![Page 1: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/1.jpg)
104851January31,2013
DetexCorporation,302DetexDrive,NewBraunfels,Texas78130-3045(830)-629-2900/1-800-729-3839/Fax(830)-620-6711
E-MAIL:[email protected] INTERNET:www.detex.com
TheDetexLowEnergyAutomaticDoorOperatormustbeinstalledtocomplywiththelatestrevisionofANSI/BHMAA156.19(AmericanNationalStandardforPowerAssistandLowEnergyPowerOperatedDoors)anduponcompletionofinstallation,theownershouldhaveaninspectionperformedbyanAAADMcertifiedinspector.Inspecialapplicationswheresafetysensorsareusedonlowenergydoors,thesensorsandtherelatedadjustmentsshouldcomplywiththecriteriasetforthinANSI/BHMAA156.10(AmericanNationalStandardforPowerOperatedPedestrianDoors).Failuretoconformtotheserequirementsmaycauseoperatingfailureswhichcanresultinseriousinjuryorpropertydamage.Itistheowner’sresponsibilitytoassurethereliableandsafeoperationofthisdevice;routineserviceandinspectionshouldbeperformedatleastannuallybyanAAADMcertifiedinspector.Morefrequentservicemayberequiredwhentheoperatingenvironmentorotherconditionsdictateorifrequiredbythelocalauthorityhavingjurisdiction.Properoperationshouldbecheckedeverydaybytheowner.DetexCorporationacceptsnoliabilityforpropertydamage,warrantyclaimsorpersonalinjury,ifthisDetexproductisnotproperlyinstalledforcompliancetotheserequirementsbyaqualifiedautomaticdooroperatorinstallerandalsoproperlymaintainedandinspectedbytheownertooperateasrequiredbyANSI/BHMAA156.19(orANSI/BHMAA156.10whererequired).
DETEXLowEnergyAutomaticDoorOperatorAO19-1
SingleDoor-Pull
104851Page1
CAUTIONReadthisnoticebeforeinstallingorservicing
Installer’s Copy
![Page 2: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/2.jpg)
ToolsRequired
1-Knife 1-3/16”Drillbit 1-WireStripper/Crimper1-Level 1-½“Drillbit 1-Hacksaw1-TapeMeasure 1-3/8”DrillMotor 2-18”BarClamps1-#2Phillips 1-3/8”Drillbit 1-SetAllenWrenches1-#3PhillipsBit 1-Box3/16”x1¼”Tapcons1-SafetyGlasses 1/4-20or#14FlatHeadScrews1-Thinbrush
GeneralConditions
TheDetexLowEnergyAutomaticDoorOperatorisdesignedforResidential,CommercialandIndustrialuse.Ifistoberetrofittedontoanexistingdoorandframe,itisimportantthatthedoorisingoodconditionandswingsfreely,withoutrestriction.Itisalsoimportantthattheheaderissturdyandtheoperatormustbefastenedsecurelyusingtheappropriatefasteners.
WARNING:Toreducetheriskofinjuriestopersons–usethisoperatoronlywitha250lb.door(s)max.
AllelectricalwiringmustcomplywiththeNationalElectricalCode.
NotcompatiblewithGFI(GroundFaultInterrupt)Breaker.
TheDetexLowEnergyAutomaticDoorOperatormustbeinstalledtocomplywithANSI/BHMAA156.19standards.Itisnotasolutiontowindorstackairconditions.Iftheseconditionsexist,pleasecallfactoryforfurtherinformationandpossiblesolutions.
Bewarethatthedoorshould:1)opentoatleast32”ofclearopening;2)have5’x5’offlatflooronbothsides;3)beprotectedatbottomrail,7½”up;4)thresholdmustmeetADAGuidelines;and5)acommercialorresidentialswingingpedestriandoorshallnotclosewithaforcegreaterthan15lb.atthelatchsideoftheclosingstileandshallnotclosethroughthefinal10degreesinlessthan1.5seconds.
104851Page2
![Page 3: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/3.jpg)
Verifythatthedeviceorderedisthecorrectmodelforthedoorapplication.Inspectpackageforpossibleshippingdamages.Carefullycuttapeandopencardboardshippingbox.Packedintothisboxyouwilltypicallyfindarmassembly,doordecal(s),completelowenergyoperatorandinstructiondocuments.Removeitemsandplacethemcarefullyasidesotheywillnotbedamagedorlost.Usinga#2Phillips,removethecoverscrewsandliftcover.Removepackingandinspectallitemsbeforecontinuing.
