dentalez makes your practice perfectc1-preview.prosites.com/106982/wy/docs/custom air mc-201...

67
Vacuum Pumps Technical Manual DentalEZ MAKES YOUR PRACTICE PERFECT ® ®

Upload: others

Post on 13-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Vacuum PumpsTechnical Manual

DentalEZ MAKES YOUR PRACTICE PERFECT® ®

Page 2: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 1

Vacuum Pumps

VACUUM

PUMPS

Specifications ..........................................................iv-2

Certifications ..........................................................iv-3

Site Requirements CV-101 FS / CV-102 FS...........................................iv-4 MC-201 FS / MC-202 FS ........................................iv-5

Water Consumpsion Chart ..........................................................................iv-6

Recirculator Instructions CV-101 FS / CV-102 FS....................................... iv-7-9 MC-201 FS / MC-202 FS ............................... iv-10-12

Maintenance CV-101 FS / CV-102 FS........................................ iv-13 MC-201 FS / MC-202 FS ..................................... iv-14

Air / Water or Nitrous Oxide Separator AM-200 ................................................................... iv-15

Frequently Asked Questions Wire single pump to remote lighted switch .. iv-16 Wire dual pumps to remote lighted switch ... iv-17 One pump weak ................................................... iv-18 Buck-Boost Transformer data ...................... iv-19-20 Wire new transformer in old relay box .......... iv-21 Vacuum relay will not engage & pump will not turn on ................................... iv-22 Pump shuts down, cools then restarts ............ iv-23 Pump makes squealing / whistling sound ......... iv-24 Water leaks from anti-siphon valve .................. iv-25 Dual pump vacuum weak .................................... iv-26

Troubleshooting Vacuum Pump .................................................. iv-27-28 Electrical System ........................................................29

Wiring Schematics CV-101 FS / CV-102 FS........................................ iv-30 MC-201 FS / MC-202 FS ..................................... iv-31 Remote Low-Voltage Switch Control .............. iv-32 Two-Switch Dual Vacuum System ..................... iv-33 One-Switch Dual Vacuum System ..................... iv-34

System Repair Procedure CV-101 FS / CV-102 FS.......................................35-39 MC-201 FS / MC-202 FS ....................................40-44

Parts Lists CV-101 FS / CV-102 FS

Installation Kit .................................................... iv-45 Water Supply Line ............................................ iv-46 Vacuum Line ....................................................... iv-47 Waste Line ......................................................... iv-48 1 HP Single Pump Assembly ........................... iv-49 2 HP Sngle Pump Assembly ............................ iv-50 Electrical Box ..................................................... iv-51 Water Control Assembly ............................... iv-52 Anti-Siphon Valve Assembly ........................... iv-53 Water Solenoid Valve Assembly ................... iv-53 Intake Manifold Assembly ............................... iv-54 Primary/Secondary Filter................................. iv-54

MC-201 FS / MC-202 FS

Water Supply Line ............................................ iv-55 Vacuum Line ....................................................... iv-55 Waste Line ......................................................... iv-56 Electrical Connection Assembly .................... iv-56 Frame Assembly ................................................ iv-57 1 HP Dual Pump Assembly ............................. iv-58 2 HP Dual Pump Assembly ............................. iv-59 Intake Manifold Assembly ................................ iv-60 Exhaust Manifold Assembly ............................. iv-61 Water Recirculator, Exhaust Manifold Assembly (Optional) .................................. iv-61 Electrical Box ..................................................... iv-62 Water Control Assembly ................................ iv-63 Vacuum Control Assembly ............................. iv-64 Vacuum Gauge & Adapter ............................... iv-64 In-Line Filter Assembly .................................... iv-64 Anti-Siphon Valve Assembly ............................ iv-65 Water Solenoid Valve Assembly ..................... iv-65

Page 3: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-2

SPECIFICATIONS

Vacuum Pumps

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

2

This manual contains installation, operation, care andrepair instructions and user service information forthe CustomAir® Dual Wet Vacuum Pump (MC-201 FS/MC-202 FS).

The Dual Wet Vacuum Pump is designed to providetrouble-free service when installed, operated and caredfor according to the procedures set forth in this manual.

Section I Introduction

MotorPower Rating: 1 HP 2 HPVoltage: 208/230 208/230Amps (each motor): 7.5/7.5 15/15Cycle: 60 Hz.Phase: SingleRunning Speed: 3450 RPMAmbient Temperature Range: 10-40°C/50-104°FMax. Oper. Noise Level: 70-75 dB

VacuumMercury Pull (Sealed Sys.): Approx. 20-25" Hg. Adjust.One Pump OperationUsable CFM: 15 30Use factor (Number ofhigh-volume hosesopen simultaneously): 1.5 3Two Pump OperationUsable CFM: 30 60Use factor (Number ofhigh-volume hosesopen simultaneously): 3 6

DimensionsHeight: 23"Width: 24"Depth: 17-1/2"

Shipping Weight: 175 lbs. 215 lbs.

Water RequirementsGallons Per Min. (per pump): 1/2 1

Specifications

MC-201 FS MC-202 FS– Type of protection against electric shock: Class 1

Equipment

– Degree of protection against the ingress of water:Ordinary

– Equipment not suitable for use in the presence ofa flammable anesthetic mixture with air or withoxygen or nitrous oxide.

– Mode of operation: Continuous

– Environmental conditions for transport and storageRecommended ranges:

Classification

Medical Equipment withRespect to Electric Shock,Fire and MechanicalHazardsOnly in Accordance withUL60601-1 andCAN/CSA C22.2 No. 601.1and IEC60601-1-2

- Temperature range within - 40º C to + 70º C- Relative humidity range within 10% to 100%- Atmospheric pressure range within 500 to 1050 hPa

Explanation of Symbols used onEquipment:

Approvals:UL/CUL Classified: File E212679

53HN

= Attention, Consult Accompanying Documents

= Protective Earth Terminal

= Caution. Electrical Shock Hazard. Refer Servicingto Qualified Personnel

= Hot Surface

= European Certification

Installation, Operation and Care Manual

Single Wet Vacuum Pump

2

This manual contains installation, operation, care andrepair instructions and user service information forthe CustomAir® Single Wet Vacuum Pump (CV-101 FS/CV-102 FS).

The Single Wet Vacuum Pump is designed to providetrouble-free service when installed, operated andcared for according to the procedures set forth in thismanual.

Section I Introduction

MotorPower Rating: 1 HP 2 HPVoltage: 115/208/230 208/230Amps (each motor): 15/7.5/7.5 15/15Cycle: 60 Hz.Phase: SingleRunning Speed: 3450 RPMAmbient Temperature Range: 10-40°C/50-104°FWire Size: 12 GA.

VacuumMercury Pull (Sealed Sys.): Approx. 20-25" Hg. Adjust.Usable CFM: 15 30Use factor (Number ofhigh-volume hosesopen simultaneously): 1.5 3

Water RequirementsGallons Per Minute: 1/2 1

DimensionsHeight: 16" 20"Width: 12" 14"Depth: 9" 11"

Shipping Weight: 68 lbs. 78 lbs.

Approvals:UL/CUL Classified: File: E212679

Specifications

CV-101 FS CV-102 FS

= Attention, Consult Accompanying Documents

= Protective Earth Terminal

= Caution. Electrical Shock Hazard. Refer Servicingto Qualified Personnel

= Hot Surface

= European Certification

– Type of protection against electric shock: Class 1Equipment

– Degree of protection against the ingress of water:Ordinary

– Equipment not suitable for use in the presence ofa flammable anesthetic mixture with air or withoxygen or nitrous oxide.

– Mode of operation: Continuous

– Environmental conditions for transport and storageRecommended ranges:

Classification

Medical Equipment withRespect to Electric Shock,Fire and Mechanical HazardsOnly in Accordance withUL60601-1 andCAN/CSA C22.2 No. 601.1and IEC60601-1-2

- Temperature range within - 40º C to + 70º C- Relative humidity range within 10% to 100%- Atmospheric pressure range within 500 to 1050 hPa

Explanation of Symbols used onEquipment:

53HN

Page 4: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 3

CERTIFICATIONS

Vacuum Pumps

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

2

This manual contains installation, operation, care andrepair instructions and user service information forthe CustomAir® Dual Wet Vacuum Pump (MC-201 FS/MC-202 FS).

The Dual Wet Vacuum Pump is designed to providetrouble-free service when installed, operated and caredfor according to the procedures set forth in this manual.

Section I Introduction

MotorPower Rating: 1 HP 2 HPVoltage: 208/230 208/230Amps (each motor): 7.5/7.5 15/15Cycle: 60 Hz.Phase: SingleRunning Speed: 3450 RPMAmbient Temperature Range: 10-40°C/50-104°FMax. Oper. Noise Level: 70-75 dB

VacuumMercury Pull (Sealed Sys.): Approx. 20-25" Hg. Adjust.One Pump OperationUsable CFM: 15 30Use factor (Number ofhigh-volume hosesopen simultaneously): 1.5 3Two Pump OperationUsable CFM: 30 60Use factor (Number ofhigh-volume hosesopen simultaneously): 3 6

DimensionsHeight: 23"Width: 24"Depth: 17-1/2"

Shipping Weight: 175 lbs. 215 lbs.

Water RequirementsGallons Per Min. (per pump): 1/2 1

Specifications

MC-201 FS MC-202 FS– Type of protection against electric shock: Class 1

Equipment

– Degree of protection against the ingress of water:Ordinary

– Equipment not suitable for use in the presence ofa flammable anesthetic mixture with air or withoxygen or nitrous oxide.

– Mode of operation: Continuous

– Environmental conditions for transport and storageRecommended ranges:

Classification

Medical Equipment withRespect to Electric Shock,Fire and MechanicalHazardsOnly in Accordance withUL60601-1 andCAN/CSA C22.2 No. 601.1and IEC60601-1-2

- Temperature range within - 40º C to + 70º C- Relative humidity range within 10% to 100%- Atmospheric pressure range within 500 to 1050 hPa

Explanation of Symbols used onEquipment:

Approvals:UL/CUL Classified: File E212679

53HN

= Attention, Consult Accompanying Documents

= Protective Earth Terminal

= Caution. Electrical Shock Hazard. Refer Servicingto Qualified Personnel

= Hot Surface

= European Certification

File # 1371

Page 5: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-4

CV101FS / CV102FS

SITE

REQUIREMENTS

3Single Wet Vacuum Pump

The following Pre-installation information will assistin making a quick, easy and quality installation. How-ever, if there are any questions, contact a CustomAirtechnical service representative at 1-866-DTE-INFO.

Section II Pre-installation

Site Requirements

ElectricalAll electrical supply lines and control wiring should besupplied and installed by a licensed electrician accord-ing to local building codes.

Before the Single Wet Vacuum Pump can be properlyinstalled, the following utilities must be available:

WaterWater line must be installed by a plumber accordingto local building codes. Requirements: 1/2" gatevalve reduced to 1/8" FIP.

WasteWaste line must be installed by a plumber accordingto local building and health codes. Requirements:reduce connection to 1" FIP or floor sink. Whenusing floor sink, order a floor sink adapter.

Vacuum LinesVacuum lines must be installed by a plumber accord-ing to local building and electrical codes. Require-ments: 1" IPS, PVC, Schedule 40.

stloV *SF101-VCledoM SF201-VCledoM

V511 ybtceridderiWrepsanaicirtcele

.sedoclacolhtiwtiucricetarapeS

,rekaerbpma03.esahpelgnis

ebtonnaCV511otdetcennoc

.enil

V032/802 ybtceridderiWrepsanaicirtcele

.sedoclacolhtiwtiucricetarapeS

,rekaerbpma02.esahpelgnis

ybtceridderiW.naicirtcele

htiwtiucricetarapeS,rekaerbpma03

.esahpelgnis

Electrical Requirements

*Model CV-101 FS is manufactured and shipped for115V operation. This model may be converted to 230Voperation by qualified installation technicians only follow-ing connection diagrams inside the pump control box.

Low Voltage Control Line (Optional)If remote low voltage is desired, a licensed electricianshould install 18-2 thermostat wire from the pumplocation to the operatory switches. (Use 18-3 thermostatwire for lighted switch.)

Vacuum Line1" IPS, PVC,Schedule 40

Water Line1/2" Gate Valve

Reduced to1/8" FIP

Low Voltage Line24V (Optional)

Electrical115V or 230V

Connection Box

Waste Line"P" Trap Reduced

to 2" FIP

Floor SinkUse Floor Sink

Adapter

Page 6: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 5

MC201FS / MC202FS

SITE

REQUIREMENTS

3Dual Wet Vacuum Pump

epyTnoitcetorP)rotomhcae(

SF102-CMV032

SF202-CMV032

rekaerBtiucriC spmA02 spmA03

esuFyaleDemiT spmA21 spmA02

esuFdradnatS spmA52 spmA04

The following Pre-installation information will assistin making a quick, easy and quality installation. How-ever, if there are any questions, contact a CustomAirtechnical service representative at 1-866-DTE-INFO.

Section II Pre-installation

Site Requirements

WaterWater line must be installed by a plumber accordingto local building codes. Terminate water line in 1/2"FIP gate valve.

Waste

Motor Protection Chart

Low Voltage Control Line (Optional)

If remote low voltage is desired, a licensed electricianshould install 18-3 thermostat wire for lighted switch or18-2 thermostat wire for non-lighted switch from the pumplocation to the operatory switch located up to 150 feetaway. If the operatory switch is over 150 feet away fromthe pump location, use 16-3 thermostat wire for lightedswitch or 16-2 thermostat wire for non-lighted switch.

