15 3 0.35 7.80 6
* -6976 -6976-M 0.35 19/0.15 4 0.35 7.00 6
** -6977 -6977-M 0.35 19/0.15 4 0.35 7.80 6
*** -6978 -6978-M 0.35 19/0.15 4 0.35 8.40 6* -6979 -6979-M 0.35 19/0.15 6 0.35 8.10 6
** -6980 -6980-M 0.35 19/0.15 6 0.35 9.00 6
*** -6981 -6981-M 0.35 19/0.15 6 0.35 10.10 6
* -6982 -6982-M 0.35 19/0.15 12 0.35 10.40 6
** -6983 -6983-M 0.35 19/0.15 12 0.35 11.30 6
*** -6984 -6984-M 0.35 19/0.15 12 0.35 13.20 6
* -6985 -6985-M 0.35 19/0.15 18 0.35 12.30 6
** -6986 -6986-M 0.35 19/0.15 18 0.35 13.30 6
*** -6987 -6987-M 0.35 19/0.15 18 0.35 15.50 6
* -6988 -6988-M 0.35 19/0.15 25 0.35 14.10 6** -6989 -6989-M 0.35 19/0.15 25 0.35 15.30 6
*** -6990 -6990-M 0.35 19/0.15 25 0.35 18.20 6
** -6991 -6991-M 0.35 19/0.15 36 0.35 17.50 6
* -6992 -6992-M 0.35 19/0.15 60 0.35 20.40 6
** -6993 -6993-M 0.35 19/0.15 60 0.35 21.60 6
* Un-screened ** Collectively screened only *** Individually screened only.
The current ratings are for one core only carrying current. When more than one core carries current the following rating
factors should be applied:
Number of cores loaded 2 3 4 7 14 18 30
Rating factor 0.8 0.7 0.7 0.6 0.5 0.45 0.4
N.B. All current ratings shown are based on an ambient air temperature of 50C. For ambient air temperatures other than 50C
the following rating factors should be applied.
Ambient air temp C 45 50 55 60 65 70 75 80 85 90 95 100
Rating factor 1.04 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.60 0.52 0.43 0.30
N.B. Details of weights of cable to DS 02-527 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
16/680716
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Fire resistant cable for control, instrumentation communication use, etc., in military vessels where the cable is required to
retain circuit integrity in the event of a fire, for emergency lighting, alarms, shutdown systems etc. Incorporates LFH (Limited
Fire Hazard) sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Specifications
In accordance with DS 02-527
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Silicone rubber insulation to BS7655 + fibre
glass braid and lacquer
Pair Identification: Pairs shall be colour coded
as follows:
1-pair - red/blue
2-pair - red/blue and blue/black
3-pair and above - red/black and blue/black marker pairs
in each layer, with remaining pairs natural/black
Triple Identification:Triples shall be colour coded
as follows:
1 triple - red/blue/natural
Multitriple - each triple shall be coloured as above and
shall be lapped with a numbered p.e.t.p. tape
Collective tinned copper wire braid screen (minimum 0.61
filling factor)
Outer Sheath: Black LFH (Limited Fire Hazard) outersheath to DEF61-12 part 31. In addition, the outer sheath
also displays the following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-3-23 NMV 3.5
(IEC60332-3-23 Category B) as a minimum
Meets 3 hour 750C fire test (identical to IEC60331)
Voltage Rating: 440 V
Temperature Rating: 105C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Miniature Multipair, Multitriple, Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) Collectively Screened 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
17/680717
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Miniature Multipair, Multitriple, Silicone Insulated,
LFH Sheathed Cable for Military VesselsDS 02-527 (NES527) Collectively Screened 440 V 105C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Pairs/Triples
Insulation
Thicknessmm
Nominal
O/Dmm
-6995 -6995-M 0.35 19/0.15 2PR 0.35 9.60
-6996 -6996-M 0.35 19/0.15 3PR 0.35 10.20
-6997 -6997-M 0.35 19/0.15 5PR 0.35 12.10
-6998 -6998-M 0.35 19/0.15 11PR 0.35 17.30
-6999 -6999-M 0.35 19/0.15 25PR 0.35 23.00
-7001 -7001-M 0.35 19/0.15 2TR 0.35 11.90
-7002 -7002-M 0.35 19/0.15 3TR 0.35 12.20
-7003 -7003-M 0.35 19/0.15 4TR 0.35 13.40
-7004 -7004-M 0.35 19/0.15 7TR 0.35 15.80
N.B. Details of weights of cable to DS 02-527 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
18/680718
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Single-core cables for power, lighting, control circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire Hazard)
insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed applications and
suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Single-Core LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
19/680719
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Single-Core LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
