dc fittings location & identification
DESCRIPTION
DC FITTINGS LOCATION & IDENTIFICATION. LT 3.1. DESCRIBE the purpose, function, types, and locations of DC Compartment Check Off Lists (CCOLs) DESCRIBE how to identify compartments & DC fittings by using DC numbering system. EXPLAIN how to number a new DC fitting using the DC numbering system - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/1.jpg)
1
DC FITTINGS DC FITTINGS LOCATION & LOCATION & IDENTIFICATIONIDENTIFICATION
LT 3.1
![Page 2: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/2.jpg)
2
ENABLING OBJECTIVES
• DESCRIBE the purpose, function, types, and locations of DC Compartment Check Off Lists (CCOLs)
• DESCRIBE how to identify compartments & DC fittings by using DC numbering system
• EXPLAIN how to number a new DC fitting using the DC numbering system
• DESCRIBE the information available in the ship’s DC book and diagrams
![Page 3: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/3.jpg)
3
TEN COMMANDMENTS OF DAMAGE CONTROL
Keep your ship watertightDo not violate material conditionHave confidence in your ship’s ability to withstand severe
damageKnow your way around -- even in the dark!Know how to use & maintain damage control
equipmentReport damage to the nearest Repair Locker
![Page 4: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/4.jpg)
4
Keep personal articles properly securedPractice personal damage control. Protect yourself so you
can protect your ship!Take every possible step to save the ship as long as a bit
of hope remains.Keep cool; don’t give up the ship!
TEN COMMANDMENTS OF DAMAGE CONTROL
![Page 5: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/5.jpg)
5
DAMAGE CONTROL FITTINGS
• All crewmembers must be able to operate key damage control equipment & fittings to control/stop damage
• To do this, everyone must have clear understanding of shipboard compartment & DC fitting numbering
![Page 6: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/6.jpg)
6
![Page 7: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/7.jpg)
7
![Page 8: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/8.jpg)
8
![Page 9: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/9.jpg)
9
![Page 10: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/10.jpg)
10
![Page 11: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/11.jpg)
11
![Page 12: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/12.jpg)
12
![Page 13: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/13.jpg)
13
5-300-0-E
5-260-0-E
3-260-0-A
5-220-0-E
5-174-0-E
1-300-1-L2-260-1-Q
1.5-336-5-T
02-220-0-C
01-220-1-L 01-190-0-Q
03-174-1-Q
02-292-0-Q
1-260-01-L 1-220-0-L 1-174-0-L
Compartment NumberingThe Finished Product
![Page 14: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/14.jpg)
145- - -
3- - -
5- - -
5- - -
2- - -
. 02- - -
01- - - 01- - -
03- - -
1- - - 1- - - 1- - -
Compartment NumberingDeck Number
Numbered by the lowest deck within the space.
O4 LevelO3 Level
O2 Level
O1 Level
Main Deck
2nd Deck
3rd Deck
4th Deck
![Page 15: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/15.jpg)
15
DEFINITIONS
• DC DECK:– Uppermost deck
through which transverse watertight bulkheads extend
– Lowest deck providing fore and aft access
• MAIN DECK:– Uppermost
continuous deck– CV’s:
• Hangar deck
![Page 16: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/16.jpg)
16
MAIN DECK
SECOND DECKTHIRD DECK1st PLAT
010203
![Page 17: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/17.jpg)
17
1 1/2
1/2
01 1/2
HALF DECK NUMBERING
1
23
![Page 18: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/18.jpg)
18PLATFORM
PLATFORM: A LEVEL BELOW THE LOWESTCONTINUOUS DECK
![Page 19: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/19.jpg)
19
5-300- -
5-260- -
3-260- -
5-220- -
5-174- -
1-300- -2-260- -
1.5-336- -
02-220- -
01-220- - 01-190- -
03-174- -
02-292- -
1-260- - 1-220- - 1-174- -
Compartment NumberingFrame Number
Numbered by the foremost frame within the space.
