detex low energy automatic door operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422)...

9
104851 January 31, 2013 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)-629-2900 / 1-800-729-3839 / Fax (830)-620-6711 E-MAIL: detex @ detex.com INTERNET: www.detex.com The Detex Low Energy Automatic Door Operator must be installed to comply with the latest revision of ANSI /BHMA A156.19 (American National Standard for Power Assist and Low Energy Power Operated Doors) and upon completion of installation, the owner should have an inspection performed by an AAADM certified inspector. In special applications where safety sensors are used on low energy doors, the sensors and the related adjustments should comply with the criteria set forth in ANSI/BHMA A156.10 (American National Standard for Power Operated Pedestrian Doors). Failure to conform to these requirements may cause operating failures which can result in serious injury or property damage. It is the owner’s responsibility to assure the reliable and safe operation of this device; routine service and inspection should be performed at least annually by an AAADM certified inspector. More frequent service may be required when the operating environment or other conditions dictate or if required by the local authority having jurisdiction. Proper operation should be checked everyday by the owner. Detex Corporation accepts no liability for property damage, warranty claims or personal injury, if this Detex product is not properly installed for compliance to these requirements by a qualified automatic door operator installer and also properly maintained and inspected by the owner to operate as required by ANSI/BHMA A156.19 (or ANSI/BHMA A156.10 where required). DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Pull 104851 Page 1 CAUTION Read this notice before installing or servicing Installer’s Copy

Upload: others

Post on 21-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

104851January31,2013

DetexCorporation,302DetexDrive,NewBraunfels,Texas78130-3045(830)-629-2900/1-800-729-3839/Fax(830)-620-6711

E-MAIL:[email protected] INTERNET:www.detex.com

TheDetexLowEnergyAutomaticDoorOperatormustbeinstalledtocomplywiththelatestrevisionofANSI/BHMAA156.19(AmericanNationalStandardforPowerAssistandLowEnergyPowerOperatedDoors)anduponcompletionofinstallation,theownershouldhaveaninspectionperformedbyanAAADMcertifiedinspector.Inspecialapplicationswheresafetysensorsareusedonlowenergydoors,thesensorsandtherelatedadjustmentsshouldcomplywiththecriteriasetforthinANSI/BHMAA156.10(AmericanNationalStandardforPowerOperatedPedestrianDoors).Failuretoconformtotheserequirementsmaycauseoperatingfailureswhichcanresultinseriousinjuryorpropertydamage.Itistheowner’sresponsibilitytoassurethereliableandsafeoperationofthisdevice;routineserviceandinspectionshouldbeperformedatleastannuallybyanAAADMcertifiedinspector.Morefrequentservicemayberequiredwhentheoperatingenvironmentorotherconditionsdictateorifrequiredbythelocalauthorityhavingjurisdiction.Properoperationshouldbecheckedeverydaybytheowner.DetexCorporationacceptsnoliabilityforpropertydamage,warrantyclaimsorpersonalinjury,ifthisDetexproductisnotproperlyinstalledforcompliancetotheserequirementsbyaqualifiedautomaticdooroperatorinstallerandalsoproperlymaintainedandinspectedbytheownertooperateasrequiredbyANSI/BHMAA156.19(orANSI/BHMAA156.10whererequired).

DETEXLowEnergyAutomaticDoorOperatorAO19-1

SingleDoor-Pull

104851Page1

CAUTIONReadthisnoticebeforeinstallingorservicing

Installer’s Copy

Page 2: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

ToolsRequired

1-Knife 1-3/16”Drillbit 1-WireStripper/Crimper1-Level 1-½“Drillbit 1-Hacksaw1-TapeMeasure 1-3/8”DrillMotor 2-18”BarClamps1-#2Phillips 1-3/8”Drillbit 1-SetAllenWrenches1-#3PhillipsBit 1-Box3/16”x1¼”Tapcons1-SafetyGlasses 1/4-20or#14FlatHeadScrews1-Thinbrush

GeneralConditions

TheDetexLowEnergyAutomaticDoorOperatorisdesignedforResidential,CommercialandIndustrialuse.Ifistoberetrofittedontoanexistingdoorandframe,itisimportantthatthedoorisingoodconditionandswingsfreely,withoutrestriction.Itisalsoimportantthattheheaderissturdyandtheoperatormustbefastenedsecurelyusingtheappropriatefasteners.

WARNING:Toreducetheriskofinjuriestopersons–usethisoperatoronlywitha250lb.door(s)max.

AllelectricalwiringmustcomplywiththeNationalElectricalCode.

NotcompatiblewithGFI(GroundFaultInterrupt)Breaker.

TheDetexLowEnergyAutomaticDoorOperatormustbeinstalledtocomplywithANSI/BHMAA156.19standards.Itisnotasolutiontowindorstackairconditions.Iftheseconditionsexist,pleasecallfactoryforfurtherinformationandpossiblesolutions.

