Page 1
TRACT D
668,184 SF
15.34 AC
TRACT C
5,364 SF
0.12 AC
C
O
C
O
C
O
C
O
N
* * *B
YC
OM
ME
NT
RE
V. D
AT
E
SCALE:
DATE:
PROJECT NO:
CAD ID: fruitarv-lighting.dwg
~SHEET~
V R
TEX
ENGI
NEER
ING,
INC.
CONS
TRUC
TION
MAN
AGER
S & SI
TE P
LANN
ERS
PROJ
ECT M
ANAG
ERS
CIVI
L & C
ONSU
LTIN
G EN
GINE
ERS
2394 Patterson Road, Suite 201
Grand Junction, CO 81505
Phone: (970) 245-9051
Fax (970) 245-7639
Co
py
rig
ht ©
20
17
, b
y V
orte
x
En
gin
ee
rin
g, In
c. A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
he
site
d
esig
n /
building design and content of this
draw
in
g is cop
yrigh
ted
und
er th
e
Federal C
opyright Law
of 1976. A
ll
rig
hts
a
re
re
se
rv
ed
b
y V
orte
x
Eng
ine
erin
g, Inc., w
ho retain
the
exclu
sive
rig
ht to
th
e d
esig
n o
r
re
-u
se
o
f th
is d
ra
win
g. A
ny u
se
,
re
-u
se
, re
pro
du
ctio
n o
r o
th
er
publication of this draw
ing w
ithout
th
e w
ritte
n c
on
se
nt o
f V
orte
x
En
gin
ee
rin
g, In
c. is p
ro
hib
ite
d.
PROFESSIONAL ENGINEER
COLORADO LICENSE No. 18828
James C.
Atkinson
Frui
ta R
V R
esor
t1
23
5 G
ree
nw
ay
Dri
ve
Fru
ita
, C
olo
rad
o
Lig
htin
g Pl
an
F16-051
10/16/17
1" = 50'
C8.0
FO
R R
EV
IEW
- N
OT
FO
R C
ON
ST
RU
CT
ION
BENCHMARK:
ACCEPTED FOR CONSTRUCTION FOR ONE YEAR FROM THIS DATE
A A
LIGHT POLE DETAIL
SEC. A-A
NTS
NTS
YARD LIGHTING CONTROL:
1. YARD LIGHT FIXTURES SHALL BE OPERATED USING
CONTACTOR(S) CONTROLLED FROM ONE BUILDING
MOUNTED PHOTOCELL FOR AUTOMATIC DUSK TO DAWN
OPERATION. PROVIDE A PHOTOCELL BYPASS SWITCH TO
ALLOW MANUAL OPERATION.
LIGHTING CONTRACTOR NOTE:
1. PRIOR TO ORDERING ANY LIGHTING RELATED ITEMS -
CONTRACTOR MUST VERIFY / ESTABLISH EXISTING
AVAILABLE FACILITIES AND ADJUST ACCORDINGLY.
2. IN ORDER TO COMPLY WITH LOCAL ORDINANCES, THE
CONTRACTOR SHALL ADJUST LIGHT FIXTURES TO MINIMIZE
THE POTENTIAL FOR GLARE AND UNNECESSARY DIFFUSION
OF LIGHT ON TO ADJACENT PROPERTIES OR INTO PUBLIC
RIGHT-OF-WAYS.
LIGHTING PLAN NOTE:
1. THIS PLAN IS INTENDED TO DEPICT PROPOSED LIGHTING
CONDITIONS IN THE NEW PARKING AREAS ONLY. THE
EXISTING WALL POLE LIGHTS ARE SHOWN WITH ASSUMED
WATTAGE. UPGRADES MAY BE NECESSARY. ADDITIONAL
HORIZONTAL INFORMATION IS FOR REFERENCE ONLY AND
THE CONTRACTOR MUST VERIFY ALL INFORMATION WITH
THE APPROVED DESIGN DRAWINGS.
