By the end of this training, in order to get your operatorcard, the instructor must attest to your workingknowledge of the instrument.
This is accomplished either through personalknowledge of your skills and abilities, or by personallydemonstrating your knowledge through use of the
instrument. This can be accomplished by using the instrument in a
demonstration format for the instructor.
-
8/13/2019 Breath Testing Operator Class Instrumentation
3/115
They are INSTRUMENTS that is used formeasuring the concentration of ethanol inhuman breath.
Instruments measure, machines do work.Machines break down, instruments needrecalibration.
Machines are used by mechanics, instrumentsare used by scientists.
-
8/13/2019 Breath Testing Operator Class Instrumentation
4/115
Alco-Sensor III series begins on slide 5
Lifeloc FC20 begins on slide 29
Intoxilyzer 5000 series begins on slide 90
Certification for the ASIII and Intoxilyzer 5000 covers theentire series of those instruments that are approved for use inthe state of Idaho.
-
8/13/2019 Breath Testing Operator Class Instrumentation
5/115
How does it work?
The ASIII is a fuel cell instrument
A 1 mL sample is taken from the expired breath and analyzed by a chemical reaction with the alcohol on their breath.
Represents a single point in time snapshot of the alcoholcontent in the breath that was sampled.
-
8/13/2019 Breath Testing Operator Class Instrumentation
6/115
The fuel cell:
-
8/13/2019 Breath Testing Operator Class Instrumentation
7/115
H3PO4Pt
ALCOHOL ACETIC ACID + e- CO 2 + O 2 + H 2O
RAPID SLOW
Alcohol reacts to produce electrons (electricity). This electriccurrent represents the amount of alcohol in the breath sample.
electrons
-
8/13/2019 Breath Testing Operator Class Instrumentation
8/115
How does it work?
The electrons are given off in an exact proportional
ratio with respect to the EtOH.Therefore the electric current produced by this reactionis directly proportional to the amount of EtOH present.This result is displayed on a digital readout as BrAC.
-
8/13/2019 Breath Testing Operator Class Instrumentation
9/115
Specific?
The fuel cell is not specific to ethanol and will react
with all alcohols. Technically 18-8004 states It is unlawful for any person who
is under the influence of alcohol, drugs or any otherintoxicating substances, or who has an alcohol concentrationof 0.08 . to drive or be in actual physical control of a motorvehicle
-
8/13/2019 Breath Testing Operator Class Instrumentation
10/115
Operation:
The SET button controls the
spring-loaded sampling valve.With the SET button in thelocked-down position, theAlco-Sensor is ready to take asample.
-
8/13/2019 Breath Testing Operator Class Instrumentation
11/115
The SET button clears the sample chamber when it isdepressed. This purges the chamber of all air andreadies it to accept a sample.
When the instrument is not actually reading a sample,the SET button should be locked down. This helps to
prevent the fuel cell from drying out.
-
8/13/2019 Breath Testing Operator Class Instrumentation
12/115
The READ button .
Light pressure on the READ button unlocks the SET
button and draws a 1ml sample of air into the fuel cellfor testing.
Continued full pressure on the READ button connectsthe 9-volt battery with the digital display and thealcohol reading appears. (Older version)
-
8/13/2019 Breath Testing Operator Class Instrumentation
13/115
On the older versions, if you let go of the READ button, the display goes blank.
You must keep the pressure on the READ button untilthe display stops climbing and stabilizes.
The new version of the AS III; no need to hold READ button down.
The new version has the red slider on the side for releasing themouthpieces. It also does not have the liquid crystalthermometer.
-
8/13/2019 Breath Testing Operator Class Instrumentation
14/115
ASIIIa (the new version)
Once the READ button is pressed, (no need to hold it
down) the reading will appear dim. When it suddenly brightens, the analysis is finished and the peak readingis displayed.
-
8/13/2019 Breath Testing Operator Class Instrumentation
15/115
If the DIGITAL DISPLAY shows .888 , this means that the 9volt battery is low and should be replaced.
The new version may give you a bAT message toindicate that the battery need replacing.
Use only a 9-volt alkaline battery.
-
8/13/2019 Breath Testing Operator Class Instrumentation
16/115
AIR INLET PORT
This port has a flared top to hold the mouthpiece
securely.
Air is drawn through the inlet port and into the fuelcell for analysis.