-8252 -8252-M 1.0 7/0.44 1 0.8 5.30
-8253 -8253-M 1.5 7/0.53 1 0.8 5.50
-8254 -8254-M 2.5 7/0.67 1 0.8 6.00
-8255 -8255-M 4.0 7/0.85 1 1.0 6.90
-8256 -8256-M 6.0 7/1.04 1 1.0 7.50
-8257 -8257-M 10 7/1.35 1 1.2 9.00
-8258 -8258-M 16 7/1.70 1 1.2 10.10
-8259 -8259-M 25 19/1.35 1 1.4 12.40
-8260 -8260-M 35 19/1.53 1 1.4 13.30
-8261 -8261-M 50 19/1.78 1 1.6 15.20
-8262 -8262-M 70 19/2.14 1 1.6 17.20
-8263 -8263-M 95 37/1.78 1 1.8 19.30
-8264 -8264-M 120 37/2.03 1 1.8 21.40
-8265 -8265-M 150 3 7/2.25 1 2.0 23.50
-8266 -8266-M 185 37/2.52 1 2.2 26.00
-8267 -8267-M 240 61/2.25 1 2.4 29.20
-8268 -8268-M 300 61/2.52 1 2.6 32.30
-8269 -8269-M 400 91/2.36 1 2.8 36.40
-8270 -8270-M 500 91/2.65 1 3.0 40.20
-8271 -8271-M 630 127/2.52 1 3.0 44.10
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
20/680720
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore cables for power, lighting, control, circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire Hazard)
insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed applications and
suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
21/680721
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
-8275 -8275-M 4.0 7/0.85 2 1.0 12.00
-8276 -8276-M 6.0 7/1.04 2 1.0 13.10
-8277 -8277-M 10 7/1.35 2 1.2 16.00
-8278 -8278-M 16 7/1.70 2 1.2 18.30
-8279 -8279-M 25 19/1.35 2 1.4 22.90
-8280 -8280-M 35 19/1.53 2 1.4 24.70
-8281 -8281-M 50 19/1.78 2 1.6 28.40
-8282 -8282-M 70 19/2.14 2 1.6 32.30
-8283 -8283-M 95 37/1.78 2 1.8 37.00
-8284 -8284-M 120 37/2.03 2 1.8 40.80
-8285 -8285-M 150 37/2.25 2 2.0 45.10
-8289 -8289-M 4.0 7/0.85 3 1.0 12.70
-8290 -8290-M 6.0 7/1.04 3 1.0 13.90
-8291 -8291-M 10 7/1.35 3 1.2 17.20
-8292 -8292-M 16 7/1.70 3 1.2 19.50
-8293 -8293-M 25 19/1.35 3 1.4 24.40
-8294 -8294-M 35 19/1.53 3 1.4 26.50
-8295 -8295-M 50 19/1.78 3 1.6 30.30
-8296 -8296-M 70 19/2.14 3 1.6 34.70
-8297 -8297-M 95 37/1.78 3 1.8 39.70
-8298 -8298-M 120 37/2.03 3 1.8 43.80
-8299 -8299-M 150 37/2.25 3 2.0 48.40
-8300 -8300-M 185 37/2.52 3 2.2 53.90
-8301 -8301-M 240 61/2.25 3 2.4 61.10
N.B. Multicore cable (seven core and above) also available. Refer to page 7:26.Collective tinned copper wire braid cables also available on certain sizes.
Details available upon request.
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
22/680722
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Single-core cables having flexible conductors for power, lighting, control, circuits in HM surface ships and vessels. Incorporates
LFH (Limited Fire Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in
flexing or fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Single-Core Flexible LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
23/680723
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Single-Core Flexible LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
-8326 -8326-M 1.0 32/0.2 1 0.80 4.80
-8327 -8327-M 1.5 30/0.25 1 0.80 5.10
-8328 -8328-M 2.5 50/0.25 1 0.90 5.70
-8329 -8329-M 4.0 56/0.3 1 1.0 6.50
-8330 -8330-M 6.0 84/0.3 1 1.0 8.30
-8331 -8331-M 10 80/0.4 1 1.2 9.80
-8332 -8332-M 16 126/0.4 1 1.2 10.90
-8333 -8333-M 25 196/0.4 1 1.4 13.50
-8334 -8334-M 35 276/0.4 1 1.4 14.90
-8335 -8335-M 50 396/0.4 1 1.6 17.40
-8336 -8336-M 70 360/0.5 1 1.6 19.70
-8337 -8337-M 95 475/0.5 1 1.8 22.70
-8484 -8484-M 150 756/0.5 1 2.0 27.00
-8485 -8485-M 185 925/0.5 1 2.2 29.60
-8338 -8338-M 240 1221/0.5 1 2.4 33.50
523-2806* 523-2806-M* 300 1525/0.5 1 2.6 37.20
-8339 -8339-M 630 2257/0.6 1 3.0 50.20
* 523 replaces the 521 prefix on this type.
dimensions quoted against these types are maximum overall diameters.
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
24/680724
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Three Core Flexible LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Application
Three core cables having flexible conductors for power circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire
Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed or flexible
applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
-
5/26/2018 W&C Sec 7 Issue 5
25/680725
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Three Core Flexible LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Maximum*
O/Dmm
-8532 -8532-M 95 475/0.5 3 1.8 49.9
-8533 -8533-M 150 756/0.5 3 2.0 59.3
-8534 -8534-M 240 1221/0.5 3 2.4 73.2
* If optional binder tape is used over laid up cores, diameter is increased by 0.3mm.
