development application - city of clarence · 2019-10-17 · development application...

8
DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT: Pinnacle Drafting & Design PROPOSAL: Dwelling LOCATION: 145 Canopus Road, MOUNT RUMNEY RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015 ADVERTISING EXPIRY DATE: 5 November 2019 In addition to the Application Form(s), Certificate of Title(s) and any associated consent documents the following information is available on request: Bushfire Hazard Report, 10 October 2019 Bushfire Hazard Management Plan, 10 October 2019 The relevant plans and documents can be inspected at the Council offices, 38 Bligh Street, Rosny Park, during normal office hours until 5 November 2019. Any person may make representations about the application to the General Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to [email protected]. Representations must be received by Council on or before 5 November 2019. To enable Council to contact you if necessary, would you please also include a day time contact number in any correspondence you may forward. Any personal information submitted is covered by Council’s privacy policy, available at www.ccc.tas.gov.au or at the Council offices.

Upload: others

Post on 05-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

DEVELOPMENT APPLICATIONPDPLANPMTD-2019/003911

APPLICANT: Pinnacle Drafting & Design

PROPOSAL: Dwelling

LOCATION: 145 Canopus Road, MOUNT RUMNEY

RELEVANT PLANNING SCHEME: Clarence Interim Planning Scheme 2015

ADVERTISING EXPIRY DATE: 5 November 2019

In addition to the Application Form(s), Certificate of Title(s) and any associated consent documents the following information is available on request:

Bushfire Hazard Report, 10 October 2019 Bushfire Hazard Management Plan, 10 October 2019

The relevant plans and documents can be inspected at the Council offices, 38 Bligh Street, Rosny Park, during normal office hours until 5 November 2019.

Any person may make representations about the application to the General Manager, by writing to PO Box 96, Rosny Park, 7018 or by electronic mail to [email protected]. Representations must be received by Council on or before 5 November 2019.

To enable Council to contact you if necessary, would you please also include a day time contact number in any correspondence you may forward.

Any personal information submitted is covered by Council’s privacy policy, available at www.ccc.tas.gov.au or at the Council offices.

Page 2: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

Drawing No:DA.01DA.02DA.03DA.04DA.05DA.06

DescriptionSite PlanPartial Site PlanFloor PlanElevationsElevationsElevations - Projected

145 Canopus Road, Mt. Rumney 7170

General Information

Jason Nickerson CC6073Y

Owner(s) or Clients Brandt Campbell

Building Classification 1a

Title Reference 160744/2

Design Wind Speed N3

Soil Classification CLASS S

Climate Zone 7

BAL 29

Corrosion Environment Moderate

Zoning Rural Living

Designer

Page 3: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

0 1 2 3 4 5 6 7 8 9

Site Plan

This drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.01

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4218 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:1000 @ A3

19/09/2019 Siting Amendments

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

Bushfire+Changes01/10/2019

33°56

'20" 6

4 .19

213°4

5 '20"

67.97

247.5

252252

250.5

251.5

251

251.5

250.5

251

249.5

250

249

248.5

248

240

242

248.5

250

249.5

247

249

244

245.5

246.524

6

244.5

245

243

243.5

242.5

248

241

241.5

240.5

239.5

239

247.5

247

246

246.5

245.5

206°0

7'10"

143.8

5

245

244.5

244

243.5243

242.5

241.5

242

241240.5

239

240239.5

238.5

237.5237236.5

238.5

238

237.5

237

236.5

236

236

EXIS

TIN

G B

UIL

DIN

GEN

VELO

PE

PRO

POSE

D B

UIL

DIN

G

ENVE

LOPE

POW

ER P

OLE

GR

AVEL

D

RIV

E

SPIK

E IN

GR

AVEL

MT WELL

INGTO

N

TOE

OF

FILL TO

P O

F FI

LL

ston

e on

rock

TOP

OF

BAN

K

TOE

OF

BAN

K

ROOFING

238

313°26 '20 " 192 .2

14527,265m2

CT: 160744/2

PAR

TIAL

SIT

E PL

AN A

REA

C A N

O P U

S

R O A

D

W

HOBART INTERNATIONAL

AIRPORT

N

Site AreasSite area 27,265 sqm

Total Building Area 216.42 sqmTotal Site Coverage 0.79%

Site subject to:

Bushfire Prone Areas Overlay

Landslide Hazard Area Overlay (Medium)

Biodiversity Protection Area Overlay

Page 4: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

Partial Site PlanThis drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.02

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4743 F: 03 6248 4745 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:250

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

19/09/2019 Siting Amendments

Bushfire+Changes01/10/2019

EXISITING GRAVEL

DRIVEWAY303.60 m2

SPIK

E IN

GR

AVEL

Surface irrigationarea 200sqm

Pressure compensating

sprinklers spaced at 5 - 7m

to ensure even coverage.

Check valves to be used.

Stormwater absorption trench14m long x 1.2 wide x 0.45m deep

W T

AWTS

10,000ltrFIRE

FIGHTING TANK

FFL 242,500

RL 242,450

RL 242,450

247 .5

252252

250.5

251 .5

251

251 .5

250.5

2 51

249 .5

250

249

248 .5

248

240

242

248 .5

250

249 .5

247

249

244

245 .5

246 .524

6

244 .5

245

243

243.5

242 .5

248

241

241.5

240.5

239.5

239

247.5

247

246

246 .5

245 .5

206°0

7'10"

143.8

5

245

244 .5

244

243 .5243

242 .5

241 .5

242

241

238

240 .5

239

240239 .5

238 .5

237 .5237236 .5

238.5

238

237.5

237

236 .5

236

236

EXIS

TIN

G B

UIL

DIN

G E

NVE

LOPE

PRO

POSE

D B

UIL

DIN

G E

NVE

LOPE

POW

ER P

OLE

GR

AVEL

D

RIV

E

MT WELL

INGTO

N

TOE

OF

FILL

TOP

OF

FILL

ston

e on

rock

TOP

OF

BAN

KTOE

OF

BAN

K

3 1 3 °2 6 '2 0 " 1 9 2 .2

PROPOSEDPARKING AREA

PROPOSEDEXCAVATED FILL

PROPOSED CUT

PROPOSED CUT

RETAINING WALL

RET

AIN

ING

WAL

L

PROPOSED STAIRFROM PARKING TO

ENTRY

PROPOSEDEXCAVATED FILL

18 RISERS 150H355 DEEP

4 RISERS 150H355 DEEP

PROPOSEDCUT

14527,265m2

CT: 160744/2

AWTSShallowsurface

diversiondrain upslopeof irragation

area

"T" TURNING AREA ANDHARDSTAND AREA FOR

CONNECTION TO WATERSUPPLY CONTAINED WITHING

THIS AREA

FT

WIDENDRIVEWAYWIDTH TO

ACCOMODATEHARDSTAND

W HOSE LAY

FROMENGINE

10,000

11,236

22,028

48,0

10

46,9

53FFL 242,500

PROPOSEDNEW

DWELLING108.80 m2

PROPOSED COMPOSITE

DECK 26.16 m2

PROPOSED COMPOSITEENRTY DECK

30.58 m2

HOBART INTERNATIONAL

AIRPORT

SELE

CTE

D T

IMBE

R

SELECTED TIMBERN

Site AreasSite area 27,265 sqm

Total Building Area 171.03 sqmTotal Site Coverage 0.62%

Page 5: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

Floor PlanThis drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.03

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4743 F: 03 6248 4745 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:100

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

19/09/2019 Siting Amendments

Bushfire+Changes01/10/2019

DW

F OVEN

wm650

108.80 m2

26.16 m2

30.48 m2

BED 2

ENSUITE

W.I.R.

LAUN

DRY

KITCHEN

DINING

ENTRY

LIVING

BULKHEAD 2400 - RAKED

BULKHEAD2400 - RAKED

RAKED CEILING

RAKED CEILING

BATHW.I.R.

