Fire/Alarm/Security/CommunicationsProduct Catalog
FPO
Surge Protection For Business-Critical ContinuityTM
Protection Against Damage, Disruption, and Costly Downtime of your …
Mission-Critical Equipment … Today’s advanced commercial/residential fire, alarm, security and telecommunication systems are more sophisticated than ever before. In a nanosecond, transients can disrupt, disable and ruin your mission-critical equipment. It’s why companies turn to Emerson Network Power Surge Protection for their line of surge suppression and filtering products to protect sensitive equipment from excessive maintenance costs, damage and costly downtime.
Emerson Network Power’s comprehensive portfolio includes products for Data/Signal Line Protection, AC Power Surge Protection, and Filtering/Line Conditioning. Plus, all of our engineered power-quality solutions are backed by a dedicated team of power-quality specialists who are available to share their applications and integration knowledge with you. We’re here to help!
Why take chances by putting the security of your mission-critical equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind.
To learn more about the world’s most trusted lineup of multi stage, hybrid, solid state, power quality products, call us toll-free at 800-288-6169, or visit our Web site at www.emersonnetworkpower.com/surge.
Table of ContentsApplication Product Page #
CCTV SySTemS Application Drawing 2Zone/Loop/Data Edco™ PC642 Series 3120 VAC Heavy Duty 120 Volt AC Edco™ HSP Series 4Plug-in Surge Protection/Active Tracking™ Filter Islatrol™ SP-6TVN 5CCTV & Data Applications/Coax Edco™ CX Series 6Closed Circuit TV Protection Edco™ CCTV-1 7One- and Two-Pair Signal Line Protection Edco™ FAS-1 and FAS-2 Series 7Two-Pair Signaling Circuit Protector (Modular) Edco™ PHC Series 8 CAT6/CAT5 Power Over Ethernet Edco™ CAT6-5POE Series 9Channel Rackmount Edco™ RM-CX06-16R 9
Fire AlArm Application Drawing 10Zone/Loop/Data Edco™ PC642 Series 11Two-Pair SLC Loop Protector (Modular) Edco™ SLCP Series 12Two-Line Telephone Protection (Modular) Edco™ PC2-TEL 12Two-Pair Signaling Circuit Protector (Modular) Edco™ PHC Series 13120 VAC Heavy Duty 120 Volt AC Edco™ HSP Series 14120/240 VAC Heavy Duty (Parallel) PowerSure™ EMC-240B 15One- and Two-Pair Signal Line Protection Edco™ FAS-1 and FAS-2 Series 16Medium Duty 120 VAC — Single Phase PowerSure™ FAS-120AC 17
BurglAr 12VDC Application Drawings 18One- and Two-Pair Signal Line Protection Edco™ FAS-1 and FAS-2 Series 19Plug-in Surge Protection (Active Tracking™ Filter) Islatrol™ SP-6TVN 20RJ11/RJ31X Telephone Protection Edco™ FAS-TEL and FAS-31XT 21Single-Pair Medium Duty Low Voltage Zone/Horn/Strobe/Data Edco™ TER Series 22Two-Line Telephone Protection (Modular) Edco™ PC2-TEL 22
ACCeSS CONTrOlApplication Drawing 23Electric Door Suppressor Edco™ EL-EDS 24Two-Pair Data/Signal Line Power Edco™ 5W8-30 25RJ11/RJ31X Telephone Protection Edco™ FAS-TEL and FAS-31XT 26120 VAC Heavy Duty 120 Volt AC Edco™ HSP Series 27Zone/Loop/Data Edco™ PC642 Series 28Data Circuit Protection Edco™ LCDP 29
COmmuNiCATiONSOne- and Two-Pair Signal Line Protection Edco™ FAS-1 and FAS-2 Series 30DIN Rail Protection Edco™ DRS (DC) Series 31High Frequency Coax Protector — N-Type Edco™ CX-HFN 32High Frequency Coax Protector — F-Type Edco™ CATV-DF 32Intercom/Speaker Punch Block Protection (Parallel) Edco™ OPX Series 33Intercom/Speaker Punch Block Protection (Series) Edco™ PB Series 34Telecom/Punch Block Protection Edco™ H Series 35Data/Signal Line/Punch Block Protection Edco™ COHP Series 36Fits Standard 66MI-50 Punch Down Blocks Edco™ MGB Ground Rail 36RJ11/RJ31X Telephone Protection Edco™ FAS-TEL and FAS-31XT 37Multi-Channel Rackmount Edco™ RM-CAT6-POE Series 38Data Circuit Protection Edco™ LCDP 38 RJ-45 Telephone/Data Edco™ RJA-RJD Series 39Terminating Assembly Edco™ TBLK Assembly 40CAT6/CAT5 Power Over Ethernet Edco™ CAT6-5POE Series 40Key Systems Edco™ MOD-12 41
VideoHead-End
EquipmentRack
Multiplexer
SP 1or
SP 2AC Power
Video
Power
Video
Power
RS-485, RS-422 (PTZ)
Power Over Ethernet (POE)
SP 3
SP 5
SP 3
SP 5
SP 6
SP 7 SP 7
SP 6
SP 5
SP 4
SP 5
SP 4
Legend
SP 1 ... HSP121BT-1RUSP 2 ... SP-6TVNSP 3 ... CX06-Mor ...... RM-CX06-16R (16 ch.)SP 4 ... CX06-MI
SP 5 ... FAS-1-043HC (2.5A)or ...... PHC-043* (5A)SP 6 ... PC642C-008LC*SP 7 ... CAT6-5 POE-FF or -MF *Needs PCB1B Base
Exterior FixedCamera
Exterior Camerawith PTZ
Exterior POECamera
For POE with PTZcontact Edco
2
Protecting CCTV Systems Application Drawing
CCTV Systems
3
CCTV Systems
edco™ PC642 Series Zone/Loop/DataThe Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance by several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
performance and survivability.
The Edco PC642 Series card edge module is gold plated, double sided, and is
designed to mate with the Edco PCB1B gold-plated female terminal connector.
When snapped together, the data circuits “pass thru” the protector in a serial
fashion from the four “Field Side” terminals to the four “Electronics Side”
terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building-
Approved Ground per Edco Technical Bulletin # 2015.
Features ■ Three-stage hybrid protection
■ Sneak/fault current protection
■ Resettable fusing — PTCs
■ Low capacitance option
■ Plug-in module
■ Fast response time
■ Requires Edco PCB1B base
■ Order PC642PTU — an invaluable troubleshooting tool
■ 5 year warranty
eDCO PCB1B BASe SOlD SePArATely
OPTiON:DiN rAil KiT AVAilABleOrDer PArT # 11604KiT-PC
general Technical SpecificationsMaximum Operating Voltage 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC
Clamping Voltage 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC
Operating Current 0.15A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology GDT, SAD, w/Series PTC
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base)
Weight 1 oz
Certification UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 150 milliamperes.
Terminal Assignments
PCB1B:
Unprotected Pair 2
Unprotected Pair 1
Protected Pair 2
Protected Pair 1
Keying Pin
Even TerminalsOdd Terminals
Field SideElectronics Side
9
7
5
3
1
10
8
6
4
2
1.0
{ }
}{ 2.125" 2.4"
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Ordering information
PC642
PCB1B
APPliCATiON:
RS485, RS422: PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
RS232: PC642C-020 & PCB1B
E-Net, 10 Base T: PC642C-030LC & PCB1B
4–20 ma: PC642C-036 & PCB1B
How To Specify The Appropriate model
-
Voltage Clamp
60 Volts50 Volts43 Volts36 Volts30 Volts
15 Volts8 Volts
2 0 0
PC642C
20 Volts
**200 Volts0 6 0 0 5 0 0 4 3
0 3 0 0 2 0
0 3 6
0 1 5 0 0 8
no suffixstage 2 clampeach line-to-groundstage 2 clampline-to-line only
stage 2 clamp line-to-lineand each line to ground
D
Xlow capacitance option stage2 clamp line-to-line and eachline to ground
**Not UL Listed
LC
4
CCTV Systems
edco™ HSP Series120 VAC Heavy Duty 120 Volt ACThe Edco HSP Series is an advanced three-stage hybrid, solid state power-
line protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Maximum Operating Voltage 120 VAC
Clamping Voltage 325 VAC
Operating Current 15A
I-Nominal (In) 3 kA
Total Peak Surge Current 39 kA (8 x 20 µs)
Operating Frequency 47–63 Hz
EMI Attenuation (100 kHz to 100 MHz) > 40 dB
SPD Technology Metal Oxide Varistors (MOVs) w/ L-C Filter
Modes Of Protection Line-to-Neutral, Line-to-Ground, Neutral-to-Ground
Status Indication Power On & MOVs functional
Connection Type 3 Position, 20A Terminal Block w/Compression Screws Terminals Accept Up To 14 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L
Weight 10 oz
Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2
general Technical Specifications Dimensions
Features ■ Fast response time
■ Failure indicator
■ Power line tracking
■ Filtering
■ Polycarbonite NEMA 4X enclosure (HSP121A)
■ Three-stage hybrid design
■ Replaceable fuse
■ 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A)
■ 5 year warranty
GND
N
AC
GND
N
AC
3/4" Conduit Fitting 3/4" Conduit Fitting
1/2" Conduit Fitting 1/2" Conduit Fitting
Mounting – HSP121AHoles 3/16" Dia.
