Digital pulse laser power supply touch screen
operation instructionBeijing BOAO laser Tech. Co. Ltd
Address : Room 1201, Building 2, Yard 1, Shangdi International Pioneer Park, 7th
Street ,Shangdi, Haidian District,Beijing, 100085, China
Tel:0086-10-82895905 Fax:0086-10-82895922
Touch screen pulse control power introduction
This power supply consist upper computer touch screen and lower computer pulse
power supply panel of two parts,the parameters of the pulse control power stored in
memory in touch screen,total of 100 set of discharge parameters.Lower position
machine uses 32-bit ARM series CPU quickly implement pulse power control,current
control precision can reach 0.1 A, the power more stable. Touch screen page has 11pages, 1st and 2nd page are mainly used to display manufacturer information, 2nd
page stay 10s after , enter the monitor page automatically, if want to immediately
enter the monitor in the second boot page , you can stay on page 2, press the touch
screen anywhere, can enter the page of monitoring. Monitoring, parameter, light and
other pages can press the corresponding button, switch to each other.
Page switching diagram:
Technical index1.Control current: 40A-300A2.Pulse width:0.1ms-20ms
1st
open machine page
2nd
open machine page
Monitoring Parameter Light spot other
IO input test SettingChange langueIO output test
Cleared timegas valve delayChoose xenon lamp
-
8/12/2019 Touch Screen Manual
2/15
3.Laser frequence:0.1Hz-100Hz 0HZ is inching. Each grade 1Hz
4.Power output frequence 6KW
5.Work environment : input power triphase 220V10%,Use it at the environment
temperature below 30 and dry condition , airborne dust
-
8/12/2019 Touch Screen Manual
3/15
1:The whole interface top left is current time ,middle is the name the interface,
right is current date,middle left is information of machine work,include the alarm
message .
Alarm message prompt include not open machine ,use time limit, the firefailure,
charging test fault,no hydraulic pressure, over current, Overheating, over-voltage,
generatrix charging test, firesignal test,Conduction time is more than the cycle
time,close the machine,LEM1 the signal wire break,LEM2 the signal wire
break,power too big, work normally.
2: Middle right is the communication information,the below is the xenon lamp
choice,have Single lamp 1,Single lamp 2 and Double lamp
3:Left bottom show each parameter ,if need change the parameter you can enter the
page of change parameter page,right is the name of each interface,
press can start power high pressure make power work normally
if press show the below window
Press OK can close the power high pressure,wait 1 minute then can close the main
power, cannt press OK then close the power immediately,press the cancel can cancel
the window.
-
8/12/2019 Touch Screen Manual
4/15
press the button can enter the interface modification
parameter page, as below:
Mainly used to edit various parameters of the discharge parameters number,
setup program also established a correspondent name,can determine a product need
parameters more convenient and fast, A program number corresponds to a set of
parameters, you want to increase the segments number of discharge ,first set up the
the segments of discharge,then show the corresponding discharge parameters input
box. After change the current parameter,need to press save parameter to save the
current the current parameters.
show parameter number, can via the button jump out of the
corresponding parameters of discharge parameters.
each parameter have a corresponding name, show this group of process
parameters corresponding to the product name. Can show by English and spell
The discharge frequency of current parameters
Customers according to their own product material feature to set of the
discharge parameters ,can set arbitrary waveforms in order to achieve welding effect,
Choose one at the normal case, if increase or decrease segments of discharge,must
change the data first,then can show the corresponding segments input box
-
8/12/2019 Touch Screen Manual
5/15
The current discharge parameters are saved to the memory button
This one can adjust the motor torque, Generally used for the optical path of the beam
expander automatic adjustment, Its minimum is 0.1, the maximum can be adjusted to
3.0, at the motor set,the numerator and denominator of the electronic gear ratio is
directly related to the motor in the above beam adjustment box ,the size of the rotation
distance adjust 0.1.
The larger the ratio adjusting 0.1 every time ,the motor shaft the greater
distance.Users can setting up the ideal molecular denominator parameters according
to themself needed.
-
8/12/2019 Touch Screen Manual
6/15
In this page you can look at updated version of touch screen and the control panel,can
be used interchange both English and Chinese, and the single Point Compensation,the
test of signal input and output,the button of set,
There are :foot switch,over current,overheating,water press signal test,when there is
no signal input red light will not change,the red light will be red, green, alternate flash
when have signal ,Here we can detect the external input signal whether have foot
-
8/12/2019 Touch Screen Manual
7/15
switch , overheating, the water pressure. over current, parameters of we use now, 1, 2,
3, 4, can be ignored if dont use.
