  • 4 Henderson Drive, West Caldwell, NJ 07006 Phone: 800-220-4488 Fax: 973-276-0383 Website: www.AlfaWassermannUS.com Email: [email protected]

    ACE Axcel™ Performance Characteristics1

    SA2001SA2001SA2002SA2002SA1046SA1046SA1004SA1004SA1047SA1047SA1007SA1007SA1008SA1008SA2024SA2024 SA1009SA1009SA1010SA1010SA2011SA2011SA2039SA2039SA1012SA1012ACI-32ACI-35SA2013SA2013SA1014SA1014SA2038SA2038SA1044SA2016SA2016SA1017SA3018SA1040SA1040SA1045SA1045SA1019SA2019SA3007SA3007SA1022SA1023SA1023

    serumplasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserumserumserum

    plasmaserum

    plasmaserum

    plasmawhole blood

    serumplasmaserumserumserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    AlbuminAlbumin

    Alkaline PhosphataseAlkaline Phosphatase

    ALTALT

    AmylaseAmylase

    ASTAST

    Bilirubin, DirectBilirubin, Direct Bilirubin, TotalBilirubin, Total

    BUNBUN

    CalciumCalcium

    CholesterolCholesterol

    CKCK

    CO2-LCCO2-LC

    CreatinineCreatinine Direct TIBC

    FerritinGamma-GTGamma-GT

    GlucoseGlucose

    HDL-CHDL-C

    Hemoglobin A1cInorganic PhosphorusInorganic Phosphorus

    Total IronLDH

    LDL-CLDL-CLipaseLipase

    MagnesiumMagnesium

    Total Thyroxine T4Total Thyroxine T4

    Total ProteinTotal Protein Triglycerides

    g/dLg/dLU/LU/LU/LU/LU/LU/LU/LU/L

    mg/dLmg/dLmg/dLmg/dLmg/dLmg/dLmg/dLmg/dLmg/dLmg/dL

    U/LU/L

    mEq/LmEq/Lmg/dLmg/dLμg/dLng/mL

    U/LU/L

    mg/dLmg/dLmg/dLmg/dL

    %mg/dLmg/dLμg/dL

    U/Lmg/dLmg/dL

    U/LU/L

    mg/dLmg/dLμg/dLμg/dLg/dLg/dL

    mg/dL

    Within-RunPrecision%CV2

    ≤1.7≤1.6≤3.2≤1.5≤6.9≤2.9≤3.4≤2.5≤7.1≤3.5≤16.5≤2.4≤10.6≤0.5≤3.3≤6.3≤2.3≤1.2≤2.0≤1.8≤5.2≤2.8≤6.9≤1.3≤9.6≤6.6≤2.2≤4.3≤3.0≤2.0≤1.4≤1.5≤2.7≤2.6≤2.3≤1.9≤5.0≤5.2≤3.1≤4.6≤2.6≤6.5≤5.5≤6.7≤2.8≤4.8≤3.4≤2.4≤0.8≤2.9

    ReportableRange3

    0.3-7.0 g/dL0.3-7.0 g/dL9-1400 U/L9-1400 U/L4 - 480 U/L4 - 480 U/L9-1900 U/L9-1900 U/L4-450 U/L4-450 U/L

    0.1-14.0 mg/dL0.1-14.0 mg/dL0.2-40.0 mg/dL0.2-40.0 mg/dL

    3-100 mg/dL3-100 mg/dL

    0.4-15.0 mg/dL0.4-15.0 mg/dL

    6-600 mg/dL6-600 mg/dL11-1350 U/L11-1350 U/L

    4.0-50.0 mEq/L4.0-50.0 mEq/L

    0.33-25.00 mg/dL0.33-25.00 mg/dL

    52-700 μg/dL11-860 ng/mL

    7-950 U/L7-950 U/L

    4-750 mg/dL4-750 mg/dL8-125 mg/dL8-125 mg/dL

    4.2-13.0%0.4-20.0 mg/dL0.4-20.0 mg/dL12-600 μg/dL

    18-850 U/L4-430 mg/dL4-430 mg/dL15-700 U/L15-700 U/L

    0.4-6.0 mg/dL0.4-6.1 mg/dL1.3-19.6 μg/dL1.3-19.6 μg/dL0.4-14.0 g/dL0.4-14.0 g/dL

    16-1000 mg/dL

    Reportable RangeTolerance Limits4

    ± 5% or 0.5 g/dL± 5% or 0.5 g/dL± 10% or 10 U/L± 10% or 10 U/L± 7% or 10 U/L± 7% or 10 U/L± 10% or 10 U/L± 10% or 10 U/L± 7% or 10 U/L± 7% or 10 U/L

    ± 10% or 0.2 mg/dL± 10% or 0.2 mg/dL± 9% or 0.3 mg/dL± 9% or 0.3 mg/dL± 5% or 3 mg/dL± 5% or 3 mg/dL

    ± 5% or 0.4 mg/dL± 5% or 0.4 mg/dL± 4% or 6 mg/dL± 4% or 6 mg/dL± 10% or 10 U/L± 10% or 10 U/L

    ± 10% or 4 mEq/L± 10% or 4 mEq/L± 5% or 0.1 mg/dL± 5% or 0.1 mg/dL± 8% or 11 μg/dL

