Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST stek GESTEK Gestek GESTE tek GESTEK Gestek GESTEK ek GESTEK Gestek GESTEK k GESTEK Gestek GESTEK GESTEK Gestek GESTEK Certificate of Test March 2008 GesTek EMC Lab N0. 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. TEL:886-2-2603-5321 FAX:886-2-2603-5325 WinMate Communications INC. Product Type : 8.4” Multimedia LCD Touch Monitor Model Number : R08T230-RMT1/TR/IT/R Brand Name : WinMate Test Report Number : 0803068E-01 Date of Test : March 21, 2008 This Product was tested to the following standards at the laboratory of Global EMC Standard Tech. Corp., and found Compliance. Standards: EN 55022: 2006, Class B EN 55024: 1998 + A1: 2001 + A2: 2003, IEC 61000-4 Series EN 61000-3-2: 2006 & EN 61000-3-3: 1995 + A1: 2001 + A2: 2005 Sharon Chang, President Date: March 28, 2008 http : //www.gestek.com.tw NVLAP LAB CODE 200085-0

Upload: others

Post on 19-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

Certificate

Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST stek GESTEK Gestek GESTE tek GESTEK Gestek GESTEK ek GESTEK Gestek GESTEK k GESTEK Gestek GESTEK GESTEK Gestek GESTEK

Certificate of Test March 2008

GesTek EMC Lab N0. 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. TEL:886-2-2603-5321 FAX:886-2-2603-5325

WinMate Communications INC.

Product Type : 8.4” Multimedia LCD Touch Monitor Model Number : R08T230-RMT1/TR/IT/R Brand Name : WinMate Test Report Number : 0803068E-01 Date of Test : March 21, 2008 This Product was tested to the following standards at the laboratory of Global EMC Standard Tech. Corp., and found Compliance. Standards: EN 55022: 2006, Class B EN 55024: 1998 + A1: 2001 + A2: 2003, IEC 61000-4 Series EN 61000-3-2: 2006 & EN 61000-3-3: 1995 + A1: 2001 + A2: 2005

Sharon Chang, President

Date: March 28, 2008

http : //www.gestek.com.tw

NVLAP LAB CODE 200085-0

Page 2: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

Declaration of Conformity

We, Manufacturer/Importer (full address)

declare that the product

( description of the apparatus, system, installation to which it refers)

EUT: 8.4” Multimedia LCD Touch Monitor

Model Number: R08T230-RMT1/TR/IT/R

is in conformity with

(reference to the specification under which conformity is declared) in accordance with 2004/108/EC-EMC Directive

EN 55011 Limits and methods of measurement EN 61000-3-2 Disturbances in supply systems caused

of radio disturbance characteristics of industrial, scientific and medical (ISM) EN 61000-3-3 Disturbances in supply systems caused high frequency equipment by household appliances and similar electrical equipment “Voltage fluctuations”

EN 55013 Limits and methods of measurement Information Technology EN 55024 Information Technology of radio disturbance characteristics of equipment-Immunity broadcast receivers and associated characteristics-Limits and methods of equipment measurement

EN 55014-1 Limits and methods of measurement EN 61000-6-1 Generic standards-Immunity for of radio disturbance characteristics of residential, commercial and light-industrial household electrical appliances, environments portable tools and similar electrical apparatus EN 61000-6-2 Generic standards-Immunity for industrial environments

EN 61000-6-3 Generic standards-Emission standard for residential, commercial and light-industrial EN 55014-2 Immunity requirements for household environments appliances tools and similar apparatus

EN 61000-6-4 Generic standards-Emission standard for EN 50091- 2 EMC requirements for uninterruptible industrial environments power systems (UPS)

EN 55015 Limits and methods of measurement EN 55020 Immunity from radio interference of of radio disturbance characteristics of broadcast receivers and associated fluorescent lamps and luminaries equipment

EN 55022 Limits and methods of measurement EN 61204-3 Low voltage power supplies, d.c. output - of radio disturbance characteristics of Part 3: Electromagnetic compatibility. (EMC) information technology equipment

DIN VDE 0855 Cabled distribution systems; Equipment EN 62040-2 EMC requirements for uninterruptable power systems (UPS)

part 10 for receiving and/or distribution from part 12 sound and television signals

CE marking (EC conformity marking)

The manufacturer also declares the conformity of above mentioned product with the actual required safety standards in accordance with LVD 73/23 EEC

EN 60065 Safety requirements for mains operated EN 60950 Safety for information technology equipment

electronic and related apparatus for including electrical business equipment household and similar general use

EN 60335 Safety of household and similar EN 50091-1 General and Safety requirements for electrical appliances uninterruptible power systems (UPS)

Manufacturer/Importer

Signature: (Stamp) Date: Name:

Page 3: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.: 0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 1 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

European Union [EU] EMC Directive [2004/108/EC, As Amended]

EMC Test Report For:

WinMate Communications INC.

EUT: 8.4” Multimedia LCD Touch Monitor

Model Number:

R08T230-RMT1/TR/IT/R

Prepared for: WinMate Communications INC.

9F, No. 111-6, Shing-De Rd., San-Chung City, Taipei 241, Taiwan, R.O.C.

Report By : Global EMC Standard Tech. Corp. No.3 Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel : 886-2-2603-5321 Fax: 886-2-2603-5325

Test results given in this report only relate to the specimen(s) tested, measured. This report is the property of GesTek, and shall not be reproduced, other than in full, without the written consent of GesTek. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. All data in this report are traceable to national standard or international standard.

Page 4: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.: 0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 2 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

TABLE OF CONTENTS Description Page 1. CERTIFICATION 3 2. SUMMARY OF TEST RESULTS 4 3. GENERAL INFORMATION 5

3.1 PRODUCT DESCRIPTION 5 3.2 TEST MODES & EUT COMPONENTS DESCRIPTION 5 3.3 CONFIGURATION OF THE SYSTEM UNDER TEST 6 3.4 BLOCK DIAGRAM OF CONNECTIONS BETWEEN EUT AND

SIMULATORS 7 3.5 TEST FACILITY 8

4. CONDUCTED EMISSION MEASUREMENT 9 4.1 TEST EQUIPMENTS 9 4.2 TEST METHOD 9 4.3 BLOCK DIAGRAM OF TEST SETUP 9 4.4 CONDUCTED EMISSION LIMITS 10 4.5 EUT CONFIGURATION ON MEASUREMENT 10 4.6 CONDUCTED EMISSION DATA 10 4.7 OPERATING CONDITIONS OF THE EUT 10 4.8 CONDUCTED EMISSION MEASUREMENT RESULTS 11

5. RADIATED EMISSION MEASUREMENT 13 5.1 TEST EQUIPMENT 13 5.2 TEST METHOD 13 5.3 OPEN AREA TEST SITE & ANECHOIC CHAMBER SETUP

DIAGRAM 13 5.4 RADIATED EMISSION LIMITS 14 5.5 EUT CONFIGURATION 14 5.6 OPERATING CONDITIONS OF THE EUT 14 5.7 RADIATED EMISSION DATA 14 5.8 RADIATED EMISSIONS MEASUREMENT RESULTS 15

