![Page 1: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/1.jpg)
Shin KUBO, Masaki NISHIURA, Kenji TANAKA, Takashi SHIMOZUMA, Yasuo YOSHIMURA, Hiroe IGAMI,
Hiromi TAKAHASHI, Takashi MUTOHNational Institute for Fusion Science
Collective Thomson Scattering Study using Gyrotron in LHD
Research Center for Development of FIR Region, Univ. of FukuiYoshinori TATEMATSU, Teruo SAITO
Namiko TAMURA,Dept. Energy Science & Technology, Nagoya Univ.
US-Japan Workshop on RF Physics2010.03.8-10 General Atomics, San Diego
![Page 2: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/2.jpg)
Contents
•ECRH System in LHD --> Potential as a diagnostic tool•Collective Thomson Scattering•Receiver•Preliminary results•Scattering Volume and CTS spectrum•Sub-Tera Hz Gyrotron Development•Future Plan•Summary
![Page 3: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/3.jpg)
ECRH System
![Page 4: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/4.jpg)
Design of the Antenna System of ECRH in LHD
• Two sets of upper antennas from 5.5U and 9.5 U port for 82.7GHz and 168GHz
• Two 84 GHz Antenna from 1.5 L port
• All antennas can focus and deposit the power within r<0.2 for Rax=3.53m,B=2.951 T
• Antenna Scan Range– U antenna
• R=-3.2-3.8m, t=±0.2m on mid plane
– L antenna• R=-3.0-4.2m,t= ±1.5m
![Page 5: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/5.jpg)
6
Elliptical Gaussian Beam Focusing Scheme
168GHz Beam
SteeringMirror
FocusingMirror
from Waveguides
84GHz Beam
SteeringMirror
FocusingMirror
mid-plane Focusing MirrorBi-focal Mirror
Waveguide mouth
![Page 6: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/6.jpg)
Hot test of beam steering/focusing• Errors of steering for tor/rad-directions notably affect deposition profile• Beam steering/focusing were checked in vacuum vessel of LHD by using
Kapton film and IR-camera.
![Page 7: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/7.jpg)
ECRH Beam as a Scattering Probe Beam• Well defined beam for heating is also suitable
for probe beam for scattering measurement.– High power density, High Frequency
Modulation• Good S/N Ratio
– Controllable• Scattering Cross Section Position• Scattering Angle
• Promising Candidate for– Density Fluctuation Measurement
• Structure study of micro-turbulence– Wave detection
• EC wave, LH wave, IC wave, Alfven wave– Collective Thomson Scattering
• Ion temperature measurement• Alpha particle distribution study
EC wave, LH wave, IC wave, Alfven wave
![Page 8: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/8.jpg)
9
Collective Scattering using
ECRH System
![Page 9: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/9.jpg)
10
Collective Scattering Condition
3
θ =10 deg θ =90 deg
![Page 10: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/10.jpg)
11
LHD ECH Antenna Configuration (2008)
9.5U Antennaout 82.7 GHzin 77 GHz
5.5U Antennaout 82.7 GHzin 168 GHz
1.5L Antennaout 84 GHzin 84 GHz
2-O Antennaright 77 GHzleft 168 GHz
3.5 inch corrugated WG
3.5 inch corrugated WG
3.5 inchcorrugated WG
1.25 inch corrugatedWG
![Page 11: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/11.jpg)
12
LHD ECH Antenna used for probe and receiving beams
3
9.5U Antennaout 82.7 GHzin 77 GHz
5.5U Antennaout 82.7 GHzin 168 GHz
1.5L Antennaout 84 GHzin 84 GHz
2-O Antennaright 77 GHzleft 168 GHz
3.5 inch corrugated WG
3.5 inch corrugated WG
3.5 inchcorrugated WG
1.25 inch corrugatedWG
waist size 0.015 mwaist size 0.02 m 0.8 MW/5s, 0.24 MW/CW
![Page 12: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/12.jpg)
13
Present ECRH System in LHD
•Two sets of transmission line/ antenna are installed on the ports. •9.5U, 5.5U 1.5L and 2O
![Page 13: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/13.jpg)
14
Proposed Scattering Probe/Receiving transmission Line
•A set of transmission line/ antenna on the 9.5U port is used for CTS.•A line which 77GHz 1MW power available is used for probe beam
![Page 14: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/14.jpg)
15
Receiver Setting Configuration
![Page 15: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/15.jpg)
16
Attached Receiver System
![Page 16: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/16.jpg)
plasma
f0+df
f0+df+fs
gyrotrondf~200MHz
power monitor
ECRH Transmission line(corrugated waveguide)
fixed local oscillatorstability < 10 MHz
pin SW
Notchfilter
Att. BPF
WG SW
Filtek HPF
fl=78 GHz
Mixer
A1
A2A3
Isolator
Two way divider 1
Two way divider 2
high freq.