Before the Dual Wet Vacuum Pump can be properlyinstalled, the following utilities must be supplied:

ElectricalAll electrical supply lines and control wiring should besupplied and installed by a licensed electrician accord-ing to local building codes. The Dual Wet VacuumPump requires two separate circuits (one for eachpump motor) of the correct voltage for the systemordered. In addition to the thermal overload protectionbuilt into the motors, each circuit must be providedwith a circuit breaker, time delay fuse or standardfuse. See the Motor Protection Chart below forrecommended breaker or fuse amperage.

— IMPORTANT —All vacuum systems must be installed accord-

ing to local building and electrical codes.Vacuum Line

(IPS, PVC,Schedule 40)

Water Line(1/2" Gate Valve

Reduced to3/8" FIP)

Low Voltage Line(24V) (Optional)

Electrical(230V)

ConnectionBoxes (2)

Waste Line(Drain)

Waste line must be installed by a plumber accordingto local building and health codes. For requirements,see Typical Installation Options, Page 4 and WasteLine, Page 6.

Vacuum LinesVacuum lines be installed by a plumber according tolocal building codes. Vacuum lines and risers to beIPS, PVC, Schedule 40, unless local codes requireanother material such as copper. Slope all vacuumlines toward the vacuum producer 1 inch for every 20foot run. Make all vacuum line connections usinglong radius sweep fittings.

— CAUTION —A free-flowing discharge system is required forproper operation of the vacuum system. Thedual pump may leak at the anti-siphon valve ifthe discharge system is restricted. Ensure the

vacuum system is installed and cleaned in accor-dance to the instructions in this manual.

Page 7: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-6

WATER

CONSUMPTION

Wet Vacuum Pumps

Model # Gal. per hour w/o recirculator Gal. per hour w/recirculatorCV-101 30 5 - 6CV--102 60 9 - 10

MC-201 w/one pump running 30 5 - 6MC-201 w/both pumps running 60 9 - 10MC-202 w/one pump running 60 9 - 10

MC-202 w/both pumps running 120 18 - 20Note: Figures are for continuous operation.

Vacuum Pump Water Consumption Chart

Page 8: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 7

CV-101FS / CV102FS

RECIRCULATOR

INSTRUCTIONS

Page 1 of 3

INSTALLATION INSTRUCTIONS

���DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 1-866-DTE-INFO

October, 2001

64710022CSingle Pump Water Recirculator

�������������������������������������������������������

�����������������������������������������������������������������������������������

Mounting

�� ��������������������������������������������������������������������������������������

�� �������������������������������������������������������������������������������������������

�� ���������������������������������������������������������������������������������������������������

�� ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

�� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

10

RemoveHose

1

2

13

To Drain

3

4

17 7

9

6

8

16

18

3

Page 9: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-8

CV-101FS / CV102FS

RECIRCULATOR

INSTRUCTIONS

Page 2 of 3

Pump Exhaust

�� ���������������������������������������������������������������������������������������������

�� �����������������������������������������������������������������������������������������������������������������������

�� ��������������������������������������������������������������������������������������������������������������������

Water Supply

�������������������������������������������������������������������������������������������������

�� �������������������������������������������������������������������

�� ����������������������������������������������������������������������

�� ���������������������������������������������������������������������

�� ��������������������������������������������������

�� �������������������������������������������������������������������������������������������������������������������

� ������������������������������������������� ������������������������������������������

�� ������������������������������������������������������������������������������������������������������� ��������������������������

�� �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

�� ������������������������������������������������������������������������������������

�� ������������������������������������������������������������������������������������������������������

��� ����������������������������������������������������������������������������������������������������

��� �������������������������������������������������������������������������������������������������������������������������

Operation Check

�� ���������������������������������������������������������������������������������������

�� ��������������������������

Single Pump Water Recirculator

(On next page)

Page 10: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 9

CV-101FS / CV102FS

RECIRCULATOR

INSTRUCTIONS

Page 3 of 3

64710022C

View A

View B

View C

10

11

18

11

19

12

101410

13

Housing ElbowThreaded Hole

5

15

10

Page 11: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-10

MC-201 FS / MC-202 FS

RECIRCULATOR

INSTRUCTIONS

Page 1 of 3

INSTALLATION INSTRUCTIONS

���DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 1-866-DTE-INFO

October, 2001

64710012CDual Pump Water Recirculator

�������������������������������������������������������

�����������������������������������������������������������������������������������

Mounting

�� ������������������������������������������������������������������������������������

�� ���������������������������������������������������������������������������

�� �����������������������������������������������������������������������������������������������������������������

�� ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

�� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

10

RemoveHose

RemoveHose

1

2

15

13

To Drain

3

4 5 17 7

9

6 8

16

18

�������������������������������������������������������������������������������������������������������������������������������������������������������

Page 12: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 11

RECIRCULATOR

INSTRUCTIONS

MC-201 FS / MC-202 FS

Page 2 of 3

Pump Exhaust

�� �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

�� ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������

Water Supply

�������������������������������������������������������������������������������������������������

�� �������������������������������������������������������������������

�� ����������������������������������������������������������������������

�� ���������������������������������������������������������������������

�� �������������������������������������������������������������������������������������������������������������������

� ������������������������������������������� ������������������������������������������

�� ������������������������������������������������������������������������������������������������������� ��������������������������

�� �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

�� ������������������������������������������������������������������������������������

�� ���������������������������������������������������������������

�� ������������������������������������������������������������������������������������

��� ���������������������������������������������������������������������������������������������������������������������������������������

��� ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

Operation Check

�� ���������������������������������������������������������������������������������������

�� ��������������������������

Dual Pump Water Recirculator

(On next page)

Page 13: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-12

RECIRCULATOR

INSTRUCTIONS

MC-201 FS / MC-202 FS

Page 3 of 3

64710012C

View A

View B

View C

10

11

10

11

19

12

101410

13

Housing ElbowThreaded Hole

Page 14: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 13

MAINTENANCE

CV-101 FS / CV-102 FS

19Single Wet Vacuum Pump

Section VI Operation & Care

— WARNING —Before starting cleaning procedures, make

certain to put on eye protection, a mask andpuncture-resistant nitrile gloves.

Weekly Maintenance

Clean In-Line Filter

Turn OFF the pump motors.

Carefully unscrew the lower bowl from the filtertop and lift out the screen.

Using water, flush the bowl assembly and anycontaminated sediment.

Submerge the screen/bowl assembly into a high-level chemical disinfectant solution. Follow thedisinfectant manufacturer's recommendation for timeinterval required to achieve disinfection.

Remove the screen/bowl assembly from thedisinfectant solution and rinse using tap water.

Properly dispose of the contaminated sedimentand disinfectant solution waste.

Replace the screen and make sure the gasket is inplace before replacing the bowl.

Check all connecting vacuum, waste and waterlines for tightness.

Inspect Operatory FiltersCheck and clean all operatory and secondaryfilters weekly. Follow the equipment manufacturer'srecommendations.

Inspect Vacuum SystemCheck the system weekly for water leaks and looseor broken connections.

Monthly Maintenance

Check Vacuum Level

The vacuum level of the CustomAir Single WetVacuum Pump is preset at the factory.

Recommended Operating Vacuum Levels:10" Hg. General Dentistry19" Hg. Surgery

The pressure gauge will indicate the vacuum levelprovided by the pump. If it becomes necessary toadjust this setting, the following steps can betaken:

NOTE: The evacuator should be left ON whensetting the vacuum level. Also, make sure all hosesin the operatory are closed.

Turn the lock nut counterclockwise to loosen.

For greater vacuum level, turn the screwclockwise; for less vacuum level, turn screwcounterclockwise.

Set to desired vacuum level and tighten locknut.

Clean SurfaceUsing a damp cloth, remove any surface dust anddirt.

— CAUTION —A free-flowing discharge system is required forproper operation of the vacuum system. The

pump systems may leak at the anti-siphon valveif the discharge system is restricted. Ensure thevacuum system is installed and cleaned in accor-

dance to the instructions in this manual.

Page 15: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-14

MC-201 FS / MC-202 FS

MAINTENANCE

21Dual Wet Vacuum Pump

Section VI Operation & Care

— WARNING —Before starting cleaning procedures, make

certain to put on eye protection, a mask andpuncture-resistant nitrile gloves.

Weekly Maintenance

Clean In-Line Filter

Turn OFF the pump motors.

Carefully unscrew the lower bowl from the filtertop and lift out the screen.

Using water, flush the bowl assembly and anycontaminated sediment.

Submerge the screen/bowl assembly into a high-level chemical disinfectant solution. Follow thedisinfectant manufacturer's recommendation for timeinterval required to achieve disinfection.

Remove the screen/bowl assembly from thedisinfectant solution and rinse using tap water.

Properly dispose of the contaminated sedimentand disinfectant solution waste.

Replace the screen and make sure the gasket is inplace before replacing the bowl.

Check all connecting vacuum, waste and waterlines for tightness.

Inspect Operatory FiltersCheck and clean all operatory and secondaryfilters weekly. Follow the equipment manufacturer'srecommendations.

Inspect Vacuum SystemCheck the system weekly for water leaks andloose or broken connections.

Monthly Maintenance

Check Vacuum Level

The vacuum level of the CustomAir Dual WetVacuum Pump is preset at the factory.

Recommended Operating Vacuum Levels:10" Hg. General Dentistry19" Hg. Surgery

The pressure gauge will indicate the vacuum levelprovided by the pump. If it becomes necessary toadjust this setting, the following steps can betaken:

NOTE: Turn On one pump — vacuum leveladjustments are made with only one pump operative.

Turn the lock nut counterclockwise to loosen.

For greater vacuum level, turn the screwclockwise; for less vacuum level, turn screwcounterclockwise.

Set to desired vacuum level and tighten locknut.

NOTE: The evacuator should be left ON whensetting the vacuum level. Also, make sure all hosesin the operatory are closed.

Clean SurfaceUsing a damp cloth, remove any surface dust anddirt.

Page 16: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 15

AM-200

AIR/

WATER

SEPARATOR

Model: AM-200Air/Water or Nitrous Oxide Separator

(PN: 64656200)

Compatible with all single ordual water injected vacuumpumps. Parts provided for unitto be adapted to 3/4", 1" or1-1/2" exhausts.

2500 Highway 31 SouthBay Minette, Alabama 36507

1-866-DTE-INFO

Air discharge vent to outsidesupplied by plumber

3/4" or1"

Exhaust

1-1/2"Exhaust

CleanOutPlugWater to

Drain

PN: 64710078C

A standard 2", no-hub coupling onthe air discharge vent eliminatesany adaptor and allows directhookup to a standard vent pipe.

The water trap is inside, whichmakes plugging virtually impossible.

The entire separator is made ofcorrosion-proof PVC plastic.

The separator should bemounted near the vacuum pumpwith the center of the exhaustsinlets on the chamber no morethan 2 feet above the bottom ofthe vacuum pump.

NOTE: This product should beinstalled by a competent technicianor plumber. The installation shouldmeet all local health and plumbingcodes. This device requires a separateatmospheric vent for maximumsafety and effectiveness.

Page 17: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-16

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

How is a single pump wired to a remote lighted switch?

IMPORTANT NOTE:If not using a DentalEZMaster Control Panel Kit,proceed as follows:

1. Position the masterswitch in the desiredlocation.

2. Run the appropriate wiresto their respectiveeuipment location. (Seewiring chart below.)

3. Connect wires accordingto the wiring diagram onthe right.

WIRING CHART

— WARNING —Before proceeding with any electrical installation, comply with and

maintain all applicable local electrical code(s) and regulations.

— NOTICE —All wiring between the main control box and equipment should be Class B, low-

voltage. In most cases, a conduit is not required when using this type of wiring.

CV-101 3 18 AWG 16 AWGCV-102 3 18 AWG 16 AWG

Model No. No. of W ires W ire Under 150 ft. W ire Over 150 ft.

Wall-Mounted Switches Shown from

Back of Switch Plate Vacuum

Junction Box

Line Voltage(To Source)

Load(To Vacuum Pump)

Vacuum PumpRelay Box

Brown

Yellow

Black

L1

L2 T2

T1

LEGENDBrown = LightYellow = ReturnBlack = Power

FAQ #1

Page 18: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 17

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

L1

L2 T2

T1

Wall-Mounted Switch

Shown from Back of

Switch Plate

Junction Box

Vacuum PumpRelay Box

Brown

YellowBlack

ON/OFF Switches Mounted on Dual Frame

Vacuum

Brown

YellowBlack

Line Voltage(To Source)

Load(To Vacuum

Pump)

L1

L2 T2

T1

Line Voltage(To Source)

Load(To Vacuum

Pump)

Ret

urn

Light Common

Pow

er

Light Common

Vacuum PumpRelay Box

MC-201 6 18 AW G 16 AW GMC-202 6 18 AW G 16 AW G

How are dual pumps wired to a remote lighted switch?

IMPORTANTNOTE: If notusing a DentalEZMaster ControlPanel Kit, proceed asfollows:

WIRING CHART

— WARNING —Before proceeding with any electrical installation, comply with and

maintain all applicable local electrical code(s) and regulations.

— NOTICE —All wiring between the main control box and equipment should be Class B, low-

voltage. In most cases, a conduit is not required when using this type of wiring.

Model No. No. of Wires Wire Under 150 ft. Wire Over 150 ft.