-
8/13/2019 Breath Testing Operator Class Instrumentation
17/115
Mouthpieces?
The 2002 Operators Manual states:
Using mouthpieces of other design than those supplied by the manufacturer may cause inaccurate readings byas much as 10-20%. For instance, whistling or overlyrestrictive mouthpieces can either draw room air into
the breath sample or pressurize the systeminaccuratereadings
-
8/13/2019 Breath Testing Operator Class Instrumentation
18/115
Intoximeters on the right, brand X on the left. Which is more restrictive??
-
8/13/2019 Breath Testing Operator Class Instrumentation
19/115
LIQUID CRYSTAL THERMOMETER
Located on the back of the Alco-Sensor III.
Has a range of 20C to 38 C (the optimum operatingtemperature of the instrument ).
When reading the thermometer, use the last numberthat you can read clearly as the temperature.
-
8/13/2019 Breath Testing Operator Class Instrumentation
20/115
The New Version ASIIIa
Hold the SET and READ buttons down.
Temperature is displayed in degrees C.
Acceptable range for use is 15 C to 36 C.
What does 15 C to 36 C equal in F ?? It would be a range between 59 F and 96F.
-
8/13/2019 Breath Testing Operator Class Instrumentation
21/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
22/115
RFI?
RADIO FREQUENCY INTERFERENCE
Can cause unusual readings on the display.Officers should watch the display for fluctuations ofthe reading.
-
8/13/2019 Breath Testing Operator Class Instrumentation
23/115
General Maintenance:
Avoid exposure to cigarette smokeAvoid temperature extremesLock Set button between uses Cycle Set/Read if flooded, may require theinstrument to sit overnight.Use the instrument regularly. The moisture from your
breath will help keep the fuel cell moist andfunctioning properly for a long time.
-
8/13/2019 Breath Testing Operator Class Instrumentation
24/115
Testing sequence again 1. 15 minute monitoring period2. Check temperature of ASIII.3. BLANK (must be 0.003 or less)4. SAMPLE 1 new mouthpiece, get a deep lung air
sample.5. WAIT approximately 2 minutes6. BLANK (must be 0.003 or less)7. SAMPLE 2 new or same mouthpiece
~if the first two samples are more than 0.020 apart then:8. WAIT approximately 2 minutes9. BLANK (must be 0.003 or less)10. SAMPLE 3 new or same mouthpiece
-
8/13/2019 Breath Testing Operator Class Instrumentation
25/115
With a Printer:
You will get a printout after the last BLANK when you lock inthe SET button.
When the test is completed, enter the results on the log sheet.
If you have a printout, use the first time shown by the first BLANK. Logging the results is the last step in the Alco-Sensor test. Enter the information LEGIBLY, so it can be read at a later date.
Someone may have to testify to your handwritten results.
-
8/13/2019 Breath Testing Operator Class Instrumentation
26/115
New ASIIIa
After the final test result is displayed, the instrument will flashSET 10 times, then go into power save. At any time after the final test result is displayed and Beforethe SET button is pressed , pressing the READ button will
bring up the most recent test on the display.Once the SET button is pressed, the test cannot be recalled.
-
8/13/2019 Breath Testing Operator Class Instrumentation
27/115
New ASIIIa
Some messages that may appear on the display:
SEt Lock down the SET button. bAt Battery needs replacement.
bLn Press READ button to run an air blank. bAd Instrument unable to run a successful blank.
-
8/13/2019 Breath Testing Operator Class Instrumentation
28/115
Up next:
Lifeloc FC20
-
8/13/2019 Breath Testing Operator Class Instrumentation
29/115
Officially approved for evidentiary use in Idaho as ofFebruary 1, 2008.
It is a fuels cell instrument like the ASIII.
-
8/13/2019 Breath Testing Operator Class Instrumentation
30/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
31/115
H2SO4Pt
ALCOHOL ACETIC ACID + e- CO 2 + O 2 + H 2O
RAPID SLOW
Alcohol reacts to produce electrons (electricity). This electriccurrent represents the amount of alcohol in the breath sample.
electrons
-
8/13/2019 Breath Testing Operator Class Instrumentation
32/115
How does it work?
The electrons are given off in an exact proportionalratio with respect to the EtOH.Therefore the electric current produced by this reactionis directly proportional to the amount of EtOH present.This result is displayed on a digital readout as BrAC.
