dn70305645 2 en global pdf online a4
DESCRIPTION
Nokia Flexy2TRANSCRIPT
-
Installing Flexi WCDMA BTSModules for Stack, Wall, and PoleConfigurations
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 1 (97)
471449A.505Nokia Flexi WCDMA Base Station, Rel. FlexiWBTS4.0, Product Documentation, v.1
-
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.
The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given as is and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2007. All rights reserved.
2 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Contents
Contents 3
1 Summary of changes in Installing Flexi WCDMA BTS Modules forStack, Wall, and Pole Configurations 5
2 Handling the modules and unpacking the delivery 7
3 Installing Nokia Flexi WCDMA BTS stand-alone 9
4 Preparing the modules for a stand-alone installation 11
5 Lifting the stand-alone BTS 13
6 Grounding principle of the stand-alone BTS 17
7 Installing the stand-alone BTS on the floor 217.1 Anchoring the plinth on the floor 217.2 Installing modules on the floor 25
8 Fixing adapter mechanics to plinth 31
9 Mounting the stand-alone BTS on the wall 379.1 Mounting the plinth on a wall 379.2 Mounting modules on a wall 41
10 Mounting the stand-alone BTS on the pole 4910.1 Mounting the plinth on a pole 4910.2 Mounting modules on a pole 53
11 Installing transmission sub-module 61
12 Installing Remote Radio Head 6512.1 Installing Remote Radio Head to a pole 6512.2 Installing Remote Radio Head to a wall 70
13 Checklist for installing modules 77
Appendix A Contents of deliveries 79A.1 Contents of the System Module delivery 79A.2 Contents of the RF Module delivery 80A.3 Contents of the mounting kit for floor, wall and pole (FMFA) delivery 81A.4 Contents of the pole mounting kit delivery (optional) 82A.5 Contents of the transmission sub-module deliveries 83A.6 Contents of the transmission cable deliveries 89
Appendix B Installation tools and torque values 91B.1 BTS installation tools and equipment 91B.2 Torque values 91
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 3 (97)
Contents
-
Appendix C FTOA optical interface (SFP) requirements 94C.1 FTOA optical interface (SFP) requirements 94
4 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
1 Summary of changes in Installing FlexiWCDMA BTS Modules for Stack, Wall,and Pole Configurations
Changes between issues 1-0 and 2-0
The name of the document changed from Installing the Modules toInstalling Modules for Stack, Wall, and Pole Configurations.
A figure showing how to fix the adapter mechanics when installing twoplinths on a pole added to section Fixing adapter mechanics to plinth.
A figure showing the correct installation orientation added to sectionMounting modules on a wall.
Table Accepted GE SFPs added to section Installing transmission sub-module.
Section Installing Remote Radio Head to a pole added.
Section Installing Remote Radio Head to a wall added.
Section Contents of the transmission cable deliveries added.
Section Contents of the transmission sub-module deliveries updated withinformation on the FTJA sub-module.
The structure of the document slightly changed.
Improvements to figures made.
Warnings, cautions, and notes edited.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 5 (97)
Summary of changes in Installing Flexi WCDMA BTS Modules forStack, Wall, and Pole Configurations
-
6 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
2 Handling the modules and unpacking thedelivery
Before you start
Caution
Electrostatic discharge (ESD) may damage the modules. Wear an ESDwrist strap or use a corresponding method when handling the modules.
Figure 1. Connecting the antistatic wrist strap
to ESD stud
Wrist strap
DN7050727
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 7 (97)
Handling the modules and unpacking the delivery
-
Summary
Unpack and check the delivery carefully before the installation to makesure that all the required items are available and undamaged.
Steps
1. Carefully check the contents of the delivery.
2. Remove the items from the package.
3. Check that the delivery is complete and undamaged.
4. Recycle the packaging material.
5. Proceed to the module installation procedure.
8 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
3 Installing Nokia Flexi WCDMA BTSstand-alone
Purpose
This section provides an overview of the main tasks of the Nokia FlexiWCDMA BTS installation process. For more detailed information on theinstallation phases, see the appropriate chapters.
Steps
1. Unpack and check the delivery.
2. Install the plinth.
3. Connect the plinth to the site main ground.
4. Install the modules.
5. Ground the modules.
6. Connect the necessary cables.
7. Commission the BTS.
8. Complete the installation.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 9 (97)
Installing Nokia Flexi WCDMA BTS stand-alone
-
10 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
4 Preparing the modules for a stand-aloneinstallation
Purpose
Fix the module back covers, and external cables entries before theinstallation (except for the System Module).Summary
Figure 2. Preparing a module for installation
DN7050715
23
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 11 (97)
Preparing the modules for a stand-alone installation
-
Steps
1. Fix the safety catch (pole or wall installation only).
For safety catch fixing instructions, see Installing covers in wall andpole installations.
2. Fix the module back cover with two screws.
3. Fix the two external cable entries with two screws each.
12 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
5 Lifting the stand-alone BTSPurpose
Follow these instructions when a stand-alone BTS must be lifted to thedesired installation location.
Before you start
There are two options as to how to lift a stand-alone BTS:
. A stand-alone BTS can be lifted stacked (max. two modules perplinth) and cabled. See Installing modules on the floor for installationinstructions and Cabling the BTS and Creating Configurations forcabling instructions. When lifting a stacked BTS, the lifting points onthe plinth must be used.
