dmn fst manual sp-ec-rot-mt reset module en 20100713-ms

Upload: adrianpashnic

Post on 29-Oct-2015

48 views

Category:

Documents


0 download

DESCRIPTION

reset dongle manual for dryers with multitronic controller

TRANSCRIPT

  • Operating ManualReset Module SP-ECHfor dryers with Multitronic

    Version: 03-DE

    SP-ECH-ROT/MT reset module

    Dear Customer,

    This operating manual contains information that is v

    Proper operation can only be guaranteed if the instructions and notes are observed.

    For your safety

    All the work on the controller must only be carried out by qualified experts or instructed persons!

    Risk of injury from electric voltage

    The controller is connected to voltage, i.e.

    by authorised personnel.

    ATTENTION: The electric supply line is still live!

    Do not touch live parts!

    Operating Manual ECH-ROT/MT

    ith Multitronic controller

    Author: M. Schulte

    ROT/MT reset module for ZANDER MULTITRONIC control

    This operating manual contains information that is valid for reset-module usage.

    Proper operation can only be guaranteed if the instructions and notes are observed.

    must only be carried out by qualified experts or instructed persons!

    Risk of injury from electric voltage

    is connected to voltage, i.e. it is live, and must only be opened and maintained

    by authorised personnel.

    ATTENTION: The electric supply line is still live!

    Do not touch live parts!

    1

    Date: 13.07.2010

    for ZANDER MULTITRONIC controller

    Proper operation can only be guaranteed if the instructions and notes are observed.

    must only be carried out by qualified experts or instructed persons!

    live, and must only be opened and maintained

  • 2

    Intended use of the reset module The reset module is only used for resetting the service messages of the MULTITRONIC controller shown

    above. The module or the controller must never be technically modified. Any modifications may affect the

    operational safety and might lead to damages.

    FST GmbH accepts no liability resulting from improper handling or technical modifications.

    Function description and application

    Function The "SEr." service message is indicated on the display of the MULTITRONIC control system every 8000 *)

    operating hours. The message is flashing and alternates with the standard indication at intervals of 1 minute. *) Depending on the system (e.g. systems for breathing air treatment) the service interval setting may be shorter.

    Using this reset module and following successful maintenance the service monitor is reset to "0". The "SEr."

    message then only appears again after another 8000 operating hours.

    The reset module can only be used once and will then render unusable.

    Application Please proceed exactly as described in the following:

    1. Switch off the MULTITRONIC controller via the main circuit breaker on the left.

    2. Loosen the 4 Phillips head screws and remove the MULTITRONIC front cover.

    Note: To facilitate service work the cover can be screwed in the two upper housing holes using the

    two lower screws. This fixes the cover and therefore the cover does not obstruct the user.

    3. Connect the reset module to the serial port.

    4. Switch on the MULTITRONIC controller.

    5. After a short time the LED on the reset module lights up*. This

    completes the reset procedure. As soon as the LED on the module

    starts flashing the code has been read and the module cannot be

    used again.

    6. To protect the controller, switch it off again and remove the reset

    module.

    7. Reinstall the front cover and restart the MULTITRONIC controller.

    8. Note: The reset module can reset the service timer at any time,

    even if the "SEr." message do not (or not yet) appear.

    Storage Store the reset module in a dry and dust-free environment. It must not be subject to strong magnetic fields,

    temperatures > 50C or intensive sunlight.

    Disposal Waste code: According to the European Waste Catalogue the reset module belongs to "components re-

    moved from discarded equipment", waste code no. 160216.

    Filtrations- und Separationstechnik GmbH, Im Teelbruch 106, D - 45219 Essen, Tel.: +49 (0)2054 8735 -0

    www.fstweb.de

    picture: serial port