6. HARMONIC CURRENT EMISSIONS, VOLTAGE FLUCTUATIONS AND FLICKER MEASUREMENT 17

6.1 TEST EQUIPMENT 17 6.2 TEST METHOD 17 6.3 BLOCK DIAGRAM OF TEST SETUP 17 6.4 LIMITS OF FLICKER MEASUREMENT 18 6.5 OPERATING CONDITIONS OF THE EUT 18 6.6 TEST PROCEDURE 18 6.7 TEST RESULT 18

7. ESD IMMUNITY TEST 20 7.1 TEST EQUIPMENT 20 7.2 TEST METHOD 20 7.3 BLOCK DIAGRAM OF TEST SETUP 20 7.4 SEVERITY LEVELS 21 7.5 OPERATING CONDITIONS OF THE EUT 21 7.6 TEST PROCEDURE 21 7.7 TEST RESULT 22

8. RF FIELD STRENGTH SUSCEPTIBILITY TEST 23 8.1 TEST EQUIPMENT 23 8.2 TEST METHOD 23 8.3 BLOCK DIAGRAM OF TEST SETUP 23 8.4 SEVERITY LEVELS 24 8.5 OPERATING CONDITIONS OF THE EUT 24 8.6 TEST PROCEDURE 24 8.7 TEST RESULT 25

9. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST26

9.1 TEST EQUIPMENT 26 9.2 TEST METHOD 26 9.3 BLOCK DIAGRAM OF TEST SETUP 26 9.4 SEVERITY LEVELS 27 9.5 OPERATING CONDITIONS OF THE EUT 27 9.6 TEST RESULT 28

10. SURGE IMMUNITY TEST 29 10.1 TEST EQUIPMENT 29 10.2 TEST METHOD 29 10.3 BLOCK DIAGRAM OF TEST SETUP 29 10.4 SEVERITY LEVELS 29 10.5 OPERATING CONDITIONS OF THE EUT 30 10.6 TEST PROCEDURE 30 10.7 TEST RESULT 31

11. CONDUCTED DISTURBANCE SUSCEPTIBILITY TEST 32 11.1 TEST EQUIPMENT 32 11.2 TEST METHOD 32 11.3 BLOCK DIAGRAM OF TEST SETUP 32 11.4 SEVERITY LEVELS 32 11.5 OPERATING CONDITIONS OF THE EUT 33 11.6 TEST PROCEDURE 33 11.7 TEST RESULT 34

12. MAGNETIC FIELD IMMUNITY MEASUREMENT 35 12.1 TEST EQUIPMENT 35 12.2 TEST METHOD 35 12.3 BLOCK DIAGRAM OF TEST SETUP 35 12.4 SEVERITY LEVELS 36 12.5 EUT OPERATION CONDITION 36 12.6 TEST PROCEDURE 36 12.7 TEST RESULT 36

13. VOLTAGE DIPS AND SHORT INTERRUPTIONS TEST 37 13.1 TEST EQUIPMENT 37 13.2 TEST METHOD 37 13.3 BLOCK DIAGRAM OF TEST SETUP 37 13.4 SEVERITY LEVELS 37 13.5 OPERATING CONDITIONS OF THE EUT 37 13.6 TEST PROCEDURE 37 13.7 TEST RESULT 38

14. PHOTOGRAPHS FOR TEST 39 14.1 TEST PHOTOGRAPHS FOR CONDUCTION 39 14.2 TEST PHOTOGRAPHS FOR RADIATED 40 14.3 TEST PHOTOGRAPHS FOR HARMONIC/FLICKER 41 14.4 TEST PHOTOGRAPHS FOR ESD 42 14.5 TEST PHOTOGRAPHS FOR ESD TEST POINTS 43 14.6 TEST PHOTOGRAPHS FOR RS 45 14.7 TEST PHOTOGRAPHS FOR EFT 46 14.8 TEST PHOTOGRAPHS FOR SURGE 47 14.9 TEST PHOTOGRAPHS FOR CS 48 14.10 TEST PHOTOGRAPHS FOR MAGNETIC 49 14.11 TEST PHOTOGRAPHS FOR DIPS 50

15. PHOTOGRAPHS FOR PRODUCT 51 16. EMI/EMS REDUCTION METHOD DURING COMPLIANCE

TESTING 55

Page 5: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 3 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

1. CERTIFICATION

Applicant : WinMate Communications INC. EUT Description : 8.4” Multimedia LCD Touch Monitor Model Number : R08T230-RMT1/TR/IT/R Brand Name : WinMate Serial Number : N/A

MEASUREMENT PROCEDURES USED: EN 55022: 2006 AND

EN 61000-3-2: 2006 & EN 61000-3-3: 1995 + A1: 2001 + A2: 2005 EN 55024: 1998 + A1: 2001 + A2: 2003 AND IEC 61000-4 SERIES REGULATIONS

For EN 55022: 2006: The measurements shown in the attachment were made in accordance with the procedures indicated, and the maximum emissions from the equipment were found to be within the applicable EN 55022: 2006 limits.

For EN 55024: 1998 + A1: 2001 + A2: 2003: The measurement results are contained in this test report and show that the EUT to be technically compliant with the EN 55024: 1998 + A1: 2001 + A2: 2003 Immunity regulations.

GENERAL REMARKS: The tests were performed according to the technical requirement of EUT.

Electro-magnetic Radiated Emission Interference Measurement (EN 55022) Electro-magnetic Conducted Emission Interference Measurement (EN 55022) Harmonic Current Emissions (EN 61000-3-2) Voltage Fluctuation and Flicker Measurement (EN 61000-3-3) ESD Immunity Test (IEC 61000-4-2) RF Field strength Susceptibility Test (IEC 61000-4-3) Electrical Fast Transient/Burst Immunity Test (IEC 61000-4-4) Surge Immunity Test (IEC 61000-4-5) Conducted disturbance Susceptibility Test (IEC 61000-4-6) Low Frequency Signals Immunity Test (IEC 1000-2-2) Power Frequency Magnetic Field Immunity Test (IEC 61000-4-8) Voltage Dips/Short Interruptions Test (IEC 61000-4-11)

Date of Test: March 21, 2008 In order to ensure the quality and accuracy of this document, the contents have been thoroughly reviewed by the following qualified personnel from GesTek Lab.

Documented By : Tested By: Nico Hsu / adm. Dept.Technical Report Author Nick Hsu / eng. Dept. Engineer

Approved By: Tonny Lin / General Manager

Page 6: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 4 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

2. SUMMARY OF TEST RESULTS

STANDARD TEST ITEM TEST RESULT REMARKS

Conducted emission (Mode 1) PASS

The worst emission frequency is 0.3731 MHz And minimum passing margin is –9.10 dB The measurement uncertainty is 3.6 dB.

EN 55022 Class B

Radiated emission (Mode 1) PASS

The worst emission frequency is 440.1541MHz at Horizontal. And minimum passing margin is –5.52 dB. Height of antenna is 2.87 M. Angle of turntable is 2°. The measurement uncertainty is 5.1 dB.

