doppler log jln-205 - jrc · 2017-01-30 · doppler log jln-205 med certificate number :...

4
DOPPLER LOG JLN-205 MED Certificate Number : QQ-MED-39/04-01 Stable & high accurate measurement Easy reading of speed indication

Upload: others

Post on 02-Jan-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Doppler Log JLN-205 - JRC · 2017-01-30 · DOPPLER LOG JLN-205 MED Certificate Number : QQ-MED-39/04-01 Stable & high accurate measurement Easy reading of speed indication E_JLN-205_1128.qxd

DOPPLER LOGJLN-205

MED Certificate Number : QQ-MED-39/04-01

Stable & high accurate measurement Easy reading of speed indication

E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 2

Page 2: Doppler Log JLN-205 - JRC · 2017-01-30 · DOPPLER LOG JLN-205 MED Certificate Number : QQ-MED-39/04-01 Stable & high accurate measurement Easy reading of speed indication E_JLN-205_1128.qxd

Operating Method Dual beam, pulse Doppler sensing

Frequency 2MHz

Speed Range -10.0 to +40.0 knot

Distance-run Range 0 to 99999.99 nm      *Note: NWW-7 optional indicator allows the range from 0 to 9999.99 nm       

Depth Range 3m or more (below hull bottom)

Accuracy +/- 1% or +/- 0.1 knot whichever is greater +/- 1% or +/- 0.1 nm whichever is greater

Indiction Digital indicator Analog indicator (where using option unit of NWW-24 / 25 / 26)

IEC61162-1 Input RMC, RMA or VTG (for SOG indication from GPS receiver)

IEC61162-1 Output 8 port / $VDVBW, $VDVLW sentence

Other Outputs for Analoge indicator: 2 circuits / Pulse for distance-run : 4 circuits /

Contact closure: 1 circuit / for Sub display: 2 circuits / for Distance-run indicator: 1 circuit /

for Remote display: 1 circuit / for Remote diagnostic data port: 1 circuit /

for power fail: 1 circuit

Power Supply 100 / 110 / 115 / 220 / 230 Vac +/- 10%, 50/60Hz, 1-phase

Power Consumption 100VA or less

Operating Temperature -15 to +55 deg. C

S

O

FEATURES

SPECIFICATIONS

M

S

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

The JLN-205 Doppler Log is designed as a device of ship speed measurement and information. The JLN-205 utilizing high frequency of ultrasonic wave brings high stability and accuracy of speed measurement. In addition, a miniaturized transducer will enable to install on the bow where is in less influence against tiny bubbles.

●Ensuring accurate measuring and stable indicating of ship speed since measurement is insensible to bubbles generated in navigation. ●The installation on bow of what is less bubbles influence will be accomplished with a miniaturized transducer. ●The large characters in main display helps easy glance. ●To enable connecting GPS receiver will bring comprehensive speed information calculated by GPS information. ●Various option units can help to configure an optimal Doppler Log system.

C

IMO Resolution A.824(19),Revised IMO Resolution MSC.96(72),IMO Resolution A.694(17). IEC60945:2002,IEC61162-1:2000

This equipment is complied with the following standards.

E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 3

Page 3: Doppler Log JLN-205 - JRC · 2017-01-30 · DOPPLER LOG JLN-205 MED Certificate Number : QQ-MED-39/04-01 Stable & high accurate measurement Easy reading of speed indication E_JLN-205_1128.qxd

     

STANDARD COMPONENTS

OPTION COMPONENTS

Normal viewer with large charactor with instruction comment graphic viewer

Main Display can provide suitable viewer from various screen types.

