double wall details - belding tank...one latching 16a relay for automatic fillor empty control. the...

5
Double Wall Leak Detection Alarm Module

Upload: others

Post on 31-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Double Wall Details - Belding Tank...one latching 16A relay for automatic fillor empty control. The optional flashalarm brings attention to level alarm conditions. Package this level

Double WallLeak DetectionAlarm Module

Page 2: Double Wall Details - Belding Tank...one latching 16A relay for automatic fillor empty control. The optional flashalarm brings attention to level alarm conditions. Package this level

Fail-safe relay control of pumps or valves with 0-60•second delay

Optional strobe brings immediate attention to level•alarm conditions

Polypropylene enclosure rated NEMA 4X with swivel•base for conduit alignment

Easy setup with LED indicators for sensor, power and•relay status

Invert switch changes relay state from NO to NC•without rewiring

Switch-Pro LC1X Compact Level Controller®

©2010FlowlineInc.•10500HumboltStreetLosAlamitos,CA90720•562.598.3015•www.flowline.com•DSPRLC1XREVA

Features Key Benefits

The general purpose level controller is offered in two configurationsforpumpandvalvecontrol.TheLC10accepts one level sensor input and provides one 16A relay for high level control or low level control. The LC11 accepts two level sensor inputs and provides one latching 16A relay for automatic fill or emptycontrol.Theoptionalflashalarmbringsattentiontolevel alarm conditions. Package this level controller withourliquidlevelswitchsensorsandfittings.

Application

Compatible Products

IP65

Connects to any Flowline level switch•

Can be installed outdoors in any GP environ-•ment

Interfaces directly with any horn, buzzer, valve,•etc.

UseLC11versionsforautomaticfill/empty•applications

Add strobe for optional visual alarm•

Switch-Tek™ LevelSwitchSensors

LU10LZ12LV10LP15LO10UltrasonicVibrationBuoyancyCapacitanceLeakDetection

LH35LH25Mini-Float HighTempFloat

Page 3: Double Wall Details - Belding Tank...one latching 16A relay for automatic fillor empty control. The optional flashalarm brings attention to level alarm conditions. Package this level

Switch-Pro LC1X Compact Level Controller®

©2010FlowlineInc.•10500HumboltStreetLosAlamitos,CA90720•562.598.3015•www.flowline.com•DSPRLC1XREVA

The level controller is compatible with level1)switch packages (junction box type) and levelswitch sensors.

Specifications

Supplyvoltage: 120/240VAC,50-60Hz

Consumption: 5wattsmaximum

Sensorinputs: LC10:(1)twowire

level switch

LC11:(2)twowire

level switches

Sensorsupply: 13.5VDC@27mA

LEDindication: Sensor,power&relay

Strobetype: -10X1:N/A

-10X2:Xenontube

Strobeflash: -10X1:N/A

-10X2:(1)persecond

Contacttype: LC10:(1)SPDTrelay

LC11:(1)SPDTrelay,

latching

Contactrating: 250VAC@16A

Contactoutput: SelectableNO/NC

Contactdelay: 0-60seconds

Contactlatch: LC10:N/A

LC11:SelectableON/OFF

Ambienttemp.: F:-40°to158°

C:-40°to70°

Enclosurerating:NEMA4X(IP65)

Enclosuremat.: -10X1:PP,UL94VO

-10X2:PP,UL94VO&PC

Conduitentrance:1/2NPT

Enclosuremount:3/4”NPT(3/4”Rp)

Classification: Generalpurpose

Compliance: CE

Approvals: CSA,LR79326

Notes

Ordering

Dimensions

Accessories

Ordering Notes1) The level controller is compatible with level

switch packages (junction box type) and level switch sensors. Contact / input(s) (1)

0 1 Relay / 1 sensor 1 1 Latching relay / 2 sensors

Enclosure mount0 NPT (US)5 Rp (Metric)

Configuration1 2 Controller with Strobe Alert

Level Switch Compact Relay ControllerLC10-11 Series

Switch-Pro

LC1 -10

Controller only

ThecontrollerwithStrobeAlertconfigurationflasheswhen the relay is energized during a high or low level alarm condition.