Mounting – HSP121BT-1RUHoles 3/16" Dia.
Light On – NormalLight Off – Requires Service
eDCO HSP121BT-1ru
eDCO HSP121A
5
CCTV Systems
islatrol™ SP-6TVNPlug-in Surge Protection/Active Tracking™ FilterThe Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device
that plugs into a standard duplex receptacle. It features uniquely designed
repositionable outlets and protects against damaging power disturbances
traveling through your wiring into your electrical outlets.
Features ■ Plugs into standard 120V, 15A
electrical outlet
■ Total peak surge current capacity of 39 kA
■ Cables for telephone, video, and data connectors included
■ Repositionable outlets rotate to accommodate available space
■ Perfect for tight spaces, behind furniture
and appliances
■ Intelligent monitoring against improper wiring/grounding
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ 5 year warranty
general Technical Specifications
AC Power Protection
Nominal Operating Voltage 120 VAC, Single Phase
Operating Voltage Range 120 VAC +/- 10%
Operating Frequency Range 47–63 Hz
Rated Output 15A
ANSI/IEEE C62.41 Category Category A & B
Connection Type (6) 5-15R Receptacles and 5-15P Plug
Phase Configuration 2 Wire + Gnd
Size 7.5 x 4.75 x 1.75 (Inches)
Enclosure High Impact Plastic
Weight 2.0 lbs (0.9 kgs)
Modes Of Protection L – N, L – G, N – G
Indication of Suppression Status Status Indicator
Response Time < .5 ns Normal Mode
Certification ANSI/UL 1449 Third Edition Type 3
Warranty 5 Year
maximum Continuous Operating Voltage (mCOV)
Line To Neutral 130 VAC
Peak Surge Current (8 x 20 ms)
Line To Neutral 13 kA
Line To Ground 13 kA
Neutral To Ground 13 kA
Total 39 kA
ANSi/ieee C62.41 Cat A ringwave (6 kV, 200A, 100 kHz)
Normal Mode 265V
Common Mode 290V
ANSi/ieee C62.41 Cat B ringwave (6 kV, 500A, 100 kHz)
Normal Mode 275V
Common Mode 290V
Frequency response
Normal Mode 60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz
Common Mode 40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz
low Voltage Protection Video 1 & 2 Phone Network
Connection Type Type “F” Type RJ-11 Type RJ-45
Cables Provided 6 (2x) Type “F” RJ-11 Male RJ-45 Male 6' Ends 6' Ends Ends
Peak Surge Current 5 kA 2 kA 3 kA (8 x 20 µs) (10 x 1000 µs) (8 x 20 µs)
Capacitance <12 pf <50 pf <70 pf
Protection Level L-G T-R, T-G, R-G L-G (8 Lines)
Clamping Voltage (DC) 145 V 270-350 V 30 V
Attenuation 1 dB @ 2 Ghz N/A N/A
rePOSiTiONABle OuTleTS
6
edco™ CX SeriesCCTV & Data Applications/CoaxThe Edco CX Series Surge Protective Devices (SPDs) implement three-stage
hybrid technology. The SPDs address over-voltage transients with a primary
Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD)
components. Over-current protection, e.g. sneak and fault currents, are
mitigated with solid-state resettable fuses —PTCs. The Edco CX Series SPDs
are designed in accordance with NFPA 780 (2004 edition) requirements,
with up to 20 kA of surge current capability. The Edco CX06-MI model has an
isolated ground and is recommended for use at the camera end.
Features ■ Sneak/fault current protection
■ Low insertion loss
■ Shielded case
■ CX06-MI has an isolated ground
■ 5 year warranty
general Technical SpecificationsMaximum Operating Voltage 5 VDC
Clamping Voltage 6 VDC
Operating Current 0.17A
Peak Surge Current 20 kA (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 1 dB at 20 MHz
SPD Technology GDT, SAD, w/Series PTC
Connection Type BNC, 50/75 Ohms
Operating Temperature -40°C to +85°C
Dimensions (Inches) M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L SBL = 1.7H x 1.4W x 2.8L
Weight M = 2.3 oz MI = 3 oz
Certification UL 497B
Head End CX06-M
Camera End CX06-MI CX06-MI-SBL
• Other configurations available — please consult factory
Ordering information
CCTV Systems
OPTiON:DiN rAil KiT AVAilABleOrDer PArT # 11604KiT-CX
CX06-mi-SBl installation
edco™ FAS-1 and FAS-2 SeriesOne- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi-stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features ■ Lightning protection for low voltage
■ Data/signal lines
■ Multi stage protection
■ Common mode and differential protection mode
■ Automatic recovery
■ 5 year warranty
Maximum Operating Voltage 15, 24, 36, 52 VDC
Clamping Voltage 18, 33, 43, 60 VDC
Operating Current 2.5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology GDT, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L
Weight FAS-1 = 3.5 oz FAS-2 = 7 oz
Certification UL 497B
FAS-1-018 HC (One-pair) 12 VDC Use FAS-2-018 HC (Two-pair)
FAS-1-033 HC (One-pair) 24 VDC Use FAS-2-033 HC (Two-pair)
FAS-1-043 HC (One-pair) 24 VAC Use FAS-2-043 HC (Two-pair)
FAS-1-060 HC (One-pair)* 48V Systems Use FAS-2-060 HC (Two-pair)*
*Not UL listed
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes.
general Technical Specifications Ordering informationinstallationUnprotected Or Field Side
Protected Equipment
Ground Lug
Equi
p. Line
10–14 AWG
Features ■ Automatic recovery
■ Low insertion loss
■ Easily installed
■ Shielded case
■ Miniature size
■ 5 year warranty
Maximum Operating Voltage 5 VDC
Clamping Voltage 90 VDC (Spark Over Voltage)
Operating Current 1A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 1 GHz
Insertion Loss < 0.5 dB at 500 MHz <1.0 dB at 900 MHz
SPD Technology Gas Discharge Tube (GDT)
Connection Type BNC, 75 Ohm
Operating Temperature -40°C to +85°C
Dimensions (Inches) 0.6H x 0.6W x 2.0L
Weight 1 oz
general Technical Specifications
7
edco™ CCTV-1 Closed Circuit TV ProtectionThe Edco CCTV-1 application is specifically designed for lightning protection on
closed circuit TV systems. The protector is easily installed with standard type BNC
coax connectors. The Edco CCTV-1 offers low loss, even at frequencies approaching
500 Mhz. This is important for error-free data communication applications.
CCTV Systems
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
8
CCTV Systems
edco™ PHC SeriesTwo-Pair Signaling Circuit Protector (modular)The Edco PHC Series is designed to protect two pairs of wires specifically
for alarm and security systems where operating currents can be as high
as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid
implementing a staged complement of MOVs, copper wound inductors and
Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms
per pair. These products are intended to mate with an Edco PCB1B
gold-plated female terminal connector.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close
as practical to the protected equipment. Terminal 1 and/or terminal 10
should be connected to Building-Approved Ground with 12- or 10-gauge
solid wire.
general Technical Specifications Ordering information How To Specify The Appropriate model
Features ■ Three-stage protection
■ Differential protection
■ Common mode protection
■ Plug-in module
■ Automatic recovery
■ Fast response time
■ Continuous current up to 5 Amps
■ UL 497B listed
■ Requires Edco PCB1B base
■ Order PC642PTU — an invaluable troubleshooting tool
■ 5 year warranty
Maximum Operating Voltage 12, 18, 24, 36, 52, 70, 120 VDC
Clamping Voltage 15, 20, 30, 43, 60, 100, 150 VDC
Operating Current 5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology MOV, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 3.7H x 1.75W x 2.375L (PHC + PCB1B Base)
Weight 8 oz
Certification UL 497B
24V Horn, Strobe, Bell PHC-043 & PCB1B
70V Speaker Lines PHC-SP70 & PCB1B
eDCO PCB1B BASe SOlD SePArATely
PCB1B:
Unprotected Pair 2
Unprotected Pair 1
Protected Pair 2
Protected Pair 1
Keying Pin
Even TerminalsOdd Terminals
Field SideElectronics Side
9
7
5
3
1
10
8
6
4
2
1.0
{ }
}{ 2.125" 2.4"
Ground Terminal 1 Or 10 To Building-Approved Ground
Terminal Assignments
Voltage Clamp
* Not UL listed
Applications Part Number
Dimensions
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
eDCO PCB1B BASe SOlD SePArATely
Maximum Operating Voltage 5 VDC
Clamping Voltage 6 VDC
Operating Current 0.15A
Peak Surge Current 20 kA (8 x 20 µs)
Frequency Range 0 to 100 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology GDT, SAD, w/Series PTC
Connection Type BNC, 50/75 Ohm
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.75H x 19W x 2.0D (1U)
Weight 3.2 lbs
Certification UL 497B
edco™ rm-CX06-16r Channel RackmountThe Edco RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax SPD
implementing three-stage hybrid technology. The SPD addresses over-voltage
transients with a primary Gas Discharge Tube (GDT), and secondary Silicon
Avalanche Diode (SAD) components. Over-current protection, e.g., sneak and
fault currents, are mitigated with new solid-state resettable fuses — PTCs. The
Edco RM-CX06-16R SPD is designed in accordance with NFPA 780 (2004 edition)
requirements, with up to 20 kA of surge current capability.
general Technical Specifications
Features ■ Sneak/fault current protection
■ Low insertion loss
■ Shielded case
■ 16 channel
■ 1 year warranty
9
edco™ CAT6-5POe Series CAT6/CAT5 Power Over EthernetThe Edco CAT6-5POE Series is designed to work on Category 5 Power-Over-
Ethernet transmission lines as well as Category 6 applications. Ideal to protect
expensive equipment against surges and transients entering a building on
exposed transmission lines. Available in both female to female and male to
female RJ-45 connectors.
