AmericaBy Harvey Kaylie,President,Mini-Circuits, Inc.
Everyone is
talking about thedecline of the American economy,
the loss of jobs, and poor prospectsgoing forward. Instead of talking
about political issues, I propose adifferent approach to this problem.
Weve lost sight of the fact that
America was built on creativity,determination, hard work, and the
opportunity to employ thesequalities to achieve success. Read
More...
But I was looking
for just a phone.By Barry Manz
If you need proofthat the end of the
plain old mobile
phone is near, juststop by your local
Verizon store. There,if you're in a wealthy area, you'll find
walls full of smartphones and tablets, 4G
mobile hotspots, and lots of accessories.Search long enough and you'll find asingle shelf on which perhaps three
feature phones will be displayed. If you
visit a Verizon store in a less affluentarea, you'll find about twice as many
feature phones and fewer smart phones.
Read More...
September 2011
Previous issues click here
Click here for Military Products
How to Specify RF and
Microwave Filters
Covers cavity, ceramic, LC, crystaland helical filters.
Anatech Electronics
Establishing An RF Safety
Program
Topics include basic RF safety,standards, monitoring instruments,
performing an emitter inventory,
and the steps required to create aprogram.
Narda Safety Test Solutions
Mounting Considerations for
Medium Pow er Surface-Mount
RF DevicesCovers all factors that must be
considered when mounting SMTdevices.
TriQuint Semiconductor
Article Submission Requirements Product Submission Requirements
Display Advertising Rates Advertising Guidelines Mechanical Requirements Special Supplements Editorial Calendar Download Media Kit (PDF)
IN MY OPINION
FROM WHERE WE SIT
CURRENT ISSUE PRODUCTS
Low Phase Noise
VC O
Model SMV1365C-LF in
L-band is a VCO that
operates from 1265 to
1465 MHz with a
tuning voltage range of 0.5 to 4.5 Vdc. It
features a typical phase noise of -98 dBc/Hz
@ 10 K Hz offset and a t ypical tuning
sensitivity of 113 MHz/V. It is available in tapeand reel packaging.
Z-Communications
Presentation
Switcher
The Enova
DVX-3150HD
all-in-one
presentation switcher
features advanced technology for end-to-end
distribution of HDMI signals with full HDCP
with the simplicity of analog and without
interruption or key constraints using
InstaGate Pro technology.
AMX
Coaxial Precision
Fixed Attenuator
Model
BW-S1-2W 263+, ideal
for matching,
April 2008
Accurate High RF Power MeasurementBy Jin Yu and Henry Szczurko, Berkeley Varitronics Systems, Inc.
Abstract
Accurate measurement of base station transmission power is necessary to provide good covera
ge to the desired area and not to interfere with other cells using the same frequency. The
accuracy requirement of transmission power level is typically 10%, which is equal to 0.4 dB.
Usually a base station transmits signals at power levels about 40 Watts. However, both thermalpower meters and spectrum analyzers cannot handle high power. The use of test equipment with
the addition of couplers and attenuators will easily introduce other errors to the measurement and
thus reduce the accuracy. The Yellow Frog 2 is the latest power meter from Berkeley Varitronics
Systems which can be connected directly to base station and measure up to 50 dBm (100 Watts);the accuracy is about 0.25 dB.
Accurate Base Station Measurement
Measuring base station transmission power is very important when installing and monitoringwireless networks. Usually a survey study is implemented to validate and predict RF coverage forthe cell. The transmission power should be constant during a site survey. When RF coverage is
validated and the base stations are installed, the output power is verified by the system
engineers. The base station transmission power is expected to cover the area inside the cell andnot to interfere with other cells. A lower transmission power will cause poor coverage at the edge
of the cell and a higher power will transmit the signals to other cells and cause interference if
same frequency is used at those cells. Therefore, the accurate control of base station transmitterpower has an impact on the overall system performance. The transmission power levels typically
have a total accuracy requirement of 10%, which is about 0.4 dB [1].
Thermal Power Meters and Other Test Equipment
A traditional base station has a transmission power level about 40 Watts (43 dBm). Most of thethermal meters on the market can only measure up to 20 dBm. Therefore, a thermal meter must
be used with couplers or attenuators to measure the base station transmission power.
Considering the losses and variations of couplings, this setup can introduce considerablemeasurement errors if not properly calibrated. Another drawback of a thermal power meter is that
the power heads are easily damaged after being dropped from the top of an equipment rack [1].
SEARCH MPDS EXTENSIVE
DATABASE!
You Can
Search by Number:
All ads, articles, and pro ducts in printed
issues of MPD have a number. Just look
for the red arrow in the ad or at the
end of the article or prod uct
description.
- - - - - OR - - - - -
Search by Keyword, Company,Category or Issue.
The MPD database has more than 250
articles, 3,000 product descriptions, and
ads from our advertisers from 2007 to
the current issue.