Strobe Alert

Page 4: Double Wall Details - Belding Tank...one latching 16A relay for automatic fillor empty control. The optional flashalarm brings attention to level alarm conditions. Package this level

IP68

CSA approved intrinsically safe for use in hazardous•environments

SubmersiblepolypropyleneorPFATeflon®sensorand•cable for corrosive liquids

60VA relay selectable NO or NC via power supply wiring•polarity

Compatible with Smart Trak and Switch-Pak installation•fittings

Switch-Tek LU10 Ultrasonic Level Switch®

©2010FlowlineInc.•10500HumboltStreetLosAlamitos,CA90720•562.598.3015•www.flowline.com•DS100510REVA

Features Key Benefits

CSAapproved forhazardousenvironments, the in-trinsically safe ultrasonic point level switch provides reliable liquid level detection of chemical, solvent,hydrocarbon and petroleum based liquids with a 1A relayoutput.Mediaexamples include fuel,acetoneand hydrochloric acid. The submersible polypropyl-ene or PFA liquid level sensor is universally mounted through the tank wall or inside the tank as a high level alarm or low level alarm.

Application

Compatible Products

LCXX

Switch-Pro™ RemoteLevelController

Switch-Pro™ Compact Level Controller

LC1X

Thegeneralpurposelevelcontrollerisofferedintwoconfigurationsforpumpandvalve control. The LC10 accepts one level sensor input and provides one 16A relay for high level control or low level control. The LC11 accepts two level sensor inputs andprovidesonelatching16Arelayforautomaticfilloremptycontrol.Theoptionalflashalarmbringsattentiontolevelalarmconditions.Packagethislevelcontrollerwithourliquidlevelswitchsensorsandfittings.

Application

Available in CSA approved general purpose (LC4X) or isolation (with built-in intrinsic safetybarriers forusewithassociatedapparatus,LC9X)classifications, the levelcontrollerisofferedinthreeconfigurationsforpumpandvalvecontrol.TheLC40/90accepts one level sensor input and provides one 10A relay. The LC41 accepts two levelsensorinputsandprovidesonelatching10Arelayforautomaticfilloremptycontrol.TheLC42/92acceptsthreelevelsensorinputswithonelatching10Arelayoutputforautomaticfilloremptycontrol,andasecondnon-latching10Arelayforhighlevelalarmorlowlevelalarm.Forfieldmountinstallation,addasingleordualindicatorNEMAbox.

Application

Ideal for highly corrosive liquids•

Able to mount through the side wall or top wall•of tank

Compatible with Smart Track or Switch-Pak•mounting options

Useasredundantalarminclassifiedapplica-•tions

Page 5: Double Wall Details - Belding Tank...one latching 16A relay for automatic fillor empty control. The optional flashalarm brings attention to level alarm conditions. Package this level

Switch-Tek LU10 Ultrasonic Level Switch®

©2010FlowlineInc.•10500HumboltStreetLosAlamitos,CA90720•562.598.3015•www.flowline.com•DS100510REVA

Tospecialordera25’(7.6m)or50’(15.2m) 1) levelsensorcable,place thecable lengthat the end of the part number (ie: LU10-1305- 25’).ForPP,add$20for25’(7.6m)or$40for 50’(15.2m)totheprice.ForPFA,add$75for 25’(7.6m)or$150for50’(15.2m)totheprice.TheshortMetriclevelsensorhasconicalRp2)threadsonbothsidesofthewrenchflat.The long Metric level sensor has straight G threads onthesensingsideandconicalRpthreadson thecablesideofthewrenchflat.