Features ■ Exceeds CAT5 & 6 transmission values
■ CAT5 POE compatible
■ CAT6 compatible
■ Applications up to 60 VDC @ 300 mA
■ 1 year warranty
Maximum Operating Voltage 60 VDC
Clamping Voltage 65 VDC
Operating Current 300 mA
Peak Surge Current 60A (10 x 1000 µs)
Frequency Range 0 to 250 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type RJ-45 Jacks
Operating Temperature -40°C to +85°C
Dimensions (Inches) 0.8H x 1.0W x 2.3L (FF) 0.8H x 1.0W x 3.0L (MF)
Weight 1 oz
RJ-45 (Female-Female) CAT6-5POE-FF
RJ-45 (Male-Female) CAT6-5POE-MF
general Technical Specifications
CCTV Systems
Fire AlarmPanel
(24 VDC Typical)
AC Power
SLC Loop — Penetrating Exterior
RS-485 Network — Exterior
Post Indicator Valve Circuit — Exterior
Notification Appliance Circuit — Exterior
Printer Circuit To Guard House
LegendSP 1 .... FAS-120ACSP 2 .... HSP-121BT1RUSP 3 .... PC2-TEL*SP 4 .... SLCP-43*SP 5 .... PC642C-008LC*
SP 6 .... FAS-1-033HCSP 7 .... PHC-043*SP 8 .... PC642C-020*SP 9 .... EMC-240BSP 3
(Over 1000 feet need protection at wall penetration point)
SP 4
SP 5
SP 6
SP 7
SP 8(RS-232 Typical)
SP 8
SP 7
SP 5
SP 4
*Needs PCB1B Base
TelephoneLine
SP 6
SP 1or
SP 2or
SP 9
10
Fire Alarm
Protecting Fire Alarm Systems Application Drawing
11
edco™ PC642 Series Zone/Loop/DataThe Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses
(PTCs). The PTCs increase resistance by several orders of magnitude when
over-currents exceed safe levels. A normal state resumes when over-currents
are removed. The ability to self-restore in this manner significantly increases
suppressor performance and survivability.
The Edco PC642 card edge module is gold plated, double sided, and
is designed to mate with the Edco PCB1B gold-plated female terminal
connector. When snapped together, the data circuits “pass thru” the protector
in a serial fashion from the four “Field Side” terminals to the four “Electronics
Side” terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to
Building-Approved Ground per Edco Technical Bulletin # 2015.
Features ■ Three-stage hybrid protection
■ Sneak/fault current protection
■ Resettable fusing — PTCs
■ Low capacitance option
■ Plug-in module
■ Fast response time
■ Requires Edco PCB1B base
■ Order PC642PTU — an invaluable troubleshooting tool
■ 5 year warranty
eDCO PCB1B BASe SOlD SePArATely
general Technical SpecificationsMaximum Operating Voltage 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC
Clamping Voltage 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC
Operating Current 0.15A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology GDT, SAD, w/Series PTC
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base)
Weight 1 oz
Certification UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 150 milliamperes.
Terminal Assignments
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Ordering information
APPliCATiON:
RS485, RS422: PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
RS232: PC642C-020 & PCB1B
E-Net, 10 Base T: PC642C-030LC & PCB1B
4–20 ma: PC642C-036 & PCB1B
How To Specify The Appropriate model
**200 Volts**Not UL Listed
Voltage Clamp
Fire Alarm
OPTiONDiN rAil KiT AVAilABleOrDer PArT # 11604KiT-PC
Features ■ Compatible with SLC circuits
■ Line-to-ground protection
■ State-of-the-art silicon technology
■ Over-current protection
■ 497B UL listed
■ Requires Edco PCB1B base
■ PC642PTU (Pass Thru Unit) available for troubleshooting
■ 5 year warranty
edco™ SlCP Series Two-Pair SLC Loop Protector (Modular)The Edco SLCP Series are four-wire modules designed to protect signaling
line circuits (SLC). The device has 0 ohms of resistance and offers line-to-
ground protection.
eDCO PCB1B BASe SOlD SePArATely
Maximum Operating Voltage 5, 12, 18, 24, 32, 36, 48, & 52 VDC
Clamping Voltage 8, 15, 20, 30, 36, 43, 50, & 60 VDC
Operating Current 1A
Peak Surge Current 250A (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (SLCP + PCB1B Base)
Weight 1 oz
Certification UL 497B
general Technical Specifications Ordering information
edco™ PC2-Tel Two-Line Telephone Protection (Modular)The Edco PC2-TEL is a solid state, two-line telephone interface protector
module. This unit is specifically designed to protect both phone lines
required by commercial fire panels.
Features ■ Tip-to-ring protection
■ Tip- and ring-to-ground protection
■ Over-current protection
■ Resettable solid state fuses — PTC
■ UL listed 497A
■ Requires PCB1B base
■ PC642PTU (Pass Thru Unit) available for trouble shooting
■ 5 year warranty
Maximum Operating Voltage 250 VDC
Clamping Voltage 270 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 T & R To Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Series PTC and Silicon Avalanche Diode (SAD)
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (PC2TEL + PCB1B Base)
Weight 1 oz
Certifications UL 497A, CUL
eDCO PCB1B BASe SOlD SePArATely
general Technical Specifications
12
Fire Alarm
0 0 8
0 1 5
0 2 0
0 3 0
0 3 6
0 4 3
0 5 0
0 6 0
8 Volts
15 Volts
20 Volts
30 Volts
36 Volts
43 Volts
50 Volts
60 Volts
S L C P
ClampingVoltage
edco™ PHC Series Two-Pair Signaling Circuit Protector (Modular)The Edco PHC Series is designed to protect two pairs of wires specifically
for alarm and security systems where operating currents can be as high
as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid
implementing a staged complement of MOVs, copper wound inductors and
Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms
per pair. These products are intended to mate with an Edco PCB1B
gold-plated female terminal connector.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close
as practical to the protected equipment. Terminal 1 and/or terminal 10
should be connected to Building-Approved Ground with 12- or 10-gauge
solid wire.
general Technical Specifications Ordering information
Features ■ Three-stage protection
■ Differential protection
■ Common mode protection
■ Plug-in module
■ Automatic recovery
■ Fast response time
■ Continuous current up to 5 Amps
■ UL 497B listed
■ Requires Edco PCB1B base
■ Order PC642PTU — an invaluable troubleshooting tool
■ 5 year warranty
Maximum Operating Voltage 12, 18, 24, 36, 52, 70, 120 VDC
Clamping Voltage 15, 20, 30, 43, 60, 100, 150 VDC
Operating Current 5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology MOV, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 3.7H x 1.75W x 2.375L (PHC + PCB1B Base)
Weight 8 oz
Certification UL 497B
24V Horn, Strobe, Bell PHC-043 & PCB1B
70V Speaker Lines PHC-SP70 & PCB1B
eDCO PCB1B BASe SOlD SePArATely
PCB1B:
Unprotected Pair 2
Unprotected Pair 1
Protected Pair 2
Protected Pair 1
Keying Pin
Even TerminalsOdd Terminals
Field SideElectronics Side
9
7
5
3
1
10
8
6
4
2
1.0
{ }
}{ 2.125" 2.4"
Ground Terminal 1 Or 10 To Building-Approved Ground
Terminal Assignments
0 1 5
0 2 0
0 3 0
0 4 3
0 6 0
S P 7 0
1 3 0 R M S
15 Volts
20 Volts
30 Volts
43 Volts
60 Volts
*100 Volts
*150 Volts
*Not UL Listed
(For Horn, Bell, Strobes)
(For 120V Signal Lines)
Voltage ClampP H C
Applications Part Number
Dimensions
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
How To Specify The Appropriate model
13
Fire Alarm
Maximum Operating Voltage 120 VAC
Clamping Voltage 325 VAC
Operating Current 15A
I-Nominal (In) 3 kA
Total Peak Surge Current 39 kA (8 x 20 µs)
Operating Frequency 47–63 Hz
EMI Attenuation (100 kHz to 100 MHz) > 40 dB
SPD Technology Metal Oxide Varistors (MOVs) w/ L-C Filter
Modes Of Protection Line-to-Neutral, Line-to-Ground, Neutral-to-Ground
Status Indication Power On & MOVs functional
Connection Type 3 Position, 20A Terminal Block w/Compression Screws Terminals Accept Up To 14 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L
Weight 10 oz
Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2
general Technical Specifications Dimensions
Fire Alarm
14
edco™ HSP Series120 VAC Heavy Duty 120 Volt ACThe Edco HSP Series is an advanced three-stage hybrid, solid state power-
line protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Features ■ Fast response time
■ Failure indicator
■ Power line tracking
■ Filtering
■ Polycarbonite NEMA 4X enclosure (HSP121A)
■ Three-stage hybrid design
■ Replaceable fuse
■ 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A)
■ 5 year warranty
GND
N
AC
GND
N
AC
3/4" Conduit Fitting 3/4" Conduit Fitting
1/2" Conduit Fitting 1/2" Conduit Fitting
Mounting – HSP121AHoles 3/16" Dia.
eDCO HSP121BT-1ru
eDCO HSP121A
Mounting – HSP121BT-1RUHoles 3/16" Dia.