174336 300292 260
220 190
![Page 20: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/20.jpg)
20
• FRAME SPACING:– Arbitrary unit of measurement denoting the
distance between frames– NotNot necessarily the distance between
structural frames.– USS BLUE RIDGE framing if 4 ft apart
DEFINITIONS
![Page 21: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/21.jpg)
21
• FORWARD/AFT PERPENDICULARS:
DEFINITIONS
Most forward and aft points where the design waterline intersects the hull
![Page 22: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/22.jpg)
22
Design Waterline
FORWARD
0 PERPENDICULAR
AFTER
![Page 23: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/23.jpg)
23
DESIGN WATERLINE
FORWARDPERPENDICULAR
AFTPERP.
0B 4 8 16 20 28 60
84AA BB CCAC
![Page 24: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/24.jpg)
24
5-300-0-
5-260-0-
3-260-0-
5-220-0-
5-174-0-
1-300-1-2-260-1-
1.5-336-5-
02-220-0-
01-220-1- 01-190-0-
03-174-1-
02-292-0-
1-220-0- 1-174-0-
Compartment NumberingPosition in relationship to the centerline.
Zero for on the centerline, Even for port side, Odd for starboard.
![Page 25: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/25.jpg)
25
3-20-2-E
3-20-0-E
3-20-1-E2-100-3-L
2-100-1-L
2-100-2-L
2-100-4-L
RELATION TO CENTERLINE
CENTERLINE
![Page 26: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/26.jpg)
26
5-300-0-
5-260-0-
3-260-0-
5-220-0-
5-174-0-
1-300-1-2-260-1-
1.5-336-5-
02-220-0-
01-220-1- 01-190-0-
03-174-1-
02-292-0-
1-260-01- 1-220-0- 1-174-0-
Compartment NumberingPosition in relationship to the centerline.
Zero for on the centerline, Even for port side, Odd for starboard.
![Page 27: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/27.jpg)
27
FRAME 260
CL
1-260-0-L
1-260-01-
1-260-01-L
![Page 28: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/28.jpg)
28
5-300-0-E
5-260-0-E
3-260-0-A
5-220-0-E
5-174-0-E
1-300-1-L2-260-1-Q
1.5-336-5-T
02-220-0-C
01-220-1-L 01-190-0-Q
03-174-1-Q
02-292-0-Q
1-260-01-L 1-220-0-L 1-174-0-L
Compartment NumberingSpace Use Identifier
Listed in NSTM 079 (V2) p.12
![Page 29: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/29.jpg)
29
COMPARTMENT USEA - STOWAGE
AA - CARGO HOLDSC - VITAL SHIP/
FIRE CONTROLE - ENGINEERINGF - FUELG - GASOLINEK - CHEMICALS
L - LIVING SPACESM - AMMUNITIONQ - MISCELLANEOUST - VERTICAL TRUNKV - VOIDW - WATER/SEWAGE
![Page 30: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/30.jpg)
30
BULLSEYES
• Painted on each bulkhead of each compartment• Should be readily visible when entering space• Photoluminescent paint
– Except on weatherdecks• Should not be hidden behind
– Doors– File cabinets
![Page 31: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/31.jpg)
31
5 - 300 - 0 - E
FR 300 - 346
M- DIV
Compartment Identification
"Bull's Eye"
![Page 32: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/32.jpg)
32
5 - 300 - 0 - E
FR 300 - 346
M- DIV
Compartment Identification
"Bull's Eye"
![Page 33: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/33.jpg)
33
• List numbers of access fitting• Compartments on both sides• Name of compartment accessed• Located on bulkhead above access• Can be located adjacent to access if
not enough room– Side away from hinges
Compartment Designation Plate
![Page 34: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/34.jpg)
34
1 - 300 - 1 - L
5 - 300 - 0 - E
WTD 1 - 301 - 1
Compartment Identification
Compartment Designation Plate
![Page 35: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/35.jpg)
35
• Installed in compartments over 24 feet in length
• Installed every 24 feet of length on weatherdecks & hangar deck
• Transverse bulkhead label plate is installed in compt. having tightness requirement only if bhd can’t be ID’d by other means (i.e. access plate)
Frame and Bulkhead Label Plate
![Page 36: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/36.jpg)
36Compartment Identification
FR 346Frame and Bulkhead Label Plate
![Page 37: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/37.jpg)
37
• Train repair party and duty and watch personnel in locating and operating DC fittings
• Marking factors:– Dissemination of reports– Ability of personnel to locate quickly
designated fittings/equip.– Action of personnel in operating dc
equipment & fittings
MOB-D-23-SF “LOCATING DC FITTINGS”
![Page 38: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/38.jpg)
38
DC FITTING NUMBERING
• Similar to compartment numbering without fourth digit
• More than one fitting with same number
• Clarified by type of valve or by system
• Deck & frame designation are closest below & forward
• Relationship to centerline is by system. There may/may not be a “centerline valve”
![Page 39: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/39.jpg)
39
FMCOV 2-121-1SYSTEM DECK FRAME
FIRST VALVE AT FRAME TO STBD
DC FITTING NUMBERING
![Page 40: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/40.jpg)
40
FITTING NUMBER EXERCISE
A new cutout valve in the firemain system is added. Valve is located in the fire room compartment 8-110-0-e. It is on the lower level near the aft bulkhead. The aft bulkhead is 20 feet away from the forward bulkhead. Frame spacing is 30 inches. It is is now the 5th firemain valve in the system from the centerline valve to the port. What is the DC number of this valve?