LEGENDBrown = LightYellow = ReturnBlack = Power

1. Position themaster switchin the desiredlocation.

2. Run theappropriatewires to theirrespectiveeuipmentlocation. (Seewiring chartbelow.)

3. Connectwiresaccording tothe wiringdiagram onthe right.

FAQ #9

Page 19: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-18

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

Cle

an o

r re

plac

e ch

eck

valv

e on

the

rig

ht s

ide

of t

he in

take

man

ifold

.PN

: 645

6819

1, 3

/4"

PN: 6

4568

193,

1"

Why

is o

ne p

ump

wea

k?D

oes

the

dual

pum

p ha

vea

wat

er r

ecir

cula

tor?

Doe

s th

e pu

mp

have

suffi

cien

t w

ater

sup

ply?

Che

ck li

nes

from

rec

ircu

lato

rto

inta

ke li

nes.

Are

the

y cl

ogge

d?

Che

ck w

ater

flow

from

res

tric

tor

toth

e im

pelle

r ho

usin

g.Is

flow

suf

ficie

nt?

Hav

e el

ectr

icia

n pr

ovid

epr

oper

pow

er s

uppl

y.

Cor

rect

wat

er s

uppl

y:1

HP

= 1

/2 g

al. p

er m

in.

2 H

P =

1 g

al. p

er m

in.

Cle

an o

r re

plac

eflo

w r

estr

icto

rs.

PN: 6

4568

192,

1 H

PPN

: 646

2201

0, 2

HP

No

Yes

Cle

an li

nes

and

mak

e su

rere

circ

ulat

or c

lean

er is

used

onc

e a

mon

th.

With

the

left

pum

p ru

nnin

g,re

mov

e th

e in

take

hos

e fr

om t

heri

ght

pum

p. Is

vac

uum

pre

sent

?

Yes

No

Is t

he v

olta

ge t

o th

eva

cuum

pum

ps c

orre

ct?

Che

ck im

pelle

r ho

usin

gfo

r w

ear

or b

uild

up.

Yes

No

Yes

No

Yes

No

No

No

Yes

Yes

With

the

rig

ht p

ump

runn

ing,

rem

ove

the

inta

ke h

ose

from

the

left

pum

p.Is

vac

uum

pre

sent

?

Cle

an o

r re

plac

e ch

eck

valv

e on

the

left

sid

e of

the

inta

ke m

anifo

ld.

PN: 6

4568

191,

3/4

"PN

: 645

6819

3, 1

"

FAQ

#11

Page 20: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 19

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

FAQ #12Page 1 of 2

Page 21: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-20

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

FAQ #12Page 2 of 2

Page 22: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 21

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

How is a new transformer wired in an old relay box?(V Series)

GR

EEN

&Y

ELLO

W

LIG

HT

BLU

E

TER

MIN

AL

BLO

CK

(646

1502

3)

RED

BRO

WN REL

AY

(645

6813

3)

TR

AN

SFO

RM

ER(6

4637

018)

RED

SPA

RE

FUSE

HO

LDER

(645

6100

5)

RPL

. 115

V F

USE

(64

5681

31)

RPL

. 230

V F

USE

(64

5681

30)

FUSE

HO

LDER

(645

6816

0)

BLA

CK

(646

2508

3)BR

OW

N(6

4625

085)

PUR

PLE

(646

2507

3)

YEL

LOW

(646

2508

4)

BRO

WN

&W

HIT

E(6

5625

074)

BLA

CK

(646

2507

7)

BLU

E (6

4625

063)

YEL

LOW

(646

2508

2)

TER

MIN

AL

BLO

CK

JUM

PER

(64

6150

21)

BRO

WN

(646

2508

9)

CIR

CU

ITBR

EAK

ER

RPL.

15

AM

P B

REA

KER

(380

2-12

0)RP

L. 8

AM

P B

REA

KER

(380

1-91

1)

65

43

02

1

RED

WHITEBLUEBROWNBLACK

65

43

21

Yellow

Transformer

Fuse Holder

Alt. VoltageFuse Holder

Brown/White

Purple

Black

TerminalBlock

Black

Black

Blue

Yellow

Black/White

Brown

Red

White

Green

Relay

Blue

Black

Yellow

Brown

Yellow

New Transformer Old Relay Box

FAQ #13

Page 23: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-22

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

Why

wo

n't

the

vacu

um r

elay

eng

age

and

the

pum

p do

esn'

t tu

rn o

n?St

artin

g Le

tter

of S

eria

l #A

, C, D

, S

or V

AC

Vol

tage

acr

oss

2ye

llow

wir

es o

n re

lay

read

s <

20V

or

>20

V

AC

Vol

tage

acr

oss

2ye

llow

wir

es o

n re

lay

read

s >

17V

or

<17

V

Rep

lace

rel

ayPN

: 645

6813

3

Rep

lace

tra

nsfo

rmer

PN: 6

4568

195

Hav

e el

ectr

icia

nin

stal

l a b

uck/

boos

ttr

ansf

orm

er(2

if a

dua

l sys

tem

)

AC

Vol

tage

acr

oss

light

blu

e an

d br

own

wir

es o

n le

ft s

ide

of r

elay

is <

200V

on

230V

pum

p or

<10

0V o

n 11

5V p

ump

AC

Vol

tage

acr

oss

blac

k an

d pu

rple

wir

es o

n le

ft s

ide

of r

elay

is<

208V

on

230V

pum

p or

<11

0V o

n 11

5V p

ump

C, D

, S o

r VA

>17V

<17V

>20V

<20V

Yes

Yes

No

No

FAQ

#23

Page 24: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 23

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

Che

ck li

ne fr

omth

e re

circ

ulat

or.

Is it

clo

gged

?

Why

do

es t

he v

acuu

m p

ump

shut

dow

n, c

oo

l the

n re

star

t?D

oes

pum

p ha

vepr

oper

vol

tage

? Hav

e el

ectr

icia

npr

ovid

e pr

oper

vol

tage

.D

oes

pum

p ha

vesu

ffici

ent

wat

er s

uppl

y?

Che

ck s

haft

rota

tion.

Isit

smoo

th?

Rep

lace

pum

p. P

robl

emis

in w

indi

ngs

of m

otor

.

Che

ck w

ater

from

flow

rest

rict

or. I

s th

ere

suffi

cien

t w

ater

?1

HP

= 1

/2 g

al. p

er m

in.

2 H

P =

1 g

al. p

er m

in.

Do

low

erre

build

.*

No

Yes

Doe

s pu

mp

have

a re

circ

ulat

or?

Hav

e pl

umbe

r su

pply

prop

er w

ater

req

uire

men

ts.

Yes

No

Rep

lace

mot

or.*

Che

ck im

pelle

r ho

usin

gfo

r w

ear

or b

uild

up.

Is t

here

wea

r or

bui

ld u

p?

Yes

No

Yes N

oYe

s

No

No

No

Yes

Yes

* Fo

r pa

rt #

info

rmat

ion

cont

act T

ech

Serv

ice a

t 1-8

66-D

TE-IN

FO.

Cle

ar c

log

and

mak

esu

re r

ecir

cula

tor

clea

ner

is u

sed

once

a m

onth

.

Cle

an o

r re

plac

eflo

w r

estr

icto

rs.

PN: 6

4568

192,

1 H

PPN

: 646

2201

0, 2

HP

FAQ

#29

Page 25: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-24

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

Rep

lace

pum

pm

otor

or

pum

pca

rtri

dge.

*

Why

do

es p

ump

mak

e sq

ueal

ing/

whi

stlin

g so

und?

Che

ck V

olta

geIs

it c

orre

ct?

Cor

rect

ele

ctri

cal

prob

lem

s.R

emov

e in

take

hos

e fr

om p

ump.

Doe

s no

ise

go a

way

?

Cor

rect

wat

erflo

w p

robl

ems.

Rec

onne

ct in

take

hos

e.T

hen

disc

onne

ct t

he h

ose

to t

he v

acuu

m r

elie

f val

ve.

Doe

s no

ise

go a

way

?

No

Yes

Insp

ect

chec

kva

lve.

Is it

wor

king

pro

perl

y?

Man

ually

rot

ate

the

pum

p sh

aft.

Doe

s th

e sh

aft

feel

rou

gh?

Yes

No

Rep

lace

che

ck v

alve

.3/

4" -

PN

: 645

6819

11"

- P

N: 6

4568

193

Cal

l Tec

hnic

alSe

rvic

e.

Yes

No

Yes

No

No

No

Yes

Yes

Che

ck w

ater

flow

to

pum

p. Is

it c

orre

ct?

Che

ck o

r re

plac

eva

cuum

rel

ief v

alve

.PN

: 646

2200

1

* Co

ntac

t Tec

h Se

rvice

at 1

-866

-DTE

-INFO

.

FAQ

#32

Page 26: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 25

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONSW

hy d

oes

wat

er le

ak fr

om

the

ant

i-si

pho

n va

lve?

Sing

le o

rdu

al p

ump?

Is p

ump

runn

ing?

Are

bot

h an

ti-si

phon

valv

es le

akin

g?

Rep

lace

or

rebu

ildan

ti-si

phon

val

ve.

Reb

uild

kit

- PN

: 645

6801

6N

ew V

alve

- P

N: 6

4622

011

Dua

lS

ingl

e

Turn

pum

p of

f. D

isco

nnec

t dr

ain

line

and

let

exha

ust

into

buc

ket.

Turn

pum

p on

. Doe

s le

akin

g st

op?

No

Che

ck fl

ow t

hrou

gh fl

owre

stri

ctor

s. Is

it c

orre

ct?

1 H

P -

1/2

GPM

2 H

P -

1 G

PM1

HP

w/r

ecir.

- .1

3 G

PM2

HP

w/r

ecir.

- .2

5 G

PM

Are

pum

ps r

unni

ng?

Yes

Yes

No

No

No

Yes

Rep

lace

wat

er s

olen

oid

valv

e.24

V- P

N: 6

4568

156

115V

- P

N: 6

4622

084

220V

- P

N: 6

4622

085

Yes

Yes

Hav

e pl

umbe

r cl

ear

obst

ruct

ion

in d

rain

line

.R

epla

ce fl

ow r

estr

itor.

1 H

P -

PN: 6

4568

192

2 H

P -

PN: 6

4622

010

1 H

P w

/rec

ir. -

PN

: 646

2201

82

HP

w/r

ecir.

- P

N: 6

4622

019

No

No

Yes

No

Yes

Is p

ump

runn

ing?

Turn

pum

p/s

off.

Dis

conn

ect

drai

n lin

e an

d le

t ex

haus

tin

to b

ucke

t. Tu

rn p

ump/

s on

. Doe

s le

akin

g st

op?

Rep

lace

wat

er s

olen

oid

valv

e.24

V- P

N: 6

4568

156

115V

- P

N: 6

4622

084

220V

- P

N: 6

4622

085

FAQ

#33

Page 27: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-26

Vacuum Pumps

FREQUENTLY

ASKED

QUESTIONS

Is t

he in

-line

filte

r cl

ean?

Why

is v

acuu

m fr

om

dua

l pum

p w

eak?

Are

wat

er li

nes

from

rec

ircu

lato

r to

inta

ke li

nes

clog

ged?

Are

bot

hpu

mps

run

ning

? Is t

here

a s

uffic

ient

am

ount

of

fres

h w

ater

goi

ng in

to t

he p

umps

?1

HP

= 1

/2 g

al. p

er m

in. p

er p

ump

2 H

P =

1 g

al. p

er m

in. p

er p

ump

No

Cle

an o

r re

plac

eth

e ch

eck

valv

e.PN

: 645

6819

1 -

3/4"

che

ck v

alve

PN: 6

4568

193

-1"

che

ck v

alve

Rem

ove

the

inta

ke h

ose

from

the

pum

p th

at is

not

runn

ing.

Is t

here

vac

uum

pres

ent

on t

hat

hose

?

Yes

No

Yes

No

Yes

No

No

No

Con

tact

Tec

hnic

alSe

rvic

e.1-

866-

DT

E-IN

FO

No

Yes

Yes

Cle

an o

r re

plac

e th

ein

-line

filte

r sc

reen

.

Loca

te a

nd r

epai

r le

aks

in t

he o

pera

tory

line

.

Cle

an b

lock

ages

/cl

ear

rest

rict

ions

.

Doe

s th

e du

alpu

mp

have

aw

ater

rec

ircu

lato

r?

Yes

Yes

Cle

an c

logg

edlin

es a

nd c

lean

out

wat

erre

cicu

lato

r. D

oes

vacu

um in

crea

se?

Any

res

tric

tions

in t

he e

xaus

t lin

e?

FAQ

#43

Rem

ind

offic

est

aff t

he im

port

ance

of u

sing

rec

ircu

lato

rcl

eane

r(P

N: 6

4568

129)

once

a m

onth

.

No

Unh

ook

the

inta

kelin

e fr

om t

he o

pera

tory

line

and

seal

off

the

vacu

um r

elie

f muf

fler.

Doe

s va

cuum

incr

ease

?

Is t

he a

mou

nt o

f fre

sh w

ater

goin

g in

to t

he p

umps

cor

rect

?1

HP

= .1

3 ga

l. pe

r m

in. p

er p

ump

2 H

P =

.25

gal.

per

min

. per

pum

p

Cle

an o

r re

plac

eth

e flo

w r

estr

icto

rs.

PN: 6

4568

192

-1

HP

=1/

2 ga

l. pe

r m

in.

PN: 6

4622

010

-2

HP

= 1

gal

. per

min

.

Cle

an o

r re

plac

eth

e flo

w r

estr

icto

rs.

PN: 6

4622

018

- 1

HP

PN: 6

4622

019

- 2

HP

NO

TE

: If t

he r

ecirc

ulat

orw

as fi

eld

inst

alle

d,th

ere

may

be

2 flo

wre

stric

tors

on

each

Pum

p.