Light On – NormalLight Off – Requires Service
PowerSure™ emC-240B120/240 VAC Heavy Duty (Parallel)The PowerSure EMC-240B surge suppressor is designed to protect AC
distribution panel circuits or 120V power supplies feeding sensitive
electronic equipment. Electrically, the unit incorporates MOV and thermal
fusing technology. The PowerSure EMC-240B is designed to be installed in
parallel on standard single phase 120/240 VAC (3W + G) or single phase
120 VAC (2W + G) circuits.
Features ■ Fast response time
■ 40 kA per phase capacity
■ Failsafe and fused
■ Operational status indicators
■ ANSI/UL 1449 Third Edition Type 2
■ 5 year warranty
general Technical SpecificationsMaximum Operating Voltage 120/240 VAC
I Nominal (In) 3 kA
Operating Current NA, Parallel
Total Peak Surge Current 80 kA (8 x 20 µs)
Operating Frequency 47–63 Hz
EMI Attenuation (100 kHz to 100 MHz) > 40 dB
SPD Technology Metal Oxide Varistors (MOVs)
Modes Of Protection Line-to-Line Line-to-Neutral
Status Indication Power On & MOVs Functional
Connection Type Wire Leads
Operating Temperature -40°C to +85°C
Dimensions (Inches) 4.6H x 2.2W x 2.8L
Weight 13.5 oz
Certification ANSI/UL 1449 Third Edition, Type 2
Fire Alarm
15
installation
L
N120 V
Ground
EMC-240B
BlackBlackWhiteGreen
N L
EMC-240B
BlackBlackWhiteGreen
120 V
120 V
Ground
L1
240 V
L2
N
L2 N L1
4.5
2.8 2.2
18
120 VAC Service 120/240 VAC Service
EMC-240B
BlackBlackWhiteGreen
240 V
240 V
L1
240 V
L2
GND
L2 GND L1
240 V AC Service
Caution:Installation and service should be performed by qualified electricians only.
Before installing EMC, remove all electrical power from circuits.
Connect on load side of main breakers. Use two dedicated 30A circuit breakers.
mechanical
2.8" 2.2"
4.5"
18"
edco™ FAS-1 and FAS-2 SeriesOne- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high exposure applications. These products were
specifically designed to meet multiple low voltage protection applications in the
fire and security industries.
Features ■ Lightning protection for low voltage
■ Data/signal lines
■ Multi stage protection
■ Common mode and differential protection mode
■ Automatic recovery
■ 5 year warranty
Maximum Operating Voltage 15, 24, 36, 52 VDC
Clamping Voltage 18, 33, 43, 60 VDC
Operating Current 2.5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology GDT, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L
Weight FAS-1 = 3.5 oz FAS-2 = 7 oz
Certification UL 497B
FAS-1-018 HC (One-pair) 12VDC Use FAS-2-018 HC (Two-pair)
FAS-1-033 HC (One-pair) 24VDC Use FAS-2-033 HC (Two-pair)
FAS-1-043 HC (One-pair) 24VAC Use FAS-2-043 HC (Two-pair)
FAS-1-060 HC (One-pair)* 48V Systems Use FAS-2-060 HC (Two-pair)*
* Not UL listed
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes.
general Technical Specifications Ordering informationinstallation
< 3
Unprotected Or Field Side
Protected Equipment
Ground Lug
10–14 AWG
Equi
p. Line
16
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Fire Alarm
Fire Alarm
17
Features ■ LED indicator
■ Fast response time
■ Thermal fuse
■ L-G, L-N, & N-G protection
■ Compact size
■ Liquid tight conduit fitting
■ ANSI/UL 1449 Third Edition Type 2
■ 5 year warranty
PowerSure™ FAS-120ACMedium Duty 120 VAC — Single PhaseThe PowerSure FAS-120AC surge suppressor is designed to protect AC distribution
panel circuits or 120V power supplies feeding sensitive electronic equipment.
Electrically the unit incorporates MOV and thermal fusing technology. This device is
designed to be installed in parallel on standard single phase 120 VAC
(L, N, G) circuits.
Installation can be close-nipple up to a distribution panel/circuit or hardwired in
parallel up to power supply input terminal screws. Be sure to dress leads as short
as possible.
general Technical Specifications
Part Number PowerSure FAS-120AC
Maximum Operating Voltage 120 VAC
SPD Location Type Type 2
I-Nominal (In) 3 kA
Operating Current NA
Peak Surge Current 6.5 kA/Mode, 13 kA/Phase, 15.5 kA/Total
Operating Frequency 47–63 Hz
EMI Attenuation NA
SPD Technology MOVs
Modes of Protection L-N, L-G, N-G
Status Indication Power On & MOVs Functional
Connection Type Wire Leads
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2.5H x 1.5W x 3.0L
Weight 4 oz
Certification ANSI/UL 1449 Third Edition, Type 2
mounting
1.5"
Ø0.1860
2.5"
3"
Caution:This product should be installed and serviced by qualified service technicians or personnel only.
Remove power before installation or service.
18
Burglar 12VDC
Protecting Burglar Alarm Systems Application Drawings
Commercial
residential
edco™ FAS-1 and FAS-2 SeriesOne- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features ■ Lightning protection for low voltage
■ Data/signal lines
■ Multi stage protection
■ Common mode and differential protection mode
■ Automatic recovery
■ 5 year warranty
Maximum Operating Voltage 15, 24, 36, 52 VDC
Clamping Voltage 18, 33, 43, 60 VDC
Operating Current 2.5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology GDT, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L
Weight FAS-1 = 3.5 oz FAS-2 = 7 oz
Certification UL 497B
FAS-1-018 HC (One-pair) 12VDC Use FAS-2-018 HC (Two-pair)
FAS-1-033 HC (One-pair) 24VDC Use FAS-2-033 HC (Two-pair)
FAS-1-043 HC (One-pair) 24VAC Use FAS-2-043 HC (Two-pair)
FAS-1-060 HC (One-pair)* 48V Systems Use FAS-2-060 HC (Two-pair)*
*Not UL listed
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes.
general Technical Specifications Ordering informationinstallation
< 3
Unprotected Or Field Side
Protected Equipment
Ground Lug
10–14 AWG
Equi
p. Line
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
19
Burglar 12VDC
Burglar 12VDC
20
islatrol™ SP-6TVNPlug-in Surge Protection (Active Tracking™ Filter)The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device
that plugs into a standard duplex receptacle. It features uniquely designed
repositionable outlets and protects against damaging power disturbances
traveling through your wiring into your electrical outlets.