-
8/13/2019 Breath Testing Operator Class Instrumentation
33/115
Specific?
The fuel cell is not specific to ethanol and will reactwith all alcohols.
Technically 18-8004 states It is unlawful for any person whois under the influence of alcohol, drugs or any otherintoxicating substances, or who has an alcohol concentrationof 0.08 . to drive or be in actual physical control of a motorvehicle
-
8/13/2019 Breath Testing Operator Class Instrumentation
34/115
Rapid response~250 Test memoryPrint results later*
Auto-test modeManual override0.02 agreement requiredInsufficient sampledetermination
-
8/13/2019 Breath Testing Operator Class Instrumentation
35/115
Printer capable :
Print now or later
Rechargeable batteriesThermal printerImpact printer
Impact: Ribbon or noribbon (three-copy paper)
-
8/13/2019 Breath Testing Operator Class Instrumentation
36/115
FC20 serial numberEvent number
Test date
Manual test indicator
Subject ID data
-
8/13/2019 Breath Testing Operator Class Instrumentation
37/115
Testing sequence again 1. 15 minute monitoring period2. MANUAL BLANK (must be 0.000 or less)3. SAMPLE 1 new mouthpiece, get a deep lung air
sample.4. WAIT automatic countdown for 2 minutes5. AUTO BLANK (must be 0.000 or less)6. SAMPLE 2 new or same mouthpiece
~if the first two samples are more than 0.020 apart then:7. WAIT automatic countdown for 2 minutes8. AUTO BLANK (must be 0.000 or less)9. SAMPLE 3 new or same mouthpiece
-
8/13/2019 Breath Testing Operator Class Instrumentation
38/115
Mouthpiece has two ports that must alignwith ports on the
instrument
-
8/13/2019 Breath Testing Operator Class Instrumentation
39/115
The mouthpiece mustfit tightlyPractice: Installwithout taking eyes offsubject
-
8/13/2019 Breath Testing Operator Class Instrumentation
40/115
Five Main Menu Screens press Function 1) Testing: Appears at power-on
2) Printing: Appears at conclusion of subject testing3) Calibration: Used for Performance Verifications4) Settings: Date, time, printing, others5) Status: Test log status, battery, temperature
-
8/13/2019 Breath Testing Operator Class Instrumentation
41/115
Any time youre in the
various menus, pressingthe Power button brieflywill take you back to theSubject I.D. window
-
8/13/2019 Breath Testing Operator Class Instrumentation
42/115
Sequence Mode OnManual overrideavailable by pressing theexec button during the
blow.Subject I.D. is firstdisplay; +/- keys to enter;Function = by-pass.I.D. data appears on
print-out
-
8/13/2019 Breath Testing Operator Class Instrumentation
43/115
If the instrument is toohot or too cold, thismessage appears and
instrument will notoperate until the internaltemperature is withinrange.
The instrument is testeddown to 10C and up to37C
-
8/13/2019 Breath Testing Operator Class Instrumentation
44/115
Warns that theinstrument calibration isgoing to expire.
Starts 14 days prior toexpiration. No numerical countdownReturn to ISP lab
-
8/13/2019 Breath Testing Operator Class Instrumentation
45/115
WHY?
14 day warning.180 210 days (~ 6-7 months)Quality control.Fuel cell break-in period.If a single jurisdiction gets multiple FC20s, ISP-FS willstagger the expiration so not all the instrument aredown at once.Will only happen one time, then the countdown will bedisabled.
-
8/13/2019 Breath Testing Operator Class Instrumentation
46/115
The calibration hasexpired.Instrument will not run
any subject tests or WetChecks/PerformanceVerifications.Must be calibrated byISP.
-
8/13/2019 Breath Testing Operator Class Instrumentation
47/115
Air blank must be 0.000 or it fails, so be extra carefulwhere your test subject is breathing when you run a
blank.If it fails, then it will count down two minutesSecond air blank will be taken automatically.If you get a second failure: Aborted: 2 air blank failures
will be displayed and the instrument will discontinuethe testing sequence.