Cle

an o

r re

plac

eth

e flo

w r

estr

icto

rs.

PN: 6

4622

018

- 1

HP

PN: 6

4622

019

- 2

HP

NO

TE

: If t

he r

ecirc

ulat

orw

as fi

eld

inst

alle

d,th

ere

will

be 2

flow

rest

ricto

rs o

n th

e un

it.

Any

blo

ckag

es in

the

drai

n lin

e?

Yes

No

Yes

No

Yes

No

Yes

Page 28: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 27

Wet Vacuum Pumps

TROUBLESHOOTING

Installation, Operation and Care Manual

Single Wet Vacuum Pump

20

motpmyS )s(esuaCelbissoP noituloS

lliwpmuPnurton

nekorbroesoolrofseriwllakcehCwolkcehC.esufkcehC.snoitcennoc

sdaelegatlov )seriwkcalbdnawolley(.stlov42rof

fieesotgnihctawffodnanorewopnruT.ylreporpsetareporabrekaerbyaler

ssarbgninesoolybevlavdionelostseThtiwtuoswolfretawfI.edisthgirnotun

wolfretaW.fforewopnrut,norewop.potsdluohs :noituaC tonoD etarepo

esuaceb,emitdednetxenarofpmupehtdluocretawtuohtiwpmupehtgninnur

.egamadlanretniesuac

ehtecalper,tneserptonsiegatlovfI.esufroremrofsnart eesoslA(

).trahCsmelborPlacirtcelE

dna,ylreporpgnitarepotonyalerfI,doogerastraprehtollagnimussa

.yalerehtecalper lacirtcelEeesoslA().trahCsmelborP

rewophtiwpotstonseodwolfretawfI.evlavdionelosehtecalper,ffo

spotsrotoMtonlliwro

trats

-woldnaffo-tucniam,rekaerbtiucriCehtnierasehctiwsyrotarepoegatlov

FFO .noitisop

.nideggulptonsitinU

.seriwnekorbroesooL

.roticapacdabagnitacidnismuhrotoM

.rotomysionrothgiT

.gnitaehrevosirotoM

nisehctiwsecalP NO .noitisop

.tinunigulP

.seriwecalperroriaper,nethgiT

.roticapacecalpeR

sipmuperusekaM.sgniraebkcehC,rO.rotomehtotdemmihsylreporp

.pmupehtnisirbedynaevomer

sievlavfeilermuucavehterusekaMsahrotomehtdnaylreporpdetsujda

.ylppusretawdnanoitalitnevtneiciffus.egatlovenilwolrofkcehC

• Model Name

• Model Number

• Serial Number

• Installation Date

The following troubleshooting charts should be usedwhen attempting to isolate CustomAir Single WetVacuum Pump operational problems.

If the problem is not addressed in the trouble shoot-ing chart or cannot be isolated by performing thesuggested procedures, contact your local DentalEZfull-service dealership.

Service Instruction

Vacuum Pump

Be prepared to supply the following product informa-tion:

Section VII User Service Information

(On Page 29)

(On Page 29)

Page 29: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-28

Wet Vacuum Pumps

TROUBLESHOOTING

21Single Wet Vacuum Pump

motpmyS )s(esuaCelbissoP noituloS

tonpmuPgninnur

foesuacebtcepsus

lacirtcelemelborp

esufnwolbsahylppusrewopniaM.rekaerbtiucricro

ropmupgnihcaertonrewoP.egatlovtcerrocni

.xoblortnocehtniesufnwolB

ehtedisnisnoitcennocesooL.xoblortnoc

.rekaerbtiucricteserroesufnwolbecalpeR

laudehtfoedisehtnoxobnoitcennockcehCpmupehtgnihcaersirewopyfirevottenibac

.egatlovtcerrocehtsiylppusrewopniamdna

detaremasehthtiwesufehtecalpeR.yrotcafehtmorfenoehtsayticapac

yllausivdnarevocxoblortnocehtevomeR.snoitcennocesoolroftcepsni ehtotrefeR(

rofrevocxoblortnocehtedisnicitamehcstahtrofemehcsgniriwdnastnenopmoceht

).xobralucitrap

motpmyS )s(esuaCelbissoP noituloS

onrowoLmuucav

retlifytriD

tondeggolcylbmessalortnocretaW.pmuphguorhtogotretawgniwolla

enilmuucavnekorbroesooL.snoitcennoc

gniwolladeggolcsevlavkcehcgniwSrehtoehthguorhtnoitcusotpmup

.pmup

.tuonrowsipmuP

.ylppusretawtneiciffusnI

fisretlifyradnocesdnayrotareponaelC.yrassecen

pmupnruT FFO tneverpotyletaidemmiretawgolcnunehT.egamadlanretni

.ylbmessalortnoc

enilmuucavecalperroriaper,nethgiT.snoitcennoc

fi,dnaevlavehtfopotehtffoekaTeht,esiwrehtO.sirbedevomer,elbissop

.decalperebdluohsevlav

.noitcesriaperpmupotrefeR

ehtotstcennoctierehwylppuskcehClortnocretawehtkcehc,nehT.tenibacevlavdioneloslortnocretawehT.evlav

kcehC.nodenrutsipmupehtnehwsneporetawehtgnitcennocsidybnoitcnufsiht

ybdnagnisuohmuucavehtsretnetahtenil,nehT.evlavehtrednureniatnocagnidloh

aebdluohserehT.pmupehtnonrut.retawfomaertsydaets

TONOD:NOITUAC PMUPEHTEVAELsierehtfI!RETAWTUOHTIWGNINNURlortnocretawehtecalper,wolfretawon

.evlavdionelos

Section VII User Service Information

Vacuum Pump (Continued)

Electrical System

Page 30: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 29

21Single Wet Vacuum Pump

motpmyS )s(esuaCelbissoP noituloS

tonpmuPgninnur

foesuacebtcepsus

lacirtcelemelborp

esufnwolbsahylppusrewopniaM.rekaerbtiucricro

ropmupgnihcaertonrewoP.egatlovtcerrocni

.xoblortnocehtniesufnwolB

ehtedisnisnoitcennocesooL.xoblortnoc

.rekaerbtiucricteserroesufnwolbecalpeR

laudehtfoedisehtnoxobnoitcennockcehCpmupehtgnihcaersirewopyfirevottenibac

.egatlovtcerrocehtsiylppusrewopniamdna

detaremasehthtiwesufehtecalpeR.yrotcafehtmorfenoehtsayticapac

yllausivdnarevocxoblortnocehtevomeR.snoitcennocesoolroftcepsni ehtotrefeR(

rofrevocxoblortnocehtedisnicitamehcstahtrofemehcsgniriwdnastnenopmoceht

).xobralucitrap

motpmyS )s(esuaCelbissoP noituloS

onrowoLmuucav

retlifytriD

tondeggolcylbmessalortnocretaW.pmuphguorhtogotretawgniwolla

enilmuucavnekorbroesooL.snoitcennoc

gniwolladeggolcsevlavkcehcgniwSrehtoehthguorhtnoitcusotpmup

.pmup

.tuonrowsipmuP

.ylppusretawtneiciffusnI

fisretlifyradnocesdnayrotareponaelC.yrassecen

pmupnruT FFO tneverpotyletaidemmiretawgolcnunehT.egamadlanretni

.ylbmessalortnoc

enilmuucavecalperroriaper,nethgiT.snoitcennoc

fi,dnaevlavehtfopotehtffoekaTeht,esiwrehtO.sirbedevomer,elbissop

.decalperebdluohsevlav

.noitcesriaperpmupotrefeR

ehtotstcennoctierehwylppuskcehClortnocretawehtkcehc,nehT.tenibacevlavdioneloslortnocretawehT.evlav

kcehC.nodenrutsipmupehtnehwsneporetawehtgnitcennocsidybnoitcnufsiht

ybdnagnisuohmuucavehtsretnetahtenil,nehT.evlavehtrednureniatnocagnidloh

aebdluohserehT.pmupehtnonrut.retawfomaertsydaets

TONOD:NOITUAC PMUPEHTEVAELsierehtfI!RETAWTUOHTIWGNINNURlortnocretawehtecalper,wolfretawon

.evlavdionelos

Section VII User Service Information

Vacuum Pump (Continued)

Electrical System

Wet Vacuum Pumps

TROUBLESHOOTING

Installation, Operation and Care Manual

Single Wet Vacuum Pump

22

115 Volt PumpFuse replacement: Use BUSS MDL or MDQ 3/10 A,Littlefuse 313 3/10 A Slo-blo.

230 Volt PumpFuse replacement: Use BUSS MDL or MDQ 15/100 A,Littlefuse 313 15/100 A Slo-blo.

motpmyS )s(esuaCelbissoP noituloS

seodrotoMybtratston

hctiws

ehtniliocroremrofsnartevitcefeD.yaler

ehtnihsup,ecivedevitcudnoc-nonagnisUlliwrotomehtfienimretedotyalerehtnosbat

,tnempiuqetsetlacirtcelegnisunehT.tratsyradnocesehtfotuognimocegatlovehtyfirev

,V12nahtsselsitifI.remrofsnartehtfoedis,V12nahteromsitifI.remrofsnartehtecalper

.yalerehtecalper

Electrical System (Continued)

Section VII User Service Information

Relay Box

Fuse Replacement

— WARNING —For continued protection against fire

hazard: Correct fuse must be used.

GREEN&YELLOW

LIGHT BLUE

TERMINALBLOCK

(64615023)

RED

BROWN

RELAY(64568133)

TRANSFORMER(64637018)

RED

SPAREFUSE

HOLDER(64561005)

RPL. 115V FUSE (64568131)RPL. 230V FUSE (64568130)

FUSEHOLDER

(64568160)

BLACK(64625083)

BROWN(64625085)

PURPLE(64625073)

YELLOW(64625084)

BROWN&WHITE(65625074)

BLACK(64625077)

BLUE (64625063)

YELLOW(64625082)

TERMINAL BLOCKJUMPER (64615021)

BROWN(64625089)

CIRCUITBREAKER

RPL. 15 AMP BREAKER (3802-120)RPL. 8 AMP BREAKER (3801-911)

6 5 4 3 02 1

RED

PN: 64529265A

WH

ITE

BLUE

BRO

WN

BLAC

K

Page 31: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-30

CV-101FS / CV102FS

SCHEMATICS

WIRING

23Single Wet Vacuum Pump

VacuumFilter

Relief Valve

Intake ManifoldGauge

Pump

Water

Wiring Schematic

Air/Water Flow Circulation Diagram

The Dual Wet Vacuumelectrical control system isa low-voltage (24V) circuit.This system also providesautomatic control of thewater supply system. Thewiring schematic shows forelectrical rough-in. (Refer tothe Installation section ofthis manual.) (See Pages 3and 4 for further informa-tion on rough-in and finalhook-up locations.)

The circulation diagramshows the relationship ofall the major assemblies tothe total system. All con-necting lines are markedwith a symbol to indicatetheir function: vacuum line,water line or waste line.The assemblies are indi-vidually broken down andfurther explained in othersections of this manual.

Section VII User Service Information

.oN .ytQ .oNtraP noitpircseD1 2 53186546 retaW,retliF2 2 65186546 )ylnO(dioneloS,evlaV3 2 11022646 nohpiS-itnA,evlaVA4 2 29186546 PH1--rotalugeRwolF,evlaVB4 2 01022646 PH2--rotalugeRwolF,evlaV

.oN .ytQ .oNtraP noitpircseD5 1 04054546 muucaV,retliF6 1 95186546 feileRmuucaV,relffuM7 1 10022646 feileRmuucaV,evlaV

1

7

23

4

65

Relay

Coil

Switch 24V

Transformer

Primary

Fuse 1Relay 1

OL

L1

G

Relay 2L2G

Motor1

Page 32: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 31

MC-201 FS / MC-202 FS

SCHEMATICS

25Dual Wet Vacuum Pump

Water

Vacuum

Waste

Relief Valve

Intake ManifoldGauge

Exhaust Manifold

Pump1

Pump2

Wiring Schematic

Air/Water Flow Circulation Diagram

The Dual Wet Vacuumelectrical control system isa low-voltage (24V) circuit,designed to provide twototally independent controlsystems for each pumpunit. This system alsoprovides automatic controlof the water supply systemfor each pump. The wiringschematic shows forelectrical rough-in. (Refer tothe Installation section ofthis manual.) (See Pages 3and 4 for further informa-tion on rough-in and finalhook-up locations.)

The circulation diagramshows the relationship ofall the major assemblies tothe total system. All con-necting lines are markedwith a symbol to indicatetheir function: vacuum line,water line or waste line.The assemblies are indi-vidually broken down andfurther explained in othersections of this manual.

Section VII User Service Information

.oN .ytQ .oNtraP noitpircseD

1 2 21022646 ffotuhSretaW,evlaV

2 2 19186546 kcehCgniwS,evlaV3 2 A11022646 nohpiS-itnA,evlaVA4 2 29186546 PH1--rotalugeRwolF,evlaV

B4 2 01022646 PH2--rotalugeRwolF,evlaV

.oN .ytQ .oNtraP noitpircseD

5 2 65186546 )ylnO(dioneloS,evlaV

6 2 53186546 retaW,retliF7 1 95186546 feileRmuucaV,relffuM8 1 10022646 feileRmuucaV,evlaV

17

5

81

2

3

2

43

4

65

6

Relay 1

Relay 2

Solenoid 1

Switch 1

Solenoid 2

Switch 2

24V

24V

Transformer 1

Transformer 2

Primary

Primary

Fuse 1

Fuse 2

Relay 1A

OL

L1

G

Relay 1BL2G

L3

Motor1

Relay 2A

OL

Motor2 G

Relay 2BL4

WIRING

Page 33: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-32

Wet Vacuum Pumps

SCHEMATICS

WIRING

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

8

Section III Installation

IMPORTANT NOTE: If not using a DentalEZ Master Control Panel Kit,proceed as follows:

1. Position the master switch in the desired location.

2. Run the appropriate wires to their respective euipment location. (See wiring chartbelow.)

3. Connect wires according to the wiring diagrams on the next two pages.

Remote Low-Voltage Switch Control

WIRING CHART

— WARNING —Before proceeding with any electrical installation, comply with and

maintain all applicable local electrical code(s) and regulations.