Bewarethatthedoorshould:1)opentoatleast32”ofclearopening;2)have5’x5’offlatflooronbothsides;3)beprotectedatbottomrail,7½”up;4)thresholdmustmeetADAGuidelines;and5)acommercialorresidentialswingingpedestriandoorshallnotclosewithaforcegreaterthan15lb.atthelatchsideoftheclosingstileandshallnotclosethroughthefinal10degreesinlessthan1.5seconds.

104851Page2

Page 3: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

Verifythatthedeviceorderedisthecorrectmodelforthedoorapplication.Inspectpackageforpossibleshippingdamages.Carefullycuttapeandopencardboardshippingbox.Packedintothisboxyouwilltypicallyfindarmassembly,doordecal(s),completelowenergyoperatorandinstructiondocuments.Removeitemsandplacethemcarefullyasidesotheywillnotbedamagedorlost.Usinga#2Phillips,removethecoverscrewsandliftcover.Removepackingandinspectallitemsbeforecontinuing.

Receiving Inspection

Contact Factory on damages and missing equipment

Installation Preparation

ThehangerbracketassemblyisuniquetotheDetexLowEnergyAutomaticDoorOperator.Itallowstheinstallationtobeperformedbyoneperson,quicklyandefficiently.

LocatePhillipsscrewsinsideatthetopcorners.Removethese(screwswillbeusedagain)andseparatetheenclosurefromthehangerplate.

104851Page3

HangerPlateDetexPart#-12515-X

REMOVE THESE TWO SCREWSAND KEEP TO BE USED AGAIN

3-PositionSwitch Assy(105422) UDC 1000

Controller(105421)

LineFilter(105416-2)

GearMotor(104796-X)

Page 4: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

InstallationHanger Plate Location for Single Pull Units

Thehangerplateshouldbelocated5/8"fromtheoutsideedgeofthehingejamb,(typical13/4”frameface)leveland1-1/16”abovebottomofthedoorframe.Thegoalistobeabletopassthedoorunderthemainshaftofthemotor.Barclampthehangerplate.Usinghangerplatemarkanddrillholesintotheheaderframeorsolidwallorwallstud.Fastenusingappropriatetypeandsizescrews(Detexrecommendsusingflatheadtype).Note:Drillingdebrisaccumulatedinhangergroovetrackscanpreventtheoperatorfromseat-inguniformlywhenmounting.Removedebriswiththinbrush.Maskingtapecanalsobeusedtopreventdebrisfromcollectingingroove.

Lifttheoperatorandlowerontothewebsofthehangerplatebracket.Besurebothtopandbottomareengaged.

104851Page4

SECURE HANGER WITH SCREWS

HINGED SIDE

5/8”

1-1/16”

HangerPlate

Oncetheyareseated,pulldownuntilunitiscompletelyflushandscrewscanbereplacedintopcorners.

ReplaceScrewhere

ReplaceScrewhere

Page 5: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

Havealicensedelectricianbring120vACRMStotheDetexLowEnergyAutomaticDoorOperatorinaccordancewithalllocalandstateelectricalcodes.Besurethe120vACRMSpowersupplyisturnedoffbeforeproceeding.The120vACRMSpowerlinecanberunthrutheknockoutholeattheendoftheoperatorcaseandintotheoutletboxprovided.Youshouldinspectallwiringatthistimebeforeturningonpowerandconnectingelectricalcordtooutletconnector.

104851Page5

120 vAC RMS to Controller Module connection

Connection from 120 vAC RMS sourcePerformed by licensed electrician.

120 vAC RMS Connections

Page 6: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

104851Page6

Arm Positioning For Pull Units

ReviewtheInstallationGuideforDetexLowEnergyAutomaticDoorOperatorControlModule,P/N104827beforeproceeding.Wehavepresetcontrolstoapproximatesettings.Openthedoorto90°(degrees).Turnthe3-waytoggleswitch,locatedatendofenclosure,to“HOLD”position.

Theoperatorwillactivateandthemotoroutputshaftwillrotate240°(degrees).Installthearmsotheforearmisrotatedto90°andparalleltodoorleafandsecurebytighteningscrew.Whileinthefullopenposition,applythesafetywashertothebottomofshaft.

Withthedoorandgearmotorinfullopenposition,marktheforearmpinlocationfortheendpointoftravelandthepindepthonthedoor.

Turnthe3-waytoggleswitchto“OFF”position.Attheclosedposition,markthearmpinlocationfortheoppositeendpointoftravelandforpindepth.

Centerthetrackoverthepintravellocations.Settheheightofthetracksothatthepinmaintainsclearancewiththebottomofthetrackthroughouttheentirelengthoftravel.

Markthemountingholesandattachwiththeappropriatefasteners.Openthedoorandswitchthe3-waytoggleswitchtothe“HOLD”position.Installthetrackwiththepinintheslideblock,usethesuppliedscrews(two#14x1-1/4”TEKScrews).