. The plinth can be lifted and mounted first and then each modulelifted separately. When lifting a single module, a lifting bag must beused.
Warning
The equipment is heavy. Take care when lifting it.
Caution
The rear stopper is fragile. Do not attempt to lift the plinth using the rearstopper.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 13 (97)
Lifting the stand-alone BTS
-
Caution
The cable support plates on the sides of the module casings are fragile.Do not attempt to lift the module casing using the cable support plates.
Steps
1. Attach the lifting eye bolts to the attachment points in the plinth.
Lifting eye bolts (M12) are not included in the delivery. You can orderthe LEKA kit separately from your Nokia supplier.
2. Attach the hoisting belt or the rope to the lifting eye bolts.
Attach the hoisting belt or rope so that the angle between the belt orrope and the plinth is minimum 60. The distance between the plinthand the belt or rope is minimum 400 mm.
14 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 3. Lifting the stand-alone BTS
3. Lift the BTS carefully to the desired installation height.
4. Mount the BTS.
5. Remove the lifting equipment.
DN7096814
60 400mm
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 15 (97)
Lifting the stand-alone BTS
-
16 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
6 Grounding principle of the stand-aloneBTS
Before you start
A site grounding cable is not included in the delivery. Make sure you havethe necessary grounding cables. Do not chain grounding cables.
Note
When modules are installed inside a cabinet, no separate earthing(grounding) cable for the modules is required. The cabinet providesadequate earthing (grounding).
Note
If the base transceiver station (BTS) has more than one plinth, connectthe main earth (ground) to one of the plinths and earth (ground) all themodules to that plinth. Alternatively, earth (ground) the modules to theirown plinths and then connect the plinths to the main earth (ground).
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 17 (97)
Grounding principle of the stand-alone BTS
-
Summary
Figure 4. Connecting the grounding cables to modules
Steps
1. Ground the plinth to the site main ground.
2. Connect the grounding cable to the grounding point in themodule front panel.
3. Route the grounding cable through the cable entry.
4. Connect the other end of the cable to the grounding point in theplinth.
5. Repeat steps 2-4 for each module.
DN7037752
System Modulecable entry
RF Modulecable entry
AC/DC power modulegrounding
Modules groundingpoints
1
2
3
4
6
18 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
6. Fix the excess cables to the cable support plates with cableties.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 19 (97)
Grounding principle of the stand-alone BTS
-
20 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
7 Installing the stand-alone BTS on thefloor
7.1 Anchoring the plinth on the floor
Purpose
The plinth is mandatory when the modules are not mounted in an optionalcabinet or 19" rack.
Before you start
. When choosing the location for the plinth, take into consideration therequired maintenance space. See figure Anchoring plinth on basewith maintenance space in the back for details.
. If there are more than five modules in a stack, side access to theback is needed for back maintenance.
See the following figures for clearances and Earthquake Zones 2and 4 mounting holes.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 21 (97)
Installing the stand-alone BTS on the floor
-
Figure 5. Plinth anchoring points, minimum clearances
DN70131327
145mm
(5.7
in.)
360mm
(14.1
in.)
300 mm(11.8 in.)
13.5 mm(0.5 in.)(4 pcs)
Facility wall
75 mm(3.0 in.)
75 mm(3.0 in.)
Cover
Mounting holes
(EarthquakeZone 2 & 4)
Plinth
Front
Mounting holes
(EarthquakeZone 2 & 4)
A
B
Option A is for stack configuration
22 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 6. Anchoring plinth on base with maintenance space in the back
Steps
1. Turn the rear stopper.
2. Place the plinth on the floor, grounding points facing forward,rear stopper against the wall if back access is not required.
a. Remove the front cover of the plinth to access the two frontmounting holes.
b. Remove the six rubber seals.c. Check if the floor is level. If the floor is not level, install shims.
DN7038966
Fan maintenancespace
305 mm (12 in.)Plinth
360mm
(14.1
in.)
300 mm(11.8 in.)
13.5 mm(0.5 in.)(4 pcs)
75 mm(3.0 in.)
Facility wall
75 mm(3.0 in.)
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 23 (97)
Installing the stand-alone BTS on the floor
-
Figure 7. Plinth installation position
3. Anchor the plinth on the floor.
Anchor the plinth on the floor with 4 anchoring bolts, 12 mm (0.47 in.)in diameter, and tighten it to 49 Nm.
Note
The plinth must be fixed to the floor to meet the Earthquake Zone 4requirement.
Further information
Next, ground the plinth to the site main ground. For more information, seeGrounding principle of the stand-alone BTS.
DN7038954
24 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
7.2 Installing modules on the floor
Purpose
The stand-alone BTS (without a cabinet) can be installed on the floor in astack of up to nine modules (maximum height 27U). To meet theearthquake requirement for Zone 4, no more than five modules (maximumheight 15U) can be installed in one stack. More than six modules in a stackmeets the vibrational requirements for earthquake Zone 2.
Tip
The four module fixing screws between the module core and themodule casing must be tightened to 5 Nm.
Before you start
Check that
. the plinth is installed as instructed in the Anchoring the plinth on thefloor section
. the plinth is grounded.
If you are going to install Flexi Power Module (FPMA), its recommendedposition is at the bottom of the module stack. For more information onFPMA installation, see Installing Flexi Power Module (FPMA).
Tip
Connect the DC input cable and install the transmission sub-modulebefore the System Module installation.
