oem pressure transmitter for heavy duty applications … · oem pressure transmitter for heavy duty...

6
Technical leaflet IC.PD.P21.B4.02 OEM Pressure transmitter for heavy duty applications Type MBS 1250 Features Designed for use in severe industrial OEM applications For medium and ambient temperatures up to 125°C All standard output signals: 4-20 mA, 0-5 V, 1-5 V, 1-6 V, 0-10 V, 10-90% ratiometric voltage Wetted parts made of stainless steel A wide range of pressure and electrical connections EMC protection up to 100 V/m All versions with integrated pulse-snubber UL 508 recognized CE marked Dual output transmitters, for further information please contact Danfoss. Description The compact heavy duty OEM pressure transmitter MBS 1250 is designed for use in severe hydraulic applications. The integrated pulse-snubber offers a high degree of protection against cavitations and liquid hammer, and the well thought out design results in excellent vibration stability and an exceptional robustness. The high degree of EMI protection equips the pressure transmitter to meet the most stringent industrial requirements. Technical data Accuracy (incl. nonlinearity, hysteresis and repeatability) ±0.5% FS Thermal zero point shift <± 0.15% FS/ 10K Thermal span shift <±0.15% FS/ 10K Response time liquids (10-90%) 1 ms Overload pressure (static) see table below Burst pressure See table below Durability, P: 10-90% FS >10 ×10 6 cycles Performance (EN 60770) Overload and burst pressure Nominal pressure [bar] 6 10 16 25 40 60 100 160 250 400 600 Overload pressure 21 30 48 105 210 210 300 480 750 1200 1500 Burst pressure 280 400 640 700 1400 1400 2000 1600 2500 4000 >4000 For higher pressure ranges, please contact Danfoss regarding MBS 1200.

Upload: phungquynh

Post on 15-Apr-2018

230 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Technical leaflet

IC.PD.P21.B4.02

OEM Pressure transmitter for heavy duty applicationsType MBS 1250

Features• DesignedforuseinsevereindustrialOEM applications• Formediumandambienttemperaturesupto

125°C • Allstandardoutputsignals:4-20mA,0-5V, 1-5V,1-6V,0-10V,10-90%ratiometricvoltage

• Wettedpartsmadeofstainlesssteel• Awiderangeofpressureandelectrical

connections• EMCprotectionupto100V/m• Allversionswithintegratedpulse-snubber• UL508recognized• CEmarked• Dualoutputtransmitters,forfurther

information please contact Danfoss.

Description The compact heavy duty OEM pressure transmitterMBS1250isdesignedforuseinsevere hydraulic applications.Theintegratedpulse-snubberoffersahighdegreeofprotectionagainstcavitationsand

liquidhammer,andthewellthoughtoutdesignresultsinexcellentvibrationstabilityandanexceptionalrobustness.ThehighdegreeofEMIprotection equips the pressure transmitter to meetthemoststringentindustrialrequirements.

Technical data

Accuracy(incl.nonlinearity,hysteresisandrepeatability) ±0.5%FS

Thermalzeropointshift <±0.15%FS/10K

Thermal span shift <±0.15%FS/10K

Responsetimeliquids (10-90%) 1 ms

Overloadpressure(static) seetablebelow

Burst pressure Seetablebelow

Durability,P:10-90%FS >10 ×106 cycles

Performance (EN 60770)

Overload and burst pressure

Nominalpressure[bar] 6 10 16 25 40 60 100 160 250 400 600

Overload pressure 21 30 48 105 210 210 300 480 750 1200 1500

Burst pressure 280 400 640 700 1400 1400 2000 1600 2500 4000 >4000

Forhigherpressureranges,pleasecontactDanfossregardingMBS1200.