low freq.
500-200
900-200
1300-200
1700-200
1900-100
2100-100
2300-100
2500-100
Four way divider Diodes
Video Amps.(x1000)
monitor port
measure port
A1: Cernex CBLU1103030-01A2: Cernex CBLU1103050-01A3: Amplitek apt4_SN104331
Heterodyne Receiver for Collective Thomson Scattering in LHD (2008)
![Page 17: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/17.jpg)
Filter CombinationLocal Oscillator 74 GHz
•Filter combination•Center freq.
•IF 3 GHz•sensitive low freq. IF
•for high energy ions•narrow band dense near center freq. IF
•for bulk ion•wide band sparse at peripheral IF
•for high energy ions
![Page 18: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/18.jpg)
Actual Receiver Configuration
IF Amps.
WaveguideSwitch
Splitters
Filters
Mixer
Local Oscillator
PIN Switch
Notch Filter
Horn Antenna
Waveguidefor Probe
Beam
From 77 GHz Gyrotron
![Page 19: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/19.jpg)
During the first trial of CTS measurement,the local oscillator of 74 GHzwas damaged,
Actual Filter Combination
and switched tentatively to78 GHz Courtesy of Dr. T. Tokuzawa
![Page 20: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/20.jpg)
Ch.1,4,5 double side bandCh.2,3,6-8 lower side band
Background, calib.
CTS componentAll channel lower side band Ch2,3 almost notched
10-3
10-2
10-1
100
0 1 2 3 4 5 6 7 8 9
%) /# &)*312!( $,( "'.0-/, '.+, &)*312 !( $,( "
Cal.
Fact
or(V
/eV)
Channel
2009.01.23ΔT=210 deg. lock-in factor=3.0
Effect of Notch Filter
Actual Filter Combination and Calibration with Liq N2
![Page 21: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/21.jpg)
78GHz local combination
Measured Notch FilterCharacteristics Courtesy of Prof. A. Mase
FilterCharacteristics Courtesy of Prof. Y. NagayamaDr. T. YoshinagaMr. D. Kuwabara
![Page 22: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/22.jpg)
Actual Measurement Configuration
B=2.75 TR=3.6 mrho=0.7±0.2k ~ perpendicular
![Page 23: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/23.jpg)
25
Preliminary Results
![Page 24: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/24.jpg)
✴B=2.75T, R=3.6m✴Fundamental ECRH Plasma
Fundamental ECRH plasma ✴B=2.75T, R=3.6m✴Fundamental ECRH Plasma• Noise well suppressed•Spikes at every modulation turn-on, off
•due to spurious mode oscillation from gyrotron•removable by pin switch
Fundamental ECRH plasma (double side band factor)
![Page 25: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/25.jpg)
Expanded in time (#91758)
![Page 26: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/26.jpg)
Expanded in time (#91758)
![Page 27: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/27.jpg)
CTS #91758 (double side band factor)
✴B=2.75T, R=3.6m✴Fundamental ECRH Plasma• Noise well suppressed•Spikes at every modulation turn-on, off
•due to spurious mode oscillation from gyrotron•removable by pin switch
![Page 28: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/28.jpg)
CTS #91758 (double side band factor)
✴B=2.75T, R=3.6m✴Fundamental ECRH Plasma• Noise well suppressed•Spikes at every modulation turn-on, off
•due to spurious mode oscillation from gyrotron•removable by pin switch
![Page 29: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/29.jpg)
Analysis ECRH plasma
Decompositionof scattering
component from heating/heat
wave componentis necessary
![Page 30: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/30.jpg)
Method of analysis• Raw data of several modulation periods are
rearranged in time relative to the turn on/off time
• These rearranged data are fitted with the function
• δa corresponds to background increments/decrements due to heating (change in slope)
• δb corresponds to increment/decrement due to scattered signal over background (stepwise change)
![Page 31: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/31.jpg)