-
8/13/2019 Breath Testing Operator Class Instrumentation
48/115
Power onUse +/- keys to enterletters, numbers
Press functionAir blank screenSubject ID may be
bypassed withFunction
-
8/13/2019 Breath Testing Operator Class Instrumentation
49/115
Event 118Battery iconPress Exec to take air
blankFirst air blank notautomatic
-
8/13/2019 Breath Testing Operator Class Instrumentation
50/115
During auto sequencethe succeeding air
blanks are automaticTwo minute countdownAir blank runs
Countdown clock
-
8/13/2019 Breath Testing Operator Class Instrumentation
51/115
If the test result was anything other than 0.000 the blank fails, it is important to remove the mouthpiecefor the air blanks.
Not uncommon for instruments with complexmouthpieces to retain moisture in the cornersSometimes necessary for Alco-Sensor IIIEspecially if it is cold outside and their breath
condenses inside the mouthpiece.You can use a new mouthpiece if necessary.
-
8/13/2019 Breath Testing Operator Class Instrumentation
52/115
Ready for subjectDefaults back to amanual air blank if test
not taken within twominutesAir blank time out Must press Exec totake the next air blank
-
8/13/2019 Breath Testing Operator Class Instrumentation
53/115
Sequence mode offCan use the auto testfeature in manual modefor instrumental deeplung air calculationMust press Exec totake the air blanks
All samples and timingof blanks are dependentupon the operatorKeep good records ofthe results!!Log everything
-
8/13/2019 Breath Testing Operator Class Instrumentation
54/115
1st Graph shows subjectis blowing
Not an indication of
alcohol!!Could have a significantgraph with a zero breathalcohol
-
8/13/2019 Breath Testing Operator Class Instrumentation
55/115
If necessary, pressExec to take sample
Auto-Test
Manual test taken
-
8/13/2019 Breath Testing Operator Class Instrumentation
56/115
A visual aidInstrument isdetermining alcohol
concentration in sample
-
8/13/2019 Breath Testing Operator Class Instrumentation
57/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
58/115
Subject refuses testBriefly press PowerThis screen appears
Press Exec to change
-
8/13/2019 Breath Testing Operator Class Instrumentation
59/115
When this screenappears, press Function
-
8/13/2019 Breath Testing Operator Class Instrumentation
60/115
Use Exec to select eitherSubject Refusal orOperator Termination
Then Function takes youto print screen
-
8/13/2019 Breath Testing Operator Class Instrumentation
61/115
Provides a printed recordBatch number
-
8/13/2019 Breath Testing Operator Class Instrumentation
62/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
63/115
Once in print screen, use+/- to select a certain testfor printing
Or select All
-
8/13/2019 Breath Testing Operator Class Instrumentation
64/115
Function/FunctionPrint IconUse +/- buttons to select
All Exec should print Prints all test results
-
8/13/2019 Breath Testing Operator Class Instrumentation
65/115
Prints StoredCalibration/PerformanceVerification Data
-
8/13/2019 Breath Testing Operator Class Instrumentation
66/115
Notches and screws on plug face up.
-
8/13/2019 Breath Testing Operator Class Instrumentation
67/115
Not connected Not turned onCable problem
Fix and print
-
8/13/2019 Breath Testing Operator Class Instrumentation
68/115
PumpMotor
PumpBellows
Fuel Cellunder this bracket
-
8/13/2019 Breath Testing Operator Class Instrumentation
69/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
70/115
Should be seen rarelyIf it appears more thanonce, contact Lifeloc
-
8/13/2019 Breath Testing Operator Class Instrumentation
71/115
Use Function toget to CalibrationscreenThen Exec takesyou to Wet Checkscreen
-
8/13/2019 Breath Testing Operator Class Instrumentation
72/115
Can use the +/- buttonsto adjust the Std valueThe Std value printsalong with the resultsConnect to simulatorPress Exec to take
sample
-
8/13/2019 Breath Testing Operator Class Instrumentation
73/115
Results are displayedPress Exec to print
No air blanks required
Wet Check screen comesup againTake sample, print
-
8/13/2019 Breath Testing Operator Class Instrumentation
74/115
Must print immediatelySucceeding Wet Check results will overwrite, the datawill be lostOnce the simulator is ready and the connection made,two samples can be run and printed in two minutes orless.