![Page 41: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/41.jpg)
41
1. IDENTIFY SYSTEM.
2. FIREMAIN COV
FM COV
3. WHERE IS IT LOCATED?4. 8-110-0-E
8 -
5. IDENTIFY WHERE THE SYSTEM IS LOCATED IN SPACE.
6. 20 FEET FROM FWD BHD. FRAME SPACING IS 30 INCHES. 20FT X 12IN = 240 INCHES DIVIDED BY 30 INCHES = 8 FRAMES 110 + 8 = 118.
118 -
7. 5TH VALVE TO PORT OF CL. 2, 4, 6, 8, 10
10
![Page 42: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/42.jpg)
42
COMPARTMENT CHECK OFF LISTS (CCOL’S)
• Required for every compartment or weatherdeck where DC facilities are located
• Permanently posted near each access opening or area
• Itemized list showing location of all classified fittings & other facilities useful for DC
• Posted for the ready use of personnel responsible for setting material conditions of readiness
![Page 43: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/43.jpg)
43
• Prepared & supplied by shipbuilder• Ship’s force required to keep them current• DCA must:
– Maintain master CCOL hard copy file– Maintain backup disk when CCOL is
computerized– Approve all changes to CCOL
• Pen & ink changes not authorized when CCOL is computerized
COMPARTMENT CHECK OFF LISTS (CCOL’S)
![Page 44: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/44.jpg)
44
Master– Kept by DCA– One original copy
of all CCOLs– Stamped
Individual– One entrance to
space
Duplicate– More than one
entrance– Stamped
Partial– Alcoves– Shows only DC
fittings in area– Stamped
COMPARTMENT CHECK OFF LISTS (CCOL’S)
![Page 45: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/45.jpg)
45
AVAILABLE REFERENCES
• DCA– DC BOOK– DC DIAGRAMS– RPM– MASTER CCOL’S
• ON SCENE LEADER– CCOL’S– KNOWLEDGE OF AREA
• REPAIR PARTY LEADER/REPAIR PARTY OFFICER– SHIP’S DC BOOK– SHIP’S DC DIAGRAMS– REPAIR PARTY
MANUAL/REPAIR PARTY LEADER NOTEBOOK
![Page 46: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/46.jpg)
46
Compartment Numbering and Identification
Damage Control Fitting Numbering and Identification
Available References
Compartment Checkoff Lists
SUMMARY AND REVIEW
![Page 47: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/47.jpg)
47
QUESTION #1
• One frame label plate shall be installed in compartments over how many feet in fore-aft length?
• Answer• 24 Feet
![Page 48: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/48.jpg)
48
• What are the four types of CCOLs?
• Answer• Master• Partial• Individual• Duplicate
QUESTION #2
![Page 49: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/49.jpg)
49
• True or False– All bullseyes on the
ship must be painted in photo-luminescent paint.
• Answer• False
QUESTION #3
![Page 50: DC FITTINGS LOCATION & IDENTIFICATION](https://reader035.vdocuments.us/reader035/viewer/2022062411/56816846550346895dde22cb/html5/thumbnails/50.jpg)
50
THE END