— NOTICE —All wiring between the main control box and equipment should be Class B, low-

voltage. In most cases, a conduit is not required when using this type of wiring.

CV-101 3 18 AWG 16 AWGCV-102 3 18 AWG 16 AWGDV-301 3 18 AWG 16 AWGDV-302 3 18 AWG 16 AWGMC-201 6 18 AWG 16 AWGMC-202 6 18 AWG 16 AWG

Air Compressor 3 18 AWG 16 AWGMWCV Solenoid Valve 2 18 AWG 16 AWGMWCV Transformer 2 18 AWG 16 AWG

Model No. No. of Wires Wire Under 150 ft. Wire Over 150 ft.

Page 34: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 33

MC-201 FS / MC-202 FS

SCHEMATICS

WIRING

9Dual Wet Vacuum Pump

Section III Installation

Two Switch, Dual Vacuum System

IMPORTANT NOTE: Refer to wiring chart on Page 8 for length and gauge of wire.

Wall-Mounted Switches

Shown from Back of

Switch Plate(CustomAir

MP400)

Vacuum 1

Junction Box

Vacuum PumpRelay Box

Brown

YellowBlack

ON/OFF Switches Mounted on Dual Frame

Vacuum 2

Brown

YellowBlack

Line Voltage(To Source)

Load(To Vacuum

Pump)

L1

L2 T2

T1

Vacuum PumpRelay Box

Line Voltage(To Source)

Load(To Vacuum

Pump)

L1

L2 T2

T1

Ret

urn

Ligh

t C

omm

on

Pow

er

Ret

urn

Ligh

t C

omm

on

Pow

er

32

Page 35: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-34

SCHEMATICS

WIRING

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

10

One Switch, Dual Vacuum System

IMPORTANT NOTE: Refer to wiring chart on Page 8 for length and gauge of wire.

L1

L2 T2

T1

Wall-Mounted Switch

Shown from Back of

Switch Plate

Junction Box

Vacuum PumpRelay Box

Brown

YellowBlack

ON/OFF Switches Mounted on Dual Frame

Vacuum

Brown

YellowBlack

Line Voltage(To Source)

Load(To Vacuum

Pump)

L1

L2 T2

T1

Line Voltage(To Source)

Load(To Vacuum

Pump)

Ret

urn

Light Common

Pow

er

Light Common

Vacuum PumpRelay Box

32

Page 36: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 35

CV-101FS / CV102FS

SYSTEM

REPAIR

PROCEDURE

Installation, Operation and Care Manual

Single Wet Vacuum Pump

24

Section VII User Service Information

Tools Required:

• Wire Stripper/Crimper

• 1/4", 5/16", 11/32" and 3/8"Nut Driver

• 7/16", 1/2", 9/16" and 15/16"Open-end Wrench

• 1-3/4" Socket and Torque Wrench

• 15/16" Socket with Ratchet

• Hammer

• Flat-blade Screwdriver

• Wire Cutter

• Needle-nose Pliers

• Channel-lock Pliers

• Paint Scraper

• Pump Motor Holding Fixture:DTE# 64546001

• Pop Riveter

• Bench Vise

• Bearing Seal Lubricant

• Red Loctite/Pipe Sealant:Item# 57141

Dust Cover

If the motor does not start after checking through thetroubleshooting charts, the motor may be defective.If the pump must be removed for factory repair orreplacement, perform the following vacuum pumpsystem repair procedure:

Test Procedure — DiagnosticDetermine if the required repair procedure iselectrical or mechanical.

1. Unplug the electrical supply cord.

2. Using the manual valve, turn OFF the watersupply.

3. Remove the dust cover located at the topcenter of the motor.

Vacuum Pump System Repair Procedure

4. Using a flat-blade screwdriver, engage the slotin the drive shaft and rotate the shaft to checkfor free movement:• If the shaft moves smoothly, proceed to

Electrical Box Removal.• If the shaft is difficult to turn or is jammed,

proceed to Pump Removal/Disassembly.

Electrical Box Removal1. Remove the electrical box cover plate.

— WARNING —Do not attempt these repairs in the dental office.

Fuse

Electrical BoxCover Plate

Drive Shaft Slot

Page 37: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-36

CV-101FS / CV102FS

SYSTEM

REPAIR

PROCEDURE

25Single Wet Vacuum Pump

Section VII User Service Information

5. Remove the water line from the pump housing.

6. Remove the bolt from the bottom of theelectrical box where the bracket is attached.

7. Remove the two screws and nuts from theterminal board located at the top of theelectrical box (old style).

8. Remove the chase nipple from inside the boxwhere it screws to the motor.

Pump Removal/Disassembly1. Remove the motor cover plate (top of motor).

2. Shut OFF the valve supplying water to thepump.

3. Disconnect the vacuum and exhaust lines at thepump and install line closure plugs.

4. Disconnect the two motor wire leads from theelectrical terminal.

Wires

Water Line

Bolt

ChaseNipple

Vacuum Intake

Water Line

2. Check the wire leads to the motor for breaksor bad connections.

3. Check the fuse and check for loose or brokenwires in the electrical box.

4. Disconnect the wires from the top of themotor and pull through the box.

Pump MotorHolding Fixture

5. Disconnect the waste and input lines from thepump and cap off the lines using the closureplugs provided.

6. Disconnect the vacuum intake manifold.

7. Disconnect the water line at the pump.

8. Disconnect the low voltage wires from theremote switch circuit.

9. Mount the motor in the pump motor holdingfixture by aligning the slot in the motor's shaftto the holding blade. Then connect the holddown brackets and tighten so the motor willnot rotate in the fixture.

Two Screws

Page 38: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 37

CV-101FS / CV102FS

SYSTEM

REPAIR

PROCEDURE

Installation, Operation and Care Manual

Single Wet Vacuum Pump

26

2. Press the seal into the housing with theceramic side facing outward.

Ceramic Side

MotorShaft

Seal

3. Carefully install the housing onto the motorshaft.

4. Install the black spring seal with the nylonside in contact with the ceramic washer.

NOTE: Lubrication of shaft will easeinstallation.

5. Apply loctite to the threads of the motor shaft.

6. Screw the impeller onto the shaft with the flatside facing the motor.

7. Torque the impeller to 27 in. lbs.

8. Align the housing so that the electrical boxmounting hole is opposite of the small elbowin back of the pump housing.

Section VII User Service Information

10. Take off the base by removing the bolts thatsecure it to the housing. Then inspect the basefor excessive scoring or side wear.

Pump to Motor Assembly1. Apply lubricating oil to the motor shaft, seal

and housing.

Bolts

Impeller

Housing

12. Remove the housing bolts and take off thehousing by pulling it off the shaft.

13. Remove the water seal spring assembly theninspect the housing for pitting or scoring.

11. Remove the impeller by unscrewingcounterclockwise. Then inspect the impellerfor any pitting or scoring.

Page 39: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-38

CV-101FS / CV102FS

SYSTEM

REPAIR

PROCEDURE

27Single Wet Vacuum Pump

4. Install the bolts and required shims.

5. Tighten and check for free spin of theimpeller by removing the motor from thefixture and rotating the impeller. (For properfit, shims may need to be added or deleted.)

Section VII User Service Information

Shims(Left Side)

Shims(Right Side)

ShimsandBolt

Housing/Impeller Spacing1. To properly space the impeller to the housing,

slide two or three .031" shims between thehousing and the motor at one corner.

2. Slide other shims of various sizes diagonallyacross from the corner in Step 1, until theimpeller is snug with the housing.

3. Remove and add up all the sizes of the shimsused. EXAMPLE: A total of .100" is used,divide that by 2 to obtain .050". Use thisamount minus an additional .005" from 1 HPpumps and .010" from 2 HP for each corner.

NOTE: For further explanation, seeShimming Procedure.

SHIMMING PROCEDURE

A. Insert shims between the motor and thehousing at two opposite mounting legs untilsnug.

B. Remove and add up the total thickness ofthe shims from both sides.

EXAMPLE: Left Side + Right Side Shims Shims

.031 .031+.015 +.031+.015 +.005

.061 .067

.061 + .067 = .128

C. Divide the total by 2 and subtract:.005 for 1 HP motor.010 for 2 HP motor

EXAMPLE: .128 : 2 = .064 .064 .005 = .059

D. Use the best combination of shims for therequired shim dimension.

EXAMPLE: RequiredShim

Dimension .059

E. Install a bolt and equal shim combinationsat all four locations.

Combine Shims.031

+.015+.010+.002.058

Page 40: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 39

CV-101FS / CV102FS

SYSTEM

REPAIR

PROCEDURE

Installation, Operation and Care Manual

Single Wet Vacuum Pump

28

Base

Gasket

Section VII User Service Information

6. Install the base with the gasket by aligning theintake and discharge ports. Then tighten thebolts (do not over tighten).

7. Set the pump upright and insert a screwdriverinto the slot on top of the motor and checkfor free spin and smooth operation of thepump.

Vacuum Pump Operation Testing1. To check for proper operation of the vacuum

pump, connect to an electrical source, waterand waste line.

2. Start the pump, then block the suction side ofthe pump and the vacuum relief valve. Thevacuum level should read between 20-25 in. hg.Shims may need to be added or deleted forproper vacuum reading. (Refer to the Housing/Impeller Spacing Section.)

3. Set the vacuum level by unblocking thevacuum relief valve and adjusting the valve to10-12 in. hg.

4. Operate the pump for approximately onehour continuously.

5. Check for any water leaks, electrical problemsand consistent vacuum level.

(On previous page)

Page 41: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-40

MC-201 FS / MC-202 FS

SYSTEM

REPAIR

PROCEDURE

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

26

Section VII User Service Information

Vacuum Pump System Repair Procedure

Tools Required:

• Wire Stripper/Crimper

• 1/4", 5/16", 11/32" and 3/8"Nut Driver

• 7/16", 1/2", 9/16" and 15/16"Open-end Wrench

• 1-3/4" Socket and Torque Wrench

• 15/16" Socket with Ratchet

• Hammer

• Flat-blade Screwdriver

• Wire Cutter

• Needle-nose Pliers

• Channel-lock Pliers

• Paint Scraper

• Pump Motor Holding Fixture:DTE# 64546001

• Pop Riveter

• Bench Vise

• Bearing Seal Lubricant

• Red Loctite/Pipe Sealant:Item# 57141

Dust Cover

DriveShaftSlot

If the motor does not start after checking through thetroubleshooting charts, the motor may be defective.If the pump must be removed for factory repair orreplacement, perform the following steps:

1. Unplug the electrical supply cord.

2. Using the manual valve, turn OFF the watersupply.

3. Disconnect the water line to the pump beingremoved.

4. Disconnect the waste and input lines from thepump being removed and cap off the linesusing the closure plugs provided.

5. Disconnect the low voltage wires from theremove switch circuit.

6. Remove the wing nuts.

Pump Removal

Test Procedure — DiagnosticDetermine if the required repair procedure iselectrical or mechanical.

1. Disconnect the pump electrical cords fromthe receptacles.

2. At the needle valves, turn OFF the mainwater supply to the cabinet.

3. Remove the dust cover located at the topcenter of the motor.

4. Using a flat-blade screwdriver, engage the slotin the drive shaft and rotate the shaft to checkfor free movement:• If the shaft moves smoothly, proceed to

Electrical Box Removal.• If the shaft is difficult to turn or is jammed,

proceed to Pump Disassembly.

Page 42: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 41

MC-201 FS / MC-202 FS

SYSTEM

REPAIR

PROCEDURE

27Dual Wet Vacuum Pump

3. Check the fuse and check for loose or brokenwires in the electrical box.

4. Disconnect the wires from behind the face-plate of the cabinet and pull through the box.

5. Remove the two water lines from the watermanifold.

Section VII User Service Information

7. Remove the two screws and nuts from theterminal board located at the top of theelectrical box.

8. Remove the chase nipple from inside the boxwhere it screws to the motor.

Pump Disassembly1. Remove the motor cover plate (top of motor).

2. Remove the front plate from the cabinet.

3. Remove the nut from the vacuum relief valve.

4. Disconnect the three electrical box wires fromthe switch located behind the faceplate of thecabinet.

Motor Pump Assembly Removal1. Disconnect the pump's vacuum and exhaust

lines and install line closure plugs.

2. Disconnect the pump's water line.

Wires

Water Line

Water Line

2 Screws andNuts

Bolt

ChaseNipple

Vacuum Intake

HoseClamps

Water LineWing Nuts

Electrical Box RemovalNOTE: Most electrical repairs can be performedwithout removing the pump from the cabinet.