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
26/680726
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore cables for power, lighting, control circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire Hazard)
insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed applications and
suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
27/680727
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore LFH Insulated and Sheathed
Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
-8402 -8402-M 4.0 7/0.85 7 1.0 16.7
-8403 -8403-M 6.0 7/1.04 7 1.0 18.6
-8404 -8404-M 10 7/1.35 7 1.2 23.1
-8405 -8405-M 16 7/1.70 7 1.2 26.5
-8406 -8406-M 25 19/1.35 7 1.4 33.1
-8407 -8407-M 35 19/1.53 7 1.4 36.2
-8408 -8408-M 50 19/1.78 7 1.6 41.5
-8409 -8409-M 70 19/2.14 7 1.6 47.5
-8410 -8410-M 4.0 7/0.85 14 1.0 23.9
-8411 -8411-M 6.0 7/1.04 14 1.0 26.6
-8412 -8412-M 10 7/1.35 14 1.2 33.0
-8413 -8413-M 16 7/1.70 14 1.2 38.0
-8414 -8414-M 25 19/1.35 14 1.4 48.0
-8415 -8415-M 2.5 7/0.67 18 0.8 21.6
-8416 -8416-M 4.0 7/0.85 18 1.0 26.7
-8417 -8417-M 6.0 7/1.04 18 1.0 29.8
-8418 -8418-M 10 7/1.35 18 1.2 37.1
-8419 -8419-M 16 7/1.70 18 1.2 42.9
-8420 -8420-M 2.5 7/0.67 30 0.8 27.1
-8421 -8421-M 4.0 7/0.85 30 1.0 33.9
-8422 -8422-M 6.0 7/1.04 30 1.0 37.7
-8423 -8423-M 10 7/1.35 30 1.2 47.2
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
28/680728
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore special flexing cables for power, lighting, control circuits in HM surface ships and vessels. Incorporates LFH (Limited
Fire Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed or flexible
applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Special Flexing LFH Insulated
and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
29/680729
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Special Flexing LFH Insulated
and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Nominal
O/Dmm
-8486 -8486-M 1.0 32/0.2 2 0.8 8.5
-8487 -8487-M 1.5 30/0.25 2 0.8 9.1
-8488 -8488-M 2.5 50/0.25 2 0.9 10.6
-8345 -8345-M 4.0 56/0.3 2 1.0 12.4
-8489 -8489-M 2.5 50/0.25 3 0.9 11.2
-8351 -8351-M 4.0 56/0.3 3 1.0 13.1
-8490 -8490-M 6.0 84/0.3 3 1.0 16.4*
-8491 -8491-M 16 126/0.4 3 1.2 30.7*
-8492 -8492-M 35 276/0.4 3 1.4 38.7*
-8493 -8493-M 95 475/0.5 3 1.8 55.9*
-8494 -8494-M 2.5 50/0.25 4 0.9 12.4
-8495 -8495-M 4.0 56/0.3 4 1.0 14.5
-8496 -8496-M 2.5 50/0.25 5 0.9 13.4
-8497 -8497-M 1.5 30/0.25 8 0.8 16.2-8498 -8498-M 2.5 50/0.25 8 0.9 18.6
-8499 -8499-M 4.0 56/0.3 8 1.0 21.8
-8500 -8500-M 2.5 50/0.25 10 0.9 20.2
-8501 -8501-M 4.0 56/0.3 10 1.0 23.7
-8502 -8502-M 1.5 30/0.25 15 0.8 20.2
-8503 -8503-M 2.5 50/0.25 15 0.9 23.3
-8504 -8504-M 1.5 30/0.25 22 0.8 25.1-8505 -8505-M 2.5 50/0.25 22 0.9 29.1
-8506 -8506-M 1.5 30/0.25 30 0.8 26.7
-8507 -8507-M 2.5 50/0.25 30 0.9 31.1
-8508 -8508-M 2.5 50/0.25 36 0.9 33.7
* Dimensions quoted against these types are maximum overall diameters.
N.B. Details of weights of cable to DS 02-526 are available on request.
3 core 16, 35 and 95mm2 cables incorporate cradle centres.
-
5/26/2018 W&C Sec 7 Issue 5
30/680730
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore special flexing collectively screened cables for power, lighting, control circuits in HM surface ships and vessels.
Incorporates LFH (Limited Fire Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed or flexible applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Collective tinned copper wire braid screen (minimum 0.61
filling factor)
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or between
cores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Collectively Screened Special Flexing LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
31/680731
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Collectively Screened Special Flexing LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Braid Wire
Sizemm
Nominal
O/Dmm
-8509 -8509-M 2.5 50/0.25 2 0.9 7/0.15 13.0
-8510 -8510-M 1.0 32/0.2 3 0.8 7/0.15 11.5
-8511 -8511-M 2.5 50/0.25 3 0.9 7/0.15 13.6
-8512 -8512-M 2.5 50/0.25 4 0.9 7/0.15 14.8
-8513 -8513-M 0.75 24/0.2 8 0.8 14/0.15 17.8
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
32/680732
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore individually screened cables for control circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire
Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed or flexible
applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Composite tinned copper - nylon braid applied over each
individual core (minimum 0.61 filling factor)
Outer Sheath: Black LFH outer sheath to DEF61-12part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or betweencores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Individually Screened Flexible LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
33/680733
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Individually Screened Flexible LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter Number
A10DW-521
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Copper Braid
Wire Size**mm
Nominal
O/Dmm
-8470 -8470-M 0.75 24/0.2 3 0.8 0.2 10.9
-8471 -8471-M 0.75 24/0.2 5 0.8 0.2 13.2
-8472 -8472-M 0.75 24/0.2 7 0.8 0.2 15.9
-8473 -8473-M 0.75 24/0.2 14 0.8 0.2 20.3
-8474 -8474-M 0.75 24/0.2 19 0.8 0.2 24.2
N.B. Details of weights of cable to DS 02-526 are available on request.
** Braid consists of: 8 spindles tinned copper wire L/H.
8 spindles 140 denier nylon R/H.
-
5/26/2018 W&C Sec 7 Issue 5
34/680734
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore collectively screened cables for power and control circuits in HM surface ships and vessels. Incorporates LFH
(Limited Fire Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed
or flexible applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Stranded Class 2 or flexible Class 5 tinned
copper conductors to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed.