Features ■ Plugs into standard 120V, 15A
electrical outlet
■ Total peak surge current capacity of 39 kA
■ Cables for telephone, video, and data connectors included
■ Repositionable outlets rotate to accommodate available space
■ Perfect for tight spaces, behind furniture
and appliances
■ Intelligent monitoring against improper wiring/grounding
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ 5 year warranty
general Technical Specifications
AC Power Protection
Nominal Operating Voltage 120 VAC, Single Phase
Operating Voltage Range 120 VAC +/- 10%
Operating Frequency Range 47–63 Hz
Rated Output 15A
ANSI/IEEE C62.41 Category Category A & B
Connection Type (6) 5-15R Receptacles and 5-15P Plug
Phase Configuration 2 Wire + Gnd
Size 7.5 x 4.75 x 1.75 (Inches)
Enclosure High Impact Plastic
Weight 2.0 lbs (0.9 kgs)
Modes Of Protection L – N, L – G, N – G
Indication Of Suppression Status Status Indicator
Response Time < .5 ns Normal Mode
Certification ANSI/UL 1449 Third Edition Type 3
maximum Continuous Operating Voltage (mCOV)
Line To Neutral 130 VAC
Peak Surge Current (8 x 20 ms)
Line To Neutral 13 kA
Line To Ground 13 kA
Neutral To Ground 13 kA
Total 39 kA
ANSi/ieee C62.41 Cat A ringwave (6 kV, 200A, 100 kHz)
Normal Mode 265V
Common Mode 290V
ANSi/ieee C62.41 Cat B ringwave (6 kV, 500A, 100 kHz)
Normal Mode 275V
Common Mode 290V
Frequency response
Normal Mode 60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz
Common Mode 40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz
low Voltage Protection Video 1 & 2 Phone Network
Connection Type Type “F” Type RJ-11 Type RJ-45
Cables Provided 6 (2x) Type “F” RJ-11 Male RJ-45 Male 6' Ends 6' Ends Ends
Peak Surge Current 5 kA 2 kA 3 kA (8 x 20 µs) (10 x 1000 µs) (8 x 20 µs)
Capacitance <12 pf <50 pf <70 pf
Protection Level L-G T-R, T-G, R-G L-G (8 Lines)
Clamping Voltage (DC) 145 V 270–350 V 30 V
Attenuation 1 dB @ 2 Ghz N/A N/A
rePOSiTiONABle OuTleTS
Maximum Operating Voltage 12, 24, 43, 52, 180, 220, & 220 VDC
Clamping Voltage 15, 30, 50, 60, 200, 270 & 300 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 µs T & R to Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode w/ Series PTC
Connection Type Terminal Block w/Compression Lugs In/ RJ Connector Out
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1H x 2W x 2L
Weight 2 oz
Certifications UL 497A, CUL
Ordering informationFAS-TEL-060T Digital Phone
FAS-TEL-200T Analog Phone/Fax/Modem
FAS-31XT Alarm System Phone
FAS-TEL-DSL DSL
Features ■ <1 nanosecond response time
■ Solid-state silicon breakover technology
■ Low capacitance
■ Over current protection
■ UL 497A listed
■ Line-to-line protection
■ Line-to-ground protection
■ Polyswitch resettable fuses — PTCs
■ 5 year warranty
edco™ FAS-Tel and FAS-31XTRJ11/RJ31X Telephone Protection
The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak and
fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a standard
RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
general Technical Specifications
21
Burglar 12VDC
270 Volts
300 Volts
0 1 5
0 3 0
0 5 0
0 6 0
2 0 0
15 Volts
30 Volts
50 Volts
60 Volts
200 Volts
ClampingVoltage F A S - T E L - T
F A S - T E L - D S L
F A S - 3 1 X T
How To Specify The Appropriate model
Burglar 12VDC
22
general Technical Specifications
edco™ Ter SeriesSingle-Pair Medium Duty Low Voltage Zone/Horn/Strobe/DataThe Edco TER surge suppressor directly installs onto electronic circuit wiring
terminal screws. This close proximity preserves Edco TER’s response time,
clamping level and ground reference by elimi nating lead lengths. The Edco
TER’s miniature size fits directly inside fire or security panels, CCTV housings
and other system electronic enclosures. These features maximize surge
suppression performance while reducing hardware and labor costs to install.
Features ■ Fits Euro style and barrier strip terminals
■ Automatic recovery
■ Single-pair protection
■ High energy silicon avalanche technology
■ UL 497B listed
■ Operating current > 2 Amps
■ Compact size: 1.3" x 0.4" x 2" (HxWxL)
■ 5 year warranty
Maximum Operating Voltage 15, 30, 40 VDC
Clamping Voltage 18, 33, 43 VDC
Operating Current 0.09A
Peak Surge Current (10 x 1000 µs) 018 = 215A, 033 = 108A, 043 = 81A
Frequency Range 0 to 20 MHz
Insertion Loss <0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.3H x 0.4W x 2.0L
Weight 0.6 oz
Certification UL 497B
Fits in Series With Circuits Wires At The Terminal Screws
Zone, Buss, Loop, Data, Receive, Bell, Horn, Strobe, Pan/Tilt & CCTV
TER-018 (For 12 VDC Systems)
TER-033 (For 24 VDC Systems)
TER-043 (For 24 VDC Systems)
general Technical Specifications Ordering information
edco™ PC2-Tel Two-Line Telephone Protection (Modular)The Edco PC2-TEL is a solid state, two-line telephone interface protector
module. This unit is specifically designed to protect both phone lines required by
commercial security panels.
Features ■ Tip-to-ring protection
■ Tip- and ring-to-ground protection
■ Over-current protection
■ Resettable solid state fuses — PTCs
■ UL listed 497A
■ Requires PCB1B base
■ PC642PTU (Pass Thru Unit) available for troubleshooting
■ 5 year warrantyeDCO PCB1B BASe SOlD SePArATely
Maximum Operating Voltage 250 VDC
Clamping Voltage 270 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 T & R To Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Series PTC and Silicon Avalanche Diode (SAD)
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (PC2TEL + PCB1B Base)
Weight 1 oz
Certifications UL 497A, CUL
Protecting Access Control Systems Application Drawing
AccessControl
Panel
RS-485/RS-422 Circuit
Electric Strike orMaglock Circuit
Card Reader (Wiegand)
Circuit for Device Outside of Building
Door LockPower Supply
Dial-UpCom
LAN/WAN
AC PowerGate Position Switch
Gate Lock/Control
To Head-End or Other
Control Panels
SP 1
SP 8
SP 7
SP 1 SP 5 SP 6
SP 2
SP 3
SP 4
SP 5
SP 3
SP 4
SP 2
SP 1 .... HSP-121BT1RUSP 2 .... PC642C-008LC*SP 3 .... EL-EDSSP 4 .... 5W8-30*SP 5 .... FAS-1-xxxHCSP 6 .... FAS-2-xxxHCSP 7 .... LCDP-xxxSP 8 .... FAS-31XT
*Needs PCB1B Base
Legend
Access Control
23
24
Access Control
The diagram below illustrates the proper installation of the Edco EL-EDS. For each maglock or electric strike circuit, you will need to install a suppressor (1) across the relay contacts and (2) across the leads connected to the lock solenoid (locate as close as possible to the solenoid). The suppressor wires can be installed without regard to polarity. If your package does not contain two (2) devices, contact your distributor.
installation
edco™ el-eDSElectric Door Suppressor The Edco EL-EDS suppressor kit is intended for installation with electrical
switching devices that are connected through a relay contact on typical access
control panels.
The Edco EL-EDS protects against electrical anomalies (transients) that are
generated as a result of the collapsing electrical field of an electromagnetic
switching device (maglock or electric strike). The Edco EL-EDS provides
protection for both relay contacts and control panel.
Maximum Operating Voltage 52 VDC
Clamping Voltage 56 VDC
Operating Current NA
Peak Surge Current 500 A
Frequency Range 0 to 20 MHz
Insertion Loss <0.1 dB at 20 MHz
SPD Technology SAD w/Filtering Capacitor
Connection Type Wire Leads
Operating Temperature -40˚C 10 +85˚C
Dimensions (Inches) 8 L
Weight 1 oz
Warranty 5 years
general Technical Specifications
Features ■ <1 Electromagnetic protection
■ 2 devices per package
■ Relay contact and control panel protection
■ 5 year warranty
edco™ 5W8-30 Two-Pair Data/Signal Line Power The Edco 5W8-30 is an access control protection module designed for
typical Wiegand outputs for access devices. This is a 5-wire module that
accommodates low voltage data lines for 5 VDC circuits. Fifth wire power
protection will allow up to 24 VDC.
In addition, sneak and fault currents are mitigated with resettable fuses
(PTCs). The PTCs increase resistance several orders of magnitude when over-
currents exceed safe levels. A normal state resumes when over-currents are
removed. The ability to self restore in this manner significantly increases
suppressor performance and survivability.
Features ■ Automatic recovery
■ Fast response time
■ Resettable fusing — PTCs
■ Plug-in module
■ Data and power protection combined
■ Sneak/fault current protection (data only)
■ Silicon avalanche technology
■ Requires Edco PCB1B base
■ PC462 PTU (Pass Thru Unit) available for troubleshooting
■ 5 year warranty
Maximum Operating Voltage 5 VDC (Data) & 24 VDC (Power)
Clamping Voltage 8 VDC (Data) & 30 VDC (Power)
Operating Current 0.15A
Peak Surge Current Data = 125A (10 x 1000 µs) Power = 500 A (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.15dB at 20 MHz
SPD Technology MOV, SAD, w/ Series PTC
Connection Type Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (5W8-30 + PCB1B Base)
Weight 1 oz
general Technical Specifications installation
eDCO PCB1B BASe SOlD SePArATely
Note: The hybrid design of this product includes series resistance. Do not use this device if data pairs are capable of continuously supplying more than 150 milliamperes.