1. Remove the electrical box cover plate.

2. Check the wire leads to the motor for breaksor bad connections.

Fuse

Electrical BoxCover Plate

6. Remove the bolt from the bottom of the boxwhere the bracket is attached.

3. Shut OFF the valve at the water controlmanifold.

4. Remove the wing nuts from the pump's base.(four nuts - 2 HP pump; three nuts - 1 HP pump)

Page 43: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-42

MC-201 FS / MC-202 FS

SYSTEM

REPAIR

PROCEDURE

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

28

Section VII User Service Information

5. Disconnect the two motor wire leads from theelectrical terminal.

8. Remove the impeller by unscrewingcounterclockwise. Then inspect the impellerfor any pitting or scoring.

9. Remove the housing bolts and take off thehousing by pulling it off the shaft.

10. Remove the water seal spring assembly.

11. Inspect the housing for pitting or scoring.

Bolts

Impeller

Housing

Pump MotorHolding Fixture

7. Take off the base by Removing the bolts thatsecure it to the housing. Then inspect the basefor excessive scoring or side wear.

6. Mount the motor in the pump motor holdingfixture (DTE# 64546001) by aligning the slot inthe motor's shaft to the holding blade. Thenconnect the hold down brackets and tightenso the motor will not rotate in the fixture.

Page 44: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 43

SYSTEM

REPAIR

PROCEDURE

MC-201 FS / MC-202 FS

29Dual Wet Vacuum Pump

Pump to Motor Assembly1. Apply lubricating oil to the motor shaft, seal

and housing.

Housing/Impeller Spacing1. To properly space the impeller to the housing,

slide two or three .031" shims between thehousing and the motor at one corner.

Section VII User Service Information

Ceramic Side

MotorShaft

Seal

Shims(Left Side)

Shims(Right Side)

ShimsandBolt

2. Press the seal into the housing with theceramic side facing outward.

3. Carefully install the housing onto the motorshaft.

4. Install the black spring seal with the nylonside in contact with the ceramic washer.

NOTE: Lubrication of the motor shaft willease installation.

5. Apply loctite to the threads of the motorshaft.

6. Screw the impeller onto the shaft with the flatside facing the motor.

7. Torque the impeller to 27 in. lbs.

8. Align the housing so that the small elbow isopposite the electrical box mounting hole inthe motor.

2. Slide other shims of various sizes diagonallyacross from the corner in Step 1, until theimpeller is snug with the housing.

3. Remove and add up all the sizes of the shimsused. EXAMPLE: A total of .100" is used,divide that by 2 to obtain .050". Use thisamount minus an additional .005" from 1 HPpumps and .010" from 2 HP for each corner.

NOTE: For further explanation, seeShimming Procedure.(On next page)

Page 45: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-44

SYSTEM

REPAIR

PROCEDURE

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

30

4. Install the bolts and required shims.

5. Tighten and check for free spin of theimpeller by removing the motor from thefixture and rotating the impeller. (For properfit, shims may need to be added or deleted.)

Base

Gasket

SHIMMING PROCEDURE

A. Insert shims between the motor and thehousing at two opposite mounting legs untilsnug.

B. Remove and add up the total thickness ofthe shims from both sides.

EXAMPLE: Left Side + Right Side Shims Shims

.031 .031+.015 +.031+.015 +.005

.061 .067

.061 + .067 = .128

C. Divide the total by 2 and subtract:.005 for 1 HP motor.010 for 2 HP motor

EXAMPLE: .128 : 2 = .064 .064 .005 = .059

D. Use the best combination of shims for therequired shim dimension.

EXAMPLE: RequiredShim

Dimension .059

E. Install a bolt and equal shim combinationsat all four locations.

Combine Shims.031

+.015+.010+.002.058

Section VII User Service Information

6. Install the base with the gasket by aligning theintake and discharge ports. Then tighten thebolts (do not over tighten).

7. Set the pump upright and insert a screwdriverinto the slot on top of the motor.

8. Check for free spin and smooth operation ofthe pump.

Vacuum Pump Operation Testing1. To check for proper operation of the vacuum

pump, connect to an electrical source, waterand waste line.

2. Start the pump, then block the suction side ofthe pump and the vacuum relief valve. Thevacuum level should read between 20 -25 in hg.Shims may need to be added or deleted forproper vacuum reading. (Refer to the Housing/Impeller Spacing Section.)

3. Operate the pump for approximately onehour continuously.

4. Check for any water leaks, electrical problemsand consistent vacuum level.

(On previous page)

Page 46: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 45

PARTS

LISTS

CV-101FS / CV102FS

5Single Wet Vacuum Pump

Installation Kit

Section III Installation

.oN .ytQ .oNtraP noitpircseD

1 1 50040546 THM4/3xPIM4/3nolyN,rotpadA

2 2 97040546 BRAB4/3xPIM4/3,nolyN,rotpadA

3 1 30140546 knahS1xTPN1,CVP,rotpadA

4 2 40140546 knahS1xTPN4/3CVP,rotpadA

5 1 21061546 PIF8/1xPIM2/1,gnihsuB

6 6 30072546 TSS"1,pmalC

7 2 15033546 PIF4/3xesoHleviwS,gnilpuoC

8 1 28014546 PIF1xpilS1,CVP,woblE

9 1 51114546 knahS1xTPN1,CVP,woblE

01 2 71114546 knahS1xTPN4/3CVP,woblE

11 .tf8 01026546 "1,raelC,esoH

21 1 41077546 "1,tsuahxE,relffuM

31 2 40097546 noisserpmoC4/1,tuN

41 1 93097546 4/1,straPgnibuTnoisserpmoC

51 .tf4 60081646 4/1,nolyNlarutaN,ebuT

61 1 21022646 eldeeN,4/1x8/1,elgnA,evlaV

71 4 20042646 rebbuRkcalB,esoH,rehsaW

Each vacuum pump is supplied with an installation kit (PN: 64568036).

132 4

56

7

8

9 1011

12

13

14

15

1617

Page 47: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-46

PARTS

LISTS

CV-101FS / CV102FS

7Single Wet Vacuum Pump

Section III Installation

The water going to the unit acts as a pump sealantand cooling agent. When the vacuum pump is inoperation, the water supply must be on at all times.There are two methods of installation:

1/8" MIP Angle Valve Installation

The plumber supplies the water line and installs a 1/2"brass gate valve on the water supply line. Connect the1/4" nylon tubing and slide the nut and brass ferruleover the tubing. Push the tubing in the valve as far aspossible. Make sure the tapered end of the ferrule isfacing the end of the tubing and tighten the nut.

1

2

3

4

5

6

.oN .ytQ .oNtraP noitpircseD

1 1 * eniLretaW

2 1 * "2/1,ssarB,etaG,evlaV

3 1 21061546 xPIM"2/1,ssarB,gnihsuBPIF"8/1

4 .tf4 60081646 "4/1,nolyN,ebuT

5 1 93097546 gnibuTsnoisserpmoC"4/1,straP

6 1 21022646 ,"4/1x"8/1,elgnA,evlaVeldeen

* Plumber Supplies

Water Supply Line

Saddle Valve Installation

A saddle valve may be tapped into an existing coldwater line. Follow the instructions on the saddle valvepackage.

1

2

3

4

5

67 8

.oN .ytQ .oNtraP noitpircseD

1 1 * eniLretaW

7-2 1 * ,"4/1,evlaVelddaStiKetelpmoC

8 .tf4 60081646 "4/1,nolyN,ebuT

Angle Valve Installation

Saddle Valve Installation

* Plumber Supplies

Page 48: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 47

PARTS

LISTS

CV-101FS / CV102FS

Installation, Operation and Care Manual

Single Wet Vacuum Pump

8

Section III Installation

Vacuum Line

Vacuum lines must be installed by a local plumberaccording to local building codes. All vacuum linesand risers are recommended to be IPS, PVC, SCH.40. Type “M” copper should be used if local codedoes not allow the use of PVC.

Care should be taken to slope the lines 1" for every20' of run toward the vacuum pump(s). This allowswaste and liquids to flow with gravity, contributing tothe efficiency of the vacuum system.

Make all connections using long radius sweep fittings.To promote unrestricted flow of air and waste liquids

through the vacuum lines, directional flow connec-tions should be used.

Using 45º elbows for turns or avoiding obstructions isbest; however, do not make a trap in the line, doing sowill decrease the efficiency of the system.

All elbows and tees should be sized for the main lineand sized down with bushing reducers to accommo-date smaller lines.

Avoid sagging lines, which cause the formation oftraps in the system and prevent good air and wasteliquid flow.

Connect the evacuation system to the vacuum lineusing the hose and fittings supplied in the installa-tion kit.

1

2

3

4

5

.oN .ytQ .oNtraP noitpircseD

1 * ,CVP,SPI,eniLmuucaV04.HCS

2 1 51114546 "1x"1,woblE

3 1 30140546 "1x"1,CVP,retpadA

4 1 30072546 "1,leetSsselniatS,pmalC

5 .tf4 01026546 "1,ekatnI,esoH

— IMPORTANT —All vacuum systems must be installed accord-

ing to local building and electrical codes.

* Supplied by Plumber

Page 49: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-48

PARTS

LISTS

CV-101FS / CV102FS

9Single Wet Vacuum Pump

Section III Installation

Waste Line

— IMPORTANT NOTE —No part of the waste line should be morethan three (3) feet above the level of thewaste connection on the vacuum pump.

The waste line carries water from the pumps andliquid waste from the operatory to the building'ssewer system.The waste line should follow the most direct path tothe sewer connection with a minimum of bends andelevations, and must be installed according to localbuilding and plumbing codes.The exhaust connection should be made by either oftwo methods, floor sink connection or direct connec-tion to “P” trap, depending on local code and build-ing facilities.

1

2

3

4

Floor Sink Connection

Direct Connection to "P" Trap

12

Use floor sink adapter SA-100. Install as illustrated.

Use “P” trap-air gap, if required by local code. Installas illustrated.

.oN .ytQ .oNtraP noitpircseD

*1 1 ** "1,kniSroolF,CVP,retpadA

*2 1 20140546 "1x.SNI"1,CVP,retpadA

3 1 30072546 "1,leetSsselniatS,pmalC

4 .tf3 01026546 "1,tsuahxE,esoH

5 1 rebmulPseilppuS kniSroolF

.oN .ytQ .oNtraP noitpircseD

1 1 01026546 "1,tsuahxE,esoH

2 1 30072546 "1,leetSsselniatS,pmalC

3 1 * tuN/x"1,ssarB,woblE

4 1 * PIF"1xPIM"1,CVP,gnihsuB

5 1 * "2,paGriA,retpadA

6 1 * ,"2/1-1x"2,lleB,recudeR.vlaG

7 1 * .vlaG,esolCx"2/1-1,elppiN

8 1 * "2/1-1,”P”,parT* Floor Sink Adapter Parts* Supplied by Plumber

1

* Supplied by Plumber

3

4

5

6

7

8

Page 50: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 49

PARTS

LISTS

CV-101FS / CV102FS

Installation, Operation and Care Manual

Single Wet Vacuum Pump

12

1 HP Single Pump Assembly

.oN .ytQ .oNtraP noitpircseD

1 10168546 PH1,caViH

1 1 R05110546 V032,V511,tinUyaleR

2 1 69186546 nollag2/1,dlofinaMretaW

3 1 95057546 SF,PH1,rotoM

4 1 64186546 "2/1x"4/3,ssarB,rotpadA

5* sA.qeR

1004064620040646300406464004064650040646

kcihT500.leetS,mihSkcihT130.leetS,mihSkcihT510.leetS,mihSkcihT200.leetS,mihSkcihT010.leetS,mihS

6* 4 820-5161 "1x61--"8/3,wercSpaC

7* 1 99186546 PH1,ssarB,gnisuoH

8* 1 72186546 rebiF,teksaGgnisuoH

9* 1 32186546 yratoR,laeSgnisuoH

01* 1 89186546 PH1,ssarB,rellepmI

11* 1 86186546 PH1,ssarB,esaB

21* 4 61042646 "61/5,ratSlanretnI,rehsaW

31* 4 44011646 "1x81-"61/5,paC,wercS

31-5* 1 52186546 PH1,tiKdliubeRrewoL

41 1 46186546 eguaG/w,ekatnI,dlofinaMevlaVdna

51 2 40097546 ,ebuT"4/1,tuNnoisserpmoC

61 2 20001646 noisserpmoC,"4/1,eveelS

71 1 55186546 "4/1x"4/1,woblE

81 1 30086546 PH1,tiKteeFgnitnuoM

1 45041546 otxoBlacirtcelE,tekcarBrezilibatS,rotoM

NOTE: See the Operation/Maintenance section ofthis manual for detailed information on hookup andcare of the Single Wet Vacuum Pump.

1

67

18

2

3

5

4

9

10

14

15

8

Section IV Illustrated Parts Breakdown

16

17

11

12

13

Page 51: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-50

PARTS

LISTS

CV-101FS / CV102FS

13Single Wet Vacuum Pump

2 HP Single Pump Assembly

Section IV Illustrated Parts Breakdown

.oN .ytQ .oNtraP noitpircseD

1 20168546 PH2,caViH

1 1 R05110546 V032,tinUyaleR

2 1 79186546 nollag1,dlofinaMretaW

3 1 06057546 SF,PH2,rotoM

4 1 74186546 "2/1x"4/3,ssarB,rotpadA

5* sA.qeR

1004064620040646300406464004064650040646

kcihT500.leetS,mihSkcihT130.leetS,mihSkcihT510.leetS,mihSkcihT200.leetS,mihSkcihT010.leetS,mihS

6* 4 820-5161 "1x61-"8/3,wercSpaC

7* 1 00286546 PH2,ssarB,gnisuoH

8* 1 82186546 rebiF,teksaGgnisuoH

9* 1 42186546 yratoR,laeSgnisuoH

01* 1 98186546 PH2,ssarB,rellepmI

11* 1 86186546 PH2,ssarB,esaB

21* 5 61042646 "61/5,ratSlanretnI,rehsaW

31* 5 44011646 "1x81-"61/5,paC,wercS

31-5* 1 62186546 PH2,tiKtliubeRrewoL

41 1 46186546 eguaG/w,ekatnI,dlofinaMevlaVdna

51 2 40097546 ,ebuT"4/1,tuNnoisserpmoC

61 2 20001646 noisserpmoC,"4/1,eveelS

71 1 55186546 "4/1x"4/1,woblE

81 1 40086546 PH2,tiKteeFgnitnuoM

1 45041546 otxoBlacirtcelE,tekcarBrezilibatS,rotoM

1

6

7

18

2

3

5

4

9

10

14

8

1617

11

12

13

15

Page 52: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 51

PARTS

LISTS

CV-101FS / CV102FS

Installation, Operation and Care Manual

Single Wet Vacuum Pump

14

Electrical Box

Section IV Illustrated Parts Breakdown

*NOTE: Electrical Box Assembly Kits: Part Nos.64501151, 115/230V (1 HP) and PN 64501157,230V (2 HP) are complete with water manifold attached.

