Transcript
Page 1: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Technical leaflet

IC.PD.P21.B4.02

OEM Pressure transmitter for heavy duty applicationsType MBS 1250

Features• DesignedforuseinsevereindustrialOEM applications• Formediumandambienttemperaturesupto

125°C • Allstandardoutputsignals:4-20mA,0-5V, 1-5V,1-6V,0-10V,10-90%ratiometricvoltage

• Wettedpartsmadeofstainlesssteel• Awiderangeofpressureandelectrical

connections• EMCprotectionupto100V/m• Allversionswithintegratedpulse-snubber• UL508recognized• CEmarked• Dualoutputtransmitters,forfurther

information please contact Danfoss.

Description The compact heavy duty OEM pressure transmitterMBS1250isdesignedforuseinsevere hydraulic applications.Theintegratedpulse-snubberoffersahighdegreeofprotectionagainstcavitationsand

liquidhammer,andthewellthoughtoutdesignresultsinexcellentvibrationstabilityandanexceptionalrobustness.ThehighdegreeofEMIprotection equips the pressure transmitter to meetthemoststringentindustrialrequirements.

Technical data

Accuracy(incl.nonlinearity,hysteresisandrepeatability) ±0.5%FS

Thermalzeropointshift <±0.15%FS/10K

Thermal span shift <±0.15%FS/10K

Responsetimeliquids (10-90%) 1 ms

Overloadpressure(static) seetablebelow

Burst pressure Seetablebelow

Durability,P:10-90%FS >10 ×106 cycles

Performance (EN 60770)

Overload and burst pressure

Nominalpressure[bar] 6 10 16 25 40 60 100 160 250 400 600

Overload pressure 21 30 48 105 210 210 300 480 750 1200 1500

Burst pressure 280 400 640 700 1400 1400 2000 1600 2500 4000 >4000

Forhigherpressureranges,pleasecontactDanfossregardingMBS1200.

Page 2: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

2 IC.PD.P21.B4.02

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Environmental conditions

Mechanical conditions

Technical data (continued) Electrical specifications

Nom.outputsignal(Short-circuitprotected)

4to20mA(2wire)

0to5,1to51to6V

0to10V 10to90%ratiometric

Supplyvoltage[UB],polarityprotected 8to30V 8to30V 12to30V 5V±0.5V

Supply-currentconsumption − 4.5mA 4.5mA 4.5mA

Output impedance − ≤90Ω ≤90Ω ≤90Ω

Load[RL](connectedto0V) Seechartbelow RL≥10kΩ RL≥10kΩ RL≥5kΩ

Load[RL](connectedto+V) Seechartbelow Notpossible Notpossible RL≥5kΩ

Mediumtemperaturerange −40ºC →+125ºC

Ambienttemperaturerange seepage4

Compensatedtemperaturerange −40ºC →+125ºC

Transporttemperaturerange −40ºC →+125ºC

EMC-Emission EN 55022

EMC-ImmunityRFfield100V/m,26Mhz-1Ghz EN61000-6-2,EN61000-4-6,EN61000-4-3

DC isolation 250V

Vibrationstability 20g,10-2000Hz,sinus EN60068-2-6

Shockresistance 100g EN60068-2-27

Enclosure(dependingonelectricalconnection) Seepage5

Materials: Wettedparts Enclosure Pressure connection Electrical connection

17-4PHAISI304orplastic17-4PHSeepage4

Note: Loop current should not exceed 22 mA continu-ous or 25 mA tempo-rarily due to pressure peaks

4 to 20 mA output - min. / max. resistance vs. supply voltage

Page 3: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Ordering of standard code numbers

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

Ratiometric 10-90% of Vsup.

Deutsch DT 04

7/16-20UNF

0-10 063G4266 063G12660-40 063G4274 063G12740-160 063G4282 063G12820-250 063G4290 063G12900-400 063G4298 063G1298

G¼DIN3852-E

0-10 063G4265 063G12650-40 063G4273 063G12730-160 063G4281 063G12810-250 063G4289 063G12890-400 063G4297 063G12970-600 063G4305 063G1305

PackardMetriPack

0-10 063G4264 063G12640-40 063G4272 063G12720-160 063G4280 063G12800-250 063G4288 063G12880-400 063G4296 063G12960-600 063G4304 063G1304

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

1-5 V

Deutsch DT 04

G¼DIN3852-E

0-10 063G4263 063G12630-40 063G4271 063G12710-160 063G4279 063G12790-250 063G4287 063G12870-400 063G4295 063G12950-600 063G4303 063G1303

PackardMetriPack

0-10 063G4262 063G12620-40 063G4270 063G12700-160 063G4278 063G12780-250 063G4286 063G12860-400 063G4294 063G12940-600 063G4302 063G1302

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

4-20 mA

M12 x 1 7/16-20UNF

0-10 063G4267 063G12670-40 063G4275 063G12750-160 063G4283 063G12830-250 063G4291 063G12910-400 063G4299 063G1299

Deutsch DT 04

G¼DIN3852-E

0-10 063G4261 063G12610-40 063G4269 063G12690-160 063G4277 063G12770-250 063G4285 063G12850-400 063G4293 063G12930-600 063G4301 063G1301

PackardMetriPack

0-10 063G4260 063G12600-40 063G4268 063G12680-160 063G4276 063G12760-250 063G4284 063G12840-400 063G4292 063G12920-600 063G4300 063G1300

1)Gauge/relative2)Tobeorderedinthemultipleof50pcs.