EN 61000-3-2: 2006 Harmonic Current Emissions PASS

With regards to the EN 61000-3-2, the EUT must be tested at full load in order to reach the assigned current of the Power supply. With Dummy Load Active Power > 75W (Note: EUT power level is below 75 Watts and therefore has no defined limits) The measurement uncertainty is 3.0 mA

EN 61000-3-3: 1995 + A1: 2001 + A2: 2005

Voltage Fluctuation and Flicker Measurement PASS The Value of Pst shall not be greater than 1.0

The measurement uncertainty under consideration

EN 55024 IEC 61000-4-2: 1995 + A1: 1998 + A2: 2000

Electrostatic Discharge(ESD) PASS

Contact discharge up to ±4kV Air discharge up to ±8kV . The measurement uncertainty is 50.6%

EN 55024 IEC 61000-4-3: 2002 +

A1: 2002

RF field strength Susceptibility PASS

80-1000MHz (1kHz sinewave with 80% Amplitude Modulation: 3V/m) The measurement uncertainty is 1.50dB

EN 55024 IEC 61000-4-4: 2004

Electrical Fast Transients/Burst PASS ±0.5kV, ±1.0kV (AC Input)

The measurement uncertainty is 55.2%

EN 55024 IEC 61000-4-5: 1995 +

A1: 2000 Surge PASS ±0.5kV, ±1kV, ±2kV (AC Input)

The measurement uncertainty is 55%

EN 55024 IEC 61000-4-6: 2003 +

A1: 2004

Conducted Disturbance Susceptibility PASS

0.15-80MHz (1kHz sinewave with 80% Amplitude Modulation: 3V) The measurement uncertainty is 2.03dB

EN 55024 IEC 61000-4-8: 1993 +

A1: 2000

Magnetic Field Measurement PASS 1A at 50Hz

The measurement uncertainty is 9.22%

Voltage short Interruptions >95% reduction, 5s

EN 55024 IEC 61000-4-11: 2004

Voltage Dips PASS >95% reduction, 10 ms

30% reduction, 500 ms The measurement uncertainty is 6.8%

Page 7: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 5 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

3. GENERAL INFORMATION 3.1 PRODUCT DESCRIPTION

Product Name : 8.4” Multimedia LCD Touch Monitor Model Number : R08T230-RMT1/TR/IT/R Brand Name : WinMate Serial Number : N/A Applicant : WinMate Communications INC. Address : 9F, No. 111-6, Shing-De Rd., San-Chung City, Taipei 241, Taiwan,

R.O.C. Manufacturer : WinMate Communications INC. Address : 9F, No. 111-6, Shing-De Rd., San-Chung City, Taipei 241, Taiwan,

R.O.C. Power Supply : AC Input: 100~240V/50~60Hz, DC Output: 12~17V, 4.2A Power Cord : AC Input: 3Pins, 1.8m, Non-Shielded, detachable

DC Output: 1.8m , Non-Shielded, with Core 3.2 TEST MODES & EUT COMPONENTS DESCRIPTION

Note: 1. According to pre-scan data, we determine the data shown(Mode 1) in this test report, which

reflects the worst-case data for each operation mode.

EUT: 8.4” Multimedia LCD Touch Monitor, M/N: R08T230-RMT1/TR/IT/R

Test Mode Mode 1- VGA

800 x 600, 60Hz (Test Mode)

Mode 2- AV (Pre-scan Mode)

Mode 3- S-Video (Pre-scan Mode)

Adaptor EDAC, M/N: EA1050C-120

VGA Cable 1.8m , Shielded, with Core*2

AC Power Cable 3Pins, 1.8m , Non-Shielded, detachable

Page 8: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 6 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

3.3 CONFIGURATION OF THE SYSTEM UNDER TEST

Device No. Configuration

PS2 Mouse M02-401

Manufacturer : detrois Model Number : CanMouse CM-309 Serial Number : N/A BSMI ID : R63159 FCC ID : N/A

Data Cable : Shielded, Undetachable, 1.5m

PS2 Keyboard K01-049

Manufacturer : ACER Model Number : 6311-TA Serial Number : 99P208104C09N20385S0000 BSMI ID : 3882A039 FCC ID : N/A

Data Cable : Shielded, Undetachable, 1.5 m

DVD PLAYER D01-024

Manufacturer : TOSHIBA Model Number : SD-K860SU AC INPUT :120V~60Hz,13W Power Cord : Non-Shielded, Detachable, 2Pin, 1.8m

Printer P01-018

Manufacturer : Hewlett Packard Model Number : 2225C Serial Number : 2548S40842 BSMI ID : 3892A957 FCC ID : BS46XU2225C

Data Cable : Shielded, Detachable, 1.2m, Parallel Cable Power Cord : Non-Shielded, Detachable, 1.8m

Far End Network Server

-----

Mother Board : ASUS, M/N: TUSL2-C F.D.D. : Panasonic, M/N: JU-257A606P H.D.D. : Seagate, M/N: ST330621A CD-ROM : MITSUMI, M/N: CRMC-FX4830T VGA : On Board Sound : On Board LAN : On Board SDRAM : 32MB PC100 CPU : Intel,733M/133MHz S. P. S. : DELTA, M/N: DTPS-200PB-109C Power Cord : Non-Shielded, Detachable, 1.8m

Page 9: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 7 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

Device No. Configuration

Model Number : Pavilion a000 BSMI ID : R33001 Serial Number : TWL410000F C.P.U : AMD Athlon XP 2400+ DDR : infineon PC2700 256M *2 DDR333 FDD : MITSUMI M/N:D353M3D

BSMI ID:D63119 H.D.D. : Manufacturer :SAMSUNG

M/N:SV041IN 40G BSMI ID:D33475

DVD-ROM : Manufacturer :PHILIPS M/N:DR0M6016/4A BSMI ID:D43002

Mother Board : ASUS M/N:A7V8X-LA BSMI ID:D33005

PC System HP PC06

S.P.S

: HIPRO M/N:HP-D2537F3H Input:100-127V /6 A , 200-240V/ 4A 47~63 Hz Output:+5V/22A,-12V/0.8A,+12V/14A,+3.3V/18A +5VSB/2A BSMI ID:D33036

3.4 BLOCK DIAGRAM OF CONNECTIONS BETWEEN EUT AND SIMULATORS

VGA

RS232S-Video AV

PS2 Mouse

PS2 Keyboard

Far End Network ServerLAN Cable

Printer DVD Player

P.C. EUT: 8.4” Multimedia LCD Touch Monitor

Adaptor

Page 10: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 8 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

3.5 TEST FACILITY

Items Requirement Temperature (°C) 10-40 Humidity (%RH) 10-90

Barometric pressure (mbar)

860-1060

Site Description : Accreditation on NVLAP effective through September 30, 2008. For CISPR 22, FCC Method and AS/NZS CISPR 22 Measurement. NVLAP Lab Code: 200085-0 Registration on VCCI effective through July 02, 2010. Recognized by the Council of Taiwan Accreditation Foundation As an accredited laboratory and registration No.:1082. Registration on TAF effective through September 19, 2009. Name of firm : Global EMC Standard Tech. Corp. Site location : No. 3 Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.