Left-hand pull assembly

Block-P/N-12784

Forearm-P/N-12787-X

PowerArm-P/N-12781-X

Track-P/N-12785-X

Left-hand pull assembly

Page 7: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

104851Page7

Low Voltage Activation Connections

You must disconnect all voltage sources before attempting to install an accessory.

AlongwithyourDetexLowEnergyAutomaticDoorOperator,youreceivedanInstallationGuideforDetexLowEnergyOperatorControlModule,P/N104827.Thisdocumentwillhelpwiththepropersetup,switchoptionsandwiringschematics.TheON/OFF/HOLD3-waytoggleswitchhasbeenpre-wiredintotheControlModuleandislocatedatoneendoftheenclosure.

Beforeanyadjustmentscanbemadethefollowingcheckmustbeperformed.Firstthearmmustbeproperlyconnectedtothedoorleaf.ThepowermustbeconnectedandtheswitchintheONposition.Thedoorleafmustbefullyclosed.ExaminetheDoorControl.Thecontrolboardmusthavethreelightsilluminated.LATCH,POWER,andMODULEON.IftheCLOSElightison,reviewthearmassemblylocationbymanuallyopeningdoorleafuntilitisstoppedbyinternalstop.Ifthedoorarmrotateswellbeyond80degreesreferbacktoarminstallationdirections.Ifarmstopsatapproximately80degrees,allowtheleaftoclose.

TheLATCH-CHECKandBACK-CHECKSarecontrolledviathecamontopofthegearbox.Accessisthruthetopoftheoperatorcasedirectlyabovethegearbox.Usinga1/8thinchAllenwrench,gentlyloosenthescrewthatholdsthecaminplace.RotatecamintheclosingrotationdirectionuntiltheCLOSElightgoesoutandtheLATCHlightcomeson.Holdingthecaminplacegentlyretightentheholdingscrew.

DONOTOVERTIGHTENASTHATWILLDAMAGETHECAM.

TesttheLATCH-CHECKpositionbymanuallyopeningthedoorleafuntilyouseeLATCH-CHECKlightgooutandtheCLOSElightcomeson.Thisshouldbeapproximately4inchesfromJamb.Finetuneadjustmentasnecessary.Ifthelightsfailtoworkcallforfactoryassistance.

THE DETEX, LOW ENERGY AUTOMATIC DOOR OPERATOR, IS TO BE USED WITH APPROVED SWITCHES.

ContactfactoryforinformationonSensorconnections.

Typicallyyouwilluseawallmounted,hardwiredpushbuttonforactivation.YoumustprovidewirefromthepushbuttonswitchtotheControlModuleinputs.Knockoutsareavailableontheenclosureforwireruns.Theconnectionsareterminatedonterminals#1and#2oftheControlModule.RefertothediagramincludedwiththeControlModule.

BE SURE ALL WIRING MEETS ALL STATE AND LOCAL CODES.

Page 8: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

104851Page8

Button Location

Locatethebuttonssecurelytoawallorpost.Besurethebuttonisnotblockedbyopeneddoororcausetheusertobeinthepathofthedoorleafwhenopening.Checklocalcodesforvariationsinlocationrequirements.

Anotherpopulartypeofbuttonhasbattery-operatedtransmitters.Theyworkwithareceivermountedinoperatorcase.ThereceivermaybeconnectedtotheControlModuleforasourceofpower.Connectpowerwiresto#12and#13forA.C.,or#1and#11forD.C.Connectthe“COM”and“N.O.”outputstoterminals#1and#2ofthecontrolmodule.

Eachtransmittersettingmustbeprogrammedtothesamesettingofthereceivertooperatecorrectly.

PerANSI/BHMAA156.19,switchistobeinstalledwithinviewofdooratamaximumdistanceof144”(3658mm)fromthecenterofthedoorandmountedaminimumof36”(914mm)andamaximum48”(1219mm)fromthefinishedfloor.

Page 9: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation

104851Page9

Decal Application

You’vebeenprovidedwithadouble-sidedecalthatmeetsANSI/BHMAA156.19,asfollows:Adoorshallbemarkedwithadecal,visiblefromtheswingside,withthewords

“AUTOMATIC CAUTION DOOR”

Thesignshallbemountedondoorataheight58in.+/-5in.fromthefloortocenterlineofthesign.Thesignshallbeaminimumof6in.indiameterwithblackletteringonayellowbackground.

Final Inspection

Beforeleavingsite,testallactivationdevicesandtimeyourdoor.Toreducecall-backs,instructowneronthelegaloperationofdoor,howtoturnonandoff,functionandwarrantyconsiderations.

This operator must be installed/serviced by a qualified person. The service technician must be familiar with the latest

ANSI/BHMA A156.10/19 standards.

Call factory for technical support800-729-3839

Decal(104787)