MILITARY MICROWAVE DIGEST
WHITE PAPERS
Accurate High RF Power Measurement http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Defau
of 5 10/12/2011 9:57PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.pdffactory.com/http://www.pdffactory.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asp -
8/3/2019 Tai Lieu Huong Dan May Yellow Frog 2
2/5
Biasing MMIC Amplifiers
How to bias MMICs along withtheory and techniques.
Mini-Circuits
Radar Measurements
Topics include fundamentals,measurements, radar cross section,
and antenna measurements.
Agilent Technologies
Multi-Link Point-to Point
Protocol (MLPPP) in theEvolving Radio Access Netw ork
Examines MLPPP within radio access
networks (RAN, quality of service innetwork architectures to support
new services.
Freescale Semiconductor
A guide to designing for ESD
and EMCIncludes ESD pulses, passive
component behavior over
frequency, PCB layout techniques,and more.
NXP Semiconductors
instrumentation and
test set-ups, covers the DC to 26 GHz
frequency range. Features include precise
attenuation, excellent VSWR (1.09 typ.), and
stainless steel N male and female connectors.
Input power is 2W.
Mini-Circuits
Magnetron
Transmitter
Model 337 Power
MOSFET Modulator,
Magnetron
Transmitter, is
designed to operate
magnetrons up to 500
kW. The continuouslyvariable pulse width
range is 0.15 to 2.0 microseconds or greater
at PRF up to 5 kHz. Maximum pulse width is
determined by the pulse storage capacitor
value and the magnetron capability.
Applied Systems Engineering
See all products in this issue
HMC-T2270
A spectrum analyzer can also be used to measure the power. However, there are several things
which make it difficult to use spectrum analyzers to measure base station transmission power.First, spectrum analyzers are geneally more expensive than power meters. Secondly, the absolute
power measurement accuracy of a spectrum analyzer is typically about 1dB to 1.5dB (a 41%
error) although, that being said, spectrum analyzers have excellent relative power measurementcapabilities. Power-handling capacity is another issue for spectrum analyzers. Many spectrum
analyzers cannot handle several watts of power. It means the combined use with coupler and
attenuator will further reduce the measurement accuracy.
BVS Yellow Frog 2 Power Meter
Yellow Frog 2 is Berkeleys latest handheld power meter product. There are two models for thisproduct. The first model is made for frequencies ranging from 700 MHz to 2.7 GHz and for power
ranging from 0 dBm (0.001 Watts) to 50 dBm (100 Watts). The second model extends the
frequency range of the first model. It can also measure frequencies from 150 MHz to 700 MHz inwhich the power can be measured from 10 dBm to 50 dBm. The Yellow Frog 2 has a resolution of
0.1 dB, an accuracy of 0.5 dB, and a maximum input voltage standing wave ratio (VSWR) of
1.20. In a practical test or measurement, the accuracy for most of the frequencies is within 0.25dB. The temperature range of compensation is from 0 to 50C. The specifications of the Yellow
Frog 2 are shown in Table 1.
The Yellow Frog 2 can operate continuously for over 8 hours using an internal Lithium Polymer
battery. A discharged battery can be fully charged in less than 3 hours using the built-in fast
charger and external 12 VDC power supply. The portable instrument weighs less than 2 poundsand dimensionally fits in the palm of your hand (3"H 3"W 5"L). The unit features a large LCD
display and USB port which also provides power when connected to any PC running Windows XP
or Vista operating systems. While the Yellow Frog 2 includes PC controller/monitoring software forsetting frequencies and recording power out, it does not require a PC to operate. Additional
accessories include N-type adapters, 6-ft. long USB cable, and optional 20W or 40 W 50 load.
Figure 1 shows a Yellow Frog 2 and the application software.
AMTA 2011
Accurate High RF Power Measurement http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Defau
of 5 10/12/2011 9:57PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.pdffactory.com/http://www.pdffactory.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asp -
8/3/2019 Tai Lieu Huong Dan May Yellow Frog 2
3/5
The Yellow Frog 2 is able to measure RF power from CW as well as more complex signals, such
as GSM, CDMA, and WiMAX over the 50 dB dynamic range. Using one or two Yellow Frog 2units, engineers can easily measure VSWR at the base of the antenna or load. It can be
connected directly to Gator, Dragon, Lizard or any transmitter with a standard type Nconnector for instant verification of wired power levels in dBm or Watts. The direct connectionreduces the errors caused by the combined use with couplers and attenuators.
Power Measurement
There are two parameters that determine the exact transmission power to an antenna. One is the
input power to the antenna; another is the VSWR, which represents how much power is reflectedby the antenna. How to measure these two parameters is addressed in the following text.
CW Signal Measurement
Typically, a site survey study is used to validate RF coverage. Usually a CW transmitter is set at
the position of base station and then CW receivers are moved around to measure and recordreceived power levels. The measurement data will be mapped to the survey area to validate and
predict the RF coverage. Monitoring the transmission power level is extremely important at thisstage because varying transmission power would cause erroneous coverage validation. The
Yellow Frog 2 can also record the power levels by using the supplied application software.Berkeley Varitronics Systems (BVS) provides a complete package for drive study and propagation
analysis, including Gator transmitter, Yellow Frog 2 power meter, Coyote modular receiver,Forecaster mapping software, and Sieve 40 conversion software.
