design of horizontal bracing

3
Design of Horizontal Bracing Connections LOAD COMBINATION: DEAD LOAD+WIND LOAD+TEMPERATURE LO GRADE OF STEEL AS PER IS 2062Fy = 250 MEMBER ID: A101 AXIAL FORCE AS STAAD =P= 113.09 kN MEMBER SIZE = L90x90x8 Sectional Area A = 13.80 Load Data Axial Capacity, T = 155.25 kN > 113.092 KN, OK ( Tc = 0.4 Design for 75 % Axial capacity = 116.4375 kN A) Connection Type-1 ( Bolted Conn.) Alternative Grade of Bolts = 8.8 Dia of Bolts, db = 24 mm oot Area of Bolt = 366.58 Total Nos of bolts (n)= 2 Capacity of Bolt Tensile Stress, Ft = 286 N/mm2 Tension, Tc = 104.84 Shear Stress, Fv = 191 N/mm2 Shear, Vc = 70.02 Shear Check V = Max ( P or 75 % T ) / n Shear per bolt, V = 58.22 kN < Shear Capacity, OK Weld length Calculations Weld Thkness, tw = 6.0 mm 100 Length Reqd, lw = lw Req.= 275 mm Weld Prov. = 2x(90+25+50+50) Weld Prov. = 420 mm Weld Provide is OK A) Profile Welded Connection Weld length Calculations Weld Thkness, tw = 6.0 mm 100 Length Reqd, lw = lw Req.= 275 mm N/mm 2 cm 2 sw = P / ( sw x 0.707 x t ) sw = P / ( sw x 0.707 x t )

Upload: dsananda

Post on 24-Oct-2015

36 views

Category:

Documents


3 download

DESCRIPTION

Worksheet file for calculation of member capacity/adequacy for horizontal bracing. in put can be had from staad & externally can be designed

TRANSCRIPT

Page 1: Design of Horizontal Bracing

Design of Horizontal Bracing Connections

LOAD COMBINATION: DEAD LOAD+WIND LOAD+TEMPERATURE LOAD

GRADE OF STEEL AS PER IS 2062Fy = 250

MEMBER ID: A101

AXIAL FORCE AS STAAD =P= 113.09 kN

MEMBER SIZE = L90x90x8

Sectional Area A = 13.80 Load Data

Axial Capacity, T = 155.25 kN > 113.092 KN, OK ( Tc = 0.45 x Fy x A )

Design for 75 % Axial capacity = 116.4375 kN

A) Connection Type-1 ( Bolted Conn.) Alternative

Grade of Bolts = 8.8

Dia of Bolts, db = 24 mm Root Area of Bolt = 366.58Total Nos of bolts (n)= 2

Capacity of BoltTensile Stress, Ft = 286 N/mm2 Tension, Tc = 104.84 kNShear Stress, Fv = 191 N/mm2 Shear, Vc = 70.02 kN

Shear Check

V = Max ( P or 75 % T ) / n

Shear per bolt, V = 58.22 kN < Shear Capacity, OK

Weld length Calculations

Weld Thkness, tw = 6.0 mm 100Length Reqd, lw =

lw Req.= 275 mm Weld Prov. = 2x(90+25+50+50)Weld Prov. = 420 mm Weld Provide is OK

A) Profile Welded Connection

Weld length Calculations

Weld Thkness, tw = 6.0 mm 100Length Reqd, lw =

lw Req.= 275 mm

N/mm2

cm2

mm2

sw = N/mm2

P / ( sw x 0.707 x t )

sw = N/mm2

P / ( sw x 0.707 x t )

Page 2: Design of Horizontal Bracing

Lw = 2x(90+74)Weld Prov.Lw = 328 mm Weld Provide is OK