NVLAP LAB CODE 200085-0

Page 11: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 9 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

4. CONDUCTED EMISSION MEASUREMENT 4.1 TEST EQUIPMENTS

Item Instrument Manufacturer Model Serial No. Next Cal. Date1 Test Receiver R & S ESCS30 825022/003 2008.05.25 2 L.I.S.N. (EUT) R & S ENV216 100006 2008.05.28 3 L.I.S.N.(AE) ROLF HEINE NNB-2/16Z 98091 2008.07.22 4 RF CABLE GTK N/A GTK-E-A149-01 2008.09.06 5 50 Ohm Terminator GTK N/A GTK-E-A130-01 N/A 6 Shielded Room GTK N/A B5 N/A

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

4.2 TEST METHOD According to EN 55022: 2006

4.3 BLOCK DIAGRAM OF TEST SETUP 4.3.1 TEST SETUP FOR EMISSION MEASUREMENT AT MAINS TERMINAL Metal Ground Plane

80cm

40cm Load

Non-conducted table

L.I.S.N. (EUT)

EUT

Test Receiver

Transformer/ Convertor

80cm

Filter(EUT)

Filter(AE)

L.I.S.N.(AE)

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

Page 12: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 10 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

4.4 CONDUCTED EMISSION LIMITS

4.4.1 CONDUCTED EMISSION LIMITS (MAINS TERMINAL)

Maximum RF Line Voltage dB(μV) Frequency

Class A Class B

MHz QUASI-PEAK AVERAGE QUASI-PEAK AVERAGE

0.15 to 0.50 79 66 66 to 56 56 to 46

0.50 to 5.0 73 60 56 46

5.0 to 30 73 60 60 50

Remarks: In the Above Table, the tighter limit applies at the band edges. 4.5 EUT CONFIGURATION ON MEASUREMENT

The equipments, which are listed at 4.1, are installed on Conducted Emission Test to meet the Commission requirement and operating in a manner which tends to maximize its emission characteristics in a normal application. The device under test, installed in a representative system as described in section 4.3.1, was placed on a non-conductive table whose total height equaled 80 cm. The EUT was powered through one L.I.S.N. whose the signal output was terminated to the receiver. The other peripherals were powered from another L.I.S.N. whose the signal output was terminated by 50 Ohms terminator.

4.6 CONDUCTED EMISSION DATA

The measurement range of conducted emission, which is from 0.15 MHz to 30 MHz, was investigated. The initial step in collecting conducted data is a spectrum analyzer peak scan of the measurement range for all the test modes. Then the worst modes were reported the following data pages. The final measurement equal to Receiver reading plus a Correction factor when AMN insertion loss bigger than 0.5dB, the receiver added the correction factor to the reading level automatically.

4.7 OPERATING CONDITIONS OF THE EUT

The exercise program used during conducted emission measurement was designed to exercise the EUT in a manner similar to a typical use. The exercise sequence is listed as below: 1. Setup the EUT and simulators as shown on 4.3. 2. Turn on the power of all equipments. 3. Boot the P.C. from Hard Disk and setup the video to Windows XP, active all devices. 4. Connect the Far End Network Server and run test program “test.bat “. 5. Adjust to appropriate video resolution. 6. Active other internal devices such as network function. 7. Run “WINRFI” test program under Windows XP. 8. P.C. sent “H” pattern to monitor, make the “H” pattern full in the screen. 9. P.C. sent “H” pattern to parallel and serial port. 10. Repeat above steps.

Page 13: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 11 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

4.8 CONDUCTED EMISSION MEASUREMENT RESULTS

Date of Test March 21, 2008 Temperature 26 ℃ EUT 8.4” Multimedia LCD

Touch Monitor Humidity 60 %

Test Mode Mode 1 Display Pattern H Pattern Test Power Supply AC 230V/50Hz

Line

No. Frequency MHz

Reading Level dBμV

FactordB

MeasurementdBμV

Limit dBμV

Over Limit dB Detector

1 0.1574 29.29 9.63 38.92 65.60 -26.68 QP 2 0.1574 3.65 9.63 13.28 55.60 -42.32 AVG 3 0.1912 38.24 9.63 47.87 63.98 -16.11 QP 4 0.1912 31.13 9.63 40.76 53.98 -13.22 AVG 5 0.2485 36.04 9.64 45.68 61.81 -16.13 QP 6 0.2485 32.59 9.64 42.23 51.81 -9.58 AVG 7 0.3731 30.84 9.64 40.48 58.43 -17.95 QP 8 ★0.3731 29.69 9.64 39.33 48.43 -9.10 AVG 9 2.9029 27.07 9.66 36.73 56.00 -19.27 QP

10 2.9029 19.46 9.66 29.12 46.00 -16.88 AVG 11 3.5198 29.18 9.65 38.83 56.00 -17.17 QP 12 3.5198 20.58 9.65 30.23 46.00 -15.77 AVG

Remarks : 1. All readings are Quasi-peak and Average values. 2. Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation). 3. Over Limit (Margin Value)=Measurement level-Limit value. 4. Factor = L.I.S.N. insertion loss + cable loss 5. “ ★ ” means that this data is the worse case measurement level. 6. The measurement uncertainty is 3.6 dB.

Line

Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.

Page 14: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 12 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

Date of Test March 21, 2008 Temperature 26 ℃ EUT 8.4” Multimedia LCD

Touch Monitor Humidity 60 %

Test Mode Mode 1 Display Pattern H Pattern Test Power Supply AC 230V/50Hz

Neutral

No. Frequency MHz

Reading Level dBμV

FactordB

MeasurementdBμV

Limit dBμV

Over Limit dB Detector

1 0.1537 29.41 9.63 39.04 65.80 -26.76 QP 2 0.1537 6.33 9.63 15.96 55.80 -39.84 AVG 3 0.1868 39.40 9.63 49.03 64.18 -15.15 QP 4 0.1868 30.11 9.63 39.74 54.18 -14.44 AVG 5 0.2475 36.69 9.64 46.33 61.84 -15.51 QP 6 0.2475 31.45 9.64 41.09 51.84 -10.75 AVG 7 0.3708 30.74 9.64 40.38 58.48 -18.10 QP 8 ★0.3708 29.15 9.64 38.79 48.48 -9.69 AVG 9 2.9628 24.67 9.66 34.33 56.00 -21.67 QP

10 2.9628 21.13 9.66 30.79 46.00 -15.21 AVG 11 3.8902 25.95 9.65 35.60 56.00 -20.40 QP 12 3.8902 18.15 9.65 27.80 46.00 -18.20 AVG

Remarks : 1. All readings are Quasi-peak and Average values. 2. Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation). 3. Over Limit (Margin Value)=Measurement level-Limit value. 4. Factor = L.I.S.N. insertion loss + cable loss 5. “ ★ ” means that this data is the worse case measurement level. 6. The measurement uncertainty is 3.6 dB.

Neutral

Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.