Figure 2a shows how to measure the transmission power. In this instance, the Yellow Frog 2 isconnected to the antenna directly. This reduces the uncertainties in measuring the final
transmission power from the antenna. The Yellow Frog 2 can show both dBm and Watts on the
screen and updates 4 times per second.
Modulated Signal Measurement
When a base station transmits modulated signals, the modulation factor or crest factor of thewaveforms should be known for the measurement. The Yellow Frog 2 power meter fundamentally
responds to voltage and not to power. A direct consequence of this characteristic is that inputsignals of equal Root Mean Square (RMS) power but different crest factors will produce different
Accurate High RF Power Measurement http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Defau
of 5 10/12/2011 9:57PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.pdffactory.com/http://www.pdffactory.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asp -
8/3/2019 Tai Lieu Huong Dan May Yellow Frog 2
4/5
results at the output. The effect of modulation is to shift the readings up or down. However, the
shift is not affected when the modulation format is fixed. For example, comparing a sine wave and
single CDMA channel of the same RMS power, the Yellow Frog 2 power meter will differ by theequivalent of 3.55 dB over the complete dynamic range of the device (the output for a CDMA input
being lower). Table 2 shows the correction factors that should be applied to measure the RMS
signal strength of various signal types. A sine wave input is used as a reference. To measure theRMS power of a square wave, for example, the shift 3.01 dB should be subtracted from the
reading. Therefore, it is necessary to load the modulation factor into the unit to accuratelymeasure the power level of modulated signals.
VSWR Measurement: Measurement with One UnitIn Figure 2, if the antenna is not matched well to the Yellow Frog 2 unit (50 ), the antenna will
reflect the input power to the transmitter and the output power level will be lower than that shownon the screen of the unit. It is necessary to know the VSWR parameters to calculate the exact
transmission power from the antenna. When only one Yellow Frog is at hand, we can do it in the
following steps:
1. Set up the parameters in the unit, such as frequency, modulation factor and so on.
2. Connect the devices as shown in Figure 2a and read the data on the screen. Assume it is p1
and p1 = 30 dBm.
3. Reverse the Yellow Frog 2 unit and then read the data on the screen again. Assume it is p2 andp2 = 10 dBm.
4. Calculate the VSWR by using Equation 1. Note here p1 and p2 are in dBm and they have to be
converted to Watts to do the calculation in Equation 1. In this example, VSWR = 1.22. The plot of
VSWR versus p2/p1 is shown in Figure 3.
From Equation 1, we can express p1 in terms of p2 and VSWR,
Since Yellow Frog 2 can measure down to 0 dBm from 700 - 2700 MHz and 10 dBm from 150-700MHz, the curves in Figure 4 show the minimum requirements of p1 to be able to measure VSWR
for 0 dBm and 10 dBm.
Measurement with Two Units
If there are two Yellow Frog 2 units available, they can be used jointly to measure the VSWR.
Connect these two units as shown in Figure 2b and then replace it with the unit in Figure 2a.Similarly, we have two readings from the two units. The reading of the first unit is p1, which
represents the input power level. The reading of the unit connected to the antenna is p2, which isthe reflection power from the antenna. The VSWR can be calculated using Equation 1.
Accurate High RF Power Measurement http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Defau
of 5 10/12/2011 9:57PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.pdffactory.com/http://www.pdffactory.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asp -
8/3/2019 Tai Lieu Huong Dan May Yellow Frog 2
5/5
ConclusionAccurate measurement of base station transmission power is necessary to install and maintain
wireless cellular networks. Yellow Frog 2 power meter, which is a new product from Berkeley
Varitronics Systems, provides the solution to measure high RF transmission power (up to 100Watts) with high accuracy.
Reference
[1] Bill Rau, Power Meter Parameters, http://telephonyonline.com/wireless/mag/
wireless_power_meterparameters/, Aug. 1998.
Berkeley Varitronics Systemswww.bvsystems.com
TXTLINX.COM 102
Email this article to a friend!
Home | About Us | Archives | Editorial Submissions | Media Kit (PDF) | Events | Subscribe/Renew | Contact Us
Copyright 2011 Octagon Communication Inc. DBA MPDigest / MPDigest.com, All Rights Reserved.
Privacy Policy| Site Map
Accurate High RF Power Measurement http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Defau
of 5 10/12/2011 9:57PDF created with pdfFactory Pro trial version www.pdffactory.com
http://telephonyonline.com/wireless/mag/http://www.bvsystems.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.pdffactory.com/http://www.pdffactory.com/http://www.mpdigest.com/issue/Articles/2008/Apr/berkeley/Default.asphttp://www.bvsystems.com/http://telephonyonline.com/wireless/mag/