The recommended module installation order is illustrated in the followingfigure.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 25 (97)
Installing the stand-alone BTS on the floor
-
Figure 8. Recommended module installation order
Summary
RF Module
RF Module
System Module
RF Module
Power Module(optional)
DN7038978
Plinth
System extensionmodule (optional)
Transmissionsub-module
26 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 9. Installing modules on the floor
7
1
8
1
5
1
3
4
DN7037667
1
2
1
6
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 27 (97)
Installing the stand-alone BTS on the floor
-
Steps
1. Align the holes on the first module bottom with the fixing studson the plinth.
Tip
Line up the locating marks on the side of the module to help aligning theholes with fixing studs.
2. Align the module markings and push the module back until itstops.
3. Attach the module to the plinth with screws.
4. Connect the module grounding cable between the module frontpanel and the plinth.
See Grounding principle of the stand-alone BTS for moreinformation.
5. Align the holes on the second module bottom with the fixingstuds on the first module.
6. Push the module back until it stops.
7. Attach the modules to each other with screws.
8. Connect the module grounding cable between the module frontpanel and the plinth.
9. Repeat the steps for each subsequent module.
Expected outcome
The following figure illustrates an example of the basic configuration of oneSystem Module and three RF Modules installed on the floor.
28 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 10. Installation example: modules on the floor
DN7037655
1
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 29 (97)
Installing the stand-alone BTS on the floor
-
30 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
8 Fixing adapter mechanics to plinthPurpose
Adapter mechanics brackets are installed on the plinth in wall and poleinstallations.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 31 (97)
Fixing adapter mechanics to plinth
-
Summary
Figure 11. Fixing adapter mechanics to plinth (right-hand installation)
Bottom
1
fix the screws, do not tighten yet2
DN7037043
Torque value: 10 Nm
thread locking compound
32 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 12. Fixing adapter mechanics to plinth (left-hand installation)
Tip
Right-hand installation is the recommended installation option.
Bottom
fix the screws, do not tighten yet2
DN70102874
1
Torque value: 10 Nm
thread locking compound
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 33 (97)
Fixing adapter mechanics to plinth
-
Steps
1. Fix the upper bracket of the adapter mechanics on the plinthwith three screws.
Tighten the screws to 10 Nm.
In pole installations, if you are installing modules on both sides of thepole, make sure you install the upper bracket on the opposite side ofeach plinth so that the plinths are facing the same direction.
Warning
Risk of physical injury. Secure the screws with a thread-lockingcompound in pole and wall installations.
DN70319067
34 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
2. Fix the lower bracket of the adapter mechanics on the plinthwith three screws. Do not tighten the screws yet.
When the screws are left loose at this point, it allows the plinth tomove slightly and prevents twisting in the installation phase.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 35 (97)
Fixing adapter mechanics to plinth
-
36 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
9 Mounting the stand-alone BTS on thewall
9.1 Mounting the plinth on a wall
Purpose
A plinth is required for mounting the modules on a wall.
Before you start
Check that the plinth adapter mechanics are installed as instructed in theFixing adapter mechanics to plinth section.
If installing additional plinths one upon the other, the distance between theupper mounting screw holes in first and second plinth must be 550 mm(21.7 in.) minimum.Summary
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 37 (97)
Mounting the stand-alone BTS on the wall
-
Figure 13. Mounting the plinth on a wall
2
5
6 tighten the screws
3
4
1
DN7037067
185 mm
482,5
mm
38 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Steps
1. Mark the mounting screw locations on the wall and drill theholes for the screws.
2. Fix the upper mounting screws to the wall, lift the plinth on thewall and fit it to the mounting screws.
Check that the plinth is level.
3. Tighten the upper mounting screws.
4. Insert the lower mounting screws.
5. Tighten the lower mounting screws.
6. Make sure that the plinth is not twisted.
When the plinth is in a correct position, tighten the three screws inthe lower bracket of the adapter mechanics.
7. In case you are installing more than one plinth, repeat steps 1-6for each plinth.
Note that the required space between the plinths is 100 mm.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 39 (97)
Mounting the stand-alone BTS on the wall
-
Figure 14. Mounting a second plinth on the wall
Further information
Next, ground the plinth to the site main ground. For more information, seeGrounding principle of the stand-alone BTS .
DN7047057
185 mm (7.3 in)
600mm
(23.6
in)
482,5
mm
(19.0
in)
The distance between the twoplinths must be 100 mm (3.9 in) 185 mm (7.3 in)
40 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
9.2 Mounting modules on a wall
Purpose
The stand-alone BTS can be installed on a wall. The maximum number ofmodules per plinth is two.
Note
To meet the earthquake requirement Telcordia GR-63-CORE and thevibrational requirements for Earthquake Zone 4, the four module fixingscrews between the module core and the module casing must betightened to 5 Nm.
Before you start
Check that:
. the plinth is installed as instructed. See Mounting the plinth on a wallfor plinth installation instructions.
. the plinth is grounded.
. there is one plinth per two modules.
If you are going to install Flexi Power Module (FPMA), it should beinstalled on the same plinth as the System Module. For more informationon FPMA installation, see Installing Flexi Power Module (FPMA).
The recommended module installation order is illustrated in the followingfigure.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 41 (97)
Mounting the stand-alone BTS on the wall
-
Figure 15. Recommended module installation order
RF Module
RF Module
RF Module
Plinth
Wall
DN7055446
System Module
Power Module(optional)
42 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Summary
Caution
Excess torsion damages the casings. In wall and pole installation, donot install more than two modules per plinth.