Example of deduced raw signal change
![Page 32: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/32.jpg)
Spectrum change in time
![Page 33: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/33.jpg)
Example of deduced scattered power spectrum
![Page 34: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/34.jpg)
36
Receiver Improvements
![Page 35: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/35.jpg)
Heterodyne Receiver for Collective Thomson Scattering in LHD (2009)
fixed local oscillatorstability < 10 MHz
pin SW
Notchfilter
Att.
BPF
WG SW
fl=74 GHz
MixerIsolator
HPF
A1 A2
A3
A4A4
A4A4
A4A4
A4A4
A3
n
ECRH Transmission line(corrugated waveguide)
5th-HarmonicMixer
n
fl1-ndf
A5
HPF
Att A5
HPF *
HarmonicMixer
Error AmpVoltage Controlled
Oscillator
plasma
f0+df
f0+df+fs
gyrotrondf~200MHz
power monitor
ADC
ADC
ADC
ADC
32 channel VideoAmp.(x100)
LPF
Filters
Low NFAmps
PowerAmps
2<f<8GHz
f<6GHz
f>0.3GHz
0.5<f<4GHz
0.5<f<18GHz
![Page 36: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/36.jpg)
Increased IF bands local frequency = 74.00 GHz
![Page 37: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/37.jpg)
IF filter characteristics
![Page 38: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/38.jpg)
40
Scattering Volume• Key to confirm scattering signal
confirmation• Necessary for absolute calibration
![Page 39: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/39.jpg)
Beam Cross Section Controlled by beam steering
receiving beamprobing beamprobing beam receiving beam
ρ=1.0
ρ=0.19.5U in 77GHz injection9.5U out receiving
Max cross section at ρ=0.75 Zero cross section
![Page 40: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/40.jpg)
• Scattering power
is obtained using scattering form factor
Γ: geometrical factorre: classical electron radiusne: electron densitydω: band widthrR: beam radiusλs0: wavelength of scattered
radiationS(k,ω): scattering form factor
Probebeam
Scatteredbeam
fromGyrotron
toReceiver
SN ratio of CTS
![Page 41: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/41.jpg)
43
Scattered Power
![Page 42: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/42.jpg)
U-antenna for 168 GHz used for 77 GHz Scattering
•Beam evolution is recalculated with the 168 GHz antenna mirror configuration radiated from the same waveguide mouth for 77 GHz beam •Resultant beam sizes on the mid-plane are •20 mm in radial •99 mm in toroidal
If the configuration of the mirrors and optical axis are the same,i. e. cosφ and ρ are kept ,relation between Rin and Rout are defined by
even for different frequency, or beam size
77 GHz168 GHz
bi-focal mirrorfinal focus mirror
7777
![Page 43: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/43.jpg)
45
Scattering using Gaussian Beam
![Page 44: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/44.jpg)
46
Cross Volume of Gaussian Beam
![Page 45: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/45.jpg)
47
Surface of Cross Volume
![Page 46: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/46.jpg)
48
Cross Volume and resolution
![Page 47: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/47.jpg)
49
Scattering using Gaussian Beam
Scattering Length
![Page 48: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/48.jpg)
50
Scattered intensity and effective scattering length well scale
center
top
bottom
Scattered spectrum are fitted with offset-Gaussian to subtract ECE background
Intensity ratio of the scattered power well scales to the calculated effective scattering length
![Page 49: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/49.jpg)
Comparison of Exp. / Cal. Spectrum
51
Measured data are used for calculation.• Te=0.6keV• TAr=0.7keV• ne=2.5x1019m-3
• nfast=0.1x1019m-3
• Ti=0.7keV is better fitting than Ti=2keV.
