7/28/2019 Annexure i for Specifications of Stands and Tanks
1/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Load / Unload StandMOC : MS structural, two coats epoxy painted 02 nos
Inside dimensions, mm : 1400 x 800 x 1000 H
Construction : 3 mm thick MS sheet with external reinforcement of MS
Leg : MS Channel 100 x 50, epoxy base painted, along 1400mm
Operating media : Hot alkali solution
Operating temperature : 80 deg C
Insulation: 40mm thick glass wool on sand blasted outside surface
backed by 3 mm thick flexible FRP sheet cladding
Heaters : 7.5 kw/230 V/SS-304 :4 nos
Lip exhaust: PPGL /FRP construction on two longitudinal sides
Sensor : One no. at a corner of the tank encased in a SS 316 tube
Digital Temp controller: Shall be installed in the control panel, to control the operation
of the heaters in the tank
V blocks : 2 nos. PP for each tankDrain outlet : 1 in. PP ball valve
Inside dimensions, mm : 1400 x 700/800 x 1000 H
Construction : 15 mm imported Rochiling brand PP sheet external MStubular reinforcement having PP covering & additional PP ribs.
2.Cold swill Tank 09 Nos.
1.Alkaline Degreasing Tank 02 nos
Note: If there are any deviations from the tendered specifications please mention in remarks column.
1
-
7/28/2019 Annexure i for Specifications of Stands and Tanks
2/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Leg : MS channel 100 x 50, epoxy base painted, along 1400 mm.
Operating media : Rinse water
Level controller : Magnetic float switch type p of PP
V blocks : 2 nos. PP of each tank
Water inlet : 3/4 in. PVC ball valve
Drain outlet : 1 in. PVC ball valve.
Inside dimensions, mm : 1400 x 700 x 1000 H
Construction
: 15 mm imported Rochiling brand PP sheet, external MS
tubular reinforcement having PP covering & additional PP
ribs.
Leg : MS channel 100 x 50, epoxy base painted, along 1400 mm
Level controller : Magnetic float switch type, of PP
Operating media : Acid base (nitric acid/NaOH)
Operating temperature: Room
Lip exhaust : PPGL /FRP construction on two longitudinal sides
V blocks : 2 nos. PP of each tank
Water inlet : 3/4 in. PVC ball valve
Drain outlet : 1 in. PVC ball valve
3.Brightening/pickling Tank 02 No.
Note: If there are any deviations from the tendered specifications please mention in remarks column.
2
-
7/28/2019 Annexure i for Specifications of Stands and Tanks
3/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Inside dimensions, mm : 1400 x 800 x 1000 H
Construction : 20 mm imported Rochiling brand PP sheet, external MS
tubular reinforcement having PP covering & additional PP rib.
Leg : MS Channel 150 x 100 epoxy base painted
Operating media : Sulphuric acid
Operating temperature : (-) 8 to (-) 10 deg C
Cooling coil : Titanium Gr-2,16 mm OD 1.6 mm thk for heat transfer
Insulation : 75 mm thick Thermocole / PUF backed by 3 mm thick
flexible FRP sheet cladding
Lip exhaust : PPGL /FRP construction on two longitudinal sides & one
width side at the rear
sensor: One no. at a corner of the tank encased in a Ti tube the heaters
in the tank
Contact saddles : Copper with provision to connect to Rectifier
Bus bar : 30 x 10 x 1800 mm electrolytic copper : 2 nos each to beconnected to rectifier supply
Cathode : Lead electrode with copper fastener
Flight bars : as per the requirement (Copper:100% conductivity)
V blocks : 2 nos. of each tank copper with 100% conductivity
4. Anodisation Process Tank 02 Nos.
Note: If there are any deviations from the tendered specifications please mention in remarks column.
3
-
7/28/2019 Annexure i for Specifications of Stands and Tanks
4/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Inside dimensions, mm : 1400 x 700 x 1000 H
Construction : 3 mm thick SS 304 sheet with external reinforcement of MS
Leg : MS Channel 100 x 50, epoxy base painted, along 1400mm
Operating media : Hot water
Operating temperature : 70 80 deg C
Insulation: 40mm thick glass wool on sand blasted outside surface backed
by 3 mm thick flexible FRP sheet cladding
Heaters : 7.5 kw/230 V/SS-304 : 4 nos
Sensor : One no. at a corner of the tank encased in a SS 316 tube
Digital Temp controller : Shall be installed in the control panel, to control the operationof the heaters in the tank
V blocks : 2 nos. PP
Drain outlet : 1 in. PP ball valve
Control panel : Houses safety gears for the heaters
Inside dimensions, mm : 1400 x 700 x 1000 H
Construction : 3 mm thick SS 304 sheet with external reinforcement of MS
Leg : MS Channel 100 x 50, epoxy base painted, along 1400mm
Operating media : potassium dichromate.
Operating temperature : 70 80 deg C
5.Hot Rinse Tank 02 no.
6.Passivation tank 02 No.
Note: If there are any deviations from the tendered specifications please mention in remarks column.
4
-
7/28/2019 Annexure i for Specifications of Stands and Tanks
5/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Insulation : 40mm thick glass wool on sand blasted outside surface backed
by 3 mm thick flexible FRP sheet cladding
Heaters : 7.5 kw/230 V/titanium : 4 nos
Sensor : One no. at a corner of the tank encased in a SS 316 tube the
heaters in the tank
V blocks: 2 nos. PP of each tank
Drain outlet : 1 in. PP ball valve
Control panel : Houses safety gears for the heaters
Inside dimensions, mm : 1400 x 800 x 1000 H
Maximum temperature : 90 deg C
Construction (inside to out side)
:3MM thick SS 316 sheet suitably reinforcement of MS and
complete with 40 mm thick glass wool insulation encased in 14
SWG GI sheet which is further covered externally covered with
5 mm FRP coating
Seating: 2 MS channel 100X50 mm with FRP coated, along withlength (1400MM), it is to be painted with anti corrosive epoxy
paint.
Operating media : zinc phosphate.
Operating temperature : 80 90 deg C
Insulation: 40mm thick glass wool on sand blasted outside surface
backed by 3 mm thick flexible FRP sheet cladding
7. Phospating tanks - 02 nos.
Note: If there are any deviations from the tendered specifications please mention in remarks column.
5
-
7/28/2019 Annexure i for Specifications of Stands and Tanks
6/6
ANNEXURE - I
SPECIFICATIONS OF STANDS AND TANKS
BIDDERS RESPONSE BIDDERS REMARKS
COMPLIED / NOT
COMPLIED
Heaters : 7.5 kw/230 V/titanium : 4 nos
Sensor : One no. at a corner of the tank encased in a SS 316 tube the
heaters in the tank
V blocks : 2 nos. PP of each tank
Drain outlet : 1 in. PP ball valve
Inside dimensions, mm : 1400 x 700 x 1000(as per the site requirement)
Maximum temperature : 90 deg C
Casing : Inner 1.6 mm CRCA
Outer 1.2 mm CRCA
Insulation : Ceramic wool of 75 mm in the gap between the inner and
outer walls, including the hinged door at the top
Heating : 7.5 kw/230 V/SS/titanium (party may indicate the MOC &
qty)
Air circulation : Blower with motor provided
Painting : Inner chamber - Heat resistant Al. paint
: Exterior - Anti corrosive grey
NOTE: PARTY HAS TO VISIT THE SITE (BDL,BHANUR) BEFORE QUOTE.
8. Hot Air Dryer One No.
Note: If there are any deviations from the tendered specifications please mention in remarks column.
6