BED 1

DECKRE

TAIN

ING

WAL

L - T

O E

NGI

NEE

RS S

PECI

FICA

TIO

NS

RETAINING WALL - TO ENGINEERS SPECIFICATIONS

FREE

STANDIN

G

FIRE P

LACE

OUTDOORBATHROOM

TIMBER SCREEN

PAVEDAREA

18 RISERS 150H 355 D

6 RISERS 150H 355 D

820

720

21-18SD

720820

820

1,200 - 600

OBSC

1,200 - 600

AW

1,200 - 600

AW

2,100 x 2,720

2,400 - 900

FW2,100 - 900

FW

2,100 - 900

AW 2,100 - 900

FW

2,100 - 900

FW 2,100 - 900

AW

2,100 - 900

FW 2,100 - 900

FW

2,100 - 900

AW 2,100 - 900

FW

2,400 x 3,600

2,100 - 900FW

1,200

- 1,5

00AW2,4

00 -

900

FW

2,100

- 90

0FW

2,100

- 90

0AW

2,100

- 90

0FW

2,40

0 x

3,60

02,

100

x 3,

300

2,10

0 x

1,80

0

TIMBER STAIRS & LANDINGS

12,199

15,000

15,0

00

12,1

99

4,000

3,777

902,425

901,900 90

3,800

901,100

8,767

90

5,990

2,01

090

3,50

090

1,95

090

600

1,30

090

01,

641

905,

600

909,

157

7,24

1

5,84

0

5,8407,241

90 1,120 2,100 600 90

90 1,00090

700 90 1,940

3,820 90 1,000

1,820 2,000

189

1,00090

2,730

901,000

90

3,820

190

4,000

2,090

2,000

FFL 242,500

RL 242,450

RL 242,450

110.00°

CARPET

TILES

CARPET

CARPET

CARPET

CARPET

CARPET

TILESCARPET

CARPET

COMPOSITEDECKING

CH:2400

CH:2400

CH:2400

CH:RAKED

CH:RAKED

CH:RAKED

CH:RAKED

CH:2400CH:2400

CH:2400

UP

ENTRYDECK

COMPOSITEDECKING

N

Floor AreasGround Floor 108.80 sqm

Entry Stairs 23.61 sqmEntry Deck 36.07 sqm

Total 108.80 sqm

26.16 sqmDeck

Page 6: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

0 1 2 3 4 5 6 7 8 9

Elevations

This drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.04

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4218 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:100 @ A3

19/09/2019 Siting Amendments

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

Bushfire+Changes01/10/2019

FFL:242,500

650

150

min

2,40

0

150

min

Excavated fill to be placed in this area- filled after footings and postscomplete to min 150mm belowwcladding

Custom orb colorbondroof pitched @ 5° -Colorbond Monument

Steel framedcomposite timberdeck

SHS posts

Retaining wall toEngineersspecifications

Concrete pad footings to Engineersspecifications

Colorbond claddinghorzontal layout -Colorbond Monument Matt

Glass balustrades to comply withNCC 3.9.2, not less than 1mabove FFL

Excavated fill to be placed in this area- filled after footings and postscomplete to min 150mm belowwcladding

Steel framedcomposite landing

to deck 5 x 2.4

Outdoor Bathroom

CEILING

MGL

NGL

FFL:242,500

Min

150

650

2,40

0

O/A

5

,286

Excavated fill to be placed in this area- filled after footings and postscomplete to min 150mm belowwcladding

Custom orb colorbondroof pitched @ 5° -Colorbond Monument

Steel framedcomposite timberdeck

SHS posts

Retaining wall to Engineersspecifications

Concrete pad footings to Engineersspecifications

Colorbond claddinghorzontal layout -Colorbond Monument

Glass balustrades to comply withNCC 3.9.2, not less than 1mabove FFL

Excavated fill to be placed in this area- filled after footings and posts

complete to min 150mm belowwcladding

CEILING

MGL

NGL

NGL

MGL

North Elevation

North West Elevation

Page 7: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

0 1 2 3 4 5 6 7 8 9

Elevations

This drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.05

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4218 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:100 @ A3

