WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
Operating Vibration Test Report
Issue by
Design Quality Department
Report No: 1709VO1487
Product 8” M101BK VESA Mount(M101BK)
Model
Product VESA Mount
Description
■New product
■VESA Mount
Renew product
PCB :
BIOS:
Revision change
PCB :
Test
BIOS:
Component:
Reason
2017/09/08 John Lin Rick Huang
Issue date Approved Test Engineer
1
WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
1. Document Introduction
This document describes how we conduct the environment conditions and test procedure. It
includes the test equipment we use, the test condition, and the test procedure we take. We also
define our test criteria and the way to conclude the test result.
(According to client’s test specification, please see following sheets in detail.) Table of Testing Summary Results NO Test Item Condition Description Sect. Reference
/ Page to
1 Vibration Test Operation
4
MIL-STD-810G
Random vibration: 5 Hz ~ 500 Hz
/ 5
Method 514.6
Impact acceleration:
1.48 & 1.90 & 2.24 g rms Procedure I
Axis of vibration: Figure 514.6C-3
Transverse-X, Longitudinal-Y, Vertical-Z
Duration time: each axis 60 min.
2
WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
2. Product Configuration
1. M/B:M101BK-100
2. CPU:Intel Celeron [email protected] (2.16GHz) 7.5W
3. RAM:ADATA ADDS1600W8G11-BMIP 204p 1.35V DDR3L-1600 8GB
4. SSD:Innodisk DEM24-B56M41BCADC M.2 SSD 2242 256GB
5. BIOS/EC:101BKV003 / 101BK003
6. Panel:ONation OT080ZBWDMN-00 1280X800 750Nits
7. Touch:NanoBit NBT0801701-10 80%/1.60mm
8. WiFi +BT:Intel Dual Band Wireless-AC 3165
9. Camera:Fangtec AV3950A22-SJ-4A0 5M
10. GPS:u-blox NEO-M8U
11. Adapter:EDAC EA10633B AC:100-240V~1.5A 50-60Hz DC:19V 3.42A
12. Battery:JHT M101 2S2P 7.4V 10280 mAh
2S1P Photo of VESA Mount
3
WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
3. Photo of Product Configuration
Photo of EUT
Top View Bottom View
Front View Back View
Right Side View Left Side View
4
WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
4. Vibration Test (Operating)
A. Test Equipment: ─Vibration Tester: King Design / EM-600F2K-50N120 (S/N: BT103176796)
─Controller: Dactron Photon PH-100 RT-PRO (S/N: 4750143)
─Control Accelerometer: B&K 4398A (S/N: 2169071)
B. LAB Environmental Conditions: ─Ambient Temperature: 25 +/- 3℃ ─Relative Humidity: 55 +/- 20% RH
C. Test Method / Specification: ─Compliance of MIL-STD-810G/Method 514.6/Procedure I / Figure 514.6C-3
─Operation
─Random vibration: 5 Hz ~ 500 Hz ─Impact acceleration: 1.48 & 1.90 & 2.24 g rms ─Axis of vibration: Transverse-X, Longitudinal-Y, Vertical-
Z ─Duration time: each axis 60 min.
─Total Time: 3 hours
─Quantity: Total 1 Set
─Testing Period: Aug. 18, 2017 to Aug. 18, 2017
D. Check Condition and Requirements: Place the product on the vibration table in its normal operating orientation and
configuration. The Product shall be no fixture to the vibration table such that the vibratory input is
transmitted directly to the product. Operating the product during the test. Vibrate the product up
the frequency range at a rate of 5 to 500 Hz. At the appropriate level in the table of test condition
in each of three orthogonal axes. The test shall last approximately 60 minutes per axis.
Equivalent to 1.48 & 1.90 & 2.24 g. Document the result during the test. The functional and
electrical check is required; document the result after the check.
5
WinMate Inc. 9F, No. 111-6 Hsing Teh Road,
San-Chung, Taipei, Taiwan, R.O.C www.winmate.com.tw TEL :886-2-6635-5758
FAX:886-2-6635-5859
E. Test Result: ─No visible damage to the product. ─No displacement of components, cables, or hardware. ─The exterior container must not be broken exposing the contents. ─The
test unit operates normally after the completion of the vibration test.
Appearance of specimen Functional check
F. Test Judgment: ─Test Result as below:
Check Item Appearance check
(Visual check) Functional
& Performance
check
Style Item No.
Initial
Final
8” M101BK VESA
No visible damage
No visible damage
Normal
Mount(M101BK)
7