Caution
Incorrect installation may lead to damage to the modules. The modulesmust be installed with the front panels facing left or right. Do not installthe modules with the front panels facing up or down.
DN70360702
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 43 (97)
Mounting the stand-alone BTS on the wall
-
Figure 16. Mounting the modules on the wall
5
1
3
DN7037079
Line up thelocating marks
Line up thelocating marks
6
2 4
8
7
9
44 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Steps
1. Align the holes on the first module's bottom with the fixingstuds on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning theholes with fixing studs.
2. Push the module back until it stops.
3. Attach the module casing to the plinth with two screws.
Secure with thread locking compound.
4. Connect the module grounding cable between the module frontpanel and the plinth.
See Grounding principle of the stand-alone BTS for moreinformation.
5. Align the holes on the second module's bottom with the fixingstuds on the first module.
6. Push the module back until it stops.
7. Attach the module casings to each other with two screws.
Secure with thread locking compound.
8. Connect the module grounding cable between the module frontpanel and the plinth.
9. Attach the fixing plates across the module casings on bothsides of the modules and fix with six screws and springwashers.
Secure with thread locking compound.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 45 (97)
Mounting the stand-alone BTS on the wall
-
Figure 17. Installing fixing plates for the casing
10. Repeat the steps above to install the remaining modules to aseparate plinth or plinths.
One plinth can have two modules installed. A configuration of oneSystem Module and three RF Modules therefore requires twoplinths.
DN70144135
46 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Expected outcome
The following figure illustrates one example of the basic configuration ofone System Module and three RF Modules installed on the wall. Theinstallation in the figure is a right-hand installation, but the BTS can also beinstalled as a left-hand installation.
Tip
Right-hand installation is recommended.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 47 (97)
Mounting the stand-alone BTS on the wall
-
Figure 18. Installation example: modules on the wall
min 100 mm(3.9 in.)
DN7037094
48 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
10 Mounting the stand-alone BTS on thepole
10.1 Mounting the plinth on a pole
Purpose
A plinth and pole mounting kit are required for mounting modules on apole. In pole installation, one plinth can have maximum two modulesinstalled. If the configuration has more than two modules, additional plinthsmust be installed. Two plinths can be installed on one pair of mountingbrackets (on opposite sides of the pole).Before you start
Check that the plinth adapter mechanics are installed as instructed in theFixing adapter mechanics to plinth section.
There are three different lengths of bolts available and four places for thebolts in the pole mounting brackets. When attaching the brackets to thepole, use the shortest possible bolts and the holes whose distance is theclosest to the pole diameter. See the following table and figure for moredetails.
Table 1. Pole mounting brackets bolt lengths, hole numbers and torquevalues
Pole diameter Bolt length Hole number* Torque value
60-90 mm 120 mm 1 29 Nm
95 - 125 mm 120 mm 2 29 Nm
126 - 165 200 mm 1 29 Nm
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 49 (97)
Mounting the stand-alone BTS on the pole
-
Table 1. Pole mounting brackets bolt lengths, hole numbers and torquevalues (cont.)
Pole diameter Bolt length Hole number* Torque value
166 - 210 200 mm 2 29 Nm
211 - 255 300 mm 3 29 Nm
256 - 300 300 mm 4 29 Nm
*Hole numbering is presented in the following figure.
Figure 19. Pole mounting bracket hole numbering
Summary
4 3 2 1 4321
DN7038015
50 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 20. Mounting the plinth on a pole
2
1
3
4
6tighten the screws
5
DN7037101
7
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 51 (97)
Mounting the stand-alone BTS on the pole
-
Steps
1. Fix the upper pole mounting bracket on the pole and attach themounting screws on the bracket.
Make sure that the mounting screws in the upper pole mountingbracket are on the lower edge of the bracket. Attach the screwsloosely at this point.
2. Fix one half (the one with threads) of the lower pole mountingbracket on the plinth adapter mechanics with the mountingscrews.
Make sure that the mounting screws in the lower pole mountingbracket are in the upper edge of the bracket.
3. Lift the plinth on the pole and fit it to the pole mountingbracket's mounting screws.
See Lifting the stand-alone BTS for lifting instructions.
4. Tighten the mounting screws.
5. Place the counterpart of the lower pole mounting bracket in itsplace and tighten the screws.
6. Make sure that the pole mounting brackets are aligned and theplinth is not twisted.
When the plinth is in a correct position, tighten the three screws inthe lower bracket of the adapter mechanics.
7. If a second plinth is required, install it on the other side of thepole mounting bracket (if there is enough space).
a. Fix the adapter mechanics on the plinth as described in Step 1above.
b. Fix the mounting screws on the upper pole mounting bracket.c. Lift the plinth on the pole and fit it to the pole mounting
bracket's mounting screws and tighten the screws.d. Insert the lower fixing screws to fix the plinth on the lower pole
mounting bracket. Tighten the mounting screws.e. Make sure that the plinth is not twisted. When the plinth is in a
correct position, tighten the two remaining screws in the lowerbracket of the adapter mechanics.
52 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Further information
Next, ground the plinth to the site main ground. See Grounding principle ofthe stand-alone BTS.