On this page you can see the entire sequence of operation of the machine,and the good
and bad of the control panel,Run led signal light will display whether normal
communication between panel and touch screen,Light spot direction : Light spot
motor drive signal quality,if display green light when input and charge denote the
machine high pressure have started and signal have be sent out, Fire 1.2.3.4 We only
use the two-way at double lamp the Fire1 and fire2 will have a signal output, If it is
single light just the fire1 have the signal output,gas valve and Shutter,We can see
whether the signal output until depress the foot switch. Buzzer:it will Chirping and
red light flicker when the machine break down
-
8/12/2019 Touch Screen Manual
8/15
This provide clients with a single lamp repair function, now widespread in front of a
few relatively strong power, in the case of low frequency can be improved, if the front
of points is strong , you can adjust small the percent of the front points,if certain point
need stronger you can adjust the percent big.
Total pointsis the number of points of need to marking a products, at the frequency
lower case ,
Single point total multiples: if 14 points are not enough, you can use this
function,such as 2 times is 28 points, can be adjusted
Product time interval:the time interval after you finished the first products to mark
the second product.
-
8/12/2019 Touch Screen Manual
9/15
This page include 3 parts
1: Reset times : press this button can make the times of monitor page change to zero.
The machine begin recounts at next work start
2: Set the gas valve delay ,press the foot switch the gas valve open immediately, after
delay gas valve delaycorresponding time,the laser will output.After loose the foot
switch, laser stop to output , after the delay set time , gas valve close.
3: single lamp 1. single lamp 2
Double lamp change-over button, if the single lamp power cannt be changed ,just can
use the single lamp 1.
In other pages blank key long press 3 seconds, a dialog box will appear
-
8/12/2019 Touch Screen Manual
10/15
Manufacture set password,the default password is 0 ,press OK enter the page of input
limited
-
8/12/2019 Touch Screen Manual
11/15
In this page customers can change the parameter of the current, frequency, pulse
width to make the machine reasonable use.
The installment plan
You can set three stages password on this page, you can set a password at every
stages,you should notice the data setup , the time of last stage must smaller than the
later stage,
manufacture set password: can set the manufacture input password,The default
password is 0
-
8/12/2019 Touch Screen Manual
12/15
Supper password :It is a universal password, you use this password when forget other
password.
Prompt day number:This is the first phase of the password from time to set the
number of days If the password does not be relieved , every day have the prompt:
If the time has finished ,not unlock password, program will automatically stop
working ,just input the password for this issue will be released can be used normally.
Finish these set ,choose the Period of use passwordthen press the OK,the set is
successful
Control panel connector
1:Shutter directly from the on-board terminal A1 1,2 feet drawn two lines to the
Shutter is ok, no external power supply.
2: Drive motor can lead to 5V pulse and direction from the A2 directly to the driver is
OK, drive only connect 24V power supply ok, dont worry COM. 5V is cited from the
board to the drive
-
8/12/2019 Touch Screen Manual
13/15
A1 is the power input end of Motherboard, A2 is the data lines of connecting to touch
screenA3 connect the Shutter,just connect 12V and GATE ok. A4 connect the drive
motor, 5V PLUSDIR is ok, Adjustable light spot motor torque , A5A6 connect
drive signal, A7, A8 connect sensor signal.if is the single lamp power drive signal just
connect A5 , Sensor signal only connect A7.
IO board connection port
To touch screen
Shutter Drive
Drive signal
Motherboard
Sensor signal
(2,3,5 foot)
Empty
Empty
Empty
Empty
-
8/12/2019 Touch Screen Manual
14/15
IO board,B1 connect the signal output end ,B2 connect the control of the remote
end,B3 connect the signal input end
Wiring method of the single lamp power supply
IO board
Gas valve
Fire2
Fire 1
Charge 1
Main
input
Remote-
sensingcontrol area
Empty
Empty
Empty
Empty
Data down
Cursor down
Cursor up
Data up
foot
Heat protection
Pressure protection
-
8/12/2019 Touch Screen Manual
15/15
stop start
Pressure protection Footempty
Gas valve
220V
FanFan
Fan
Xenon lamp
stop
220V
Interface