Page 2: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

2 IC.PD.P21.B4.02

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Environmental conditions

Mechanical conditions

Technical data (continued) Electrical specifications

Nom.outputsignal(Short-circuitprotected)

4to20mA(2wire)

0to5,1to51to6V

0to10V 10to90%ratiometric

Supplyvoltage[UB],polarityprotected 8to30V 8to30V 12to30V 5V±0.5V

Supply-currentconsumption − 4.5mA 4.5mA 4.5mA

Output impedance − ≤90Ω ≤90Ω ≤90Ω

Load[RL](connectedto0V) Seechartbelow RL≥10kΩ RL≥10kΩ RL≥5kΩ

Load[RL](connectedto+V) Seechartbelow Notpossible Notpossible RL≥5kΩ

Mediumtemperaturerange −40ºC →+125ºC

Ambienttemperaturerange seepage4

Compensatedtemperaturerange −40ºC →+125ºC

Transporttemperaturerange −40ºC →+125ºC

EMC-Emission EN 55022

EMC-ImmunityRFfield100V/m,26Mhz-1Ghz EN61000-6-2,EN61000-4-6,EN61000-4-3

DC isolation 250V

Vibrationstability 20g,10-2000Hz,sinus EN60068-2-6

Shockresistance 100g EN60068-2-27

Enclosure(dependingonelectricalconnection) Seepage5

Materials: Wettedparts Enclosure Pressure connection Electrical connection

17-4PHAISI304orplastic17-4PHSeepage4

Note: Loop current should not exceed 22 mA continu-ous or 25 mA tempo-rarily due to pressure peaks

4 to 20 mA output - min. / max. resistance vs. supply voltage

Page 3: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Ordering of standard code numbers

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

Ratiometric 10-90% of Vsup.

Deutsch DT 04

7/16-20UNF

0-10 063G4266 063G12660-40 063G4274 063G12740-160 063G4282 063G12820-250 063G4290 063G12900-400 063G4298 063G1298

G¼DIN3852-E

0-10 063G4265 063G12650-40 063G4273 063G12730-160 063G4281 063G12810-250 063G4289 063G12890-400 063G4297 063G12970-600 063G4305 063G1305

PackardMetriPack

0-10 063G4264 063G12640-40 063G4272 063G12720-160 063G4280 063G12800-250 063G4288 063G12880-400 063G4296 063G12960-600 063G4304 063G1304

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

1-5 V

Deutsch DT 04

G¼DIN3852-E

0-10 063G4263 063G12630-40 063G4271 063G12710-160 063G4279 063G12790-250 063G4287 063G12870-400 063G4295 063G12950-600 063G4303 063G1303

PackardMetriPack

0-10 063G4262 063G12620-40 063G4270 063G12700-160 063G4278 063G12780-250 063G4286 063G12860-400 063G4294 063G12940-600 063G4302 063G1302

Output signal Electrical connection Pressure connectionMeasuring range

Pe 1) [bar]Industrial pack 2)

Code no. Single pack

Code no.

4-20 mA

M12 x 1 7/16-20UNF

0-10 063G4267 063G12670-40 063G4275 063G12750-160 063G4283 063G12830-250 063G4291 063G12910-400 063G4299 063G1299

Deutsch DT 04

G¼DIN3852-E

0-10 063G4261 063G12610-40 063G4269 063G12690-160 063G4277 063G12770-250 063G4285 063G12850-400 063G4293 063G12930-600 063G4301 063G1301

PackardMetriPack

0-10 063G4260 063G12600-40 063G4268 063G12680-160 063G4276 063G12760-250 063G4284 063G12840-400 063G4292 063G12920-600 063G4300 063G1300

1)Gauge/relative2)Tobeorderedinthemultipleof50pcs.

From pressure connection To pressure connectionSingle pack

Code no.

G¼”DIN3852

7/16-20UNF-flare 063G03007/16-20UNF-2A 063G03019/16-18UNF-2A 063G0302

¼”NPT 063G0303R¼“ 063G0304

Ordering of adaptor code numbers

IC.PD.P21.B4.02 3

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Page 4: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

Ordering of special versions 1 - -MBS 1250

Measuring Range (Gauge)0to6bar .............................. 180to10bar ........................... 2 00to16bar ........................... 2 20to25bar ............................ 2 40to40bar ........................... 260to60bar ........................... 280to100bar .......................... 3 00to160bar .......................... 3 20to250bar .......................... 3 40to400bar .......................... 360to600bar .......................... 38

Pressure referenceGauge(relative) .................................. 1

Output Signal4to20mA .......................................................... 10to5V ................................................................. 21to5V ................................................................. 31to6V ................................................................. 40to10V .............................................................. 5Ratiometric,10-90% ....................................... 6