Page 15: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 13 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

5. RADIATED EMISSION MEASUREMENT 5.1 TEST EQUIPMENT

The following test equipments are used during the radiated emission tests: Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 TEST RECEIVER R & S ESCS30 825022/003 2008.05.25 2 SPECTRUM RS FSL6 100517 2008.06.13 3 PRE-AMPLIFIER HP 8447D 2944A08610 2008.09.09 4 BILOG Antenna SCHAFFNER CBL6112B 2833 2008.11.22 5 Cable GTK N/A GTK-E-A150-01 2008.12.13 6 Open Site GTK N/A A2 2008.07.04

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

5.2 TEST METHOD According to EN 55022: 2006 Radiated emission measurement was performed at the antenna to EUT distance of 10 meters.

5.3 OPEN AREA TEST SITE & ANECHOIC CHAMBER SETUP DIAGRAM

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

EUT

FRP Dome

Test Receiver

Antenna Mast

TO controllerTo Receiver

Metal Full Soldered Ground Plane

Non-Conductive Table

10m

1m to 4m

80cm

Broadband or Dipole Antenna Antenna height can be moved from 1m to 4m; Antenna and turntable distance 10m

Load

Page 16: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 14 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

5.4 RADIATED EMISSION LIMITS

Class B Limits Frequency Distance Field Strength

MHz Meter dB(μV/m)

30 to 230 10 30

230 to 1000 10 37 Class A Limits

Frequency Distance Field Strength

MHz Meter dB(μV/m)

30 to 230 10 40

230 to 1000 10 47

Remark: 1. The tighter limit shall apply at the edge between two frequency bands.

2. Distance refers to the distance in meters between the measuring antenna and the closest point of any part of the device or system.

5.5 EUT CONFIGURATION

The EUT, which is listed at 3.4, was installed at the Radiated Emission Test site to meet the Commission requirements and operated in a manner, which tends to maximize its emission characteristics in a normal application. The EUT, installed in a representative system as described in section 5.3, was placed on a non-conductive table whose total height equaled 80 cm. This table can be rotated 360 degrees. The measurement antenna was mounted to a non-conductive mast capable of moving the antenna vertically. Antenna height was varied from 1 meter to 4 meters and the system under test was rotated from 0 degree through 360 degrees relative to the antenna position and polarization (Horizontal and Vertical). Also the I/O cable positions were investigated to find the maximum emission condition.

5.6 OPERATING CONDITIONS OF THE EUT Same as conducted emission measurement, which is listed in 4.7

5.7 RADIATED EMISSION DATA The frequency range of radiated emissions from 30 MHz to 1 GHz was investigated. The initial step in collecting emission data was a spectrum analyzer peak scan of the frequency range for all the test modes. Then the worst modes were reported the following data pages.

Page 17: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 15 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

5.8 RADIATED EMISSIONS MEASUREMENT RESULTS

Date of Test March 21, 2008 Temperature 26 deg/C

EUT 8.4” Multimedia LCD Touch Monitor

Humidity 60 %RH

Working Cond. Mode 1 Display Pattern H Pattern Antenna distance 10m at Horizontal Frequency Range 30-1000MHz Test Power Supply AC 230V/50Hz

No. Frequency MHz

Reading Level dBμV

Factor dB

Measurement dBμV/m

Limit dBμV/m

Over LimitdB Detector

1 187.5420 33.54 -13.87 19.67 30.00 -10.33 QP 2 209.3663 34.57 -12.83 21.74 30.00 -8.26 QP 3 361.5471 34.56 -6.52 28.04 37.00 -8.96 QP 4 ★440.1541 36.12 -4.64 31.48 37.00 -5.52 QP 5 470.8440 31.03 -4.02 27.01 37.00 -9.99 QP 6 600.0420 29.42 -1.41 28.01 37.00 -8.99 QP

Remarks: 1. All Readings below 1GHz are Quasi-Peak. 2. Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation). 3. Over Limit (Margin Value)=Measurement level-Limit value. 4. Factor = antenna factor + cable loss – amplifier gain. 5. “ ★ ” means that this data is the worse case measurement level. 6. The measurement uncertainty is 5.1 dB.

Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.

Page 18: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 16 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

Date of Test March 21, 2008 Temperature 26 deg/C

EUT 8.4” Multimedia LCD Touch Monitor

Humidity 60 %RH

Working Cond. Mode 1 Display Pattern H Pattern Antenna distance 10m at Vertical Frequency Range 30-1000MHz Test Power Supply AC 230V/50Hz

No. Frequency MHz

Reading Level dBμV

Factor dB

Measurement dBμV/m

Limit dBμV/m

Over LimitdB Detector

1 115.6730 36.69 -12.59 24.10 30.00 -5.90 QP 2 ★142.3544 37.13 -12.78 24.35 30.00 -5.65 QP 3 361.6421 35.76 -6.52 29.24 37.00 -7.76 QP 4 473.5412 34.38 -3.96 30.42 37.00 -6.58 QP 5 485.3740 32.89 -3.72 29.17 37.00 -7.83 QP 6 834.6510 28.48 2.03 30.51 37.00 -6.49 QP 7 899.4613 26.13 2.95 29.08 37.00 -7.92 QP

Remarks: 1. All Readings below 1GHz are Quasi-Peak. 2. Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation). 3. Over Limit (Margin Value)=Measurement level-Limit value. 4. Factor = antenna factor + cable loss – amplifier gain. 5. “★” means that this data is the worse case measurement level. 6. The measurement uncertainty is 5.1 dB.

Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.

Page 19: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 17 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

6. HARMONIC CURRENT EMISSIONS, VOLTAGE FLUCTUATIONS AND

FLICKER MEASUREMENT 6.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date1 Signal Conditioning Unit SCHAFFNER CCN1000-1 72282 2008.06.04 2 Power Source PACIFIC 345AMX/UPC32 270 2008.12.18 3 SOFTWARE SCHAFFNER WIN2100 V3 N/A N/A 4 Shielding Room GTK N/A B7 N/A

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

6.2 TEST METHOD

According to EN 61000-3-2: 2006 (Note: EUT power level is below 75 Watts and therefore has no defined limits)

EN 61000-3-3: 1995 + A1: 2001 + A2: 2005. 6.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

Power Source

EUT Load

To AC Line

Control Computer Printer

Signal

Conditioning Unit

Shield Room

Non-Conducted Table

Page 20: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 18 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

6.4 LIMITS OF FLICKER MEASUREMENT

Flicker: Limits

Pst 1.0 Plt 0.65 d(t) 3.3%

Time(ms)>dt 500ms dc 3.3%

dmax 4%

6.5 OPERATING CONDITIONS OF THE EUT 1. Setup the EUT and Test Equipment as shown on 6.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test. 6.6 TEST PROCEDURE

6.6.1 Flicker: The test voltage supplied the EUT shall be maintained within 230V±2%. The frequency shall be 50Hz±0.5%. The observation perid Tp: -for Pst Tp=10min. -for Plt Tp=2h.

6.7 TEST RESULT

1. The measurement of the flicker, which test at the extremes of EUT‘s supply range was investigated, and the test result are reported the following data pages. The measurement limits were met, and the EUT passed the test.