From pressure connection To pressure connectionSingle pack

Code no.

G¼”DIN3852

7/16-20UNF-flare 063G03007/16-20UNF-2A 063G03019/16-18UNF-2A 063G0302

¼”NPT 063G0303R¼“ 063G0304

Ordering of adaptor code numbers

IC.PD.P21.B4.02 3

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Page 4: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Ordering of special versions 1 - -MBS 1250

Measuring Range (Gauge)0to6bar .............................. 180to10bar ........................... 2 00to16bar ........................... 2 20to25bar ............................ 2 40to40bar ........................... 260to60bar ........................... 280to100bar .......................... 3 00to160bar .......................... 3 20to250bar .......................... 3 40to400bar .......................... 360to600bar .......................... 38

Pressure referenceGauge(relative) .................................. 1

Output Signal4to20mA .......................................................... 10to5V ................................................................. 21to5V ................................................................. 31to6V ................................................................. 40to10V .............................................................. 5Ratiometric,10-90% ....................................... 6

Gasket

- Definedtypeofpressure

connection

Pressure connections (HEX 22 mm) GB04 ..............................G1/4ADIN3852-E1)

AC04 ..............................1/4-18NPT AC02 ..............................1/8-27NPT BD08 ..............................7/16-20UNF-2A1)

AF04 ..............................1/4-18NPTF AF02 ..............................1/8-27NPTF PT04 ..............................1/4-19PT

Electrical connections C 1 ....M12x1EN60947-5-2 C 2 ....RoundPackardMetri-Pack C 3 ....Deutschplug C 4 ....AMPsuperseal C 5 ....MiniDINplugEN175301-803CIndustrialstandard C6 .....DIN72585A1-4.1

1) Incl.Vitongasket. Min. medium temperature is −25ºC

Dimensions/ Combination

Type code C1 C2 C3 C4 C5 C6

M12x1EN60947-5-2 PackardMetri-Pack Deutsch DT04 AMPSuperseal MiniDINplugEN175301-803C

Industrial standard

Type code BD08 PT04 AC04/AF04 AC02/AF02 GB04

Recommended torque 18-20Nm 2-3turnsafterfingertightend

2-3turnsafterfingertightend

2-3turnsafterfingertightend

30-35Nm

7/16-20UNF-2A 1/4-19PT 1/4-18NPT/NPTF 1/8-27NPT/NPTF G1/4ADIN3852-E

Note: The diameter of all housings is 19 mm.

Note: HEX is 22 mm across flats.

DIN72585A1-4.1

4 IC.PD.P21.B4.02

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Page 5: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

IC.PD.P21.B4.02 5

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Typecodepage4

C1 C2 C3 C4 C5 C6

M12x1EN60947-5-2 PackardMetri-Pack Deutsch DT04 AMPSuperseal1.5 MiniDINplugEN175301-803

Industrial standard

DIN72585A1-4.1

Ambient temperature 4-20 mA-40to+100°C -40to+100°C -25to+100°C -40to+100°C -40to+100°C -40to+100°C

Ambient temperature, 0-5 V, 1-5 V, 1-6 V, 0-10 V, ratiometric 10-90%-40to+125°C -40to+125°C -40to+125°C -40to+125°C -40to+125°C -40to+125°C

EnclosureIP67 IP67 IP67 IP67 IP40 IP67

MaterialSS,PBT30%GFR

Gold(Au)plated

GlassfilledPBT30%GFR

Tin(Sn)plated

GlassfilledPBT30%GFRGold(Au)plated

GlassfilledPBT30%GFR

Tin(Sn)plated

304ss,PBT30%GFR

Tin(Sn)plated

GlassfilledPBT30%GFRGold(Au)plated

Electrical connections, 4-20 mA (2 wire)Pin1:+supply Pin2:Notused Pin3:÷supply Pin4:Notused

PinA:÷supply PinB:+supply PinC:Notused

Pin1:÷supply Pin2:+supply Pin3:Notused Pin4:Notused

Pin1:Notused Pin2:÷supply Pin3:+supply

Pin1:Notused Pin2:+supply Pin3:Notused Pin4:÷supply

Pin1:+supply Pin2:÷supply Pin3:Notused Pin4:Notused

Electrical connections, 0-5V, 1-5V, 1-6V, 0-10V, ratiometric 10-90%Pin1:+supply Pin2:Output Pin3:÷supply Pin4:Notused

PinA:÷supply PinB:+supply PinC:Output

Pin1:÷supply Pin2:+supply Pin3:Notused Pin4:Output

Pin1:Output Pin2:÷supply Pin3:+supply

Pin1:Output Pin2:+supply Pin3:Notused Pin4:÷supply

Pin1:+supply Pin2:÷supply Pin3:Output Pin4:Notused

Electrical connections

Page 6: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

©Dan

fossA/S,01-20

08DE-BD

Technical leaflet OEM pressure transmitter for heavy duty applications type MBS 1250

6 IC.PD.P21.B4.02


Top Related