Collective tinned copper wire braid screen
(minimum 0.61 filling factor)
Outer Sheath: Black LFH outer sheath to DEF61-12part 31. In addition, the outer sheath also displays the
following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)
as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or betweencores and ships structure, or between cores and
cable screen) Temperature Rating: 85C maximum conductor
operating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Collectively Screened LFH Insulated
and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
35/680735
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Collectively Screened LFH Insulated
and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-
Anixter Number
A10DW-
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Copper Braid
Wire Sizemm
Nominal
O/Dmm
521-8463 521-8463-M 4.0 7/0.85 2 1.0 0.2 13.4
521-8464 521-8464-M 16 7/1.70 2 1.2 0.3 20.5
531-0227 531-0227-M 10 7/1.35 3 1.2 0.2 18.7
531-0228 531-0228-M 16 7/1.70 3 1.2 0.3 21.9
531-0229 531-0229-M 25 19/1.35 3 1.4 0.3 26.7
531-0230 531-0230-M 35 19/1.53 3 1.4 0.3 28.8
531-0231 531-0231-M 50 19/1.78 3 1.6 0.4 33.3
521-8530 521-8530-M 1.0 32/0.2 4 1.6 0.2 15.4
521-8466 521-8466-M 2.5 7/0.67 4 0.8 0.2 13.0
521-8531 521-8531-M 6.0 84/0.3 4 2.5 0.3 27.2*
531-7042 531-7042-M 0.5 16/0.2 19 0.8 0.2 18.3
531-7043 531-7043-M 0.5 16/0.2 27 0.8 0.3 21.3
531-7044 531-7044-M 0.5 16/0.2 37 0.8 0.3 24.5
N.B. Details of weights of cable to DS 02-526 are available on request.
* Maximum overall diameter
Cables 531-0227 to 531-0231 have minimum braid filling factor of 0.7.
Cables 521-8530 and 521-8531 to have cores coloured: brown, yellow, blue, green.
Cable 521-8530 rated at 750 V.
Cable 521-8531 rated at 1100 V.
-
5/26/2018 W&C Sec 7 Issue 5
36/680736
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore collectively screened cables for control circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire
Hazard) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed or flexible
applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Flexible Class 5 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification:2 core - blue, brown
3 core - green/yellow, blue, brown
4 core - green/yellow, black, blue, brown
5 core - green/yellow, black, blue, brown, black
7 core - cores shall be number printed
Outer Sheath: Black LFH sheath to DEF61-12 part 31.In addition, the sheath also displays the following
characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Collective tinned copper wire braid screen
(minimum 0.61 filling factor) Braid is left bare
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or betweencores and ships structure, or between cores and
cable screen)
Temperature Rating: 85C maximum conductoroperating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Collectively Screened Flexible LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
37/680737
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Collectively Screened Flexible LFH
Insulated and Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-
Anixter Number
A10DW-
Nominal Cond
Areamm2
Nominal Cond
Stranding#/mm
Number of
Cores
Insulation
Thicknessmm
Copper Braid
Wire Sizemm
Nominal
O/Dmm
521-8371 521-8371-M 0.5 16/0.2 2 0.8 0.2 8.3
521-8373 521-8373-M 1.0 32/0.2 2 0.8 0.2 9.1
521-8374 521-8374-M 1.5 30/0.25 2 0.8 0.2 9.9
521-8375 521-8375-M 2.5 50/0.25 2 0.9 0.2 11.4
521-8376 521-8376-M 0.5 16/0.2 3 0.8 0.2 8.7
521-8378 521-8378-M 1.0 32/0.2 3 0.8 0.2 9.8
521-8379 521-8379-M 1.5 30/0.25 3 0.8 0.2 10.4
521-8381 521-8381-M 0.75 24/0.2 4 0.8 0.2 10.4
521-8382 521-8382-M 0.5 16/0.2 5 0.8 0.2 10.3
521-8383 521-8383-M 0.5 16/0.2 7 0.8 0.2 12.2
N.B. Details of weights of cable to DS 02-526 are available on request.
Cores may be supplied with black insulation printed with the core colour, e.g. BLUE, etc.
-
5/26/2018 W&C Sec 7 Issue 5
38/680738
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore armoured cables for power circuits in HM surface ships and vessels. Incorporates LFH (Limited Fire Hazard)
insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire. For use in fixed applications and
suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.
Specifications
In accordance with DS 02-526
Conductor: Stranded Class 2 tinned copper conductors
to BS EN 60228
Insulation: Dual layer LFH insulation to DS 02-526
Core Identification: Cores shall be number printed
Inner Sheath: Black LFH inner sheath toDEF61-12 part 31
Galvanised steel wire braid armour (minimum 0.61
filling factor)
Outer Sheath: Black LFH outer sheath to DEF61-12
part 31. In addition, the inner and outer sheath alsodisplay the following characteristics:
Minimum oxygen index: 30%
Maximum HCL emission @ 800C: 0.5%
Flame retardant to BS EN 60332-1-2 for completed cables
with individual conductor size less than 4mm2.
BS EN 60332-3-23 NMV 3.5 (IEC60332-3-23 Category B)as a minimum, for completed cables with individual
conductor sizes 4mm2 and greater
Voltage Rating: 440 Vrms (between cores, or betweencores and ships structure, or between cores and
cable screen)
Temperature Rating: 85C maximum conductoroperating temperature
N.B. Cables also retain a degree of flexibility under
weatherdeck conditions of -30C.