1

2

345

15

16

14

18

17

.oN .ytQ .oNtraP noitpircseD

1 05110546 ,ylbmessAxoBlacirtcelEV032roV511

1 1 11031546 sissahCxoBlortnoC2 1 B11031546 revoCxoBlortnoC3 1 72092546 V42,woL,laceD4 1 47192546 gninraWkcohS/eriF,laceD5 1 28192546 margaiD.celEVD,laceD6 1 58192546 kcolBlanimreTVD,laceD7 1 40016546 redloHpilCesuF8 1 33186546 yticapaCPMA03,yaleR9 2 450-3261 "2/1x23-01,wercS01 1 06011646 dnuorG,neerG23-01,wercS11 4 58011646 spillihP"4/1x8,wercS

21 1 91111646 esuF,"61/5x23-6,wercSredloH

31 2 02111646 draoBlanimreT,23-6,wercS41 1 32051646 tcennoC.kQ7,drBlanimreT51 1 620-6361 ratsl'tnI01#,rehsaWkcoL61 1 59186546 V032/511,.snarTyramirP71 1 52092546 stloVwoLnoituaC,laceD81 1 30292546 gninraWegasUeriW,gaT91 2 30062646 yarGB-17,laedI,tuNeriW

1 86081646 kcalB,tiudnoC1 85042646 "8/7,rehsaW2 10087546 "2/1,esahC,elppiN1 37052646 "6,elpruP,.aG81,eriW

* 1 15110546 ,tiKylbmessAxoBlacirtcelE)PH1(V032/511

* 1 75110546 ,tiKylbmessAxoBlacirtcelE)PH2(V032

02 11

021-2083119-1083

roPMA51,rekaerBtiucriCPMA8,rekaerBtiucriC

.oN .ytQ .oNtraP noitpircseD

1 80023546 V032,droC

1

1

68192546

78192546

tnemecalpeResuF,laceDroV511,A01/3

tnemecalpeResuF,laceDV032,A001/51

1

1

52192546

62192546

zH06,A5.7,V032,laceDro)lauDPH1(

zH06,A51,V032,laceD)PH2(

1 794-9762 dnuorG,laceD

1 52013546 kcalB,ni-panS,rotcennoC

1 10097546 "2/1,gnikcoL,tuN

1

1

13186546

03186546

,olB-olS,pmA01/3,esuFro)4fo.gkp(V511

,olB-olS,pmA001/51,esuF)4fo.gkp(V032

2

6 1

7

10

11

8

9

12

13

19

20

Page 53: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-52

PARTS

LISTS

CV-101FS / CV102FS

15Single Wet Vacuum Pump

Water Control Assembly

Section V Repair Parts

The water control system of the CustomAir SingleWet Vacuum Pump provides the pump with the waterflow required for proper suction and supplementalcooling. Automatic and independent water control isprovided for the pump. Filters protect the systemfrom damage because of solid materials in the watersupply. Flow valves control the amount of watersupplied to the pump.

16

7

10

2 3

4 5

8

9

1312

11

14

.oN .ytQ .oNtraP noitpircseD

11

6918654679186546

PH1,.yssAlortnoCretaWPH2,.yssAlortnoCretaW

1 1 40014546 xebuT"4/1,ssarB,woblEPIM"8/1

2 1 53186546 "8/1,retliFretaW

3 1 20087546 PIM"8/1,ssarB,elppiN

4 1 65186546 zh06,v42,evlaVdioneloS

5 1 27040546 xPIM"8/1,ssarB,retpadAPIF"8/1

6 1 60114546 x.pmoC"4/1,ssarB,woblEPIM"8/1

7 1 45186546 thgiartS"6,ebutretaW

8 1 31013546 "8/1xebuT"4/1,rotcennoCPIM

9 1 50061546 ,ssarB,recudeR,gnihsuBPIF"8/1xPIM"8/3

01 1 11022646 "8/3,evlaVnohpys-itnA

11 1 20060646 noisserpmoCTSS,gnirpS

21 129186546

01022646

2/1,evlaVlortnoCwolFroPH1,MPG

,MPG1,evlaVlortnoCwolFPH2

31 1 48014546 xebuT"4/1,ssarB,woblEPIM"8/3

41 RA 80006646 tnalaeS175#,etitcoL*

* All Fittings to be sealed with liquid sealant unless fitting ispretreated from manufacturer with sealant.

Page 54: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 53

PARTS

LISTS

CV-101FS / CV102FS

Installation, Operation and Care Manual

Single Wet Vacuum Pump

16

Anti-Siphon Valve Assembly

Water Solenoid Valve Assembly

.oN .ytQ .oNtraP noitpircseD

1 11022646evlaVnohpiS-itnA

ylbmessA

3,2,1 1 61086546 tiKriapeRnohpiS-itnA

1

2

3

.oN .ytQ .oNtraP noitpircseD

1 38022646evlaVdioneloSretaW

V42,ylbmessA

1 1 88022646 ydoBevlaV

2 1 60020546 V42,ylbmessAnaC&lioC

Section V Repair Parts

A

64568156

Page 55: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-54

PARTS

LISTS

CV-101FS / CV102FS

17Single Wet Vacuum Pump

Section V Repair Parts

Intake Manifold Assembly

Primary / Secondary Filter

ASHCROFT

5

1015

20

25

30 0in.Hgvac

1

6

7

2

3

4

5

8

.oN .ytQ .oNtraP noitpircseD

1 46186546 caViH,yssAdlofinaMekatnI

1 1 88186546 "2,eguaGmuucaV

2 1 10027546 ssarB,dlofinaMekatnI

3 2 95011646 ,wercSpaCdaeHtekcoS"2x02-"4/1

4 1 90048546 ssarB,"8/3,gulP

5 2 30087546 ssarB,esolCx"4/3,elppiN

6 1 10022646 ssarB,evlaVfeileRmuucaV

7 1 73186546 rebiF,teksaGdlofinaM

8 1 95186546 relffuMfeileRmuucaV

.oN .ytQ .oNtraP noitpircseD

1 1 04054546 lwobraelchtiw,"4/3,yramirP,retliF

2 1 91186546 teksaG&neercS

3 1 02186546 teksaG&neercS,lwoB

1

2

3

Page 56: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 55

PARTS

LISTS

MC-201 FS / MC-202 FS

5Dual Wet Vacuum Pump

Section III Installation

Water Supply Line

Vacuum Line

The water going to the unit acts as a pump sealantand cooling agent. When the vacuum pump is inoperation, the water supply must be on at all times.The plumber supplies and installs a 1/2" gate valveon the water supply line. Connect the 3/8" nylontubing and fittings, which are supplied with the unit,as illustrated.

Vacuum lines must be installed by a local plumberaccording to local building codes. All vacuum linesand risers are recommended to be IPS, PVC, SCH.40. Type “M” copper should be used if local codedoes not allow the use of PVC.

Care should be taken to slope the lines 1" for every20' of run toward the vacuum pump(s). This allowswaste and liquids to flow with gravity, contributing tothe efficiency of the vacuum system.

Make all connections using long radius sweep fittings.To promote unrestricted flow of air and waste liquidsthrough the vacuum lines, directional flow connec-tions should be used.

Using 45º elbows for turns or avoiding obstructions isbest; however, do not make a trap in the line, doing sowill decrease the efficiency of the system.

All elbows and tees should be sized for the main lineand sized down with bushing reducers to accommo-date smaller lines.

Avoid sagging lines, which cause the formation oftraps in the system and prevent good air and wasteliquid flow.

Connect the evacuation system to the vacuum lineusing the hose and fittings supplied in the installationkit. The vacuum line can be installed from the right orleft side of the cabinet.

1

23

4

56

7

1

2 3 4

5

.oN .ytQ .oNtraP noitpircseD

1 1 * eniLretaW

2 1 * "2/1,ssarB,etaG,evlaV

3 1 14061546xPIM"2/1,ssarB,gnihsuB

PIF"8/3

4 1 76040546xPIM"8/3,ssarB,retpadA

ebuT"8/3

5 1 70001646,noisserpmoC,eveelS

"8/3,ssarB

6 1 72097546 ebuTnolyN,"8/3,ssarB,tuN

7 .tf4 64081646 "8/3,nolyN,ebuT

* Plumber Supplies

* Plumber Supplies

.oN .ytQ .oNtraP noitpircseD

1 * ,CVP,SPI,eniLmuucaV04.HCS

2 * 04.HCS,CVP,SPI,woblE

3 1 35186546 xPIM"1CVP,retpadAknahS"2/1-1

4 1 40072546 esoH"2/1-1,pmalC

5 .tf6 91026546 "2/1-1,esoH

Page 57: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-56

PARTS

LISTS

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

6

Waste Line

Section III Installation

— IMPORTANT NOTE —No part of the waste line should be morethan three (3) feet above the level of thewaste connection on the vacuum pump.

The waste line carries water and liquid waste from theoperatory to the building's sewer system.The waste line should follow the most direct path tothe sewer connection with a minimum of bends andelevations, and must be installed according to localbuilding and plumbing codes.The waste line can be installed from the right or leftside of the cabinet.The exhaust connection should be made by either oftwo methods, floor sink connection or direct connec-tion to “P” trap, depending on local code and build-ing facilities.

1

23

4

FLOOR SINK CONNECTION

DIRECT CONNECTION TO “P” TRAP

1

2

Electrical Connection Assembly

Use floor sink adapter SA-200, Part No. 6-4504-013.Install as illustrated.

Use “P” trap-air gap, if required by local code. Installas illustrated.

.oN .ytQ .oNtraP noitpircseD

1 1 * "1,kniSroolF,CVP,retpadAtresnIdebraB

2 1 35186546 "2/1-1xPIM"1,CVP,retpadAknahS

3 1 30072546 "2/1-1,leetSsselniatS,pmalC

4 .tf6 91026546 "2/1-1,tsuahxE,esoH

.oN .ytQ .oNtraP noitpircseD

1 .tf6 91026546 "2/1-1,tsuahxE,esoH

2 1 30072546 "2/1-1,leetSsselniatS,pmalC

3 1 * "2/1-1woblE

4 1 * "2/1-1,elppiN

5 1 * "2,paGriA,retpadA

6 1 * "2/1-1x"2,lleB,recudeR

7 1 * esolCx"2/1-1,elppiN

8 1 * "2/1-1,”P”,parT

Complete the electrical hook-up, as the electricalcodes require, through the .375" hole in the boxcover.

.oN .ytQ .oNtraP noitpircseD

1 1 12031546 wercSetalPrevoC

2 1 48448526 xoB-J,etalPrevoC

3 1 06011646 wercSdnuorG

1

2

* Plumber Supplies

Page 58: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 57

PARTS

LISTS

MC-201 FS / MC-202 FS

11Dual Wet Vacuum Pump

Frame Assembly

Section IV Illustrated Parts Breakdown

The various parts of the CustomAir Dual WetVacuum Pump are attached to the frame assembly.The table identifies each assembly and the drawingindicates its location.

.oN .ytQ .oNtraP noitpircseD

1 1 etelpmoc,erusolcnE

2 1 15410546 ylbmessAdlofinaMekatnI

3 11

rolaceD102CMlaceD202CM

4 1 43186546 eguaGmuucaV

5 2 23186546 hctiwSrekcoR

6 1 36186546 ylbmessAdlofinaMretaW

7 4 16186546 tooFCVPlauD

8 6 72011646 "4/1-1,wercSlauD

9 1 26186546 ylbmessAdlofinaMetsaW

01 1 61065546 etihw,"2/1,temmorG

11 1 62031546 tiKnoitallatsnIlacirtcelE

21 1 19310546 ylbmessAlortnoCmuucaV

31 1 94186546 )4fo.gkp(tnuoMrotoM

41 2 71072546 TME"2,regnaH,pmalC

1 2

3

4

5

6

7

8 910

11

12

13

14

8

Page 59: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-58

PARTS

LISTS

MC-201 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

12

1 HP Dual Pump Assembly

Section IV Illustrated Parts Breakdown

The CustomAir Dual Wet Vacuum Pump is poweredby two water injected, impeller type vacuum pumps.This type of vacuum producer runs quietly andgenerates a high mercury pull, which is adjustablefrom a normal operating range of 10 to 12 inches ofmercury to a high range of 18 to 20 inches of mer-cury for surgical applications. There are two vacuumpump sizes: the 1 HP (model MC-201 FS) and the2 HP (model MC-202 FS, illustrated on Page 13). Thedual pump back-up system and the choice of vacuumpower ranges, make this a highly reliable and versatileevacuation system.