Gasket

- Definedtypeofpressure

connection

Pressure connections (HEX 22 mm) GB04 ..............................G1/4ADIN3852-E1)

AC04 ..............................1/4-18NPT AC02 ..............................1/8-27NPT BD08 ..............................7/16-20UNF-2A1)

AF04 ..............................1/4-18NPTF AF02 ..............................1/8-27NPTF PT04 ..............................1/4-19PT

Electrical connections C 1 ....M12x1EN60947-5-2 C 2 ....RoundPackardMetri-Pack C 3 ....Deutschplug C 4 ....AMPsuperseal C 5 ....MiniDINplugEN175301-803CIndustrialstandard C6 .....DIN72585A1-4.1

1) Incl.Vitongasket. Min. medium temperature is −25ºC

Dimensions/ Combination

Type code C1 C2 C3 C4 C5 C6

M12x1EN60947-5-2 PackardMetri-Pack Deutsch DT04 AMPSuperseal MiniDINplugEN175301-803C

Industrial standard

Type code BD08 PT04 AC04/AF04 AC02/AF02 GB04

Recommended torque 18-20Nm 2-3turnsafterfingertightend

2-3turnsafterfingertightend

2-3turnsafterfingertightend

30-35Nm

7/16-20UNF-2A 1/4-19PT 1/4-18NPT/NPTF 1/8-27NPT/NPTF G1/4ADIN3852-E

Note: The diameter of all housings is 19 mm.

Note: HEX is 22 mm across flats.

DIN72585A1-4.1

4 IC.PD.P21.B4.02

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Page 5: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

IC.PD.P21.B4.02 5

Technical leaflet OEM pressure transmitters for heavy duty applications, type MBS 1250

Typecodepage4

C1 C2 C3 C4 C5 C6

M12x1EN60947-5-2 PackardMetri-Pack Deutsch DT04 AMPSuperseal1.5 MiniDINplugEN175301-803

Industrial standard

DIN72585A1-4.1

Ambient temperature 4-20 mA-40to+100°C -40to+100°C -25to+100°C -40to+100°C -40to+100°C -40to+100°C

Ambient temperature, 0-5 V, 1-5 V, 1-6 V, 0-10 V, ratiometric 10-90%-40to+125°C -40to+125°C -40to+125°C -40to+125°C -40to+125°C -40to+125°C

EnclosureIP67 IP67 IP67 IP67 IP40 IP67

MaterialSS,PBT30%GFR

Gold(Au)plated

GlassfilledPBT30%GFR

Tin(Sn)plated

GlassfilledPBT30%GFRGold(Au)plated

GlassfilledPBT30%GFR

Tin(Sn)plated

304ss,PBT30%GFR

Tin(Sn)plated

GlassfilledPBT30%GFRGold(Au)plated

Electrical connections, 4-20 mA (2 wire)Pin1:+supply Pin2:Notused Pin3:÷supply Pin4:Notused

PinA:÷supply PinB:+supply PinC:Notused

Pin1:÷supply Pin2:+supply Pin3:Notused Pin4:Notused

Pin1:Notused Pin2:÷supply Pin3:+supply

Pin1:Notused Pin2:+supply Pin3:Notused Pin4:÷supply

Pin1:+supply Pin2:÷supply Pin3:Notused Pin4:Notused

Electrical connections, 0-5V, 1-5V, 1-6V, 0-10V, ratiometric 10-90%Pin1:+supply Pin2:Output Pin3:÷supply Pin4:Notused

PinA:÷supply PinB:+supply PinC:Output

Pin1:÷supply Pin2:+supply Pin3:Notused Pin4:Output

Pin1:Output Pin2:÷supply Pin3:+supply

Pin1:Output Pin2:+supply Pin3:Notused Pin4:÷supply

Pin1:+supply Pin2:÷supply Pin3:Output Pin4:Notused

Electrical connections

Page 6: OEM Pressure transmitter for heavy duty applications … · OEM Pressure transmitter for heavy duty ... , please contact Danfoss regarding ... Technical leaflet OEM pressure transmitter

©Dan

fossA/S,01-20

08DE-BD

Technical leaflet OEM pressure transmitter for heavy duty applications type MBS 1250

6 IC.PD.P21.B4.02