19/09/2019 Siting Amendments

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

Bushfire+Changes01/10/2019

FFL:242,500

Min

150

650

2,40

0

Custom orb colorbondroof pitched @ 5° -Colorbond Monument

SHS posts

Retaining wall toEngineersspecifications

Colorbond cladding horzontal layout- Colorbond Monument Matt

Glass balustrades to comply withNCC 3.9.2, not less than 1m

above FFL

Excavated fill to be placed in this area- filled after footings and postscomplete to min 150mm belowwcladding

Steel framedcomposite timber

deck

CEILING

MGL

NGL

NGL

FFL:242,500

650

2,40

0

Steel framedcomposite timberdeck

SHS postsRetaining wall to

Engineersspecifications

Colorbond claddinghorzontal layout -

Colorbond Monument Matt

Glass balustrades to comply withNCC 3.9.2, not less than 1mabove FFL

Excavated fill to be placed in this area- filled after footings and posts

complete to min 150mm belowwcladding

Fill supporting paving and associatedplumbing for outdoor bathroom

Custom orb colorbondroof pitched @ 5° -

Colorbond Monument

Timber framed /clad screen wall

Cantilevered roofpitched at 1°

Timber framed /clad screen wall

CEILING

MGL

NGL

NGL

cut

South West Elevation

East Elevation

Page 8: DEVELOPMENT APPLICATION - City of Clarence · 2019-10-17 · DEVELOPMENT APPLICATION PDPLANPMTD-2019/003911 APPLICANT:Pinnacle Drafting & Design PROPOSAL:Dwelling LOCATION:145 Canopus

GSPublisherVersion 0.0.100.100

0 1 2 3 4 5 6 7 8 9

Elevations - Projected

This drawing is the property of Pinnacle Drafting & Design, reproduction in whole or part is strictly forbidden without written consent. © 2019

Address:Client:Proposal:

Date: 06/06/2019Drawn: Steve

Job No: 068-2019Engineer:Building Surveyor:

Pg No: DA.06

PINNACLE DRAFTING & DESIGN. CC6073Y 2 Kennedy Drv, Cambridge 7170 P: 03 6248 4218 E: [email protected]

145 Canopus Road, Mt. Rumney 7170

Brandt CampbellNew Dwelling Scale: 1:100 @ A3

19/09/2019 Siting Amendments

AmendmentsDate Description

NOT

FOR

CONS

TRUC

TIO

N

Bushfire+Changes01/10/2019

FFL:242,500

650

2,40

0

Excavated fill to be placed in this area- filled after footings and posts

complete to min 150mm belowwcladding

Retaining wall toEngineers

specifications

Custom orb colorbondroof pitched @ 5° -Colorbond Monument

SHS posts supporting roofColorbond claddinghorzontal layout -Colorbond Monument Matt

SHS posts supporting roof

Stair from carparkto entry 150 Rise

355 Run

Timber framed/cladscreen wall

CEILING

NGL

MGL

cut

NGL

FFL:242,500

1,40

0

2,40

0

Custom orb colorbondroof pitched @ 5° -Colorbond Monument

SHS postssupporting roofover walkway

Colorbond claddinghorzontal layout -Colorbond Monument

Excavated fill to be placed in this area- filled after footings and postscomplete to min 150mm belowwcladding

Retaining wall toEngineers

specifications

Stair from carparkto entry 150 Rise

355 Run

Cut depth behindretaining wall

1400mm from top

Concrete pad footings to Engineersspecifications

Steel framed compositetimber landing Timber

framed/cladscreen wall

Conc. pathto garage

CEILING

MGL

NGL

cutcutMGL

NGL

West North West Elevation

South Elevation