Ground Terminal To Building-Approved Ground (Preferably AC Power Safety Ground)
DC Power — T-Tap PositiveCommon Wire Here
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
25
Access Control
26
Access Control
Maximum Operating Voltage 12, 24, 43, 52, 180, 220, & 220 VDC
Clamping Voltage 15, 30, 50, 60, 200, 270 & 300 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 µs T & R to Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode w/ Series PTC
Connection Type Terminal Block w/Compression Lugs In/ RJ Connector Out
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1H x 2W x 2L
Weight 2 oz
Certifications UL 497A, CUL
Ordering informationFAS-TEL-060T Digital Phone
FAS-TEL-200T Analog Phone/Fax/Modem
FAS-31XT Alarm System Phone
FAS-TEL-DSL DSL
Features ■ <1 nanosecond response time
■ Solid-state silicon breakover technology
■ Low capacitance
■ Over current protection
■ UL 497A listed
■ Line-to-line protection
■ Line-to-ground protection
■ Polyswitch resettable fuses — PTCs
■ 5 year warranty
edco™ FAS-Tel and FAS-31XTRJ11/RJ31X Telephone Protection
The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak and
fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a standard
RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
general Technical Specifications How To Specify The Appropriate model
270 Volts
300 Volts
0 1 5
0 3 0
0 5 0
0 6 0
2 0 0
15 Volts
30 Volts
50 Volts
60 Volts
200 Volts
ClampingVoltage F A S - T E L - T
F A S - T E L - D S L
F A S - 3 1 X T
edco™ HSP Series120 VAC Heavy Duty 120 Volt ACThe Edco HSP Series is an advanced three-stage hybrid, solid state, power-
line protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Maximum Operating Voltage 120 VAC
Clamping Voltage 325 VAC
Operating Current 15A
I-Nominal (In) 3 kA
Total Peak Surge Current 39 kA (8 x 20 µs)
Operating Frequency 47–63 Hz
EMI Attenuation (100 kHz to 100 MHz) > 40 dB
SPD Technology Metal Oxide Varistors (MOVs) w/ L-C Filter
Modes Of Protection Line-to-Neutral, Line-to-Ground, Neutral-to-Ground
Status Indication Power On & MOVs functional
Connection Type 3 Position, 20A Terminal Block w/Compression Screws Terminals Accept Up To 14 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L
Weight 10 oz
Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2
general Technical Specifications Dimensions
Mounting – HSP121BT-1RUHoles 3/16" Dia.
Light On – NormalLight Off – Requires Service
Features ■ Fast response time
■ Failure indicator
■ Power line tracking
■ Filtering
■ Polycarbonite NEMA 4X enclosure (HSP121A)
■ Three-stage hybrid design
■ Replaceable fuse
■ 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A)
■ 5 year warranty
27
Access Control
GND
N
AC
GND
N
AC
3/4" Conduit Fitting 3/4" Conduit Fitting
1/2" Conduit Fitting 1/2" Conduit Fitting
Mounting – HSP121AHoles 3/16" Dia.
eDCO HSP121BT-1ru
eDCO HSP121A
28
Access Control
edco™ PC642 Series Zone/Loop/DataThe Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance by several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
performance and survivability.
The Edco PC642 Series card edge module is gold plated, double sided, and is
designed to mate with the Edco PCB1B gold-plated female terminal connector.
When snapped together, the data circuits “pass thru” the protector in a serial
fashion from the four “Field Side” terminals to the four “Electronics Side”
terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building-
Approved Ground per Edco Technical Bulletin # 2015.
Features ■ Three-stage hybrid protection
■ Sneak/fault current protection
■ Resettable fusing — PTCs
■ Low capacitance option
■ Plug-in module
■ Fast response time
■ Requires Edco PCB1B base
■ Order PC642PTU — an invaluable troubleshooting tool
■ 5 year warranty
eDCO PCB1B BASe SOlD SePArATely
OPTiON:DiN rAil KiT AVAilABleOrDer PArT # 11604KiT-PC
general Technical SpecificationsMaximum Operating Voltage 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC
Clamping Voltage 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC
Operating Current 0.15A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology GDT, SAD, w/Series PTC
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG
Operating Temperature -40°C to +85°C
Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base)
Weight 1 oz
Certification UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 milliamperes continuously.
Terminal Assignments
PCB1B:
Unprotected Pair 2
Unprotected Pair 1
Protected Pair 2
Protected Pair 1
Keying Pin
Even TerminalsOdd Terminals
Field SideElectronics Side
9
7
5
3
1
10
8
6
4
2
1.0
{ }
}{ 2.125" 2.4"
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Ordering information
PC642
PCB1B
APPliCATiON:
RS485, RS422: PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
RS232: PC642C-020 & PCB1B
E-Net, 10 Base T: PC642C-030LC & PCB1B
4–20 ma: PC642C-036 & PCB1B
How To Specify The Appropriate model
-
Voltage Clamp
60 Volts50 Volts43 Volts36 Volts30 Volts
15 Volts8 Volts
2 0 0
PC642C
20 Volts
**200 Volts0 6 0 0 5 0 0 4 3
0 3 0 0 2 0
0 3 6
0 1 5 0 0 8
no suffixstage 2 clampeach line-to-groundstage 2 clampline-to-line only
stage 2 clamp line-to-lineand each line to ground
D
Xlow capacitance option stage2 clamp line-to-line and eachline to ground
**Not UL Listed
LC
general Technical Specifications
Maximum Operating Voltage 5, 12, 24, 48, 65 VDC
Clamping Voltage 8, 15, 30, 60, 75 VDC
Operating Current 1.5A
Peak Surge Current (10 x 1000 µs) 008 = 125A, 015 = 72A, 030 = 22A, 060 = 18A, POE*=15A
Frequency Range 0 to 100 MHz
Insertion Loss < 0.1 dB at 50 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type RJ-45 Jacks
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.0H x 2.5W x 4.25L
Weight 3 oz
Certification UL 497B
* LCDP-POE is not UL certified
The user equipment plugs into the LCDP’s equipment (protected) side, and the LCDP’s line (unprotected) side is connected to the incoming line. All 8 conductors are protected. The green ground wire must be bonded to the protected equipment power ground (third wire, green wire safety ground). Do not add length to the ground wire, since it must be kept as short as possible.
Ordering information
Model Clamping Voltage
LCDP-008 8 Volts
LCDP-015 15 Volts
LCDP-030 30 Volts
LCDP-060 60 Volts
LCDP-POE* 75 Volts
installation
Features ■ <1 nanosecond response time
■ Line-to-line protection
■ Low capacitance
■ RJ-45/4 pair protection (8 wire)
■ Silicon avalanche design
■ Line-to-ground protection
■ 5 year warranty
edco™ lCDPData Circuit ProtectionThe Edco LCDP Series is designed to conveniently protect 8 wire, low voltage, data
circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes
silicon avalanche (solid-state) suppression technology and exhibits very low
capacitance to accommodate high data rates. This unit supports high-speed data
rates of over 100 Mbps.
Access Control
29
Communications
30
edco™ FAS-1 and FAS-2 SeriesOne- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features ■ Lightning protection for low voltage
■ Data/signal lines
■ Multi stage protection
■ Common mode and differential protection mode
■ Automatic recovery
■ 5 year warranty
Maximum Operating Voltage 15, 24, 36, 52 VDC
Clamping Voltage 18, 33, 43, 60 VDC
Operating Current 2.5A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 10 MHz
Insertion Loss < 0.1 dB at 10 MHz
SPD Technology GDT, SAD, w/Series Inductor
Connection Type Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG
Operating Temperature -40 C to +85 C
Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L
Weight FAS-1 = 3.5 oz FAS-2 = 7 oz
Certification UL 497B
FAS-1-018 HC (One-pair) 12VDC Use FAS-2-018 HC (Two-pair)
FAS-1-033 HC (One-pair) 24VDC Use FAS-2-033 HC (Two-pair)
FAS-1-043 HC (One-pair) 24VAC Use FAS-2-043 HC (Two-pair)
FAS-1-060 HC (One-pair)* 48V Systems Use FAS-2-060 HC (Two-pair)*
*Not UL listed
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes.
general Technical Specifications Ordering informationinstallation
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
< 3
Unprotected Or Field Side
Protected Equipment
Ground Lug
10–14 AWG
Equi
p. Line
Communications
31
Maximum Nominal Surge Peak Current Typ Maximum Nominal Part Peak Signal Breakdown 1p 10 x 1000 µs 8 x 20 µs Cap Continuous Series Number Voltage Voltage Current Waveform (pf) Current (ma) Resistance
DRS-008 6 8 >100 10 kA 1500 150 5 Ohms
DRS-015 12 15 >100 10 kA 1500 150 5 Ohms
DRS-232 15 22 >100 10 kA 1500 150 5 Ohms
DRS-030 24 30 >100 10 kA 1500 150 5 Ohms
DRS-036 30 36 >100 10 kA 1500 150 5 Ohms
DRS-043 35 43 >100 10 kA 1500 150 5 Ohms
DRS-050 43 50 >100 10 kA 1500 150 5 Ohms
DRS-060 52 60 >100 10 kA 1500 150 5 Ohms
*DRS-175 200 250 >10 8 kA 1500 150 5 Ohms
**DRS-130 170 200 >10 8 kA 1500 5000 None
*Not UL 4978 Listed
**Warning!! DRS-130RMS is for discrete signal use only. Do not use DRS-130RMS on 120 VAC power lines. This unit is a non-hybrid, MOV design, rated above 5A operational current and can withstand greater than eight occurrences of a 10 kA (8 x 20 µs) waveform, and greater than 1,000 occurrences of a 200A 10 x 1000 µs waveform.
general Technical Specifications Dimensional Diagrams
Features ■ Low-voltage data surge protection
■ Three-stage hybrid protection
■ Sneak/fault current protection with resettable fuses—PTCs
■ Low profile packaging
■ UL 497B listed
■ Easy installation
■ Fits standard 35 mm DIN rail
■ Fast response time < 1 nanosecond
■ 5 year warranty
edco™ DrS (DC) SeriesDIN Rail Protection The Edco DRS (DC) Series is a DIN rail mountable, single-pair surge suppression
module implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components. In
addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs
increase resistance several orders of magnitude when over-currents exceed safe
levels. A normal state resumes when over-currents are removed. The ability
to self-restore in this manner significantly increases suppressor performance
and survivability.