Multicore Armoured LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
39/680739
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Multicore Armoured LFH Insulated and
Sheathed Cable for Military VesselsDS 02-526 (NES526) 440 V 85C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
N.S.N.
6145-99-521
Anixter
NumberA10DW-521
Nominal
Cond Area
mm2
Nominal
CondStranding#/mm
Number of
Cores
Insulation
Thickness
mm
Nominal
Diam OverInner Sheathmm
Braid
Wire Size
mm
Nominal
O/D
mm
-8424 -8424-M 35 19/1.35 7 1.4 35.55 0.45 44.3
-8425 -8425-M 70 19/2.14 7 1.6 46.7 0.45 56.6
-8426 -8426-M 150 37/2.25 7 2.0 65.65 0.45 77.4
N.B. Details of weights of cable to DS 02-526 are available on request.
-
5/26/2018 W&C Sec 7 Issue 5
40/680740
Products. Technology. Services. Delivered Globally.
anixter.com
Technical InformationMilitary Vessels
for DS 02-526 (NES526) Cables
Conductor Size mm2 Current Rating *A
1.0 17
1.5 23
2.5 33
4.0 43
6.0 55
10 79
16 100
25 140
35 165
50 200
70 250
95 315
120 380
150 420
185 480
240 560
300 660
* The ratings quoted are based on 40C ambient air temperature and assume only one core carrying current. When more thanone core carries current the following factors should be applied:
Number of cores loaded 2 3 4 7 14 18 30
Rating factor 0.8 0.7 0.7 0.6 0.5 0.45 0.4
Ambient air temp C 30 40 45 50 55 60 65 70
Rating factor 1.05 1.0 0.94 0.88 0.82 0.75 0.67 0.58
Up to 10mm 10.1 to 25.4mm Above 25.4mm
O/D O/D O/D
Non-armoured cables 3D 4D 6D
Braid screened cables 6D 6D 6D
CURRENT RATINGS
MINIMUM BEND RADIUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
-
5/26/2018 W&C Sec 7 Issue 5
41/680741
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Cables to DS 02-517, DS 02-643 and
DS 02-525 Issue 3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Anixter stock a select range of the above cables in accordance with the following Nato Stock Numbers:
DS 02-517 DS 02-643* DS 02-525 Issue 3*
6145-99-521-7006 6145-99-096-2821 6145-99-300-3357
6145-99-521-7007 6145-99-172-8995 6145-99-438-6390
6145-99-521-7009 6145-99-442-3510 6145-99-495-8660
6145-99-521-7010 6145-99-701-4332 6145-99-663-3453
6145-99-521-7012 6145-99-708-9552 6145-99-708-9090
6145-99-521-7013 6145-99-743-5422 6145-99-724-8836
6145-99-521-8346 6145-99-765-4033 6145-99-724-8840
6145-99-521-8349 6145-99-967-9941 6145-99-724-88426145-99-523-6543 6145-99-724-8843
6145-99-527-6195 6145-99-902-1196
6145-99-527-6196
6145-99-527-6203
6145-99-527-8993
6145-99-537-4978
6145-99-539-1275
6145-99-539-1276
6145-99-543-44756145-99-724-8826
6145-99-724-8831
6145-99-724-8832
6145-99-724-8833
6145-99-724-8834
N.B. Details on the above cables are available on request.
* N.B. These cables are now covered in DEF61-12 Part 25 Issue 5.
-
5/26/2018 W&C Sec 7 Issue 5
42/680742
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore, Unscreened Equipment Wire & Cable600 V 135C or 150C
Application
For use as general airframe wires and cables, incorporating unique properties and construction for that purpose e.g. thin-wall,
lightweight etc.
Specifications
In accordance with DEF STAN 61-12 Part 33
Supplement 001
Conductors: Stranded tin or silver plated copperconductors in accordance with EN 2083
Insulation: Extruded XLETFE (cross-linked ETFE) for
Type 2 cores Core Identification:
Single-Core - white
Two Core - red, blue
Three Core - red, blue, yellow
Four Core -red, blue, yellow, green
Flame retardant to DEF STAN 61-12 Part 0, clauses 13.39
and 13.40. (10 second flame application)
Temperature Rating: 135C or 150C max conductoroperating temperature as indicated, -55C for low
temperature applications
Voltage Rating: 600 Vrms
-
5/26/2018 W&C Sec 7 Issue 5
43/680743
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore, Unscreened Equipment Wire & Cable600 V 135C or 150C
AnixterPartNumberA10DW-
Cond Type N.S.N.6145-99-
Cond SizeCode
NominalCondArea
AWG
NominalCondArea
mm2
NominalCondStranding