    ± 12% or 15 ng/mL± 7% or 5 U/L± 7% or 5 U/L

    ± 5% or 6 mg/dL± 5% or 6 mg/dL± 10% or 3 mg/dL±10% or 3 mg/dL

    ± 5% or 1% HbA1c± 10% or 0.4 mg/dL± 10% or 0.4 mg/dL

    ± 7% or 30 μg/dL± 10% or 10 U/L

    ± 10% or 3 mg/dL± 10% or 3 mg/dL± 10% or 15 U/L± 10% or 15 U/L

    ± 8% or 0.5 mg/dL± 8% or 0.5 mg/dL± 20% or 1.0 μg/dL± 20% or 1.0 μg/dL

    ± 7% or 0.2 g/dL± 7% or 0.2 g/dL± 8% or 7 mg/dL

    Accuracy5:y = mx + b0.996x + 0.030.956x + 0.200.983x + 0.61.017x - 6.51.041x + 0.30.985x - 3.40.958x + 0.70.994x - 1.81.007x + 2.31.001x + 0.2

    0.972x + 0.001.004x + 0.000.966x + 0.011.008x + 0.001.012x + 0.21.007x + 0.31.020x - 0.290.978x + 0.331.012x - 3.30.987x - 1.91.016x - 0.11.006x - 0.5

    0.984x - 0.180.988x - 0.35

    0.979x - 0.0061.003x + 0.009

    0.979x - 2.51.015x - 1.10.984x + 0.10.987x + 4.01.005x - 0.71.003x - 6.60.972x + 0.51.011x - 1.1

    1.012x + 0.101.005x - 0.010.999x + 0.041.006x - 1.81.046x + 4.90.982x - 1.01.006x - 1.6

    0.982x + 3.970.980x - 2.0

    1.046x - 0.180.986x + 0.0251.014x - 0.011.007x + 0.010.990x - 0.030.994x + 0.341.014x - 0.01

    TotalPrecision%CV2

    ≤ 2.0≤ 1.6≤4.4≤5.1≤6.9≤4.1≤3.6≤6.0≤8.5≤4.0≤16.6≤2.4≤10.6≤0.5≤4.6≤6.3≤2.3≤1.4≤2.2≤2.1≤5.5≤5.5≤7.4≤5.0≤9.8≤9.3≤3.3≤6.8≤6.1≤2.4≤1.9≤0.6≤4.8≤3.1≤3.0≤2.5≤6.1≤5.4≤4.6≤4.9≤2.6≤10.7≤6.4≤7.5≤6.8≤4.8≤5.4≤2.9≤1.4≤3.2

    Catalog # Assay Sample Type Units

  • 4 Henderson Drive, West Caldwell, NJ 07006 Phone: 800-220-4488 Fax: 973-276-0383 Website: www.AlfaWassermannUS.com Email: [email protected]

    SA1023SA1025SA1025

    ISEISEISEISEISEISE

    plasmaserum

    plasmaserum

    plasmaserum

    plasmaserum

    plasma

    Triglycerides Uric AcidUric AcidSodiumSodium

    PotassiumPotassium ChlorideChloride

    mg/dLmg/dLmg/dLmmol/Lmmol/Lmmol/Lmmol/Lmmol/Lmmol/L

    Within-RunPrecision%CV2

    ≤1.2≤4.9≤2.8≤1.0≤0.5≤3.5≤1.1≤1.0≤0.5

    ReportableRange3

    16-1000 mg/dL1.5-16.0 mg/dL1.5-16.0 mg/dL40-205 mmol/L40-205 mmol/L1.5-15.0 mmol/L1.5-15.0 mmol/L50-200 mmol/L50-200 mmol/L

    Reportable RangeTolerance Limits4

    ± 8% or 7 mg/dL± 8% or 0.9 mg/dL± 8% or 0.9 mg/dL± 3% or 4 mmol/L± 3% or 4 mmol/L

    ± 0.5 mmol/L± 0.5 mmol/L

    ± 4% or 4 mmol/L± 4% or 4 mmol/L

    Accuracy5:y = mx + b1.007x + 0.011.042x - 0.061.025x - 0.091.008x - 1.341.005x - 2.13

    1.002x + 0.0221.024x -0.0960.970x + 2.281.000x - 0.69

    TotalPrecision%CV2

    ≤3.2≤5.4≤4.5≤1.4≤1.2≤3.5≤1.8≤1.5≤1.4

    ACE Axcel™ Performance Characteristics1

    1 Representative expected performance. See method specific package insert for details.2 Reference: CLSI, Evaluation of Precision Performance of Quantitative Measurement Methods; Approved Guideline-Second Edition CLSI document EP5-A2. CLSI, 940 West Valley Road, Suite 100, Wayne, PA 19087-1898, USA, 2004. (Precision study conducted over 20 days)3 Represents the undiluted sample reportable range. NOTE: For expected values, refer to method specific package insert. IT IS RECOMMENDED THAT EACH LABORATORY DETERMINE THE EXPECTED VALUES FOR ITS PARTICULAR POPULATION.4 Reportable range tolerance limits represent the value expected ± the greater of the two criteria (% or units). These limits may be used when verifying the reportable range.5 Expressed as correlation with ACE® Clinical Chemistry System; plasma correlation vs. serum

    * Typical range; actual range is the value of the low and high calibrators.

    SM466 Rev 5 1014

    Catalog # Assay Sample Type Units

    SM466 ACE Axcel Performance Characteristics Rev 5_pg1SM466 ACE Axcel Performance Characteristics Rev 5_pg2