2. The measurement uncertainty is 3.0 mA

Page 21: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 19 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

Flicker Test Summary per EN/IEC61000-3-3 (Run time)

EUT: 8.4" Multimedia LCD Touch Monitor Tested by: Nick Test category: All parameters (European limits) Test Margin: 100 Test date: 2008/3/21 Start time: AM 11:06:46 End time: AM 11:17:06 Test duration (min): 10 Data file name: F-000041.cts_data Comment: M/N: R08T230-RMT1/TR/IT/R Customer: WinMate Communications INC. Test Result: Pass Status: Test Completed Psti and limit line European Limits

0.25

0.50

0.75

1.00

Pst

11:17:06

Plt and limit line

0.25

0.50

Plt

11:17:06

Parameter values recorded during the test: Vrms at the end of test (Volt): 228.19 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass

Page 22: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 20 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

7. ESD IMMUNITY TEST 7.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 ESD SIMULATOR SYSTEM EM TEST ESD 30C 0201-03 N/A

2 Shielded Room GTK N/A B4 N/A

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

7.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-2: 1995 + A1: 1998 + A2: 2000

7.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT.

For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

Metal Ground Plane

ESD Simulator

EUT Load

Insulation

AL Plate, Horizontal Coupling Plane

Non-Conducted table

470K ohm Resistors

470K ohm Resistors

AL Plate, Vertical Coupling Plane

80cm

Filter AC

230V/50Hz

AC 110V/60Hz

Filter

Page 23: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 21 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

7.4 SEVERITY LEVELS

Required Performance Criteria : B Level : ±8kV and lower levels (Air Discharge) ±4kV and lower levels (Contact Discharge)

7.5 OPERATING CONDITIONS OF THE EUT 1. Setup the EUT and Test Equipment as shown on 7.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test.

7.6 TEST PROCEDURE Air Discharge:

This test was performed on non-conductive surfaces in accordance with IEC 61000-4-2: 1995 + A1: 1998 + A2: 2000 Single discharge at > 1-second interval, at least 10 positive & 10 negative discharges. Air discharges to surfaces of the EUT.

Contact Discharge: Single discharge at > 1-second interval, at least 25 positive & 25 negative discharges. Horizontal Coupling Plane (HCP) under the EUT & Vertical Coupling Plane (VCP) beside the 4 sides of the EUT, with the sharp discharge electrode touching the coupling plane. HCP discharge: ESD was applied to the earth reference plane on each accessible side of the EUT. VCP discharge: Vertical Coupling Plane was positioned at a distance of 0.1m from the EUT. The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test points.

Page 24: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 22 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

7.7 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 40 % Test Power Supply AC 230V/50Hz

Item Amount of Discharge Voltage Required

Criteria Complied to Criteria (A, B, C)

Result

10 +2kV +4kV +8kV +15kV B A PASSAir Direct

Discharge 10 -2kV -4kV -8kV -15kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSContact Direct

Discharge 25 -2kV -4kV -6kV -8kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSIndirect Discharge

(HCP) 25 -2kV -4kV -6kV -8kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSIndirect

Discharge (VCP) (Front) 25 -2kV -4kV -6kV -8kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSIndirect Discharge

(VCP) (Left) 25 -2kV -4kV -6kV -8kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSIndirect Discharge

(VCP) (Back) 25 -2kV -4kV -6kV -8kV B A PASS

25 +2kV +4kV +6kV +8kV B A PASSIndirect Discharge

(VCP) (Right) 25 -2kV -4kV -6kV -8kV B A PASS

The measurement uncertainty is 50.6% Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test.

★ The green tag means the air discharge point (See the report page 43-44). ★ The red tag means the contact point (See the report page 43-44).

Page 25: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 23 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

8. RF FIELD STRENGTH SUSCEPTIBILITY TEST 8.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 SIGNAL GENERATOR MARCONI 2030 3110196 2008.07.18

2 Power Amplifier A & R 250W1000A 313023 N/A 3 Field Strength Meter A & R FM2000 16837 N/A

4 Ultra Breitband Antenna R & S ULTRALOG HL562 100282 N/A

5 Chamber GesTek N/A B3 2008.03.30

6 EMS Program Software GesTek GTK-E-S001-01

GTK-E-S004-01 N/A N/A

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

8.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-3: 2002 + A1: 2002

8.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

EUTField Sensor

Non-Conducted Table

80cm

3 m

1m

Ferrite Tile Fully-Anechoic Chamber Equiped with Ferrite Tile

Turn Table

Filter

Power Amplifier

Signal Generator

Field Meter

Control Computer

camera system

Camera Monitor

Measurement Room

Antenna mast

Power Supply system convertor

Load

Page 26: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 24 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

8.4 SEVERITY LEVELS

Required Performance Criteria : A Level : 80~1000MHz(1kHz sinewave with 80% Amplitude

Modulation: 3V/m) 8.5 OPERATING CONDITIONS OF THE EUT

1. Setup the EUT and Test Equipment as shown on 8.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test.

8.6 TEST PROCEDURE The EUT and load were placed on a table, which was 0.8 meters high. The field sensor was also placed on the same table to monitor field strength from transmitting antenna. EUT was set 3 meters away from the transmitting antenna. The transmitting antenna was fixed at 1 meter above ground. Both horizontal and vertical polarizations of the antenna were used during testing. In order to judge the EUT performance, a CCD camera was used to monitor the EUT screen. All the scanning conditions are as follows:

Condition of Test Remarks Field Strength 3V/m Radiated Signal 80MHz-1000MHz (1kHz sinewave with 80%

Amplitude Modulation: 3V/m) Frequency step size Δ f : Δ f = f n - f (n-1) =

1Q

f (n -1) Where: Δ f = frequency step size f (n-1) = previous test frequency f n = Next test frequency Q = Ratio center frequency to bandwidth

Page 27: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 25 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

8.7 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 60 % Test Power Supply AC 230V/50Hz

Freq. Range (MHz)

Position (Angle)

Polarity (H or V)

Field Strength (V/m)

Performance Criteria

Complied to Results

0 H / V 3 A PASS

90 H / V 3 A PASS

180 H / V 3 A PASS

26-80 MHz 80-1000 MHz 900 ± 5 MHz

270 H / V 3 A PASS

The measurement uncertainty is 1.50dB Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test.

Page 28: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 26 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

9. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 9.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 ULTRA COMPACT GENERATOR EM TEST UCS 500-M 0500-15 2008.05.07

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

9.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-4: 2004

9.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

EFT/Burst Generator

EUT LoadTo AC

Line

Control Computer Shield Room

Non-Conducted Table

Ground Reference Plane (GRP)

80cm

Ground Plane AC Power Line to EUT

Coupling Clamp

Signal Line

Generator chassis earthed

10cm

Page 29: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 27 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

9.4 SEVERITY LEVELS

Required Performance Criteria : B Level : ±0.5kV, ±1.0kV for Power Lines and protective earth terminal 9.5 OPERATING CONDITIONS OF THE EUT

1. Setup the EUT and Test Equipment as shown on 9.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test.

The EUT and its load were placed on a table which was 0.8 meters above a metal ground plane measuring 2m by 2m and 0.65mm thick min, and projecting beyond the EUT by at least 0.1m on all sides. More then 0.5 meters separated the EUT from the walls of the shielded room.

Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation. The EUT was also monitored during the test for any degradation of performance.

For AC Power lines test:

The EUT is connected to the power mains through a coupling/decoupling network that directly injected the transient energy. Bursts of pulse trains were injected onto the power line, in both positive and negative polarities. The test level was 0.5kV and 1.0kV. The Line, Neutral, and protective earth conductors were impressed with burst noise for one minute.

Page 30: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 28 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

9.6 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 60 % Test Power Supply AC 230V/50Hz

Inject Place: Power Supply Line

Inject Line Polarity Voltage

KV Inject time(minute)

Inject Method

Required Criteria

Complied to Criteria Result

L 1 DIRECT B A PASS N 1 DIRECT B A PASS

PE 1 DIRECT B A PASS L+N 1 DIRECT B A PASS

N+PE 1 DIRECT B A PASS L+PE 1 DIRECT B A PASS

L+N+PE

+ 0.5 1.0 2.0

1 DIRECT B A PASS L 1 DIRECT B A PASS N 1 DIRECT B A PASS

PE 1 DIRECT B A PASS L+N 1 DIRECT B A PASS

N+PE 1 DIRECT B A PASS L+PE 1 DIRECT B A PASS

L+N+PE

- 0.5 1.0 2.0

1 DIRECT B A PASS The measurement uncertainty is 55.2%

Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test. The

acceptance criteria were met, and the EUT passed the test.

Page 31: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 29 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

10. SURGE IMMUNITY TEST 10.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 ULTRA COMPACT GENERATOR EM TEST UCS 500-M 0500-15 2008.05.07

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

10.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-5: 1995 + A1: 2000

10.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same. 10.4 SEVERITY LEVELS

Open Circuit Output Test Voltage +/- 10% Level On power supply lines

1 0.5KV 2 1KV 3 2KV 4 4KV X Special

Surge

Generator

EUT LoadTo AC Line

Control Computer Shield Room

Non-Conducted Table

Ground Reference Plane (GRP)

80cm

Ground Plane AC Power Line to EUT

CDN Signal Line

Generator chassis earthed

10cm i l ti

Page 32: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 30 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

10.5 OPERATING CONDITIONS OF THE EUT

1. Setup the EUT and Test Equipment as shown on 10.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual operation mode during test.

10.6 TEST PROCEDURE

A “combination wave” as specified in IEC 61000-4-5: 1995 + A1: 2000 was applied to the EUT. The amplitude was gradually increased using control software. Surges were initiated line synced. One surge per polarity and voltage level was applied in common and differential mode to the EUT at 0, 90, 180, 270, and 0 degree phase angles. The surges were applied at a rate of 1 surge per minute. The EUT was monitored for any degradation of performance. The AC test was conducted for differential mode at 0.5kV &1.0kV and common mode at 0.5kV &1.0kV & 2.0kV. All tests were run in both the positive and negative polarity for differential and common modes.

Page 33: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 31 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

10.7 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 60 % Test Power Supply AC 230V/50Hz

Inject Line Voltage KV

RepetitionRate

(minute)Phase Angle

Surge applied Method

Number of tests

Required Criteria

Complied to Criteria Result

1 0° Coupling 5 B A PASS1 90° Coupling 5 B A PASS1 180° Coupling 5 B A PASS

+0.5 +1.0

1 270° Coupling 5 B A PASS1 0° Coupling 5 B A PASS1 90° Coupling 5 B A PASS1 180° Coupling 5 B A PASS

L-N Differential mode

-0.5 -1.0

1 270° Coupling 5 B A PASS1 0° Coupling 5 B A PASS1 90° Coupling 5 B B PASS1 180° Coupling 5 B A PASS

+0.5 +1.0 +2.0

1 270° Coupling 5 B A PASS1 0° Coupling 5 B A PASS1 90° Coupling 5 B A PASS1 180° Coupling 5 B A PASS

L-PE Common mode

-0.5 -1.0 -2.0

1 270° Coupling 5 B A PASS1 0° Coupling 5 B A PASS1 90° Coupling 5 B A PASS1 180° Coupling 5 B A PASS

+0.5 +1.0 +2.0

1 270° Coupling 5 B B PASS1 0° Coupling 5 B A PASS1 90° Coupling 5 B A PASS1 180° Coupling 5 B A PASS

N-PE Common mode

-0.5 -1.0 -2.0

1 270° Coupling 5 B A PASS The measurement uncertainty is 55%

Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. The screen would flash during the test, but not interference it was return to normal by itself.

(at +2k L-P +90° and +2k N-P +270°) No false alarms or other malfunctions were observed during or after the test. The

acceptance criteria were met, and the EUT passed the test.

Page 34: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 32 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

11. CONDUCTED DISTURBANCE SUSCEPTIBILITY TEST 11.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 Continuous Wave

Simulator EM TEST CWS 500 A 1099-01 2009.03.05

2 Dual Directional Couplor A & R DC-2600 20193 N/A 3 VOLTMETER BOONTON 9200C 361501AA 2008.11.08 4 Injection Clamp Liithi EM101 35260 N/A 5 ATTENUATOR BNOS AT50-6-250 521926 N/A 6 CDN (EUT) FCC FCC-801-M3-16A 3058 2008.05.18 7 CDN (AE) Knorr Bremse M3 12184 N/A

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

11.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-6: 2003 + A1: 2004

11.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

11.4 SEVERITY LEVELS Test specification Required Performance Criteria : A Level : 1kHz sine wave with 80% Amplitude Modulation: 3V Frequency range : 0.15-80MHz

Aux Equipment

EUT

CDN

Attenuator

Shield Room

Ground Reference Plane

Non-Conducted Table

AC Main

10cm

RF Signal Generator

Power Amplifier

10cm CDN AE

Dual Directional Couplor

VOLTMETER

Clamp

Page 35: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 33 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

11.5 OPERATING CONDITIONS OF THE EUT

1. Setup the EUT and Test Equipment as shown on 11.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test.

11.6 TEST PROCEDURE The EUT and load were placed on a table, which was 0.1 meters high from a Ground reference plane. Prior to the start of the test, a functional test was performed on the EUT to ensure proper operation. The EUT was also monitored during the test for any degradation of performance. Also, prior to the start of the test, clamp injection (RF current probe) calibration measurements were performed as described in IEC 61000-4-6: 2003 + A1: 2004.

For AC Power line test & For Signal Lines and Control Lines test:

The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp device couples to the signal and control lines of the EUT. After completion of the test, a functional test was performed on the EUT to ensure proper operation.

Page 36: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 34 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

11.7 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 60 % Test Power Supply AC 230V/50Hz

The measurement uncertainty is 2.03dB Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test. The

acceptance criteria were met, and the EUT passed the test.