• Measured data seems to have an offset of +0.1GHz.
• P(3.6,0,0), R(3.6,0,0)• Vsc=153.3cm3
1
10
100
1000
-3 -2 -1 0 1 2 3
Calculated CTS spectrumscattered radiation
Scat
tere
d Po
wer
(eV)
frequency (GHz)
![Page 50: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/50.jpg)
52
Sub-Tera Hz Gyrotron
Development
![Page 51: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/51.jpg)
FIR FUCTS in LHD
fi > 4fce suppression of ECE400 GHz band is one choice. Salpeter Parameter
Linked with slide 15
R along scattered wave path (m)
![Page 52: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/52.jpg)
FIR FU
Achieved 50 kW
• More than 50 kW at 349 GHz and about 40 kW at 390 GHz have been achieved. These are highest powers as second harmonic oscillation of gyrotron.
• Oscillation efficiency decreases for large beam current possibly due to degradation of the quality of the electron beam.
From Notake PRL paper
Vk = 57 kV
![Page 53: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/53.jpg)
Future Plan• Establish Calibration/Analysis procedure
• Scattering Volume
• CTS spectrum and reduction of ion/fast ion temperature
• Calibration including polarizer/waveguide coupling
• Multi receiver / fast volume scan• Precise background subtraction
• Simultaneous measurement in 2-D velocity space
• Expansion in real/velocity space
• Sub-Tera Hz Gyrotron Application to CTS
![Page 54: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/54.jpg)
57
LHD ECH Antenna used for probe and receiving beams
3
9.5U Antennaout 82.7 GHzin 77 GHz
5.5U Antennaout 77 GHzin 168 GHz
1.5L Antennaout 84 GHzin 84 GHz
2-O Antennaright 77 GHzleft 168 GHz
3.5 inch corrugated WG
3.5 inch corrugated WG
3.5 inchcorrugated WG
1.25 inch corrugatedWG
waist size 0.03 m 0.8 MW/5s, 0.24 MW/CW
![Page 55: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/55.jpg)
ECRH Horizontal Antennafor parallel component
• 2 sets of• Focusing Mirror
• Symmetric Gaussian Beam
• 35 mm waist size at plasma center
• Steering Plane Mirror• Toroidally +/- 30
degree• Poloidally +/- 10
degree
![Page 56: Collective Thomson Scattering Study using … f0+df f0+df+fs gyrotron df~200MHz power monitor ECRH Transmission line (corrugated waveguide) fixed local oscillator stability < 10 MHz](https://reader031.vdocuments.us/reader031/viewer/2022022018/5b904a1a09d3f28a7e8b9c12/html5/thumbnails/56.jpg)
Summary•Started CTS utilizing ECRH system in LHD77GHz ( P~1MW) Gaussian beam is used as a probe.Injection ECRH antenna is used as a receiver. Backward, perpendicular 8/32 channel receiver system is attached to ECRH transmission line 3 s, 50 Hz modulated injection at 0.7 MWPreliminary results with 8/32 channel show promising CTS signals
•32 channel•Higher reliability in ion velocity distribution reduction
•Examining possible use of horizontal antennas•Backward, parallel components
•Sub-THz gyrotron developed for CTS in LHD