Sub Display(Option) NWW-65S

Analog Indicator(Option)    NWW-24

Main Display NWW-65 Remote Display(Option)   NWW-16

Remote Display(Option) NWW-5

Data Distributor NQA-4288

Signal Processor NJC-25

Transducer NKF-547

or

Ship's mainMax 500m

Transducer Gate-valve type (Option) NKF-531E

No. NAME TYPE Q'TY REMARKS

 1  Main Display NWW-65 1 Desktop,(Flush mounting kit : option), with a cable of 5m length

 2  Data Distributor NQA-4288 1

 3  Signal Processor NJC-25 1 IPx5

 4  Transducer  NKF-547 1 With a cable of 30m length

 5  Spare Parts 7ZXBS0020 1

 6  Instruction Manual 7ZPBS2803    

No. NAME TYPE Q'TY   REMARKS

 1  Sub Display NWW-65S Max. 2

 2  Analog Indicator NWW-24    Flush mouting

 3 NWW-25 Max. 2 Bulkhead mounting / Waterproof

 4 NWW-26 Panel mounting

 5  Remote Indicator NWW-5

 6  Remote Indicator NWW-16

 7  Distance-run Indicator NWW-7 Max. 1 Ship's speed (fore / aft) / Distance-run / Indication range: 9999.99 nm

 8  Dimmer Unit NCM-227D - For main / sub display

 9 NCM-329 - For analog indicator

10 NCM-227 - For remote indicator

11  Connection Box NQD-2025 1 for extension between NWW-65 and NQA-4288

12  Transducer (Gate-valve type) NKF-531E 1 With a cable of 25m length

13  Flush mounting kit MPTG30432 - for Main / Sub Display

Distance-run Indicator(Option) NWW-7

CONNECTION DIAGRAM

Max. 1Ship's speed (fore / aft)

Ship's speed (fore / aft) / Distance-run / Indication range: 9999.99 nm

E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 4

Page 4: Doppler Log JLN-205 - JRC · 2017-01-30 · DOPPLER LOG JLN-205 MED Certificate Number : QQ-MED-39/04-01 Stable & high accurate measurement Easy reading of speed indication E_JLN-205_1128.qxd

StaEas

DIMENSIONS

Main Display NWW-65 Main Display Flush-mounting type (NWW-65)

Data Distributor NQA-4288

Transducer NKF-547

Signal Processor NJC-25

CLR OFF

PWR OFF

MODE

JLN-205

CONT DIM

(46.5) 197 104 46.5

21

138 117

DOPPLER LOG

CABLE INLET

28 96 124

55

PUSH

CLR OFF

PWR OFF

MODE

PUSH

DOPPLER LOG JLN-205

CONT DIM

117

197 WALL

CABLE INLET

11.5 27 70

130

470

300

4-R4.5

420

490

240

CABLE INLET

警告 WARNINGこのカバーをはずすな 感電の恐れあり

HIGH VOLTAGEDO NOT REMOVETHE COVER.

MADE IN JAPAN

NB 0191-**

380

360

220 123

310

280

φ13~φ18

CABLE INLET

4-R4.5

XXXXXXX DATE

XXXXXXX

SIGNAL PROCESSOR

COMPASS SAFE DISTANCE

SERIAL NO.

MODEL

3.0m

NJC-25

警告 WARNINGこのカバーをはずすな 感電の恐れあり

HIGH VOLTAGEDO NOT REMOVETHE COVER.

MADE IN JAPAN

SEAWATER AREA

SEPARATE FROM POWER CABLE

SHEET PACKING

4-M16×40BOLT SPRING LOCK WASHER

CABLE φ13.2

(10K-32) (SHIP YARD)

(MOUNTING HOLE φ137)

FLANGE JIS B 2220

CFT-022B-30

(SHIP YARD)

(SHIP YARD)

(SHIP YARD)

(SHIP YARD)

PIPING

130

φ50

φ100

(2)

(16)

26

φ135 ±1

RED

WHITE

BOW MARK

BOW MARK(TRANSDUCER)

BOW

10゚

WELD

(SHIP YARD) WELD DO NOT PAINT THIS

RADIATION SURFACE

INSTALL UNDER AN ANGLE OF ±5° DEGREES TO THE BOW-STERN DIRECTION

Unit:mm Weight:0.8kg Unit:mm Weight:0.8kg

Unit:mm Weight:6kg Unit:mm Weight:10kg

Unit:mm Weight:17kg

For further information, contact:

Since 1915

Main Office:

Overseas Branches : Seattle, Amsterdam, Athens, Manila Liaison Offices : Taipei, Jakarta, Singapore, Hanoi,

Shanghai, Hamburg, New York

28EM ISO9001,ISO14001 Certified

●Specifications may be subject to change without notice.

URL eng

Printed in Japan2005.4 CAT.No.Y14-197(No.849-7-2)D2011.12

Fujisawa bldg. 30-16, Ogikubo 4-chomeSuginami-ku, Tokyo 167-8540, JapanTelephone: +81-3-6832-1816Facsimile: +81-3-6832-1845

E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 1