Philadelphia Scientific LLC. 207 Progress Drive Montgomeryville, PA 18936 P: 215.616.0390 F: 215.616.0500 www.phlsci.com PAK063 Rev 3/2016 © 2016 Philadelphia Scientific LLC. All Rights Reserved. Philadelphia Scientific and the PS logo are registered trademarks of Philadelphia Scientific LLC. Water Injector System and Instant Valve PRO are trademarks of Philadelphia Scientific LLC. E&O.E. DirectFill (Part Number INJ-DF) Direct Fill Assembly for Philadelphia Scientific ® Water Injector Systems

Upload: others

Post on 28-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DirectFill - phlsci.comPhiladelphiaScientificLLC. 207ProgressDrive Montgomeryville,PA18936 P:215.616.0390 F:215.616.0500  PAK063 Rev 3 /201 6 ©201 6 PhiladelphiaScientificLLC

PhiladelphiaScientificLLC.207ProgressDriveMontgomeryville,PA18936P:215.616.0390F:215.616.0500www.phlsci.com

PAK063Rev 3/2016

©2016PhiladelphiaScientificLLC.AllRightsReserved.PhiladelphiaScientificandthePSlogoareregisteredtrademarksofPhiladelphiaScientificLLC.WaterInjectorSystemandInstantValvePROaretrademarksofPhiladelphiaScientificLLC.E&O.E.

DirectFill(PartNumberINJ-DF)DirectFillAssembly

forPhiladelphiaScientific®WaterInjectorSystems™

PAK063:INJ-DFInstructions11/27/201312:02PMPage1

Page 2: DirectFill - phlsci.comPhiladelphiaScientificLLC. 207ProgressDrive Montgomeryville,PA18936 P:215.616.0390 F:215.616.0500  PAK063 Rev 3 /201 6 ©201 6 PhiladelphiaScientificLLC

Do not fill the Direct Fill directly from afaucet.

The static water pressure may notexceed 80 PSI (25 bar).

ABall Valve with a 3/4” NPTmale threadedfitting must be plumbed in to a pressurizedwater line (>3/4” or more in diameter).

Not included

Attach the black sediment filter to theoutlet of the Ball Valve.

Attach the red hose to the white maleend of the sediment filter. Do not usemore than 20 ft. of hose

Attach the Pressure Regulator to theend of the red hose.

Attach the Instant Valve Pro™ to theend of the Pressure Regulator

Mount included brackets on the wall.

Turn water source on at the ball valve. Connect the Instant Valve Pro™ to theInput Assembly of the Water InjectorSystemÊ installed on the battery.

Squeeze the lever completely to fill thebattery. Do Not Partially Squeeze theLever.

Watch the spinner mounted on theInstant Valve Pro. When it stopsspinning, the filling is completed.

Release the lever and then disconnectthe Instant Valve Pro from the WaterInjector System.

Move on to the next battery. Whenfinished watering batteries, turn thewater off at the ball valve.

Operation:

PAK063:INJ-DF Instructions 11/27/2013 12:02 PM Page 2

Installation:The Philadelphia Scientific Water Injector System requires a water flow ofapproximately 8-10 gallons per minute at 25-35 psi or more. This can bequalified with a Flow Checker (INJ-FC). If your water supply does not meetthese requirements, you will need to purchase an alternative to the Direct Fill.