The Edco DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail.
There are three “Field Side” and three “Electronics Side” screw terminals. One
is reserved for a shield. Three electrically tied ground terminals are provided for
grounding the Edco DRS (DC) Series unit to Building-Approved Ground. Shield is
isolated from ground.
For a 2-terminal version without a shield, order the Edco DRS-XXX-2.
DrS-XXX-2 (2 Terminal Version)
DrS-XXX
edco™ CATV-DFHigh Frequency Coax Protector — F-TypeThe Edco CATV–DF surge protectors are designed to protect sensitive electronic
equipment from damage due to excessive voltage or currents generated by
lightning or static buildup.
Applications include direct broadcast satellite systems, HDTV, and cable modems.
The Edco CATV–DF offers low signal loss at frequencies up to 2 gigahertz.
Incorporates GDT (gas discharge tube) technology.
Maximum Operating Voltage 25 VDC
Clamping Voltage 150 VDC (Spark Over Voltage)
Operating Current 1A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 2 GHz
Insertion Loss < 1.0 dB at 1 GHz < 2.0 dB at 2 GHz
SPD Technology Gas Discharge Tube (GDT)
Connection Type Type F Female
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 2.5W x 4L
Weight 3 oz
Maximum Operating Voltage 130 VDC
Clamping Voltage 150 VDC (DC Spark Over Voltage)
Operating Current 1A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 4 GHz
Insertion Loss < 0.5 dB 2 to 3 GHz
SPD Technology Gas Discharge Tube (GDT)
Connection Type Female N-Type
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x .875W x 2.5L
Weight 4 oz
general Technical Specifications
Features ■ Automatic recovery
■ Low insertion loss
■ Shielded case
■ Easily installed
■ 5 year warranty
general Technical Specifications
edco™ CX-HFNHigh Frequency Coax Protector — N-TypeThe Edco CX-HFN surge protectors are designed to protect sensitive
electronic equipment from damage due to excessive voltage or currents
generated by lightning or static buildup.
The Edco CX-HFN offers low signal loss at frequencies up to 3 gigahertz.
The Edco CX-HFN accommodates both bulkhead mount and stud mount.
The input and output connections are interchangeable.
Ordering informationCX-HFN-FM Female to Male
CX-HFN-FF Female to Female
Communications
32
Maximum Operating Voltage 12, 24, 42, 12, 35 VDC
Clamping Voltage 15, 30, 48, 15, 56 VDC
Operating Current 2A
Peak Surge Current 015 =125A, (10 x 1000 µs) 030 = 71A, 048 = 45A, CLN = 125A, SPK = 500A, 8 x 20 µs
Frequency Range 0 to 20 MHz
Insertion loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD), OPX-SPK Model Uses MOV
Connection Type Clip
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 0.375W x 2.0L
Weight 1 oz
Certification UL 497B
edco™ OPX SeriesIntercom/Speaker Punch Block Protection (Parallel) Medium Exposure ApplicationsThe Edco OPX Series surge protectors are specifically designed for medium-
exposure applications. Thus, the protectors can be used on pairs inside a building
or leaving the build ing, in conduit up to 500 feet. These protectors are intended
to be used in conjunction with the Edco MGB Ground Rail and a standard MI-50
Punch Down Block.
The Edco OPX Series offers several, distinct advan tages over other current
technologies. Among the advantages are low cost, no series resis tance, and
durable solid-state construction.
general Technical Specifications
Test Points
MI-50 Block
installation
Features ■ Over-current protection
■ Replaces bridging clips on MI-50 block
■ UL 497B listed
■ Utilizes MGB grounding rail
■ Test point accessible
■ 5 year warranty
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Communications
33
0 1 5
0 3 0
0 4 8
C L N
S P K
15 Volts
30 Volts
48 Volts
15 Volts (Call-In Circuit)
56 Volts (Speaker Circuit)
ClampingVoltage
O P X
How To Specify The Appropriate model
Communications
34
Features ■ Over current protection
■ Replaces bridging clips on M1-50 bock
■ UL 497B listed
■ Utilizes MGB grounding rail
■ Test point accessible
■ 5 year warranty
Maximum Operating Voltage 12, 56 VDC
Clamping Voltage 21, 70 VDC
Operating Current 0.15A
Peak Surge Current PBCLN = 0.2 kA, PBSPK = 0.5 kA (10 x 1000 µs)
Frequency Range 0 to 20 MHz
SPD Technology PBCLN = SAD w/Series PTC, PBSPK = MOV w/Series PTC
Insertion Loss < 0.1 dB at 20 MHz
Connection Type Clip
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 0.4W x 2.8L
Weight 1 oz
Certification UL 497B
Ordering informationPBCLN Call-In Circuit
PBSPK Speaker Circuit
Test Points
MI-50 Block
See Technical Bulletin # 2017
Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continu ously supplying more than 150 mA.
general Technical Specifications installation
TTA-2: Test Point Plug Available
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
edco™ PB SeriesIntercom/Speaker Punch Block Protection (Series)The Edco PB modules are solid-state protectors for intercom extension pairs.
As a new alternative to the “OPX,” the standard EDCO intercom protector, the PB
adds fusing and a new component layout. These hybrid protectors are intended
to be used in conjunction with the EDCO MGB ground rail and a standard MI-50
punch down block. The PB modules feature solid-state resettable fuses (PTCs)
between the protected equipment and the over voltage clamping components.
This unique design prevents problems with “All-Call” in the event of catastrophic
protector failure.
Patented Technology
edco™ H SeriesTelecom/Punch Block Protection Advanced Ultra High Speed TechnologyThe Edco H Series modules are ultra high speed, fused, solid state, secondary
protectors for KEY/PABX systems. The units are available in three different
clamping voltages. The Edco H Series is constructed with solid state silicon
foldback technology, polyswitch resettable fuses — PTCs — and failure fuses.
These protection modules are intended to be used in conjunction with proper
primary protectors (UL 497A). The protective elements switch from the normal
high-impedance state to a low-impedance state upon a detection of a surge,
then switch back to high impedance after the surge has passed. The Edco
H Series single-pair modules fit onto a standard Edco MI-50 split block and
replace bridging clips. In addition, these modules require the Edco MGB Ground
Rail for each Edco MI-50 block used.
Maximum Operating Voltage 50, 180, 230 VDC
Clamping Voltage 65, 200, 270 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 µs T & R to Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Breakover Device w/Series PTC
Connection Type Clip
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 0.4W x 2.8L
Weight 1 oz
Certifications UL 497A, CUL
Ordering informationHCO Central Office/Trunk
HAE Analog Extension
HDE Digital Extensions
MI-50 Block
Unprotected Side — Terminate Field Side Wiring Coming IntoBuilding On The “Unprotected Side”
general Technical Specifications installation
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Patented Technology
Communications
35
Communications
36
edco™ COHP SeriesData/Signal Line/Punch Block Protection High-Exposure ApplicationsThe Edco COHP modules are three-stage hybrid protectors for low-voltage data and
telecommunications applications. The modules address over-voltage transients with
gas tubes and silicon avalanche components. In addition, sneak and fault currents
are mitigated with resettable fuses (PTCs). Intended to be used on pairs without
the presence of ring ing voltage. The Edco COHP modules are designed for data and
control applications as an isolated loop circuit protector.
Features ■ Replaces bridging clips on MI-50 Block
■ <1 nanosecond response time
■ Line-to-line protection
■ Line-to-ground protection
■ Utilizes MGB grounding rail
■ Rugged, three electrode, gas tube, first stage
■ Silicon avalanche hybrid technology
■ Polyswitch resettable fusing — PTCs
■ 5 year warranty
edco™ mgB ground railFits Standard 66MI-50 Punch Down Blocks Split Block VariationsThe Edco MGB Ground Rail — designed to fit standard 66MI-50 Punch Down Blocks.
Allows Edco’s H Series, COHP, OPX, PB Series and other similar surge suppressors to
access ground when snapped onto the 66MI-50 Punch Down Block. The Standard
66MI-50 Block is capable of accommodating up to 25 Edco surge suppressors.