10.2 Mounting modules on a pole
Purpose
Note
To meet the earthquake requirement for Zone 4, the four module fixingscrews between the module core and the module casing must betightened to 5 Nm.
Tip
Perform the installation as completely as possible before lifting themodules especially when installing the BTS to a high location.
Before you start
Check that:
. the plinth is grounded.
. one mounting plinth per two modules is installed on a pole. SeeMounting the plinth on a pole for plinth installation instructions.
When using screws to fix a casing to casing, plinth to casing, or plinth topole, the screws must be secured with a thread-locking compound.
If you are going to install Flexi Power Module (FPMA), it should beinstalled on the same plinth as the System Module. For more informationon FPMA installation, see Installing Flexi Power Module (FPMA).
The recommended module installation order is illustrated in the followingfigure.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 53 (97)
Mounting the stand-alone BTS on the pole
-
Figure 21. Recommended module installation order
RF Module
System Module
Power Module(optional)
Plinth
Plinth
Pole
DN7056336
RF Module
RF Module
54 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Summary
Caution
Excess torsion damages the casings. In wall and pole installation, donot install more than two modules per plinth.
Caution
Incorrect installation may lead to damage to the modules. The modulesmust be installed with the front panels facing left or right. Do not installthe modules with the front panels facing up or down.
1
3
Line up thelocating marks
Line up thelocating marks
24
DN7037113
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 55 (97)
Mounting the stand-alone BTS on the pole
-
Figure 22. Mounting the modules on a pole
Steps
1. Align the holes on the first module's bottom with the fixingstuds on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning theholes with fixing studs.
2. Push the module back until it stops.
3. Attach the module casing to the plinth with screws and springwashers.
Secure with thread locking compound.
7
Line up thelocatingmarks 10
DN7056721
8
6
9
56 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
4. Connect the module grounding cable between the module frontpanel and the plinth.
See Grounding principle of the stand-alone BTS for moreinformation.
5. Align the holes on the second module's bottom with the fixingstuds on the first module.
Tip
Line up the locating marks on the side of the module to help aligning theholes with fixing studs.
6. Push the module back until it stops.
7. Attach the module casings to each other with screws andspring washers.
Secure the screws with thread locking compound.
8. Connect the module grounding cable between the module frontpanel and the plinth.
9. Attach the fixing plates across the module casings on bothsides of the modules and fix with six screws and springwashers.
Secure with thread locking compound.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 57 (97)
Mounting the stand-alone BTS on the pole
-
Figure 23. Installing fixing plates for the casing
10. Repeat the steps above to install the remaining modules to aseparate plinth.
One plinth can have a maximum of two modules installed. Aconfiguration of one System Module and three RF Modules thereforerequires two plinths.
DN70144135
58 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Expected outcome
The following figure illustrates an example of the basic configuration of oneSystem Module and three RF Modules installed on a pole. The installationin the figure is a right-hand installation, however, the BTS can also beinstalled as a left-hand installation.
Figure 24. Installation example: modules on the pole
DN7037125
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 59 (97)
Mounting the stand-alone BTS on the pole
-
60 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
11 Installing transmission sub-modulePurpose
The transmission sub-module is chosen based on the transmissionrequirements of each site.
Before you start
The System Module has to be powered off before installing or changingthe transmission sub-module.
Summary
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 61 (97)
Installing transmission sub-module
-
Figure 25. Installing transmission sub-module to System Module
Steps
1. Detach the System Module external cable entries (2 pcs).
DN7037191
3
4
6
8
check that the connectoris straight
1
2
5
7
62 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
2. Loosen the core fixing screws (4 pcs).
3. Pull the System Module core out of the casing.
4. Remove the rubber plug.
5. Insert the FCM-FTM connection card.
The FCM-FTM connection card is asymmetric. It is positioned sothat the broad side is connected to the System Module and thenarrow side is connected to the transmission sub-module.
6. Check that the FCM-FTM connection card on the SystemModule is straight.
7. Align the transmission sub-module with the two guide pins inthe System Module, and push the sub-module in place.
8. Fix the transmission sub-module with 4 x M5x25 screws andtighten to 4.0 Nm.
9. Re-insert the module core.
10. If your transmission sub-module is either FTIA, FTJA, or FTOA,do one of the following:. FTIA: insert a SFP Ethernet transceiver (not included in the
delivery) into the GE slot.See the following table for accepted GE SFPs.
Table 2. Accepted GE SFPs
Code Product Manufacturer ID Manufacturer's type
4808666 SFP GbE Cat5 100m,RJ45 (for debug only)
Finisar FCLF-8521-3
4807974 SFP GbE 1310nm SM10km LC, LX
Finisar FTLF1319P1BTL
no MCOMPO SFP SFP GbE 850nm MM LC,SX
Finisar FTLF8519P2BTL
. FTJA: Insert the SFP transceiver to the EIF1 slot.
. FTOA: Insert the SFP SDH transceiver to the FTOA. Seesection FTOA optical interface (SFP) requirements inAppendix C.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 63 (97)
Installing transmission sub-module
-
The SFP transceiver is optional for the FTIA and FTJA, andmandatory for the FTOA.