LIGHTING PLAN
AutoCAD SHX Text
EX. WOOD SHED
AutoCAD SHX Text
EX. TRAILER HOUSE
AutoCAD SHX Text
LITTLE SALT
AutoCAD SHX Text
TAX ID # 2697-181-00-071 6.92± ACRES
AutoCAD SHX Text
EX-SSMH-COF1 RIM ELEV=4484.25 INV IN=4474.17(SE) INV IN=4474.17(N) INV IN=4474.17(NE) INV OUT=4473.97(W)
AutoCAD SHX Text
GENERAL PHOTOMETRIC SCHEDULE
AutoCAD SHX Text
AVERAGE FOOTCANDLES
AutoCAD SHX Text
MAXIMUM FOOTCANDLES
AutoCAD SHX Text
MINIMUM FOOTCANDLES
AutoCAD SHX Text
MINIMUM TO MAXIMUM FC RATIO
AutoCAD SHX Text
MAXIMUM TO MINIMUM FC RATIO
AutoCAD SHX Text
12.28 / 0
AutoCAD SHX Text
AVERAGE TO MINIMUM FC RATIO
AutoCAD SHX Text
0.38 / 0
AutoCAD SHX Text
LUMINAIRE SCHEDULE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
(1) LED, Nichia 4000K 70 CRI
AutoCAD SHX Text
KAD LED, 60 LED, 1 AMP MVOLT DRIVER, 4000K, TYPE 3 OPTICS WITH HOUSE SIDE SHIELDS.
AutoCAD SHX Text
ELECTRONIC
AutoCAD SHX Text
Lithonia Lighting, KAD LED 60C 1000 40K R3 MVOLT HS
AutoCAD SHX Text
480V 2P 2W
AutoCAD SHX Text
(1) LED, 2700K
AutoCAD SHX Text
WST LED, Performance package 1, 2700 K, visual comfort forward throw, HVOLT, vandal guard
AutoCAD SHX Text
ELECTRONIC
AutoCAD SHX Text
Lithonia Lighting, WST LED P1 27K VF HVOLT VG
AutoCAD SHX Text
480V 2P 2W
AutoCAD SHX Text
(1) LED, 3000K
AutoCAD SHX Text
WST LED, Performance package 1, 3000 K, visual comfort forward throw, HVOLT
AutoCAD SHX Text
ELECTRONIC
AutoCAD SHX Text
Lithonia Lighting, WST LED P1 30K VF HVOLT
AutoCAD SHX Text
480V 2P 2W
AutoCAD SHX Text
(1) LED, 5000K
AutoCAD SHX Text
WST LED, Performance package 1, 5000K, visual comfort forward throw, HVOLT
AutoCAD SHX Text
ELECTRONIC
AutoCAD SHX Text
Lithonia Lighting, WST LED P1 50K VF HVOLT
AutoCAD SHX Text
480V 2P 2W
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
1" = 50'
AutoCAD SHX Text
20' TRAIL/PEDESTRIAN EASEMENT
AutoCAD SHX Text
PROJECT BENCHMARK IS LOCATED AT THE SOUTHEAST CORNER OF THE PROJECT, IS THE EAST 1/4 CORNER OF SECTION 18, TOWNSHIP 1 NORTH, RANGE 2 WEST OF THE UTE MERIDIAN. THE ELEVATION USED 4495.07 (NAVD88), IS BASED ON MESA COUNTY DEPARTMENT OF PUBLIC WORKS SURVEY INFORMATION MANAGEMENT SYSTEM DATA SHEET GPS ID NO: S223
AutoCAD SHX Text
CITY OF FRUITA ENGINEERING DIVISION REPRESENTATIVE
AutoCAD SHX Text
ACCEPTANCE OF THESE PLANS DOES NOT RELIEVE THE DEVELOPER, CONTRACTOR, OR THE ENGINEER FROM CONFORMANCE WITH THE CITY OF FRUITA DESIGN CRITERIA AND CONSTRUCTION SPECIFICATIONS MANUAL.
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
0'-0 "12"
AutoCAD SHX Text
3" CLEAR
AutoCAD SHX Text
0'-0 "12"
AutoCAD SHX Text
3" CLEAR
AutoCAD SHX Text
1-1/4" AB
AutoCAD SHX Text
LUNIMAIRE AS SPECIFIED
AutoCAD SHX Text
ALUMINUM POLE 6063-T6 TAPERED PLUMB W/ LEVELING NUTS
AutoCAD SHX Text
1-1/4" x42" ANCHORBOLTS W/ DOUBLE NUTS
AutoCAD SHX Text
FLUSH HANDHOLE & COVER
AutoCAD SHX Text
3500 PSI CONCRETE
AutoCAD SHX Text
#4 TIES @ 12" O.C.
AutoCAD SHX Text
#6 VERTICAL