#/mm
MinO/D
mm
MaxO/D
mm
ApproxCableWeight
kg/km
Max. d.c.ConductorResistance@20C
ohms/km
Single-Core, 135C Rated, Unscreened & Unjacketed
038-3910 P 038-3910 001 26 0.15 19/0.10 0.83 0.92 2.10 149.0
038-3911 P 038-3911 002 24 0.20 19/0.12 0.93 1.02 2.84 106.0
038-3912 T 038-3912 004 22 0.35 19/0.15 1.10 1.17 4.10 60.0
038-3913 T 038-3913 006 20 0.60 19/0.20 1.42 1.52 6.95 33.2
038-3914 T 038-3914 010 18 0.95 19/0.25 1.60 1.68 9.80 21.1
038-3915 T 038-3915 012 16 1.35 19/0.29 1.75 1.85 12.99 15.8
038-3916 T 038-3916 020 14 1.80 37/0.25 2.14 2.28 18.68 10.9
038-3917 T 038-3917 030 12 3.00 37/0.32 2.58 2.73 28.62 6.8
038-3918 T 038-3918 050 10 5.00 37/0.40 3.15 3.61 48.80 4.2
Two Core, 135C Rated, Unscreened & Unjacketed
038-3926 P 038-3926 002 24 0.20 19/0.25 - 2.26 6.70 106.0
038-3927 T 038-3927 004 22 0.35 19/0.40 - 2.52 9.23 60.0
038-3928 T 038-3928 006 20 0.60 19/0.20 - 3.00 14.45 33.2
038-3929 T 038-3929 010 18 0.95 19/0.25 - 3.48 21.29 21.1
038-3930 T 038-3930 012 16 1.35 19/0.29 - 3.74 26.32 15.8
Three Core, 135C Rated, Unscreened & Unjacketed
038-3936 T 038-3936 004 22 0.35 19/0.40 - 2.72 13.85 60.0
038-3937 T 038-3937 006 20 0.60 19/0.20 - 3.24 21.67 33.2
038-3938 T 038-3938 010 18 0.95 19/0.25 - 3.76 31.93 21.1
038-3939 T 038-3939 012 16 1.35 19/0.29 - 4.04 39.48 15.8
038-3940 T 038-3940 020 14 1.80 37/0.25 - 5.27 62.51 10.9
Single-Core, 150C Rated, Unscreened & Unjacketed
038-4048 P 038-4048 001 26 0.15 19/0.10 0.83 1.00 2.31 149.0
038-4049 P 038-4049 002 24 0.20 19/0.12 0.93 1.16 3.28 106.0038-4050 S 038-4050 004 22 0.35 19/0.15 1.10 1.17 4.10 55.3
038-4051 S 038-4051 006 20 0.60 19/0.20 1.42 1.52 6.95 31.0
038-4052 S 038-4052 010 18 0.95 19/0.25 1.60 1.68 9.80 19.6
038-4053 S 038-4053 012 16 1.35 19/0.29 1.75 1.85 12.99 14.9
038-4054 S 038-4054 020 14 1.80 37/0.25 2.14 2.28 18.68 10.2
038-4055 S 038-4055 030 12 3.00 37/0.32 2.58 2.73 28.62 6.4
038-4056 S 038-4056 050 10 5.00 37/0.40 3.15 3.61 48.80 4.0
-
5/26/2018 W&C Sec 7 Issue 5
44/680744
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore, Unscreened Equipment Wire & Cable600 V 135C or 150C
P = silver plated high strength copper alloy (SPHSCA)
T = tin plated copper
S = silver plated copper
AnixterPartNumberA10DW-
Cond Type N.S.N.6145-99-
Cond SizeCode
NominalCondArea
AWG
NominalCondArea
mm2
NominalCondStranding
#/mm
MinO/D
mm
MaxO/D
mm
ApproxCableWeight
kg/km
Max. d.c.ConductorResistance@20C
ohms/km
Two Core, 150C Rated, Unscreened & Unjacketed
038-4063 P 038-4063 001 26 0.15 19/0.10 - 2.00 4.69 149.0
038-4064 P 038-4064 002 24 0.20 19/0.12 - 2.32 6.65 106.0
038-4065 S 038-4065 004 22 0.35 19/0.15 - 2.52 9.23 55.3
038-4065 S 038-4065 006 20 0.60 19/0.20 - 3.00 14.49 31.0
038-4066 S 038-4066 010 18 0.95 19/0.25 - 3.48 21.29 19.6
038-4067 S 038-4067 012 16 1.35 19/0.29 - 3.74 27.37 14.9
Three Core, 150C Rated, Unscreened & Unjacketed
038-4072 P 038-4072 001 26 0.15 19/0.10 - 2.16 7.04 149.0
038-4073 P 038-4073 002 24 0.20 19/0.12 - 2.51 9.97 106.0
038-4074 S 038-4074 004 22 0.35 19/0.15 - 2.72 13.85 55.3
038-4075 S 038-4075 006 20 0.60 19/0.20 - 3.24 21.74 31.0
038-4076 S 038-4076 010 18 0.95 19/0.25 - 3.76 31.93 19.6
038-4077 S 038-4077 012 16 1.35 19/0.29 - 4.41 41.05 14.9
Four Core, 150C Rated, Unscreened & Unjacketed
038-4081 P 038-4072 001 26 0.15 19/0.10 - 2.42 9.39 149.0
038-4082 P 038-4073 002 24 0.20 19/0.12 - 2.81 13.30 106.0
038-4083 S 038-4074 004 22 0.35 19/0.15 - 3.05 18.47 55.3
038-4084 S 038-4075 006 20 0.60 19/0.20 - 3.63 28.98 31.0
038-4085 S 038-4076 010 18 0.95 19/0.25 - 4.21 42.57 19.6
038-4086 S 038-4077 012 16 1.35 19/0.29 - 4.53 54.74 14.9
-
5/26/2018 W&C Sec 7 Issue 5
45/680745
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore Screened Equipment Wire & Cable600 V 135C or 150C
Application
For use as general airframe wires and cables, incorporating unique properties and construction for that purpose e.g. thin-wall,
lightweight etc.