11. Make sure that the cable connector seals are firmly in place.
64 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
12 Installing Remote Radio Head12.1 Installing Remote Radio Head to a pole
Purpose
Remote Radio Head is installed to a pole using Flexi Pole Kit (FPKA).Steps
1. Fix the upper mounting bracket on the pole and attach themounting bracket screws on the bracket.
2. Fix one half of the lower mounting bracket on the Remote RadioHead.
1
DN70414583
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 65 (97)
Installing Remote Radio Head
-
3. Lift the module on the pole and fit it to the mounting screws ofthe pole mounting brackets.
4. Tighten the mounting screws to 30 Nm.
Make sure that the brackets are carefully aligned so that the moduledoes not get twisted during installation.
5. Place the counterpart of the lower pole mounting bracket in itsplace.
DN70414595
2
3
DN70414602
3
4
66 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Tighten the screws.
6. Detach the IP cover at the bottom.
7. Connect the grounding cable to the bottom of the Remote RadioHead.
DN70414614
5
DN70414723
6
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 67 (97)
Installing Remote Radio Head
-
8. Connect the two antenna jumper cables.
9. Strip the DC cable as needed.
10. Connect the DC cable.
Connect the black wire to the terminal marked with a plus sign (+)and the blue wire to the terminal marked with a minus sign (-).
11. Install the SFP.
DN70420998
7
8
DN70420986
10
68 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
12. Connect the optical cable.
Fix it with a cable tie to the cable tie point on the left side.
13. Replace the IP cover.
When inserting the IP cover, make sure that the gaskets at thebottom of the cover are properly fitted in the slots. Fix with fourscrews.
DN70421007
10
11
12
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 69 (97)
Installing Remote Radio Head
-
12.2 Installing Remote Radio Head to a wall
Steps
1. Mark the mounting hole locations on the wall and drill the holesfor the screws (or any other fixing method).
DN70421019
13
70 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
2. Fix the upper mounting screws to the wall.
3. Lift the Remote Radio Head on the wall and fit it to the mountingscrews.
Tighten the screws.
4. Insert the lower mounting screws.
1
DN70421022
3
185mm(7.3 in.)
700mm(27.6 in.)
DN70421046
4
5
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 71 (97)
Installing Remote Radio Head
-
5. Tighten the screws.
6. Detach the IP cover at the bottom.
7. Connect the grounding cable to the bottom of the Remote RadioHead.
DN70421058
6
72 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
8. Connect the two antenna jumper cables.
9. Strip the DC cable as needed.
10. Connect the DC cable.
Connect the black wire to the terminal marked with a plus sign (+)and the blue wire to the terminal marked with a minus sign (-).
11. Install the SFP.
DN70421073
7
8
DN70421085
10
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 73 (97)
Installing Remote Radio Head
-
12. Connect the optical cable.
Fix it with a cable tie to the cable tie point on the left side.
13. Replace the IP cover.
When inserting the IP cover, make sure that the gaskets at thebottom of the cover are properly fitted in the slots. Fix with fourscrews.
DN70421097
10
1112
74 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
DN70421116
13
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 75 (97)
Installing Remote Radio Head
-
76 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
13 Checklist for installing modulesWork phase Checked
Delivery is complete and undamaged.
Minimum clearances are met.
Plinth is grounded.
Transmission sub-module is installed according to theinstructions.
Modules are installed according to instructions.
Modules are grounded to the plinth.
Cable entries are installed.
Cable connector seals are firmly in place.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 77 (97)
Checklist for installing modules
-
78 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Appendix A Contents of deliveries
A.1 Contents of the System Module delivery
The System Module delivery contains the following items:
. System Module
. 2 x System Module cable entries
. ESD wrist strap
. 2 x cable clamps
. Stress relief plate for the power cable
. 4 x M5 screws for fixing cable entries to the casing
. 4 x K30 screws for the cable clamps
. 2 x M5 screws for fixing the casing to another casing or plinth
. 20 x cable ties
. Flexi WCDMA BTS Quick Guide
Note
The transmission sub-module is not included in the delivery package. Itmust be ordered separately. Make sure you have the correct type ofsub-module.
See the following figure for more information on the delivery contents.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 79 (97)
Contents of deliveries
-
Figure 26. Delivery contents of the System Module
A.2 Contents of the RF Module delivery
The RF Module delivery contains the following items:
. RF Module
. 2 x RF Module cable entries
. Optical cable
. Power cable
. 2 x optical transceivers
. 4 x M5 screws for fixing cable entries to the casing
. 2 x M5 screws for fixing the casing to another casing or plinth
. 10 x cable ties
See the following figure for more information on the delivery contents.
DN7090562
4 x K30
6 x M5
20 x
2 x
80 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 27. Delivery contents of the RF Module
A.3 Contents of the mounting kit for floor, wall and pole (FMFA) delivery
The FMFA mounting kit is an optional item that has to be orderedseparately, when needed.
The plinth delivery contains the following items:
. Mounting kit for floor, wall and pole
. Adapter mechanics (used in wall and pole installations only)
. Spring washers (18 pcs for M5 screws and 8 pcs for M8 screws)
. 2 x fixing plate for the casing
. 12 x M5 screws
. 6 x M8 screws
See the following figure for more information on the delivery contents.
DN7090605
6 x M5
10 x
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 81 (97)
Contents of deliveries
-
Figure 28. Delivery contents of the plinth
A.4 Contents of the pole mounting kit delivery (optional)
The MetroSite 50 BTS pole mounting kit is an optional item that has to beordered separately, when needed.
The figure Contents of the Nokia MetroSite 50 BTS pole mounting kitdelivery below presents the contents of the pole mounting kit delivery.