Specifications

Orientation: UniversalAccuracy: ± 1mm in waterRepeatibility: ±0.5mminwaterSupplyvoltage: 12-36VDCConsumption: 25mAmaximumContact type: (1) SPST relayContact rating: GP: 60 VA

IS:[email protected]: SelectableNO/NCProcesstemp.: F:-40°to176°

C:-40°to80°Pressure: 150psi(10bar)@

25ºC,[email protected](0.113bar)perºCabove25ºC

Sensorrating: -1XX5:NEMA6(IP68)-2XX5:NEMA4X(IP65)

Sensormaterial: -1XX5:PP-2XX5:PFA

Cablejack.mat.:-1XX5:PP-2XX5:PFA

Cabletype: 4-conductor,#22AWG,shielded

Cablelength: 10’(3m)Processmount: 3/4”NPT(3/4””G/Rp)Mount.gasket: Viton®Classification: IntrinsicallysafeCertificate: CSA,LR79326Compliance: CEApprovals: ClassI,GroupsA,B,C

&D;ClassII,GroupsE,F&G;ClassIII

Parameters: Vmax=32V,Imax=300mA,Pmax=1.3W,Ci=0µF,Li=0µH

Notes

Ordering

Dimensions

Fittings

P/N Description Switch-Pak Single-Point Switch FittingLM45-7001 2”NPTPlug,3/4”NPTAdapter&Nipple,PVCLM45-1001 2”NPTPlug,3/4”NPTAdapter&Nipple,PPLM45-5001 2”NPTPlug,3/4”NPTAdapter&Nipple,PVDF

Smart Trak Multi-Point Switch FittingLM10-1201 2’Track,2”NPTPlug,3/4”NPTNipple,PPLM10-1401 4’Track,2”NPTPlug,3/4”NPTNipple,PPLM10-1601 6’Track,2”NPTPlug,3/4”NPTNipple,PPLM10-1801 8’Track,2”NPTPlug,3/4”NPTNipple,PPLM10-1001 10’Track,2”NPTPlug,3/4”NPTNipple,PPLM10-1101 1mTrack,2”NPTPlug,3/4”NPTNipple,PPLM10-1301 2mTrack,2”NPTPlug,3/4”NPTNipple,PPLM10-1701 3mTrack,2”NPTPlug,3/4”NPTNipple,PP

Smart Trak Level Switch Car KitLM30-1001 SwitchCarKit,3/4”NPT,PolypropyleneLM30-1061 SwitchCarKit,3/4”Rp,PolypropyleneLM52-2890 2”NPTBulkheadFitting,PVC

For optimum performance, install the level sensor using the belowrecommendedordirectequivalentfittings.

Ordering Notes1) To special order a 25' (7.6m) or 50' (15.2 m)

sensor cable, place the cable length at theend of the part number (ie: LU10-1305-25').For PP, add $20 for 25' (7.6m) or $40 for 50'(15.2m) to the price. For PFA, add $75 for 25'(7.6m) or $150 for 50' (15.2m) to the price.

2) The short metric level sensor has conical Rpthreads on both sides of the wrench flat. Thelong Metric level sensor has straight G threads on the sensing side and conical Rp threads on the cable side of the wrench flat.

Sensor material (1)1 PP2 PFA

Sensor length3 Short 4 Long

Process mount (2)0 NPT (US)2 G / Rp (Metric)

Switch-Tek Ultrasonic Level SwitchLU10 Series

LU10- 5

Ultrasonic

0.7"

(19m

m)

2.8"(71mm)

2.1"(54mm)

4.5"(114mm)

3/4" NPT (3/4" G)3/4" NPT (3/4" Rp)

10' Cable (3m)

(+)(-)

NO/NCCOMShld

RedRELAY

BlackWhite

Green

1.3"(32mm)

10' Cable(3m)

0.7"

(19m

m)

0.7"(19mm)

3.0"(76mm)

3/4"NPT(3/4"Rp)

3/4"NPT(3/4"Rp)

(+)(-)

NO/NCCOMShld

RedRELAY

BlackWhite

Green