Receiving Inspection
Contact Factory on damages and missing equipment
Installation Preparation
ThehangerbracketassemblyisuniquetotheDetexLowEnergyAutomaticDoorOperator.Itallowstheinstallationtobeperformedbyoneperson,quicklyandefficiently.
LocatePhillipsscrewsinsideatthetopcorners.Removethese(screwswillbeusedagain)andseparatetheenclosurefromthehangerplate.
104851Page3
HangerPlateDetexPart#-12515-X
REMOVE THESE TWO SCREWSAND KEEP TO BE USED AGAIN
3-PositionSwitch Assy(105422) UDC 1000
Controller(105421)
LineFilter(105416-2)
GearMotor(104796-X)
![Page 4: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/4.jpg)
InstallationHanger Plate Location for Single Pull Units
Thehangerplateshouldbelocated5/8"fromtheoutsideedgeofthehingejamb,(typical13/4”frameface)leveland1-1/16”abovebottomofthedoorframe.Thegoalistobeabletopassthedoorunderthemainshaftofthemotor.Barclampthehangerplate.Usinghangerplatemarkanddrillholesintotheheaderframeorsolidwallorwallstud.Fastenusingappropriatetypeandsizescrews(Detexrecommendsusingflatheadtype).Note:Drillingdebrisaccumulatedinhangergroovetrackscanpreventtheoperatorfromseat-inguniformlywhenmounting.Removedebriswiththinbrush.Maskingtapecanalsobeusedtopreventdebrisfromcollectingingroove.
Lifttheoperatorandlowerontothewebsofthehangerplatebracket.Besurebothtopandbottomareengaged.
104851Page4
SECURE HANGER WITH SCREWS
HINGED SIDE
5/8”
1-1/16”
HangerPlate
Oncetheyareseated,pulldownuntilunitiscompletelyflushandscrewscanbereplacedintopcorners.
ReplaceScrewhere
ReplaceScrewhere
![Page 5: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/5.jpg)
Havealicensedelectricianbring120vACRMStotheDetexLowEnergyAutomaticDoorOperatorinaccordancewithalllocalandstateelectricalcodes.Besurethe120vACRMSpowersupplyisturnedoffbeforeproceeding.The120vACRMSpowerlinecanberunthrutheknockoutholeattheendoftheoperatorcaseandintotheoutletboxprovided.Youshouldinspectallwiringatthistimebeforeturningonpowerandconnectingelectricalcordtooutletconnector.
104851Page5
120 vAC RMS to Controller Module connection
Connection from 120 vAC RMS sourcePerformed by licensed electrician.
120 vAC RMS Connections
![Page 6: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/6.jpg)
104851Page6
Arm Positioning For Pull Units
ReviewtheInstallationGuideforDetexLowEnergyAutomaticDoorOperatorControlModule,P/N104827beforeproceeding.Wehavepresetcontrolstoapproximatesettings.Openthedoorto90°(degrees).Turnthe3-waytoggleswitch,locatedatendofenclosure,to“HOLD”position.
Theoperatorwillactivateandthemotoroutputshaftwillrotate240°(degrees).Installthearmsotheforearmisrotatedto90°andparalleltodoorleafandsecurebytighteningscrew.Whileinthefullopenposition,applythesafetywashertothebottomofshaft.
Withthedoorandgearmotorinfullopenposition,marktheforearmpinlocationfortheendpointoftravelandthepindepthonthedoor.
Turnthe3-waytoggleswitchto“OFF”position.Attheclosedposition,markthearmpinlocationfortheoppositeendpointoftravelandforpindepth.
Centerthetrackoverthepintravellocations.Settheheightofthetracksothatthepinmaintainsclearancewiththebottomofthetrackthroughouttheentirelengthoftravel.
Markthemountingholesandattachwiththeappropriatefasteners.Openthedoorandswitchthe3-waytoggleswitchtothe“HOLD”position.Installthetrackwiththepinintheslideblock,usethesuppliedscrews(two#14x1-1/4”TEKScrews).
Left-hand pull assembly
Block-P/N-12784
Forearm-P/N-12787-X
PowerArm-P/N-12781-X
Track-P/N-12785-X
Left-hand pull assembly
![Page 7: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/7.jpg)
104851Page7
Low Voltage Activation Connections
You must disconnect all voltage sources before attempting to install an accessory.
AlongwithyourDetexLowEnergyAutomaticDoorOperator,youreceivedanInstallationGuideforDetexLowEnergyOperatorControlModule,P/N104827.Thisdocumentwillhelpwiththepropersetup,switchoptionsandwiringschematics.TheON/OFF/HOLD3-waytoggleswitchhasbeenpre-wiredintotheControlModuleandislocatedatoneendoftheenclosure.