DN7090632
12 x M5 18 x
6 x M8 8 x
82 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 29. Contents of the Nokia MetroSite 50 BTS pole mounting kit delivery
A.5 Contents of the transmission sub-module deliveries
The transmission sub-module deliveries contain the following items:
FTPB
. FTPB transmission sub-module with 8 x rubber plugs
. 4 x screws
. 1 x FCM-FTM connector card
See the following figure for more information on the delivery contents.
M8x25 boltsM10x120 bolts
Blocks
DN0484483
M10x200 bolts M10x300 bolts Washers
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 83 (97)
Contents of deliveries
-
Figure 30. Delivery contents of the FTPB
FTEB
. FTEB transmission sub-module with 8 x rubber plugs
. 4 x screws
. 1 x FCM-FTM connector card
. 8 x grounding isolators
See the following figure for more information on the delivery contents.
DN70269818
4 x M5
FCM-FTMconnection card
84 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 31. Delivery contents of the FTEB
FTFA
. FTFA transmission sub-module with 2 x rubber caps
. 4 x screws
. 1 x FCM-FTM connector card
See the following figure for more information on the delivery contents.
DN70269872
4 x M5
FCM-FTMconnection card
8 x groundingisolators
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 85 (97)
Contents of deliveries
-
Figure 32. Delivery contents of the FTFA
FTIA
. FTIA transmission sub-module with 7 x rubber plugs
. 4 x screws
. 1 x FCM-FTM connector card
See the following figure for more information on the delivery contents.
DN70269857
4 x M5
FCM-FTMconnection card
86 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Figure 33. Delivery contents of the FTIA
FTOA
. FTOA transmission sub-module with 1 x rubber plug
. 4 x screws
. 1 x FCM-FTM connector card
. 1 x SDH SFP transceiver
See the following figure for more information on the delivery contents.
DN70269845
4 x M5
FCM-FTMconnection card
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 87 (97)
Contents of deliveries
-
Figure 34. Delivery contents of the FTOA
FTJA
. FTJA transmission sub-module with 7 x rubber plugs
. 1 x FCM-FTM connector card
. 4 x isolators
See the following figure for more information on the delivery contents.
DN70269821
4 x M5
FCM-FTMconnection card
SFP
DN70328061
4 x M5
FCM-FTMconnection card
88 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
A.6 Contents of the transmission cable deliveries
The transmission cable deliveries (FTCx) contain the following items:
Table 3. FTCA/FTCB transmission cable deliveries (used with the FTPB andFTIA)
Cable type Product code Description
FTCA OD CABLE RJ48C -TQ-M/0 120ohm 5 m (16.4ft)
470312A RJ48C to TQ, 1xE1, for co-siting
FTCB OD CABLE RJ48C120ohm 15 m (49.2 ft)
470309A One open end, 1xE1
Table 4. FTCD/FTCE transmission cable deliveries (used with the FTEB andFTJA
Cable type Product code Description
FTCD OD CABLE SMB-F/0 -BT43-F/0 75ohm 5 m(16.4 ft)
470313A SMB to BT43, 1xE1 coax,for co-siting
FTCE OD CABLE SMB-F/0 75ohm 15 m (49.2 ft)
470310A One open end, 1xE1 coax
Table 5. FTCH transmission cable delivery (used with the FTOA)
Cable type Product code Description
FTCH OD CABLE LC SM1310 15 m (49.2 ft)
470311A LC to LC fiber
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 89 (97)
Contents of deliveries
-
Table 6. FTCJ transmission cable delivery (used with the FTFA)
Cable type Product code Description
FTCJ OD cable TNC-F7O-TNC M7O 50 ohm 2.5 m(8.2 ft)
470311A 1 per each FTFA Flexbusinterface
Table 7. FTCR transmission cable delivery (used with the FTIA and FTJA)
Cable type Product code Description
FTCR OD CABLE RJ45CAT5E 15 m (49.2 ft)
471408A One open end, 1xEthernet
90 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Appendix B Installation tools and torque values
B.1 BTS installation tools and equipment
This section lists the installation tools and equipment.
Table 8. Tools for installation
Installation tools
Allen key: 8 mm (0.31 in.)ESD wrist strap and cable
TORX screwdriver set: T10, T20, T25
Screwdriver set: Phillips 0 , 1, 2 and flathead
Wrench 13 mm (0.51 in.)Folding knife
Monkey wrench
Side cutters
Crimping tool for 16 mm grounding cableTorque wrench for antenna cables
Lint-free swab or wipe and 99% alcohol for cleaning optical connectors
Cable ties for routing cables
Tape measure
Flashlight, pocket lamp or torch
Hammer drill
Marker pen or comparable tool
Pliers
B.2 Torque values
Nokia Siemens Networks strongly recommends that you tighten to thefollowing torque values. These values assume the use of a lubricated boltor fastener. Use these values unless stated otherwise.
The torque wrench is presented in the following figure.