MI-50 Block
Edco Recommends A 10AWG Wire To
Building-Approved Ground —Keep Short
Protected Unprotected
U.S. Patent No. 4,703,983
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Maximum Operating Voltage 6, 12, 20, 24,
43, 52 VDC
Clamping Voltage 8, 15, 20, 30, 50, 60 VDC
Operating Current 0.15A
Peak Surge Current 10 kA (8 x 20 µs)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology GDT, SAD, w/ Series PTC
Connection Type Clip
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 0.4W x 2.8L
Weight 1 oz
Certification UL 497B
Model Clamping Voltage
COHP-008 8 Volts
COHP-015 15 Volts
COHP-020 20 Volts
COHP-030 30 Volts
COHP-050 50 Volts
COHP-060 60 Volts
general Technical Specifications Ordering information
Features ■ <1 nanosecond response time
■ Solid-state silicon breakover technology
■ Low capacitance
■ Over current protection
■ UL 497A listed
■ Line-to-line protection
■ Line-to-ground protection
■ Polyswitch resettable fuses — PTCs
■ 5 year warranty
Maximum Operating Voltage 12, 24, 43, 52, 180, 220, & 220 VDC
Clamping Voltage 15, 30, 50, 60, 200, 270 & 300 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 µs T & R to Ground)
Frequency Range 0 to 20 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode w/ Series PTC
Connection Type Terminal Block w/Compression Lugs In/ RJ Connector Out
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1H x 2W x 2L
Weight 2 oz
Certifications UL 497A, CUL
Ordering informationFAS-TEL-060T Digital Phone
FAS-TEL-200T Analog Phone/Fax/Modem
FAS-31XT Alarm System Phone
FAS-TEL-DSL DSL
general Technical Specifications
edco™ FAS-Tel and FAS-31XTRJ11/RJ31X Telephone ProtectionThe Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak
and fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a
standard RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
Communications
37
How To Specify The Appropriate model
270 Volts
300 Volts
0 1 5
0 3 0
0 5 0
0 6 0
2 0 0
15 Volts
30 Volts
50 Volts
60 Volts
200 Volts
ClampingVoltage F A S - T E L - T
F A S - T E L - D S L
F A S - 3 1 X T
Communications
38
Maximum Operating Voltage 5, 12, 24, 48, 65 VDC
Clamping Voltage 8, 15, 30, 60, 75 VDC
Operating Current 1.5A
Peak Surge Current (10 x 1000 µs) 008 = 125A, 015 = 72A, 030 = 22A, 060 = 18A, POE*=15A
Frequency Range 0 to 100 MHz
Insertion Loss < 0.1 dB at 50 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type RJ-45 Jacks
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.0H x 2.5W x 4.25L
Weight 3 oz
Certification UL 497B (*except LCDP-POE)
edco™ lCDPData Circuit ProtectionThe Edco LCDP Series is designed to conveniently protect 8 wire, low-voltage data circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes silicon avalanche (solid-state) suppression technology and exhibits very low capacitance to accommodate high data rates. This unit supports high-speed data rates of over 100 Mbps.
edco™ rm-CAT6-POe SeriesMulti-Channel RackmountThe Edco RM-CAT6-POE Series is a modular, high speed, data-line protector
that utilizes a three-stage hybrid design technology. This unit addresses high-
energy voltage transients that can damage expensive computer equipment.
Ideal for network switches and hubs, the Edco RM-CAT6-POE Series is easily
mounted in close proximity to the protected equipment.
general Technical Specifications
Features ■ Exceeds Category 6 transmission values
■ Compact 1U rack size
■ Replaceable surge modules
■ Low insertion loss
■ Offered in 16 or 48 channel protection*
■ Three-stage hybrid
■ Meets POE requirements
■ 1 year warranty
*Other configurations available. Consult factory.
Maximum Operating Voltage 57 VDC
Clamping Voltage 68 VDC
Frequency Range 0-250 MHz
Operating Current 0.15A
SPD Technology GDT, SAD, W/Series PTC
Modes of Protection Signal High-Low Signal High-Ground, Signal Low-Ground
Peak Surge Current 10 kA (8 x 20 µs)
Insertion Loss <0.1dB
VSWR <1.2
Operating Humidity 0-95% Non-Condensing
Operating Temperature -40°C to +85°C
Input Connection Type RJ-45
Output Connection Type RJ-45
Mounting Rackmount
Enclosure Type Painted Steel
Dimensions 1.75Hx19Wx6.3D
Weight 5.5 lbs.
Features ■ <1 nanosecond response time
■ Line-to-line protection
■ Low capacitance
■ RJ-45/4 pair protection (8 wire)
■ Silicon avalanche design
■ Line-to-ground protection
■ 5 year warranty
general Technical SpecificationsThe user equipment plugs into the LCDP’s equipment (protected) side, and the LCDP’s line (unprotected) side is connected to the incoming line. All 8 conductors are protected. The green ground wire must be bonded to the protected equipment power ground (third wire, green wire safety ground). Do not add length to the ground wire, since it must be kept as short as possible.
Ordering informationLCDP-008 8 Volts
LCDP-015 15 Volts
LCDP-030 30 Volts
LCDP-060 60 Volts
LCDP-POE 75 Volts
installation
mODel SHOWN 48 CAT6-POe
Communications
39
edco™ rJA-rJD SeriesRJ-45 Telephone/DataThe Edco RJA and Edco RJD Series are four-pair telephone/data-line protectors
that implement advanced, two stage, hybrid design. These units address
over voltage transients with silicon breakover devices, while sneak and fault
currents are mitigated with PTC technology, which consists of solid state
resettable fuses.
The Edco RJA and Edco RJD Series incorporate Edco RJ-45 female jacks in and
out. The Edco RJA voltage clamp is set for C.O. Trunks and analog telephone
extensions (with ring in voltage), and the Edco RJD voltage clamp is set for
digital extensions (no ring in voltage).
Features ■ <1 nanosecond response time
■ Solid-state resettable fuses — PTCs
■ Silicon breakover technology
■ Low capacitance
■ Line-to-line protection
■ Tip- and ring-to-ground protection
■ CAN/CSA C22.2, No. 226-92 compliant
■ UL 497A listed
■ 4 pair protection
■ 5 year warranty
general Technical Specifications
Maximum Operating Voltage 48, 220 VDC
Clamping Voltage 55, 280 VDC
Operating Current 0.15A
Peak Surge Current 200 A (10 x 1000 µs)
Frequency Range 0 to 50 MHz
Insertion Loss < 0.1 dB at 50 MHz
SPD Technology Silicon Breakover Devices w/Series PTC
Connection Type RJ-45 Jacks
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.0H x 2.5W x 4.25L
Weight 3 oz
Certifications UL 497A, CUL
Analog Phone RJA-45
Digital Phone RJD-45
Gnd.
Building-Approved
Ground
Ordering informationinstallation
The Edco RJA and Edco RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector.
Communications
40
edco™ TBlK AssemblyTerminating AssemblyThe Edco TBLK is a high-density assembly designed to house up to 12 or 25
individual Edco surge protec tion modules. Standard Edco H Series, COHP,
OPX, PB Series, and other similar modules (separately ordered) are suitable
for the Edco TBLK assembly. The Edco TBLK is capable of terminating solid or
strand ed 26 to 14 AWG wire using compression terminal screws.
edco™ CAT6-5POe Series CAT6/CAT5 Power Over EthernetThe Edco CAT6-5POE Series is designed to work on Category 5 Power-Over-
Ethernet transmission lines as well as Category 6 applications. Ideal to protect
expensive equipment against surges and transients entering a building on
exposed transmission lines. Available in both female to female and male to
female RJ-45 connectors.
Features ■ Exceeds CAT5 & 6 transmission values
■ CAT5 POE compatible
■ CAT6 compatible
■ Applications up to 60 VDC @ 300 mA
■ 1 year warranty
Dimensions
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Operating Voltage 60 VDC
Clamping Voltage 65 VDC
Operating Current 300 mA
Peak Surge Current 60A (10 x 1000 µs)
Frequency Range 0 to 250 MHz
Insertion Loss < 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Connection Type RJ-45 Jacks
Operating Temperature -40°C to +85°C
Dimensions (Inches) 0.8H x 1.0W x 2.3L (FF) 0.8H x 1.0W x 3.0L (MF)
Weight 1 oz
RJ-45 (FF) CAT6-5POE-FF
RJ-45 (MF) CAT6-5POE-MF
general Technical Specifications Ordering information
Communications
41
1. Basic internal surge protection (standard)2. Plug-in hybrid surge protection
Tip/ring Or Data Protection1. Incoming C.O. lines use HCO 2. Analog extensions use HAE3. Digital extensions use HDE
AC Protection Options
To AC Building-Approved Ground
Cable Shield Ground
MGB Ground Rail
ChassisGround
MOD-12
HAE or HDE(One Per Extension)
66 Block
HCO(One Per CO TRUNK)
Existing Telco PrimaryProtection Demarc
CO TRUNKS
KSUHAE
HDE
Application Diagram
Features ■ 1 to 12 pair expansion
■ Replaceable single-pair protection modules
■ Punch down block (66 type)
■ Test points
■ Protective transparent cover
■ UL 1363 listed
■ 5 year warranty
edco™ mOD-12 Key SystemsThe Edco MOD-12 Tip/Ring protection for Key/PBX Systems. This innovative
design creates an automatic ground window, thus eliminating the problem of
ground potential difference.
Edco H Series Protector Modules readily snap onto the Edco MOD-12. Protection
is expandable from 1 to 12 pairs in single-pair increments and is field upgradable.
In addition, test points are provided on each pair.
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
Ordering informationMOD-12 Base Assembly
emerson Network Power. The global leader in enabling Business-Critical ContinuityTM.
AC PowerConnectivity
DC Power
HeadquartersSurge Protection100 Emerson ParkwayBinghamton, NY 13905T: 607-721-8840T: 800-288-6169F: 607-722-8713E: [email protected]
Embedded Computing
Monitoring
Outside PlantPower Switching & Controls
Precision Cooling
emersonNetworkPower.com/surge
Racks and Integrated CabinetsServices
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2010 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
SL-50200 Rev.1 8/10 Printed in USA
Embedded Power