Specifications
In accordance with DEF STAN 61-12 Part 33
Supplement 001
Conductors: Stranded tin or silver plated copperconductors in accordance with BS EN 2083
Insulation: Extruded XLETFE (cross-linked ETFE) for
Type 2 cores Core Identification:
Single-Core - white
Two Core - red, blue
Three Core - red, blue, yellow
Four Core - red, blue, yellow, green
Tin or silver plated copper wire braid screen: 85%
minimum coverage
Outer Sheath: White extruded XLETFE (cross-linked ETFE)
Flame retardant to DEF STAN 61-12 Part 0, clauses 13.39
and 13.40. (10 second flame application)
Temperature Rating: 135C or 150C max conductoroperating temperature as indicated, -55C for low
temperature applications
Voltage Rating: 600 Vrms
-
5/26/2018 W&C Sec 7 Issue 5
46/680746
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore Screened Equipment Wire & Cable600 V 135C or 150C
AnixterPartNumberA10DW-
Cond Type N.S.N.6145-99-
CondSizeCode
NominalCondArea
AWG
NominalCondArea
mm2
NominalCondStranding
#/mm
BraidWireSize
mm
MinO/D
mm
MaxO/D
mm
ApproxCableWeight
kg/km
Max. d.c.ConductorResistance@20C
ohms/km
Single-Core, 135C Rated, Screened & Jacketed
038-3984 P 038-3984 001 26 0.15 19/0.10 0.11 - 1.79 7.16 149.0
038-3985 P 038-3985 002 24 0.20 19/0.12 0.11 - 1.89 8.31 106.0
038-3986 T 038-3986 004 22 0.35 19/0.15 0.11 - 2.16 10.98 60.0
038-3987 T 038-3987 006 20 0.60 19/0.20 0.11 - 2.40 14.44 33.2
038-3988 T 038-3988 010 18 0.95 19/0.25 0.13 - 2.64 18.71 21.1
038-3989 T 038-3989 012 16 1.35 19/0.29 0.13 - 2.77 22.12 15.8
038-3990 T 038-3990 020 14 1.80 37/0.25 0.13 - 3.40 32.08 10.9
038-3991 T 038-3991 030 12 3.00 37/0.32 0.13 - 3.91 45.28 6.8
Two Core, 135C Rated, Screened & Jacketed
038-3992 P 038-3991 001 26 0.15 19/0.10 0.11 - 2.70 12.12 149.0
038-3993 P 038-3992 002 24 0.20 19/0.12 0.11 - 2.90 14.33 106.0
038-3994 T 038-3993 004 22 0.35 19/0.15 0.11 - 3.42 18.68 60.0
038-3995 T 038-3994 006 20 0.60 19/0.20 0.11 - 3.90 25.86 33.2
038-3996 T 038-3995 010 18 0.95 19/0.25 0.13 - 4.38 33.78 21.1
038-3997 T 038-3996 012 16 1.35 19/0.29 0.13 - 4.64 41.30 15.8
038-3998 T 038-3997 020 14 1.80 37/0.25 0.13 - 5.84 59.93 10.9
038-3999 T 038-3998 030 12 3.00 37/0.32 0.13 - 6.86 84.82 6.8
Three Core, 135C Rated, Screened & Jacketed
038-4000 P 038-4000 001 26 0.15 19/0.10 0.11 - 2.84 15.65 149.0
038-4001 P 038-4001 002 24 0.20 19/0.12 0.11 - 3.06 18.76 106.0
038-4002 T 038-4002 004 22 0.35 19/0.15 0.11 - 3.62 24.85 60.0
038-4003 T 038-4003 006 20 0.60 19/0.20 0.11 - 4.14 35.12 33.2
038-4004 T 038-4004 010 18 0.95 19/0.25 0.13 - 4.66 46.55 21.1
038-4005 T 038-4005 012 16 1.35 19/0.29 0.13 - 4.94 57.35 15.8038-4006 T 038-4006 020 14 1.80 37/0.25 0.13 - 6.23 83.38 10.9
038-4007 T 038-4007 030 12 3.00 37/0.32 0.13 - 7.33 120.41 6.8
Single-Core, 150C Rated, Screened & Jacketed
038-4122 P 038-4048 001 26 0.15 19/0.10 0.11 - 1.90 7.81 149.0
038-4123 P 038-4049 002 24 0.20 19/0.12 0.11 - 2.06 9.51 106.0
038-4124 S 038-4050 004 22 0.35 19/0.15 0.11 - 2.16 10.98 55.3
038-4125 S 038-4051 006 20 0.60 19/0.20 0.11 - 2.40 14.66 31.0
038-4126 S 038-4052 010 18 0.95 19/0.25 0.13 - 2.65 19.00 19.6
038-4127 S 038-4053 012 16 1.35 19/0.29 0.13 - 2.79 22.74 14.9038-4128 S 038-4054 020 14 1.80 37/0.25 0.13 - 3.40 32.08 10.2
038-4129 S 038-4055 030 12 3.00 37/0.32 0.13 - 3.91 45.28 6.4
-
5/26/2018 W&C Sec 7 Issue 5
47/680747
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Single-Core & Multicore Screened Equipment Wire & Cable
AnixterPartNumberA10DW-
Cond Type N.S.N.6145-99-
CondSizeCode
NominalCondArea
AWG
NominalCondArea
mm2
NominalCondStranding
#/mm
BraidWireSize
mm
MinO/D
mm
MaxO/D
mm
ApproxCableWeight
kg/km
Max. d.c.ConductorResistance@20C
ohms/km
Two Core, 150C Rated, Screened & Jacketed
038-4130 P 038-4130 001 26 0.15 19/0.10 0.11 - 2.90 13.15 149.0
038-4131 P 038-4131 002 24 0.20 19/0.12 0.11 - 3.22 16.34 106.0