-
8/13/2019 Breath Testing Operator Class Instrumentation
75/115
Date instrument was lastcalibrated
Date of your performanceverification
One printout per samplerun
-
8/13/2019 Breath Testing Operator Class Instrumentation
76/115
Wet Check ResultsPrint-as-you-goMemory only stores
most recent resultRun-print-run-print
Will be overwritten ifanother Wet Check is run
-
8/13/2019 Breath Testing Operator Class Instrumentation
77/115
Run the cal check as a Subject SampleInput subject I.D. as Cal check 08/20
Once the simulator is connected and ready, two samples can be run and printed.May have to use the manual test when using a simulator.ADVANTAGE results will be stored until deleted fromthe test log.
DISADVANTAGE results will not be included on thelong format when printing and could be confusing if thelong format is being utilized.
-
8/13/2019 Breath Testing Operator Class Instrumentation
78/115
Shorter is better!!Less condensationTubing and mouthpieceshould fit tightly, notlike shown here!
Fitting available fromISP labs
-
8/13/2019 Breath Testing Operator Class Instrumentation
79/115
Mouthpiece and cleartubingAlco-Sensor IIImouthpiece insertinstead of tubingSimilar for other
simulators
-
8/13/2019 Breath Testing Operator Class Instrumentation
80/115
Accessed with Function Battery conditionInstrument temperatureSoftware version
-
8/13/2019 Breath Testing Operator Class Instrumentation
81/115
Warning Low Batterydisplayed in testingwindow when the
batteries are criticalDo not use rechargeable
batteries
-
8/13/2019 Breath Testing Operator Class Instrumentation
82/115
Does not automatically adjust for DSTPress Function until the Settings screen appears. Use+/- to adjust hours, press Next Digit to move tominutesPress Function to bring up datePress Function to bring up Shutoff TimePress Function again, ID Settings screen
-
8/13/2019 Breath Testing Operator Class Instrumentation
83/115
Recommend Subject ID Letters/Numbers may be entered, printBatch may be used to ID an agency, operator. Doesnot need to be re-entered every test. Also printsMay use both Subject ID and Batch
-
8/13/2019 Breath Testing Operator Class Instrumentation
84/115
Normal testing for IdahoFunction takes you toPrint Settings
Or press Power button briefly to go back toSubject IDTurning this option off
puts the instrument inmanual mode
-
8/13/2019 Breath Testing Operator Class Instrumentation
85/115
Number of copiesPrinter selectionFormat: Long or Short
Long format includesdate of last calibrationand most recent
performance verification
This is a Wet Check printout. Long formatincludes this data along
with subject test
-
8/13/2019 Breath Testing Operator Class Instrumentation
86/115
Function from Print Settings Adjust contrast with the +/- buttonsTest order: Auto-Man-PassiveResults format: NumericPass and Fail levels-not relevant
-
8/13/2019 Breath Testing Operator Class Instrumentation
87/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
88/115
Status displayPressing Exec in the ClearTest Log-No screen takes youto this display
Function will now erasethe test logPressing Function will
now clear the log
No way to recover data! Ever!! Never Ever!!!
-
8/13/2019 Breath Testing Operator Class Instrumentation
89/115
Questions?
-
8/13/2019 Breath Testing Operator Class Instrumentation
90/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
91/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
92/115
The Intoxilyzer 5000 uses the principle of infraredabsorption.Each molecule of alcohol absorbs a certain frequencyof infrared light.The amount of light absorbed is directly proportionalto the amount of alcohol present.A known intensity of light is transmitted through a
sample chamber.
-
8/13/2019 Breath Testing Operator Class Instrumentation
93/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
94/115
A detector is located on the far side of the samplechamber.The difference between the amount of lighttransmitted and the amount of light detectedcorrelates directly with the amount of light absorbed
by the alcohol.The instruments computer calculates the exact
concentration of alcohol in the sample chamber basedupon this difference.
-
8/13/2019 Breath Testing Operator Class Instrumentation
95/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
96/115
*23 on display means your source is out.(Change light bulb)
-
8/13/2019 Breath Testing Operator Class Instrumentation
97/115
No switchesFive filtersStandby ModeAutomatic Simulator Temperature monitoringSwitches Automatically to External Printer
-
8/13/2019 Breath Testing Operator Class Instrumentation
98/115
A. Breath tube is a heated tube (>34C)which directsthe subjects breath into the chamber.(Also containsa wire that is the antennae for the RFI detectsystem)
B. The mouthpiece is a disposable plastic piece with a baffle to keep stuff out of the instrument C. The digital display is a 16 character alpha-numeric
readout which contains a variety of information for
the operator.