Beforeanyadjustmentscanbemadethefollowingcheckmustbeperformed.Firstthearmmustbeproperlyconnectedtothedoorleaf.ThepowermustbeconnectedandtheswitchintheONposition.Thedoorleafmustbefullyclosed.ExaminetheDoorControl.Thecontrolboardmusthavethreelightsilluminated.LATCH,POWER,andMODULEON.IftheCLOSElightison,reviewthearmassemblylocationbymanuallyopeningdoorleafuntilitisstoppedbyinternalstop.Ifthedoorarmrotateswellbeyond80degreesreferbacktoarminstallationdirections.Ifarmstopsatapproximately80degrees,allowtheleaftoclose.
TheLATCH-CHECKandBACK-CHECKSarecontrolledviathecamontopofthegearbox.Accessisthruthetopoftheoperatorcasedirectlyabovethegearbox.Usinga1/8thinchAllenwrench,gentlyloosenthescrewthatholdsthecaminplace.RotatecamintheclosingrotationdirectionuntiltheCLOSElightgoesoutandtheLATCHlightcomeson.Holdingthecaminplacegentlyretightentheholdingscrew.
DONOTOVERTIGHTENASTHATWILLDAMAGETHECAM.
TesttheLATCH-CHECKpositionbymanuallyopeningthedoorleafuntilyouseeLATCH-CHECKlightgooutandtheCLOSElightcomeson.Thisshouldbeapproximately4inchesfromJamb.Finetuneadjustmentasnecessary.Ifthelightsfailtoworkcallforfactoryassistance.
THE DETEX, LOW ENERGY AUTOMATIC DOOR OPERATOR, IS TO BE USED WITH APPROVED SWITCHES.
ContactfactoryforinformationonSensorconnections.
Typicallyyouwilluseawallmounted,hardwiredpushbuttonforactivation.YoumustprovidewirefromthepushbuttonswitchtotheControlModuleinputs.Knockoutsareavailableontheenclosureforwireruns.Theconnectionsareterminatedonterminals#1and#2oftheControlModule.RefertothediagramincludedwiththeControlModule.
BE SURE ALL WIRING MEETS ALL STATE AND LOCAL CODES.
![Page 8: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/8.jpg)
104851Page8
Button Location
Locatethebuttonssecurelytoawallorpost.Besurethebuttonisnotblockedbyopeneddoororcausetheusertobeinthepathofthedoorleafwhenopening.Checklocalcodesforvariationsinlocationrequirements.
Anotherpopulartypeofbuttonhasbattery-operatedtransmitters.Theyworkwithareceivermountedinoperatorcase.ThereceivermaybeconnectedtotheControlModuleforasourceofpower.Connectpowerwiresto#12and#13forA.C.,or#1and#11forD.C.Connectthe“COM”and“N.O.”outputstoterminals#1and#2ofthecontrolmodule.
Eachtransmittersettingmustbeprogrammedtothesamesettingofthereceivertooperatecorrectly.
PerANSI/BHMAA156.19,switchistobeinstalledwithinviewofdooratamaximumdistanceof144”(3658mm)fromthecenterofthedoorandmountedaminimumof36”(914mm)andamaximum48”(1219mm)fromthefinishedfloor.
![Page 9: DETEX Low Energy Automatic Door Operatoraccesshardware.com/wp-content/uploads/2014/08/...(105422) UDC 1000 Controller (105421) Line Filter (105416-2) Gear Motor (104796-X) Installation](https://reader034.vdocuments.us/reader034/viewer/2022050216/5f61c9acc46dae1c2e720a9f/html5/thumbnails/9.jpg)
104851Page9
Decal Application
You’vebeenprovidedwithadouble-sidedecalthatmeetsANSI/BHMAA156.19,asfollows:Adoorshallbemarkedwithadecal,visiblefromtheswingside,withthewords
“AUTOMATIC CAUTION DOOR”
Thesignshallbemountedondoorataheight58in.+/-5in.fromthefloortocenterlineofthesign.Thesignshallbeaminimumof6in.indiameterwithblackletteringonayellowbackground.
Final Inspection
Beforeleavingsite,testallactivationdevicesandtimeyourdoor.Toreducecall-backs,instructowneronthelegaloperationofdoor,howtoturnonandoff,functionandwarrantyconsiderations.
This operator must be installed/serviced by a qualified person. The service technician must be familiar with the latest
ANSI/BHMA A156.10/19 standards.
Call factory for technical support800-729-3839
Decal(104787)