038-4132 S 038-4132 004 22 0.35 19/0.15 0.11 - 3.42 19.42 55.3
038-4133 S 038-4133 006 20 0.60 19/0.20 0.11 - 3.90 26.65 31.0
038-4134 S 038-4134 010 18 0.95 19/0.25 0.13 - 4.42 35.19 19.6
038-4135 S 038-4135 012 16 1.35 19/0.29 0.13 - 4.69 42.65 14.9
Three Core, 150C Rated, Screened & Jacketed
038-4138 P 038-4138 001 26 0.15 19/0.10 0.11 - 3.06 17.02 149.0
038-4139 P 038-4139 002 24 0.20 19/0.12 0.11 - 3.41 21.42 106.0
038-4140 S 038-4140 004 22 0.35 19/0.15 0.11 - 3.62 25.85 55.3
038-4141 S 038-4141 006 20 0.60 19/0.20 0.11 - 4.14 36.18 31.0
038-4142 S 038-4142 010 18 0.95 19/0.25 0.13 - 4.70 48.40 19.6
038-4143 S 038-4143 012 16 1.35 19/0.29 0.13 - 5.00 59.28 14.9
Four Core, 150C Rated, Screened & Jacketed
038-4146 P 038-4146 001 26 0.15 19/0.10 0.11 - 3.32 20.96 149.0
038-4147 P 038-4147 002 24 0.20 19/0.12 0.11 - 3.71 26.64 106.0
038-4148 S 038-4148 004 22 0.35 19/0.15 0.11 - 3.95 32.37 55.3
038-4149 S 038-4149 006 20 0.60 19/0.20 0.11 - 4.53 45.82 31.0
038-4150 S 038-4150 010 18 0.95 19/0.25 0.13 - 5.15 61.78 19.6
038-4151 S 038-4151 012 16 1.35 19/0.29 0.13 - 5.49 76.10 14.9
600 V 135C or 150C
P = silver plated high strength copper alloy (SPHSCA)
T = tin plated copper
S = silver plated copper
-
5/26/2018 W&C Sec 7 Issue 5
48/680748
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Technical Informationfor DEF 61-12 Part 33 Supplement 001 Wires & Cables
Resistance to Fluids
Test Fluid Specification TemperatureFuels Aviation turbine
Kerosene
Gasoline
DEF STAN 91-91
DEF STAN 91-87
ISO 1817 Liquid F
ISO 1817 Liquid B
70C +/- 2C
70C +/- 2C
70C +/- 2C
40C +/- 2C
Lubricating oils Mineral based
Ester based (synthetic)
SAE J 1899 Grade 50
ISO 1817 Liquid 101
100C +/- 5C
150C +/- 5C
De-icing and antifreeze fluids Kilfrost ABC DTD 900/4907 AL34Nato S-1746
50C +/- 2C
Sullage 4 0.1% formaldehyde plus1 0.1% Cresylic acid (mixed
isomers general purpose reagent )
and 95% water
23C +/- 2C1 + 0.1%Cresylic acid (mixed isomersgeneral purpose reagent )
and 95% waterSalt water 3.5% NaCl 50C +/- 2C
De-ionised water 50C +/- 2C
Hydraulic fluids Mineral based DEF STAN 91-48 50C +/- 2C70C +/- 2C
Phosphate ester DTD 900/4881D 100C +/- 5C
Based (synthetic) ISO 1817 Liquid 103 70C +/- 2C
Silicone based OX50 (Nato H-536) 150C +/- 5C
DEF STAN 91-46 70C +/- 2C
Dimethyl silicone, 10 mm2/s (CST)
at 25C
(EX NATO S1714)
Non mineral based (synthetic) 80% 2- Ethoxyethanol 100C +/- 5C
(Ethylene Glycol Monoethyl Ether)
to BS2713 and 20% Castor Oil to
BS7207 by volume
Silicate ester based (synthetic) Oronite M2V 100C +/- 5C
Solvents and cleaning fluids Propan-2-ol (isopropyl alcohol) BS1595 50C +/- 2C
Detergent cleaning fluid minimum MIL-C-43616 20C +/- 2C
pH 10
-
5/26/2018 W&C Sec 7 Issue 5
49/680749
-
5/26/2018 W&C Sec 7 Issue 5
50/680750
Products. Technology. Services. Delivered Globally.
anixter.com
Military Vessels
Application
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in HMsurface ships and submarines. Incorporates LFH (Limited Fire Hazard) insulation and sheathed for reduced levels of smoke and
toxic fumes in the event of a fire. Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids
and water are present.
Specifications
In accordance with DEF61-12 part 25
Conductor: Stranded Class 2 tinned copper conductorsto BS EN 60228
Insulation:Thin-wall LFH (Limited Fire Hazard) insulationto DEF61-12 part 25
N.B. Cores comply with DEF61-12 part 18 for category 1
equipment wires
Core Identification:2 core - red, blue
3 core - red, blue, white
Above three core - Red and blue marker cores adjacent in
each layer with remaining cores white
N.B. When a single-core is used as a centre the colour
shall be white. In addition, cables of four core and above
will also be numbered, in a contrasting colour, the core
colours remaining as detailed above
Binder Tape: p.e.t.p. tape minimum 20% overlap
Outer