lPart No: AE-MAN-DEPTH Doc V: 1.0Digital Depth Gauges
•Beforeusingthedepthgaugeforthefirsttime,wipewithacleanclothideallysoakedwithcleaningoil.•Thedepthgaugeisaprecisionmeasuringinstrument.Avoidusingexcessiveforce,andtreatwithcare.•Thefittedbatteryisintendedforthefactorytestprocedureandthereforemaynotmeetthespecifiedbatterylife.•Avoidexposuretoallliquids,excessivehumidityortemperature.•Avoidexposuretobrightsunlight.•Neverapplyvoltageonanypartofthisdepthgaugeorelectricengrave.•Removethebatteryifthegaugeisnotbeingusedforalongperiodoftime.•Neverusesolventstoclean.Onlyuseasoftclothwithcleaningoil.
Precautions
Digital Depth Gauge
Standard Depth GaugeDepth Measurement
Depth
1 3
4
8
5
7 610
9
2
1
2 3
4 5 6
7
8
1. Frame. 2. Anvil. 3. Spindle. 4. LCD Display.5. Thimble. 6.Ratchet. 7. SPC Output.8. Function Buttons.
1
2
3
4
5
7
8
9
10
1. Probe Extension. 2. Function Buttons. 3. LCD Display.4. Slider. 5. Battery Cover. 6. Locking Screw.7. Guiding Face. 8. Beam. 9. Instrument Base.10. Instrument Base Reference Plane.
6
Battery Replacement
1. Slide open the battery cover.
8. Insert the two lugs on the cover.9. Gently lower battery cover.
2. Lift battery cover front edge.3. Remove cover.
4. Remove battery (a magnet tip tool can be used).5. Locate side spring contact.
6. Insert replacement battery edge against side contact. 7. Press down on other edge.
1 2
3
4
5
6
7
8
9
10
11 12
1 2
3
4
5
6
7
8
9
10
11 12
1 2
3
4
5
6
7
8
9
10
11 12
1 2
3
4
5
6
7
8
9
10
11 12
1 2
3
4
5
6
7
8
9
10
11 12
10. Pull battery cover outward sightly11. Fully lower cover
1 2
3
4
5
6
7
8
9
10
11 12
12. Slide battery cover fully closed.
1 2
3
4
5
6
7
8
9
10
11 12
Magnet tipped
tool
Positive (+) side up
8
6
2 4 3
5
7
1
9
1. Base. 2. Reading Head.3.LockingScrew.4.LCDdisplay.5. Data Port.
8
6
2 4 3
5
7
1
9
Depth gauge with hook 6.Beam.7.BatteryCover.8.FunctionButtons.9.Hook.
Depth Gauge with Hook Depth Measurement
(add hook thickness to display value)
Depth Gauge with Hook Thickness Measurement
Depth Gauge with Hook Step Measurement
(add hook thickness to display value)
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group
mac
hine
-dro
.co.
uk
www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.
Dig
ital
Dep
th G
auge
Use
r M
anua
lTrouble Shooting
Metric/Inch conversion
25.40mm
mm/inch
Pressmm/inchtoconvertfrommetrictoinchdisplay.
1.000
Thedisplaywillindicatewhichunitsarebeingdisplayed.
mm/inch
in
Problem PossibleCause SolutionFlashingdisplay Lowvoltage
PoorcontactReplace batteryClean contact
Nodisplay DeadorweakbatteryPoorcontact
Replace batteryClean contact
Nochangetodisplay Internalerror"H"shownondisplay
Remove battery for 1 hourRemove battery for 5 minutes
Can't zero HoldfunctionactiveTolerancefunctionactive
Switch off function Switch off function
Erraticorfrozendisplay Contaminationbetweenbeam&headlowvoltage
Wipe cleanReplace battery
Erroneous reading LowvoltageContaminationbetweenbeam&headLowambienttemperature
Replace battery Wipe cleanStore at normal room temperature
Calibrating Standard Depth Gauge
Calibrating Depth Gauge with hook
1. Ensure the locking screw is loose.2. Wipe clean surface plate or similar flat service.3. Ensure gauge base is clean.4. Place gauge base on surface plate.5. Slide the beam downwards so measuring contact is in contact with the surface plate.6. Press zero button.
1. Ensure the locking screw is loose.2. Ensure gauge base and hook is clean.3. Close the gauge.4. Press zero button.