.oN .ytQ .oNtraP noitpircseD

1 R10868546 PH1,ylbmessApmuPlauD

1 1 35110546 V032,tinUyaleR

2 1 69186546 nollag2/1,dlofinaMretaW

3 1 80023546 V032,.yssAdroCcirtcelE

4 1 95057546 SF,PH1,rotoM

5 1 55186546 "4/1x"4/1,ssarB,woblE

6 2 34186546 xesoh"1,ssarB,rotpadAPIM"2/1

7 2 93186546 teertS"2/1,ssarB,woblE

8* sA.qeR

1004064620040646300406464004064650040646

kcihT500.leetS,mihSkcihT130.leetS,mihSkcihT510.leetS,mihSkcihT200.leetS,mihSkcihT010.leetS,mihS

9* 1 99186546 PH1,ssarB,gnisuoH

01* 1 32186546 teksag(laeSretaWyratoR)dedulcni

11* 4 820-5161 "1x61--"8/3,wercSpaC

21* 1 89186546 ,decnalaB,ssarB,rellepmIPH1

31* 1 72186546 rebiF,teksaGgnisuoH

41* 1 76186546 PH1,ssarB,etalPesaB

51* 4 61042646 "61/5,rehsaWratSlanretnI

61* 4 44011646 "1x81--"61/5,wercSpaC

61-8* 1 52186546 PH1,tiKdliubeRrewoL

NOTE: See the Operation/Maintenance section ofthis manual for detailed information on hookup andcare of the Dual Wet Vacuum Pump.

1

6

7

11

12

2

3

4

5

910

13

14

15 16

8

58

Page 60: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 59

PARTS

LISTS

MC-202 FS

13Dual Wet Vacuum Pump

2 HP Dual Pump Assembly

Section IV Illustrated Parts Breakdown

.oN .ytQ .oNtraP noitpircseD

1 R20868546 PH2,ylbmessApmuPlauD

1 1 85110546 V032,tinUyaleR

2 1 79186546 nollaG1,dlofinaMretaW

3 1 80023546 V032,.yssAdroCcirtcelE

4 1 06057546 SF,PH2,rotoM

5 1 55186546 "4/1x"4/1,ssarB,woblE

6 2 78040546 xesoh"1,ssarB,rotpadAPIM"4/3

7 2 44186546 teertS"4/3,ssarB,woblE

*8 sA.qeR

1004064620040646300406464004064650040646

kcihT500.leetS,mihSkcihT130.leetS,mihSkcihT510.leetS,mihSkcihT200.leetS,mihSkcihT010.leetS,mihS

*9 1 00286546 PH2,ssarB,gnisuoH

* 01 1 42186546 teksag(laeSretaWyratoRdedulcni

* 11 4 820-5161 "1x61--"8/3,wercSpaC

* 21 1 98186546 ,decnalaB,ssarB,rellepmIPH2

* 31 1 82186546 rebiF,teksaGgnisuoH

* 41 1 86186546 PH2,ssarBetalPesaB

* 51 5 61042646 "61/5,rehsaWratSlanretnI

* 61 5 44011646 "1x81--"61/5,wercSpaC

61-8* 1 62186546 PH2,tiKdliubeRrewoL

1

6

7

10 11

2

3

4

5 8

9

1213

15 16

14

Page 61: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-60

PARTS

LISTS

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

14

Intake Manifold Assembly, Dual

Section IV Illustrated Parts Breakdown

The intake manifold swing-check valves provideautomatic isolation for the back-up pump when it isnot operating. This prevents vacuum loss through theexhaust of the standby pump. When both pumps areoperating, the swing-check valves open to allowmaximum air flow. The manifold is constructed ofPVC and the valves are brass. Both materials are notaffected by chemical disinfectants.

.oN .ytQ .oNtraP noitpircseD

1 15410546 ylbmessAdlofinaMekatnI

1 3 71114546 knahS"1xTPN"4/3,woblE

2 2 1918654639186546

"4/3,evlaVkcehCgniwS"1,evlaVkcehCgniwS

3 3 60061546 xpilS"1recudeR,gnihsuBPIF"4/3

4 1 60073546 pilS"1CVP,ssorC

5 1 40014546 "8/1xebuT"4/1,ssarB,woblEPIM

6 3 24186546 esolC"4/3,ssarB,elppiN

7 1 89087546 gnoL"2x"1,CVP

8 1 80061646 pilS"1,eeT

9 1 79087546 gnoL"4x"1,CVP

01 2 92040546 pilS"1xPIF"1,CVP,rotpadA

11 1 69087546 gnoL"21x"1,CVP

1

67

2

11

4

5

8

To Left Pump

Intake

To Right Pump

To Gauge Assembly

To Vacuum Relief

10

3

9

Page 62: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 61

PARTS

LISTS

MC-201 FS / MC-202 FS

15Dual Wet Vacuum Pump

Exhaust Manifold Assembly, Dual

Section IV Illustrated Parts Breakdown

The exhaust manifold delivers liquid waste materialsfrom both pumps to the drain line. The manifold isconstructed of PVC to prevent chemical corrosionand buildup of organic and mineral wastes. Theexhaust muffler connected to the drain line outsidethe cabinet assures quiet operation.

4

56

7

8

1

2

3

.oN .ytQ .oNtraP noitpircseD

4 1 22110546 tsuahxErotalucriceRretaW)lanoitpO(ylbmessAdlofinaM

5 1 13061546 "2/1-1,recudeRgnihsuBPIF"1xPILS

6 2 43114546 TPN"1,ssarB,woblE

7 2 12114546 PIM"8/1xyloP"4/1,woblE

8 2 12140546 esoH"1,rotpadA

.oN .ytQ .oNtraP noitpircseD

1 1 26186546 .yssAdlofinaMtsuahxE.dtS

2 2 43114546 "1xPIM"1,ssarB,woblEknahS

3 1 42048546 PIM"2/1-1,CVP,gulP

Water Recirculator Exhaust Manifold Assembly (Optional)

Page 63: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-62

PARTS

LISTS

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

16

Electrical Box

Section IV Illustrated Parts Breakdown

*NOTE: Electrical Box Assembly Kits: PN 64501153,230V (1 HP) and PN 64501158, 230V (2 HP) arecomplete with water manifold attached.

.oN .ytQ .oNtraP noitpircseD

1 05110546 ,ylbmessAxoBlacirtcelEV032roV511

1 1 11031546 sissahCxoBlortnoC2 1 B11031546 revoCxoBlortnoC3 1 72092546 V42,woL,laceD4 1 47192546 gninraWkcohS/eriF,laceD5 1 28192546 margaiD.celEVD,laceD6 1 58192546 kcolBlanimreTVD,laceD7 1 40016546 redloHpilCesuF8 1 33186546 yticapaCPMA03,yaleR9 2 450-3261 "2/1x23-01,wercS01 1 06011646 dnuorG,neerG23-01,wercS11 4 58011646 spillihP"4/1x8,wercS

21 1 91111646 esuF,"61/5x23-6,wercSredloH

31 2 02111646 draoBlanimreT,23-6,wercS

41 1 32051646 kiuQ7,draoBlanimreTtcennoC

51 1 620-6361 ratsl'tnI01#,rehsaWkcoL

61 1 59186546 ,remrofsnarTyramirPV032/511

71 1 52092546 stloVwoLnoituaC,laceD81 1 30292546 gninraWegasUeriW,gaT91 2 30062646 yarGB-17,laedI,tuNeriW

1 86081646 kcalB,tiudnoC1 85042646 "8/7,rehsaW2 10087546 "2/1,esahC,elppiN

* 1 35110546 ,tiKylbmessAxoBlacirtcelE)PH1(V032/511

* 1 85110546 ,tiKylbmessAxoBlacirtcelE)PH2(V032

02 1 021-2083 pmA51rekaerBtiucriC02 1 119-1083 pmA8,rekaerBtiucriC

.oN .ytQ .oNtraP noitpircseD

1 80023546 V032,droC

1

1

68192546

78192546

tnemecalpeResuF,laceDroV511,A01/3

tnemecalpeResuF,laceDV032,A001/51

1 794-9762 dnuorG,laceD

1

1

52192546

62192546

zH06,A5.7,V032,laceDro)lauDPH1(

zH06,A51,V032,laceD)PH2(

1 52013546 kcalB,ni-panS,rotcennoC

1 10097546 "2/1,gnikcoL,tuN

1

1

13186546

03186546

,olB-olS,pmA01/3,esuFro)4fo.gkp(V511

,olB-olS,pmA001/51,esuF)4fo.gkp(V032

2

45

2

1

3

15

16

14

18

17

6 1

7

10

11

8

9

12

13

19

20

Page 64: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 63

PARTS

LISTS

MC-201 FS / MC-202 FS

17Dual Wet Vacuum Pump

Water Control Assembly

Section V Repair Parts

The water control system of the CustomAir Dual WetVacuum Pump provides the pumps with the waterflow required for proper suction and sopplementalcooling. Automatic and independent water control isprovided for each pump. Filters protect the systemfrom damage due to solid materials in the watersupply. Flow valves control the amount of watersupplied to each pump.

1

6

7

10

2 3

4 5

8

913

12

11

14

15

.oN .ytQ .oNtraP noitpircseD

11

6918654679186546

PH1,.yssAlortnoCretaWPH2,.yssAlortnoCretaW

1 1 40014546 xebuT"4/1,ssarB,woblEPIM"8/1

2 1 53186546 "8/1,retliFretaW

3 1 20087546 PIM"8/1,ssarB,elppiN

4 1 65186546 evlaVdioneloS

5 1 27040546 xPIM"8/1,ssarB,retpadAPIF"8/1

6 1 60114546 x.pmoC"4/1,ssarB,woblEPIM"8/1

7 1 45186546 thgiartS"6,ebutretaW

8 1 31013546 "8/1xebuT"4/1,rotcennoCPIM

9 1 50061546 ,ssarB,recudeR,gnihsuBPIF"8/1xPIM"8/3

01 1 11022646 "8/3,evlaVnohpys-itnA

11 129186546

01022646

2/1,evlaVlortnoCwolFroPH1,MPG

,MPG1,evlaVlortnoCwolFPH2

21 1 40114546 xebuT"4/1,ssarB,woblEPIM"8/3

31 2 11322646 TPNF"8/3,evlaVkcehC

41 1 19040546 rotpadA

51 1 60081646 "4/1,ebuT

Page 65: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Technical Manual

Section IV Vacuum PumpsPage iv-64

PARTS

LISTS

MC-201 FS / MC-202 FS

Installation, Operation and Care Manual

Dual Wet Vacuum Pump

18

Vacuum Control Assembly

Section V Repair Parts

The vacuum control assembly is attached to thecentral section of the front control panel. The valvein this assembly provides automatic regulation of thevacuum flow in the system. The vacuum level can beadjusted for different system requirements. The vacuumgauge is connected to a fitting on this assembly.

.oN .ytQ .oNtraP noitpircseD1 19310546 ylbmessAlortnoCmuucaV

1 1 71114546 "1xPIM"4/3,CVP,woblEknahS

2 1 10022646 evlaVfeileRmuucaV3 2 61014546 "4/3teertS,ssarB,woblE

4 1 80061546 xpilS"4/1-1,CVP,gnihsuBPIF"4/3

5 1 54186546 feileRmuucaV,tnemelEretliFevlaV

6 1 58011646 spillihP"4/1x8,wercS7 1 90012546 "4/1-1,CVP,paC

Vacuum Gauge and Adapter

In-Line Filter Assembly, 1"

.oN .ytQ .oNtraP noitpircseD1 1 43186546 ylbmessAeguaGmuucaV

*2 1 80013546 yloP"4/1xPIF"4/1,retpadA

NOTE: *Not included in assembly.

.oN .ytQ .oNtraP noitpircseD1 04910546 "1,ylbmessAretliFenIL-nI

1 1 71090546 "1,ydoBretliFeniL-nI

2 1 12186546 D"4/1-2,hseM02,"1,neercSteksaG&,L"4/1-4x

3 1 22186546D"4/1-2,hseM02,"1,neercS"1,lwoB&teksaG,L"4/1-4x

raelC,retliFeniL-nI4 1 14041546 redlo,retliFeniL-nI"1,tekcarB

52

2

35186546

30140546

"2/1-1xPIM"1CVP,retpadAroknahS

"1xPIM"1CVP,retpadAknahS

6 1 24041546 llaWretliFeniL-nI,tekcarBtnuoM

7 3 70011646 tolSnaP"2/1x01,wercS

1

6

7

2

3

45

12

1

5

62

3

4

7

Page 66: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

Section IV Vacuum Pumps

Technical Manual

iv-Page 65

PARTS

LISTS

MC-201 FS / MC-202 FS

19Dual Wet Vacuum Pump

Anti-Siphon Valve Assembly

Water Solenoid Valve Assembly

Section V Repair Parts

.oN .ytQ .oNtraP noitpircseD

1 11022646evlaVnohpiS-itnA

ylbmessA

3,2,1 1 61086546 tiKriapeRnohpiS-itnA

1

2

3

.oN .ytQ .oNtraP noitpircseD

1 65186546evlaVdioneloSretaW

ylbmessA

A

Page 67: DentalEZ MAKES YOUR PRACTICE PERFECTc1-preview.prosites.com/106982/wy/docs/Custom Air MC-201 Techn… · Technical Manual iv-Page 3 C E R T I F I C A T I O N S Vacuum Pumps Installation,

2500 Highway 31 SouthBay Minette, Alabama 36507

1-866-DTE-INFOFax: (251) 937-0461www.dentalez.com

© DentalEZ Alabama, Inc.Printed in USAJanuary, 2010