Frequency Range (MHz)

Inject Line Field Strength

Inject Method

Required Criteria

Performance Criteria

Complied To Result

0.15~80 AC Line 3V CDN A A PASS

Page 37: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 35 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

12. MAGNETIC FIELD IMMUNITY MEASUREMENT 12.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date

1 ULTRA COMPACT GENERATOR EM TEST UCS 500-M 0500-15 2008.05.07

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

12.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-8: 1993 + A1: 2000

12.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same.

EUT

Test Generator

10 cm insulation

To AC Line

Shield Room

Non-Conducted Table

AL Plate

80cm

Induction Coil

AC LineInput

Ground Reference Plane (GRP)

Page 38: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 36 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

12.4 SEVERITY LEVELS

Test level for continuous field Test levels for short duration: 1to3s Level Magnetic Field Strength A/m Level Magnetic Field Strength A/m

1 1 1 n.a. 2 3 2 n.a. 3 10 3 n.a. 4 30 4 300 5 100 5 1000 X Special X Special

“X” is an open level. “X” is an open level. n.a.= not application

Test level (Magnetic Field Strength A/m)

Required Performance Criteria

Test Duration

1 A Continued Field 12.5 EUT OPERATION CONDITION

1. Setup the EUT and Test Equipment as shown on 12.3. 2. Power on. Active performance checking program to allow EUT execute its usual operation

mode during test. 12.6 TEST PROCEDURE

The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured at least 1m*1m min. The test magnetic Field shall be applied by the immersion method to the EUT, previously set-up as specified in 12.3. And 90 shall rotate the induction coil° in order to expose the EUT to the test field with different orientation.

12.7 TEST RESULT

Date of Test March 21, 2008 Temperature 25 ℃

Test Mode Mode 1 Humidity 60 %

Test Power Supply AC 230V/50Hz

Induction Coil Orientation

Testing Duration

Magnetic Field Strength A/m

Performance Criteria

Complied To Test Result

X 60 sec. 1 A PASS Y 60 sec. 1 A PASS Z 60 sec. 1 A PASS

The measurement uncertainty is 9.22% Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test.

The acceptance criteria were met, and the EUT passed the test.

Page 39: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 37 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

13. VOLTAGE DIPS AND SHORT INTERRUPTIONS TEST 13.1 TEST EQUIPMENT

Item Instrument Manufacturer Model Serial No. Next Cal. Date1 DIPS GENERATOR HAEFFELY PLING1610 083690-07 2008.08.13

Note: All equipment upon which need to calibrated are with calibration period of 1 year.

13.2 TEST METHOD

According to EN 55024:1998 + A1: 2001 + A2: 2003 IEC 61000-4-11: 2004

13.3 BLOCK DIAGRAM OF TEST SETUP

Note: This is a representative setup diagram for Table-top EUT. For Floor-standing EUT, the table will be removed with all others setup condition remain the same. 13.4 SEVERITY LEVELS

Voltage Dips and Interruption

Reduction(%) Test Duration

Required Performance Criteria

>95 10 ms B 30 500 ms C

>95 5s C 13.5 OPERATING CONDITIONS OF THE EUT

1. Setup the EUT and Test Equipment as shown on 13.3. 2. Power on the EUT. Acting performance checking program to allow EUT executing its usual

operation mode during test. 13.6 TEST PROCEDURE

The EUT and its load were placed on a table which was 0.8 meters height. For AC Power line test:

The EUT was connected to the power mains through a coupling device that directly couples to the Voltage Dips and Interruption Generator. Voltage dips of >95% for 10ms and 30% for 500ms were applied to the EUT three times with 10 sec intervals between dips. A power interruption of >95% for 5000ms (5 sec) was applied to the EUT three times with 60-second intervals between interruptions.

Voltage Dips/ Interruptions /Variations Simulator

EUT Load

To AC Line

Controller Computer Shield Room

Non-Conducted Table 80cm

AC Power Line to EUT

Page 40: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 38 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

13.7 TEST RESULT

Date of Test March 21, 2008 Temperature 22 ℃

Test Mode Mode 1 Humidity 60 % Test Power Supply AC 230V/50Hz

Item Phase Angle Reduction (%) Test Duration

(ms) Required Criteria

Complied to Criteria Result

0 C B PASS 45 C * * 90 C * * 135 C * * 180 C B PASS 225 C * * 270 C * *

Voltage Short

Interruptions

315

>95 5000

C * * 0 B A PASS 45 B * * 90 B * * 135 B * * 180 B A PASS 225 B * * 270 B * * 315

>95 10

B * * 0 C A PASS 45 C * * 90 C * * 135 C * * 180 C A PASS 225 C * * 270 C * *

Voltage Dips

315

30 500

C * * The measurement uncertainty is 6.8%

Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss of function, provided the function is self-recoverable, or can be restored

by the operation of the controls Additional Information

There was no observable degradation in performance. No false alarms or other malfunctions were observed during or after the test. The

acceptance criteria were met, and the EUT passed the test.

Page 41: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 39 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14. PHOTOGRAPHS FOR TEST 14.1 TEST PHOTOGRAPHS FOR CONDUCTION

Mode 1

Page 42: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 40 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.2 TEST PHOTOGRAPHS FOR RADIATED

Mode 1

Page 43: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 41 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.3 TEST PHOTOGRAPHS FOR HARMONIC/FLICKER

Mode 1

Page 44: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 42 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.4 TEST PHOTOGRAPHS FOR ESD

Mode 1

Page 45: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 43 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.5 TEST PHOTOGRAPHS FOR ESD TEST POINTS

8.4” Multimedia LCD Touch Monitor

Page 46: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 44 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

Adaptor

Page 47: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 45 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.6 TEST PHOTOGRAPHS FOR RS

Mode 1

Page 48: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 46 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.7 TEST PHOTOGRAPHS FOR EFT

Mode 1

Page 49: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 47 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.8 TEST PHOTOGRAPHS FOR SURGE

Mode 1

Page 50: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 48 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.9 TEST PHOTOGRAPHS FOR CS

Mode 1

Page 51: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 49 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.10 TEST PHOTOGRAPHS FOR MAGNETIC

Mode 1

Page 52: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 50 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

14.11 TEST PHOTOGRAPHS FOR DIPS

Mode 1

Page 53: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 51 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

15. PHOTOGRAPHS FOR PRODUCT

1. Front View Of 8.4” Multimedia LCD Touch Monitor (EUT) 2. Back View Of 8.4” Multimedia LCD Touch Monitor (EUT)

Page 54: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 52 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

3. IO Ports

Page 55: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 53 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

4. Front View Of Adapter 5. Back View Of Adapter

Page 56: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 54 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

6. AC Power Cable 7. VGA Cable

Page 57: Certificate of Test - Winmatedc.winmate.com.tw/_downloadcenter/2010/TestReport/0803CE0021_8.4... · Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GEST

GESTEK Lab Report No.:0803068E-01 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325

Accredited Lab. Of BSMI, NVLAP Page 55 of 55 Listed Lab. of Commerce, FCC, VCCI NVLAP Lab Code:200085-0

16. EMI/EMS REDUCTION METHOD DURING COMPLIANCE TESTING

No modification was made during testing.