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 91 (97)
Installation tools and torque values
-
Figure 35. Torque wrench
Table 9. Torque values for the BTS
Bolt/Screw Type DIN Size Torque
TORX head screwcylinder head
7985 F1-60 M3 0.7 - 1.0 Nm
(0.5 - 0.7 ft-lb)TORX head screwcylinder head
7985 F1-60 M4 1.2 - 1.6 Nm
(0.9 - 1.2 ft-lb)TORX head screwcylinder head
7985 F1-60 M5 2.0 - 2.5 Nm
(1.5 - 1.8 ft-lb)TORX head screwcylinder head
7985 F1-60 M8 10.0 Nm
(7.4 ft-lb)Hexagon head screw(cabinet fixing)
933-12-70 M12 49.0 Nm
(36.1 ft-lb)Allen screw 912-A2-70 M8 8.0 - 10.0 Nm
(5.9 - 7.4 ft-lb)Nut 934 A2 M5 3.7 Nm
(2.7 ft-lb)Nut (cabinet fixing) 934 A2 M12 49 Nm
(36.1 ft-lb)Knurled-head screw(finger tightening)
-NA- M5 approx. 1 Nm(0.7 ft-lb)
Fan fixing screws,plastic
-NA- M4 0.7 Nm
(0.5 ft-lb)
DN70234447
92 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Table 9. Torque values for the BTS (cont.)
Bolt/Screw Type DIN Size Torque
Fan fixing screws,metal
-NA- M4 1.2 Nm
(0.9 ft-lb)
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 93 (97)
Installation tools and torque values
-
Appendix C FTOA optical interface (SFP) requirements
C.1 FTOA optical interface (SFP) requirements
94 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
Table10
.FT
OAop
tical
interfa
ce(SFP
)req
uiremen
ts
Unit
Values
Digitalsigna
lNo
minal
bitrate
kbit/s
STM-1
accordingto
Recommen
dationG.707
15552
0
Applica
tioncode
I-1S-1.1
S-1.2
L-1.1
L-1.2
L-1.3
Ope
ratingwavelen
gth
rang
enm
1260
1)-13
6012
611)-
1360
1430
-157
614
30-158
012
631)-13
6014
80-
1580
1534
-156
6/15
23-157
7
1480
-158
0
Tran
smitter
atreference
pointS
Source
type
MLM
LED
MLM
MLM
SLM
MLM
SLM
SLM
MLM
SLM
Spectra
lcha
racteristics
:
-max.RM
Swidth
()nm
4080
7.7
2.5
-3
--
3/2.5
-
-max.-20
dBwidth
nm
--
--
1-
11
-1
-min.s
idemod
esupp
ressionratio
dB-
--
-30
-30
30-
30
Mea
nlaun
ched
powe
r:
-maximum
dBm
-8
-8
-8
00
0
-minimum
dBm
-15
-15
-15
-5
-5
-5
Min.e
xtinctionratio
dB8.2
8.2
8.2
1010
10
Optica
lpathbe
twee
nS
andR
Attenu
ationrang
edB
0-7
0-12
0-12
10-28
10-28
10-28
Max.d
ispersio
nps/nm
1825
9629
6NA
246
NANA
246/29
6NA
Min.o
ptica
lreturnloss
ofcableplan
tatS
,inclu
ding
any
conn
ectors
dBNA
NANA
NA20
NA
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 95 (97)
FTOA optical interface (SFP) requirements
-
Table10
.FT
OAop
tical
interfa
ce(SFP
)req
uiremen
ts(co
nt.)
Max.d
iscrete
reflectan
cebe
twee
nS
andR
dBNA
NANA
NA-25
NA
Receive
ratreferen
cepo
intR
Min.s
ensitivity
dBm
-23
-28
-28
-34
-34
-34
Min.o
verlo
addB
m-8
-8
-8
-10
-10
-10
Max.o
ptica
lpath
pena
ltydB
11
11
11
Max.reflectan
ceof
receive
r,mea
suredat
R
dBNA
NANA
NA-25
NA
1)So
meAd
ministrations
may
requ
irealim
itof
1270
nm.
96 (97) # Nokia Siemens Networks DN70305645Issue 2-0 en17/10/2007
Installing Flexi WCDMA BTS Modules for Stack, Wall, and PoleConfigurations
-
DN70305645Issue 2-0 en17/10/2007
# Nokia Siemens Networks 97 (97)
FTOA optical interface (SFP) requirements
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole ConfigurationsContents1 Summary of changes in Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole Configurations2 Handling the modules and unpacking the delivery3 Installing Nokia Flexi WCDMA BTS stand-alone4 Preparing the modules for a stand-alone installation5 Lifting the stand-alone BTS6 Grounding principle of the stand-alone BTS7 Installing the stand-alone BTS on the floor7.1 Anchoring the plinth on the floor7.2 Installing modules on the floor
8 Fixing adapter mechanics to plinth9 Mounting the stand-alone BTS on the wall9.1 Mounting the plinth on a wall9.2 Mounting modules on a wall
10 Mounting the stand-alone BTS on the pole10.1 Mounting the plinth on a pole10.2 Mounting modules on a pole
11 Installing transmission sub-module12 Installing Remote Radio Head12.1 Installing Remote Radio Head to a pole12.2 Installing Remote Radio Head to a wall
13 Checklist for installing modulesAppendix A Contents of deliveriesA.1 Contents of the System Module deliveryA.2 Contents of the RF Module deliveryA.3 Contents of the mounting kit for floor, wall and pole (FMFA) deliveryA.4 Contents of the pole mounting kit delivery (optional)A.5 Contents of the transmission sub-module deliveriesA.6 Contents of the transmission cable deliveries
Appendix B Installation tools and torque valuesB.1 BTS installation tools and equipmentB.2 Torque values
Appendix C FTOA optical interface (SFP) requirementsC.1 FTOA optical interface (SFP) requirements