-
8/13/2019 Breath Testing Operator Class Instrumentation
99/115
D. The green START BUTTON starts the test.E. The red POWER SWITCH turns the instrument on
and off.F. The evidence card is a three copy printout showing
instrument location, date, instrument serial number,subject name, subjects drivers license number,operator name, agency, lot number, calibration
check results, subject test results along with timesfor each.
-
8/13/2019 Breath Testing Operator Class Instrumentation
100/115
G. Computer RESET SWITCH is a rocker switch that
is used in certain circumstances to cancel alloperations and return the instrument to the notready mode (it should then cycle into the standbymode). Similar to a computer reboot.
-
8/13/2019 Breath Testing Operator Class Instrumentation
101/115
Monitors and compares the ratio of light absorption atdifferent wavelengths.Uses a reference wavelength that does not react withany substance in the human breath.
5 Filters: (0) Reference channel, (1)alcohol channel,(2,3,4) interferent comparison channels.All the filters work together to make the instrumentmore specific for Ethyl Alcohol concentration.
-
8/13/2019 Breath Testing Operator Class Instrumentation
102/115
The instrument will cancel the test and print INVALIDSAMPLE. How does it know?When you breathe, what breath comes out first?
-
8/13/2019 Breath Testing Operator Class Instrumentation
103/115
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
Duration of breath sample
E t O H C o n c e n t r a
t i o n
Mouth alcohol present
Example of BAC = 0.16(no mouth EtOH present)
-
8/13/2019 Breath Testing Operator Class Instrumentation
104/115
Answer questions entering subject dataThe instrument will automatically perform a purgeand blank, then will check the internal standards andcalibration
If the internal standards pass, another air blank will be taken and the testing sequence will continue. If the internal standards fail, INTERNAL
FAILED will be displayed, another air blank will
be taken and the testing sequence will end.
-
8/13/2019 Breath Testing Operator Class Instrumentation
105/115
If the instrument standards are within range, theinstrument will perform a calibration check usingan external (simulator) standard. If the performanceverification check is within range, another air blankwill be taken and the testing sequence will continue.
If the PV check fails, OUT OF TOLERENCE
will be displayed, another air blank will be takenand the testing sequence will end.
-
8/13/2019 Breath Testing Operator Class Instrumentation
106/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
107/115
If the first two samples are 0.02 or more apart, theinstrument will automatically request a third sample.
If the subject refuses to provide any of the samples, press the green START button when PLEASEBLOW/R shows on the display. Or you could let the instrument time out (3 min).
-
8/13/2019 Breath Testing Operator Class Instrumentation
108/115
Printouts are a permanent record of the test results and blanks for your subject testThe log sheet is just as important as the printout andmay be used in court in lieu of the printout.
-
8/13/2019 Breath Testing Operator Class Instrumentation
109/115
-
8/13/2019 Breath Testing Operator Class Instrumentation
110/115
Older instruments (66-series) Blow hard enough to open the pressure switch Blow for a minimum of 5 seconds The instrument must detect a positive slope that is leveling off.
If these requirements are not met the instrument will flag deficient sample
-
8/13/2019 Breath Testing Operator Class Instrumentation
111/115
5000 EN 1.1 Liters of air must be expired Blow for a minimum of 1 second The instrument must detect positive slope that is leveling off.
If these requirements are not met the instrument will flag deficient sample
-
8/13/2019 Breath Testing Operator Class Instrumentation
112/115
Clean case with non-abrasive spray.
Keep the area around the instrument free of dirt anddust.
Do not place anything on top of the instrument.
-
8/13/2019 Breath Testing Operator Class Instrumentation
113/115
A performance verification is performed before everysubject test It must pass or the test is aborted
The instrument does not need to be calibrated unless it
cannot pass its performance verification checks.
-
8/13/2019 Breath Testing Operator Class Instrumentation
114/115
An external simulator solution is used to confirm the performance of the Intoxilyzer 5000.The operator must verify that all connections are tightand that the simulator temperature is within range. The temperature must be between 33.5 C and 34.5 C. If not, do not run
the test. If the simulator is turned off, turn it on and wait at least 15 minutes for
the solution to warm up before running test. The simulator is ready when the top metal lid is as warm as the bottom
jar.
-
8/13/2019 Breath Testing Operator Class Instrumentation
115/115
Questions